Technical Data Submittal Document

Size: px
Start display at page:

Download "Technical Data Submittal Document"

Transcription

1 Project: ustomer: ngineer: Pump Manufacturer: Technical ata Submittal ocument Model cross the Line Start lectric ire Pump ontroller ontents: ata Sheets imensional ata Wiring Schematics ield onnections Note: The drawings included in this package are for controllers covered under our standard offering. ctual S ULT drawings may differ from what is shown in this package. ebruary

2 Submittal ata Sheet Model lectric ire Pump ontroller rom normal incoming power through isconnecting Means (S/) 3L3 T3 T2 T M R Starting Method: ull Voltage cross the line (irect on line) Typical Voltage pplied at Start: 00% nrush urrent: x normal load current Starting Torque: 00% Motor Type: cross the line (irect on line) No. of ontactors: at 00% of horsepower Min. ampacity of motor conductors: 3 at 5% x 00% of ull load urrent (L) Standard & ertification uilt to NP 20 (latest edition) Mark: Various N, & directives and standards nclosure Protection Rating P55 ccessories ottom entry gland plate Paint Specifications Red RL3002 Powder coating lossy textured finish isconnecting Means mergency Start andle Locked Rotor lectrical Readings Pressure Readings solating switch and circuit breaker: solating switch rated not less than 5% of motor full load current ircuit breaker continuous rating not less than 5% of motor full load current Overcurrent sensing non-thermal type, magnetic only nstantaneous trip setting of not more than 20 times the motor full load current ndividual operating handles lange mounted Pull and latch activation ntegrated limit switch cross the line start (direct on line) Operate shunt trip to open circuit breaker actory set at 00% of motor full load current Trip between and 20 seconds Voltage phase to phase (normal power) mperage of each phase when motor is running ontinuous system pressure display ut-in and ut-out pressure settings ebruary 20 2

3 Submittal ata Sheet Model lectric ire Pump ontroller Pressure and vent recorder Pressure Sensing Visual ndications & larms Remote larm ontacts ViZiTouch Light Operator nterface Operation Pressure readings with date stamp vent recording with date stamp Under regular maintained operation, events can be stored in memory for up to 5 years. ata viewable on operator interface display screen Pressure transducer for fresh water application Pressure sensing line connection /2 emale NPT rain connection 3/ Rated for 0-500PS working pressure (calibrated at 0-300psi) xternally mounted with protective cover Power available Phase reversal Motor run Pump room alarm Motor trouble Phase loss Low water level SPT--250V. Power available Phase reversal Motor run ommon pump room alarm Overvoltage Undervoltage Phase unbalance ommon motor trouble Overcurrent Undercurrent ail to start mbedded microcomputer with software PL logic 4.2 color touch screen (M technology) Upgradable software xpandable storage Multi-language Start on pressure drop utomatic Start Remote start signal from automatic device Start pushbutton Run test pushbutton Manual Start eluge valve start Remote start from manual device Manual with Stop pushbutton Stopping utomatic after expiration of minimum run timer ** Timers ctuation Mode Phase unbalance Locked rotor ail to start Low discharge pressure Pump on demand/utomatic start mergency start Manual start ield djustable & Visual ountdown Visual ndication eluge valve start Remote automatic start Remote manual start Overcurrent Undercurrent Undervoltage Overvoltage Minimum run timer **(off delay) Sequential start timer (on delay) Manual test timer Pressure Non-pressure utomatic Non-automatic ** an only be used if approved by the J ebruary 20 3

4 Submittal ata Sheet Model lectric ire Pump ontroller Options nti-condensation heater & thermostat L0 Other language and nglish (bilingual) L02 rench L03 Spanish L04 erman L05 talian L0 Polish L07 Romanian L0 ungarian L09 Slovak L0 roatian L zech L Portuguese L3 utch L Russian L5 Turkish L Swedish L7 ulgarian L Thai L9 ndonesian L20 Slovenian L2 anish L22 reek L23 rabic L24 ebrew L25 hinese Note: Options chosen from this page are not electrically represented on the wiring schematics in this submittal package. ebruary 20 4

5 Submittal ata Sheet Model lectric ire Pump ontroller ViZiTouch Light Operator nterface Power on L 2 - olor touch screen 3 - larm L 4 - OM page button 5 - LRM page button - ONURTON page button 7 - STORY page button - US port 9 - STRT button 0- ontextual navigation pad - STOP button - RUN TST button ebruary 20 5

6 lectric ire Pump ontroller ull Voltage / cross The Line imension 5 [27"] Model: uilt to the latest edition of the NP 20 standard RV. 0. RST SSU Optional SRPTON /MM/YY 04/02/ rawing No / X-S-ViZi 00 [ "] 9 [ 3 4 "] 200 ["] 25 ["] See Notes 02 [3 2 "] PT Power Table 700 [27 2 "] Voltage Min Max 37 [5 4 "] O P 40 P 4 kw 22 kw 5 P 0 P Sensing Line onnection /2 ".NPT oor Swing 73 [29"] kw 45 kw 5 [3 4 "] 23 ["] 225 [ 3 4 "] 3 [5 3 4 "] 20 ["] 0 [ 4 "] 40 [ 2 "] 0 [4 3 4 "] Notes: - P55 assembly. - ll dimensions are in millimeters [nches]. - enter of ViZiTouch screen: 52 [22-4"] from bottom. - Paint: textured red RL ottom conduit entrance through removable gland plate recommended. - Use watertight conduit and connectors only. - Protect equipment against drilling chips. - rawing for information only. Manufacturer reserves the right to modify this drawing without notice. ontact manufacturer for "s uilt" drawing. PROJTON opyright 20 Tornatech nc.ll right reserved. This drawing and the information contained or depicted herein are the sole property of Tornatech nc. opies are communicated to the recipient in strict confidence and may not be retransmitted, published, reproduced, copied or used in any manner, including as the basis for the manufacture or sale of any products, without the express prior written consent of Tornatech nc.

7 P lectric ire Pump ontroller ull Voltage / cross The Line Wiring schematic S L3 L2 L Model: uilt to the latest edition of the NP 20 standard Optional RV. SRPTON /MM/YY 0. RST SSU 0/02/ rawing No. J P RS45 -WS500 / X-S-ViZi To /O lectric oard 4 To J45 ST (P.2 / 4) 2 J J3 VZTOU Main oard P2 P (P.2 / 5) J 3L3 To J57 (P.2/) 24V J3 N OM 0 OM OM 2 OM 3 J OM 4 OM 5 OM OM 7 3L3 7 T2 T3 R4 lack 9 White lack 7 White To J7 (P.2/) (P.2/) T 4 lack 5 White ** T T2 M T3 ** ontact closes when emergency starts is in "ON" position. Note: - rawing for information only. Manufacturer reserves the right to modify this drawing without notice. ontact manufacturer for "s uilt" drawing opyright 20 Tornatech nc.ll right reserved. This drawing and the information contained or depicted herein are the sole property of Tornatech nc. opies are communicated to the recipient in strict confidence and may not be retransmitted, published, reproduced, copied or used in any manner, including as the basis for the manufacture or sale of any products, without the express prior written consent of Tornatech nc.

8 P lectric ire Pump ontroller ull Voltage / cross The Line Wiring schematic Model: uilt to the latest edition of the NP 20 standard Optional RV. SRPTON /MM/YY 0. RST SSU 0/02/ rawing No. -WS500 / X-S-ViZi R4 R4- R4-2 PT Red White lack To ST (P. / ) XTR X 2 24V X2 9 To T (P. / 2) 5 4 3L3 To -2-3 (P. / ) To R4 (P. / 2) J J3 J3 4-N 3-N PT-N PT2-N J J5 J J7 SV N J43 N J45 ST2 N + J44 R N J47 L J J J J J57 J9 (ail Safe) /O lectric oard J40 J42 J37 J39 J4 T T2 T3 T4 T5 To ViZiTouch Main oard (P. / ) P J Motor Run Power vailable Phase Reversal Pump Room larm Motor Trouble LS** LS- LS-2 Remote Manual Start Lockout Remote uto Start J* eluge Valve J2* Water Reservoir Low * Remove this jumper to use this feature ** ontact closes when emergency start is in "ON" position opyright 20 Tornatech nc.ll right reserved. This drawing and the information contained or depicted herein are the sole property of Tornatech nc. opies are communicated to the recipient in strict confidence and may not be retransmitted, published, reproduced, copied or used in any manner, including as the basis for the manufacture or sale of any products, without the express prior written consent of Tornatech nc.

9 P lectric ire Pump ontroller ull Voltage / cross The Line Terminals diagram N ield onnections Normal Power onnections T T2 T3 M N round S L L2 L3 ncoming Power Model: uilt to the latest edition of the NP 20 standard ield onnections Remote Manual Start Terminals Wire Size: - 24 W 0.5 Nm Lockout Remote uto Start eluge Valve Water Reservoir Low /O lectric oard *J *J J25 ontrol Terminal Strip Optional RV. SRPTON /MM/YY 0. RST SSU 0/02/ rawing No. Motor Run Power vailable (ail Safe) Phase Reversal Pump Room larm Motor Trouble Normally losed loses to alarm Normally losed Normally losed Normally losed larm ontacts Terminals Wire Size: - 24 W 0.5 Nm loses to alarm Normally losed loses to alarm loses to alarm loses to alarm -WS500 / /O lectric oard J9 - J9 - J9 - J40 - J40 - J40 - J9 - J9 - J9 - J9 - J9 - J9 - J9 - J9 - J9 - X-S-ViZi T T2 T3 T4 * Remove this jumper to use this feature opyright 20 Tornatech nc.ll right reserved. This drawing and the information contained or depicted herein are the sole property of Tornatech nc. opies are communicated to the recipient in strict confidence and may not be retransmitted, published, reproduced, copied or used in any manner, including as the basis for the manufacture or sale of any products, without the express prior written consent of Tornatech nc.

Model GPY + GPU Full Service Reduced Voltage Wye-delta Open Electric Fire Pump Controller with Automatic Power Transfer Switch

Model GPY + GPU Full Service Reduced Voltage Wye-delta Open Electric Fire Pump Controller with Automatic Power Transfer Switch Project: ustomer: Engineer: Pump Manufacturer: Submittal Document Model GPY + GPU Full Service uced Wye-delta Open Electric Fire Pump ontroller ontents: Data Sheets Dimensional Data Wiring Schematics Field

More information

Model GPR + GPU Full Service Reduced Voltage Autotransformer Electric Fire Pump Controller with Automatic Power Transfer Switch

Model GPR + GPU Full Service Reduced Voltage Autotransformer Electric Fire Pump Controller with Automatic Power Transfer Switch Project: ustomer: Engineer: Pump Manufacturer: Submittal Document Model GPR + GPU Full Service uced Autotransformer Electric Fire Pump ontroller ontents: Data Sheets Dimensional Data Wiring Schematics

More information

QO and QOU Miniature Circuit Breakers QOU Miniature Circuit Breakers

QO and QOU Miniature Circuit Breakers QOU Miniature Circuit Breakers QO and Miniature ircuit reakers Miniature ircuit reakers lass 720 / Refer to atalog 0730T9801 Low mpere Miniature ircuit reakers unit mount miniature circuit breakers (cable-in/cable-out) are ideal for

More information

QO and QOU Miniature Circuit Breakers QO Circuit Breaker Accessories

QO and QOU Miniature Circuit Breakers QO Circuit Breaker Accessories QO and Miniature ircuit reakers QO ircuit reaker ccessories lass 1130 / Refer to atalog 0730T9801 IRUIT RKRS ccessories for Use with QO and QO Miniature ircuit reakers Handle ttachments escription at.

More information

E C N A A F -

E C N A A F - 33-52 NA ontactors & Starters 3-Phase agnetic Starters nclosed Freedom Line January 1 Vol. 2, Ref. No. [0068] Selection Table 33-102. NA Freedom Line nclosed ontrol ing System 33 esign Page N - NA 33-40

More information

For the most up-to-date information

For the most up-to-date information www.square.com or the most up-to-date information Thermal-magnetic Molded ase ircuit reakers, 2 mpere rame lass 5,, 734, 8 IL3 JL 3-pole circuit breaker -frame, Thermal-magnetic ( Vac) mpere Magnetic Trip

More information

28.1. NEMA Contactors and Starters. Contents. Contactors Non-Reversing and Reversing. Freedom Series. Product Description

28.1. NEMA Contactors and Starters. Contents. Contactors Non-Reversing and Reversing. Freedom Series. Product Description .1 NM ontactors and Starters Non- and ontactors ontactors Non- and Product escription Non- ontactors are most commonly used to switch motor loads in applications where running overcurrent protection is

More information

Spring Return and Double Acting Pneumatic Quarter- Turn Actuators For Output Torques to 13,444 lb.in.

Spring Return and Double Acting Pneumatic Quarter- Turn Actuators For Output Torques to 13,444 lb.in. Spring Return and ouble cting Pneumatic Quarter- Turn ctuators For Output Torques to 13,444 lb.in. Features and benefits ompact rack and pinion design utilizes the whole piston area to develop output torque.

More information

XT SERIES Jockey Pump Controllers Features

XT SERIES Jockey Pump Controllers Features XT SERIES Jockey Pump Controllers Features XT Series Jockey Pump Controllers March 2012 1-1 XT Power Controls The XT Series of Jockey Pump Controllers incorporate Eaton s XT Power Controls which are designed

More information

SureFire SLR Lubricator

SureFire SLR Lubricator Sureire SR ubricator utomatic, Oil eneral he Sureire SR automatic lubricator is a robust and durable pump that can handle oil and soft greases. Its compact size is designed to fit your space requirements

More information

Selection Information Molded Case Circuit Breakers

Selection Information Molded Case Circuit Breakers Selection Information Molded ase ircuit reakers lass 500, 600, 800 PowerPact 150 H-rame PowerPact 250 J-rame Trip Version Trip Version ircuit reaker Type H H HJ HL HR J J JJ JL JR Number of 2, 3 2, 3 2,

More information

Disconnect Switch and Circuit Breaker Mechanism Specifications Bulletin Number 1494

Disconnect Switch and Circuit Breaker Mechanism Specifications Bulletin Number 1494 Technical ata isconnect Switch and ircuit reaker Mechanism Specifications ulletin Number 1494 Topic Page 1494U isconnect Switch Specifications 2 1494, 1494F, 1494G, 1494R, 1494V isconnect Switch Specifications

More information

Selection Information Molded Case Circuit Breakers

Selection Information Molded Case Circuit Breakers Selection Information Molded ase ircuit reakers lass 500, 600, 800 100 rame 100 -rame IRUIT RKRS 3 ircuit reaker Type (240 V) H Hb H I Y Number of 1, 2, 3 1 2, 3 1 1 2, 3 2, 3 1 urrent Range 15 100 15

More information

.1 NM ontactors and Starters Product Overview starters and contactors feature a compact, space-saving design, using state-of-the-art technology and th

.1 NM ontactors and Starters Product Overview starters and contactors feature a compact, space-saving design, using state-of-the-art technology and th NM ontactors and Starters NM N16N0 NM Size 1 Starter.1 Product Overview.............................................. Features, enefits and Functions.................................. Standards and ertifications......................................

More information

NEMA Contactors and Starters

NEMA Contactors and Starters NM ontactors and Starters NM N16N0 NM Size 1 Starter NM Size 1 ontactor.1 Product Overview.............................................. 242 Features, enefits and Functions..................................

More information

Open, NEMA Type 1, 3R, 4/4X and 12. Auxiliary Contacts

Open, NEMA Type 1, 3R, 4/4X and 12. Auxiliary Contacts 0.- Motor Starters & ontactors Low Voltage Lighting ontactors lectrically eld N January 00 Sheet 18 0 1 7 8 0 1 7 8 0 N-Open (L0-nclosed) 0 mpere 0 mpere Product escription Lighting ontactors are designed

More information

Nickel Plated Brass 2-way Full Port Ball Valve FEATURES

Nickel Plated Brass 2-way Full Port Ball Valve FEATURES -800-899-0553 0 Series Nickel Plated rass -way ull Port all Valve The 0 is a full port, nickel plated brass, NPT threaded end actuated ball valve. t can be equipped with a manual handle or with direct

More information

Quick quarter-turn rotation. High cycle stem design. Integrated mounting pad for actuators. Compact assembly. Complete line of accessories.

Quick quarter-turn rotation. High cycle stem design. Integrated mounting pad for actuators. Compact assembly. Complete line of accessories. 36 Series Stainless Steel 2-way ull Port all Valve The 36 is a full port, 36 stainless steel, 3 piece ball valve. t is available with threaded ends (36N), socket weld ends (36S), or quick clamp ends with

More information

NEMA Contactors & Starters A200

NEMA Contactors & Starters A200 March 007 NM ontactors & Starters 00 ontactors Non-reversing and Reversing -7 ontents escription Page ontactors Non-reversing and Reversing............ -7 Product escription Sizes 00 4............ -7 Product

More information

FE Frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FE160 FE250. Protection. Trip Unit. Rated Current (A)

FE Frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FE160 FE250. Protection. Trip Unit. Rated Current (A) rame reaking capacities Icu 0/415V in k eff. Type V 36 N H L 1 1 Protection LTM Line thermal magnetic protection LTM Selective thermal magnetic protection TM enerator thermal magnetic protection Mag reak

More information

FD frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FD160. Trip Unit. Rated Current (A)

FD frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FD160. Trip Unit. Rated Current (A) frame reaking capacities 2, 3 and 4 pole types Single pole types Icu 0/415V in k eff. Type 18 S 36 N H L 1 Icu 230/2V in k eff. N H Protection Order odes LTM Line thermal magnetic protection LTM Selective

More information

NEMA Contactors and Starters

NEMA Contactors and Starters NM ontactors and Starters NM N16DN0 NM Size 1 Starter.1 Freedom Series Product Overview........................................ Features, enefits and Functions............................ Standards and

More information

Adams. Progressive. Description. Typical system layout using Pneumatic Pump for grease - with monitoring. Typical system

Adams. Progressive. Description. Typical system layout using Pneumatic Pump for grease - with monitoring. Typical system 45 P rogressive systems can be used for oil or grease lubrication when it is required to provide a positive displacement with visual or electrical monitoring. ll outlets can be checked by one indicator

More information

H81xx. H81xx Energy Meter. quick install POWER MONITORING INSTALLATION GUIDE. Installer s Specifications

H81xx. H81xx Energy Meter. quick install POWER MONITORING INSTALLATION GUIDE. Installer s Specifications POWR MOITORIG ISTLLTIO GUI H81xx H81xx nergy Meter H06 (optional mounting bracket) Installer s Specifications Insulation lass 600V Sample Rate 1280 Hz Internal Isolation 2500V Operating Temp. Range 0 to

More information

26 Series assuredautomation.com. Stainless Steel 2-way Full Port Ball Valve (Cutaway View) PARTS & FEATURES

26 Series assuredautomation.com. Stainless Steel 2-way Full Port Ball Valve (Cutaway View) PARTS & FEATURES 6 Series Stainless Steel -way ull Port all Valve The 6 is a full port, 36 stainless steel, NPT threaded end automated ball valve. t can be equipped with a manual handle or with direct mount pneumatic or

More information

411BAM Battery Auctioneering Module

411BAM Battery Auctioneering Module uctioneering Module Introduction The is designed to act as a central component of a small system. It can measure the voltage and current of two separate banks, up to 100. It provides three outputs, auctioneered

More information

Linear Position Technology EZ-track

Linear Position Technology EZ-track Rugged Rod Style Housings: Transducers designed to survive in harsh industrial environments to reduce downtime on the plant floor. The R10 housing, sensing rod and components are designed and constructed

More information

503 Series Solenoid Pilot Actuated Valves

503 Series Solenoid Pilot Actuated Valves Solenoid Pilot ctuated Valves Offered by: Specialists in Valves, ontrols, Pneumatics, Fluid Measurement Phone: (203) 261-6711 www.okcautomation.com 5 Ported, 2 and 3 position, 4-way, Spool & Sleeve and

More information

FD frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FD63 FD160. Trip Unit. Rated Current (A) FD63 (2,3 & 4 pole)

FD frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FD63 FD160. Trip Unit. Rated Current (A) FD63 (2,3 & 4 pole) frame reaking capacities 2, 3 and types Single pole types Icu 0/415V in k eff. Type 18 18 S 36 36 N H L 1 1 Icu 2/2V in k eff. N H Protection LTM Line thermal magnetic protection LTM Selective thermal

More information

Numatics, Inc. is a leading manufacturer of pneumatic products and motion control products.

Numatics, Inc. is a leading manufacturer of pneumatic products and motion control products. Numatics, Inc. is a leading manufacturer of pneumatic products and motion control products. Our broad spectrum of standard, custom developed products and application components have made a significant

More information

DA/CL 74C Gear Motor and PCB

DA/CL 74C Gear Motor and PCB /L 74 Gear Motor and P Technical User Guide English: For other language variants of this document we refer to: Español: Para otras variantes del idioma de este documento, visite: Français: Pour les versions

More information

EDB-EPD, EGB-EPD and EJB-EPD (Equipment Protection Device) Circuit Breakers for Ground Fault Protection in NF Panelboards

EDB-EPD, EGB-EPD and EJB-EPD (Equipment Protection Device) Circuit Breakers for Ground Fault Protection in NF Panelboards -P, -P and J-P (quipment Protection evice) ircuit reakers for round ault Protection in N Panelboards Square -P, -P and J-P (quipment Protection evice) ircuit reakers are 1-pole thermal-magnetic circuit

More information

Sanitary Clamp, Full Port, 3-way Ball Valves (3-A approved) FEATURES. FLOW PLANS L Port

Sanitary Clamp, Full Port, 3-way Ball Valves (3-A approved) FEATURES. FLOW PLANS L Port 30 Series Sanitary lamp, ull Port, 3-way all Valves (3- approved) 3- pproved for use in food processing and dairy applications Valve Pressure / Temperature 1000 The ssured utomation 30 Series 3- approved,

More information

D I D /240 I. D x /240 I D / x x /24 I. D x /120

D I D /240 I. D x /240 I D / x x /24 I. D x /120 ndustrial ontrol Transformers lass 9070 www.square.com or the most up-to-date information The T units are designed for the global market and are the best choice when size and cost are of concern. This

More information

501 SERIES. 501 Series Directional Control Valve Platform. Featuring Higher Flow in a Compact Valve Package. Commissioning Capabilities

501 SERIES. 501 Series Directional Control Valve Platform. Featuring Higher Flow in a Compact Valve Package. Commissioning Capabilities 501 Series irectional ontrol Valve Platform Featuring Higher Flow in a ompact Valve Package ommissioning apabilities Solenoid air pilot actuated Low wattage.8 wall for application solenoids Polarity insensitive

More information

GE Consumer & Industrial. M-PACT New Air Circuit Breaker A

GE Consumer & Industrial. M-PACT New Air Circuit Breaker A GE onsumer & Industrial M-PT New ir ircuit reaker 400-4000 M-PT M-PT ir ircuit reaker 400-4000 1 ir circuit breakers 400-4000.4 Fixed ircuit reaker.6 Withdrawable ircuit reaker.7 haracteristics.9 State

More information

June 2005 CN35 Electrically Held Vol. 2, Ref. No. [0494]

June 2005 CN35 Electrically Held Vol. 2, Ref. No. [0494] 7-2 Lighting ontactors Open ontrol June 2005 N5 lectrically Held Vol. 2, Ref. No. [09] ontents eatures Instructional Leaflets 7 escription Page lectrically Held Product escription....... 7-2 pplication

More information

Submittal. THBP Horizontal Low Profile Plenum Return FCU-THBP Top View (Drain Pan Omitted) Bottom View. Front View.

Submittal. THBP Horizontal Low Profile Plenum Return FCU-THBP Top View (Drain Pan Omitted) Bottom View. Front View. U-THBP-.0 03-0-8 THBP Horizontal Low Profile Plenum Return Top View (rain Pan Omitted) Bottom View ront View Left hand unit shown. ll dimensions are inches [millimeters]. Side View [8] 26 [6] [06] [270]

More information

Solenoid Pilot Actuated Valves

Solenoid Pilot Actuated Valves Solenoid Pilot ctuated Valves 02 Series irectional ontrol Valve www.asco.com Table of ontents 02 Series Features and enefits Performance ata How to Order Sandwich Option Kit 9 Speed ontrol Kit 9 Shut

More information

Project: Customer: Engineer: Pump Manufacturer: Drawing Submittal Package Model GPL Limited Service Full Voltage Across the Line Start Electric Pump Controller Contents: Submittal Data Sheets Dimensional

More information

F6100HD, 4, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

F6100HD, 4, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc 6100H, 4, 2-Way utterfly Valve Resilient Seat, 304 Stainless Steel isc pplication Valve is designed f use in SI flanged piping systems to meet the needs of bi-directional high flow HV hydronic applications

More information

F6125HD, 5, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

F6125HD, 5, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc 6125H, 5, 2-Way utterfly Valve Resilient Seat, 304 Stainless Steel isc pplication Valve is designed for use in NSI flanged piping systems to meet the needs of bi-directional high flow HV hydronic applications

More information

Matic TM. Data sheet Sheet No.: Rev. A EL-O-MATIC ACTUATORS WITH ASCO SOLENOID VALVES Date: November /2 NC 5/2

Matic TM. Data sheet Sheet No.: Rev. A EL-O-MATIC ACTUATORS WITH ASCO SOLENOID VALVES Date: November /2 NC 5/2 ata sheet Sheet No.:.06. Rev. -O-MTI TUTORS WITH SO SOLNOI VLVS ate: November 009 Selector plate for / - / function lectrical entry Pg 9 8 ir entry G/" Speed control (optional) 7 Speed control (optional)

More information

MANUAL ELECTRIC FIRE PUMP CONTROLLERS METRON SERIES M450

MANUAL ELECTRIC FIRE PUMP CONTROLLERS METRON SERIES M450 MANUAL ELECTRIC FIRE PUMP CONTROLLERS METRON SERIES M450 TABLE OF CONTENTS PART I GENERAL DESCRIPTION... PAGE 2 PART II FUNCTIONS... PAGE 2 PART III INSTALLATION... PAGE 3 PART IV INITIAL INSTALLATION

More information

H81xx Energy Meter. H81xx NOTICE DANGER INSTALLATION GUIDE QUICK INSTALL POWER MONITORING

H81xx Energy Meter. H81xx NOTICE DANGER INSTALLATION GUIDE QUICK INSTALL POWER MONITORING POWR MOITORIG nergy Meter H06 (optional mounting bracket for small, medium, and large Ts) GR HZR O LTRI SHOK, XPLOSIO, OR R LSH ollow safe electrical work practices. See P 70 in the US, or applicable local

More information

Level Measurement Point level measurement - Rotation paddle switches

Level Measurement Point level measurement - Rotation paddle switches Siemens 017 SITRNS LPS00 Overview SITRNS LPS00 is a rotary paddle switch for point level and material detection in bulk solids. enefits Proven paddle switch technology for bulk solids High integrity mechanical

More information

F6100HD, 4, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

F6100HD, 4, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc 6100H, 4, 2-Way utterfly Valve Resilient Seat, 304 Stainless Steel isc pplication Valve is designed for use in NSI flanged piping systems to meet the needs of bi-directional high flow HV hydronic applications

More information

Control and Automation

Control and Automation onsumer & ndustrial Power Protection ontrol and utomation or industrial applications.03 imagination at work Plug-in relays and uxiliary contactors Motor protection devices ontactors and Thermal overload

More information

From the Hyson family of higher force gas springs

From the Hyson family of higher force gas springs rom the Hyson family of higher force gas springs Same force and diameter as T3 Series S-4 (7/16-20) port for use with standard full size hoses ive sizes from 1000 to 9500 Up to 21,400 lbs. contact force

More information

Level Measurement Point level measurement - Vibrating switches

Level Measurement Point level measurement - Vibrating switches Siemens G 2018 SITRNS LVS200 Overview SITRNS LVS200 is a vibrating point level switch for high, low, or demand level detection of bulk solids. enefits High resistance to mechanical forces Strong vibration

More information

BOILER CONTROLS. Hot Water Boilers. How to Select Low Water Cut-Offs for Hot Water Boilers

BOILER CONTROLS. Hot Water Boilers. How to Select Low Water Cut-Offs for Hot Water Boilers OILR ONTROLS ot Water oilers OILR ONTROLS Mconnell & Miller Low Water cut-offs are specially designed to protect hot water boilers from the hazards of a low water condition. In operation they will interrupt

More information

Definite Purpose Control. Product Focus

Definite Purpose Control. Product Focus Product Focus Innovation in Eaton s utler-hammer efinite Purpose (P) ontactors are designed to improve control of refrigeration, air conditioning, ventilation and resistance heating applications. The

More information

PNEUMATIC RACK AND PINION ACTUATORS. Advanced torque to size ratio

PNEUMATIC RACK AND PINION ACTUATORS. Advanced torque to size ratio PNUMTI RK N PINION TUTORS dvanced torque to size ratio eatures: Pneumatic Rack and Pinion ctuators 90 ctuation for -way valves (Straight & ngle) 180 ctuation for -way (T-type) valves ctuators comply with

More information

Z % OUTSIDE AIR (US & CANADA) Z RECIRCULATION (US) Z PROCESS HEATER (US AND CANADA)

Z % OUTSIDE AIR (US & CANADA) Z RECIRCULATION (US) Z PROCESS HEATER (US AND CANADA) Z83.4 100% OUTI IR (U & ) Z83.18 - RIRULTIO (U) Z83.25 - RO TR (U ) TT112 & TT115 orizontal Model L L R Y J IR MR URR / LOWR TIO ILTR TIO ILT MR ILT OO WIT IRR M X W I V Z Z T K V Q R R 2 IMIO MOL J K

More information

THERMAL-MAGNETIC/MAGNETIC ONLY MOLDED CASE CIRCUIT BREAKERS

THERMAL-MAGNETIC/MAGNETIC ONLY MOLDED CASE CIRCUIT BREAKERS THRML-MNTI/MNTI ONLY MOL S IRUIT RKRS INTROUTION SPTMR, 1991 LSS IV xchange of permanent trip circuit breakers (K, L, M or N) furnished in lieu of circuit breakers specified with interchangeable trip.

More information

Starters. NEMA Contactors & NEMA Contactors & Starters Contents

Starters. NEMA Contactors & NEMA Contactors & Starters Contents January Vol., Ref. No. [007] - NM ontactors & Starters ontents Page Freedom Line Product Family Overview......................................... - ontactors Non-reversing and Reversing.........................

More information

THERMAL-MAGNETIC/MAGNETIC ONLY MOLDED CASE CIRCUIT BREAKERS

THERMAL-MAGNETIC/MAGNETIC ONLY MOLDED CASE CIRCUIT BREAKERS THRML-MNTI/MNTI ONLY MOL S IRUIT RKRS INTROUTION SPTMR, 1991 LSS IV xchange of permanent trip circuit breakers (K, L, M or N) furnished in lieu of circuit breakers specified with interchangeable trip.

More information

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions...

Circuit Breakers. Switching & Controls.  Selection Guide NC1V Series Dimensions... Switching & ontrols Selection Guide... 1028 1V Series... 1029 Dimensions... 1035 www.ide.com/circuitbreaker ircuit Breakers Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal

More information

BUILT FOR WORK SEWAGE AND WASTEWATER PUMPS

BUILT FOR WORK SEWAGE AND WASTEWATER PUMPS UILT OR WORK SWG N WSTWTR PUMPS lectric Submersible Pumps ccessories UILT OR WORK SWG N WSTWTR PUMPS lectric Submersible Pumps ccessories Simple esign, xtreme Quality. [ Submersible utter Pump: Series]

More information

Efficor. Most reliable technology. High installation benefits. Best in class. Standards. Approvals. Global contactors. Intro. J/X New A.

Efficor. Most reliable technology. High installation benefits. Best in class. Standards. Approvals. Global contactors. Intro. J/X New A. Most reliable technology igh installation benefits lobal contactors Standard materials for food & beverage and transportation purposes complying the latest rail standards ighest reliable product performance

More information

F-Frame. January 2001 Vol. 1, Ref. No. [0586] Discount Symbol... CB-2. For more information contact Cutler-Hammer at:

F-Frame. January 2001 Vol. 1, Ref. No. [0586] Discount Symbol... CB-2. For more information contact Cutler-Hammer at: -0 Motor ircuit Protectors Vol. 1, Ref. No. [058] -rame Table -188. V A, V NMA Starter Size ont. Amps am Motor ull Load urrent Amps MP Trip MP Table -188. V A, V (ontinued) NMA Starter Size ont. Amps am

More information

Air Handlers Series. Direct-Fired Heating Pressurization. Dimension and Selection Guide

Air Handlers Series. Direct-Fired Heating Pressurization. Dimension and Selection Guide 2000-Series ir andlers irect-ired eating Pressurization imension and Selection uide 1.800.536.3461 www.rapidengineering.com N: 100% OUTSI IR ONLY 2000-Series Selection uide IMPORTNT NOTS: ll information

More information

Spiraflo Steam flowmeters

Spiraflo Steam flowmeters Spiraflo Steam flowmeters Using a Spiraflo steam meter from Spirax Sarco will enable you to measure steam use accurately under all load conditions. It will provide vital information on usage and associated

More information

Instrument Ball Valves

Instrument Ball Valves www.swagelok.com Instrument all s 40 Series On-off, switching, and crossover flow paths Working pressures up to 3000 psig (206 bar) Temperatures from 50 to 150 (10 to 65 ) Low-temperature service option

More information

GE 8000-Line Motor Control Centers Mains, Feeders, Incoming Lines C-1

GE 8000-Line Motor Control Centers Mains, Feeders, Incoming Lines C-1 GE 8000-Line -1 Mains, coming Lines MAINS GENERAL Main units consist of an externally operable circuit disconnect, either a fusible switch or a circuit breaker. Sizes by ampere rating, short-circuit rating,

More information

Rescue Reels. HazMat Situations Vehicular Extrications At-the-scene Emergencies Breathing and Utility Air Applications Distributed by REEL TECH

Rescue Reels. HazMat Situations Vehicular Extrications At-the-scene Emergencies Breathing and Utility Air Applications Distributed by REEL TECH Rescue Reels azmat Situations Vehicular xtrications t-the-scene mergencies reathing and Utility ir pplications istributed by RL T ou an t uy etter Reel. amily owned and operated since 1933 RSU RLS Table

More information

Automatic Heat/Cool Changeover

Automatic Heat/Cool Changeover -0 odels -000/000/00/00 he 000 panel provides intelligent control of forced air zoning systems with up to eight zones using motorized dampers and practically any off-the-shelf heat/cool thermostat can

More information

APCO CVS-6000/6000A SWING CHECK VALVES

APCO CVS-6000/6000A SWING CHECK VALVES ULLTIN 00/579 JUN 2016 PO S-00/00 SING K LS PO S Swing heck s are recommended for clean and dirty services such as ater, Sewage or Industrial applications. S-00/00 Swing heck s are a heavily constructed,

More information

ELECTRIC BOLT LOCKS AR-1203A SERIES. (Fail-Safe)(Power to Lock) INSTALLATION INSTRUCTIONS. RoHS. AR-1203A Ver Patent No.

ELECTRIC BOLT LOCKS AR-1203A SERIES. (Fail-Safe)(Power to Lock) INSTALLATION INSTRUCTIONS. RoHS. AR-1203A Ver Patent No. ELETRI OLT LOKS R-1203 SERIES (Fail-Safe)(Power to Lock) INSTLLTI INSTRUTIS RoHS R-1203 Ver.02-0913 Patent No. M 329084 ontents I. Order Information... 1 II. Features & Functions... 1 III. dditional Functions...

More information

General Specifications

General Specifications Slides Rotaries Programmable Illuminated P Pushbuttons Supplement ccessories Indicators eneral Specifications lectrical apacity Resistive Load: 0 @ 5V, @ 50V, or @ 0V Inductive Load: 5 @ 5V (P.. @.0) Other

More information

Commercial & Industrial Ventilation Complete Line of Sustainable Products

Commercial & Industrial Ventilation Complete Line of Sustainable Products ommercia l Kitchen Ventilation ommercial & Industrial Ventilation omplete Line of Sustainable Products 919.88.4 800.334.956 919.88.504 (fax) www.captiveaire.com ontents entrifugal Upblast xhaust Fans N-F

More information

DMC-500 TM. DC Motor Drive Control. Operation / Installation Manual Manual Part Number: S8M5003 Date: August 11, Computer Weld Technology, Inc.

DMC-500 TM. DC Motor Drive Control. Operation / Installation Manual Manual Part Number: S8M5003 Date: August 11, Computer Weld Technology, Inc. omputer Weld Technology, Inc. 070 Old ammel N Houston Rd. Houston, TX 77086 Telephone: (7) 46-8 Fax: (7) 46-50 DM-500 TM D Motor Drive ontrol Operation / Installation Manual Manual Part Number: S8M500

More information

DIESEL Engine Fire Pump Controllers Features

DIESEL Engine Fire Pump Controllers Features 1-1 Printer / Recorder The industrial grade thermal printer is housed in a rugged steel enclosure within the controller. The on/off switch, feed and reset buttons are front accessible. A bi-color status

More information

THERMAL-MAGNETIC/MAGNETIC ONLY MOLDED CASE CIRCUIT BREAKERS

THERMAL-MAGNETIC/MAGNETIC ONLY MOLDED CASE CIRCUIT BREAKERS THRML-MNTI/MNTI ONLY MOL S IRUIT RKRS INTROUTION SPTMR, 1991 LSS IV xchange of permanent trip circuit breakers (K, L, M or N) furnished in lieu of circuit breakers specified with interchangeable trip.

More information

BUILT FOR WORK. w w w. t s u r u m i c a n a d a. c o m

BUILT FOR WORK. w w w. t s u r u m i c a n a d a. c o m S W G & W S T W T R P U M P S UILT OR WORK l e c t r i c S u b m e r s i b l e P u m p s c c e s s o r i e s w w w. t s u r u m i c a n a d a. c o m Simple esign, xtreme Quality. [Submersible utter Pump:

More information

Rescue Reels. HazMat Situations Vehicular Extrications At-the-scene Emergencies Breathing and Utility Air Applications

Rescue Reels. HazMat Situations Vehicular Extrications At-the-scene Emergencies Breathing and Utility Air Applications Rescue Reels azmat Situations Vehicular xtrications t-the-scene mergencies reathing and Utility ir pplications ou an t uy etter Reel. amily owned and operated since 1933 RSU RLS Table of ontents Reel Type

More information

EIC combination motor starters

EIC combination motor starters pplications: Harsh and hazardous motor control environments, including refineries, chemical and petrochemical plants, corrosive process facilities, food and beverage, marine and mining cross-the-line starting

More information

Constant torque, Constant power, Torque boost Six selectable pre-set patterns

Constant torque, Constant power, Torque boost Six selectable pre-set patterns VT20 Micro variable speed drives Single-phase or three-phase digital inverters for controlling the speed of three-phase induction motors from 02 to 22kW uilt-in keypad and display P20 or P65 protection

More information

General Specifications

General Specifications Series M eneral Specifications Miniature Supplement ccessories Indicators Touch Tilt Tactiles Slides Rotaries Keylocks Programmable Illuminated PB Pushbuttons Rockers Electrical apacity (Resistive Load)

More information

FH Fan-Coil Units Low-Profile, Horizontal

FH Fan-Coil Units Low-Profile, Horizontal FH Fan-oil Units Low-Profile, Horizontal FH Fan-oil Units: Innovative design simplifies installation and service Owners HRI Standard 440-certifi cation ensures exacting performance. The FH fan-coil unit

More information

Contactors & Starters. Definite Purpose. Definite Purpose Contactors & Starters C-1. Contents

Contactors & Starters. Definite Purpose. Definite Purpose Contactors & Starters C-1. Contents Definite Purpose ontactors & Starters - July 007 Definite Purpose ontactors & Starters ontents Description Page Product Family Overview pplication Description........................................ -

More information

Class 0734, 0500 / Refer to Catalogs: 0734CT0201, 0500CT9702. PowerPact G-Frame 3P 100 A Thermal-Magnetic Circuit Breaker (600Y/347 Vac)

Class 0734, 0500 / Refer to Catalogs: 0734CT0201, 0500CT9702. PowerPact G-Frame 3P 100 A Thermal-Magnetic Circuit Breaker (600Y/347 Vac) MINITUR N MOL S IRUIT RKRS PowerPact ircuit reaker JL 3P ircuit reaker QL 2P 0 250 QL 3P 0 250 Tale.46: mpere - and Q-rame ircuit reakers lass 034, 0500 / Refer to atalogs: 034T0201, 0500T902 PowerPact

More information

Updated: October 2012

Updated: October 2012 T: (630) 794-5100 EMERGENCY POWER FUEL SYSTEMS Earthsafe Systems, Inc. 7320 S. Madison Willowbrook, IL 60527 F: (630) 794-5106 info@earthsafe.com www.earthsafe.com Updated: October 2012 The information

More information

Symbol Key NOTES: E C-1* T T T. Termovar Option 2

Symbol Key NOTES: E C-1* T T T. Termovar Option 2 ioeat US 4 ritton Lane Lyme, N 03768 rawn by: TSP hecked by: ioeat US Piping Layout oncept iagram Wood oiler (Up to 140,000tuh) with ossil uel oiler and STSS ladder Type Tank ate W NO RV 9-04-008 STSS1

More information

R1000 Series Relays. Features and Benefits. Enclosed Relay Contacts Delivers maximum durability and extends life; inhibits corrosion and dust build-up

R1000 Series Relays. Features and Benefits. Enclosed Relay Contacts Delivers maximum durability and extends life; inhibits corrosion and dust build-up Master atalog 125 s and ontactors Section R Product Bulletin R1000 Issue Date 0493 R1000 Series s The R1000 Series s switch line voltage devices from low voltage controllers. Plug-in DPDT relays and snap-in

More information

Motor Control. Contactors C 25 D N A 2 15 A A CATALOG SELECTION. Definite Purpose Contactors Catalog Numbering System. Contactors

Motor Control. Contactors C 25 D N A 2 15 A A CATALOG SELECTION. Definite Purpose Contactors Catalog Numbering System. Contactors Selection ompact Definite Purpose Motor ontrol TLOG SELETION Definite Purpose ing System 2 D N 2 Model = ontactor = Three-Phase Starter = Single-Phase Starter Type 2 = Non-Reversing 27 = Non-Reversing

More information

FK Frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FK800 FK1250 FK1600. Protection. Rated Current (A) Trip Unit FK800 FK1250 FK1600

FK Frame. Breaking capacities. Icu 400/415V AC in ka eff. Type FK800 FK1250 FK1600. Protection. Rated Current (A) Trip Unit FK800 FK1250 FK1600 K rame reaking capacities Icu 400/415V in k eff. Type V K K K N H 80 80 80 L 100 100 Protection Order odes Trip Unit K K K Rated urrent () 630 LTM Mag reak SMR1e (1) SMR1s (1) SMR1g (1) LTM Line thermal

More information

B352, 3-Way, Characterized Control Valve Stainless Steel Ball and Stem

B352, 3-Way, Characterized Control Valve Stainless Steel Ball and Stem 352, 3-Way, haracterized ontrol Valve Stainless Steel all and Stem pplication This valve is typically used in air handling units on heating or cooling coils, and fan coil unit heating or cooling coils.

More information

Submittal. RBHR Horizontal Low Profile Concealed with Plenum FCU-RBHR Top View (Drain Pan Omitted) Bottom View. Front View.

Submittal. RBHR Horizontal Low Profile Concealed with Plenum FCU-RBHR Top View (Drain Pan Omitted) Bottom View. Front View. Horizontal Low Profile oncealed with Plenum FU-RBHR-1.0 05-11-17 Top View (rain Pan Omitted) Left hand unit shown. ll dimensions are inches [millimeters]. [8] 26 [6] 21 [533] 27 [686] 31 [787] 41 [1041]

More information

Filled System Thermometers

Filled System Thermometers illed System Thermometers Model N & NR Mechanical Thermometers ata sheet : ST/2012 The Rototherm range of filled system thermometers offer tough yet accurate instruments with rigid stems for direct mounting

More information

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories Switching & ontrols Selection Guide... 922 1V Series... 923 Dimensions... 929 Accessories... 932 ircuit Breakers Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal Blocks

More information

Endura AZ20 oxygen monitor Combustion gas analysis. Superior technology and quality from the world leader in oxygen measurement

Endura AZ20 oxygen monitor Combustion gas analysis. Superior technology and quality from the world leader in oxygen measurement Data sheet DS/AZ EN Rev. G Endura AZ oxygen monitor Superior technology and quality from the world leader in oxygen measurement Advanced design and precision manufacturing robust, long-life probe for process

More information

PATTERSON PUMP COMPANY

PATTERSON PUMP COMPANY PATTERSON PUMP COMPANY A Gorman Rupp Company JOCKEY PUMP CONTROLLERS UL508 LISTED ETL LISTED FEB 013 Patterson Jockey Pump controllers are built to NEMA industrial standards and are UL508 listed and ETL

More information

L2 FWD REV L1 L2 L1 L2 L3 FWD REV (L.H. UNIT) (R.H. UNIT) HIGH LOW HIGH LOW

L2 FWD REV L1 L2 L1 L2 L3 FWD REV (L.H. UNIT) (R.H. UNIT) HIGH LOW HIGH LOW Manual ontrol lass - RV, SMF, MMS 0/0/ lass - RV Signaling ontact for lass - RV Typical lass SMF RV9-M Typical MMS Reversing Manual Starter and Manual Motor Starting Switches -Speed Manual Motor Starting

More information

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work Section 16435 - SWITCHBOARDS Introduction Part 1 - General Related Work Section 16070 Seismic Anchorage and Restraint Section 16075 Electrical Identification Section 16080 Power Distribution Acceptance

More information

RVS. Pedestals. Intro. Stainless steel pedestals. Applications. Features. Standards. Advantages C.20

RVS. Pedestals. Intro. Stainless steel pedestals. Applications. Features. Standards. Advantages C.20 Pedestals ntro pplications - nergy distribution - Recreation grounds - able television - Traffic regulation & signalling - Telecommunications - Market connections - vent connections - as distribution Standards

More information

PVL Series. Solenoid & Remote Pilot Operated 1/8" & 1/4" Valves. Section C. C59

PVL Series. Solenoid & Remote Pilot Operated 1/8 & 1/4 Valves. Section C.   C59 Series Solenoid & Remote Pilot Operated /8" & /4" Valves Section Moduflex www.parker.com/pneu/pvl asic Valve unctions...60 Stacking pplications...6-62 eatures ( & )...63 ommon Part Numbers-Stacking ( &

More information

Bettis EHO Electro-Hydraulic Operator

Bettis EHO Electro-Hydraulic Operator ettis Electro-Hydraulic Operator The ettis is a self-contained, quarter-turn, valve actuator that combines proven technologies from Emerson s Valve utomation. The actuator has been designed for critical

More information

RV SYSDrive AC Inverters

RV SYSDrive AC Inverters 7160_Omron 3/31/04 4:38 PM Page 1 OMRON IM ONTROLS, IN. RV SYSrive Inverters High-Value, 4-in-1 Inverter Solutions for General-Purpose & High-End pplications 7160_Omron 3/31/04 4:38 PM Page RV Inverter

More information

EEA & EEB Series. UL Recognized CSA Certified VDE Approved EEA2 / EEB2

EEA & EEB Series. UL Recognized CSA Certified VDE Approved EEA2 / EEB2 atalog: 16541 Issue ate: 6.11 Including the S/S and H/H Models ost-effective MI Power Inlet Filter UL Recognized S ertified V pproved 2 / 2 1 / 1 P / P Series ompact single stage MI filter with I 63-1

More information