1 SmartSensor 105 & Advance NEMA Salt Fog Test Report Wavetronix products mentioned: SmartSensor 105 SmartSensor Advance As contracted by Wavetronix, Environ Laboratories LLC performed a NEMA salt fog test on the SmartSensor 105 between April 7 and April 15, Since the SmartSensor 105 and SmartSensor Advance use the same hardware platform, this report applies to both products. The following report documents the results of the test and is unedited by Wavetronix. Environ Laboratories LLC 9725 Girard Avenue South Minneapolis, Minnesota WX

2 SALT FOG TEST for WAVETRONIX, LLC 5314 NORTH 250 WEST PROVO, UT PREPARED BY: Thomas P. Braun Test Engineer APPROVED BY: David M. Gillen Vice President This document shall not be reproduced except in full, without the written authorization of Environ Laboratories LLC. ENVIRON LABORATORIES LLC Page 1 of FAX

3 REVISION HISTORY Revision Total Number Date Description of Pages April 2003 Original ENVIRON LABORATORIES LLC Page 2 of 7

4 PREPARED FOR: WAVETRONIX, LLC 5314 NORTH 250 WEST PROVO, UT ATTN: Mr. Don Christensen TEST DATES: Start: 4/7/2003 Completion: 4/15/2003 ENVIRON TEST NO.: PURCHASE ORDER NO.: 4435 PURCHASE DATE: 3/19/2003 SALT FOG TEST 1.0 ABSTRACT 1.1 Object Subject one (1) Enclosure to a 4X Corrosion Protection (Salt Fog) Test in accordance with NEMA 250, Section 5.10, which references ASTM B Conclusions Upon completion of the test some corrosion was noted coming from the bolts holding the enclosure closed, but no other corrosion was found. This enclosure can be considered to have passed as NEMA 250 allows for corrosion where protection is considered impractical, such as machined and mating surfaces. The unit was returned to Wavetronix, LLC upon completion of the exposure. 2.0 UNIT(S) TESTED MANUFACTURER: DEVICE: MODEL/PART NO.: WAVETRONIX, LLC Enclosure Smart Sensor Housing SERIAL NO.: --- The results of this test apply only to the units identified in this Engineering Report by device identifier and model / part number, or serial number. ENVIRON LABORATORIES LLC Page 3 of 7

5 3.0 TEST REQUESTED Subject the test unit to a 4X Corrosion Resistance Test in accordance with NEMA 250, Section 5.10, which references ASTM B117. A 200-hour test shall be conducted as follows: ASTM B117 states the following conditions shall be met during the exposure period: 1. The salt solution shall be 5 parts, by weight, of sodium chloride dissolved in 95 parts distilled or de-ionized water. 2. The temperature in the exposure zone shall be between 92 F and 97 F. 3. The salt solution shall be atomized into the chamber at a rate that results in a salt fog fallout rate between 1.0 and 2.0 milliliters per hour per 80 square centimeters of horizontal collection area. 4. The collected fallout shall have a ph value between 6.5 and 7.2. Periodic checks shall be made throughout the exposure to assure no deviations from these parameters. 4.0 INSTRUMENTATION, PROCEDURE AND RESULTS 4.1 Instrumentation All instrumentation is calibrated regularly by instruments directly traceable to the National Institute of Standards and Technology, and in accordance with MIL-I-45208A, ANSI/NCSL Z and ISO/IEC 17025:1999. Equipment Number Description Manufacturer Model No. Last Calibration Due Calibration Range ph/ise Meter Orion 525A 8/23/2002 8/23/ to ph Hydrometer VWR Scientific /31/1998 8/31/ to Specific Gravity ENVIRON LABORATORIES LLC Page 4 of 7

6 Equipment Number Description Manufacturer Model No. Last Calibration Due Calibration Range Cyclic Corrosion Tester Q-PANEL CO. Q Fog / CCT1100 1/20/2003 7/20/2003 Temperature: Ambient to +160 F; Humidity: Ambient to 100%RH 4.2 Procedure The test unit was subjected to a 200-hour Salt Fog Test in accordance with Section 3.0 above. Checks made throughout the exposure period revealed no deviations from the ranges specified in Section 3.0. The test unit was placed in the salt fog chamber maintained at 95 F, and a 5% salt solution was then atomized into the chamber in a manner that achieved an hourly fallout rate between 1.0 and 2.0 ml per 80 cm 2 of horizontal collection area. These conditions were maintained for a period of 200 hours. Following completion of the exposure, the samples were lightly rinsed with deionized water at a temperature of less than 100 F and allowed to dry at lab ambient conditions. A post-test visual examination was then performed. 4.3 Results Upon completion of the test some corrosion was noted coming from the bolts holding the enclosure closed, but no other corrosion was found. This enclosure can be considered to have passed as NEMA 250 allows for corrosion where protection is considered impractical, such as machined and mating surfaces. The unit was returned to Wavetronix, LLC upon completion of the exposure. ENVIRON LABORATORIES LLC Page 5 of 7

7 Photograph No. 1 - Chamber setup ENVIRON LABORATORIES LLC Page 6 of 7

8 Photograph No. 2 - Post-test photo of an example of the bolt corrosion ENVIRON LABORATORIES LLC Page 7 of 7

Environmental Test Report

Environmental Test Report Environmental Test Report Date: March 14, 2018 Report Number: R5597 Orbital ATK Alliant Techsystems Operations LLC 4700 Nathan Lane Plymouth, MN 55442 United States 3/14/2018 Prepared By: Jessica Tonz

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 NATIONAL EXPOSURE TESTING, INC. 3211 Centennial Road Sylvania, OH 43560 Christa Lammers Phone: 419 841 1065 MECHANICAL Valid To: October 31, 2018 Certificate

More information

No , Vers.1

No , Vers.1 Pag. 1 of 4 TEST REPORT No. Test performed in accordance with the standard ASTM B 117 (2003) issued by TÜV Rheinland Italia S.r.l. - Via Gavardina Trav. II, 42 I-25010 Ponte S. Marco (BS) 1. General information

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 NATIONAL EXPOSURE TESTING, INC. 3211 Centennial Road Sylvania, OH 43560 Christa Lammers Phone: 419 841 1065 MECHANICAL Valid To: October 31, 2016 Certificate

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. AUTO TECHNOLOGY COMPANY Progress Drive Strongsville, OH Kevin Smith MECHANICAL

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. AUTO TECHNOLOGY COMPANY Progress Drive Strongsville, OH Kevin Smith MECHANICAL SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 AUTO TECHNOLOGY COMPANY 20026 Progress Drive Strongsville, OH 44149 Kevin Smith 440 572 7800 MECHANICAL Valid To: December 31, 2019 Certificate Number: 2563.02

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ELEMENT MATERIALS TECHNOLOGY MINNEAPOLIS LLC (A subsidiary of Element Materials Technology Minneapolis Inc.) 9725 Girard Avenue South Minneapolis, MN 55431

More information

E/ECE/324/Rev.1/Add.15/Rev.7/Corr.1 E/ECE/TRANS/505/Rev.1/Add.15/Rev.7/Corr.1

E/ECE/324/Rev.1/Add.15/Rev.7/Corr.1 E/ECE/TRANS/505/Rev.1/Add.15/Rev.7/Corr.1 E/ECE/34/Rev.1/Add.15/Rev.7/Corr.1 5 November 01 Agreement Concerning the Adoption of Uniform Technical Prescriptions for Wheeled Vehicles, Equipment and Parts which can be fitted and/or be used on Wheeled

More information

ENGINEERING AND TEST DIVISION CHURCH STREET, BOHEMIA, LONG ISLAND, NEW YORK (631)

ENGINEERING AND TEST DIVISION CHURCH STREET, BOHEMIA, LONG ISLAND, NEW YORK (631) DAYTON T. BROWNINC. Founded 1950 ENGINEERING AND TEST DIVISION CHURCH STREET, BOHEMIA, LONG ISLAND, NEW YORK 11716 (631) 589-6300 TEST REPORT NO: DBT04R99-1234 DAYTON T. BROWN, INC. JOB NO. 409817-00-000

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. AUTO TECHNOLOGY COMPANY Progress Drive Strongsville, OH Kevin Smith MECHANICAL

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. AUTO TECHNOLOGY COMPANY Progress Drive Strongsville, OH Kevin Smith MECHANICAL SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 AUTO TECHNOLOGY COMPANY 20026 Progress Drive Strongsville, OH 44149 Kevin Smith 440 572 7800 MECHANICAL Valid To: December 31, 2013 Certificate Number: 2563.02

More information

600 Amp Surge Arrester

600 Amp Surge Arrester R&D Center 497 Schooley s Mountain Road Hackettstown, NJ 07840-3906 Tele: 908-852-1122 Fax: 908-813-2091 TEST REPORT NUMBER: 379-17-12164 DATE: 4-3-2012 REPORT OF TEST ON 600 Amp Surge Arrester Statements

More information

THERMAL SHOCK TEST REPORT

THERMAL SHOCK TEST REPORT Report No. :DH1509300024A Version:A THERMAL SHOCK TEST REPORT Company :FLIP CHIP OPTO. INC. Address :No.185, Kewang Rd., Longtan Dist., Taoyuan City 325, Taiwan (R.O.C.) Model Name :Apollo 600-B Lot Number

More information

ASTM B117 Testing Quality Control

ASTM B117 Testing Quality Control ASTM B117 Testing Quality Control ASTM B117 Testing, also known as a Standard Practice for Operating Salt Spray (Fog), is used to analyze relative corrosion for specimens of metals and coated metals exposed

More information

Lightweight Shock Test Report on Power Supply PS1503-H-MB and Adapter Plate for Powerstar Inc. Gaithersburg, MD

Lightweight Shock Test Report on Power Supply PS1503-H-MB and Adapter Plate for Powerstar Inc. Gaithersburg, MD Test Report No. 11543.1 No. of Pages 14 Lightweight Shock Test Report on Power Supply PS1503-H-MB and Adapter Plate for Powerstar Inc. Gaithersburg, MD NU LABORATORIES 312 Old Allerton Road, Annandale,

More information

2.0 TEST PROCEDURES AND RESULTS Vibration Test TEST EQUIPMENT AND INSTRUMENTATION QUALITY ASSURANCE PROGRAM 7 ATTACHMENTS

2.0 TEST PROCEDURES AND RESULTS Vibration Test TEST EQUIPMENT AND INSTRUMENTATION QUALITY ASSURANCE PROGRAM 7 ATTACHMENTS Page No. 2 TABLE OF CONTENTS Page No. 1.0 INTRODUCTION 3 1.1 Scope 3 1.2 References 3 1.3 Test Specimen Description 3 1.4 Summary 3 2.0 TEST PROCEDURES AND RESULTS 4 2.1 Vibration Test 4 3.0 TEST EQUIPMENT

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1, 2, 3 CONTINENTAL AUTOMOTIVE SYSTEMS 2400 Executive Hills Blvd. Auburn Hills, MI 48326 Mr. David E. Swift Phone: 248 209 3813 Email: david.swift@continental-corporation.com

More information

IES LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES

IES LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES IES LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT For Guangzhou Hongli Opto-Electronic Co., Ltd. West side of Dongfeng Highway, Automobile industrial Base, Huadu

More information

VIA Platform Environmental Qualification Testing Standards

VIA Platform Environmental Qualification Testing Standards VIA Platform Environmental Qualification Testing Standards Revision: 1 Report Dated: September 7 th 2016 Report Prepared By: Noel Joyce Reliability Lab Manager Page 1 of 16 Table of Contents 1. Purpose...

More information

Cyclic Corrosion Test CORR Series

Cyclic Corrosion Test CORR Series Cyclic Corrosion Test CORR Series CCT 1300 CORR image merely illustrative Specifications/Model CCT 1300 CORR CCT 3000 CORR CCT 5000 CORR - Mode: SALT SPRAY / SALT FOG - Mode: WATER CONDENSATION HUMIDITY

More information

MEASUREMENT AND TEST REPORT

MEASUREMENT AND TEST REPORT IES LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT For Guangzhou Hongli Opto-Electronic Co., Ltd. West side of Dongfeng Highway, Automobile industrial Base, Huadu

More information

Photograph 1, Current feed to connector test loop

Photograph 1, Current feed to connector test loop Photograph 1, Current feed to connector test loop Photograph 2, control conductor and instrument leads outside test chamber Page 3 of 6 Photograph 3 Salt Fog Chamber with Connector Loop Photograph 4, Connector

More information

Reliability Test Report

Reliability Test Report Reliability Test Report Page 1 of 29 Reliability flow Chart: Page 2 of 29 Test Group 1 1.1 Dimensional Analysis: 1.1.1 Test Purpose: These measurements are to verify that the units meet the dimensional

More information

AUGUST 28, 2008 TEST REPORT # REV.1.1 MIXED FLOWING GAS TESTING CONNECTOR SERIES CLP S-D-A FTSH S-DV-A SAMTEC, INC.

AUGUST 28, 2008 TEST REPORT # REV.1.1 MIXED FLOWING GAS TESTING CONNECTOR SERIES CLP S-D-A FTSH S-DV-A SAMTEC, INC. AUGUST 28, 2008 TEST REPORT #208383-3 REV.1.1 MIXED FLOWING GAS TESTING CONNECTOR SERIES CLP-130-02-S-D-A FTSH-130-02-S-DV-A SAMTEC, INC. APPROVED BY: DOMINIC ARPINO PROGRAM MANAGER CONTECH RESEARCH, INC.

More information

AUGUST 28, 2008 TEST REPORT # REV.1.1 MIXED FLOWING GAS TESTING CONNECTOR SERIES SEM H-D-WT TEM H-D-WT SAMTEC, INC.

AUGUST 28, 2008 TEST REPORT # REV.1.1 MIXED FLOWING GAS TESTING CONNECTOR SERIES SEM H-D-WT TEM H-D-WT SAMTEC, INC. AUGUST 28, 2008 TEST REPORT #208383-5 REV.1.1 MIXED FLOWING GAS TESTING CONNECTOR SERIES SEM-125-02-03.0-H-D-WT TEM-125-02-03.0-H-D-WT SAMTEC, INC. APPROVED BY: DOMINIC ARPINO PROGRAM MANAGER CONTECH RESEARCH,

More information

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-20258-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 2016-02-02 to 2021-02-01 Holder of certificate: Amphenol-Tuchel

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 QUALITY CONTROL SERVICES, INC. 2340 SE 11 th Avenue Portland, OR 97214 George Cahill Phone: 503 236 2712 CALIBRATION Valid To: September

More information

SmartSensor HD Performance Test Results

SmartSensor HD Performance Test Results Performance Test Results TEST REPORT In order to show compliance with specifications for bid submittal and verification purposes, several performance tests were conducted. The following sections contain

More information

MILITARY SPECIFICATION CORROSION PREVENTIVE COMPOUNDS, WATER DISPLACING, ULTRA-THIN FILM PAGE 1

MILITARY SPECIFICATION CORROSION PREVENTIVE COMPOUNDS, WATER DISPLACING, ULTRA-THIN FILM PAGE 1 NOT MEASUREMENT SENSITIVE 26 November 1997 SUPERSEDING AMENDMENT 2 31 July 1996 MILITARY SPECIFICATION CORROSION PREVENTIVE COMPOUNDS, WATER DISPLACING, ULTRA-THIN FILM This amendment forms a part of,

More information

CREEP PERFORMANCE TEST REPORT. Rendered to: TREX COMPANY LLC. Seclusions Composite Privacy Fence System TYPE: Composite Fence System

CREEP PERFORMANCE TEST REPORT. Rendered to: TREX COMPANY LLC. Seclusions Composite Privacy Fence System TYPE: Composite Fence System Architectural Testing CREEP PERFORMANCE TEST REPORT Rendered to: TREX COMPANY LLC Seclusions Composite Privacy Fence System TYPE: Composite Fence System Report No.: Report Date: Expiration Date: 130 Derry

More information

Salt Spray Test Chamber Model SSe CASS/AASS ASTM B 368 ISO 9227 JIZ 2371

Salt Spray Test Chamber Model SSe CASS/AASS ASTM B 368 ISO 9227 JIZ 2371 Salt Spray Test Chamber Model SSe CASS/AASS ASTM B 368 ISO 9227 JIZ 2371 Specification/Model SS600e CASS/AASS SS1000e CASS/AASS SS1300e CASS/AASS SS3000e CASS/AASS Chamber Temperature Range Ambient + 9

More information

THREE RANGE DS METERS Operation Instructions

THREE RANGE DS METERS Operation Instructions THREE RANGE DS METERS Operation Instructions User Manual for Models 532T1 532T2 532M1245-25 2450 Impala Drive Carlsbad, CA 92010-7226 USA Tel 760-438-2021 Fax 800-869-7668 / 760-931-9189 www.myronl.com

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 DEKRA IST RELIABILITY SEVICES INC. No. 22 Puding Rd., East Dist. Hsinchu City 300, Taiwan, R.O.C. Phone: 886 3 579 5766 ext 7100 Mr. General Lee general.lee@dekra-ist.com

More information

PRODUCT SPECIFICATION

PRODUCT SPECIFICATION ML-XT COMMERCIAL VEHICLE CONNECTOR SERIES 1.0 SCOPE This Product Specification relates to the ML-XT Commercial Vehicle, (CV), Power and/or Signal wire-to-wire connector system. This system consists of

More information

Aug07 Rev A All Paragraphs Revised

Aug07 Rev A All Paragraphs Revised Qualification Test Report Universal MATE-N-LOK* Connector 110-213 28Aug07 Rev A All Paragraphs Revised 1. INTRODUCTION 1.1. Purpose 1.2. Scope Testing was performed on Universal MATE-N-LOK* connectors

More information

Temperature Life with or without Electrical Load Test Procedure for Electrical Connectors and Sockets

Temperature Life with or without Electrical Load Test Procedure for Electrical Connectors and Sockets ANSI/EIA-364-17B-1999 Approved: April 23, 1999 EIA STANDARD EIA-364-17B TP-17B Temperature Life with or without Electrical Load Test Procedure for Electrical Connectors and Sockets EIA-364-17B (Revision

More information

Rated voltage: 100~277 VAC Frequency: 50/60Hz Wattage: 14 W

Rated voltage: 100~277 VAC Frequency: 50/60Hz Wattage: 14 W Customer Company & Address: MaxLite ADD: 12 York Ave, West Caldwell, NJ 07006 Contact Person: Francisco Garza Telephone: 973-244-7300x142 Telephone: fgarza@maxlite.com Manufacturer: Country of Origin:

More information

ACCELERATED CORROSION TEST CHAMBERS

ACCELERATED CORROSION TEST CHAMBERS ACCELERATED CORROSION TEST CHAMBERS SALT SPRAY CYCLIC ACCT CCT CASS IMMERSION TANK SATURATED HUMIDITY KESTERNICH-SO 2 UV PROHESION GRAVELOMETER www.equilamna.com SALT SPRAY Industries Served: : Paint,

More information

ADD: Room New Victory House, Wing Lok Street, Central, HONG KONG

ADD: Room New Victory House, Wing Lok Street, Central, HONG KONG Customer Company & Address: GREEN CREATIVE ADD: Room 1206-7 New Victory House, 93-103 Wing Lok Street, Central, HONG KONG Contact Person: Guillaume Vidal Telephone: +86 21-62320308 Email address: guillaume@gc-lighting.com

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 NORTHERN BALANCE AND SCALE, INC. 9556 W. Bloomington Freeway Bloomington, MN 55431 Joey Kaluser Phone: 952 881 7716 CALIBRATION Valid

More information

SHOCK TEST REPORT. Report No. : ENVA S9 Model Number : S9

SHOCK TEST REPORT. Report No. : ENVA S9 Model Number : S9 Report No. : ENVA10072605 S9 Model Number : S9 Page: 1 of 6 Product Name : S9 Model Number : S9 Date of Receipt : Jul. 26, 2010 Finished date of Test : Jul. 26, 2010 We, Spectrum Research & Testing Laboratory

More information

CONTINUOUS IMMERSION AND DUST TEST REPORT

CONTINUOUS IMMERSION AND DUST TEST REPORT Report No. :HS1404020081A Version:A CONTINUOUS IMMERSION AND DUST TEST REPORT Company Address :Taiway Electronics Components Co. :4F., No. 4, 6, 8, Lane 359, Sec. 2, Zhongshan Rd., Zhonghe Dist., New Taipei

More information

EMC and Durability Lab, HCL Technologies Ltd., #73-74, South Phase, Ambattur Industrial Estate, Chennai

EMC and Durability Lab, HCL Technologies Ltd., #73-74, South Phase, Ambattur Industrial Estate, Chennai Last Amended on - Page 1 of 10 I. EMI / EMC TESTS 1. IT Products / Household / Industrial / Medical / Network Telecommunications Equipment Radiated Emission Test (RE) CISPR11:2010 BSEN 55011:2010 CISPR22:2008

More information

Two-Stroke-Cycle Gasoline Engine Lubricant Evaluation D4857 (Y350M2) ASTM TC Sequence I Test Procedure Title / Validity Declaration Page Form 1

Two-Stroke-Cycle Gasoline Engine Lubricant Evaluation D4857 (Y350M2) ASTM TC Sequence I Test Procedure Title / Validity Declaration Page Form 1 Title / Validity Declaration Page Form 1 Version Conducted for I = Invalid V =Valid NR = Non-Reference Test Oil RO = Reference Oil Result EOT Time Reference Oil Formulation/Stand Alternate Codes Test Number

More information

Closed Cup Flash Point Tester

Closed Cup Flash Point Tester www.labtron.com info@labtron.com We have distinguished ranges of Closed Cup Flash Point Tester especially designed to offer highest level of accuracy and quality giving a versatility in the capacity and

More information

8,1,8,1,2,7,2,7,6,3,6,3,4,5,4,5

8,1,8,1,2,7,2,7,6,3,6,3,4,5,4,5 \ 8,1,8,1,2,7,2,7,6,3,6,3,4,5,4,5 Marine Salt Testa Digital meter for the measurement of salinity, specific gravity and temperature Operation Manual 1. PRECAUTION The Marine Salt testa is for the sole

More information

Cyclic Corrosion Chamber C.C.T AUTO Series

Cyclic Corrosion Chamber C.C.T AUTO Series Cyclic Corrosion Chamber C.C.T AUTO Series CCT 5000 AUTO image merely illustrative Cooling system image merely illustrative Specifications/ Models CCT 1300 AUTO CCT 3000 AUTO CCT 5000 AUTO Allows 7 different

More information

14 April 2016 Total Pages: 2. WET PENDULUM SLIP RESISTANCE Job No: M16/10016

14 April 2016 Total Pages: 2. WET PENDULUM SLIP RESISTANCE Job No: M16/10016 ATTAR TEST REPORT NUMBER: 16/10016.2 The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. Accredited for compliance with

More information

Test Report Current (Gen 2) Pendant Armor and Gen 3 Pendant Armor Polymer A Hanger and Polymer B Hanger March 16, 2016 (Q022516U1R2) Testing Location

Test Report Current (Gen 2) Pendant Armor and Gen 3 Pendant Armor Polymer A Hanger and Polymer B Hanger March 16, 2016 (Q022516U1R2) Testing Location Client Roboworld Molded Products, LLC 8216 Pricinceton-Glendale Road, Suite 246 West Chester, OH 45069 Test Report Current (Gen 2) Pendant Armor and Gen 3 Pendant Armor Polymer A Hanger and Polymer B Hanger

More information

SPECIFICATION AND PERFORMANCE TABLE OF CONTENT. 1. Scope Reference Documents Material and Components... 2

SPECIFICATION AND PERFORMANCE TABLE OF CONTENT. 1. Scope Reference Documents Material and Components... 2 TABLE OF CONTENT 1. Scope... 2 2. Reference Documents.. 2 3. Material and Components...... 2 4. Design and Construction..... 2 5. Rating.. 2 6. Performance and Test Descriptions. 2 7. Test Requirements

More information

GENERAL SPECIFICATION

GENERAL SPECIFICATION ALPHA 2001 MD TMA (Truck Mounted Attenuator GENERAL SPECIFICATION I. GENERAL A. All ALPHA 2001 MD Truck Mounted Attenuators (ALPHA 2001 MD TMA) shall be designed and manufactured by Energy Absorption systems,

More information

FEBRRUARY 22, 2008 TEST REPORT # QSH/QTH/QTE SERIES CONNECTOR SHEAR TESTING SAMTEC, INC.

FEBRRUARY 22, 2008 TEST REPORT # QSH/QTH/QTE SERIES CONNECTOR SHEAR TESTING SAMTEC, INC. FEBRRUARY 22, 2008 TEST REPORT #207908 QSH/QTH/QTE SERIES CONNECTOR SHEAR TESTING SAMTEC, INC. APPROVED BY: DOMINIC ARPINO PROGRAM MANAGER CONTECH RESEARCH, INC. Contech Research REVISION HISTORY DATE

More information

TÜV NEDERLAND P.O. Box AC Best - The Netherlands De Waal 21C PH Best - The Netherlands +31 (0) (0)

TÜV NEDERLAND P.O. Box AC Best - The Netherlands De Waal 21C PH Best - The Netherlands +31 (0) (0) TÜV NEDERLAND P.O. Box 120-5680 AC Best - The Netherlands De Waal 21C - 5684 PH Best - The Netherlands +31 (0)499-339500 - +31 (0)499-339539 Pendulum impact testing on double bar gate type DG-950 (UDG-37)

More information

D 5966 Roller Follower Wear Test. Final Report Cover Sheet. Report Packet Version No. Conducted For:

D 5966 Roller Follower Wear Test. Final Report Cover Sheet. Report Packet Version No. Conducted For: Final Report Cover Sheet Report Packet Version No. Conducted For: V = Valid I = Invalid Test Stand Stand Run Engine Engine Run A Alternate Codes Time Completed In my opinion this test been conducted in

More information

CLIMATE. Climate and temperature chambers.

CLIMATE. Climate and temperature chambers. Climate and temperature chambers. The Environmental Competence Centre has a number of climate chambers at its disposal to carry out low and high temperature tests, as well as a number of combined climate

More information

Bante220 Portable ph Meter Instruction Manual

Bante220 Portable ph Meter Instruction Manual Bante220 Portable ph Meter Instruction Manual BANTE INSTRUMENTS CO., LTD Bante220 Portable ph Meter 1 Introduction Thank you for selecting the Bante220 portable ph meter. This manual provides a step-by-step

More information

VIBRATION AND MECHANICAL SHOCK TEST REPORT

VIBRATION AND MECHANICAL SHOCK TEST REPORT Report No. :DH1701190024A-1 Version:A VIBRATION AND MECHANICAL SHOCK TEST REPORT Company :OTO Photonics Inc. Address :9F-5,No. 27, Guanxin Rd., East Dist., Hsinchu City 30072, Taiwan(R.O.C.) Sample Name

More information

ENVIRONMENTAL TESTING

ENVIRONMENTAL TESTING ENVIRONMENTAL TESTING Environmental Testing Foreword & Introduction Tests Heat - Cold - Climate Page 3 Thermal Shock Page 4 Low - High Pressure Page 4 Vibration Page 5 Mechanical Shock Page 6 Corrosive

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 LABORATORY SERVICES, PETROTRIN Southern Main Road Pointe-A-Pierre, Trinidad, Trinidad & Tobago Peter Bhim Phone: 868 658 4200 CHEMICAL Valid To: November 30,

More information

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For IESNA LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT For Room 316, Building 2, No.1, Xianke Yi Road, Huadong Town, Huadu District, Guangzhou, China Model:100B10C10(Ra2)

More information

OPERATORS MANUAL FOR USE WITH MAGNETIC/HEATED STIRRER MG200

OPERATORS MANUAL FOR USE WITH MAGNETIC/HEATED STIRRER MG200 OPERATORS MANUAL FOR USE WITH MAGNETIC/HEATED STIRRER MG200 ISSUE 4 April 2007 TABLE OF CONTENTS Page 1.0. GENERAL INFORMATION 2 1.1. DEFINITION 2 1.2. PRINCIPE OF OPERATION 2 2.0. TECHNICAL DESCRIPTION

More information

INDEPENDENT TEST LABORATORY REPORT No A

INDEPENDENT TEST LABORATORY REPORT No A Lighting Sciences, Inc. UL Verification Services 7826 E. Evans Rd. Scottsdale, Arizona 85260 USA P: 480-991-9260 F: 480-991-0375 lsi@ul.com www.lightingsciences.com Description: The sample(s) was(were)

More information

ALPHA 70K TMA (Truck Mounted Attenuator) GENERAL SPECIFICATIONS

ALPHA 70K TMA (Truck Mounted Attenuator) GENERAL SPECIFICATIONS ALPHA 70K TMA (Truck Mounted Attenuator) GENERAL SPECIFICATIONS I. GENERAL A. All ALPHA 70K Truck Mounted Attenuators (ALPHA 70K TMA) shall be designed and manufactured by Energy Absorption Systems, Incorporated,

More information

High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph

High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph Application Note Petrochemicas High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph Author James D. McCurry, Ph.D. Agilent Technologies, Inc. Abstract An Agilent

More information

ACCURACY RELIABILITY SIMPLICITY

ACCURACY RELIABILITY SIMPLICITY PoolMeter Model 512T5D Operation Manual 05 July 09 ACCURACY RELIABILITY SIMPLICITY Water Quality Instrumentation Accuracy Reliability Simplicity DESCRIPTION This manual describes your Myron L 512T5D Dual

More information

Physical Properties of Window Films

Physical Properties of Window Films Physical Properties of Window Films Name 3M Renewable Energy Date: July 3, 20104 Attn: Paul Neumann Revision Date: September 18, 2014 Address: 3M Center, 235-3D-02 Author: William Stegeman City, State,

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 & ANSI/NCSL Z540-1-1994 EUSTIS CO., INC./PYROCOM CALIBRATION LAB 12407-B Mukilteo Speedway Lynnwood, WA 98087 Bill LeMesurier Phone: 425 423 9996 CALIBRATION

More information

THERMOELECTRIC SAMPLE CONDITIONER SYSTEM (TESC)

THERMOELECTRIC SAMPLE CONDITIONER SYSTEM (TESC) THERMOELECTRIC SAMPLE CONDITIONER SYSTEM (TESC) FULLY AUTOMATED ASTM D2983 CONDITIONING AND TESTING ON THE CANNON TESC SYSTEM WHITE PAPER A critical performance parameter for transmission, gear, and hydraulic

More information

Lightweight Shock and Type I Vibration Test Report on UPS Model No. PS3200RM for Powerstar Inc. Gaithersburg, MD

Lightweight Shock and Type I Vibration Test Report on UPS Model No. PS3200RM for Powerstar Inc. Gaithersburg, MD Test Report No. 12069.1 No. of Pages 21 Lightweight Shock and Type I Vibration Test Report on UPS Model No. PS3200RM for Powerstar Inc. Gaithersburg, MD NU LABORATORIES 312 Old Allerton Road, Annandale,

More information

REPORT NO. TR-P NC SAFETY COMPLIANCE TESTING FOR FMVSS 223 REAR IMPACT GUARDS 2007 TRANSFREIGHT TECHNOLOGY NHTSA NO.

REPORT NO. TR-P NC SAFETY COMPLIANCE TESTING FOR FMVSS 223 REAR IMPACT GUARDS 2007 TRANSFREIGHT TECHNOLOGY NHTSA NO. REPORT NO. SAFETY COMPLIANCE TESTING FOR FMVSS 223 REAR IMPACT GUARDS 2007 TRANSFREIGHT TECHNOLOGY NHTSA NO. RIG 009 PREPARED BY: KARCO ENGINEERING, LLC. 9270 HOLLY ROAD ADELANTO, CALIFORNIA 92301 SEPTEMBER

More information

Report of Inspection

Report of Inspection P. O. Box 8238 Searcy, AR 72145 866.811.5237 / 501.279.1166 Fax: 501.279.1225 As required by NFPA 1911 19.3: CFS Inspections is accredited to the requirements of ISO/IEC 17020. Report of Inspection SAFET

More information

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For IESNA LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT For Guangzhou Hongli Opto-Electronic Co., Ltd. No.1, Xianke Yi Road, Huadong Town, Huadu District, Guangzhou,

More information

BERKELEY ANALYTICAL 815 Harbour Way South, Suite 6 Richmond, CA Ph ; Fax

BERKELEY ANALYTICAL 815 Harbour Way South, Suite 6 Richmond, CA Ph ; Fax BERKELEY ANALYTICAL 815 Harbour Way South, Suite 6 Richmond, CA 94804-3614 Ph. 510-236-2325; Fax 510-236-2335 E-mail info@berkeleyanalytical.com Product Sample Formaldehyde Emissions Customer & Building

More information

An Automated System for the Acoustical and Aerodynamic Characterization of Small Air Moving Devices

An Automated System for the Acoustical and Aerodynamic Characterization of Small Air Moving Devices Minneapolis, Minnesota NOISE-CON 2005 2005 October 17-19 An Automated System for the Acoustical and Aerodynamic Characterization of Small Air Moving Devices Jeff G. Schmitt David A. Nelson John Phillips

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 INDEPENDENT ENGINEERING LABORATORIES, INC. 1 2400 E. South Street Jackson, MI 49201 Ms. Jessica Stremich Phone: 517 788 6590 E-mail: IELaccounting@ielinc.com

More information

Sequence VH Report Forms Version Conducted For

Sequence VH Report Forms Version Conducted For Report Forms Version Conducted For V = Valid I = Invalid N = Results cannot be interpreted as representative of oil performance (Non-Reference Oil) and shall not be used in determining an average test

More information

SGS TEST REPORT. Page: 1 of 6 Date: April 20, itech Company LLC Christy Street, Fremont CA USA

SGS TEST REPORT. Page: 1 of 6 Date: April 20, itech Company LLC Christy Street, Fremont CA USA Page: 1 of 6 Date: April 20, 2010 itech Company LLC 41758 Christy Street, Fremont CA 94538 USA The following merchandise was submitted and identified by the vendor as: Product Description: 20.1 Multimedia

More information

Laboratory Report. U. S. Department of Justice

Laboratory Report. U. S. Department of Justice U. S. Department of Justice Laboratory Report To: SA CFI Richard Chandler Detroit Field Division 432 N. Saginaw Street Suite 605 Flint, Michigan 48502 Date of Report: Lab Number: 10F0052-1 Reference: 774040110026

More information

Flow Research and Test Center

Flow Research and Test Center SALES BULLETIN Flow Research and Test Center CREATING RESOURCE TECHNOLOGY FOR TODAY AND TOMORROW The key to FMC Technologies success has been its ability to provide the latest technology in products and

More information

SGO Series. SHEL LAB Gravity Convection Laboratory Ovens SGO1 SGO3 SGO5

SGO Series. SHEL LAB Gravity Convection Laboratory Ovens SGO1 SGO3 SGO5 SGO Series SHEL LAB Gravity Convection Laboratory Ovens SGO1 SGO3 Ideal for Industrial, Analytical, and General Laboratory Applications SHEL LAB Gravity Convention Laboratory Ovens are recommended for

More information

DUCOM HIGH FREQUENCY RECIPROCATING RIG

DUCOM HIGH FREQUENCY RECIPROCATING RIG DUCOM HIGH FREQUENCY RECIPROCATING RIG Product information sheet Asia 477/A, 4 th Phase, Peenya industrial area,bangalore-560 058,India Phone: +91-80-4080-5555 Fax: +91-80-4080-5510 America 620, Johnson

More information

Certificate of Accreditation

Certificate of Accreditation Certificate of Accreditation ISO/IEC 17025:2005 Certificate Number L2264.03 Analysts, Inc. 2450 Hassell Road Hoffman Estates IL 60195 has met the requirements set forth in L-A-B s policies and procedures,

More information

WET PENDULUM SLIP RESISTANCE Job No: M14/7986

WET PENDULUM SLIP RESISTANCE Job No: M14/7986 ATTAR TEST REPORT NUMBER: 14/7986 The results of the tests, calibrations and/or measurements included in this document are traceable to Australian/national standards. Accredited for compliance with ISO/IEC

More information

NATIONAL TECHNICAL SYSTEMS

NATIONAL TECHNICAL SYSTEMS Test Report Number 41418-09.PPC Testing of Pancake Alternator & PMU PREPARED FOR: The Perfect Parts Company Sullivan Products 1 North Haven Street Baltimore, MD 21224 PREPARED BY: National Technical Systems

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ELITE ELECTRONIC ENGINEERING, INC. 1 1516 Centre Circle Downers Grove, IL 60515 Larry Brooks (QA Manager) Phone: 630 495 9770 ext. 166 Email: lbrooks@elitetest.com

More information

PH20 Value ph Tester Instruction Manual

PH20 Value ph Tester Instruction Manual PH20 Value ph Tester Instruction Manual APERA INSTRUMENTS, LLC www.aperainst.com v 3.3 1 1. Battery Installation Please install batteries according to the following steps. *Please note the correct direction

More information

1P D 6681 Final Report Cover Sheet

1P D 6681 Final Report Cover Sheet D 6681 Final Report Cover Sheet Method Version Conducted For V = Valid I = Invalid N = Results Cannot be Interpreted as Representative of Oil Performance (Non- Reference Oil) and Shall Not be Used in Determining

More information

SM1206 Series. Overload Interrupt Time (Second) Nominal Rating - Note 2. Cold Resistance (Ohm) Note 1. Maximum I 2 T (Ampere 2 Second) Nominal Rating

SM1206 Series. Overload Interrupt Time (Second) Nominal Rating - Note 2. Cold Resistance (Ohm) Note 1. Maximum I 2 T (Ampere 2 Second) Nominal Rating SM1206 Series Part Numbering System SM1206-32 - 1.0 Fuse Type Voltage Amp Part Number/Rating Cold Resistance (Ohm) Note 1 Overload Interrupt Time (Second) Nominal Rating - Note 2 Maximum I 2 T (Ampere

More information

Qualification of a precision pattern dispenser

Qualification of a precision pattern dispenser Qualification of a precision pattern dispenser Raf Van Ammel, Katarzyna Sobiech-Matura, Uwe Wätjen 2016 EUR 28268 EN This publication is a Technical report by the Joint Research Centre, the European Commission

More information

Compliance Test Results. of Independently Manufactured. Automotive Replacement Headlamps. to FMVSS 108. Study I. March 18, 2003

Compliance Test Results. of Independently Manufactured. Automotive Replacement Headlamps. to FMVSS 108. Study I. March 18, 2003 Compliance Test Results of Independently Manufactured Automotive Replacement Headlamps to FMVSS 108 Study I March 18, 2003 Prepared By Certified Automotive Parts Association 1518 K Street NW, Suite 306

More information

Test Report. for. Chilicon Power 1563 Calle Patricia Pacific Palisades, CA USA. Project Number: G Prepared By:

Test Report. for. Chilicon Power 1563 Calle Patricia Pacific Palisades, CA USA. Project Number: G Prepared By: Test Report for Chilicon Power 1563 Calle Patricia Pacific Palisades, CA 90272 USA Project Number: G100834560 Prepared By: Intertek 1500 Brigantine Drive Coquitlam, B.C. V3K 7C1 Canada Intertek Testing

More information

1 st Quarter Summary of Meteorological and Ambient Air Quality Data Kennecott Utah Copper Monitoring Stations. Prepared for:

1 st Quarter Summary of Meteorological and Ambient Air Quality Data Kennecott Utah Copper Monitoring Stations. Prepared for: 1 st Quarter 2018 Summary of Meteorological and Ambient Air Quality Data Kennecott Utah Copper Monitoring Stations Prepared for: Prepared by: Mr. Bryce C. Bird Director Division of Air Quality 195 North

More information

mga research corporation

mga research corporation mga research corporation UNDERGROUND TECHNOLOGIES MAN-HOLE CONSTRUCTION VERTICAL STATIC LOAD TEST SERIES (PO# 11521) 446 executive drive troy, mi 48083 248 / 577-5001 fax 248 / 577-5025 www.mgaresearch.com

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 METTLER TOLEDO (INDUSTRIAL) 1900 Polaris Parkway Columbus, OH 43240 Frank Gardone Phone: 412 213 2263 CALIBRATION Valid To: April 30,

More information

Schedule. 200 C to 400 C. 400 C to 660 C C to 800 C C to 1300 C C to 1200 C. 0 C to 1700 C. 0 C to 1700 C.

Schedule. 200 C to 400 C. 400 C to 660 C C to 800 C C to 1300 C C to 1200 C. 0 C to 1700 C. 0 C to 1700 C. Page: 1 of 9 LABORATORY LOCATION: (PERMANENT LABORATORY) PPCALIBRATION SERVICES SDN. BHD. NO. 15, MEDAN BUKIT EMAS PUSAT PERNIAGAAN BUKIT EMAS 14000 BUKIT MERTAJAM, PULAU PINANG MALAYSIA This laboratory

More information

TMS CABLE MARKERS CM-SCE & CM-SCE-TP. Tie on Identification Product

TMS CABLE MARKERS CM-SCE & CM-SCE-TP. Tie on Identification Product Page 1 of 12 October 2015 Specification RW-2513 Document Number: 108-121016 TMS CABLE MARKERS CM-SCE & CM-SCE-TP Including HL cable marker range Tie on Identification Product SCOPE This quality assurance

More information

Safe-Stop TMA (Truck Mounted Attenuator) GENERAL SPECIFICATIONS

Safe-Stop TMA (Truck Mounted Attenuator) GENERAL SPECIFICATIONS Safe-Stop TMA (Truck Mounted Attenuator) GENERAL SPECIFICATIONS I. GENERAL A. All Safe-Stop Truck Mounted Attenuators (Safe-Stop TMA) shall be designed and manufactured by Energy Absorption Systems, Incorporated,

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL13048-001A CR4T-790L-27K-12-E26GU24 Date: 08/22/18 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Tammy Lehrmann

More information

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report

Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Report Number: Model: PL09173-004B IG-NM-5S-A-30K-UL-WH xxx Date: 09/21/2016 Cree Racine Engineering Services Testing Laboratory (RESTL) Photometric Testing and Evaluation Report Prepared For: Zongjie

More information

BQ-9000 Quality Management System. Accredited Producer Requirements

BQ-9000 Quality Management System. Accredited Producer Requirements BQ-9000 Quality Management System Accredited Producer Requirements Revision 4 Effective Date: February 1, 2007 This requirements document has been prepared by the National Biodiesel Accreditation Commission,

More information

AIIPA Standardized Best Practices Recommendations

AIIPA Standardized Best Practices Recommendations AIIPA Standardized Best Practices Recommendations AIIPA recognizes that BAIIDS programs differ from state or jurisdictions for a variety of reasons. Differences will be found in regard to legal issues

More information

PROVIDING ACCURATE DATA IN A TIMELY MANNER

PROVIDING ACCURATE DATA IN A TIMELY MANNER PROVIDING ACCURATE DATA IN A TIMELY MANNER 248 Hughes Lane St. Charles MO 63301 Ph. (636) 949-5835 Fax (636) 723-5835 www.elteklabs.com MATERIAL PROPERTIES LAB TRACKING TESTS TEST METHOD UL 746-A Section

More information