RoHS Compliant READ THE INSTRUCTION MANUAL INSTRUCTION MANUAL ,Nishi-shiriike-cho,Nagata-ku,Kobe,Japan TEL: FAX:

Size: px
Start display at page:

Download "RoHS Compliant READ THE INSTRUCTION MANUAL INSTRUCTION MANUAL ,Nishi-shiriike-cho,Nagata-ku,Kobe,Japan TEL: FAX:"

Transcription

1 RoHS Compliant READ THE INSTRUCTION MANUAL INSTRUCTION MANUAL MANOSYS PRESSURE TRANSMITTER EMT1 TR-EMT1-E ,Nishi-shiriike-cho,Nagata-ku,Kobe,Japan TEL FAX

2 Ⅰ. SPECIFICATIONS OF MANOSYS PRESSURE TRANSMITTER EMT1 Types Pressure range code EMT1 A 0 FM D 100 (example) Pressure range Max. value of scale Unit Pipng connector Output Type D E FV FM A B Pa kpa For vinyl or plastic tube For metal tube Two wires method from 4 to 20 ma DC Four wises method from 4 to 20 ma DC Four wises method from 0 to 1 ma DC Four wises method from 0 to 5 V DC Four wises method from 1 to 5 V DC Drip-proof indoor-use type Exposed terminal connection type Pressure ranges and characteristics Pressure range codes Pressure ranges Accuracies (at 20 ) 1 Temperature characteristics (zero + span) from 0 to 40 Withstanding pressures of pressure receiving element (refer to p.10) Pa, kpa D 10 0 ~ 10 Pa D 15 0 ~ 15 Pa D 20 0 ~ 20 Pa ± 2 % FS ± 0. 2 % FS/ D 30 0 ~ 30 Pa D 50 0 ~ 50 Pa D 75 0 ~ 75 Pa D ~ 100 Pa 10 kpa D ~ 150 Pa D ~ 200 Pa D ~ 300 Pa D ~ 500 Pa D ~ 1000 Pa E 2 0 ~ 2 kpa ± 1 % FS ± 0. 1 % FS/ E 3 0 ~ 3 kpa E 5 0 ~ 5 kpa 40 kpa E 10 0 ~ 10 kpa E 20 0 ~ 20 kpa E 30 0 ~ 30 kpa E 50 0 ~ 50 kpa 100 kpa E ~ 100 kpa 150 kpa D +-10 D +-20 D +-30 D +-50 D D D D D E +-2 E +-3 E ~ +10 Pa -20 ~ +20 Pa -30 ~ +30 Pa -50 ~ +50 Pa -100 ~ +100 Pa -200 ~ +200 Pa -300 ~ +300 Pa -500 ~ +500 Pa ~ Pa -2 ~ +2 kpa -3 ~ +3 kpa -5 ~ +5 kpa ± 2 % FS ± 0. 2 % FS/ ± 1 % FS ± 0. 1 % FS/ 10 kpa 20 kpa

3 Pressure measuring method Gas to be measured Pressure receiving element Measuring differential pressure Air or non-corrosive gas (not liquid) Diaphragm (silicon rubber) Withstanding pressure of instrument body 500 kpa (refer to p.10) Standard installation position Upward horizontal (0 ± 5 ) Conversion method of electric signal Output and transmission method Variable inductance 1. Two wires method Output signal from 4 to 20 ma DC (load resistance 500 Ω or less) Power supply voltage 24 V DC ± 10% (ripple Within 0.2 V P-P) Insulation resistance 2. Four wires method Output signal from 4 to 20 ma DC (load resistance 500 Ω or less) 0 to 1 ma DC (load resistance 5 kω or less) 0 to 5 V DC (load resistance 10 kω or more) 1 to 5 V DC (load resistance 10 kω or more) Power supply voltage 100 V AC ± 10 % 50 / 60 Hz Approximately 2 VA Between each terminal and case 20 MΩ or more (500 V DC megger) Medium and ambient temperature 0 to 50 (no freezing ) Ambient humidity 90 % RH or less (no dewing) Withstanding vibration 5 to 10 Hz Amplitude 10 mm, 10 to 50 Hz Acceleration 39 m / s 2 (each two hours on triaxial directions) Withstanding impact 100 m / s 2 (each two hours on triaxial directions) Material of the outer case Aluminum die-cast, Painted outer case surfaces (paint color gray) Applicable piping Piping connector polarity 1. Vinyl, plastic or rubber tube (I.D. 6) Applicable model attached with piping connector for vinyl or plastic tube 2. Metal tube (O.D. 6 ± 0.1) Applicable model attached with piping connector for metal tube 3. Hard plastic tube (O.D. 6 I.D. 4) Optional inner sleeve set (XIN 6 4 ) is needed for type attached with piping connector for metal tube. "HIGH" is marked on high pressure side and "LOW" on low pressure side. Mass EMT1A Approximately 1100 g EMT1B Approximately 960 g Accessory Nil Conformed standards RoHS Directive (2002/95/EC) (Products in compliance with the RoHS carry G or [[G]] mark on the label of product itself and on each package.) Caution For flammable gas, be sure to provide by intrinsically-safe system. (EMT1H S) 2

4 Ⅱ. OUTLINE DRAWING EMT1A (drip-proof indoor-use type) EMT1B (exposed terminal connection type) φ 5 installation long holes φ 5 installation long holes ± ± φ 5 holes or 4 M4 holes tapped Panel cut size ± 0.3 G 1/2 internal thread M4 terminal screws 4 φ 5 holes or 4 M4 holes tapped Panel cut size LOW HIGH 32 φ ± 0.3 LOW HIGH Ⅲ. ELECTRONICS CIRCUIT BLOCK DIAGRAM Two wires method Four wires method Span set Zero set Span set Zero set Piping connector (H) Amplifying Wave detection Linearizer Out put Oscillation 4 to 20mA DC External connection instrument Power supply DC 24 V E Current check terminal (4 to 20mA DC) Piping connector (H) Amplifying Wave detection Linearizer Out put Oscillation Power supply 4 to 20mA DC 0 to 1mA DC 0 to 5V DC 1 to 5V DC External connection instrument No power supply needed for Manosys Transmitter E 100V AC 50/60Hz power supply input Piping connector (L) Diaphragm Grounding Piping connector (L) Diaphragm PT Grounding 3

5 Ⅳ. EXTERNAL CONNECTION DIAGRAM Two wires method Check terminal from 4 to 20 ma Four wires method Power supply AC 100 V 50 / 60 HZ EMT 1 Grounding EMT 1 Grounding to 20 ma Power supply DC 24 V to 20 ma 0 to 1 ma DC 0 to 5 V DC 0 to 5 V DC Receiving equipment Receiving equipment Two wires method Manosys transmitter receives 24V DC power supply from outside and using power supply wiring, transmits 4 to 20mA DC signal to external receiver units. Note Manosys receiver is equipped with DC power supply for two wires method Manosys transmitter, therefore,in using combination with Manosys receiver, there is no need of the DC power supply equipment which is separately available. Two wires method Manosys transmitter can monitor output signal during operation, if they are connected with ampere meter with internal resistance of less than 10Ω to check terminal. Be careful about connection of two wires method Manosys transmitter and four wires method Manosys transmitter as see figures they are reverse in terms of current flow. Four wires method Manosys transmitter, which receives 100V AC power supply, generates 24V DC inside transmitter to work transmitting output signal to external receives. Transmission output diagram (differential pressure - output signal) For single pressure range For zero center range For single pressure range For zero center range Output signal (ma) 20mA(5V) 12mA(3V) 4mA(1V) Output signal (ma) 1mA(5V) 0.5mA(2.5V) 0mA(0V) Pressure (% FS) Pressure (% FS) Ⅴ. INSTALLATION AND TRIAL RUNNING 1. Installation Install this instrument at horizontal position (inclination angle at 5 ). If installation surface is vertical, use the installation bracket on vertical wall to install horizontally. (refer to p.8) Take the space of 0.5 m above the transmitter for the purpose of adjustment and maintenance. Do not install the instrument outdoors directly. If you need to get it installed outdoors directly, store the instrument at the storage casing with dew-proof construction. Avoid using where the instrument is subject to vibration, big impact and high humidity. Do not use at the place where corrosive gas (such as sulfuric gas and ammonia gas etc.) is present. Try to use the instrument away as far as possible from intensified power source and the unit generating high frequency (high frequency welder and high frequency sewing machine etc.). The instrument is not designed for measurement of combustible gas and installation where explosive danger risk area (hazardous area) exists. For flammable gas, be sure to provide by intrinsically-safe system (EMT1H S). 4

6 2. Pressure of measurement and connection of piping a) Measurement of positive pressure Connect the tube to the high pressure side piping connector (indicated by red color or letter H). The lower pressure port (blue or L) should opened to atmosphere, but do not remove the piping connector. b) Measurement of negative pressure Connect the tube to the low pressure side piping connector (blue or L). The high pressure port (red or H) should be opened to atmosphere, but do not remove the piping connector. c) Measurement of differential pressure Connect the tube from the high pressure piping connector to the high pressure port (red or H) and from the low pressure piping connector to the low pressure port (blue or L). Caution Measurement of single pressure using an instrument with zero point center range. Connect the tube to the high pressure side piping connector (red or H). In this case again, leave the piping connector attached to the low pressure side, which is opened to atmosphere. The single pressure is as displayed on a zero point center scale (+-). 3. Caution of piping a) Prohibition of common piping Piping each of pressure detectors and pressure receiving instruments tube exclusively dedicated for it, and do not connect the piping commonly with the adjacent system as shown in the right figure. Common piping causes measurement error because the pressure of each system interferes. Passageway Independent piping Room A Room B EMT1 EMT1 Passageway Common piping Room A Room B EMT1 EMT1 b) Prevention of clogged piping due to drain If drain remains within the line, it causes measurement error. Be sure to install the pressure receiving instrument above the pressure outlet port of the pressure detector and arrange the line so that the drain water should not remain in the slack piping. I f the arrangement mentioned above in not possible, install a drain tank within the line as shown in the right figure and clean it once in a while. After the cleaning of the tank, check that the air tightness is fully kept. c) Measurement of high temperature gases In the pressure measurement of high temperature gas, use the pressure detector (pitot tube) made of the heat-proof metal (such as stainless steel), and connect it with the pressure receiving instrument through a metal tube which is long enough to cool down the high temperature gas. Installation diagram of drain tank Drain Drain tank d) Errors caused by long distance piping The speed of response is delayed when the product is used for remote monitoring. In such application, the I.D. of the connection tube should be as large as possible. The time constant is almost inversely proportional to the inner cross sectional area of the piping. If the piping conditions of the high and low pressure side are significantly different, the difference in the piping resistance between high and low puressure side causes the difference in pressure transmission time, and the measurement becomes inaccurate. 5

7 4. Wiring and connection < EMT1A > can be used for cabling or conduit wiring. In addition, try to use wiring accessory or connecting accessories that is separately available. Use shielded wire for input and output wiring on current and voltage signal, and do not put them near power line. Moreover, do not let it go through the same conduit with power line. Use two core shielded wiring for four wires method cable and try to minimize the induction problems coming from AC power supply of the same cable supply. Exercise care about terminal connection number because it is different according to types. Make sure about a code of terminal connecting part on the terminal block, in accordance with the external connection diagram. Use a crimping terminal suitable for M4 terminal screw. (refer to bellow the figure) Provide the the instrument on the grounding terminal with the class D grounding (grounding resistance is 100 Ω or less). Get grounding at the foot of installed unit. Also, EMT1A can get it from the grounding terminal inside the upper cover. Make a one point grounding at the one end of shielded output signal cable. φ9 φ8.2 φ Zero adjusting 1) Since zero point of the instrument is changed according to mounting posture, therefore, after installation of horizontal posture is completed, be sure to perform zero adjustment. 2) After making sure that there is no mistake about wiring and connection, supply each equipment with power and start a warm-up for 10 minutes. 3) Remove tubing of the instrument from High pressure side as well as Low pressure side and vent the atmosphere. 4) Take out the upper cover of the instrument, turn the zero set adjuster inside and set zero point output of the instrument at the value indicated on the table below. 5) As for span set adjusting, it has been adjusted already at our factory. Do not handle it. < EMT1A > Do not handle it. Zero set E < EMT1B > Printed bord Do not handle it. Zero set Out put signal table Output signal (DC) For single pressure range Zero point For zero point center range Zero point 4 to 20mA 4.0mA 12.0mA 0 to 1mA 0.0mA 0.5mA 0 to 5V 0.0V 2.5V 1 to 5V 1.0V 3.0V 6

8 6. Connectors and piping a) VT connector for vinyl or plastic tube, resin-made [ installed ] These are connectors for vinyl, plastic or rubber tubes. Be sure to use I.D. 6 and thickness of 1 mm or more. However, the vinyl or plastic tube (2 or more wall thickness) with enough withstanding pressure (including vacuum pressure) is required when the instrument range or the line pressure is higher more than 50 kpa. VT type connector Product code KGAT1VT MT type connector Product code KGAT1MT b) MT connector for metal tube, brass-made [ option ] This connector can be connected to the metal tube made from copper, aluminum and so on. (O.D. 6, the tolerance ± 0.1, ring joint type) In case of connecting with stainless tube, use MTW connector. When this connector is connected to hard plastic tube (O.D. 6, I.D. 4), remove the brass-made sleeve and use the resinous inner sleeve set (XIN6 4) that is the optional accessory. (Fig. Ⅴ -1) Inner sleeve set for plastic tube Product code XIN6X4 inner (resin) sleeve (resin) plastic tube (Fig. Ⅴ -1) c) Inner sleeve set [ option ] You need this to connect hard plastic tube (O.D. 6, I.D. 4) to the connectors for metal tube. (Fig. V-1) MTW type connector g) MTW connector (double ring joint type) stainless steel made [ option ] This is connector can be connected to stainless tube (O.D. 6, the tolerance ± 0.1). Product code KGAT1MTW-S 7

9 Ⅵ. ACCESSORY FOR MANOSYS PRESSURE TRANSMITTER (OPTION) 1. Installation bracket on vertical wall For installation bracket on vertical wall. Install this instrument at horizontal position (inclination angle at 5 ). If installation surface is vertical, use the installation bracket on vertical wall to install horizontally. Take the space of 0.5 m above the transmitter for the purpose of adjustment and maintenance φ5 installation holes for Manosys Transmitter Product code BRKT-EMT installation holes on wall 2. Accessory for wiring and connection There are two indoors wire connection methods and each will require dedicated accessory. a) For wiring Plastic ground is used to wiring transmitter with instrumentation cable. Choose the plastic ground of the size that rubber bush hold external of cable as shown right table. Be carefully O.D. of cable Plastic ground G 1/2 φ14 Product code φd Rubber bushing color Rubber bushing Applicable cable outer diameter (mm) Min. Max. XAC4-2 Black XAC4-3 Red XAC4-4 Green φ14.6 b) For wiring conduit When you wire the conduit tube of normal diameter 19 or pliable metal conduit throughout the conduit tube, use the adaptor for conduit as shown right figure. Because wire inlet size of the transmitter differ by internal thread of G 1 / 2. Adaptor for conduit G 1/2 φ15 C19 Thread for cable conduit 22 Product code ADPA-EMT1 8

10 Ⅶ. LINE PART ACCESSORY Pulsating protector In case of strong turbulent flow of medium air that causes abnormal movement of pointer and output of transmitter, installing a pulsation protector applicable pressure range one each on H side and L side on the piping way between pressure sensor and the instrument. Outline drawing for pulsating protector For vinyl or plastic tube 75 For metal tube Hex.12 Hex.12 Product code Applicable range (max. value) For vinyl or plastic tube For metal tube Pa, kpa RS-VT6-02 RS-MT Pa or less RS-VT6-03 RS-MT , 500, 1000 Pa RS-VT6-04 RS-MT6-04 2, 3, 5, 10 kpa RS-VT6-06 RS-MT kpa or more φ6± φ6±0.1 Corrosive gas absorber In case of measurement of gas which corrodes the material of the instrument, installing that corrosive gas absorber one each on H side and L side each on piping way between pressure detector prolong instrument life. Outline drawing for corrosive gas absorber For vinyl or plastic tube φ27 Granular activated carbon For metal tube Hex.12 Hex For vinyl or plastic tube Product code FG-VT6-S For metal tube Product code FG-MT6-S φ6± φ27 φ6±0.1 Air filter for instrument For measurement of dusty air, install air filter for instrument one each on H side and L side in the middle of piping between the pressure detector and the instrument. According to the condition of clogging inside filter, carry out periodically replacement of filter element as well as cleaning of the pressure detector and piping. Outline drawing for instrument air filter For vinyl or plastic tube Hex For vinyl or plastic tube For metal tube For metal tube Hex.17 Hex.12 Product code AF-VT6 Product code AF-MT6 φ6± φ6±0.1 9

11 Ⅷ. PERIODIC INSPECTION Generally speaking, it is important not to exert external stress to keep life and reliability of the instrument for a long time. Proper use of this instrument will ensure its faultless service over many years without any necessity of periodic lubrication. However, it is recommended that it is subjected to periodic inspection (calibration) once a year. Ⅸ. PRODUCT WARRANTY Warranty Period This product warranty is valid for one year from the date of delivery to a place specified by an ordering party who has transacted directly with Yamamoto Electric Works Co., Ltd. Coverage If a product breaks down due to a reason for which we are responsible during the warranty period and you return the product to us, we will either repair or replace the product free of charge. This warranty does not cover (1) Usage of the product under any inappropriate conditions or environment contrary to what is described in our product catalog, specifications or manual. Handling or usage of the product other than as described in our product catalog, specifications or manual. (2) Breakdown due to a reason other than a fault within our product. (3) Any product that has been modified or repaired by a party other than us. (4) Any breakdown due to a reason that was not foreseeable based on scientific and technical standards applied at the time of shipment. (5) Any breakdown due to a reason not attributable to us such as a natural calamity or other disaster. These terms of warranty represent our entire liability with respect to the product, and we shall have no liability for any other loss arising in connection with a breakdown of the product. *This product warranty is only valid within Japan. This document is a translation from the original Japanese version, and the original Japanese version has priority over this translation. Be sure to refer to the original Japanese for the details of this warranty. 10

12 Caution (critical damages to the product can be caused if not avoided.) Inrush of over-loading The diaphragm and the retainer are broken if the pressure exceeding the withstanding pressure of the receiving element is applied to the instrument. The case body and the transparent cover of the instrument are broken if the pressure exceeding the withstanding pressure of the instrument body is applied to the instrument. Dropping the product If a Manostar product is dropped onto a desk or floor, not only its exterior but also interior mechanism is broken. Cleaning with organic solvent Use a cloth soaked with water-diluted neutral detergent to wipe the surface of a product. Using of organic solvent causes damage on the surface.. Wrong terminal connection If the signal input and output terminals are connected to the power supply, the internal mechanism burns out. The withstanding pressure of the pressure receiving element means ; The max. pressure under which the diaphragm withstands distortion or breakage (withstand single pressure) The single pressure acting on either H or L side. The withstanding pressure of the instrument body means ; The max. pressure under which the instrument body withstand safely without breakage (double side withstanding pressure) The pressure acing on both high and low sides. Note The withstanding pressure of the instrument body is not the pressure under which the airtigh t ness of the instrument is guaranteed. Caution I f the pressure exceeding the withstanding pressure of the pressure receiving element is applied to both L and H sides at the same time, the imbalance of the ultimate pressure arising from the difference in the capacity between the L side and H side chambers or tube. It may cause the pressure exceeding the withstanding pressure and the breakage or distortion of the diaphragm. When applying the pressure exceeding the withstanding pressure of the diaphragm from both H and L sides at the same time, increase the pressure slowly and gradually. Likewise, in relieving the pressure, decrease the pressure slowly. <Prior notice> The specifications and description of the product explained in this instruction manual may be subject to change without prior notice because of modification and the like. 11

INSTRUCTION MANUAL MANOSTAR TRANSMITTER EMT1. RoHS READ THE INSTRUCTION MANUAL BEFORE USING. No. TR-EMT1-E08

INSTRUCTION MANUAL MANOSTAR TRANSMITTER EMT1. RoHS READ THE INSTRUCTION MANUAL BEFORE USING. No. TR-EMT1-E08 RoHS READ THE INSTRUCTION MANUAL BEFORE USING INSTRUCTION MANUAL MANOSTAR TRANSMITTER No. TR--E08 1-2-,Nishi-shiriike-cho,Nagata-ku,Kobe,Hyogo 65-001 JAPAN TEL. +81(78)-61-6000 FAX. +81(78)-61-6020 INTRODUCTION

More information

Low Differential Pressure Gage

Low Differential Pressure Gage Low Differential Pressure Gage Manostar Gage General purpose compact type Low Differential Pressure Gage RoHS compliant Flag pointer is installed normally, which are easily to manage predicted value or

More information

RoHS Compliant READ THE INSTRUCTION MANUAL INSTRUCTION MANUAL ,Nishi-shiriike-cho,Nagata-ku,Kobe,Japan TEL: FAX:

RoHS Compliant READ THE INSTRUCTION MANUAL INSTRUCTION MANUAL ,Nishi-shiriike-cho,Nagata-ku,Kobe,Japan TEL: FAX: RoHS Compliant READ THE INSTRUCTION MANUAL INSTRUCTION MANUAL MANOSTAR SWITCH MS30 TR-MS30-E06 653-0031 1-2- 3,Nishi-shiriike-cho,Nagata-ku,Kobe,Japan TEL078-631-6000 FAX078-631-6020 TABLE OF CONTENTS

More information

Low Differential Pressure Gage

Low Differential Pressure Gage Low Differential Pressure Gage Manostar Gage General purpose type Low Differential Pressure Gage RoHS compliant Broad line-up of product Supporting the air volume scale and the air velocity scale (refer

More information

RoHS Compliant READ THE INSTRUCTION MANUAL INSTRUCTION MANUAL ,Nishi-shiriike-cho,Nagata-ku,Kobe,Japan TEL: FAX:

RoHS Compliant READ THE INSTRUCTION MANUAL INSTRUCTION MANUAL ,Nishi-shiriike-cho,Nagata-ku,Kobe,Japan TEL: FAX: RoHS Compliant READ THE INSTRUCTION MANUAL INSTRUCTION MANUAL MANOSTAR SWITCH MS65 MS65F(WITH AIR FILTER) TR-MS65-E09 653-0031 1-2- 3,Nishi-shiriike-cho,Nagata-ku,Kobe,Japan TEL078-631-6000 FAX078-631-6020

More information

RoHS Compliant READ THE INSTRUCTION MANUAL INSTRUCTION MANUAL ,Nishi-shiriike-cho,Nagata-ku,Kobe,Japan TEL: FAX:

RoHS Compliant READ THE INSTRUCTION MANUAL INSTRUCTION MANUAL ,Nishi-shiriike-cho,Nagata-ku,Kobe,Japan TEL: FAX: RoHS Compliant READ THE INSTRUCTION MANUAL INSTRUCTION MANUAL MANOSYS DIGITAL LOW DIFFERENTIAL PRESSURE GAGE EMD7D3 TR-EMD7D3-E09 653-0031 1-2- 3,Nishi-shiriike-cho,Nagata-ku,Kobe,Japan TEL078-631-6000

More information

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions Series ISE70/75/75H NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. For General Fluids For Air 2-Color Display (Green/Red) Selectable from four patterns ON Red Green Red Green

More information

MEMS Gauge Pressure Sensor

MEMS Gauge Pressure Sensor MEMS Gauge Pressure Sensor MEMS Gauge Pressure Senser Featuring Small Size and Low Power Consumption Ultra-miniature 6.1 4.7 8.2 mm (L W H). Superior electrical characteristics to capative type pressure

More information

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type Series ISE70/75/75H New NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. For General Fluids For Air 2-Color Display (Green/Red) Selectable from four patterns ON Red Green Red

More information

Differential Pressure Transmitter

Differential Pressure Transmitter Specifications/Instructions Differential Pressure Transmitter General Model PY9000D is a differential pressure transmitter that uses a ceramic cantilever sensor. Deflection of the ceramic cantilever caused

More information

Ordering Information. MEMS Gauge Pressure Sensor 2SMPP. MEMS Gauge Pressure Sensor Featuring Small Size and Low Power Consumption

Ordering Information. MEMS Gauge Pressure Sensor 2SMPP. MEMS Gauge Pressure Sensor Featuring Small Size and Low Power Consumption MEMS Gauge Pressure Sensor 2SMPP MEMS Gauge Pressure Sensor Featuring Small Size and Low Power Consumption Ultra-miniature 6.1 4.7 8.2 mm (L W H). Piezo Resistive element provides electrical characteristics

More information

Ordering Information. MEMS Gauge Pressure Sensor 2SMPP. MEMS Gauge Pressure Sensor Featuring Small Size and Low Power Consumption

Ordering Information. MEMS Gauge Pressure Sensor 2SMPP. MEMS Gauge Pressure Sensor Featuring Small Size and Low Power Consumption MEMS Gauge Pressure Sensor 2SMPP MEMS Gauge Pressure Sensor Featuring Small Size and Low Power Consumption Ultra-miniature 6.1 4.7 8.2 mm (L W H). Piezo Resistive element provides electrical characteristics

More information

Pressure Transmitter

Pressure Transmitter Specifications/Instructions Pressure Transmitter General Model PY7100A pressure transmitter is a small pressure transmitter using a semiconductor strain gauge. It detects the pressure of chilled/hot water,

More information

* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue.

* E8MS-N1 is only 1-channel pressure sensor controller. E80-C2 can be used. For more details, please refer to E80 catalogue. Authorised Distributors:- ASH & ALAIN INDIA PVT LTD S-, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-(India) Tel : -7977 Fax : -7977 E-mail : sales@ashalain.com Sensor Four-Input-Channel Sensor

More information

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES MODE 729 Micro-differential Pressure High-precision Digital Pressure Sensor For Gas SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.1563~ guide... P.699~ General precautions...

More information

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant -Colour Display Digital Pressure Switch Stainless diaphragm Oil-free (Single-layer diaphragm structure) Sensor parts: Stainless steel 6 Fitting parts: Stainless steel 4 The sensor and fitting parts can

More information

2-Color Display High-Precision Digital Pressure Switch

2-Color Display High-Precision Digital Pressure Switch 2-Color Display High-Precision Digital Pressure Switch Series ZSE3/ISE3 2-color digital display allows you to choose the setting according to your application requirements. 4 different display settings

More information

2-Color Display High-Precision Digital Pressure Switch

2-Color Display High-Precision Digital Pressure Switch 2-Color Display High-Precision Digital Pressure Switch Settings can be copied to up to 1 slave sensors at once. The settings of the master sensor can be copied to the slave sensors. Reduced setting efforts

More information

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A 2-Color Display High-Precision Digital Pressure Switch Series ZSEA(F)/ISEA New M8 connector type RoHS IP65 Applicable fluid Air, Non-corrosive gas, Non-flammable gas Can copy to up to 10 switches simultaneously.

More information

Lumitester PD-20 Control Kit

Lumitester PD-20 Control Kit 日本語による取扱説明は 17 ページからとなります Lumitester PD-20 Control Kit Operation manual Thank you for purchasing the Lumitester PD-20 Control Kit. To use this kit safely and correctly, read this operation manual carefully

More information

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE High Precision, 2-color Display Digital Pressure Switch Series SE30/ISE30 SE ISE PSE I SE3 PS I SE 1 2 SP ISA2 IS SM PF2 IF Data With One-touch fittings are newly introduced. Straight type Elbow type 16-2-1

More information

Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES

Head-separated Digital Pressure Sensor DP5 SERIES DPH SERIES 76 ORDER GUIDE DP / configuration diagram Intermediate cable s Type Vacuum pressure Positive pressure Compound pressure Appearance An intermediate cable is required to connect the controller and the sensor

More information

2-Color Display Digital Pressure Switch

2-Color Display Digital Pressure Switch -Color Display Digital Pressure Switch Series ZSE80(F)/ISE80(H) Stainless diaphragm Oil-free (Single-layer diaphragm structure) Sensor parts: Stainless steel 630 Fitting parts: Stainless steel 304 The

More information

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES MODE 751 Micro-differential Pressure High-precision Digital Pressure Sensor For Gas SERIES Related Information General terms and conditions... F-7 Glossary of terms... P.1469 ~ Sensor selection guide...

More information

HL (AZH) LIMIT SWITCHES

HL (AZH) LIMIT SWITCHES COMPACT SIZE LIMIT SWITCHES LIMIT SWITCHES U L PRODUCT TYPE 1. Limit Switches Actuator Type Push plunger Roller plunger Cross roller plunger Panel mount push plunger Panel mount roller plunger Panel mount

More information

VSG Series Features Descriptions VSG VSG VSG Descriptions Supply valve Descriptions Vacuum filter

VSG Series Features Descriptions VSG VSG VSG Descriptions Supply valve Descriptions Vacuum filter Basic performance oriented general vacuum ejector unit Series Nozzle diameter: ø.5, ø, ø1. acuum switch and vacuum break valve, etc. are unitized, so types matching the work purpose is selectable. Features

More information

No.EX -OME0016-A PRODUCT NAME. SI unit. MODEL / Series / Product Number EX140-SDN1

No.EX -OME0016-A PRODUCT NAME. SI unit. MODEL / Series / Product Number EX140-SDN1 No.EX -OME0016-A PRODUCT NAME SI unit MODEL / Series / Product Number EX140-SDN1 Table of Contents 1. Safety instructions 2 2. Specifications 7 2-1. General specifications 7 2-2. Electrical ant network

More information

Digital display Pressure range ON/OFF output Linear output Model

Digital display Pressure range ON/OFF output Linear output Model Slim Digital Pressure Sensor E8CC with Built-in Microcomputer and Digital Display Withstands a pressure of 49 kpa and highly reliable. Incorporates a two-turn pressure adjuster ensuring easy pressure setting.

More information

Related vacuum products

Related vacuum products Vacuum component C O N T E N T S variation 420 Position locking valve () 422 Compact vacuum regulator () 426 Vacuum break unit () 436 Vacuum filter large volume union type (VSFB) 440 Compact vacuum filter

More information

Differential Pressure Sensors

Differential Pressure Sensors 1 920 1920P01 Differential Pressure Sensors for neutral and mildly corrosive liquids and gases QBE63-DP Differential pressure sensor, suitable for gases and liquids, for the measurement of positive and

More information

THT-500-A/R INSTRUCTION MANUAL TEMPERATURE AND HUMIDITY TRANSMITTER

THT-500-A/R INSTRUCTION MANUAL TEMPERATURE AND HUMIDITY TRANSMITTER INSTRUCTION MANUAL TEMPERATURE AND HUMIDITY TRANSMITTER THT-500-A/R No.THT51E1 2017.12 Thank you for purchasing our THT-500-A/R, Temperature and Humidity Transmitter (mounted within control panel). This

More information

VERTICAL TYPE LIMIT SWITCHES (INCLUDES LAMP TYPE)

VERTICAL TYPE LIMIT SWITCHES (INCLUDES LAMP TYPE) VERTICAL TYPE LIMIT SWITCHES (INCLUDES LAMP TYPE) Limit Switches General use vertical limit switch. Type with a lamp which makes maintenance convenient; either a neon AC powered lamp or an LED DC powered

More information

CAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE*

CAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE* CAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE* Specifications - Installation and Operating Instructions Bulletin B-34 Series 43000 CAPSU-Photohelic Switch/Gage The CAPSU-Photohelic Switch/Gage is a most versatile,

More information

10 PSE53 0 M5. Port size. M5 x 0.8 ø6 reducer 1/4-inch reducer. the cable at the time of shipment. 10-PSE to -101 kpa

10 PSE53 0 M5. Port size. M5 x 0.8 ø6 reducer 1/4-inch reducer. the cable at the time of shipment. 10-PSE to -101 kpa Series 0-PSE50 Remote type pressure sensor How to Order Clean series 0 PSE5 0 M5 Pressure sensing range Option 0 2 High pressure [0 to MPa] Vacuum [0 to 0 kpa] Low pressure [0 to 0 kpa] Compound pressure

More information

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type. MPa MPa (ISE75H) 2-color digital. Functions -Color Display Digital Pressure Switch /75/75H Series NPN/PNP open collector outputs added. Zero-cut off display function added. For General Fluids For Air Rated Pressure Metal Body Type 0 5 (E75) () -Color

More information

Digital display Pressure range ON/OFF output Linear output Model

Digital display Pressure range ON/OFF output Linear output Model Slim Digital Pressure Sensor E8CB/ CSM_E8CB DS_E 1 with Built-in Microcomputer and Digital Display Withstands a of 9 kpa and highly reliable. Incorporates a two-turn adjuster ensuring easy setting. Be

More information

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor 2-Color Display High-Precision Digital Pressure Switch ZSE ISE RoHS ZSE ISE IP65 ZSE40 ISE40 M8 connector type ZSE10 ISE10 ISE70 ZSE80 ISE80 PS ISA3 ISA2 ISE35 Applicable Air, Non-corrosive gas, Non-flammable

More information

Analog Resistive Touchscreen QST Series Product Specifications

Analog Resistive Touchscreen QST Series Product Specifications Analog Resistive Touchscreen QST Series Product Specifications Table of Contents 1. Product Specifications...3 1-1. Product Applicable...3 1-2. Structure...3 1-3. Environmental Specifications...3 1-4.

More information

Instruction Manual. Digital Panel Meter Model 3126 CAUTION. Code Type of T/C Measuring Range Display Range Accuracy

Instruction Manual. Digital Panel Meter Model 3126 CAUTION. Code Type of T/C Measuring Range Display Range Accuracy Instruction Manual Digital Panel Meter Model 3126 I-01861 1. Preface Thank you for purchasing our digital panel meter 3126 series. Before use, read this manual carefully and thoroughly, and keep this manual

More information

Differential Pressure Sensors

Differential Pressure Sensors 1 920 1920P01 Differential Pressure Sensors for neutral and mildly corrosive liquids and gases QBE63-DP Differential pressure sensor, suitable for gases and liquids, for the measurement of positive and

More information

Pressure Transmitters

Pressure Transmitters S E L E C T I O N G U I D E Pressure Transmitters Pressure Transducers ASAHI GAUGE MFG. CO.,LTD. JAPAN Small-size pressure-resistant & explosion-proof pressure Pressure-resistant & explosion-proof differential

More information

Pressure Sensor/PS-A (ADP5)

Pressure Sensor/PS-A (ADP5) Sensor PS-A sensor Built-in amplifi er and compensating circuit Features Built-in amplifier and temperature compensation circuit, no need for circuit design and characteristic adjustment High accuracy

More information

Read and understand this manual for safely usage.

Read and understand this manual for safely usage. TS02-0180 INSTRUCTION MANUAL FOR AIR BUBBLER SYSTEM LEVEL MEASUREMENT MODEL:LA100 MODEL:LA110 MODEL:LA1000 Read and understand this manual for safely usage. This manual describes the product of standard

More information

Differential Pressure Sensor

Differential Pressure Sensor Differential Pressure Sensor "Cube" Type Differential Pressure Sensor with LED Display Offers High Precision Sensing 31 (1.) x 3 (1.18) x 3 (1.18) mm compact-cube style saves mounting space Easy-to-read

More information

DL (AZD1) Mini Limit Switches

DL (AZD1) Mini Limit Switches COMPACT SIZE LIMIT SWITCES DL (1) Mini Limit Switches (with forced contact opening mechanism) An economic compact limit switch equipped with a forced contact opening mechanism and excellent environment

More information

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, IN 46361, U.S.A. Fax: 219/

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, IN 46361, U.S.A. Fax: 219/ Series 43000 Capsu-Photohelic Pressure Switch/Gage Specifications - Installation and Operating Instructions Bulletin B-34 Ø4-3/4 [120.65] 3-7/8 SQ [98.43] 3/4 CONDUIT 4-3/8 [111.13] HOUSING REMOVAL 3-1/16

More information

SPV Series Slides OPERATING MANUAL. Table of contents 1 Introduction Compliance with the EC Directives Names of parts...

SPV Series Slides OPERATING MANUAL. Table of contents 1 Introduction Compliance with the EC Directives Names of parts... HL-17012 SPV Series Slides OPERATING MANUAL Thank you for purchasing an Oriental Motor product. This Operating Manual describes product handling procedures. Please read this Operating Manual and the separate

More information

Construction diagram Semiconductor transducer Silicone oil. Stainless steel SUS316 pressure port Hastelloy C diaphragm.

Construction diagram Semiconductor transducer Silicone oil. Stainless steel SUS316 pressure port Hastelloy C diaphragm. SERIES LED Display Anti-corrosive Digital ure Sensor DP3 ure Measurement of Corrosive Gases and Liquids Possible! Marked Conforming to EMC Directive Superior Anti-corrosive Hastelloy C Diaphragm and Stainless

More information

Differential Pressure Sensors

Differential Pressure Sensors 1 910 1910P01 Differential Pressure Sensors for air or nonaggressive gases QBM66... Pressure-linear characteristic with selectable pressure measuring range Operating voltage AC 24 V or DC 13.5...33 V Output

More information

SL (AZ3) Micro Limit Switches

SL (AZ3) Micro Limit Switches SUBMINIATURE SIZE LIMIT SWITCHES SL (AZ3) Micro Limit Switches Quickly upgraded to limit switches with lamps by mounting an LED lamp socket. Rubber cover type (roller ) Compliance with RoHS Directive FEATURES

More information

ISE6B. Series ZSE6B. Digital Pressure Switch. With Backlight. (For vacuum) (For positive pressure) For General Purpose Fluids

ISE6B. Series ZSE6B. Digital Pressure Switch. With Backlight. (For vacuum) (For positive pressure) For General Purpose Fluids Leakage rating: 1 X 10-9 atm cc/s With Backlight Digital Pressure Switch Series ZSE6B (For vacuum) ISE6B (For positive pressure) Sensor and fitting section are electron beam welded. 2 kinds of metal gasket

More information

Low Differential Pressure Sensor ±1% F.S.

Low Differential Pressure Sensor ±1% F.S. CAT.ES100-49 A Low Differential Pressure Sensor Rated differential pressure range: 0 to 2 kpa Accuracy: ±1% F.S. LED display to confirm energization Series PSE550 Proof pressure: 65kPa Output: 1 to 5VDC

More information

PG-30 PRESSURE GAUGES P G R - N MODEL NUMBER DESIGNATION

PG-30 PRESSURE GAUGES P G R - N MODEL NUMBER DESIGNATION INTERNAL STRUCTURE 5 1 marking Compatible with EMC directive 2 6 4 3 Part name Material 1 Pressure sensor P-2000 2 Sensor O ring NBR 3 Adaptor Aluminum Die-casting 4 Case O ring NBR 5 Case PBT (Polybutyleneterephthalate)

More information

HL (AZH) Limit Switches

HL (AZH) Limit Switches COMPACT SIZE LIMIT SWITCHES HL (AZH) Limit Switches Wide selections of actuators, terminals and bodies to meet any application Excellent environmental resistance Die casting caseiec IP67 Plastic caseiec

More information

PG-30 PRESSURE GAUGES P G R - N FEATURES MODEL NUMBER DESIGNATION

PG-30 PRESSURE GAUGES P G R - N FEATURES MODEL NUMBER DESIGNATION marking Compatible with EMC directive INTERNAL STRUCTURE 5 1 2 6 4 3 Part name Material FEATURES 1 Pressure sensor P-2000 Compact and lightweight general-purpose pressure gauges Innovative general-purpose

More information

2-Color Display Digital Pressure Switch

2-Color Display Digital Pressure Switch -Color Display Digital Pressure Switch Series ZSE80(F)/ISE80(H) Stainless diaphragm Oil-free (Single-layer diaphragm structure) Sensor parts: Stainless steel 630 Fitting parts: Stainless steel 304 The

More information

The T5220 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

The T5220 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output. GENERAL INFORMATION T5220 SERIES TRANSDUCER Electro-Pneumatic (I/P, E/P) APPLICATIONS The T5220 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional

More information

2-Color Display Digital Pressure Switch

2-Color Display Digital Pressure Switch -Color Display Digital Pressure Switch (F)/(H) Series Stainless diaphragm Oil-free (Single-layer diaphragm structure) Sensor unit: Stainless steel 630 Fitting parts: Stainless steel 304 The sensor unit

More information

ELECTRONIC CONTROL ACTUATOR

ELECTRONIC CONTROL ACTUATOR ELECTRONIC CONTROL ACTUATOR Nucom Series LINEAR TYPE Nucom L25 Nucom L50 OPERATION MANUAL Koei Industry Co., Ltd. FOR YOUR SAFETY In order for better and safety use of the product for a long period, please

More information

OPERATING INSTRUCTION

OPERATING INSTRUCTION 11/05 Form #273 OPERATING INSTRUCTION MODEL 4105 Disital Earth Resistance Tester 2150 joshua's Path, Suite 302, Hauppauge, NY 11788 Phone : 1-800-645-5398 or 1-639-231-7050 Fax : 1-639-434-3128 E-mail

More information

Set value (Threshold value) Bottom value. *2 Further reduced by approx. 60% in power-saving mode (For 20 series)

Set value (Threshold value) Bottom value. *2 Further reduced by approx. 60% in power-saving mode (For 20 series) 3-Screen Display High-Precision Digital Pressure Switch New Added Variations! For general fluids IP65 2 outputs Analog output Setting is possible while checking Main screen the measured value. Sub screen

More information

Series 10-ZSE40A(F)/10-ISE40A

Series 10-ZSE40A(F)/10-ISE40A Series 10-ZSEA(F)/10-ISEA RoHS 2-Color Display High Precision Digital Pressure Switch How to Order For positive pressure Clean series For vacuum/ compound pressure 01 N01 W1 10 Rated pressure range ISEA

More information

Vacuum pump system type

Vacuum pump system type type VS*P Vacuum component C O N T E N T S Series variation 166 20 mm width universal type (/M) 168 10.5 mm width universal type (/M) 184 31.5 mm width discrete type (VSQP) 214 11 mm pitch manifold dedicated

More information

DIGITAL RCD(ELCB) TESTER

DIGITAL RCD(ELCB) TESTER INSTRUCTION MANUAL DIGITAL RCD(ELCB) TESTER KEW 5410 R KYORITSU ELECTRICAL INSTRUMENTS WORKS, LTD. Contents 1. Safety Warnings.... 1 2. Procedure of removing Cover. 3 2-1 Method of removing the Cover.

More information

Super fast 1 ms Convenient intermediate cable with connector A total of 10 head variations

Super fast 1 ms Convenient intermediate cable with connector A total of 10 head variations SERIES Digital Sensor Digital Automatic sensitivity setting Auto reference With analog output /, sec. The fastest response in the industry DP DP Conforming to EMC Directive UL Recognition Super fast ms

More information

EDR-N8A CS Intelligent Absolute Pressure Transmitter STANDARD SPECIFICATIONS. Accuracy Material Code: Standard,316L Range Accuracy Code

EDR-N8A CS Intelligent Absolute Pressure Transmitter STANDARD SPECIFICATIONS. Accuracy Material Code: Standard,316L Range Accuracy Code Intelligent Absolute Pressure Transmitter Absolute Pressure Transmitter incorporates semiconductor sensors and a microcomputer and converts measured s to 4 to 20mA DC signal with high accuracy. is suitable

More information

Pressure Drop (Reference (typical)) 0.19 kpa 0.48 kpa Operating Temperature

Pressure Drop (Reference (typical)) 0.19 kpa 0.48 kpa Operating Temperature MEMS Mass Flow Sensor D6F-P A Compact, High-performance Flow Sensor with Dust Segregation Structure. Built in Dust Segregation System (DSS) with cyclone flow structure, diverts particulates from sensor

More information

Differential Pressure Sensors

Differential Pressure Sensors 1 910 1910P01 Differential Pressure Sensors for air or nonaggressive gases QBM66... Pressure-linear characteristic with selectable pressure measuring range Operating voltage AC 24 V or DC 13.5...33 V Output

More information

HL (AZH) Limit Switches

HL (AZH) Limit Switches COMPACT SIZE LIMIT SWITCHES HL (AZH) Limit Switches Compact, high-performance limit switch with superior environmental resistance. Broad lineup covers from die casting cases to economical plastic cases.

More information

9.8 mm. Digital Pressure Switch. 3-step setting. RoHScompliant. Series ZSE10(F)/ISE10. Vertical mounting space reduced to approx.! Reduced in depth!

9.8 mm. Digital Pressure Switch. 3-step setting. RoHScompliant. Series ZSE10(F)/ISE10. Vertical mounting space reduced to approx.! Reduced in depth! Digital Pressure Switch Series ZSE1(F)/ISE1 Low profile 26.1mm 9.8 mm 13.5 mm 53.4 mm Reduced in depth! (Actual size) RoHScompliant Vertical mounting space reduced to approx.! 1 2 Position Detection Switch

More information

A6 type. General universal type. Submerged type Connector box type. Installation method Titanium PPS FKM

A6 type. General universal type. Submerged type Connector box type. Installation method Titanium PPS FKM Industrial Conductivity (Electric Conductivity) Detector A5/A6 type (For general multipurpose) AR4/AR5 type (for small purified water equipment) Dual electrode conductivity (electrical conductivity) detector

More information

OPERATING INSTRUCTION

OPERATING INSTRUCTION 11/05 Form #271 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 OPERATING INSTRUCTION Visit us at www.testequipmentdepot.com MODEL 3132 ANALOG INSULATION-CONTINUITY TESTER

More information

DPS280 / DVS280 Series

DPS280 / DVS280 Series 1 2 3 4 5 6 7 8 Do not use corrosive or flammable gases or liquid with this product. Please use within the rated pressure range. Do not apply pressure beyond recommended maximum pressure, permanent damage

More information

EX Series. Electric Actuators for Ball and Butterfly Valves

EX Series. Electric Actuators for Ball and Butterfly Valves EX Series Electric Actuators for Ball and Butterfly Valves Next-Generation Electric Actuator Realization of Upgraded General-Purpose Actuators The modularization and adoption of the common parts have brought

More information

INSTRUCTION MANUAL BIPOLAR POWER SUPPLY PBA SERIES OPTIONAL RACK-MOUNTING ATTACHMENT OM-21E PRINTED IN JAPAN B

INSTRUCTION MANUAL BIPOLAR POWER SUPPLY PBA SERIES OPTIONAL RACK-MOUNTING ATTACHMENT OM-21E PRINTED IN JAPAN B INSTRUCTION MANUAL BIPOLAR POWER SUPPLY PBA SERIES PBA20-12 PBA20-24 OPTIONAL RACK-MOUNTING ATTACHMENT OM-21E PRINTED IN JAPAN B68-0175-00 About Brands and Trademarks Our company and product names described

More information

PFA Eddysonic flowmeter

PFA Eddysonic flowmeter PFA Eddysonic flowmeter CE marking Approval Conforms to the CE marking The Eddysonic Flowmeter is a flowmeter for fluids that detects the vortex street using the ultrasonic sensor mounted on the outside

More information

Simple Pressure Level Setting. The threshold level is able to adjust simply. Just set the pointer suitable for the displayed pressure level.

Simple Pressure Level Setting. The threshold level is able to adjust simply. Just set the pointer suitable for the displayed pressure level. SERIES LED Bar Display Mechanical Switch is Out of Date Choose the Contemporary Pressure Sensor with LED Bar Display Marked Conforming to EMC directive Bright LED Bar Display Easy to read the pressure

More information

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range. 2-Color Display High-Precision Digital Pressure Switch Series ZSE3A(F)/ISE3A RoHS Can copy to up to 1 switches simultaneously. The settings of the master sensor can be copied to the slave sensors. Reducing

More information

Three Lobes Roots Blower. Instruction Manual

Three Lobes Roots Blower. Instruction Manual Three Lobes Roots Blower Instruction Manual Welcome to purchase the three lobes roots blower produced by us. You shall read this instruction manual seriously before you use this product in order to ensure

More information

INSTRUCTION MANUAL ANALOGUE INSULATION TESTER KEW 3131M KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD., TOKYO JAPAN

INSTRUCTION MANUAL ANALOGUE INSULATION TESTER KEW 3131M KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD., TOKYO JAPAN INSTRUCTION MANUAL ANALOGUE INSULATION TESTER KEW 3131M KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD., TOKYO JAPAN Contents 1. Safety Precautions... 1 2. Features... 3 3. Specifications... 4 4. Instrument

More information

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa 5.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator X Series This product is only for blowing gas. This product does not have sufficient pressure control for other applications (driving,

More information

Unit specifications. Nil. Option 1. Power supply/output connection cable. Option 2

Unit specifications. Nil. Option 1. Power supply/output connection cable. Option 2 Series -PSE3 RoHS Remote Type 2-Color Display Digital Pressure Sensor Controller How to Order 2 3 4 5 Nil Options/Part No. L Input/Output specifications NPN2 output to 5 V output NPN2 output 4 to 2 m output

More information

Pressure sensor with built-in amplification and temperature compensation circuit

Pressure sensor with built-in amplification and temperature compensation circuit sensor with built-in amplification and temperature compensation circuit PS-A PRESSURE SENSOR (built-in amplification and temperature compensating circuit) NEW FEATURES 1. Contains built-in amplification

More information

RADIAL LEADED INDUCTORS

RADIAL LEADED INDUCTORS RADIAL LEADED INDUCTORS WAVE PARTS NUMBER *Operating Temp. : -25~+105 (Including self-generated heat) L H L 0 8 T B 1 0 1 K =Blank space 1 2 3 4 5 6 7 INDUCTORS /LEADED INDUCTORS 1Series name Code LH 2Characteristics

More information

TECHNICAL GUIDE FOR PROXIMITY SENSORS DEFINITIONS YAMATAKE PROXIMITY SENSOR CATEGORIES

TECHNICAL GUIDE FOR PROXIMITY SENSORS DEFINITIONS YAMATAKE PROXIMITY SENSOR CATEGORIES TECHNICAL GUIDE FOR PROXIMITY SENSORS DEFINITIONS "" includes all sensors that detect the presence of a metallic object approaching the sensing face or near the sensing face without mechanical contact.

More information

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Design Data 3.2 Standard Accessories 3.3 Tolerances

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Design Data 3.2 Standard Accessories 3.3 Tolerances CONTENTS 1 GENERAL 2 STANDARDS 3 TECHNICAL FEATURES 3.1 Basic Design Data 3.2 Standard Accessories 3.3 Tolerances 4 MOTOR DESIGN 4.1 Stator Casing 4.2 Stator Core with Winding 4.3 Stator Winding and Insulation

More information

ELECTRONIC CONTROL ACTUATOR

ELECTRONIC CONTROL ACTUATOR ELECTRONIC CONTROL ACTUATOR Nucom Series LINEAR TYPE Nucom L100 OPERATION MANUAL Koei Industry Co., Ltd. FOR YOUR SAFETY In order for better and safety use of the product for a long period, please observe

More information

Pressure Gauge. Fluid admitted Pressure indication range Accuracy Service temperature range Cap. Resin body GPC (1)

Pressure Gauge. Fluid admitted Pressure indication range Accuracy Service temperature range Cap. Resin body GPC (1) Pressure Gauge Feature The compact-size pressure gauges can be installed in small spaces. With the built-in tube fitting type, tube connection is the only necessary step before pressure indication. Graphical

More information

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models Long-barrel Inductive Proximity Sensor EE CSM_EE_DS_E Proximity Sensor with a Long Screw Length Increased tightening strength. Cable protectors provided as a standard feature. Increased indicator visibility.

More information

PD3/PDV3-20A/25A/40A Series

PD3/PDV3-20A/25A/40A Series Pilot operated 2-port valve for dust collector control (Large port size dust collector valve) PD3/PDV3-20A/25A/40A Series Air operated/with solenoid valve Port size: Rc3/4, Rc1, : Rc1 1 /2-: φ48, Rc1 1

More information

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram Data Sheet 403025 Page 1/10 JUMO dtrans p20 Process pressure transmitter Brief description The JUMO dtrans p20 pressure transmitter with HART interface combines maximum precision with easy operation. It

More information

OPERATION & MAINTENANCE MANUAL FOR SCEN-206 LED & MULTI-FUNCTION TYPE CENTRIFUGE PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION.

OPERATION & MAINTENANCE MANUAL FOR SCEN-206 LED & MULTI-FUNCTION TYPE CENTRIFUGE PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION. OPERATION & MAINTENANCE MANUAL FOR SCEN-206 LED & MULTI-FUNCTION TYPE CENTRIFUGE PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION. M.R.C.LTD. Hagavish 3 st. Israel 58817 Tel: 972 3 5595252, Fax: 972

More information

2-Colour Display Type High-Precision Digital Pressure Switch Series ZSE30/ISE30 How to Order Option 1 Without lead wire Nil Lead wire with connector (Lead wire length: 2m) L For positive pressure For vacuum/low

More information

High-speed detection even a little liquid leak

High-speed detection even a little liquid leak 737 Leak Sensor Related Information Amplifier Built-in EX-F70 SERIES SERIES Sensor selection guide...p.11~ / P.77~ General terms and conditions...p.1 General precautions...p.986~ PHOTO PHOTO Conforming

More information

SERIES LED Display Digital Pressure Sensor. Clearly Visible LED Display with 3 1 /2 Digits

SERIES LED Display Digital Pressure Sensor. Clearly Visible LED Display with 3 1 /2 Digits SERIES LED Display Digital Pressure Sensor Complete Functionality from a Wide Model Line-up Marked Conforming to EMC Directive High Accuracy High Resolution High Speed It achieves a 2.5ms, or less, response

More information

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h) Mechatronic Analog Timer H3AM Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty and

More information

Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display

Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display Installation The VDS-1000 combines either two (2) low voltage, high side or low side, switched outputs

More information

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate 1 919 1919P01 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate Highly accurate measurements with calibration certificate Simple and quick

More information

Model Pressure range ON/OFF output Linear output

Model Pressure range ON/OFF output Linear output Digital Sensor Sensor with Easy-to-Read LED Display status can be checked at a glance from the red digital pressure value and analog bar displays. Measurement pressure is averaged by the chattering prevention

More information

SERIES LED Display Digital Pressure Sensor. Clearly Visible LED Display with 3 1 /2 Digits

SERIES LED Display Digital Pressure Sensor. Clearly Visible LED Display with 3 1 /2 Digits SERIES LED Display Digital Pressure Sensor PE DP-M DP-Y DP3 High Accuracy High Resolution High Speed It achieves a 2.5ms, or less, response time at a high resolution of 1/1,000. It enables highly accurate

More information