CJX2N Series AC Contactor

Size: px
Start display at page:

Download "CJX2N Series AC Contactor"

Transcription

1 AC Contactor 18 page 1 page 1 page 131 page 13 page 13 page 133 page 13 page 135 page 136 page 136 page 137 page 138 CJXN CJXN CJXD LA1D Series Contactor Blocks LAD Series Contactor Blocks LC1F Bobbin of AC Contactor 3TF 3TB 3T GMC SQK

2 CJXN CJXN 0 CJXN 118 CJXN 538 CJXN series AC contactor is suitable for using in the circuits up to the rated voltage AC 50z or 60z, rated current up to 5A, for making, breaking, frequently starting & controlling the AC motor. Combined with the auxiliary contact block, timer delay & machineinterlocking device etc, it becomes the delay contactor, mechanicalinterlocking contactor, stardelta starter. With the thermal relay, it is combined into the electromagnetic starter. The contactor is produced according to IEC 7, VDE 0660 & BS55. Specifications Rated operation current Ie max AC3 (Ue 0V) Ie AC1 (0 60 ) Rated operational voltage Poles (P) /0V Rated 3/00V operational /0V power 500V in AC3 660/60V 0V Auxiliary contacts Compatible manualauto thermal overload relays Contactor type references Reversing contactor type references Class 10A Class Suppressor modules (d.c. and low consumption contactors have builtin suppression as standard) Interfaces Varistor Diode RC circuit Bridirectional peak limiting diode Relay Relay+override function Solid state ~ or 3P ~ P P ~ 3P 3P ~ P P A 1A 18A 5A 3A 38A 5A 3A 0A 50A 60V KW 3KW KW KW KW KW KW KW KW 11KW KW 18.5KW KW KW KW 11KW KW 18.5KW KW KW 10KW KW 18.5KW 18.5KW KW KW 10KW KW 18.5KW 18.5KW 1 N/C and 1 N/O instantaneous incorporated in the contactors, with addon blocks common to the whole range comprising up to N/C or N/ O instantaneous, up to 1 N/O+1 N/C time delay and up to N/O or N/C protected contacts and screen continuity terminals A A A 0.103A A A.510A.513A.518A.53A CJXN0 CJXN1 CJXN18 CJXN5 CJXN3 CJXN38 CJXN1 CJXN1 CJXN5 CJXN5 LC1DN0 CJXN1 LCD18 LCD5 LC1DN0 CJXN1 LCD18 LCD5 LCD3 LCD3 LCD38 LCD38 CJXN1 CJXN1 LCD5 LCD5 1

3 CJXN CJXN series AC contactor is suitable for using in the circuits up to the rated voltage AC 50z or 60z, rated current up to 5A, for making, breaking, frequently starting & controlling the AC motor. Combined with the auxiliary contact block, timer delay & machineinterlocking device etc, it becomes the delay contactor, mechanicalinterlocking contactor, stardelta starter. With the thermal relay, it is combined into the electromagnetic starter. The contactor is produced according to IEC 7, VDE 0660 & BS55. CJXN, 5 CJXN 1, 0 CJXN 170 Specifications Rated operation current Ie max AC3 (Ue 0V) Ie AC1 (0 60 ) Rated operational voltage Poles (P) /0V Rated 3/00V operational /0V power 500V in AC3 660/60V 0V Auxiliary contacts Compatible Class 10A manualauto thermal overload relays Class Suppressor modules (d.c. and low consumption contactors have builtin suppression as standard) Interfaces Varistor Diode RC circuit Bridirectional peak limiting diode Relay Relay+override function Solid state Contactor ~ or 3P type eferences ~ P P Reversing ~ 3P contactor 3P type ~ P references P 0A 60A 50A A 65A A A 5A 0V on ~ supply, 60V on supply KW 18.5KW KW KW KW KW KW KW 5/KW KW 33KW KW 18.5KW KW 37KW 37KW 37KW 37KW KW 37KW 5KW 55KW 5KW 5KW 5KW 5KW 5KW 55KW 5KW 5KW 1A 0A 3 KW 55KW 5KW 75KW KW 75KW 0A 3 0KW 75KW KW 0KW KW 0KW 1 N/C and 1 N/O instantaneous incorporated in the contactors, with addon blocks common to the whole range comprising up to N/C or N/ O instantaneous, up to 1 N/O+1 N/C time delay and up to N/O or N/C protected contacts and screen continuity termials 1750A 1770A 17A 1710A 1710A 600A 600A 170A 1765A 1770A 17A 600A 600A CJXN0 CJXN65 CJXN CJXN50 CJXN5 CJXN0 CJXN0 LCD0 LCD0 LCD50 CJXN65 CJXN65 LCD65 LCD65 CJXN CJXN LCD LCD LCD5 CJXN1 CJXN1 CJXN1 LCD1 LCD1 CJXN0 LCD0 1

4 CJXD CJXD0, 1 CJXD series AC contactor is suitable for using in the circuits up to the rated voltage AC 50z or 60z, rated current up to 5A, for making, breaking, frequently starting & controlling the AC motor. Combined with the auxiliary contact block, timer delay & machineinterlocking device etc, it becomes the delay contactor, mechanicalinterlocking contactor, stardelta starter. With the thermal relay, it is combined into the electromagnetic starter. The Contactor is produced according to IEC 7, VDE 0660 & BS55. Specifications CJXD0 CJXD1 CJXD18 CJXD5 CJXD3 Rated working AC AC AC3 capacity of phase 3 squirrelcage motor AC3(KW) /V 3/00V V 0V 500V /60V Rated heat Electrical life AC x Mechanical AC3 x 10 6 CJXD5, 3 Number of the contact Rated working AC3 capacity of phase 3 squirrelcage motor AC3(KW) Rated heat Electrical life AC x 10 Mechanical Number of the contact AC3 AC /V 3/00V V 0V 500V 660/60V AC3 x 10 6 CJXD0 CJXD50 CJXD NO CJXD CJXD CJXD, 5 Volts (VAC) 8 / 0 3/ z B5 D5 E5 F5 M5 P5 U5 Q5 V5 N5 R5 S5 Y5 60z B6 D6 E6 F6 M6 U6 Q6 R6 50/60z B7 D7 E7 F7 M7 P7 U7 Q7 V7 N7 R7 131

5 LA1D Series Contactor Blocks LA1D series auxiliary contact blocks are installed at the top of LAD control relay or LC1D contactor for expanding the couples of auxiliary contacts points. Owing to adopt the contacting functions of sliding friction, the item can be selfcleaning & ensure the electric circuit to be reliable. LA1D11 (NEW) Technical specifiction LA1D LA1D11 LA1D LA1D LA1D0 Contact number NC NO+NC NO NO+NC NO LA1D0 LA1D13 LA1D31 NC 1NO+3NC 3NO+1NC LA1D (NEW) LA1D11 LA1D LAD Series Contactor Blocks LAD time delay auxiliary contact blocks are combined with LC1D AC contact & LA1D auxiliary contact block into be LC3D stardelta reduced coltage starter to start motor. Technical specifiction Delay range Number of the delay contacts LAD (NEW) LADT0 LADT LADT LADRS 0.13s 101s 0.1s 0.1s NO+NC LADR LADR 101s 0.13s Dimensions LAD 13

6 LC1F LC1F series AC contactor is applicable to the circuits up to the rated voltage 0V AC 50z or 60z, rated current up to 7A, for long distance breaking circuit and frequently starting or control the motor. It also can be used for the control of distribution circuits of rated current from A to 0A. LC1F1 Specifications Rated operation AC1 AC3 LC1F1 1 0 LC1F LC1F LC 5 3 LC V Standard power ratings of 3phase motors AC3 (kw) 3V V 0V 500V V 1 0V LC1F0 Rated operation AC1 AC3 LC1F LC1F LC1F LC1F6 6 0 LC1F7 7 0 V 17 0 Standard power ratings of 3phase motors AC3 (kw) 3V V 0V 500V V V Dimensions LC1F5 Amax Bmax Cmax a B φ CXCF1 F /1 6.5 CXCF185 F /1 6.5 CXCF /1 6.5 LC1F7 CXCF /1 6.5 CXCF /

7 Bobbin of AC Contactor LX1D LX1D LX1D6 LX1FF LX1FJ LX1F LX1F3 LX1D LC1D0 to LC1D18 LX1D LC1D5 to LC1D3 LX1D6 LC1D0 to LC1D5 LX1FF LC1F1 to LC1F0 LX1FG LC1F185 to LC1F5 LX1F LC1F65 to LC1F3 LX1FJ LC1F00 LX1FK LC1F500 LX1F LX1FL LC1F6 LX1FK(1) LC1F7 13

8 3TF 3TF, 31 3TF series AC contactor are suitable in electrical system with AC 50/60z, rated operational voltage up to. In AC3 usage, rated operational voltage up to 3V, rated operational current up to 6A to make or break remote motors or system. They form electromagnetic starters with suitable thermal overload or phasefailure. They are made according to IEC 607, BS 5 & VDE The contactor is a straight motion mechanism having double breaking contacts. The auxiliary contacts are arranged NO.NC at most, it is employed the flexible locking connection between the contact support and core, three are no arcisolated panel in the Ie A contactor. In the In 3A contactors. Three are moulded arcchute with arcisolated panel, because all contacts are made of high cnonfusibility and against corrosion siliver alloy. All series products can be mounted by screw, Ie 3A contactor also by installation rail. Specifications 3TF3, 33 3TF, 5 3TF0 3TF1 3TF 3TF3 3TF 3TF5 3TF6 3TF7 3TF8 3TF 3TF50 3TF51 3TF5 3TF53 3TF5 3TF55 3TF56 3TF58 Rated operation Rated operation Controllable power for motor (kw) AC3 AC 3V 3V 3V of auxiliary contact NO NC 1NO+1NC NO+NC NO+NC NO+NC 3TF6, 7 3TF0 3TF 135

9 3TB 3TB1 The contactor is suitable for using in the circuits up to the rated voltage AC 50z or 60z, rated current 6A, for making and breaking, and for frequent starting and controlling the motor. After combined with the mechanical interlocking device, it becomes 3TD series convertible contactor for controlling, starting, breaking and reversing of the motor. The products comply with IEC607& VDE0660. Technical specification Rated thermal Rated operating current at 3V (A) Rated operating current at (A) The power of controlled motor (kw) 3V of auxiliary contact CJX(3TB0) CJX(3TB1) CJX(3TB) NO 1NC 1NO+1NC NO+NC CJX(3TB3) CJX(3TB) NO+NC 3TB 3T The auxiliary contactors is the auxiliary suited by controlled circuit which voltage is AC 50/60z, and DC. They control all kinds of magnetic coil and amplify or transfer signal to relative controlled element simultaneously. They are characterized by high performance & long service life. Technical specification 3T 3T8 3T 00A 310A A 1A 00A 3T8 0A 710A 6A 5A 0A of contact NO NC Rated Voltage V V 3V 0V Rated operational current(a) le=ac11, AC DC Controllable motor power AC3 (KW). 136

10 GMC Technical specification GMC IEC607 AC1 duty AC3 duty 00V V V 60V UL Continuous current (th) AC Motor single 1V phase V Three 0V phase V 60V 575V Aux. contact Side mounting Top mounting Panel installation External dimension (mm) (WxxD) GMC A.5KW 11A KW A KW 7A KW 5A A 0.5P 1P P P 5P P AU1 AU, AU Rail & screw xx86.8 GMC1 A 3.5KW 13A KW 1A KW 1A KW A 5A 0.5P P 3P 3P P 10P GMC18 5A.5KW 18A KW 18A KW 13A KW A A 1P 3P 5P 5P 10P P GMC 3A KW A 11KW A KW A KW 18A 3A P 3P 7P P 10P P GMC IEC607 AC1 duty AC3 duty 00V V V 60V UL Continuous current (th) AC Motor single 1V phase V Three 0V phase V 60V 575V Aux. contact Side mounting Top mounting Panel installation External dimension (mm) (WxxD) GMC3 50A kw 3A kw 3A 18.5kW 8A 18.5kW 1A 5A P 5P P 10P P P AU1 AU, AU Rail & screw 68x8x.6 GMC0 60A 11kW 0A 18.5kW 0A kw 3A kw 5A 50A 3P 5P 10P 10P 5P 5P GMC50 A kw 55A kw 50A kw 3A kw 33A 70A 3P P 10P P P P x13.5x117. GMC65 A 18.5kW 65A kw 65A 37kW 60A 37kW 7A A 5P 10P P P 0P 0P GMC 5085 GMC IEC607 AC1 duty AC3 duty 00V V V 60V UL Continuous current (th) AC Motor single 1V phase V Three 0V phase V 60V 575V Aux. contact Side mounting Top mounting Panel installation External dimension (mm) (WxxD) GMC75 A kw 75A 37kW 75A 5kW 6A 5kW 7A 0A 5P P P 5P 50P 50P AU1 AU, AU Rail & screw x13.5x117. GMC85 135A 5kW 85A 5kW 85A 5kW 75A 5kW 5A A P P 5P P 50P 50P GMC 0A kw 105A 55kW 105A 55kW 85A 55kW 65A A P P P P 60P 60P AU Screw x7.x16.5 GMC 0A 37kW A 60kW 1A 60kW 0A 60kW 70A A 10P P 0P 0P 75P 75P 137

11 SQK SQK specifications SQK SQK/N Rated working voltage (V) Rated working AC3 3V AC Rated heat Connecting max. 3V Breaking max. 3V AC3 capacity of V phase 3 squirrelcage 3V motor AC3(kW) Operation Electrical AC3 frequency time/h life AC Electrical AC3 life x 10 AC Mechanical life x 10 Wire (mm ) Suitable fuse Number for contact SQK0610 SQK0601 SQK0600 SQK (60) NT006 NO NO+NC SQK010 SQK001 SQK000 SQK (60) NT006 NO NO+NC SQK SQK11 SQK10 SQK (60) NT006 NO NO+NC SQE specifications SQE SQE/N Rated working voltage (V) Rated working 3V Rated heat Connecting max. Breaking max. AC3 capacity of phase 3 squirrelcage motor AC3(kW) Operation Electrical frequency time/h life Electrical life x 10 Mechanical life x 10 Wire (mm ) Suitable fuse Number for contact AC3 AC 3V 3V V 3V AC3 AC AC3 AC SQE0610 SQE0601 SQE NT006 NO+NC SQK010 SQK001 SQK (60) NT006 NO+NC 138

ELECTRIC PRODUCT CATALOGUE

ELECTRIC PRODUCT CATALOGUE ELECTRIC PRODUCT CATALOGUE!"#$%&' www.cetelec.com.cn SHANGHAI CET ELECTRIC CO. LTD. is one of the leading and the most reliable manufacturers and exporters for low voltage and high voltage electric products

More information

Safety Protection. Catalogue 2013/2014 Contactor & Overload Relay MAXTRIC. circuit breaker.

Safety Protection. Catalogue 2013/2014 Contactor & Overload Relay MAXTRIC. circuit breaker. Safety Protection Catalogue 03/0 Contactor & Overload Relay MAXTRIC circuit breaker Working with the world s electric specialist together @ www.huayuelectric.com AC Contactor series AC Contactors, 3P AC

More information

Low voltage switch gear

Low voltage switch gear Low voltage switch gear Omron is an established global manufacturer of low voltage switch gear (LVSG) products, and the company s new series (J7) complements the existing portfolio. High power-handling

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

22AF 40AF AF 150AF 225AF 400AF 800AF

22AF 40AF AF 150AF 225AF 400AF 800AF Contactors MC-Series UL508 E108780 Contactor 3 Pole Standards and Certifications UL508 IEC 60947-2 & IEC 60947-4-2 CSA C22.2 No.14 Features 8 Frame Sizes 1/2HP up to 600HP @ 480V AC Screw Terminals (Lug

More information

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30 Characteristics TeSys contactors Mini-contactors TeSys LC SK and LP SK Environment Rated insulation voltage (Ui) Conforming to 0, VDE 00 gr C,BS, CSA - n, UL 0 V 0 Conforming to standards IEC 0, NF C -0,

More information

Price List. Switching and Controlling Products. With effect from July 01, schneider-electric.co.in

Price List. Switching and Controlling Products. With effect from July 01, schneider-electric.co.in Price List Switching and Controlling Products With effect from July 01, 2017 schneider-electric.co.in Price List Contents EasyPact TVS EasyPact TVS Power Contactors (3 Pole)....6 EasyPact TVS Power Contactors

More information

Switching and Controlling Products. Price List

Switching and Controlling Products. Price List Price List Switching and Controlling Products With effect from July 01, 2017 AUTHORISED DEALERS OF "TARGET" & "AGRONIC" PRODUCTS : 4,MAHAVIR PRAKASH,V.B.LANE,GHATKOPAR(E),MUMBAI-400077 MOBILE : 09820817655,E-mail

More information

Ktec Contactors and thermal overloads

Ktec Contactors and thermal overloads Contactors and thermal overloads Techna KTEC series contactors provide a complete solution for your ac contactor requirements.the range carries TUV, UL & CSA certification, for use in Europe, North America

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

Description. Positive safety relays

Description. Positive safety relays Type N & KC Positive safety Description A.C. or D.C. operated DIN rail or panel mounting 600 volt heavy duty design, A600-10 amp, Q300-5 amp Snap-on accessories available: 1 & 4 pole adder deck Pneumatic

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors 90 Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 5424 Product certifications LCp

More information

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30 Contactors KNL KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30 Adaptable to various control requirements with ability of mounting from one to four additional auxiliary contacts. Versatile product capable

More information

PriceList. Switching and Controlling Products. With effect from March 12, schneider-electric.co.in

PriceList. Switching and Controlling Products. With effect from March 12, schneider-electric.co.in PriceList Switching and Controlling Products With effect from March 12, 2018 schneider-electric.co.in Price List Contents EasyPact TVS EasyPact TVS Power Contactors (3 Pole).... 6 EasyPact TVS Power Contactors

More information

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload According to CE, IEC 947, EN 60947 Contactor Catalogue 3 Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload Mini-Contactors 4kW - 5.5kW DC Contactors Mini-Relays 10A Motor Starter DOL, Star-Delta Capacitor

More information

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660 Characteristics Environment Rated insulation voltage (Ui) Conforming to IEC/EN 60947-1, V 690 IEC/EN 60947-4-1, VDE 0110 gr C, CSA - n 14, UL 508.1 Conforming to standards IEC/EN 60947-1, IEC/EN 60947-4-1,

More information

TeSys D Overload Relays

TeSys D Overload Relays TeSys D Contactors and Overload Relays TeSys D Overload Relays Table.24: TeSys D Overload Relays Ambient Compensated, Bimetallic, Direct Mounting Current Setting Range (A) For Direct Mounting to LC1...

More information

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1 Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5 3-pole DC Operated Ratings Rated Aux. Contacts Type Coil voltage 1) AC2 Current Built-in Additional 24 24V= DC 5 AC3 see 48 60V= DC 6 380V AC1 page 34 110 110V= DC 7 400V 660V 220 220V= DC 8 415V 690V

More information

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101408D0201 25/03/11-30-01-.. / Z-30-01-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101415D0201 25/03/11 AF30-30-11-.. / AF30Z-30-11-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF30(Z) contactors are used for controlling power circuits

More information

AF09... AF38 3-pole contactors 4 to 18.5 kw, AC / DC operated

AF09... AF38 3-pole contactors 4 to 18.5 kw, AC / DC operated AF09... AF3 3-pole contactors 4 to 1.5 kw, AC / DC operated AF09-30-10 AF09... AF3 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and 220 V DC. These contactors

More information

AE 9... AE 40 Contactors NE... Contactor Relays

AE 9... AE 40 Contactors NE... Contactor Relays Technical data AE 9... AE 0 Contactors NE... Contactor Relays AE 9... AE 0 Contactors NE.. Contactor Relays Contents AE 9... AE 0 Contactors Description... 2 Ordering Details... 3 Technical Data... Terminal

More information

ASL09..S 3-pole Contactors - Spring Terminals

ASL09..S 3-pole Contactors - Spring Terminals 4 kw 5 hp ASL09..S 3-pole Contactors - Spring DC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Low coil consumption, - Polarity on the coil

More information

TAE pole Contactors

TAE pole Contactors TAE9...26 3-pole Contactors d.c. operated with double-winding coil SB8033C3 Utilisation TAE9 to TAE26 contactors are a compliment to the DC control contactor range. The coils have large voltage ranges

More information

5 - Contactors. Mini-contactors type LC1 SKGC. TeSys LCp F contactors and reversing contactors

5 - Contactors. Mini-contactors type LC1 SKGC. TeSys LCp F contactors and reversing contactors Contents 0 - Contactors Selection guides.............................................page /2 b General, selection of contactors....................... pages /16 k contactors and reversing contactors b

More information

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors...

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors... Three-pole versions up to 630A in IEC AC3 duty Four-pole versions up to 1600A in IEC AC1 duty Versions for power factor correction up to 100kvar at 400VAC Four-pole versions with NO+NC or 4NC main poles

More information

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101412D0201 25/03/11-30-00-.. / Z-30-00-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

C -5 to +55 (0.8 to 1.1Uc) Permissible o

C -5 to +55 (0.8 to 1.1Uc) Permissible o T - Line Contactors 3 & 4 Pole Contactors with C operating coils General Characteristics Type Unit TC1-D09 ~ TC1-D95 Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 VDEO 110grC/IEC 60947-4

More information

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories Mini Contactor Relays 4-pole J7KN-R ) Main contactor C & DC operated 4-, 6- and 8-pole versions in different configurations Positively guided contacts Screw fixing and snap fitting (35 mm DIN rail) Rated

More information

Short form catalogue Motor protection and control Block contactors and overload relays

Short form catalogue Motor protection and control Block contactors and overload relays Short form catalogue Motor protection and control Block contactors and overload relays Motor rated operational powers and currents The currents given below concern standard three-phase four-pole cage motors

More information

OSS - TN, TBN Type. Information to Order. Features. External View ATS(60~600A) OSS P- A B C D. Rated Current. D Operating Voltage

OSS - TN, TBN Type. Information to Order. Features. External View ATS(60~600A) OSS P- A B C D. Rated Current. D Operating Voltage Information to Order A Rated Current 06 1 60A 100A 2 4 400A 6 600A B Type TN : TN-Type TBN : TBN-Type C Number of Poles 2 : 2P 3 : 3P 4 : 4P OSS - 6 - - P- A B C D D Operating Voltage A1 : AC 110V A2 :

More information

Switches Unlimited Phone: * Fax:

Switches Unlimited Phone: * Fax: For Info: sales@switchesunlimited.com www.switchesunlimited.com Phone: 800-1-0487 Fax: 718-67-6370 Page -4 Page -8 THREE-POLE CONTACTORS IEC Ith ratings in AC1 duty at 40 C: 16 to 1600A IEC Ie ratings

More information

Page 2-4 Page 2-8. Page Page 2-13

Page 2-4 Page 2-8. Page Page 2-13 Page -4 Page -8 THREE-POLE CONTACTORS IEC Ith ratings in AC1 duty at 40 C: 16 to 1600A IEC Ie ratings in AC3 440V duty: 6 to 630A IEC Power ratings in AC3 400V duty:. to 335kW UL/CSA ratings: 3 to 500HP

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

NR2 Thermal Overload Relay. 1. General. 2. Type Designation. 3. Features. Relays. EU Germany Ukrain Russia South Africa USA

NR2 Thermal Overload Relay. 1. General. 2. Type Designation. 3. Features. Relays. EU Germany Ukrain Russia South Africa USA R Relays C US LISTED EU Germany Ukrain Russia South Africa USA NR Thermal Overload Relay. General. Certificates: CE, VDE, Ukrain, PCT, RCC, UL;. Electric ratings: AC 50/0Hz, 90V, 0.A~30A;.3 Tripping class:

More information

ABB s new control and protection devices

ABB s new control and protection devices ABB s new control and protection devices One product family ABB presents a new generation of first-class specialized components: manual motor starters, contactors, overload relays and softstarters for

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series

More information

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France Contact us ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F-69687 Chassieu cedex / France You can find the address of your local sales organisation on

More information

Quick selection table

Quick selection table Quick selection table Contactors... 100 to 800A Frame size 100A 15A 150A -pole Contactors s AC/DC common coil See page 46 for more details CGC-100 CGC-15 CGC-150 See page 46 for more details Ratings /

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

About us. Switchgear Factory, Mumbai

About us. Switchgear Factory, Mumbai About us Larsen & Toubro is a technologydriven USD 8.5 billion company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field of Engineering, Construction,

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

3RT14 Contactors with 3 Main Contacts

3RT14 Contactors with 3 Main Contacts 3RT14 Contactors with 3 Main Contacts for Switching Resistive Loads Contactor Size 3RT14 46 Mechanical endurance Oper. 10 million Electrical endurance Oper. 0.5 million C-1 utilization category at I e

More information

Components for EEx e Panels

Components for EEx e Panels Circuit Interrupters / Motor Switches 8006/3 8543/1 8543/2 8548/2 40 A 63 A 80 A 1 160 A 500 V 660 V 500 V 01766E00 No. of poles 12 poles Isolator features Switching capacity 400 V, AC3 11 kw 22 kw 37

More information

US Catalog. Motor protection and control AF Range contactors & overload relays

US Catalog. Motor protection and control AF Range contactors & overload relays US Catalog Motor protection and control AF Range contactors & overload relays Motor rated operational powers and currents The currents given below concern standard three-phase four-pole cage motors (500

More information

PriceList. Switching and Controlling Products. With effect from January 18 th, schneider-electric.co.in

PriceList. Switching and Controlling Products. With effect from January 18 th, schneider-electric.co.in PriceList Switching and Controlling Products With effect from January 18 th, 2019 schneider-electric.co.in Price List Contents EasyPact TVS EasyPact TVS Power Contactors (3 Pole)... 6 EasyPact TVS Power

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

Contactors (9 to 85A)

Contactors (9 to 85A) Contactors (9 to 85A) Frame size 9A 12A 18A 22A -pole Contactors For further technical information see pages 8-9. includes AU-1 auxililary switch, (1 N.O. / 1 N.C.) Types AC coil DC coil GMC-9 GMD-9 GMC-12

More information

1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175.

1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175. SIRIUS 3RT0 3-Pole with AC Coil 3RT0* through 3RT04* 4-point AC coil can be wired on top, bottom, or diagonally. Direct mount 3RU or 3RB0 solid state overload relays to create starters. Snap-on auxiliary

More information

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1 Motor Contactor J7KN Range from 4 to 500 kw (AC 3, 380/415 V) AC and DC operated Integrated auxiliary contacts; integrated aux. contact of J7KN contactors up to 11kW suitable for electronic circuits Screw

More information

Auxiliary contact blocks - with spring terminals Accessories

Auxiliary contact blocks - with spring terminals Accessories Auxiliary contact blocks - with spring terminals Accessories CA3-10S 1SBC101037F0014 Description The auxiliary contact blocks are used for the operation of auxiliary circuits and control circuits. CA3

More information

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101 IEC CONTACTORS Description: RT01 Contactors Are Available With Cage Clamps On The Main Terminal Connections As Well As The Auxiliary Terminal Connections. RT02, RT0 and RT04 Contactors Are Available With

More information

Motor Starting Solutions Open Type Version, in Kit Form

Motor Starting Solutions Open Type Version, in Kit Form Motor Starting Solutions Open Version, in Kit Form Starters Protected by Manual Motor Starters Direct-On-Line Starters I> Reversing Starters I> MS... Manual motor starter MS... Manual motor starter BEA...

More information

Essential equipment for all your requirements

Essential equipment for all your requirements NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides

More information

Motor Starters. Star-Delta Starters Open Type 86. Star-Delta Starters Enclosed 88 Enclosure for Star-Delta Starters 88.

Motor Starters. Star-Delta Starters Open Type 86. Star-Delta Starters Enclosed 88 Enclosure for Star-Delta Starters 88. Motor Starters Star-Delta Starters Open Type 86 Star-Delta Starters Enclosed 88 Enclosure for Star-Delta Starters 88 Accessories 89 Reversing Contactors 90 Pole Changing Starters 92 Technical Data 94 Wiring

More information

* With I-Option card only (C. T. connection) Basic connections with isolated contacts

* With I-Option card only (C. T. connection) Basic connections with isolated contacts Typical Circuit Diagrams. Typical Circuit Diagrams Basic connections with isolated contacts F2 - Overload relay Q1 - MPCB / ACB / MCCB /K2 - Main isolating contactors (AC-3 rated) F3 - Semiconductor Fuses

More information

4 - Miniature controls

4 - Miniature controls Index -....1.22 Selection Contactors for connection to PLCs, B6S & B7S, 3 phase...6 Contactors, Interface, B6 & B7, 3 phase...5 Contactors, features...1 Contactors, mechanically interlocked, B6 & B7, 3

More information

Contactors RAST 5 D778E131

Contactors RAST 5 D778E131 Contactors RAST 5 D778E131 RAST 5 - exclusive for OEM-Partners 5 mm pitch connector system Advantages RAST 5 - Technology 59 mm Time saving installation Easy assembly without tools Tailor-made sockets,

More information

ВЫСОКОНАДЕЖНЫЕ МОДУЛЬНЫЕ КОНТАКТОРЫ VMTEC 3P, 4P

ВЫСОКОНАДЕЖНЫЕ МОДУЛЬНЫЕ КОНТАКТОРЫ VMTEC 3P, 4P ВЫСОКОНАДЕЖНЫЕ МОДУЛЬНЫЕ КОНТАКТОРЫ VMTEC 3P, 4P Высоконадежные модульные контакторы VMtec созданы для обеспечения высокой производительности, гибкости, безопасности и экономически эффективных решений.

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet SBC042D020 06/04/ -22-00-.. / Z-22-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440 V DC.

More information

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data B6, B7, BC6, BC7, TBC7 - and 4-pole mini contactors VB6, VB7, VBC6, VBC7 - and 4-pole mini reversing contactors Main pole Utilization characteristics according to IEC Standards IEC/EN 60947-1, IEC/EN 60947-4-1

More information

Star Series Motor protection & control

Star Series Motor protection & control Contact us ABB Inc. Low Voltage Control Products 16250 W. Glendale Drive New Berlin, WI 53151 Phone: 888-385-1221 Fax: 800-726-41 USA Technical support & Customer Service: 888-385-1221, Option 4 7:30AM

More information

Module 2 CONTROL SYSTEM COMPONENTS. Lecture - 4 RELAYS

Module 2 CONTROL SYSTEM COMPONENTS. Lecture - 4 RELAYS 1 Module 2 CONTROL SYSTEM COMPONENTS Lecture - 4 RELAYS Shameer A Koya Introduction Relays are generally used to accept information from some form of sensing device and convert it into proper power level,

More information

Contactors. Contactors ensure positive safety between their auxiliary contact blocks. Easy coil change Captive terminal screws

Contactors. Contactors ensure positive safety between their auxiliary contact blocks. Easy coil change Captive terminal screws A9 - AF1650 11 Contactors A9 - A110 Maximum UL/CSA horsepower ratings according to UL508 and CSA22.2 No. 14 Includes NEMA sizes 00-3 CE mark Compact space saving design Standard auxiliary contact configurations:

More information

CI-TI TM Contactors and Motor Starters Contactors CI 6-50

CI-TI TM Contactors and Motor Starters Contactors CI 6-50 Data sheet CI-TI TM Contactors and Motor Starters Contactors CI 6-50 Description Danfoss contactors CI 6-50 cover the power range 2.2-25 kw. CI 6 is built up as a combined contactor/control relay. CI 9

More information

File E31519 Project 10CA February 4, 2011 REPORT MAGNETIC MOTOR CONTROLLERS. Siemens AG Amberg, Germany

File E31519 Project 10CA February 4, 2011 REPORT MAGNETIC MOTOR CONTROLLERS. Siemens AG Amberg, Germany File E31519 Project 10CA65262 February 4, 2011 REPORT on MAGNETIC MOTOR CONTROLLERS Siemens AG Amberg, Germany Copyright 2011 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the

More information

Accessories for Contactors and Contactor Relays

Accessories for Contactors and Contactor Relays 4/0 Accessories for Contactors and Contactor Relays Contents Accessories for A... Series and BC... Series Contactors and for Contactor Relays Auxiliary Contact Blocks - Front Mounting... 4/2 Auxiliary

More information

Standard voltages. Alternating current (V) /60Hz Alternating current (V)

Standard voltages. Alternating current (V) /60Hz Alternating current (V) Three and four pole contactors 50 to 825 (3) 200 to 250 () ontactors ontrol circuit: lternating current up to 690V irect current up to 500V egree of protection P00 (Pxx with accessories) K07...K3: auxiliary

More information

TeSys contactors. Characteristics. Environment Rated insulation voltage 5/50. Contactor type LC1 D09 D18 DT20 and DT25. DT60A and DT80A.

TeSys contactors. Characteristics. Environment Rated insulation voltage 5/50. Contactor type LC1 D09 D18 DT20 and DT25. DT60A and DT80A. Characteristics Contactor type LC1 D09 D18 DT20 and DT2 Environment Rated insulation voltage V 600 D2 D38 DT32 and DT40 D40A D6A DT60A and DT80A V 690 1000 D80 D9 D11 and D10 Rated impulse withstand voltage

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

CB to 1000 A. 1 to 4 single pin main poles with silver pad contacts.

CB to 1000 A. 1 to 4 single pin main poles with silver pad contacts. LEI-ELEC F 5470 GOCY CB 75 400 to 000 A types for each calibre: AC poles CBA 75 400, CBA 75 500, CBA 75 60, CBA 75 800, CBA 75 000. poles CBFC 75 400, CBFC 75 500, CBFC 75 60, CBFC 75 800, CBFC 75 000.

More information

Item Code Description Quantity 3NA LV HRC FUSE LINK S00 80A 690AC 250DC 30 3NA3832 LV HRC FUSE LINK GL/GG S00 125A 500VAC 250VDC 0

Item Code Description Quantity 3NA LV HRC FUSE LINK S00 80A 690AC 250DC 30 3NA3832 LV HRC FUSE LINK GL/GG S00 125A 500VAC 250VDC 0 Controlgear Products +27 () 11 97 116 sales@controlgear.co.za Siemens stock items on hand as at Mon, 3/4/218, 14:4 GMT+2 3NA3824-6 LV HRC FUSE LINK S 8A 69AC 25DC 3 3NA3832 LV HRC FUSE LINK GL/GG S 125A

More information

CI-TI Contactors and motor starters Types CI 61 - CI 98

CI-TI Contactors and motor starters Types CI 61 - CI 98 Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include

More information

FUJI Magnetic Contactors and Motor Starters

FUJI Magnetic Contactors and Motor Starters FUJI Magnetic Contactors and Motor Starters Technical Information AEH28a CONTENTS Chapter Contactors and Starters - International standards... 4-2 Ratings and specifications... 8-3 Performance and characteristics...

More information

ADS7 AC Contactor Starters

ADS7 AC Contactor Starters ADS7 AC Contactor Starters ADS7 starters fully comply with BS EN 60947-4-1, IEC 60947-4-1 and VDE 0660. The range offers a multitude of configurations and optional features including a complete choice

More information

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5- MKING MODERN LIVING POSSIBLE Technical brochure Minicontactors CI 5- www.danfoss.com 2 IC.PD.C10.F3.02-520B4167 Danfoss /S, C-SMC, mr, 07-2010 Contents Page Minicontactor CI 5- Introduction...............................................................................4

More information

D509E. Manual Motor - Starters

D509E. Manual Motor - Starters D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors

More information

Technical Information

Technical Information C5 C5- C5- C5- C5- C5-550 ➊ 700 860 1000 1200 Rated Insulation Voltage U i to IEC 947-1 [V] 1000V 1000V 1000V 690V 690V UL/CS [V] 600V Rated Impulse Voltage U imp C5-550 / 700 / 860 [kv] 3.5 C5-1000 /

More information

Mini Contactors CI 4-

Mini Contactors CI 4- Data sheet Mini Contactors CI 4- Introduction CI 4 minicontactors cover the power range 1.5 to 5.9 kw and are available for a.c. and d.c. coil voltages. Characteristic of the minicontactors is that they

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated 11Across the line UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated contactor frame size A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF

More information

Modular contactors and relays

Modular contactors and relays pages /4 to / pages /8 and /9 pages /10 and /11 pages /12 and /13 Presentation and standards Presentation Designed for use in modular panels and enclosures, these contactors feature : i Easy installation

More information

Technical Information

Technical Information Contactors Contactors 95(-EI) 110(-EI) 140(-EI) 180(-EI) 210-EI 250-EI 300-EI 420-EI 630-EI 860-EI Rated Insulation Voltage U i IEC, S, BS, SEV, VDE 0660 [V] 1000V UL; CS [V] 600V Rated Impulse Voltage

More information

Panorama. Contactors Motor protection Accessories

Panorama. Contactors Motor protection Accessories Panorama Contactors Motor protection Accessories Extensive range of contactors High performance contactors for your applications from 9 to 5000 A Mini contactors for compact equipments - up to 5.5 kw /

More information

THREE-POLE CONTACTORS series HR09-HR13 up to 6 kw

THREE-POLE CONTACTORS series HR09-HR13 up to 6 kw THREE-POLE CONTACTORS series HR09-HR3 up 6 kw USE Series HR contacrs are particularly suitable for controlling mors, heating elements and three-phase and single-phase loads in general. OPERATION AND INSTALLATION

More information

Certi cation Record INDUSTRIAL CONTROL EQUIPMENT Motor Controllers Magnetic

Certi cation Record INDUSTRIAL CONTROL EQUIPMENT Motor Controllers Magnetic Certi cation Record Customer Schneider Electric USA, Inc. Square D Raleigh (Knightdale) Plant, 8001 Knightdale Blvd Knightdale NC USA 27545 Class 3211 04 INDUSTRIAL CONTROL EQUIPMENT Motor Controllers

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

EW series Industrial contactors

EW series Industrial contactors 2012_EW_Contactors_bro_EN.qxd:Mise en page 1 31/08/12 10:24 Page 2 EW series Industrial contactors Hager offers a complete range of contactors for commercial market such as buildings, infrastructures,

More information

SD Series Non-Fused Load Switches

SD Series Non-Fused Load Switches SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load

More information

2.3 LA1-DN10, DN01 LA6-DK LA8-DN LA1-DN LC1-LP1 LA8-DN LA1-DN, DC LA2-DT, DS LA3-DR LA1-DX, DY, DZ

2.3 LA1-DN10, DN01 LA6-DK LA8-DN LA1-DN LC1-LP1 LA8-DN LA1-DN, DC LA2-DT, DS LA3-DR LA1-DX, DY, DZ 110-17V AC-DC 50/60Hz E1 E LA1-DN10, DN01 0 LA6-DK LA6 DK10 LA8-DN LA1-DN.3 LA8-DN LC1-LP1 LA1-DN, DC LA-DT, DS LA3-DR LA1-DX, DY, DZ See right-hand page for mounting possibilities according to the contactor

More information

Question Number: 1. (a)

Question Number: 1. (a) Session: Summer 2008 Page: 1of 8 Question Number: 1 (a) A single winding machine cannot generate starting torque. During starting the switch connects the starting winding via the capacitor. The capacitor

More information

Technical Information

Technical Information Technical Information KT7 Controller Time-Current Characteristic KT7 Manual Motor Starter/Protector 1. Thermal Release Trip Current The adjustable current-dependent delayed bimetal release protects motors

More information

IEC Utilization Categories (Explanation)

IEC Utilization Categories (Explanation) IEC Utilization Categories (Explanation) IEC Utilization Categories Voltage Category Typical Applications A.C. A.C. and D.C. D.C. AC AC AC AC ACa ACb AC6a AC6b AC7a AC7b AC8a AC8b AC AC AC AC AC AC AC

More information