Safety Protection. Catalogue 2013/2014 Contactor & Overload Relay MAXTRIC. circuit breaker.

Size: px
Start display at page:

Download "Safety Protection. Catalogue 2013/2014 Contactor & Overload Relay MAXTRIC. circuit breaker."

Transcription

1 Safety Protection Catalogue 03/0 Contactor & Overload Relay MAXTRIC circuit breaker Working with the world s electric specialist

2 AC Contactor series AC Contactors, 3P AC Contactors, 3P AC Contactor, 3P Contactor & Relay Contents CJXN series (New model) CJXD series (Old model) CJXF series AC Contactors, P/P DC Contactors Reversing Contactors CJXD series CJXZ series CJXN series Capacitor switching contactors AC Contactors AC Contactors CJ series CJX series CJX5 series

3 Contents Mini Contactor series Mini Contactors Mini Contactors CJXK series CJXE series Thermal Overload Relay series Thermal Overload Relay Thermal Overload Relay Thermal Overload Relay JRSD series Starter series Magnetic starters JRS series Magnetic starters JRS5 series Stardelta starters QCX series QCX5 series LC3D series 3

4 AC CONTACTOR CJX(NEW) CJXN series AC contactors are suitable for frequency 50/60Hz,rated insulation voltage up to 000V,rated operation current ~50A under AC3 duty. It is mainly used for breaking electric circuits at a long distance and for frequent starting, stopping & controlling AC Motors. It is used in combination with thermal relay to compose a magnetic motor starter. The products comply with IEC607. Type Ref. CJXN0 CJXN CJXN8 CJXN5 CJXN3 Rated Operational Current Ie max AC3(000V) A 5A A A 0A Ie max AC3(30V) A A 8A 5A 3A Ie max AC3(5000V) 7A A A 8A A Rated Power KW/HP (AC3) 00V0V A A 8A 5A 3A 3V0V A A 8A 5A 3A 500V0V A A 8A 5A 3A Rated heating current Ith 8A 8A 5A 0A 0A Rated Insulated Voltage Ui V V V V V Contact arrangement NO+NC Rated current (AC3) 00V0V.6A 30V 0.5A Rated heating current Ith: 6A

5 CJXN0 CJX50 CJX65 CJXN CJXN5 CJXN5 CJXN50 50A 60A 75A 0A 0A 5A 60A 0A 50A 65A A 5A 5A 50A 3A 3A A 50A 65A 85A 0A 0A 50A 65A A 5A 5A 50A 0A 50A 65A A 5A 5A 50A 0A 50A 65A A 5A 5A 50A 60A A A 0A A 5A 60A V V V V V V V 5

6 AC Contactors CJXD (Old Model) Contactor & Relay APPLICATION CJX series AC contacor is used for longdistance making and breaking in circuit with frepuency 50Hz or 60Hz, rated voltage to V and rated current up to 60A. The item, in combination with thermal relay, protects circuit against overload as electriomagnetic starter, It also functions as delaytype, reversible contactor and stardelta starter when combined with auxiliary contact group, air delayer and mechanical interlocking device. CJXD0 Standard power ratings of 3phase motors Rated operating current 50/60 Hz in category AC3 AC3 AC 0V 3V V up to Ø 0 o C V 00V 5V 0V 500V V 0V KW KW KW KW KW KW A A. 5 Instantaneous auxiliary contacts Basic reference Complete with code indicating control circuit voltage Fixing CJX00 CJX00 CJXD3 3 5 CJX0 CJX CJX CJX CJX50 CJX CJX30 CJX30 CJXD CJX CJX CJX CJX CJX CJX CJX50 CJX70 CJXD CJX CJX CJX CJX CJX CJX60 CJXD5 6

7 AC Contactors CJXF Standard power ratings of 3phase motors Rated operating current 50/60 Hz in category AC3 AC3 AC 0V 3V V up to Ø 0 o C V 00V 5V 0V 500V V 0V KW KW KW KW KW KW A A Instantaneous auxiliary contacts Basic reference Complete with code indicating control circuit voltage Fixing CJXF5 CJXF50 CJXF85 CJXF5 CJXF65 CJXF3 CJXF00 CJXF500 CJXF CJXF7 AC Contactors CJXD & Pole Noninductive loads maximum current (<=0 o C) utilisation category AC A Number of poles Basic reference Complete with code indicating control circuit voltage 5 CJX00 CJX CJX008 CJX500 CJX CJX000 CJX0008 CJX6500 CJX CJX00 CJX00 CJX

8 DC Contactors CJXZ Standard power ratings of 3phase motors Rated operating current 50/60 Hz in category AC3 AC3 AC 0 V <=0 o C 0V 3V V up to V 00V 5V 0V 500V V KW KW KW KW KW KW A A. 5 Instantaneous auxiliary contacts Basic reference Complete with code indicating control circuit voltage Fixing CJX00Z CJX00Z CJX0Z CJX0Z CJXZ CJXZ CJX CJX50Z CJX50Z CJX30Z CJX30Z CJX0Z CJX50Z CJX65Z CJX CJXZ Reversing contactors CJXN Standard power ratings Rated Max. of 3phase motors operating rated current operating 50/60 Hz in category AC3 cat. voltage AC3 0V 3V V up to V 00V 5V 0V 500V V 0V KW KW KW KW KW KW A V No. of instantaneous auxiliary contacts per concator Contactors supplied with coil Basic reference. Complete with code indicating control circuit voltage Fixing Connectio. CJXN00 3 CJXN CJXN CJXN CJXN CJXN CJXN CJXN CJXN CJXN CJXN CJXN5 8

9 Capacitor switching Contactors CJ Operating power at 50/60 Hz 0 o C() 0 o C() Instantaneous auxiliary contacts 0V 00V 0V 00V 0V 0V 0V 0V KVAR KVAR KVAR KVAR N/O N/C Basic reference Complete with code indicating control circuit voltage() CJDFK CJDFK CJDGK CJDGK CJDLK CJDLK CJDMK CJDMK CJDPK CJDTK CJDWK FD Auxiliary contact blocks References F F0 F0 F F3 F3 F0 F0 Contact number N/O+N/C N/C N/O N/O+N/C 3N/O+N/C N/O+3N/C N/O N/C F5 Time delay auxiliary contact blocks References Contact number Delay type Range F5DT0 N/0+N/C OFFDELAY 0. to 3s F5DT N/0+N/C ONDELAY 0. to s F5DT N/0+N/C OFFDELAY 0 to s F5DR0 N/0+N/C OFFDELAY 0. to 3s F5DR N/0+N/C OFFDELAY 0. to s F5DR N/0+N/C OFFDELAY 0 to s

10 AC Contactors CJXF TYPE Rated operating Current AC3V Rated voltage Standard power ratings of 3phase motors 0V 3V 500V V V 00V (A) (V) KW KW KW KW CJXF. CJXF 3.3 CJXF6 6 0 CJXF 6. CJXF70 CJXF CJXF CJXF CJXF CJXF CJXF CJXF CJXF0 CJXF CJXF CJXF CJXF CJXF CJXF CJXF63 CJXF CJXF CJXF6 CJXF3 0

11 AC Contactors CJX5 Type Rated operating Current AC3V Rated voltage AC3 Standard power ratings of 3phase motors 0V 3V 500V V V 00V (A) (V) KW KW KW KW CJX5K0 CJX5N0.5 CJX5K CJX5K CJX5N CJX5K CJX5N CJX5K0 CJX5N0 CJX5K CJX5N CJX5K5 CJX5N5 5 5 CJX5K35 CJX5K35 CJX5N CJX5K50 CJX5N CJX5K65 CJX5N CJX5K CJX5N CJX5K5 CJX5N5 05 CJX5K CJX5K65 CJX5K0 CJX5K5 CJX5N5 CJX5N65 CJX5N CJX5N0

12 Cat. No. CJXK CJXK series AC contactor is suitable for use in the circuit up to the rate and frequentstarting, controlling the AC motor. The addition of auxiliary contact group to the contactor, combined with the proper thermal relay, can act to protect the circuit bound to overload. It conformsto IEC607. Data: Contactor & Relay Cat. No. CJXK06 CJXK0 CJXK Rated operational AC3 6 3V current AC Rated Insualtion Voltage (V) Rated Heating current (A) V.5. 3 Rated operational power in AC3 3V. V 3 AC Operational Electric life AC frequency Mechnical life Electric life (*0 ) AC AC Mechnical life (*0 ) Ref. No. FK0, K0, K, K3, K3, K0, K0 Auxiliary contacts Rated heating current 6A 6A 6A Capacity AC5 360VA, DC3 33W Compatible fuse Dimensions: CJXK0 CJXK0N RT66 CJX K06~K CJX K06N~KN

13 Cat. No. CJXE CJXE series AC contactor is suitable for use in the circuit up to the rate and frequentstarting, controlling the AC motor. The addition of auxiliary contact group to the contactor, combined with the proper thermal relay, can act to protect the circuit bound to overload. It conformsto IEC607. Data: Cat. No. CJXE06 CJXE0 Rated operational current 3V AC3 6 AC Rated Insualtion Voltage (V) Rated Heating current (A) 6 6 0V.5. Rated operational power in AC3 3V. V 3 AC Electric life Operational frequency AC 0 0 Mechnical life Electric life (*0 ) AC AC 0 0 Mechnical life (*0 ) Ref. No. FE0, E0, K, E Auxiliary contacts Rated heating current 6A 6A Capacity AC5 360VA, DC3 33W Compatible fuse Dimensions: CJXE0 CJXE0N RT66 CJX E06~K0 CJX E06N~E0N 3

14 Thermal overload relays JRS JRSD3 JRSD33 Type Setting current range (A) Plug in contactor Type Setting current range (A) Plug in contactor JRSD JRSD JRSD3 JRSD JRSD5 JRSD6 JRSD3X6 JRSD7 JRSD8 JRSD JRSD3 JRSD3 JRSD36 JRSD3 JRSD353 JRSD3 JRSD3 JRSD33 JRSD3353 JRSD33 0.~ ~ ~ ~ ~ ~.6.5~.6~.5.5~ ~6 ~8 7~0 ~3 ~8 3~3 8~36 7~5 7~5 3~3 ~0 CJXD0~D3 CJXD0~D3 CJXD0~D3 CJXD0~D3 CJXD0~D3 CJXD0~D3 CJXD0~D3 CJXD0~D3 CJXD0~D3 CJXD0~D3 CJXD0~D3 CJXD0~D3 CJXD~D3 CJXD8~D3 CJXD5~D3 CJXD3 CJXD5~D3 CJXD0~D5 CJXD0~D5 CJXD0~D5 JRSD0 JRSD0 JRSD03 JRSD0 JRSD05 JRSD06 JRSD07 JRSD08 JRSD0 JRSD03 JRSD03 JRSD036 JRSD63 JRSD53 JRSD0353 JRSD03 JRSD63357 JRSD6335 JRSD6336 JRSD ~ ~ ~ ~ ~ ~.6.6~.5.5~ ~6 ~8 7~0 0~3 3~8 ~5 3~3 ~0 38~50 8~57 57~66 63 CJXD0~5 CJXD0~5 CJXD0~5 CJXD0~5 CJXD0~5 CJXD0~5 CJXD0~5 CJXD0~5 CJXD0~5 CJXD0~5 CJXD0~5 CJXD0~5 CJXD0~5 CJXD0~5 CJXD CJXD CJXD CJXD CJXD CJXD JRSD3357 ~50 CJXD50~D5 JRSD335 8~65 CJXD50~D5 JRSD336 ~70 CJXD65~D5 JRSD ~ CJXD~D5 JRSD3365 ~3 CJXD5

15 5 Contactor & Relay Thermal overload relays JRS Type Setting current range A Suitable Contactors 0A 0C 0E 0G 0J 0K A B C D E F G H J K S 0A 0C 0E 0G 0J 0K A B C D E F G H J K A B C G J A B C D Q 0A 0C 0E 0G 0J 0K A B C D E F G H J K A B C D Q R 8M TB0 3TF0 3TB 3TF 3TF 3TF3 CJXF CJXF 3TB 3TF 3TB3 3TF3 3TF3 3TF33 CJXF6 CJXF 3TF CJXF3 3TF 3TF5 3TF3 3TF35 CJXF3 CJXF38 Type Setting current range A Suitable Contactors TF0 3TB0 3TF 3TB 3TF 3TB 3TF3 3TB3 3TF 3TB 3TF5 3TF6 3TF7 3TF8 CJXF CJXF CJXF6 CJXF CJXF3 CJXF38 CJXF5 CJXF63 CJXF75 3TF6 3TF7 3TF8 CJXF5 CJXF63 CJXF75 3TF50 3TF5 3TF5 CJXF0 CJXF0 CJXF70 3TF5 3TF CJXF50 CJXF0 0A 0C 0E 0G 0J 0K 0A B C D E F G H J K A B C D E M T P G 8A B C D E F T P V U 8W H W X 3H 3J 3K 3L 3M K 3B 3C 3D 3E 3F 3G JRS.5/Z JRS5/Z JRS3/Z JRS5/Z JRS63/Z JRS/Z JRS/F JRS00 JRS6

16 Contactor & Relay 6 Thermal overload relays T Setting current range A Thermal overload relays JRS5 Setting current range A T6 T5 T5 T85 T05 T70 T50 T0 JRS5/Z JRS50/F JRS560/F

17 Magnetic starters QCX QCXD0~D8 Specification:. Rated volage: V;. Frequency: 50Hz/60Hz; 3. Temperature: 5 C~+0 C;. Protection degree: IP65; Data: Cat. No. Rated Current (A) 3V Rated heating current (A) Motor Capacity (kw) AC3 Av. Capacity VA (0 C)50Hz AC3 AC 0V 3V V Contact Keeping QCX QCX QCX QCX QCX QCX QCX QCX QCX QCX Weight (kg) QCXD5~D3 QCXD5~D3 QCXD0~D5 QCXD0~D5 7

18 Magnetic starters QCX5 QCX5K0PM/KPM QCX5K0PM/KPM QCX5K5PM/K35PM Stardelta starter LC3D 8

19 Soft starters The traditional method of squirrelcage asynchronous motor:y starting and autotrans former starting. But each bas its fault.the former will appear high current point during the changeover time and produce destructive dynamic torque. Its mechanical vibration is harmful to the electrical rotor, ascial connection, middle gear and load. The latter has the feature of large volumn and high maintenance rate.it is also difficult to control electrical torque which is adapted to the load. Owing to the weakness of these two starting methods, soft starting is widely used by more and more customers. The teature of low start current, energysaving and the protection functions of motor improve the production efficiency. It is an ideal renewal product to substitute the traditional starter. Operation conditions () Power:threephase 3V±5% 50Hz () Motor:threephase AC asychronous motor (3) Environmental Temp: 0 0 () Relative humidity: Max 0% (Temp 0 ) (5) Start frequency: less than 5 times per hour (6) Specification: JJRSkw7kw JJRSkw JJRSkw JJRSkw JJRS5kw JJRSkw JJRS75kw JJRS0kw JJRS5kw JJRS3kw JJRS60kw JJRS00kw JJRS50kw JJRS30kw JJRS00kw JJRS500kw

CJX2N Series AC Contactor

CJX2N Series AC Contactor AC Contactor 18 page 1 page 1 page 131 page 13 page 13 page 133 page 13 page 135 page 136 page 136 page 137 page 138 CJXN CJXN CJXD LA1D Series Contactor Blocks LAD Series Contactor Blocks LC1F Bobbin

More information

ELECTRIC PRODUCT CATALOGUE

ELECTRIC PRODUCT CATALOGUE ELECTRIC PRODUCT CATALOGUE!"#$%&' www.cetelec.com.cn SHANGHAI CET ELECTRIC CO. LTD. is one of the leading and the most reliable manufacturers and exporters for low voltage and high voltage electric products

More information

Essential equipment for all your requirements

Essential equipment for all your requirements NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides

More information

Ktec Contactors and thermal overloads

Ktec Contactors and thermal overloads Contactors and thermal overloads Techna KTEC series contactors provide a complete solution for your ac contactor requirements.the range carries TUV, UL & CSA certification, for use in Europe, North America

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

Motor Starting Solutions Open Type Version, in Kit Form

Motor Starting Solutions Open Type Version, in Kit Form Motor Starting Solutions Open Version, in Kit Form Starters Protected by Manual Motor Starters Direct-On-Line Starters I> Reversing Starters I> MS... Manual motor starter MS... Manual motor starter BEA...

More information

Low voltage switch gear

Low voltage switch gear Low voltage switch gear Omron is an established global manufacturer of low voltage switch gear (LVSG) products, and the company s new series (J7) complements the existing portfolio. High power-handling

More information

About us. Switchgear Factory, Mumbai

About us. Switchgear Factory, Mumbai About us Larsen & Toubro is a technologydriven USD 8.5 billion company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field of Engineering, Construction,

More information

AF09... AF38 3-pole contactors 4 to 18.5 kw, AC / DC operated

AF09... AF38 3-pole contactors 4 to 18.5 kw, AC / DC operated AF09... AF3 3-pole contactors 4 to 1.5 kw, AC / DC operated AF09-30-10 AF09... AF3 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and 220 V DC. These contactors

More information

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101412D0201 25/03/11-30-00-.. / Z-30-00-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101408D0201 25/03/11-30-01-.. / Z-30-01-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101415D0201 25/03/11 AF30-30-11-.. / AF30Z-30-11-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF30(Z) contactors are used for controlling power circuits

More information

EW series Industrial contactors

EW series Industrial contactors 2012_EW_Contactors_bro_EN.qxd:Mise en page 1 31/08/12 10:24 Page 2 EW series Industrial contactors Hager offers a complete range of contactors for commercial market such as buildings, infrastructures,

More information

ASL09..S 3-pole Contactors - Spring Terminals

ASL09..S 3-pole Contactors - Spring Terminals 4 kw 5 hp ASL09..S 3-pole Contactors - Spring DC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Low coil consumption, - Polarity on the coil

More information

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors...

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors... Three-pole versions up to 630A in IEC AC3 duty Four-pole versions up to 1600A in IEC AC1 duty Versions for power factor correction up to 100kvar at 400VAC Four-pole versions with NO+NC or 4NC main poles

More information

6300A 15 Optibreak B1 & B2 Optibreak B1 & B2 50/60 Hz Ue Icu [v] [ka] 415 65 690 40 4h 4i 1. Open / close Indication 2. Charge and Discharge Indicator 3. Release the reset button 4. Laser Nameplate

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

Page 2-4 Page 2-8. Page Page 2-13

Page 2-4 Page 2-8. Page Page 2-13 Page -4 Page -8 THREE-POLE CONTACTORS IEC Ith ratings in AC1 duty at 40 C: 16 to 1600A IEC Ie ratings in AC3 440V duty: 6 to 630A IEC Power ratings in AC3 400V duty:. to 335kW UL/CSA ratings: 3 to 500HP

More information

22AF 40AF AF 150AF 225AF 400AF 800AF

22AF 40AF AF 150AF 225AF 400AF 800AF Contactors MC-Series UL508 E108780 Contactor 3 Pole Standards and Certifications UL508 IEC 60947-2 & IEC 60947-4-2 CSA C22.2 No.14 Features 8 Frame Sizes 1/2HP up to 600HP @ 480V AC Screw Terminals (Lug

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

3RT14 Contactors with 3 Main Contacts

3RT14 Contactors with 3 Main Contacts 3RT14 Contactors with 3 Main Contacts for Switching Resistive Loads Contactor Size 3RT14 46 Mechanical endurance Oper. 10 million Electrical endurance Oper. 0.5 million C-1 utilization category at I e

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet SBC042D020 06/04/ -22-00-.. / Z-22-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440 V DC.

More information

SIRIUS Innovations. Technical information for ring terminals SIRIUS. Answers for industry.

SIRIUS Innovations. Technical information for ring terminals SIRIUS. Answers for industry. SIRIUS Innovations. Technical information for ring terminals SIRIUS Answers for industry. Order data Assembly up to 7.5 kw (S00) fused assembly 2 Motor Starter (Fuses, Contactor, Overload Relay) Contactor

More information

TAE pole Contactors

TAE pole Contactors TAE9...26 3-pole Contactors d.c. operated with double-winding coil SB8033C3 Utilisation TAE9 to TAE26 contactors are a compliment to the DC control contactor range. The coils have large voltage ranges

More information

CI-TI Contactors and motor starters Types CI 61 - CI 98

CI-TI Contactors and motor starters Types CI 61 - CI 98 Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include

More information

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France Contact us ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F-69687 Chassieu cedex / France You can find the address of your local sales organisation on

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101419D0201 06/04/11-40-00-.. / Z-40-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440

More information

cor Long Run Experience

cor Long Run Experience Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30

More information

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals NSL..S 4-pole / 8-pole Contactor Relays - Spring DC Operated Description - 1-stack contactor relays: 4-pole, - 2-stack contactor relays: 8-pole, - Mechanically linked contact elements available, - Low

More information

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries Safety Relay Unit Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries Two-pole slim models that are only 22.5 mm wide, three-pole models that are only 68 mm wide,

More information

Switches Unlimited Phone: * Fax:

Switches Unlimited Phone: * Fax: For Info: sales@switchesunlimited.com www.switchesunlimited.com Phone: 800-1-0487 Fax: 718-67-6370 Page -4 Page -8 THREE-POLE CONTACTORS IEC Ith ratings in AC1 duty at 40 C: 16 to 1600A IEC Ie ratings

More information

Bulletin 190-M Compact Starters. Selection Guide

Bulletin 190-M Compact Starters. Selection Guide Bulletin 190-M Selection Guide Bulletin 190-M Selection Guide 3 Bulletin 190-M Compact Design to 45mm Wide Common Adapter for Panel or DIN Rail Mounting Pre-Wired Assembly All Control Terminations Located

More information

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX IEC-Contactor RSC 1 Features Rated operational current 9 63 (C-3) Coil voltages C 24, 230V 3 main contacts and auxiliary contact Extendable with auxiliary contact block Mounting position any 2 Description

More information

Training & Didactic Systems. Fundamentals of Electrical Engineering

Training & Didactic Systems. Fundamentals of Electrical Engineering Training & Didactic Systems Fundamentals of Electrical Engineering Catalog WA1E/01 Table of Contents Page Our Service, Our Customers and fields of technology 2 Introduction 4 Instruction modules measuring

More information

MAGNETIC CONTACTOR & MOTOR STARTER

MAGNETIC CONTACTOR & MOTOR STARTER http://www.seec.com.tw http://circuit-breaker.seec.com.tw MAGNETIC CONTACTOR & MOTOR STARTER P Functionalities and characteristics of Magnetic Contactor Configuration Composite magnetic switch (abbreviated

More information

Industrial Contactors CTX 3 3P 185A - 800A

Industrial Contactors CTX 3 3P 185A - 800A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...

More information

MAGNETIC CONTACTOR & MOTOR STARTER

MAGNETIC CONTACTOR & MOTOR STARTER http://www.seec.com.tw http://circuit-breaker.seec.com.tw MAGNETIC CONTACTOR & MOTOR STARTER P Functionalities and characteristics of Magnetic Contactor Configuration Composite magnetic switch (abbreviated

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload According to CE, IEC 947, EN 60947 Contactor Catalogue 3 Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload Mini-Contactors 4kW - 5.5kW DC Contactors Mini-Relays 10A Motor Starter DOL, Star-Delta Capacitor

More information

THREE-POLE CONTACTORS series HR09-HR13 up to 6 kw

THREE-POLE CONTACTORS series HR09-HR13 up to 6 kw THREE-POLE CONTACTORS series HR09-HR3 up 6 kw USE Series HR contacrs are particularly suitable for controlling mors, heating elements and three-phase and single-phase loads in general. OPERATION AND INSTALLATION

More information

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 CTX 3 Control relays Cat. N (s) : 4 168 00..04/06/09..14/16/19..24/26/29 CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3.

More information

C -5 to +55 (0.8 to 1.1Uc) Permissible o

C -5 to +55 (0.8 to 1.1Uc) Permissible o T - Line Contactors 3 & 4 Pole Contactors with C operating coils General Characteristics Type Unit TC1-D09 ~ TC1-D95 Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 VDEO 110grC/IEC 60947-4

More information

Contactors : Wide band AC / DC operated

Contactors : Wide band AC / DC operated Contactors : Wide band AC / DC operated NF / s Wide band AC / DC Operated - with Screw Terminals Description NF / include an electronic coil interface accepting a wide control voltage Uc min.... Uc max.

More information

SWITCHGEAR. 4G cam switches

SWITCHGEAR. 4G cam switches SWITCHGEAR 178 4G cam switches ENERGY SAFELY SWITCHED 179 SWITCHGEAR 180 GENERAL INFORMATION 4G-series cam switches are low voltage switches, designed according to the latest knowledge about switchgear

More information

COMPLETE SOLUTIONS FOR POWER PROTECTION

COMPLETE SOLUTIONS FOR POWER PROTECTION COMPLETE SOLUTIONS FOR POWER PROTECTION GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES Modular protection P. 8 RX 3 MCBs 63 A 4500 & 6000 P. 18 DX 3 -IS isolating switches P. 9 RX

More information

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD Bulletin Product Selection Open Type and Non-Combination Enclosed (IP, NEMA /) Controllers For use with Line-Connected Motors Rated Voltage [V AC] / Motor Current [A]...... Max. kw, Hz Max. Hp, Hz Control

More information

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1 Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175.

1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175. SIRIUS 3RT0 3-Pole with AC Coil 3RT0* through 3RT04* 4-point AC coil can be wired on top, bottom, or diagonally. Direct mount 3RU or 3RB0 solid state overload relays to create starters. Snap-on auxiliary

More information

AE 9... AE 40 Contactors NE... Contactor Relays

AE 9... AE 40 Contactors NE... Contactor Relays Technical data AE 9... AE 0 Contactors NE... Contactor Relays AE 9... AE 0 Contactors NE.. Contactor Relays Contents AE 9... AE 0 Contactors Description... 2 Ordering Details... 3 Technical Data... Terminal

More information

SINCE 1989 Quality Products, Prompt Services, Trustful Relationships wwwkmindustrialcorpcom KM Industrial Corporation has established itself as a trusted supplier of Electrical, Machinery and Industry

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

Low Voltage. EasyPact TVS. Motor starters from 6A to 630A. Catalog 2015

Low Voltage. EasyPact TVS. Motor starters from 6A to 630A. Catalog 2015 Low Voltage EasyPact TVS Motor starters from 6A to 630A Catalog 2015 Designed for the essential EasyPact TVS General contents EasyPact TVS contactors, 6 A to 630 A A-1 EasyPact TVS thermal overload relays

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

Technical Information

Technical Information -100 Controller IEC Performance Data (CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device Catalog No. -100... 25A 40A 63A 90A Maximum Short-Circuit Current 480V [ka] 65 65 42

More information

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires

More information

Features. Applications. Commercial Industrial Mining. New CBI range additional to existing range DILM7 SN10 DILM9 SN11 DILM12

Features. Applications. Commercial Industrial Mining. New CBI range additional to existing range DILM7 SN10 DILM9 SN11 DILM12 GLOBAL RANGE Global Range Thermal Contactors Contactors Contactor Product Comparison Features Competitively priced Comprehensive range (AC & DC) Fitted with Auxiliary/s as standard Type coordination Applications

More information

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB6, VB7 -pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB7-0-10 2CDC211006F0011 Description VB6, VB7 -pole compact design reversing contactors are space optimized control

More information

Capacitor Switching Contactors Type K3...-A, K3...-K

Capacitor Switching Contactors Type K3...-A, K3...-K Type K3...-A, K3...-K Features that matter: Patented design with significant damping on inrush-current Long-life contactors tested by FRAKO up to 100,000 switching operations Suitable for unchoked and

More information

Short form catalogue Motor protection and control Block contactors and overload relays

Short form catalogue Motor protection and control Block contactors and overload relays Short form catalogue Motor protection and control Block contactors and overload relays Motor rated operational powers and currents The currents given below concern standard three-phase four-pole cage motors

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30 Characteristics TeSys contactors Mini-contactors TeSys LC SK and LP SK Environment Rated insulation voltage (Ui) Conforming to 0, VDE 00 gr C,BS, CSA - n, UL 0 V 0 Conforming to standards IEC 0, NF C -0,

More information

FUJI Magnetic Contactors and Motor Starters

FUJI Magnetic Contactors and Motor Starters FUJI Magnetic Contactors and Motor Starters Technical Information AEH28a CONTENTS Chapter Contactors and Starters - International standards... 4-2 Ratings and specifications... 8-3 Performance and characteristics...

More information

Softstarter Intelligent Controllers

Softstarter Intelligent Controllers Softstarter Intelligent Controllers Series Modes of Operation (Standard) Soft Start 100% Percent Voltage Initial Torque Start Run This method has the most general application. The motor is raised from

More information

ADS7 AC Contactor Starters

ADS7 AC Contactor Starters ADS7 AC Contactor Starters ADS7 starters fully comply with BS EN 60947-4-1, IEC 60947-4-1 and VDE 0660. The range offers a multitude of configurations and optional features including a complete choice

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

Contactors (9 to 85A)

Contactors (9 to 85A) Contactors (9 to 85A) Frame size 9A 12A 18A 22A -pole Contactors For further technical information see pages 8-9. includes AU-1 auxililary switch, (1 N.O. / 1 N.C.) Types AC coil DC coil GMC-9 GMD-9 GMC-12

More information

ABB s new control and protection devices

ABB s new control and protection devices ABB s new control and protection devices One product family ABB presents a new generation of first-class specialized components: manual motor starters, contactors, overload relays and softstarters for

More information

Page 2-4 Page 2-8. Page Page 2-12

Page 2-4 Page 2-8. Page Page 2-12 Page -4 Page -8 THREE-POLE CONTCTORS IEC Ith ratings in C1 duty at 40 C: 16 to 1600 IEC Ie ratings in C3 440V duty: 6 to 630 IEC Power ratings in C3 400V duty:. to 335kW UL/CS ratings: 3 to 500HP at 480V

More information

Switches Section 1. Load Break Switches. Accessories for Load Break Switches. 4 Pole Part Price Each Reference

Switches Section 1. Load Break Switches. Accessories for Load Break Switches. 4 Pole Part Price Each Reference Load Break Switches According to BS EN60947-3 High Thermal & Dynamic Strength Fully rated suitable for distribution & motor loads Auxiliary contacts also available Fully Visible Breaking Arduous categories

More information

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30 Contactors KNL KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30 Adaptable to various control requirements with ability of mounting from one to four additional auxiliary contacts. Versatile product capable

More information

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101 IEC CONTACTORS Description: RT01 Contactors Are Available With Cage Clamps On The Main Terminal Connections As Well As The Auxiliary Terminal Connections. RT02, RT0 and RT04 Contactors Are Available With

More information

Components for EEx e Panels

Components for EEx e Panels Circuit Interrupters / Motor Switches 8006/3 8543/1 8543/2 8548/2 40 A 63 A 80 A 1 160 A 500 V 660 V 500 V 01766E00 No. of poles 12 poles Isolator features Switching capacity 400 V, AC3 11 kw 22 kw 37

More information

ВЫСОКОНАДЕЖНЫЕ МОДУЛЬНЫЕ КОНТАКТОРЫ VMTEC 3P, 4P

ВЫСОКОНАДЕЖНЫЕ МОДУЛЬНЫЕ КОНТАКТОРЫ VMTEC 3P, 4P ВЫСОКОНАДЕЖНЫЕ МОДУЛЬНЫЕ КОНТАКТОРЫ VMTEC 3P, 4P Высоконадежные модульные контакторы VMtec созданы для обеспечения высокой производительности, гибкости, безопасности и экономически эффективных решений.

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION TECHNICAL SPECIFICATION Star/delta starter Description: The electromagnetic starters LT 3 Dxx series are devices designed for remote control, direct control and protection of induction motors coiled and

More information

For Info: Phone: Fax:

For Info:   Phone: Fax: Page -2 TWO POLES IEC rated current Ith: 20A (AC1) IEC operational power: 1.3kW (AC3 230V) Ideal for domestic applications. Page -2 THREE AND FOUR POLES IEC rated current Ith: 25A, 40A and 63A (AC1) IEC

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information

Industrial contactors CTX-1

Industrial contactors CTX-1 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 Industrial contactors /04/05/10/12/14/15/20/22/24/25/30/32/34/35/40/42/44/45 CONTENTS PAGE 1. Use... 1 2. Range... 1 3. Electrical

More information

Modular contactors and relays

Modular contactors and relays pages /4 to / pages /8 and /9 pages /10 and /11 pages /12 and /13 Presentation and standards Presentation Designed for use in modular panels and enclosures, these contactors feature : i Easy installation

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A Fuse protection fuser_548_a cat The solution for > Motor load break. > Protection of industrial cabinet. FUSERBLOC 6 to 25 A Strong points fuser_52_a cat Function FUSERBLOC 2 to 4 A FUSERBLOC are manually

More information

7 Switching Equipment and Control Devices

7 Switching Equipment and Control Devices 7 Switching Equipment and Control Devices Contactors.....................................................................494 Small-size contactors of KMI series.....................................................494

More information

Mini contactors. Mini contactors providing various connections and Accessories. Screw clamps. Ratings. For fast-on connections

Mini contactors. Mini contactors providing various connections and Accessories. Screw clamps. Ratings. For fast-on connections Mini contactors providing various connections and Accessories Screw clamps Fast-on Ratings AC3 ratings (IEC609-) Frame size 220 ~ 280 ~ 0 ~ 20V 0V 5V 690V 6A 1.5kW 2.2kW 3kW 3kW A 6A 5A A 9A 2.2kW kw 3.kW

More information

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function The solution for Load break switches sdmat_066_a cat > Main switchboard > Distribution panel > Motor load break unction SIDERMT 4 x 630 External front operation SIDERMT are manually operated 3 or 4 pole

More information

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400 Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O

CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O Data sheet CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O The MCI soft starters are designed for soft starting and stopping of 3 phase AC motors, thus

More information

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5 3-pole DC Operated Ratings Rated Aux. Contacts Type Coil voltage 1) AC2 Current Built-in Additional 24 24V= DC 5 AC3 see 48 60V= DC 6 380V AC1 page 34 110 110V= DC 7 400V 660V 220 220V= DC 8 415V 690V

More information

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved

More information

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660 Characteristics Environment Rated insulation voltage (Ui) Conforming to IEC/EN 60947-1, V 690 IEC/EN 60947-4-1, VDE 0110 gr C, CSA - n 14, UL 508.1 Conforming to standards IEC/EN 60947-1, IEC/EN 60947-4-1,

More information

Contactors and Overload Relays

Contactors and Overload Relays Contactors and Overload Relays Catalogue 2011 2 CONTENT Contactor Introduction...4 Range over view...8 Technical information - CN Series...10 Add on accessories - CN Series...12 Accessory fitment over

More information

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES DCX-M changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES FOR COMMERCIAL BUILDINGS AND DCX-M In = 63 A Quality & design CONFORM TO EN/IEC

More information

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101428D0201 28/03/11 -.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits. NF(Z)

More information

ICG Switchgear Price List 2009

ICG Switchgear Price List 2009 ICG Switchgear Price List 2009 Section 1 Control Gear Page Contactors (AC,DC & Modular) 2,3 Overload Relays 4 Product Accessories 4,5 Starters-DOL, Star-Delta, Fan/Vibrators, Reversing/Twin 6,7 Section

More information

SWITCH FUSES 3KL71 from 32A to 800A Description

SWITCH FUSES 3KL71 from 32A to 800A Description from 32A to 800A Description SWITCH FUSES 3KL71 3KL71 is a range of load-break switches suitable for making and breaking on load and disconnetting low voltage electrical circuits. They are commonly used

More information

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00, Low-Voltage Controls and Distribution > Industrial Controls > Protection Equipment > Circuit Breakers/Motor Starter Protectors > Motor Starter Protectors SIRIUS RV up to 00 A RV0-0DA5 CIRCUIT-BREAKER,

More information

DPX moulded case circuit breakers

DPX moulded case circuit breakers BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.

More information

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data B6, B7, BC6, BC7, TBC7 - and 4-pole mini contactors VB6, VB7, VBC6, VBC7 - and 4-pole mini reversing contactors Main pole Utilization characteristics according to IEC Standards IEC/EN 60947-1, IEC/EN 60947-4-1