1 INVERTER/CHARGER INVERTER/CHARGER 1012/1024/1512/1524/2012/2024/3024/ /4048/5048/6048 Appliances PC TV Aircnditining Fridge Washing machine

2 TABLE OF CONTENTS General Precautins...1 Persnnel Precautins...1 Intrductin...2 Features...2 Prduct Overview...2 LCD Panel Descriptin...2 Back panel printing descriptin...3 Side panel printing descriptin...3 AC terminal panel printing descriptin...4 Installatin...4 Unpacking and inspectin...4 Preparatin...4 Munting the Unit...4 Operatin...8 Operatin key instructins...8 Setting key instructins...8 LCD display...10 Operating mde descriptin...11 AGS functin...11 AGS functin infrmatin...11 Dry cntact perating vltage...12 BTS functin...12 BTS functin descriptin...12 Cnnect inverter and battery...12 Cmmunicatin Upper Cmputer Mnitring directins...12 The peratin steps are as fllws...12 Specificatins...14 Inverter Mde Specificatin...14 AC Mde Specificatin...15 Charge Mde Specificatins...15 Fault Mde...16 Truble shting...17 LCD display instructin When inverter alarm, even it back t recvery mde. We must restart inverter t clear fault. Fault cde Fault Fan fault Over temperature DC vltage t high DC vltage t lw Output shrt circuit in DC mdel Output ver vltage Output ver lad Output ver current Output lw vltage in DC mdel Fault instructin Fan stp run Output shrt circuit: shrt circut test fault 05 Output ver vltage: V utput>135v/270v 500ms fault 06 verlad: 100%<Lad<110% alarm per every secnd (5min later inverter cutff utput and fault 07) 110%<Lad<125% alarm per every secnd (60s later inverter cutff utput and fault 07) Lad>125% alarm per every secnd (10s later cut ff utput and fault 07) Inverter Output ver current: 1-3K: I rms>40a. 4-6K: I rms>80a 200ms fault 51 Output lw vltage: V utput<85v/170v 500ms fault 58 Truble shting If machine enters int fault mde, please remve input pwer. And accrding t the table, deal with the fllwing prblems. LED/Buzzer LCD Explanatin / Pssible cause What t d Buzzer beeps cntinuusly and red LED is n Fault cde 01 Fan stp run Check the fan. Fault cde 02 Temperature f machine is t high. Pwer ff and waiting fr minute Fault cde 03 Battery vltage is t high. Check the battery specificatins Fault cde 04 Battery vltage is t lw. Check the battery specificatins Fault cde 05 Output shrt circuited Remve yur lad and restart Fault cde 06 Inverter utput vltage is high. Fault cde 07 Over lad Decrease yur lad Fault cde 51 BTS ver temperture: T battery>65 C 1s 1 time fr 1min then fault alarm 02; T battery<60 C recvery Inverter ver temperture: T >90 C 1s1time fr 1min then fault alarm 02; T <85 C recvery inv Battery ver vltage: DC>V(charge vltage+1v)/12v alarm fr 30s then fault cde 03 Over vltage recvery: DC<V (charge vltage+1v)-0.2v/12v Lw vltage alarm: DC<V (cutff+0.5v)/12v Alarm recvery: DC>V (cutff+0.5)+0.2/12v Lw vltage fault: DC<V cutff fault cde 04 Output ver current Return t repair center Fault cde 58 Output vltage is t lw. Decrease yur lad inv Check if wiring is cnnected well and remve abnrmal lad. -17-

3 Charge mde: Charge current adjustable Charge cureent adjustable: 10A~max (adjust by every 5A) Battery vltage Shrt circuit prtectin Over charge prtectin rule Charge Stage Transitin Definitin Fault Mde LED instructin LED LED state infrmatin Off N AC input LED AC(green) LED Inv(yellw) LED Fault(red) BUZZER instructin Buzzer state Buzzer ff Buzzer beep Buzzer n vltage charge vltage cure max current On Blink Off On Off On Blink Vdc/20-29Vdc/40-58Vdc breaker Bat V charge vltage+1v/battery,1s 1 time fr 30s then alarm 03 Bst CC Bst CV Bst FV Bst CC Stage: If A/C input is applied, the charger will run at full current in CC mde until the charger reaches the bst vltage. Bst CV Stage: the charger will keep the bst vltage in Bst CV mde until the charge current less 6A cntinue 1minute r keep the bst vltage time mre than 2hurs. Then drp the vltage dwn t the flat vltage. Flat Stage: In flat mde, the vltage will stay at the flat vltage. If the A/C is recnnected, the charger will reset the cycle abve. CC charge cure CV max 2hurs charge vltage cure FV stage1 stage2 stage3 current I<6A after 1min r CV mre 2hurs AC nrmal AC ver range Inverter mde nrmal fault cautin infrmatin nrmal cautin fault WARNING! This manual cntains imprtant instructins fr all Inverter/Charger mdels that shall be fllwed during installatin and maintenance f the inverter. The fllwing cases are nt within the scpe f warranty 1. Out f warranty. 2. Series number was changed r lst. 3. Battery capacity was declined r external damaged. 4. Inverter was damaged caused f transprt shift, remissness, ect external factr 5. Inverter was damaged caused f irresistible natural disasters. 6. Nt in accrdance with the electrical pwer supply cnditins r perate envirnment caused damage. General Precautins Befre using it, read all instructins and markings: (1) inverter (2) battery (3) user manual CAUTION: 1. T reduce risk f injury, charge nly lead-acid rechargeable batteries. If custmer use flded batteries, batteries must be maintained regularly. Other battery types may cause damage and injury. 2. D nt expse it t rain, snw r any type liquids. Inverters are designed fr indr use. 3. D nt disassemble it. Take it t qualified service center when service r repair is needed. 4. T prevent the risk f electric shck, discnnect all wiring befre attempting any maintenance r cleaning. Only turning ff the unit will nt reduce the risk. WARNING: 1. Prvide ventilatin frm the battery cmpartment t utdrs. The battery enclsure shuld be designed t prevent accumulatin and cncentratin f hydrgen gas at the tp f the cmpartment. 2. NEVER charge a frzen battery and cnnect such 12V/24V/48V batteries t inverter. 3. Input/utput AC wiring mustn t be less than 12AWG and nt rated fr 75 C r higher. Battery cable mustn t be rated fr 75 C r higher and shuld be n less than 4AWG /6AWG gauge. 4. Pay special attentin when wrking with metal tls arund batteries. Batteries shrt-circuiting culd cause an explsin. 5. Read the battery installatin and maintenance instructins carefully befre perating. Persnnel Precautins 1. Better t prepare plenty f fresh water and sap nearby in case battery acid cntacts skin, clthing r eyes. 2. Avid tuching eyes while wrking near batteries. 3. NEVER smke r allw a spark r flame near batteries. 4. Remve persnal metal items such as rings, bracelets, necklaces, and watches when wrking with batteries. Batteries may prvide heavy shrt-circuit current, which wuld be enugh t make metal melt and causes severe burn. 5. If a remte r autmatic generatr start system is used, disable the autmatic starting circuit r discnnect the generatr t prevent accident during servicing

4 Intrductin This inverter is applicable t different markets demands, it matches different vltage AC 120V/240V, als can set utput vltage, frequency, charging vltage, charging current, it s available t wrk in split phase pwer envirnment. Features: Pure sine wave utput Friendly user interface 3 Steps charging MFD (multi-functin display) Overlad and shrt-circuit prtectin Set charging vltage/charging current. Battery lw vltage shutdwn pint can be set t 10/10.5/11V Pwer-save mde Set utility pririty/ Battery pririty Set utility input wide/narrw range Inverter vltage can be set t 110/115/120 Inverter frequency can be set t 50/60Hz Set utility charging n/ff switch LCD Panel Descriptin High vltage alarm Save mde AC Mde Specificatin AC parameter Input wavefrm Nminal input vltage Max input vltage Input frequency Output wavefrm Overlad prtectin Output shrt circuit Efficiency(AC mde) Transfer time AC TO DC Transfer time DC TO AC AC input vltage range: (±5V) Add +1V/battery: (high vltage ne secnd ne time/after 30s fault 03) ( V) + 1V fr 12V mdel ( V) + 2V fr 24v mdel ( ) + 4V fr 48v mdel Lad 40W(110V)/80W(220V) Pure sine wave 220Vac / 230Vac / 240Vac 270Vac MAX 50HZ/60HZ (aut sensing) Same as input wavefrm Breaker + sftware prtectin Breaker+ sftware prtectin >95% lad, full battery) 15ms(max) 15ms(max) mdel range Lw cutff Lw recver High cutff High recver 9 220V narrw wide AC<180V F<40HZ AC<140V F<40HZ AC>190V F>45HZ AC>150V F>45HZ AC>270V F>70HZ AC>270V F>70HZ AC<265V F<65HZ AC<265V F<65HZ Charge Mde Specificatins Max charge current: (±5A) mdel 1K 1.5K 2K 3K 4K 5K 6K V 30A 45A 60A 24V 20A 25A 30A 40A 60A 1 48V 20A 30A 35A 40A Min charge current 10A. change by every 5A. INVERTER Charge mde AC range: Setting Lw vltage Charge mde recver Charge mde AC>265V Stp charge AC<260V Charge recver 1. Switch ON/OFF: POWER ON/OFF Switch 2. MENU 3. UP 4. DOWN 5. ENTER 6. AC LED 7. INV LED 8. FAULT 9. LCD 220V AC wide range AC<155V Stp charge 40<F<70HZ charge AC>160V Charge recver

5 AC INPUT PROTECT AC INPUT PROTECT USB REMOTE PORT The SlarPwerMnitr will aut scan cmmunicatin prt. Back panel printing descriptin: Ep Data Primary AppParamters Themes Prts Inf Pc1600 primary setting COM7:Ntwrking COM3:ReadWrite Grid vltage 0 V Battery vltage 13.2 V Scan fr Device Grid frequency 0 Hz Battery current A Lcal COM3 EP3300 External Output vltage V Battery temperature 0 C 1 Output frequency 50 Hz Battery SOC 92 % Machine Inf Lad current 0 A Transfrmer TEMP 28 C Machine type EP3300 Lad pwer 0 W Buzzer state Nrrnal Sftware versin Rated pwer ** 2000 W Lad percent 0 % Wrk state BACKUP 6 1-3K Back Panel Battery class 12 V System fault System alarm Battery Vltage Wait fr a mment, Pwer Mnitr will wrk nrmally. 48VDC Mnitr sftware functin peratin Specific functin Operatins f the mnitring sftware, please refering t the HELP dcs after the cnnectin is successful. 1 Battery Negative Specificatins Inverter Mde Specificatin Mdel Rated pwer(w) Pwer Factr Wave frm Output vltage RMS Output frequency Inverter efficiency(peak) Overlad Surge rating Capable f starting electric mtr Battery vltage Minimum start vltage Lw battery cut ff Lw battery alarm 1KW 1.5KW 2KW 3KW 4KW 5KW 6KW 1 Pure sine wave 110V/115V/120VAC(220V/230V/240VAC)±10% 50HZ r 60HZ (±0.3HZ) >80% 100%<Lad<110% (alarm 5min then stp utput and fault cde 07) 110%<Lad<125% (alarm 60s then stp utput and fault cde 07) Lad>125% (alarm 10s then stp utput and fault cde 07) 3000VA 4500VA 6000VA 9000VA 12000VA 15000VA 15000VA 1P 1.5P 1.5P 2P 3P 12VDC/ /48VDC 48VDC 11VDC/22VDC/44VDC (lw vltage fault cde04) 10/10.5/11V fr 12V mdel 20/21/22V fr 24V mdel 40/42/44V fr 48v mdel Add 0.5V/battery: (lw battery alarm ne secnd ne time) (10/10.5/11V) +0.5Vdc fr 12V mdel (20/21/22V) +1Vdc fr 24v mdel (40/42/44V) +2Vdc fr 48v mdel 1. Battery -/+ 2. REMOTE PORT 3. BTS 4. AGS Side panel printing descriptin: HOT1 N HOT2 N HOT1 HOT AC Side Panel 4-6K Back Panel 5. USB 6. AC INPUT PROTECT: Input prtect breaker 120V/15A MAX 5 Battery Psitive 1. :HOT1 -N120VAC/110 VAC/115VAC 2. : HOT2 -N120VAC/110 VAC/115VAC 3. :HOT1 -HOT2240VAC/220 VAC/230VAC 4. AC INPUT:HOT1 -HOT2240VAC/220 VAC/230VAC 5.15AMAX JFCI/NEMA 5-15R Output 110V/115V/120V Scket

6 AC terminal panel printing descriptin V/230V/240V CLIP V/115V/120V CLIP 3. AC INPUT 220V/230V/240V CLIP Install the sftware: Slar Pwer Mnitr Put the CD in the cmputer CD driver, install the sftware Slar Pwer Mnitr (Prper install fllwing the steps) SlarPwerMnitr Setup dtnetfx40-full-x86-x64.exe msi.msi msi1.cab SarPwerMnit.exe AC terminal panel Installatin Unpacking and inspectin Befre installatin, please inspect whle unit. Be sure that nthing inside the package is damaged. Yu shuld have received the fllwing items inside f package. User manual X 1 Sftware CD X 1 Cmmunicatin cable X 1 Battery cables (RED/BLACK) X 2 Chse Slar Pwer Mnitr. exe and install. SlarPwerMnitr Setup Advanced Installer Preparatin Befre cnnecting all wirings, please take ff bttm cver by remving eight screws as shwn belw: SarPwerMnit has been successfully installed. x C rm Open the PwerMnitr,turn n the machine. Munting the Unit Cnsider the fllwing pints befre selecting where t install: D nt munt the inverter n flammable cnstructin materials. Munt n a slid surface. Install this inverter at eye level in rder t read the LCD display clearly. Fr prper air circulatin t dissipate heat, require a clearance abut 50 cm t the side and 80 cm abve and belw the unit. The ambient temperature shuld be between 0 C and 40 C t ensure ptimal peratin. The recmmended installatin psitin is t be adhered t the wall vertically. Be sure t keep ther bjects and surfaces as shwn in the diagram t guarantee sufficient heat dissipatin and t have enugh space fr remving wires. SUITABLE FOR MOUNTING ON CONCRETE OROTHER NON-COMBUSTIBLE SURFACE ONLY. Desktp shrtcut Icn Sar Pwer Mnitr.exe PwerMnitr seach Data Prts Scan fr Device Lcal << AppParamters Themes Help searching

7 Dry cntact perating vltage Set Lw Shutdwn Vltage Operatin Vltage Restring Vltage Install the unit by screwing fur screws 10V/20V/40V DC<10.5V/21V/42V DC>13.5V/27V/54V 10.5V/21V/42V DC<11V/22V/44V DC>13.5V/27V/54V 11V/22V/44V DC<11.5V/23V/46V DC>13.5V/27V/54V That is when the dry cntact is engaged at DC<set lw shutdwn pint + 0.5V (battery lw vltage warning pint), at DC>13.5V. (12V mdel) BTS functin BTS functin descriptin: The inverter cllects the battery temperature thrugh the BTS prt, based n 25 Cwith each rise f 1 C, the charging vltage drps by 18mV/1 at the set charging vltage (up t 60 C). BTS dwn charge vltage is based n drps f bst vltage and flat vltage. Using an ptinal battery temperature cable t cnnect the inverter and battery. USB Bts wire Cmmunicatin Upper Cmputer Mnitring directins: Mdel EP3300LV use the mnitring sftware: Slar Pwer Mnitr fr cmmunicatin. This sftware supprts the cmmunicatin functin fr varius mdels f ur cmpany. The sftware will send the COM Prt and inverter mdel autmatically. The peratin steps are as fllws: Cnnect the Inverter and Cmputer. Cnnect the inverter with a cmmunicatin cable t the cmputer with RS232 cmmunicatin prt. (If the cmputer des nt have RS232 cmmunicatin prt, then yu need t use RS232 t USB cmmunicatin adapter fr cnnectin, and need t install RS232 t USB cmmunicatin drive). USB Usb wire 1-3K Inverter Case 4-6K Inverter Case DC Wiring Suggestin It is suggested t keep battery bank as clse as pssible t inverter. battery cable length 1m is suggested. Please find fllwing minimum wire size. If DC cable lnger than 1 m, please use thicker battery cables t bear pwer current ging thugh. Mdel Battery VltageType Wire Type 1KW 1.5KW 2KW 12VDC 12VDC 12VDC 6AWG 6AWG 4AWG 6AWG 2AWG 4AWG Mdel 3KW 4KW 5KW 6KW Battery Vltage Type 48VDC 48VDC 48VDC 48VDC Wire Type 3AWG 6AWG 2AWG 4AWG 3AWG 3AWG Please cnnect cable size thicker enugh, r cnnect several cmbined thin cables tgether t be same strng. Battery bank shuld be kept clse t inverter; The shrter and thicker cables, the better the system perfrmance. Please fllw battery cnnectin steps belw: Assemble battery ring terminal. Cnnect all battery packs as units requires. Battery cable and terminal size suggestin: It's suggested t cnnect at least 100Ah capacity battery pack fr 1KW-3KW mdels, at least 200Ah fr 4KW-6KW mdels. NOTE: Please nly use sealed lead acid battery r sealed GEL/AGM lead-acid battery. Insert the ring terminal f battery cable int inverter t battery cnnectr, make sure the blts are tightened with trque f 2-3Nm. Pay special attentin t battery back and inverter are cnnected rightly, als ring terminals are tightly screwed t the battery terminals

8 Operating mde descriptin Operatin mde Descriptin LCD display Fault mde If any fault has happened, the machine will enter t the mde. And fault cde is displayed n the LCD. Line mde Input pwer will prvide energy t lad directly. And it will charge the battery at the same time. If vltage f input pwer is utside f sectin, the machine will switch t battery mde. WARNING: Shck Hazard Installatin must be perfrmed with care due t high battery vltage in series. CAUTION!!D nt place anything between the flat part f the inverter terminal and the ring terminal. Otherwise, verheating may ccur. CAUTION!!D nt apply antixidant substance n the terminals befre terminals are cnnected tightly. CAUTION!! Befre making the final DC cnnectin r clsing DC breaker/ discnnectr, be sure psitive(+) must be cnnected t psitive(+) and negative(-) must be cnnected t negative(-). AC Input/Output Cnnectin CAUTION!! Befre cnnecting t AC input pwer surce, please install a separate AC breaker between inverter and AC input pwer surce. This will ensure inverter can be discnnected safely during maintenance and fully prtected frm ver current f AC input. Suggestin AC breaker: 50A fr 1KW-3KW, 80A fr 4KW-6KW. CAUTION!! Please dn't cnnect the utput wring t "Grid" terminal r cnnect the grid wring t the "Lad" terminal. WARNING! All wiring must be perfrmed by a qualified persnnel. WARNING! It's very imprtant t use apprpriate cable fr Grid cnnectin fr system safety and efficient peratin. T reduce injury risk, please use the prper suggested cable size as belw. Battery mde The unit will get energy frm battery and prvide t lad. AGS functin AGS functin infrmatin The AGS functin is that the inverter will start the generatr autmatically via the dry cntact when the battery is lw vltage. Nte: The generatr must have dry cntact functin. If yu cnnect AC grid and Generatr t Inverter input at the same time, the interlck device shuld be installed between generatr utput and inverter input. (T ensure the utility and generatr will nt prvide pwer t inverter at the same time. It desn t need t be installed if nly cnnect generatr). PC AC Wiring We recmmend using 10-16AWG wire t cnnect AC terminal blck. There are 3 different ways t cnnect AC wire t terminal blck. All wirings are CE cmpliant, call ur tech supprt if yu are nt sure abut hw t wire any part f yur inverter. TV Lad Interlck unit AC INPUT Pwer Grid AC Wiring 1-6KW 120V/240V single phase Input: HOT1 +HOT2 + G Output 120V: HOT1 +N + G Output 120V: HOT2 +N + G Output 240V: HOT1 +HOT2 + G HOT1 N HOT2 N HOT1 HOT2 Air-cnditining Fridge BAT INPUT BAT CHARGER Generatr Battery Washingmachine Suggested cable requirement fr AC wires Mdel 1-3KW 4-6KW Gauge 12-14AWG 10-12AWG Trque Value Nm Nm

9 LCD display: The sftware material N. & versin N shall be displayed n LCD Screen when switch n. Default Page: Output Vltage and Output Frequency. The Battery vltage and rated pwer shall be displayed n the LCD screen when switch n. As this shwn in Screen:3024 Input Vltage and Input Frequency. Please fllw steps belw t implement Lad/Grid cnnectin: Befre Lad/Grid cnnectin, be sure t pen DC prtectr first. Remve insulatin sleeve 10mm fr six cnductrs. And shrten phase L and neutral cnductr N 3 mm. Insert grid wires accrding t plarities indicated n terminal blck and tighten terminal screws. Be Sure t cnnect PE prtective cnductr( )first. AC INPUT Cnnectin Grund (yellw-green) HOT1 (brwn r black) HOT2 (brwn r black) HOT2 HOT1 HOT1 N N HOT2 L Battery Vltage and Current. Lad Pwer and Percentage. WARNING: Be sure that AC pwer surce is discnnected befre hard-wire it t the unit. BAT and Inverter Temperature Then, insert Lad wires accrding t plarities indicated n terminal blck and tighten terminal screws. Be sure t cnnect PE prtective cnductr( )first Cnnectin Grund (yellw-green) HOT1 LINE (brwn r black) N Neutral (blue r white) HOT2 LINE (brwn r black) HOT2 L HOT1 N N HOT1 HOT2 HOT2 HOT1 N N HOT1 HOT2 HOT1 L N HOT2 N HOT1 HOT1-N HOT2-N HOT1-HOT2 Make sure the wires are securely cnnected CAUTION: Appliances such as air cnditiner are required at least 2-3 minutes t restart because it's required t have enugh time t balance refrigerant gas inside f circuits. If a pwer shrtage ccurs and recvers in a shrt time, it will cause damage t yur cnnected appliances. T prevent this kind f damage, please check manufacturer f air cnditiner if it's equipped with time-delay functin befre installatin. Otherwise, this inverter will be triggered verlad fault and cut ff utput t prtect yur appliance but smetimes it still causes internal damage t the air cnditiner

10 Operatin 13 AC charging setting Rated current(default) 10A~Rated current. Regulatin step 5A 17 Bst vltage setting 14.1V(default) Range f adjustment V 13.5V(default) Range f adjustment V 18 Flating charging setting 19 Battery lw vltage shutdwn pint setting 10.5V(default) Range f adjustment 10-11V INVERTER Operatin key instructins: Switch buttn t cntrl the machine On and ff. There are fur buttns: MENU, UP, DOWN, ENTER. Via UP and DOWN can check the varius parameters display. Lng press MENU t enter the setting menu page, MENU and ENTER turn ver the menu page, UP and DOWN t set the parameters. After setting, lng press ENTER 2s t exit, except the inverter frequency and inverter vltage parameters, The setting parameters are nt saved t the EEPROM. The EEPROM is saved nly when the parameters are nrmally set. (T ensure that the parameters can be successfully saved, s every time after setting the parameters need restart the machine) SBU Battery lw vltage pwer pint SBU Battery high vltage inverter pint LCD back light settings 11.5V(default) 13.5V(default) LCD ON LCD OFF(default) Range f adjustment V If yu chice SBU, when the battery vltage less than value, the inverter will wrk in AC mdel Range f adjustment 13V-14.0V If yu chice SBU, when the battery vltage mre than value cntinue 1min, the inverter will wrk in DC mdel. The LCD back light n. Press any buttn t light up cntinue 1min. Setting key instructins: MENU Functin key Functin descriptin Utility pririty(default) If chice UTI, the inverter wrk in AC mdel until AC cut ff r ver the AC range. 24 Buzzer switch settings Buzzer ON(default) Buzzer OFF 01 Battery/AC pririty setting Battery pririty vde: Wide(default) The inverter wrk in AC mdel if battery less 20set value. The inverter wrk in DC mdel if battery mre than 21set value cntinue 1min. If set Wide, the AC range V. 27 Save mde switch settings SEN Sdi(default) Save mde enable inverter is set t detect the lad every 5/30 secnds Save ff The save mdel disenable Utility pwer range setting Inverter vltage setting NRU: Narrw 110V(default) If set NRU,the AC range V. (110/115/120) Search time settings in Save mde AC charging switch settings 5s(default) 5s inverter is set t detect the lad every 5 secnds. 30s inverter is set t detect the lad every 30 secnds. AC charging n(default) AC charging ff 50HZ(default) 60HZ UP Page up key 04 Inverter frequency setting DOWN Page dwn key ENTER Cnfirm the exit key

NEXT UPS Systems MANTIS II Tower 750/1000/1500 Installation and user manual English

NEXT UPS Systems MANTIS II Tower 750/1000/1500 Installation and user manual English NEXT UPS Systems MANTIS II Twer 750/1000/1500 Installatin and user manual English CONTENT IMPORTANT SAFETY INSTRUCTIONS... 1 1. Intrductin... 4 2. Descriptin f Features... 4 3. Package Cntents... 4 4.

More information

EP12M248 7 Stage Automatic Smart Battery Charger, Desulphuration& Maintainer 12V, 2 / 4 / 8A FOR AGM, GEL AND WET BATTERIES USER MANUAL

EP12M248 7 Stage Automatic Smart Battery Charger, Desulphuration& Maintainer 12V, 2 / 4 / 8A FOR AGM, GEL AND WET BATTERIES USER MANUAL EP12M248 7 Stage Autmatic Smart Battery Charger, Desulphuratin& Maintainer 12V, 2 / 4 / 8A FOR AGM, GEL AND WET BATTERIES USER MANUAL THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS 1

More information

EnergyBar 6. Setup Guide

EnergyBar 6. Setup Guide EnergyBar 6 Setup Guide WELCOME Cngratulatins n yur purchase f the Apex EnergyBar 6! The EnergyBar 6 allws the Apex system t cntrl up t six 230 vlt items such as lights, pumps, fans, heaters, chillers

More information

FIRST: Top battery (closest to the arm) SECOND: Middle battery. LAST: Top battery (furthest from arm)

FIRST: Top battery (closest to the arm) SECOND: Middle battery. LAST: Top battery (furthest from arm) Hw t Install the Batteries Hw t Hld the Lamp: The InteliEnergy Lamp selectin switches utilize the same technlgy as cell phnes: Capacitive Tuch. This assures the ultimate in lngevity because there are n

More information

Trouble Shooting Guide for AFVK-SP Series Valve Kit (AF-4000 Series Gas Valves)

Trouble Shooting Guide for AFVK-SP Series Valve Kit (AF-4000 Series Gas Valves) Truble Shting Guide fr AFVK-SP Series Valve Kit (AF-4000 Series Gas Valves) AFVK-SP, AFVK-SP-H/L, AFVK-SP-MH/L AFVK-SP Series Valve Kit Truble Shting Guide (AF-4000 Series) TABLE OF CONTENTS General Infrmatin

More information

Car Refrigerator PFN-C-WEA-25/35/45/55

Car Refrigerator PFN-C-WEA-25/35/45/55 Car Refrigeratr PFN-C-WEA-25/35/45/55 Accessries available separately:- Prtective Transit Bag AC0V -240Vt DC 2 V Pwer Adaptr Please read this manual carefully befre using yur unit. Sectin Page Key Prduct

More information

INVERTER/CHARGERS EVOLUTION SERIES. Off-Grid Power Solutions. How an Inverter/ Charger. Works... ORDER NOW

INVERTER/CHARGERS EVOLUTION SERIES. Off-Grid Power Solutions. How an Inverter/ Charger. Works... ORDER NOW D yu yu need reliable AC pwer in a vehicle, remte lcatin r fr emergency back-up? Samlex s inverter/charger is THE chice fr a cmplete ff-grid pwer slutin. Off-Grid Pwer Slutins LUTION SERIES S Sine 1 Pure

More information

ABTQ-103 rev 01 Last review:

ABTQ-103 rev 01 Last review: INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR ABTECH PCS Cntrl Statin Purpse f Instructins Wrking in hazardus areas, the safety f persnnel and plant depends n cmplying with all relevant safety

More information

E+ Battery Care Guide

E+ Battery Care Guide Electric Mtin Systems, LLC 45150 Business Curt, Suite 300 Dulles, VA 20166 USA E+ Battery Care Guide Welcme! Yur E+ Hub Battery Pack is a pwerful, sphisticated, and imprtant part f yur E+ Electric Bicycle.

More information

Introduction Specifications Structure & Performance Assembly Folding Operation Care & Maintenance...

Introduction Specifications Structure & Performance Assembly Folding Operation Care & Maintenance... n Intrductin... 3 Specificatins... 4 Structure & Perfrmance... 5 Assembly... 6 Flding... 7 Operatin... 8-12 Care & Maintenance... 13-15 2 P a g e Read and fllw all instructins, warnings, and ntes in this

More information

CS369-R51I Thank you very much for purchasing our air conditioner.

CS369-R51I Thank you very much for purchasing our air conditioner. OWNER'S MANUAL CONDITIONER REMOTE CONTROLLER ILLUSTRATION The design and specificatins are subject t change withut prir ntice fr prduct imprvement. Cnsult with the sales agency r manufacturer fr details.

More information

Volume 1.1 OPERATIONAL MANUAL MODEL: CG-211Y PIPE TORCH/BURNER MACHINE. by BLUEROCK Tools

Volume 1.1 OPERATIONAL MANUAL MODEL: CG-211Y PIPE TORCH/BURNER MACHINE. by BLUEROCK Tools Vlume 1.1 OPERATIONAL MANUAL MODEL: CG-211Y PIPE TORCH/BURNER MACHINE by BLUEROCK Tls UNPACKING THE ITEM Cautin: This machine is packed tgether with items that may be sharp, ily and verly heavy bjects.

More information

HIGH POWER RGB LED SERIES. The HB Series Advantage! Architectural Illumination Systems!

HIGH POWER RGB LED SERIES. The HB Series Advantage! Architectural Illumination Systems! The HB Series Advantage SGS listed cnfirming t UL Standard 2108 & 8750 Certified t CSA Standard C22.2 N.9 LED Life f 50K+ hurs, under nrmal perating cnditins Lw wattage, lw heat, lw vltage (12DVC & 24VDC

More information

Safe Handling of High Voltage Electrical components in Electrical End of Life Vehicles

Safe Handling of High Voltage Electrical components in Electrical End of Life Vehicles Safe Handling f High Vltage Electrical cmpnents in Electrical End f Life Vehicles The fllwing infrmatin is extracted frm the dcument Safe Handling f High Vltage Electrical cmpnents in Electrical End f

More information

BC7 BATTERY CABINET INSTALLATION / OPERATION / MAINTENANCE

BC7 BATTERY CABINET INSTALLATION / OPERATION / MAINTENANCE BC7 BATTERY CABINET INSTALLATION / OPERATION / MAINTENANCE 1. INTRODUCTION... 3 2. PRECAUTIONS... 3 3. INSPECTION UPON RECEIPT OF GOODS... 4 3.1 GENERAL... 4 3.2 VISIBLE DAMAGE... 4 3.3 CONCEALED DAMAGE...

More information

Installation instructions: 13 Pin Electrical system for towing hitch

Installation instructions: 13 Pin Electrical system for towing hitch General data Part number Westfalia Vehicle Manufacturer Vehicle 321 538 300 153 ZGB 1T0 055 204 Vlkswagen Turan MY 2003> 321 538 391 105-005 - 33/07 Imprtant ntes Read the installatin manual prir t starting

More information

30/40/50L Rechargeable Fridge/Freezer. Thank you for choosing our Rechargeable Fridge Freezer

30/40/50L Rechargeable Fridge/Freezer. Thank you for choosing our Rechargeable Fridge Freezer 30/40/50L Rechargeable Fridge/Freezer Thank yu fr chsing ur Rechargeable Fridge Freezer Please Read This Manual Carefully Befre Using Yur Unit. User Manual Mdel: P30/P30A,P40/40A, P50/P50A 173Wh/11.1V

More information

Installation Guide Contigo 6100

Installation Guide Contigo 6100 Installatin Guide Cmmercial Vehicle Prductivity and Security The is a high-perfrmance beacn designed fr cmmercial prductivity and security. It is ideally suited t installatins in delivery and service fleets

More information

DriveCam Unit Installation Instructions

DriveCam Unit Installation Instructions DriveCam Unit Installatin Instructins Installatin f the DriveCam Unit is nt cmplicated, thugh care must be taken t avid specific prblems. Sme vehicles require additinal cnsideratin t determine the ptimum

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Observer Zning Bard ZONE0101ZP6 These instructins must be read and understd cmpletely befre attempting installatin Safety Labeling and Signal Wrds DANGER, WARNING, CAUTION, and

More information

PSS INSTALLATION INSTRUCTIONS

PSS INSTALLATION INSTRUCTIONS PSS INSTALLATION INSTRUCTIONS Imprtant - Read Befre Starting! Befre starting yur installatin carefully read the fllwing warnings and instructins. Failure t prperly fllw the warnings and instructins culd

More information

Delta RPI-M50A - India. Grid-Tied Solar Inverter RPI-M50A. The Power Behind Competitiveness. Product Features

Delta RPI-M50A - India. Grid-Tied Solar Inverter RPI-M50A. The Power Behind Competitiveness. Product Features The Pwer Behind Cmpetitiveness Delta - India Grid-Tied Slar Inverter Prduct Features Transfrmerless Inverter Dual MPP Trackers Peak Efficiency up t 98.6% Cnnects up t 10 Strings Ergnmic Grip Design Ultra

More information

Tips & Technology For Bosch business partners

Tips & Technology For Bosch business partners Tips & Technlgy Fr Bsch business partners Current tpics fr successful wrkshps N. 35/2011 Gasline injectin Invented fr life Lambda sensr Knw-hw frm the market leader Bsch, innvative cmpany and wrld's largest

More information

Model: TM-3 INSTALLATION AND OPERATION INSTRUCTIONS

Model: TM-3 INSTALLATION AND OPERATION INSTRUCTIONS 120 Mdel: TM-3 INSTALLATION AND OPERATION INSTRUCTIONS IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS DO NOT ATTEMPT TO INSTALL OR OPERATE INTRODUCTION This Wired Wall Timer system was

More information

PRAIRIE 360 4X4 (KVF360-A/C), PRAIRIE 360 2X4 (KVF360-B), PRAIRIE 650 4X4 (KVF650-A/B), PRAIRIE 700 4X4 (KVF700-A/B/D),

PRAIRIE 360 4X4 (KVF360-A/C), PRAIRIE 360 2X4 (KVF360-B), PRAIRIE 650 4X4 (KVF650-A/B), PRAIRIE 700 4X4 (KVF700-A/B/D), SERVICE REPLACES: Please discard ATV 07-02 dated 4/5/07 MODEL: PRAIRIE 360 4X4 (KVF360-A/C), PRAIRIE 360 2X4 (KVF360-B), PRAIRIE 650 4X4 (KVF650-A/B), PRAIRIE 700 4X4 (KVF700-A/B/D), KFX700 (KSV700-A/B/C),

More information

Delta RPI-M50A. Grid-Tied Solar Inverter RPI-M50A. The Power Behind Competitiveness. Product Features

Delta RPI-M50A. Grid-Tied Solar Inverter RPI-M50A. The Power Behind Competitiveness. Product Features The Pwer Behind Cmpetitiveness Delta Grid-Tied Slar Inverter Prduct Features Transfrmerless Inverter Dual MPP Trackers Peak Efficiency up t 98.6% Cnnects up t 12 Strings Ergnmic Grip Design Ultra Cmpact

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Observer Zning Panel ZONE0101ZP6 These instructins must be read and understd cmpletely befre attempting installatin Safety Labeling and Signal Wrds DANGER, WARNING, CAUTION, and

More information

Uninterruptible Current Supply USV V / 1.2 Ah

Uninterruptible Current Supply USV V / 1.2 Ah Uninterruptible Current Supply USV 011 +24 V / 1.2 Ah The USV 011 Uninterruptible current supply is used t buffer the +24 V supply f an Industry PC (C-IPC, SIPC). The +24 V supply is nrmally cnnected t

More information

GENUINE ACCESSORIES INSTALLATION INSTRUCTIONS SECURITY SYSTEM KIT CONTENTS SHOCK SENSOR F-D15 WINDOW DECAL (QTY 2) F-D16

GENUINE ACCESSORIES INSTALLATION INSTRUCTIONS SECURITY SYSTEM KIT CONTENTS SHOCK SENSOR F-D15 WINDOW DECAL (QTY 2) F-D16 GENUINE ACCESSRIES INSTALLATIN INSTRUCTINS PART NUMBER: 0000-8F-N03 NTE: NT CMPATIBLE WITH REMTE START SYSTEM, PART# 0000-8F-N02 SECURITY SYSTEM KIT CNTENTS APPLICABLE MDELS: 2007>MAZDA CX-9 WITHUT ADVANCED

More information

LED Driver Feedback Signs

LED Driver Feedback Signs LED Driver Feedback Signs Installatin Instructins (029-04151-0000) Nvember 2012 Slar Kit 35AH / 55W 70AH / 55W 70AH / 85W M75-SOLAR-000S M75-SLR70-000S M75-SOLAR-000C E. 5676 Seltice Way Pst Falls, Idah

More information

Tools Required. Installation. Step 1. Headlight lense removal (Driver's side shown, Passenger side similar)

Tools Required. Installation. Step 1. Headlight lense removal (Driver's side shown, Passenger side similar) Tls Required Phillips Screw Driver (crner lamps) Flat Head Screw Driver (ptinal fr headlight cver) Pliers (handy t have) Electrical Tape Sturdy Cpper Wire (t use as a wire fish) 10mm Scket r Wrench (grund

More information

Generator/Loadbank Quick Connection Switchboard

Generator/Loadbank Quick Connection Switchboard / Generatr/Ladbank Quick Cnnectin Switchbard FS2-Series Generatr/Ladbank Quick Cnnectin Slutins Brchure www.apt-pwer.cm 433 N. 36 th Street Lafayette, IN 47905 (765) 446-2343 ALN: 516 Rev. 01 Standard

More information

Volume 1.1 OPERATIONAL MANUAL MODEL: CG-211C PIPE TORCH/BURNER MACHINE. by BLUEROCK Tools

Volume 1.1 OPERATIONAL MANUAL MODEL: CG-211C PIPE TORCH/BURNER MACHINE. by BLUEROCK Tools Vlume 1.1 OPERATIONAL MANUAL MODEL: CG-211C PIPE TORCH/BURNER MACHINE by BLUEROCK Tls UNPACKING THE ITEM Cautin: This machine is packed tgether with items that may be sharp, ily and verly heavy bjects.

More information

TECHNICAL SPECIFICATION. SPC-4T Stirling Process Cryogenerator

TECHNICAL SPECIFICATION. SPC-4T Stirling Process Cryogenerator TECHNICAL SPECIFICATION SPC-4T Stirling Prcess Crygeneratr Reference 80 8044_00 Issue Date April 20, 2016 Stirling Crygenics is a registered trade name f DH Industries BV Fr mre infrmatin n the Stirling

More information

EDBRO RIGID INCLINOMETER

EDBRO RIGID INCLINOMETER EDBRO RIGID INCLINOMETER RINC01 Installatin & Operating Instructins E5542 rev 1 (June 2010) Edbr PLC Nelsn Street, Bltn BL3 2JJ UK Tel: +44 (0) 120 4528888 Fax: +44 (0) 120 4531957 E-mail: pstmaster@edbr.cm

More information

72 Mustang Mach 1 tachometer cluster and gauge conversion

72 Mustang Mach 1 tachometer cluster and gauge conversion 72 Mustang Mach 1 tachmeter cluster and gauge cnversin Dated: 02-17-2009 (drafted by a Chevy persn wrking n his first Frd -nt gd-) The fllwing infrmatin pertains t hw I went abut cnverting the standard

More information

Installation Guide Contigo 6150 & 6151

Installation Guide Contigo 6150 & 6151 Installatin Guide Cntig 6150 & 6151 Cmmercial Vehicle Prductivity and Security The Cntig 6150 & 6151* (cllectively knwn as the Cntig 615X) are highperfrmance beacns designed fr cmmercial prductivity and

More information

WELCOME. WEB LOCATION Los Angeles, CA

WELCOME. WEB   LOCATION Los Angeles, CA WELCOME Thank yu fr chsing AC Infinity. We are cmmitted t prduct quality and friendly custmer service. If yu have any questins r suggestins, please dn t hesitate t cntact us. Visit www.acinfinity.cm and

More information

Delta RPI Commercial Series. Grid-Tied Solar Inverter RPI-M12 / RPI-M15A / RPI-M20A / RPI-M30. The Power Behind Competitiveness.

Delta RPI Commercial Series. Grid-Tied Solar Inverter RPI-M12 / RPI-M15A / RPI-M20A / RPI-M30. The Power Behind Competitiveness. The Pwer Behind Cmpetitiveness Delta RPI Cmmercial Series Grid-Tied Slar Inverter RPI-M12 / RPI-M15A / RPI-M20A / RPI-M30 Prduct Features Transfrmerless Inverter Dual MPP Trackers Peak Efficiency up t

More information

SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA. Appliances. PC TV Light Electricfan

SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA. Appliances. PC TV Light Electricfan SOLAR INVERTER/CHARGER SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA Appliances 420-00300-02 PC TV Light Electricfan Table Of Contents GENERAL PRECAUTIONS... 1 PERSONNEL PRECAUTIONS... 1 INTRODUCTION...

More information

VEHICLE ACTIVATED SPEED LIMIT SIGNS

VEHICLE ACTIVATED SPEED LIMIT SIGNS VEHICLE ACTIVATED SPEED LIMIT SIGNS TRS-VASL VEHICLE ACTIVATED SPEED LIMIT SIGNS Vehicle Activated Speed Limit (VASL) signs measure the speed f appraching vehicles. If the speed f the vehicle is higher

More information

INSTALLATION INSTRUCTIONS FOR PART #47002 WATER / METHANOL INJECTION SYSTEM UNIVERSAL TURBO DIESEL

INSTALLATION INSTRUCTIONS FOR PART #47002 WATER / METHANOL INJECTION SYSTEM UNIVERSAL TURBO DIESEL Kit Cntents INSTALLATION INSTRUCTIONS FOR PART #47002 WATER / METHANOL INJECTION SYSTEM UNIVERSAL TURBO DIESEL Parts UHO Pump (Ultra High Output) 3 Qt Reservir 10 ft High Pressure Tubing 3 ft Black Wire

More information

EnergyCell PLC Series. Owner s Manual

EnergyCell PLC Series. Owner s Manual EnergyCell PLC Series Owner s Manual Abut OutBack Pwer Technlgies OutBack Pwer Technlgies is a leader in advanced energy cnversin technlgy. OutBack prducts include true sine wave inverter/chargers, maximum

More information

ADVISORY: General Motors Upfitter Integration Bulletin #108d P a g e 1 May 18, 2016

ADVISORY: General Motors Upfitter Integration  Bulletin #108d P a g e 1 May 18, 2016 Subject: Aftermarket ALDL r DLC Interface Devices Causing Multiple Issues Mdels All Passenger Cars and Trucks Affected: Mdel Years: 2006 and beynd Date: February 4, 2013 Revisin Date: May 18, 2016 ADVISORY:

More information

FEED SYSTEM ASSEMBLY & OPERATING INSTRUCTIONS

FEED SYSTEM ASSEMBLY & OPERATING INSTRUCTIONS FEED SYSTEM ASSEMBLY & OPERATING INSTRUCTIONS Hg Slat Inc. Newtn Grve, NC USA May 2017 1 Table f Cntents Safety Infrmatin... 4 General Safety Ntes... 5 General Assembly / Operatin Ntes... 6 GROW-DISK Feed

More information

WELCOME. WEB LOCATION Los Angeles, CA

WELCOME. WEB   LOCATION Los Angeles, CA WELCOME Thank yu fr chsing AC Infinity. We are cmmitted t prduct quality and friendly custmer service. If yu have any questins r suggestins, please dn t hesitate t cntact us. Visit www.acinfinity.cm and

More information

INSTALLATION INSTRUCTIONS FOR PART #20001 FORCED INDUCTION BOOST COOLER WATER / METHANOL INJECTION SYSTEMS

INSTALLATION INSTRUCTIONS FOR PART #20001 FORCED INDUCTION BOOST COOLER WATER / METHANOL INJECTION SYSTEMS INSTALLATION INSTRUCTIONS FOR PART #20001 FORCED INDUCTION BOOST COOLER WATER / METHANOL INJECTION SYSTEMS Parts UHO (Ultra High Output) Pump 3 Qt Reservir 10 ft High Pressure Tubing 3ft Wire Lm 18 1/8

More information

MEDMASTER TROFFER Luminaires for MRI/Imaging Suites LED MRIT SERIES

MEDMASTER TROFFER Luminaires for MRI/Imaging Suites LED MRIT SERIES MEDMASTER TROFFER Luminaires fr MRI/Imaging Suites PRODUCT FEATURES: Recessed munt Grid; 2' 2', 2' 4' Nn-ferrus cnstructin safe fr sensitive MRI equipment High-utput, high-cri LED lamp ptins NSF2 rating

More information

General Faucet Installation Instructions

General Faucet Installation Instructions General Faucet Installatin Instructins Step 1: Psitin the Faucet Begin installing yur faucet by placing the gasket and faucet in psitin n the sink. (Diagram A) Frm under the sink, thread the plastic munting

More information

How to Sweat (Solder) Copper Pipe By See Jane DrillTM Copyright 2013, All Rights Reserved

How to Sweat (Solder) Copper Pipe By See Jane DrillTM Copyright 2013, All Rights Reserved Hw t Sweat (Slder) Cpper Pipe By See Jane DrillTM Cpyright 2013, All Rights Reserved Objective T learn hw t attach pieces f cpper pipe by sweating r sldering the metal tgether. This is a helpful skill

More information

JD F Conversion. Combine Manual a

JD F Conversion. Combine Manual a JD 9000-600F Cnversin Cmbine Manual 09040114a Abut Headsight Headsight Cntact Inf Headsight, Inc Bremen, IN 46506 Phne:574-546-5022 Fax: 574-546-5760 Email: inf@headsight.cm Web: www.headsight.cm Technical

More information

Anemómetros digitales portátiles AN-100 extech manual ingles USER MANUAL. Model AN100. CFM/CMM Thermo Anemometer AN100

Anemómetros digitales portátiles AN-100 extech manual ingles   USER MANUAL. Model AN100. CFM/CMM Thermo Anemometer AN100 USER MANUAL CFM/CMM Therm Anemmeter Mdel AN100 CFM/CMM Therm-Anemmeter AN100 Intrductin Cngratulatins n yur purchase f the Extech AN100 CFM/CMM Therm Anemmeter. This instrument measures Air Velcity, Air

More information

DTC P0401 Exhaust Gas Recirculation Flow Insufficient Detected

DTC P0401 Exhaust Gas Recirculation Flow Insufficient Detected DTC P0401 Exhaust Gas Recirculatin Flw Insufficient Detected DESCRIPTION Based n the driving cnditins, the ECM regulates the vlume f exhaust gas that is recirculated t the engine's cmbustin chambers and

More information

INSTALLATION INSTRUCTIONS FOR PART #50015 DIESEL MPG-MAX WATER / METHANOL INJECTION SYSTEM 6.0L/6.4L/6.7L POWERSTROKE DIESEL

INSTALLATION INSTRUCTIONS FOR PART #50015 DIESEL MPG-MAX WATER / METHANOL INJECTION SYSTEM 6.0L/6.4L/6.7L POWERSTROKE DIESEL Kit Cntents INSTALLATION INSTRUCTIONS FOR PART #50015 DIESEL MPG-MAX WATER / METHANOL INJECTION SYSTEM 6.0L/6.4L/6.7L POWERSTROKE DIESEL Parts 7 Galln Reservir UHO Pump (Ultra High Output) 25 ft High Pressure

More information

BPC955 V0 Bliss Powercom Genset Controller. Kirloskar Electric Co. Ltd. User Manual

BPC955 V0 Bliss Powercom Genset Controller. Kirloskar Electric Co. Ltd. User Manual BPC955 V0 Bliss Pwercm Genset Cntrller Kirlskar Electric C. Ltd User Manual This dcument applies t Prduct 9001-0049 Build Versin 3600-0129 Firmware Versin 5000-xxxx The infrmatin cntained in this dcument

More information

MT Pressure Switch INSTALLATION AND OPERATING INSTRUCTIONS. Kaustubha Udyog (Orion Instruments)

MT Pressure Switch INSTALLATION AND OPERATING INSTRUCTIONS. Kaustubha Udyog (Orion Instruments) PRESSURE SWITCHES PRESSURE DIFFERENCE SWITCHES VACUUM SWITCHES Frm 1.5 mbar t 600 bar INSTALLATION AND OPERATING INSTRUCTIONS MT Pressure Switch Cnstructin The pressure switch is hused in a tugh Aluminium

More information

PRE-PLANNING & DELIVERY GUIDE

PRE-PLANNING & DELIVERY GUIDE TM PRE-PLANNING & DELIVERY GUIDE Need Assistance? Call 1-888-329-4847 PRE-DELIVERY Spa Delivery Preparatin Yur spa delivery will arrive CURBSIDE at the specified delivery address yu prvided at the time

More information

INSTRUCTION MANUAL 9500/12000 LBS. D9500SC / D9500SR / D9500SRD D12000SC / D12000SR / D12000SRD MODEL:

INSTRUCTION MANUAL 9500/12000 LBS. D9500SC / D9500SR / D9500SRD D12000SC / D12000SR / D12000SRD MODEL: INSTRUCTION MANUAL 95/ LBS. WINCH MODEL: D95SC / D95SR / D95SRD DSC / DSR / DSRD www.aprveatv.cm 95/ LBS. 95/ LBS. D95SC / DSC D95SR / DSR D95SRD / DSRD As yu read these instructins, yu will see WARNINGS

More information

A L L Diagnostic Trouble Codes ( DTC ): P Code Charts P0302

A L L Diagnostic Trouble Codes ( DTC ): P Code Charts P0302 2012 Chrysler Truck Twn & Cuntry V6-3.6L Cpyright 2013, ALLDATA 10.52 Page 1 A L L Diagnstic Truble Cdes ( DTC ): P Cde Charts P0302 P0302-CYLINDER 2 MISFIRE Special Tls: Fr a cmplete wiring diagram, refer

More information

INSTALLATION INSTRUCTIONS FOR PART #20010 RT1/RT2/DOM WATER / METHANOL INJECTION SYSTEMS

INSTALLATION INSTRUCTIONS FOR PART #20010 RT1/RT2/DOM WATER / METHANOL INJECTION SYSTEMS Kit Cntents INSTALLATION INSTRUCTIONS FOR PART #20010 RT1/RT2/DOM WATER / METHANOL INJECTION SYSTEMS Parts UHO Pump (Special High Output) 3 Qt Reservir 10 Ft High Pressure Tubing 3 Ft Wire Lm 18 1/8 Silicne

More information

Headsight HHC JD xx20 series. Combine Manual

Headsight HHC JD xx20 series. Combine Manual Headsight HHC JD xx20 series Cmbine Manual 09010105 Abut Headsight Headsight Cntact Inf Headsight, Inc Bremen, IN 46506 Phne:574-546-5022 Fax: 574-546-5760 Email: inf@headsight.cm Web: www.headsight.cm

More information

Quark Brushless Systems

Quark Brushless Systems Quark Brushless Systems Instructin Manual fr Quark 22A/33A Universal Versin 2 Speed cntrller needs t be cmpletely checked after a mdel crash. Never use a damaged ESC. The heat sink n the ESC must be used

More information

Gearbox Installation Manual

Gearbox Installation Manual Gearbx Installatin Manual Rtrk Gears HOB/MPR & HOS/MPR ranges (Electrnic cpy available n www.rtrk.cm)! This manual cntains imprtant safety infrmatin. Please ensure it is thrughly read and understd befre

More information

Pre-Planning Delivery Guide

Pre-Planning Delivery Guide Pre-Planning Delivery Guide Need Assistance? Call 1-888-768-6772 Pre-Delivery Spa Delivery Preparatin Yur spa delivery will arrive CURBSIDE at the specified delivery address yu prvided at the time f yur

More information

BUTTON CELL CR2430 BSI M G T E D BRIEF SPECIFICATION

BUTTON CELL CR2430 BSI M G T E D BRIEF SPECIFICATION BUTTON ELL R2430 BSI RE M G IS T E D RE IR F BRIEF SPEIFIATION Mdel: R2430 Nminal Vltage: V Nminal apacity: 270mAh Standard Discharge urrent: 0.4mA Weight: 4.0g Stainless steel cntainer ISO9002 ertified

More information

Instruction Manual. PHscan30 Pocket ph Tester

Instruction Manual. PHscan30 Pocket ph Tester Hazardus Substance Statement Bante is cmmitted t the reductin and eventual eliminatin f all hazardus substances in bth the manufacturing prcess and finished prducts we supply. We have an active manufacturing

More information

Compact Safedrive with built-in Safety Brake. innovative drive systems for industrial doors. Variable Speed Safedrive with built-in Safety Brake

Compact Safedrive with built-in Safety Brake. innovative drive systems for industrial doors. Variable Speed Safedrive with built-in Safety Brake GfA-ELEKTROMATEN Chain Drive Operatr fr Rller Shutter Cmpact Safedrive with built-in Safety Brake Safedrive with built-in Safety Brake Chain Drive with separate Safety Brake Fire Shutter Operatr innvative

More information

TCS and TCS-200-1H Tension Controls

TCS and TCS-200-1H Tension Controls TCS-200-1 and TCS-200-1H Tensin Cntrls P-2003-2-WE 819-0420 Service & Installatin Instructins An Altra Industrial Mtin Cmpany Cntents Intrductin...2 Thery f Operatin...3 Technical Specificatins...3 Installatin

More information

Operator s Manual with Maintenance Information. Second Edition Fourth Printing Part No

Operator s Manual with Maintenance Information. Second Edition Fourth Printing Part No Operatr s Manual with Maintenance Infrmatin Secnd Editin Furth Printing Part N. 48643 Operatr s Manual Secnd Editin Furth Printing Imprtant Read, understand and bey these safety rules and perating instructins

More information

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER CONTENTS ABOUT THIS MANUAL... 1 Purpose... 1 Scope... 1 SAFETY INSTRUCTIONS... 1 INTRODUCTION... 2 Features... 2 Basic System Architecture... 2 Product Overview...

More information

Headsight HHC HH 14 series. Combine Manual

Headsight HHC HH 14 series. Combine Manual Headsight HHC HH 14 series Cmbine Manual 09010204 Abut Headsight Headsight Cntact Inf Headsight, Inc Bremen, IN 46506 Phne:574-546-5022 Fax: 574-546-5760 Email: inf@headsight.cm Web: www.headsight.cm Technical

More information

Rejuvenation Instructions

Rejuvenation Instructions Rejuvenatin Instructins #521 200A Elbws UPR This NRI cvers the fllwing: Hw t prepare 200amp pre-mlded elbws fr injectin. Hw t install and re-infrce an injectin elbw. Hw t size an injectin elbw t match

More information

IQUPS.com Have you checked the IQ of your Power Systems?

IQUPS.com Have you checked the IQ of your Power Systems? IQUPS.cm Have yu checked the IQ f yur Pwer Systems? TMSPDC Transprtable Mdular (Trailer-Mdular Pwer Strage - Offices) Characteristics: Transprtable; Mdular; Simple; Rugged; Military Grade. Systems Designed

More information

USER`s Manual. Swivelling semi-automatic press. Swivelling manual press TECHNICAL DATA. - works without compressor

USER`s Manual. Swivelling semi-automatic press. Swivelling manual press TECHNICAL DATA. - works without compressor USER`s Manual Swivelling semi-autmatic press Swivelling manual press TECHNICAL DATA - wrks withut cmpressr - pens autmatically ( nly Swing S ) - swivels autmatically aside ( nly Swing S ) Dimensins in

More information

OWNER S MANUAL. DCR-205-XX-DC Powered Drum Rotators

OWNER S MANUAL. DCR-205-XX-DC Powered Drum Rotators VESTIL MANUFACTURING CORP. 2999 N. Wayne St., Angla, IN 46703 Ph: 260-665-7586 Fax: 260-665-1339 E-mail: sales@vestil.cm Website: www.vestil.cm 0317 DCR-205-DC, MANUAL DCR-205-XX-DC Pwered Drum Rtatrs

More information

Volume 1.1 OPERATIONAL MANUAL MODEL: CG-30 TRACK TORCH/BURNER MACHINE. by BLUEROCK Tools

Volume 1.1 OPERATIONAL MANUAL MODEL: CG-30 TRACK TORCH/BURNER MACHINE. by BLUEROCK Tools Vlume 1.1 OPERATIONAL MANUAL MODEL: CG-30 TRACK TORCH/BURNER MACHINE by BLUEROCK Tls UNPACKING THE ITEM Cautin: This machine is packed tgether with items that may be sharp, ily and verly heavy bjects.

More information

Effective Date: 10-January Table of Contents

Effective Date: 10-January Table of Contents Versin: 3 Page: 1 f 7 Table f Cntents 1.0 Intrductin... 2 1.1 Purpse... 2 1.2 Scpe... 2 1.3 Definitins... 2 1.4 Training Requirements... 3 2.0 General Requirements... 3 3.0 Inspectin... 3 4.0 Testing...

More information

BioWave Hydro DI-9200 User Manual

BioWave Hydro DI-9200 User Manual BiWave Hydr DI-9200 User Manual Assembling Hydr DI 9200: Assembling yur BiWave Hydr DI 9200, is a very shrt and simple prcess. All yu have t d is take the Hydr DI 9200 ut f the bx, make sure its standing

More information

Mag-Nus2 MAGNETIC, SELF CLEANING, DIRT SEPARATOR

Mag-Nus2 MAGNETIC, SELF CLEANING, DIRT SEPARATOR Mag-Nus2 MAGNETIC, SELF CLEANING, DIRT SEPARATOR CT3548.0_00 EN Octber 2017 Retains all impurities Self-cleaning Excellent hydraulic prperties Can be munted n vertical, hrizntal and diagnal piping Increases

More information

EDBRO TRAILER INCLINOMETER

EDBRO TRAILER INCLINOMETER EDBRO TRAILER INCLINOMETER TINC01 (12V AND 24V VERSIONS) Installatin & Operating Instructins E5541 rev 5 (Sept 2015) Edbr PLC Nelsn Street, Bltn BL3 2JJ UK Tel: +44 (0) 120 4528888 Fax: +44 (0) 120 4531957

More information

Installation, Operation & Maintenance Manual. SunWize Power & Battery Power Ready System

Installation, Operation & Maintenance Manual. SunWize Power & Battery Power Ready System Installatin, Operatin & Maintenance Manual SunWize Pwer & Battery Pwer Ready System Manual # PM296038 www.sunwizepwer.cm Table f Cntents 1 INTRODUCTION TO SUNWIZE POWER & BATTERY POWER READY SYSTEMS...

More information

Lithium Battery Shipping Overview

Lithium Battery Shipping Overview Lithium batteries are used in many electrnic devices such as cameras, cell phnes, laptp cmputers, medical equipment and pwer tls. When shipping r imprting lithium batteries, including thse cntained in

More information

Safety Rules. Danger Failure to obey the instructions and safety rules in this manual will result in death or serious injury. Do Not Operate Unless:

Safety Rules. Danger Failure to obey the instructions and safety rules in this manual will result in death or serious injury. Do Not Operate Unless: Third Editin First Printing Operatr's Manual Safety Rules Danger Failure t bey the instructins and safety rules in this manual will result in death r serius injury. D Nt Operate Unless: Yu learn and practice

More information

Open Street Cam User Manual

Open Street Cam User Manual Open Street Cam User Manual Table f cntent 1.Installing the app and setting it up fr the first time 1.1 Installing the app 1.2 Setting up the app fr the first time 2. Installing the smartphne in the car

More information

UPS. Uninterruptible Power Supply MKD 700 / 1000 XL. Manual ACX11MKS1K0000XL

UPS. Uninterruptible Power Supply MKD 700 / 1000 XL. Manual ACX11MKS1K0000XL UPS Uninterruptible Pwer Supply MKD 700 / 1000 XL Item number: ACX11MKS700000XL ACX11MKS1K0000XL Versin V1.1 May 2010 Cntent 1 Presentatin 4 2 Warranty cnditins 5 2.1 Limitatin f liability 6 3 Safety 7

More information

Refer to the description for DTC P0C Refer to DESCRIPTION.

Refer to the description for DTC P0C Refer to DESCRIPTION. Print 203 Tyta Prius 8L Eng Plug-In P34A REQUESTED INFORMATION Dtc P34A-828: Inverter Clant Pump Speed Signal Descriptin Refer t the descriptin fr DTC P0C73-776 Refer t DESCRIPTION The inverter water pump

More information

VALVE-REGULATED SEALED LEAD ACID BATTERY. FMJ GEL Series. High Performance. Product Guide

VALVE-REGULATED SEALED LEAD ACID BATTERY. FMJ GEL Series. High Performance. Product Guide VALVE-REGULATED SEALED LEAD ACID BATTERY FMJ GEL Series High Perfrmance Prduct Guide Cntents Intrductin...01 Technical Features...01 Applicatins...02 Certificatin...02 Standards...02 General Specificatins...02

More information

Instruction Manual. Scrubmaster B30 / B30 CL (7715)

Instruction Manual. Scrubmaster B30 / B30 CL (7715) Instructin Manual Scrubmaster B30 / B30 CL (7715) Intrductin Preface Dear custmer, It is ur desire that the gd characteristics f the Scrubmaster B30 shuld justify the cnfidence yu demnstrated by making

More information

Operator s Manual with Maintenance Information. First Edition Eleventh Printing Part No

Operator s Manual with Maintenance Information. First Edition Eleventh Printing Part No Operatr s Manual with Maintenance Infrmatin First Editin Eleventh Printing Part N. 39527 Operatr's Manual First Editin Eleventh Printing Imprtant Read, understand and bey these safety rules and perating

More information

Operation & Maintenance Manual For Commercial Use Only

Operation & Maintenance Manual For Commercial Use Only Operatin & Maintenance Manual Fr Cmmercial Use Only SWB 26/8 Battery Sweeper 2 Table f cntent 1 Safety infrmatin... 4 1.1 Safety and Warning Symbls... 4 1.2 General infrmatin... 4 1.3 Operating infrmatin...

More information

Mini H1 Twin Kit - Installation Instructions

Mini H1 Twin Kit - Installation Instructions Intrductin: Thanks fr purchasing the Mini H twin kit! Yu are very clse t imprve yur lightning nw :) Please read this manual carefully. Feel free t cntact us r visit ur Facebk cmmunity; Eurpean Headlight

More information

Advanced 3 Million Wireless USB Limousine Underbody Kit

Advanced 3 Million Wireless USB Limousine Underbody Kit Advanced 3 Millin Wireless USB Limusine Underbdy Kit Warning: Please check yur state and lcal laws befre installing this LED underbdy kit. Every state has different plicies and prcedures in place regarding

More information

Self Consumption in residential systems

Self Consumption in residential systems Self Cnsumptin in residential systems Brad Bassett Sr. Applicatin Engineer Jan 27, 2017 San Dieg, CA What is Self Cnsumptin? A direct grid tie system is where slar energy prduced, pwers the huse lads as

More information

EasyPower User Manual

EasyPower User Manual www.alelin.cm EasyPwer User Manual EP48460CWT-CB4-E (1003220) EP48460CWT-CB3-E (1003500) EP48310CWT-CB3-E (1003200) Cntents General... 3 Safety... 4 Overview... 5 Operatin... 7 Trubleshting... 10 Recycling...

More information

BIG-VUE Series Meter

BIG-VUE Series Meter USA SINCE 1936 RELIABILITY BEYOND MEASURE Technical Data Sheet BIG-VUE Series Meter File N. E471457 LAC DU FLAMBEAU,WI LAC DU FLAMBEAU,WI 1/2 The mving irn & mving cil panel meters sizes 2 " 1/2, 3 " are

More information

You have a Chiller, Now What?

You have a Chiller, Now What? Yu have a Chiller, Nw What? Raschell Hickmtt Reginal Sales Manger Dimplex Thermal Slutins Klant Klers Brand Chillers Agenda This presentatin is develped t be a very brief and generic intrductin t anyne

More information

Appointment Plus User Instructions

Appointment Plus User Instructions Appintment Plus User Instructins This dcument prvides the user with instructins fr the Appintment Plus System. Appintment Plus System Features This is a tl fr managing the fllwing: Technician Wrk Frce

More information

GLOBAL LIFT CORP. Owner s Manual. Rotational Series R-375

GLOBAL LIFT CORP. Owner s Manual. Rotational Series R-375 GLOBAL LIFT CORP Owner s Manual Rtatinal Series R-375 684 N Prt Crescent Rd Suite C Bad Axe, MI 48413 Tll Free: 866-712-0606 Fax: 989-269-5902 www.glballiftcrp.cm Page 1 ROTATIONAL SERIES POOL LIFTS R-375

More information

Audi 8L A3 and B5 A4 ColorMFA Install Guide ColorMFA from AutoPilot. Instructions from Clusters by Litke and pinout from Drive2

Audi 8L A3 and B5 A4 ColorMFA Install Guide ColorMFA from AutoPilot. Instructions from Clusters by Litke and pinout from Drive2 Audi 8L A3 and B5 A4 ClrMFA Install Guide ClrMFA frm AutPilt. Instructins frm Clusters by Litke and pinut frm Drive2 This is an verview guide n hw t install the v3.2/v3.4 ClrMFA units int Audi 8L and B5

More information

PV-70 Remotely Operated Cryogenic Globe Valve Installation, Operation, and Maintenance Manual

PV-70 Remotely Operated Cryogenic Globe Valve Installation, Operation, and Maintenance Manual PV-70 Remtely Operated Crygenic Glbe Valve Installatin, Operatin, and NOTIC: Printed cpies are uncntrlled. Page 1 f 12 TABL OF CONTNTS 1. INSTALLATION... 2 2. OPRATION... 4 3. MAINTNANC... 4 4. PRSSUR

More information