Range 16A to 63A. Sensitivity 30mA, 100mA, 300mA, 500mA. Execution Double Pole, Four Pole. Specification IEC / IS : 2000
|
|
- Jane Scott
- 6 years ago
- Views:
Transcription
1 The flow of current through electrical facilities always involves risks. Poorly insulated equipment, faulty wires and incorrect use of an electrical devise cause currents to flow through the wrong path (i.e., through the insulation) to the earth. This current is called Leakage Current. Earth Leakage is an electrical hazard and is responsible for electrical shocks and fire risk. Earth Leakage and its associated hazard can be prevented by residual current circuit breaker (RCCB), also popularly known as Earth Leakage Circuit Breaker (ELCB). Range 16A to 63A Sensitivity 30mA, 100mA, 300mA, 500mA Execution Double Pole, Four Pole Specification IEC / IS : 2000 Features Simple and Robust operating mechanism. Rotary handle with ON/Off indication Dual termination for Bus Bar as well as cable connection Advance Neautral Test Button for regular inspection 34
2 35
3 PROTECTION AGAINST ELECTROCUTION The use of exposed, substandard, badly wired, wrongly connected or damaged equipment as well as frayed or badly repaired cables reduces the safety of an installation and inreases the risk of person receiving an electric shock. Electrocution is a passage of current through human body, which is dangerous. The flow of current through human body effects vital functions. 1. Breathing 2. Heartbeat A correctly chosen RCCB can detect small currents flowing to earth and reduces the risk of electrocution. Effect of electric current through human body has been well researched and following chart summarizes the results: Effect of electric current through human body has been well researched and following chart summarizes the results: 500 ma Immediate cardiac arrest resulting in death ma Cardiac fibrillation; the heart begins to vibrate and no longer beats at a steady rate. This situation is dangerous since it is irreversible ma Muscle contraction can cause respiratory paralysis 10 ma Muscle contraction : the person remains stuck to the conductor 1-10 ma Prickling sensations 36 However, electrocution should not be viewed in terms of current alone but in terms of contact voltage. A person gets electrocuted by coming in contact with an object that has a different potential from his/her own. The difference in potential causes the current to flow through the body. The human body has known limits: - Under normal dry conditions, voltage limit = 50V - In damp surroundings, voltage limit = 25V AGAINST INDIRECT CONTACT Over current protection devices like MCB are unable to act promptly on small earth leakage currents. To comply with wiring regulations the earth fault loop impedance in Ohms, multiplied by the rate tripping current of the RCD in amperes must not exceed 50. Example For an RCD with a rated tripping current of 30mA, the maximum permissible earth fault loop impedance is calculated as follows: Zs (max) = 50 / In = 50/0.03 = 1,666 Rated tripping current of the RCD 10mA 5,000 30mA 1, mA mA 166 Maximum permissible earth fault loop impedance in AGAINST FIRE The majority of fires which occur as a result of faulty wiring are started by current flowing to earth. Fire can be started by fault current of less than 1 amp. The normal domestic overload protective device such as a fuse or MCB will not detect such a small current. A correctly chosen RCD will detect this fault current and interrupt the supply, hence reducing the risk of a fire starting.
4 TECHNICAL INFORMATION TWO POLE FOUR POLE Standard Conformity IS : 2000, IEC IS : 2000 IEC Rated Current (In) A 16, 25, 32, 40, 63 25, 40, 63 Sensitivity (I n) ma 30, 100, 300, , 100, 300, 500 Rated Voltage (Un) Vac / 415 Rated Insulation Voltage (Ui) V Rated Frequency Hz Shortcircuit Withstand Capacity ka 6 6 Residual Making Breaking Capacity A 10 In 10 In Ambient Temperature o C -25 to to +40 Shock Resistance g Vibration Resistance g 3 3 Electrical Endurance/Mechanical operations Mounting Din Rail (35 x 7.5) mm Din Rail (35 x 7.5) mm Degree of Protection IP 20 IP 20 Terminal Capacity (max) mm WORKING PRINCIPLE The RCCB works on the current balance principle. The supply conductors, i.e., the phases and the neutral, are passed through a torroid and form the primary windings of a current transformer. Its secondary winding is connected to a highly sensitive electromagnetic trip relay, which operates the trip mechanism. In a healthy circuit, sum of the currents in phases, is equal to the current in the neutral and the vector sum of all currents is equal to zero. If there is any insulation fault in the current and leakage current flows to earth, the currents do not balance and their vector sum is not equal to zero. This imbalance is detected by the core balanced current transformer, the RCCB is tripped and supply to load is interrupted. The trip mechanism is operated at a residual current between % of its rated tripping current.
5 SELECTION 30 ma A 30 ma ELCB will provide a high degree of protection against electrocution in a accidental shock hazard situation. The current flowing throgh human body could be between 80mA and 240mA depending on the resistance of the human body and the voltage across it. 38 Zone Zone 1 Zone 2 Zone 3 Zone 4 Physiological Effects Usually no reaction effects Usually no harmful physiological effects Usaully no organic damage to be expected. Likelihood of muscular contraction and difficulty in breathing, reversible disturbances of formation and conduction of impulse in the heart and transient cardiac arrest without ventricular fibrillation increases with current magnitude and time. In addition to the effects of Zone 3, probability if ventricular fabriliation increased upto 5% (curve C 2 ) upto 50% (curve C 3 ) and above 50% beyond curve C3. It increases with magnitude and time, and pathophysiological effects such as cardiac arrest, breathing arrest and heavy burns may occur. To be within zone of the IEC curve as shown above. It is necessary for the ELCB to operate within 50ms at 240 ma and 150ms at 80mA. Both these conditions are satisfied by 30mA ELCB For households, Individual outlets, Wet areas and temperary installations, ELCB with sensitivity not exceeding 30mA is advisable 100 ma A 100mA ELCB will normally give high degree of protection against electrocution but there is a possibility that the shock current could fall below the tripping level of ELCB. This could occur if additional resistances to that of human body are included in the earth path. The 100mA RCCB protects against leakage currents and indirect contact with earth loop impedance upto 500 Ohms. 300 / 500mA A 300/500 ma ELCB may be used where only fire protection is required. eg., on lighting circuits, where the risk of electric shock is small. 300/500mA ELCB will not give any protection against electrocution.
6 ACTUATION TIME CHARACTERISTICS WIRING DIAGRAM 39 For Single Phase - 2 Wire connections For Three Phase - 4 Wire connections For Three Phase - 3 Wire connections The Havell s range of four pole RCBs can be used to provide residual current protection in 3 phase, 3 wire circuits (no neutral), however a link from the neutral to an incoming should be made on the supply side of the RCCB, to enable the operation of the RCCB.
7 DIMENSIONS (IN MM) 2 POLE 4 POLE 40
8 DOUBLE POLE Current Sensitivity Cat No. rating (A) ma RVD RVD RVD RVD RVD RVD RVD RVD RVD RVD RVD RVD RVD RVD RVD30063 FOUR POLE Current Sensitivity Cat No. rating (A) ma RRCF RRCF RRCF RRCF RRCF RRCF RRCF RRCF RRCF
9 Range 80A to 125A Sensitivity 30mA, 100mA, 300mA, 500mA Execution Double Pole Four Pole Specification IEC / IS : 2000 Features Short circuit breaking withstand capacity capacity 10kA Different knob position to indicate whether it is switched off by a fault or manually Test button for regular inspection Very low watt loss 42
10 (80A - 125A RCCB) 43
11 (80A - 125A RCCB) TECHNICAL SPECIFICATION DOUBLE POLE FOUR POLE 44 Specification Reference IEC & IS : 2000 IEC & IS : 2000 Rated current (In) A 80, 100, , 100, 125 Sensitivity (I n) ma 30, 100, , 100,300, 500 Rated Voltage (Ue) V 240 VAC 240 / 415VAC Rated Insulation voltage (Ui) V Rated Frequency Hz Trip Time 1x In< 300ms, 5 x In <40ms Shortcircuit withstand Capacity ka Residual making breaking capacity A 10 In 10 In Ambient Temperature o C -25 to to +40 Shock Resistance g Vibration Resistance g 5 5 Electrical Endurance operations >2000 >2000 Mechanical Endurance operations >5000 >5000 Mounting Din Rail (35 x7.5) mm 35mm Din Rail Degree of protection IP 20 IP 20 Terminals capacity (max) mm
12 (80A - 125A RCCB) DOUBLE POLE Current Sensitivity Cat No. rating (A) ma RVD RVD RVD RVD RVD RVD RVD RVD RVD FOUR POLE Current Sensitivity Cat No. rating (A) ma RCF RCF RCF RCF RCF RCF RCF RCF RCF RCF DIMENSIONS (IN MM)
RESIDUAL CURRENT CIRCUIT BREAKER
Quality Features Mid Trip - Different knob position to indicate whether the device is Switched OFF by a fault or Switched OFF manually Inscription Window - Ensures circuit identification and hence reduces
More informationThe young energy ensures more safety
The young energy ensures more safety Domestic Products Catalogue 2017 CORPORATE OFFICE ABOUT STANDARD STANDARD is a brand of India s leading FMEG company, Havells India Ltd., that offers a wide range of
More informationUnrestricted. S.Mukhopadhyay
Unrestricted S.Mukhopadhyay 10.09.15 Electrical safety A report says that every year 5500 Indians die due to electric shock and 800 due to electric fire. 12% work place death due to electrocution ELECTRICAL
More informationWorking Principle of Earth Leakage Circuit Breaker (ELCB) and Residual Current Device (RCD)
Working Principle of Earth Leakage Circuit Breaker (ELCB) and Residual Current Device (RCD) Schneider Electric RCBO Earth Leakage Circuit Breaker (ELCB) An Earth Leakage Circuit Breaker (ELCB) is a device
More informationElectrical Workplace Safety
Electrical Workplace Safety Alan Kelly 23 rd September 2015 Objectives To provide an understanding of Electrical terms and the concepts of electricity To introduce Electrical Protective Devices and provide
More informationElectrical Hazard Three factors determine the resistance of a substance to the flow of electricity: conductors insulators extreme caution
Electrical Safety Electrical Hazard Three factors determine the resistance of a substance to the flow of electricity: What it is made of. Its size. Its temperature. Substances with very little resistance
More informationMiniature Circuit Breaker
Introduction - Miniature Circuit Breaker (MCB) SALIENT FEATURES SALIENT FEATURES Standards MCBs conform to the latest standard IS 8828: 1996/IEC: 898 1995 Mid-Trip Position The Mid trip position of the
More informationELECTRICAL. 60 Minutes
ELECTRICAL 60 Minutes AGENDA Electrical definitions Electrical shocks, burns and secondary injuries Electrical hazards in the workplace Safety devices and prevention steps Do s and Don ts INTRODUCTORY
More informationThe University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6
The University of New South Wales School of Electrical Engineering and Telecommunications Industrial and Commercial Power Systems Topic 6 PROTECTIONS 1 FUNCTION OF ELECTRICAL PROTECTION SYSTEMS Problems:
More informationAn average of one worker is electrocuted on the job every day There are four main types of electrical injuries:
Electrical Safety Introduction An average of one worker is electrocuted on the job every day There are four main types of electrical injuries: Electrocution (death due to electrical shock) Electrical shock
More informationElectrical Safety. Electrical Safety Webinar. Electrical. Printing Industries Alliance Printing Industries Alliance 1
Webinar 1 Electrical 2 1 Webinar Introduction An average of one worker is electrocuted on the job every day There are four main types of electrical injuries: Electrocution (death due to electrical shock)
More informationELD Earth Leakage Protection Relay
ELD Earth Leakage Protection Relay Designed and Manufactured in Australia by Ampcontrol Pty Limited ACN 000 915 542 Phone: (02) 4956 5899 Fax: (02) 4956 5985 www.ampcontrol.com.au No copies of the information
More informationDomae. The right solution for distribution boards
Domae The right solution for distribution boards Guaranteed quality and adapted solutions Domae : SIRIM approved The quality marks prove product conformity to their reference standard. They guarantee:
More informationschneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.
K0 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads Overview K0 Circuit Breaker Technical Specification MCB RCCB K0 Circuit Breaker K0N K0H ID K Number of poles
More informationPower systems Protection course
Al-Balqa Applied University Power systems Protection course Department of Electrical Energy Engineering Dr.Audih 1 Part 3 Protective Devices Fuses & Circuit Breakers 2 Introduction: Fuse Is advice used
More informationMINIATURE CIRCUIT BREAKER
Technical Article MINIATURE CIRCUIT BREAKER T 146 PURCHASE he Spaceage MCB protects wires and cables automatically against overload and short-circuits in domestic, commercial and industrial installations.
More informationSchneider Electric India As a global specialist in energy management with operations in more than 00 countries, Schneider Electric offers integrated s
NeoBreak Distribution System MCBs, RCCBs & DBs inspired innovation for round the clock protection Schneider Electric India As a global specialist in energy management with operations in more than 00 countries,
More informationPreventing Electrocutions and Injury with Industrial GFCIs. White Paper
Preventing Electrocutions and Injury with Industrial GFCIs White Paper Introduction Hundreds of people in the United States are killed by electricity every year, and several times that number are shocked
More informationDX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data
Specifications IS/IEC 60898-1 2002 Number of poles SP, SPN, DP, TP, TPN, FP Characteristics C & D Curve Breaking capacity 10 ka 0.5 A to 63 A as per IS/IEC 60898-1 2002 16 ka for 0.5 A to 25 A as per IEC
More informationTechnical guide Protection against earth faults with Residual Current Devices
Technical guide 2015 Protection against earth faults with Residual Current Devices Protection against earth fault with Residual Current Devices Introduction Protection against earth faults 2 Residual
More informationCharacteristics of LV circuit breakers Releases, tripping curves, and limitation
Characteristics of LV circuit breakers Releases, tripping curves, and limitation Make, Withstand & Break Currents A circuit breaker is both a circuit-breaking device that can make, withstand and break
More informationQUALITY ASSURANCE & DOCUMENTATION
QUALITY ASSURANCE & DOCUMENTATION RTECK IMPORTED PRODUCT STATEMENT Rteck has sourced most product from a large and reputable Chinese product manufacturer who specialise in the manufacture of modular electrical
More informationMINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS
MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MANUFACTURED IN THE EU EUROPEAN QUALITY 1, 2 & 3 POLE MCB s TRIPPING CURVES C & D CURRENT RATINGS 1AMP TO 63AMPS 10KA BREAKING CAPACITY
More informationBasic. Electrical Safety. January 2009
Basic Electrical Safety January 2009 Sunday, 10 January 2010 The complete circuit A complete Circuit or loop is necessary for current to flow Sunday, 10 January 2010 2 A complete circuit complete Circuit
More informationElectrical Safety in Die Casting
Electrical Safety in Die Casting April 2016 Beau Glim NADCA Project Manager NADCA Safety Series 4 parts Basic Safety Machine Maintenance Safety Electrical Safety Managing Safety General safety information
More informationR.C.B.O. SP / 1 module
87045 LIMOGES Cedex - France Telephone : (+33) 5 55 06 87 87 Fax : (+33) 5 55 06 88 88 R.C.B.O. SP / 1 module 6064 04 6064 64 05 6064 10 6064 11 6064 12 CONTENTS PAGES 1. Description, use... 1 2. Range...
More informationTechnical Journal September 2012
Technical Journal September 2012 Earth leakage protection in polluted low voltage network In present day irrespective of the application be it in process industry or in IT industry, Pollution of electrical
More informationब जल स स रक ष ELECTRICAL SAFETY. Dr. H. K. Verma Distinguished Professor (EEE) Sharda University, Greater Noida
ELECTRICAL SAFETY ब जल स स रक ष Dr. H. K. Verma Distinguished Professor (EEE) Sharda University, Greater Noida (Formerly: Deputy Director and Professor of Electrical Engg. Indian Institute of Technology
More informationJtec 10kA Miniature Circuit Breaker
EN 60898 Jtec 10kA Miniature Circuit Breaker Techna s JTEC range has been enthusiastically adopted by a diverse range of customers seeking a cost effective 10kA performance. Jtec MCBs are available in
More informationPD-Series Ground Fault Circuit Protection
PD-Series Ground Fault Circuit Protection SmartGuard is an equipment ground fault protection device that functions as a standard high-quality Carling hydraulic/ magnetic circuit breaker, offering customized
More informationP.1 CONTENTS. Industrial Earth Leakage Protection. Page
Industrial earth leakage protection P 1 P.1.01 GB CONTENTS Page Introduction 3 Earth leakage protection 4 Immunized earth leakage protection 5 Measurement in TRMS and Class A 6 Immunity against transient
More informationElectrical Energy and Power Ratings
Section 1 - From the Wall Socket Electrical Energy and ower Ratings Batteries and the mains are sources of electrical energy. Electrical appliances can then convert this into other forms of energy. e.g.
More informationCircuit Breaker Prepared By :
Circuit Breaker Prepared By : Eng : Ayman Soliman Selmy Circuit Breaker Specification of circuit Breaker:- [1] Operating voltage of C.B [2] Rated current of C.B (Ir or In) Amp. [3] Instantaneous short
More informationDPX moulded case circuit breakers
BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.
More informationELECTRICAL SAFETY. Safety Training For The Non-Qualified
ELECTRICAL SAFETY Safety Training For The Non-Qualified LANGUAGE OF ELECTRICITY Electricity: Negatively Charged Particles Moving Over A Conductor Current: Movement Of Electrons Along A Conductor Ground
More informationOPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2
OPERATING AND MAINTENANCE MANUAL Product: Type: Primary Current Injection Test Set 750ADM mk2 750ADM-H mk2 DESIGNED AND MANUFACTURED BY: T & R Test Equipment Limited 15-16 Woodbridge Meadows, Guildford,
More informationCat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s 0090 00/01/02/06/07/11/12/13/14 0/01/02/06/07/11/12/13/14/18/19/23/24/25/26/ /18/19/23/24/25/26/45/46 45/46 0090
More informationDSE201 Compact design with enhanced protection
DSE201 Compact design with enhanced protection The best of safety DSE201 6 ka: the highest level of reliability The 1P+N electronic residual current circuit-breakers with overcurrent protection (RCBOs)
More informationElectrical Safety - Protecting Yourself Against Electrical Injuries. from NIOSH Electrical Safety Student Manual
Electrical Safety - Protecting Yourself Against Electrical Injuries from NIOSH Electrical Safety Student Manual Oct 9 11:26 AM 1 Electricity is Dangerous There is a risk of an electrical injury - 1. Whenever
More informationTX³ RCCBs 2P up to 100 A
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 TX³ RCCBs CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationDZ47LE C45LE Residual Current Circuit Breaker with Over Current Protection
DZ47LE 1P+ DZ47LE C45LE Residual Current Circuit Breaker with Over Current Protection DZ47LE C45LE RCBO is used for the protection against electrical leakage in the circuit of 50Hz or 60Hz, rated voltage
More informationDPX Thermal magnetic and trip-free switches DPX 3 -I 630
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 2 6. CONFORMITY
More informationPage. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases
Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar
More informationBtdin RCBO 6000A up to 63A (2P)
Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics.... 4-29 6. Compliance - Approvals... 30 7. Curves... 30-34 8.Auxiliaries-
More informationSLOVAK UNIVERSITY OF TECHNOLOGY Faculty of Material Science and Technology in Trnava ELECTRICAL ENGINEERING AND ELECTRONICS.
SLOVAK UNIVERSITY OF TECHNOLOGY Faculty of Material Science and Technology in Trnava ELECTRICAL ENGINEERING AND ELECTRONICS Róbert Riedlmajer TRNAVA 2007 Unit 14 - Fundamentals of power system protection
More informationMotor Protection Circuit Breakers 3VU13 and 3VU16
Motor Protection Circuit Breakers 3VU13 and 3VU16 3VU13/3VU16 is suitable for use in fuseless motor feeders upto 11KW/22KW (25A/63A) respectively. 3VU motor protection circuit breakers are used for protection
More informationECET Distribution System Protection. Overcurrent Protection
ECET 4520 Industrial Distribution Systems, Illumination, and the NEC Distribution System Protection Overcurrent Protection One of the most important aspects of distribution system design is system protection.
More informationA direct current (DC) circuit. L 26 Electricity and Magnetism [4] Alternating Current (AC) Direct Current DC. AC power
L 26 Electricity and Magnetism [4] A direct current (DC) circuit simple electrical circuits direct current DC Alternating current (AC) vs direct current (DC) electric power distribution household electricity
More informationDX³ RCCBs - ID 4P up to 100 A
87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ s - ID CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More information1 Phase electronic contactor (SC 1)
1 Phase electronic contactor (SC 1) - Rated operational voltage up to 600VAC 50/60 Hz - Rated operational current up to 15/30A/50/63A AC-1 - Control voltage from or - Compact modular design 22.5, 45, or
More informationLR9 F OVERLOAD RELAYS
Issued November 2009 DATA SHEET LR9 F OVERLOAD RELAYS Based on Schneider MKTED2050EN Catalogue General 6 Motor protection Operating conditions There are many possible causes of electric motor failure.
More informationR-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism
R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism R-MAG Features: Low maintenance 10,000 mechanical operations (five times ANSI requirements) Simple magnetic actuator Vacuum interruption Definite
More information01 Spectra Plus - Introduction
01 Spectra Plus - Introduction Standard features Conforming to IS13947-2/EN60947 2 Compact dimensions Available in 3P & 4P High performance microprocessor protection release Wide overload setting from
More informationData Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931
Data Bulletin 0931DB0101 July 2001 Cedar Rapids, IA, USA Ground-Censor Ground-Fault Protection System Type GC Class 931 09313063 GT Sensor Shunt Trip of Circuit Interrupter Window Area for Conductors GC
More informationProtection and control VIP30, VIP35. Relays technical manual
Protection and control VIP30, VIP35 Relays technical manual contents 1. presentation of the VIP30 and VIP35...3 2. use and settings...4 3. sensors and operating ranges... 4. connection scheme...9 5. assembly
More informationR-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A
R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A - 3700 A R-MAG The R-MAG is truly the next generation in vacuum circuit breakers, combining industry recognized magnetic
More informationNEW TX³ RANGE PROTECTION YOU CAN RELY ON
TX³ NEW RANGE TRUSTED PROTECTION FOR YOUR INSTALLATIONS GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES NEW TX³ RANGE PROTECTION YOU CAN RELY ON Designed to meet the requirements of
More informationKEWTECH. KT56 digital multi function tester. Instruction manual
KEWTECH KT56 digital multi function tester Instruction manual Contents 1 Safety Notice 1 2 Features and Principles of Measurement 3 3 Introduction 6 4 Specifications 7 5 Instrument layout 9 6 Operating
More information3 - Protection components Motor circuit-breakers
Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More informationSchool of Electrical and Information Engineering. ELEC High Voltage. University of Sydney. Dr Keith Mitchell. Engineering
University of Sydney School of Electrical and Information Engineering Dr Keith Mitchell ELEC 5205 - High Voltage Engineering ELEC 5205 - High Voltage Engineering 3. Switchgear Types of Power System Switchgear
More informationcor Long Run Experience
Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30
More informationEffective discrimination of protective devices
Effective discrimination of protective devices In the event of a fault occurring on an electrical installation only the protective device nearest to the fault should operate,leaving other healthy circuits
More informationInterchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI
. Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,
More informationElectrical Safety. Recognizing & Controlling Hazards
Electrical Safety Recognizing & Controlling Hazards Introduction Healthcare facilities, including hospitals, physician offices, laboratoratories, dental offices and beyond are vulnerable to a variety of
More informationCat N 3. OVERALL DIMENSIONS
Cat N Motor driven remote control module 87045 LIMOGES Cedex - FRANCE Telephone : + 33 5 55 06 87 87 Fax: + 33 5 55 06 88 88 Cat N : : 4 062 91 CONTENTS PAGE 1. Description - Use...1 2. Product range...1
More informationInstantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch
Features (1) All models fully comply with IEC regulations (2) Units can be mounted on a standard 35mm IEC rail (3) Residual current circuit breakers use an original Mitsubishi Electric IC securing reliable
More informationDPX 630 Thermal magnetic and trip-free switches DPX-I 630
87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 630 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. CONNECTION 2 6. ELECTRICAL AND MECHANICAL CHARACTERISTICS
More informationECET 211 Electric Machines & Controls Lecture 1-4 (Part 1) Electrical Safety in the Workplace Electrical Safety in the Workplace
ECET 211 Electric Machines & Controls Lecture 1-4 (Part 1) Electrical Safety in the Workplace Text Book: Electric Motors and Control Systems, by Frank D. Petruzella, published by McGraw Hill, 2015. Other
More informationGJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector
GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................
More informationSynergy EN product information
Synergy EN60947-4-2 product information Rated operational voltages U e 200Vac to 480Vac Rated operational currents I e See Rating Table Rating index See Sizing Guide Rated frequency/frequencies 50-60Hz
More informationBtdin RCD Add-on modules 125A for MCBs 1,5 modules per pole
Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics... 4 6. Compliance - Approvals... 6 7. Curves... 7 8. Auxiliares and
More informationOffers. QOvs RCBO residual current devices. Protection Earth leakage protection. Variants
devices Offers This page must be removed before publishing The Schneider Electric residual current devices range comprises various offers (A, B, C, D) so as to be as competitive as possible in each country,
More informationic60h (6kA) single module combined RCD/MCB units ic60h (10kA) single module combined RCD/MCB units ild residual current circuit breakers idpn N Vigi
Contents Miniature circuit breakers ic60n miniature circuit breakers 6kA, C curve, 6-63A ic60h miniature circuit breakers 10kA, C curve, 6-63A ic60n miniature circuit breakers 6kA, B curve, 6-63A ic60h
More information(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2
Solid-state Contactor (New Heat Sink Construction) G3PB Space and working time saved with new heat sink construction. Series now includes 480-VAC models to allow use in a greater range of applications.
More informationThree-phase 200 V series: FRN0025 to 0060C2S-2U Three-phase 400 V series: FRN0013 to 0030C2S-4U
Instruction Manual Supplement for FRN-C2S-2U/4U (7.5 to 20 HP) Compact Inverter 200 V series: FRN0025 to 0060C2S-2U series: FRN0013 to 0030C2S-4U Thank you for purchasing our FRENIC-Mini series of inverters.
More informationAbout us. Switchgear Factory, Mumbai
Wires & Cables About us Larsen & Toubro is a technologydriven USD 9.8 billion company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field of Engineering,
More informationInsulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit
SSR with Failure Detection Function Detects failures in SSRs used for heater temperature control and simultaneously outputs alarm signals. This product supports the safe design of heater control systems,
More informationSemiconductor (AC) fuses
Main characteristics 450 TO 700VAC / 63 TO 2800A Recognized Exceptionally low I 2 T, Watt losses. Non-magnetic construction, Highly reliable low voltage Trip-indicator system, conformity to UL, IEC, DIN
More informationUnderstanding RV Electrical Hazards. Do you really want to plug in here?
Understanding RV Electrical Hazards Do you really want to plug in here? John Slaughter RV owner for 12 years, 150,000 miles of travel. Electrical Engineer Full disclosure, I am not a safety expert. Takeaways
More information(Miniature Circuit Breaker)
(Miniature Circuit Breaker) Features : l Uniform 10KA breaking capacity for B and C Curve l Low power consumption, thus cost effective & energy saving l Suitable for DC and for a wide frequency range of
More informationService Entrance Methods
Service Section Typical switchboards consist of a service section, also referred to as the main section, and one or more distribution sections. The service section can be fed directly from the utility
More informationW Datasheet: Residual current circuit breaker, series PRIORI, 10kA, Typ B
W Datasheet: Residual current circuit breaker, series PRIORI, 10kA, Typ B W SCHRACK-INFO All-current sensitive RCCB ( type B, B+ and Bfq) B+ types also meet the requirements of superior fire-protection
More informationInnovation That Leads the Change
Innovation That Leads the Change Mitsubishi Electric s foray in the Low Voltage Switchgears segment in India marked the beginning of a series of innovations that are now gathering tremendous industry accolades..
More informationAF40... AF96 3-pole contactors Technical data
Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional
More informationNetwork Remote Power using Packet Energy Transfer
Network Remote Power using Packet Energy Transfer Stephen S. Eaves Eaves Devices, Inc. Charlestown, RI Stephen.Eaves@EavesDevices.com www.voltserver.com I. INTRODUCTION Network remote powering provides
More informationTeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series
Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current
More informationNew DX 3 High rating & breaking capacity
New High rating & breaking capacity a new range OF MOduLar CirCuiT BrEakErs up TO 125 a T new dx³ MCBs AN ENHANCED range for HIgH-pErforMANCE INstALLAtIoNs DX³ : the new Legrand MCBs with dx³, Legrand
More informationMCBs and RCDs LR TM 6000
MCBs and RCDs LR TM 6000 thermal magnetic MCBs from 6 A to 63 A B and C curves residual current devices from 25 A to 63 A AC and A types ± ± ± ± MCBs Single pole 230/400 V± Single pole neutral 230 V± (1)
More informationMiniature circuit breaker Application guide
Miniature circuit breaker Application guide Miniature Miniature circuit circuit breakers breakers Application S200 guide Introduction The circuit breaker plays an important role in providing over-current
More informationBS : C&G 2382 Outcomes 4
BS7671 2008: C&G 2382 Outcomes 4 Outcome 4 Protection for safety The candidate will be able to: 4.1 Identify the differences between basic and fault protection 4.2 State means of protection against electrical
More informationShort-circuit current limiter S800-SCL-SR
Short-circuit current limiter S800-SCL-SR 2 ABB Short-circuit current limiter S800-SCL-SR Self-resetting current limiting module S800-SCL-SR is ABB s innovative self-resetting current limiting module which
More informationElectrical network protection VIP30, VIP35. User s manual 12/2008
Electrical network protection VIP30, VIP35 User s manual 1/008 Safety instructions ANSI symbol. IEC symbol. Safety symbols and messages Read these instructions carefully and look at the equipment to become
More informationKD LV Motor Protection Relay
1. Protection Features KD LV Motor Protection Relay Overload (for both cyclic and sustained overload conditions) Locked rotor by vectorial stall Running stall / jam Single phasing / Unbalance Earth leakage
More informationOrdinary Level Physics SOLUTIONS: EFFECTS OF AN ELECTRIC CURRENT
Ordinary Level Physics SOLUTIONS: EFFECTS OF AN ELECTRIC CURRENT Safety Features and kilowatt hours The unit of energy is called the kilowatt hour One kilowatt hour is the amount of energy used by a 1000
More informationParamount HRC Cartridge
Paramount HRC Cartridge Eaton MEM HRC fuselinks are manufactured to exacting standards using precision assembly methods and undergo rigorous quality checking before dispatch including resistance testing
More informationCLP POWER HONG KONG LIMITED. SUPPLY RULES March 2001
CLP POWER HONG KONG LIMITED SUPPLY March 2001 ADVISORY SERVICE Advice concerning matters relating to the supply of electricity may be obtained free of charge from the Company. OTHER COMPANY PUBLICATIONS
More informationMARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions
4.4 Storage Conditions The FD650/R and FD500/T or FD600/T should be kept in warm dry conditions away from direct sources of heat or sunlight, with the battery removed and in such a manner as to preserve
More informationELECTRICAL INSTALLER EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET
Candidate Code No. EIN15 For Board Use Only Result Date Int Result Date Int ELECTRICAL INSTALLER EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET INSTRUCTIONS READ CAREFULLY Time Allowed: Three
More informationGet detailed information on many digital or printed supports, or contact your Area Commercial Manager
The RX 3 and DX-E ranges provide essential functions for the protection requirements of people and property in residential and small commercial buildings Two breaking capacities, 4500 and 6000 (IEC 60898-1)
More informationElectronic circuit breaker EBU10-T
Description The electronic circuit protector type EBU10-T (Electronic Breaker Unit) provides selective overcurrent protection in AC 230 V UPS systems. It consists of an MCB approved for short circuit interruptions
More information