1 Environmental Test Report Date: March 14, 2018 Report Number: R5597 Orbital ATK Alliant Techsystems Operations LLC 4700 Nathan Lane Plymouth, MN United States 3/14/2018 Prepared By: Jessica Tonz Date Element Portland Quality Administrator 3/14/2018 Reviewed By: Frederick Tognoli Date Element Portland Technical Writer 3/16/2018 Concurred By: Kendall Jones Date Element Seattle Lab Manager The data herein represents only the item(s) tested. This report shall not be reproduced, except in full, without prior permission of Element Materials Technology. EAR Controlled Data: This document contains technical data whose export and re-export/retransfer is subject to control by the U.S. Department of Commerce under the Export Administration Act and the Export Administration Regulations. The Department of Commerce's prior written approval is required for the export or re-export/retransfer of such technical data to any foreign person, foreign entity or foreign organization whether in the United States or abroad This project shall be governed exclusively by the General Terms and Conditions of Sale and Performance of Testing Services by Element Materials Technology. In no event shall be liable for any consequential, special or indirect loss or any damages above the cost of the work. Page 1 of 45

2 TABLE OF CONTENTS ADMINISTRATIVE DATA 3 REVISIONS INTRODUCTION SCOPE PURPOSE TEST SEQUENCE APPLICABLE DOCUMENTS SPECIFICATION GENERAL INFORMATION TEST EQUIPMENT TEST CONDITIONS TEST WITNESSING/MONITORING TEST RECORDING SALT FOG PROCEDURES TENSILE PROCEDURES AIRTIGHTNESS PROCEDURES 11 APPENDIX A TEST PHOTOGRAPHS 12 SALT FOG RUN 1 (CANS) 12 SALT FOG RUN 2 (LIDS) 24 TENSILE 29 AIRTIGHTNESS 39 APPENDIX B TEST PLOTS, CHARTS, GRAPHS 44 Report Number: R5597 March 14, 2018 Page 2 of 45

3 ADMINISTRATIVE DATA Prepared For: Henry Turnbill Orbital ATK 4700 Nathan Lane Plymouth, MN United States Tests Performed: Environmental testing per Table 1 on page 5 Test Facility: Test Unit Descriptions: Part Number(s): Serial Number(s): Primary Test Specification(s): Purchase Order Number(s): Element Job Number: Element Quote Number(s): Six (6) Ammo cans and two (2) ammo can lids Six (6) PA125 cans and two (2) PA125 lids A1, A2, SF1, SF2, SFL1, SFL2, T1, and T2 MIL-C MP P EPO005597Q Project Begin Date: 2/23/2018 Project Completion Date: 3/9/2018 Test Report Completion Date: March 14, 2018 Report Number: R5597 March 14, 2018 Page 3 of 45

4 REVISIONS Revision Description Date Approval N/A Original Release March 16, 2018 KJ Report Number: R5597 March 14, 2018 Page 4 of 45

5 1.0 INTRODUCTION 1.1 Scope This document describes procedures and performance of the Environmental Tests performed in accordance with specification: MIL-C The results described in this report relate only to the specific items tested. 1.2 Purpose The purpose of this test was to demonstrate that the test specimens met or exceeded the design specification requirements during or upon completion of exposure to the stresses detailed herein. 1.3 Test Sequence The following tests were conducted during the course of Environmental Testing: Table 1 Environmental Test Sequence Test Start Date End Date Salt Fog 2/23/2018 3/9/2018 Tensile 2/28/2018 2/28/2018 Airtightness 2/28/2018 2/28/2018 Report Number: R5597 March 14, 2018 Page 5 of 45

6 2.0 APPLICABLE DOCUMENTS 2.1 Specification MIL-C-70842, dated 15 August GENERAL INFORMATION 3.1 Test Equipment All test instrumentation was calibrated in accordance with ANSI/NCSL Z540.3 or ISO 10012, as applicable, and is traceable to a recognized National Metrology Institute (NMI). The following tables list the equipment used during the testing: Table 2 Salt Fog Equipment Test Dates: 2/23/2018 to 3/9/2018 ID# Description Mfg. Model# Last Cal Next Cal EC709 Salt Fog Chamber Harshaw Unknown 7/31/17 7/31/ Hydrometer VWR /2/16 6/2/ Scale Balance Yamato PPC-200W 5/11/17 5/11/ ph Meter Oakton ph 5 4/10/17 Cal Before Use Graduated Cylinder unknown (10 to 100) ml 3/17/16 ICO S ph 10 Buffer Cole Palmer Expires 7/1/18 S ph7 Buffer Cole Palmer Expires 7/1/18 S ph4 Buffer Cole Palmer Expires 12/1/18 Table 3 Tensile Equipment Test Dates: 2/28/2018 to 2/28/2018 ID# Description Mfg. Model# Last Cal Next Cal Stop Watch Control Company Unknown 5/25/17 5/25/ Load Cell MTS C-01 6/28/17 6/28/ Load Cell Display Futek IPM 500 6/28/17 6/28/18 H1721 Tensile Test Machine Instron 4505 Reference Only Table 4 Airtightness Equipment Test Dates: 2/28/2018 to 2/28/2018 ID# Description Mfg. Model# Last Cal Next Cal Stop Watch Control Company /25/17 5/25/ Digital Pressure Gauge Heise N40/40KPA 4/25/17 4/25/18 Report Number: R5597 March 14, 2018 Page 6 of 45

7 3.0 GENERAL INFORMATION (continued) 3.2 Test Conditions Unless specified herein, all tests and measurements were performed at the room ambient conditions existing at the laboratory during testing: Temperature: 10 C to 40 C Relative Humidity: Ambient to 90% 3.3 Test Witnessing/Monitoring All testing was conducted by a qualified Element Portland Environmental Test Technician under the direction and cognizance of the Lab Manager and Quality Assurance. 3.4 Test Recording Chronological logs of all significant events are maintained by test lab personnel and indicate date, times and descriptions of conditions. These logs are used as reference, retained at Element and available upon request. Test setup photographs are provided in Appendix A, with any additional charts, plots, or graphs provided in Appendix B. Report Number: R5597 March 14, 2018 Page 7 of 45

8 4.0 Salt Fog Procedures 4.1 Setup Two (2) ammo cans, serial numbers SF1 and SF2, were visually inspected with no signs of damage or any other anomalies noted Note: For Run 1, the body of the ammo cans were the actual test articles, the lids were not being tested The test units were scribed with a line on each side Test units SF1 and SF2 were installed in the salt fog chamber at a 15 degree angle from horizontal. 4.2 Run 1 Steps (Ammo Cans) Began 80 hours of exposure to a 5% salt fog solution, at +35 C, with a ph from 6.5 to Salt fog fallout was collected approximately hours after start of testing specific gravity (SG), 6.77pH No fallout rate was collected due to the tubes overfilling over the weekend Completed 80 hours of salt of exposure, the test units were removed from the chamber and fallout was collected mL: 2.13 ml/80cm2/hr, 1.031SG, 6.65pH Test units were rinsed and the scribe marks were scraped and evaluated No corrosion extended past the scribe marks No blistering or flaking was visible on the ammo can sides (SF1 and SF2) The lids had paint flaked off, but there was no corrosion past the scribe noted The customer was notified and replacement lids were sent for testing Upon test completion, at ambient conditions, the units were visually inspected, then returned to customer for final analysis. Report Number: R5597 March 14, 2018 Page 8 of 45

9 4.3 Run 2 Steps (Lids) Two (2) ammo can lids, serial numbers SFL1 and SFL2, were visually inspected with no signs of damage or any other anomalies noted Note: For Run 2, only ammo can lids were tested Test units SFL1 and SFL2 were installed in the salt fog chamber at a 15 degree angle from horizontal Began 80 hours of exposure to a 5% salt fog solution, at +35 C, with a ph from 6.5 to Salt fog fallout was collected approximately 24 and 48 hours after start of testing hours: 97mL: 2.02mL/80cm2/hr, 1.030SG, 6.56pH hours: 110mL: 2.29mL/80cm2/hr, 1.031SG, 6.59pH Completed 80 hours of salt of exposure, the test units were removed from the chamber and fallout was collected mL: 2.16mL/80cm2/hr, 1.031SG, 6.54pH Test units were rinsed and the scribe marks were scraped and evaluated SFL2 had minor paint flaking at scribe point Under 1/8 of an inch; unit met requirements Upon test completion, at ambient conditions, the units were visually inspected, then returned to customer for final analysis. 4.4 Results Test units SF1, SF2, and SFL1 had no corrosion beyond the scribe marks and no blistering or flaking noted Test unit SFL2 had minor paint flaking at the scribe location Under 1/8 of an inch; unit met requirements Test photographs provided in Appendix A Applicable graphs, charts, and/or plots provided in Appendix B. Report Number: R5597 March 14, 2018 Page 9 of 45

10 5.0 Tensile Procedures 5.1 Setup Two (2) ammo cans, serial numbers T1 and T2, were visually inspected with no signs of damage or any other anomalies noted. 5.2 Steps Test unit T1 was setup on the test machine Applied a 600lb load for one minute on test unit T1 s latch assembly No bending or distortion observed Test unit T2 was setup on the test machine Applied a 600lb load for one minute on test unit T2 s latch assembly No bending or distortion observed Test unit T1 was setup on the test machine Applied a 600lb load for one minute on test unit T1 s wire handle assembly No bending or distortion observed Test unit T2 was setup on the test machine Applied a 600lb load for one minute on test unit T2 s wire handle assembly No bending or distortion observed Test unit T1 was setup on the test machine Applied a 1200lb load for one minute on test unit T1 s hasp assembly Slight deformation of the box and hasp assembly. No broken welds or detached components observed Test unit T2 was setup on the test machine Applied a 600lb load for one minute on test unit T2 s hasp assembly Slight deformation of the box and hasp assembly. No broken welds or detached components observed Upon test completion, at ambient conditions, the test units were visually inspected, then returned to customer for final analysis. 5.3 Results No bending or distortion observed on T1 s or T2 s latch assembly at 600lbs No bending or distortion observed on T1 s or T2 s wire handle assembly at 600lbs Slight deformation observed on both T1 s and T2 box and hasp assembly at 1200lbs No broken welds or detached components observed Test photographs provided in Appendix A. Report Number: R5597 March 14, 2018 Page 10 of 45

11 6.0 Airtightness Procedures 6.1 Setup Two (2) ammo cans, serial numbers A1 and A2, were visually inspected with no signs of damage or any other anomalies noted A pressure port was installed on the bottoms of the cans. 6.2 Steps The test units were inverted and placed in a dunk tank full of room temperature water The lids and gaskets were completely submerged Applied internal pressure of 3psi for a minimum of 30 seconds Upon test completion, at ambient conditions, the test units were visually inspected, then returned to customer for final analysis. 6.3 Results No signs of damage or bubbles observed from either test unit Test photographs provided in Appendix A. Report Number: R5597 March 14, 2018 Page 11 of 45

12 APPENDIX A TEST PHOTOGRAPHS Salt Fog Run 1 (Cans) Photo 1 Pre-test, sides 1 and 2 Photo 2 Pre-test, sides 2 and 3 Report Number: R5597 March 14, 2018 Page 12 of 45

13 Photo 3 Pre-test, sides 3 and 4 Photo 4 Pre-test, sides 1 and 4 Report Number: R5597 March 14, 2018 Page 13 of 45

14 Photo 5 Pre-test, sides 5 and 3 Photo 6 Pre-test, sides 6 and 3 Report Number: R5597 March 14, 2018 Page 14 of 45

15 Photo 7 Test units setup at approximately 15 degree angle from horizontal Photo 8 Test units setup in chamber Report Number: R5597 March 14, 2018 Page 15 of 45

16 Photo 9 Post-test units in chamber Photo 10 Post-test sides 1 and 2 Report Number: R5597 March 14, 2018 Page 16 of 45

17 Photo 11 Post-test sides 2 and 3 Photo 12 Post-test sides 3 and 4 Report Number: R5597 March 14, 2018 Page 17 of 45

18 Photo 13 Post-test sides 3 and 4 Photo 14 Post-test sides 6 and 3 Report Number: R5597 March 14, 2018 Page 18 of 45

19 Photo 15 Post-test sides 5 and 3 Photo 16 Post-test close up Report Number: R5597 March 14, 2018 Page 19 of 45

20 Photo 17 Post-test close up Photo 18 Post-test close up Report Number: R5597 March 14, 2018 Page 20 of 45

21 Photo 19 Post-test close up Photo 20 Post-test close up Report Number: R5597 March 14, 2018 Page 21 of 45

22 Photo 21 Post-test close up Photo 22 Post-test close up Report Number: R5597 March 14, 2018 Page 22 of 45

23 Photo 23 Post-test close up Report Number: R5597 March 14, 2018 Page 23 of 45

24 Salt Fog Run 2 (Lids) Photo 24 Pre-test Photo 25 Test units setup at approximately 15 degree angle from horizontal Report Number: R5597 March 14, 2018 Page 24 of 45

25 Photo 26 Test units setup in chamber Photo 27 Post-test units in chamber Report Number: R5597 March 14, 2018 Page 25 of 45

26 Photo 28 Post-test Photo 29 Post-test Report Number: R5597 March 14, 2018 Page 26 of 45

27 Photo 30 Post-test Photo 31 Post-test Report Number: R5597 March 14, 2018 Page 27 of 45

28 Photo 32 Post-test Report Number: R5597 March 14, 2018 Page 28 of 45

29 Tensile Photo 33 Pre-test, unit T1 Photo 34 Pre-test, unit T1 Report Number: R5597 March 14, 2018 Page 29 of 45

30 Photo 35 Pre-test, unit T1 Photo 36 Pre-test, unit T1 Report Number: R5597 March 14, 2018 Page 30 of 45

31 Photo 37 Pre-test, unit T1 Photo 38 Pre-test, unit T1 Report Number: R5597 March 14, 2018 Page 31 of 45

32 Photo 39 Pre-test, unit T2 Photo 40 Pre-test, unit T2 Report Number: R5597 March 14, 2018 Page 32 of 45

33 Photo 41 Pre-test, unit T2 Photo 42 Pre-test, unit T2 Report Number: R5597 March 14, 2018 Page 33 of 45

34 Photo 43 Pre-test, unit T2 Photo 44 Pre-test, unit T2 Report Number: R5597 March 14, 2018 Page 34 of 45

35 Photo 45 Test unit T1, latch testing Photo 46 Test unit T1, latch testing close up Report Number: R5597 March 14, 2018 Page 35 of 45

36 Photo 47 Test unit T2, latch testing Photo 48 Test unit T1, wire handle testing Report Number: R5597 March 14, 2018 Page 36 of 45

37 Photo 49 Test unit T2, wire handle testing Photo 50 Test unit T1, hasp testing Report Number: R5597 March 14, 2018 Page 37 of 45

38 Photo 51 Test unit T2, hasp testing Report Number: R5597 March 14, 2018 Page 38 of 45

39 Airtightness Photo 52 Pre-test Photo 53 Pre-test Report Number: R5597 March 14, 2018 Page 39 of 45

40 Photo 54 Pre-test Photo 55 Pre-test Report Number: R5597 March 14, 2018 Page 40 of 45

41 Photo 56 Pre-test Photo 57 Example of testing in progress Report Number: R5597 March 14, 2018 Page 41 of 45

42 Photo 58 Example of testing in progress Photo 59 Example of testing in progress Report Number: R5597 March 14, 2018 Page 42 of 45

43 Photo 60 Example of testing in progress Report Number: R5597 March 14, 2018 Page 43 of 45

44 APPENDIX B TEST PLOTS, CHARTS, GRAPHS Figure 1 Salt Fog Run 1 Temperature Chart Report Number: R5597 March 14, 2018 Page 44 of 45

45 APPENDIX B (continued) Figure 2 Salt Fog Run 2 Temperature Chart End of Report. Report Number: R5597 March 14, 2018 Page 45 of 45

SmartSensor 105 & Advance NEMA Salt Fog

SmartSensor 105 & Advance NEMA Salt Fog SmartSensor 105 & Advance NEMA Salt Fog Test Report Wavetronix products mentioned: SmartSensor 105 SmartSensor Advance As contracted by Wavetronix, Environ Laboratories LLC performed a NEMA salt fog test

More information

Physical Properties of Window Films

Physical Properties of Window Films Physical Properties of Window Films Name 3M Renewable Energy Date: July 3, 20104 Attn: Paul Neumann Revision Date: September 18, 2014 Address: 3M Center, 235-3D-02 Author: William Stegeman City, State,

More information

600 Amp Surge Arrester

600 Amp Surge Arrester R&D Center 497 Schooley s Mountain Road Hackettstown, NJ 07840-3906 Tele: 908-852-1122 Fax: 908-813-2091 TEST REPORT NUMBER: 379-17-12164 DATE: 4-3-2012 REPORT OF TEST ON 600 Amp Surge Arrester Statements

More information

CREEP PERFORMANCE TEST REPORT. Rendered to: TREX COMPANY LLC. Seclusions Composite Privacy Fence System TYPE: Composite Fence System

CREEP PERFORMANCE TEST REPORT. Rendered to: TREX COMPANY LLC. Seclusions Composite Privacy Fence System TYPE: Composite Fence System Architectural Testing CREEP PERFORMANCE TEST REPORT Rendered to: TREX COMPANY LLC Seclusions Composite Privacy Fence System TYPE: Composite Fence System Report No.: Report Date: Expiration Date: 130 Derry

More information

ENGINEERING AND TEST DIVISION CHURCH STREET, BOHEMIA, LONG ISLAND, NEW YORK (631)

ENGINEERING AND TEST DIVISION CHURCH STREET, BOHEMIA, LONG ISLAND, NEW YORK (631) DAYTON T. BROWNINC. Founded 1950 ENGINEERING AND TEST DIVISION CHURCH STREET, BOHEMIA, LONG ISLAND, NEW YORK 11716 (631) 589-6300 TEST REPORT NO: DBT04R99-1234 DAYTON T. BROWN, INC. JOB NO. 409817-00-000

More information

2.0 TEST PROCEDURES AND RESULTS Vibration Test TEST EQUIPMENT AND INSTRUMENTATION QUALITY ASSURANCE PROGRAM 7 ATTACHMENTS

2.0 TEST PROCEDURES AND RESULTS Vibration Test TEST EQUIPMENT AND INSTRUMENTATION QUALITY ASSURANCE PROGRAM 7 ATTACHMENTS Page No. 2 TABLE OF CONTENTS Page No. 1.0 INTRODUCTION 3 1.1 Scope 3 1.2 References 3 1.3 Test Specimen Description 3 1.4 Summary 3 2.0 TEST PROCEDURES AND RESULTS 4 2.1 Vibration Test 4 3.0 TEST EQUIPMENT

More information

AUGUST 28, 2008 TEST REPORT # REV.1.1 MIXED FLOWING GAS TESTING CONNECTOR SERIES CLP S-D-A FTSH S-DV-A SAMTEC, INC.

AUGUST 28, 2008 TEST REPORT # REV.1.1 MIXED FLOWING GAS TESTING CONNECTOR SERIES CLP S-D-A FTSH S-DV-A SAMTEC, INC. AUGUST 28, 2008 TEST REPORT #208383-3 REV.1.1 MIXED FLOWING GAS TESTING CONNECTOR SERIES CLP-130-02-S-D-A FTSH-130-02-S-DV-A SAMTEC, INC. APPROVED BY: DOMINIC ARPINO PROGRAM MANAGER CONTECH RESEARCH, INC.

More information

AUGUST 28, 2008 TEST REPORT # REV.1.1 MIXED FLOWING GAS TESTING CONNECTOR SERIES SEM H-D-WT TEM H-D-WT SAMTEC, INC.

AUGUST 28, 2008 TEST REPORT # REV.1.1 MIXED FLOWING GAS TESTING CONNECTOR SERIES SEM H-D-WT TEM H-D-WT SAMTEC, INC. AUGUST 28, 2008 TEST REPORT #208383-5 REV.1.1 MIXED FLOWING GAS TESTING CONNECTOR SERIES SEM-125-02-03.0-H-D-WT TEM-125-02-03.0-H-D-WT SAMTEC, INC. APPROVED BY: DOMINIC ARPINO PROGRAM MANAGER CONTECH RESEARCH,

More information

Note to users: This electronic document is not subject to copyright. You may copy it, but you are requested not to disseminate altered copies.

Note to users: This electronic document is not subject to copyright. You may copy it, but you are requested not to disseminate altered copies. Note to users: This electronic document is not subject to copyright. You may copy it, but you are requested not to disseminate altered copies. Technology Assessment Program NIJ Standard for Metallic Handcuffs

More information

Model 407SE Swivel Drawbar Eye

Model 407SE Swivel Drawbar Eye MANUFACTURING CO. THE FIRST NAME IN QUALITY COUPLINGS Installation, Inspection, Operation & Maintenance Guide Model 407SE Swivel Drawbar Eye IMPORTANT Read these instructions completely before installing,

More information

REPORT NO. TR-P NC SAFETY COMPLIANCE TESTING FOR FMVSS 223 REAR IMPACT GUARDS 2007 TRANSFREIGHT TECHNOLOGY NHTSA NO.

REPORT NO. TR-P NC SAFETY COMPLIANCE TESTING FOR FMVSS 223 REAR IMPACT GUARDS 2007 TRANSFREIGHT TECHNOLOGY NHTSA NO. REPORT NO. SAFETY COMPLIANCE TESTING FOR FMVSS 223 REAR IMPACT GUARDS 2007 TRANSFREIGHT TECHNOLOGY NHTSA NO. RIG 009 PREPARED BY: KARCO ENGINEERING, LLC. 9270 HOLLY ROAD ADELANTO, CALIFORNIA 92301 SEPTEMBER

More information

Compliance Certification Services Inc. Report No: MIL(CS101) Date of Issue: August 12, 2009 MIL STD 461E/ F TEST REPORT.

Compliance Certification Services Inc. Report No: MIL(CS101) Date of Issue: August 12, 2009 MIL STD 461E/ F TEST REPORT. Compliance Certification Services Inc. MIL STD 461E/ F TEST REPORT For 20.1 Multimedia LCD Monitor Model Number: WMRM920-PIP Trade Name: itech Issued to itech Company LLC 41758 Christy Street, Fremont

More information

Lightweight Shock Test Report on Power Supply PS1503-H-MB and Adapter Plate for Powerstar Inc. Gaithersburg, MD

Lightweight Shock Test Report on Power Supply PS1503-H-MB and Adapter Plate for Powerstar Inc. Gaithersburg, MD Test Report No. 11543.1 No. of Pages 14 Lightweight Shock Test Report on Power Supply PS1503-H-MB and Adapter Plate for Powerstar Inc. Gaithersburg, MD NU LABORATORIES 312 Old Allerton Road, Annandale,

More information

Reliability Test Report

Reliability Test Report Reliability Test Report Page 1 of 29 Reliability flow Chart: Page 2 of 29 Test Group 1 1.1 Dimensional Analysis: 1.1.1 Test Purpose: These measurements are to verify that the units meet the dimensional

More information

Model 6 Weld-On Drawbar Eye

Model 6 Weld-On Drawbar Eye MANUFACTURING CO. THE FIRST NAME IN QUALITY COUPLINGS Installation, Inspection, Operation & Maintenance Guide Model 6 Weld-On Drawbar Eye IMPORTANT Read these instructions completely before installing,

More information

National Board Update

National Board Update National Board Update Presentation to the Valve Repair Council June 2, 2016 Prepared by: Joseph F. Ball, P.E. National Board Update National Board activities Who we are and what we do National Board Inspection

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 NATIONAL EXPOSURE TESTING, INC. 3211 Centennial Road Sylvania, OH 43560 Christa Lammers Phone: 419 841 1065 MECHANICAL Valid To: October 31, 2018 Certificate

More information

Lightweight Shock and Type I Vibration Test Report on UPS Model No. PS3200RM for Powerstar Inc. Gaithersburg, MD

Lightweight Shock and Type I Vibration Test Report on UPS Model No. PS3200RM for Powerstar Inc. Gaithersburg, MD Test Report No. 12069.1 No. of Pages 21 Lightweight Shock and Type I Vibration Test Report on UPS Model No. PS3200RM for Powerstar Inc. Gaithersburg, MD NU LABORATORIES 312 Old Allerton Road, Annandale,

More information

Conductor Strength Tests on ACCR 1622TW T13 Pecos Conductor

Conductor Strength Tests on ACCR 1622TW T13 Pecos Conductor Conductor Strength Tests on ACCR 1622TW T13 Pecos Conductor 3M HCC Testing Laboratory August 5, 2011 Phu Trac Sr. Quality Engineer: Phu Trac Technical Manager: Dr. Herve Deve Lead Development Specialist:

More information

NATIONAL TECHNICAL SYSTEMS

NATIONAL TECHNICAL SYSTEMS Test Report Number 41418-09.PPC Testing of Pancake Alternator & PMU PREPARED FOR: The Perfect Parts Company Sullivan Products 1 North Haven Street Baltimore, MD 21224 PREPARED BY: National Technical Systems

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 NATIONAL EXPOSURE TESTING, INC. 3211 Centennial Road Sylvania, OH 43560 Christa Lammers Phone: 419 841 1065 MECHANICAL Valid To: October 31, 2016 Certificate

More information

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key!

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key! 655 Door with Key SERIES Related Information General terms and conditions... F-7 General precautions... P.50 PHOTO PHOTO Conforming to Machine & EMC Directives Recognition Certified MEASURE ITY panasonic.net/id/pidsx/global

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Intelligent Flow Measurement Your Sole Source for Badger Differential Producers Worldwide 6 Blackstone Valley Place, Lincoln RI 02865-1162 Ph: 401 334 1170 Fx: 401 334 1173 Em: solutions@wyattflow. Installation,

More information

CALIBRATION REPORT. Rendered to: United States Aluminum Corp. LOCATION: Waxahachie, Texas

CALIBRATION REPORT. Rendered to: United States Aluminum Corp. LOCATION: Waxahachie, Texas CALIBRATION REPORT Rendered to: United States Aluminum Corp. LOCATION: Waxahachie, Texas Report No.: 79241.01-801-47 Calibration Date: 12/14/07 Report Date: 03/20/08 2865 Market Loop Southlake, Texas 76092

More information

No , Vers.1

No , Vers.1 Pag. 1 of 4 TEST REPORT No. Test performed in accordance with the standard ASTM B 117 (2003) issued by TÜV Rheinland Italia S.r.l. - Via Gavardina Trav. II, 42 I-25010 Ponte S. Marco (BS) 1. General information

More information

MEASUREMENT AND TEST REPORT

MEASUREMENT AND TEST REPORT IES LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT For Guangzhou Hongli Opto-Electronic Co., Ltd. West side of Dongfeng Highway, Automobile industrial Base, Huadu

More information

TEST REPORT. Rendered to: HOMELAND VINYL PRODUCTS, INC. For: PVC Guardrail System Utilizing New Nylon/PVC Rail Mounting Bracket

TEST REPORT. Rendered to: HOMELAND VINYL PRODUCTS, INC. For: PVC Guardrail System Utilizing New Nylon/PVC Rail Mounting Bracket TEST REPORT Rendered to: HOMELAND VINYL PRODUCTS, INC. For: PVC Guardrail System Utilizing New Nylon/PVC Rail Mounting Bracket Report No: Report Date: 10/31/12 130 Derry Court York, PA 17406-8405 phone:

More information

TEST EQUIPMENT USED. Part , ANSI C63.4, RSS 210

TEST EQUIPMENT USED. Part , ANSI C63.4, RSS 210 EXHIBIT 6 Test Equipment Used CFS8DLLGB500 / 573F-LGB500 TEST EQUIPMENT USED Part 15.231, ANSI C63.4, RSS 210 This is a list of all test equipment used for non-radiated testing. Equipment used for radiated

More information

THERMAL SHOCK TEST REPORT

THERMAL SHOCK TEST REPORT Report No. :DH1509300024A Version:A THERMAL SHOCK TEST REPORT Company :FLIP CHIP OPTO. INC. Address :No.185, Kewang Rd., Longtan Dist., Taoyuan City 325, Taiwan (R.O.C.) Model Name :Apollo 600-B Lot Number

More information

National comparison on verification of fuel dispensers

National comparison on verification of fuel dispensers 16 th International Congress of Metrology, 06011 (2013) DOI: 10.1051/ metrology/201306011 C Owned by the authors, published by EDP Sciences, 2013 National comparison on verification of fuel dispensers

More information

SAMTEC POWER CHARACTERIZATION

SAMTEC POWER CHARACTERIZATION Project Number: Tracking Code: Power Report Rev 3 Requested by: Eric Mings Date: 9/11/2012 Product Rev: AE Part #: MMSD-25-24-L-12.00-D-K-LUS Lot #: «Lot_Number» Tech: Tony Wagoner Eng: Eric Mings Part

More information

SAMTEC POWER CHARACTERIZATION

SAMTEC POWER CHARACTERIZATION Project Number: Tracking Code: Report Rev 3 Requested by: Eric Mings Date: 5/20/2013 Product Rev: 0 Part #: ET60T-00-24-06-L-RT-GP Tech: Tony Wagoner Eng: Eric Mings Part description: R/A Plug Ten60 Power

More information

Cyclic Corrosion Test CORR Series

Cyclic Corrosion Test CORR Series Cyclic Corrosion Test CORR Series CCT 1300 CORR image merely illustrative Specifications/Model CCT 1300 CORR CCT 3000 CORR CCT 5000 CORR - Mode: SALT SPRAY / SALT FOG - Mode: WATER CONDENSATION HUMIDITY

More information

Test Report. for. Chilicon Power 1563 Calle Patricia Pacific Palisades, CA USA. Project Number: G Prepared By:

Test Report. for. Chilicon Power 1563 Calle Patricia Pacific Palisades, CA USA. Project Number: G Prepared By: Test Report for Chilicon Power 1563 Calle Patricia Pacific Palisades, CA 90272 USA Project Number: G100834560 Prepared By: Intertek 1500 Brigantine Drive Coquitlam, B.C. V3K 7C1 Canada Intertek Testing

More information

Aug07 Rev A All Paragraphs Revised

Aug07 Rev A All Paragraphs Revised Qualification Test Report Universal MATE-N-LOK* Connector 110-213 28Aug07 Rev A All Paragraphs Revised 1. INTRODUCTION 1.1. Purpose 1.2. Scope Testing was performed on Universal MATE-N-LOK* connectors

More information

Model 123 Weld-On Adjustable Drawbar Eye

Model 123 Weld-On Adjustable Drawbar Eye MANUFACTURING CO. THE FIRST NAME IN QUALITY COUPLINGS Installation, Inspection, Operation & Maintenance Guide Model 123 Weld-On Adjustable Drawbar Eye IMPORTANT Read these instructions completely before

More information

GM Specification Annual Test Data

GM Specification Annual Test Data GM Specification Annual Test Data GM Specification Annual Test Data Technical Bulletin The 3M IATD Quality Laboratory tested the following tapes to the Automotive Specification. The results of the testing

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. AUTO TECHNOLOGY COMPANY Progress Drive Strongsville, OH Kevin Smith MECHANICAL

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. AUTO TECHNOLOGY COMPANY Progress Drive Strongsville, OH Kevin Smith MECHANICAL SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 AUTO TECHNOLOGY COMPANY 20026 Progress Drive Strongsville, OH 44149 Kevin Smith 440 572 7800 MECHANICAL Valid To: December 31, 2013 Certificate Number: 2563.02

More information

Payload Magnetometer Thermal Vacuum Procedure. GP-B Procedure P0897 Rev -

Payload Magnetometer Thermal Vacuum Procedure. GP-B Procedure P0897 Rev - P0897 Rev - Page 1 of 8 W. W. Hansen Experimental Physics Laboratory STNFORD UNIVERSITY STNFORD, CLIFORNI 94305-4085 Gravity Probe B Relativity Mission Payload Magnetometer Thermal Vacuum Procedure GP-B

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 DURHAM HOLDINGS CORPORATION INC. DBA MME TESTING 1039 Industrial Court Suwanee, GA 30024 Danny Collazo Phone: 678 730 2000 MECHANICAL Valid To: October 31,

More information

Introduction. Figure 1: Labeled picture of the Instron 3367 load frame.

Introduction. Figure 1: Labeled picture of the Instron 3367 load frame. Operation of the Instron Tensile Test Machine With an Existing Method in Bluehill 3 Software Introduction by Andrew E. Frerichs, 3/25/11 Michelle Grawe; 10/6/14 Introduction The Instron device is a displacement

More information

GM Specification Annual Test Data

GM Specification Annual Test Data GM Specification Annual Test Data GM Specification Annual Test Data Technical Bulletin The 3M IATD Quality Laboratory tested the following tapes to the Automotive Specification. The results of the testing

More information

Welcome to Garber C O R P O R AT E O V E R V I E W

Welcome to Garber C O R P O R AT E O V E R V I E W CORPORATE OVERVIEW Garber Metrology is one of the only companies in the Mid-Atlantic Region that combines full service weighing solutions, a wide range of calibration /metrology services and a broad scope

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Charter Coating Service (2000) Ltd. Suite

More information

ANSI/AGRSS Automotive Glass Replacement Safety Standard

ANSI/AGRSS Automotive Glass Replacement Safety Standard ANSI/AGRSS 002-2002 1. Scope and purpose 1.1 Scope AutoGlassReplacement To develop and publish nationally-recognized automotive glass replacement safety standards addressing procedures, education, and

More information

Model 240K / 240KL Coupling

Model 240K / 240KL Coupling MANUFACTURING CO. THE FIRST NAME IN QUALITY COUPLINGS Installation, Inspection, Operation & Maintenance Guide Model 240K / 240KL Coupling IMPORTANT Read these instructions completely before installing,

More information

GENERAL SPECIFICATION

GENERAL SPECIFICATION ALPHA 2001 MD TMA (Truck Mounted Attenuator GENERAL SPECIFICATION I. GENERAL A. All ALPHA 2001 MD Truck Mounted Attenuators (ALPHA 2001 MD TMA) shall be designed and manufactured by Energy Absorption systems,

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. AUTO TECHNOLOGY COMPANY Progress Drive Strongsville, OH Kevin Smith MECHANICAL

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. AUTO TECHNOLOGY COMPANY Progress Drive Strongsville, OH Kevin Smith MECHANICAL SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 AUTO TECHNOLOGY COMPANY 20026 Progress Drive Strongsville, OH 44149 Kevin Smith 440 572 7800 MECHANICAL Valid To: December 31, 2019 Certificate Number: 2563.02

More information

Salt Spray Test Chamber Model SSe CASS/AASS ASTM B 368 ISO 9227 JIZ 2371

Salt Spray Test Chamber Model SSe CASS/AASS ASTM B 368 ISO 9227 JIZ 2371 Salt Spray Test Chamber Model SSe CASS/AASS ASTM B 368 ISO 9227 JIZ 2371 Specification/Model SS600e CASS/AASS SS1000e CASS/AASS SS1300e CASS/AASS SS3000e CASS/AASS Chamber Temperature Range Ambient + 9

More information

ASTM B117 Testing Quality Control

ASTM B117 Testing Quality Control ASTM B117 Testing Quality Control ASTM B117 Testing, also known as a Standard Practice for Operating Salt Spray (Fog), is used to analyze relative corrosion for specimens of metals and coated metals exposed

More information

FEBRRUARY 22, 2008 TEST REPORT # QSH/QTH/QTE SERIES CONNECTOR SHEAR TESTING SAMTEC, INC.

FEBRRUARY 22, 2008 TEST REPORT # QSH/QTH/QTE SERIES CONNECTOR SHEAR TESTING SAMTEC, INC. FEBRRUARY 22, 2008 TEST REPORT #207908 QSH/QTH/QTE SERIES CONNECTOR SHEAR TESTING SAMTEC, INC. APPROVED BY: DOMINIC ARPINO PROGRAM MANAGER CONTECH RESEARCH, INC. Contech Research REVISION HISTORY DATE

More information

Automated Liquid Handling Station

Automated Liquid Handling Station Automated Liquid Handling Station Quick Installation Guide Manual Part Number 32-0406-048 Rev 0 COPYRIGHT 2018 Teledyne Technologies Incorporated. All rights reserved. 32-0406-048 Rev 0, May, 2018 Printed

More information

mga research corporation

mga research corporation mga research corporation UNDERGROUND TECHNOLOGIES MAN-HOLE CONSTRUCTION VERTICAL STATIC LOAD TEST SERIES (PO# 11521) 446 executive drive troy, mi 48083 248 / 577-5001 fax 248 / 577-5025 www.mgaresearch.com

More information

ALPHA 70K TMA (Truck Mounted Attenuator) GENERAL SPECIFICATIONS

ALPHA 70K TMA (Truck Mounted Attenuator) GENERAL SPECIFICATIONS ALPHA 70K TMA (Truck Mounted Attenuator) GENERAL SPECIFICATIONS I. GENERAL A. All ALPHA 70K Truck Mounted Attenuators (ALPHA 70K TMA) shall be designed and manufactured by Energy Absorption Systems, Incorporated,

More information

Policy Bulletin No. 25 Net Metering. Public Utility District No. 1 of Klickitat County 1313 South Columbus Goldendale, WA 98620

Policy Bulletin No. 25 Net Metering. Public Utility District No. 1 of Klickitat County 1313 South Columbus Goldendale, WA 98620 Policy Bulletin No. 25 Net Metering Public Utility District No. 1 of Klickitat County 1313 South Columbus Goldendale, WA 98620 Interconnection Standards For Residential Net Energy Metering With Electric

More information

TEST REPORT. Report No.: G Rendered to: VELUX America LLC Greenwood, South Carolina

TEST REPORT. Report No.: G Rendered to: VELUX America LLC Greenwood, South Carolina TEST REPORT Report No.: G4212.01-109-44 Rendered to: VELUX America LLC Greenwood, South Carolina PRODUCT TYPE: Skylight with Curb SERIES/MODEL: Specials Dome Skylight 0.118 thickness PC smooth/0.118 thickness

More information

Model 2200ELL Coupling

Model 2200ELL Coupling MANUFACTURING CO. THE FIRST NAME IN QUALITY COUPLINGS Installation, Inspection, Operation & Maintenance Guide Model 2200ELL Coupling IMPORTANT Read these instructions completely before installing, using

More information

JJG Translated English of Chinese Standard: JJG

JJG Translated English of Chinese Standard: JJG Translated English of Chinese Standard: JJG646-2006 www.chinesestandard.net Sales@ChineseStandard.net National Metrological Verification Regulation of the People's Republic of China JJG JJG 646-2006 Locomotive

More information

Selecting Weights and Certificates

Selecting Weights and Certificates 11 Weight Selection There are several shapes, designs and sizes available to meet your needs. Selecting the proper weight for your application can be confusing given the number of weight classes, designs,

More information

3M Three-Wall and Four-Wall Headers. Series 3XXX

3M Three-Wall and Four-Wall Headers. Series 3XXX 1 of 7 M Three-Wall and Four-Wall Headers Series XXX Product 78-10-0008-0 Released: 0-0-11 of 7 Table of Contents Section Page 1. Scope........ M Customer Documents....... Performance and Test Descriptions...

More information

Test Report Current (Gen 2) Pendant Armor and Gen 3 Pendant Armor Polymer A Hanger and Polymer B Hanger March 16, 2016 (Q022516U1R2) Testing Location

Test Report Current (Gen 2) Pendant Armor and Gen 3 Pendant Armor Polymer A Hanger and Polymer B Hanger March 16, 2016 (Q022516U1R2) Testing Location Client Roboworld Molded Products, LLC 8216 Pricinceton-Glendale Road, Suite 246 West Chester, OH 45069 Test Report Current (Gen 2) Pendant Armor and Gen 3 Pendant Armor Polymer A Hanger and Polymer B Hanger

More information

Australian Standard. Cranes, hoists and winches. Part 18: Crane runways and monorails. AS (Incorporating Amendment Nos 1 and 2)

Australian Standard. Cranes, hoists and winches. Part 18: Crane runways and monorails. AS (Incorporating Amendment Nos 1 and 2) AS 1418.18 2001 (Incorporating Amendment Nos 1 and 2) AS 1418.18 Australian Standard A1 Cranes, hoists and winches Part 18: Crane runways and monorails This Australian Standard was prepared by Committee

More information

POST-WELD TREATMENT OF A WELDED BRIDGE GIRDER BY ULTRASONIC IMPACT TREATMENT

POST-WELD TREATMENT OF A WELDED BRIDGE GIRDER BY ULTRASONIC IMPACT TREATMENT POST-WELD TREATMENT OF A WELDED BRIDGE GIRDER BY ULTRASONIC IMPACT TREATMENT BY William Wright, PE Research Structural Engineer Federal Highway Administration Turner-Fairbank Highway Research Center 6300

More information

Model 580 / 580J Coupling

Model 580 / 580J Coupling MANUFACTURING CO. THE FIRST NAME IN QUALITY COUPLINGS Installation, Inspection, Operation & Maintenance Guide Model 580 / 580J Coupling IMPORTANT Read these instructions completely before installing, using

More information

CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF TORQUE METROLOGY (Torque Generating Device Calibration)

CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF TORQUE METROLOGY (Torque Generating Device Calibration) CRITERIA FOR LABORATORY ACCREDITATION IN THE FIELD OF TORQUE METROLOGY (Torque Generating Device Calibration) Approved By: Chief Executive Officer: Ron Josias Executive - Accreditation: Mpho Phaloane Author:

More information

SG-B1 SERIES / SG-A1 SERIES

SG-B1 SERIES / SG-A1 SERIES 643 Door with Solenoid Interlock / Door Ultra-slim SG-B1 SERIES / SG-A1 SERIES Related Information General terms and conditions... F-7 General precautions... P.1501 PHOTO PHOTO Conforming to Machine &

More information

Cyclic Corrosion Chamber C.C.T AUTO Series

Cyclic Corrosion Chamber C.C.T AUTO Series Cyclic Corrosion Chamber C.C.T AUTO Series CCT 5000 AUTO image merely illustrative Cooling system image merely illustrative Specifications/ Models CCT 1300 AUTO CCT 3000 AUTO CCT 5000 AUTO Allows 7 different

More information

Rated voltage: 100~277 VAC Frequency: 50/60Hz Wattage: 14 W

Rated voltage: 100~277 VAC Frequency: 50/60Hz Wattage: 14 W Customer Company & Address: MaxLite ADD: 12 York Ave, West Caldwell, NJ 07006 Contact Person: Francisco Garza Telephone: 973-244-7300x142 Telephone: fgarza@maxlite.com Manufacturer: Country of Origin:

More information

AS/NZS :2011. Gate valves for waterworks purposes AS/NZS :2011. Part 1: Metal seated. Australian/New Zealand Standard

AS/NZS :2011. Gate valves for waterworks purposes AS/NZS :2011. Part 1: Metal seated. Australian/New Zealand Standard AS/NZS 2638.1:2011 Incorporating Amendment No. 1 Australian/New Zealand Standard Gate valves for waterworks purposes Part 1: Metal seated AS/NZS 2638.1:2011 AS/NZS 2638.1:2011 This joint Australian/New

More information

3M Connector System 0.050" x 0.100" Pitch. 3M Tripolarized Wiremount Socket - Series 820 3M 4-Wall, Tripolarized Header - Series 810

3M Connector System 0.050 x 0.100 Pitch. 3M Tripolarized Wiremount Socket - Series 820 3M 4-Wall, Tripolarized Header - Series 810 1 of 9 3M Connector System 0.050" x 0.100" Pitch 3M Tripolarized Wiremount Socket - Series 820 3M 4-Wall, Tripolarized Header - Series 810 Product Specification 78-5110-0074-0 Released: 10-1-10 2 of 9

More information

Tex-614-J, Testing Epoxy Materials

Tex-614-J, Testing Epoxy Materials Overview Effective Date: January 2001 - July 2002. This method covers various test procedures for epoxy materials specified under the TxDOT Material Specification "DMS-6100, Epoxies and Adhesives." The

More information

ANSI/BIFMA X Desk/Table Products - Tests. American National Standard for Office and Institutional Furnishings

ANSI/BIFMA X Desk/Table Products - Tests. American National Standard for Office and Institutional Furnishings BSR/BIFMA X5.5-201X ANSI/BIFMA X5.5-2014 Desk/Table Products - Tests American National Standard for Office and Institutional Furnishings American National Standard Approval of an American National Standard

More information

NFPA 286 STANDARD METHODS OF FIRE TESTS FOR EVALUATING CONTRIBUTION OF WALL AND CEILING INTERIOR FINISH TO ROOM FIRE GROWTH

NFPA 286 STANDARD METHODS OF FIRE TESTS FOR EVALUATING CONTRIBUTION OF WALL AND CEILING INTERIOR FINISH TO ROOM FIRE GROWTH NFPA 286 STANDARD METHODS OF FIRE TESTS FOR EVALUATING CONTRIBUTION OF WALL AND CEILING INTERIOR FINISH TO ROOM FIRE GROWTH Contego Latex Fire Barrier Intumescent (Also marketed in Canada by Pyrologistics,

More information

Tex-614-J, Testing Epoxy Materials

Tex-614-J, Testing Epoxy Materials Overview Effective: August 1999 May 2000. This method covers various test procedures for epoxy materials specified under the TxDOT Material Specification DMS-6100, Epoxies and Adhesives. The test to be

More information

SAFETY COMPLIANCE TESTING FOR FMVSS NO. 401 INTERIOR TRUNK RELEASE

SAFETY COMPLIANCE TESTING FOR FMVSS NO. 401 INTERIOR TRUNK RELEASE REPORT NUMBER 401-STF-09-002 SAFETY COMPLIANCE TESTING FOR FMVSS NO. 401 INTERIOR TRUNK RELEASE HYUNDAI MOTOR COMPANY 2009 HYUNDAI GENESIS FOUR-DOOR PASSENGER CAR NHTSA NO. C90501 U.S. DOT SAN ANGELO TEST

More information

SIGMAZINC 109. PRODUCT DATA SHEET January 16, 2015 (Revision of January 5, 2015) DESCRIPTION. Two-component, zinc-rich, polyamide-cured epoxy primer

SIGMAZINC 109. PRODUCT DATA SHEET January 16, 2015 (Revision of January 5, 2015) DESCRIPTION. Two-component, zinc-rich, polyamide-cured epoxy primer DESCRIPTION Two-component, zinc-rich, polyamide-cured epoxy primer PRINCIPAL CHARACTERISTICS Designed as a system primer for various paint systems Good corrosion prevention properties Quick-drying, can

More information

DESIGN VERIFICATION TEST REPORT HLE/TSM HLE G-DV/TSM G-DV

DESIGN VERIFICATION TEST REPORT HLE/TSM HLE G-DV/TSM G-DV Project Number: Design Verification Test Report Tracking Code: _Report_Rev_1 Requested by: Mark Shireman Date: 9/30/2010 Product Rev: 0 Lot #: na Tech: Tony Wagoner Eng: Eric Mings Qty to test: 15 Test

More information

ANSI/AGRSS Automotive Glass Replacement Safety Standard

ANSI/AGRSS Automotive Glass Replacement Safety Standard ANSI/AGRSS 003-2009 Automotive Glass Replacement Safety Standard 1. Scope and purpose 1.1 Scope To develop and publish nationally-recognized automotive glass replacement safety standards addressing procedures,

More information

IES LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES

IES LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES IES LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT For Guangzhou Hongli Opto-Electronic Co., Ltd. West side of Dongfeng Highway, Automobile industrial Base, Huadu

More information

EZ SDI TM Booster Pump Assembly

EZ SDI TM Booster Pump Assembly EZ SDI TM Booster Pump Assembly Installation and Operating Manual 505-334-5865 ph 505-334-5867 fax www.rodisystems.com email: info@rodisystems.com 936 Highway 516 Aztec, NM 87410-2828 Manual Revisions

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ELEMENT MATERIALS TECHNOLOGY MINNEAPOLIS LLC (A subsidiary of Element Materials Technology Minneapolis Inc.) 9725 Girard Avenue South Minneapolis, MN 55431

More information

SFI SPECIFICATION 28.1 EFFECTIVE: AUGUST 25, 2017 *

SFI SPECIFICATION 28.1 EFFECTIVE: AUGUST 25, 2017 * SFI SPECIFICATION 28.1 EFFECTIVE: AUGUST 25, 2017 * PRODUCT: Polymer (Foam-Filled) Fuel Cells 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes uniform test procedures and minimum standards

More information

AS/NZS 3112:2004 AS/NZS

AS/NZS 3112:2004 AS/NZS AS/NZS 3112:2011 Incorporating Amendment No. 1, 2, and 3 Australian/New Zealand Standard Approval and test specification Plugs and socket-outlets Superseding AS/NZS 3112:2004 AS/NZS 3112:2011 AS/NZS 3112:2011

More information

SAFETY COMPLIANCE TESTING FOR FMVSS NO. 401 INTERIOR TRUNK RELEASE

SAFETY COMPLIANCE TESTING FOR FMVSS NO. 401 INTERIOR TRUNK RELEASE REPORT NUMBER 401-STF-09-001 SAFETY COMPLIANCE TESTING FOR FMVSS NO. 401 INTERIOR TRUNK RELEASE GENERAL MOTORS CORPORATION 2009 CHEVROLET IMPALA FOUR-DOOR PASSENGER CAR NHTSA NO. C90100 U.S. DOT SAN ANGELO

More information

QUALIFICATION TEST REPORT

QUALIFICATION TEST REPORT Meggitt (North Hollywood), Inc. Meggitt (North Hollywood), Inc. 12838 Saticoy Street, North Hollywood California 91605 QUALIFICATION TEST REPORT FOR NOZZLE, PRESSURE FUELING Meggitt Controls Part Number:

More information

DEMCO Resilient-Seated Butterfly Valve

DEMCO Resilient-Seated Butterfly Valve Document Number: TC003001-01 Revision: Rev 2 DEMCO Resilient-Seated Butterfly Valve Installation, Operation, and Maintenance Manual TABLE OF CONTENTS BILL OF MATERIALS... 3 SCOPE... 5 NAMEPLATE INFORMATION...

More information

SFI SPECIFICATION 35.2 EFFECTIVE: DECEMBER 29, 2014 *

SFI SPECIFICATION 35.2 EFFECTIVE: DECEMBER 29, 2014 * SFI SPECIFICATION 35.2 EFFECTIVE: DECEMBER 29, 2014 * PRODUCT: Heavy Duty Stock Car Steel Wheels 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes uniform test procedures and minimum standards

More information

TEST REPORT UL Fire test for Heat and Visible Smoke Release for Discrete Products and Their Accessories Installed in Air-Handling Spaces

TEST REPORT UL Fire test for Heat and Visible Smoke Release for Discrete Products and Their Accessories Installed in Air-Handling Spaces UL 2043 TEST REPORT Fire test for Heat and Visible Smoke Release for Discrete Products and Their Accessories Installed in Air-Handling Spaces Pipe Fixings TSMI TSMI Non-metallic Tubing Channel Clip for

More information

DETAIL SPECIFICATION SHEET

DETAIL SPECIFICATION SHEET INCHPOUND MILDTL85052/1C 30 March 2005 SUPERSEDING MILC85052/1B 30 MAY 1984 DETAIL SPECIFICATION SHEET CLAMP, LOOP, TUBE177 PH CRES, 275 o F, FUEL AND PETROLEUM BASED HYDRAULIC FLUID RESISTANT This specification

More information

COMMERCIAL ITEM DESCRIPTION HOSE AND HOSE ASSEMBLIES, NONMETALLIC SPRAY

COMMERCIAL ITEM DESCRIPTION HOSE AND HOSE ASSEMBLIES, NONMETALLIC SPRAY [INCH-POUND] A-A-59613 August 16, 2001 SUPERSEDING ZZ-H-521F May 28, 1993 COMMERCIAL ITEM DESCRIPTION HOSE AND HOSE ASSEMBLIES, NONMETALLIC SPRAY The General Services Administration has authorized the

More information

JUL 14 Rev B

JUL 14 Rev B Power Triple Lock (PTL) Connector System Application Specification 4-068 2 JUL 4 Rev B NOTE All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters.

More information

Summary of HALT, IPx7 & IP69K testing for AT Series connectors

Summary of HALT, IPx7 & IP69K testing for AT Series connectors S1-15227 Rev. A1 Corp. SINE Systems Corporation 44724 Morley Drive Clinton Twp, MI 48036 Summary of HALT, IPx7 & IP69K testing for AT Series connectors IPx7 (Submersion) PASS Requirements: Acceptance conditions

More information

SHOCK TEST REPORT. Report No. : ENVA S9 Model Number : S9

SHOCK TEST REPORT. Report No. : ENVA S9 Model Number : S9 Report No. : ENVA10072605 S9 Model Number : S9 Page: 1 of 6 Product Name : S9 Model Number : S9 Date of Receipt : Jul. 26, 2010 Finished date of Test : Jul. 26, 2010 We, Spectrum Research & Testing Laboratory

More information

Photograph 1, Current feed to connector test loop

Photograph 1, Current feed to connector test loop Photograph 1, Current feed to connector test loop Photograph 2, control conductor and instrument leads outside test chamber Page 3 of 6 Photograph 3 Salt Fog Chamber with Connector Loop Photograph 4, Connector

More information

Fluid Sealing Association

Fluid Sealing Association Fluid Sealing Association STANDARD FSA-DSJ-401-09 SPECIFICATION FOR HIGH TEMPERATURE AND ACID RESISTANT TERPOLYMER FLUOROELASTOMER REVISED OCTOBER, 2009 994 Old Eagle School Road, Suite 1019 Wayne, Pennsylvania

More information

United States Stove Company Project # Model: KP60 AKA: AP60, VG60 Type: Pellet-Fired Room Heater May 31, 2018

United States Stove Company Project # Model: KP60 AKA: AP60, VG60 Type: Pellet-Fired Room Heater May 31, 2018 United States Stove Company Project # 18-409 AKA: AP60, VG60 Type: Pellet-Fired Room Heater May 31, 2018 ASTM E2779 Standard Test Method for Determining Particulate Matter Emissions from Pellet Heaters

More information

Saf-Tite Coupling

Saf-Tite Coupling MANUFACTURING CO. THE FIRST NAME IN QUALITY COUPLINGS Installation, Inspection, Operation & Maintenance Guide Raising the Bar SAF TITE Strength & Value Saf-Tite 100-3 Coupling IMPORTANT Read these instructions

More information

AWRF Associated Wire Rope Fabricators

AWRF Associated Wire Rope Fabricators AWRF Associated Wire Rope Fabricators Recommended Practice and Guideline Disclaimer for version of AWRF Recommended Guideline for Proof Test Procedures for Slings Part I: Alloy Chain Slings Associated

More information

TEST REPORT. Report No.: G Rendered to: SKYCO SKYLIGHTS Costa Mesa, California

TEST REPORT. Report No.: G Rendered to: SKYCO SKYLIGHTS Costa Mesa, California TEST REPORT Report No.: G1418.01-301-44 Rendered to: SKYCO SKYLIGHTS Costa Mesa, California PRODUCT TYPE: Fall Protection Security Bars SERIES/MODEL: FSB-1A/FSB-10A/FSB-1/FSB-10 SPECIFICATION: Occupational

More information

SIGMAZINC 105. PRODUCT DATA SHEET December 15, 2014 (Revision of July 1, 2013) DESCRIPTION. Two-component, zinc epoxy primer PRINCIPAL CHARACTERISTICS

SIGMAZINC 105. PRODUCT DATA SHEET December 15, 2014 (Revision of July 1, 2013) DESCRIPTION. Two-component, zinc epoxy primer PRINCIPAL CHARACTERISTICS DESCRIPTION Two-component, zinc epoxy primer PRINCIPAL CHARACTERISTICS Excellent anticorrosive properties Quick-drying, can be overcoated after 25 minutes Excellent application properties Cures at temperatures

More information