1 전자개폐기 Order Code List of AC Technical Information Control Relay Accessories Thermal Overload Relay ~ ~ ~ ~ ~ 107 BEST QUALITY & BEST PRICE 70 Best Quality & Best Price The Highest Quality Products Information 71

2 MCCB ELCB Circuit Protector DC Contactor Relay Order Code List of AC TMC9 TMC12 TMC18 TMC 22 A Rated (AC440) 구분 POWNIX 9 7A 85 80A 12 9A A 18 13A A 22 20A A 32 25A A 40 32A 50 48A 65 65A 75 75A A - 1a1b AC220V A S H Standard Economy Hoist (KSC4504) TMCSeries TMC 9 TMC12 TMC18 Aux. Contact(Standard) 1a1b 1a1b 1a1b Single Phase 220~220V 2.2kW11A 2.7kW 13A 3.7kW 18A 380~440V 2.7kW 7A 4kW 9A 5.5kW 13A 500~550V 2.7kW 6A 5.5kW 9A 5.5kW 13A 200~220V 1.5kW 8A 2.2kW 11A 3.7kW 18A 380~440V 2.2kW 6A 4kW 9A 4kW 9A 110V 0.4kW 11A 0.5kW 13A 0.75kW 18A 220V 0.8kW 11A 1kW 13A 1.5kW 18A Main Contact - Standard(3a) 2P Single Phase Aux. Contact 1a1b 2a2b 3a Coil Voltage AC110V AC220V 80V AC440V Resistive DC1 2P series 3P series 110V 6A 10A 13A 220V 3A 7A 8A 110V 8A 12A 18A 220V 8A 12A 18A Ith (AC1) 25A 25A 25A Control Relay DAR 4 AC220 (IEC 60947) 200~240V 2.5kW 11A 3.5kW 13A 4.5kW 18A 380~440V 4kW 9A 5.5kW 12A 7.5kW 18A 500~550V 4kW 7A 7.5kW 12A 7.5kW 13A 690V 4kW 5A 7.5kW 9A 7.5kW 9A Control Relay Control Relay Aux. Contact / No. of Contact 4 4 Contacts 6 6 Contacts 8 8 Contacts Coil Voltage AC 24~550V Manufacturer: Dong-A Electric Endurance (x10,000 times) Aux. Contact Mounting Method Electrical Mechanical 2,500 2,500 2,500 Side-On DAV2b DAV2b DAV2b Head-On DAV2,4 DAV2,4 DAV2,4 Screw and DIN-Rail Dimension(mm) (W H D) DAU Auxiliary Unit Auxiliary Unit 100 No. of Contacts Mounting Position Applied MC 1 2 Contacts Side 2 2 Contacts Head TMC9~ Contacts Head Contacts Side TMC100~150 Mounting Dimension(mm) (W D) 30~35 48~59,35 60 Contactor Switch Thermal Overload Relay With DC-operated Coil TMD-9 TMD-12 TMD-18 Reversing TMC9R TMC12R TMC18R Standard TMS-9 TMS-12 TMS-18 Phase Loss Protection TMS-9K TMC12K TMS-18K Standard DTH-22 DTH-22 DTH-22 Phase Loss Protection DTH-22 DTH-22 DTH-22 3 elements DTH-22/3 DTH-22/3 DTH-22/3 Manufacturer: Dong-A Electric 72 Best Quality & Best Price The Highest Quality Products Information 73

3 MCCB ELCB Circuit Protector DC Contactor Relay List of AC TMC22 List of AC TMC22S TMC32S TMC40S TMCSeries TMC 22 Aux. Contact(Standard) 1a1b 2a2b TMCSeries TMC22S TMC32S TMC40S Aux. Contact(Standard) (KSC4504) Single Phase 220~220V 4kW 20A 4kW 20A 380~440V 7.5kW 20A 7.5kW 20A 500~550V 7.5kW 17A 7.5kW 17A 200~220V 3.7kW 18A 3.7kW 18A 380~440V 5.5kW 13A 5.5kW 13A 110V 0.9kW 20A 0.9kW 20A 220V 1.8kW 20A 1.8kW 20A (KSC4504) Single Phase 220~220V 4kW 20A 5.5kW 26A 7.5kW 35A 380~440V 7.5kW 20A 11kW 25A 15kW 32A 500~550V 7.5kW 17A 11kW 20A 15kW 26A 200~220V 3.7kW 18A 4.5kW 20A 5.5kW 25A 380~440V 5.5kW 13A 7.5kW 17A 11kW 24A 110V 0.9kW 20A 1.2kW 26A 1.7kW 35A 220V 1.8kW 20A - - Resistive DC1 2P series 3P series 110V 15A 15A 220V 12A 12A 110V 20A 20A 220V 20A 20A Resistive DC1 2P series 3P series 110V 15A 25A 25A 220V 12A 12A 12A 110V 20A 25A 35A 220V 20A 22A 30A Ith (AC1) 40A 40A Ith (AC1) 40A 50A 60A (IEC 60947) 200~240V 5.5kW 22A 5.5kW 22A 380~440V 11kW 22A 11kW 22A 500~550V 15kW 22A 15kW 22A 690V 15kW 18A 15kW 18A (IEC 60947) 200~240V 5.5kW 22A 7.5kW 32A 11kW 40A 380~440V 11kW 22A 15kW 32A 18.5kW 40A 500~550V 15kW 22A 18.5kW 28A 22kW 32A 690V 15kW 18A 18.5kW 20A 22kW 23A Endurance (x10,000 times) Electrical Mechanical 2,500 2,500 Endurance (x10,000 times) Electrical Mechanical 2,500 2,500 2,500 Aux. Contact Side-On DAV2b DAV2b Head-On DAV2,4 DAV2,4 Aux. Contact Side-On DAV2b DAV2b DAV2b Head-On DAV2,4 DAV2,4 DAV2,4 Mounting Method Screw and DIN-Rail Mounting Method Screw and DIN-Rail Dimension(mm) (W H D) Mounting Dimension(mm) (W D) 30~35 48~59,35 60 Dimension(mm) (W H D) Mounting Dimension(mm) (W D) 30~35 48~59,35 60 Contactor Switch With DC-operated Coil TMD-22 TMD-22 Reversing TMC22R TMC22R Standard TMS-22 TMS-22 Phase Loss Protection TMC22K TMC22K Contactor Switch With DC-operated Coil Reversing Standard Phase Loss Protection Thermal Overload Relay Standard DTH-22 DTH-22 Phase Loss Protection DTH-22 DTH-22 3 elements DTH-22/3 DTH-22/3 Thermal Overload Relay Standard Phase Loss Protection elements Best Quality & Best Price The Highest Quality Products Information 75

4 MCCB ELCB Circuit Protector DC Contactor Relay List of AC TMC32 TMC40 TMC48 List of AC TMC50 TMC65 TMC75 TMC85 TMCSeries TMC32 TMC40 TMC48 Aux. Contact(Standard) 2a2b 2a2b 2a2b TMCSeries TMC50 TMC65 TMC75 TMC85 Aux. Contact(Standard) 2a2b 2a2b 2a2b 2a2b (KSC4504) Single Phase 220~220V 5.5kW 26A 7.5kW 35A 7.5kW 35A 380~440V 11kW 25A 15kW 32A 15kW 32A 500~550V 11kW 20A 15kW 26A 15kW 26A 200~220V 4.5kW 20A 5.5kW 25A 5.5kW 25A 380~440V 7.5kW 17A 11kW 24A 11kW 24A 110V 1.2kW 26A 1.7kW 35A 1.7kW 35A 220V (KSC4504) Single Phase 220~220V 11kW 50A 15kW 65A 18.5kW 75A 19kW 80A 380~440V 22kW 48A 30kW 65A 37kW 75A 37kW 80A 500~550V 22kW 38A 37kW 60A 37kW 64A 45kW 75A 200~220V 7.5kW 35A 11kW 50A 13kW 55A 15kW 65A 380~440V 15kW 32A 22kW 47A 25kW 52A 30kW 62A 110V V Resistive DC1 2P series 3P series 110V 25A 25A 25A 220V 12A 12A 12A 110V 25A 35A 35A 220V 22A 30A 30A Resistive DC1 2P series 3P series 110V 35A 35A 50A 50A 220V 15A 15A 20A 20A 110V 50A 65A 70A 80A 220V 40A 50A 55A 60A Ith (AC1) 50A 60A 60A Ith (AC1) 80A 100A 110A 135A (IEC 60947) 200~240V 7.5kW 32A 11kW 40A 11kW 40A 380~440V 15kW 32A 18.5kW 40A 18.5kW 40A 500~550V 18.5kW 28A 22kW 32A 22kW 32A 690V 18.5kW 20A 22kW 23A 22kW 23A (IEC 60947) 200~240V 15kW 55A 18.5kW 65A 22kW 75A 25kW 85A 380~440V 22kW 50A 30kW 65A 37kW 75A 45kW 85A 500~550V 30kW 43A 33kW 60A 37kW 64A 45kW 75A 690V 30kW 28A 33kW 35A 37kW 42A 45kW 45A Endurance (x10,000 times) Electrical Mechanical 1,500 1,500 1,500 Endurance (x10,000 times) Electrical Mechanical 1,000 1,000 1,000 1,000 Aux. Contact Side-On DAV2b DAV2b DAV2b Head-On DAV2,4 DAV2,4 DAV2,4 Aux. Contact Side-On DAV2b DAV2b DAV2b DAV2b Head-On DAV2,4 DAV2,4 DAV2,4 DAV2,4 Mounting Method Screw and DIN-Rail Mounting Method Screw and DIN-Rail Dimension(mm) (W H D) Mounting Dimension(mm) (W D) 30~35 48~59,35 60 Dimension(mm) (W H D) Mounting Dimension(mm) (W D) ~60, Contactor Switch With DC-operated Coil TMD-32 TMD-40 TMD-48 Reversing TMC32R TMC40R TMC48R Standard TMS-32 TMS-40 TMS-48 Phase Loss Protection TMC32K TMC40K TMC48K Contactor Switch With DC-operated Coil TMD-50 TMD-65 TMD-75 TMD-85 Reversing TMC50R TMC65R TMC75R TMC85R Standard TMS-50 TMS-65 TMS-75 TMS-85 Phase Loss Protection TMC50K TMC65K TMC75K TMC85K Thermal Overload Relay Standard DTH-40 DTH-40 DTH-40 Phase Loss Protection DTH-40 DTH-40 DTH-40 3 elements DTH-40/3 DTH-40/3 DTH-40/3 Thermal Overload Relay Standard DTH-85 DTH-85 DTH-85 DTH-85 Phase Loss Protection DTH-85 DTH-85 DTH-85 DTH-85 3 elements DTH-85/3 DTH-85/3 DTH-85/3 DTH-85/3 76 Best Quality & Best Price The Highest Quality Products Information 77

5 MCCB ELCB Circuit Protector DC Contactor Relay List of AC TMC100 TMC125 List of AC TMC150 TMC180 TMC220 TMCSeries TMC100 TMC125 Aux. Contact(Standard) 2a2b 2a2b TMCSeries TMC150 TMC180 TMC220 Aux. Contact(Standard) 2a2b 2a2b 2a 2a2b 2b (KSC4504) Single Phase 220~220V 25kW 100A 30kW 125A 380~440V 50kW 100A 60kW 120A 500~550V 55kW 80A 60kW 90A 200~220V 19kW 80A 22kW 93A 380~440V 37kW 75A 45kW 90A 110V V - - (KSC4504) Single Phase 220~220V 37kW 150A 45kW 180A 55kW 230A 380~440V 75kW 150A 90kW 180A 110kW 230A 500~550V 90kW 140A 110kW 180A 132kW 200A 200~220V 30kW 125A 37kW 150A 45kW 180A 380~440V 55kW 110A 75kW 150A 90kW 180A 110V V Resistive DC1 2P series 3P series 110V 80A 80A 220V 50A 50A 110V 100A 100A 220V 80A 80A Resistive DC1 2P series 3P series 110V 100A 150A 150A 220V 100A 150A 150A 110V 150A 180A 220A 220V 150A 180A 220A Ith (AC1) 150A 150A Ith (AC1) 200A 230A 260A (IEC 60947) 200~240V 30kW 105A 35kW 125A 380~440V 55kW 105A 60kW 120A 500~550V 55kW 85A 60kW 90A 690V 55kW 65A 60kW 70A (IEC 60947) 200~240V 45kW 150A 55kW 180A 75kW 250A 380~440V 75kW 150A 90kW 180A 132kW 250A 500~550V 90kW 140A 110kW 180A 132kW 200A 690V 90kW 100A 110kW 120A 132kw 150A Endurance (x10,000 times) Electrical Mechanical Endurance (x10,000 times) Electrical Mechanical Aux. Contact Side-On - - Head-On - - Aux. Contact Side-On Head-On Mounting Method Screw Only Mounting Method Screw Only Dimension(mm) (W H D) Mounting Dimension(mm) (W D) 88~90 92~125 Dimension(mm) (W H D) Mounting Dimension(mm) (W D) Contactor Switch With DC-operated Coil - - Reversing - - Standard TMS-100 TMS-125 Phase Loss Protection TMC100K TMC125K Contactor Switch With DC-operated Coil Reversing Standard TMS-150 TMS-180 TMS-220 Phase Loss Protection TMC150K TMC180K TMC220K Thermal Overload Relay Standard DTH-150 DTH-150 Phase Loss Protection DTH-150 DTH elements DTH-150/3 DTH-150/3 Thermal Overload Relay Standard DTH-150 DTH-180 DTH-220 Phase Loss Protection DTH-150 DTH-180 DTH elements DTH-150/3 DTH-180/3 DTH-220/3 78 Best Quality & Best Price The Highest Quality Products Information 79

6 MCCB ELCB Circuit Protector DC Contactor Relay Rated Capacity Rated Capacity (AC4) Inching & Plugging Magnetic Contactor squirrel cage () Rated (Kw) woundrotor (AC2B) inching plugging(ac4) Resistive (AC1) 200~220V 380~440V 500~550V 200~220V 380~440V 500~550V 200~220V 380~440V 500~550V 500~550V TMC TMC TMC TMC TMC22S TMC32S TMC40S Subject Rated Capacity at Inching(kW) Rated Capacity at Plugging(kW) Voltage 200~220V 380~440V 200~220V 380~440V Inching % 10% 50% 100% 10% 50% 100% Plugging 100% Electrical Endurance [x10,000 operations] TMC TMC TMC TMC TMC TMC TMC TMC TMC TMC TMC TMC TMC TMC22S TMC32S TMC TMC Rated Operating Magnetic Contactor squirrel cage () (A) woundrotor (AC2B) inching plugging(ac4) 200~220V 380~440V 500~550V 200~220V 380~440V 200~220V 400~440V Rated Thermal current Ith (AC1) TMC TMC TMC TMC TMC22S TMC32S TMC40S TMC TMC TMC TMC TMC TMC TMC TMC TMC TMC40S TMC TMC TMC TMC TMC TMC TMC TMC TMC TMC TMC TMC TMC No. of Inching Operations Note 1. Inching(%) = No. of Standard Duty + No. of Inching operations 100% Note 2. The limit of on/off operation in inching is below 10 based on 1 operation/sec. 80 Best Quality & Best Price The Highest Quality Products Information 81

7 MCCB ELCB Circuit Protector DC Contactor Relay DC s(rated DC ) Auxiliary Contact s TMC9 TMC12 TMC18 TMC22 TMC22S TMC32S TMC40S TMC32 TMC40 TMC50 TMC65 TMC75 TMC85 TMC100 TMC125 TMC150 TMC180 TMC220 No. of Contact in Series DC2, DC4 Rated Operating (A) DC (L/R=15ms) DC1 Rated Operating (A) DC (L/R=1ms) DC11 Rated Operating (A) DC (L/R=100ms) 24V 48V 110V 220V 24V 48V 110V 220V 24V 48V 110V 220V 2Pole Pole Pole Pole Pole Pole Pole Pole Pole Pole Pole Pole Pole Pole Pole Pole Pole Pole Pole Pole Pole Pole Pole Pole Pole Pole Pole Pole Pole Pole Pole Pole Pole Pole Pole Pole DC Class 2 and DC Class 4 are the examples stipulated in KS C 4504 and JEM 1188 applied for the starting and stopping of a DC shunt motor and a DC series motor, respectively. 2. DC Class 11 and DC Class 1 are the examples stipulated in KS C 4504 and JEM 1188 applied for an inductive load (time constant 100mS) and a resistive load, respectively. 3. For DC 2 and DC 4 Class, the closed circuit capacity is the four times of the value in the table and its number of repetition is 100 times, while the interrupting capacity is the four times of the values in the table and its number of repetition is 25 times. 4. For the methods of 2 poles in series and 3 poles in series, refer to the drawing shown on the right. 5. The electrical life span is 500,000 times. TMC 9~85 TMC 100~220 Contact Arrangement AC Operation AC15(11) (Inductive on AC) Characteristics of AC Coil DC13(11) (Inductive on DC) AC12(13) (Resistive on AC) TMC9~85 Electromagnet Capacity[VA] Thermal Dissipation Operating Voltage[V] Inrush Holding [W] Pick-up Drop-out Coil [ ma ] DC12(14) (Resistive on DC) 110V 220V 440V 550V 24V 48V 110V 220V 110V 220V 440V 550V 24V 48V 110V 220V TMC100~220 Operating Time[ ms ] Coil ON Main Contact ON AC220V 60Hz Coil OFF Main Contact OFF TMC9,12,18,22,22S,32S,40S ~ ~ ~18 7~12 TMC32, ~ ~ ~19 8~13 TMC50,65,75, ~ ~ ~25 8~15 Rated Thermal Ith (AC1) Standard Contacts Option TMC9 ~ 22 1a1b 4a, 3a1b, 2a2b, 1a3b / 2a, 1a1b / 1a1b TMC32 ~ 85 2a2b 4a, 3a1b, 2a2b, 1a3b / 2a, 1a1b TMC100 ~ 220 2a2b - Designation Voltage Range Designation Voltage Range AC 24V AC 110V AC 220V AC 380V AC 480V 24V 50Hz 24V 60Hz 100V 50Hz 100~110V 60Hz 200V 50Hz 200~220V 60Hz 346~380V 50Hz 380V 60Hz 415~440V 50Hz 460~480V 60Hz AC48V AC120V AC240V AC440V 48V 50Hz 48V 60Hz 110~120V 50Hz 115~120V 60Hz 220~240V 50Hz 230~240V 60Hz 380~400V 50Hz 400~440V 60Hz Designation AC 24V AC 110V AC 220V AC 380V Voltage Range 100~127V 50Hz 100~127V 60Hz 200~240V 50Hz 200~240V 60Hz 380~440V 50Hz 380~440V 60Hz 346~380V 50Hz 380V 60Hz 1.Designation is the symbol for ordering. Please check designation of Voltage range before ordering. 2. Among the control coil ratings for TMC 9~40, Designation AC 220V is recommended for 220V 60 Hz, Designation AC 440V for 380V 50 Hz, Designation AC 240V for 220V 50 Hz, and Designation AC 480V for 415V 50 Hz, respectively. 3. Up to the ambient temperature of 40oC, the coils operate normally within the range of 85 to 110% of the rated operating voltage. 4. If the voltage of the control circuit deviates from the allowable range of the rated operating voltage, degradation of insulation is promoted and the mechanical durability deteriorated. 5. The coil marked with a symbol is a special specification. Please consult the maker before ordering. TMC100, ~ ~ ~35 90~120 TMC150,180, ~ ~ ~35 90~ Best Quality & Best Price The Highest Quality Products Information 83

8 MCCB ELCB Circuit Protector DC Contactor Relay Classes by Breaking and ON/OFF Capacity Performance s are classified as below by the breaking and on/off capacity with reference to the domestic standard, KS and the foreign standards such as IEC, BS, VDE and UL. Classification Class Operation Test According to IEC60947 Making Making.Breaking KS, JEM, JIS IEC, BS, VDE KS, JEM, JIS IEC, BS, VDE Voltage Factor AC1 Non-inductive resistive load on/off 1.5le 1.1Ee le 1.05Ue le 1.1Ee le 1.05Ue 0.8 AC2B Wound rotor motor starting, stopping 4le 1.1Ee 0.65 " " " " 1.1Ee 0.65 " " " AC2 Wound rotor motor plugging, inching 4le 1.1Ee le 0.05Ue le 1.1Ee le 1.05Ue 0.65 cage motor starting, stopping 10le 1.1Ee le 1.05Ue 45( 100A) 8le 1.1Ee le 1.05Ue 45( 100A) AC4 cage motor plugging, inching 12le 1.1Ee le 1.05Ue 35( >100A ) 10le 1.1Ee le 1.05Ue 35(>100A) Class Magnetic Contactor Voltage Factor Voltage Factor Voltage Operating Cycles 100Cycle 50Cycle 25Cycle 50Cycle 3phase squirrel cage motor() KS, JEM, JIS IEC, BS, VDE Making Breaking Making Breaking Voltage Factor 3phase wound rotor motor(ac2b) 3phase squirrel cage motor inching, plugging(ac4) 200~240V 380~440V 500~550V 200~240V 380~440V 500~550V 200~240V 380~440V kw A kw A kw A kw A kw A kw A kw A kw A A TMC TMC TMC TMC TMC22S TMC32S TMC40S TMC TMC TMC TMC TMC TMC TMC TMC TMC TMC TMC Voltage Factor Voltage AC1 Non-inductive resistive load on/off le Ee 0.95 le Ee 0.95 le 105 Ue 0.8 AC2 Wound rotor motor plugging, inching 2.5le Ee le Ee le 105 Ue 0.65 Factor cage motor starting, stopping 6le Ee 0.35 le 0.17Ee le 105 Ue 0.45 ( 100A) AC4 cage motor plugging, inching 6le Ee le Ee 0.35 le 105 Ue 0.35 (>100A) Factor Remark IEC947-4 Standard On-Time 0.05sec 6,000cycles Rated Thermal Ith(AC1) TMC9 TMC12 TMC18 TMC22 TMC22S TMC32S TMC40S TMC32 TMC40 TMC50 TMC65 TMC75 TMC85 TMC100 TMC125 TMC150 TMC180 TMC220 Test Duty of the Electrical Endurance() Test Duty of the Electronical Endurance(AC4) 6Im Rated Voltage (V) Rated (A) Making Voltage E 6Im Breaking Voltage E/6 Im Making Breaking Capacity(A) Cycles per hour Endurance( 10,000 operations) Making Breaking Mechanical Electronical() 6Im Making Voltage E 6Im Breaking Voltage E/6 Im Performance Indication 1,800 2, ,800 2, ,800 2, ,800 2, ,800 2, ,800 2, ,800 2, ,800 1, ,800 1, ,200 1, ,200 1, ,200 1, ,200 1, , , , , , Auxiliary Contact 형명 AC15(11)(AC Coil ) DC13(11)(DC Coil ) AC12(13)(AC Resistive ) DC12(14)(DC Resistive ) Rated Thermal 110V 220V 440V 550V 24V 48V 110V 220V 110V 220V 440V 550V 24V 48V 110V 220V (Ith) TMC9~ TMC100~ *Minimum current and voltage used are 24V and 10 ma. 0.75sec 2sec Im E : Rated Voltage Im : Rated 1. The number of cycles for making capacity is 100 and for breaking capacity, Making and Breaking Capacity for 13times of rated current are 100times for making and 1time for breaking. 6sec E : Rated Voltage Im : Rated 3. Electrical Endurance of AC4 is 30,000 operations. 84 Best Quality & Best Price The Highest Quality Products Information 85

9 MCCB ELCB Circuit Protector DC Contactor Relay Graph for Electrical Endurance(TMC9 ~ 85) 3Ø AC200~220V 3Ø 80~440V for Star-Delta Starting There are two different methods of Star-delta starting of a motor; one using three magnetic contactor and the other using two. Between the contactor for the Star circuit (MCS or MCS1) and that for the delta circuit (MCD), it is indispensable to establish electrical interlock between the two contactor. The three contactor method is generally preferred, since no voltage is applied to the motor winding while the motor is not running and thus destruction of insulation by leakage current can be suppressed. The two contactor method is economical, but voltage is applied to the motor winding while the motor is not running, and thus it is not suitable for application such as fire fighting equipment whose downtime is very long., Voltage and Torque of the for Star-Delta Starting Starting For Starting (Star ) For Operation (Delta ) Method Torque Full Contact Voltage Full Contact Voltage Contact Voltage Direct 6lm 1.5T 6lm Em lm lm Em Star-Delta 2lm 0.5T 2lm Em lm lm Em Im: load current to the motor of delta wiring, Em : line-to-line voltage, T : rated torque (Change in torque is an estimated value.) MCM MCD MCS RT OCR MC for Source MC for Operation MC for Starting Timer Overcurrent Relay Graph for Electrical Endurance(TMC100 ~ 220) Example of a wiring diagram for Star-Delta Starting Example of a wiring diagram for Star-Delta Starting 3Ø AC200~220V 3Ø 80~440V Device (3 contactors) Star-Delta Starting Device Device (2 contactors) 220 ~ 220V 380 ~ 480V Capacity(kW) Starting(MCS) Operation(MCD) Source(MCM) Starting(MCS) Operation(MCD) Source(MCM) 5.5 TMC22 TMC22 TMC22 TMC22 TMC22 TMC TMC22 TMC32 TMC32 TMC22 TMC22 TMC TMC32 TMC40 TMC40 TMC22 TMC22 TMC TMC32 TMC50 TMC50 TMC22 TMC32 TMC TMC40 TMC50 TMC50 TMC22 TMC40 TMC TMC40 TMC65 TMC65 TMC32 TMC40 TMC TMC50 TMC85 TMC85 TMC40 TMC50 TMC TMC65 TMC100 TMC100 TMC40 TMC65 TMC TMC65 TMC125 TMC125 TMC40 TMC65 TMC TMC85 TMC150 TMC150 TMC50 TMC85 TMC TMC100 TMC180 TMC180 TMC65 TMC100 TMC TMC125 TMC220 TMC220 TMC85 TMC125 TMC TMC TMC100 TMC150 TMC TMC TMC100 TMC180 TMC TMC TMC125 TMC220 TMC TMC The above values may vary depending on the class of the motor and the manufacturer. These are reference values based on class standard squirrel cage type or class AC2 wound-rotor type. 2. The starting of the motor has been based on 10 seconds or less. 3. In case of a load to which a phase-lead capacitor has been applied, the in-rush current to the capacitor should be considered for selection. 86 Best Quality & Best Price The Highest Quality Products Information 87

10 MCCB ELCB Circuit Protector DC Contactor Relay for Resistive s Mounting and Operational Environment ㆍ As resistive loads such as electric furnaces and heaters demonstrate low in-rush current and high power factor, a magnetic contactor can be applied for a relatively high current compared with motor loads. of magnetic contactor for resistive loads is tabulated as follows. Usage Class Interrupting Capacity of Closed Circuit of for Resistive s Electrical On-Off Durability Making Breaking Making Breaking On-Off of AC Resistive AC1 1.5le, 1.1Ee, cosø le, 1.1Ee, cosø 0.95 le, Ee, cosø 0.95 le, Ee, cosø 0.95 On-Off DC Resistive DC1 1.1le, 1.1Ee, L/R 1ms 1.1le, 1.1Ee, L/R 1ms le, Ee, L/R 1ms le, Ee, L/R 1ms AC1 Rated Operating (A) Capacity AC1(kW) 3 Phase Single Phase Class 1 Rated Operating (3 Poles in Parallel, A) (Remark 1) DC Class 1 Rated Operating 3Poles in Series (2 Poles in Parallel, A)(Remark2) 200~ ~ ~ ~ ~ ~ ~110 48V 110V 220V TMC (10) 8(6) 8(3) TMC (12) 12(10) 12(7) Operational Environment 1) Ambient Temp. : Ref. Temp. 20, -25 ~+40 (No more than 35 of average temp. per 1day 24hours) 2) Max. Temp. in the panel : 55 (Enclosed type : Ambient Temp. 40 ) 3) Relative Humidity : 45~85% RH 4) Altitude : Lower than 2,000m 5) Vibration Resistance : 10~55Hz 2g 6) Impact Resistance : 5g 7) Storage Temp. : -30 ~65 (No frozen place) Mounting 1) Install the contactor at a dry location with the minimum vibration. 2) Vertical mounting is standard for mounting direction, but it can be normally used up to ±30 to the angle direction as shown in the picture below. 3) In case of transverse or horizontal mounting, reduction of endurance and deterioration of various performance may take place compared with standard mounting. 4) Reversed mounting may cause noise from the contactor. Install the contactor after verification of the power source side and the load side without fail. TMC (18) 18(13) 18(8) TMC (20) 20(15) 20(10) TMC (25) 25(25) 22(12) TMC (35) 35(25) 30(12) TMC (40) 50(35) 40(15) TMC (40) 65(35) 50(15) TMC (65) 75(50) 55(20) TMC (65) 80(50) 60(20) TMC (93) 93(80) 70(50) TMC (100) 100(80) 80(50) TMC (120) 150(100) 150(100) TMC (180) 180(150) 180(150) TMC (180) 220(150) 220(150) Standard Mounting Transverse Mounting 1) In case of connecting 3-poles in parallel, use a terminal plate as in the picture shown below to homogenize temperature rise of each pole. 2) In case of connecting 2 poles or 3 poles inseries, connect the load on the opposite side of the power source as in the picture shown below. 3) Electrical life span is 500,000 times. terminal plate 2Poles in Series 3Poles in Series Horizontal Mounting Reversed Mounting 88 Best Quality & Best Price The Highest Quality Products Information 89

11 MCCB ELCB Circuit Protector DC Contactor Relay Connectable Wire and Tightening Torque for Lighting s Main Circuit TerminalScrew SizeofConnectableWire( mm2 ) SolderlessTerminal( mm2 ) Tightening Torque(kgf ㆍcm ) Line (Magnetic Contactor) (Overload Relay) Line (Magnetic Contactor) (Overload Relay) Line () (Overload Relay) Line (Magnetic Contactor) (Overload Relay) TMC9 M4 M4 1.25~ ~5.5(ø1.6~2.6) ~5.5-4(ø1.6~2.6) ~ TMC12 M4 M4 1.25~ ~5.5(ø1.6~2.6) ~5.5-4(ø1.6~2.6) ~ TMC18 M4 M4 1.25~ ~5.5(ø1.6~2.6) ~5.5-4(ø1.6~2.6) ~ TMC22 M4 M4 1.25~ ~5.5(ø1.6~2.6) ~5.5-4(ø1.6~2.6) ~ TMC32 M5 M5 2~14 2~14(ø1.6~3.6) ~14-5(ø1.6~3.6) ~ TMC40 M5 M5 2~14 2~14(ø1.6~3.6) ~14-5(ø1.6~3.6) ~ TMC50 M6 M6 2~22 2~ ~ ~ TMC65 M8 M8 2~38 2~ ~ ~ TMC75 M8 M8 2~38 2~ ~ ~ TMC85 M8 M8 2~38 2~ ~ ~ TMC100 M8 M8 2~60 2~60 2.8~ ~ TMC125 M8 M8 2~60 2~60 2-8~ ~ TMC150 M10 M10 2~150 2~ ~ ~ For Lighting loads, electrical endurance or the number of switching can be short/small except some special cases. Therefore, the selection points are, 1 The total of the input current to the loads should not exceed the rated current of the magnetic contactor. 2 Inrush current by starting should remain below the open circuit current capacity of the magnetic contactor. Incandescent Lamps Because the filament of an incandescent lamp is low especially at ambient temperature, theoretically the inrush current at the moment of lighting the lamp is 3 to16 times of the rated current, but the impedance of the circuit and the self-heating of the lamp limit the inrush current to 7 to 10times of the rated current in practical conditions. The example of characteristics from the moment of lighting the lamp to the point being stable current is shown in the graph in the right. The magnetic contactor applied for incandescent lamps should be selected with a transient current of this level taken into consideration, and the rated current to the incandescent lamps should be the same as or lower than the rated current. Number of incandescent lamps that can be switched Source Voltage Consumption 100V(Unit: Lamps) Inrush current characteristics at the moment of lighting the lamp for 100V, 40W, 60W of general lighting 200V(Unit: Lamps) 100W 150W 200W 250W 300W 500W 1000W 1500W 100W 150W 200W 250W 300W 500W 1000W 1500W TMC TMC TMC TMC TMC TMC TMC TMC TMC180 M10 M10 2~150 2~ ~ ~ TMC220 M10 M10 2~150 2~ ~ ~ Auxiliary and Control Circuit TerminalScrew SizeofConnectableWire( mm2 ) SolderlessTerminal( mm2 ) Tightening Torque(kgf ㆍcm ) Line (Magnetic Contactor) (Overload Relay) Line (Magnetic Contactor) (Overload Relay) Line () (Overload Relay) Line (Magnetic Contactor) (Overload Relay) TMC9~48 M3.5 M ~2(ø1.6) 1.25~2(ø1.6) ~ ~ TMC50~85 TMC220 M4 M3.5 TMC100~180 M4 M4 1.25~5.5 (ø1.2~2.6) 1.25~5.5 (ø1.2~2.6) 1.25~2 (ø1.6) 1.25~5.5 (ø1.2~2.6) ~ ~ ~ ~ Fluorescent Lamps A fluorescent lamp is the combination of a lamp and a ballast, and depending on the type of the starting method of the ballast, it can be classified into a starter or a quick starter. The starter method turns on the lamp by use of a manual switch or an automatic switch such as a glow lamp, widely used for households. On the other hand, the rapid starter method turns on the lamp immediately after the switch is turned on without the use of a mechanical contact, generally applied for buildings, factories, hospitals and schools. The starting current of a fluorescent lamp varies depending on the ballast circuit and whether or not the power factor adjustment capacitor exists in the circuit. In any case, as the starting current is about 10 times of the normal operating current, so it is recommended to select the magnetic contactor so that its capacity is the same as lower than operating current. Number of rapid starter fluorescent lamps (high power factor type) that can be switched T Y P E Source Voltage Consumption 100V (Unit: Lamps) 200V (Unit: Lamps) 40W 60W 80W 110W 220W 40W 60W 80W 110W 220W No. of lamps Input (A) TMC9 TMC12 TMC (1.2) 18 (9) 22 (10) 30 (15) 0.96 (1.1) 11 (10) 13 (11) 18 (16) (0.6) 37 (18) 44 (21) 62 (30) 0.48 (0.55) 22 (20) 27 (23) 37 (32) TMC22 32 (15) 19 (17) (31) 39 (34) TMC32 44 (21) 27 (23) (43) 54 (47) TMC40 59 (29) 36 (31) (58) 72 (63) TMC50 84 (41) 52 (45) (83) 104 (90) TMC (54) 67 (59) (108) 135 (118) ) In 40W, 1 lamp, the figures in parentheses indicate the case of low power factor type. 2) In 40W, 2 lamps, the figures in parentheses indicate the case of flickerless type fluorescent lamps (Flickerless type fluorescent lamp: Fluorescent lamp that is embedded the circuit preventing flicker when the lamp is turned on) 90 Best Quality & Best Price The Highest Quality Products Information 91

12 MCCB ELCB Circuit Protector DC Contactor Relay Mercury Lamps External Dimension A mercury lamp is the combination of a mercury lamp and a ballast, and the starting characteristics of a mercury lamp vary depending on the type of the ballast. The types of ballasts are the general type (low P.F. type and high P.F. type), the fixed power type and the low starting current type and the respective starting characteristics are shown in the graph in the right. For the general type and the low starting current type, a starting current of 1.2 to 1.8 times of the rated current flows through the ballast for the first few minutes. Besides, the starting current of the fixed power type is lower than the ballast. The high P.F. type is inserted in a power factor adjustment capacitor in parallel with the power source, which causes an inrush current at the moment of starting. When a magnetic contactor is used, the point of consideration is the durability of the magnetic contactor against over current. However, our magnetic contactors are capable of withstanding the over current of 1.2 to 1.8 times of the rated current for some minutes without a problem. Therefore the selection of the magnetic contactor is recommended so that the input current of the ballast is within the input current. Example of starting characteristics Change in input (%) Time(min) External Dimension Mounting Dimension TMC9 TMC12 TMC18 TMC22 Number of general type mercury lamps that can be switched Source Voltage 100V(Low P.F type/high P.F type) (Unit: lamps) 200V (Low P.F. type/high P.F. type) (Unit : lamps) Consumption 40W 100W 200W 250W 300W 400W 700W 1000W 40W 100W 200W 250W 300W 400W 700W 1000W Input 1.25/ / / /30 6.0/ / /8.5 21/ /- 1.0/ / / / / / /5.8 TMC9 8/20 4/7 2/4 2/3 1/2 1/1 -/- -/- 20/- 11/16 5/9 5/7 4/6 3/4 1/2 1/1 TMC12 10/23 5/9 2/5 2/4 2/3 1/1 -/1 -/1 24/- 13/20 6/10 6/8 5/7 3/5 2/3 1/2 TMC22S TMC32S TMC40S T Y P E TMC18 14/32 6/12 3/6 3/6 3/4 2/3 1/2 -/1 33/- 18/27 9/15 8/12 7/10 5/7 3/3 2/3 TMC22 15/34 7/13 4/7 3/6 3/5 2/3 1/2 -/1 35/- 19/29 10/15 9/12 7/10 5/8 3/4 2/3 TMC32 20/47 10/18 5/10 5/8 4/7 3/5 1/3 1/2 49/- 26/40 13/21 12/17 10/14 7/11 4/6 3/4 TMC40 28/63 13/25 7/13 6/11 5/9 4/7 2/4 1/2 66/- 35/53 18/29 16/23 14/19 10/15 5/8 4/6 TMC50 40/90 19/35 10/19 9/16 8/13 6/10 3/5 2/4 94/- 50/76 26/41 23/33 20/27 15/21 8/12 6/8 TMC65 52/118 25/46 14/25 12/21 10/17 8/13 4/7 3/5 122/- 65/100 34/54 30/43 26/36 19/28 11/15 7/11 TMC32 TMC40 TMC48 for Transformers Below table is applied to the case that the inrush current of the transformer is less than 20 times of the rated current (effective value). Single Phase 3 Phase 220V 440V 220V 440V (kva) (A) (kva) (A) (kva) (A) (kva) (A) TMC TMC TMC TMC50 TMC65 TMC75 TMC TMC TMC TMC TMC TMC TMC TMC TMC TMC TMC100 TMC125 TMC TMC TMC Best Quality & Best Price The Highest Quality Products Information 93

13 MCCB ELCB Circuit Protector DC Contactor Relay External Dimension External Dimension Mounting Dimension for Special Environments High Temperature (Coil terminal) In case magnetic circuit breakers and magnetic contactor are used at a high ambient temperature, it primarily affects the insulation life span of the control coil (continuous switch-on life span) and the time-related change of the molded products. (Main Terminal) Low Temperature TMC150 TMC180 (Aux. Terminal) If magnetic circuit breakers and magnetic contactor are used in frigid weather condition, please refer to the storage and operating temperature. Tropical Zone What affects the export products that pass the tropical zone most seriously is high humidity, which causes fungi and rust. In such a case, please make sure to insert desiccant in the packing of the export products Mounting Hole Dust As the environments of foundries, construction sites or powder transfer equipment have relatively a large amount of dust, the panel containing magnetic circuit breakers and magnetic contactor should be of a dust-proof structure. TMC220 (Coil terminal) (Main Terminal) (Aux. Terminal) Corrosive Gas Corrosive gases that can exist in the environment where magnetic circuit breakers and magnetic contactor are in use are sulfurous acid gas (SO2), hydrogen sulphide (H2S), chloride (Cl2) and ammonia (NH3). The most of the conductors have been plated and are safe from these gases, but there is no way to improve the corrosion resistance of contacts. Existence of a corrosive gas may increase the electrical resistance of the contacts, resulting in high temperature rise. At this time, low humidity helps slow down the progress of corrosion. Therefore, maintaining the air in the panel dry can be a first remedy in such an environment. Warning 25 Mounting Hole Performance The performance set forth in this catalog has been described according to the conditions stipulated in KSC 4504 AC magnetic circuit breakers. Please pay attention to the fact that your actual operating conditions may differ from those stipulated in the above mentioned specifications. Contact Configuration(TMC) Operating Condition 1)Ambient Temperature Even under normal operating conditions, deterioration of insulation and consequential burnout may occur. Especially at high ambient temperature, insulation life span becomes shorter. In general, increase of ambient temperature by 6 to 10 cuts down insulation life span to a half. If the ambient temperature is high and at the same time a high voltage exceeding the rated voltage is continuously applied to the coil, the temperature of the coil rises and its life span could be extremely shortened. 2)Vibration and Impact Up to vibration of 2G and impact of 5G, no malfunction takes place at the contact. However, even within the limitation, if vibration or impact is applied to the device ceaselessly, malfunction may occur. In particular, care should be taken to the fact that resonance in the panel where the devices are mounted could be amplified by a large extent. TMC-9~22 TMC-22S~40S TMC-32~220 3)Contact If the contact melts down caused by excessively high current or abnormal wear of the contact, the connected machinery may be exposed to a serious danger. Please secure safety if mechanical stall or melted-down contact makes it impossible to switch on or off the device. Replace the magnetic circuit breaker or the magnetic contactor and consult our service center. Magnetic Switch Contact Configuration (TMS) TMS-9~22 TMS-22S~40S TMS-22~85 94 Best Quality & Best Price The Highest Quality Products Information 95

14 MCCB ELCB Circuit Protector DC Contactor Relay Control Relays DAR(D)4b DAR(D)6b DAR(D)8b Performance 형명극수개폐빈도 ( 회 / 시 ) 기계적수명 ( 만회 ) 전기적수명 ( 만회 ) AC15(11) 급 AC12(13) 급 DC13(11),12(14) 급 220V 440V 220V 440V 12~220V DAR(D)4b 4 1,800 1, DAR(D)6b 6 1,800 1, DAR(D)8b 8 1,800 1, Coil 1) AC Coil 2) DC Coil Features Rated Voltage (Designation) Rated Voltage (Designation) Increased contact reliability by using pure silver contact exclusively. Mechanical endurance is more than 10mil. times and for electrical, It guarantees more than 0.5 to 1mil. times according to the rated currents. ㆍ 35 mm DIN-Rail mounting is available for all types. DAR(D)4b DAR(D)6b DAR(D)8b Coil Characteristic 24V,48V,110V,120V 220V,240V,380V,440V,480V DAR(D)4b DAR(D)6b DAR(D)8b 12V, 24V, 48V 100V, 110V, 120V 200V, 220V, 250V 1) AC Coil (AC220V, 60 Hz ) AC DC DAR(D)4b DAR(D)6b DAR(D)8b Contact Configuration 4a,3a1b,2a2b,1a3b,4b 6a,5a1b,4a2b,3a3b,2a4b 8a,7a1b,6a2b,5a3b,4a4b Rated Insulation Voltage(Ui) Rated Thermal (AC1) Rated (A) Making, Breaking (A) Rated (A) Making, Breakind (A) Category AC15(11) (Coil ) AC12(13) (Resistive ) 690V AC110V 6 10 AC220V 3 8 AC440V AC550V AC110V AC220V AC440V AC550V Category DC13(11) (Coil ) DC12(14)(Resistive ) DC24V 3 5 DC48V DC110V DC220V DC24V DC48V DC110V DC220V A DAR4b DAR6b DAR8b 4a 1) DC Coil (DC110V) DAR4b DAR6b DAR8b Electromagnet Capacity(VA) dissipation (W) Inrush Holding Pick-up Drop-out Operating Voltage(V) Operating Time( ms ) Coil ON a contact ON Coil ON b contact OFF Coil ON a contact ON Coil ON b contact OFF 141~ ~125 10~17-7~13-2a2b 138~ ~130 8~15 6~15 7~13 8~15 6a 145~ ~120 10~17-7~13-3a3b 140~ ~125 10~16 5~13 7~13 8~15 8a 150~160 90~110 10~18-7~13-4a4b 148~158 95~115 10~16 5~13 7~13 8~15 4a Electromagnet Capacity(VA) Thermal Operating Voltage(V) Operating Time( ms ) Contact Coil ON Coil ON Inrush Holding ( ms ) Pick-up Drop-out a contact ON b contact OFF Coil ON a contact ON Coil ON b contact OFF 65~75 15~35 45~55-7~13-2a2b 63~73 18~38 40~50 20~30 7~13 13~19 6a 68~78 15~35 45~55-7~13-3a3b 63~73 18~38 40~50 20~30 7~13 13~19 8a 70~80 15~35 45~55-7~13-4a4b 63~73 18~38 40~50 20~30 7~13 13~19 96 Best Quality & Best Price The Highest Quality Products Information 97

15 MCCB ELCB Circuit Protector DC Contactor Relay External Dimension and Installation Model External Dimension Installation Dimension Contact Configuration Contact Contact Configuration Contact Contact Configuration Contact Contact Configuration M3.5 (Coil Terminal) a 3a1b 2a2b M3.5 (Main Terminal) 5 DAR(D)4b DAR(D)4b M4 Mounting Hole 3 1a3b 4b 6a 5a1b 4a2b M3.5 (Coil Terminal) M3.5 (Main Terminal) DAR(D)6b DAR(D)6b 3a3b 2a4b M4 Mounting Hole 8a 7a1b 6a2b M3.5 (Coil Terminal) M3.5 (Main Terminal) DAR(D)8b DAR(D)8b M4 Mounting Hole 5a3b 4a4b 98 Best Quality & Best Price The Highest Quality Products Information 99

16 MCCB ELCB Circuit Protector DC Contactor Relay Auxiliary Contact Unit External Dimension and Contact Configurations Head-On Model External Dimension Contact Configurations TU M3.5(Aux. Terminal) weight :28g and Head-On Poles Contact Configuration TU M3.5(Aux. Terminal) weight : 50g 35 TU2 2 2a, 1a1b, 2b TU4 4 4a, 3a1b, 2a2b, 1a3b, 4b TMC9~85 Side-On Side-On Poles Contact Configuration TU1 2 1a1b TMC9~85 Model External Dimension Contact Configurations M3.5(Aux. Terminal) 52.9 TU AC15 (11) (AC Coil ) DC13(11) (DC Coil ) Rated (A) AC12(13) (AC Resistive ) DC12(14) (DC Resistive ) Ith(A) AC1 weight:28g TU How to Assembly and Disassembly Head-On TU2 / TU4 TU1 TU Side-On TU Performance Operating Cycle (times/h) Mechanical Endurance (10,000) Electrical Endurance (10,000) AC15(11) AC12(13) DC13(11), DC12(14) 220V 440V 220V 440V 24V~220V TU2 1,800 2, TU4 1,800 2, TU1 1,800 2, For assembly, set the auxiliary contact unit to the projected part of the head and push it inside. For disassembly, lift the handle and reverse the sequence of assembly. For Assembly, with the crossbar of the magnetic contactor pressed down 3 to 4 mm using a minus screwdriver, set the projected part of the auxiliary contact unit to the groove of the crossbar on the side of the magnetic contactor and push it. For disassembly, remove the auxiliary contact unit using a minus driver. 100 Best Quality & Best Price The Highest Quality Products Information 101

17 MCCB ELCB Circuit Protector DC Contactor Relay Sequence of Selection of Magnetic Switches Thermal Overload Relays Capacity of Main Contact of the of ㆍ Standards of 3-phase squirrel cage motors and single phase motors applied Thermal Overload Relay protects the motor from overload, stall, phase loss operation and burn out. Resistive ㆍ Standards of Resistive s applied ㆍ Single phase Resistive s DC ㆍ DC loads in serial connection methods of contacts Capacitor ㆍ Single and 3 phase capacitor circuits applied Transformer ㆍ Single and 3 phase Transformers Operation Method Lighting Direct On-Line Starting ㆍIncandescent, Fluorescent and Mercury lamps applied ㆍStandards of 3 phase squirrel cage motors and single phase motors applied Operating Voltage of the Operating Environments and Mounting Conditions Endurance Source Voltage Auxiliary Circuits Availability of Case and Cover Response to Special Environments Domestic Standards International Standards Selection on the ratings of the on the Starting Purpose of Protection Star-Delta Starting Inching and Plugging application Reversible operation Electrical On/Off endurance Mechanical On/Off endurance Coil Voltage Response to Voltage Fluctuation Aux. Contact Configuration Case and Cover Tropical or Frigid Zone Special Environments KS, Safety Certification IEC(CE), VDE, UL, CSA etc. s Full Capacity s with Short Starting Time (submersible pumps, compressors, etc.) s with Long Starting Time Protection from Overload and Stall Protection from Phase Loss ㆍ Star-Delta starting applied ㆍ Automatic Star-Delta starting devices ㆍ Inching(10%, 50%, 100%), Plugging applied ㆍ Reversing Magnetic Switches/Contactors ㆍ On/Off Endurance Curve ㆍ Direct On-Line Starting applied with electrical endurance considered ㆍ Performance ㆍ Coil List ㆍ Voltage Fluctuation(area, location) considered ㆍ Refer to the Product List ㆍ Enclosed type magnetic contactor ㆍ Push button type magnetic contactor ㆍ Dust proof and water proof magnetic contactor ㆍ Tropical and humid area or cold and frigid area ㆍ Protection from dust and corrosive gas ㆍ The full load of the motor applied ㆍStandards on the overload relays applied depending on the motor capacity ㆍMagnetic switches with quick acting overload relays ㆍ Slow acting magnetic switches ㆍ Standard magnetic switches ㆍ On/Off Endurance (Life span curve) ㆍ Direct On-Line Starting applied with electrical endurance considered Direct connection to a magnetic contactor Easy Operation A ㆍ Setting The rated current can be set with a Philips or flat head screw driver as follow of. ㆍ Easy in setting Manual-Auto Reset For the increased convenience of the user, you can select manual reset or automatic reset at your choice. Our thermal overload relays are conveniently connected to a magnetic contactor without any wire. (Applicable : DTH22b, 40, 85) 90 1 A H ㆍAutomatic Reset Push down the reset screw and turn it so that the arrow mark points to A. ㆍExternal Manual Trip For the increased convenience of the user, external manual trip is possible. It lifts up when the relay is trip for clear distinction. A H A H A ㆍManual Reset As shown on the right, turn the reset screw so that the arrow mark points to H and allow the screw to lift up. Separate Mounting Unit In case of mounting the overload relays independently, the separate mounting kits are available for panel installation with rail or screw (Applied types: DTH22b, 40, 85) H Export (Overseas Standards) - Response to UL, CE Certification 102 Best Quality & Best Price The Highest Quality Products Information 103

18 MCCB ELCB Circuit Protector DC Contactor Relay Characteristics and s Independent 1a1b Contact Subject Nominal DTH22b DTH40 DTH85 range range range Min. Mid. Max. Min. Mid. Max. Min. Mid. Max The a (NO) contact and the b (NC) contact are totally separated and allow you to use different voltage for each contact. Combination with a TMC9,12,18,22 TMC32,40,48 TMC50,65,75,85 Thermal Overload Relay DTH-22b DTH-40 DTH-85 Rated (A) s of Auxiliary Contact Rated Operating (A) Product AC 15(11) (AC Coil ) DC 13(11) (DC Coil ) 110V 220V 550V 110V 220V DTH-22b,40, Order Code DTH 22-5A Model Thermal Over Relay Ampare Frame ~22A 40 4~40A 85 7~85A No. of Elements - 2 Elements 3 3 Elements Rated (at AC 440) ~ ~ ~ ~ ~ ~ ~ ~36 No. of Elements 2 Elements Standard Standard Standard 3 Elements Option Option Option Aux. Contact 1a1b 1a1b 1a1b Reset Method Manual / Auto Manual / Auto Manual / Auto Loss of Heater 1.8VA/Pole 2.0VA/Pole 3.5VA/Pole ~ ~ ~ ~ ~ ~ ~ ~65 5 4~ ~ ~ ~ ~ ~ ~ ~85 Dimension( mm )(W H D) Separate Mounting Unit DZ22b DZ40-3 Elements DTH22b/3 DTH40/3 DTH85/3 Phase Loss Protection DTK22b DTK40 DTK85 Direct DTZ22b DTZ40 - TMC9,12,18,22 TMC32,40,48 TMC50,65,75, ~13 Magnetic Switch TMS9,12,18,22 TMS32,40,48 TMS50,65,75, Best Quality & Best Price The Highest Quality Products Information 105

A7 Magnetic Contact/Switch CONTENTS

A7 Magnetic Contact/Switch CONTENTS A7 Magnetic Contact/Switch CONTENTS A7-02 Magnetic Contact / Switch VMC9~85 Medium/Small Capacity VITZRO Magnetic Contact/Switch provides customers with the safety as the first priority which is the core

More information

Electric Equipment General Catalog

Electric Equipment General Catalog Electric Equipment General Catalog Magnetic Contactors Thermal Overload Relay Magnetic Contactor Thermal Overload Relay Low Voltage Equipments Contactor Contents Main Features Development Figure of Components

More information

FUJI Magnetic Contactors and Motor Starters

FUJI Magnetic Contactors and Motor Starters FUJI Magnetic Contactors and Motor Starters Technical Information AEH28a CONTENTS Chapter Contactors and Starters - International standards... 4-2 Ratings and specifications... 8-3 Performance and characteristics...

More information

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires

More information

Ktec Contactors and thermal overloads

Ktec Contactors and thermal overloads Contactors and thermal overloads Techna KTEC series contactors provide a complete solution for your ac contactor requirements.the range carries TUV, UL & CSA certification, for use in Europe, North America

More information

Technical Information

Technical Information C5 C5- C5- C5- C5- C5-550 ➊ 700 860 1000 1200 Rated Insulation Voltage U i to IEC 947-1 [V] 1000V 1000V 1000V 690V 690V UL/CS [V] 600V Rated Impulse Voltage U imp C5-550 / 700 / 860 [kv] 3.5 C5-1000 /

More information

CI-TI Contactors and motor starters Types CI 61 - CI 98

CI-TI Contactors and motor starters Types CI 61 - CI 98 Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include

More information

Industrial Contactors CTX 3 3P 185A - 800A

Industrial Contactors CTX 3 3P 185A - 800A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...

More information

MAGNETIC CONTACTOR & MOTOR STARTER

MAGNETIC CONTACTOR & MOTOR STARTER http://www.seec.com.tw http://circuit-breaker.seec.com.tw MAGNETIC CONTACTOR & MOTOR STARTER P Functionalities and characteristics of Magnetic Contactor Configuration Composite magnetic switch (abbreviated

More information

MAGNETIC CONTACTOR & MOTOR STARTER

MAGNETIC CONTACTOR & MOTOR STARTER http://www.seec.com.tw http://circuit-breaker.seec.com.tw MAGNETIC CONTACTOR & MOTOR STARTER P Functionalities and characteristics of Magnetic Contactor Configuration Composite magnetic switch (abbreviated

More information

Quick selection table

Quick selection table Quick selection table Contactors... 100 to 800A Frame size 100A 15A 150A -pole Contactors s AC/DC common coil See page 46 for more details CGC-100 CGC-15 CGC-150 See page 46 for more details Ratings /

More information

HEAVY DUTY POWER RELAYS FEATURES

HEAVY DUTY POWER RELAYS FEATURES VDE VC HEAVY DUTY POWER RELAYS VC RELAYS Faston terminal Screw terminal mm 9 FEATURES VC power relays are designed for controlling heavy duty loads safely: Contact gap of 3 mm or more -point contacts for

More information

Series CA5 Contactors

Series CA5 Contactors Series C5 Contactors The contactor for heavy industrial applications from 500HP to 900HP DISCONTINUED This series is being replaced by the C9 Series of contactors C5 Series contactors provide large horsepower

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

Innovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual

Innovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual Innovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual 11-M61E TABLE OF CONTENTS HANDLING & MAINTENANCE Storage 1 Transport 1 STANDARD ENVIRONMENT 1 INSTALLATION AND CONNECTION

More information

A Contactors. Technical Information. CA4 Miniature Contactors. Technical Information A94 CA4. Switching Motor Loads.

A Contactors. Technical Information. CA4 Miniature Contactors. Technical Information A94 CA4. Switching Motor Loads. C4 Miniature Contactors Contactors C4 Rated Insulation Voltage U i to IEC 947-1 [V] 500V UL/CS [V] 600V Rated Impulse Voltage U imp [kv] 8 Rated Voltage U e Main Contacts C 50/60Hz [V] 230, 240, 400, 415,

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

Contactor Types CI 61-98

Contactor Types CI 61-98 MKING MODERN LIVING POSSIBLE Data sheet Contactor s CI 6-98 Contactors CI 6, CI 73, CI 86 and CI 98 switch powers of up to 30 kw, 37 kw, 45 kw and 55 kw respectively under 3 380 V C-3 loads. ccessories

More information

Industrial contactors CTX-1

Industrial contactors CTX-1 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 Industrial contactors /04/05/10/12/14/15/20/22/24/25/30/32/34/35/40/42/44/45 CONTENTS PAGE 1. Use... 1 2. Range... 1 3. Electrical

More information

YS Series Contactors YS1N- F11 ****

YS Series Contactors YS1N- F11 **** YS Series YS Series Contactors Key features of the YS Series include: Compact size AC and C coil, reversing and non-reversing Weld-resistant silver alloy contacts No cadium used in contacts Highly reliable

More information

MAGNETIC CONTACTORS & OVERLOAD RELAYS DAERYUK CO., LTD.

MAGNETIC CONTACTORS & OVERLOAD RELAYS DAERYUK CO., LTD. MAGNETIC CONTACTORS & OVERLOAD RELAYS DAERYUK CO., LTD. MAGNETIC CONTACTORS & OVERLOAD RELAYS R&D capability is proportional to corporate competitiveness as well as selfconfidence. We are moving forward

More information

DAERYUK CO., LTD.

DAERYUK CO., LTD. www.edaco.net DAERYUK CO., LTD. Head Office & Factory 530, Samkyeri, Pogokeup, Cheoingu, Yonginsi, Kyunggido, Korea TEL : +82313343371~3 FAX : +82313343374 Specifications in this catalog are subject to

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

and Refrigeration Institute). CNX Special Purpose Contactors

and Refrigeration Institute). CNX Special Purpose Contactors Series C7 Special Use Contactors Contactors designed and labeled for specific industrial applications Special Use Contactors Hydraulic elevator duty contactors HVC rated contactors Lighting contactors

More information

Direct On Line (DOL) Motor Starter. Direct Online Motor Starter

Direct On Line (DOL) Motor Starter. Direct Online Motor Starter Direct On Line (DOL) Motor Starter Direct Online Motor Starter Different starting methods are employed for starting induction motors because Induction Motor draws more starting current during starting.

More information

Essential equipment for all your requirements

Essential equipment for all your requirements NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides

More information

Installation Contactors RIC, RAC

Installation Contactors RIC, RAC Installation Contactors RIC, RAC 1 Characteristics Rated operational current: 20 63 A Coil voltages: UC 24, 36, 230 V / AC 400 V Hum-free (UC versions) 2 4 contacts NC or NO Extendable with auxiliary contacts

More information

Modular contactors and relays

Modular contactors and relays pages /4 to / pages /8 and /9 pages /10 and /11 pages /12 and /13 Presentation and standards Presentation Designed for use in modular panels and enclosures, these contactors feature : i Easy installation

More information

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5- MKING MODERN LIVING POSSIBLE Technical brochure Minicontactors CI 5- www.danfoss.com 2 IC.PD.C10.F3.02-520B4167 Danfoss /S, C-SMC, mr, 07-2010 Contents Page Minicontactor CI 5- Introduction...............................................................................4

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

Other Devices. Installation Contactors Z-SCH. Connection diagrams Z-SCH NO 3 NO / 1 NC. Permitted Installation Positions

Other Devices. Installation Contactors Z-SCH. Connection diagrams Z-SCH NO 3 NO / 1 NC. Permitted Installation Positions Installation Contactors Z-SCH These switching devices have been designed and rated particularly for modular installation in modular distribution boxes for electrical installation or cabinets with device

More information

ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters. Lecture 6 Contactors and Motor Starters

ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters. Lecture 6 Contactors and Motor Starters ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters Text Book: Chapter 6, Electric Motors and Control Systems, by Frank D. Petruzella, published by McGraw Hill, 2015. Paul I-Hai

More information

Modular contactor for installation into distribution boards

Modular contactor for installation into distribution boards Modular contactor for installation into distribution boards Description Modular contactors are used for installation in consumer units in dwellings, business premises, hotels, hospitals, shopping centres,

More information

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload According to CE, IEC 947, EN 60947 Contactor Catalogue 3 Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload Mini-Contactors 4kW - 5.5kW DC Contactors Mini-Relays 10A Motor Starter DOL, Star-Delta Capacitor

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

Controls. CONTACTORS CWB Line (up to 40A)

Controls. CONTACTORS CWB Line (up to 40A) Controls CONTACTORS CWB Line (up to 40A) 0800 367 934 Contactors CWB Line (up to 40A) CONTACTORS CWB Line (up to 40A) Summary New WEG CWB Contactors 4 The Technology Within 6 Energy Savings 7 Easy Panel

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

Technical Information

Technical Information Miniature Technical Information -09-12 Rated Insulation Voltage U i to IEC947-1 [V] 690V UL/CS [V] 600V Rated Impulse Voltage Withstand U imp [kv] 6 Rated Voltage Ue-Main Contacts C 50/60Hz [V] 230, 240,

More information

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30 Characteristics TeSys contactors Mini-contactors TeSys LC SK and LP SK Environment Rated insulation voltage (Ui) Conforming to 0, VDE 00 gr C,BS, CSA - n, UL 0 V 0 Conforming to standards IEC 0, NF C -0,

More information

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1 Motor Contactor J7KN Range from 4 to 500 kw (AC 3, 380/415 V) AC and DC operated Integrated auxiliary contacts; integrated aux. contact of J7KN contactors up to 11kW suitable for electronic circuits Screw

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD. DATASHEET - DILMC9-10(24VDC) Technical data General Contactor, 3p+1N/O, 4kW/400V/AC3 Part no. DILMC9-10(24VDC) Catalog No. 277468 Eaton Catalog No. XTCEC009B10TD EL-Nummer 4110305 (Norway) Standards IEC/EN

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays New generation of Contactors from LS Industrial Systems Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol

More information

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5 3-pole DC Operated Ratings Rated Aux. Contacts Type Coil voltage 1) AC2 Current Built-in Additional 24 24V= DC 5 AC3 see 48 60V= DC 6 380V AC1 page 34 110 110V= DC 7 400V 660V 220 220V= DC 8 415V 690V

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

CI-TI Contactors and Motor Starters Type CI 6-50

CI-TI Contactors and Motor Starters Type CI 6-50 Data sheet CI-TI Contactors and Motor Starters CI 6-50 CI-TI contactors and motor starters provide trouble-free switching and maximum protection for costly motors and other electrical equipment. The components

More information

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 CTX 3 Control relays Cat. N (s) : 4 168 00..04/06/09..14/16/19..24/26/29 CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3.

More information

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data B6, B7, BC6, BC7, TBC7 - and 4-pole mini contactors VB6, VB7, VBC6, VBC7 - and 4-pole mini reversing contactors Main pole Utilization characteristics according to IEC Standards IEC/EN 60947-1, IEC/EN 60947-4-1

More information

Starting of Induction Motors

Starting of Induction Motors 1- Star Delta Starter The method achieved low starting current by first connecting the stator winding in star configuration, and then after the motor reaches a certain speed, throw switch changes the winding

More information

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660 Characteristics Environment Rated insulation voltage (Ui) Conforming to IEC/EN 60947-1, V 690 IEC/EN 60947-4-1, VDE 0110 gr C, CSA - n 14, UL 508.1 Conforming to standards IEC/EN 60947-1, IEC/EN 60947-4-1,

More information

THREE-POLE CONTACTORS series HR09-HR13 up to 6 kw

THREE-POLE CONTACTORS series HR09-HR13 up to 6 kw THREE-POLE CONTACTORS series HR09-HR3 up 6 kw USE Series HR contacrs are particularly suitable for controlling mors, heating elements and three-phase and single-phase loads in general. OPERATION AND INSTALLATION

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

Mini Contactors CI 4-

Mini Contactors CI 4- Data sheet Mini Contactors CI 4- Introduction CI 4 minicontactors cover the power range 1.5 to 5.9 kw and are available for a.c. and d.c. coil voltages. Characteristic of the minicontactors is that they

More information

Technical Information

Technical Information -100 Controller IEC Performance Data (CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device Catalog No. -100... 25A 40A 63A 90A Maximum Short-Circuit Current 480V [ka] 65 65 42

More information

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866) .4 Miniature Circuit Breakers and Supplementary Protectors SPHM Supplementary Protector SPHM Supplementary Protector Product Description The SPHM Supplementary Protector is a dual rated product for both

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France Contact us ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F-69687 Chassieu cedex / France You can find the address of your local sales organisation on

More information

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line Motors Automation Energy Transmission & Distribution Coatings Automation Contactors - CWM Line 2 Contactores Compactos CWC0 Contactors - CWM Line Sumary Presentation Accessories Overview 5 Three-Pole Contactors

More information

The contactor for large horsepower applications

The contactor for large horsepower applications Series The complete contactor for heavy industrial applications from 500HP to 900HP R Series contactors provide large horsepower performance with a design that is up to 40% smaller than traditional contactors

More information

Technical Information

Technical Information Contactors Contactors 95(-EI) 110(-EI) 140(-EI) 180(-EI) 210-EI 250-EI 300-EI 420-EI 630-EI 860-EI Rated Insulation Voltage U i IEC, S, BS, SEV, VDE 0660 [V] 1000V UL; CS [V] 600V Rated Impulse Voltage

More information

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1 Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427 Data sheet CI-TI TM Contactors and Motor Starters Circuit Breakers November 2002 DKACT.PD.C00.L2.02 520B1427 Introduction Circuit breakers/manual motor starters cover the power ranges 0.09-12.5 kw This

More information

CI-TI TM Contactors and Motor Starters Contactors CI 6-50

CI-TI TM Contactors and Motor Starters Contactors CI 6-50 Data sheet CI-TI TM Contactors and Motor Starters Contactors CI 6-50 Description Danfoss contactors CI 6-50 cover the power range 2.2-25 kw. CI 6 is built up as a combined contactor/control relay. CI 9

More information

22AF 40AF AF 150AF 225AF 400AF 800AF

22AF 40AF AF 150AF 225AF 400AF 800AF Contactors MC-Series UL508 E108780 Contactor 3 Pole Standards and Certifications UL508 IEC 60947-2 & IEC 60947-4-2 CSA C22.2 No.14 Features 8 Frame Sizes 1/2HP up to 600HP @ 480V AC Screw Terminals (Lug

More information

For Info: Phone: Fax:

For Info:   Phone: Fax: Page -2 TWO POLES IEC rated current Ith: 20A (AC1) IEC operational power: 1.3kW (AC3 230V) Ideal for domestic applications. Page -2 THREE AND FOUR POLES IEC rated current Ith: 25A, 40A and 63A (AC1) IEC

More information

OSS - TN, TBN Type. Information to Order. Features. External View ATS(60~600A) OSS P- A B C D. Rated Current. D Operating Voltage

OSS - TN, TBN Type. Information to Order. Features. External View ATS(60~600A) OSS P- A B C D. Rated Current. D Operating Voltage Information to Order A Rated Current 06 1 60A 100A 2 4 400A 6 600A B Type TN : TN-Type TBN : TBN-Type C Number of Poles 2 : 2P 3 : 3P 4 : 4P OSS - 6 - - P- A B C D D Operating Voltage A1 : AC 110V A2 :

More information

MS Overview. General purpose contactors. MS Overview. General purpose contactors. The main benefits: Handling of the contactors

MS Overview. General purpose contactors. MS Overview. General purpose contactors. The main benefits: Handling of the contactors MS Overview General purpose contactors General purpose contactors The main benefits: Coil terminals Mounting pitch DIN rail mounting catch Model name Indication of surge absorber (optional) Rated voltage

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

The breakers offer thermal-magnetic trip protection according to Z and K characteristics. Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific

More information

Memshield - ACB Ratings & Specifications

Memshield - ACB Ratings & Specifications Memshield Memshield - ACB Ratings & Specifications Rating and specifications Current rating, A List No Number of poles RATED CURRENT (A) [In] IEC, BS, VDE, AS Neutral pole ampere frame (A) RATED PRIMARY

More information

Application Mini Contactors for Motors and Resistive Loads

Application Mini Contactors for Motors and Resistive Loads Delivery program Contactor, 4p, 4kW/400V/AC3 Part no. DILEM4-G(24VDC) Catalog No. 012701 Eaton Catalog No. XTMF9A00TD Product range Contactors Application Mini Contactors for Motors and Resistive Loads

More information

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B Overcurrent Protective Device)

INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B Overcurrent Protective Device) INSTRUCTION MANUAL FOR AIR CIRCUIT BREAKERS (With Draw-out Cradle and Type AGR-11B Overcurrent Protective Device) Types: KA208S KA212S KA216S KA220S KA325S KA332S KA440S KA212H KA216H KA220H KA316H KA320H

More information

Bulletin 825 SMM Smart Motor Manager

Bulletin 825 SMM Smart Motor Manager Bulletin 825 SMM Smart Motor Manager Your order must include: Cat. no. of the Smart Motor Manager selected with supply Voltage Suffix Code, Cat. no. of Converter Module selected, and, If required, Cat.

More information

10 AMP POWER RELAY. Breakdown voltage* 2. Operate time* 3 (at nominal voltage) Shock resistance. Vibration resistance. Unit weight

10 AMP POWER RELAY. Breakdown voltage* 2. Operate time* 3 (at nominal voltage) Shock resistance. Vibration resistance. Unit weight VDE 2c, 3c AMP POWER RELAY RELAYS 2. 1.72 FEATURES Interchangeable with existing models Long life and high reliability High contact capacity up to A 20 Available with plug-in/solder and quick-connect terminals

More information

Bulletin 100-D IEC Contactors

Bulletin 100-D IEC Contactors Bulletin 100-D IEC Contactors Electronic and conventional coils AC & DC Integrated PLC interface Low power pick-up & hold-in Wide voltage ranges Complete range of accessories Environmentally friendly Compact

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed

More information

IEC Utilization Categories (Explanation)

IEC Utilization Categories (Explanation) IEC Utilization Categories (Explanation) IEC Utilization Categories Voltage Category Typical Applications A.C. A.C. and D.C. D.C. AC AC AC AC ACa ACb AC6a AC6b AC7a AC7b AC8a AC8b AC AC AC AC AC AC AC

More information

SWITCHGEAR. 4G cam switches

SWITCHGEAR. 4G cam switches SWITCHGEAR 178 4G cam switches ENERGY SAFELY SWITCHED 179 SWITCHGEAR 180 GENERAL INFORMATION 4G-series cam switches are low voltage switches, designed according to the latest knowledge about switchgear

More information

MITSUBISHI ELECTRIC. Low Voltage Switchgears Magnetic Contactors Thermal Overload Relays Contactor Relays MS-N. Technical Catalogue

MITSUBISHI ELECTRIC. Low Voltage Switchgears Magnetic Contactors Thermal Overload Relays Contactor Relays MS-N. Technical Catalogue Low Voltage Switchgears Magnetic Contactors Thermal Overload Relays Contactor Relays Technical Catalogue 2003/2004 Contactors Contactors The Magnetic Contactors series from : Designed with ease of use

More information

AE 9... AE 40 Contactors NE... Contactor Relays

AE 9... AE 40 Contactors NE... Contactor Relays Technical data AE 9... AE 0 Contactors NE... Contactor Relays AE 9... AE 0 Contactors NE.. Contactor Relays Contents AE 9... AE 0 Contactors Description... 2 Ordering Details... 3 Technical Data... Terminal

More information

C -5 to +55 (0.8 to 1.1Uc) Permissible o

C -5 to +55 (0.8 to 1.1Uc) Permissible o T - Line Contactors 3 & 4 Pole Contactors with C operating coils General Characteristics Type Unit TC1-D09 ~ TC1-D95 Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 VDEO 110grC/IEC 60947-4

More information

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors 90 Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 5424 Product certifications LCp

More information

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400 Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,

More information

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD Bulletin Product Selection Open Type and Non-Combination Enclosed (IP, NEMA /) Controllers For use with Line-Connected Motors Rated Voltage [V AC] / Motor Current [A]...... Max. kw, Hz Max. Hp, Hz Control

More information

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit SSR with Failure Detection Function Detects failures in SSRs used for heater temperature control and simultaneously outputs alarm signals. This product supports the safe design of heater control systems,

More information

ADS7 AC Contactor Starters

ADS7 AC Contactor Starters ADS7 AC Contactor Starters ADS7 starters fully comply with BS EN 60947-4-1, IEC 60947-4-1 and VDE 0660. The range offers a multitude of configurations and optional features including a complete choice

More information

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB6, VB7 -pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB7-0-10 2CDC211006F0011 Description VB6, VB7 -pole compact design reversing contactors are space optimized control

More information

JOSLYN CLARK VACUUM CONTACTOR FEATURES

JOSLYN CLARK VACUUM CONTACTOR FEATURES USAVAC COPACT INTERNATIONAL AC VACUU CONTACTOR International Ratings For World Wide Applications UL Listed CSA certified 600V/660V/1000V/1500V Joslyn Clark s unique Compact AC Vacuum Contactors & Starters

More information

4 - Miniature controls

4 - Miniature controls Index -....1.22 Selection Contactors for connection to PLCs, B6S & B7S, 3 phase...6 Contactors, Interface, B6 & B7, 3 phase...5 Contactors, features...1 Contactors, mechanically interlocked, B6 & B7, 3

More information

A200 NEMA Contactors and Starters A200

A200 NEMA Contactors and Starters A200 Starters Non-reversing and Reversing 11 Not to be used for construction purposes unless approved. Table 11. Open Reversing Starters Dimensions NEM of Poles Fig. Mounting Dimensions in Inches (mm) Screws

More information

Application Description

Application Description -14 Type, Intelligent Technologies (IT.) Soft Starters February 2007 Contents Description Page Type, Intelligent Technologies (IT.) Soft Starters Product Description....... -14 Application Description....

More information

INTERPLANT STANDARD - STEEL INDUSTRY

INTERPLANT STANDARD - STEEL INDUSTRY INTERPLANT STANDARD - STEEL INDUSTRY IPSS SPECIFICATION FOR MAGNETIC OVER- CURRENT RELAYS FOR ac AND dc MOTORS PROTECTION UP TO 650 V (FIRST REVISION) CORRESPONDING INDIAN STANDARD DOES NOT EXIST IPSS:1-04-008-11

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

NRBM Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

NRBM Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute NRBM circuit breakers are the largest in rated current (A to 50A) among the IDEC circuit breakers series. These small sized, high-effi ciency breakers offer a variety of protection characteristics that