Indicating Meter for Special Instrumentation. DEF-15S.D.W DEF-17S.W Indicating Meter for Instrumentation CAT.NO.EF-15,17,100N-02 DEF-15W DEF-17W
|
|
- Thomas Robbins
- 5 years ago
- Views:
Transcription
1 DEF-7W DEF-W DEf-NWT DEf-NST DEF-S.D.W DEF-7S.W Indicating Meter for Instrumentation DEf-N Indicating Meter for Special Instrumentation CAT.NO.EF-,7,N-
2 Contents Indicating Meters for Instrumentation DEF-S, DEF-W, DEF-7S, DEF-7W Features, Specifications and Ordering Guide... Outside / Dimensional Diagram... Scale Division Table, Measuring Point Entry Example, Tag No. Plate Entry Examples... Instruction Manual... Indicating Meter for Special Instrumentation DEf-N Features and Specifications...7 Main Part Materials and Processing...8 Outside / Dimensional Diagram...8 Connection Diagram...9 Input Signal and Internal Resistance...9 Usage Conditions... Performance... Instruction Manual ()... Instruction Manual ()... --
3 Indicating Meter for Instrumentation DEF-S (Single-pointer type) DEF-7S (Single-pointer type) DEF-W (Two facing pointers type) DEF-7W (Two facing pointers type) [Overview] This meter has the optimal structure and characteristics to function as an indicator for various process control systems such as power, petroleum, chemical, metal and paper plants. A state-of-the-art instrument panel receiver with an elegant, stately design and extensive functionality; this highly reliable product makes control station quality even higher. Features Comparative measurements for measurement control of series such as directed standard values and measurement values can be conducted with ease because the DEF - W and DEF - 7W are integrated in a pair meter structure. Optimal for system display panels and graphic monitoring panels. Appropriate for areas with dense instrumentation as very little space is required for installation. Two or more units can be neatly connected. Tag plates are attached to the top and bottom to display information such as measuring point name and tag number. The scale is brighter, larger and easier to read, making it easy to perform a series of control operations. Parts such as the zero-point adjuster and the scale plate can be replaced because the meter unit can be easily removed from the front side. 7 DEF-S only DEF-W only Specifications ) Direct-acting - Input signal is applied directly to the coil. Circuit System ) Electronic - Direct current amplification is performed for the input signal of the DC voltmeter and internal resistance is increased (DC voltmeter only). Input Signal Input Resistance DC ~ma Direct-acting Ω±% Electronic Input Signal and Input Resistance ~ma ~V ~V -~~+ Ω±% 8kΩ±% kω±% kω±% MΩ or above MΩ or above Inputs other than those indicated above can be manufactured upon request. Tolerance ±% (Dependent on maximum scale value or span) Scale Length type: mm 7 type: mm S: Single-pointer (Black) W: Two facing pointers (Black) 7 type: Lance-shaped tip knife edge, red coating is standard (Fluorescent) Scale Plate Thermal Behavior White base, black scale, black Less than % for degrees Auxiliary power supply is required for electronic DC voltmeters Voltage is DC V±V, approx. ma (per component) Influence of Variation of Auxiliary of Less than.% for % Electronic DC Voltmeter Ambient Temperature and Humidity - ~, %~8%RH Mounting Posture Perpendicular installation, vertical (Designate installation angles when mounting at an incline) Insulation Resistance More than MΩ at V mega (Between earth and input or power terminal) Dielectric Strength Face Casing Coating AC V for minute (/Hz) Standard: Black (7.BG/. available upon request) Weight S:. kg, D:. kg, W:. kg 7S:. 9kg, 7W:. kg Shape Dimensions Scale Division Tag Plate Entry Examples Other Affixed to the inside of the case (Material: tetrone film) According to P / P outside dimensions. According to P scale division table. According to P entry examples. According to JISC. DEF-7S DEF-7W DEF-S DEF-W Ordering Guide Model Name DEF-7S Direct-acting single-pointer (Left side only) DEF-S Direct-acting single-pointer (Left side only) DEF-7W Direct-acting double-pointer (Two facing pointers type) DEF-W Direct-acting double-pointer (Two facing pointers type) DEF-7S Electronic single-pointer (Left side only) DEF-S Electronic single-pointer (Left side only) DEF-7W Electronic double-pointer (Two facing pointers type) DEF-W Electronic double-pointer (Two facing pointers type) Input Signal Scale Specifications Coating Color Tag Plate Entry Characters Mounting Posture --
4 Outside / Dimensional Diagram DEF-S Direct-acting Single-pointer Meter and Electronic Single-pointer Meter Escutcheon Tag No. when sheets are displayed. N+. N is the connected quantity Panel Cutout Dimensions (7) (Rear Installation Space). () 8 M Screw Terminal Cover + LEFT - + LEFT - + DCV -. (Tag Plate) 8. 8max. Attachment Bracket (M) Tag No. Label Direct-acting Tag No. Label Electronic (with Amplifier) Input (Black pointer): (+).(-) Input (Black pointer): (+).(-) Auxiliary : DC V (+).(-) DEF-W Direct-acting Double-pointer Meter and Electronic Double-pointer Meter 8 Escutcheon Tag No. when sheets are displayed Panel Cutout Dimensions (7). N+. N is the connected quantity (Rear Installation Space). () 8 8 M Screw Terminal Cover DCV -. (Tag Plate) 8. DEF-W 8max. Attachment Bracket (M) { Relation of s to Terminal Symbols + - } Left side pointer (As viewed from front of meter) DEF-W + - } Right side pointer (As viewed from front of meter) Tag No. Label Electronic (with Amplifier) Input (Black pointer): (+).(-) Input (Red pointer): (+).(-) Auxiliary : DC V (+).(-) DEF-7S Direct-acting Single-pointer Meter and Electronic Single-pointer Meter Escutcheon l Panel Cutout Dimensions When connected: l=. n+. n is the connected quantity (8) (Rear Installation Space) 9 () M Screws + LEFT FULL SCALE ADJUSTER Terminal Cover + DCV - 9 (Tag Plate) max. Resistor for Sensitivity Adjustment Attachment Bracket (M) Direct-acting Electronic (with Amplifier) Terminal Symbol + DC V Auxiliary + Side - } - Side --
5 DEF-7W Direct-acting Double-pointer Meter and Electronic Double-pointer Meter Escutcheon l Panel Cutout Dimensions (8) (Rear Installation Space) When Connected: =.xn+. n is the connected quantity 9 () FULL SCALE ADJUSTER M Screw Terminal Cover + LEFT - + RIGHT DCV (Tag Plate) max. Resistor for Sensitivity Adjustment Direct-acting Electronic Attachment Bracket (M) Relation of s to Terminal Symbols (with Amplifier) + - } Left side pointer (As viewed from front of meter) + DC V Auxiliary + - } - } Right side pointer (As viewed from front of meter) Measuring Point Entry Examples Tag No. Plate Entry Example For Single-pointer For Double-pointer. 8.. Main Steam Pressure Setting Value Center Center Command Value Center Rate of Change Center -Stage Combustion CD M A X Aperture Aperture Setting Center Heavy Crude Oil Temperature Adjuster Actual Measured Value Center Up to four each Up to four each each Up to four each PY--A Character Height mm Up to 9 (.) As Requested 9 (.) As Requested () Values for type indicated between parentheses Unit: mm () Values for type indicated between parentheses Unit: mm --
6 [EF- Instruction Manual] (The zero-point adjuster and scale plate of the the DEF-S and DEF-W can be replaced simply by removing the meter unit from the front side.) [Removing the Meter] Stopper. Hook your finger on the bottom part of the name plate and pull it out. First the name plate comes out, then the meter unit comes out until it protrudes by approx. 7mm. At this point the clamping mechanism is released. The name plate will not come out any further, but be careful because the meter unit may pop out if it is facing downward.. The meter unit can be completely removed, but the last part has a stopper on it, so remove the unit by pulling up and towards yourself.. The meter unit and meter frame can be completely separated by pulling out the connector.. Insert the connector followed by the main unit to install the meter unit. After pushing in the meter unit part-way, push in the name plate, then push in the meter unit the rest of the way until you hear it lock into place with a click. The name plate and meter unit can be pushed into place in any order, but make sure afterwards that the meter unit does not come out when pulled on. Connector [Adjusting Zero-point] Maximum Scale Value Adjustment. Hook your finger on the bottom part of the name plate and pull it out. First the name plate comes out, then the meter unit comes out until it protrudes by approx. 7mm. At this point the clamping mechanism is released. The name plate will not come out any further, but be careful because the meter unit may pop out if it is facing downward.. Adjust zero-point after pulling the meter unit out into a position where the adjustment can be carried out. Adjust zero-point on the side face by turning the circular plate printed with [ZERO ADJ]. This is on the same side as the [ ] symbols in the same color as the pointer. Turn the plate using a screwdriver that fits inside the groove properly. Using an inappropriate size may break the groove.. After adjusting zero-point, push in the meter unit part-way, push in the name plate, then push in the meter unit the rest of the way until you hear it lock into place with a click. The name plate and meter unit can be pushed into place in any order, but make sure afterwards that the meter unit does not come out when pulled on. [Replacing the ] [Replacing the Scale Plate]. The upper name plate can be removed by hooking your finger around the upper part and pulling towards you.. The lower name plate can be removed by hooking your finger around the lower part and pulling it out, then pushing an object such as a screwdriver into the tab on the side and pulling out and towards you. It can be easily removed by simply pulling out one of the tabs.. Both the upper and lower nameplates can be attached by pushing them in.. Pull the meter unit out from the meter frame.. Take out the two screws and remove the cover.. Take out the two screws and replace the scale plate cassette.. Do not touch the pointer when attaching the cassette or cover. [For the EF-W] [Attaching the Meter]. Insert the meter from the front side of the panel.. Use the attachment brackets to fix the top and bottom of the meter in place from the back. Scale Plate Snap. Pull the meter unit out from the meter frame.. Take out the two screws and remove the cover.. Replace the left and right scale number plates () after removing the scale plate ().. Do not touch the pointer when replacing the cassette or attaching the cover. Scale Number Plate --
7 Indicating Meter for Special Instrumentation Model Name Format DEf-N Features This instrument panel meter can be densely mounted, enabling smaller panels. Standard product includes a set pointer. Multiple meters can be installed in a series. Terminals are separated for a configuration that protects against short-circuits. T Vertical Type Y Horizontal Type S Single-pointer W Double-pointer (Facing) Improved Model Meter Front Dimensions x mm DC Ammeter or Voltmeter (Including Reception Meter) Equipped with an escutcheon to protect against light leakage from the back face of the panel edges when installed in a series. Specifications Product Name Item Model Name Shape Dimensions Weight Specifications Edgewise Type Meter Vertical Type DEf-N ST DEf-N WT Horizontal DEf-N SY Type DEf-N WY Display xmm DEf-N ST(Y) DEf-N WT(Y) Note Vertical direction scale face with a single-pointer Vertical direction scale face with a double-pointer Horizontal direction scale face with a single-pointer Horizontal direction scale face with a double-pointer.kg or less.kg or less Operating Principles Movable Part Support Method Measurement Type Limit of Input Signal Cover color Movable coil Pivot support method DC voltage or current Minimum DC V or DC μa Maximum DC V or DC A Munsell N. (standard black). Class (Standard) If the input signal exceeds the maximum value, it will be routed to the series resistor or the externally attached shunt (Except in the DEf-N D, where up to V is built in.) Munsell 7.BG /. and N (gray) can be manufactured upon request. Class Vertical (Standard) Specify whether it will be installed on a flat or inclined surface. For inclined surfaces, specify the angle from a flat surface. Installation Location DEf-N ST (Y) Black lance shape (Standard) DEf-N WT (Y) Black lance shape (Standard) Wand-type or fluorescent color available upon request. In this case, the scale plate is flat. Red or fluorescent color available upon request. 7 Shape and Coating Color of Set Scale Length Scale / Colored Line or Band Mounting Includes Variable Resistance for Span Adjustment Included 7mm Single scale for single-pointer is standard; standard color for scale lines and numbers is black. Can be installed directly on panels with a thickness of mm or lower. to the back face of the meter in standard product. The meter cover can be removed and a movable set pointer can be installed upon request.. A double-scale is available upon request for the DEf-N ST (Y). In this case, the pointer is a rod and the scale plate is flat.. A colored line or band can be displayed on the scale upon request. A dedicated escutcheon is required to install multiple meters stacked in a series. (This is a standard accessory.) Rotate to the right to increase the value. -7-
8 Main Part Materials and Processing Part Name Material Processing Cover Base Lid Plastic Packaging Escutcheon Scale Plate Transparent polycarbonate (Fire-resistant) Polycarbonate resin (Fire-resistant) Sheet iron Black neoprene rubber Phosphor copper Colored aluminum board The resin surface has an anti-static finish processed by Colcoat Color is black Black, coated after chromate treatment Affixed to the lid with rubber glue Black coating or dependent on specifications Baked-on acrylic resin coating (White is standard) Lance Shape Aluminum board Black alumite treated pointer part Rod Aluminum pipe Organic fluorescent coating or black coating for needle tip Terminal Brass M screws installed in brass bar for mm product Yupo sticker paper (Display label) Tetrone film (FS ADJ.) Paper (Seal) Nickel plating with glue Outside / Dimensional Diagram ± M Terminal Screws.. M x Mounting Screws +.xn ± Escutcheon A n is the number of items. Escutcheon Outside Escutcheon B Standard Product Set % % % % % % % DEf-NWY DEf-NWT Outside dimensions diagram is the same as the above figure Blank DEf-NST Left Side Right Side DEf-NWT -8-
9 Connection Diagram Model Name Direct Measurement Ammeter With Externally Connected Shunt Direct Measurement Voltmeter With Externally Connected Series Resistor DEf-NST DEf-NSY Shunt Series Resistor Ammeter Ammeter Voltmeter Voltmeter + - DEf-NWT DEf-NWY Shunt Series Resistor Ammeter Voltmeter Amplifier Included Common to Each Type + - External Auxiliary Connect the terminals for,, and of the ammeter and voltmeter as shown in the above figure, then connect and to the external auxiliary power supply. Input Signal and Internal Resistance (Maximum Scale Value Unique to Meter) Voltmeter Input Signal Internal Resistance ~ mv Ω - ~ + V kω ~ V kω ~. V. kω ~ V kω ~ V kω ~ 7. V 7. kω ~ V kω ~ V kω ~ V kω ~ V kω ~ V kω ~ V kω ~ 7 V 7 kω ~ V kω ~ V kω ~ V kω ~ V kω ~ V kω ~ V kω ~ V kω ~ V kω ~ V MΩ Ammeter Input Signal Internal Resistance ~ μa kω ~ μa Ω ~ μa Ω ~ ma Ω ~ ma Ω ~ ma Ω ~ ma Ω ~ ma Ω ~ ma. Ω ~ 7 ma.8 Ω ~ ma. Ω ~ ma. Ω ~ ma. Ω ~ ma. Ω ~ 7 ma.8 Ω ~ A. Ω ~ A. Ω ~ A. Ω ~ A. Ω ~ ma ~ ma ~ ma ~ ma Ω Ω Ω. Ω Note. If the ammeters exceeds A, the product has a mv meter with an externally attached shunt.. If the voltmeter exceeds V, an externally attached series resistor is included. (Except for the DEf-ND meter, which has an externally attached series resistor when exceeding V.). Internal resistance of zero-center meters (a) The value for voltmeters is the same as for zero-left meters. (b) The sum maximum value for ammeters is the same as for the corresponding zero-left meter.. Shunts and series resistors can be externally attached upon request, even for the range of input signals on the left.. Tolerance for all internal resistance values is within ±%.. The meter which has an input signal of -V with a resistance of MΩ comes with an amplifier and requires a DCV auxiliary power supply.. Current consumption is ma for one circuit (ma for two circuits).. Specify the input signal and internal resistance value as an input signal of - V with a resistance of kω is optional. -9-
10 Usage Conditions Item Specifications Note Ambient Temperature Storage Temperature - C~+ C - C~+ C No stipulated temperature range for use of the JIS C. The cover warps at 8 C.. Anti-humidity processing can be applied upon request for environments with over 9% humidity. Ambient Humidity %~9%RH. Use a commercially available anti-static finish if using the product at % humidity or lower, as this humidity level will deteriorate the effectiveness of the cover's anti-static processing. Hazardous Gas Vibration Not included.g or below According to rules or against position Processing can be performed upon request to counteract low density caused by corrosive gases such as sulfuric acid gas. Installation Location indicated on meter Within degrees Warm-up External Magnetic Field Panel At least minutes after turning on meter Degree of geomagnetism As indicated on meter For Fe or NFe Performance Item Conditions Performance Standard Specification Value Note Tolerance Against maximum scale value Within ±.%. Percentage of the sum of the absolute value of the of upper and lower limits of the scale for zero-center meters. Percentage of the upper limit value of the effective measurement range for extended scales Adjustable Range of Variable Resistance Against maximum value ±% or above Friction Influence of Posture Zero Point Fault Response Time Overshoot Influence of Overheating Influence of Temperature Against scale length Against scale length Against scale length Time needed to reach / scale Scale overshoots / Against maximum scale value Against maximum scale value Within.% Within % Within.% sec. or below Less than % Within ±.% Within.% Influence of External Magnetic Field Continuous Overload Momentary Overload Against maximum scale value Against maximum scale value Within % ±.% Must not cause extreme thermal or mechanical breakage. An error will not be detected even if JIS C is overloaded by double. Insulation Resistance Voltage Test Shock Vibration Between terminal and case Between terminal and case Between terminals on double-pointer meters Friction Influence of Posture Tolerance Friction Influence of Posture Tolerance MΩ or above / Hz V for one minute / Hz V for one minute Within.% of scale length Within % of scale length Within maximum scale value ±.% Within.% of scale length Within % of scale length Within maximum scale value ±.% amplifier is V for minute (DEf-ND is V for minute) --
11 Instruction Manual () Item Instructions Diagrams and Examples Mounting () () () () () () Make mounting holes according to the panel cutout pictured in the outside dimensions diagram. The materials of the attached panel are as indicated on the label of the meter. An error within.% of the maximum value occurs when the panel materials are incorrect. Insert the escutcheons between the panel face and the meter's mounting area when installing the meter on the panel. Use Escutcheon A for the edge and B between meters when installing multiple units in tandem. Use the escutcheons to prevent the leakage of light from the underside of the panel due to gaps in the meter mounting. To install the meter onto the panel, first position the attachment bracket in the position of the thin line in the figure. Next, put the meter into the panel, loosen screw C, tighten C in the position of the thick line, then use setscrew D to affix the meter tightly to the panel face. A panel up to mm thick can be installed. Escutcheon A Escutcheon B Label Specification Fe NFe Escutcheon A Panel MAX. mm Panel Material Steel Panel Nonferrous Metal Panel Escutcheon B D C Be sure to check the zero-point of the pointer before passing an electric current through the meter. If the pointer is deviating, adjust it using the following procedure. () For meters with a value from to maximum, adjust the zero-point adjuster on the front by using a to.mm flat-head screwdriver to rotate the pointer left or right. () For meters without a scale (expanded scale meters), such as the - ma meter, apply electricity equivalent to the minimum scale value and adjust the zero-point adjuster by rotating the pointer left or right with a screwdriver to match the minimum scale value. () The relationship between the zero-point adjuster and the pointer is as listed in the table. Adjusting Zero-point Model Name DEf-NST DEf-NWT DEf-NSY DEf-NWY Left Right Blank Left Right Upper Lower Blank Upper Lower Left None Left (L) Right (R) Upper Lower None Upper (UPPER) Lower (LOWER) Edgewise Meter (T) Blank DEf-NST DEf-NWT DEf-NDT (B)... Black (R)... Red (UPPER)... Upper Side (LOWER)... Lower Side (L)... Left Side (R)... Right Side Horizontal Type (Y) Blank DEf-NSY DEf-NWY DEf-NDY --
12 Instruction Manual () Item Instruction Diagrams and Examples () A variable resistor for maximum value adjustment is installed on the back face of this meter and can be adjusted by rotating left or right with a flat-head screwdriver. The relationship between the pointer and the maximum adjuster is as indicated in the table when viewing the meter from the back face. Edgewise Meter (T) Maximum Value of Adjustment () () Model Name Maximum Adjuster DEf-NST DEf-NWT DEf-NSY DEf-NWY Lower Right None Lower Right Upper Left Upper Right None Upper Right Lower Left Left None Left (L) Right (R) Upper None Upper (UPPER) Lower (LOWER) Rotating to the right when adjusting will increase the pointer indication, while rotating left will decrease it. The adjustable range is approximately % or more of the maximum scale value. If an error is discovered, adjusting the maximum value with the zero-point adjuster will break down the linearity of the scale and result in overall error. In such cases, thoroughly investigate the source of the error and request repairs or replacement if the meter is the cause. Horizontal Type (Y) Scale Calibration () () () Terminal connection fittings are fastened with M- screws. Up to two connection fittings can be installed. A separation board is installed between each terminal to prevent contact by metal pieces in between the terminals of the meter or between those of the meter and those of adjacent meters, which could cause a short-circuit. The relationship between the pointer and the terminal layout is as indicated in the chart. Model Name Terminal Number and DEf-NST DEf-NWT DEf-NSY + DEf-NWY + + Amplifier Common to All Types + Left Left (L) Right (R) Upper Upper (UPPER) Lower (LOWER) Auxiliary Power Supply Edgewise Meter (T) Horizontal Type (Y) Scale Calibration () () Test tolerance according to the method in item when calibrating the scale during periodic inspections, etc. Regular periodic inspections should be carried out once every to months depending on frequency of operation. --
13 ~Promotion of Environmental Issues~ Our company is fully committed to not using hazardous materials in our products. All of our main products are manufactured without the use of the six hazardous materials prescribed in the RoHS directives. Please consult us about the compatibility of each product. Products that comply with the RoHS directives are distinguished by a label containing the "Ro" mark. Safety Precautions Only allow this product to be handled by people with sufficient knowledge and skill to ensure proper use. Carefully review any connection diagrams before soldering to ensure correctly soldered connections. Fully tighten screws. Loose screws may cause overheating or burnout. Mount the terminal cover after completing connections. Do not use if the specified rating is exceeded. Doing so may lead to malfunction or injury. Do not touch live parts of the product. Disconnect circuits during maintenance or inspections. ISO 9 Registration No. JSAQ 9 Main Office Sales Department Tokyo Office Nagoya Office Homepage Shimoshinjo -chome -ban 7-go, Higashi Yodogawa Ward, Osaka City, - TEL (9) FAX (8) Shin Yoshida Higashi 8-chome,7-ban 7-go, Kohoku Ward, Yokohama City, -8 TEL () 8~ FAX () 989 Nagoya SI Bld. F Nishiki -chome 7-ban -go, Naka Ward, Nagoya City, - TEL (9) 778 FAX (9) 778
Portable Instruments. Bulletin 2000-E
Portable Instruments Bulletin 2000-E Usage Precautions Warning: Indicates usage precautions that must be read to ensure the safety of users and the equipment. Safety Instructions for Portable Instruments
More informationSquare Shape Instrument - PK Series
Square Shape Instrument - PK Series PK-series is a square type meter. 4 difference degree type for this square PK-series:120mm, 100mm, 80mm & 60mm. Panel cut dimension is conformity with JIS C 1103. PK
More informationM Series 010.D Data Sheet. Analog Meters with Moving-Coil Movement, 90 Dial PSQ 48 PQ 72 RS PQ 96 RS PQ 144 RS
Data Sheet M Series 010.D.101.11 Analog Meters with Moving-Coil Movement, 90 Dial PSQ 48 PQ 72 RS PQ 96 RS PQ 144 RS Application The moving - coil panel meters PSQ 48 in a housing of moulded thermoplastic
More informationM Series 140.D Data Sheet. Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial RW 96 RP 96
Data Sheet M Series 140.D.101.06 RW 96 RP 96 Two-Point Controller with Moving-Iron or Moving-Coil Movement 90 Dial Application The two point controllers RW/RP 96 (M series) with one or two setpoints provide
More informationMEMS Gauge Pressure Sensor
MEMS Gauge Pressure Sensor MEMS Gauge Pressure Senser Featuring Small Size and Low Power Consumption Ultra-miniature 6.1 4.7 8.2 mm (L W H). Superior electrical characteristics to capative type pressure
More informationMANUAL NO E1.2 Published in Dec.2004 Revised in Aug LF Series Linear Variable Differential Transformer INSTRUCTION MANUAL
MANUAL NO. 20405E1.2 Published in Dec.2004 Revised in Aug. 2007 LF Series Linear Variable Differential Transformer INSTRUCTION MANUAL LF SERIES FOREWORD For safe operation... Thank you for using our LS
More informationOrdering Information. MEMS Gauge Pressure Sensor 2SMPP. MEMS Gauge Pressure Sensor Featuring Small Size and Low Power Consumption
MEMS Gauge Pressure Sensor 2SMPP MEMS Gauge Pressure Sensor Featuring Small Size and Low Power Consumption Ultra-miniature 6.1 4.7 8.2 mm (L W H). Piezo Resistive element provides electrical characteristics
More informationOrdering Information. MEMS Gauge Pressure Sensor 2SMPP. MEMS Gauge Pressure Sensor Featuring Small Size and Low Power Consumption
MEMS Gauge Pressure Sensor 2SMPP MEMS Gauge Pressure Sensor Featuring Small Size and Low Power Consumption Ultra-miniature 6.1 4.7 8.2 mm (L W H). Piezo Resistive element provides electrical characteristics
More informationPLATINUM SERIES SWITCHBOARD METERS
PLATINUM SERIES SWITCHBOARD METERS www.sifamtinsley.co.uk DATASHEET E471457 Multifunction Meters Transducers & Isolators PLATINUM SERIES SWITCHBOARD METERS Temperature Controllers Converters & Recorders
More informationOBE (On-Board Electronics) Type Direct Operated Linear Servo Valves (Size: 01 & 03) LSVG-01-EH-*-**-**-10, LSVG-03EH-*-**-**-10/1006
NO. 10 01E September 1, 2010 Public Relations Group Products Publicity Section Sales Administration Department Hamamatsucho Seiwa Bdg., 4-8, Shibadaimon 1-chome, Minato-ku, Tokyo 105-0012, Japan Tel: +81-3-3432-2113
More informationInstruction Manual. Digital Panel Meter Model 3126 CAUTION. Code Type of T/C Measuring Range Display Range Accuracy
Instruction Manual Digital Panel Meter Model 3126 I-01861 1. Preface Thank you for purchasing our digital panel meter 3126 series. Before use, read this manual carefully and thoroughly, and keep this manual
More informationChapter 9 Basic meters
Chapter 9 Basic meters Core Competency Units UEENEEE003B Solve problems in extra-low voltage single path circuits UEENEEE004B Solve problems in multiple path DC Circuits Essential Knowledge and Associated
More informationYOKOGAWA Supplies A Complete Line of Precise Panel Meters... RoHS compliant
YOKOGAWA Supplies A Complete Line of Precise Panel Meters... RoHS compliant Elapsed Time Meters Devices will match the frequency of AC power systems. Six-digit counters record hours, tenths of hours, minutes
More informationPressure sensor with built-in amplification and temperature compensation circuit
sensor with built-in amplification and temperature compensation circuit PS-A PRESSURE SENSOR (built-in amplification and temperature compensating circuit) NEW FEATURES 1. Contains built-in amplification
More informationITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa
5.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator X Series This product is only for blowing gas. This product does not have sufficient pressure control for other applications (driving,
More informationInductive Proximity Sensor
Inductive Proximity Sensor Subminiature Sensor Ideal for Narrow Mounting Space Grooved TL-G3D is ideal for high-speed pulse generator and high-speed revolution control. TL-Q2 and TL-Q5 save mounting space
More informationINSTRUCTION MANUAL MANOSTAR TRANSMITTER EMT1. RoHS READ THE INSTRUCTION MANUAL BEFORE USING. No. TR-EMT1-E08
RoHS READ THE INSTRUCTION MANUAL BEFORE USING INSTRUCTION MANUAL MANOSTAR TRANSMITTER No. TR--E08 1-2-,Nishi-shiriike-cho,Nagata-ku,Kobe,Hyogo 65-001 JAPAN TEL. +81(78)-61-6000 FAX. +81(78)-61-6020 INTRODUCTION
More informationPrinciples and types of analog and digital ammeters and voltmeters
Principles and types of analog and digital ammeters and voltmeters Electrical voltage and current are two important quantities in an electrical network. The voltage is the effort variable without which
More informationSIGMA SERIES DE METER
SIGMA SERIES DE METER Analogue Meters www.sifamtinsley.co.uk DATASHEET Issue 1.0 Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current
More informationPower Controller. (see note 1) 10 sec
Power Controller Single-phase Models EUN Series AC Power Controller with Phase-control System Allows Precise Temperature Control Models with Base-up and Soft-start Functions Available EH Series Phase Control
More informationDigital display Pressure range ON/OFF output Linear output Model
Slim Digital Pressure Sensor E8CB/ CSM_E8CB DS_E 1 with Built-in Microcomputer and Digital Display Withstands a of 9 kpa and highly reliable. Incorporates a two-turn adjuster ensuring easy setting. Be
More informationTOWA SEIDEN INDUSTRIAL CO., LTD.
INSTRUCTION MANUAL SOUNDING LEVEL METER MODEL: TLX-120AP/200AP Meanings of indications for safety used in this Instruction Manual are as follows. WARNING: Indicates that improper handling assumes the risk
More informationStandard Specifications. Model. Indication precision. Clear cover. Brass Mass (kg) Bourdon tube. Model (Standard) Model G (2) G27-10-R1
Pressure Gauge for General Purpose Series G5/G27 G5 G27 G5-0-0 G27-0- Be sure to read the precautions on page 663 for selection and mounting. Dimensions Port size () precision ±5% F.S. (Full span) Case
More information2-Color Display High-Precision Digital Pressure Switch
2-Color Display High-Precision Digital Pressure Switch Settings can be copied to up to 1 slave sensors at once. The settings of the master sensor can be copied to the slave sensors. Reduced setting efforts
More informationDifferential Pressure Transmitter
Specifications/Instructions Differential Pressure Transmitter General Model PY9000D is a differential pressure transmitter that uses a ceramic cantilever sensor. Deflection of the ceramic cantilever caused
More informationPressure Transmitter
Specifications/Instructions Pressure Transmitter General Model PY7100A pressure transmitter is a small pressure transmitter using a semiconductor strain gauge. It detects the pressure of chilled/hot water,
More informationBright illumination face and snap-action switching.
ø A2 Series ø10 A1 Series ø8 A8 Series A2 Series A1 Series A8 Series Bright illumination face and snap-action switching. See website for details on approvals and standards. Hole Size Model Function Degree
More informationTECHNICAL GUIDE FOR PROXIMITY SENSORS DEFINITIONS YAMATAKE PROXIMITY SENSOR CATEGORIES
TECHNICAL GUIDE FOR PROXIMITY SENSORS DEFINITIONS "" includes all sensors that detect the presence of a metallic object approaching the sensing face or near the sensing face without mechanical contact.
More informationDIN Panel Meters Long Scale
DIN Panel Meters Long Scale A range of 72mm and 96mm DIN style panel meters measuring all electrical parameters and featuring moving coil movements. All meters incorporate slide-in dials and terminal covers
More informationHow to Order. Nil. W Water-cooled refrigerator type. Temperature: 5 to 40 C, Humidity: 30 to 70%RH Clean water 5 to /1.
Thermo-cooler Series HRGC Specifications HRGC//5 Cooling method Refrigerant Control method Ambient temperature/humidity Circulating fluid Note ) Temperature range setting Note ) C Cooling capacity Note
More informationHS1C-P Interlock Plug Unit with Door Lock
HSC-P Unit with Lock Interlock plugs with door lock mechanism for high level safety management. Installing the actuator on the guard door and the interlock switch on the machine, the guard door can be
More informationEVERLIGHT ELECTRONICS CO., LTD.
Features Side view white LED White SMT package Lead frame package with individual 2 pins Wide viewing angle Soldering methods: IR reflow soldering Pb-free The product itself will remain within RoHS compliant
More informationLife PERFORMANCE Catalog listing Standards Structure Electrical performance Mechanical performance Ambient operating conditions Recommende tightening
SPATTER-GUARDED SWITCHES Model LS Effective countermeasures against the adhesion of spatter. UL/CSA/GB(CCC marking)-approved. (excluding some models) ORDER GUIDE Actuator Name Roller lever type Shape Max.
More informationø8 A8 Series Miniature Control Units
A8 ø8 A8 Series Miniature Control Short 22-mm-long body miniature control unit series with LED illumination face and snap-action switching. Bright and clear LED illumination. All series have terminals
More informationTechnical Data Sheet Sigma Series DS Meter
Technical Data Sheet Sigma Series DS Meter The moving coil panel meters, DS 48/72/96/144 housed in moulded polycarbonate cases are suitable for the measurement of DC currents and voltages. These instruments
More informationCentury Style Analog Panel Meters
UL Recognized File # E91015 Except for the Wattmeters and Frequency Meters Glass window for optimum viewing Rugged black plastic case Black knife-edge pointer for precision reading The Specifications &
More informationAcceleration Sensor AS - 030
Acceleration Sensor AS - 030 1 Application The acceleration sensor AS-030 is used for measurement of vibration acceleration. 12 38 ø21,6 SW 22 M8; 6mm deep AS030-1 (020201) 2 Measuring Principle Acceleration
More informationRoHS Compliant READ THE INSTRUCTION MANUAL INSTRUCTION MANUAL ,Nishi-shiriike-cho,Nagata-ku,Kobe,Japan TEL: FAX:
RoHS Compliant READ THE INSTRUCTION MANUAL INSTRUCTION MANUAL MANOSYS PRESSURE TRANSMITTER EMT1 TR-EMT1-E06 653-0031 1-2- 3,Nishi-shiriike-cho,Nagata-ku,Kobe,Japan TEL078-631-6000 FAX078-631-6020 Ⅰ. SPECIFICATIONS
More informationSmart Look Series Meter
File No. E471457 Technical Data Sheet Smart Look Series Meter 1/2 The moving iron & moving coil panel meters sizes 2 " 1/2, 3 " are housed in a moulded polycarbonate cases which are suitable for the measurement
More informationELECTRICAL MEASURING INSTRUMENT CHAPTER 15 ELECTRICAL MEASURING INSTRUMENTS THE MOVING COIL GALVANOMETER The moving coil galvanometer is a basic electrical instrument. It is used for the detection or measurement
More informationHEAVY DUTY POWER RELAYS FEATURES
VDE VC HEAVY DUTY POWER RELAYS VC RELAYS Faston terminal Screw terminal mm 9 FEATURES VC power relays are designed for controlling heavy duty loads safely: Contact gap of 3 mm or more -point contacts for
More informationHS1C Interlock Switches with Solenoid
HSC es with The guard door remains locked until the machine stops completely. With the actuator mounted on the guard door and the interlock switch on the machine, the door is mechanically locked when closed.
More informationLED Annunciator Lights. KFE-HD Series
LED Annunciator Lights KFE-HD Series KFE-24HD KFE-11HD KFE-13HD Features A variety of lighting areas, ranging from 8 34mm to 18 42mm are available. Five vivid lighting colors are available: milky white,
More informationVoltmeter and Ammeter Design
EEE3406 Instrumentation & easurements LABOATOY Experiment 2 Name Class Date Class No. arks Voltmeter and Ammeter Design Objectives: After completing this lab, you will be able to measure the full-scale
More informationChapter 28. Direct Current Circuits
Chapter 28 Direct Current Circuits Direct Current When the current in a circuit has a constant magnitude and direction, the current is called direct current Because the potential difference between the
More informationOrdering Information. Text Surface-Mounting Signal Relay G6K
Surface-Mounting Relay with the World s Smallest Mounting Area and a Height of Only 5.2 mm ROHS compliant. Sub-miniature model as small as 5.2 (H) x 6.5 (W) x 10 (L) mm is ideal for high-density mounting.
More informationSPECIFICATION FOR ALUMINUM ELECTROLYTIC CAPACITOR
2016.4.29 SPECIFICATION FOR ALUMINUM ELECTROLYTIC CAPACITOR 1. PRODUCT 2. Part Number 3.CUSTOMER ST/SI TYPE ALUMINUM ELECTOLYTIC CAPACITOR UWP2G151KR035K (400v 150uF 30*35mm 105C 2000H) GD Rectifiers.
More informationModel Number Structure
Long-life Two-circuit Limit Switch WLM@ New Long-life Limit Switches Added to the Wide Variety of WL Models Improved resistance to abrasion and smoother movement in the head section means that a mechanical
More informationModel Number Structure. Power Controllers G3PX. Single-phase Models. Model Number Legend
Power Controllers GPX Refer to Safety Precautions (page 0). Single-phase Models EUN Series AC Power Controllers with Phase-control System Allow Precise Temperature Control Models with Base-up and Soft-start
More informationElectric Cylinder. LZB/LZC Series. It can be operated like an air cylinder. LZB Series. LZC Series LEF LEJ LEL LEM LEY LES LER LEH 25A- LEC
Electric Cylinder LZB/LZC Series It can be operated like an air cylinder. LZB Series LZC Series Model LZB LZC Max. thrust Max. speed 196 N 0 mm/s Lead screw Slide screw: ø8, ø Lead: 2, 6, Stroke 25, 40,
More informationInductive Proximity Sensor
Inductive Proximity Sensor General-purpose Type in a Basic Switch Housing Mounting pitch compatible with that of mechanical basic switch. Wide operating voltage range: 10 to 30 VDC or 90 to 250 VAC. LED
More informationTRIPLETT. Model 310 Type C Type 9. Test Equipment Depot Washington Street, Melrose, MA TestEquipmentDepot.
TRIPLETT Model 310 Type 9 310-C Type 9 Test Equipment Depot - 800.517.8431 99 Washington Street, Melrose, MA 02176 TestEquipmentDepot.com TABLE OF CONTENTS SAFETY RULES... 2 INTRODUCTION...8 SPECIFICATIONS...
More informationInnovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual
Innovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual 11-M61E TABLE OF CONTENTS HANDLING & MAINTENANCE Storage 1 Transport 1 STANDARD ENVIRONMENT 1 INSTALLATION AND CONNECTION
More informationG6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information
with the World s Smallest Mounting Area Subminiature model as small as.2 (H). (W) (L) mm is ideal for high-density mounting ((U)-2F(-Y)). Low profile of.2 mm improves mounting efficiency ((U)-2F(-Y)).
More informationMODEL: PSN3. Final Control Elements. STROKE 6: 0 to 60 mm (0 to 2.36 )
Final Control Elements SERVO-TOP II ELECTRONIC ACTUATOR (linear type; max. thrust 5000 N) Functions & Features Control valve actuator drive I to I positioner incorporated Lightweight, compact design High
More informationACTIVAL Motorized Three-Way Valve with Flanged-End Connection (JIS 10K / FC200)
Specifications/Instructions ACTIVAL Motorized Three-Way Valve with Flanged-End Connection (JIS 10K / FC200) General ACTIVAL Model VY54X0F is a series of motorized three-way valves with flanged connection.
More information* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue.
Authorised Distributors:- ASH & ALAIN INDIA PVT LTD S-, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-(India) Tel : -7977 Fax : -7977 E-mail : sales@ashalain.com Sensor Four-Input-Channel Sensor
More informationPHYSICS MCQ (TERM-1) BOARD PAPERS
GRADE: 10 PHYSICS MCQ (TERM-1) BOARD PAPERS 1 The number of division in ammeter of range 2A is 10 and voltmeter of range 5 V is 20. When the switch of the circuit given below is closed, ammeter reading
More informationOM Field-Type I/P Converter Model : KUX113 User's Manual
OM2-5900-1130 Field-Type I/P Converter Model : KUX113 User's Manual Copyright, Notices and Trademarks 1994-2012 Azbil Corporation All Rights Reserved. While this information is presented in good faith
More informationMA04X, MA06X ±1%, ±5%, Convex Type General purpose chip resistors array
MA04X, MA06X ±1%, ±5%, Convex Type General purpose chip resistors array Size 0402x4, 0603x4 (8p4R) ( Automotive & Anti-sulfur ) Page 1 of 8 MA04/ 06_V03 Apr.2010 FEATURE 1. High reliability and stability
More informationCOMPACT BUT CUT OFF DC POWER CURRENT, POWER CAPSULE CONTACT RELAY
COMPACT BUT CUT OFF DC POWER CURRENT, POWER CAPSULE CONTACT RELAY EB RELAYS (AEB) (1A type) FEATURES Compact and high capacity using double contacts in series and permanent magnet installed. (1,A/3 times)
More informationSPECIFICATION SHEET. ±1%, ±5%, Convex Type General purpose chip resistors array
SPECIFICATION SHEET CNA24, CNA34 ±1%, ±5%, Convex Type General purpose chip resistors array Size 0402x4, 0603x4 (8p4R) ( Automotive & Anti-sulfur ) All data in this sheet are subject to change, modify
More informationHS1E Series Full Size Solenoid Locking Switches
HS1E Series Full Size Solenoid Locking Switches AS-Interface Safety at Work Barriers Enabling Switches Door Interlock Switches X Series E-Stops Overview HS1E features: Basic unit and solenoid unit in one
More informationRU Series Universal Relays
Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator available on plug-in relays No internal
More informationWide-Vue Analog Panel Meters
UL Recognized - File # E91015 Except for the Wattmeters & Frequency Meters Clear acrylic window for wide viewing area Rugged black plastic case Black spade pointer for easy distant reading Optional: Behind-panel
More informationPRODUCT SPECIFICATION
1.0mm Pitch ZIF FPC Page 1 Top Entry Side Entry 1.0mm Pitch ZIF FPC Page 2 1.0 SCOPE. This specification covers performance, tests and quality requirements for 1.0mm Pitch ZIF FPC Connector 2.0 APPLICABLE
More informationInstruction Manual. Coating Thickness Gauge. Optionally with Memory
Instruction Manual Coating Thickness Gauge 1500 Optionally with Memory 1 Introduction The QNix 1500 is a part of the product line of non-destructive coating thickness measurement gauges manufactured by
More informationMULTISTAGE MICRO EJECTORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution
ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS MULTISTAGE MICRO EJECTORS CONTENTS MED07-E, MED10-E Series Specifications 715 Order Codes 716 Operation Principle
More informationMounting and operating instructions EB 5801 EN. Electric Actuators Type 5801 (Rotary Actuator) Type 5802 (Linear Actuator)
Electric Actuators Type 5801 (Rotary Actuator) Type 5802 (Linear Actuator) Linear Actuator with Type 3260 Control Valve Rotary actuator with lever system Linear actuator with Type 3321 (V2001) Control
More informationInstruction manual. High voltage insulation resistance tester KEW3121B/3122B
Instruction manual High voltage insulation resistance tester KEW3121B/3122B Contents 1. Safety warnings... 1 2. Features... 5 3. Specification... 6 4. Instrument layout... 9 5. Getting started... 10 5-1
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V
Description Single and two pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast magnetic only or hydraulically delayed switching characteristics
More informationOPERATING INSTRUCTION
11/05 Form #271 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 OPERATING INSTRUCTION Visit us at www.testequipmentdepot.com MODEL 3132 ANALOG INSULATION-CONTINUITY TESTER
More informationLAB 7. SERIES AND PARALLEL RESISTORS
Name: LAB 7. SERIES AND PARALLEL RESISTORS Problem How do you measure resistance, voltage, and current in a resistor? How are these quantities related? What is the difference between a series circuit and
More informationHS1E Series Full Size Interlock Switch with Locking Solenoid
HS1E Series HS1E Series Full Size Interlock Switch with Locking Solenoid HS1E Key features include: Basic unit and solenoid unit in one housing Plastic Housing: Light weight Ease of Wiring: All the terminal
More informationInsertion Thermostat
Specifications/Instructions Insertion Thermostat General Models TY6800Z and TTY6800Z are insertion thermostats applicable to control temperature (twoposition) for air in duct and liquid in tank or pipe.
More informationTechnical Data Sheet Chip LED with Bi-Color(Multi-Color)
Technical Data Sheet Chip LED with Bi-Color(Multi-Color) Features Package in 8mm tape on 7 diameter reel. Compatible with automatic placement equipment. Compatible with infrared and vapor phase reflow
More informationACTUATORS GENERAL CATALOG
CAD drawing data catalog is available. ACTUATORS GENERAL CATALOG ROTARY ACTUATORS VANE TYPE SERIES CONTENTS RAN (Standard Type) Basic Model and Configuration 259 Specifications 26 Order Codes 264 Dimensions
More informationSize 1206, 1210, 0805, 0603, 0402 (Anti-Sulfuration )
SR12, SR10, SR08, SR06, SR04, General purpose chip resistors Size 1206, 1210, 0805, 0603, 0402 (Anti-Sulfuration ) *Contents in this sheet are subject to change without prior notice. Page 1 of 9 ASC_SR_V03
More informationTOL-32EUG3W9-A. LED Lamp 2015/04/14 DL2EF3YG103-N J.F.FENG J.F.FENG Q.Y.HUANG
TOL-32EUG3W9-A LED Lamp 2015/04/14 DL2EF3YG103-N J.F.FENG J.F.FENG Q.Y.HUANG REV.: A-1 Prepared by J.F.FENG Released Date: 2015/4/15 Doc No : GL1412001 Page 1/7 TOL-32EUG3W9-A Lamp LED Part Number Material
More informationSeries 10-ZSE40A(F)/10-ISE40A
Series 10-ZSEA(F)/10-ISEA RoHS 2-Color Display High Precision Digital Pressure Switch How to Order For positive pressure Clean series For vacuum/ compound pressure 01 N01 W1 10 Rated pressure range ISEA
More informationMEMS Air Velocity Sensor D6F-W. Application Examples. Ordering Information
MEMS Air Velocity Sensor Compact, intelligent sensors featuring MEMS precision technology for repeatable airflow detection. Precision uni-directional air velocity detection. Integral passive Dust Segregation
More informationSeries ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE
High Precision, 2-color Display Digital Pressure Switch Series SE30/ISE30 SE ISE PSE I SE3 PS I SE 1 2 SP ISA2 IS SM PF2 IF Data With One-touch fittings are newly introduced. Straight type Elbow type 16-2-1
More informationData sheet FIXED THICK FILM CHIP RESISTORS; RECTANGULAR TYPE & ANTI-SULFURATION. AEC-Q200 qualified. RoHS COMPLIANCE ITEM Halogen and Antimony Free
No.: RMNW K HTS-1 /3 Date: 217. 4. 21 Data sheet : ANTI-SULFURATION RMNW1,16,2,32,35 AEC-Q2 qualified RoHS COMPLIANCE ITEM Halogen and Antimony Free Note: Stock conditions Temperature: +5 C +35 C Relative
More informationWide-Vue Analog Panel Meters
UL Recognized - File # E91015 Except for the Wattmeters & Frequency Meters Clear acrylic window for wide viewing area Rugged black plastic case Black spade pointer for easy distant reading Optional: Behind-panel
More informationAutomotive Grade Thin Film Chip Resistors
FEATURES PRECISE TOLERANCE AND TEMPERATURE COEFFICIENT EIA STANDARD CASE SIZES (0402 ~ 2512) AEC-Q200 QUALIFIED FOR AUTOMOTIVE APPLICATIONS LOW NOISE, THIN FILM (NiCr) CONSTRUCTION TEMPERATURE RANGE -55
More informationWARNING WARNING. ECM3000 Control Motor User's Manual CAUTION NOTICE SAFETY PRECAUTIONS
CP-UM-306E ECM3000 Control Motor User's Manual WARNING Be sure to turn the power OFF before mounting, removing, or wiring the ECM3000 or opening the cover. Touching electrically charged parts such as power
More informationFree position locking flat and compact cylinder UFCD Series
Space-saving cylinder ensures safety during work in power failures or accidents. Free position locking flat and compact cylinder UFCD Series Free position locking flat and compact cylinder UFCD Series
More informationCONDUCTIVE POLYMER ALUMINUM SOLID CAPACITORS
CONDUCTIVE POLYMER ALUMINUM SOLID CAPACITORS FEH Series Radial Lead, 125 C Low CUSTOMER APPROVAL : *Contents in this sheet are subject to change without prior notice. 1. Features Ultra Low & high ripple
More informationOD-KIT. Table of Contents. Precautions...2 Cautions Before Assembly...3 Tools to prepare...3 Checking the parts...3 Parts and materials...
2018 OD-KIT EJ 1 This kit is intended for those who have experience building electronic kits and who have a basic understanding of soldering and electronic parts. If you make a mistake during assembly,
More informationThermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar
Pressure Transmitter Type FM40466 General application Pressure transmitters are used to measure the relative (gauge) and absolute pressures in liquids or gases. The measuring device for the transmitter
More informationOrdering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31
Snap Action Switch Subminiature Snap Action Switch Switches 3 A loads (general-purpose), 1 A loads (low force general-purpose) and 0.1 A loads(microvoltage/ microcurrent) Long life span assured by high-precision
More informationTactile Switch. Ordering Information. A Wide Range of Models: 6 x 6 mm, 12 x 12 mm, Vertical, and High-force.
Tactile Switch A Wide Range of Models: 6 x 6 mm, 1 x 1 mm, Vertical, and High-force. A positive click action plus a long life equal to that of a no-contact switch. Radial models (taping specifications)
More informationDoor Interlock Switches
HSE Series HSE Series Full Size Locking Switches Overview X Series E-Stops HSE features: Basic unit and solenoid unit in one housing Plastic Housing: Light weight Ease of Wiring: All the terminal screws
More information2-Color Display High-Precision Digital Pressure Switch
2-Color Display High-Precision Digital Pressure Switch Series ZSE3/ISE3 2-color digital display allows you to choose the setting according to your application requirements. 4 different display settings
More informationor 0.5Ω whichever is greater (152 only) Temperature Coefficient of Resistance MODEL 152 MODEL 159 Refer to standard
Model 152, 159 FEATURES Rugged, High-Quality, All Metal Housing Short Length Behind Panel (11/32 ) Choice of Two Elements for Broad Resistance Range- 5Ω to 2MΩ No Glued Joints Extra Taps AVAILABLE High
More informationonlinecomponents.com
COMPCT CONNECTOR TERMINL FOR REDUCED WIRING CT-2 CONNECTOR TERMINL ORDERING INFORMTION TYPES RoHS Directive compatibility information http://www.mew.co.jp/ac/e/environment/ CT2: CT-2 connector terminal
More informationACTIVAL Motorized Two-Way Valve with Flanged-End Connection (Spring Return Type Actuator) (JIS 10K-FC200, -SCS13A)
Specifications/Instructions ACTIVAL Motorized Two-Way Valve with Flanged-End Connection (Spring Return Type Actuator) (JIS 10K-FC200, -SCS13A) General ACTIVAL Models VY51XXK and VY51XXH are series of motorized
More informationChapter Page. 1 Introduction Description 1
Chapter Page 1 Introduction 1 1.1 Description 1 Table of Contents 2 Calibration 3 2.1 Wet Calibration 3 2.2 Calibration Procedure 4 2.3 Installing Optional Display Board 5 2.4 Display Board Range Adjustment
More informationANSI Switchboard Meters
ANSI Switchboard Meters High quality range of switchboard instruments with Class 1 accuracy and which complies with American ANSI-C39.1 (1981) specifications. Available in 4 1 /2" case size, the rugged
More informationRead and understand this manual for safely usage.
TS02-0180 INSTRUCTION MANUAL FOR AIR BUBBLER SYSTEM LEVEL MEASUREMENT MODEL:LA100 MODEL:LA110 MODEL:LA1000 Read and understand this manual for safely usage. This manual describes the product of standard
More information