Low Voltage Products. ABB Building Technologies. PowerLine OS and OESA Switch Fuses. Brochure OS-OESA 1 GB 00-05

Size: px
Start display at page:

Download "Low Voltage Products. ABB Building Technologies. PowerLine OS and OESA Switch Fuses. Brochure OS-OESA 1 GB 00-05"

Transcription

1 Low Voltage Products PowerLine S and ESA Switch Fuses Brochure S-ESA 1 GB ABB Building Technologies

2 < < Fuse Protection - Easy and Reliable Complete range of switch fuses 20A to 800A, 690V S and ESA The fuse is a superior short circuit protecting element regarding the maximum allowed cut-off current (peak let through current) and energy value. This is more important the higher the voltage and prospective fault levels are. The PowerLine switch fuses fulfil the highest requirements for modern switch fuses with a total safety concept. The switch fuses are tested according to the EC (EN ) standard with more strigent requirements for isolation, breaking, making, performance and safety. 8ya(6x7y)3 Easy and economical selectivity Fuse links provide a simple procedure for selecting the right fuse type for your installation, without complicated calculations. Fuses prevent "blackouts". nly the fuse nearest a fault trips without upstream fuses (feeders or mains) being affected. Fuses thus provide selective coordination. Superior Features 2

3 Fuse Protection - Easy and Reliable Economical nstallation Life time costs of fuse systems are low. Fuse links which can withstand a high fault level and a fault current are available at economical prices. After tripping, only the fuse-link has to be changed. No arc space - No emission Fused Because the fuse links can be rapidly and easily replaced, plant down-time and maintenance are substantially reduced with a fuse link system. Because the fusing elements operate in a cylinder, they are not affected by their surroundings. Thus their protecting characteristics remain stable year after year. Non Fused 0 No need to change the present structure when more power is needed Second transformer is connected in parallel => Required short-circuit breaking capacity of devices grows. No problems with fused system. CCA CCA 4 Superior Features CCB CCB CCB

4 Fuse Protection - Easy and Reliable A reliable protection is costeffectively achieved with fuse links Acc. to EC (EN ) standard regarding motor starters, certain coordination categories of the protection are defined. Coordination type 1 allows damage to a contactor and a thermal overload relay after a short-circuit. An operator shall inspect the starter afterwards and the apparatus may need to be replaced. Failure to do this means the circuit is not protected against overload which can lead to a motor damage and a cable fire. Coordination type 2 guarantees that the starter is in full operation after a short-circuit. The fuse-links offer a type 2 category protection even at 690 V. With breakers, to achieve a coordination type 2, problems arise especially at higher voltages. Generally it can be said that particularly at higher voltages, the fuse system is stronger. Clear coordination tables, Type 2 400V type 2 80kA 500V type 2 50kA 690V type 2 50kA min. up to 80kA/50kA peration time Rated current of a motor Motor starter coordination verload relay Starting current of a motor 0 6 The breaking capacity of the contactor Fuse Contactor, thermal overload relay and fuse in a motor circuit. Damaging area of thermal relay Welding area of the contactor contacts Current / n With the fuses the short circuit protection of coordination type 2 can be easily ensured without over-dimensioning the components. Fused Motor Control M 3~ 6 M M M Superior Features Fuse monitor

5 PowerLine Switch Fuses The switch fuse combines a fused short circuit protection with load break switching on both sides of the fuse link. The fuse links are mechanically stationary elements, ensuring a long electrical and mechanical life for both AC and DC- networks in a minimum panel space. The selectivity is easily achieved with subsequent fuses. The standard fuses withstand 100 ka fault current, which means less variations and problems in selection of the components. Complete range of switch fuses from 20A to 800A, 690V Switch fuses are available for all types of fuse links, DN, BS, NFC, UL, CSA. New features within the range of ABB Switch fuses include; single pole to four pole versions, the switch fuse mechanism can now be located in any position together with the direction of the terminals, increasing the ease of installation and adaptability to different types of cubicle designs. 6 and 8- pole, changeover, by-pass and mechanically interlocked switch combinations can be built up by means of optional conversion kits. See brochure ESA 2 GB. Reliable solation The PowerLine switch fuses are tested as switch disconnectors according to the EC The isolation is reliable even after short circuit throughout the lifetime of the switch fuse. Compliance with the new machine directives EC 204 (EN 60204) The rated impulse withstand voltage (U imp ) exceeds the 12 kv level allowing a free installation for all physical environments, system voltages and installation categories. Visible contacts Reliable position indication Reliable position indication in the handle and mechanism eliminates risks even in the case of welded contact. The handle does not reach the FF- position, if the contacts are welded together. The handle returns towards the N- position maintaining the interlock of the door. The fuse is an active element in the short circuit. The switch fuse as a passive element remains intact. 8

6 PowerLine Switch Fuses S A and ESA_PL, A Contents: Switch Fuses S A General Technical data rdering information Dimension drawings Contact Functions Switch Fuses ESA_PL, A General Technical data rdering information Dimension drawings Contact Functions

7 New Switch Fuse Range 12

8 Total user safety Total user safety Fuse carriers fully P20 protected The fuse covers cannot be opened while the switch fuse is in the N position Patented, operator-independent quick make/quick break mechanism Fuse links are isolated on both sides of the fuse Fully-protected construction, P 20, in types S for both cable terminals and fuses, optional P30 terminal shrouds in S 160 types Various types for world-wide applications: Suitable fuses: DN, sizes : A, BS88, F1, A1-A4: A NFC (French): A UL (U.S.A.) and CSA (Canada), Class J, A, class CC, A CSA, class C, A Flexible mounting options Mounting on the 35 mm in S Mini, 35 mm or 75 mm in S DN rail or with screws to the mounting plate Symmetrical construction, enabling an upside-down mounting A mounting screw hole template is printed on the box P 20 snap-on mounted single blocks N.. contacts with positive opening feature contacts for easy commissioning Auxiliary contacts_ max 1+1 ( contacts) Unique patented design for the 21st century The new S switch fuses offer an economical and reliable solution for the fused short-circuit protection. max 1+1 ( contacts) max 1 ( ind.) max 1+1 ( contacts) 14

9 Fuse monitor Handles FM fuse monitor - facility for immediate tripping under blown fuse conditions No danger for 2-phase motor loading, prevents unsafe neutral voltages perates with all standard fuses; striker-type fuses are not required, thus reducing overall costs No need for external supply voltage Wide voltage ranges, VAC and VAC, +/ - 10 % Safe and reliable EMC tested Fuse Monitor is automatically reset after the blown fuses have been replaced. ne trip contact, one alarm contact, and LEDs (red and green) Full operational ability even with phase unbalance Compact size Snap-on mounting for S switch fuses ncreased reliability with capacitor banks Mechanical blown fuse indicator for striker type fuses External front or side operated P65 handle with an adjustable shaft. Handles available in three colours: black, yellow/red and grey ptional switch-mounted handle (mounting behind the door), also enabling the use of switches padlocked in the FF position together with an external handle Defeatable door interlocking, even with P 65 protection class The door cannot be opened if the switch is padlocked in the FF position The handle can be padlocked in the FF position with three padlocks, thus preventing the door from opening, and closing the circuit during maintenance The handle cannot be padlocked in the FF position if any of the contacts are not totally open 16

10 Side operated Easy to adapt for different applications From 1 pole to 4 pole front and side operated switch fuses. With conversion kits up to 6 and 8 pole switches. Change-over, mechanically interlocked switch combinations can also be built using optional mounting kits Side-to side, plug-in and back termination available n 4 -pole units, the fourth pole is fully rated The fourth pole is available as fusible or non-fusible n S , 3+N -pole version with built-in solid neutral, no extra space needed Flexible mounting Technical features suitable for extreme conditions: Short circuit current up to 100 ka/500 V Utilisation category: AC23 up to 690 VAC Rated impulse withstand voltage: 12 kv Extra thick, 20 µm silver coating on all conductive parts as standard in S This silver coating extends the life of the switch fuse, especially in hazardous environments such as the pulp & paper industry. 18

11 PowerLine Switch Fuses S A Contents: Technical data rdering information Front operated switch fuses S , DN-type Front operated switch fuses S , BS-type Front operated switch fuses S , NFC-type Front operated switch fuses S , Neozed-type Front operated switch fuses S , UL-type Front operated switch fuses S , CSA-type Side operated switch fuses S , DN-type Side operated switch fuses S , BS-type Side operated switch fuses S , NFC-type Side operated switch fuses S , Neozed-type Side operated switch fuses S , UL-type Side operated switch fuses S , CSA-type Accessories Dimension drawings Contact Functions Low Voltage Products Low Voltage Products 21

12 PowerLine Technical Data Switch Fuses S PowerLine Technical Data Switch Fuses S Technical Data According to EC for S Switch-Disconnector-Fuses S Mini S Switch size A Rated insulation voltage Pollution degree 3 V Dielectric strength 50 Hz 1min. kv Rated impulse withstand voltage kv Rated thermal current in ambient 40 C / n open air A / W 16/3,5 20/3,5 25/3,5 32/3,5 35/4 32/7,5 50/7,5 63/7,5 125/12 125/12 160/12 200/14 max. fuse power dissipation 1) n enclosure A / W 16/3,5 20/3,5 25/3,5 32/3,5 35/4 32/7,5 50/7,5 63/7,5 125/12 125/12 160/10, 135/12 180/14, 200/11 n enclosure with solid links A with minimum cable cross section Cu mm 2 2,5 2, Rated operational voltage AC-20 and DC-20 V Rated operational current, AC-21A up to 500 V A V A Rated operational current, AC-22A up to 500 V A V A Rated operational current, AC-23A up to 500 V A V A * 100* 125* 160* 160* Rated operational current / poles in series 48 V A 16 / 2 20 / 2 25 / 2 32 / 2 32 / 2 32 / 2 *) 50 / 2 *) 63 / 2 *) 100 / / / / 2 DC-21A V A 16 / 2 20 / 2 25 / 2 32 / 2 32 / 2 32 / 3 *) 50 / 3 *) 63 / 3 *) 100 / / / / V A 16 / 4 20 / 4 25 / 4 32 / 4 32 / 4 32 / 4 *) 50 / 4 *) 63 / 4 *) 100 / / / / 3 Rated operational current / poles in series 48 V A 16 / 2 20 / 2 25 / 2 32 / 2 32 / 2 32 / 2 *) 50 / 2 *) 63 / 2 *) 100 / / / / 2 DC-22A V A 16 / 2 20 / 2 25 / 2 32 / 2 32 / 2 32 / 3 *) 50 / 3 *) 63 / 3 *) 100 / / / / V A 16 / 4 20 / 4 25 / 4 32 / 4 32 / 4 32 / 4 *) 50 / 4 *) 63 / 4 *) 100 / / / / 3 Rated operational current / poles in series 48 V A 16 / 2 20 / 2 25 / 2 32 / 2 32 / 2 32 / 2 *) 50 / 2 *) 63 / 2 *) 100 / / / / 2 DC-23A V A 16 / 2 20 / 2 25 / 2 32 / 2 32 / 2 32 / 3 *) 50 / 3 *) 63 / 3 *) 100 / / / / V A 16 / 4 20 / 4 25 / 4 32 / 4 32 / 4 32 / 4 *) 50 / 4 *) 63 / 4 *) 100 / / / / 4 Rated operational power, AC-23 2) 230 V kw 4 5, , The kw-ratings are accurate for 400 V kw 7, three-phase 1500 R.P.M. standard 415 V kw 7, , asynchronous motors. 500 V kw V kw Rated breaking capacity in category AC-23 up to 500 V A V A Rated breaking capacity / poles in series up to 220 V A 128 / / / / / / / / / / / / 2 in category DC V A 128 / / / / / / / / / / / / 4 Rated conditional short-circuit current r.m.s. The cut-off currents refer to 80 ka, 415 V ka and corresponding max. allowed cut-off single phase fuse tests. 100 ka, 500 V ka 7,5 7,5 7,5 7,5 7, current, peak value. Fuse selection tables on request. 50 ka, 690 V ka Rated short-time withstand current, 1s. R.M.S. -value ka ,5 2,5 2, Rated capacitor power The capacitor rating of the 400 V kvar switch-fuse is limited by 415 V kvar the fuse link. 690 V kvar Power loss / pole With rated current, without fuse W 0,8 1,3 1,3 2 2,4 1 2, Mechanical endurance Divide by two for operation cycles per Fuse types, EC DN 43620, Neozed DN49522 D D , , , , 00 - NFC x38 14x51-14x51 22x58 22x58 22x BS 88 - A1 - A1, A2, F1 - A2 - A3 A2 - A3 A2 - A3 A2 - A4 3) A2 - A4 3) A2 - A4 3) -size / distance of fuse-link bolts mm - M4 / 44,5 - M4 / 44,5 (A1) - M5 / 73 M5 / 73 M5 / 73 M5/73, M8/94 M5/73, M8/94 M5/73, M8/94 M4 / 73 (A2) - Weight without accessories 3-pole switch fuses kg 0,7 0,7 0,7 0,7 0,7 1,3 1,3 1,3 1,5 1,5 1,5 1,5 4-pole switch fuses kg 0,9 0,9 0,9 0,9 0,9 1,6 1,6 1,6 1,8 1,8 1,8 1,8 Built-in terminal size Cu mm 2 0, , , , , , , , Terminal bolt size Metric thread diameter x length mm M6x20 W:8x25 M6x20 W:8x25 M6x20 W:8x25 M8x25 Terminal tightening torque Counter torque required Nm ,5 3,5 3,5 M6:6-9 M8:15-22 M6:6-9 M8:15-22 M6:6-9 M8:15-22 M8:15-22 Fuse-links bolts tightening torque Nm ,5-3,5 3,5 M5:3,5 M8:5 M5:3,5 M8:5 M5:3,5 M8:5 perating torque Typical for 3-pole switch fuses Nm *= Utilization category B 1) Ambient temperature 60 C: derating 20%. Mounting on "ceiling": derating 10%. Mounting on wall, horizontal fuses: derating 8%. 2) Some fuse links limit these figures further. Starting current characteristics must be considered separately 3) Max. fuse body diam. 32 mm. 22 Low Voltage Products Low Voltage Products 23

13 PowerLine rdering nformation Switch Fuses S S S00799A S 32D_...63D_ S D12 FF FF N N Front operated switch fuses S , DN-type Fuse standards DN 43620, EC SEC Rated impulse withstand voltage (U imp ) 12 kv Rated Rated Fuse Number Type rder number Weight op. current op. power type/ of AC AC-23 size poles < 690V 400/500/690V [A] [kw] [kg] S 32D_ 63D_ Mechanism between the poles ncluding a black handle HB65J6 with -0 and N-FF -indication (P65) and a shaft XP6X161 (length 161 mm, mounting depth H= mm). Protected tunnel terminals, P20, cable size mm 2. Terminal shroud SS63G1 needed for maintaining P20 rating for wire sizes <10mm /22/30 000,00 3 S 32D12 1SCA022456R9710 1, /22/30 000,00 4 2) S 32D22N1 1SCA022456R9890 1, /22/30 000,00 4 3) S 32D22F 1SCA022456R9970 1, /37/60 000,00 3 S 63D12 1SCA022434R7810 1, /37/60 000,00 4 2) S 63D22N1 1SCA022457R0040 1, /37/60 000,00 4 3) S 63D22F 1SCA022456R9460 1,6 S 125D_ 160D_ Mechanism between the poles Terminal width 15 mm ncluding a black handle HB65J6 with -0 and N-FF -indication (P65) and a shaft XP6X161 (length 161 mm, mounting depth H= mm). nclude terminal bolt kit M 6x /80/ ,00 3 S 125D12 1SCA022472R1860 1, /80/ ,00 4 2) S 125D22N1 1SCA022537R8730 1, /80/ ,00 4 3) S 125D22F 1SCA022507R2900 1, /110/ ,00 3 S 160D12 1SCA022472R0030 1, /110/ ,00 4 2) S 160D22N1 1SCA022537R6520 1, /110/ ,00 4 3) S 160D22F 1SCA022506R0560 1,8 Terminal width 20 mm ncluding a black handle HB65J6 with -0 and N-FF -indication (P65) and a shaft XP6X161 (length 161 mm, mounting depth H= mm). nclude terminal bolt kit M 8x /80/ ,00 3 S 125D12W 1SCA022537R2020 1, /80/ ,00 4 2) S 125D22N1W 1SCA022537R8900 1, /80/ ,00 4 3) S 125D22FW 1SCA022537R3260 1,8 S01129A S D03 FF N /110/ ,00 3 S 160D12W 1SCA022510R6650 1, /110/ ,00 4 2) S 160D22N1W 1SCA022537R8570 1, /110/ ,00 4 3) S 160D22FW 1SCA022510R6810 1,8 S 125D_ 160D_ Mechanism at the end of the switch fuse Terminal width 15 mm ncluding a black handle HB65J6 with -0 and N-FF -indication (P65) and a shaft XP6X161 (length 161 mm, mounting depth H= mm). nclude terminal bolt kit M 6x20. 1) /80/ ,00 3 S 125D03 1SCA022469R8780 1, /80/ ,00 4 2) S 125D04N2 1SCA022507R3030 1, /80/ ,00 4 3) S 125D04F 1SCA022469R8860 1, /110/ ,00 3 S 160D03 1SCA022456R8310 1, /110/ ,00 4 2) S 160D04N2 1SCA022507R2650 1, /110/ ,00 4 3) S 160D04F 1SCA022469R8940 1,8 Terminal width 20 mm ncluding a black handle HB65J6 with -0 and N-FF -indication (P65) and a shaft XP6X161 (length 161 mm, mounting depth H= mm). nclude terminal bolt kit M 8x /80/ ,00 3 S 125D03W 1SCA022537R2110 1, /80/ ,00 4 2) S 125D04N2W 1SCA022538R2250 1, /80/ ,00 4 3) S 125D04FW 1SCA022537R3420 1, /110/ ,00 3 S 160D03W 1SCA022510R6310 1, /110/ ,00 4 2) S 160D04N2W 1SCA022510R6490 1, /110/ ,00 4 3) S 160D04FW 1SCA022510R6570 1,8 2) Non-fused neutral 3) Fused neutral 24 Low Voltage Products

14 S01126A PowerLine rdering nformation Switch Fuses S Front operated switch fuses S , BS-type Rated impulse withstand voltage (Uimp) 12 kv Rated Rated Fuse Number Type rder number Weight op. current op. power type/ of poles AC AC-23 size < 690V 415/500/690V [A] [kw] [kg] S Mini Mechanism between the poles ncluding a black handle HB65J5 with -0 and N-FF -indication (P65) and a shaft XP5X150 (length 150 mm, mounting depth H= mm). Protected tunnel terminals, P20, cable size mm 2. Fuse standards BS 88-2, EC SEC S01133A S Mini FF N 20 10/12/15 A1 3 S 20 B12A1 1SCA022533R8510 0, /12/15 A1 4 1) S 20 B22A1N1 1SCA022533R8780 0, /18/25 A1 3 S 32 B12A1 1SCA022530R9500 0, /18/25 A1 4 1) S 32 B22A1N1 1SCA022533R9410 0, /18/25 A2 3 S 32 B12A2 1SCA022533R9830 0, /18/25 A2 4 1) S 32 B22A2N1 1SCA022533R9910 0,9 Fuse standards BS 88-6, EC SEC V 32 15/18/25 F1 3 S 32 B12F1 1SCA022534R2030 0, /18/25 F1 4 1) S 32 B22F1N1 1SCA022534R2200 0,9 S00799A S 32B_...63B_ FF N S 32B_ 63B_ Mechanism between the poles Fuse standards BS 88-2, EC SEC ncluding a black handle HB65J6 with -0 and N-FF -indication (P65) and a shaft XP6X161 (length 161 mm, mounting depth H= mm). Protected tunnel terminals, P20, cable size mm 2. Terminal shroud SS63G1 needed for maintaining P20 rating for wire sizes <10mm /22/30 A2, A3 3 S 32B12 1SCA022470R7610 1, /22/30 A2, A3 4 1) S 32B22N1 1SCA022471R7080 1, /37/60 A2, A3 3 S 63B12 1SCA022434R7990 1, /37/60 A2, A3 4 1) S 63B22N1 1SCA022469R2580 1,6 S 100B_ 200B_ Mechanism between the poles Fuse standards BS 88-2, EC SEC Terminal width 15 mm S B12 FF N ncluding a black handle HB65J6 with -0 and N-FF -indication (P65) and a shaft XP6X161 (length 161 mm, mounting depth H= mm). nclude terminal bolt kit M 6x /60/90 A2, A3 3 S 100B12 1SCA022483R4120 1, /60/90 A2, A3 4 1) S 100B22N1 1SCA022544R6240 1, /80/110 A2, A3, A4 3) 3 S 125B12 1SCA022483R4390 1, /80/110 A2, A3, A4 3) 4 1) S 125B22N1 1SCA022544R6320 1, /110/132 A2, A3, A4 3) 3 S 160B12 1SCA022483R4470 1, /110/132 A2, A3, A4 3) 4 1) S 160B22N1 1SCA022544R6590 1,8 Terminal width 20 mm ncluding a black handle HB65J6 with -0 and N-FF -indication (P65) and a shaft XP6X 161 (length 161 mm, mounting depth H= mm). nclude terminal bolt kit M 8x /60/90 A2, A3 3 S 100B12W 1SCA022546R9610 1, /60/90 A2, A3 4 1) S 100B22N1W 1SCA022552R0580 1, /80/110 A2, A3, A4 3) 3 S 125B12W 1SCA022546R4730 1, /80/110 A2, A3, A4 3) 4 1) S 125B22N1W 1SCA022552R6780 1, /110/132 A2, A3, A4 3) 3 S 160B12W 1SCA022545R9650 1, /110/132 A2, A3, A4 3) 4 1) S 160B22N1W 1SCA022552R0740 1, ) 90/110/132 A2, A3, A4 3) 3 S 200B12W 1SCA022601R4820 1, ) 90/110/132 A2, A3, A4 3) 4 1) S 200B22N1W 1SCA022601R4910 1,8 1) Non-fused neutral 2) Category AC ) Max. fuse diameter 32 mm. Low Voltage Products 25

15 PowerLine rdering nformation Switch Fuses S S01125A S B03 FF N Front operated switch fuses S , BS-type S 100B_ 200B_ Mechanism at the end of the switch fuse Fuse standards BS 88-2, EC SEC Terminal width 15 mm ncluding a black handle HB65J6 with -0 and N-FF -indication (P65) and a shaft XP6X161 (length 161 mm, mounting depth H= mm). nclude terminal bolt kit M 6x20. Rated Rated Fuse Number Type rder number Weight op. current op. power type / of AC AC-23 size poles < 690V 415/500/690V [A] [kw] [kg] /60/90 A2, A3 3 S 100B03 1SCA022456R9030 1, /60/90 A2, A3 4 2) S 100B04N2 1SCA022508R3690 1, /80/110 A2, A3, A4 4) 3 S 125B03 1SCA022456R9110 1, /80/110 A2, A3, A4 4) 4 2) S 125B04N2 1SCA022508R3850 1, /110/132 A2, A3, A4 4) 3 S 160B03 1SCA022536R0870 1, /110/132 A2, A3, A4 4) 4 2) S 160B04N2 1SCA022508R3770 1,8 Terminal width 20 mm ncluding a black handle HB65J6 with -0 and N-FF -indication (P65) and a shaft XP6X (length 161 mm, mounting depth H= mm). nclude terminal bolt kit M 8x /60/90 A2, A3 3 S 100B03W 1SCA022546R9530 1, /60/90 A2, A3 4 2) S 100B04N2W 1SCA022552R0820 1, /80/110 A2, A3, A4 4) 3 S 125B03W 1SCA022546R4220 1, /80/110 A2, A3, A4 4) 4 2) S 125B04N2W 1SCA022552R0910 1, /110/132 A2, A3, A4 4) 3 S 160B03W 1SCA022543R3770 1, /110/132 A2, A3, A4 4) 4 2) S 160B04N2W 1SCA022543R3930 1, ) 90/110/132 A2, A3, A4 4) 4 2) S 200B03W 1SCA022593R9350 1, ) 90/110/132 A2, A3, A4 4) 4 2) S 200B04N2W 1SCA022593R9430 1,8 2) Non-fused neutral 3) Category AC ) Max. fuse diameter 32 mm. 26 Low Voltage Products

16 S01126A PowerLine rdering nformation Switch Fuses S Front operated switch fuses S , NFC-type Fuse standards NFC 63210, NFC 63211, EC SEC, rated impulse withstand voltage (Uimp) 12 kv S Mini Mechanism between the poles ncluding a black handle HB65J5 with -0 and N-FF -indication (P65) and a shaft XP5X150 (length 150 mm, mounting depth H= mm). Protected tunnel terminals, P20, cable size mm 2. S01133A S Mini FF N Rated Rated Fuse Number Type rder number Weight op. current op. power type / of poles AC AC-23 size < 690V 400/500/690V [A] [kw] [kg] 25 11/14/22 10x38 3 S 25 F1210 1SCA022534R0500 0, /14/22 10x38 4 1) S 25 F2210N1 1SCA022534R0840 0, /14/22 10x38 4 2) S 25 F2210F 1SCA022534R0170 0, /18/25 14x51 3 S 32 F1214 1SCA022534R1570 0, /18/25 14x51 4 1) S 32 F2214N1 1SCA022534R1650 0, /18/25 14x51 4 2) S 32 F2214F 1SCA022534R1310 0,9 S00799A S01125A S 50F_...63 S 100F_ 125F_ S 100F_...125F FF FF N FF N N S 50F_ 63F_ Mechanism between the poles ncluding a black handle HB65J6 with -0 and N-FF -indication (P65) and a shaft XP6X161 (length 161 mm, mounting depth H= mm). Protected tunnel terminals, P20, cable size mm 2. Terminal shroud SS63G1 needed for maintaining P20 rating for wire sizes <10mm /33/45 14x51 3 S 50F12 1SCA022434R8020 1, /33/45 14x51 4 1) S 50F22N1 1SCA022471R0820 1, /33/45 14x51 4 2) S 50F22F 1SCA022472R0110 1, /37/60 22x58 3 S 63F12 1SCA022434R8110 1, /37/60 22x58 4 1) S 63F22N1 1SCA022471R0740 1, /37/60 22x58 4 2) S 63F22F 1SCA022471R9960 1,6 S 100F_ 125F_ Mechanism between the poles Terminal width 15 mm ncluding a black handle HB65J6 with -0 and N-FF -indication (P65) and a shaft XP6X161 (length 161 mm, mounting depth H= mm). nclude terminal bolt kit M 6x /60/90 22x58 3 S 100F12 1SCA022508R2450 1, /60/90 22x58 4 1) S 100F22N1 1SCA022544R6670 1, /60/90 22x58 4 2) S 100F22F 1SCA022508R2610 1, /80/110 22x58 3 S 125F12 1SCA022507R7290 1, /80/110 22x58 4 1) S 125F22N1 1SCA022544R6750 1, /80/110 22x58 4 2) S 125F22F 1SCA022507R7370 1,8 Terminal width 20 mm ncluding a black handle HB65J6 with -0 and N-FF -indication (P65) and a shaft XP6X161 (length 161 mm, mounting depth H= mm). nclude terminal bolt kit M 8x /60/90 22x58 3 S 100F12W 1SCA022547R7550 1, /60/90 22x58 4 1) S 100F22N1W1SCA022552R2010 1, /60/90 22x58 4 2) S 100F22FW 1SCA022552R2280 1, /80/110 22x58 3 S 125F12W 1SCA022547R0620 1, /80/110 22x58 4 1) S 125F22N1W1SCA022552R2100 1, /80/110 22x58 4 2) S 125F22FW 1SCA022552R2360 1,8 S 100F_ 125F_ Mechanism at the end of the switch fuse Terminal width 15 mm ncluding a black handle HB65J6 with -0 and N-FF -indication (P65) and a shaft XP6X161 (length 161 mm, mounting depth H= mm). nclude terminal bolt kit M 6x /60/90 22x58 3 S 100F03 1SCA022502R6460 1, /60/90 22x58 4 1) S 100F04N2 1SCA022508R4580 1, /60/90 22x58 4 2) S 100F04F 1SCA022502R6540 1, /80/110 22x58 3 S 125F03 1SCA022502R7010 1, /80/110 22x58 4 1) S 125F04N2 1SCA022505R1570 1, /80/110 22x58 4 2) S 125F04F 1SCA022503R0810 1,8 Terminal width 20 mm ncluding a black handle HB65J6 with -0 and N-FF -indication (P65) and a shaft XP6X161 (length 161 mm, mounting depth H= mm). nclude terminal bolt kit M 8x /60/90 22x58 3 S 100F03W 1SCA022547R7390 1, /60/90 22x58 4 1) S 100F04N2W1SCA022552R2440 1, /60/90 22x58 4 2) S 100F04FW 1SCA022552R2610 1, /80/110 22x58 3 S 125F03W 1SCA022547R0380 1, /80/110 22x58 4 1) S 125F04N2W1SCA022552R2520 1, /80/110 22x58 4 2) S 125F04FW 1SCA022552R2790 1,8 1) Non-fused neutral 2) Fused neutral Low Voltage Products 27

17 S01126A PowerLine rdering nformation Switch Fuses S Front operated switch fuses S , Neozed-type S01133A FF S Mini, Neozed-type N Fuse standards, EC Sec., rated impulse withstand voltage (Uimp) 12 kv Rated Rated Fuse Number Type rder number Weight op. current op. power type/ of AC AC-23 size poles < 690V 400/500/690V [A] [kw] [kg] S Mini Mechanism between the poles ncluding a black handle HB65J5 with -0 and N-FF -indication (P65) and a shaft XP5X150 (length 150 mm, mounting depth H= mm). Protected tunnel terminals, P20, cable size mm /9/11 D1 1) 3 S 16 D1201 1SCA022557R6610 0, /9/11 D1 1) 4 2) S 16 D2201N1 1SCA022557R6700 0, /9/11 D1 1) 4 3) S 16 D2201F 1SCA022557R6880 0, /18/25 D2 3 S 35 D1202 1SCA022557R6960 0, /18/25 D2 4 2) S 35 D2202N1 1SCA022557R7000 0, /18/25 D2 4 3) S 35 D2202F 1SCA022557R7180 0,9 Front operated switch fuses S , UL-type Fuse standards UL 198C, EC Sec. V Rated impulse withstand voltage (Uimp) 12 kv Ampere Horse power Fuse Number Type rder number Weight rating ratings type/ of 3 phase size poles 208/480/600V [A] [HP] [kg] S01133A S Mini, UL-type FF N S Mini Mechanism between the poles ncluding a black handle HB65J5 with -0 and N-FF -indication (P65) and a shaft XP5X150 (length 150 mm, mounting depth H= mm). Protected tunnel terminals, P20, cable size mm 2, (AWG 18-8). 30 7,5 / 15 / 20 CC, 30A 3 S30ACC12P 1SCA022533R7460 0,7 30 7,5 / 15 / 20 CC, 30A 4 3) S30ACC22FP 1SCA022533R7030 0,9 30 7,5 / 15 / 20 J, 30A 3 S30AJ12P 1SCA022533R8010 0,7 30 7,5 / 15 / 20 J, 30A 4 3) S30AJ22FP 1SCA022533R7710 0,9 S00799A S 60J_ FF N S 60J_ Mechanism between the poles ncluding a black handle HB65J6 with -0 and N-FF -indication (P65) and a shaft XP6X161 (length 161 mm, mounting depth H= mm). Protected tunnel terminals, P20, cable size mm 2. Terminal shroud SS63G1 needed for maintaining P20 rating for wire sizes <10mm 2, (AWG 14-4) / 30 / 50 J, 60A 3 S60J12P 1SCA022434R8290 1, / 30 / 50 J, 60A 4 2) S60J22N1P 1SCA022471R1210 1, / 30 / 50 J, 60A 4 3) S60J22FP 1SCA022472R0460 1,6 FF N S 100J_ Mechanism between the poles Terminal width 15 mm ncluding a black handle HB65J6 with -0 and N-FF -indication (P65) and a shaft XP6X161 (length 161 mm, mounting depth H= mm). nclude terminal bolt kit M 6x / 60 / 75 J, 100A 3 S100J12P 1SCA022483R4550 1, / 60 / 75 J, 100A 4 2) S100J22N1P 1SCA022544R6830 1, / 60 / 75 J, 100A 4 3) S100J22FP 1SCA022508R2960 1,8 Terminal width 20 mm ncluding a black handle HB65J6 with -0 and N-FF -indication (P65) and a shaft XP6X161 (length 161 mm, mounting depth H= mm). nclude terminal bolt kit M 8x / 60 / 75 J, 100A 3 S100J12WP 1SCA022547R5000 1, / 60 / 75 J, 100A 4 2) S100J22N1WP 1SCA022552R3090 1, / 60/ 75 J, 100A 4 3) S100J22FWP 1SCA022552R3170 1,8 S 100J_ Mechanism at the end of the switch fuse Terminal width 15 mm ncluding a black handle HB65J6 with -0 and N-FF -indication (P65) and a shaft XP6X161 (length 161 mm, mounting depth H= mm). nclude terminal bolt kit M 6x / 60 / 75 J, 100A 3 S100J03P 1SCA022456R8810 1, / 60 / 75 J, 100A 4 2) S100J04N2P 1SCA022544R7050 1, / 60/ 75 J, 100A 4 3) S100J04FP 1SCA022508R2700 1,8 Terminal width 20 mm ncluding a black handle HB65J6 with -0 and N-FF -indication (P65) and a shaft XP6X161 (length 161 mm, mounting depth H= mm). nclude terminal bolt kit M 8x / 60 / 75 J, 100A 3 S100J03WP 1SCA022547R4960 1, / 60 / 75 J, 100A 4 2) S100J04N2WP 1SCA022552R3250 1, / 60/ 75 J, 100A 4 3) S100J04FWP 1SCA022552R3330 1,8 S 100J12 S01125A FF N S 100J03 1) Please, use D2 adapter rings. 2) Non-fused neutral. 3) Fused neutral 28 Low Voltage Products

18 S01126A PowerLine rdering nformation Switch Fuses S Front operated switch fuses S , CSA-type Fuse standards CSA C22.2 No 106, EC Sec. (Dimensions) Rated impulse withstand voltage (Uimp) 12 kv Ampere Horse power Fuse Number Type rder number Weight rating ratings type/ of 3 phase size poles 208/480/600V [A] [HP] [kg] S00799A S 30C_...60C_ FF N S 30C_...60C_ Mechanism between the poles ncluding a black handle HB65J6 with -0 and N-FF -indication (P65) and a shaft XP6X161 (length 161 mm, mounting depth H= mm). Protected tunnel terminals, P20, cable size mm 2. Terminal shroud SS63G1 needed for maintaining P20 rating for wire sizes <10mm 2, (AWG 14-4). 30 7,5 / 15 / 20 C, 30A 3 S30C12P 1SCA022471R9110 1,3 30 7,5 / 15 / 20 C, 30A 4 1) S30C22N1P 1SCA022471R9370 1,6 30 7,5 / 15 / 20 C, 30A 4 2) S30C22FP 1SCA022472R0380 1, / 30 / 50 C, 60A 3 S60C12P 1SCA022434R8370 1, / 30 / 50 C, 60A 4 1) S60C22N1P 1SCA022471R1470 1, / 30 / 50 C, 60A 4 2) S60C22FP 1SCA022472R0200 1,6 FF N S 100C_ Mechanism between the poles Terminal width 15 mm ncluding a black handle HB65J6 with -0 and N-FF -indication (P65) and a shaft XP6X161 (length 161 mm, mounting depth H= mm). nclude terminal bolt kit M 6x / 60 / 75 C, 100A 3 S100C12P 1SCA022483R4630 1, / 60 / 75 C, 100A 4 1) S100C22N1P 1SCA022544R7130 1, / 60/ 75 C, 100A 4 2) S100C22FP 1SCA022507R6990 1,8 S 100C12 Terminal width 20 mm ncluding a black handle HB65J6 with -0 and N-FF -indication (P65) and a shaft XP6X161 (length 161 mm, mounting depth H= mm). nclude terminal bolt kit M 8x / 60 / 75 C, 100A 3 S100C12WP 1SCA022548R0260 1, / 60 / 75 C, 100A 4 1) S100C22N1WP 1SCA022552R3410 1, / 60/ 75 C, 100A 4 2) S100C22FWP 1SCA022552R3500 1,8 S01125A FF N S 100C_ Mechanism at the end of the switch fuse Terminal width 15 mm ncluding a black handle HB65J6 with -0 and N-FF -indication (P65) and a shaft XP6X161 (length 161 mm, mounting depth H= mm). nclude terminal bolt kit M 6x / 60 / 75 C, 100A 3 S100C03P 1SCA022456R8730 1, / 60 / 75 C, 100A 4 1) S100C04N2P 1SCA022508R3930 1, / 60/ 75 C, 100A 4 2) S100C04FP 1SCA022507R6810 1,8 S100C03 Terminal width 20 mm ncluding a black handle HB65J6 with -0 and N-FF -indication (P65) and a shaft XP6X161 (length 161 mm, mounting depth H= mm). nclude terminal bolt kit M 8x / 60 / 75 C, 100A 3 S100C03WP 1SCA022548R0000 1, / 60 / 75 C, 100A 4 1) S100C04N2WP 1SCA022552R3760 1, / 60/ 75 C, 100A 4 2) S100C04FWP 1SCA022552R3840 1,8 1) Non-fused neutral. 2) Fused neutral. Low Voltage Products 29

19 S01132A PowerLine rdering nformation Switch Fuses S S00958A S 32DS_...63DS_ S DS30 Side operated switch fuses S , DN-type Fuse standards DN 43620, EC Sec. Rated impulse withstand voltage (Uimp) 12 kv ncluding a black handle with -0 and N-FF -indication (P65) and a shaft S 32DS_ 63DS_ Mounting depths measured from the left side of the switch, 3-pole:H= mm and 4-pole:H= mm. Protected tunnel terminals, P20, cable size mm 2. Terminal shroud SS63G1 needed for maintaining P20 rating for wire sizes <10mm 2. Rated Rated Fuse Number Type rder number Weight op. current op. power type / of AC AC-23 size poles < 690V 400/500/690V [A] [kw] [kg] 32 15/22/30 000,00 3 S 32DS30 1SCA022471R3090 1, /22/30 000,00 4 1) S 32DS40N1 1SCA022471R6600 1, /22/30 000,00 4 2) S 32DS40F 1SCA022472R0620 1, /37/60 000,00 3 S 63DS30 1SCA022467R6970 1, /37/60 000,00 4 1) S 63DS40N1 1SCA022471R5890 1, /37/60 000,00 4 2) S 63DS40F 1SCA022472R0540 1,6 S 125DS_ 160DS_ Terminal width 15 mm Mounting depths measured from the left side of the switch, 3-pole:H= mm and 4-pole:H= mm. nclude terminal bolt kit M 6x /80/ ,00 3 S 125DS30 1SCA022502R6890 1, /80/ ,00 4 1) S 125DS40N1 1SCA022543R2370 1, /80/ ,00 4 3) S 125DS40N2 1SCA022544R7210 1, /80/ ,00 4 2) S 125DS40F 1SCA022502R6970 1, /110/ ,00 3 S 160DS30 1SCA022502R6970 1, /110/ ,00 4 1) S 160DS40N1 1SCA022537R6280 1, /110/ ,00 4 3) S 160DS40N2 1SCA022544R7300 1, /110/ ,00 4 2) S 160DS40F 1SCA022502R7430 1,8 Terminal width 20 mm Mounting depths measured from the left side of the switch, 3-pole:H= mm and 4-pole:H= mm. nclude terminal bolt kit M 8x /80/ ,00 3 S 125DS30W 1SCA022538R3060 1, /80/ ,00 4 1) S 125DS40N1W 1SCA022543R2450 1, /80/ ,00 4 3) S 125DS40N2W 1SCA022552R3920 1, /80/ ,00 4 2) S 125DS40FW 1SCA022543R2290 1, /110/ ,00 3 S 160DS30W 1SCA022538R2410 1, /110/ ,00 4 1) S 160DS40N1W 1SCA022538R6590 1, /110/ ,00 4 3) S 160DS40N2W 1SCA022552R4060 1, /110/ ,00 4 2) S 160DS40FW 1SCA022538R6080 1,8 1) Non-fused neutral, left. 2) Fused neutral. 3) Non-fused neutral, right. 30 Low Voltage Products

20 S01132A PowerLine rdering nformation Switch Fuses S S01146A S Mini S00958A S 32BS_...63BS_ S BS30 FF N FF TEST N Side operated switch fuses S , BS-type Rated impulse withstand voltage (Uimp) 12 kv ncluding a black handle with -0 and N-FF -indication (P65) and a shaft. Rated Rated Fuse Number Type rder number Weight op. current op. power type / of AC AC-23 size poles < 690V 415/500/690V [A] [kw] [kg] S Mini Mounting depths measured from the left side of the switch, 3-pole:H= mm and 4-pole:H= mm. Protected tunnel terminals, P20, cable size mm 2. Fuse standards BS 88-2, EC SEC 20 10/12/15 A1 3 S 20 BS30A1 1SCA022533R8940 0, /12/15 A1 4 1) S 20 BS40A1N1 1SCA022533R9080 0, /18/25 A1 3 S 32 BS30A1 1SCA022533R9670 0, /18/25 A1 4 1) S 32 BS40A1N1 1SCA022533R9750 0, /10/25 A2 3 S 32 BS30A2 1SCA022534R0090 0, /25 A2 4 1) S 32 BS40A2N1 1SCA022556R8430 0,9 Fuse standards BS 88-6, EC SEC V 32 15/18/25 F1 3 S 32 BS30F1 1SCA022534R2380 0, /18/25 F1 4 1) S 32 BS40F1N1 1SCA022534R2460 0,9 S 32BS_ 63BS_ Fuse standards BS 88-2, EC SEC Mounting depths measured from the left side of the switch, 3-pole:H= mm and 4-pole:H= mm. Protected tunnel terminals, P20, cable size mm 2. Terminal shroud SS63G1 needed for maintaining P20 rating for wire sizes <10mm /22/30 A2, A3 3 S 32BS30 1SCA022471R6940 1, /22/30 A2, A3 4 1) S 32BS40N1 1SCA022471R7410 1, /37/60 A2, A3 3 S 63BS30 1SCA022471R0150 1, /37/60 A2, A3 4 1) S 63BS40N1 1SCA022471R7320 1,6 S 100BS_ 160BS_ Fuse standards BS 88-2, EC SEC Terminal width 15 mm Mounting depths measured from the left side of the switch, 3-pole:H= mm and 4-pole:H= mm. nclude terminal bolt kit M 6x /60/90 A2, A3 3 S 100BS30 1SCA022508R3000 1, /60/90 A2, A3 4 1) S 100BS40N1 1SCA022544R7480 1, /60/90 A2, A3 4 2) S 100BS40N2 1SCA022544R7560 1, /80/110 A2, A3, A4 3) 3 S 125BS30 1SCA022508R3340 1, /80/110 A2, A3, A4 3) 4 1) S 125BS40N1 1SCA022544R7720 1, /80/110 A2, A3, A4 3) 4 2) S 125BS40N2 1SCA022544R7810 1, /110/132 A2, A3, A4 3) 3 S 160BS30 1SCA022508R3260 1, /110/132 A2, A3, A4 3) 4 1) S 160BS40N1 1SCA022544R8020 1, /110/132 A2, A3, A4 3) 4 2) S 160BS40N2 1SCA022544R8110 1,8 Terminal width 20 mm Mounting depths measured from the left side of the switch, 3-pole:H= mm and 4-pole:H= mm. nclude terminal bolt kit M 8x /60/90 A2, A3 3 S 100BS30W 1SCA022548R3010 1, /60/90 A2, A3 4 1) S 100BS40N1W 1SCA022552R4140 1, /60/90 A2, A3 4 2) S 100BS40N2W 1SCA022552R4490 1, /80/110 A2, A3, A4 3) 3 S 125BS30W 1SCA022548R1310 1, /80/110 A2, A3, A4 3) 4 1) S 125BS40N1W 1SCA022552R4220 1, /80/110 A2, A3, A4 3) 4 2) S 125BS40N2W 1SCA022552R4570 1, /110/132 A2, A3, A4 3) 3 S 160BS30W 1SCA022548R1230 1, /110/132 A2, A3, A4 3) 4 1) S 160BS40N1W 1SCA022552R4310 1, /110/132 A2, A3, A4 3) 4 2) S 160BS40N2W 1SCA022552R4650 1,8 1) Non-fused neutral,left 2) Non-fused neutral, right. 3) Max. diameter 32 mm. Low Voltage Products 31

21 S01132A PowerLine rdering nformation Switch Fuses S S01146A S Mini S00958A FF N FF TEST S 50FS_...63FS_ S FS30 N Side operated switch fuses S , NFC-type Fuse standards NFC 63210, NFC 63211, EC SEC Rated impulse withstand voltage (Uimp) 12 kv ncluding a black handle with -0 and N-FF -indication (P65) and a shaft. Rated Rated Fuse Number Type rder number Weight op. current op. power type / of AC AC-23 size poles < 690V 400/500/690V [A] [kw] [kg] S Mini Mounting depths measured from the left side of the switch, 3-pole:H= mm and 4pole:H= mm. Protected tunnel terminals, P20, cable size mm /14/22 10x38 3 S 25 FS3010 1SCA022534R1060 0, /14/22 10x38 4 1) S 25 FS4010N1 1SCA022534R1220 0, /14/22 10x38 4 2) S 25 FS4010F 1SCA022534R0330 0, /18/25 14x51 3 S 32 FS3014 1SCA022534R1810 0, /18/25 14x51 4 1) S 32 FS4014N1 1SCA022534R1900 0, /18/25 14x51 4 2) S 32 FS4014F 1SCA022534R1490 0,9 S 50FS_ 63FS_ Mounting depths measured from the left side of the switch, 3-pole:H= mm and 4-pole:H= mm. Protected tunnel terminals, P20, cable size mm 2. Terminal shroud SS63G1 needed for maintaining P20 rating for wire sizes <10mm /33/45 14x51 3 S 50FS30 1SCA022471R1040 1, /33/45 14x51 4 1) S 50FS40N1 1SCA022471R9610 1, /33/45 14x51 4 2) S 50FS40F 1SCA022472R1190 1, /37/60 22x58 3 S 63FS30 1SCA022471R0910 1, /37/60 22x58 4 1) S 63FS40N1 1SCA022471R9530 1, /37/60 22x58 4 2) S 63FS40F 1SCA022472R0970 1,6 S 100FS_ 125FS_ Terminal width 15 mm Mounting depths measured from the left side of the switch, 3-pole:H= mm and 4-pole:H= mm. nclude terminal bolt kit M 6x /60/90 22x58 3 S 100FS30 1SCA022502R6620 1, /60/90 22x58 4 1) S 100FS40N1 1SCA022544R8370 1, /60/90 22x58 4 3) S 100FS40N2 1SCA022544R8450 1, /60/90 22x58 4 2) S 100FS40F 1SCA022502R6710 1, /80/110 22x58 3 S 125FS30 1SCA022502R7270 1, /80/110 22x58 4 1) S 125FS40N1 1SCA022544R8530 1, /80/110 22x58 4 3) S 125FS40N2 1SCA022544R8610 1, /80/110 22x58 4 2) S 125FS40F 1SCA022502R7350 1,8 Terminal width 20 mm Mounting depths measured from the left side of the switch, 3-pole:H= mm and 4-pole:H= mm. nclude terminal bolt kit M 8x /60/90 22x58 3 S 100FS30W 1SCA022547R8010 1, /60/90 22x58 4 1) S 100FS40N1W 1SCA022552R5030 1, /60/90 22x58 4 3) S 100FS40N2W 1SCA022552R5200 1, /60/90 22x58 4 2) S 100FS40FW 1SCA022552R5540 1, /80/110 22x58 3 S 125FS30W 1SCA022547R2080 1, /80/110 22x58 4 1) S 125FS40N1W 1SCA022552R5110 1, /80/110 22x58 4 3) S 125FS40N2W 1SCA022552R5380 1, /80/110 22x58 4 2) S 125FS40FW 1SCA022552R5460 1,8 1) Non-fused neutral, left. 2) Fused neutral. 3) Non-fused neutral, right. 32 Low Voltage Products

22 S01132A PowerLine rdering nformation Switch Fuses S Side operated switch fuses S , Neozed-type Fuse standards, EC SEC Rated impulse withstand voltage (Uimp) 12 kv ncluding a black handle with -0 and N-FF -indication (P65) and a shaft. Rated Rated Fuse Number Type rder number Weight op. current op. power type / of AC AC-23 size poles < 690V 400/500/690V [A] [kw] [kg] S01146A S Mini FF N FF TEST N S Mini Mounting depths measured from the left side of the switch, 3-pole:H= mm and 4pole:H= mm. Protected tunnel terminals, P20, cable size mm /9/11 D 1 1) 3 S 16 DS3001 1SCA022557R6020 0, /9/11 D 1 1) 4 2) S 16 DS4001N1 1SCA022557R6110 0, /9/11 D 1 1) 4 3) S 16 DS4001F 1SCA022557R6290 0, /18/25 D 2 3 S 35 DS3002 1SCA022557R6370 0, /18/25 D 2 4 2) S 35 DS4002N1 1SCA022557R6450 0, /18/25 D 2 4 3) S 35 DS4002F 1SCA022557R6530 0,9 Side operated switch fuses S , UL-type Fuse standards UL 198C, EC SEC V S01146A S Mini S00958A S 60JS_ S 100JS30P_ FF N FF TEST N Rated impulse withstand voltage (Uimp) 12 kv. ncluding black handle with -0 and N-FF -indication (P65) and a shaft. Ampere Horse power Fuse Number Type rder number Weight rating ratings type/ of 3 phase size poles 208/480/600V [A] [HP] [kg] S Mini Mounting depths measured from the left side of the switch, 3-pole:H= mm and 4-pole:H= mm. Protected tunnel terminals, P20, cable size mm 2, (AWG 18-8). 30 7,5/15/20 CC, 30A 3 S30ACCS30P 1SCA022533R7110 0,7 30 7,5/15/20 J, 30A 3 S30AJS30P 1SCA022533R7970 0,7 S 60JS_ Mounting depths measured from the left side of the switch, 3-pole:H= mm and 4-pole:H= mm. Protected tunnel terminals, P20, cable size mm 2. Terminal shroud SS63G1 needed for maintaining P20 rating for wire sizes <10mm 2, (AWG 14-4) /30/50 J, 60A 3 S60JS30P 1SCA022471R0580 1, /30/50 J, 60A 4 2) S60JS40N1P 1SCA022471R9880 1, /30/50 J, 60A 4 3) S60JS40FP 1SCA022472R1430 1,6 S 100JS_ Terminal width 15 mm Mounting depths measured from the left side of the switch, 3-pole:H= mm and 4-pole:H= mm /60/75 J, 100A 3 S100JS30P 1SCA022508R3510 1, /60/75 J, 100A 4 2) S100JS40N1P 1SCA022544R8700 1, /60/75 J, 100A 4 4) S 100JS40N2P 1SCA022544R8880 1, /60/75 J, 100A 4 3) S100JS40FP 1SCA022544R8960 1,8 Terminal width 20 mm Mounting depths measured from the left side of the switch, 3-pole:H= mm and 4-pole:H= mm. nclude terminal bolt kit M 8x /60/75 J, 100A 3 S100JS30WP 1SCA022547R5510 1, /60/75 J, 100A 4 2) S100JS40N1WP 1SCA022552R5620 1, /60/75 J, 100A 4 4) S 100JS40N2WP 1SCA022552R5710 1, /60/75 J, 100A 4 3) S100JS40FWP 1SCA022552R5890 1,8 1) Please, use Neozed D2 adaper ring. 2) Non-fused neutral, left. 3) Fused neutral. 4) Non-fused neutral, right. Low Voltage Products 33

23 PowerLine rdering nformation Switch Fuses S Side operated switch fuses S , CSA-type Fuse standards CSA CS40.2 No 106, EC SEC (Dim.) Rated impulse withstand voltage (Uimp) 12 kv ncluding black handle with -0 and N-FF -indication (P65) and a shaft. Ampere Horse power Fuse Number Type rder number Weight rating ratings type/ of 3 phase size poles 208/480/600V [A] [HP] [kg] S00958A S 30CS_...60CS_ S 30CS_ 60CS_ Mounting depths measured from the left side of the switch, 3-pole:H= mm and 4-pole:H= mm. Protected tunnel terminals, P20, cable size mm 2. Terminal shroud SS63G1 needed for maintaining P20 rating for wire sizes <10mm 2, (AWG 14-4). 30 7,5/15/20 C, 30A 3 S30CS30P 1SCA022471R9290 1,3 30 7,5/15/20 C, 30A 4 1) S30CS40N1P 1SCA022471R9700 1,6 30 7,5/15/20 C, 30A 4 2) S30CS40FP 1SCA022472R1350 1, /30/50 C, 60A 3 S60CS30P 1SCA022471R0310 1, /30/50 C, 60A 4 1) S60CS40N1P 1SCA022471R9450 1, /30/50 C, 60A 4 2) S60CS40FP 1SCA022472R1270 1,6 S01127A S 100CS_ Terminal width 15 mm Mounting depths measured from the left side of the switch, 3-pole:H= mm and 4-pole:H= mm. nclude terminal bolt kit M 6x /60/75 C, 100A 3 S100CS30P 1SCA022508R3420 1, /60/75 C, 100A 4 1) S100CS40N1P 1SCA022544R9000 1, /60/75 C, 100A 4 3) S 100CS40N2P 1SCA022544R9180 1, /60/75 C, 100A 4 2) S100CS40FP 1SCA022544R9260 1,8 S100CS30 Terminal width 20 mm Mounting depths measured from the left side of the switch, 3-pole:H= mm and 4-pole:H= mm. nclude terminal bolt kit M 8x /60/75 C, 100A 3 S100CS30WP 1SCA022548R1150 1, /60/75 C, 100A 4 1) S100CS40N1WP 1SCA022552R5970 1, /60/75 C, 100A 4 3) S 100CS40N2WP 1SCA022552R6010 1, /60/75 C, 100A 4 2) S100CS40FWP 1SCA022552R6600 1,8 1) Non-fused neutral, left. 3) Non-fused neutral, right. 2) Fused neutral. 34 Low Voltage Products

24 Switch Fuses PowerLine, S A Accessories Contents: Accessories ptional plastic handles Extended shafts Fourth poles Auxiliary contacts, P Terminal shrouds Neutral and solid links Connecting accessories Blown fuse indicators Fuse monitor Fuse replacement handles Conversion kits for the combination switches Low Voltage Products 35

25 PowerLine rdering nformation Switch Fuses S Accessories S00836A FF ptional plastic handles Handles for front operated switches P 65 S00601A FF N Padlockable with three padlocks in FF-position, door interlock in N-position. (defeatable to allow authorized personnel access for inspection). Door drilling Ø 53 mm.the shaft has to be ordered separately. Screw fixing from back side of handle, no screws on front, ensures double protection. Colour Recomm. order Type rder number Weight quantity / multiples of kg N N For S Mini Black and red-yellow: -/N-FF, grey: -. Handle length 65 mm, suitable for shaft diameter 5 mm Black 100 HB 65J5 1) 1SCA022380R Yellow-red 100 HY 65J5 1SCA022380R Grey 100 HG 65J5 1SCA022380R S00659A S00778A S01200A FF H_65J_ S00435A 132 HB 5 HB 4 Black and red-yellow: /-/N-FF, grey: /-. Handle length 65 mm, suitable for shaft diameter 5 mm Black 100 HB 65J5T 1SCA022382R Yellow-red 100 HY 65J5T 1SCA022429R Grey 100 HG 65J5T 1SCA022556R For S Black and red-yellow: -/N-FF, grey: -. Handle length 65 mm, suitable for shaft diameter 6 mm Black 100 HB 65J6 1) 1SCA022380R Red-Yellow 100 HY 65J6 1SCA022380R Grey 100 HG 65J6 1SCA022380R Black and red-yellow: /-/N-FF, grey: /-. Handle length 65 mm, suitable for shaft diameter 6 mm Black 100 HB 65J6T 1SCA022399R Red-Yellow 100 HY 65J6T 1SCA022456R Grey 100 HG 65J6T 1SCA022456R Handles for side operated switches P 65 Padlockable with three padlocks in FF-position, door interlock in N-position. f the handle is mounted on the front of the door, a standard handle can be used as well. For S Mini Black and red-yellow: /-/N-FF, grey: /-. Handle length 65 mm, suitable for shaft diameter 5 mm Black 100 HB 65J5TE00S 1SCA022382R Yellow-red 100 HY 65J5TE00S 1SCA022556R Grey 100 HG 65J5TE00S 1SCA022556R For S Black and red-yellow: /-/N-FF, grey: /-. Handle length 65 mm, suitable for shaft diameter 6 mm Black 100 HB 65J6TE001S 1SCA022532R Red-Yellow 100 HY 65J6TE001S 1SCA022532R Grey 100 HG 65J6TE001S 1SCA022532R Direct mounted handle Panel board handle, includes a shaft, which can be padlocked in 0-position when the door is open. The handle can be also used with a standard shaft as padlocking device. For S Mini ndication -/N-FF/TEST, handle padlockable with 2 padlocks in 0 and -positions when door opened. Max. bail dia 8 mm. Black 100 HB 5 1SCA022192R For S Padlockable with three padlocks in 0-position when door opened. Max. bail dia 6 mm. Black 100 HB 4 1SCA022439R ) ncluded as standard 36 Low Voltage Products

26 PowerLine rdering nformation Switch Fuses S Accessories Extended shafts For S Mini H H S00686A S00969A S00050B S00050A XP5X_ XP6X_ S00669A XP_X_-45 Shaft Front Side Recomm. Type rder number Weight length operated operated 2) order (mm) H / mm H / mm quantity kg XP5X150 3) 1SCA022376R XP5X170 1SCA022376R XP5X265 1SCA022376R XP5X400 1SCA022376R XP5X ) 1SCA022474R XP5X ) 1SCA022474R XP5X ) 1SCA022474R XP5X ) 1SCA022474R For S Shaft diameter 6 mm Shaft Front Side Recomm. Type rder number Weight length operated operated 4) order (mm) H / mm H / mm quantity kg XP6X150 1SCA022295R XP6X161 5) 1SCA022067R XP6X210 1SCA022295R XP6X290 1SCA022042R XP6X360 1SCA022042R XP6X430 1SCA022056R XP6X ) 1SCA022294R XP6X ) 1SCA022304R XP6X ) 1SCA022341R For S , XP6X150 1SCA022295R , XP6X161 5) 1SCA022067R XP6X210 1SCA022295R XP6X290 1SCA022042R XP6X360 1SCA022042R XP6X430 1SCA022056R XP6X ) 1SCA022294R XP6X ) 1SCA022304R XP6X ) 1SCA022341R4640 1) 0.10 Fourth Poles for S Snap-on mounting to the left side of the switch. SP4_ Suitable for Type rder number Weight 3-pole switches kg Fusible 4. poles S32D_, S63D_ SP4D 1SCA022472R S32B_, S63B_ SP4B 1SCA022472R S50F_ SP4F14 1SCA022472R S63F_ SP4F22 1SCA022472R S30C_, S60C_ SP4C 1SCA022472R S60J_ SP4J 1SCA022472R Switched 4. poles S30_...S63_ SP4N 1SCA022472R ) The shaft position is rotated 45 degrees. 2) 4-pole: add 36 mm. 3) ncluded as standard. 4) 4-pole: S : add 45 mm, S : add 35 mm. 5) ncluded as standard Low Voltage Products 37

27 PowerLine rdering nformation Switch Fuses S Accessories S01161A A 4B_max 1+1 A1G_, A3G_+SZ4 S Mini max 1+1 S max 1+1 max 1 0S S00261A A_G SK ESAZX 169 max 6 Auxiliary contacts, P20 Auxiliary contacts for S Mini Description Type rder number Weight Auxiliary/test contacts, mounting to the switch mechanism. Max. two change over contacts. The type includes one change over contact. Technical data: U e = 24V,/ e (DC12) =6A; U e = 250V/ e ( AC 15) = 3A, e ( DC12) =0.1A; U e = 440V/ e ( AC 15) = 2A Handle Main Aux. / position contacts contacts N.. 0 open open closed closed open closed _3 _1 1 N.. N NC A4B10 1SCA022276R9050 0,03 1 N.C. _4 _2 A4B01 1SCA022276R9210 0,03 Mounting on side of the switch with aux.contact frame ESAZX 169. _3 _1 1N.. SK A 1SCA022150R5110 0,03 N NC _4 _2 1N.C. SK B 1SCA022150R5370 0,03 Description Recomm. Type rder number Weight order quantity [kg] _3 _1 1 N.. 10 A1G 10 1SCA022353R N NC 1 N.C. _4 _2 10 A3G 01 1SCA022456R [kg] A4B1C 1SCA022193R0150 0,03 Single pole contacts. Max. 2 contacts. > 3 mm contact gap. Technical data: U e = 24V,/ e (DC12) =6A; U e = 250V/ e (AC 15) = 5A, e (DC12) =0.1A; U e = 440V/ e (AC 15) = 2A Mounting frame has to be ordered separately. Technical data: U e = 120V,/ e (AC 15) = 8A, U e = 230V,/ e (AC 15) = 6A, U e = 400V,/ e (AC 15) = 4A, U e = 690V,/ e (AC 15) = 2A, U e = 125V,/ e (DC 13) = 1.1A, Auxiliary contacts for S Mini and for S Snap-on mounting to the switch, P20, cable cross section x 2.5 mm 2. Early-break type. th = 16A, U i = 690V. Rated operational currents, AC 15 : 6A/230V, 4A/400V, 2A/690V. All n.o. contacts are provided with a positive opening feature. For S Mini: Max. 6 auxiliary contacts mountable onto the side with the mounting frame SZ4. Mounting frame has to be ordered separately. For S : Max. 6 auxiliary contacts mountable onto the side. No frames needed. Max. 2 auxiliary contacts mountable between the poles, which can be used as -contacts, see a function chart below. For S : Max. 6 auxiliary contacts per switch side mountable on to the side. No frames needed. Max. 3 auxiliary contacts mountable between the poles, of which two contacts can be used as -contacts and one contact is used as -indication contact. SZ 4 Function charts for S contacts: Auxiliary contact frames for S Mini Handle position Main contacts 0 open open closed Between poles Aux. / contacts N.. closed open closed indication contact N.. closed open open 1) nly in types S Side of Switch Handle position Main Aux. / contacts contacts N.. 0 open open closed open open closed S00544A ESAZX 169 For A1G10 and A3G01 auxiliary contacts Frame for auxiliary contacts and for fuse monitor. Max. 6 auxiliary contacts (type A_G_) can be fitted - Mounting on the left side of the switch SZ4 1SCA022530R0200 0,06 For SK _ auxiliary contacts Not suitable for side operated switches. Max. 6 auxiliary contacts (type SK ) can be fitted - Mounting on the right side of the switch ESAZX 169 1SCA022196R9360 0,06 38 Low Voltage Products

28 N N N N PowerLine rdering nformation Switch Fuses S Accessories S01219A S01202A S01210A SS 63G1 SS 160G3_ SS 160T1_ S00968A SZ1, 2 SN_160_ S00955A S01207A S01287 S00542A ESAZX N, solid neutral FAW 00 ESAZG 5, ESAZS36 Terminal shrouds Description Type rder number Weight [kg] For S An optional single pole shroud which is needed for maintaining P20 rating for wire sizes <10 mm 2. A one package, size 6 pieces, is needed for full protection (3-pole switches). Snap-on fitting. SS 63G1 1SCA022533R For S , all shrouds provided with knock-outs - For up and down connections Single pole terminal shroud, P20. Snap-on fitting. For cable lug connections, L = 67,5, transparent. SS 160T1 1SCA022502R A compact sized three pole terminal shroud, P20. Snap on fitting. *) Suitable for types...03 or L = 34, grey. SS 160G3 1SCA022556R Single pole terminal shroud, P20.Snap-on fitting. Low type. L = 34. Transparent SS 160T1L 1SCA022556R Neutral Links For S Mini and S , detachable, mounting on the side of the switch or on to the mounting plate or DN-rail. Max. wire H W D Mounting Type rder number Weight [mm] holes [kg] 16 mm 2 Cu , distance 32 ESAZX 171 1SCA022197R For S , detachable, mounting on to the base plate or DN-rail. 16 mm 2 Cu , distance 32 SZ 1 1SCA022481R mm 2 Cu , distance 35 SZ 2 1SCA022481R For S _03, detachable, mounting on the top of the mechanism. t does not increase the foot print area of a three pole switch. N-terminal distance to L1-terminal = identical to phase-to-phase terminal distance. Terminal width 15 mm SN 160 1SCA022560R Terminal width 20 mm SN 160W 1SCA022561R Solid Links Suitable for switch Fuse type Packing Type rder number Weight [pcs] [kg] S 32D... S 160D DN 00 1 FAW 00 1SCA022003R S 32B... S 100B, BS 88: A2...A3 1 ESAZG 5 1SCA022057R S 125B...S 200B BS 88: A4 1 ESAZS 36 1SCA022044R Connecting accessories For S Description Cable cross Packing Type rder number Weight section [mm 2 ] [pcs] [kg] Terminal clamp set for Cu-cables, terminal width 15 mm ZXA 7 1SCA022008R Terminal clamp sets for Al/Cu-cables, terminal width: 15 mm (ZXB 1), 20 mm (ZXB 2) 1) ZXB 1 1SCA022169R ZXB 2 1SCA022119R ZXA 7 S01286A S00368A Connection kit between S and ABB type A contactors The kit includes three tin coated adapter pieces, M8x30 screws and washers. Suitable for S-types:-03, -04, -30, -13N, -31N2. SZA 15 1SCA022509R SZA 15 S Mini and S have protected terminal clamps as standard; S include terminal bolt sets: M6X20, in types S 100_W...160_W: M 8 x 25. 1) For more information about Al/Cu terminal clamps, see brochure ZX 1 A GB. Low Voltage Products 39

29 PowerLine rdering nformation Switch Fuses S Accessories Fuse Monitor - includes the auxiliary contacts 1N + 1NC. Snap-on fitting on to the switch fuse. See brochure FM20GB REMARK. For S Mini the frame for fuse monitor and auxiliary contacts type SZ4 has to be ordered separately. See auxiliary contacts. S00908A Rated voltage Type rder Number Weight [Vac] [kg] FM 260 1SCA022459R FM 690 1SCA022459R Mounting accessories for fuse monitor ncludes 6 pcs crimp terminals. Suitable for switches Flat terminal Type rder Number Weight size [mm] [kg] S Mini, S FMZX 2 1SCA022475R FM 260, 690 S00954A FMZX2 SD25 S00543A Blown fuse indicators (DPMM) Striker type fuse is needed. Description Type rder number Weight [kg] For S Mini for 3-pole switches SD 25P3 1SCA022192R for 4-pole switches, fused neutral SD 25P4 1SCA022196R For S F for 3-pole switches SD 63P3 1SCA022502R for 4-pole switches, fused neutral SD 63P4 1SCA022502R For S F for pole switches SD 160P4 1SCA022502R S00370A Fuse replacement handles For Description Packing Type rder number Weight DN-fuse sizes [pcs] [kg] 000,00,1,2,3 Compact 1 FAE 504 1SCA022007R ,00,1,2,3 690 V 1 FAE 505 1SCA022137R FAE 505 S00538A W_5DS_ S00061C ESAZW 2 Conversion kits for the combination switches For S Mini Shaft distance Type rder number Weight [mm] [kg] Conversion kit of 6-pole switches for 3-pole switches Both switches work simultaneously. The standard handle can be used. The switches (2 pcs), the handle kit have to be ordered separately (nly one handle and one shaft are required.) WP5DS1 1SCA022190R Conversion kit of 8-pole switches for 4-pole switches WP5DS2 1SCA022208R Change-over switch mechanism for 3-pole switches ncludes plastic handle type HB65J6E011 with indication. The switches(2 pcs) and the operating shaft have to be ordered separately. See "ptional shafts". WC5DSH1 1SCA022190R Change-over switch mechanism for 4-pole switches WC5DSH2 1SCA022208R Mechanical interlock kit for 3-pole switches Prevents one switch from closing to N -position, if the other is not in FF - position. The switches (2 pcs) and the handle kits have to be ordered separately. (Two handles and shafts are required) WM5DS1 1SCA022191R Mechanical interlock kit for 4-pole switches WM5DS2 1SCA022208R For S The attachment levers are provided with holes, enabling different shafts distances. The combination kits can be mounted either horizontally or vertically. Switches have to be ordered separately. ncludes handle HB145J12 with -, N-FF -indication and 2 shafts. 6- and 8-pole switches 45 + (0...13) x 15 ESAZW 2 1SCA022078R For S Change-over switches ncludes mhandle HB80J6E011 with -0- indication and 2 shafts (0 10) x 15 ESAZW 1 1SCA022064R S01234A ESAZW 1 FF N 40 Low Voltage Products

30 PowerLine Switch Fuses S A Dimension drawings Contents: Dimension Drawings Front operated switch fuses S Mini Front operated switch fuses S Front operated switch fuses S Side operated switch fuses S Mini Side operated switch fuses S Side operated switch fuses S Contact Functions Low Voltage Products 41

31 S01121A PowerLine Dimension Drawings Front operated Switch Fuses S S Mini EN A 3G01 A 1G10 SZ 4 38 S B12_ S F12_ S 30A12_ A4B1C max 1+1 S B22_ S F22_ S 30A22_ A 3G01 A 1G10 SZ 4 74 A4B1C max 1+1 Ø S00579B ,5 14,3 30,8 27, ,6 14,3 4,5 30,8 27, EC UL 198C CSA C22.2 No.106 NFC63210, S25F1210 S32F1214 S30A12J S30A12CC BS88-2 EC S20B12A1 S32B12A1 S32B12A2 BS88-6 S32B12F1 S20B22A1F S32B22A1F S25F2210F S32F2214F EC NFC63210, S20B22A1N1 S25F2210 S32B22A1N1 S32F2214 S32B22A2N1 S32B22F1N1 S25F2210N1 S32F2214N1 BS88-2 EC S20B22A1 S32B22A1 BS88-6 S32B22F1 S EN50023 EN50022 A 3G01 A 1G10 51,5 A 3G01 A 1G10 max ,7 A 3G01 A 1G10 96,5 A 3G01 A 1G10 max , Ø S _B_, -F_, -C_, -J_ S _D_ , ,4 40,5 7,8 33 3, , ,5 7,8 64,7 M4 46,5 46, ,5 10,5 92 NFC 14x51 NFC 22x58 UL J30, J60 DN 000 CSA C30, C60 BS 88 A2, A3 DN 00 S 50F12 S 32B12 S 32D12 S 63F12 S 63B12 S 63D12 S 60J12 S 32C12 S 60C12 NFC 14x51 NFC 22x58 UL J30, J60 DN 000 CSA C30, C60 BS 88 A2, A3 DN 00 S 50F22 S 32B22 S 32D22 S 32_22N1 S 63F22 S 63B22 S 63D22 S 63_22N1 S 60J22 S 32_22F S 32C22 S 63_22F S 60C22 42 Low Voltage Products

32 PowerLine Dimension Drawings Front operated Switch Fuses S S DN- and NFC-types, S 100 BS-types Mechanism between the poles 129,5 67, , / 67,5 S 125D12 S 100F12 S 100B12 S 160D12 S 125F12 19,7 S 160 W 9x13 A 3G01 13 A 1G10 EN ,5x7 EN50023 A 3G01 A 1G10 max 1+1 nd max 1 19,7 15 Ø4 A 3G01 A 1G10 S 125D22 S 100F22 S 100B22 S 160D22 S 125F22 19,7 S 160 W 9x13 A 3G01 A 1G10 5,5x7 A 3G01 A 1G10 max 1+1 nd max 1 19,7 15 Ø4 A 3G01 A 1G10 Ø , , ,5 110, S _B_, -F_, -C_ 112,5 87 S _D_ , ,5 6,6x10, , ,5 6,6x10, ,5 S_12 120,5 129,5 120,5 129,5 M5 169 NFC 22x58 S 100F12 S 125F12 DN 000 BS 88 A2-A3 DN 00 S 100B12 S 125D12 S 160D12 NFC 22x58 BS 88 A2-A3 S 100F22 S 100B22 S 125F22 DN 000 DN 000 DN 00 DN 00 S 125D22 S 160D22F S 160D22 S01118A 110,5 M5 S_ S _B04F BS 88 A2-A3 S _F04F NFC 22x58 S _B04N2 S _F04N2 S _D04N2 S BS-types, S 100 CSA-types Mechanism between the poles 129,5 67, , /67,5 A 3G01 A 1G10 13 EN ,5x7 EN50023 S 125B12 S 100C12 S 160B12 19,7 S 160 W 9x13 nd max 1 A 3G01 A 1G10 max1+1 19,7 15 Ø4 A 3G01 A 1G10 S 125B22 S 100C22 S 160B22 S 160 W A 3G01 A 1G10 5,5x7 nd max 1 A 3G01 A 1G10 max ,7 19,7 15 9x13 Ø4 A 3G01 A 1G10 Ø66 110, , ,5 110, S 100C_ S 125B_ 120, , ,5 6,6x10, , ,5 6,6x10, ,5 S_12 120,5 129,5 120,5 129,5 M5 169 CSA C60 CSA C100 BS 88 A2-A4 S 100C12 S 125B12 CSA C60 CSA C100 BS 88 A2-A4 S 100C22 S 125B22 CSA C60 CSA C100 BS 88 A2-A4 S 100C22F S 125B22F S 100C22N2 S 125B22N2 S01116A 110,5 M5 S_ Low Voltage Products 43

33 PowerLine Dimension Drawings Front operated Switch Fuses S S DN- and NFC-types, S 100 BS-types Mechanism at the end of the switch fuse , ,5 67, / 67,5 13 S 125D03 S 100F03 S 100B03 S 160D03 S 125F03 19,7 S 160 W 9x13 EN50022 EN50023 A 3G01 A 1G10 5,5x7 nd max 1 A 3G01 A 1G10 max ,7 15 Ø4 A 3G01 A 1G10 S 125D04 S 100F04 S 100B04 S 160D04 S 125F04 19,7 S 160 W 9x13 A 3G01 A 1G10 5,5x7 nd max 1 A 3G01 A 1G10 max ,7 15 Ø4 A 3G01 A 1G10 Ø , , ,5 110, S _B_, -F_, -C_ 112,5 75,5 S _D_ , ,5 6,6x10, , , ,5 6,6x10, ,5 S_03 120,5 129,5 120,5 129,5 M5 169 DN 000 NFC 22x58 BS 88 A2-A3 DN 00 S 100F03 S 100B03 S 125D03 S 125F03 S 160D03 DN 000 DN 000 NFC 22x58 BS 88 A2-A3 DN 00 DN 00 S 100F04 S 100B04 S 125D04 S 160D04F S 125F04 S 160D04 S01117A 110,5 M5 S_ S _B04F BS 88 A2-A3 S _F04F NFC 22x58 S _B04N2 S _F04N2 S _D04N2 S BS- and S 100 CSA-types Mechanism at the end of the switch fuse 129,5 67, , /67,5 13 EN50022 EN50023 S 125B03 S 100C03 S 160B03 19,7 S 160 W 9x13 A 3G01 A 1G10 5,5x7 nd max 1 A 3G01 A 1G10 max ,7 15 Ø4 A 3G01 A 1G10 A 3G01 A 1G10 5,5x7 S 125B04 S 100C04 S 160B04 19,7 S 160 W nd max 1 A 3G01 A 1G10 max ,7 15 9x13 Ø4 A 3G01 A 1G10 Ø66 110, , ,5 110, S 100C_ S 125B_ 120, , , ,5 6,6x10, , , ,5 6,6x10, ,5 S_03 120,5 129,5 120,5 129,5 M5 169 CSA C60 CSA C100 BS 88 A2-A4 S 100C03 S 125B03 CSA C60 CSA C60 CSA C100 CSA C100 BS 88 A2-A4 BS 88 A2-A4 S 100C04 S 125B04 S 100C04F S 100C04N2 S 125B04F S 125B04N2 S01115A 110,5 M5 S_ Low Voltage Products

34 PowerLine Dimension Drawings Front operated Switch Fuses S S 100 UL-types Mechanism between the poles , , ,5 34/ ,5 13 EN50022 EN50023 S 100J12 A 3G01 A 1G10 5,5x7 S 160 W nd max 1 A 3G01 A 1G10 max1+1 19,7 19,7 15 9x13 Ø4 A 3G01 A 1G10 S 100J22 A 3G01 A 1G10 5,5x7 S 160 W nd max 1 A 3G01 A 1G10 max ,7 19,7 15 9x13 Ø4 A 3G01 A 1G Ø66 110, , ,5 110,5 S ,6x10, , , , , ,5 6,6x10, ,5 S_12 120,5 129,5 120,5 129,5 M5 169 UL J100 S 100J12 UL J100 S 100J22 UL J100 S 100J22F S 100J22N2 110,5 M5 S_ S 100 UL-types Mechanism at the end of the switch fuses 201 Ø66 129, , , / 67, EN50022 EN A 3G01 A 1G10 5,5x7 S 100J03 S 100J04 nd max 1 S 160 W A 3G01 A 1G10 max ,7 19,7 15 9x13 Ø4 A 3G01 A 1G10 110, ,5 124 A 3G01 A 1G10 5,5x7 nd max 1 A 3G01 A 1G10 max 1+1 S 160 W 19,7 19,7 15 9x13 Ø4 A 3G01 A 1G ,5 110, , , , ,5 6,6x10, , , ,5 6,6x10, ,5 M5 S_03 120,5 129,5 120,5 129,5 169 UL J100 S 100J03 UL J100 S 100J04 UL J100 S 100J04F UL J100 S 100J04N2 S ,5 M5 S_ Low Voltage Products 45

35 PowerLine Dimension Drawings Side operated Switch Fuses S S Mini S BS30_ S FS30_ S BS40_ S FS40_ 45 EN A 3G01 A 1G10 SZ 4 38 A4B1C max A 3G01 A 1G10 SZ 4 74 A4B1C max N N FF Ø66 FF Ø ,5 14,3 30,8 27, ,6 14,3 4,5 30,8 27, S01120A EC UL 198C CSA C22.2 No.106 NFC63210, S25FS3010 S32FS3014 S30AS30J S30AS30CC BS88-2 EC S20BS30A1 S32BS30A1 S32BS30A2 BS88-6 S32BS30F1 S20BS40A1F S32BS40A1F S25FS4010F S32FS4014F S20BS40A1N1 EC S32BS40A1N1 NFC63210, S32BS40F1N1 S25FS4010 S25FS4010N1 S32FS4014 S32FS4014N1 BS88-2 BS88-6 EC S32BS40F1 S20BS40A1 S32BS40A1 S EN50023 EN50022 A 3G01 A 1G10 51,5 A 3G01 A 1G10 max ,7 A 3G01 A 1G10 96,5 A 3G01 A 1G10 max , S _BS_, -FS_, -CS_, -JS_ S _DS_ 64, M4 4 3, ,4 40,5 7,8 3, , , , ,5 46, ,5 10,5 Ø66 S01123A 65 NFC 14x51 NFC 22x58 UL J30, J60 DN 000 CSA C30, C60 BS 88 A2, A3 DN 00 S 50FS30 S 63FS30 S 60JS30 S 32CS30 S 60CS30 S 32BS30 S 63BS30 S 32DS30 S 63DS30 NFC 14x51 NFC 22x58 6 UL J30, J60 DN 000 CSA C30, C60 BS 88 A2, A3 DN 00 S 50FS40 S 32BS40 S 32DS40 S 32_S40N1 S 63FS40 S 63BS40 S 63DS40 S 63_S40N1 S 60JS40 S 32_S40F S 32CS40 S 63_S40F S 60CS40 46 Low Voltage Products

36 S01113A PowerLine Dimension Drawings Side operated Switch Fuses S S DN- and NFC-types, S 100 BS-types EN50022 EN50023 S 125DS30 S 100FS30 S 100BS30 S 160DS30 S 125FS30 20 A 3G01 S 160 W A 1G10 9x13 15 A 3G01 nd A 1G10 5,5x7 6,6x10,6 max 1 max Ø66 S 125DS40 S 100FS40 S 100BS40 S 160DS40 S 125FS40 20 A 3G01 S 160 W A 1G10 9x13 15 A 3G01 nd A 1G10 5,5x7 6,6x10,6 max 1 max Ø , , S01114A 5 35,5 S_BS, -FS 112,5 S _DS 131 Ø , ,5 202, Ø , ,5 237, ,5 M5 S_S , , ,5 S_S40 DN 000 DN 00 BS 88 A2-A3 NFC 22x58 S 125D30 S 100B30 S 100F30 S 160D30 S 125F30 DN 000 DN 000 BS 88 A2-A3 NFC 22x58 DN 00 DN 00 S 160D40F S 125D40 S 100B40 S 100F40 S 160D40 S 125F40 M5 204 BS 88 A2-A3 S _B40F NFC 22x58 S _F40F S _B40N2 S _F40N2 S _D40N2 S BS-types, S 100 CSA-types EN50022 EN50023 S 125BS30 S 100CS30 S 160BS30 20 S 160 W 9x13 A 3G01 A 1G10 5,5x7 15 A 3G01 nd A 1G10 6,6x10,6 max 1 max Ø66 S 125BS40 S 100CS40 S 160BS40 20 A 3G01 S 160 W A 1G10 9x13 15 A 3G01 nd A 1G10 5,5x7 6,6x10,6 max 1 max Ø , , S _BS_ S_CS_ 35,5 120,5 5 Ø ,5 Ø , ,5 202, , , ,5 M5 S_ ,5 120, ,5 M5 S_40 CSA C60 CSA C100 S 100CS30 BS 88 A2-A4 S 125BS30 CSA C60 CSA C100 CSA C60 BS 88 A2-A4 CSA C100 BS 88 A2-A4 S 100C04F S 100C04N2 S 100C04 S 125B04 S 125B04F S 125B04N2 204 Low Voltage Products 47

37 PowerLine Dimension Drawings Side operated Switch Fuses S S 100 UL- types S 100JS30 S 100JS , A 3G01 A 1G10 5,5x S 160 W 9x13 A 3G01 nd A 1G10 6,6x10,6 max 1 max A 3G01 A 1G10 5,5x S 160 W 9x13 A 3G01 nd A 1G10 6,6x10,6 max 1 max / 67,5 EN50022 EN50023 Ø66 Ø , , S01167A 35,5 120,5 5 Ø , , ,5 65 Ø , , , ,5 202, , , ,5 M5 S_ ,5 120,5 129,5 110,5 S_40 UL J100 S 100JS30 UL J100 S 100J04F S 100J04N2 UL J100 S 100J04 M Low Voltage Products

38 PowerLine Contact Functions Switch Fuses S N and FF-functions of auxiliary and main contacs FF FF N N S00373B α places of auxiliary contacts and ind Main contacts No auxiliary contact Nc auxiliary contact No auxiliary contact Nc auxiliary contact Closing pening close open close open open close open close open close S mini A4B1C A4B1C Main contacts No auxiliary contact Nc auxiliary contact FF N Change over contacts A1G10 A3G01 No auxiliary contact Nc auxiliary contact S A1G10 A3G01 Main contacts No auxiliary contact Nc auxiliary contact FF N A1G10 A3G01 No auxiliary contact Nc auxiliary contact S A1G10 A3G01 Main contacts No auxiliary contact Nc auxiliary contact FF N A1G10 A3G01 No auxiliary contact Nc auxiliary contact S01201A A1G10 A3G01 ind No ind Nc FF N S Mini o o o o α Main contacts No auxiliary contact Nc auxiliary contact 0 0 S01054A SK A + ESAZX 169 SK B + ESAZX no 1 nc FF 0 N Low Voltage Products 49

39 PowerLine Switch Fuses ESA_PL, A Contents: Technical data rdering information Dimension drawings Contact Functions Low Voltage Products Low Voltage Products 51

40 52 Switch Fuse Range

41 Total safety for the user Fuse shrouds P 20 protected Fully-protected fuse housing, even from the top, preventing loose articles to fall in fuse contacts Various types for world-wide applications: Suitable fuses: DN, sizes 0...3, BS 88, B1...B4, C1...C3 UL (U.S.A.) and CSA (Canada), class J, class L, class T, CSA: class C perator independent quick make / quick break mechanism Fuse links are isolated on both sides of the fuse Self cleaning contacts, patented moving contact construction Auxiliary contacts New space saving neutral links Mounting on the top of the mechanism does not increase a foot print area of a three pole switch Wide selection of early break auxiliary contacts Two pole blocks offer up to 16 contacts All n.o. contacts are with positive opening operation, see drawing below. function - Easy and quick commissioning max 2 max 4+4 The auxiliary contacts enable testing without closing the main contacts. max

42 Fuse monitor Handles No danger for 2-phase motor loading, prevents unsafe neutral voltages perates with all standard fuses; striker-type fuses are not required, thus reducing overall costs No need for external supply voltage Wide voltage ranges, VAC and VAC, +/ - 10 % Safe and reliable EMC tested Fuse Monitor is automatically reset after the blown fuses have been replaced. ne trip contact, one alarm contact, and LEDs (red and green) Full operational ability even with phase unbalance Compact size Snap-on mounting for ESA switch fuses ncreased reliability with capacitor banks for side operated External front or side operated P65 handle with an adjustable shaft. Handles available in three colours: black, yellow/red and grey Defeatable door interlocking, even with P 65 protection class The door cannot be opened if the switch is padlocked in the FF position The handle can be padlocked in the FF position with three padlocks, thus preventing the door from opening, and closing the circuit during maintenance The handle cannot be padlocked in the FF position if any of the contacts are not totally open A robust metal handle as an optional extra 56 57

43 Side operated ESA _PL Easy to adapt for different applications From 1 pole to 4 pole front and side operated switch fuses. With conversion kits up to 6 and 8 pole switches. Change-over, mechanically inter-locked switch combinations can also be built using optional mounting kits n 4 -pole units, the fourth pole is fully rated The fourth pole is available as fusible or non-fusible Contents: PowerLine Switch Fuses ESA_PL, A Technical data rdering information DN-pattern BS-pattern Switch fuses for North-American market, 3-pole Side operated switch fuses, DN and BS-pattern Accessories ptional handles Extended shafts Shaft extension socket Auxiliary contact sets Fuse covers for ESA_PL Terminal shrouds Solid links Fuse handles Blown fuse indicators Fuse monitor Locking accessories Connecting accessories Conversion kits for the combination switches Neutral links Motor operator angle kit Dimension Drawings ESA, A, DN- and BS-pattern ESA, A, side operated Side-to side, plug-in and back termination available, see a brochure ESA 2 GB. Accessories Contact Functions Low Voltage Products Low Voltage Products 59

Technical Brochure. Switch Fuses DIN and NFC-Standard. Selection Table. Brochure OESA 2DIN GB Mallipohja. Low Voltage Products

Technical Brochure. Switch Fuses DIN and NFC-Standard. Selection Table. Brochure OESA 2DIN GB Mallipohja. Low Voltage Products Technical Brochure Switch Fuses DN and NFC-Standard Selection Table Brochure ESA 2DN GB 99-12 Mallipohja Powerline S switch fuses 20...160A, 690 V Unique patented design for the 21st century Total user

More information

PowerLine OS Switch Fuses A, 690V

PowerLine OS Switch Fuses A, 690V Technical Brochure PowerLine OS Switch Fuses 20...160 A, 690V Brochure OS 10 GB 99-04 9902CD04 ABB Control New Switch Fuse Range 2 3 Total user safety Total user safety Fuse carriers fully IP20 protected

More information

PowerLine Switch Fuses OESA_PL, A. Contents: Technical data... 9/2. Ordering information DIN-pattern... 9/3 BS-pattern...

PowerLine Switch Fuses OESA_PL, A. Contents: Technical data... 9/2. Ordering information DIN-pattern... 9/3 BS-pattern... Switch Fuses ESA_PL, A Contents: Technical data... /2 rdering information DN-pattern... /3 BS-pattern... /3 Accessories... /4 Dimension Drawings... /6 /1 Technical Data Switch Fuses ESA Technical Data

More information

Technical Brochure. Rotary Type Installation Switches A, 500 V. Brochure OT_M 22 GB D Low Voltage Products

Technical Brochure. Rotary Type Installation Switches A, 500 V. Brochure OT_M 22 GB D Low Voltage Products 94 D 5384 Technical Brochure Rotary Type nstallation Switches 16...160 A, 500 V Brochure T_M 22 GB 99-08 Low Voltage Products 9809CD03 Rotary Type nstallation Switches 16 A...160 A ew features for installation

More information

SwitchLine Switch-Disconnectors / Load Break Switches OT OT 160. Contents:

SwitchLine Switch-Disconnectors / Load Break Switches OT OT 160. Contents: SwitchLine Switch-Disconnectors / Load Break Switches T 16...12 - T 160 Contents: T 16...12 Selection table for T 16...12... /2 - /3 rdering information T 16...12... /4 - / Switch-Disconnectors Base and

More information

Low Voltage Switches. Fusegear Switch fuses OS and OSM

Low Voltage Switches. Fusegear Switch fuses OS and OSM Low Voltage Switches Fusegear Switch fuses OS and OSM Switch fuses OS 16...1250, OSM 32...1250 Contents 4 Product overview 6 Features 8 Technical data 18 Ordering information, manual operation 18 DIN-

More information

Product brochure. ABB Fusegear EasyLine Fuse switch disconnector

Product brochure. ABB Fusegear EasyLine Fuse switch disconnector Product brochure ABB Fusegear EasyLine Fuse switch disconnector 2 EasyLine Fuse Switch Disconnector ABB Fusegear Content Fuse protection 4 Technical Data 5 General 6 Apparatus overview 7 Electronic Fuse

More information

Breakers and Switches. Switches Switch-disconnectors OT and OTM

Breakers and Switches. Switches Switch-disconnectors OT and OTM Breakers and Switches Switches Switch-disconnectors OT and OTM Switch-disconnectors OT16...4000 and OTM40...2500 Features Product overview 4 High performance, compact solution 6 Technical data Switch-disconnectors,

More information

L O W V O L T A G E DISCONNECT SWITCHES G LO B A L L I N E OF PREMIUM C O M PA C T LOW VOLTAGE SWITCHGEAR

L O W V O L T A G E DISCONNECT SWITCHES G LO B A L L I N E OF PREMIUM C O M PA C T LOW VOLTAGE SWITCHGEAR L O W V O L T A G E DISCONNECT SWITCHES G LO B A L L I N E OF PREMIUM C O M PA C T LOW VOLTAGE SWITCHGEAR The safest way to switch power on and off in your industrial control panels. Your problem: You

More information

Low Voltage Products. SwitchLine, Load Break Switches / Switch-Disconnectors A, 690 V A, 1000 V

Low Voltage Products. SwitchLine, Load Break Switches / Switch-Disconnectors A, 690 V A, 1000 V SwitchLine, Load Break Switches / Switch-Disconnectors 16...160 A, 690 V 200...3150 A, 1000 V Brochure T_ETL 1 GB 01-05 1SCC301001C0201 N T16E3 N FF N FF N FF FF FF N N N FF FF FF N N T80E3 N N FF FF FF

More information

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A Non-fusible disconnect switches SRCO M UL 58 sircm_132_a sircm_133_a The solution for > ndustrial control systems Rotary switch SRCO M 3 x 8 A Toggle switch SRCO M 3 x 8 A + 2 auxiliary contacts Strong

More information

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A Non-fusible disconnect switches sircm_132_a sircm_133_a The solution for > Industrial control systems Rotary switch SIRCO M 3 x 80 A Toggle switch SIRCO M 3 x 80 A + 2 auxiliary contacts Competitive advantages

More information

Switch fuses OS , OSM

Switch fuses OS , OSM Switch fuses OS 16...1250, OSM 32...1250 Contents 4 Product overview 6 Features 8 Technical data 16 Ordering information, manual operation 16 Front operated switch fuses OS 25 Side operated switch fuses

More information

Low Voltage Apparatus. Technical Brochure. FuseLine HRC Fuse Links OFAA, OFAM. Brochure OF 1 GB ABB Control Oy

Low Voltage Apparatus. Technical Brochure. FuseLine HRC Fuse Links OFAA, OFAM. Brochure OF 1 GB ABB Control Oy Technical Brochure Low Voltage Apparatus FuseLine HRC Fuse Links OFAA, OFAM Brochure OF GB 96-03 ABB Control Oy 95MDN5447 HRC Fuse-Links OFAA and OFAM OFAA gg Fuse-Links for Overload and Short-Circuit

More information

SIRCO M and MV Universal load break switches from 16 to 160 A

SIRCO M and MV Universal load break switches from 16 to 160 A SRCO M and MV from 16 to 16 A The solution for Load break switches sircm_99_a > Main incoming load break > Distribution load break > Machine control > Local safety load break sircm_13_a 4 pole SRCO MV

More information

Switch-disconnectors OT , OETL 3150

Switch-disconnectors OT , OETL 3150 Switch-disconnectors OT 16...2500, OETL 3150 Contents 4 Product overview 6 Features 8 Technical data 18 Ordering information, manual operation 18 Front operated switch-disconnectors OT, OETL 24 Side operated

More information

Low Voltage Products. SwitchLine, Load Break Switches / Switch-Disconnectors A, 690 V A, 1000 V

Low Voltage Products. SwitchLine, Load Break Switches / Switch-Disconnectors A, 690 V A, 1000 V SwitchLine, Load Break Switches / Switch-Disconnectors 16...160 A, 690 V 200...3150 A, 1000 V Brochure T_ETL1 GB 04_06 1SCC301001C0201 N T16E3 N FF N FF N FF FF FF N N N FF FF FF N N T80E3 N N FF FF FF

More information

Low Voltage Products. Switches Switch-disconnectors OT and OETL

Low Voltage Products. Switches Switch-disconnectors OT and OETL Low Voltage Products Switches Switch-disconnectors OT and OETL Switch-disconnector IEC lth /A le /AC22A, 415V le /AC23A, 415V... OT16F OT63F OT100F OT160E OT25F OT80F OT125F OT40F 25 32 40 63 80 115 125

More information

FUSERBLOC CD. The universal Fuse Combination Switch FROM 20 TO 1250 A. Industrial Switching & Protection Systems

FUSERBLOC CD. The universal Fuse Combination Switch FROM 20 TO 1250 A. Industrial Switching & Protection Systems FUSERBLOC CD The universal Fuse Combination Switch FROM 20 TO 1250 A SOCOMEC GROUP SWITCHING PROTECTION & UPS Industrial Switching & Protection Systems SWITCHING FUSERBLOC CD THE UNIVERSAL FUSE COMBINATION

More information

Catalogue March InLine II - ZLBM/ZHBM Fuse Switch Disconnector

Catalogue March InLine II - ZLBM/ZHBM Fuse Switch Disconnector Catalogue March 2015 InLine II - ZLBM/ZHBM Fuse Switch Disconnector 2 1SEC312022B0202 ABB Catalogue Contents Introduction 1 Apparatus 2 Accessories 3 Technical Data 4 Cable terminations and cable shrouds

More information

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved

More information

Changeover & Bypass Sw it ches

Changeover & Bypass Sw it ches Changeover & Bypass Switches St ate of the art Manufacturing Facilit ies Haridw ar, Noida Ph-I & Noida Ph-II Plant Changeover & Bypass Sw it ches Introduction On Load Changeover Switches (with & without

More information

SD Series Non-Fused Load Switches

SD Series Non-Fused Load Switches SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load

More information

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A Fuse protection fuser_737_a_1_cat.eps fuser_738_a_1_cat.eps The solution for > Motor load break > Protection of industrial processes FUSERBLOC REAR / FRONT connections 3 x 250 A fuser_739_a_1_cat.eps Strong

More information

Breakers and Switches. Switches Change-over and transfer switches

Breakers and Switches. Switches Change-over and transfer switches Breakers and Switches Switches Change-over and transfer switches Change-over and transfer switches 16...2500 A Contents: 4 Product overview, features 8 Technical data 8 Manual, motorized and automatic

More information

Low Voltage Switches. Switches and fusegear Motorized switch-disconnectors OTM and switch fuses OSM

Low Voltage Switches. Switches and fusegear Motorized switch-disconnectors OTM and switch fuses OSM Low Voltage Switches Switches and fusegear Motorized switch-disconnectors OTM and switch fuses OSM Motorized switches OTM 60...2500, OSM 2...250 Contents Product overview 6 Features 8 Technical data 6

More information

An innovative technology

An innovative technology The range An innovative technology Description The new are load break switches that combine attractive style and optimised features due to their innovative design. This range, dedicated to industrial applications,

More information

Low Voltage Switches. Switches Switch fuses OS A Gamma series

Low Voltage Switches. Switches Switch fuses OS A Gamma series Low Voltage Switches Switches Switch fuses OS32...1 Gaa series Switch fuses for extreme conditions - OS 32 1 Gaa series Numerous applications require switch fuses that can withstand extreme conditions.

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A Fuse protection fuser_548_a cat The solution for > Motor load break. > Protection of industrial cabinet. FUSERBLOC 6 to 25 A Strong points fuser_52_a cat Function FUSERBLOC 2 to 4 A FUSERBLOC are manually

More information

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

Protection and Connection Motorized and automatic transfer switches IEC Technical guide Protection and Connection Motorized and automatic transfer switches IEC 61439 Technical guide Motorized change-over switches Uninterrupted power supply with motorized functionality ABB offers a wide variety

More information

SWITCH FUSES 3KL71 from 32A to 800A Description

SWITCH FUSES 3KL71 from 32A to 800A Description from 32A to 800A Description SWITCH FUSES 3KL71 3KL71 is a range of load-break switches suitable for making and breaking on load and disconnetting low voltage electrical circuits. They are commonly used

More information

Disconnect Switches. Bussmann. Bussmann Information Fax ~ Bussmann Worldwide Web ~

Disconnect Switches. Bussmann. Bussmann Information Fax ~ Bussmann Worldwide Web ~ Page Selection Guide Fusible 2 Non-Fusible 3 Handles 4 Disconnect Switches Fusible (30-800A) Features 5-6 Components 7 Accessories 8 Non-Fusible (16-3150A) Features 9 Components 10-14 Accessories 15 Mounting

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A Fuse protection fuser_548_a_1_cat The solution for > Motor load break > Protection of industrial processes FUSERBLOC 63 to 125 A Strong points fuser_532_a_1_cat Function FUSERBLOC 32 to 4 A FUSERBLOC are

More information

Motorized switch-disconnectors OTM 40 to 125 Amperes

Motorized switch-disconnectors OTM 40 to 125 Amperes Motorized switch-disconnectors OTM to 125 mperes With the new range of motorized-switch disconnectors, BB offers now a full range from to 2500 mperes. Thanks to the design, OTM...125 are a good solution

More information

Switches for PV applications Switch-disconnectors OTDC, OT and OTDCP

Switches for PV applications Switch-disconnectors OTDC, OT and OTDCP Breakers and Switches Switches for PV applications Switch-disconnectors OTDC, OT and OTDCP Switch-disconnectors OTDC16...250, OT315...630 and OTDCP16...32 Contents 4 Product overview 8 Technical data

More information

Switch disconnectors

Switch disconnectors Selection Load break switch disconnectors type LK3, 40-120 A Selection guide for 3 and 4-pole switch disconnectors General The LK3 range of switch disconnectors (lth: 40 A to 120 A) is designed for use

More information

Contents. Volume 5 Motor Control and Protection CA E December

Contents. Volume 5 Motor Control and Protection CA E December Rotary Disconnects.2 R5 Series Non-Fusible 16 80A Product Description R5 Series (UL 508 listed) products are manually operated modular switches. Load break switching and isolation provide safety solutions

More information

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A ATyS d M Remotely operated Transfer Switching Equipment Transfer switches new The solution for > Applications with an external ATS/AMF controller > Building Management Systems (BMS) atys-md_002_b_1_cat

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

01 Spectra Plus - Introduction

01 Spectra Plus - Introduction 01 Spectra Plus - Introduction Standard features Conforming to IS13947-2/EN60947 2 Compact dimensions Available in 3P & 4P High performance microprocessor protection release Wide overload setting from

More information

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches. disconnect 16A 31A, 0VAC 200-0A, 1000VDC Disconnect Disconnect ABB SwitchLine includes 16 different amperage sizes from 16A to 31A. The basic construction provides flexibility, safety, and high performance

More information

General information about motor protection

General information about motor protection Application guide General information about motor protection Typical construction of a motor starter Disconnect Switch UL 98 - UL489 CSA C22.2 # 4 CSA C22.2 # 5 Fuses SIRCO Non-Fusible Disconnect Switch

More information

1 Phase electronic contactor (SC 1)

1 Phase electronic contactor (SC 1) 1 Phase electronic contactor (SC 1) - Rated operational voltage up to 600VAC 50/60 Hz - Rated operational current up to 15/30A/50/63A AC-1 - Control voltage from or - Compact modular design 22.5, 45, or

More information

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI . Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,

More information

CI-TI Contactors and motor starters Types CI 61 - CI 98

CI-TI Contactors and motor starters Types CI 61 - CI 98 Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include

More information

SIRCOVER and SIRCOVER BY-PASS. Changeover switches with fully visualised breaking from 125 to 3200 A. 274 General Catalogue SOCOMEC

SIRCOVER and SIRCOVER BY-PASS. Changeover switches with fully visualised breaking from 125 to 3200 A. 274 General Catalogue SOCOMEC and Manual Changeover Switches BY-PSS appli_114_a svr_099_b_1_cat svr_059_a_1_cat Changeover switches with fully visualised breaking from 125 to 3200 Function products are manually operated multipolar

More information

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A The solution for Load break switches sirco-ul_022_b_1_cat > Power distribution. Strong points sirco_093_b_1_cat SIRCO 3 x 200 A > Reliability. > Safety of property and personnel. > Simplicity. > Easy assembling.

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

SIRCOVER. Manual transfer switches from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for. Strong points

SIRCOVER. Manual transfer switches from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for. Strong points Transfer switches svr_151_a The solution for > Manufacturing industry > Power distribution SRCOVER 2 Strong points > complete range > Easy connections > Stable positions svr_125_a_1_cat Bypass TS 0 Conformity

More information

Electronic overload relays EF205 and EF370

Electronic overload relays EF205 and EF370 Data sheet Electronic overload relays EF205 and EF370 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage SENTRON Configuration Manual Edition 10/2015 siemens.com/lowvoltage 2 Introduction LD main control and EMERGENCY-STOP switches up to 250 A 4 Introduction 7 Front mounting 10 Floor mounting 11 Distribution

More information

3NP1 Fuse Switch Disconnectors up to 630 A

3NP1 Fuse Switch Disconnectors up to 630 A Switch Disconnectors 3NP1 Fuse Switch Disconnectors up to 630 A Introduction Overview All key product features at a glance available for all sizes Connection of circular conductors and laminated conductors

More information

Thermal overload relay TF140DU and TF140DU-V1000

Thermal overload relay TF140DU and TF140DU-V1000 Data sheet Thermal overload relay TF140DU and TF140DU-V1000 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against

More information

Switches for photovoltaic applications Switch-disconnectors OTDC and OTDCP

Switches for photovoltaic applications Switch-disconnectors OTDC and OTDCP Contact us ABB Oy Breakers and Switches P.O. Box 622 FI-65101 Vaasa, Finland Phone: +358 10 22 11 Fax: +358 10 22 45708 E-Mail: firstname.surname@fi.abb.com www.abb.com The technical data and dimensions

More information

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A Non-fusible disconnect switches SIRCO UL98 Non-fusible switches standards UL and CSA sirco-ul_022_b_1_cat The solution for > Power distribution sirco_093_b_1_cat SIRCO 3 x 200 A Strong points > Reliability

More information

Manual motor starter MS132

Manual motor starter MS132 Data sheet Manual motor starter MS132 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

THE SANTON FCS-TYPE SWITCH DISCONNECT. Superior Switch Solutions

THE SANTON FCS-TYPE SWITCH DISCONNECT. Superior Switch Solutions THE SANTON FCS-TYPE SWITCH DISCONNECT Superior Switch Solutions The technical information given in this table applies to and pole fuse combination switches. A B NOMINAL RATING 0A A FUSE COMBINATION SWITCHES

More information

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES DCX-M changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES FOR COMMERCIAL BUILDINGS AND DCX-M In = 63 A Quality & design CONFORM TO EN/IEC

More information

UL 508 Non-Fusible Disconnect Switches

UL 508 Non-Fusible Disconnect Switches UL 508 Non-Fused (M163 M803) The M-series Load Break Switch is the most compact industrial-grade switch on the market. Capable of making or breaking loads up to 600V (UL), it is suitable as a motor disconnect.

More information

Breakers and Switches. Switches for PV applications Switch-disconnectors OTDC, OT and OTDCP

Breakers and Switches. Switches for PV applications Switch-disconnectors OTDC, OT and OTDCP Breakers and Switches Switches for PV applications Switch-disconnectors OTDC, OT and OTDCP Switch-disconnectors OTDC16...250, OT315...630 and OTDCP16...32 Contents 4 Product overview 8 Technical data

More information

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A Transfer switches The solution for > Genset < 90 kva > Heating systems > Climate control > Ventilation systems > Telecommunications atys-s_018_a Strong points Function products are 4 pole remotely operated

More information

CATALOG. EasyLine XLP Fuse Switch Disconnector poles

CATALOG. EasyLine XLP Fuse Switch Disconnector poles CATALOG EasyLine XLP Fuse Switch Disconnector 1-2-3-4 poles 2 E A S Y L I N E X L P F U S E S W I TC H D I S C O N N E C TO R 1-2 - 3-4 P O L E S Contents 004 005 Introduction EasyLine XLP 006 007 Introduction

More information

UL 508 Non-Fusible Disconnect Switches

UL 508 Non-Fusible Disconnect Switches UL 508 Non-Fused (M163 M803) The M-series Load Break Switch is the most compact industrial-grade switch on the market. Capable of making or breaking loads up to 600V (UL), it is suitable as a motor disconnect.

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

1489-M Circuit Breakers

1489-M Circuit Breakers Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Terminal design helps prevent wiring misses Scratch- and solventresistant printing Suitable

More information

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400 Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,

More information

UL/CSA Non-fused Disconnect Switches

UL/CSA Non-fused Disconnect Switches Product Selection UL/CSA Non-fused Disconnect Switches Cat. No. 194R-N30-1753 Cat. No. 194R-J100-1753 Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

More information

Thermal overload relay TF65 and TF96

Thermal overload relay TF65 and TF96 Data sheet Thermal overload relay TF65 and TF96 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against overload and

More information

15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 160 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays are the alternative to the thermal overload relays. An electronic overload relay offers reliable and fast protection

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request 125 to 4000 A sirco_353_a_1_cat sirco_296_a_1_cat sirco_300_b switches are manually operated or motorised multipolar load break switches. They break on and off under load and provide safety isolation for

More information

Low Voltage Products. SwitchLine OT change-over switches 160, 200, 250, 315, 400, 630 and 800 Amps. Catalogue OT7GB 05_09 1SCC301012C0201

Low Voltage Products. SwitchLine OT change-over switches 160, 200, 250, 315, 400, 630 and 800 Amps. Catalogue OT7GB 05_09 1SCC301012C0201 Low Voltage Products SwitchLine OT change-over switches 160, 200, 0, 315, 400, 630 and 800 mps Catalogue OT7G 05_09 1SCC301012C0201 Ith / Ie /C22, 415V Ie /C23, 415V OT160E OT160E_W OT200E OT200E_W OT0E

More information

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?...

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?... Load break switches Load break switches for all your applications.................................... Why choose a load break switch designed for photovoltaic applications?............. Load break switch

More information

Contactor Types CI 61-98

Contactor Types CI 61-98 MKING MODERN LIVING POSSIBLE Data sheet Contactor s CI 6-98 Contactors CI 6, CI 73, CI 86 and CI 98 switch powers of up to 30 kw, 37 kw, 45 kw and 55 kw respectively under 3 380 V C-3 loads. ccessories

More information

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4. Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

Wall mounted switchgear

Wall mounted switchgear Contents Safepact 2... pages /2 to / Enclosed MCCBs 6 to 60A... page /2 Enclosed switch disconnectors 100 to 60A... page / Earth leakage.... page /4 Auxiliaries and accessories... page /5 Enclosed Interpact...page

More information

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function The solution for Load break switches sdmat_066_a cat > Main switchboard > Distribution panel > Motor load break unction SIDERMT 4 x 630 External front operation SIDERMT are manually operated 3 or 4 pole

More information

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

Product index. 4 - Manual motor protectors. Phone: Fax: Web:  - Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

SENTRON 3NP1 Fuse Switch Disconnectors up to 630 A

SENTRON 3NP1 Fuse Switch Disconnectors up to 630 A Introduction Overview All key product features at a glance available for all sizes Connection of circular conductors and laminated conductors Fuse monitoring possible throughout Busbar supports can be

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information

MS25, MST25, MS20, MST20

MS25, MST25, MS20, MST20 Versions: - MS25 with thermal and magnetic releases - MST25 with a thermal release - MS20 - with thermal and magnetic releases for single-phase consumers - MST20 with a thermal for single phase consumers

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

Main switches in accordance with European standard directives

Main switches in accordance with European standard directives Main switches in accordance with European standard directives N N ABB y ABB Switches in accordance with EU Directives New concept n order to dismantle technical barriers in commerce, the Council of the

More information

Panel Mount Switches

Panel Mount Switches Panel Mount Switches Load Break Switches Fuse Switches Changeover Switches IPD Industrial Products is an Australian owned distributor of a wide variety of low voltage electrical and automation products

More information

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU Medium Voltage Distribution PIX Air Insulated Switchgear up to kv PIX Air Insulated Switchgear up to kv The PIX system has been designed in accordance with international (IEC) standards, and gives an optimal

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

A compact range of Switch-Disconnectors with the capacity to add auxiliary and neutral block options to the basic load break switch block.

A compact range of Switch-Disconnectors with the capacity to add auxiliary and neutral block options to the basic load break switch block. PNE ISOTORS Craig & Derricott has a range of products designed specifically for control panel and switchboard construction. Most panels require a means of electrical isolation and the can offer variants

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions to 00 A Accessories Enclosed Characteristics M e atysm_007_a cat M s atysm_0_a cat products are and 4pole switches remotely controlled by volt free contacts ( ) or automatic transfer switches ( ). They

More information

Phase + Neutral, neutral on right side

Phase + Neutral, neutral on right side 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications Descriptive bulletin Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications General overview Reliable, low maintenance and economical Load Interrupter

More information

Technical data OT16E3 OT160E3 UL & CSA

Technical data OT16E3 OT160E3 UL & CSA Technical data OT16E3 OT16E3 UL & CSA UL & CSA Catalog number 3 pole OT16E3 OT25E3 OT32E3 OT45E3 OT63E3 OT3E3 OT6E3 OT1E3 OT16E3 Approvals 1 2 pole N/A N/A N/A N/A N/A N/A N/A N/A UL98 & EC 3 pole UL58

More information

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A Load break switches SIRCO MV PV sircm-pv_010_a_1_cat The solution for > Residential buildings > Buildings > Solar parks Strong points SIRCO MV PV 1000 V - 80 A direct operation > Modular device > Patented

More information

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE Switch disconnectors A modular and flexible range Contact gap 7 mm (norm 5.5 mm) Reversible terminal feature ÿ IN ENCLOSURE - Degree of protection: up to IP 66 - For 25A to 100A size switches (see Ithe

More information

LV switch-disconnectors. Interpact Merlin Gerin 40 to 2500 A. Catalogue. We do more with electricity

LV switch-disconnectors. Interpact Merlin Gerin 40 to 2500 A. Catalogue. We do more with electricity LV switch-disconnectors Catalogue Merlin Gerin 40 to 2500 A We do more with electricity LV switch-disconnectors The various low-voltage applications 2 from 40 to 2500 A 4 Compact from 80 to 1250 A 5 Masterpact

More information

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation

More information