1 National Board Update Presentation to the Valve Repair Council June 2, 2016 Prepared by: Joseph F. Ball, P.E.

2 National Board Update National Board activities Who we are and what we do National Board Inspection Code (NBIC) Updates National Board Test Lab updates New Certified Testing Organization (TO) program

3 National Board Activities CERTIFICATION Pressure relief device capacity cert. program COMMISSIONING boiler and pressure vessel inspectors through its Commission Examination TRAINING boiler and pressure vessel inspectors EDUCATING the general public and government representatives on the need for safety Standards, and tracking violations The National board is comprised of Chief Boiler Inspectors representing government Agencies from across the United States & Canada. National Board Activities include: ASSISTING in the establishment of manufacturing, maintenance and repair standards for boiler and pressure vessels REGISTERING all manufactured boilers and pressure vessels INVESTIGATING accidents involving boilers and pressure vessels 3

4 National Board Inspection Code (NBIC) Updates New format for all Administrative requirements VR program rules to NB-514 R stamp program to NB-415 NR program to NB Additions Part 1: Installation requirements for Biomass boilers and thermal fluid heaters added Part 2: Added supplement on Change of Service Added supplement on Inspection of high pressure vessels includes AE testing procedures

5 NBIC Updates (cont.) 2015 Additions Part 3 NR program updated repairs broken into three categories 1. Repairs prior to fuel loading 2. Systems under ASME Section XI (after fuel loading) 3. Items constructed to standards other than ASME Updated NBIC repair welding procedures Added Welding Method 6 for Grade 91 material

6 NBIC Ongoing Activities Preparation of NBIC Part 4 for Pressure Relief Devices Merges installation, inspection and repair requirements NBIC pressure relief initiatives Repair of tank vents Repair of pin devices Shelf life concerns for PRV s

7 Testing Laboratory Updates

8 Gas Supply Changed 6000 gallon liquid N2 storage vessel with pumps and vaporizer

9 Additional Gas storage with 6 new 4000 psig storage bottles approx. 70,000 SCFM additional capacity

10 1350 psig test system added (N2) in 3000 sq. ft. addition

11 High pressure air test system revised, rated at 2500 psi

12 220 HP natural gas steam generators, 900 psi, 6,000 PPH, plus preheater Steam System rebuilt

13 New feedwater system Feed water storage and D/A tank

14 Updated controls and DAQ system

15 NATIONAL BOARD TEST ORGANIZATION PROGRAM

16 Test Organization Program Authorized in Feb by National Board Board of Trustees Implements certification program for organizations that only perform In-Service testing of pressure relief valves Structure similar to VR program

17 Test Organization Program Formal program for Test Only process Development Goals Act as aid to Jurisdictions (Ref. Part 3 Supplement S7.10) Elevate standards and improve practices for the PRV testing process

18 Scope Program scope: certifies testing organizations who perform testing of in-service PRV s Provides specific qualification to make adjustments per NBIC Part 2, paragraph 2.5.7(g)

19 NBIC Part 2, par g) If a pressure test indicates the valve does not open within the requirements of the original code of construction, but otherwise is in acceptable condition, minor adjustments (defined as no more than twice the permitted set pressure tolerance) shall be made by an organization accredited by the National Board to reset the valve to the correct opening pressure. All adjustments shall be resealed with a seal identifying the responsible organization and a tag shall be installed identifying the organization and the date of the adjustment.

20 Program Details Quality program manual for testing process required Quality program needs to address in-service inspection Valve in good condition No broken or damaged parts Not leaking Seal(s) intact Test equipment must meet NBIC requirements Test vessel REQUIRED

21 Program Details Inspection and test to be documented on test report Test report to have unique identifier (test no.) TO symbol marked nameplate to be applied to valve that passes test Nameplate includes: Company name Test date Test number TO symbol Set Pressure

22 Program Details Valves that fail inspection or test (including leakage, outside of adjustment tolerance, or broken or missing seal) shall be repaired by a VR holder or be replaced.

23 TO sample test report ABC Test Company Inspection and Test Checklist for Pressure Relief Valves 1. Test Number 2. Customer Name 3. Address 4. Valve Type 5. Manufacturer 6. Set pressure 7. Size/ connection x 8. Serial Number 9.Capacity/ units 10. ASME/ NB/ VR Stamps: V UV NB VR 11. Last repair/ Date by Job. No. 12. Last test/ Date by Test No. Received by: Date Inspection Acceptable/ Action Req d 1. Set pressure seal intact Yes No 2. Adjusting ring(s) seal intact Yes N/A No 3. Seals match mfg. /repair/ test nameplate Yes No 4. Inspection and test done with valve: Removed Installed 5. Valve Condition: Clean Dirty Missing or damaged parts 6. Evidence valve is leaking No Yes 7. Evidence of rust or corrosion No Yes 8. Body drain open Yes No 9. Test gag found No Yes 10. Bonnet vented for bellows Yes N/A No 11. Drain pipe open Yes No 12. Binding of inlet or outlet piping No Yes 13. Discharge pipe support OK Yes No Inspected by: Date Test Data 1. Set Pressure Definition: Pop Aud. Disch. Bubble 1 st Steady Str. 2. Test method: Pop test Lift assist device 3. Test Fluid: Steam Air Water 4. Test Stand ID No. 5. Measured set press.: Tolerance:+/- Set pressure: Acceptable: Requires Adjustment Not acceptable 6. Final set press. after adjustment Tested by: 7. Seat leakage test method: API-527 Audible Visual Other 8. Seat Leakage result: Acceptable: Not acceptable 9. Seal applied/ identification: Yes ID No adj. made By 10: M&TE Serial Nos. 11: TO Nameplate applied: Yes No By: Date Remarks:

24 TO Sample Nameplate TO symbol is registered certification trademark TO organization can pre-apply mark to test plate Tested By: ABC Test Co. Test Date Test No. A Set Pressure 500 psig

25 Application process Application form submitted NB Representative conducts shop review Evaluates written description of Quality System (QC Manual) Verifies implementation of Quality System Observes tests of demonstration valves Demonstration valves submitted for verification testing of set pressure at NBBI-accepted lab

26 Comparison of TO to VR program VR program Can test and adjust valves Can change set pressure VR symbol applied only to valves that meet all repair requirements Can perform repair processes: machining, welding, NDE Can perform fluid changes or conversion TO program Can test and adjust valves Can restore original set pressure only TO symbol applied only to valves that pass test Cannot perform repairs Cannot perform fluid changes or conversion

27 Affect on VR Holders VR holder can get TO certification with application and QC manual update only (no application charge or additional test required) When needed, repairs must be done by VR holder Repairs cannot be performed under the TO program

28 Value of TO Certification? Benefits for test company User are confident of test organization s quality due to independent audit and comparison tests Differentiate company from non-certified organizations reduce user s need to perform audits Help with liability concerns by complying with National Standard

29 Value of TO Certification? Benefit to User organizations Provides confidence in the suppliers test data, lessens need for vendor audit Help document safety equipment in uniform fashion Help in meeting Jurisdictional/ Inspection Agency / Insurance carrier requirements

30 More Information NB-528 program document and application form to be added to National Board web page VR Course material being updated

31 Thank You for Having the National Board Here! Recognizing our shared objective: To promote safety through proper repair and rebuild Contact Info: Ph: Web page:

Safety relief valves and double stop valves, type SFVL and DSVL REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Safety relief valves and double stop valves, type SFVL and DSVL REFRIGERATION AND AIR CONDITIONING. Technical leaflet Safety relief valves and double stop valves, type and REFRIGERATION AND AIR CONDITIONING Technical leaflet Technical leaflet Introduction The safety valves are backpressure dependent pressure relief valves.

More information

Crosby Series 800 and 900 OMNI-TRIM Pressure Relief Valves. Flow Control

Crosby Series 800 and 900 OMNI-TRIM Pressure Relief Valves. Flow Control Crosby s Series 800 adjustable blowdown and Series 900 fixed blowdown OMNI-TRIM full nozzle pressure relief valves have a simplified, single trim design with superior application versatility. Features

More information

NBIC Inspection Tools for Historical Boilers

NBIC Inspection Tools for Historical Boilers NBIC Inspection Tools for Historical Boilers Joel T. Amato Chief Boiler Inspector Minnesota History Those who fail to learn from history are condemned to repeat it. Winston Churchill, 1948 speech to the

More information

KKAI Report No Rev 1 Prepared for BioHeatUSA April 28, 2009

KKAI Report No Rev 1 Prepared for BioHeatUSA April 28, 2009 1. Summary... 3 2. Background... 3 3. Scope... 3 4. European Suppliers... 4 5. Materials... 4 6. Design... 4 7. Fabrication... 5 8. Examination... 6 9. Inspection... 6 10. Testing... 8 11. Quality Control

More information

SECTION XI. Subject Interpretation File No.

SECTION XI. Subject Interpretation File No. SECTION XI Subject Interpretation File No. Appendix I, Supplement 9 (1995 Edition With the 1996 Addenda Through the 2005 Addenda).... XI-1-04-34 IN05-017 Appendix VIII, Qualification of Personnel With

More information

Second Class Chief Statutes and Rules

Second Class Chief Statutes and Rules Second Class Chief Statutes and Rules 326B.95 DEFINITIONS. Certificate of inspection. Certificate of inspection means a sticker attached to the boiler or pressure vessel which documents the month and year

More information

394C. Series 6400/6600. Safety Valves for Power Boiler Service

394C. Series 6400/6600. Safety Valves for Power Boiler Service 394C Series 6400/6600 Safety Valves for Power Boiler Service Series 6400/6600 Designed with the user in mind, Series 6400 and 6600 safety valves represent the most advanced technology in valves designed

More information

SAFETY VALVES. Series 560 & Aquatrol Safety/Relief Valves SERIES. ASME Section I & VIII - NB Certified for Air, Gas and Steam

SAFETY VALVES. Series 560 & Aquatrol Safety/Relief Valves SERIES. ASME Section I & VIII - NB Certified for Air, Gas and Steam SAFETY VALVES ASME Section I & VIII - NB Certified for Air, Gas and Steam SIZES FROM 1/2 TO 2 1/2 NB RATED TO 250# TEMPERATURES TO 406 O Aquatrol s Series / valve line is a high capacity safety valve used

More information

KINGSTON. Model 710. Side Outlet Safety Relief Valve. Manufacturing reliable industrial valves for industry since 1908.

KINGSTON. Model 710. Side Outlet Safety Relief Valve. Manufacturing reliable industrial valves for industry since 1908. KEst.1908 KINGSTON Manufacturing reliable industrial valves for industry since 1908. Model 710 Side Outlet Safety Relief Valve Storm Manufacturing Group, Inc. 23201 Normandie Ave., Torrance, CA 90501-5050

More information

Long Combination Vehicle (LCV) Exemption Permit Application

Long Combination Vehicle (LCV) Exemption Permit Application This application considers ALL National Safety Code (NSC) vehicles registered to your company that travel into, through or from Alberta and ALL drivers who operate those NSC vehicles, including those that

More information

Safety relief valves and double stop valves, type SFVL and DSVL REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Safety relief valves and double stop valves, type SFVL and DSVL REFRIGERATION AND AIR CONDITIONING. Technical leaflet Safety relief valves and double stop valves, type and REFRIGERATION AND AIR CONDITIONING Technical leaflet Technical leaflet Introduction The safety valves are backpressure dependent pressure relief valves.

More information

C.A.S.E. AIR CARRIER SECTION POLICIES AND PROCEDURES

C.A.S.E. AIR CARRIER SECTION POLICIES AND PROCEDURES INTO-PLANE AUDIT CHECKLIST Audit Date: Allocation #: Station Code: City: Vendor Name: Address: Primary Contact: Title: Phone: Fax: E-mail: Auditor: Acceptable: Conditionally Acceptable Not Acceptable Register:

More information

Pressure Relief Valve Maintenance Manual

Pressure Relief Valve Maintenance Manual Technical Manual 1098T Pressure Relief Valve Maintenance Manual Farris Engineering Division of Curtiss-Wright Flow Control Corporation TABLE OF CONTENTS - Manual Revision 0 Introduction & Safety Tips...

More information

Products and Services for the Energy Industry

Products and Services for the Energy Industry MC-3 DRESSER FLOW SOLUTIONS Products and Services for the Energy Industry The operations and major product lines of Dresser Flow Solutions make it an international leader in design, manufacturing and support

More information

Changes to Chapter , Florida Administrative Code Underground Storage Tank Systems (USTs) Effective 1/11/2017

Changes to Chapter , Florida Administrative Code Underground Storage Tank Systems (USTs) Effective 1/11/2017 Changes to Chapter 62-761, Florida Administrative Code Underground Storage Tank Systems (USTs) Effective 1/11/2017 Rule Organization The rule sections are reorganized a bit with separate sections now for:

More information

SV80H Safety and Relief Valves

SV80H Safety and Relief Valves Page 1 of 18 BR Rev.02 U SH Safety and Relief alves Description The SH is a full nozzle safety and relief valve with orifices D to T, comply with the API STD 526, beyond others with super capacity. Suitable

More information

RULE 448 GASOLINE TRANSFER INTO STATIONARY STORAGE CONTAINERS Adopted (Amended , , , , , ) INDEX

RULE 448 GASOLINE TRANSFER INTO STATIONARY STORAGE CONTAINERS Adopted (Amended , , , , , ) INDEX RULE 448 GASOLINE TRANSFER INTO STATIONARY STORAGE CONTAINERS Adopted 2-5-75 (Amended 9-15-75, 8-3-77, 9-2-80, 12-17-91, 2-2-95, 02-26-09) INDEX 100 GENERAL 101 PURPOSE 102 APPLICABILITY 110 EXEMPTION:

More information

POWER APPLICATION SSR-S1000

POWER APPLICATION SSR-S1000 POWER APPLICATION SSR-S1000 and SSR-S1100 COMPANY PSV is a company of PARCOL and SVC. PSV was founded in 2016 with the target of creating a flexible and high quality safety valve company. PSV combines

More information

CROSBY STYLE JB PRESSURE RELIEF VALVE

CROSBY STYLE JB PRESSURE RELIEF VALVE A large orifice pressure relief valve engineered to provide high quality, dependable overpressure protection for air, gas, vapor and steam applications FEATURES Ten size product range is the broadest available.

More information

MSC Guidelines for Fired Thermal Fluid Heaters Procedure Number: E1-28 Revision Date: April 20, 2018

MSC Guidelines for Fired Thermal Fluid Heaters Procedure Number: E1-28 Revision Date: April 20, 2018 References C. J. Robuck, LCDR, Chief, Engineering Division a. 46 CFR Part 52 Power Boilers b. 46 CFR Part 54 Pressure Vessels c. 46 CFR Part 63 Automatic Auxiliary Boilers Contact Information If you have

More information

* Contact your sales representative for compliance to NACE MR or later requirements.

* Contact your sales representative for compliance to NACE MR or later requirements. VALVES & CONTROLS crosby SERIES 800, 900 OMNI-TRIM, AND BP OMNI-TRIM Crosby s Series 800 adjustable blowdown, Series 900 fixed blowdown OMNI-TRIM, and BP OMNI-TRIM full nozzle pressure relief valves have

More information

SECTION GENERAL-SERVICE AIR COMPRESSOR PART 1 - GENERAL

SECTION GENERAL-SERVICE AIR COMPRESSOR PART 1 - GENERAL 13686.00 GENERAL SERVICE AIR COMPRESSOR 221519-1 SECTION 22 1519 - GENERAL-SERVICE AIR COMPRESSOR 1.1 RELATED DOCUMENTS PART 1 - GENERAL A. Drawings and general provisions of the Contract, including General

More information

SV418 Series Bronze Safety Valves ASME Section VIII - NB Certified for Air, Gas, Steam, and Liquid

SV418 Series Bronze Safety Valves ASME Section VIII - NB Certified for Air, Gas, Steam, and Liquid Safety SV418 Series Bronze Safety Description Spirax Sarco's SV418 safety and relief valve is designed for accuracy and reliability. Engineered for heavy-duty industrial usage. Multiple purpose safety

More information

5.0 REACTOR COOLANT SYSTEM AND CONNECTED SYSTEMS

5.0 REACTOR COOLANT SYSTEM AND CONNECTED SYSTEMS Summary Description 5.0 REACTOR COOLANT SYSTEM AND CONNECTED SYSTEMS This chapter of the U.S. EPR Final Safety Analysis Report (FSAR) is incorporated by reference with supplements as identified in the

More information

4.1 Type of the valve and materials of construction of body and trim shall be as specified in valve Data sheet.

4.1 Type of the valve and materials of construction of body and trim shall be as specified in valve Data sheet. SHEET 1 OF 5 1.0 GENERAL & SCOPE 1.1 This specification covers the design, material, construction features, manufacture, inspection & testing, Painting and packing requirements of Spring Loaded Bypass

More information

Driver Operator Aerials: Maintenance and Testing. 4 Skills Total. NFPA 1002, Standard for Driver Operator Professional Qualifications, 2014 Edition

Driver Operator Aerials: Maintenance and Testing. 4 Skills Total. NFPA 1002, Standard for Driver Operator Professional Qualifications, 2014 Edition Driver Operator Aerials: Maintenance and Testing 4 Skills Total NFPA 1002, Standard for Driver Operator Professional Qualifications, 2014 Edition Driver Operator Aerials Maintenance & Testing Skills Book

More information

THIS BULLETIN MODIFIES THE A4A BULLETIN , DATED DECEMBER 11, 2017

THIS BULLETIN MODIFIES THE A4A BULLETIN , DATED DECEMBER 11, 2017 Bulletin 2018.1 Update on ATA103 Requirements June 5, 2018 THIS BULLETIN MODIFIES THE A4A BULLETIN 2017.2, DATED DECEMBER 11, 2017 Based on feedback from the industry, A4A is modifying the deadlines for

More information

* Contact your sales representative for compliance to NACE MR or later requirements.

* Contact your sales representative for compliance to NACE MR or later requirements. VALVES & CONTROLS crosby SERIES 00, 00 OMNI-TRIM, AND BP OMNI-TRIM Crosby s Series 00 adjustable blowdown, Series 00 fixed blowdown OMNI-TRIM, and BP OMNI-TRIM full nozzle pressure relief valves have a

More information

Have your Vehicle Converted to Compressed Natural Gas - SAFELY

Have your Vehicle Converted to Compressed Natural Gas - SAFELY Have your Vehicle Converted to Compressed Natural Gas - SAFELY Once you decide to convert your existing vehicle to compressed natural gas (CNG) or buy a vehicle that has already been converted to run on

More information

Aoý. 0Constellation Nuclear. Calvert Cliffs Nuclear Power Plant. February 27, U. S. Nuclear Regulatory Commission Washington, DC 20555

Aoý. 0Constellation Nuclear. Calvert Cliffs Nuclear Power Plant. February 27, U. S. Nuclear Regulatory Commission Washington, DC 20555 Charles H. Cruse Vice President Nuclear Energy 1650 Calvert Cliffs Parkway Lusby, Maryland 20657 410 495-4455 0Constellation Nuclear Calvert Cliffs Nuclear Power Plant A Member of the Constellation Energy

More information

Installation and Maintenance Manual CEMLINE CORPORATION

Installation and Maintenance Manual CEMLINE CORPORATION $5.00 Installation and Maintenance Manual CEMLINE CORPORATION STONESTEEL Tanks Horizontal STONESTEEL Tanks Vertical STONESTEEL Tanks CEMLINE CORPORATION P. O. Box 55, Cheswick, PA, 15024 Phone: (724) 274-5430

More information

Installation and Maintenance Manual CEMLINE CORPORATION

Installation and Maintenance Manual CEMLINE CORPORATION $5.00 Installation and Maintenance Manual CEMLINE CORPORATION Steel Tanks Horizontal Steel Tanks Vertical Steel Tanks CEMLINE CORPORATION P. O. Box 55, Cheswick, PA, 15024 Phone: (724) 274-5430 FAX (724)

More information

304C. Valve Group. Series Farris Engineering Pressure Relief Valves

304C. Valve Group. Series Farris Engineering Pressure Relief Valves 304C Valve Group Series 600 Farris Engineering Pressure Relief Valves Type Numbering System Our type numbering system simplifies the selection and specifying of Farris pressure relief valves because the

More information

PFI Quality Assurance/Quality Control (QA/QC) Program for Residential/Commercial Densified Fuels

PFI Quality Assurance/Quality Control (QA/QC) Program for Residential/Commercial Densified Fuels PFI Quality Assurance/Quality Control (QA/QC) Program for Residential/Commercial Densified Fuels Scope: This program must be utilized by participating pellet fuel manufacturers to assure consistent quality

More information

ASME Section I and VIII - NB Certified for Air/Gas and Steam. Series 560. Series 570. Series Stainless steel whetted trimming.

ASME Section I and VIII - NB Certified for Air/Gas and Steam. Series 560. Series 570. Series Stainless steel whetted trimming. SAFETY VALVES Safety Valves SIZES FROM 1/2 TO 2 1/2 RATED TO 300 PSI TEMPERATURES TO 450 F ASME Section I and VIII - NB Certified for Air/Gas and Steam Aquatrol s Series / valve line is a high capacity

More information

June 22, 2017 Nashville, TN

June 22, 2017 Nashville, TN June 22, 2017 Nashville, TN Cargo Tank Issues Federal Motor Carrier Safety Administration 1 Topics Regulated Industry and FMCSA Mission Investigations and Safety Alerts Top 20 Cargo Tank Facility Violations

More information

NCC Leisure Battery Verification Scheme. Leisure Accommodation Vehicles

NCC Leisure Battery Verification Scheme. Leisure Accommodation Vehicles The UK trade body for the caravan, motorhome, caravan holiday and park home industry. NCC Leisure Battery Verification Scheme Leisure Accommodation Vehicles Page 1 of 11 1 Scope The NCC Battery Verification

More information

TYPE PC Propeller Condensate Pumps

TYPE PC Propeller Condensate Pumps SHIPPENSBURG PUMP CO. INC. P.O. BOX 279, SHIPPENSBURG, PA 17257 PH 717-532-7321 FAX 717-532-7704 WWW.SHIPCOPUMPS.COM BULLETIN 103 Revised 8/17 TYPE PC Propeller Condensate Pumps with Cast Iron Receivers

More information

1541/1543 Series. Consolidated * Valves. Safety Valve

1541/1543 Series. Consolidated * Valves. Safety Valve GE Oil & Gas Technical Specifications 11/2014 Consolidated * Valves 1541/1543 Series Safety Valve Designed for steam and other compressible fluids, these valves are most commonly used in pharmaceutical,

More information

MERCER VALVE GENERAL INFORMATION THINK...MERCER FIRST MERCER VALVE CO., INC. AUTO SEAT TECHNOLOGY

MERCER VALVE GENERAL INFORMATION THINK...MERCER FIRST MERCER VALVE CO., INC. AUTO SEAT TECHNOLOGY MERCER VALVE CO., INC. AUTO SEAT TECHNOLOGY GENERAL INFORMATION MERCER VALVE THINK...MERCER FIRST Mercer Valve Company Mercer Valve Company, Inc. was founded by Wesley Taylor with his patented design for

More information

MSC Guidelines for Fired Thermal Fluid Heaters Procedure Number: E1-28 Revision Date: 06/11/2014

MSC Guidelines for Fired Thermal Fluid Heaters Procedure Number: E1-28 Revision Date: 06/11/2014 References P. W. Gooding, Chief of Engineering Division a. 46 CFR Part 52 Power Boilers b. 46 CFR Part 54 Pressure Vessels c. 46 CFR Part 63 Automatic Auxiliary Boilers Contact Information If you have

More information

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL INSTALLATION, OPERATION AND MAINTENANCE MANUAL SAFETY RELIEF VALVES Revision: 30 June 2004 TOSACA,S.A. INSTALLATION, OPERATION AND MAINTENANCE MANUAL June-04 pag.1 TABLE OF CONTENTS 1. General 2. Description

More information

Pressure Relief Valves. 1541/1543 Series. Consolidated Safety Valve

Pressure Relief Valves. 1541/1543 Series. Consolidated Safety Valve Pressure Relief Valves 1541/1543 Series Consolidated Safety Valve Table of Contents Conversion Table 1541/1543.2 Features & Benefits 1541/1543.3 Applications 1541/1543.3 Scope of Design 1541/1543.4 Materials

More information

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY SECTION 230533 - PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pressure gages. 2. Pressure gage taps. 3. Thermometers. 4. Thermometer supports. 5. Test plugs. 6. Static pressure

More information

E/ECE/324/Rev.2/Add.102/Rev.1 E/ECE/TRANS/505/Rev.2/Add.102/Rev.1

E/ECE/324/Rev.2/Add.102/Rev.1 E/ECE/TRANS/505/Rev.2/Add.102/Rev.1 30 August 2011 Agreement Concerning the adoption of uniform technical prescriptions for wheeled vehicles, equipment and parts which can be fitted and/or be used on wheeled vehicles and the conditions for

More information

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE TYPE APPROVAL CERTIFICATE Certificate No: TAP00000K7 Revision No: 1 This is to certify: That the Safety Valve with type designation(s) Safety valves with bellow seal, Types: 06800, 06801, 06805, 06806

More information

RESOLUTION MEPC.205(62) Adopted on 15 July GUIDELINES AND SPECIFICATIONS FOR ADD-ON EQUIPMENT FOR UPGRADING RESOLUTION

RESOLUTION MEPC.205(62) Adopted on 15 July GUIDELINES AND SPECIFICATIONS FOR ADD-ON EQUIPMENT FOR UPGRADING RESOLUTION MEPC.60(33)-COMPLIANT OIL FILTERING EQUIPMENT MEPC.60(33)-COMPLIANT OIL FILTERING EQUIPMENT MEPC 62/24/Add.1 Annex 24, page 1 ANNEX 24 RESOLUTION MEPC.205(62) 2011 GUIDELINES AND SPECIFICATIONS FOR ADD-ON

More information

BUREAU OF STANDARDS. Effective Date: 8/19/2016 Section No. 4. Version: 1.2 Procedure No. 3

BUREAU OF STANDARDS. Effective Date: 8/19/2016 Section No. 4. Version: 1.2 Procedure No. 3 BUREAU OF STANDARDS Effective Date: 8/19/2016 Section No. 4 Version: 1.2 Procedure No. 3 TITLE: LP Gas Bulk Plant Final Inspection PURPOSE: This document details the procedures used to conduct a Final

More information

DIVISION 311 MISCELLANEOUS ELECTRICAL RULES

DIVISION 311 MISCELLANEOUS ELECTRICAL RULES DIVISION 311 MISCELLANEOUS ELECTRICAL RULES 918-311-0000 Design, Planning and Lay Out of Electrical Installations by Supervising Electricians A licensed supervising electrician may design, plan and lay

More information

Table of Contents. 1900/P3 Series Exposed spring design - The spring in this design is exposed for atmospheric cooling. D through T orifice sizes.

Table of Contents. 1900/P3 Series Exposed spring design - The spring in this design is exposed for atmospheric cooling. D through T orifice sizes. Scope of Design Table of Contents Scope of Design...............................................................1900P.1 Materials 1900/P1 (Conventional)......................................................1900P.3

More information

PORSCHE CLUB OF AMERICA - INLAND NORTHWEST REGION. OWNER and Declaration

PORSCHE CLUB OF AMERICA - INLAND NORTHWEST REGION. OWNER and Declaration PORSCHE CLUB OF AMERICA - INLAND NORTHWEST REGION Driver Education Technical Inspection Program Pre-Event Inspection Welcome to our 2018 Driving Season. This inspection shall be completed within 30 days

More information

SFI SPECIFICATION 15.2 EFFECTIVE: MAY 1, 2008 *

SFI SPECIFICATION 15.2 EFFECTIVE: MAY 1, 2008 * SFI SPECIFICATION 15.2 EFFECTIVE: MAY 1, 2008 * PRODUCT: Drag Race Front Wheels 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes uniform test procedures and minimum standards for evaluating

More information

Anderson Greenwood Series 5100 Pilot Operated Pressure Relief Valves

Anderson Greenwood Series 5100 Pilot Operated Pressure Relief Valves ANDERSON GREENWOOD Series 5100 Modulating Safety Relief Valve Anderson Greenwood has developed the revolutionary Series 5100 specifically to serve Economizer applications requiring pressure relief under

More information

NORTH AMERICAN STANDARDS FOR LOW-VOLTAGE FUSES

NORTH AMERICAN STANDARDS FOR LOW-VOLTAGE FUSES 127 NORTH AMERICAN STANDARDS FOR LOW-VOLTAGE FUSES Dale A. Hallerberg, P.E. Underwriters Laboratories Inc. September 25, 1995 1 General 1.1 Abstract The ability of fuse manufacturers to access larger markets

More information

ENGINEERING MANUAL PRESSURE STEAM HUMIDIFIERS

ENGINEERING MANUAL PRESSURE STEAM HUMIDIFIERS Ogdensburg, New York, U.S.A. 1-866-NORTEC-1 Ottawa, Ontario, Canada 1-866-NORTEC-1 ENGINEERING MANUAL PRESSURE STEAM HUMIDIFIERS The LS Series is a cost effective way to provide precise humidity control,

More information

KINGSTON. KNG Series Product Catalog. Ph: Toll:

KINGSTON. KNG Series Product Catalog. Ph: Toll: KEst.1908 KINGSTON KNG Product Catalog Storm Manufacturing Group, Inc. 23201 Normandie Ave., Torrance, CA 90501-5050 Ph: 310.326.8287 Toll: 800.210.2525 Email: sales@kingstonvalves.com Kingston Safety

More information

CROSBY SERIES BP OMNI-TRIM PRESSURE RELIEF VALVES INSTALLATION, MAINTENANCE AND ADJUSTMENT INSTRUCTIONS

CROSBY SERIES BP OMNI-TRIM PRESSURE RELIEF VALVES INSTALLATION, MAINTENANCE AND ADJUSTMENT INSTRUCTIONS Before installation these instructions must be read fully and understood cause misalignment of the valve parts. It is recommended that the valves be left in their original shipping containers and that

More information

Installation and Operation Manual

Installation and Operation Manual Industrial Process Installation and Operation Manual Advantage Actuator 2.0 Table of Contents Table of Contents Introduction and Safety...2 Safety message levels...2 User health and safety...2 Transportation

More information

5.1 Design and Install Dispenser Transfer Systems Performance Based Skill Assessments 2019

5.1 Design and Install Dispenser Transfer Systems Performance Based Skill Assessments 2019 5.1 Design and Install Dispenser Transfer Systems Performance Based Skill Assessments 2019 Section One: Task 1 Task 2 Task 3 Task 4 Task 5 Task 6 Task 7 Task 8 Design Dispenser Transfer System Determine

More information

Crosby Series BP OMNI-TRIM Pressure Relief Valves for applications involving variable back pressure.

Crosby Series BP OMNI-TRIM Pressure Relief Valves for applications involving variable back pressure. CROSBY Crosby Series BP OMNI-TRIM Pressure Relief Valves for applications involving variable back pressure. Features The balanced piston design offsets the effects of variable back pressure on valve set

More information

C.A.S.E. Air Carrier Section Policies & Procedures

C.A.S.E. Air Carrier Section Policies & Procedures Audit Date: Station Code: City: Vendor Name: Address: INTO-PLANE CHECKLIST Primary Contact: Title: Phone: Fax: Auditor: Acceptable: Conditionally Acceptable Not Acceptable Register: (Circle One) Add Delete

More information

ANDERSON GREENWOOD SERIES 500 PILOT OPERATED SAFETY RELIEF VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

ANDERSON GREENWOOD SERIES 500 PILOT OPERATED SAFETY RELIEF VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS Before installation these instructions must be fully read and understood TABLE OF CONTENTS 1. General valve description and start-up... 1 2. Main valve maintenance... 1 3. Pilot maintenance... 5 4. Pilot

More information

Section 12: Record Keeping Requirements. Minnesota Trucking Regulations

Section 12: Record Keeping Requirements. Minnesota Trucking Regulations Section 12: Record Keeping Requirements Minnesota Trucking Regulations 89 Section 12 Record Keeping Requirements 49 CFR Part 390 Motor carriers who are subject to the Federal Motor Carrier Safety Regulations

More information

BIG BLASTER XHV Air Cannon Retrofit with MARTIN TORNADO Exhaust Valve

BIG BLASTER XHV Air Cannon Retrofit with MARTIN TORNADO Exhaust Valve BIG BLASTER XHV Air Cannon Retrofit with MARTIN TORNADO Exhaust Valve Go to BIG BLASTER XHV Air Cannon Retrofit with MARTIN TORNADO Exhaust Valve web page MARTIN TORNADO Exhaust Valves Retrofit Internal

More information

CHAPTER 20.1 WASTEWATER HAULING. Section Definitions. For the purposes of this article, the following definitions shall apply:

CHAPTER 20.1 WASTEWATER HAULING. Section Definitions. For the purposes of this article, the following definitions shall apply: CHAPTER 20.1 WASTEWATER HAULING Section 20.1-1. Definitions. For the purposes of this article, the following definitions shall apply: Commercial wastewater shall mean the liquid or liquid-borne wastes

More information

13900 Series. Consolidated * Valves. Pilot-Operated Safety Relief Valve

13900 Series. Consolidated * Valves. Pilot-Operated Safety Relief Valve GE Oil & Gas Technical Specifications 08/2014 Consolidated * Valves 13900 Series Pilot-Operated Safety Relief Valve Designed specifically for high capacity steam applications, this series of valves contributes

More information

Requirements for Alteration Design Registration Based on Fitness-for-Service

Requirements for Alteration Design Registration Based on Fitness-for-Service the pressure equipment safety authority Requirements for Based on Fitness-for-Service AB 535 Edition 1, Revision 0 - Issued 2018-06-27 Table of Contents FOREWORD... ii 1.0 INTRODUCTION... 1 2.0 DEFINITIONS

More information

Vehicle Maintenance and Management Program The company focuses on the process as much as the outcome

Vehicle Maintenance and Management Program The company focuses on the process as much as the outcome Full Circle Transportation Group LLC Vehicle Maintenance and Management Program The company focuses on the process as much as the outcome LAS VEGAS, NEVADA www.fctg.org FCTG COMPANY PROFILE DOT 2379319

More information

ZAP * & KBA Reverse Acting Rupture Discs

ZAP * & KBA Reverse Acting Rupture Discs ZAP * & KBA Reverse Acting Rupture Discs 3-2220-3 ZAP and KBA Rupture Discs The ZAP and KBA reverse acting rupture discs utilize knife blades to open the rupture discs as reversal occurs. The rupture discs

More information

What s New With The Gold Standard:

What s New With The Gold Standard: What s New With The Gold Standard: NEW XTREME PERFORMANCE LINE! 2-Piece Xtreme Relief Valves for broad temperature ranges (-400 F to 400 F) and broad chemical compatibility. NEW LOW CAPACITY VALVE! 800

More information

EU RO Mutual Recognition Technical Requirements

EU RO Mutual Recognition Technical Requirements 1. PRODUCT DESCRIPTION... 1 2. DESIGN EVALUATION... 2 3. PRODUCTION REQUIREMENTS... 5 4. MARKING REQUIREMENTS... 6 5. TYPE APPROVAL CERTIFICATE CONTENT... 6 6. APPROVAL DATE AND REVISION NUMBER... 6 7.

More information

Pre-Trip or Interim Inspection of Heritage Steam Locomotives

Pre-Trip or Interim Inspection of Heritage Steam Locomotives Page 1 of 5 Pre-Trip or Interim Inspection of Heritage Steam Locomotives Date of Inspection / / Vehicle ID Operator Inspected at This Vehicle is fit to operate run on the National Rail System with the

More information

*Attachment A 1 SCOPE 1.1 This Standard covers cast copper alloy: (a) threaded pipe flanges and blind flanges having rating class designations 150, 300, 600, 900, 1500, and 2500, (b) flanged fittings having

More information

Series Low Pressure Steam Boiler Safety Valves

Series Low Pressure Steam Boiler Safety Valves 14-200 Series Low Pressure Steam Boiler Safety Valves ASME Section IV Set pressures from 5 to 15. Sizes 2", 2-1/2" and 3". Section IV Heating Boilers Applications: The 14 Series is an ASME Section IV high

More information

Improving Valve Fugitive Emissions Performance

Improving Valve Fugitive Emissions Performance Improving Valve Fugitive Emissions Performance Steve McJones and Rich Sobilo March 6, 2014 Steve McJones Advisor Pressure Vessels, Piping and Valves BP Refining & Logistics Technology Support BP Refineries

More information

Requirements for Dispensing of Compressed Natural Gas. Yvonne Espinoza, PE Austin Fire Department Engineering Services

Requirements for Dispensing of Compressed Natural Gas. Yvonne Espinoza, PE Austin Fire Department Engineering Services Requirements for Dispensing of Compressed Natural Gas Yvonne Espinoza, PE Austin Fire Department Engineering Services Course Overview Enforcement of code requirements Application of code requirements Hazard

More information

QUALITY REQUIREMENTS FOR JUST IN TIME SERVICE PROVIDER (JIT S.P.) PROGRAM: ALL

QUALITY REQUIREMENTS FOR JUST IN TIME SERVICE PROVIDER (JIT S.P.) PROGRAM: ALL QUALITY REQUIREMENTS FOR JUST IN TIME SERVICE PROVIDER (JIT S.P.) PROGRAM: ALL THE CONTENT OF THIS DOCUMENT IS THE PROPERTY OF ALENIA AERONAUTICA S.p.A. THIS DOCUMENT IS SUPPLIED IN CONFIDENCE AND COMMERCIAL

More information

CHAPTER 25. SUBSTANTIVE RULES APPLICABLE TO ELECTRIC SERVICE PROVIDERS.

CHAPTER 25. SUBSTANTIVE RULES APPLICABLE TO ELECTRIC SERVICE PROVIDERS. 25.211. Interconnection of On-Site Distributed Generation (DG). (a) (b) (c) Application. Unless the context indicates otherwise, this section and 25.212 of this title (relating to Technical Requirements

More information

AIIPA Standardized Best Practices Recommendations

AIIPA Standardized Best Practices Recommendations AIIPA Standardized Best Practices Recommendations AIIPA recognizes that BAIIDS programs differ from state or jurisdictions for a variety of reasons. Differences will be found in regard to legal issues

More information

DRIVER QUALIFICATION FILE CHECKLIST

DRIVER QUALIFICATION FILE CHECKLIST DRIVER QUALIFICATION FILE CHECKLIST 1. DRIVER APPLICATION FOR EMPLOYMENT 391.21 2. INQUIRY TO PREVIOUS EMPLOYERS (3 YEARS) 391.23(a)(2) & (c) 3. INQUIRY TO STATE AGENCIES 391.23(a)(1) & (b) 4. MEDICAL

More information

E/ECE/324/Rev.2/Add.108/Rev.1/Amend.3 E/ECE/TRANS/505/Rev.2/Add.108/Rev.1/Amend.3

E/ECE/324/Rev.2/Add.108/Rev.1/Amend.3 E/ECE/TRANS/505/Rev.2/Add.108/Rev.1/Amend.3 16 January 2019 Agreement Concerning the Adoption of Harmonized Technical United Nations Regulations for Wheeled Vehicles, Equipment and Parts which can be Fitted and/or be Used on Wheeled Vehicles and

More information

Gas Lift Valves Barrier Testing

Gas Lift Valves Barrier Testing Gas Lift Valves Barrier Testing Sven Aarrestad, IRIS Jørn Andre Carlsen, Statoil Statoil & IRIS* In 1982 Statoil introduced a qualification testing program for Down Hole Safety Valves This was the start

More information

Navigating Safety and Compliance in Registration is now open online for the 2018 Idealease/NPTC Safety Seminars!

Navigating Safety and Compliance in Registration is now open online for the 2018 Idealease/NPTC Safety Seminars! In This Issue: Navigating Safety and Compliance in 2018 Registration is now open on line for the 2018 Idealease/NPTC Safety Seminars! Seminar Schedule Are You Sharing Your Driver With Another Company?

More information

SAFETY AND COMPLIANCE TESTING FOR SURESTOP

SAFETY AND COMPLIANCE TESTING FOR SURESTOP SAFETY AND COMPLIANCE TESTING FOR SURESTOP Tested Sample(s) Brand Model Color Size Vendor P/N Country of Origin Age Grading Children s Product : Bicycle Brake Pads : SureStop : SureStop Brakes Prepared

More information

New Ulm Public Utilities. Interconnection Process and Requirements For Qualifying Facilities (0-40 kw) New Ulm Public Utilities

New Ulm Public Utilities. Interconnection Process and Requirements For Qualifying Facilities (0-40 kw) New Ulm Public Utilities New Ulm Public Utilities Interconnection Process and Requirements For Qualifying Facilities (0-40 kw) New Ulm Public Utilities INDEX Document Review and History... 2 Definitions... 3 Overview... 3 Application

More information

Martin Tornado Retrofit Valve

Martin Tornado Retrofit Valve Martin Tornado Retrofit Valve Go to Martin Tornado Retrofit Valve web page Martin Tornado Retrofit Valves Retrofit Internal and External Valve Air Cannons Internal Valve Air Cannon External Valve Air Cannon

More information

Meeting of January 14, 2014 San Antonio, Texas

Meeting of January 14, 2014 San Antonio, Texas Date Distributed: December 23, 2013 SUBGROUP ON INSPECTION SPECIFIC Meeting of January 14, 2014 San Antonio, Texas AGENDA The National Board of Boiler & Pressure Vessel Inspectors 1055 Crupper Avenue Columbus,

More information

SAFETY relief VALVE SERIES # 006 DESIGN FEATURES HARSHAD ENGINEERING WORKS HARSHAD ENGINEERING WORKS TECHNICAL DATA : ISO 9001 CERTIFIED COMPANY

SAFETY relief VALVE SERIES # 006 DESIGN FEATURES HARSHAD ENGINEERING WORKS HARSHAD ENGINEERING WORKS TECHNICAL DATA : ISO 9001 CERTIFIED COMPANY PROVIDES HIGH QUALITY OVERPRESSURE PROTECTION FOR AIR, GAS, LIQUID & STEAM IN SINGLE STANDARDIZED DESIGN SAFETY relief VALVE DESIGN FEATURES SAFETY VALVE MANUFACTURED IN ACCORDANCE WITH REQUIREMENT OF

More information

Crosby Style JQ pressure relief device

Crosby Style JQ pressure relief device A combination pressure relief device designed with internal parts completely isolated from corrosive fluids and environments Features Designed in collaboration with the Chlorine Institute, Inc. Provides

More information

CLOSURE DIMENSIONS SIZES 6-12 CLASS 150/900TV VERTICAL WITH HINGE SIZES 6-12 CLASS 150/900TH HORIZONTAL WITH HINGE

CLOSURE DIMENSIONS SIZES 6-12 CLASS 150/900TV VERTICAL WITH HINGE SIZES 6-12 CLASS 150/900TH HORIZONTAL WITH HINGE T-Closure catalog 8/11/03 11:51 PM Page 1 CLOSURE DIMENSIONS SIZES 6-12 CLASS 150/900TV VERTICAL WITH HINGE Size A B C D E F Weight In (DN) In (cm) In (cm) In (cm) In (cm) In (cm) In (cm) Lbs (Kg) 6 (150)

More information

PLS Boiler Inspection Standard Introduction

PLS Boiler Inspection Standard Introduction Introduction Boilers are complex devices that, in operation, contain large quantities of energy. Sudden release of this energy can cause property damage and serious injury. In the early days of steam railroading

More information

CITY OF NEWPORT NEWS - WATERWORKS APPLICATION FOR HYDRANT METER ASSEMBLY & SERVICE PERMIT

CITY OF NEWPORT NEWS - WATERWORKS APPLICATION FOR HYDRANT METER ASSEMBLY & SERVICE PERMIT CITY OF NEWPORT NEWS - WATERWORKS APPLICATION FOR HYDRANT METER ASSEMBLY & SERVICE PERMIT A Hydrant Meter Assembly (HMA) and Hydrant Meter Service Permit will be issued for water service not intended for

More information

Passenger Train Brake Inspection and Safety Rules: Guidelines for British Columbia s Heritage Railways

Passenger Train Brake Inspection and Safety Rules: Guidelines for British Columbia s Heritage Railways Passenger Train Brake Inspection and Safety Rules: Guidelines for British Columbia s Heritage Railways Part I: General 1. SHORT TITLE 1.1 For ease of reference, these rules may be referred to as the "Train

More information

1 Clearheart Construction Co., Inc. Mobile Crane - Onshore MOBILE CRANES Cranes and derricks

1 Clearheart Construction Co., Inc. Mobile Crane - Onshore MOBILE CRANES Cranes and derricks Mobile Crane - Onshore MOBILE CRANES Cranes and derricks. - 1926.550 Cranes, like all pieces of heavy equipment, if not properly operated, inspected and maintained have a potential for causing major bodily

More information

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM

American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM American Society of Sanitary Engineering PRODUCT (SEAL) LISTING PROGRAM ASSE STANDARD #1012 - REVISED: 2009 Backflow Preventers with an Intermediate Atmospheric Vent Separate, complete laboratory evaluation

More information

Anderson Greenwood Series 400 Piston Pilot POPRV Installation and Maintenance Instructions

Anderson Greenwood Series 400 Piston Pilot POPRV Installation and Maintenance Instructions Before installation these instructions must be fully read and understood As capacity relief of the system is satisfied, system pressure will begin to decrease. When it does, the pilot will actuate and

More information

Certification Memorandum. Approved Model List Changes

Certification Memorandum. Approved Model List Changes Certification Memorandum Approved Model List Changes EASA CM No.: CM 21.A-E Issue 01 issued 15 August 2018 Regulatory requirement(s): 21.A.57, 21.A.61, 21.A.62, 21.A.91, 21.A.93, 21.A.97, 21.A.114, 21.A.117,

More information

Series Safety Valves for ASME Section I and VIII Boiler Applications 1005C

Series Safety Valves for ASME Section I and VIII Boiler Applications 1005C Series 4200 Safety Valves for ASME Section I and VIII Boiler Applications 1005C Table of Contents Introduction & Warranty...IFC Numbering System & Ordering Information...1 Features & Benefits...2 Bill

More information

Crosby Style JQ Pressure Relief Device. Flow Control

Crosby Style JQ Pressure Relief Device. Flow Control Designed in collaboration with the, Inc. the Crosby JQ is designed with internal parts completely isolated from corrosive fluids and environments. The Crosby Style JQ pressure relief device was designed

More information

Series Safety Valves for ASME Section I and VIII Boiler Applications 1005C

Series Safety Valves for ASME Section I and VIII Boiler Applications 1005C Series 4200 Safety Valves for ASME Section I and VIII Boiler Applications 1005C Table of Contents Introduction & Warranty...IFC Numbering System & Ordering Information...1 Features & Benefits...2 Bill

More information