G7L. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops. Application Examples. Model Number Legend

Size: px
Start display at page:

Download "G7L. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops. Application Examples. Model Number Legend"

Transcription

1 A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops No contact chattering for momentary drops up to % of rated. Wide-range AC-activated coil that handles 1 to 1 or to VAC at either or Hz. Miniature size for maximum switching power, particularly for inductive loads. Flame-resistance materials (UL9V--qualifying) used for all insulation material. Quick-connect, screw, and PCB terminals, and DIN track mounting available. Conforms to UL, CSA, TUV and meets IEC9. Safety design with contact gap of 3 mm. RoHS Compliant Note. Accessories: E-bracket, Adapter, Front-connecting socket and Cover sold separately. Legend -@@-@@@ of Poles 1: 1 pole : poles. Contact Form Configuration Classification E-bracket mounting (E-bracket is sold separately) Upper bracket mounting PCB mounting With test With test 3. Terminal Shape T: Quick connect terminals (#) B: Screw terminals P: PCB terminals Terminal Quick-connect terminals. Mounting Construction Blank: E-bracket UB : Upper bracket. Special Functions J : With test Screw terminals PCB terminals Contact form SPST-NO -1A-T -1A-B DPST-NO -A-T -A-B SPST-NO -1A-TJ -1A-BJ DPST-NO -A-TJ -A-BJ SPST-NO -1A-TUB -1A-BUB DPST-NO -A-TUB -A-BUB SPST-NO -1A-TUBJ -1A-BUBJ DPST-NO -A-TUBJ -A-BUBJ SPST-NO -1A-P DPST-NO -A-P Application Examples Compressors for air conditioners and heater switching controllers. Switching controllers for power tools or motors. Power controllers for water heaters. Power controllers for dryers. Lamp controls, motor drivers, and power supply switching in copy machines, facsimile machines, and other office equipment. Lighting controllers. Power controllers for packers or food processing equipment. Magnetron control in microwaves. Power controllers for Uninterruptible Power Supply (UPS) List of E-bracket Mounting s Mounting E-brackets DIN Track Mounting Adapter Front-connecting Socket Terminal Quickconnect terminals Screw terminals Contact form SPST-NO -1A-T -1A-TJ With test DPST-NO -A-T -A-TJ With test SPST-NO -1A-B -1A-BJ With test DPST-NO -A-B -A-BJ With test Note. Accessories: E-bracket (R99-), Adapter (PF-D), Front-connecting socket (PF-) and Cover (PF-C) sold separately. 1

2 Ordering Information E-bracket/Adapter/Socket Mounting Quick-connect Terminal 1 pole -1A-T AC: 1,, 1/1, / DC:, 1,, 8, 1 poles -A-T AC: 1,,, 1/1, / DC:, 1,, 8, 1 Upper Bracket Mounting Quick-connect Terminal 1 pole -1A-TUB AC: 1,, 1/1, / DC:, 1,, 8, 1 poles -A-TUB AC: 1,,, 1/1, / DC:, 1,, 8, 1 E-bracket/Adapter Mounting Screw Terminal 1 pole -1A-B AC: 1,, 1/1, / DC:, 1,, 8, 1 poles -A-B AC: 1,, 1/1, / DC: 1,, 8, 1 Upper Bracket Mounting Screw Terminal 1 pole -1A-BUB AC:, 1/1, / DC:, 1,, 8, 1 poles -A-BUB AC: 1,,, 1/1, / DC:, 1,, 8, 1 PCB Mounting 1 pole -1A-P AC: 1/1, / DC: 1,, 8, 1 poles -A-P AC:, 1/1, / DC:, 1,, 8, 1 DIN Track Mounting Accessories Applicable products Name Adaptor Surface Connection Socket DIN Track End plate Spacer PFP-1N PFP-N PFP-1N PFP-M PFP-S pcs./tray pcs./tray pcs./tray pcs./tray pcs./tray 1 pcs. Note. Order the models above in increments of the minimum quantity packaged. E-bracket/Adapter/Socket Mounting (with test ) Quick-connect Terminal 1 pole -1A-TJ poles -A-TJ Upper Bracket Mounting (with test ) Quick-connect Terminal 1 pole -1A-TUBJ AC:, 1/1, / DC:, 1,, 8, 1 poles -A-TUBJ AC: 1,,, 1/1, / DC:, 1,, 8, 1 E-bracket/Adapter Mounting (with test ) Screw Terminal 1 pole -1A-BJ AC: 1,, 1/1, / DC: 1, poles -A-BJ AC:, 1/1, / DC: 1,, 8, 1 Upper Bracket Mounting (with test ) Screw Terminal 1 pole -1A-BUBJ AC:, 1/1, / DC:, 1,, 8 poles -A-BUBJ AC:, 1/1, / DC:, 1,, 8, 1 Note 1. Please add the coil rated (V) to the model number when ordering. Example: -1A-T AC1 In addition, the delivered product and its package will be marked with specification as "@@ VDC". Note. Refer to the precautions on PCB Relays provided in eneral Information of the Relay Product Data Book, and "w -@-3" for coil characteristics of AC operation. E-bracket/Adaptor/Socket/Cover Applicable Relay models -1A-T -1A-TJ -1A-B -1A-BJ -A-T -A-TJ -A-B -A-BJ -1A-T -1A-TJ -A-T -A-TJ -1A-B -1A-BJ -1A-BUB -1A-BUBJ -A-B -A-BJ -A-BUB -A-BUBJ AC:, 1/1, / DC: 1,, 8, 1 AC:, 1/1, / DC:, 1,, 8, 1 Name pcs./tray pcs./tray pcs./tray pcs./tray E-bracket R99-1 pcs. Adapter PF-D 1 pcs. Front-connecting Socket PF- 1 pcs. Cover PF-C 1 pcs. Note. Order the models above in increments of the minimum quantity packaged.

3 Ratings Coil Item Max. Coil inductance (H) Must operate Must release permissible Rated current Coil resistance (ma) (Ω) Armature Armature Rated ON OFF On the basis of rated 1 VAC 1 VAC 1 % max. 1% min. % VAC 3 1 to 1 VAC 1. to. V max. 18 V min. 13 V to VAC 8. to 1. 1 V max. 3 V min. V Power consumption (VA-W) Approx. 1. to. VDC VDC VDC % max. 1% min. % Approx VDC VDC Note 1. The rated current and coil resistance are measured at a coil temperature of 3 C with tolerances of +1%/-% for AC rated current and ±1% for DC coil resistance.. The inductances shown above are reference values. 3. Performance characteristic data are measured at a coil temperature of 3 C.. The maximum allowable coil refers to the maximum value in a varying range of operating power, measured at ambient temperature 3 C.. The "to" (for example "1 to 1") represents the range of rated s. Contacts Item Contact Form load -1A-T@ -1A-B@ Resistive load Inductive load (cosφ =.) Resistive load -A-T@ -A-B@ Inductive load (cosφ =.) Resistive load -1A-P -A-P Inductive load (cosφ =.) Contact type Double break Contact material Ag alloy Rated load 3 A at VAC A at VAC A at VAC A at VAC Rated carry current 3 A A A Max. switching VAC Max. switching current 3 A A A Note. When using B-series (screw) products, since the screw diameter of the contact terminal is M, be careful that the contact current should be A or less according to JET standard (electrical appliance and material control law of Japan). Characteristics Contact resistance *1 Operate time * Release time *3 Max. Mechanical operating frequency Rated load Insulation resistance *3 Between coil and contacts Between contacts Dielectric of same polarity strength Between contacts of different polarity (DPST-NO model) mω max. 3 ms max. 3 ms max. 1,8 operations/hr 1,8 operations/hr 1, MΩ min, VAC min., / Hz for 1 min, VAC, / Hz for 1min Impulse withstand 1, V between coil and contact * 1 to to 1 Hz,. mm Destruction single amplitude Vibration (1. mm double amplitude) resistance 1 to to 1 Hz,. mm Malfunction single amplitude (1. mm double amplitude) Shock Destruction 1, m/s resistance Malfunction 1 m/s Mechanical 1,, operations min. (at 1,8 operations/hr) Endurance 1, operations min. Electrical * (at 1,8 operations/hr under rated load) Failure rate (P level) (reference value *) 1 ma at VDC Approx. 9 g: Quick-connect terminal models Weight Approx. 1 g: PCB terminal models Approx. 1 g: Screw terminal models Note. The values given above are initial values. *1. Measurement conditions: VDC, 1 A, drop method. *. Measurement conditions: Rated operating applied, not including contact bounce. Ambient temperature: 3 C *3. Measurement conditions: The insulation resistance was measured with a -VDC megohmmeter at the same locations as the dielectric strength was measured. *. JEC-1 (1981) Standard Impulse Wave Type (1. μs). *. Ambient temperature: 3 C *. This value was measured at a switching frequency of operations/min. - C to C Ambient operating temperature (with no icing or condensation) Ambient operating humidity % to 8% Engineering Data -1A-T (TJ) (TUB) (TUBJ) -1A-B (BJ) (BUB) (BUBJ) Maximum Switching Power -A-T (TJ) (TUB) (TUBJ) -A-B (BJ) (BUB) (BUBJ) Maximum Switching Power -1A-P -A-P Maximum Switching Power Ambient Temperature vs. Operate and Release Voltage -1A VAC ( Hz) Switching current (A) AC inductive load (cosφ =.) AC resistive load Switching current (A) AC resistive load AC inductive load (cosφ =.) Switching current (A) 3 1 AC resistive load AC inductive load (cosφ =.) Operate and Release s (%) 1 8 Operate Release , , Switching (V) Ambient temperature ( C) Switching (V) Endurance Endurance Endurance -1A VDC Endurance (x 1 operations) 3 1 VAC resistive load 3 Endurance (x 1 operations) 3 1 VAC resistive load 3 Endurance (x 1 operations) 3 1 VAC resistive load 3 Operate and Release s (%) 1 8 Ambient temperature ( C) Operate Release VAC inductive load 1 (cosφ =.) 1 3 VAC inductive load 1 (cosφ =.) 1 3 VAC 1 inductive load (cosφ =.) Switching current (A) Switching current (A) Switching current (A) Ambient temperature ( C) 3

4 Ambient Temperature vs. Coil Temperature Rise -1A 1 VAC ( Hz) -1A VDC Shock Malfunction -A-T (TUB) 1 to 1 VAC Coil Temperature Rise ( C) 8 N= 3 A 1 A A Coil Temperature Rise ( C) 8 N= 3 A 1 A A X Z Y X' N = method: The value at which malfunction occurred was measured after applying shock to the test piece 3 times Z' each in directions along 3 axes. Standard: 1m/s Y X X' Z Ambient temperature ( C) Ambient temperature ( C) Y' Unit: (m/s ) Y' Shock direction Z' Momentary Voltage Drop -A-T (TUB) 1 to 1 VAC Circuit Wave resulted from test Ch1 (contact) ON Without chattering OFF Voltage distribution of wave e which chattering does not occur. of Relays 8 n=1 Ch1 Rated Ch (coil) e Ch 8 On the basis of rated (%) Characteristic variation resulted from different mounting directions -A-T (TUB) 1 to 1 VAC Operate time Release time Operate Release Time (ms) N = Operate time 1 1 Time (ms) 3 N = 3 Release time On the basis of rated (%) 8 N = Operate On the basis of rated (%) N = 3 Release 1 1 Top A A' B B' C C' A Top A' B B' C C' Top A A' B B' C C' Top A A' B B' C C' Bottom (Standard) (Note) Mounting direction Bottom(Standard) (Note) Mounting direction Bottom(Standard) (Note) Mounting direction Bottom(Standard) (Note) Mounting direction (Note.)The mounting direction A deteriorates switching performance. Actual Load Endurance -A 1 to VAC Operate and Release s N = On the basis of rated (%) 3 N = Operate Release Contact resistance Contact resistance (mω) 1 8 N = Operate and Release s N = On the basis of rated (%) 3 Operate Release N = Contact resistance Contact resistance (mω) N = Switching operations ( 1 operations) Switching operations ( 1 operations) Switching operations ( 1 operations) Load conditions Load conditions 1 φ VAC 1 φ VAC Switching operations ( 1 operations) A cosφ =. A cosφ =.9 (Compressor Lock ) A cosφ =..s 1s 1s Applied coil : 1% of rated.s 1s Applied coil : 1% of rated

5 -A 1 to VAC Operate and Release s N = Contact resistance Operate and Release s N = Contact resistance On the basis of rated (%) 3 N = Operate Release Contact resistance (mω) N = 3 On the basis of rated (%) 3 N = Operate Release Contact resistance (mω) N = Switching operations ( 1 operations) Switching operations ( 1 operations) Switching operations ( 1 operations) Load conditions Load conditions 1 φ VAC 1 φ VAC A cosφ =. Switching operations ( 1 operations) A cosφ = 1 A cosφ =. s 8s Applied coil : % of rated.s s 8s Applied coil : % of rated Dimensions E-bracket Mounting Quick-connect Terminals Note. E-brackets are sold separately. -1A-T.3. max.. max. 33. max..8 3 max. -A-T.3. max.. max. 33. max..8 3 max. 8 Two,.-dia. hole or M tapped -1A-TJ.3. max.. max. 33. max..8 ±.1 3 max. -A-TJ.3. max.. max. 33. max..8 3 max. 8

6 Adapter Mounting Quick-connect Terminals Note 1. The DIN Track Mounting Adapter and DIN tracks are sold separately.. The DIN Track Mounting Adapter can be track-mounted or screw-mounted. -1A-T PF-D 1. max.. max. 3 max.. max. -A-T PF-D 1. max. 8. max. 3 max.. max. Two, M or.-dia. -1A-TJ PF-D ±.1 1. max.. max. 3 max.. max. -A-TJ PF-D 1. max. 8. max. 3 max.. max. Front-connecting Socket Mounting Quick-connect Terminals Note 1. The Front-connecting Socket and DIN tracks are sold separately.. The Front-connecting Socket can be track-mounted or screw-mounted. -1A-T -M3. PF- 1. max.. max. -M 8 1. max. max. Two, M or.-dia. -A-T -M3. PF- ±.1 1. max. 8. max. -M 8 1. max. max.

7 -1A-TJ -M3. PF- 1. max.. max. -M 8 1. max. max. Two, M or.-dia. -A-TJ -M3. PF- ±.1 1. max. 8. max. -M 8 1. max. max. Upper Bracket Mounting Quick-connect Terminals -1A-TUB.3 8. max.. max. 33. max..8 max.. -A-TUB 8. max..3. max. 33. max..8 max. 8.. Two,.-dia. hole or M tapped -1A-TUBJ.3 8. max.. max. 33. max..8 ±. max... -A-TUBJ 8. max..3. max. 33. max..8 max. 8..

8 E-bracket Mounting Screw Terminals Note. E-brackets are sold separately. -1A-B -M3.. max.. max. 3. max. -M 8 max. -A-B -M3.. max.. max. 3. max. -M 8 max. 8 Two,.-dia. hole or M tapped -1A-BJ -M3.. max.. max. 3. max. -M 8 ±.1 max. -A-BJ -M3.. max.. max. 3. max. -M 8 max. 8 Adapter Mounting Screw Terminals Note 1. The DIN Track Mounting Adapter and DIN tracks are sold separately.. The DIN Track Mounting Adapter can be track-mounted or screw-mounted. -1A-B -M3. PF-D 1. max.. max. -M 8. max. 9 max. Note. Refer to page 1 for the coil internal Two, M or.-dia. -A-B -M3. PF-D ±.1 1. max. 8. max. -M 8. max. 9 max. Note. Refer to page 1 for the coil internal 8

9 -1A-BJ -M3. PF-D 1. max.. max. -M 8. max. 9 max. Two, M or.-dia. -A-BJ -M3. PF-D ±.1 1. max. 8. max. -M 8. max. 9 max. Upper Bracket Mounting Screw Terminals -1A-BUB -M3. 8. max.. max. 3. max. -M 8 9 max... -A-BUB -M3. 8. max.. max. 3. max. -M 8-1A-BUBJ.. 9 max. 8. max. -M3. -M 8. max. 3. max. 8 Two,.-dia. hole or M tapped ±. 9 max... -A-BUBJ -M3. 8. max.. max. 3. max. -M 8 9 max

10 PCB Mounting PCB Terminals -1A-P 1 max..8. max. 3. max..8 max. PCB (Bottom View) Tolerance: ±.1 mm (8.) square hole 1. (8.9) -A-P 1 max..8. max. 3. max..8 max. 3. PCB (Bottom View) Tolerance: ±.1 mm 3.8 (8.) square hole 1. (8.9) E-bracket R99- (E KANAU) FOR 1.8 Two,.-dia. hole Two, M or.-dia Adapter PF-D 1. max. Two, M or.-dia. ±.1 ± max. 3. max. Front-connecting Socket PF- -M3. 8±. 1. max. Two, M or.-dia. ±.1 -M 8 ±.1 9.±. max.. max. Cover PF-C 3. max.. max. 1 max. Put the PF-C cover onto the terminals in order to protect the user from electric shock. 1

11 Approved Standards A variety of Safety Standard approved products for standard models. UL approval (File No. E13) Contact ratings of test Coil ratings SPST-NO operations -1A-T@ -1A-B@ -1A-P -A-T@ -A-B@ -A-P 1 to VAC to VDC 3 A, VAC (RES) C 1, 1. kw, 1 VAC (T) C, 1. HP, 1 VAC C 1, 3 HP VAC C 1, FLA/1 LRA, 1 VAC C 1 FLA/1 LRA, VAC C 3, TV-1, 1 VAC C, CSA approval (File No. LR3198) Contact ratings of test Coil ratings SPST-NO operations. kw, 1 VAC (T) C, 1. HP, 1 VAC (T) C 1 to VAC 1, -1A-P 3 HP VAC C to VDC. FLA/1 LRA, 1 VAC 8 C 1, TV-1, 1 VAC C, -1A-T@ -1A-B@ -A-T@ -A-B@ -A-P 1 to VAC to VDC 3 A, VAC (RES) C 1,. kw, 1 VAC (T) C, 1. HP, 1 VAC C 3 HP VAC C 1,. FLA/1 LRA, 1 VAC 8 C 1, TV-1, 1 VAC C, Reference UL Approved Type... UL8 Industrial Control Devices UL19 Information processing equipment (Including office equipment) CSA Approved Type... CSA C. No.1, 1 Industrial Control Devices CSA C. No.9 Information processing equipment (Including office equipment) TÜV EN/IEC Standard Approved Type... EN181-1 Relay EN9 Information processing equipment (Including office equipment) IEC9 Information processing equipment (Including office equipment) EN/IEC, TÜV Approval (File No. R983) -1A-B@ -A-B@ -1A-T@ -A-T@ -1A-P -A-P Coil ratings, 1,, 8, 1,,, VDC 1,,, 1 to 1, to VAC Contact ratings SPST-NO 3 A, VAC ~ (cosφ = 1) C A, VAC ~ (cosφ =.) C 3 A, 1 VAC ~ (cosφ =.) C DPST-NO A, VAC ~ (cosφ = 1) C A, VAC ~ (cosφ =.) C SPST-NO A, VAC ~ (cosφ = 1) C A, VAC ~ (cosφ =.) C A, VAC ~ (cosφ = 1) C A, VAC ~ (cosφ =.) C DPST-NO A, VAC ~ (cosφ = 1) C A, VAC ~ (cosφ =.) C A, VAC ~ (cosφ = 1) C A, VAC ~ (cosφ =.) C SPST-NO A, VAC ~ (cosφ = 1) C A, VAC ~ (cosφ =.) C A, VAC ~ (cosφ = 1) C A, VAC ~ (cosφ =.) C DPST-NO A, VAC ~ (cosφ = 1) C A, VAC ~ (cosφ =.) C A, VAC ~ (cosφ = 1) C A, VAC ~ (cosφ =.) C Approved switching operations,,,,,,

12 Precautions Please refer to PCB Relays Common Precautions for general precautions. Correct Use Installation Although there are not specific limits on the installation site, it should be as dry and dust-free as possible. Using in an atmosphere of high temperature, high humidity and corrosive gas may deteriorate its performance characteristic caused by condensation or corrosive products, resulting in failure or burn damage of the Relay. PCB Terminal-equipped Relays weigh approximately 1 g. Be sure that the PCB is strong enough to support them. We recommend dual-side through-hole PCBs to reduce solder cracking from heat stress. Relays with test s must be mounted facing down. Be careful not to touch the test accidentally. Doing so may turn ON the contact. Be sure to use the test for test purposes only (with test- models). The test is used for Relay circuit tests, such as circuit continuity tests. Do not attempt to switch the load with the test. Micro Loads The is used for switching power loads, such as motor, transformer, solenoid, lamp, and heater loads. Do not use the for switching micro loads, such as signals. Soldering PCB Terminals Do not perform automatic soldering but solder manually. Do not wash down the entire Relay because it does not have an airtight construction. Connecting Refer to the following table when connecting a wire with a crimpstyle terminal to the. Coil Contact Screw terminals 8 M3. M Front-connecting Socket Allow suitable slack on leads when wiring, and do not apply excessive force to the terminals. Tightening torque Coil:.8 to 1.18 N. m Contact:.98 to 1.3 N. m 8 M3. M * The numbers shown in parentheses are for air-feeding. Note 1. The current should be A when using receptacle terminals. Note. Use receptacle terminals or positive housing for cable wiring. When connecting with screws, if the screws are not sufficiently tightened, the lead wire can become detached and may lead to abnormal heating or fire caused by faulty contact. Mounting Torque.98N. m Tighten with two M screws when mounting. (Top bracket type) Do not apply excessive force when mounting or dismounting the Faston receptacle.insert and remove terminals carefully one at a time. Do not insert terminals at an angle, or insert/remove multiple terminals at the same time. Do not connect to the terminals by soldering Type Receptacle terminals* Positive housing # terminals (width:.3 mm) Reference Data The ratio of rated between 1 to 1 VAC are values measured on the basis of 1 VAC. Operating Coil (Coil internal connections diagram) DC Coil AC Coil If a transistor drives the check the leakage current, and connect a bleeder resistor if necessary. The AC coil is provided with a built-in full-wave rectifier. If a triac, such as an SSR, drives the, the may not release. Be sure to perform a trial operation with the and the triac before applying them to actual use. AMP (13-1) AMP (138-1) AMP (139-1) AMP 1-1 natural color AMP 1- yellow AMP 1- green AMP 1- blue DIN Track Mounting Adapter and Front-connecting Socket (DIN Track Mounting) The DIN Track Mounting Adapter and Front-connecting Socket can be mounted on the with just one hand and dismounted with ease by using a screwdriver. To support the mounted on a DIN Track Mounting Adapter or Front-connecting Socket, use the PFP-M End Plate. Put the End Plate onto the DIN Track Mounting Adapter or Front-connecting Socket so that the surface mark of the End Plate faces upwards. Then tighten the screw of the End Plate securely with a screwdriver. (Screw Mounting) Screw-mount the DIN Track Mounting Adapter or Front-connecting Socket securely after opening screw mounting on them. When cutting or opening on the panel after the Front-connecting Socket is mounted, take proper measures so that the cutting chips will not fall onto the Relay terminals. When cutting or opening on the upper part of the panel, mask the Front-connecting Socket properly with a cover. 1

13 Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation Electronic and Mechanical Components Company Contact: Cat. No. J-E1-9 81()(O) 13

Model Number Structure

Model Number Structure Power Relay G7J Electromechanical Relays A High-capacity, High-dielectric-strength, Multi-pole Relay Used Like a Contactor Miniature hinge for maximum switching power for motor loads as well as resistive

More information

Mounting type Contact form PCB terminals Screw terminals Quick-connect terminals

Mounting type Contact form PCB terminals Screw terminals Quick-connect terminals Power Relay A High-capacity, High-dielectric-strength, Multi-pole Relay Used Like a Contactor Miniature hinge for maximum switching power for motor loads as well as resistive and inductive loads. No contact

More information

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A PCB Relay Miniature Single-pole Relay with 80-A Surge Current and 20-A Switching Current Ideal for motor switching. Miniature, relay with high switching capacity built-in applications. Creepage distance

More information

E bracket (see note 1) SPST-NO G7L-1A-TJ-CB G7L-1A-BJ-CB DPST-NO G7L-2A-T-CB G7L-2A-B-CB

E bracket (see note 1) SPST-NO G7L-1A-TJ-CB G7L-1A-BJ-CB DPST-NO G7L-2A-T-CB G7L-2A-B-CB General Purpose Relay G7L Ideally suited for high-inrush fluid pump controls: pool/spa, water processing, emergency, chemical industry, etc. High-capacity, high-withstand voltage relay with no contact

More information

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press Plug-In Safety Relay Safety Relay for Machine Control Conforms to EN Standard H Suitable for safety circuits in press machinery, machine tools, and other production machinery Do Not Remove H CE mark (conforms

More information

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC PCB Relay SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load Compact: 20 15 10 mm (L W H). Low power consumption: 200 mw. Flux protection or fully sealed construction available. Unique

More information

Ordering Information. Text PCB Power Relay G5LE

Ordering Information. Text PCB Power Relay G5LE A Cubic, Single-pole 10-A Power Relay Single-pole 10A 35VDC, 0.8mm contact gap: G5LE-G Single-pole 16A 250VAC: G5LE-E ROHS compliant. Sub-miniature sugar cube relay with universal terminal footprint. Conforms

More information

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment PCB Relay Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment High sensitivity can be driven by digital circuits. Horizontal design allows use in /2-inch PCB racks.

More information

PCB Relay. Single-side stable EN60950/EN41003 PCB terminal G6S-2 G6SU-2 G6SK-2 G6S-2-Y Surface mounting. stable

PCB Relay. Single-side stable EN60950/EN41003 PCB terminal G6S-2 G6SU-2 G6SK-2 G6S-2-Y Surface mounting. stable PCB Relay Surface Mounting DPDT Relay Long terminals for ideal for soldering and mounting reliability. Space-saving inside-l terminal. High dielectric strength between coil and contacts (2,000 VAC), and

More information

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays Low-profile Relay with Various Models Low profile:.7 mm in height Clearance and creepage distance Between coil and contacts: 8 mm/8 mm Between contacts of the same polarity: 3 mm/4 mm Models with AC coil

More information

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information with the World s Smallest Mounting Area Subminiature model as small as.2 (H). (W) (L) mm is ideal for high-density mounting ((U)-2F(-Y)). Low profile of.2 mm improves mounting efficiency ((U)-2F(-Y)).

More information

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC PCB Relay Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications Compact, yet capable of switching up to 30-A loads. Complies with UL873 and UL508 column A spacings (1/8 through

More information

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC Power PCB Relay G6D-ASI Reduced board space ideal for high-density mounting (45% smaller than the surface area of G6B). Slim package: measures 6.5 W x 17.5 L x 12.5 H mm Switches loads up to 5 A, 250 VAC/30

More information

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed PCB Relay G5LA A Cubic, Single-pole 1A Power Relay Economical cube relay with universal terminal footprint Conforms to VDE435, CQC UL recognized/ CSA certified. High switching power: 1A @ 5VAC Withstands

More information

Model Number Structure

Model Number Structure Terminal Relay G6B-4@@ND Compact Terminal Relay with 4 Independent Outputs Equipped with four G6B Mini-relays that are compact, highly sensitive, and highly resistant to dielectric surges, and that can

More information

PCB Relay. Contact form Terminal Single-side stable Single-winding latching

PCB Relay. Contact form Terminal Single-side stable Single-winding latching PCB Relay Subminiature, Sensitive SPDT Signal Switching Relay High sensitivity: 98 mw pickup coil power. Impulse withstand voltage meets FCC Part 68 requirements. Plastic-sealed construction. Unique moving

More information

G7S Safety Relay. Ordering Information. Safety Relay conforming to EN standard G7S. Accessories Safety Relay Sockets

G7S Safety Relay. Ordering Information. Safety Relay conforming to EN standard G7S. Accessories Safety Relay Sockets Safety Relay Safety Relay conforming to EN standard Conforms to pren50205. A minimum of 0.5 mm between contacts even when one contact is welded. (pren50205 Class A) Forcibly guided contacts. The contributes

More information

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC PCB Relay Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications Compact, yet capable of switching up to 30-A loads. Complies with UL873 and UL508 column A spacings (1/8 through

More information

D2VW. Sealed Miniature Basic Switch Conforms to IP67 (Excluding the terminals on terminal models) Model Number Legend. Sealed Miniature Basic Switch

D2VW. Sealed Miniature Basic Switch Conforms to IP67 (Excluding the terminals on terminal models) Model Number Legend. Sealed Miniature Basic Switch Sealed Miniature Basic Switch Conforms to IP67 (Excluding the terminals on terminal models) Use of epoxy resin assures stable sealing, making this switch ideal for places subject to water spray or excessive

More information

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL Terminal Relay Easy-to-use, Space-saving Terminal Relay with Four-point Output Almost the same size as PYF Socket: 31 x 35 x 68 mm (W x H x D) Each terminal circuit (with coil or contact) is independent

More information

Single-pole 10A35VDC 0.8mm Contact Gap Power Relay : G5LE-G Single-pole 16A250VAC Power Relay : G5LE-E. Contact Form 10A 35VDC

Single-pole 10A35VDC 0.8mm Contact Gap Power Relay : G5LE-G Single-pole 16A250VAC Power Relay : G5LE-E. Contact Form 10A 35VDC PCB Relay R G5LE-E/-G Single-pole 0A35VDC 0.8mm Contact Gap Power Relay : Single-pole 6A250VAC Power Relay : G5LE-E Sub-miniature 'sugar cube ' relay with universal terminal footprint. UL class-f coil

More information

Type Contact form Model Plug-in socket/solder terminals Hermetically sealed 4PDT MY4H-US

Type Contact form Model Plug-in socket/solder terminals Hermetically sealed 4PDT MY4H-US Hermetically Sealed Relay MY4H Hermetically Sealed Relay Ideal for Hazardous Locations Class 1 Division 2 approved. Fully hermetically sealed for hazardous locations. Cadmium-free contacts for environment-friendly

More information

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries Safety Relay Unit Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries Two-pole slim models that are only 22.5 mm wide, three-pole models that are only 68 mm wide,

More information

Ordering Information. Text Surface-Mounting Signal Relay G6K

Ordering Information. Text Surface-Mounting Signal Relay G6K Surface-Mounting Relay with the World s Smallest Mounting Area and a Height of Only 5.2 mm ROHS compliant. Sub-miniature model as small as 5.2 (H) x 6.5 (W) x 10 (L) mm is ideal for high-density mounting.

More information

PCB Relay. Ordering Information. Surface Mounting DPDT Relay G6S

PCB Relay. Ordering Information. Surface Mounting DPDT Relay G6S PCB Relay Surface Mounting DPDT Relay Long terminals for ideal for soldering and mounting reliability. Space-saving inside-l terminal. High dielectric strength between coil and contacts (2,000 VAC), and

More information

PCB Relay. New G8P. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

PCB Relay. New G8P. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC PCB Relay Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications Compact, yet capable of switching up to 30-A loads. Complies with UL873 and UL508 column A spacings (1/8 through

More information

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend ealed ubminiature Basic witch ealed ubminiature Basic witch Conforming to IP67 (Excluding the terminals on terminal ) Use of epoxy resin assures stable sealing, making this switch ideal for places subject

More information

3. Terminal Shape P : PCB terminals FS: Surface-mounting terminals, short FL : Surface-mounting terminals, long

3. Terminal Shape P : PCB terminals FS: Surface-mounting terminals, short FL : Surface-mounting terminals, long Surfacemounting Relay Ultracompact and Slim DPDT Relay Suitable for highdensity mounting.(.7 mm (W). mm (L) 9 mm (H)). Dielectric strength of, VAC and an impulse withstand voltage of 2, V for 2 μs (conforms

More information

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24 Solid State Relays (SSRs) G3PA/G3PB Long Service Life for Circuits that Cycle Frequently D D D D D Built-in heat sink increases life and reliability Voltage turn-on at zero crossing reduces initial inrush

More information

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend ealed ubminiature Basic witch ealed ubminiature Basic witch Conforming to IP67 (Excluding the terminals on terminal ) Use of epoxy resin assures stable sealing, making this switch ideal for places subject

More information

Power PCB Relay. Type Contact material Contact form Construction Part number General purpose AgCdO SPDT Semi-sealed G2R-1

Power PCB Relay. Type Contact material Contact form Construction Part number General purpose AgCdO SPDT Semi-sealed G2R-1 Power PCB Relay Creepage distance of 8.0 mm (0.31 in) min. between coil and contact Dual-winding latching type available Plug-in and quick-connect terminals available High sensitivity (360 mw) and high

More information

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g. Tactile Switch BW Tactile Switch with Sealed Construction for Automatic Soldering Sealed construction conforming to IP67 (IEC-6059) provides high reliability in locations exposed to dust or water. Available

More information

PCB Relay. 2. Contact Form 2: DPDT 3. Terminal Shape None: PCB terminal F: Surface mount terminal

PCB Relay. 2. Contact Form 2: DPDT 3. Terminal Shape None: PCB terminal F: Surface mount terminal PCB Relay Ultracompact, Ultrasensitive DPDT Relay Compact size and low 5-mm profile. Low power consumption (140 mw for single-side stable, 100 to 300 mw for latching type) and high sensitivity. Low thermoelectromotive

More information

D2D. Door Interlock Power Switch with Minimum Contact gap of 3 mm. Model Number Legend. Contact Form. List of Models. Contact Specifications.

D2D. Door Interlock Power Switch with Minimum Contact gap of 3 mm. Model Number Legend. Contact Form. List of Models. Contact Specifications. Power/oor Switch oor Interlock Power Switch with Minimum Contact gap of mm Offers the minimum contact gap of mm required for power switches as standard equipment. Safety considerations include a double

More information

10 AMP POWER RELAY. Breakdown voltage* 2. Operate time* 3 (at nominal voltage) Shock resistance. Vibration resistance. Unit weight

10 AMP POWER RELAY. Breakdown voltage* 2. Operate time* 3 (at nominal voltage) Shock resistance. Vibration resistance. Unit weight VDE 2c, 3c AMP POWER RELAY RELAYS 2. 1.72 FEATURES Interchangeable with existing models Long life and high reliability High contact capacity up to A 20 Available with plug-in/solder and quick-connect terminals

More information

PCB Relay RC+ Ordering Information. Subminiature Relay that Switches up to 5 A G6B VDC

PCB Relay RC+ Ordering Information. Subminiature Relay that Switches up to 5 A G6B VDC PCB Relay Subminiature Relay that Switches up to 5 A Subminiature: 20 10 10 mm (L W H). Low power consumption: 200 mw. Unique moving loop armature reduces relay size, magnetic interference, and contact

More information

Ordering Information. Motor Timer H2A. Miniature, High-performance Motor. Motor Timer H2A 1

Ordering Information. Motor Timer H2A. Miniature, High-performance Motor. Motor Timer H2A 1 Motor Timer H2A Miniature, High-performance Motor Timer Employs high-reliability bifurcated contacts for output. Moving pointer provided in all types for confirmation of elapsed time. Employs time-out

More information

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2 Solid-state Contactor (New Heat Sink Construction) G3PB Space and working time saved with new heat sink construction. Series now includes 480-VAC models to allow use in a greater range of applications.

More information

Low Signal Relay. To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12).

Low Signal Relay. To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12). Low Signal Relay High sensitivity can be driven by digital circuits Low-profile design allows use in 12.70 mm (0.50 in) PC board rack Surge withstand voltage meets FCC Part 68 regulation Units can be mounted

More information

D2SW-AQ. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

D2SW-AQ. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal ) Use of epoxy resin assures stable sealing, making this switch ideal for places subject to water spray or excessive

More information

D2MV. Highly reliable Miniature Basic Switch in spite of its Ultra-low Load action. Model Number Legend. List of Models.

D2MV. Highly reliable Miniature Basic Switch in spite of its Ultra-low Load action. Model Number Legend. List of Models. Highly reliable iniature Basic Switch in spite of its Ultra-low Load action Twin crossbar contact employed for exceptionally high contact reliability. Unique internal mechanism that ensures high contact

More information

DPDT BTA12-2C-S-C BTA12-2C-S-CL BTA12-2C-S-CLM SPST-NO-DM BTA12-1X-S-C BTA12-1X-S-CL BTA12-1X-S-CLM

DPDT BTA12-2C-S-C BTA12-2C-S-CL BTA12-2C-S-CLM SPST-NO-DM BTA12-1X-S-C BTA12-1X-S-CL BTA12-1X-S-CLM FEATURES Plug-in relay Quick connect receptacles or direct soldering. PCB terminals are also acceptable. Large capacity 30A contact rating. Optional blowout magnet: high dc switching. Wide spacing between

More information

D2AW. Long stroke seal switch with high reliability and high insulation performance. Model Number Legend. Sealed Ultra Subminiature Basic Switch

D2AW. Long stroke seal switch with high reliability and high insulation performance. Model Number Legend. Sealed Ultra Subminiature Basic Switch Long stroke seal switch with high reliability and high insulation performance Double reliability by twin contacts (=Clipping contact). Foreign materials are cleaned out by the sliding

More information

Subminiature Basic Switch

Subminiature Basic Switch Subminiature Basic Switch Subminiature Basic Switch Offers Long Life and High Reliability A design that combines simplicity and stability by the use of two split springs ensures a long durability of 30,000,000

More information

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from Omron STI Application Support Thank you for your interest in Omron STI products. Please contact Omron STI with your application questions. Support Engineers are available at our USA headquarters from 4:00

More information

Model Number Structure

Model Number Structure Small Sealed Switch D4E-@N Slim and Compact Switch with Better Seal and Ensuring Longer Service Life than D4E Flat springs with an improved lever ratio of the built-in switch ensure smooth snap action

More information

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit SSR with Failure Detection Function Detects failures in SSRs used for heater temperature control and simultaneously outputs alarm signals. This product supports the safe design of heater control systems,

More information

G9SA-TH. Two-Hand Controller. Ordering Information. Specifications. 45-mm Wide Two-hand Control Circuit. H Two-hand Controller, easy-to-connect

G9SA-TH. Two-Hand Controller. Ordering Information. Specifications. 45-mm Wide Two-hand Control Circuit. H Two-hand Controller, easy-to-connect Two-Hand Controller -mm Wide Two-hand Control Circuit H Two-hand Controller, easy-to-connect Expansion Units available H Positive, force-guided contacts H DIN-rail mounting and panel mounting available

More information

General Purpose Relay

General Purpose Relay General Purpose Relay Exceptionally reliable general purpose relay Long life (minimum 100,000 electrical operations) assured by silver contacts Built-in operation indicator (mechanical, LED), diode surge

More information

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information Safety-door Switch Safety-door Switch s Special Operation Key Directly Pulls Apart the Contacts from Each Other and Contributes to the Safety of the Production Site Conforms to EN (TÜV) standards corresponding

More information

AC 250V AC 250V AC 250V AC 250V DC 110V DC 110V DC 110V DC 110V Max. Allowable Current 15A 10A 10A 10A

AC 250V AC 250V AC 250V AC 250V DC 110V DC 110V DC 110V DC 110V Max. Allowable Current 15A 10A 10A 10A Main Feature 1. 1 Pole to 4-Poles versions available with switching current at 15A (1 Pole) and 10A (2-4 Poles). 2. Printed Circuit Board Terminal, Plug-in Terminal and Flanged Case are designed for easy

More information

2c 15A, 4c 10A polarized power relays

2c 15A, 4c 10A polarized power relays c 5A, 4c A polarized power relays SP RELAYS RoHS compliant Protective construction: Dust cover type Taking advantage of the 4-gap balanced armature mechanism, S relays have met a number of relay needs

More information

Tactile Switch. Ordering Information. A Wide Range of Models: 6 x 6 mm, 12 x 12 mm, Vertical, and High-force.

Tactile Switch. Ordering Information. A Wide Range of Models: 6 x 6 mm, 12 x 12 mm, Vertical, and High-force. Tactile Switch A Wide Range of Models: 6 x 6 mm, 1 x 1 mm, Vertical, and High-force. A positive click action plus a long life equal to that of a no-contact switch. Radial models (taping specifications)

More information

Features. Type List. Ordering Information S - 1A - - C - Contact Rating

Features. Type List. Ordering Information S - 1A - - C - Contact Rating Features Heavy duty A VAC, A VAC power type. AC & DC coils are both available. PCB terminals and quick terminal types. Optional for special large contact gap 3.0mm version. SPNO-ST & DPNO-ST contact configuration.

More information

Mechanical Key Switch

Mechanical Key Switch Mechanical Key Switch B3F A Wide Range of Models: 6 x 6 mm, 12 x 12 mm, Vertical and High-force. Excellent tactile feel combined with high life expectancy. Available in stick packaging for automatic mounting

More information

Wire. Socket (with polarizing guide) Wire can be connected without stripping cable insulation. IDC contacts. Rise in temperature ( C)

Wire. Socket (with polarizing guide) Wire can be connected without stripping cable insulation. IDC contacts. Rise in temperature ( C) IDC Connectors for Discrete Wires Trouble-free discrete-wire termination with IDC Sockets that accommodate MIL Plugs. XG5 * Two-slot, IDC construction and insulation barrel offer high reliability and large-current

More information

Model Number Structure

Model Number Structure Solid State Relays (Single-phase) G3PB New Single-phase Solid State Relays with Compact Size for Heater Control Slim models with a thickness of only 22.5 mm are also available. Compact design achieved

More information

Ordering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31

Ordering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31 Snap Action Switch Subminiature Snap Action Switch Switches 3 A loads (general-purpose), 1 A loads (low force general-purpose) and 0.1 A loads(microvoltage/ microcurrent) Long life span assured by high-precision

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit   Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Force-Guided s & Power Contactors For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Multi-pole Power for Contactor Current

More information

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm Emergency Stop Switch Mounting Aperture of 16 mm Modular construction, easy installation Positive opening mechanism with minimum contact separation of 3 mm in accordance with EN60947-5-1, Conforms to EN418

More information

HEAVY DUTY POWER RELAYS FEATURES

HEAVY DUTY POWER RELAYS FEATURES VDE VC HEAVY DUTY POWER RELAYS VC RELAYS Faston terminal Screw terminal mm 9 FEATURES VC power relays are designed for controlling heavy duty loads safely: Contact gap of 3 mm or more -point contacts for

More information

Type Terminal Coil Contact form Model

Type Terminal Coil Contact form Model General Purpose Relay MK Exceptionally reliable general purpose relay. Long life (minimum 100,000 electrical operations) assured by silver contacts. Built-in operation indicator (mechanical, LED), diode

More information

General Purpose Relay

General Purpose Relay General Purpose Relay Designed small, 2- and 3-pole types break 5 A loads and 4-pole type, 3 A load High reliability, long life Ultra-high sensitivity with quick response High vibration/shock resistance

More information

The full feature relay includes the combination for rotary button or plain button or light or indicator flag.

The full feature relay includes the combination for rotary button or plain button or light or indicator flag. FEATURES 3A / 5A/10A of general purpose relay DPDT and 3PDT and 4PDT contact arrangement Bifurcated contact: To increase contact reliability Flag indicator: Shows relay status or power condition L.E.D.

More information

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9. Compact Interlock Safety Door Switch Compact Safety Switch Saves Space and is Ideal for a Variety of Doors Positive opening mechanism and double insulation approved by TÜV and BIA. Five-direction Operation

More information

General Purpose Relay

General Purpose Relay General Purpose Relay Arc barrier equipped High dielectric strength (2,000 VAC) Long dependable service life assured by AgCdO contacts Choose models with single or bifurcated contacts, LED indicator, diode

More information

Standard Plug-in/solder SPDT LY1 LY1F DPDT LY2 LY2F LY2Z LY2ZF 3PDT LY3 LY3F 4PDT LY4 LY4F PCB SPDT LY1-0 DPDT LY2-0 LY2Z-0

Standard Plug-in/solder SPDT LY1 LY1F DPDT LY2 LY2F LY2Z LY2ZF 3PDT LY3 LY3F 4PDT LY4 LY4F PCB SPDT LY1-0 DPDT LY2-0 LY2Z-0 General Purpose Relay LY Arc barrier equipped. High dielectric strength (2,000 VAC). Long dependable service life assured by Ag-Alloy contacts. Choose models with single or bifurcated contacts, LED indicator,

More information

Sealed type washable 1C H-1C-C 812H-1C-V 812H-1C-S (SPDT) F 812H-1C-C F 812H-1C-V F 812H-1C-S F

Sealed type washable 1C H-1C-C 812H-1C-V 812H-1C-S (SPDT) F 812H-1C-C F 812H-1C-V F 812H-1C-S F 8H Type List 8H Terminal style Contact form Features Miniature PCB Power Relays A 2VAC. High CTI 2 material or product comply with IEC 33-1 are available. UL Insulation Class F. VDE, UL/CUL, TUV, CSA/CUS

More information

Small Limit Switch D4V

Small Limit Switch D4V Small Limit Switch DV Compact Vertical Models Sized for Asian Standards Compact new design approximately / the size of OMRON vertical Limit Switches. Structure enables the terminal section to be fully

More information

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information D2SW-P

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information D2SW-P Sealed Subminiature Basic Switch Sealed Basic Switch with Simplified Construction, Mounting Compatible with SS and D2SW Series. Sealing by using rubber packing means the switch can be used in dust-proof

More information

Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models

Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models Enclosed Switch Economical, High Utility Enclosed Switch High precision and long life (10,000,000 mechanical operations) through employment of the moving spring used in OMRON Z Basic Switch. Sealed with

More information

1 Form A 5A small size power relay for interface

1 Form A 5A small size power relay for interface 1 Form A 5A small size power relay for interface PQ RELAYS RoHS compliant Protective construction: Sealed type FEATURES 1. Compact and slim 20 mm (L) mm (W) 16 mm (H).787 inch (L).394 inch (W).630 inch

More information

A165S/W. Separate Construction with Cylindrical 16-dia. Body. Knob-type Selector Switch (Detachable) (Cylindrical 16-dia.

A165S/W. Separate Construction with Cylindrical 16-dia. Body. Knob-type Selector Switch (Detachable) (Cylindrical 16-dia. Knob-type Selector Switch (Detachable) (Cylindrical 16-dia.) CSM_A165S_W_DS_E_4_1 Separate Construction with Cylindrical 16-dia. Body Same separate construction as the A16-series Pushbuttons with Miniature

More information

Frequency 10 to 55 Hz, Amplitude 0.75mm Frequency 10 to 55 Hz, Amplitude 0.75mm. Frequency 10 to 55 Hz, Amplitude 0.75mm

Frequency 10 to 55 Hz, Amplitude 0.75mm Frequency 10 to 55 Hz, Amplitude 0.75mm. Frequency 10 to 55 Hz, Amplitude 0.75mm Power Relays RL Series PRODUCT DESCRIPTION Quick Connect Flange Mount SPECIFICATIONS Number of poles pole 2 poles Contact Configuration X (SPST, double make) 2X (DPST, double make) Contact material Ag

More information

TL RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, etc. ORDERING INFORMATION TYPES. High Load Relay for Smart Junction Box ACTL.

TL RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, etc. ORDERING INFORMATION TYPES. High Load Relay for Smart Junction Box ACTL. High Load Relay for Smart Junction Box TL RELAYS High heat-resistant type: Sealed Pin in Paste compliant type: Flux tight New 14.4.7 11.433 1.3 FEATURES Large capacity switching

More information

A22NK. Key-type Selector Switches

A22NK. Key-type Selector Switches Key-type Selector Switches -mm dia. Key-type Selector Switches Control panel miniaturization through a more compact design and modified wiring direction. Addition of Push-In Plus terminal blocks for easy

More information

Lighted Pushbutton Switch

Lighted Pushbutton Switch Lighted Pushbutton Switch General Purpose and Micro-Voltage/Current Load Switch Requires only 22 mm mounting depth All LEDs, lamps, legends and pushbutton units replaceable without tools Oil-resistant

More information

Safety-door Switch. Ordering Information

Safety-door Switch. Ordering Information Safety-door Switch Safety-door Switch s Special Operation Key Positively Pulls Apart the Contacts from Each Other and Contributes to the Safety of the Production Site Special Operation Key prevents mis-operation.

More information

Surface mounting, flush mounting, and DIN track mounting

Surface mounting, flush mounting, and DIN track mounting Solid-state Timer H3JA Economical, Compact, Plug-in Timer Time limit, ON-delay, operation with automatic resetting. DIN size (36 x 36 mm), fits standard 8-pin sockets. Wide choice of supply voltages: 24,

More information

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h) Mechatronic Analog Timer H3AM Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty and

More information

Type Plunger Switch height Operating force Model Without ground terminal With ground terminal. 5.0 mm General-purpose: 100 g 150 g

Type Plunger Switch height Operating force Model Without ground terminal With ground terminal. 5.0 mm General-purpose: 100 g 150 g Tactile Switch BF Miniature, Space-Saving Tactile Switch Provides Long Service Life and Easy Mounting Extended mechanical/electrical service life: 0 x 0 6 operations for x mm type and x 0 6 operations

More information

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet Small Sealed Switch D4E-N CSM_D4E-_N_DS_E_4_ Slim and Compact Switch with Better Seal and Ensuring Longer Service Life than D4E Flat springs with an improved lever ratio of the built-in switch ensure smooth

More information

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure. Guard Lock Safety-door Switch Protective Doors Are Locked Until Machines Completely Stop Operating A mechanical lock is applied automatically when the Operation Key is inserted. A high level of safety

More information

Tactile Switch (Hinged Type)

Tactile Switch (Hinged Type) Tactile Switch (Hinged Type) Hinged Design Developed through Ergonomics Quick, superior snap action through hook-type hinge construction. Available with 1 or LEDs or without LEDs. The hinge button is available

More information

TV-5, TV-8 rated 10mm flat power relays Silent type is available

TV-5, TV-8 rated 10mm flat power relays Silent type is available TV-, TV- rated 1mm flat power relays Silent type is available LK-F RELAYS TV standards compatible: TV- and TV- TV- type: 7 A inrush current and switching possible at A rated current. : 11 A inrush current

More information

Power Contactor with Mirror Contacts

Power Contactor with Mirror Contacts LLAME SN COSTO Force-Guided Relays Power Contactor with Mirror Contacts Contents Selection Guide 2 Force-Guided Relays G7SA G7S- -E 3 8 Power Contactor with Mirror Contacts J7KNA-AR G7Z 11 15 1 LLAME SN

More information

15A (2 Form C), 10A (4 Form C) COMPACT POWER RELAYS WITH HIGH SENSITIVITY

15A (2 Form C), 10A (4 Form C) COMPACT POWER RELAYS WITH HIGH SENSITIVITY 5A ( Form C), A (4 Form C) COMPACT POWER RELAYS WITH HIGH SENSITIVITY RELAYS RoHS Directive compatibility information http://www.mew.co.jp/ac/e/environment/ Taking advantage of the 4-gap balanced armature

More information

Features. Emergency Stop Switch A22E. Install in 22-dia. or 25-dia. Panel Cutout. Safety Lock Mechanism to Prevent Misuse.

Features. Emergency Stop Switch A22E. Install in 22-dia. or 25-dia. Panel Cutout. Safety Lock Mechanism to Prevent Misuse. Switch A22E Install in 22-dia. or 25-dia. Panel Cutout Direct opening mechanism to open the circuit when the contact welds. Safety lock mechanism prevents operating errors. Easy mounting and removal of

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Safety Interlock Switches D4S-N D4SN For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Slim Safety Door Switches with

More information

General Purpose Relay

General Purpose Relay General Purpose Relay KML 15A switching capability 1.5kV dielectric strength (between coil and contacts) Various terminals available Socket available 1 to 3 pole configurations 1. COIL DATA (at 23 ) 1)

More information

Hinged Safety Door Switch

Hinged Safety Door Switch Hinged Safety Door Switch Polymer housing, IP65, and slow-action contacts with positive opening. Two actuator types are available: Shaft Arm lever Arm lever type can be adjusted to allow a right (180 ),

More information

Input terminals Isolation method Zero cross function Operation indicator Alarm output Applicable load (See note.) Model

Input terminals Isolation method Zero cross function Operation indicator Alarm output Applicable load (See note.) Model Solid State Relays with Built-in Current Transformer CSM DS_E_7_ A New-concept SSR with Built-in Current Transformer. Heater Burnout and SSR Shortcircuit Failure Detection. Built-in Current Transformer

More information

A165-E. Ordering Information. Emergency Stop Switch. For Panel Cutout of 16 mm

A165-E. Ordering Information. Emergency Stop Switch. For Panel Cutout of 16 mm Emergency Stop Switch For Panel Cutout of 16 mm H Modular construction, easy installation H Positive opening mechanism with a minimum contact separation of 3 mm in accordance with EN6947-5-1, for NC contacts

More information

B3F. Miniature, Space-saving Switch

B3F. Miniature, Space-saving Switch B3F Miniature, Space-saving Switch Long mechanical / electrical service life Ideal for applications such as audio, office and communications equipment, TVs, etc Taped radial, vertical, high-force, and

More information

Type List. Standard Type. High Power Type

Type List. Standard Type. High Power Type Features 8A/1 miniature PCB Power Relay. Large contact gap : 2mm/. High dielectric strength and comply with IEC 16950. Epoxy seal type and sealed flux free are both available. Design for UPS and power

More information

Switching Power Supply

Switching Power Supply Switching Power Supply Miniature DIN-track Mounting DC-DC Power Supplies 3- and 7.5-W models. Inputs: 10 to 27 VDC (DC input) Outputs: 5, 12, 15, 24, ±12, and ±15 V. 65 mm depth enables mounting onto panels

More information

G3PE-Single-phase. Solid State Relays for Heaters

G3PE-Single-phase. Solid State Relays for Heaters Solid State Relays for Heaters Single-phase Compact, Slim-profile SSRs with Heat Sinks. Models with No Zero Cross for a Wide Range of Applications. RoHS compliant. Models also available with no zero cross

More information

Model Number Legend (Completely Assembled)... Shipped as a set which includes the Operation Unit, Lamp (lighted models only), and Switch. 4.

Model Number Legend (Completely Assembled)... Shipped as a set which includes the Operation Unit, Lamp (lighted models only), and Switch. 4. Emergency Stop Switch (-dia./5-dia.) AE CSM_AE_DS_E_7_ Install in -dia. or 5-dia. Panel Cutout Direct opening mechanism to open the circuit when the contact welds. Safety lock mechanism prevents operating

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Emergency Stop Devices A22E A22E For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Emergency Stop Switch (22 mm or 25

More information

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC Solid State Relays G3NB with 40-A output at a reasonable price. Switches 9 A without a heat sink. Zero cross function enables less noise operation. Built-in varistor effectively absorbs external surges.

More information