3. Terminal Shape P : PCB terminals FS: Surface-mounting terminals, short FL : Surface-mounting terminals, long

Size: px
Start display at page:

Download "3. Terminal Shape P : PCB terminals FS: Surface-mounting terminals, short FL : Surface-mounting terminals, long"

Transcription

1 Surfacemounting Relay Ultracompact and Slim DPDT Relay Suitable for highdensity mounting.(.7 mm (W). mm (L) 9 mm (H)). Dielectric strength of, VAC and an impulse withstand voltage of 2, V for 2 μs (conforms to Telcordia specifications (formerly Bellcore)). Conforms to FCC Part 8 (, V, μs). Singlewinding latching models to save energy. Standard models conforms to UL/CUL standards. RoHS Compliant Model Number Legend Application Relay function None : Singleside stable relay U : Singlewinding latching relay 2. Number of contact poles/ Contact form 2: 2pole/DPDT (2c) 3. Terminal Shape P : PCB terminals FS: Surfacemounting terminals, short FL : Surfacemounting terminals, long 4. Special function : Improved product for soldering heat resistance Communication equipment Test & measurement equipment Office automation equipment Audiovisual products Security equipment Building automation equipment Industrial equipment Amusement equipment Ordering Information Relay Function Singleside stable Singlewinding latching Packing Tube Packing Tape Packing Protective Structure Contact form Model Fully sealed DPDT (2c) 2P 2FS 2FL U2P U2FS U2FL Rated coil voltage Minimun packing unit Note. When ordering, add the rated coil voltage to the model number. Example: 2P DC3 Rated coil voltage However, the notation of the coil voltage on the product case as well as on the packing will be marked VDC. Note 2. When ordering tape packing, add TR" to the model number. Be sure since TR" is not part of the relay model number, it is not marked on the relay case. When ordering tape packing, minimum order unit is 2 reels (4 pcs 2 = 8 pcs). Model Rated coil voltage 4. VDC 4. VDC VDC VDC 2 VDC 2 VDC 24 VDC 24 VDC 4. VDC 4. VDC VDC 2FSTR 2FLTR VDC 2 VDC 2 VDC 24 VDC pcs/tube 24 VDC 4. VDC 4. VDC VDC VDC 2 VDC 2 VDC 24 VDC 24 VDC 4. VDC U2FSTR 4. VDC VDC U2FLTR VDC 2 VDC 2 VDC Minimum packing unit 4 pcs/reel Minimum ordering unit (tape packing) 8 pcs/ 2 reels

2 Ratings Coil: Singleside Stable Relays (2P, 2FS, 2FL) Rated voltage Note. The rated current and coil resistance are measured at a coil temperature of 23 C with a tolerance of ±%. Note 2. The operating characteristics are measured at a coil temperature of 23 C. Note 3. The maximum voltage is the highest voltage that can be imposed on the Relay coil instantaneously. Coil: Singlewinding Latching Relays (U2P, U2FS, U2FL) Rated voltage Surfacemounting Relay VDC % 7% % Approx. VDC VDC 9.,329.2 Note. The rated current and coil resistance are measured at a coil temperature of 23 C with a tolerance of ±%. Note 2. The operating characteristics are measured at a coil temperature of 23 C. Note 3. The maximum voltage is the highest voltage that can be imposed on the Relay coil instantaneously. Contacts Item Characteristics Rated current (ma) Coil resistance (Ω) Must operate voltage Must release voltage % of rated voltage Max. voltage Power consumption (mw) VDC VDC % % % Approx. 4 2 VDC VDC 9.2 2,. Approx. 23 Item Rated current (ma) Item Load Resistive load Contact type Bifurcated crossbar Contact material Ag (AuAlloy) Rated load.3 A at 2 VAC, A at Rated carry current A Max. switching voltage 2 VAC, VDC Max. switching current A Coil resistance (Ω) Must set voltage Must reset voltage % of rated voltage Max. voltage Power consumption (mw) Classification Singleside stable Singlewinding latching Item Model 2P, 2FS, 2FL U2P, U2FS, U2FL Contact resistance * mω Operating (set) time 3 ms Release (reset) time 3 ms Min. set/reset signal width ms Insulation resistance *2, MΩ (at VDC) Between coil and contacts, VAC, / Hz for min Dielectric strength Between contacts of different polarity, VAC, / Hz for min Between contacts of the same polarity 7 VAC, / Hz for min Between coil and contacts 2, VAC, 2 μs Impulse withstand Between contacts of different polarity voltage Between contacts of the same polarity, VAC, μs Vibration resistance Destruction to to Hz 2. mm single amplitude ( mm double amplitude) Malfunction to to Hz. mm single amplitude (3.3 mm double amplitude) Shock resistance Destruction, m/s 2 Malfunction 7 m/s 2 Durability Mechanical,, operations (at 3, operations/hour) Electrical, operations (with a rated load at,8 operations/hour) Failure rate (P level) (reference value) *3 μa at mvdc Ambient operating temperature 4 to 8 C (with no icing or condensation) Ambient operating humidity % to 8% Weight Approx.. g Note: The above values are initial values. *. The contact resistance was measured with ma at VDC with a fallofpotential method. *2. The insulation resistance was measured with a VDC Megger Tester applied to the same parts as those for checking the dielectric strength. *3. This value was measured at a switching frequency of 2 operations/min and the criterion of contact resistance is Ω. This value may vary depending on the operating frequency, operating conditions, expected reliability level of the relay, etc. Always doublecheck relay suitability under actual load conditions. 2

3 Engineering Data Surfacemounting Relay Maximum Switching Capacity Durability Ambient Temperature vs. Maximum Voltage Switching current (A) DC resistive load AC resistive load Durability (x 4 operations), VAC resistive load Ambient temperature: 23 C Switching frequency:,8 operations/hour resistive load Ambient temperature: 23 C Switching frequency:,8 operations/hour Maximum voltage (%) , Ambient Temperature vs. Switching Current Switching voltage Switching current (A) Ambient Temperature vs. Must Operate or Must Release Voltage Ambient temperature ( C) Note: Maximum voltage is the maximum voltage that can be applied to the Relay coil. Shock Malfunction Switching current (A) Ambient temperature ( C) Electrical Durability (with Operate and Release Voltage) * Change rate on the basis of rated voltage (%) Electrical Durability (Contact resistance) * Maximum estimated value avg. 4 3 avg. 2 Operating voltage Release voltage Ambient temperature ( C) X,, Z' Shock directions X X' Z Z' 2 4 8, ', Energized 8 Deenergized 4 2 ' Test Conditions: Shock is applied in ±X, ±, and ±Z directions three times each with and without energizing the Relays to check the number of contact malfunctions. Contact Reliability Test (Contact resistance) *, *2 Z,, X' Unit: m/s 2 Sample: 2P Number of Relays: pcs On the basis of rated voltage (%) Sample: 2P Number of Relays: pcs Test conditions: A resistive load at with an operation rate of % Switching frequency:,8 operations/hour Release voltage Contact resistance (mω), 3 3 Sample: 2P Number of Relays: pcs Test conditions: A resistive load at with an operation rate of % Switching frequency:,8 operations/hour Contact resistance NO contact NC contact Contact resistance (mω), 3 3 Sample: 2P Number of Relays: pcs Test conditions: μa resistive load at m VDC with an operation rate of % Switching frequency: 7,2 operations/hour Contact resistance NO contact NC contact..., Operating frequency (x 3 operations)..., Operating frequency (x 3 operations)..., Operating frequency (x operations) Mutual Magnetic Interference Mutual Magnetic Interference *. The tests were conducted at an ambient Sample Not energized Sample Energized Change rate on the basis of initial value (%) Change rate on the basis of initial value (%) Initial stage Initial stage Installed in flush configuration Average value Installed in flush configuration Average value Must operate voltage Must release voltage Sample Sample Not energized Energized Change rate on the basis of initial value (%) Change rate on the basis of initial value (%) Initial stage Installed in flush configuration Average value Initial Installed in flush stage configuration Average value Must operate voltage Must release voltage temperature of 23 C. *2. The contact resistance data are periodically measured reference values and are not values from each monitoring operation. Contact resistance values will vary according to the switching frequency and operating environment, so be sure to check operation under the actual operating conditions before use. 3

4 Surfacemounting Relay Change rate on the basis of initial value (%) External Magnetic Interference S N (Average value) Sample: 2P 3 Number of Relays: pcs Release voltage, ,2 External magnetic field (A/m) Highfrequency Characteristics Highfrequency (Isolation) *, *2 Isolation (db) poles (Average value (initial)) pole 9, Frequency (MHz) Change rate on the basis of initial value (%) S N (Average value) Sample: 2P 3 Number of Relays: pcs Release voltage, ,2 External magnetic field (A/m) Characteristics Highfrequency (Insertion Loss) *, *2 Insertion Loss (db).. 2 (Average value (initial)) pole 2poles 2., Frequency (MHz) Change rate on the basis of initial value (%) S N (Average value) Sample: 2P 3 Number of Relays: pcs Release voltage, ,2 External magnetic field (A/m) Characteristics (Return Loss, V.SWR) *, *2 Return loss (db) pole return loss pole return loss 2pole V.SWR pole V.SWR (Average value (initial)) 3. 7, Frequency (MHz) V.SWR Must Operate and Must Release Time Distribution * Distribution of Bounce Time * Vibration Resistance Number of contacts Sample: 2P Number of Relays: 3 pcs Operate time Release time Time (ms) Number of contacts Operate bounce time Release bounce time Sample: 2P Number of Relays: 3 pcs Time (ms) 4.. Initial *. The tests were conducted at an ambient temperature of 23 C. *2. Highfrequency characteristics depend on the PCB to which the Relay is mounted. Always check these characteristics, including endurance, in the actual machine before use. Change rate on the basis of rated value (%) Release voltage After 4

5 Dimensions Surfacemounting Relay (Unit: mm) PCB Terminals 2P U2P..7 PCB Mounting Holes (BOTTOM VIEW) Tolerance ±. mm Terminal Arrangement/ Internal Connections (BOTTOM VIEW) 2P 9 7. Eight,.8dia. holes (.) 7. Note: Each value has a tolerance of ±.3 mm. (.2) 8 7 U2P S R 8 7 Note:Check carefully the coil polarity of the Relay. Surfacemounting Terminals (Short) 2FS U2FS..7 Mounting Dimensions (TOP VIEW) Tolerance ±. mm Terminal Arrangement/ Internal Connections (TOP VIEW) 2FS (.) Note. Each value has a tolerance of ±.3 mm. Note 2. The coplanarity of the terminals is. mm.8 U2FS 8 7 S R Note:Check carefully the coil polarity of the Relay. Surfacemounting Terminals (Long) 2FL U2FL..7 Mounting Dimensions (TOP VIEW) Tolerance ±. mm 7. Terminal Arrangement/ Internal Connections (TOP VIEW) 2FL (.) Note. Each value has a tolerance of ±.3 mm. Note 2. The coplanarity of the terminals is. mm.8 U2FL 8 7 S R Note:Check carefully the coil polarity of the Relay.

6 Tube Packing and Tape Packing Surfacemounting Relay () Tube Packing Relays in tube packing are arranged so that the orientation mark of each Relay is on the left side. Always confirm that the Relays are in the correct orientation when mounting the Relays to the PCBs. 2. Reel Dimensions 2.±. 29.± 2±. 3±.2 dia. 2±. dia Stopper (gray) Orientation of Relays Stopper (green) A 33 8 R Enlarged View of Section A Tube length: mm (stopper not included) No. of Relays per tube: pcs (2) Tape Packing (Surfacemounting Terminal Relays) When ordering Relays in tape packing, add the prefix TR to the model number, otherwise the Relays in tube packing will be provided. Relays per reel: 4 pcs Minimum ordering unit: 2 reels (8 pcs). Direction of Relay Insertion Top tape (cover tape) Pulling Direction Pulling direction 24±.2 3. Carrier Tape Dimensions 2FS, U2FS, 2FL, U2FL ±. A 2±. ±. 4±. A 4 ± 9±. B B. +. dia. AA Cross Section.7±..8±. 8.4±..4±..±..3±..±. ± BB Cross Section 2.2±. Carrier tape Embossed tape ±. 8.3±. Recommended Soldering Method IRS Method (for Surfacemounting Terminal Relays) () IRS Method (Mounting Solder: Lead) Temperature ( C) 22 to 24 8 to 2 Soldering The thickness of cream solder to be applied should be between and 2 μm on OMRON's recommended PCB pattern. In order to perform correct soldering, it is recommended that the correct soldering conditions be maintained as shown below on the lefthand side. Correct Soldering Incorrect Soldering Relay Terminal Preheating Heel fillet is formed Land PCB 9 to 2 2 to 3 Time (s) (The temperature profile indicates the temperature on the circuit board.) (2) IRS Method (Mounting Solder: Leadfree) Solder Insufficient amount of solder Visually check that the Relay is properly soldered. Excessive amount of solder Temperature ( C) 2 23 Uppwe surface of case (peak): 2 C Soldering 8 Preheating Relay terminal section 2 3 Time (s) (The temperature profile indicates the temperature on the PCB.)

7 Approved Standards Surfacemounting Relay UL/CUL Recognized. (File No.E4) Contact form Coil rating Contact rating DPDT (2c) 2P, 2FS, 2FL: 3 to 24 VDC U2P, 2FS, 2FL: 3 to 24 VDC A, at 4 C. A, VDC at 4 C.3 A, 2 VAC at 4 C Number of test operations, Precautions Please refer to PCB Relays Common Precautions for correct use. Correct Use Long Term Current Carrying Under a longterm current carrying without switching, the insulation resistance of the coil goes down gradually due to the heat generated by the coil itself. Furthermore, the contact resistance of the Relay will gradually become unstable due to the generation of film on the contact surfaces. A Latching Relay can be used to prevent these problems. When using a singleside stable relay, the design of the failsafe circuit provides protection against contact failure and open coils. Handling of Surfacemounting Relays Use the Relay as soon as possible after opening the moistureproof package. (As a guideline, use the Relay within one week at 3 C or less and % RH or less.) If the Relay is left for a long time after opening the moistureproof package, the appearance may suffer and seal failure may occur after the solder mounting process. To store the Relay after opening the moistureproof package, place it into the original package and sealed the package with adhesive tape. When washing the product after soldering the Relay to a PCB, use a waterbased solvent or alcoholbased solvent, and keep the solvent temperature to less than 4 C. Do not put the relay in a cold cleaning bath immediately after soldering. Claw Securing Force During Automatic Insertion During automatic insertion of Relays, make sure to set the securing force of the claws to the following values so that the Relay characteristics will be maintained. A Direction A: 4.9 N Direction B: 9.8 N Direction C: 9.8 N Secure the claws to the area indicated by shading. C Environmental Conditions During Operation, Storage, and Transportation Protect the Relays from direct sunlight and keep the Relays under normal temperature, humidity, and pressure. B Mounting Latching Relays Make sure that the vibration or shock that is generated from other devices, such as Relays in operation, on the same panel and imposed on the Latching Relays does not exceed the rated value, otherwise the Latching Relays that have been set may be reset or vice versa. The Latching Relays are reset before shipping. If excessive vibration or shock is imposed, however, the Latching Relays may be set accidentally. Be sure to apply a reset signal before use. Maximum Allowable Voltage The maximum voltage of the coil can be obtained from the coil temperature increase and the heatresisting temperature of coil insulating sheath material. (Exceeding the heatresisting temperature may result in burning or shortcircuiting.) The maximum voltage also involves important restrictions which include the following: Must not cause thermal changes or deterioration of the insulating material. Must not cause damage to other control devices. Must not cause any harmful effect on people. Must not cause fire. Therefore, be sure not to exceed the maximum voltage specified in the catalog. As a rule, the rated voltage must be applied to the coil. A voltage exceeding the rated value, however, can be applied to the coil provided that the voltage is less than the maximum voltage. It must be noted that continuous voltage application to the coil will cause a coil temperature increase thus affecting characteristics such as electrical life and resulting in the deterioration of coil insulation. Coating Relays mounted on PCBs may be coated or washed. Do not apply silicone coating or detergent containing silicone, otherwise the silicone coating or detergent may remain on the surface of the Relays. Other Handling Please don t use the relay if it suffered the dropping shock. Because there is a possibility of something damage for initial performance. 7

8 Surfacemounting Relay Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. OMRON Corporation Electronic and Mechanical Components Company Contact: Cat. No. K2E7 8(27)(O) 8 Note: Do not use this document to operate the Unit.

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information with the World s Smallest Mounting Area Subminiature model as small as.2 (H). (W) (L) mm is ideal for high-density mounting ((U)-2F(-Y)). Low profile of.2 mm improves mounting efficiency ((U)-2F(-Y)).

More information

Ordering Information. Text Surface-Mounting Signal Relay G6K

Ordering Information. Text Surface-Mounting Signal Relay G6K Surface-Mounting Relay with the World s Smallest Mounting Area and a Height of Only 5.2 mm ROHS compliant. Sub-miniature model as small as 5.2 (H) x 6.5 (W) x 10 (L) mm is ideal for high-density mounting.

More information

PCB Relay. Single-side stable EN60950/EN41003 PCB terminal G6S-2 G6SU-2 G6SK-2 G6S-2-Y Surface mounting. stable

PCB Relay. Single-side stable EN60950/EN41003 PCB terminal G6S-2 G6SU-2 G6SK-2 G6S-2-Y Surface mounting. stable PCB Relay Surface Mounting DPDT Relay Long terminals for ideal for soldering and mounting reliability. Space-saving inside-l terminal. High dielectric strength between coil and contacts (2,000 VAC), and

More information

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment PCB Relay Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment High sensitivity can be driven by digital circuits. Horizontal design allows use in /2-inch PCB racks.

More information

PCB Relay. 2. Contact Form 2: DPDT 3. Terminal Shape None: PCB terminal F: Surface mount terminal

PCB Relay. 2. Contact Form 2: DPDT 3. Terminal Shape None: PCB terminal F: Surface mount terminal PCB Relay Ultracompact, Ultrasensitive DPDT Relay Compact size and low 5-mm profile. Low power consumption (140 mw for single-side stable, 100 to 300 mw for latching type) and high sensitivity. Low thermoelectromotive

More information

PCB Relay. Ordering Information. Surface Mounting DPDT Relay G6S

PCB Relay. Ordering Information. Surface Mounting DPDT Relay G6S PCB Relay Surface Mounting DPDT Relay Long terminals for ideal for soldering and mounting reliability. Space-saving inside-l terminal. High dielectric strength between coil and contacts (2,000 VAC), and

More information

PCB Relay. Contact form Terminal Single-side stable Single-winding latching

PCB Relay. Contact form Terminal Single-side stable Single-winding latching PCB Relay Subminiature, Sensitive SPDT Signal Switching Relay High sensitivity: 98 mw pickup coil power. Impulse withstand voltage meets FCC Part 68 requirements. Plastic-sealed construction. Unique moving

More information

Low Signal Relay. To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12).

Low Signal Relay. To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12). Low Signal Relay High sensitivity can be driven by digital circuits Low-profile design allows use in 12.70 mm (0.50 in) PC board rack Surge withstand voltage meets FCC Part 68 regulation Units can be mounted

More information

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC Power PCB Relay G6D-ASI Reduced board space ideal for high-density mounting (45% smaller than the surface area of G6B). Slim package: measures 6.5 W x 17.5 L x 12.5 H mm Switches loads up to 5 A, 250 VAC/30

More information

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC PCB Relay SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load Compact: 20 15 10 mm (L W H). Low power consumption: 200 mw. Flux protection or fully sealed construction available. Unique

More information

G7L. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops. Application Examples. Model Number Legend

G7L. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops. Application Examples. Model Number Legend A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops No contact chattering for momentary drops up to % of rated. Wide-range AC-activated coil that handles 1 to 1 or to

More information

PCB Relay RC+ Ordering Information. Subminiature Relay that Switches up to 5 A G6B VDC

PCB Relay RC+ Ordering Information. Subminiature Relay that Switches up to 5 A G6B VDC PCB Relay Subminiature Relay that Switches up to 5 A Subminiature: 20 10 10 mm (L W H). Low power consumption: 200 mw. Unique moving loop armature reduces relay size, magnetic interference, and contact

More information

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays Low-profile Relay with Various Models Low profile:.7 mm in height Clearance and creepage distance Between coil and contacts: 8 mm/8 mm Between contacts of the same polarity: 3 mm/4 mm Models with AC coil

More information

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend ealed ubminiature Basic witch ealed ubminiature Basic witch Conforming to IP67 (Excluding the terminals on terminal ) Use of epoxy resin assures stable sealing, making this switch ideal for places subject

More information

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed PCB Relay G5LA A Cubic, Single-pole 1A Power Relay Economical cube relay with universal terminal footprint Conforms to VDE435, CQC UL recognized/ CSA certified. High switching power: 1A @ 5VAC Withstands

More information

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend ealed ubminiature Basic witch ealed ubminiature Basic witch Conforming to IP67 (Excluding the terminals on terminal ) Use of epoxy resin assures stable sealing, making this switch ideal for places subject

More information

Power PCB Relay. Type Contact material Contact form Construction Part number General purpose AgCdO SPDT Semi-sealed G2R-1

Power PCB Relay. Type Contact material Contact form Construction Part number General purpose AgCdO SPDT Semi-sealed G2R-1 Power PCB Relay Creepage distance of 8.0 mm (0.31 in) min. between coil and contact Dual-winding latching type available Plug-in and quick-connect terminals available High sensitivity (360 mw) and high

More information

Ordering Information. Text PCB Power Relay G5LE

Ordering Information. Text PCB Power Relay G5LE A Cubic, Single-pole 10-A Power Relay Single-pole 10A 35VDC, 0.8mm contact gap: G5LE-G Single-pole 16A 250VAC: G5LE-E ROHS compliant. Sub-miniature sugar cube relay with universal terminal footprint. Conforms

More information

Tactile Switch. Ordering Information. A Wide Range of Models: 6 x 6 mm, 12 x 12 mm, Vertical, and High-force.

Tactile Switch. Ordering Information. A Wide Range of Models: 6 x 6 mm, 12 x 12 mm, Vertical, and High-force. Tactile Switch A Wide Range of Models: 6 x 6 mm, 1 x 1 mm, Vertical, and High-force. A positive click action plus a long life equal to that of a no-contact switch. Radial models (taping specifications)

More information

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL Terminal Relay Easy-to-use, Space-saving Terminal Relay with Four-point Output Almost the same size as PYF Socket: 31 x 35 x 68 mm (W x H x D) Each terminal circuit (with coil or contact) is independent

More information

D2VW. Sealed Miniature Basic Switch Conforms to IP67 (Excluding the terminals on terminal models) Model Number Legend. Sealed Miniature Basic Switch

D2VW. Sealed Miniature Basic Switch Conforms to IP67 (Excluding the terminals on terminal models) Model Number Legend. Sealed Miniature Basic Switch Sealed Miniature Basic Switch Conforms to IP67 (Excluding the terminals on terminal models) Use of epoxy resin assures stable sealing, making this switch ideal for places subject to water spray or excessive

More information

Model Number Structure

Model Number Structure Power Relay G7J Electromechanical Relays A High-capacity, High-dielectric-strength, Multi-pole Relay Used Like a Contactor Miniature hinge for maximum switching power for motor loads as well as resistive

More information

Tactile Switch (Hinged Type)

Tactile Switch (Hinged Type) Tactile Switch (Hinged Type) Hinged Design Developed through Ergonomics Quick, superior snap action through hook-type hinge construction. Available with 1 or LEDs or without LEDs. The hinge button is available

More information

D2AW. Long stroke seal switch with high reliability and high insulation performance. Model Number Legend. Sealed Ultra Subminiature Basic Switch

D2AW. Long stroke seal switch with high reliability and high insulation performance. Model Number Legend. Sealed Ultra Subminiature Basic Switch Long stroke seal switch with high reliability and high insulation performance Double reliability by twin contacts (=Clipping contact). Foreign materials are cleaned out by the sliding

More information

Single-pole 10A35VDC 0.8mm Contact Gap Power Relay : G5LE-G Single-pole 16A250VAC Power Relay : G5LE-E. Contact Form 10A 35VDC

Single-pole 10A35VDC 0.8mm Contact Gap Power Relay : G5LE-G Single-pole 16A250VAC Power Relay : G5LE-E. Contact Form 10A 35VDC PCB Relay R G5LE-E/-G Single-pole 0A35VDC 0.8mm Contact Gap Power Relay : Single-pole 6A250VAC Power Relay : G5LE-E Sub-miniature 'sugar cube ' relay with universal terminal footprint. UL class-f coil

More information

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h) Mechatronic Analog Timer H3AM Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty and

More information

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC PCB Relay Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications Compact, yet capable of switching up to 30-A loads. Complies with UL873 and UL508 column A spacings (1/8 through

More information

D2MV. Highly reliable Miniature Basic Switch in spite of its Ultra-low Load action. Model Number Legend. List of Models.

D2MV. Highly reliable Miniature Basic Switch in spite of its Ultra-low Load action. Model Number Legend. List of Models. Highly reliable iniature Basic Switch in spite of its Ultra-low Load action Twin crossbar contact employed for exceptionally high contact reliability. Unique internal mechanism that ensures high contact

More information

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC PCB Relay Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications Compact, yet capable of switching up to 30-A loads. Complies with UL873 and UL508 column A spacings (1/8 through

More information

G7S Safety Relay. Ordering Information. Safety Relay conforming to EN standard G7S. Accessories Safety Relay Sockets

G7S Safety Relay. Ordering Information. Safety Relay conforming to EN standard G7S. Accessories Safety Relay Sockets Safety Relay Safety Relay conforming to EN standard Conforms to pren50205. A minimum of 0.5 mm between contacts even when one contact is welded. (pren50205 Class A) Forcibly guided contacts. The contributes

More information

TL RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, etc. ORDERING INFORMATION TYPES. High Load Relay for Smart Junction Box ACTL.

TL RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, etc. ORDERING INFORMATION TYPES. High Load Relay for Smart Junction Box ACTL. High Load Relay for Smart Junction Box TL RELAYS High heat-resistant type: Sealed Pin in Paste compliant type: Flux tight New 14.4.7 11.433 1.3 FEATURES Large capacity switching

More information

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g. Tactile Switch BW Tactile Switch with Sealed Construction for Automatic Soldering Sealed construction conforming to IP67 (IEC-6059) provides high reliability in locations exposed to dust or water. Available

More information

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press Plug-In Safety Relay Safety Relay for Machine Control Conforms to EN Standard H Suitable for safety circuits in press machinery, machine tools, and other production machinery Do Not Remove H CE mark (conforms

More information

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A PCB Relay Miniature Single-pole Relay with 80-A Surge Current and 20-A Switching Current Ideal for motor switching. Miniature, relay with high switching capacity built-in applications. Creepage distance

More information

2c 15A, 4c 10A polarized power relays

2c 15A, 4c 10A polarized power relays c 5A, 4c A polarized power relays SP RELAYS RoHS compliant Protective construction: Dust cover type Taking advantage of the 4-gap balanced armature mechanism, S relays have met a number of relay needs

More information

Subminiature Basic Switch

Subminiature Basic Switch Subminiature Basic Switch Subminiature Basic Switch Offers Long Life and High Reliability A design that combines simplicity and stability by the use of two split springs ensures a long durability of 30,000,000

More information

Type Contact form Model Plug-in socket/solder terminals Hermetically sealed 4PDT MY4H-US

Type Contact form Model Plug-in socket/solder terminals Hermetically sealed 4PDT MY4H-US Hermetically Sealed Relay MY4H Hermetically Sealed Relay Ideal for Hazardous Locations Class 1 Division 2 approved. Fully hermetically sealed for hazardous locations. Cadmium-free contacts for environment-friendly

More information

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information D2SW-P

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information D2SW-P Sealed Subminiature Basic Switch Sealed Basic Switch with Simplified Construction, Mounting Compatible with SS and D2SW Series. Sealing by using rubber packing means the switch can be used in dust-proof

More information

PCB Relay. New G8P. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

PCB Relay. New G8P. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC PCB Relay Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications Compact, yet capable of switching up to 30-A loads. Complies with UL873 and UL508 column A spacings (1/8 through

More information

Mounting type Contact form PCB terminals Screw terminals Quick-connect terminals

Mounting type Contact form PCB terminals Screw terminals Quick-connect terminals Power Relay A High-capacity, High-dielectric-strength, Multi-pole Relay Used Like a Contactor Miniature hinge for maximum switching power for motor loads as well as resistive and inductive loads. No contact

More information

Type Plunger Switch height Operating force Model Without ground terminal With ground terminal. 5.0 mm General-purpose: 100 g 150 g

Type Plunger Switch height Operating force Model Without ground terminal With ground terminal. 5.0 mm General-purpose: 100 g 150 g Tactile Switch BF Miniature, Space-Saving Tactile Switch Provides Long Service Life and Easy Mounting Extended mechanical/electrical service life: 0 x 0 6 operations for x mm type and x 0 6 operations

More information

B3F. Miniature, Space-saving Switch

B3F. Miniature, Space-saving Switch B3F Miniature, Space-saving Switch Long mechanical / electrical service life Ideal for applications such as audio, office and communications equipment, TVs, etc Taped radial, vertical, high-force, and

More information

Mechanical Key Switch

Mechanical Key Switch Mechanical Key Switch B3F A Wide Range of Models: 6 x 6 mm, 12 x 12 mm, Vertical and High-force. Excellent tactile feel combined with high life expectancy. Available in stick packaging for automatic mounting

More information

D2SW-AQ. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

D2SW-AQ. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal ) Use of epoxy resin assures stable sealing, making this switch ideal for places subject to water spray or excessive

More information

Model Number Structure

Model Number Structure Terminal Relay G6B-4@@ND Compact Terminal Relay with 4 Independent Outputs Equipped with four G6B Mini-relays that are compact, highly sensitive, and highly resistant to dielectric surges, and that can

More information

Wire. Socket (with polarizing guide) Wire can be connected without stripping cable insulation. IDC contacts. Rise in temperature ( C)

Wire. Socket (with polarizing guide) Wire can be connected without stripping cable insulation. IDC contacts. Rise in temperature ( C) IDC Connectors for Discrete Wires Trouble-free discrete-wire termination with IDC Sockets that accommodate MIL Plugs. XG5 * Two-slot, IDC construction and insulation barrel offer high reliability and large-current

More information

TC RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, Defogger, Seat heater, etc. ORDERING INFORMATION. High Load Relay for Smart J/B ACTC

TC RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, Defogger, Seat heater, etc. ORDERING INFORMATION. High Load Relay for Smart J/B ACTC High Load Relay for Smart J/B TC RELAYS /High heat-resistant type: Sealed Pin in Paste compliant type: Flux tight FEATURES Large capacity switching despite small size. Can replace

More information

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries Safety Relay Unit Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries Two-pole slim models that are only 22.5 mm wide, three-pole models that are only 68 mm wide,

More information

General Purpose Relay

General Purpose Relay General Purpose Relay Designed small, 2- and 3-pole types break 5 A loads and 4-pole type, 3 A load High reliability, long life Ultra-high sensitivity with quick response High vibration/shock resistance

More information

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information Safety-door Switch Safety-door Switch s Special Operation Key Directly Pulls Apart the Contacts from Each Other and Contributes to the Safety of the Production Site Conforms to EN (TÜV) standards corresponding

More information

DATA SHEET. Compact and lightweight, High breakdown voltage, Surface mounting type

DATA SHEET. Compact and lightweight, High breakdown voltage, Surface mounting type DATA SHEET MINIATURE SIGNAL RELAY Compact and lightweight, High breakdown voltage, Surface mounting type DESCRIPTION The EE2 series surface-mounting type sustaining high-performance of NEC TOKIN EC2 series.

More information

Industrial Relay KML(1C, 2C)

Industrial Relay KML(1C, 2C) Industrial Relay KML(1C, 2C) Features 1C: 15A, 2C: 10A switching capability 1.5kV dielectric strength (between coil and contacts) Various terminals available Socket available 1 & 2 poles configurations

More information

Ordering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31

Ordering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31 Snap Action Switch Subminiature Snap Action Switch Switches 3 A loads (general-purpose), 1 A loads (low force general-purpose) and 0.1 A loads(microvoltage/ microcurrent) Long life span assured by high-precision

More information

FLAT/VERTICAL TYPE HIGH POWER BIFURCATED CONTACT

FLAT/VERTICAL TYPE HIGH POWER BIFURCATED CONTACT FLAT/VERTICAL TYPE HIGH POWER BIFURCATED CONTACT NC NC RELAYS Flat type Flat type (PC board) (PC board) FEATURES 1. Compact, slim design Use of high-performance flat electromagnetic design achieves 10.9

More information

15A (2 Form C), 10A (4 Form C) COMPACT POWER RELAYS WITH HIGH SENSITIVITY

15A (2 Form C), 10A (4 Form C) COMPACT POWER RELAYS WITH HIGH SENSITIVITY 5A ( Form C), A (4 Form C) COMPACT POWER RELAYS WITH HIGH SENSITIVITY RELAYS RoHS Directive compatibility information http://www.mew.co.jp/ac/e/environment/ Taking advantage of the 4-gap balanced armature

More information

POLARISED, MONOSTABLE SAFETY RELAY with (mechanical linked) forced contacts operation

POLARISED, MONOSTABLE SAFETY RELAY with (mechanical linked) forced contacts operation (SF3 pending) (SF3 pending) (SF3 pending) POLARISED, MONOSTABLE SAFETY RELAY with (mechanical linked) forced contacts operation SF-RELAYS π.098±.0.098±.0.098±.0 5.0.984 6.5±0.3.650±.0 33±0.3.99±.0 6.5±0.3.650±.0

More information

D2D. Door Interlock Power Switch with Minimum Contact gap of 3 mm. Model Number Legend. Contact Form. List of Models. Contact Specifications.

D2D. Door Interlock Power Switch with Minimum Contact gap of 3 mm. Model Number Legend. Contact Form. List of Models. Contact Specifications. Power/oor Switch oor Interlock Power Switch with Minimum Contact gap of mm Offers the minimum contact gap of mm required for power switches as standard equipment. Safety considerations include a double

More information

1 Form A 5A small size power relay for interface

1 Form A 5A small size power relay for interface 1 Form A 5A small size power relay for interface PQ RELAYS RoHS compliant Protective construction: Sealed type FEATURES 1. Compact and slim 20 mm (L) mm (W) 16 mm (H).787 inch (L).394 inch (W).630 inch

More information

DPDT BTA12-2C-S-C BTA12-2C-S-CL BTA12-2C-S-CLM SPST-NO-DM BTA12-1X-S-C BTA12-1X-S-CL BTA12-1X-S-CLM

DPDT BTA12-2C-S-C BTA12-2C-S-CL BTA12-2C-S-CLM SPST-NO-DM BTA12-1X-S-C BTA12-1X-S-CL BTA12-1X-S-CLM FEATURES Plug-in relay Quick connect receptacles or direct soldering. PCB terminals are also acceptable. Large capacity 30A contact rating. Optional blowout magnet: high dc switching. Wide spacing between

More information

Safety-door Switch. Ordering Information

Safety-door Switch. Ordering Information Safety-door Switch Safety-door Switch s Special Operation Key Positively Pulls Apart the Contacts from Each Other and Contributes to the Safety of the Production Site Special Operation Key prevents mis-operation.

More information

COMPACT FLAT SIZE FOR AUTOMOTIVE

COMPACT FLAT SIZE FOR AUTOMOTIVE PACT FLAT SIZE FOR AUTOMOTIVE RELAYS RoHS compliant FEATURES Compact flat type Flat size enables it to be built-in switch units. PC board terminal type: 9.5 mm.374 inch Surface-mount terminal

More information

General Purpose Relay

General Purpose Relay General Purpose Relay Exceptionally reliable general purpose relay Long life (minimum 100,000 electrical operations) assured by silver contacts Built-in operation indicator (mechanical, LED), diode surge

More information

COMPACT FLAT SIZE FOR AUTOMOTIVE

COMPACT FLAT SIZE FOR AUTOMOTIVE PACT FLAT SIZE FOR AUTOMOTIVE RELAYS RoHS compliant FEATURES Compact flat type Flat size enables it to be built-in switch units. PC board terminal type: 9.5 mm.374 inch Surface-mount terminal

More information

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2 Solid-state Contactor (New Heat Sink Construction) G3PB Space and working time saved with new heat sink construction. Series now includes 480-VAC models to allow use in a greater range of applications.

More information

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24 Solid State Relays (SSRs) G3PA/G3PB Long Service Life for Circuits that Cycle Frequently D D D D D Built-in heat sink increases life and reliability Voltage turn-on at zero crossing reduces initial inrush

More information

General Purpose Relay

General Purpose Relay General Purpose Relay Arc barrier equipped High dielectric strength (2,000 VAC) Long dependable service life assured by AgCdO contacts Choose models with single or bifurcated contacts, LED indicator, diode

More information

Ordering Information. General-purpose Basic Switch X. Direct Current Switch with Built-in Magnetic Blowout. Model Number Legend

Ordering Information. General-purpose Basic Switch X. Direct Current Switch with Built-in Magnetic Blowout. Model Number Legend General-purpose Basic Switch X Direct Current Switch with Built-in Magnetic Blowout Incorporates a small permanent magnet in the contact mechanism to deflect the arc to effectively extinguish it. Ideal

More information

2NC (slow-action) Direct. Model. opening

2NC (slow-action) Direct. Model. opening Small Safety Limit Switch CSM DS_E_3_1 Smallest Class of Safety Limit Switches in the World Note: Contact your sales representative for details on models with safety standard certification. The world's

More information

Standard Plug-in/solder SPDT LY1 LY1F DPDT LY2 LY2F LY2Z LY2ZF 3PDT LY3 LY3F 4PDT LY4 LY4F PCB SPDT LY1-0 DPDT LY2-0 LY2Z-0

Standard Plug-in/solder SPDT LY1 LY1F DPDT LY2 LY2F LY2Z LY2ZF 3PDT LY3 LY3F 4PDT LY4 LY4F PCB SPDT LY1-0 DPDT LY2-0 LY2Z-0 General Purpose Relay LY Arc barrier equipped. High dielectric strength (2,000 VAC). Long dependable service life assured by Ag-Alloy contacts. Choose models with single or bifurcated contacts, LED indicator,

More information

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure. Guard Lock Safety-door Switch Protective Doors Are Locked Until Machines Completely Stop Operating A mechanical lock is applied automatically when the Operation Key is inserted. A high level of safety

More information

Digital display Pressure range ON/OFF output Linear output Model

Digital display Pressure range ON/OFF output Linear output Model Slim Digital Pressure Sensor E8CC with Built-in Microcomputer and Digital Display Withstands a pressure of 49 kpa and highly reliable. Incorporates a two-turn pressure adjuster ensuring easy pressure setting.

More information

MIDDLE LOAD RELAY FOR SMART J/B

MIDDLE LOAD RELAY FOR SMART J/B MIDDLE LOAD RELAY FOR SMART J/B CN-M RELAYS (ACNM) New Compliance with RoHS Directive FEATURES. Best space savings in its class.. Compact and high-capacity A load switching.. Full line up (High heat-resistant

More information

TV-5, TV-8 rated 10mm flat power relays Silent type is available

TV-5, TV-8 rated 10mm flat power relays Silent type is available TV-, TV- rated 1mm flat power relays Silent type is available LK-F RELAYS TV standards compatible: TV- and TV- TV- type: 7 A inrush current and switching possible at A rated current. : 11 A inrush current

More information

Model Number Structure

Model Number Structure Small Sealed Switch D4E-@N Slim and Compact Switch with Better Seal and Ensuring Longer Service Life than D4E Flat springs with an improved lever ratio of the built-in switch ensure smooth snap action

More information

Ordering Information. Motor Timer H2A. Miniature, High-performance Motor. Motor Timer H2A 1

Ordering Information. Motor Timer H2A. Miniature, High-performance Motor. Motor Timer H2A 1 Motor Timer H2A Miniature, High-performance Motor Timer Employs high-reliability bifurcated contacts for output. Moving pointer provided in all types for confirmation of elapsed time. Employs time-out

More information

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm Emergency Stop Switch Mounting Aperture of 16 mm Modular construction, easy installation Positive opening mechanism with minimum contact separation of 3 mm in accordance with EN60947-5-1, Conforms to EN418

More information

Operation angle Return angle Output rating Operating voltage Model 40 to to VDC 2.4 to 3.6 VDC D6BN-1P

Operation angle Return angle Output rating Operating voltage Model 40 to to VDC 2.4 to 3.6 VDC D6BN-1P Micro Tilt Sensor D6BN Surface Mounting Tilt Sensor Fits Space- Confined Installations Low profile 2mm with Gull wing surface mount terminals Detect tilting over a range of 40 to 80 degrees in right-andleft

More information

MEMS Gauge Pressure Sensor

MEMS Gauge Pressure Sensor MEMS Gauge Pressure Sensor MEMS Gauge Pressure Senser Featuring Small Size and Low Power Consumption Ultra-miniature 6.1 4.7 8.2 mm (L W H). Superior electrical characteristics to capative type pressure

More information

Type Terminal Coil Contact form Model

Type Terminal Coil Contact form Model General Purpose Relay MK Exceptionally reliable general purpose relay. Long life (minimum 100,000 electrical operations) assured by silver contacts. Built-in operation indicator (mechanical, LED), diode

More information

Inductive Proximity Sensor

Inductive Proximity Sensor Inductive Proximity Sensor General-purpose Type in a Basic Switch Housing Mounting pitch compatible with that of mechanical basic switch. Wide operating voltage range: 10 to 30 VDC or 90 to 250 VAC. LED

More information

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models Long-barrel Inductive Proximity Sensor EE CSM_EE_DS_E Proximity Sensor with a Long Screw Length Increased tightening strength. Cable protectors provided as a standard feature. Increased indicator visibility.

More information

A165-E. Ordering Information. Emergency Stop Switch. For Panel Cutout of 16 mm

A165-E. Ordering Information. Emergency Stop Switch. For Panel Cutout of 16 mm Emergency Stop Switch For Panel Cutout of 16 mm H Modular construction, easy installation H Positive opening mechanism with a minimum contact separation of 3 mm in accordance with EN6947-5-1, for NC contacts

More information

Small Limit Switch D4V

Small Limit Switch D4V Small Limit Switch DV Compact Vertical Models Sized for Asian Standards Compact new design approximately / the size of OMRON vertical Limit Switches. Structure enables the terminal section to be fully

More information

Hinged Safety Door Switch

Hinged Safety Door Switch Hinged Safety Door Switch Polymer housing, IP65, and slow-action contacts with positive opening. Two actuator types are available: Shaft Arm lever Arm lever type can be adjusted to allow a right (180 ),

More information

Analog Input Terminal

Analog Input Terminal Analog Input Terminal I/O Interface Converts Analog Input Data into Binary Data Four inputs available. High resolution of 1/6000. Conversion is possible within a range of 5% to 105% FS. High conversion

More information

Power Contactor with Mirror Contacts

Power Contactor with Mirror Contacts LLAME SN COSTO Force-Guided Relays Power Contactor with Mirror Contacts Contents Selection Guide 2 Force-Guided Relays G7SA G7S- -E 3 8 Power Contactor with Mirror Contacts J7KNA-AR G7Z 11 15 1 LLAME SN

More information

AUTOMOTIVE LOW PROFILE MICRO-ISO/MICRO-280 RELAY

AUTOMOTIVE LOW PROFILE MICRO-ISO/MICRO-280 RELAY AUTOMOTIVE LOW PROFILE MICRO-ISO/MICRO-8 RELAY CV RELAYS (ACV) Micro ISO Form C type Micro 8 plug-in type Micro ISO Form A type Micro 8 PC board type Compliance with RoHS Directive FEATURES Low profile:.

More information

Sealed type washable 1C H-1C-C 812H-1C-V 812H-1C-S (SPDT) F 812H-1C-C F 812H-1C-V F 812H-1C-S F

Sealed type washable 1C H-1C-C 812H-1C-V 812H-1C-S (SPDT) F 812H-1C-C F 812H-1C-V F 812H-1C-S F 8H Type List 8H Terminal style Contact form Features Miniature PCB Power Relays A 2VAC. High CTI 2 material or product comply with IEC 33-1 are available. UL Insulation Class F. VDE, UL/CUL, TUV, CSA/CUS

More information

SG-B1 SERIES / SG-A1 SERIES

SG-B1 SERIES / SG-A1 SERIES 643 Door with Solenoid Interlock / Door Ultra-slim SG-B1 SERIES / SG-A1 SERIES Related Information General terms and conditions... F-7 General precautions... P.1501 PHOTO PHOTO Conforming to Machine &

More information

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from Omron STI Application Support Thank you for your interest in Omron STI products. Please contact Omron STI with your application questions. Support Engineers are available at our USA headquarters from 4:00

More information

RU Series Universal Relays

RU Series Universal Relays Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator available on plug-in relays No internal

More information

Selection Guide Automotive Relays

Selection Guide Automotive Relays Selection Guide Automotive Relays Classification Ultra-Miniature PCB Relay Model G8N1 G8ND2 G8NW Features Fully sealed construction Twin automotive relay Fully automated assembly suitable for polarity

More information

Ordering Information. MEMS Gauge Pressure Sensor 2SMPP. MEMS Gauge Pressure Sensor Featuring Small Size and Low Power Consumption

Ordering Information. MEMS Gauge Pressure Sensor 2SMPP. MEMS Gauge Pressure Sensor Featuring Small Size and Low Power Consumption MEMS Gauge Pressure Sensor 2SMPP MEMS Gauge Pressure Sensor Featuring Small Size and Low Power Consumption Ultra-miniature 6.1 4.7 8.2 mm (L W H). Piezo Resistive element provides electrical characteristics

More information

881WP. Type List. Ordering Information 881 WP1-1A C - - C Basic series designation 4. C -- Contact material AgNi

881WP. Type List. Ordering Information 881 WP1-1A C - - C Basic series designation 4. C -- Contact material AgNi Type List Terminal style WP (High power type, terminals)-.0mm pitch Contact form A (SPNO) Features Low Profile mm w/ fasten terminals. High Rating 7A 277VAC. High temperature withstand up to 2. UL/CUL

More information

G9SA-TH. Two-Hand Controller. Ordering Information. Specifications. 45-mm Wide Two-hand Control Circuit. H Two-hand Controller, easy-to-connect

G9SA-TH. Two-Hand Controller. Ordering Information. Specifications. 45-mm Wide Two-hand Control Circuit. H Two-hand Controller, easy-to-connect Two-Hand Controller -mm Wide Two-hand Control Circuit H Two-hand Controller, easy-to-connect Expansion Units available H Positive, force-guided contacts H DIN-rail mounting and panel mounting available

More information

General Purpose Relay

General Purpose Relay General Purpose Relay KML 15A switching capability 1.5kV dielectric strength (between coil and contacts) Various terminals available Socket available 1 to 3 pole configurations 1. COIL DATA (at 23 ) 1)

More information

A165S/W. Separate Construction with Cylindrical 16-dia. Body. Knob-type Selector Switch (Detachable) (Cylindrical 16-dia.

A165S/W. Separate Construction with Cylindrical 16-dia. Body. Knob-type Selector Switch (Detachable) (Cylindrical 16-dia. Knob-type Selector Switch (Detachable) (Cylindrical 16-dia.) CSM_A165S_W_DS_E_4_1 Separate Construction with Cylindrical 16-dia. Body Same separate construction as the A16-series Pushbuttons with Miniature

More information

Lighted PushButton Switch

Lighted PushButton Switch Lighted PushButton Switch Cylindrical 8mm dia. Subminiature Series Featuring Short Mounting Depth Round, square and rectangular LED pushbutton units. types also available. Requires only 18mm mounting depth.

More information

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9. Compact Interlock Safety Door Switch Compact Safety Switch Saves Space and is Ideal for a Variety of Doors Positive opening mechanism and double insulation approved by TÜV and BIA. Five-direction Operation

More information

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS 4 A CAPACITY, THE VARIETY OF CONTACT ARRANEMENT RELAY RoH Directive compatibility information http://www.mew.co.jp/ac/e/environment/ FEATURE 1. Compact with high sensitivity The highefficiency polarized

More information