2 Pag. 1 of 4 TEST REPORT No. Test performed in accordance with the standard ASTM B 117 (2003) issued by TÜV Rheinland Italia S.r.l. - Via Gavardina Trav. II, 42 I Ponte S. Marco (BS) 1. General information 1.0. Equipment under test (EUT): Connecting rods treatment with fluoropolymer ceramic coating Xylan Trade mark: TBV 1.2. Model (s) TIBI coat 4000-A 1.3 Manufacturer identification: I Sellero (BS) 1.4. Date of samples receipt : Date of test: The test results and observations indicated in this test report refer exclusively to the samples tested. It is not permitted to transfer the results to other systems or configurations. The publication or duplication of this test report with enclosures, or Part of this test report or enclosures, without a written consent of the test laboratory is not permitted. The test laboratory not assumes any liability to any party for any loss, expense or damage occasioned by the use of this report. Any use of the laboratories name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by the test laboratory. This report by itself does not imply that the material, product, or service is or has ever been under a TÜV certification program.

3 Pag. 2 of 4 2. Test descriptions Description of test Standard reference Exposure time Test results Salt spray test with NSS (Sodium Chloride Solution) solution 5% ASTM B 117 (2003) 5000 hrs PASSED 2.1 Remarks The sample s status after 5'000 hrs. of salt spray fog exposure is describes as follow: a deposit of corrosion of the type oxide of zinc is observed, therefore the protection of the treatment of the connecting rods and the dice results is within the Client specification for that it concerns the type TIBI coat 4000-A. The Responsible of Department Mr. Francesco Barbierato Ponte S. Marco,

4 Pag. 3 of 4 Annex 1 Test protocol Operative condition: Test specification : not applicable see photographic section in Annex 2 for the samples orientation The salt spray test with a sodium cloride solution (NSS mode) is performed as follow : Compressed Air pressure 0,98 bar; air humidifier temperature 49 C to give a temperature after decompression of 35 C when carrying out; quantity and distribution of the spray 1,5 ml/h. Duration of the test = hrs Instruments used: Manufacturer ID Lab. Reg. No.: Salt spray cabinet mod Elcometer ID210_SSOG_Milano Measurement uncertainty: Time: ± 0,1 s Temperature: ± 1 C Humidity: ± 1% Final test results Analysis After an exposure time of 5000 hrs, previous cleaning with running water, removal of the straining through action mechanical behavior with special brush in nylon and drying: blistering (ASTM D ) Minor at size 6 few red rusting (ASTM D ) < 5 % white rusting (ASTM D ) absent cracking (ASTM D (2005)) absent flaking (ASTM D (2005)) absent chalking (ASTM D 4214 met. a -1998) absent

5 Pag. 4 of 4 Annex 2 Photo No. 1: Samples identification after 5000 hrs exposure orientation of the samples in the NSS chamber

N , Vers. 0

N , Vers. 0 Page 1 of 11 TEST REPORT N. 55 0240 07, Vers. 0 Tests carried out in accordance to ASTM D 4280 04 issued by TÜV Rheinland Italia S.r.l. - Via Gavardina, 42 I-25010 Ponte S. Marco (BS) 1. General information

More information

ECE TYPE-APPROVAL CERTIFICATE

ECE TYPE-APPROVAL CERTIFICATE ECE TYPE-APPROVAL CERTIFICATE Communication concerning the approval extended of an electrical/electronic sub-assembly with regard to Regulation No.10. Approval No: E24 10R-040621 Extension No: 01 Reason

More information

Test Report Gonio-Photometry R V1

Test Report Gonio-Photometry R V1 R-957-1 V1 Test Report Gonio-Photometry R-957-1 V1 CUSTOMER INFORMATION KAUFEL Customer Route de Saint Martin D Ordon 89330 PIFFONDS Order followed by Mr Grégory MARBOEUF Customer Reference Order N SF

More information

SmartSensor 105 & Advance NEMA Salt Fog

SmartSensor 105 & Advance NEMA Salt Fog SmartSensor 105 & Advance NEMA Salt Fog Test Report Wavetronix products mentioned: SmartSensor 105 SmartSensor Advance As contracted by Wavetronix, Environ Laboratories LLC performed a NEMA salt fog test

More information

Test Report For: EMECO INDUSTRIES INC Bar Stool

Test Report For: EMECO INDUSTRIES INC Bar Stool 4700 Broadmoor SE, Suite 200 Kentwood, MI 49512 Telephone: 616-- 656-- 7401 Facsimile: 616-- 656-- 2022 www.intertek-- etlsemko.com EMECO INDUSTRIES INC P.O. No. N / A Page 1 of 18 Test Report For: EMECO

More information

oééçêí=çå=cáåçáåöë= OMNUMOMP=Ó=N^== - english version - Truncated version dated 12 th July 2018

oééçêí=çå=cáåçáåöë= OMNUMOMP=Ó=N^== - english version - Truncated version dated 12 th July 2018 oééçêí=çå=cáåçáåöë= = OMNUMOMP=Ó=N^== - english version - Truncated version dated 12 th July 2018 Commissioning Party: Renusol Europe GmbH Mr Nils Rossbach Piccoloministr. 2 51063 Cologne Testing location:

More information

EESTOR INC. TEST REPORT

EESTOR INC. TEST REPORT EESTOR INC. SCOPE OF WORK Performance testing of capacitive samples (Ceramic samples called 105-7, 207-2, 344-2B) REPORT NUMBER 103362995DAL-002 ISSUE DATE 29-JAN-2018 REVISION DATE 26-FEB-2018 PAGES 7

More information

TEST REPORT ENVIRONMENTAL EN 60529:1991+A1:2000

TEST REPORT ENVIRONMENTAL EN 60529:1991+A1:2000 Page 1 of 15 Report No 130313TRFENV Report Reference No.... : TEST REPORT ENVIRONMENTAL EN 60529:1991+A1:2000 130313TRFENV Tested by... : Alessio Pelizzoni. Verified by... : Fabio Mauri. Date of issue...

More information

TEST REPORT INTERTEK TESTING SERVICES NA, INC Arlingate Lane Columbus, OH, 43228

TEST REPORT INTERTEK TESTING SERVICES NA, INC Arlingate Lane Columbus, OH, 43228 TEST REPORT INTERTEK TESTING SERVICES NA, INC. 1717 Arlingate Lane Columbus, OH, 43228 PROJECT NO.: G101483861 ISSUE DATE: February 21, 2014 INTERIM REPORT NO. 101483861COL-001B RENDERED TO Client: TSI

More information

Report Number: G CRT-001A Model Number: Ionflow 50 Surface ARB Number: 1334

Report Number: G CRT-001A Model Number: Ionflow 50 Surface ARB Number: 1334 3933 US Route 11 Cortland, NY 13045 Telephone: +01 607 753 6711 Facsimile: +01 607 756 9891 www.intertek-etlsemko.com Order No. G100222377 28 January 2011 Revised 11 November 2011 Report Number: G100222377CRT-001A

More information

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: Sept 27, 2013 REVISED DATE: NA

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: Sept 27, 2013 REVISED DATE: NA REPORT NUMBER: 101351744MID-001 ORIGINAL ISSUE DATE: Sept 27, 2013 REVISED DATE: NA TEST REPORT EVALUATION CENTER Intertek Verification Center 8431 Murphy Dr Middleton, WI 53562 x RENDERED TO Marc Doheny

More information

Inspection Report. Coating name: IGP HWFclassic IGP Pulvertechnik AG Industrie Stelz, Ringstraße Wil Schweiz. Job number:

Inspection Report. Coating name: IGP HWFclassic IGP Pulvertechnik AG Industrie Stelz, Ringstraße Wil Schweiz. Job number: Inspection Report Referred to: AAMA 2604-13, Voluntary Specification, Performance Requirements and Test Procedures for High Performance Organic Coatings on Aluminium Extrusions and Panels Coating name:

More information

Salt Spray Test Chamber Model SSe CASS/AASS ASTM B 368 ISO 9227 JIZ 2371

Salt Spray Test Chamber Model SSe CASS/AASS ASTM B 368 ISO 9227 JIZ 2371 Salt Spray Test Chamber Model SSe CASS/AASS ASTM B 368 ISO 9227 JIZ 2371 Specification/Model SS600e CASS/AASS SS1000e CASS/AASS SS1300e CASS/AASS SS3000e CASS/AASS Chamber Temperature Range Ambient + 9

More information

Annex I Tested by (name + signature)...: Approved by (name + signature)...: Date of issue... : 22/11/2012. TUV RHEINLAND ITALIA S.r.l.

Annex I Tested by (name + signature)...: Approved by (name + signature)...: Date of issue... : 22/11/2012. TUV RHEINLAND ITALIA S.r.l. TEST REORT Rotating electrical machines art 5: Degrees of protection provided by the integral design of rotating electrical machines (I code) Classification Report Reference No....: 28105442 002 Annex

More information

CX5000 CAT 5e UTP System

CX5000 CAT 5e UTP System 3933 US Route 11 Cortland, NY 1345 Telephone: (67) 753-6711 Facsimile: (67) 758-3659 www.intertek.com pril 18, 213 Berk-Tek, Nexans Company 132 White Oak Road New Holland, P 17557 Test report number Project

More information

Verification/Report Number(s): HEARTWAY MEDICAL PRODUCTS Co., Ltd. Applicant Name/Address:

Verification/Report Number(s): HEARTWAY MEDICAL PRODUCTS Co., Ltd. Applicant Name/Address: Test Verification Of Conformity On the basis of the tests undertaken, the sample(s) of the below product have been found to comply with the essential requirements of the referenced specifications at the

More information

Certified Automotive Parts Association. Vehicle Test Fit Report. Report Number: HN-04060BBQ/COM VTF CAR Refit/ Tong Yang Industry Co.

Certified Automotive Parts Association. Vehicle Test Fit Report. Report Number: HN-04060BBQ/COM VTF CAR Refit/ Tong Yang Industry Co. Certified Automotive Parts Association Vehicle Test Fit Report Report Number: HN-04060BBQ/COM VTF CAR Refit/20140612 Tong Yang Industry Co., Ltd Mfr. Part Number: HN-04060BBQ Complaint Vehicle Test Fit

More information

CX6150 CAT 6 Enhanced UTP System

CX6150 CAT 6 Enhanced UTP System 3933 US Route 11 Cortland, NY 1345 Telephone: (67) 753-6711 Facsimile: (67) 758-3659 www.intertek.com July 7, 214 Berk-Tek, Nexans Company 132 White Oak Road New Holland, P 17557 Test report number Project

More information

ASTM B117 Testing Quality Control

ASTM B117 Testing Quality Control ASTM B117 Testing Quality Control ASTM B117 Testing, also known as a Standard Practice for Operating Salt Spray (Fog), is used to analyze relative corrosion for specimens of metals and coated metals exposed

More information

CS6700 CAT 6A SHIELDED SYSTEM

CS6700 CAT 6A SHIELDED SYSTEM 3933 US Route 11 Cortland, NY 13045 Telephone: (607) 753-6711 Facsimile: (607) 758-3659 www.intertek.com November 12, 2014 Berk-Tek, Nexans Company 132 White Oak Road New Holland, P 17557 Test report number

More information

CX6850 CAT 6A PREMIUM+ UTP SYSTEM

CX6850 CAT 6A PREMIUM+ UTP SYSTEM 3933 US Route 11 Cortland, NY 13045 Telephone: (607) 753-6711 Facsimile: (607) 758-3659 www.intertek.com November 12, 2014 Berk-Tek, Nexans Company 132 White Oak Road New Holland, P 17557 Test report number

More information

Test Report Number: G CRT-039f

Test Report Number: G CRT-039f 3933 US Route 11 Cortland, New York 145 Telephone: +1 () 345-3851 Facsimile: +1 (7) 758-6637 www.intertek.com Project Number: G28364 Certificate of Conformance Number: 324722CRT-1e Date Issued: 5/29/15

More information

TEST REPORT IEC Degrees of protection provided by enclosures ( Partially for IP65 test )

TEST REPORT IEC Degrees of protection provided by enclosures ( Partially for IP65 test ) TEST REPORT IEC 60529 Degrees of protection provided by enclosures ( Partially for IP65 test ) Report reference No...: L113061055 Compiled by (+ signature)...: see cover sheet... Approved by (+ signature)...:

More information

Report issued by: AUTHORISED FOR ISSUE:. Caroline Blenkhorn Section Head Appliances Department

Report issued by: AUTHORISED FOR ISSUE:. Caroline Blenkhorn Section Head Appliances Department Intertek Test Report 101575358MKS-001 Page 1 of 9 TEST REPORT Client: David Ayers, Karcher (UK) Ltd, Karcher House, Beaumont Road, Banbury, Oxon, OX16 1TB, UK Report issued by: Intertek Testing & Certification

More information

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-11321-02-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 20.12.2016 to 19.12.2021 Holder of certificate: TÜV

More information

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-20258-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 2016-02-02 to 2021-02-01 Holder of certificate: Amphenol-Tuchel

More information

MEASUREMENT AND TEST REPORT

MEASUREMENT AND TEST REPORT IES LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT For Guangzhou Hongli Opto-Electronic Co., Ltd. West side of Dongfeng Highway, Automobile industrial Base, Huadu

More information

TEST REPORT: CHM12-01-LSM

TEST REPORT: CHM12-01-LSM Date: Tel: +65 68851335 Fax: +65 67784301 Client s Ref: QM-0112-056 Email: Sihai.LI@tuv-sud-psb.sg Note: This report is issued subject to the Testing and Certification Regulations of the TÜV SÜD Group

More information

Environmental Test Report

Environmental Test Report Environmental Test Report Date: March 14, 2018 Report Number: R5597 Orbital ATK Alliant Techsystems Operations LLC 4700 Nathan Lane Plymouth, MN 55442 United States 3/14/2018 Prepared By: Jessica Tonz

More information

DILLARD S TEST PROTOCOL FOR DILR US LUGGAGE (V26)

DILLARD S TEST PROTOCOL FOR DILR US LUGGAGE (V26) Test Date: Reviewed By/Date: SUPPLEMENTAL PROTOCOLS DILLARD S TEST PROTOCOL FOR 1 The sample shall be reviewed against the requirements of California Proposition 65 to determine if additional testing or

More information

BRISTLE BLASTING SURFACE PREPARATION METHOD FOR MAINTENANCE. Neil Wilds

BRISTLE BLASTING SURFACE PREPARATION METHOD FOR MAINTENANCE. Neil Wilds Paper No. 09004 2009 BRISTLE BLASTING SURFACE PREPARATION METHOD FOR MAINTENANCE Neil Wilds International Paint Ltd., Protective Coatings Stoneygate Lane, Gateshead Tyne and Wear, NE10 0JY United Kingdom

More information

Test Summary Report for the Solid Wind Power SWP25-14TG20 Small Wind Turbine

Test Summary Report for the Solid Wind Power SWP25-14TG20 Small Wind Turbine Cleeve Road, Leatherhead Surrey, KT22 7SB UK Telephone: +44 (0) 1372 370900 Facsimile: +44 (0) 1372 370999 www.intertek.com Test Summary Report for the Solid Wind Power SWP25-14TG20 Small Wind Turbine

More information

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D PL 19102 01 00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 03.09.2013 to 02.09.2018 Holder of certificate: AUCOTEAM

More information

SGS Australia Pty Ltd

SGS Australia Pty Ltd TEST REPORT AS/NZS 60598.2.2:2001 Luminaires Part 2: Particular requirements Recessed luminaires Report Reference No....: S08007 Approved by (+ signature)...: I Absolom Date of issue...: Thursday, 31 January

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Charter Coating Service (2000) Ltd. Suite

More information

Center for Quality Engineering. Test Report No.: E0G90005

Center for Quality Engineering. Test Report No.: E0G90005 Center for Quality Engineering Order No.: E0G9 Pages: 14 Munich, Nov 30, 2011 Client: GE Intelligent Platforms GmbH & Co. KG Equipment Under Test: Wolverine 3 Manufacturer: Task: Test Specification(s):

More information

SHOCK TEST REPORT. Report No. : ENVA S9 Model Number : S9

SHOCK TEST REPORT. Report No. : ENVA S9 Model Number : S9 Report No. : ENVA10072605 S9 Model Number : S9 Page: 1 of 6 Product Name : S9 Model Number : S9 Date of Receipt : Jul. 26, 2010 Finished date of Test : Jul. 26, 2010 We, Spectrum Research & Testing Laboratory

More information

Approval mark PL HCR 1a A

Approval mark PL HCR 1a A Vehicle Technology Division THE NETHERLANDS (N E D E R L A N D) Concerning (1) - approval granted - approval extended - approval refused - approval withdrawn - production definitely discontinued COMMUNICATION

More information

CERTIFICATE of QUALITY TEST

CERTIFICATE of QUALITY TEST Test lab CERTIFICATE of QUALITY TEST according to DIN 55 350-18 - 4.3.4. DAP-PL-3439.00 Test report - No. 7564 / 09 Client FALCOM Wireless Communications GmbH Gewerbering 6 98704 Langenwiesen Equipment

More information

PRODUCT GUIDE: UNIVERSAL PRIMERS. Version:

PRODUCT GUIDE: UNIVERSAL PRIMERS. Version: PRODUCT GUIDE: UNIVERSAL PRIMERS Version: 08.07.17 EAGLE BRIDGES PRODUCT DATA SHEET PRODUCT: LIGHT GREY PRIMER Product Number: 2208-08 DESCRIPTION: A quick fast dry metal primer that was designed to have

More information

CALIBRATION REPORT. Rendered to: United States Aluminum Corp. LOCATION: Waxahachie, Texas

CALIBRATION REPORT. Rendered to: United States Aluminum Corp. LOCATION: Waxahachie, Texas CALIBRATION REPORT Rendered to: United States Aluminum Corp. LOCATION: Waxahachie, Texas Report No.: 79241.01-801-47 Calibration Date: 12/14/07 Report Date: 03/20/08 2865 Market Loop Southlake, Texas 76092

More information

IES LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES

IES LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES IES LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT For Guangzhou Hongli Opto-Electronic Co., Ltd. West side of Dongfeng Highway, Automobile industrial Base, Huadu

More information

B 344 PermaSleeve markers are supplied in roll form in a flattened format on a carrier designed for use with thermal transfer printers.

B 344 PermaSleeve markers are supplied in roll form in a flattened format on a carrier designed for use with thermal transfer printers. Technical Data Sheet BRADY B 344 FLUID RESISTANT PERMASLEEVE MARKER TDS No. B 344 Effective Date: 01/08/2014 Description: GENERAL Print Technology: Thermal Transfer Material Type: Irradiated polyolefin

More information

~;i~oi TEST REPORT REPORT NO. : 2006KLO603 PAGE: 1 OF 6. GROUP STEEL CORP. (M) SDN. BHD. 180 Kawasan Industri Ayer Keroh, Ayer Keroh, Melaka

~;i~oi TEST REPORT REPORT NO. : 2006KLO603 PAGE: 1 OF 6. GROUP STEEL CORP. (M) SDN. BHD. 180 Kawasan Industri Ayer Keroh, Ayer Keroh, Melaka SIRIM QAS International SdnBhd (CompanyNo: 41334-X) CHEMICAL TESTING SECTION, Building 16, No1, Persiaran Data' Menteri, POBox 735, Section 2,4911 Shah Alam, Selangor Daml Ehsan, Malaysia Tel no: 3-55446651/55446658/6662

More information

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D PL 11238 01 00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 09.02.2016 to 08.02.2021 Holder of certificate: ContiTech

More information

Test Report. for. Chilicon Power 1563 Calle Patricia Pacific Palisades, CA USA. Project Number: G Prepared By:

Test Report. for. Chilicon Power 1563 Calle Patricia Pacific Palisades, CA USA. Project Number: G Prepared By: Test Report for Chilicon Power 1563 Calle Patricia Pacific Palisades, CA 90272 USA Project Number: G100834560 Prepared By: Intertek 1500 Brigantine Drive Coquitlam, B.C. V3K 7C1 Canada Intertek Testing

More information

l-tech C O M P A N Y Issue by Engineering Department Product 8.4"Rugged LCD : Model WRD0840 Product Description Test Reason

l-tech C O M P A N Y Issue by Engineering Department Product 8.4Rugged LCD : Model WRD0840 Product Description Test Reason l-tech Thermal Test Report Issue by Engineering Department Product Model Product Description Report No:0807TT0239 8.4"Rugged LCD : WRD0840 New product Rugged Display A/D Board :i-tech / R5W-310 Rugged

More information

ShipRight Notice 1A for

ShipRight Notice 1A for ShipRight Notice 1A for Linked Supporting Services Planned Maintenance and Condition Monitoring, March 2013 The status of this ShipRight procedure is amended as shown and is now to be read in conjunction

More information

Standard Analysis Report

Standard Analysis Report Standard Analysis Report The status identifies the condition of the sample, Normal, Warning or Problem sample Laboratory sample number Clients details, equipment ID, Oil type and what compartment Date

More information

3M Connector System 0.050" x 0.100" Pitch. 3M Tripolarized Wiremount Socket - Series 820 3M 4-Wall, Tripolarized Header - Series 810

3M Connector System 0.050 x 0.100 Pitch. 3M Tripolarized Wiremount Socket - Series 820 3M 4-Wall, Tripolarized Header - Series 810 1 of 9 3M Connector System 0.050" x 0.100" Pitch 3M Tripolarized Wiremount Socket - Series 820 3M 4-Wall, Tripolarized Header - Series 810 Product Specification 78-5110-0074-0 Released: 10-1-10 2 of 9

More information

VIBRATION AND MECHANICAL SHOCK TEST REPORT

VIBRATION AND MECHANICAL SHOCK TEST REPORT Report No. :DH1701190024A-1 Version:A VIBRATION AND MECHANICAL SHOCK TEST REPORT Company :OTO Photonics Inc. Address :9F-5,No. 27, Guanxin Rd., East Dist., Hsinchu City 30072, Taiwan(R.O.C.) Sample Name

More information

ACCELERATED CORROSION TEST CHAMBERS

ACCELERATED CORROSION TEST CHAMBERS ACCELERATED CORROSION TEST CHAMBERS SALT SPRAY CYCLIC ACCT CCT CASS IMMERSION TANK SATURATED HUMIDITY KESTERNICH-SO 2 UV PROHESION GRAVELOMETER www.equilamna.com SALT SPRAY Industries Served: : Paint,

More information

Installation, Operating & Maintenance Instructions. All-metal gate valve with compact or extended pneumatic actuator

Installation, Operating & Maintenance Instructions. All-metal gate valve with compact or extended pneumatic actuator Installation, Operating & Maintenance Instructions All-metal gate valve with compact or extended pneumatic actuator Series 48 DN 16 320 mm (I.D. ⅝" 12") This manual is valid for the following product ordering

More information

Comparison of IG Testing Standard. IGMA Summer Meeting August 8, 2004

Comparison of IG Testing Standard. IGMA Summer Meeting August 8, 2004 Comparison of IG Testing Standard IGMA Summer Meeting August 8, 2004 1 The Task Compare the new Harmonized standards to: Old ASTM stds. Canadian stds. CEN stds. (Europe) ISO std. (proposed) 2 The Standards

More information

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan.

Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan. 11009797 002 age 1 of 11 TEST REORT Flat non-rewirable two-pole plugs, 2.5 A 250 V, with cord, for the connection of class II - equipment for household and similar purposes Report Reference No....: 11009797

More information

Test Report. E4S-Box V1.0

Test Report. E4S-Box V1.0 Test Report No. 05 / 5040-1-1a E4S-Box V1.0 S/N: 8 The results refer only to the tested equipment. Without written permission of the test laboratory it is allowed to publish parts of this test report.

More information

Analog Durometer Model AD-100

Analog Durometer Model AD-100 CHECK LINE BY ELECTROMATIC Analog Durometer Model AD-100 Operating Instructions Table of Contents 1.0 Introduction... 2 1.1 Unpacking 1.2 Complete Kit 2.0 Testing Procedure... 3 3.0 Memory Pointer... 4

More information

IEA SHC Task 27: Accelerated Aging of IG units: North American Test Methods

IEA SHC Task 27: Accelerated Aging of IG units: North American Test Methods IEA SHC Task 27: Accelerated Aging of IG units: North American Test Methods Hakim Elmahdy, Ph. D., MBA, P. Eng. Institute for Research in Construction National Research Council of Canada Introduction There

More information

PRODUCT EVALUATION REPORT

PRODUCT EVALUATION REPORT SPUTO AND LAMMERT ENGINEERING, LLC STRUCTURAL ENGINEERS 10 SW 1 ST AVENUE, GAINESVILLE, FL 32601 PHONE: 352-378-0448 FAX: 352-373-1331 E-MAIL: sputoandlammert@mindspring.com PRODUCT EVALUATION REPORT MANUFACTURER:

More information

TUFCOTE 3.3 PR HIGH SOLIDS FAST DRY ALKYD PRIMER (formerly DuPont 681 FD )

TUFCOTE 3.3 PR HIGH SOLIDS FAST DRY ALKYD PRIMER (formerly DuPont 681 FD ) TUFCOTE 3.3 PR (formerly DuPont 681 FD ) Tufcote 3.3 PR is an phenolic modified medium oil, lead and chromate free, single-package, VOC conforming primer (3.3 lbs./gal.) based on DuPont alkyd technology.

More information

Page 2 of 23 UNT150420C11

Page 2 of 23 UNT150420C11 Page 2 of 23 UNT150420C11 United Nations, Recommendations on the Transport of Dangerous Goods, Manual of Test and Criteria (Rev. 5 th, Amendment 2), Section 38.3 Report Reference No.... : Compiled by...

More information

MODEL FP-10. Read Instructions Carefully! CURTIS INSTRUMENTS, INC Kisco Ave. Mount Kisco, New York

MODEL FP-10. Read Instructions Carefully! CURTIS INSTRUMENTS, INC Kisco Ave. Mount Kisco, New York MODEL FP-10 CURTIS INSTRUMENTS, INC. 200 Kisco Ave. Mount Kisco, New York 10549 914-666-2971 www.curtisinstruments.com 53090 Rev A 11/16 Read Instructions Carefully! SAFETY INSTRUCTIONS This product was

More information

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For IESNA LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT For Room 316, Building 2, No.1, Xianke Yi Road, Huadong Town, Huadu District, Guangzhou, China Model:100B10C10(Ra2)

More information

1 / 33. TÜV Rheinland (Shanghai) Co., Ltd Solar/ Fuelcell Technologies. Test Report

1 / 33. TÜV Rheinland (Shanghai) Co., Ltd Solar/ Fuelcell Technologies. Test Report 1 / 33 TÜV Rheinland (Shanghai) Co., Ltd Solar/ Fuelcell Technologies Test Report Qualification of a Solar Collector in accordance with DIN EN 129751: 2011; DIN EN 129752: 2006 TÜV Report No.: 154035663_EN_ETC30_Report_Gao

More information

WESTONE ONYX BLACK WEI-408B2

WESTONE ONYX BLACK WEI-408B2 WESTONE ONYX BLACK WEI-408B2 DETECTING AND ANALYZING REPORT Series Number 2012 - (FX) -020 Samples Name Westone Onyx Black Roofing Slate WEI-408B2 Entrusting Organization Shaanxi Westone Industry and Trade

More information

The Scala Ladder System Leaning Ladders - Sliding Ladders - Hook-on Ladders 7.1

The Scala Ladder System Leaning Ladders - Sliding Ladders - Hook-on Ladders 7.1 The Scala Ladder System Leaning Ladders - Sliding Ladders - Hook-on Ladders : 7.1 The Scala ladder system Leaning Ladders - Sliding Ladders - Hook-on Ladders Our high quality, stainless steel ladders are

More information

FPD220 meter 2 di Dual-chamber orifice fitting with double isolation

FPD220 meter 2 di Dual-chamber orifice fitting with double isolation Data sheet DS/FPD220 EN FPD220 meter 2 di Dual-chamber orifice fitting with double isolation Measurement made easy Safety by design Double isolation with visible proofing mechanism meets HSG253 Category

More information

Krytox. Krytox XP Lubricants with Soluble Additives. performance lubricants. Product Information

Krytox. Krytox XP Lubricants with Soluble Additives. performance lubricants. Product Information e Product Information Krytox performance lubricants Krytox XP Lubricants with Soluble Additives Krytox XP lubricants are formulated using patented soluble additives. Typical perfluoropolyether (PFPE) greases

More information

600 Amp Surge Arrester

600 Amp Surge Arrester R&D Center 497 Schooley s Mountain Road Hackettstown, NJ 07840-3906 Tele: 908-852-1122 Fax: 908-813-2091 TEST REPORT NUMBER: 379-17-12164 DATE: 4-3-2012 REPORT OF TEST ON 600 Amp Surge Arrester Statements

More information

Photograph 1, Current feed to connector test loop

Photograph 1, Current feed to connector test loop Photograph 1, Current feed to connector test loop Photograph 2, control conductor and instrument leads outside test chamber Page 3 of 6 Photograph 3 Salt Fog Chamber with Connector Loop Photograph 4, Connector

More information

R E P O R T N U M B E R

R E P O R T N U M B E R R E P O R T N U M B E R 72128540 PREPARED FOR DURGIN AND CROWELL LUMBER CO. 231 FISCHER CORNER RD. NEW LONDON, NH 03257 ATTENTION JON BAKER PO# 061707 REPORT DATE JUNE 27, 2017 TÜV SÜD America, Inc. 1755

More information

ADD: Room New Victory House, Wing Lok Street, Central, HONG KONG

ADD: Room New Victory House, Wing Lok Street, Central, HONG KONG Customer Company & Address: GREEN CREATIVE ADD: Room 1206-7 New Victory House, 93-103 Wing Lok Street, Central, HONG KONG Contact Person: Guillaume Vidal Telephone: +86 21-62320308 Email address: guillaume@gc-lighting.com

More information

MATERIAL DATA SHEET TECHLITE LIGHT GREY ACOUSTICAL FOAM

MATERIAL DATA SHEET TECHLITE LIGHT GREY ACOUSTICAL FOAM TECHLITE Light Grey Acoustical Foam is a light-grey, open-cell foam made of melamine resin. TECHLITE is manufactured in the form of untrimmed blocks with a thin outer skin. The standard dimensions of the

More information

History. Quality Assurance. Applications. Protection against corrosion. Reduced installation

History. Quality Assurance. Applications. Protection against corrosion. Reduced installation 2 History The E-Klips spring steel fasteners range has been manufactured in the UK for over 25 years. Formely known as Furse Fastway they offer a quick, easy and reliable method of fixing services to steelwork

More information

SIGMAZINC 109. PRODUCT DATA SHEET January 16, 2015 (Revision of January 5, 2015) DESCRIPTION. Two-component, zinc-rich, polyamide-cured epoxy primer

SIGMAZINC 109. PRODUCT DATA SHEET January 16, 2015 (Revision of January 5, 2015) DESCRIPTION. Two-component, zinc-rich, polyamide-cured epoxy primer DESCRIPTION Two-component, zinc-rich, polyamide-cured epoxy primer PRINCIPAL CHARACTERISTICS Designed as a system primer for various paint systems Good corrosion prevention properties Quick-drying, can

More information

CONTINUOUS IMMERSION AND DUST TEST REPORT

CONTINUOUS IMMERSION AND DUST TEST REPORT Report No. :HS1404020081A Version:A CONTINUOUS IMMERSION AND DUST TEST REPORT Company Address :Taiway Electronics Components Co. :4F., No. 4, 6, 8, Lane 359, Sec. 2, Zhongshan Rd., Zhonghe Dist., New Taipei

More information

Alberta Innovates - Technology Futures ~ Fuels & Lubricants

Alberta Innovates - Technology Futures ~ Fuels & Lubricants Report To: 5 Kings College Road Toronto, Ontario, M5S 3G8 Attention: Curtis Wan E-mail: curtis.wan@utoronto.ca Fax: Alberta Innovates - Technology Futures ~ Fuels & Lubricants 250 Karl Clark Road, Edmonton,

More information

JET METER INSTRUCTIONS

JET METER INSTRUCTIONS UNPACKING Please open and inspect your package upon receipt. Your package was packed with great care and all the necessary packing materials to arrive to you undamaged. If you do find an item that is broken

More information

MILITARY SPECIFICATION CORROSION PREVENTIVE COMPOUNDS, WATER DISPLACING, ULTRA-THIN FILM PAGE 1

MILITARY SPECIFICATION CORROSION PREVENTIVE COMPOUNDS, WATER DISPLACING, ULTRA-THIN FILM PAGE 1 NOT MEASUREMENT SENSITIVE 26 November 1997 SUPERSEDING AMENDMENT 2 31 July 1996 MILITARY SPECIFICATION CORROSION PREVENTIVE COMPOUNDS, WATER DISPLACING, ULTRA-THIN FILM This amendment forms a part of,

More information

Cargo Handling Sheet. Methyl Ethyl Ketone (MEK) Document date: 3 June 2015 Revision 3

Cargo Handling Sheet. Methyl Ethyl Ketone (MEK) Document date: 3 June 2015 Revision 3 Cargo Handling Sheet Methyl Ethyl Ketone (MEK) Document date: 3 June 2015 Product Details: Product Name: Shipping Name: Chemical Family: Product Code: SDS: Methyl Ethyl Ketone Methyl Ethyl Ketone Ketone

More information

CITY OF ALLIANCE, OHIO 2016 CHEMICAL SUPPLIES SPECIFICATIONS FOR

CITY OF ALLIANCE, OHIO 2016 CHEMICAL SUPPLIES SPECIFICATIONS FOR CITY OF ALLIANCE, OHIO 2016 CHEMICAL SUPPLIES SPECIFICATIONS FOR ALUMINUM SULFATE, LIQUID CAUSTIC SODA, LIQUID CHLORINE ACTIVATED CARBON, POWDERED Minimum 800 Iodine Number ACTIVATED CARBON, POWDERED Minimum

More information

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue ENEC LICENCE Licence No. ENEC-01360 Page 1/3 Date of Issue 2016-03-04 Licence Holder WAGO KONTAKTTECHNIK GMBH & CO KG HANSASTRASSE 27 MINDEN, 32423 Germany Production site WAGO CONTACT SA ROUTE DE L'INDUSTRIE

More information

1P D 6681 Final Report Cover Sheet

1P D 6681 Final Report Cover Sheet D 6681 Final Report Cover Sheet Method Version Conducted For V = Valid I = Invalid N = Results Cannot be Interpreted as Representative of Oil Performance (Non- Reference Oil) and Shall Not be Used in Determining

More information

3M Three-Wall and Four-Wall Headers. Series 3XXX

3M Three-Wall and Four-Wall Headers. Series 3XXX 1 of 7 M Three-Wall and Four-Wall Headers Series XXX Product 78-10-0008-0 Released: 0-0-11 of 7 Table of Contents Section Page 1. Scope........ M Customer Documents....... Performance and Test Descriptions...

More information

Tests Windshield Mounting. according to. Federal Motor Vehicle Safety Standard 49 CFR (FMVSS 212)

Tests Windshield Mounting. according to. Federal Motor Vehicle Safety Standard 49 CFR (FMVSS 212) TÜV Rheinland Group Test Report No. 113XS0245-00 Test Item : 1 Hour Glass Bonding Adhesive 58015 and 50681 Vehicle : 2002 Ford Mondeo Applicant : EMFI S.A.S., 67501 Haguenau Cedex, France Documentation

More information

mga research corporation

mga research corporation mga research corporation UNDERGROUND TECHNOLOGIES MAN-HOLE CONSTRUCTION VERTICAL STATIC LOAD TEST SERIES (PO# 11521) 446 executive drive troy, mi 48083 248 / 577-5001 fax 248 / 577-5025 www.mgaresearch.com

More information

PRODUCT SPECIFICATION

PRODUCT SPECIFICATION ML-XT COMMERCIAL VEHICLE CONNECTOR SERIES 1.0 SCOPE This Product Specification relates to the ML-XT Commercial Vehicle, (CV), Power and/or Signal wire-to-wire connector system. This system consists of

More information

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance jhćmtc Test Report issued under the responsibility of: TEST REPORT IEC 60601-1 Part 1: General requirements for basic safety and essential performance Report Number.... : T223-0128/16 Date of issue...

More information

Cyclic Corrosion Chamber C.C.T AUTO Series

Cyclic Corrosion Chamber C.C.T AUTO Series Cyclic Corrosion Chamber C.C.T AUTO Series CCT 5000 AUTO image merely illustrative Cooling system image merely illustrative Specifications/ Models CCT 1300 AUTO CCT 3000 AUTO CCT 5000 AUTO Allows 7 different

More information

ELTAS Transformatör Sanayi Ve Ticaret Anonim Şirketi Izmir TURKEY. Fire behaviour test F1 class. Unit LABORATORIES Roberto Mariani

ELTAS Transformatör Sanayi Ve Ticaret Anonim Şirketi Izmir TURKEY. Fire behaviour test F1 class. Unit LABORATORIES Roberto Mariani Approved Page 1/16 Client ELTAS Transformatör Sanayi Ve Ticaret Anonim Şirketi Izmir TURKEY Test equipment Complete column of a three-phase 500 kva dry-type power transformer Tests carried out Fire behaviour

More information

TÜV NEDERLAND P.O. Box AC Best - The Netherlands De Waal 21C PH Best - The Netherlands +31 (0) (0)

TÜV NEDERLAND P.O. Box AC Best - The Netherlands De Waal 21C PH Best - The Netherlands +31 (0) (0) TÜV NEDERLAND P.O. Box 120-5680 AC Best - The Netherlands De Waal 21C - 5684 PH Best - The Netherlands +31 (0)499-339500 - +31 (0)499-339539 Pendulum impact testing on double bar gate type DG-950 (UDG-37)

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 DURHAM HOLDINGS CORPORATION INC. DBA MME TESTING 1039 Industrial Court Suwanee, GA 30024 Danny Collazo Phone: 678 730 2000 MECHANICAL Valid To: October 31,

More information

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For IESNA LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT For SHENZHEN MTC LIGHTING CO., LTD. NO.65,Chuangyi Road,Dalang Street,Baoan District,Shenzhen,GuangDong Province,CHINA

More information

Installation, Operating & Maintenance Instructions. HV gate valve with pneumatic actuator. Series 110 DN mm (I. D.

Installation, Operating & Maintenance Instructions. HV gate valve with pneumatic actuator. Series 110 DN mm (I. D. Installation, Operating & Maintenance Instructions HV gate valve with pneumatic actuator Series 110 DN 250 320 mm (I. D. 10" 12") This manual is valid for the following product ordering numbers: 11048-.

More information

Model D Spray Gun. Parts Identification Manual 2943J-ID. "Success through Unity" June 17, 2003 Issue 2 GUSMER CORPORATION

Model D Spray Gun. Parts Identification Manual 2943J-ID. Success through Unity June 17, 2003 Issue 2 GUSMER CORPORATION "Success through Unity" Model D Spray Gun Parts Identification Manual 2943J-ID June 17, 2003 Issue 2 GUSMER CORPORATION A Subsidiary of Gusmer Machinery Group, Inc. One Gusmer Drive Lakewood, New Jersey,

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 16059155 001 Date of issue... : Apr.24,

More information

DILLARD'S INC TEST PROTOCOL FOR DILL USA- (V13) KEYCHAIN / BATTERY OPERATED KEYCHAIN / KEYCHAIN WITH LIGHT

DILLARD'S INC TEST PROTOCOL FOR DILL USA- (V13) KEYCHAIN / BATTERY OPERATED KEYCHAIN / KEYCHAIN WITH LIGHT By/Date: Page 1 of 5 Criteria Notes esults ating SCOPE: This protocol is applicable for testing of keychain / battery operated keychain / keychain with light. SUPPLEMENTY POTOCOL Note: dditional cost,

More information

RAYMARK LABELS SCOPE. This Quality Assurance Specification establishes the quality standard for Tyco Raymark Labels

RAYMARK LABELS SCOPE. This Quality Assurance Specification establishes the quality standard for Tyco Raymark Labels RW 2518 Revision 1 Page 1 of 9 Date Printed 15-Apr-08 Tyco Electronics Cheney Manor, Swindon. UK RW 2518 Revision 1 RAYMARK LABELS SCOPE This Quality Assurance Specification establishes the quality standard

More information

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-18869-01-00 according to DIN EN ISO/IEC 17025:2005 Holder of certificate: ilf Forschungs- und Entwicklungsgesellschaft Lacke

More information

THERMAL SHOCK TEST REPORT

THERMAL SHOCK TEST REPORT Report No. :DH1509300024A Version:A THERMAL SHOCK TEST REPORT Company :FLIP CHIP OPTO. INC. Address :No.185, Kewang Rd., Longtan Dist., Taoyuan City 325, Taiwan (R.O.C.) Model Name :Apollo 600-B Lot Number

More information