THERMAL SHOCK TEST REPORT
|
|
- Willis McCormick
- 6 years ago
- Views:
Transcription
1 Report No. :DH A Version:A THERMAL SHOCK TEST REPORT Company :FLIP CHIP OPTO. INC. Address :No.185, Kewang Rd., Longtan Dist., Taoyuan City 325, Taiwan (R.O.C.) Model Name :Apollo 600-B Lot Number :No.1, No.2, No.3 Date Received :OCT 01, 2015 Date Tested :NOV 24, 2015 TESTING LABORATORY IS ACCREDITED BY: ISO accredited in respect of laboratory is approved by TAF Certificate No.:L ISTA certified laboratory (ID: ST-9389) WE HEREBY CERTIFY THAT: The test(s) shown in the attachment were conducted according to the indicating procedures. We assume full responsibility for the accuracy and completeness of these tests and vouch for the qualifications of all personnel performing them. Name Signature Date Test Engineer Nancy Chang Dec 01, 2015 Manager General Lee Dec 01, 2015 NOTE: 1. This report will be invalid if reproduced in part or altered in any way. 2. This report refers only to the specimen(s) submitted to test, and is invalid if used otherwise. 3. This report is ONLY valid with the examination seal and signature of this institute. 4. The tested specimen(s) will only be preserved for thirty days from the date issued, if not collected by the applicant.
2 Reliability Engineering Group Page 1 of 10 TABLE OF CONTENTS 1. GENERAL INFORMATION 1.1 DESCRIPTION OF UNIT THERMAL SHOCK TEST 2.1 TEST EQUIPMENT LABORATORY AMBIENCE CONDITION REFERENCE DOCUMENT TEST CONDITION SUMMARY OF TEST... 3 ATTACHMENTS... 4
3 Reliability Engineering Group Page 2 of GENERAL INFORMATION 1.1 DESCRIPTION OF UNIT Manufacturer:FLIP CHIP OPTO. INC. Model name: Apollo 600-B Lot number:no.1, No.2, No.3 Sample quantity:each lot 1 piece, total of 3 pieces
4 Reliability Engineering Group Page 3 of TEMPERATURE CYCLING TEST 2.1 TEST EQUIPMENT Model Serial Number Calibration Date ESPEC TPC-222M APR14, LABORATORY AMBIENCE CONDITION Temperature:25 C ± 5 C Relative humidity:55 % ± 15 % (RH) 2.3 REFERENCE DOCUMENT The test is based on customer specification 2.4 TEST CONDITION Temperature range:-40 C to +125 C Duration of exposure:15 minutes exposure at each temperature extreme Transfer time:10 seconds Number of cycles:1000 cycles 2.5 SUMMARY OF TEST Visual inspection of sample surfaces showed no abnormity. Functional check is performed by customer.
5 Reliability Engineering Group Page 4 of 10 Attachment 1:Photo of setup Test equipment Setup
6 Reliability Engineering Group Page 5 of 10 Attachment 2:Photo of units before and after test No.1 0 cycle 100 cycles 200 cycles 300 cycles 400 cycles 500 cycles
7 Reliability Engineering Group Page 6 of 10 No cycle 700 cycles 800 cycles 900 cycles 1000 cycles Blank
8 Reliability Engineering Group Page 7 of 10 No.2 0 cycle 100 cycles 200 cycles 300 cycles 400 cycles 500 cycles
9 Reliability Engineering Group Page 8 of 10 No cycle 700 cycles 800 cycles 900 cycles 1000 cycles Blank
10 Reliability Engineering Group Page 9 of 10 No.3 0 cycle 100 cycles 200 cycles 300 cycles 400 cycles 500 cycles
11 Reliability Engineering Group Page 10 of 10 No cycle 700 cycles 800 cycles 900 cycles 1000 cycles Blank << The Following Blank >>
CONTINUOUS IMMERSION AND DUST TEST REPORT
Report No. :HS1404020081A Version:A CONTINUOUS IMMERSION AND DUST TEST REPORT Company Address :Taiway Electronics Components Co. :4F., No. 4, 6, 8, Lane 359, Sec. 2, Zhongshan Rd., Zhonghe Dist., New Taipei
More informationVIBRATION AND MECHANICAL SHOCK TEST REPORT
Report No. :DH1701190024A-1 Version:A VIBRATION AND MECHANICAL SHOCK TEST REPORT Company :OTO Photonics Inc. Address :9F-5,No. 27, Guanxin Rd., East Dist., Hsinchu City 30072, Taiwan(R.O.C.) Sample Name
More informationVIBRATION TEST REPORT
Report No. :HS1505160024A-1 Version:B VIBRATION TEST REPORT Company Address :Cincon Electronics Co., Ltd. :No.8-1 Fu Kung Rd., Fu Hsing ind. Park, Fu Hsing Hsiang, Chang Hua Hsien, Taiwan, R.O.C. Model
More informationSHOCK TEST REPORT. :Cincon Electronics Co., Ltd. Hua Hsien, Taiwan, R.O.C. :EC7BW-110S15, ECLB40W-110S05, CQB60W-110S24
Report No. :HS1505160024A-2 Version:B SHOCK TEST REPORT Company Address :Cincon Electronics Co., Ltd. :No.8-1 Fu Kung Rd., Fu Hsing ind. Park, Fu Hsing Hsiang, Chang Hua Hsien, Taiwan, R.O.C. Model Name
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 DEKRA IST RELIABILITY SEVICES INC. No. 22 Puding Rd., East Dist. Hsinchu City 300, Taiwan, R.O.C. Phone: 886 3 579 5766 ext 7100 Mr. General Lee general.lee@dekra-ist.com
More informationMEASUREMENT AND TEST REPORT
IES LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT For Guangzhou Hongli Opto-Electronic Co., Ltd. West side of Dongfeng Highway, Automobile industrial Base, Huadu
More informationIESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For
IESNA LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT For Guangzhou Hongli Opto-Electronic Co., Ltd. No.1, Xianke Yi Road, Huadong Town, Huadu District, Guangzhou,
More informationSHOCK TEST REPORT. Report No. : ENVA S9 Model Number : S9
Report No. : ENVA10072605 S9 Model Number : S9 Page: 1 of 6 Product Name : S9 Model Number : S9 Date of Receipt : Jul. 26, 2010 Finished date of Test : Jul. 26, 2010 We, Spectrum Research & Testing Laboratory
More informationIES LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES
IES LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT For Guangzhou Hongli Opto-Electronic Co., Ltd. West side of Dongfeng Highway, Automobile industrial Base, Huadu
More informationProduct Change Notice
Product Change Notice Product Change Information: The internal DDR of SQFlash 820 (-S) Series SATA III products will have lithography upgrade from current 42nm to 30nm. The new DDR will be implemented
More informationIESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For
IESNA LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT For SHENZHEN MTC LIGHTING CO., LTD. NO.65,Chuangyi Road,Dalang Street,Baoan District,Shenzhen,GuangDong Province,CHINA
More informationIESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For
IESNA LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT For Fujian Lightning Optoelectronic Co., Ltd.Shenzhen Branch 5F, Building B, second phase of Chuangjian Industrial
More informationIESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For
IESNA LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT For Room 316, Building 2, No.1, Xianke Yi Road, Huadong Town, Huadu District, Guangzhou, China Model:100B10C10(Ra2)
More informationIESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For
IESNA LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT For No.1, Xianke Yi Road, Huadong Town, Huadu District, Guangzhou, China Model:40B18C12(Ra2) Report Type: 10000
More informationFEBRRUARY 22, 2008 TEST REPORT # QSH/QTH/QTE SERIES CONNECTOR SHEAR TESTING SAMTEC, INC.
FEBRRUARY 22, 2008 TEST REPORT #207908 QSH/QTH/QTE SERIES CONNECTOR SHEAR TESTING SAMTEC, INC. APPROVED BY: DOMINIC ARPINO PROGRAM MANAGER CONTECH RESEARCH, INC. Contech Research REVISION HISTORY DATE
More informationSmartSensor 105 & Advance NEMA Salt Fog
SmartSensor 105 & Advance NEMA Salt Fog Test Report Wavetronix products mentioned: SmartSensor 105 SmartSensor Advance As contracted by Wavetronix, Environ Laboratories LLC performed a NEMA salt fog test
More informationHIGH SPEED MEZZANINE PRODUCT SPECIFICATION
OARD TO OARD CONNECTOR 75005 Receptacle Assembly 75003 Plug Assembly Table of Contents 1.0 Scope 2.0 Product Description 3.0 Applicable Documents and Specifications 4.0 Ratings 5.0 Performance 5.1 Qualification
More informationCompliance Certification Services Inc. Report No: MIL(CS101) Date of Issue: August 12, 2009 MIL STD 461E/ F TEST REPORT.
Compliance Certification Services Inc. MIL STD 461E/ F TEST REPORT For 20.1 Multimedia LCD Monitor Model Number: WMRM920-PIP Trade Name: itech Issued to itech Company LLC 41758 Christy Street, Fremont
More informationCertificate of Calibration
Model Number Manufacturer Description Serial Number DSOX2014A Keysight Technologies Inc Oscilloscope, 4-channel, 100MHz MY52161639 Date of Calibration 5 Dec 2014 Procedure STE-50114571-A.02.00 Temperature
More informationASTM Consensus Standards The Latest in Packaging Testing. Presented by: Dhuanne Dodrill President Rollprint Packaging Products, Inc.
ASTM Consensus Standards The Latest in Packaging Testing Presented by: Dhuanne Dodrill President Rollprint Packaging Products, Inc. ASTM Overview Established in 1898 Voluntary, Full-Consensus Standards
More informationBERKELEY ANALYTICAL 815 Harbour Way South, Suite 6 Richmond, CA Ph ; Fax
BERKELEY ANALYTICAL 815 Harbour Way South, Suite 6 Richmond, CA 94804-3614 Ph. 510-236-2325; Fax 510-236-2335 E-mail info@berkeleyanalytical.com Product Sample Formaldehyde Emissions Customer & Building
More informationTest Group Description. Total Number. Figure 1. Unless otherwise stated, the following environmental conditions prevailed during testing:
Qualification Test Report 26 November 12 Rev A1 SL Series Jacks, Category 6 1. INTRODUCTION 1.1. Purpose 1.2. Scope Testing was performed on AMP NETCONNECT* SL Series Category 6 Jacks to determine their
More informationUnited States Stove Company Project # Model: KP60 AKA: AP60, VG60 Type: Pellet-Fired Room Heater May 31, 2018
United States Stove Company Project # 18-409 AKA: AP60, VG60 Type: Pellet-Fired Room Heater May 31, 2018 ASTM E2779 Standard Test Method for Determining Particulate Matter Emissions from Pellet Heaters
More informationAUGUST 28, 2008 TEST REPORT # REV.1.1 MIXED FLOWING GAS TESTING CONNECTOR SERIES CLP S-D-A FTSH S-DV-A SAMTEC, INC.
AUGUST 28, 2008 TEST REPORT #208383-3 REV.1.1 MIXED FLOWING GAS TESTING CONNECTOR SERIES CLP-130-02-S-D-A FTSH-130-02-S-DV-A SAMTEC, INC. APPROVED BY: DOMINIC ARPINO PROGRAM MANAGER CONTECH RESEARCH, INC.
More informationAUGUST 28, 2008 TEST REPORT # REV.1.1 MIXED FLOWING GAS TESTING CONNECTOR SERIES SEM H-D-WT TEM H-D-WT SAMTEC, INC.
AUGUST 28, 2008 TEST REPORT #208383-5 REV.1.1 MIXED FLOWING GAS TESTING CONNECTOR SERIES SEM-125-02-03.0-H-D-WT TEM-125-02-03.0-H-D-WT SAMTEC, INC. APPROVED BY: DOMINIC ARPINO PROGRAM MANAGER CONTECH RESEARCH,
More informationJun06 Rev D
Product Specification High Speed Serial Data 2 Connector 108-1965 27Jun06 Rev D 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the Tyco Electronics High
More informationSPECIFICATION 宏致電子股份有限公司 桃園縣中壢市東園路 13 號. No.13, Dongyuan Rd., Jhongli City, Taoyuan County 320, Taiwan (R.O.C.)
SPECIFICATION 宏致電子股份有限公司 桃園縣中壢市東園路 13 號 No.13, Dongyuan Rd., Jhongli City, Taoyuan County 320, Taiwan (R.O.C.) TEL: +886-3-463-2808 FAX: +886-3-463-1800 SPEC. NO.: PS - 87151-XXX9 REVISION: D PRODUCT NAME:
More information2.0 TEST PROCEDURES AND RESULTS Vibration Test TEST EQUIPMENT AND INSTRUMENTATION QUALITY ASSURANCE PROGRAM 7 ATTACHMENTS
Page No. 2 TABLE OF CONTENTS Page No. 1.0 INTRODUCTION 3 1.1 Scope 3 1.2 References 3 1.3 Test Specimen Description 3 1.4 Summary 3 2.0 TEST PROCEDURES AND RESULTS 4 2.1 Vibration Test 4 3.0 TEST EQUIPMENT
More informationHarris County Tow Truck Permit Application
Harris County Tow Truck Permit Application I request that I be issued a Harris County Wrecker Permit for Law Enforcement tows from Law Enforcement Scenes in the unincorporated areas of Harris County. I
More informationTEST REPORT No. : SHCCM Date : May. 17, 2013 Page: 1 of 5
Page: 1 of 5 IGEPA GROUP GMBH & CO. KG SACHSENFELD 4, 20097 HAMBURG, GERMANY The following sample(s) was/ were submitted and identified on behalf of the client as: Sample Name : MASTER JET S PREMIUM MESH
More informationSPECIFICATION AND PERFORMANCE TABLE OF CONTENT. 1. Scope Reference Documents Material and Components... 2
TABLE OF CONTENT 1. Scope... 2 2. Reference Documents.. 2 3. Material and Components...... 2 4. Design and Construction..... 2 5. Rating.. 2 6. Performance and Test Descriptions. 2 7. Test Requirements
More informationVerification/Report Number(s): HEARTWAY MEDICAL PRODUCTS Co., Ltd. Applicant Name/Address:
Test Verification Of Conformity On the basis of the tests undertaken, the sample(s) of the below product have been found to comply with the essential requirements of the referenced specifications at the
More information1201 North Catalina Ave. #818 Redondo Beach, CA (310) FAX (866) Classification of Air Cleanliness
C E 1201 North Catalina Ave. #818 Redondo Beach, CA 90277 (310) 372-5011 FAX (866) 882-7457 John@ceccertify.com Classification of Air Cleanliness Company Test Specification Date of Certification Corona,
More informationCommercial-in-Confidence Ashton Old Baths Financial Model - Detailed Cashflow
Year 0 1 2 3 4 5 6 7 8 9 10 11 12 13 Oct-16 Nov-16 Dec-16 Jan-17 Feb-17 Mar-17 Apr-17 May-17 Jun-17 Jul-17 Aug-17 Sep-17 Oct-17 2,038 2,922 4,089 4,349 6,256 7,124 8,885 8,885 8,885 8,885 8,885 8,885 9,107
More information600 Amp Surge Arrester
R&D Center 497 Schooley s Mountain Road Hackettstown, NJ 07840-3906 Tele: 908-852-1122 Fax: 908-813-2091 TEST REPORT NUMBER: 379-17-12164 DATE: 4-3-2012 REPORT OF TEST ON 600 Amp Surge Arrester Statements
More informationSerial Attached SCSI (SAS) Connector
Product 108-51053 Specification DR: Stanley Huang 24 Oct 2013 Rev G APVD: Vincent Peng Serial Attached SCSI (SAS) Connector 1.0 SCOPE This specification covers the requirements for product performance,
More informationPage 2 of 23 UNT150420C11
Page 2 of 23 UNT150420C11 United Nations, Recommendations on the Transport of Dangerous Goods, Manual of Test and Criteria (Rev. 5 th, Amendment 2), Section 38.3 Report Reference No.... : Compiled by...
More informationBeamex MB METROLOGY TEMPERATURE BLOCK. Portable temperature dry block delivering bath-level accuracy for industrial applications
Beamex MB METROLOGY TEMPERATURE BLOCK 87 Portable temperature dry block delivering bath-level accuracy for industrial applications Highly accurate temperature dry block 88 Portable temperature dry block
More informationUnited States Stove Company Project # Model: Breckwell SP1000 Type: Pellet-Fired Room Heater July 25, 2018
United States Stove Company Project # 18-415 Model: Breckwell SP1000 Type: Pellet-Fired Room Heater July 25, 2018 ASTM E2779 Standard Test Method for Determining Particulate Matter Emissions from Pellet
More informationCREEP PERFORMANCE TEST REPORT. Rendered to: TREX COMPANY LLC. Seclusions Composite Privacy Fence System TYPE: Composite Fence System
Architectural Testing CREEP PERFORMANCE TEST REPORT Rendered to: TREX COMPANY LLC Seclusions Composite Privacy Fence System TYPE: Composite Fence System Report No.: Report Date: Expiration Date: 130 Derry
More informationPRODUCT SPECIFICATION
of 3 C Section : For the 200222, 2002323, 2002444, 20025, 200252, 200252, 20026, 200262, 200262, 20028, 200283, 200284, 2002822, 2002824, 200283, 2002832, 2002833, 2002834 and 2002835 series parts..0 GENERAL
More informationSFI SPECIFICATION 1.3 EFFECTIVE: MAY 23, 2000 * PRODUCT: Nitro-Methane Drag Race Multiple Disc Clutch Assemblies
SFI SPECIFICATION 1.3 EFFECTIVE: MAY 23, 2000 * PRODUCT: Nitro-Methane Drag Race Multiple Disc Clutch Assemblies 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes uniform test procedures and
More informationTYPE APPROVAL CERTIFICATE
TYPE APPROVAL CERTIFICATE Certificate No: A-14136 File No: 899.60 Job Id: 262.1-018818-1 This is to certify: That the Peripheral Equipment with type designation(s) Ha-VIS econ 2000 series, econ 3000 series
More informationReport of Inspection
P. O. Box 8238 Searcy, AR 72145 866.811.5237 / 501.279.1166 Fax: 501.279.1225 As required by NFPA 1911 19.3: CFS Inspections is accredited to the requirements of ISO/IEC 17020. Report of Inspection SAFET
More informationQSFP Copper Module Direct Attach Cable Assembly &Cage
Qualification Test Report 501-60067 12Mar. 2012 Rev. 1 QSFP Copper Module Direct Attach Cable Assembly& Qualification Test Report QSFP Copper Module Direct Attach Cable Assembly & Tyco Electronics. (Shanghai)
More informationEU RO Mutual Recognition Technical Requirements
1. PRODUCT DESCRIPTION... 1 2. DESIGN EVALUATION... 2 3. PRODUCTION REQUIREMENTS... 6 4. MARKING REQUIREMENTS... 6 5. TYPE APPROVAL CERTIFICATE CONTENT... 7 6. APPROVAL DATE AND REVISION NUMBER... 7 7.
More informationDispensette. Testing Instructions (SOP) 1. Introduction. May 2009
Dispensette Testing Instructions (SOP) May 2009 1. Introduction The standard ISO DIS 8655 describes both the design and the testing of the bottle-top dispenser. The following Testing Instructions describe
More informationJun 20,2014 Rev A
Product Specification 108-115067 Jun 20,2014 Rev A DDR4 DIMM Through-hole Memory Socket 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the TE Connectivity
More informationCustomer Information. Service Engineer s Responsibilities. Agilent Cary 7000 UMS/UMA/Solids Autosampler
Agilent Preventive Maintenance provides factory recommended service for your analytical systems to assure reliable operation and the accuracy of your results. Delivered by highly-trained and certified
More informationAug07 Rev A All Paragraphs Revised
Qualification Test Report Universal MATE-N-LOK* Connector 110-213 28Aug07 Rev A All Paragraphs Revised 1. INTRODUCTION 1.1. Purpose 1.2. Scope Testing was performed on Universal MATE-N-LOK* connectors
More informationMEZALOK* Stacking Connector System
Product Specification 108-2411 25 FEB 16 Rev D MEZALOK* Stacking Connector System 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the MEZALOK* Stacking Connector
More informationSAMTEC POWER CHARACTERIZATION
Project Number: Tracking Code: Power Report Rev 3 Requested by: Eric Mings Date: 9/11/2012 Product Rev: AE Part #: MMSD-25-24-L-12.00-D-K-LUS Lot #: «Lot_Number» Tech: Tony Wagoner Eng: Eric Mings Part
More informationSFI SPECIFICATION 15.2 EFFECTIVE: MAY 1, 2008 *
SFI SPECIFICATION 15.2 EFFECTIVE: MAY 1, 2008 * PRODUCT: Drag Race Front Wheels 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes uniform test procedures and minimum standards for evaluating
More informationSGS TEST REPORT. Page: 1 of 6 Date: April 20, itech Company LLC Christy Street, Fremont CA USA
Page: 1 of 6 Date: April 20, 2010 itech Company LLC 41758 Christy Street, Fremont CA 94538 USA The following merchandise was submitted and identified by the vendor as: Product Description: 20.1 Multimedia
More informationAmendment to Test Report
Test Report issued under the responsibility of www.nemko.com Amendment to Test Report This Amendment is valid only together with the main Test Report Report No.... : 277782 Main Report No.... : 261294
More informationVITLAB Dispenser. Standard Operating Procedure (SOP)
VITLAB Dispenser Standard Operating Procedure (SOP) VITLAB GmbH Linus-Pauling-Str. 63762 Grossostheim Germany tel: +49 6026 97799-0 fax: +49 6026 97799-30 info@vitlab.com www.vitlab.com Table of contents.
More informationVIA Platform Environmental Qualification Testing Standards
VIA Platform Environmental Qualification Testing Standards Revision: 1 Report Dated: September 7 th 2016 Report Prepared By: Noel Joyce Reliability Lab Manager Page 1 of 16 Table of Contents 1. Purpose...
More informationSFI SPECIFICATION 35.2 EFFECTIVE: DECEMBER 29, 2014 *
SFI SPECIFICATION 35.2 EFFECTIVE: DECEMBER 29, 2014 * PRODUCT: Heavy Duty Stock Car Steel Wheels 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes uniform test procedures and minimum standards
More informationTEST METHOD D6121 L-37 Load Evaluation VERSION CONDUCTED FOR: I = Invalid N = Results cannot be interpreted(refer to comment section)
Load Evaluation VERSION CONDUCTED FOR: V = Valid I = Invalid N = Results cannot be interpreted(refer to comment section) NR = Non-Reference Test Oil RO = Reference Oil Result Test Stand: Date Completed:
More informationSGS TEST REPORT. Page: 1 of 8 Date: April 15,2010. itech Company LLC Christy Street, Fremont CA USA
Page: 1 of 8 Date: April 15,2010 itech Company LLC 41758 Christy Street, Fremont CA 94538 USA The following merchandise was submitted and identified by the vendor as: Product Description: 20.1 Multimedia
More informationAlberta Innovates - Technology Futures ~ Fuels & Lubricants
Report To: 5 Kings College Road Toronto, Ontario, M5S 3G8 Attention: Curtis Wan E-mail: curtis.wan@utoronto.ca Fax: Alberta Innovates - Technology Futures ~ Fuels & Lubricants 250 Karl Clark Road, Edmonton,
More informationSEP 2016 Rev D2
Product Specification 108-2112 28 SEP 2016 Rev D2 VAL-U-LOK* Connectors 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for VAL-U-LOK* Connectors. 1.2. Qualification
More informationEnvironmental Test Report
Environmental Test Report Date: March 14, 2018 Report Number: R5597 Orbital ATK Alliant Techsystems Operations LLC 4700 Nathan Lane Plymouth, MN 55442 United States 3/14/2018 Prepared By: Jessica Tonz
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 NATIONAL EXPOSURE TESTING, INC. 3211 Centennial Road Sylvania, OH 43560 Christa Lammers Phone: 419 841 1065 MECHANICAL Valid To: October 31, 2016 Certificate
More informationmga research corporation
mga research corporation UNDERGROUND TECHNOLOGIES MAN-HOLE CONSTRUCTION VERTICAL STATIC LOAD TEST SERIES (PO# 11521) 446 executive drive troy, mi 48083 248 / 577-5001 fax 248 / 577-5025 www.mgaresearch.com
More informationAugust 7, Mr. Stephen Kokenes Phone: Nomaco Inc. Fax: NMC Drive Zebulon, NC 27597
August 7, 2015 Mr. Stephen Kokenes Phone: 919-380-6636 Nomaco Inc. Fax: 919-269-7936 501 NMC Drive Email: skokenes@nomaco.com Zebulon, NC 27597 Subject: Report of ASTM D545 Testing Project Name: Samples
More informationTemperature Life with or without Electrical Load Test Procedure for Electrical Connectors and Sockets
ANSI/EIA-364-17B-1999 Approved: April 23, 1999 EIA STANDARD EIA-364-17B TP-17B Temperature Life with or without Electrical Load Test Procedure for Electrical Connectors and Sockets EIA-364-17B (Revision
More informationCERTIFICATE OF ACCREDITATION
CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Energy Assurance, LLC 5202 Belle Wood Court,
More information4th Quarter Summary of Meteorological and Ambient Air Quality Data Kennecott Utah Copper Monitoring Stations
4th Quarter 2016 Summary of Meteorological and Ambient Air Quality Data Kennecott Utah Copper Monitoring Stations Steven Root Digitally signed by Steven Root DN: cn=steven Root, o=weatherbank, Inc., ou,
More informationLife Extension Testing of Electrical Penetration Assemblies
Nuclear Division Life Extension Testing of Electrical Penetration Assemblies EQ Conference Oct 31 Nov 2, 2018 Steve Benesh, Curtiss-Wright Nuclear 1 October 22, 2018 Curtiss-Wright Summary Life Extension
More informationReport Test Report
ÖTI Institut für Ökologie, Technik und Innovation GmbH Report 70535 Test Report Applicant FIDIVI Tessitura Vegnano S.p.A. Regione Masio 19 / bis 10046 Poirino (TO) ITALIEN Reference Mr. Alessandro Avenati
More informationHi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:
TWM High Capacity Aluminium Manual Torque Wrench Range glasses/ visor and protective gloves should be worn at all times. All relevant risk assessments should be completed prior to use of the equipment.
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 NATIONAL EXPOSURE TESTING, INC. 3211 Centennial Road Sylvania, OH 43560 Christa Lammers Phone: 419 841 1065 MECHANICAL Valid To: October 31, 2018 Certificate
More informationTEST REPORT IEC Part 1: General requirements for basic safety and essential performance
jhćmtc Test Report issued under the responsibility of: TEST REPORT IEC 60601-1 Part 1: General requirements for basic safety and essential performance Report Number.... : T223-0128/16 Date of issue...
More informationTEST REPORT ENVIRONMENTAL EN 60529:1991+A1:2000
Page 1 of 15 Report No 130313TRFENV Report Reference No.... : TEST REPORT ENVIRONMENTAL EN 60529:1991+A1:2000 130313TRFENV Tested by... : Alessio Pelizzoni. Verified by... : Fabio Mauri. Date of issue...
More informationTESTING LABORATORY FOR CIVIL ENGINEERING MATERIALS
TESTING LABORATORY FOR CIVIL ENGINEERING MATERIALS INSTITUTE FOR REASEARCH OF CIVIL ENGINEERING MATERIALS, STONE- AND CONCRETE CONSTRUCTION AND FIRE INTEGRITY MPA BRAUNSCHWEIG Inspection report nr (3329/2706)
More informationCenter for Quality Engineering. Test Report No.: E0G90005
Center for Quality Engineering Order No.: E0G9 Pages: 14 Munich, Nov 30, 2011 Client: GE Intelligent Platforms GmbH & Co. KG Equipment Under Test: Wolverine 3 Manufacturer: Task: Test Specification(s):
More informationArticle: Sulfur Testing VPS Quality Approach By Dr Sunil Kumar Laboratory Manager Fujairah, UAE
Article: Sulfur Testing VPS Quality Approach By Dr Sunil Kumar Laboratory Manager Fujairah, UAE 26th September 2017 For over a decade, both regional ECA and global sulphur limits within marine fuels have
More informationSAMTEC POWER CHARACTERIZATION
Project Number: Tracking Code: Report Rev 3 Requested by: Eric Mings Date: 5/20/2013 Product Rev: 0 Part #: ET60T-00-24-06-L-RT-GP Tech: Tony Wagoner Eng: Eric Mings Part description: R/A Plug Ten60 Power
More informationTesting Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan.
11009797 002 age 1 of 11 TEST REORT Flat non-rewirable two-pole plugs, 2.5 A 250 V, with cord, for the connection of class II - equipment for household and similar purposes Report Reference No....: 11009797
More informationAmendment to Test Report
Test Report issued under the responsibility of www.nemko.com Amendment to Test Report This Amendment is valid only together with the main Test Report Report No.... : 277779 Main Report No.... : 246847
More informationProduct Specification QSL RF Connectors
Product Specification QSL RF Connectors 108-2324 04Feb09 Rev A 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the Tyco Electronics QSL RF Connectors which
More informationQUALITY REQUIREMENTS FOR JUST IN TIME SERVICE PROVIDER (JIT S.P.) PROGRAM: ALL
QUALITY REQUIREMENTS FOR JUST IN TIME SERVICE PROVIDER (JIT S.P.) PROGRAM: ALL THE CONTENT OF THIS DOCUMENT IS THE PROPERTY OF ALENIA AERONAUTICA S.p.A. THIS DOCUMENT IS SUPPLIED IN CONFIDENCE AND COMMERCIAL
More information020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)
020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 0953 Fax: +94 11 232 3935 CONTENTS Page 1.0 Scope 3 2.0 System Parameters 3 3.0 Service
More informationSFI SPECIFICATION 1.1 EFFECTIVE: NOVEMBER 9, 2001 *
SFI SPECIFICATION 1.1 EFFECTIVE: NOVEMBER 9, 2001 * PRODUCT: Replacement Flywheels and Clutch Assemblies 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes uniform test procedures and minimum
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1, 2, 3 CONTINENTAL AUTOMOTIVE SYSTEMS 2400 Executive Hills Blvd. Auburn Hills, MI 48326 Mr. David E. Swift Phone: 248 209 3813 Email: david.swift@continental-corporation.com
More informationTest certificate General construction inspection test certificate Nr. 3666/4421 -a - Fe/Wi 1. Issue ( )
Test certificate Nr. 3666/4421-a -Fe/Wi- page 1 TESTING LABORATORY FOR CIVIL ENGINEERING MATERIALS INSTITUTE FOR REASEARCH OF CIVIL ENGINEERING MATERIALS, STONE- AND CONCRETE CONSTRUCTION AND FIRE INTEGRITY
More informationFIRE ASSESSMENT REPORT FAR 4659
1222 Moonshine Road Judgeford RD1 Porirua 5381 New Zealand T +64 4 237 1170 F +64 4 237 1171 branz@branz.co.nz www.branz.co.nz FIRE ASSESSMENT REPORT FAR 4659 ASSESSMENT REPORT ON FIRE PERFORMANCE OF KNAUF
More informationSAFETY AND COMPLIANCE TESTING FOR SURESTOP
SAFETY AND COMPLIANCE TESTING FOR SURESTOP Tested Sample(s) Brand Model Color Size Vendor P/N Country of Origin Age Grading Children s Product : Bicycle Brake Pads : SureStop : SureStop Brakes Prepared
More informationRe: Online Reporting of Backflow Assembly Tests and Updates to Backflow Tester Records
Re: Online Reporting of Backflow Assembly Tests and Updates to Backflow Tester Records Dear Backflow Assembly Tester: Please note that there are significant changes to the City of Mercer Island's Testing
More informationAnnex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005
Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-11272-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 18.10.2017 to 17.10.2022 Holder of certificate: VDZ
More informationBrick Charger WD02. Total output power up to 55W. Capable of charging 5 devices simultaneously
Brick Smart Charger WD02 Brick 5 Ports USB Smart Quick Charger Charger Total output power up to 55W. Capable of charging 5 devices simultaneously WD02 Brick Charger is capable of charging five devices
More informationCompliance Test Results. of Independently Manufactured. Automotive Replacement Headlamps. to FMVSS 108. Study I. March 18, 2003
Compliance Test Results of Independently Manufactured Automotive Replacement Headlamps to FMVSS 108 Study I March 18, 2003 Prepared By Certified Automotive Parts Association 1518 K Street NW, Suite 306
More informationReport Forms Test Method D 7038 L-33-1 Version Conducted For. N = Results Cannot Be Interpreted (See Comment Section)
Report Forms Test Method D 7038 Version Conducted For V = Valid I = Invalid N = Results Cannot Be Interpreted (See Comment Section) NR = Non-Reference Test Oil RO = Reference Oil Result Test Number Motoring
More informationThe Participant will select one of the two Approval Categories (below) and submit the appropriate documentation.
FORM WCCL-PC3 WCCL TEST STAND APPROVAL PROCEDURE AND CHECKLIST AHRI CERTIFICATION PROGRAM FOR WATER-COOLED WATER CHILLING AND HEAT PUMP WATER-HEATING (WCCL) PACKAGES WCCL Participant: Date of Inspection:
More informationAnnex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005
Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D PL 11140 18 00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 06.11.2014 to 05.11.2019 Holder of certificate: Fraunhofer
More informationOverview. Mercury Monitoring. Regulatory drivers Technology Overview Pros and Cons Alternative Hybrid Approach
Mercury Compliance Monitoring in 2015 and Beyond Volker Schmid Clean Air Engineering March 28, 2013 Overview Mercury Monitoring Regulatory drivers Technology Overview Pros and Cons Alternative Hybrid Approach
More informationSFI SPECIFICATION 1.2 EFFECTIVE: FEBRUARY 9, 2006* PRODUCT: Multiple Disc Clutch Assemblies for Vehicles with Naturally Aspirated Engines
SFI SPECIFICATION 1.2 EFFECTIVE: FEBRUARY 9, 2006* PRODUCT: Multiple Disc Clutch Assemblies for Vehicles with Naturally Aspirated Engines 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes
More informationTest Report Project Nr. 2013/020
PISTON Ltd. 1033 Budapest Szőlőkert u. 4./B HUNGARY Tel: Fax: http: Email: (361)-275-0033 (361)-275-0034 www.pistonmedical.com info@pistonmedical.com Test Report Project Nr. 2013/020 Name and address of
More informationTABLE OF CONTENTS. 8.3 Online Sensor Specifications. Series TS (Models TS1, TSP, TSH, TSL,TSF, TSB1, TSB2) According to Electromatic factory procedure
8.3 Online Sensor Specifications Series TS (Models TS1, TSP, TSH, TSL,TSF, TSB1, TSB2) Calibration: Accuracy: Remainder of range and other calibration material Overload protection Measuring principle Measuring
More information