1 SmartSensor 105 & Advance NEMA Salt Fog Test Report Wavetronix products mentioned: SmartSensor 105 SmartSensor Advance As contracted by Wavetronix, Environ Laboratories LLC performed a NEMA salt fog test on the SmartSensor 105 between April 7 and April 15, Since the SmartSensor 105 and SmartSensor Advance use the same hardware platform, this report applies to both products. The following report documents the results of the test and is unedited by Wavetronix. Environ Laboratories LLC 9725 Girard Avenue South Minneapolis, Minnesota WX
2 SALT FOG TEST for WAVETRONIX, LLC 5314 NORTH 250 WEST PROVO, UT PREPARED BY: Thomas P. Braun Test Engineer APPROVED BY: David M. Gillen Vice President This document shall not be reproduced except in full, without the written authorization of Environ Laboratories LLC. ENVIRON LABORATORIES LLC Page 1 of FAX
3 REVISION HISTORY Revision Total Number Date Description of Pages April 2003 Original ENVIRON LABORATORIES LLC Page 2 of 7
4 PREPARED FOR: WAVETRONIX, LLC 5314 NORTH 250 WEST PROVO, UT ATTN: Mr. Don Christensen TEST DATES: Start: 4/7/2003 Completion: 4/15/2003 ENVIRON TEST NO.: PURCHASE ORDER NO.: 4435 PURCHASE DATE: 3/19/2003 SALT FOG TEST 1.0 ABSTRACT 1.1 Object Subject one (1) Enclosure to a 4X Corrosion Protection (Salt Fog) Test in accordance with NEMA 250, Section 5.10, which references ASTM B Conclusions Upon completion of the test some corrosion was noted coming from the bolts holding the enclosure closed, but no other corrosion was found. This enclosure can be considered to have passed as NEMA 250 allows for corrosion where protection is considered impractical, such as machined and mating surfaces. The unit was returned to Wavetronix, LLC upon completion of the exposure. 2.0 UNIT(S) TESTED MANUFACTURER: DEVICE: MODEL/PART NO.: WAVETRONIX, LLC Enclosure Smart Sensor Housing SERIAL NO.: --- The results of this test apply only to the units identified in this Engineering Report by device identifier and model / part number, or serial number. ENVIRON LABORATORIES LLC Page 3 of 7
5 3.0 TEST REQUESTED Subject the test unit to a 4X Corrosion Resistance Test in accordance with NEMA 250, Section 5.10, which references ASTM B117. A 200-hour test shall be conducted as follows: ASTM B117 states the following conditions shall be met during the exposure period: 1. The salt solution shall be 5 parts, by weight, of sodium chloride dissolved in 95 parts distilled or de-ionized water. 2. The temperature in the exposure zone shall be between 92 F and 97 F. 3. The salt solution shall be atomized into the chamber at a rate that results in a salt fog fallout rate between 1.0 and 2.0 milliliters per hour per 80 square centimeters of horizontal collection area. 4. The collected fallout shall have a ph value between 6.5 and 7.2. Periodic checks shall be made throughout the exposure to assure no deviations from these parameters. 4.0 INSTRUMENTATION, PROCEDURE AND RESULTS 4.1 Instrumentation All instrumentation is calibrated regularly by instruments directly traceable to the National Institute of Standards and Technology, and in accordance with MIL-I-45208A, ANSI/NCSL Z and ISO/IEC 17025:1999. Equipment Number Description Manufacturer Model No. Last Calibration Due Calibration Range ph/ise Meter Orion 525A 8/23/2002 8/23/ to ph Hydrometer VWR Scientific /31/1998 8/31/ to Specific Gravity ENVIRON LABORATORIES LLC Page 4 of 7
6 Equipment Number Description Manufacturer Model No. Last Calibration Due Calibration Range Cyclic Corrosion Tester Q-PANEL CO. Q Fog / CCT1100 1/20/2003 7/20/2003 Temperature: Ambient to +160 F; Humidity: Ambient to 100%RH 4.2 Procedure The test unit was subjected to a 200-hour Salt Fog Test in accordance with Section 3.0 above. Checks made throughout the exposure period revealed no deviations from the ranges specified in Section 3.0. The test unit was placed in the salt fog chamber maintained at 95 F, and a 5% salt solution was then atomized into the chamber in a manner that achieved an hourly fallout rate between 1.0 and 2.0 ml per 80 cm 2 of horizontal collection area. These conditions were maintained for a period of 200 hours. Following completion of the exposure, the samples were lightly rinsed with deionized water at a temperature of less than 100 F and allowed to dry at lab ambient conditions. A post-test visual examination was then performed. 4.3 Results Upon completion of the test some corrosion was noted coming from the bolts holding the enclosure closed, but no other corrosion was found. This enclosure can be considered to have passed as NEMA 250 allows for corrosion where protection is considered impractical, such as machined and mating surfaces. The unit was returned to Wavetronix, LLC upon completion of the exposure. ENVIRON LABORATORIES LLC Page 5 of 7
7 Photograph No. 1 - Chamber setup ENVIRON LABORATORIES LLC Page 6 of 7
8 Photograph No. 2 - Post-test photo of an example of the bolt corrosion ENVIRON LABORATORIES LLC Page 7 of 7
Environmental Test Report
Environmental Test Report Date: March 14, 2018 Report Number: R5597 Orbital ATK Alliant Techsystems Operations LLC 4700 Nathan Lane Plymouth, MN 55442 United States 3/14/2018 Prepared By: Jessica Tonz
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 NATIONAL EXPOSURE TESTING, INC. 3211 Centennial Road Sylvania, OH 43560 Christa Lammers Phone: 419 841 1065 MECHANICAL Valid To: October 31, 2018 Certificate
More informationNo , Vers.1
Pag. 1 of 4 TEST REPORT No. Test performed in accordance with the standard ASTM B 117 (2003) issued by TÜV Rheinland Italia S.r.l. - Via Gavardina Trav. II, 42 I-25010 Ponte S. Marco (BS) 1. General information
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 NATIONAL EXPOSURE TESTING, INC. 3211 Centennial Road Sylvania, OH 43560 Christa Lammers Phone: 419 841 1065 MECHANICAL Valid To: October 31, 2016 Certificate
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. AUTO TECHNOLOGY COMPANY Progress Drive Strongsville, OH Kevin Smith MECHANICAL
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 AUTO TECHNOLOGY COMPANY 20026 Progress Drive Strongsville, OH 44149 Kevin Smith 440 572 7800 MECHANICAL Valid To: December 31, 2019 Certificate Number: 2563.02
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ELEMENT MATERIALS TECHNOLOGY MINNEAPOLIS LLC (A subsidiary of Element Materials Technology Minneapolis Inc.) 9725 Girard Avenue South Minneapolis, MN 55431
More informationE/ECE/324/Rev.1/Add.15/Rev.7/Corr.1 E/ECE/TRANS/505/Rev.1/Add.15/Rev.7/Corr.1
E/ECE/34/Rev.1/Add.15/Rev.7/Corr.1 5 November 01 Agreement Concerning the Adoption of Uniform Technical Prescriptions for Wheeled Vehicles, Equipment and Parts which can be fitted and/or be used on Wheeled
More informationENGINEERING AND TEST DIVISION CHURCH STREET, BOHEMIA, LONG ISLAND, NEW YORK (631)
DAYTON T. BROWNINC. Founded 1950 ENGINEERING AND TEST DIVISION CHURCH STREET, BOHEMIA, LONG ISLAND, NEW YORK 11716 (631) 589-6300 TEST REPORT NO: DBT04R99-1234 DAYTON T. BROWN, INC. JOB NO. 409817-00-000
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. AUTO TECHNOLOGY COMPANY Progress Drive Strongsville, OH Kevin Smith MECHANICAL
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 AUTO TECHNOLOGY COMPANY 20026 Progress Drive Strongsville, OH 44149 Kevin Smith 440 572 7800 MECHANICAL Valid To: December 31, 2013 Certificate Number: 2563.02
More information600 Amp Surge Arrester
R&D Center 497 Schooley s Mountain Road Hackettstown, NJ 07840-3906 Tele: 908-852-1122 Fax: 908-813-2091 TEST REPORT NUMBER: 379-17-12164 DATE: 4-3-2012 REPORT OF TEST ON 600 Amp Surge Arrester Statements
More informationTHERMAL SHOCK TEST REPORT
Report No. :DH1509300024A Version:A THERMAL SHOCK TEST REPORT Company :FLIP CHIP OPTO. INC. Address :No.185, Kewang Rd., Longtan Dist., Taoyuan City 325, Taiwan (R.O.C.) Model Name :Apollo 600-B Lot Number
More informationASTM B117 Testing Quality Control
ASTM B117 Testing Quality Control ASTM B117 Testing, also known as a Standard Practice for Operating Salt Spray (Fog), is used to analyze relative corrosion for specimens of metals and coated metals exposed
More informationLightweight Shock Test Report on Power Supply PS1503-H-MB and Adapter Plate for Powerstar Inc. Gaithersburg, MD
Test Report No. 11543.1 No. of Pages 14 Lightweight Shock Test Report on Power Supply PS1503-H-MB and Adapter Plate for Powerstar Inc. Gaithersburg, MD NU LABORATORIES 312 Old Allerton Road, Annandale,
More information2.0 TEST PROCEDURES AND RESULTS Vibration Test TEST EQUIPMENT AND INSTRUMENTATION QUALITY ASSURANCE PROGRAM 7 ATTACHMENTS
Page No. 2 TABLE OF CONTENTS Page No. 1.0 INTRODUCTION 3 1.1 Scope 3 1.2 References 3 1.3 Test Specimen Description 3 1.4 Summary 3 2.0 TEST PROCEDURES AND RESULTS 4 2.1 Vibration Test 4 3.0 TEST EQUIPMENT
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1, 2, 3 CONTINENTAL AUTOMOTIVE SYSTEMS 2400 Executive Hills Blvd. Auburn Hills, MI 48326 Mr. David E. Swift Phone: 248 209 3813 Email: david.swift@continental-corporation.com
More informationIES LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES
IES LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT For Guangzhou Hongli Opto-Electronic Co., Ltd. West side of Dongfeng Highway, Automobile industrial Base, Huadu
More informationVIA Platform Environmental Qualification Testing Standards
VIA Platform Environmental Qualification Testing Standards Revision: 1 Report Dated: September 7 th 2016 Report Prepared By: Noel Joyce Reliability Lab Manager Page 1 of 16 Table of Contents 1. Purpose...
More informationCyclic Corrosion Test CORR Series
Cyclic Corrosion Test CORR Series CCT 1300 CORR image merely illustrative Specifications/Model CCT 1300 CORR CCT 3000 CORR CCT 5000 CORR - Mode: SALT SPRAY / SALT FOG - Mode: WATER CONDENSATION HUMIDITY
More informationMEASUREMENT AND TEST REPORT
IES LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT For Guangzhou Hongli Opto-Electronic Co., Ltd. West side of Dongfeng Highway, Automobile industrial Base, Huadu
More informationPhotograph 1, Current feed to connector test loop
Photograph 1, Current feed to connector test loop Photograph 2, control conductor and instrument leads outside test chamber Page 3 of 6 Photograph 3 Salt Fog Chamber with Connector Loop Photograph 4, Connector
More informationReliability Test Report
Reliability Test Report Page 1 of 29 Reliability flow Chart: Page 2 of 29 Test Group 1 1.1 Dimensional Analysis: 1.1.1 Test Purpose: These measurements are to verify that the units meet the dimensional
More informationAUGUST 28, 2008 TEST REPORT # REV.1.1 MIXED FLOWING GAS TESTING CONNECTOR SERIES CLP S-D-A FTSH S-DV-A SAMTEC, INC.
AUGUST 28, 2008 TEST REPORT #208383-3 REV.1.1 MIXED FLOWING GAS TESTING CONNECTOR SERIES CLP-130-02-S-D-A FTSH-130-02-S-DV-A SAMTEC, INC. APPROVED BY: DOMINIC ARPINO PROGRAM MANAGER CONTECH RESEARCH, INC.
More informationAUGUST 28, 2008 TEST REPORT # REV.1.1 MIXED FLOWING GAS TESTING CONNECTOR SERIES SEM H-D-WT TEM H-D-WT SAMTEC, INC.
AUGUST 28, 2008 TEST REPORT #208383-5 REV.1.1 MIXED FLOWING GAS TESTING CONNECTOR SERIES SEM-125-02-03.0-H-D-WT TEM-125-02-03.0-H-D-WT SAMTEC, INC. APPROVED BY: DOMINIC ARPINO PROGRAM MANAGER CONTECH RESEARCH,
More informationAnnex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005
Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-20258-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 2016-02-02 to 2021-02-01 Holder of certificate: Amphenol-Tuchel
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 QUALITY CONTROL SERVICES, INC. 2340 SE 11 th Avenue Portland, OR 97214 George Cahill Phone: 503 236 2712 CALIBRATION Valid To: September
More informationSmartSensor HD Performance Test Results
Performance Test Results TEST REPORT In order to show compliance with specifications for bid submittal and verification purposes, several performance tests were conducted. The following sections contain
More informationMILITARY SPECIFICATION CORROSION PREVENTIVE COMPOUNDS, WATER DISPLACING, ULTRA-THIN FILM PAGE 1
NOT MEASUREMENT SENSITIVE 26 November 1997 SUPERSEDING AMENDMENT 2 31 July 1996 MILITARY SPECIFICATION CORROSION PREVENTIVE COMPOUNDS, WATER DISPLACING, ULTRA-THIN FILM This amendment forms a part of,
More informationCREEP PERFORMANCE TEST REPORT. Rendered to: TREX COMPANY LLC. Seclusions Composite Privacy Fence System TYPE: Composite Fence System
Architectural Testing CREEP PERFORMANCE TEST REPORT Rendered to: TREX COMPANY LLC Seclusions Composite Privacy Fence System TYPE: Composite Fence System Report No.: Report Date: Expiration Date: 130 Derry
More informationSalt Spray Test Chamber Model SSe CASS/AASS ASTM B 368 ISO 9227 JIZ 2371
Salt Spray Test Chamber Model SSe CASS/AASS ASTM B 368 ISO 9227 JIZ 2371 Specification/Model SS600e CASS/AASS SS1000e CASS/AASS SS1300e CASS/AASS SS3000e CASS/AASS Chamber Temperature Range Ambient + 9
More informationTHREE RANGE DS METERS Operation Instructions
THREE RANGE DS METERS Operation Instructions User Manual for Models 532T1 532T2 532M1245-25 2450 Impala Drive Carlsbad, CA 92010-7226 USA Tel 760-438-2021 Fax 800-869-7668 / 760-931-9189 www.myronl.com
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 DEKRA IST RELIABILITY SEVICES INC. No. 22 Puding Rd., East Dist. Hsinchu City 300, Taiwan, R.O.C. Phone: 886 3 579 5766 ext 7100 Mr. General Lee general.lee@dekra-ist.com
More informationPRODUCT SPECIFICATION
ML-XT COMMERCIAL VEHICLE CONNECTOR SERIES 1.0 SCOPE This Product Specification relates to the ML-XT Commercial Vehicle, (CV), Power and/or Signal wire-to-wire connector system. This system consists of
More informationAug07 Rev A All Paragraphs Revised
Qualification Test Report Universal MATE-N-LOK* Connector 110-213 28Aug07 Rev A All Paragraphs Revised 1. INTRODUCTION 1.1. Purpose 1.2. Scope Testing was performed on Universal MATE-N-LOK* connectors
More informationTemperature Life with or without Electrical Load Test Procedure for Electrical Connectors and Sockets
ANSI/EIA-364-17B-1999 Approved: April 23, 1999 EIA STANDARD EIA-364-17B TP-17B Temperature Life with or without Electrical Load Test Procedure for Electrical Connectors and Sockets EIA-364-17B (Revision
More informationRated voltage: 100~277 VAC Frequency: 50/60Hz Wattage: 14 W
Customer Company & Address: MaxLite ADD: 12 York Ave, West Caldwell, NJ 07006 Contact Person: Francisco Garza Telephone: 973-244-7300x142 Telephone: fgarza@maxlite.com Manufacturer: Country of Origin:
More informationACCELERATED CORROSION TEST CHAMBERS
ACCELERATED CORROSION TEST CHAMBERS SALT SPRAY CYCLIC ACCT CCT CASS IMMERSION TANK SATURATED HUMIDITY KESTERNICH-SO 2 UV PROHESION GRAVELOMETER www.equilamna.com SALT SPRAY Industries Served: : Paint,
More informationADD: Room New Victory House, Wing Lok Street, Central, HONG KONG
Customer Company & Address: GREEN CREATIVE ADD: Room 1206-7 New Victory House, 93-103 Wing Lok Street, Central, HONG KONG Contact Person: Guillaume Vidal Telephone: +86 21-62320308 Email address: guillaume@gc-lighting.com
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 NORTHERN BALANCE AND SCALE, INC. 9556 W. Bloomington Freeway Bloomington, MN 55431 Joey Kaluser Phone: 952 881 7716 CALIBRATION Valid
More informationSHOCK TEST REPORT. Report No. : ENVA S9 Model Number : S9
Report No. : ENVA10072605 S9 Model Number : S9 Page: 1 of 6 Product Name : S9 Model Number : S9 Date of Receipt : Jul. 26, 2010 Finished date of Test : Jul. 26, 2010 We, Spectrum Research & Testing Laboratory
More informationCONTINUOUS IMMERSION AND DUST TEST REPORT
Report No. :HS1404020081A Version:A CONTINUOUS IMMERSION AND DUST TEST REPORT Company Address :Taiway Electronics Components Co. :4F., No. 4, 6, 8, Lane 359, Sec. 2, Zhongshan Rd., Zhonghe Dist., New Taipei
More informationEMC and Durability Lab, HCL Technologies Ltd., #73-74, South Phase, Ambattur Industrial Estate, Chennai
Last Amended on - Page 1 of 10 I. EMI / EMC TESTS 1. IT Products / Household / Industrial / Medical / Network Telecommunications Equipment Radiated Emission Test (RE) CISPR11:2010 BSEN 55011:2010 CISPR22:2008
More informationTwo-Stroke-Cycle Gasoline Engine Lubricant Evaluation D4857 (Y350M2) ASTM TC Sequence I Test Procedure Title / Validity Declaration Page Form 1
Title / Validity Declaration Page Form 1 Version Conducted for I = Invalid V =Valid NR = Non-Reference Test Oil RO = Reference Oil Result EOT Time Reference Oil Formulation/Stand Alternate Codes Test Number
More informationClosed Cup Flash Point Tester
www.labtron.com info@labtron.com We have distinguished ranges of Closed Cup Flash Point Tester especially designed to offer highest level of accuracy and quality giving a versatility in the capacity and
More information8,1,8,1,2,7,2,7,6,3,6,3,4,5,4,5
\ 8,1,8,1,2,7,2,7,6,3,6,3,4,5,4,5 Marine Salt Testa Digital meter for the measurement of salinity, specific gravity and temperature Operation Manual 1. PRECAUTION The Marine Salt testa is for the sole
More informationCyclic Corrosion Chamber C.C.T AUTO Series
Cyclic Corrosion Chamber C.C.T AUTO Series CCT 5000 AUTO image merely illustrative Cooling system image merely illustrative Specifications/ Models CCT 1300 AUTO CCT 3000 AUTO CCT 5000 AUTO Allows 7 different
More information14 April 2016 Total Pages: 2. WET PENDULUM SLIP RESISTANCE Job No: M16/10016
ATTAR TEST REPORT NUMBER: 16/10016.2 The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. Accredited for compliance with
More informationTest Report Current (Gen 2) Pendant Armor and Gen 3 Pendant Armor Polymer A Hanger and Polymer B Hanger March 16, 2016 (Q022516U1R2) Testing Location
Client Roboworld Molded Products, LLC 8216 Pricinceton-Glendale Road, Suite 246 West Chester, OH 45069 Test Report Current (Gen 2) Pendant Armor and Gen 3 Pendant Armor Polymer A Hanger and Polymer B Hanger
More informationSPECIFICATION AND PERFORMANCE TABLE OF CONTENT. 1. Scope Reference Documents Material and Components... 2
TABLE OF CONTENT 1. Scope... 2 2. Reference Documents.. 2 3. Material and Components...... 2 4. Design and Construction..... 2 5. Rating.. 2 6. Performance and Test Descriptions. 2 7. Test Requirements
More informationGENERAL SPECIFICATION
ALPHA 2001 MD TMA (Truck Mounted Attenuator GENERAL SPECIFICATION I. GENERAL A. All ALPHA 2001 MD Truck Mounted Attenuators (ALPHA 2001 MD TMA) shall be designed and manufactured by Energy Absorption systems,
More informationFEBRRUARY 22, 2008 TEST REPORT # QSH/QTH/QTE SERIES CONNECTOR SHEAR TESTING SAMTEC, INC.
FEBRRUARY 22, 2008 TEST REPORT #207908 QSH/QTH/QTE SERIES CONNECTOR SHEAR TESTING SAMTEC, INC. APPROVED BY: DOMINIC ARPINO PROGRAM MANAGER CONTECH RESEARCH, INC. Contech Research REVISION HISTORY DATE
More informationTÜV NEDERLAND P.O. Box AC Best - The Netherlands De Waal 21C PH Best - The Netherlands +31 (0) (0)
TÜV NEDERLAND P.O. Box 120-5680 AC Best - The Netherlands De Waal 21C - 5684 PH Best - The Netherlands +31 (0)499-339500 - +31 (0)499-339539 Pendulum impact testing on double bar gate type DG-950 (UDG-37)
More informationD 5966 Roller Follower Wear Test. Final Report Cover Sheet. Report Packet Version No. Conducted For:
Final Report Cover Sheet Report Packet Version No. Conducted For: V = Valid I = Invalid Test Stand Stand Run Engine Engine Run A Alternate Codes Time Completed In my opinion this test been conducted in
More informationCLIMATE. Climate and temperature chambers.
Climate and temperature chambers. The Environmental Competence Centre has a number of climate chambers at its disposal to carry out low and high temperature tests, as well as a number of combined climate
More informationBante220 Portable ph Meter Instruction Manual
Bante220 Portable ph Meter Instruction Manual BANTE INSTRUMENTS CO., LTD Bante220 Portable ph Meter 1 Introduction Thank you for selecting the Bante220 portable ph meter. This manual provides a step-by-step
More informationVIBRATION AND MECHANICAL SHOCK TEST REPORT
Report No. :DH1701190024A-1 Version:A VIBRATION AND MECHANICAL SHOCK TEST REPORT Company :OTO Photonics Inc. Address :9F-5,No. 27, Guanxin Rd., East Dist., Hsinchu City 30072, Taiwan(R.O.C.) Sample Name
More informationENVIRONMENTAL TESTING
ENVIRONMENTAL TESTING Environmental Testing Foreword & Introduction Tests Heat - Cold - Climate Page 3 Thermal Shock Page 4 Low - High Pressure Page 4 Vibration Page 5 Mechanical Shock Page 6 Corrosive
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 LABORATORY SERVICES, PETROTRIN Southern Main Road Pointe-A-Pierre, Trinidad, Trinidad & Tobago Peter Bhim Phone: 868 658 4200 CHEMICAL Valid To: November 30,
More informationIESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For
IESNA LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT For Room 316, Building 2, No.1, Xianke Yi Road, Huadong Town, Huadu District, Guangzhou, China Model:100B10C10(Ra2)
More informationOPERATORS MANUAL FOR USE WITH MAGNETIC/HEATED STIRRER MG200
OPERATORS MANUAL FOR USE WITH MAGNETIC/HEATED STIRRER MG200 ISSUE 4 April 2007 TABLE OF CONTENTS Page 1.0. GENERAL INFORMATION 2 1.1. DEFINITION 2 1.2. PRINCIPE OF OPERATION 2 2.0. TECHNICAL DESCRIPTION
More informationINDEPENDENT TEST LABORATORY REPORT No A
Lighting Sciences, Inc. UL Verification Services 7826 E. Evans Rd. Scottsdale, Arizona 85260 USA P: 480-991-9260 F: 480-991-0375 lsi@ul.com www.lightingsciences.com Description: The sample(s) was(were)
More informationALPHA 70K TMA (Truck Mounted Attenuator) GENERAL SPECIFICATIONS
ALPHA 70K TMA (Truck Mounted Attenuator) GENERAL SPECIFICATIONS I. GENERAL A. All ALPHA 70K Truck Mounted Attenuators (ALPHA 70K TMA) shall be designed and manufactured by Energy Absorption Systems, Incorporated,
More informationHigh Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph
Application Note Petrochemicas High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph Author James D. McCurry, Ph.D. Agilent Technologies, Inc. Abstract An Agilent
More informationACCURACY RELIABILITY SIMPLICITY
PoolMeter Model 512T5D Operation Manual 05 July 09 ACCURACY RELIABILITY SIMPLICITY Water Quality Instrumentation Accuracy Reliability Simplicity DESCRIPTION This manual describes your Myron L 512T5D Dual
More informationPhysical Properties of Window Films
Physical Properties of Window Films Name 3M Renewable Energy Date: July 3, 20104 Attn: Paul Neumann Revision Date: September 18, 2014 Address: 3M Center, 235-3D-02 Author: William Stegeman City, State,
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 & ANSI/NCSL Z540-1-1994 EUSTIS CO., INC./PYROCOM CALIBRATION LAB 12407-B Mukilteo Speedway Lynnwood, WA 98087 Bill LeMesurier Phone: 425 423 9996 CALIBRATION
More informationTHERMOELECTRIC SAMPLE CONDITIONER SYSTEM (TESC)
THERMOELECTRIC SAMPLE CONDITIONER SYSTEM (TESC) FULLY AUTOMATED ASTM D2983 CONDITIONING AND TESTING ON THE CANNON TESC SYSTEM WHITE PAPER A critical performance parameter for transmission, gear, and hydraulic
More informationLightweight Shock and Type I Vibration Test Report on UPS Model No. PS3200RM for Powerstar Inc. Gaithersburg, MD
Test Report No. 12069.1 No. of Pages 21 Lightweight Shock and Type I Vibration Test Report on UPS Model No. PS3200RM for Powerstar Inc. Gaithersburg, MD NU LABORATORIES 312 Old Allerton Road, Annandale,
More informationREPORT NO. TR-P NC SAFETY COMPLIANCE TESTING FOR FMVSS 223 REAR IMPACT GUARDS 2007 TRANSFREIGHT TECHNOLOGY NHTSA NO.
REPORT NO. SAFETY COMPLIANCE TESTING FOR FMVSS 223 REAR IMPACT GUARDS 2007 TRANSFREIGHT TECHNOLOGY NHTSA NO. RIG 009 PREPARED BY: KARCO ENGINEERING, LLC. 9270 HOLLY ROAD ADELANTO, CALIFORNIA 92301 SEPTEMBER
More informationReport of Inspection
P. O. Box 8238 Searcy, AR 72145 866.811.5237 / 501.279.1166 Fax: 501.279.1225 As required by NFPA 1911 19.3: CFS Inspections is accredited to the requirements of ISO/IEC 17020. Report of Inspection SAFET
More informationIESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For
IESNA LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT For Guangzhou Hongli Opto-Electronic Co., Ltd. No.1, Xianke Yi Road, Huadong Town, Huadu District, Guangzhou,
More informationBERKELEY ANALYTICAL 815 Harbour Way South, Suite 6 Richmond, CA Ph ; Fax
BERKELEY ANALYTICAL 815 Harbour Way South, Suite 6 Richmond, CA 94804-3614 Ph. 510-236-2325; Fax 510-236-2335 E-mail info@berkeleyanalytical.com Product Sample Formaldehyde Emissions Customer & Building
More informationAn Automated System for the Acoustical and Aerodynamic Characterization of Small Air Moving Devices
Minneapolis, Minnesota NOISE-CON 2005 2005 October 17-19 An Automated System for the Acoustical and Aerodynamic Characterization of Small Air Moving Devices Jeff G. Schmitt David A. Nelson John Phillips
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 INDEPENDENT ENGINEERING LABORATORIES, INC. 1 2400 E. South Street Jackson, MI 49201 Ms. Jessica Stremich Phone: 517 788 6590 E-mail: IELaccounting@ielinc.com
More informationSequence VH Report Forms Version Conducted For
Report Forms Version Conducted For V = Valid I = Invalid N = Results cannot be interpreted as representative of oil performance (Non-Reference Oil) and shall not be used in determining an average test
More informationSGS TEST REPORT. Page: 1 of 6 Date: April 20, itech Company LLC Christy Street, Fremont CA USA
Page: 1 of 6 Date: April 20, 2010 itech Company LLC 41758 Christy Street, Fremont CA 94538 USA The following merchandise was submitted and identified by the vendor as: Product Description: 20.1 Multimedia
More informationLaboratory Report. U. S. Department of Justice
U. S. Department of Justice Laboratory Report To: SA CFI Richard Chandler Detroit Field Division 432 N. Saginaw Street Suite 605 Flint, Michigan 48502 Date of Report: Lab Number: 10F0052-1 Reference: 774040110026
More informationFlow Research and Test Center
SALES BULLETIN Flow Research and Test Center CREATING RESOURCE TECHNOLOGY FOR TODAY AND TOMORROW The key to FMC Technologies success has been its ability to provide the latest technology in products and
More informationSGO Series. SHEL LAB Gravity Convection Laboratory Ovens SGO1 SGO3 SGO5
SGO Series SHEL LAB Gravity Convection Laboratory Ovens SGO1 SGO3 Ideal for Industrial, Analytical, and General Laboratory Applications SHEL LAB Gravity Convention Laboratory Ovens are recommended for
More informationDUCOM HIGH FREQUENCY RECIPROCATING RIG
DUCOM HIGH FREQUENCY RECIPROCATING RIG Product information sheet Asia 477/A, 4 th Phase, Peenya industrial area,bangalore-560 058,India Phone: +91-80-4080-5555 Fax: +91-80-4080-5510 America 620, Johnson
More informationCertificate of Accreditation
Certificate of Accreditation ISO/IEC 17025:2005 Certificate Number L2264.03 Analysts, Inc. 2450 Hassell Road Hoffman Estates IL 60195 has met the requirements set forth in L-A-B s policies and procedures,
More informationWET PENDULUM SLIP RESISTANCE Job No: M14/7986
ATTAR TEST REPORT NUMBER: 14/7986 The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. Accredited for compliance with ISO/IEC
More informationNATIONAL TECHNICAL SYSTEMS
Test Report Number 41418-09.PPC Testing of Pancake Alternator & PMU PREPARED FOR: The Perfect Parts Company Sullivan Products 1 North Haven Street Baltimore, MD 21224 PREPARED BY: National Technical Systems
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ELITE ELECTRONIC ENGINEERING, INC. 1 1516 Centre Circle Downers Grove, IL 60515 Larry Brooks (QA Manager) Phone: 630 495 9770 ext. 166 Email: lbrooks@elitetest.com
More informationPH20 Value ph Tester Instruction Manual
PH20 Value ph Tester Instruction Manual APERA INSTRUMENTS, LLC www.aperainst.com v 3.3 1 1. Battery Installation Please install batteries according to the following steps. *Please note the correct direction
More information1P D 6681 Final Report Cover Sheet
D 6681 Final Report Cover Sheet Method Version Conducted For V = Valid I = Invalid N = Results Cannot be Interpreted as Representative of Oil Performance (Non- Reference Oil) and Shall Not be Used in Determining
More informationSM1206 Series. Overload Interrupt Time (Second) Nominal Rating - Note 2. Cold Resistance (Ohm) Note 1. Maximum I 2 T (Ampere 2 Second) Nominal Rating
SM1206 Series Part Numbering System SM1206-32 - 1.0 Fuse Type Voltage Amp Part Number/Rating Cold Resistance (Ohm) Note 1 Overload Interrupt Time (Second) Nominal Rating - Note 2 Maximum I 2 T (Ampere
More informationQualification of a precision pattern dispenser
Qualification of a precision pattern dispenser Raf Van Ammel, Katarzyna Sobiech-Matura, Uwe Wätjen 2016 EUR 28268 EN This publication is a Technical report by the Joint Research Centre, the European Commission
More informationCompliance Test Results. of Independently Manufactured. Automotive Replacement Headlamps. to FMVSS 108. Study I. March 18, 2003
Compliance Test Results of Independently Manufactured Automotive Replacement Headlamps to FMVSS 108 Study I March 18, 2003 Prepared By Certified Automotive Parts Association 1518 K Street NW, Suite 306
More informationTest Report. for. Chilicon Power 1563 Calle Patricia Pacific Palisades, CA USA. Project Number: G Prepared By:
Test Report for Chilicon Power 1563 Calle Patricia Pacific Palisades, CA 90272 USA Project Number: G100834560 Prepared By: Intertek 1500 Brigantine Drive Coquitlam, B.C. V3K 7C1 Canada Intertek Testing
More information1 st Quarter Summary of Meteorological and Ambient Air Quality Data Kennecott Utah Copper Monitoring Stations. Prepared for:
1 st Quarter 2018 Summary of Meteorological and Ambient Air Quality Data Kennecott Utah Copper Monitoring Stations Prepared for: Prepared by: Mr. Bryce C. Bird Director Division of Air Quality 195 North
More informationmga research corporation
mga research corporation UNDERGROUND TECHNOLOGIES MAN-HOLE CONSTRUCTION VERTICAL STATIC LOAD TEST SERIES (PO# 11521) 446 executive drive troy, mi 48083 248 / 577-5001 fax 248 / 577-5025 www.mgaresearch.com
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 METTLER TOLEDO (INDUSTRIAL) 1900 Polaris Parkway Columbus, OH 43240 Frank Gardone Phone: 412 213 2263 CALIBRATION Valid To: April 30,
More informationSchedule. 200 C to 400 C. 400 C to 660 C C to 800 C C to 1300 C C to 1200 C. 0 C to 1700 C. 0 C to 1700 C.
Page: 1 of 9 LABORATORY LOCATION: (PERMANENT LABORATORY) PPCALIBRATION SERVICES SDN. BHD. NO. 15, MEDAN BUKIT EMAS PUSAT PERNIAGAAN BUKIT EMAS 14000 BUKIT MERTAJAM, PULAU PINANG MALAYSIA This laboratory
More informationTMS CABLE MARKERS CM-SCE & CM-SCE-TP. Tie on Identification Product
Page 1 of 12 October 2015 Specification RW-2513 Document Number: 108-121016 TMS CABLE MARKERS CM-SCE & CM-SCE-TP Including HL cable marker range Tie on Identification Product SCOPE This quality assurance
More informationSafe-Stop TMA (Truck Mounted Attenuator) GENERAL SPECIFICATIONS
Safe-Stop TMA (Truck Mounted Attenuator) GENERAL SPECIFICATIONS I. GENERAL A. All Safe-Stop Truck Mounted Attenuators (Safe-Stop TMA) shall be designed and manufactured by Energy Absorption Systems, Incorporated,
More informationCree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL13048-001A CR4T-790L-27K-12-E26GU24 Date: 08/22/18 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Tammy Lehrmann
More informationCree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report
Report Number: Model: PL09173-004B IG-NM-5S-A-30K-UL-WH xxx Date: 09/21/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Zongjie
More informationBQ-9000 Quality Management System. Accredited Producer Requirements
BQ-9000 Quality Management System Accredited Producer Requirements Revision 4 Effective Date: February 1, 2007 This requirements document has been prepared by the National Biodiesel Accreditation Commission,
More informationAIIPA Standardized Best Practices Recommendations
AIIPA Standardized Best Practices Recommendations AIIPA recognizes that BAIIDS programs differ from state or jurisdictions for a variety of reasons. Differences will be found in regard to legal issues
More informationPROVIDING ACCURATE DATA IN A TIMELY MANNER
PROVIDING ACCURATE DATA IN A TIMELY MANNER 248 Hughes Lane St. Charles MO 63301 Ph. (636) 949-5835 Fax (636) 723-5835 www.elteklabs.com MATERIAL PROPERTIES LAB TRACKING TESTS TEST METHOD UL 746-A Section
More information