ENGINEERING AND TEST DIVISION CHURCH STREET, BOHEMIA, LONG ISLAND, NEW YORK (631)

Size: px
Start display at page:

Download "ENGINEERING AND TEST DIVISION CHURCH STREET, BOHEMIA, LONG ISLAND, NEW YORK (631)"

Transcription

1 DAYTON T. BROWNINC. Founded 1950 ENGINEERING AND TEST DIVISION CHURCH STREET, BOHEMIA, LONG ISLAND, NEW YORK (631) TEST REPORT NO: DBT04R DAYTON T. BROWN, INC. JOB NO CUSTOMER: U.S. AUTO PARTS MANUFACTURER 1410 ANY STREET SOMEWHERE, USA SUBJECT: PRODUCTION VERIFICATION TEST PROGRAM CONDUCTED ON ROOF RAIL AIR BAG MODULES SERIAL NOS PURCHASE ORDER NO.: ATTENTION: PRODUCTION SUPERVISOR THIS REPORT CONTAINS: FIVE PAGES AND EIGHT ENCLOSURES TEST ENGINEER DEPARTMENT SUPERVISOR OPERATIONS MANAGER QUALITY DEPARTMENT P. DOLAN J. BULL J. DOE J.Q. PUBLIC DATE 26 JANUARY 2002 THE DATA CONTAINED IN THIS REPORT WAS OBTAINED BY TESTING IN COMPLIANCE WITH THE APPLICABLE TEST SPECIFICATION NOTED

2 TABLE OF CONTENTS Subject Paragraph Page No. Abstract References Administrative Information Test Program Outline Number Number Enclosures of Pages of Photos (1) Service Durability (Pre) Test and Results 4 1 (2) Heat Age Dry Test and Results 5 1 (3) Storage Test and Results 5 1 (4) Thermal Shock Test and Results 4 - (5) Thermal Humidity Test and Results 6 1 (6) Salt-Spray Test and Results 4 1 (7) Service Durability (Post) Test and Results 4 - (8) A2LA Scope of Accreditation Pg 1

3 1.0 ABSTRACT This test report details the results of the production verification test program conducted on the USA Motor Company Roof Rail Air Bag Modules, under reference (a) to the requirements of reference (c). Results of the tests are detailed in the following text. The test items were nonoperating during testing. The operation of the test items was the sole responsibility of U.S. Auto Parts, Inc. personnel, and all operational data was retained by same. Test data pertinent to this program will remain on file at Dayton T. Brown, Inc. for 90 days. The test results recorded in this report relate only to those items tested. This test report shall not be reproduced, except in full, without the written approval of Dayton T. Brown, Inc Pg 2

4 2.0 REFERENCES (a) Customer Purchase Order No.: (b) Dayton T. Brown, Inc. Job No.: (c) Test Specification: U.S. Auto Parts, Inc. Specification B Pg 3

5 3.0 ADMINISTRATIVE INFORMATION Customer: U.S. Auto Parts, Inc U.S. Highway West Somewhere, USA Test Item Description: Roof Rail Air Bag Modules Quantity Received: 38 Units Serial Nos.: 1-38 Testing Sequence: Service Durability (Pre) Test Heat Age Dry Test Storage Test Thermal Shock Test Thermal Humidity Test Salt-Spray Test Service Durability (Post) Test Date Received: 18 October 1999 Test Performance Dates: 19 October through 30 December 1999 Date Shipped: 3 January Pg 4

6 4.0 TEST PROGRAM OUTLINE Test Test Item Description Results Service Durability (Pre) Roof Rail Air Bag Modules, Serial Nos Refer to Enclosure 1. Heat Age Dry Roof Rail Air Bag Modules, Serial Nos Refer to Enclosure 2. Storage Roof Rail Air Bag Modules, Serial Nos Refer to Enclosure 3. Thermal Shock Roof Rail Air Bag Modules, Serial Nos Refer to Enclosure 4. Thermal Humidity Roof Rail Air Bag Modules, Serial Nos Refer to Enclosure 5. Salt-Spray Roof Rail Air Bag Modules, Serial Nos Refer to Enclosure 6. Service Durability (Post) Roof Rail Air Bag Modules, Serial Nos Refer to Enclosure Pg 5

7 Enclosure 1 Service Durability (Pre) Test and Results

8 TEST REQUIREMENT The service durability (pre) test shall be conducted in accordance with reference (c). TEST RESULTS A pretest visual inspection of the test items revealed that there were missing screws on the cushion of Serial No. 32. All testing was performed in accordance with the referenced specification. Below are the measurements for the bridge wire resistance, shunt resistance, and insertion forces. All M6 fasteners were torqued to a value of 88 inch-pounds. The test items completed all phases of testing. A post-test visual inspection of the test items revealed no anomalies due to testing Enc 1 Pg 1

9 Electrical Resistance Measurements Service Durability (Pre) Test Serial No. Bridge Wire Resistance (Ω) Shunt Resistance (Ω) Enc 1 Pg 2

10 Service Durability (Pre) Test Insertion Forces (lb) Serial No. Trial #1 Trial #2 Trial # Enc 1 Pg 3

11 Test equipment utilized for the program reported herein was within its assigned interval of calibration. Details are on file at Dayton T. Brown, Inc. and will be made available upon request. TEST: SERVICE DURABILITY (PRE) ITEM MANUFACTURER MODEL DTB NO. ACCURACY CAL DUE DATE Push/Pull Scale Chatillon DFGS ±0.15% FS 11/19/ Digit Digital Voltmeter Hewlett-Packard 3456A 9-21 Mfr 7/23/2000 Torque Wrench Proto 6064A ±4% CW 7/30/2000 ±6% CCW Enc 1 Pg 4

12 TESTED FOR U.S. AUTO PARTS, INC. ITEM: ROOF RAIL AIR BAG MODULES TEST ITEM SETUP FOR THE CONNECTOR FORCE INSERTION MEASUREMENT IN THE SERVICE DURABILITY (PRE) TEST JOB NO FILE NO DTB04R ENCLOSURE 1 PHOTO 1

13 Enclosure 2 Heat Age Dry Test and Results

14 TEST REQUIREMENT The heat age dry test shall be conducted in accordance with reference (c). TEST RESULTS A pretest visual inspection of the test items revealed that there were no new anomalies. All testing was performed in accordance with the referenced specification. The test items completed all phases of testing. Refer to the post-heat age dry test bridge wire and shunt resistance measurements. A post-test visual inspection of the test items revealed that the metal fill tubes showed signs of discoloration turning the tubes a dark color blue Enc 2 Pg 1

15 Enc 2 Pg 2

16 Enc 2 Pg 3

17 Electrical Resistance Measurements Post-Heat Age Dry Test Serial No. Bridge Wire Resistance (Ω) Shunt Resistance (Ω) Enc 2 Pg 4

18 Test equipment utilized for the program reported herein was within its assigned interval of calibration. Details are on file at Dayton T. Brown, Inc. and will be made available upon request. TEST: HEAT AGE DRY ITEM MANUFACTURER MODEL DTB NO. ACCURACY CAL DUE DATE Temperature Chamber Dayton T. Brown, Inc. 22 Ft Temperature Controller Honeywell UDC ±2.0EF 3/26/2000 Temperature Recorder Honeywell DRT ±0.7EF 4/9/2000 Truline ±0.2% RH %RH Transmitter Rotronics HT255D ±2% RH 1/7/ Enc 2 Pg 5 %RH Transmitter Rotronic HT255D ±2% 7/9/2000 Probe

19 TESTED FOR U.S. AUTO PARTS, INC. ITEM: ROOF RAIL AIR BAG MODULES HEAT AGE DRY TEST SETUP JOB NO FILE NO DTB04R ENCLOSURE 2 S/N 1-38 PHOTO 1

20 Enclosure 3 Storage Test and Results

21 TEST REQUIREMENT The storage test shall be conducted in accordance with reference (c). TEST RESULTS A pretest visual inspection of the test items revealed that the metal fill tubes showed signs of discoloration turning the tubes a dark color blue. All testing was performed in accordance with the referenced specification. The test items completed all phases of testing. Refer to the post-storage test bridge wire and shunt resistance measurements. A post-test visual inspection of the test items revealed that there were no new anomalies due to testing Enc 3 Pg 1

22 Enc 3 Pg 2

23 Enc 3 Pg 3

24 Electrical Resistance Measurements Post-Storage Test Serial No. Bridge Wire Resistance (Ω) Shunt Resistance (Ω) Enc 3 Pg 4

25 Test equipment utilized for the program reported herein was within its assigned interval of calibration. Details are on file at Dayton T. Brown, Inc. and will be made available upon request. TEST: STORAGE ITEM MANUFACTURER MODEL DTB NO. ACCURACY CAL DUE DATE 20-Foot Temperature Atmosphere Unlimited 20 Ft Altitude Chamber Temperature/Altitude JC Systems ±1.08 F 8/13/2000 Controller Temperature Altitude Honeywell DR ±0.7 F 8/13/2000 Recorder Enc 3 Pg 5

26 TESTED FOR U.S. AUTO PARTS, INC. S/N 1-38 ITEM: ROOF RAIL AIR BAG MODULES TEST ITEMS SETUP FOR THE STORAGE TEST JOB NO FILE NO DTB04R ENCLOSURE 3 PHOTO 1

27 Enclosure 4 Thermal Shock Test and Results

28 TEST REQUIREMENT The thermal shock test shall be conducted in accordance with reference (c). TEST RESULTS A pretest visual inspection of the test items revealed that the metal fill tubes showed signs of discoloration turning the tubes a dark color blue. The test items completed all phases of testing. All testing was performed in accordance with the referenced specification. Refer to the post-thermal shock test bridge wire and shunt resistance measurements. A post-test visual inspection of the test items revealed that all the test items showed that there was slight corrosion around the initiator and some discoloration of the cushion and tether Enc 4 Pg 1

29 Enc 4 Pg 2

30 Electrical Resistance Measurements Post-Thermal Shock Test Serial No. Bridge Wire Resistance (Ω) Shunt Resistance (Ω) Enc 4 Pg 3

31 Test equipment utilized for the program reported herein was within its assigned interval of calibration. Details are on file at Dayton T. Brown, Inc. and will be made available upon request. TEST: THERMAL SHOCK ITEM MANUFACTURER MODEL DTB NO. ACCURACY CAL DUE DATE 20-Foot Temperature Atmosphere Unlimited 20 Ft Altitude Chamber Temperature/Altitude JC Systems ±1.08 F 8/13/2000 Controller Enc 4 Pg 4 Temperature Altitude Honeywell DR ±0.7 F 8/13/2000 Recorder Temperature Chamber Dayton T. Brown, Inc. 22 Ft Temperature Controller Honeywell UDC ±1.7EF 5/7/2000 Temperature Recorder Honeywell DR ±0.7EF 4/9/2000 Temperature Humidity Thermotron 24 Ft Chamber 24 Ft Temperature JC Systems ±1.08 F 7/2/2000 Humidity Controller Chart Recorder Honeywell DR ±0.5 F 7/2/2000

32 Enclosure 5 Thermal Humidity Test and Results

33 TEST REQUIREMENT The thermal humidity test shall be conducted in accordance with reference (c). TEST RESULTS For the pretest visual inspection, refer to the thermal shock test post-inspection. All testing was performed in accordance with the referenced specification. The test items completed all phases of testing. Refer to the post-thermal humidity test bridge wire and shunt resistance measurements. A post-test visual inspection of the test items revealed that all the inflators, inflator mounting brackets, initiator ends, and fill tube mounting tabs were covered with a white powdery substance and showed signs of rust. The following test items had white powder on the fill tube: Serial Nos. 2, 4, 9, 10, 11, 14, 20, 24, 30, 32, 34, 35, 36, and 38. The remaining test items had rust on the fill tube Enc 5 Pg 1

34 Enc 5 Pg 2

35 Enc 5 Pg 3

36 Enc 5 Pg 4

37 Electrical Resistance Measurements Post-Thermal Humidity Test Serial No. Bridge Wire Resistance (Ω) Shunt Resistance (Ω) Enc 5 Pg 5

38 Test equipment utilized for the program reported herein was within its assigned interval of calibration. Details are on file at Dayton T. Brown, Inc. and will be made available upon request. TEST: THERMAL HUMIDITY ITEM MANUFACTURER MODEL DTB NO. ACCURACY CAL DUE DATE Temperature/Humidity Webber/Thermotron 10 Ft Chamber Digital Control JC Systems ±1.08 F 9/24/2000 Indicator ±1.06% RH Temperature & %RH Honeywell DR45AT ±0.5 F 9/24/2000 Chart Recorder ±0.2% RH Enc 5 Pg 6 % RH Probe Vaisala HMP ±1% 0 90% 7/2/2000 ±2% %

39 TESTED FOR U.S. AUTO PARTS, INC. S/N 1-38 ITEM: ROOF RAIL AIR BAG MODULES TEST ITEMS SETUP FOR THE THERMAL HUMIDITY TEST JOB NO FILE NO DTB04R ENCLOSURE 5 PHOTO 1

40 Enclosure 6 Salt-Spray Test and Results

41 TEST REQUIREMENT The salt-spray test shall be conducted in accordance with reference (c). TEST RESULTS For the pretest visual inspection, refer to the thermal humidity test post-inspection. All testing was performed in accordance with the referenced specification. The test items completed all phases of testing. Refer to the post-salt-spray test bridge wire and shunt resistance measurements. A post-test visual inspection of the test items revealed the following: - Inflator mounting bracket showed signs of oxidation and very slight amounts of rust. - Inflator showed signs of oxidation. - Fill tube showed signs of rust and oxidation Enc 6 Pg 1

42 Enc 6 Pg 2

43 Electrical Resistance Measurements Post-Salt-Spray Test Serial No. Bridge Wire Resistance (Ω) Shunt Resistance (Ω) , Enc 6 Pg 3

44 Test equipment utilized for the program reported herein was within its assigned interval of calibration. Details are on file at Dayton T. Brown, Inc. and will be made available upon request. TEST: SALT-SPRAY ITEM MANUFACTURER MODEL DTB NO. ACCURACY CAL DUE DATE Salt-Fog Chamber Industrial Filter and 21 Ft Pump Mfg. Co. Temperature Honeywell UDC ±2.0EF 9/17/2000 Controller/Indicator Pressure Gauge Weiss Instruments 0 to psi Enc 6 Pg 4 Pressure Gauge Weiss Instruments 0 to psi Petri Dish Fisher Corning 100 x % Indefinite 50 mm -10% Graduate Nalgene 50 ml ±0.5 ml 4/8/2001 Hydrometer Fisher F 39-9 Mfr 10/1/2000 ph Meter Cole-Palmer ±0.10 ph Each Day Temperature Recorder Doric ±1EF 6/11/2000 Resistivity Meter Myron L. Co ±1% FS 9/10/2000

45 TESTED FOR U.S. AUTO PARTS, INC. S/N 1-38 ITEM: ROOF RAIL AIR BAG MODULES SALT-SPRAY TEST SETUP JOB NO FILE NO DTB04R ENCLOSURE 6 PHOTO 1

46 Enclosure 7 Service Durability (Post) Test and Results

47 TEST REQUIREMENT The service durability (post) test shall be conducted in accordance with reference (c). TEST RESULTS For the pretest visual inspection refer to the salt-spray test post-inspection. All testing was performed in accordance with the referenced specification. Below are the measurements for the bridge wire resistance, shunt resistance, and insertion forces. All M6 fasteners were torqued to a value of 88 inch-pounds. The test items completed all phases of testing. A post-test visual inspection of the test items revealed that there were no new anomalies due to testing Enc 7 Pg 1

48 Electrical Resistance Measurements Service Durability (Post) Test Serial No. Bridge Wire Resistance (Ω) Shunt Resistance (Ω) Enc 7 Pg 2

49 Service Durability (Post) Test Insertion Forces (lb) Serial No. Trial 1 Trial 2 Trial 3 Trial 4 Trial 5 Trial 6 Trial Enc 7 Pg 3

50 Test equipment utilized for the program reported herein was within its assigned interval of calibration. Details are on file at Dayton T. Brown, Inc. and will be made available upon request. TEST: SERVICE DURABILITY (POST) ITEM MANUFACTURER MODEL DTB NO. ACCURACY CAL DUE DATE Digital Volt/Ohm Meter Hewlett-Packard 3456A 9-22 Mfr 6/11/2000 Push/Pull Scale Chatillon DFGS ±0.15% FS 11/19/2000 Torque Wrench Proto 6064A Data 12/17/ Enc 7 Pg 4

51 Enclosure 8 A2LA Scope of Accreditation

52 Enc 8 Pg 1

53 Enc 8 Pg 2

Environmental Test Report

Environmental Test Report Environmental Test Report Date: March 14, 2018 Report Number: R5597 Orbital ATK Alliant Techsystems Operations LLC 4700 Nathan Lane Plymouth, MN 55442 United States 3/14/2018 Prepared By: Jessica Tonz

More information

SmartSensor 105 & Advance NEMA Salt Fog

SmartSensor 105 & Advance NEMA Salt Fog SmartSensor 105 & Advance NEMA Salt Fog Test Report Wavetronix products mentioned: SmartSensor 105 SmartSensor Advance As contracted by Wavetronix, Environ Laboratories LLC performed a NEMA salt fog test

More information

AUGUST 28, 2008 TEST REPORT # REV.1.1 MIXED FLOWING GAS TESTING CONNECTOR SERIES CLP S-D-A FTSH S-DV-A SAMTEC, INC.

AUGUST 28, 2008 TEST REPORT # REV.1.1 MIXED FLOWING GAS TESTING CONNECTOR SERIES CLP S-D-A FTSH S-DV-A SAMTEC, INC. AUGUST 28, 2008 TEST REPORT #208383-3 REV.1.1 MIXED FLOWING GAS TESTING CONNECTOR SERIES CLP-130-02-S-D-A FTSH-130-02-S-DV-A SAMTEC, INC. APPROVED BY: DOMINIC ARPINO PROGRAM MANAGER CONTECH RESEARCH, INC.

More information

AUGUST 28, 2008 TEST REPORT # REV.1.1 MIXED FLOWING GAS TESTING CONNECTOR SERIES SEM H-D-WT TEM H-D-WT SAMTEC, INC.

AUGUST 28, 2008 TEST REPORT # REV.1.1 MIXED FLOWING GAS TESTING CONNECTOR SERIES SEM H-D-WT TEM H-D-WT SAMTEC, INC. AUGUST 28, 2008 TEST REPORT #208383-5 REV.1.1 MIXED FLOWING GAS TESTING CONNECTOR SERIES SEM-125-02-03.0-H-D-WT TEM-125-02-03.0-H-D-WT SAMTEC, INC. APPROVED BY: DOMINIC ARPINO PROGRAM MANAGER CONTECH RESEARCH,

More information

UN TEST SEQUENCE TEST REPORT

UN TEST SEQUENCE TEST REPORT UN TEST SEQUENCE TEST REPORT 24183-05 1 72 PREPARED FOR: Mr. William J. Smirles Senior Vice President Heartsine Technologies, Inc. 940 Calle Amanecer Suite E San Clemente, CA 92673 PREPARED BY: Trace Laboratories

More information

VIA Platform Environmental Qualification Testing Standards

VIA Platform Environmental Qualification Testing Standards VIA Platform Environmental Qualification Testing Standards Revision: 1 Report Dated: September 7 th 2016 Report Prepared By: Noel Joyce Reliability Lab Manager Page 1 of 16 Table of Contents 1. Purpose...

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 NORTHERN BALANCE AND SCALE, INC. 9556 W. Bloomington Freeway Bloomington, MN 55431 Joey Kaluser Phone: 952 881 7716 CALIBRATION Valid

More information

CLIMATE. Climate and temperature chambers.

CLIMATE. Climate and temperature chambers. Climate and temperature chambers. The Environmental Competence Centre has a number of climate chambers at its disposal to carry out low and high temperature tests, as well as a number of combined climate

More information

SPECIFICATION AND PERFORMANCE TABLE OF CONTENT. 1. Scope Reference Documents Material and Components... 2

SPECIFICATION AND PERFORMANCE TABLE OF CONTENT. 1. Scope Reference Documents Material and Components... 2 TABLE OF CONTENT 1. Scope... 2 2. Reference Documents.. 2 3. Material and Components...... 2 4. Design and Construction..... 2 5. Rating.. 2 6. Performance and Test Descriptions. 2 7. Test Requirements

More information

Reliability Test Report

Reliability Test Report Reliability Test Report Page 1 of 29 Reliability flow Chart: Page 2 of 29 Test Group 1 1.1 Dimensional Analysis: 1.1.1 Test Purpose: These measurements are to verify that the units meet the dimensional

More information

Lightweight Shock Test Report on Power Supply PS1503-H-MB and Adapter Plate for Powerstar Inc. Gaithersburg, MD

Lightweight Shock Test Report on Power Supply PS1503-H-MB and Adapter Plate for Powerstar Inc. Gaithersburg, MD Test Report No. 11543.1 No. of Pages 14 Lightweight Shock Test Report on Power Supply PS1503-H-MB and Adapter Plate for Powerstar Inc. Gaithersburg, MD NU LABORATORIES 312 Old Allerton Road, Annandale,

More information

SAMTEC POWER CHARACTERIZATION

SAMTEC POWER CHARACTERIZATION Project Number: Tracking Code: Power Report Rev 3 Requested by: Eric Mings Date: 9/11/2012 Product Rev: AE Part #: MMSD-25-24-L-12.00-D-K-LUS Lot #: «Lot_Number» Tech: Tony Wagoner Eng: Eric Mings Part

More information

DESIGN VERIFICATION TEST REPORT HLE/TSM HLE G-DV/TSM G-DV

DESIGN VERIFICATION TEST REPORT HLE/TSM HLE G-DV/TSM G-DV Project Number: Design Verification Test Report Tracking Code: _Report_Rev_1 Requested by: Mark Shireman Date: 9/30/2010 Product Rev: 0 Lot #: na Tech: Tony Wagoner Eng: Eric Mings Qty to test: 15 Test

More information

2.0 TEST PROCEDURES AND RESULTS Vibration Test TEST EQUIPMENT AND INSTRUMENTATION QUALITY ASSURANCE PROGRAM 7 ATTACHMENTS

2.0 TEST PROCEDURES AND RESULTS Vibration Test TEST EQUIPMENT AND INSTRUMENTATION QUALITY ASSURANCE PROGRAM 7 ATTACHMENTS Page No. 2 TABLE OF CONTENTS Page No. 1.0 INTRODUCTION 3 1.1 Scope 3 1.2 References 3 1.3 Test Specimen Description 3 1.4 Summary 3 2.0 TEST PROCEDURES AND RESULTS 4 2.1 Vibration Test 4 3.0 TEST EQUIPMENT

More information

SEP 2016 Rev D2

SEP 2016 Rev D2 Product Specification 108-2112 28 SEP 2016 Rev D2 VAL-U-LOK* Connectors 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for VAL-U-LOK* Connectors. 1.2. Qualification

More information

THERMAL SHOCK TEST REPORT

THERMAL SHOCK TEST REPORT Report No. :DH1509300024A Version:A THERMAL SHOCK TEST REPORT Company :FLIP CHIP OPTO. INC. Address :No.185, Kewang Rd., Longtan Dist., Taoyuan City 325, Taiwan (R.O.C.) Model Name :Apollo 600-B Lot Number

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 NATIONAL EXPOSURE TESTING, INC. 3211 Centennial Road Sylvania, OH 43560 Christa Lammers Phone: 419 841 1065 MECHANICAL Valid To: October 31, 2016 Certificate

More information

TEMPERATURE - HUMIDITY VAISALA HMP155

TEMPERATURE - HUMIDITY VAISALA HMP155 TEMPERATURE - HUMIDITY VAISALA HMP155 SENSOR MEASURE SIGNAL OUTPUT ELECTRICAL SUPPLY MODEL IN EOL MANAGER Temperature 0...1 V 7 28 V VAISALA HMP45A Humidity 0...1 V 7 28 V VAISALA HMP45A APPLICATION The

More information

TEMPORARY REVISION NUMBER

TEMPORARY REVISION NUMBER TEMPORARY REVISION NUMBER 7 DATED 1 DECEMBER 2011 MANUAL TITLE MANUAL NUMBER - PAPER COPY TEMPORARY REVISION NUMBER Model 188 & T188 Series 1966 Thru 1984 Service Manual D2054-1-13 D2054-1TR7 MANUAL DATE

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 NATIONAL EXPOSURE TESTING, INC. 3211 Centennial Road Sylvania, OH 43560 Christa Lammers Phone: 419 841 1065 MECHANICAL Valid To: October 31, 2018 Certificate

More information

Lightweight Shock and Type I Vibration Test Report on UPS Model No. PS3200RM for Powerstar Inc. Gaithersburg, MD

Lightweight Shock and Type I Vibration Test Report on UPS Model No. PS3200RM for Powerstar Inc. Gaithersburg, MD Test Report No. 12069.1 No. of Pages 21 Lightweight Shock and Type I Vibration Test Report on UPS Model No. PS3200RM for Powerstar Inc. Gaithersburg, MD NU LABORATORIES 312 Old Allerton Road, Annandale,

More information

SAMTEC POWER CHARACTERIZATION

SAMTEC POWER CHARACTERIZATION Project Number: Tracking Code: Report Rev 3 Requested by: Eric Mings Date: 5/20/2013 Product Rev: 0 Part #: ET60T-00-24-06-L-RT-GP Tech: Tony Wagoner Eng: Eric Mings Part description: R/A Plug Ten60 Power

More information

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter Flow Control Components - SMARTLINK METER 10-30.9-1 SMARTLINK METER Digital Self-checking Thermal Mass Flow Meter Precise, repeatable mass flow measurement for fuel, air and combustion streams Displays

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 DEKRA IST RELIABILITY SEVICES INC. No. 22 Puding Rd., East Dist. Hsinchu City 300, Taiwan, R.O.C. Phone: 886 3 579 5766 ext 7100 Mr. General Lee general.lee@dekra-ist.com

More information

May08 Rev C

May08 Rev C Product Specification 0.64 mm Generation Y Terminal 108-2296 20May08 Rev C 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the Tyco Electronics 0.64 mm Generation

More information

Serial Attached SCSI (SAS) Connector

Serial Attached SCSI (SAS) Connector Product 108-51053 Specification DR: Stanley Huang 24 Oct 2013 Rev G APVD: Vincent Peng Serial Attached SCSI (SAS) Connector 1.0 SCOPE This specification covers the requirements for product performance,

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares

More information

SPECIFICATION SHEET P700L CURRENT LIMITING FUSE SURFACE MOUNT MODEL

SPECIFICATION SHEET P700L CURRENT LIMITING FUSE SURFACE MOUNT MODEL 11525 Sorrento Valley Rd. San Diego, California 92121 (858) 481-0210 SPECIFICATION SHEET P700L CURRENT LIMITING FUSE SURFACE MOUNT MODEL REVISION: A B C D E F G H J DATE: 10/95 2/96 2/00 10/95 2/96 10/98

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: Mexical Metrología, S.A. de C.V. Tecnología de Materiales,

More information

DEVELOPMENTAL HALT Report R XSS S Power Supplies. Michael Farragher Engineering Test Technician Test Performed By

DEVELOPMENTAL HALT Report R XSS S Power Supplies. Michael Farragher Engineering Test Technician Test Performed By DEVELOPMENTAL HALT Report Product Tested: Service Proposal #: XSS00-24S Power Supplies S00000354 Job #: J09135-5198 Date Received: th March 2014 Test Dates: th to 14 th March 2014 Report Date: 4 th March

More information

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter Flow Control Components - SMARTLINK METER 10-30.9-1 SMARTLINK METER Digital Self-checking Thermal Mass Flow Meter Precise, repeatable mass flow measurement for fuel, air and combustion streams Displays

More information

REPORT NUMBER: 120-MGA

REPORT NUMBER: 120-MGA REPORT NUMBER: 120-MGA-2011-001 SAFETY COMPLIANCE TESTING FOR FMVSS NO. 120 TIRE SELECTION AND RIMS FOR MOTOR VEHICLES WITH A GVWR OF MORE THAN 4,536 kg FOREST RIVER, INC. / STARCRAFT DIVISION 2011 STARCRAFT

More information

MINIMUM REQUIREMENTS FOR MOTOR VEhICLE BRAkE LININGS -SAE J998

MINIMUM REQUIREMENTS FOR MOTOR VEhICLE BRAkE LININGS -SAE J998 Appendix A Appendix MINIMUM REQUIREMENTS FOR MOTOR VEhICLE BRAkE LININGS -SAE J998 SAE Recommended Practice 1. Scope - This specification covers brake linings used on motor vehicles operated on the public

More information

May2015 Rev A

May2015 Rev A Product Specification 108-60104 15May2015 Rev A ANGLED ENTRY JACK FOR CATEGORY 6 APPLICATIONS 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the TE Connectivity

More information

FEBRRUARY 22, 2008 TEST REPORT # QSH/QTH/QTE SERIES CONNECTOR SHEAR TESTING SAMTEC, INC.

FEBRRUARY 22, 2008 TEST REPORT # QSH/QTH/QTE SERIES CONNECTOR SHEAR TESTING SAMTEC, INC. FEBRRUARY 22, 2008 TEST REPORT #207908 QSH/QTH/QTE SERIES CONNECTOR SHEAR TESTING SAMTEC, INC. APPROVED BY: DOMINIC ARPINO PROGRAM MANAGER CONTECH RESEARCH, INC. Contech Research REVISION HISTORY DATE

More information

Distributed By: M&M Control Service, Inc PRODUCT PRODUCT CODE RESOURCE DOCUMENTS PAGE #

Distributed By: M&M Control Service, Inc PRODUCT PRODUCT CODE RESOURCE DOCUMENTS PAGE # PRODUCT PRODUCT CODE RESOURCE DOCUMENTS PAGE # Pneumatic Receiver-Controllers Single Input Receiver-Controller RC 195 155-119P25 C-3 Multiple Input Receiver-Controller RC 195 155-036P25 C-5 Pneumatic Transmitters

More information

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-20258-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 2016-02-02 to 2021-02-01 Holder of certificate: Amphenol-Tuchel

More information

CONTINUOUS IMMERSION AND DUST TEST REPORT

CONTINUOUS IMMERSION AND DUST TEST REPORT Report No. :HS1404020081A Version:A CONTINUOUS IMMERSION AND DUST TEST REPORT Company Address :Taiway Electronics Components Co. :4F., No. 4, 6, 8, Lane 359, Sec. 2, Zhongshan Rd., Zhonghe Dist., New Taipei

More information

Qualification Testing of Meritec High Power Conformal Connector 107 position, short (.22 inch stack height) and tall (.33 inch stack height) versions

Qualification Testing of Meritec High Power Conformal Connector 107 position, short (.22 inch stack height) and tall (.33 inch stack height) versions Qualification Testing of Meritec High Power Conformal Connector 107 position, short (.22 inch stack height) and tall (.33 inch stack height) versions Project 1256 Scope: Test 1 per EIA-364-23 - determine

More information

TEST REPORT ENVIRONMENTAL EN 60529:1991+A1:2000

TEST REPORT ENVIRONMENTAL EN 60529:1991+A1:2000 Page 1 of 15 Report No 130313TRFENV Report Reference No.... : TEST REPORT ENVIRONMENTAL EN 60529:1991+A1:2000 130313TRFENV Tested by... : Alessio Pelizzoni. Verified by... : Fabio Mauri. Date of issue...

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORYACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares

More information

ANNEX 13. UNIFIED INTERPRETATIONS TO MARPOL ANNEX VI AND THE NO x TECHNICAL CODE

ANNEX 13. UNIFIED INTERPRETATIONS TO MARPOL ANNEX VI AND THE NO x TECHNICAL CODE MARPOL Annex VI Regulation 1 Application Regulation 1 reads as follows: UNIFIED INTERPRETATIONS TO MARPOL ANNEX VI AND THE NO x TECHNICAL CODE The provisions of this Annex shall apply to all ships, except

More information

MILITARY SPECIFICATION LUBRICATING OIL, VACUUM PUMP, MECHANICAL

MILITARY SPECIFICATION LUBRICATING OIL, VACUUM PUMP, MECHANICAL INCH-POUND MIL-DTL-83767C 24 September 2007 SUPERSEDING MIL-L-83767B 8 February 1980 MILITARY SPECIFICATION LUBRICATING OIL, VACUUM PUMP, MECHANICAL Reactivated after 24 September 2007 and may be used

More information

ACE Variable Frequency Drive System

ACE Variable Frequency Drive System ACE Variable Frequency Drive System Installation & Maintenance Information SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE IF 1690 BLOWER COOLING INTAKE SHROUDS BLOWER FUSE BLOCK TEMPERATURE CONTROLLER TRANSFORMER

More information

TTH-1315 TTH-1315-A Temperature & Humidity Sensor User s Manual

TTH-1315 TTH-1315-A Temperature & Humidity Sensor User s Manual Relied on Worldwide in the Most Extreme Conditions TTH-1315 TTH-1315-A Temperature & Humidity Sensor User s Manual Texas Electronics, Inc. Dallas, TX 75237 Fax.214.631.4218 4230 Shilling Way Tel.214-631-2490

More information

Megohmmeter Test Probe

Megohmmeter Test Probe Megohmmeter Test Probe User Manual ENGLISH www.aemc.com CHAUVIN ARNOUX GROUP Copyright Chauvin Arnoux, Inc. d.b.a. AEMC Instruments. All rights reserved. No part of this documentation may be reproduced

More information

SAFETY RECALL GL1800-8A AIRBAG MODULE REPLACEMENT

SAFETY RECALL GL1800-8A AIRBAG MODULE REPLACEMENT Honda has undertaken a SAFETY RECALL on certain 2006-2012 GL1800-8A motorcycles to replace the airbag module. The airbag module in affected motorcycles includes a potentially defective inflator manufactured

More information

Instruction Manual. Digital Panel Meter Model 3126 CAUTION. Code Type of T/C Measuring Range Display Range Accuracy

Instruction Manual. Digital Panel Meter Model 3126 CAUTION. Code Type of T/C Measuring Range Display Range Accuracy Instruction Manual Digital Panel Meter Model 3126 I-01861 1. Preface Thank you for purchasing our digital panel meter 3126 series. Before use, read this manual carefully and thoroughly, and keep this manual

More information

RSS Truck Suspension Self-Steer Air-Ride Suspension System for Customer-Supplied I-Beam Axle

RSS Truck Suspension Self-Steer Air-Ride Suspension System for Customer-Supplied I-Beam Axle RSS-2361000-Truck Suspension Self-Steer Air-Ride Suspension System for Customer-Supplied I-Beam Axle Installation and Service Manual Suspension Identification... 2 Suspension System Serial Tag Prior to

More information

INSTRUCTION MANUAL ANCHOR LOAD CELL. Model ANCLO

INSTRUCTION MANUAL ANCHOR LOAD CELL. Model ANCLO INSTRUCTION MANUAL ANCHOR LOAD CELL Model ANCLO Roctest Limited 2009. All rights reserved This product should be installed and operated only by qualified personnel. Its misuse is potentially dangerous.

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 CONTINENTAL AUTOMOTIVE SYSTEMS 570 Capital Drive Lake Zurich, IL 60047 Mr. Ken Klimek (Authorized Representative) Phone: 847-862-0131 Email: ken.klimek@continental-corporation.com

More information

TO BE RESCINDED. 3. Wood, paper and plastic pallets, spacers or packaging materials. 4. Polymerization or other molecular rearrangements.

TO BE RESCINDED. 3. Wood, paper and plastic pallets, spacers or packaging materials. 4. Polymerization or other molecular rearrangements. ACTION: Final DATE: 12/04/2017 11:40 AM 1301:7-7-21 Industrial ovens. TO BE RESCINDED (A) Section 2101 General (1) 2101.1 Scope. This rule shall apply to the installation and operation of industrial ovens

More information

TEMPORARY REVISION NUMBER

TEMPORARY REVISION NUMBER TEMPORARY REVISION NUMBER 8 DATED 1 DECEMBER 2011 MANUAL TITLE MANUAL NUMBER - PAPER COPY TEMPORARY REVISION NUMBER 1978 Thru 1986 Model R182 & TR182 Service Manual D2069-3-13 D2069-3TR8 MANUAL DATE 15

More information

SERVICE BULLETIN THIS BULLETIN IS FAA APPROVED FOR ENGINEERING DESIGN

SERVICE BULLETIN THIS BULLETIN IS FAA APPROVED FOR ENGINEERING DESIGN MOONEY AIRPLANE COMPANY, INC. SERVICE BULLETIN Louis Schreiner Field Kerrville, Texas 78028 DATE: October 30, 2003 THIS BULLETIN IS FAA APPROVED FOR ENGINEERING DESIGN SERVICE BULLETIN M20-282 DATE: October

More information

Section 12: Record Keeping Requirements. Minnesota Trucking Regulations

Section 12: Record Keeping Requirements. Minnesota Trucking Regulations Section 12: Record Keeping Requirements Minnesota Trucking Regulations 89 Section 12 Record Keeping Requirements 49 CFR Part 390 Motor carriers who are subject to the Federal Motor Carrier Safety Regulations

More information

Cold Resistance (Ohm) Note 1

Cold Resistance (Ohm) Note 1 P700L Series Part Numbering System P700L - 72-1.0 Fuse Type Voltage Amp Part Number/Rating Cold Resistance (Ohm) Note 1 Overload Interrupt Time (Second) Nominal Rating - Note 2/3 Maximum I 2 T (Ampere

More information

TEMPORARY REVISION NUMBER

TEMPORARY REVISION NUMBER TEMPORARY REVISION NUMBER 7 DATED 1 DECEMBER 2011 MANUAL TITLE MANUAL NUMBER - PAPER COPY TEMPORARY REVISION NUMBER FR172 Reims Rocket 1968 Thru 1976 Service Manual D849-5-13 D849-5TR7 MANUAL DATE 15 August

More information

MEZALOK* Stacking Connector System

MEZALOK* Stacking Connector System Product Specification 108-2411 25 FEB 16 Rev D MEZALOK* Stacking Connector System 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the MEZALOK* Stacking Connector

More information

Jun06 Rev D

Jun06 Rev D Product Specification High Speed Serial Data 2 Connector 108-1965 27Jun06 Rev D 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the Tyco Electronics High

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares

More information

SPECIFICATION SHEET P600L CURRENT LIMITING FUSE

SPECIFICATION SHEET P600L CURRENT LIMITING FUSE 11525 Sorrento Valley Rd. San Diego, California 92121 (858) 481-0210 SPECIFICATION SHEET P600L CURRENT LIMITING FUSE REVISION: A B C D E F G H J K DATE: 11/87 5/90 5/92 7/94 6/95 12/95 6/96 1/97 11/99

More information

INSTRUCTION MANUAL AND PARTS LIST FOR SERIES 8L-630J AND 630M WARNING

INSTRUCTION MANUAL AND PARTS LIST FOR SERIES 8L-630J AND 630M WARNING INSTRUCTION MANUAL AND PARTS LIST FOR SERIES 8L-630J AND 630M WARNING READ CA-l AND TIDS INSTRUCTION MANUAL PRIOR TO INSTALLATION, OPERATION OR MAINTENANCE WARNING This Instruction Manual and General Instructions

More information

E/ECE/324/Rev.2/Add.102/Rev.1 E/ECE/TRANS/505/Rev.2/Add.102/Rev.1

E/ECE/324/Rev.2/Add.102/Rev.1 E/ECE/TRANS/505/Rev.2/Add.102/Rev.1 30 August 2011 Agreement Concerning the adoption of uniform technical prescriptions for wheeled vehicles, equipment and parts which can be fitted and/or be used on wheeled vehicles and the conditions for

More information

Torque Wrenches

Torque Wrenches - 171 - Digital Torque Wrenches Digital Torque Wrenches The new AmPro digital torque wrenches are designed for simple and precise measurement of industrial, automotive, aerospace and many other applications.

More information

SM1206 Series. Overload Interrupt Time (Second) Nominal Rating - Note 2. Cold Resistance (Ohm) Note 1. Maximum I 2 T (Ampere 2 Second) Nominal Rating

SM1206 Series. Overload Interrupt Time (Second) Nominal Rating - Note 2. Cold Resistance (Ohm) Note 1. Maximum I 2 T (Ampere 2 Second) Nominal Rating SM1206 Series Part Numbering System SM1206-32 - 1.0 Fuse Type Voltage Amp Part Number/Rating Cold Resistance (Ohm) Note 1 Overload Interrupt Time (Second) Nominal Rating - Note 2 Maximum I 2 T (Ampere

More information

Low Pressure Sensor. Overview. Specifications. Installation and Operation

Low Pressure Sensor. Overview. Specifications. Installation and Operation Overview The Low Pressure Sensor with display measures building pressure, air velocities and volumes. The heart of the unit is a micro-machined silicon pressure sensor. The unit includes a static pressure

More information

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators Installation D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators IMPORTANT: The D- Series actuators are intended to control equipment under normal operating conditions. Where failure

More information

National Board Update

National Board Update National Board Update Presentation to the Valve Repair Council June 2, 2016 Prepared by: Joseph F. Ball, P.E. National Board Update National Board activities Who we are and what we do National Board Inspection

More information

MEASUREMENT AND TEST REPORT

MEASUREMENT AND TEST REPORT IES LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT For Guangzhou Hongli Opto-Electronic Co., Ltd. West side of Dongfeng Highway, Automobile industrial Base, Huadu

More information

Report Number: G CRT-001A Model Number: Ionflow 50 Surface ARB Number: 1334

Report Number: G CRT-001A Model Number: Ionflow 50 Surface ARB Number: 1334 3933 US Route 11 Cortland, NY 13045 Telephone: +01 607 753 6711 Facsimile: +01 607 756 9891 www.intertek-etlsemko.com Order No. G100222377 28 January 2011 Revised 11 November 2011 Report Number: G100222377CRT-001A

More information

Product Specification Rev A

Product Specification Rev A Product Specification 108-6116 1. Scope :.5 Signal DBL Lock Connector 18P 1.1 Contents This specification covers the requirements for product performance, test methods and quality assurance provisions

More information

Replacing Tram Motor Dual Sprocket W/Brake Disc Assembly - (LH or RH)

Replacing Tram Motor Dual Sprocket W/Brake Disc Assembly - (LH or RH) Replacing Tram Motor Dual Sprocket W/Brake Disc Assembly - (LH or RH) Function Remove and replace the tram motor dual sprocket with integral brake disc assembly. The brake calipers are of the spring-set,

More information

92021 Automatic Tank Gauge. Features. Automatic Tank Gauge. 1/16 Accuracy. 90 Foot gauging range. Simple installation. Ground or roof reading

92021 Automatic Tank Gauge. Features. Automatic Tank Gauge. 1/16 Accuracy. 90 Foot gauging range. Simple installation. Ground or roof reading 92021 The Shand & Jurs 92021 Automatic Tank Level Gauge is a float actuated tape driven gauge and by means of a digital counter indicates float travel accurately to 1/16 inch. The 92021 meets all the specifications

More information

Reference Number: SMS-3517-L1A, Rev 0 Date: November 7, 2014

Reference Number: SMS-3517-L1A, Rev 0 Date: November 7, 2014 Reference Number: SMS-3517-L1A, Rev 0 Date: November 7, 2014 Owen Oil Tools LP 12001 County Road 1000 Godley, Texas 76044 Attention: Subject: Ben Potter Shipping Classification Recommendation for the OOT-APRV-064

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ELITE ELECTRONIC ENGINEERING, INC. 1 1516 Centre Circle Downers Grove, IL 60515 Larry Brooks (QA Manager) Phone: 630 495 9770 ext. 166 Email: lbrooks@elitetest.com

More information

Types P551 and P551A External Closing Spring Retrofit Kits for the Type N550/N551 ESV

Types P551 and P551A External Closing Spring Retrofit Kits for the Type N550/N551 ESV Instruction Manual MCK-1189 Types P551 and P551A October 2015 Types P551 and P551A External Closing Spring Retrofit Kits for the Type N550/N551 ESV! WARNING Failure to follow these instructions or to properly

More information

T21 Thermal Differential Switch

T21 Thermal Differential Switch T21 Thermal Differential Switch General Instructions The T21 Point Level Switch is a state-of-the-art in liquid level and interface measurement and control. Level detection is accomplished by using a high-resolution

More information

Compliance Certification Services Inc. Report No: MIL(CS101) Date of Issue: August 12, 2009 MIL STD 461E/ F TEST REPORT.

Compliance Certification Services Inc. Report No: MIL(CS101) Date of Issue: August 12, 2009 MIL STD 461E/ F TEST REPORT. Compliance Certification Services Inc. MIL STD 461E/ F TEST REPORT For 20.1 Multimedia LCD Monitor Model Number: WMRM920-PIP Trade Name: itech Issued to itech Company LLC 41758 Christy Street, Fremont

More information

Cardinal DETECTO. PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual

Cardinal DETECTO. PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual Cardinal DETECTO PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual CARDINAL SCALE MFG. CO. PO BOX 151, WEBB CITY, MO 64870 0066-M176-O1 Rev H 10/06 417-673-4631 www.cardinalscale.com Printed

More information

Drying Cabinets and Vacuum Machines for Moisture Sensitive Components

Drying Cabinets and Vacuum Machines for Moisture Sensitive Components Drying Cabinets and Vacuum Machines for Moisture Sensitive Components Drying Cabinet SD-Series Optimal protection with minimal deployment. User-friendly operation and compact construction guarantee safe

More information

LAKE CITY POLICE DEPARTMENT GENERAL ORDERS MANUAL

LAKE CITY POLICE DEPARTMENT GENERAL ORDERS MANUAL LAKE CITY POLICE DEPARTMENT GENERAL ORDERS MANUAL SUBJECT Traffic Enforcement Measuring Devices CHIEF OF POLICE Signature on File NUMBER 126 ISSUE DATE July 8, 2010 REVISION DATE TOTAL PAGES 5 AUTHORITY/RELATED

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: (Hereinafter called the Organization) and hereby declares

More information

Summary of HALT, IPx7 & IP69K testing for AT Series connectors

Summary of HALT, IPx7 & IP69K testing for AT Series connectors S1-15227 Rev. A1 Corp. SINE Systems Corporation 44724 Morley Drive Clinton Twp, MI 48036 Summary of HALT, IPx7 & IP69K testing for AT Series connectors IPx7 (Submersion) PASS Requirements: Acceptance conditions

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET Hydrazine monitor

ABB MEASUREMENT & ANALYTICS DATA SHEET Hydrazine monitor ABB MEASUREMENT & ANALYTICS DATA SHEET 7835 Hydrazine monitor 2 78 35 H YDR AZ I N E MON I TOR DS / 78 3 5-E N RE V. L Measurement made easy Advanced transmitter Auto-ranging with remote range indication

More information

Shriram Institute For Industrial Research, 14-15, Sadarmangala Industrial Area, Whitefield Road, Bangalore, Karnataka

Shriram Institute For Industrial Research, 14-15, Sadarmangala Industrial Area, Whitefield Road, Bangalore, Karnataka Certificate Number CC-2083 (in lieu of C-0216, C-0304, C-1497) Page 1 of 7 ELECTRO-TECHNICAL CALIBRATION I. MEASURE 1. Time $ 5 sec to 9900 sec 0.12 sec to 5.8 sec Using Digital Time Totalizer (Digital

More information

PRODUCT SPECIFICATION

PRODUCT SPECIFICATION PRODUCT SPECIFICATION Buyer Name Buyer spart No. Buyer s Approval & Signatures /Spec No. Product Description /Part No. /Date /Designed by Coin type vibration motor /Checked by /Approved by / WANG ZX /

More information

Pressure transmitter for marine applications MBS 33M

Pressure transmitter for marine applications MBS 33M Data sheet Pressure transmitter for marine applications MBS 33M The standard pressure transmitter MBS 33M is designed for use in almost all marine applications, and offers a reliable pressure measurement,

More information

E/ECE/324/Rev.1/Add.38/Rev.2 E/ECE/TRANS/505/Rev.1/Add.38/Rev.2

E/ECE/324/Rev.1/Add.38/Rev.2 E/ECE/TRANS/505/Rev.1/Add.38/Rev.2 E/ECE/324/Rev.1/Add.38/Rev.2 24 January 2018 Agreement Concerning the Adoption of Harmonized Technical United Nations Regulations for Wheeled Vehicles, Equipment and Parts which can be Fitted and/or be

More information

XK3190- A7. Weighing indicator USER MANUAL

XK3190- A7. Weighing indicator USER MANUAL XK3190- A7 Weighing indicator USER MANUAL Directory Chapter 1. Main Specification......,,...2 Chapter 2 Installation...,...3 Front and Back View of Indicator...,..3 Connecting Loadcell to Indicator...,...4

More information

SECTION METERS AND GAUGES FOR HVAC PIPING

SECTION METERS AND GAUGES FOR HVAC PIPING SECTION 23 05 19 METERS AND GAUGES FOR HVAC PIPING PART 1 - GENERAL 1.1 SUMMARY A. Work included: Provision of materials, installation and testing of: 1. Thermometers 2. Thermometer Wells 3. Differential

More information

Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050

Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050 Data sheet Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050 The compact heavy duty pressure transmitters MBS 2000 and MBS 2050 are designed for use in hydraulic applications. MBS

More information

SAFETY COMPLIANCE TESTING FOR FMVSS 110 TIRE SELECTION AND RIMS

SAFETY COMPLIANCE TESTING FOR FMVSS 110 TIRE SELECTION AND RIMS REPORT NUMBER 110-STF-09-001 SAFETY COMPLIANCE TESTING FOR TIRE SELECTION AND RIMS GENERAL MOTORS CORPORATION 2009 CHEVROLET IMPALA FOUR-DOOR PASSENGER CAR NHTSA NO. C90100 U.S. DOT SAN ANGELO TEST FACILITY

More information

Thermo Scientific APEX 500 Rx Metal Detector User s Guide. REC 4345 Rev B Part number English

Thermo Scientific APEX 500 Rx Metal Detector User s Guide. REC 4345 Rev B Part number English Thermo Scientific APEX 500 Rx Metal Detector User s Guide REC 4345 Rev B Part number 109541 English 2010 Thermo Fisher Scientific, Inc. All rights reserved For future reference, write your APEX 500 Rx

More information

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) 020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB) CEYLON ELECTRICITY BOARD SRI LANKA Telephone: +94 11 232 0953 Fax: +94 11 232 3935 CONTENTS Page 1.0 Scope 3 2.0 System Parameters 3 3.0 Service

More information

SOUTH AFRICAN NATIONAL STANDARD

SOUTH AFRICAN NATIONAL STANDARD ISBN 978-0-626-19459-8 SOUTH AFRICAN NATIONAL STANDARD Verification standards for the verification of volume-measuring instruments, including commercial standards of volume Published by Standards South

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: Torreón, Coahuila, México C.P. 27019 (Hereinafter

More information

3M Three-Wall and Four-Wall Headers. Series 3XXX

3M Three-Wall and Four-Wall Headers. Series 3XXX 1 of 7 M Three-Wall and Four-Wall Headers Series XXX Product 78-10-0008-0 Released: 0-0-11 of 7 Table of Contents Section Page 1. Scope........ M Customer Documents....... Performance and Test Descriptions...

More information

Compact Low Pressure Sensor

Compact Low Pressure Sensor Overview The Low Pressure Sensor is a true differential pressure transmitter that provides ±1 inches WC (±250 Pacals) in 10 field selectable ranges (see specifications). The enclosure is designed for DIN

More information

Pressure transmitter for air and water applications Type MBS 1900

Pressure transmitter for air and water applications Type MBS 1900 Data sheet Pressure transmitter for air and water applications Type MBS 1900 The pressure transmitter MBS 1900 is designed for use in air and water applications like Booster Pumps and Air Compressors.

More information