RoHS PAT.P. ATXRL-10- P Supply method: Assembly terminal blocks only. ATXSL-10- P UP-SCREW TYPE. Supply method: Assembly terminal blocks only.
|
|
- Leslie McGee
- 6 years ago
- Views:
Transcription
1 RoHS PAT.P. UP-SCREW TYPE Locked by lever type: ATXRL-10- P Supply method: Assembly terminal blocks only. Locked by screw type: ATXSL-10- P Supply method: Assembly terminal blocks only.
2 Advantage Between panel and panel connection You must remove screw one by one It is possible to shorten time to connect and I/O check. It is possible to detach electric wire all together. Replace If ATX series is used when replacing, the stop time of the production line can be shortened. Existing control board New Control Panel Replace Master Control Panel Existing control board Master Control Panel New Control Panel Standardization Control Panel Control Panel Standardization of connection Power line (TB) Signal line (CN) Combine (ATX Series) Check / Test / Maintenance It is possible to shorten test time when the product is used in test equipment. Control Panel Control Panel Control Panel Test equipment
3 ATX-10 has two fixed types. Locked by lever type: ATXRL-10- P Locked by screw type: ATXSL-10- P Rating and Specification Rated voltage Applicable wire / Rated current Terminal screw Tightening torque Withstand voltage Insulation resistance Operating ambient temperature Relative humidity Contact resistance Durability Applicable standard 600 V 2mm 2 / 16A M3.5 x6.7l 1.4N m 2500 V / 1 min MΩ or more(dc500 V mega) 25 ~+60 ( no freezing or condensation) 45 ~85 % 5 MΩ or less times JIS C (NECA C 2811) Applicable solderless terminal Material Items ATXRL-10- P ATXSL-10- P Body insulator modified PPE(Black) Contact(under) Cooper alloy (Ni plate) Conductive plate(upper) Cooper alloy (Sn plate) Terminal screw Steel (zinc trivalent chromate plating) Coil spring Hard steel wire(zinc trivalent chromate plating) Terminal plate Steel (zinc trivalent chromate plating) Locked by screw type end plate upper side (A) PBT(Gray), under side (B) modified PPE(Black) upper side (A) modified PPE (Gray) under side (B) modified PPE (Black) Lock Flat nut Steel (zinc trivalent modified PPE (Gray) chromate plating) Lever modified PPE (Black) Fixation screw (for mount upper on under) modified PPE (Gray) Spring Steel (zinc trivalent chromate plating) Cover Name plate PC (Clear) PVC (White)
4 Locked by lever type: Order format: ATXRL-10- P :No.of poles(p) ( =2~20) Supply method: Assembly terminal blocks only. The following parts are assembled at the factory and shipped. ( Terminal blocks, End plates, Cover, Name plate, Din rail, Stoppers ) Total length of terminal block(l)= Terminal width(8 mm ) No.of poles(p)+ End plates / stoppers (36 mm ) Dimensions ( mm ) No. of poles(p) Total length of terminal block(l) Total length of DIN rail(a) Mounting hole pitch(b) Mass of assembled terminal block(g) ATXRL-10 - P Component Terminal block ATX g End plate set Cover Name plate Rail Stopper Prevent misinsert plate Spacer Option ATX-10L1R(A)( B) 15.6g GTY-13 S B(R)8A- CB-5 M-1LE DAV4 ATX-10-CP1(Option) ATX-10-SP ATX-10L2R(A)( B) 8.9g 18.0g B(R)8A-
5 FEATURES ATXRL-10- P It s easy to detach the product even in narrow place. More information is available at TOGI homepage How to detach by using lever 1Release the lock. 2Down the lever, detach the upper terminal block. How to operate the lever by using screw driver Screwdriver Insertion hole for lever operation 1When you released the lock, it appeared insertion hole for lever. Then insert screwdriver to the hole. 2Down the screwdriver, push up the upper terminal block. 3Operate the lever same as 2. Detach the upper terminal.
6 ATXRL-10- P SLIDE LOCK STRUCTURE Locked position Unlocked position It is possible to check just by looking. When it is locked, insertion hole will be closed. When it is locked, it won t be moved It is possible to successively attach on the same rail as follow. Spacer for adjacent install(locked by lever only) Unit 1 Unit 2 When installing side by side on the rail, Spacer is used between the units to prevent mutual interference. Unit 1 Unit 2 Space among units 2 mm Fix with stopper GTY13 for both ends of unit Total length of terminal block(l) Length of the rail(x) Length of total terminal block(l)= Terminal width (8 mm ) No. of poles(p) + 32 mm No. of units + 4 mm 1unit = 2P~20P Please fix the rail with over triple site, if(x)is over 500 mm.
7 Locked by Screw type: Order format: ATXSL-10- P :No.of poles(p) ( =2~20) Supply method: Assembly terminal blocks only. The following parts are assembled at the factory and shipped. ( Terminal blocks, End plates, Cover, Name plate, Din rail, Stoppers ) Total length of terminal block(l)= Terminal width(8 mm ) No.of poles(p)+ End plates / stoppers (20 mm ) Dimensions ( mm ) No. of poles(p) Total length of terminal block(l) Total length of DIN rail(a) Mounting hole pitch(b) Mass of assembled terminal block(g) ATXSL-10 - P Component Terminal block ATX g End plate set Cover Name plate Rail Stopper Prevent misinsert plate Spacer Option ATX-10L1(A)( B) 9.5g GTY-13 S B(R)8A- CB-5 M-1LE DAV4 ATX-10-CP1(Option) ATX-10-SP ATX-10L2(A)( B) 11.5g 18.0g B(R)8A-
8 Option parts Plate for prevention of incorrect insertion 1Insert a plate for the prevention of incorrect insertion in the under terminal blocks. ATX-10-CP1(Option) Plate, separated 2Cut the boss of the pairing upper terminal blocks with nippers. Please insert the plate deeply. A B B 3When it is not a right pair, the terminal block cannot be connected. C A C D D Do not push the upper terminal block strongly when it is not a pair. Breakage may occur. Operating precautions Don t attach / detach terminals when applying current. Locked by screw type Make sure to tighten up a fixation screw after assembling upper and under terminal block. Locked by lever type Please slide the lever to fixed position to remain lock after assembling upper and under terminal block. Distributor Gongencho, Osachi, Okaya-shi, Nagano-ken Japan info@togi.co.jp
Rating of certified products
Rating Model No. Rated voltage Applicable wire/rated current Tightening torque PT- PT- 0 PT-0 PT-0 PT- 800V 00V 1.mm2 16A 1.mm2 15A A A (8mm2) (50A) 95A 132A 175A 0mm2 2A 3A 2 mm2 A 8mm2 50A 75A 132A 175A
More informationPT Series. Use with DIN 35mm Rail. Installation of 15A to 600A Terminal Blocks on Rail Possible
PT Series Use with DIN 35mm Rail Installation of 15A to 600A Terminal Blocks on Rail Possible Different capacity terminal blocks can be assembled on one rail as a unit. Like PTU Series, PT-10 to PT150
More informationRU Series Universal Relays
Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator available on plug-in relays No internal
More informationOrdering Information. Text Surface-Mounting Signal Relay G6K
Surface-Mounting Relay with the World s Smallest Mounting Area and a Height of Only 5.2 mm ROHS compliant. Sub-miniature model as small as 5.2 (H) x 6.5 (W) x 10 (L) mm is ideal for high-density mounting.
More informationG6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information
with the World s Smallest Mounting Area Subminiature model as small as.2 (H). (W) (L) mm is ideal for high-density mounting ((U)-2F(-Y)). Low profile of.2 mm improves mounting efficiency ((U)-2F(-Y)).
More informationv1.1 DP3 Series Input/Output Connector Thunderbolt Technology Compatible Connector Training Module Copyright 2013 JAE Electronics, Inc.
v1.1 DP3 Series Input/Output Connector Thunderbolt Technology Compatible Connector Training Module Application Examples Laptops, Desktops, Ultrabooks Audio/ Video editing equipment Display devices Adapter/
More informationMini Free Mount Cylinder
Mini Free Mount Cylinder Series ø, ø, ø, ø, ø, ø1, ø Series 1 ction Stroke 1 2 0 0 0 Clean uto switch series None Rod end Male threaded Without thread Solid state switch D-F D-M9 D-M9 W Female threaded
More informationG7L. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops. Application Examples. Model Number Legend
A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops No contact chattering for momentary drops up to % of rated. Wide-range AC-activated coil that handles 1 to 1 or to
More informationTPC TYPE N21 FEATURES. [Conformable standards] UL1059(2004) File No.E82309 EN Certificate No.B Ground terminal block
Ground terminal block TPC TYPE FEATURES The TPC terminal block provides electrical continuity with the mounting rail (TUB) simply by wiring. Common grounding is ensured by connecting a ground wire to a
More informationARM1000/2000. Standard Specifications
.5- Regulator Manifold ARM000/000 4 connection methods Standard Specifications Fluid Proof pressure Max. operating pressure Set pressure range Ambient and fluid temperature Cracking pressure (Valve) Construction
More informationHS6B Series Sub-Miniature Interlock Switch. Direct Opening
HS6 Series HS6 Series Sub-Miniature Interlock Switch HS6 Key features include: Only 30mm x 15mm x 78mm Allows highest level of safety by having 3 contacts: dual load contacts + monitoring contact (ISO13849-1,
More information6mm and 14mm Slim Interface Relay
6mm and mm Slim Interface Relay RV8 Series 6mm Width Electromechanical Screw Terminal Solid State Spring Clamp Terminal PRODUCT DESCRIPTION IDEC 6mm and mm interface relays provide a compact solution for
More informationAdjustable Range Reflective Photoelectric Sensor Amplifier Built-in. panasonic.net/id/pidsx/global
3 Adjustable Range Reflective Photoelectric SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.549~ guide... P.3~ General precautions... P.55~ PHOTO PHOTO MEASURE panasonic.net/id/pidsx/global
More informationCJ1. Air Cylinder. Double Acting: ø4/single Acting, Spring Return: ø2.5, ø4 CJ1B 4 5 U4. How to Order/Double Acting
1 Air Cylinder Double Acting: ø/ingle Acting, pring Return: ø., ø eries Variations tandard eries Double acting ingle acting style B pring return B U mm For single acting type, refer to pages 6-- to.. How
More informationOPERATING MANUAL. High-efficiency AR Series. Stepping motor and driver package. Introduction. Applicable motor. Before use
HM-08 OPERATING MANUAL Stepping motor and driver package High-efficiency AR Series DC power input Built-in Controller Type (RS-8 communication function) Driver Introduction Before use Only qualified personnel
More informationLow Profile, Single Output, Non-Contact Angle/Position Sensors
TOCOS SENSORS Low Profile, Single Output, Non-Contact Angle/Position Sensors Features Thin 11mm angle/position sensor with 3-wire harness and connector offered as a standard assembly Reliable, durable
More informationModel Pressure range ON/OFF output Linear output
Authorised Distributors:- ASH & ALAIN INDIA PV LD S-1, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-112(India) el : 11-43797575 Fax : 11-43797574 E-mail : sales@ashalain.com Digital Sensor Sensor
More information3. Terminal Shape P : PCB terminals FS: Surface-mounting terminals, short FL : Surface-mounting terminals, long
Surfacemounting Relay Ultracompact and Slim DPDT Relay Suitable for highdensity mounting.(.7 mm (W). mm (L) 9 mm (H)). Dielectric strength of, VAC and an impulse withstand voltage of 2, V for 2 μs (conforms
More informationGH-5S. 5.6 times approx. Tightening torque 0.78N m or less. Disconnection Alarm Indicator
GA- SERIES Amplifier-separated Micro-size Inductive Proximity Sensor GH SERIES -N -U Slim & Small The amplifier is extremely slim, just mm thick. This results in a compact size even if several amplifiers
More informationFeatures. 2-wire type available. Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in)
817 Cylindrical Inductive Proximity Sensor SERIES Related Information General terms and conditions... F-3 Glossary of terms...p.1576~ guide... P.781~ General precautions... P.1579~ PHOTO PHOTO panasonic.net/id/pidsx/global
More informationSNP-8 Series Single mode FC CONNECTOR PLUG - for Angled-PC, Conical Shape -
DOCUMENT NUMBER S05-H036-02E Single mode FC CONNECTOR PLUG - for Angled-PC, Conical Shape - TECHNICAL SPECIFICATIONS Fiber Optic Products Division 296-1, MATSUHIDAI, MATSUDO-SHI, CHIBA, 270-2214 JAPAN.
More informationSwitching Power Supply
Switching Power Supply Miniature DIN-track Mounting DC-DC Power Supplies 3- and 7.5-W models. Inputs: 10 to 27 VDC (DC input) Outputs: 5, 12, 15, 24, ±12, and ±15 V. 65 mm depth enables mounting onto panels
More informationCT-2 CONNECTOR TERMINAL
Connector terminal for PLCs, PCs and various controllers CT-2 CONNECTOR TERMINL FETURES 1. One-touch wiring with the various controller types greatly reduces the time required for wiring operations. 2.
More informationFlow Switch Diaphragm Style Flow Switch IFW5 10 N Diaphragm style flow switch. Thread type. Nil. Body size Note)
[Option] The flow switch, series IFW is used for detection and confirmation of the flow as a relaying device for the general water applications in some various equipment such as cooling water fixture in
More informationonlinecomponents.com
COMPCT CONNECTOR TERMINL FOR REDUCED WIRING CT-2 CONNECTOR TERMINL ORDERING INFORMTION TYPES RoHS Directive compatibility information http://www.mew.co.jp/ac/e/environment/ CT2: CT-2 connector terminal
More informationFree position locking flat and compact cylinder UFCD Series
Space-saving cylinder ensures safety during work in power failures or accidents. Free position locking flat and compact cylinder UFCD Series Free position locking flat and compact cylinder UFCD Series
More informationOPERATING MANUAL. Table of Contents. 5 Phase Stepping Motor and Driver. PN Geared Type HP Precautions...Page 2
HP-4117-3 5 Phase Stepping and UPK W Series PN Geared Type OPERATING MANUAL C Table of Contents 1. Precautions...Page 2 2. Product Verification...Page 3 3. Names and Function of Parts... Page 4 4. Installation...Page
More informationSpace-saving installation Flexible motor mounting
Space-saving installation Flexible motor mounting compatible!! Pulse train input compatible Automatic actuator recognition Addition of new controller compatible with pulse trains Enables current position
More informationA Metal Head That's. Highly Durable and Provides Long-distance Detection. mm 7(M18 Model) Proximity Sensor with All-stainless Housing E2EF NEW
NEW Proximity Sensor with All-stainless Housing EEF Standard Model (Completely stainless- housing) A Metal Head That's * Highly Durable and Provides Long-distance Detection mm 7(M18 Model) *More than 0
More informationSwitches & Pilot Devices
Key features: Two button sizes: ø29 and ø4mm ead-free, ohs compliant, (EU directive 22/95/EC) Depth behind the panel: Standard - only 27.9mm for 1 to 4 contacts Unibody - only 23.9mm for 1NC or 2NC IDEC
More information2c 15A, 4c 10A polarized power relays
c 5A, 4c A polarized power relays SP RELAYS RoHS compliant Protective construction: Dust cover type Taking advantage of the 4-gap balanced armature mechanism, S relays have met a number of relay needs
More informationXA Series Emergency Stop Switches (w/removable Contact Block)
XA ø6 XA Series Emergency Stop Switches (w/removable Contact Block) The World s First ø6 mm, 4-contact Emergency Stop Switch. Compact size - only 7.9 mm deep behind the panel. Reliable Safe break action.
More information15A (2 Form C), 10A (4 Form C) COMPACT POWER RELAYS WITH HIGH SENSITIVITY
5A ( Form C), A (4 Form C) COMPACT POWER RELAYS WITH HIGH SENSITIVITY RELAYS RoHS Directive compatibility information http://www.mew.co.jp/ac/e/environment/ Taking advantage of the 4-gap balanced armature
More informationSafety Products. Safety Products. HS5E Series. HS5E Series Miniature Solenoid Locking Switch
HS5E Series HS5E Series Miniature Solenoid Locking Switch HS5E Key features include: World s smallest 4 contact solenoid interlock switch. (35 40 46 mm.) Four contacts. Gold-plated contacts. Spring lock
More informationFlow Switch Paddle Style Flow Switch IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type. (Equivalent to IP42)
Paddle Style [Option] Flow switches, series IF detect and confirm liquid, generally used in fields such as air conditioning, water supply equipment, etc. Piping sizes ranges from /4B to B. Wide range of
More informationLoad Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC
Power PCB Relay G6D-ASI Reduced board space ideal for high-density mounting (45% smaller than the surface area of G6B). Slim package: measures 6.5 W x 17.5 L x 12.5 H mm Switches loads up to 5 A, 250 VAC/30
More informationSuitable for conveyor lines without an air supply
Contact our sales office regarding a delivery date or a price since this is a special model. P107X-011E P: OW P.G.Information (pecialized product) Electric topper Cylinder LEBQ eries MC CORPORATION 4-14-1,
More informationSPECIFICATION 三洋精密株式会社. Page 1/8. Version: 0.2 Model name: NRS-2574 (i) Date: Date Originator Version Detail spec changes
Page 1/8 Date Originator Version Detail spec changes 09.11.04 T. Takagi 0.1 Reference specification 10.12.08 T. Takagi 0.2 Add recommended reflow profile SANYO SEIMITSU CO., LTD. 1771,NAKAMARUKO UEDA-SHI
More informationDigital display Pressure range ON/OFF output Linear output Model
Slim Digital Pressure Sensor E8CB/ CSM_E8CB DS_E 1 with Built-in Microcomputer and Digital Display Withstands a of 9 kpa and highly reliable. Incorporates a two-turn adjuster ensuring easy setting. Be
More informationMiniature Guide Rod Cylinder ±0.1. Mounting from 2 directions
Miniature Guide Rod Cylinder Series Non-rotating accuracy : Height ±0.1 Mounting from 2 directions idth Overall length Two auto switches can be mounted even for mm strokes Integral wiring/piping to one
More informationUnit specifications. Nil. Option 1. Power supply/output connection cable. Option 2
Series -PSE3 RoHS Remote Type 2-Color Display Digital Pressure Sensor Controller How to Order 2 3 4 5 Nil Options/Part No. L Input/Output specifications NPN2 output to 5 V output NPN2 output 4 to 2 m output
More informationHow to Order Manifold FD2. Manifold mounting. D DIN rail mount style Note) E Direct mount style. Note) C kit of SQ2000 only. Cable specifications
For details about certified products conforming to international standards, visit us at www.smcworld.com. Series SQ000 Plug Lead Unit How to Order Manifold SSQ 0 FD D Electrical entry F kit D-sub Connector
More informationModel Pressure range ON/OFF output Linear output
Digital Sensor Sensor with Easy-to-Read LED Display status can be checked at a glance from the red digital pressure value and analog bar displays. Measurement pressure is averaged by the chattering prevention
More information0.6mm Pitch Stacking Height 3mm to 16mm Connectors
.6mm Pitch Stacking Height 3mm to 16mm Connectors FX8, FX8C Series FX8 Series FX8C Series Note: that FX8 series and FX8C series are not mated with each other. Features 1. Stacking Height: 3mm to 16mm Stacking
More informationFlow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Enclosure
Paddle Style For details about certified products conforming to international standards, visit us at www.smcworld.com. Flow switches, series IF detect and confirm liquid, generally used in fields such
More informationHEAVY DUTY POWER RELAYS FEATURES
VDE VC HEAVY DUTY POWER RELAYS VC RELAYS Faston terminal Screw terminal mm 9 FEATURES VC power relays are designed for controlling heavy duty loads safely: Contact gap of 3 mm or more -point contacts for
More informationTURQUOISE STROKE SWITCHES
Long Stroke and Sliding Contact Construction Sealed Switches TURQUOISE STROKE SWITCHES 13.3 10.1 (Unit: ) RoHS compliant FEATURES For pin plunger type, it maintains a long stroke OT (Over Travel) with
More informationRectangular-shaped Inductive Proximity Sensor.
69 PHOTO PHOTO Rectangular-shaped Inductive Proximity Sensor -F/H SERIES Related Information Amplifi er General terms and conditions... P.1 Sensor selection guide...p.11~ / P.67~ Glossary of terms... P.19
More informationConvert a One-way Pull Curtain Track to Center Open
Convert a One-way Pull Curtain Track to Center Open The above picture shows the complete one-way pull curtain track, plus the parts and the necessary tools for the conversion slot screwdriver, Phillips
More informationHS1L Interlock Switches with Solenoid
HS1L Interlock Switches with Solenoid 3000N locking strength (largest in class)! * Suitable for large and heavy doors. Same actuator as HS1E (actuator retention force 3000N) Six contacts in a compact housing
More information0.6mm Pitch Stacking Height 3mm to 16mm Connectors
.6mm Pitch Stacking Height 3mm to 16mm Connectors FX8/FX8C Series FX8 Series FX8C Series Note: that FX8 series and FX8C series are not mated with each other. Features 1. Stacking Height: 3mm to 16mm Stacking
More informationInfilex ZM Zone Manager Model WY5122
Specifications/Instructions Infilex ZM Zone Manager Model WY5122 General Infilex ZM (Infilex: named for Infinity and Flexible ) Model WY5122, integrated into savic-net FX BMS (building management system),
More informationAir Cylinder. Series CJ1. Single rod 2.5. Single rod Spring return. How to Order/Double Acting. Applicable tubing
Air Cylinder Double Acting: ø/single Acting Spring Return: ø2., ø Variations Series Action Standard stroke Page Standard Double acting Single rod,, 1, 1-6 Single acting Single rod Spring return 2.,,, 1,
More informationHigh Current, Plastic Power Supply Connectors
High Current, Plastic Power Supply Connectors EM Series Attachable to DIN rail Back mount type Front mount type Features. 4-positions with high current capability (three-phase power supply and ground)
More informationTORQUE TRANSDUCER TMHS-*NM (for Torque Transducer) Instruction Manual. MinebeaMitsumi Inc. Sensing Device Business Unit
TORQUE TRANSDUCER TMHS-*NM (for Torque Transducer) Instruction Manual MinebeaMitsumi Inc. Sensing Device Business Unit Please read this manual thoroughly before attempting to use the equipment. Be sure
More informationSPECIFICATION 三洋精密株式会社. Page 1/10. Version: 0.1 Model name: NRS-3388(i) Date:
Page 1/10 Date Originator Version Detail spec changes 11.06.13 T. Takagi 0.1 Preliminary spec written SANYO SEIMITSU CO., LTD. 1771,NAKAMARUKO UEDA-SHI NAGANO-KEN JAPAN Approval Exam Check Design Page
More informationFlow Switch Paddle Style Flow Switch. How to Order IF3 1 1 N Paddle style flow switch. Dripproof/Rainproof type (Equivalent to IP42)
Series IF [Option] Flow switches, series IF detect and confirm liquid, generally used in fields such as air conditioning, water supply equipment, etc. Piping sizes ranges from /B to B. Wide range of applicable
More informationDP the market leading digital code switch series are designed for use in wide range of industrial instruments. Features
Digital Code Switch DP Series Outline DP the market leading digital code switch series are designed for use in wide range of industrial instruments. Features High reliability with double gold-plated sliding
More informationType Plunger Switch height Operating force Model Without ground terminal With ground terminal. 5.0 mm General-purpose: 100 g 150 g
Tactile Switch BF Miniature, Space-Saving Tactile Switch Provides Long Service Life and Easy Mounting Extended mechanical/electrical service life: 0 x 0 6 operations for x mm type and x 0 6 operations
More informationCOMPACT BUT CUT OFF DC POWER CURRENT, POWER CAPSULE CONTACT RELAY
COMPACT BUT CUT OFF DC POWER CURRENT, POWER CAPSULE CONTACT RELAY EB RELAYS (AEB) (1A type) FEATURES Compact and high capacity using double contacts in series and permanent magnet installed. (1,A/3 times)
More informationSeries 10-ZSE40A(F)/10-ISE40A
Series 10-ZSEA(F)/10-ISEA RoHS 2-Color Display High Precision Digital Pressure Switch How to Order For positive pressure Clean series For vacuum/ compound pressure 01 N01 W1 10 Rated pressure range ISEA
More informationNot affected by drops, bubbles or froth
PARTICULAR USE SENSORS SERIES Sensor Detects water...reliably! Strong penetration power Not affected by drops, bubbles or froth Conforming to EMC Directive UL Recognition (Excluding m cable length type)
More informationSeries CRB2. Rotary Actuator Vane Style. Size: 10, 15, 20, 30, 40 CRB2 CRBU2 CRB1 MSU CRJ CRA1 CRQ2 MSQ MRQ D- 20- Series Variations.
Rotary Actuator Vane Style Series :,,,, 4 1 Series Variations Standard Vane type Port location Rotating angle Shaft type Fluid (S) ouble vane () Side ported (Nil) Axial ported (E) 9 18 27 ouble shaft W
More informationInformation. Model LEYG16 LEYG25 LEYG32
Information A rod type with guide newly added! Compatible with slide-bearing and ball-bushing bearing. Compatible with moment load and stopper (slide bearing). Speed control/positioning: ax. points Positioning
More informationE2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models
Long-barrel Inductive Proximity Sensor E2E2 Proximity Sensor with a Long Screw Length Increased tightening strength. Cable protectors provided as a standard feature. Increased indicator visibility. A milled
More informationPower Transfer Door Loops
Power Transfer Door Loops Patented, Durable and Tamper Resistant GEM Power Transfer Door Loops offer a protective means of running wires from the frame to door installed with electrical devices, such as
More informationAnalog Input Terminal
Analog Input Terminal I/O Interface Converts Analog Input Data into Binary Data Four inputs available. High resolution of 1/6000. Conversion is possible within a range of 5% to 105% FS. High conversion
More informationAir Cylinder. Single rod 2.5. Single rod Spring return. How to Order/Double Acting. Applicable tubing. Symbol Tube material Polyurethane Soft nylon
Air Cylinder Double Acting: ø/ingle Acting pring Return: ø2., ø Variations eries tandard B Basic mm Double acting ingle acting ingle rod ingle rod pring return 2. tandard stroke,, 1,,,, 1, How to Order/Double
More informationSOLENOID VALVES SERIES
VALVES GENERAL CATALOG SOLENOID VALVES SERIES INDEX Features 133 Basic s and Configuration 133 Specifications 13 Solenoid Valve Order s 137 Manifold Order s 138 Operating Principles and Symbols 139 Dimensions
More informationIndicating Meter for Special Instrumentation. DEF-15S.D.W DEF-17S.W Indicating Meter for Instrumentation CAT.NO.EF-15,17,100N-02 DEF-15W DEF-17W
DEF-7W DEF-W DEf-NWT DEf-NST DEF-S.D.W DEF-7S.W Indicating Meter for Instrumentation DEf-N Indicating Meter for Special Instrumentation CAT.NO.EF-,7,N- Contents Indicating Meters for Instrumentation DEF-S,
More informationInformation. Electric Slide Table/In-line Motor Type. Series LESH D. In-line motor type newly added to electric slide table!
Information kihabara UDX F, --, Sotokanda, Chiyoda-ku, Tokyo 0-00, PN UR http://www.smcworld.com 0 SMC Corporation ll Rights Reserved Electric Slide Table/In-line Motor Type Series ESHD In-line type newly
More informationRectangular Multi-connector. No. of Connecting Tubes: 10, 20. Plate. Plug connector Socket connector PAT.PEND
Rectangular Multi-connector KDM Series No. of Connecting Tubes: 1, 2 RoHS Multi-connector is effective in saving labor for separate transportation of the panel and the machine, and for exchanging units
More informationFree Mount Cylinder. Series. Series CU CAT.EUS20-95 B -UK. Space-saving. Auto Switch Capable P. 4, 23, 37 P. 45 P. 43
CAT.EUS- B -UK Free Mount Cylinder A space-saving air cylinder with multiple surfaces capable of direct mounting. Offered in many variations. Space-saving The multiple surface direct mounted rectangular
More informationANR SPECIFICATIONS. MATERIALS RoHS COMPLIANT - E222871
Wide variety of applications from consumer electronics to commercial Standard epoxy sealed terminations Gold contacts available for low power applications Available support brackets for greater stability
More informationINSTRUCTION MANUAL. Summing type Junction box SB 320
INSTRUCTION MANUAL Summing type Junction box SB 320 Note: Please read this Instruction manual carefully before use. Be sure to follow the items that require attention described in the manual. Keep the
More informationM3 Series Product. Class 0 - protection against electric shock relies upon basic insulation
Product Changeover circuit with rating 16A ong life snap action contacts mechanism Self-cleaning contact action Variety of actuators Screw, front screw or quick connect (faston) terminals dimensions according
More informationHS1L Interlock Switches with Solenoid
3000N locking strength (largest in class)! * Suitable for large and heavy doors. Same actuators as HS1E (locking strength 3000N) can be used. *As of October 2009, according to IDEC research of plastic
More informationSet value (Threshold value) Bottom value. *2 Further reduced by approx. 60% in power-saving mode (For 20 series)
3-Screen Display High-Precision Digital Pressure Switch New Added Variations! For general fluids IP65 2 outputs Analog output Setting is possible while checking Main screen the measured value. Sub screen
More informationHS1L Interlock Switches with Solenoid
3000N locking strength (strongest* in class)! Suitable for large and heavy doors. Same actuators as HS1E (locking strength 3000N) can be used. Six contacts in a compact housing (same size as HS1E)! Same
More informationManual override. Non-locking push type (Tool required) Nil: B: Locking type (Tool required) C: Locking type (Manual) Electrical entry
Plug-in nit Series 0 1 2 3 4 Series Type of actuation Metal Rubber 2 position single 3 position closed 3 position pressure Manifold Option How to Order Valves VQ 1 1 1 0 Y 5 LO Body type 1 0 1 Seal Metal
More informationAS Series. 4.0 g. Weight: Approx. 27% lighter. Flow Rate Reproducibility. Larger Knob. Easy Identification of Product Type. 5.5 g.
Speed Controller with One-touch Fittings In-line In-line Type y Easo t use RoHS Brass Stainless steel Reduces flow setting time! Push-lock type Knob O.D.: Almost doubled! Easy to lock ø9.4 Unlock ø5 Lock
More informationEMC SHIELDED PLASTIC BOX
PFE SERIES EMC SHIELDED PLASTIC BOX EMC Shielding Effects 4 PFE series is an EMC shielded version of the PF series network plastic box coated internally with DOTITE conductive paint (acrylic paint mixed
More informationFrequency 10 to 55 Hz, Amplitude 0.75mm Frequency 10 to 55 Hz, Amplitude 0.75mm. Frequency 10 to 55 Hz, Amplitude 0.75mm
Power Relays RL Series PRODUCT DESCRIPTION Quick Connect Flange Mount SPECIFICATIONS Number of poles pole 2 poles Contact Configuration X (SPST, double make) 2X (DPST, double make) Contact material Ag
More informationRotary Actuator. New RoHS. New. Vane Type 10, 15, 20, 30, 40. Many combinations available! Series CRB 2. Standard type/series CRB2
Rotary Actuator Vane Type 1, 15, 2, 3, 4 Standard Type Free Mount Type Many combinations available! Standard type/series Piping ports are located on the flat surface. Fittings can be secured firmly, piping
More information! Contact our sales office regarding a delivery date or a price since this is a special model. Auto switch D-M9 series mountable
! Contact our sales office regarding a delivery date or a price since this is a special model. P.G.Information (Specialized Product) Electric Stopper Cylinder/LEBH-X3 Series SP147X-019E-1 RP:SX SMC Corporation
More informationCylindrical Inductive Proximity Sensor GX-M SERIES
Cylindrical Inductive Proximity Sensor GX-M SERIES Listing (2 m cable length type only) Features Wide product range Types: DC 3-wire shielded type DC 3-wire non-shielded type DC 2-wire standard type DC
More informationACE VALVE COMPANY LIMITED
ACE VALVE COMPANY LIMITED Http://www.acevalve.co.kr 2013.04. ACE VALVE CATALOG 278-4 Mangdeokri, Juchonmyun, Gimhae, Gyeongnam, Korea. TEL +82--310-0 FAX +82--329-06~8 E-mail acevalve@acevalve.co.kr Homepage
More informationSubminiature Basic Switch
Subminiature Basic Switch Subminiature Basic Switch Offers Long Life and High Reliability A design that combines simplicity and stability by the use of two split springs ensures a long durability of 30,000,000
More informationMechanical power cylinder
Attaining thrust equivalent to a hydraulic cylinder -- with air pressure alone! New product Mechanical power cylinder MCP Series Mechanical power cylinder MCP Series CC-958A 1 Realize high thrust at any
More informationMiniature Regulator Series ARJ310
Miniature Regulator Series 30 Compact and lightweight (Main body 65 g) 8.3 Improved flow characteristics 0. 0. 0 00 00 300 400 500 Allows smaller mounting pitch 8.8mm 0-M5 30-0 Inlet pressure: MPa Accommodates
More informationHinges and Flap Fittings Furniture Hinges
Butt hinge Material: Steel Length: 50 mm Flange thickness: 1.5 mm Barrel Ø: 8 mm Crank A, straight Ø Gap1 mm Mounting Nickel plated matt Left 1.08.717 Right 1.08.708 Brass plated Left 1.08.511 Right 1.08.502
More information2-Color Display High-Precision Digital Pressure Switch
2-Color Display High-Precision Digital Pressure Switch Settings can be copied to up to 1 slave sensors at once. The settings of the master sensor can be copied to the slave sensors. Reduced setting efforts
More informationSpeed Controller with One-touch Fitting AS13 1F-M3 AS13 1F-M5. Specifications
Speed Controller with One-touch Fitting Series Minimizes installation time and cost Reduces the mounting height and enables compact machinery design. Effective area is larger than the former model. Tube
More informationLED Annunciator Lights. KFE-HD Series
LED Annunciator Lights KFE-HD Series KFE-24HD KFE-11HD KFE-13HD Features A variety of lighting areas, ranging from 8 34mm to 18 42mm are available. Five vivid lighting colors are available: milky white,
More information3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.
2-Color Display High-Precision Digital Pressure Switch Series ZSE3A(F)/ISE3A RoHS Can copy to up to 1 switches simultaneously. The settings of the master sensor can be copied to the slave sensors. Reducing
More informationHS1C Series Full Size Interlock Switch with Locking Solenoid. GS-ET-15 BG standard in Germany. HS1C Series Functionality
Full Size Interlock Switch with Locking Solenoid HSC Key features include: Rugged Aluminum Die-cast Housing With the actuator mounted on a movable door, and the switch on a machine, the door can be mechanically
More informationE2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models
Long-barrel Inductive Proximity Sensor EE CSM_EE_DS_E Proximity Sensor with a Long Screw Length Increased tightening strength. Cable protectors provided as a standard feature. Increased indicator visibility.
More information9.8 mm. Digital Pressure Switch. 3-step setting. RoHScompliant. Series ZSE10(F)/ISE10. Vertical mounting space reduced to approx.! Reduced in depth!
Digital Pressure Switch Series ZSE1(F)/ISE1 Low profile 26.1mm 9.8 mm 13.5 mm 53.4 mm Reduced in depth! (Actual size) RoHScompliant Vertical mounting space reduced to approx.! 1 2 Position Detection Switch
More informationSpecifications Fluid. Basic Roller lever. Mechanical operation. One way roller lever. Roller plunger. Push button (Flush) Manual operation
5 Port Mechanical Valve Metal Seal Series VZM400 Compact design, large flow capacity 9.9 mm 2 High cycle rate, long life/300 c.p.m. or less Piping possible to any EXH port. Proper countermeasures can be
More informationCOMPACT FLAT SIZE FOR AUTOMOTIVE
PACT FLAT SIZE FOR AUTOMOTIVE RELAYS RoHS compliant FEATURES Compact flat type Flat size enables it to be built-in switch units. PC board terminal type: 9.5 mm.374 inch Surface-mount terminal
More information