Center for Quality Engineering. Test Report No.: E0G90005

Size: px
Start display at page:

Download "Center for Quality Engineering. Test Report No.: E0G90005"

Transcription

1 Center for Quality Engineering Order No.: E0G9 Pages: 14 Munich, Nov 30, 2011 Client: GE Intelligent Platforms GmbH & Co. KG Equipment Under Test: Wolverine 3 Manufacturer: Task: Test Specification(s): [covered by accreditation] Test Specification(s): [not covered by accreditation] unknown Conformance test according to the test specifications mentioned below IEC Degrees of protection provided by enclosures (IP Code) Test IPX5 IEC Degrees of protection provided by enclosures (IP Code) Test IP6X Result: The tests are passed and compliant to the specifications. The results relate only to the items tested as described in this test report. approved by: Date Signature Garcia-Baglietto Lab Manager Environmental Simulation Dec 02, 2011 This document was signed electronically. The Center for Quality Engineering of SGS Germany GmbH is accredited by DAkkS for COMPONENTS TESTING ENVIRONMENTAL ENGINEERING ELECTROMAGNETIC COMPATIBILITY PRODUCT SAFETY TELECOM CONFORMANCE TESTS SGS Germany GmbH, SGS CQE, Hofmannstr. 50, D München, Phone , Fax , Internet

2 CONTENTS 1 Summary References Specifications General Information Identification of Client Test Laboratory Time Schedule Participants Equipment Under Test Test Equipment Test Facility Measuring Equipment Test Specifications and Results Test Specification Test Performance IPX5-Test IP6X-Test Test Result IPX5-Test IP6X-Test Enclosures...11 Date: Nov 30, 2011 Wolverine 3 page 2 / 14

3 1 Summary Tested Requirement(s) IEC Degrees of protection provided by enclosures (IP Code) IEC Degrees of protection provided by enclosures (IP-Code) Test Case IPX5 IP6X Remark The test is passed and compliant to the specifications The test is passed and compliant to the specifications 2 References 2.1 Specifications [1] IEC 60529: Degrees of protection provided by enclosures (IP-Code) 3 General Information 3.1 Identification of Client GE Intelligent Platforms GmbH & Co. KG Memminger Str Augsburg Philipp Hortmann 3.2 Test Laboratory Center for Quality Engineering SGS Germany GmbH Hofmannstraße München TÜV Product Service Ridlerstr München Date: Nov 30, 2011 Wolverine 3 page 3 / 14

4 3.3 Time Schedule Delivery of EUT: Nov 15, 2011 Start of test: Nov 18, 2011 End of test: Nov 22, Participants Name Function Phone Claus-Peter Finsterer Accredited testing, Editor Equipment Under Test 1 housing Wolverine 3 Pic. 1 Description of EUT: Label Date: Nov 30, 2011 Wolverine 3 page 4 / 14

5 5 Test Equipment 5.1 Test Facility The measurements were carried out in the Center for Quality Engineering SGS Germany GmbH, Department Environmental Simulation Hofmannstraße 50, München, Germany. 5.2 Measuring Equipment ID No. Equipment Type Manufacturer Specification Statu s Last Cal. Next Cal. S1383 Sun/Rain-Room Eigenbau IP Test, NEMA, UL cnn Test S5861 Stopwatch Mesotron Quartz Hanhart cal Sep 22, 2010 Sep 2012 S5389 Mass Flow Recorder Aquaflux F Krohne cal Apr 07, 2011 Apr 2012 S5422 Nozzle 6.3mm 6.3 mm QE cnn cal = Calibration, car = Calibration restricted use, chk = Check, chr = Check restricted use, cpu = Check prior to use, cnn = Calibration not necessary, ind = for indication only 6 Test Specifications and Results The test results in the report refer exclusively to the test object described in section 4 and the test period in section Test Specification Test Parameter Test Severity Reference IPX5 Internal diameter of nozzle Delivery rate Test duration Distance to EUT 6,3 mm 12 l/min 3 min 2,5-3 m IEC IP6X Dust Duration Under pressure Talcum 8 h 20 mbar IEC Date: Nov 30, 2011 Wolverine 3 page 5 / 14

6 6.2 Test Performance IPX5-Test Pic. 2 EUT at IPX5 Test Date: Nov 30, 2011 Wolverine 3 page 6 / 14

7 6.2.2 IP6X-Test Pic. 3 EUT after IP6X-Test The IP6X-Test was performed by an external laboratory Date: Nov 30, 2011 Wolverine 3 page 7 / 14

8 6.3 Test Result IPX5-Test No water penetrates in the housing (see pictures 4,5+6 ). The test is passed and conform to the specification. Pic. 4 EUT after IP5X-Test. No water penetrates in the housing Pic. 5 EUT after IP5X-Test. No water penetrates in the housing Date: Nov 30, 2011 Wolverine 3 page 8 / 14

9 Pic. 6 EUT after IP5X-Test. No water penetrates in the housing IP6X-Test The test was performed by an external laboratory (see test report chapter 7) No dust penetrates into the housing ( see pictures 7, 8+9) The test is passed and conform to the specification. Pic. 7 EUT after IP6X-Test. No dust penetrates into the housing Date: Nov 30, 2011 Wolverine 3 page 9 / 14

10 Pic. 8 EUT after IP6X-Test. No dust penetrates into the housing Pic. 9 EUT after IP6X-Test. No dust penetrates into the housing Date: Nov 30, 2011 Wolverine 3 page 10 / 14

11 7 Enclosures Date: Nov 30, 2011 Wolverine 3 page 11 / 14

12 Date: Nov 30, 2011 Wolverine 3 page 12 / 14

13 Date: Nov 30, 2011 Wolverine 3 page 13 / 14

14 Date: Nov 30, 2011 Wolverine 3 page 14 / 14

Center for Quality Engineering. Test Report No.: T09YSR1K

Center for Quality Engineering. Test Report No.: T09YSR1K TTI-P-G 57/97-0 Center for Quality Enineerin Test Report No.: Order No.: T09Y Paes: 8 Enclosures : 7 Munich, 5 Feb. 2005 Client: Schroff Sas Z.I 4 rue du Marais F-67660 Betschdorf France Equipment under

More information

CERTIFICATE of QUALITY TEST

CERTIFICATE of QUALITY TEST Test lab CERTIFICATE of QUALITY TEST according to DIN 55 350-18 - 4.3.4. DAP-PL-3439.00 Test report - No. 7564 / 09 Client FALCOM Wireless Communications GmbH Gewerbering 6 98704 Langenwiesen Equipment

More information

TEST REPORT IEC Degrees of protection provided by enclosures ( Partially for IP65 test )

TEST REPORT IEC Degrees of protection provided by enclosures ( Partially for IP65 test ) TEST REPORT IEC 60529 Degrees of protection provided by enclosures ( Partially for IP65 test ) Report reference No...: L113061055 Compiled by (+ signature)...: see cover sheet... Approved by (+ signature)...:

More information

CONTINUOUS IMMERSION AND DUST TEST REPORT

CONTINUOUS IMMERSION AND DUST TEST REPORT Report No. :HS1404020081A Version:A CONTINUOUS IMMERSION AND DUST TEST REPORT Company Address :Taiway Electronics Components Co. :4F., No. 4, 6, 8, Lane 359, Sec. 2, Zhongshan Rd., Zhonghe Dist., New Taipei

More information

SERVICES SafE e-mobility for SuRE! CoNSultaNCy testing HomoloGatIoN CERtIfICatIoN

SERVICES SafE e-mobility for SuRE! CoNSultaNCy testing HomoloGatIoN CERtIfICatIoN SERVICES Safe e-mobility for sure! CONSULTANCY TESTING HOMOLOGATION CERTIFICATION With 64,000 employees worldwide the SGS Group is the leader in the fields of testing, verification and certification. Founded

More information

TEST REPORT. No. 284a/14

TEST REPORT. No. 284a/14 Labor für Umwelterprobung und Werkstoffprüfung Telefon +49 (0) 3 41 / 4 84 32-25 Telefax +49 (0) 3 41 / 4 84 32-14 E-Mail umwelterprobung@tzoleipzig.de Technologie-Zentrum für Oberflächentechnik und Umweltschutz

More information

2 nd use application of battery cells: functional safety requirements

2 nd use application of battery cells: functional safety requirements 2 nd use application of battery cells: functional safety requirements Workshop: Regulatory Qualification Requirements for Battery Storages March 3 rd 2018 AGENDA Introduction of project MiBZ What means

More information

PRO-TYP II. Single and 3-phase Test Adapter with Type 2 Plug for Testing Electric Charging Stations with PROFITEST MTECH+ and MXTRA

PRO-TYP II. Single and 3-phase Test Adapter with Type 2 Plug for Testing Electric Charging Stations with PROFITEST MTECH+ and MXTRA PRO-TYP II Single and 3-phase Test Adapter with Type 2 Plug for Testing Electric Charging Stations with PROFITEST MTECH+ and MXTRA 3-349-884-03 1/10.15 Opening of Equipment / Repair The equipment may be

More information

THE UNITED KINGDOM VEHICLE APPROVAL AUTHORITY

THE UNITED KINGDOM VEHICLE APPROVAL AUTHORITY THE UNITED KINGDOM VEHICLE APPROVAL AUTHORITY COMMUNICATION CONCERNING THE APPROVAL GRANTED (1) TO A COMPONENT TYPE- APPROVAL CERTIFICATE IN RESPECT OF A NON-ORIGINAL EXHAUST SYSTEM FOR A TYPE OF MOTORCYCLE

More information

No , Vers.1

No , Vers.1 Pag. 1 of 4 TEST REPORT No. Test performed in accordance with the standard ASTM B 117 (2003) issued by TÜV Rheinland Italia S.r.l. - Via Gavardina Trav. II, 42 I-25010 Ponte S. Marco (BS) 1. General information

More information

CERTIFICATE. EN tested QAL 1 certified TUV approved Annual inspection. The certificate is valid until: 19 July Köln, 17 August 2012

CERTIFICATE. EN tested QAL 1 certified TUV approved Annual inspection. The certificate is valid until: 19 July Köln, 17 August 2012 :~ ~~~~~============~----------------------~ Umwelt Bundes Amt @ For our Environment A TÜVRheinland Precisely Right. CERTIFICATE on Product Conformity (QAL 1) Number of Certificate: 0000035014 Certified

More information

10KW Portable EV Charger

10KW Portable EV Charger 10KW Portable EV Charger SET450-20BX User manual 1 / 12 SAVE THESE INSTRUCTIONS This manual contains important instructions for 10KW portable charger that shall be followed during installation, operation

More information

Industrial plug-in connectors HEAVYCON EVO. efficient at a twist of the wrist

Industrial plug-in connectors HEAVYCON EVO. efficient at a twist of the wrist Industrial plug-in connectors HEAVYCON EVO efficient at a twist of the wrist For more efficiency in your system HEAVYCON EVO Heavy-duty plug-in connectors are established on the market and are used in

More information

THERMAL SHOCK TEST REPORT

THERMAL SHOCK TEST REPORT Report No. :DH1509300024A Version:A THERMAL SHOCK TEST REPORT Company :FLIP CHIP OPTO. INC. Address :No.185, Kewang Rd., Longtan Dist., Taoyuan City 325, Taiwan (R.O.C.) Model Name :Apollo 600-B Lot Number

More information

INVERTER APPROVAL FOR INSTALLATION IN ISRAEL

INVERTER APPROVAL FOR INSTALLATION IN ISRAEL 05.02.18 v.5 INVERTER APPROVAL FOR INSTALLATION IN ISRAEL STANDARDS APPLIED FOR SAFETY EVALUATION OF INVERTERS: AS/NZS 3100 Approval and test specification General requirements for electrical equipment

More information

Adjustable IPX3 / IPX4 Test Systems Built in accordance with IEC 60529, and meeting EN 60539, IEC 60335, IEC 60950, EN 60335, and others

Adjustable IPX3 / IPX4 Test Systems Built in accordance with IEC 60529, and meeting EN 60539, IEC 60335, IEC 60950, EN 60335, and others PROUCT SAFETY SOLUTIONS OSCILLATING SPRAY TEST SYSTEMS MOELS OTU-1000 and OTU-1600 Adjustable IPX3 / IPX4 Test Systems Built in accordance with IEC 60529, and meeting EN 60539, IEC 60335, IEC 60950, EN

More information

Certificate of Calibration

Certificate of Calibration Model Number Manufacturer Description Serial Number DSOX2014A Keysight Technologies Inc Oscilloscope, 4-channel, 100MHz MY52161639 Date of Calibration 5 Dec 2014 Procedure STE-50114571-A.02.00 Temperature

More information

Commercial-in-Confidence Ashton Old Baths Financial Model - Detailed Cashflow

Commercial-in-Confidence Ashton Old Baths Financial Model - Detailed Cashflow Year 0 1 2 3 4 5 6 7 8 9 10 11 12 13 Oct-16 Nov-16 Dec-16 Jan-17 Feb-17 Mar-17 Apr-17 May-17 Jun-17 Jul-17 Aug-17 Sep-17 Oct-17 2,038 2,922 4,089 4,349 6,256 7,124 8,885 8,885 8,885 8,885 8,885 8,885 9,107

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Type 6027 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions contain

More information

Influence of mounting tube diameter on anemometer output

Influence of mounting tube diameter on anemometer output Influence of mounting tube diameter on anemometer output In cooperation with: Adolf Thies GmbH & Co. KG Hauptstraße 76 37083 Göttingen Germany Deutsche WindGuard Wind Tunnel Services GmbH Oldenburger Str.

More information

TEST REPORT ENVIRONMENTAL EN 60529:1991+A1:2000

TEST REPORT ENVIRONMENTAL EN 60529:1991+A1:2000 Page 1 of 15 Report No 130313TRFENV Report Reference No.... : TEST REPORT ENVIRONMENTAL EN 60529:1991+A1:2000 130313TRFENV Tested by... : Alessio Pelizzoni. Verified by... : Fabio Mauri. Date of issue...

More information

Solenoid Operator 0516 / 1216

Solenoid Operator 0516 / 1216 nass magnet GmbH Edition no. 2 Eckenerstraße 4-6 2007-01-10 D-30179 Hannover Rev.2 070110 Solenoid Operator 0516 / 1216 Operating Instructions NN 8220 126 and EC Declaration of Conformity Dear Customer!

More information

THE UNITED KINGDOM VEHICLE APPROVAL AUTHORITY

THE UNITED KINGDOM VEHICLE APPROVAL AUTHORITY THE UNITED KINGDOM VEHICLE APPROVAL AUTHORITY COMMUNICATION CONCERNING THE APPROVAL GRANTED (1) TO A COMPONENT TYPE- APPROVAL CERTIFICATE IN RESPECT OF A NON-ORIGINAL EXHAUST SYSTEM FOR A TYPE OF MOTORCYCLE

More information

Solenoid Operator 0513 / 1213

Solenoid Operator 0513 / 1213 nass magnet GmbH Run Nr. 5 Eckenerstraße 4-6 24.10.2006 D-30179 Hannover Rev. 5 061024 Solenoid Operator 0513 / 1213 Operating Instructions NN 8220 112 and EC Declaration of Conformity Dear Customer! In

More information

Operating Instructions for Float Flow Meter / Monitor. Model: SWK

Operating Instructions for Float Flow Meter / Monitor. Model: SWK Operating Instructions for Float Flow Meter / Monitor Model: SWK 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 4 5. Operating Principle... 4 6. Use in Hazardous

More information

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue ENEC LICENCE Licence No. ENEC-01360 Page 1/3 Date of Issue 2016-03-04 Licence Holder WAGO KONTAKTTECHNIK GMBH & CO KG HANSASTRASSE 27 MINDEN, 32423 Germany Production site WAGO CONTACT SA ROUTE DE L'INDUSTRIE

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Type 5282 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions contain

More information

Alberta Innovates - Technology Futures ~ Fuels & Lubricants

Alberta Innovates - Technology Futures ~ Fuels & Lubricants Report To: 5 Kings College Road Toronto, Ontario, M5S 3G8 Attention: Curtis Wan E-mail: curtis.wan@utoronto.ca Fax: Alberta Innovates - Technology Futures ~ Fuels & Lubricants 250 Karl Clark Road, Edmonton,

More information

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en Snap-action switches S80, S85, S86 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D0.en Snap-action switches, S80, S85, S86 Series Single-break

More information

3 RD RAIL SWITCH FHT-KS 4000 DISCONNECTOR

3 RD RAIL SWITCH FHT-KS 4000 DISCONNECTOR 3 RD RAIL SWITCH FHT-KS 4000 DISCONNECTOR www.kraus.com www.kraus.com KRAUS RAILWAY TECHNOLOGY PRODUCT LINE Pantograph Switches Trackside Disconnectors Disconnectors & Earthing Switches Pneumatic Interlock

More information

Cal. YM92A. φ27.0 mm H 3.7 mm. S.EPSON Products

Cal. YM92A. φ27.0 mm H 3.7 mm. S.EPSON Products Cal. YM92A φ27.0 mm H 3.7 mm Items Rev. Page Specifications 03 1 Appearance 00 2 Casing 03 3 Hand fitting 01 4 Hand setting stem 01 5 Dial-01 01 6-01 Dial-02 00 6-02 Dial-03 00 6-03 Dial-04 00 6-04 Casing

More information

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-11321-02-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 20.12.2016 to 19.12.2021 Holder of certificate: TÜV

More information

BMW i. Freude am Fahren. Wallbox PURE. Installation instruction

BMW i. Freude am Fahren. Wallbox PURE. Installation instruction BMW i Freude am Fahren Wallbox PURE Installation instruction Imprint Bestellnummer 61 90 2 347 662 Wallbox Pure Type T2 (32 A, 7.4 kw) Publisher Bayerische Motorenwerke Aktiengesellschaft Munich, Germany

More information

SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL

SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL MOTORTECH Tools & Test Equipment for Ignition Systems P/N 01.10.019 Rev. 01/2013 Copyright Copyright 2012 MOTORTECH GmbH. All rights reserved. Distribution

More information

SECULIFE PS100 PATIENT SIMULATOR

SECULIFE PS100 PATIENT SIMULATOR Operating Instructions SECULIFE PS100 PATIENT SIMULATOR 3-349-714-03 1/05.13 TABLE OF CONTENTS Page WARNINGS, CAUTIONS, NOTICES... 4 DESCRIPTION SECULIFE PS100 Patient Simulator... 7 LAYOUT... 9 LIMITED

More information

For the National Voluntary Laboratory Accreditation Program

For the National Voluntary Laboratory Accreditation Program SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 Florida Department of Agriculture Metrology Laboratory 3125 Conner Blvd. Lab #2 Tallahassee, FL 32399-1650 Ms. Amy Smith Phone: 850-921-1570 Fax: 850-921-1593

More information

TOPAS 2130A (Draft v3)

TOPAS 2130A (Draft v3) TOPAS 2130A (Draft v3) Revision Date Scope Authorised by A (v1) 10/10/17 Draft A (v2) 11/11/17 Draft A (v3) 15/12/17 Draft Traffic Open Products And Specifications Limited 2017. This document is the property

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 16059155 001 Date of issue... : Apr.24,

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation Type 0131 2/2- or 3/2-way solenoid valve 2/2- oder 3/2-Wege-Magnetventil Électrovanne 2/2 ou 3/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating

More information

Test Report. E4S-Box V1.0

Test Report. E4S-Box V1.0 Test Report No. 05 / 5040-1-1a E4S-Box V1.0 S/N: 8 The results refer only to the tested equipment. Without written permission of the test laboratory it is allowed to publish parts of this test report.

More information

Services Transport and PackagingTests Optimizationof Packagings Environmental Simulation Tests, Design Testing IP-Testing Packaging Validation and Pac

Services Transport and PackagingTests Optimizationof Packagings Environmental Simulation Tests, Design Testing IP-Testing Packaging Validation and Pac Accredited Test Lab for Environmental and Transport Simulation Tests HAMBURG BERLIN OCHSENHAUSEN CH-NEUHAUSEN Services Transport and PackagingTests Optimizationof Packagings Environmental Simulation Tests,

More information

Page 2 of 23 UNT150420C11

Page 2 of 23 UNT150420C11 Page 2 of 23 UNT150420C11 United Nations, Recommendations on the Transport of Dangerous Goods, Manual of Test and Criteria (Rev. 5 th, Amendment 2), Section 38.3 Report Reference No.... : Compiled by...

More information

Conductivity Measurement CLM 280

Conductivity Measurement CLM 280 Technical Information TI 347C/07/en/07.03 51511754 Conductivity Measurement CLM 280 Battery-driven pocket meter for conductivity and resistance measurement Application CLM 280 is a compact pocket meter

More information

Type Pneumatic actuators

Type Pneumatic actuators Homepage > Products > External louvres - louvre blades > Multileaf dampers > Attachments > Type Pneumatic actuators Type Pneumatic actuators PNEUMATIC ACTUATORS FOR THE OPENING AND CLOSING OF DAMPERS IN

More information

Series 3730 Electropneumatic Positioner Type

Series 3730 Electropneumatic Positioner Type Series 3730 Electropneumatic Positioner Type 3730-1 Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating, automatic adaptation to valve and

More information

esense article overview E series Document ID: E1409_ _esense 9000 article overview_r10.00

esense article overview E series Document ID: E1409_ _esense 9000 article overview_r10.00 esense article overview E1409-9000 series Document ID: E1409_20180518_esense 9000 article overview_r10.00 esense is a product by: Indes Production Management Pantheon 28 7521 PR Enschede PO box 265 7500

More information

2 Rittal climate control/wall-mounted cooling units Blue e+

2 Rittal climate control/wall-mounted cooling units Blue e+ World s first The principle 2 Rittal climate control/wall-mounted cooling units Blue e+ The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have bundled

More information

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Type 5282 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 Operating Instructions... 2 2 Authorized use...

More information

THE UNITED KINGDOM VEHICLE APPROVAL AUTHORITY EU TYPE-APPROVAL CERTIFICATE

THE UNITED KINGDOM VEHICLE APPROVAL AUTHORITY EU TYPE-APPROVAL CERTIFICATE Communication concerning: EU type-approval extension of EU type-approval refusal of EU type-approval withdrawal of EU type-approval THE UNITED KINGDOM VEHICLE APPROVAL AUTHORITY EU TYPE-APPROVAL CERTIFICATE

More information

WATERFLUX 3070 Quick Start

WATERFLUX 3070 Quick Start WATERFLUX 3070 Quick Start Battery powered electromagnetic water meter Electronic Revision ER 4.3.0_ up to ER 4.3.4_ (SW.REV 4.2.2_ up to 4.2.5_) KROHNE CONTENTS WATERFLUX 3070 1 Safety instructions 4

More information

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05 DL 0 Battery Powered for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless

More information

PHOENIX CONTACT - 01/2008

PHOENIX CONTACT - 01/2008 Exi Solenoid Driver, With Intrinsically Safe Output, LoopPowered, TwoChannel INTERFACE Data Sheet 0289_00_en PHOENIX CONTACT 0/2008 Description The PIEXME2SD/24/65C is a twochannel solenoid driver. It

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 207809-CI3-3 CB DE1-9640/A2 Date of issue...

More information

Battery Li-Ion BA21. Data sheet LINAK.COM/MEDLINE-CARELINE

Battery Li-Ion BA21. Data sheet LINAK.COM/MEDLINE-CARELINE Battery Li-Ion BA21 Data sheet LINAK.COM/MEDLINE-CARELINE BA21 Li-Ion The BA21 Li-Ion back-up battery pack has been specially developed for use with the new control boxes COxx and CAxx, e.g. CO61 and CA40,

More information

Technical capability. Innovation R&D. Global Collaboration

Technical capability. Innovation R&D. Global Collaboration ARTC PROFILE 2017 1 Content ARTC Briefing Technical capability Innovation R&D Global Collaboration 2 ARTC Briefing Basic Information Date of establishment Founded by Government/Industry on Oct 8,1990 Employee

More information

Status report / Activity Plan of OBD Task Force

Status report / Activity Plan of OBD Task Force -20-12e Status report / Activity Plan of OBD Task Force 26 th Sep., 2017 Mayumi Sophie Morimoto (JASIC) OBD TF Goal agreed at 1 st OBD TF (15 th Dec. 2016) Develop harmonized OBD GTR by end of 2018*. *Approved

More information

Requirements for Energy storage systems (ESS) Ralf Martin Müller

Requirements for Energy storage systems (ESS) Ralf Martin Müller Requirements for Energy storage systems (ESS) 2014-10-14 Ralf Martin Müller 1 TÜV Rheinland 2 Risks, Hazards 3 ESS Application and Conditions of Operation 4 Standardisation - Focus on Safety und Quality

More information

Sun Sensor setting in PumpScanner Daily output in average month 52 m³ Daily values Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Av.

Sun Sensor setting in PumpScanner Daily output in average month 52 m³ Daily values Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Av. Parameter Location: Afghanistan, Baglan (36 North; 68 East) Water temperature: 25 C Required daily output: 50 m³; Sizing for average month Dirt loss: 2.0 % Motor cable: 100 m Pipe type: - Total dynamic

More information

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content 1. About this document Operating instructions.............pages 1 to 6 Original 1.1 Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning

More information

RADIO FREQUENCY SYSTEMS

RADIO FREQUENCY SYSTEMS C14520.016-E.MU0 DOC.:10000008168-02 LAB4 DEHYDRATOR USER MANUAL 1 DRYING CHAMBER 2 HEATER 3 PUMP 4 AIR BACKWASHING HOLE 5 HUMIDITY PROBE 6 DIGITAL PRESSURE GAUGE 7 RELIEF VALVE 8 SHUT OFF VALVE 9 DRY

More information

VIBRATION TEST REPORT

VIBRATION TEST REPORT Report No. :HS1505160024A-1 Version:B VIBRATION TEST REPORT Company Address :Cincon Electronics Co., Ltd. :No.8-1 Fu Kung Rd., Fu Hsing ind. Park, Fu Hsing Hsiang, Chang Hua Hsien, Taiwan, R.O.C. Model

More information

SHOCK TEST REPORT. :Cincon Electronics Co., Ltd. Hua Hsien, Taiwan, R.O.C. :EC7BW-110S15, ECLB40W-110S05, CQB60W-110S24

SHOCK TEST REPORT. :Cincon Electronics Co., Ltd. Hua Hsien, Taiwan, R.O.C. :EC7BW-110S15, ECLB40W-110S05, CQB60W-110S24 Report No. :HS1505160024A-2 Version:B SHOCK TEST REPORT Company Address :Cincon Electronics Co., Ltd. :No.8-1 Fu Kung Rd., Fu Hsing ind. Park, Fu Hsing Hsiang, Chang Hua Hsien, Taiwan, R.O.C. Model Name

More information

EMS ELONGATION MEASUREMENT SYSTEM. Strain measurement system for wind turbines optimizing the control & condition monitoring

EMS ELONGATION MEASUREMENT SYSTEM. Strain measurement system for wind turbines optimizing the control & condition monitoring EMS ELONGATION MEASUREMENT SYSTEM Strain measurement system for wind turbines optimizing the control & condition monitoring 2 1 1 3 3 EMS ELONGATION MEASUREMENT SYSTEM 1 Rotor blade Rotor blades are the

More information

OPTISWITCH 6500 C Technical Datasheet

OPTISWITCH 6500 C Technical Datasheet OPTISWITCH 6500 C Technical Datasheet Microwave Level Switch for advanced hygienic applications Optimised sensor geometry, easy to clean Measures products with dielectric constant > 1.5 Maintenance-free

More information

Daily output in May 32 m³

Daily output in May 32 m³ Parameter Location: Serbia, Novi Sad (45 North; 19 East) Total dynamic head: 50 m Required daily output: 30 m³; Sizing for May Motor cable: 55 m Dirt loss: 5.0 % Pipeline: - Water temperature: 20 C Products

More information

Conveyor Chains for Coal-Fired Power Stations

Conveyor Chains for Coal-Fired Power Stations Conveyor Chains for Coal-Fired Power Stations THIELE your Partner for Coal-Fired Power Stations The Company THIELE has been a leading manufacturer of industrial chains for more than 70 years. The company

More information

Type 6213 EV, 6281 EV

Type 6213 EV, 6281 EV Type 6213 EV, 6281 EV 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions

More information

HIGH VOLTAGE LABORATORY INSTYTUT ENERGETYKI

HIGH VOLTAGE LABORATORY INSTYTUT ENERGETYKI HIGH VOLTAGE LABORATORY INSTYTUT ENERGETYKI POLAND 01-330 WARSZAWA, ul. Mory 8, tel. (+48 22) 836-80-48, fax (+48 22) 836-80-48 e-mail: ewn@ien.com.pl EWN/70/E/11-1 APPENDIX 3 APPENDIX 3 for test report

More information

Daily output in April 193 m³ Daily values Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Av.

Daily output in April 193 m³ Daily values Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Av. Parameter Location: Cyprus, Limassol (34 North; 33 East) Swimming pool volume 85 m³ Daily turnover rate 2 times Required daily output: 170 m³; Sizing for April Dirt loss: Motor cable: 4.0 m Pipe type:

More information

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements Test Report issued under the responsibility of: TEST REPORT IEC 60950-1 Information technology equipment Safety Part 1: General requirements Report Number.... : 31282706.003 Date of issue... : 22 nd March,

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ELEMENT MATERIALS TECHNOLOGY MINNEAPOLIS LLC (A subsidiary of Element Materials Technology Minneapolis Inc.) 9725 Girard Avenue South Minneapolis, MN 55431

More information

Ex m Solenoid Operator Type 0519

Ex m Solenoid Operator Type 0519 nass magnet GmbH Eckenerstrasse 4-6 D-30179 Hannover Doc. No. 113-720-0002 Revision No. 2 01.06.2015 Ex m Solenoid Operator Type 0519 Operating Instructions Dear Customer! To ensure the function and for

More information

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-20258-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 2016-02-02 to 2021-02-01 Holder of certificate: Amphenol-Tuchel

More information

OPTISWITCH 6500 C Technical Datasheet

OPTISWITCH 6500 C Technical Datasheet OPTISWITCH 6500 C Technical Datasheet Switch for level detection and dry-run protection Optimised sensor geometry, easy to clean Measures products with dielectric constant > 1.5 Maintenance-free KROHNE

More information

SPARK PLUG CLEANING KIT OPERATING MANUAL

SPARK PLUG CLEANING KIT OPERATING MANUAL SPARK PLUG CLEANING KIT OPERATING MANUAL Spark Plugs - Tools & Accessories P/N 01.20.002 Rev. 08/2015 Copyright Copyright 2015 MOTORTECH GmbH. All rights reserved. Distribution and reproduction of this

More information

Level Measuring Sensor for Diesel Fuel Tanks

Level Measuring Sensor for Diesel Fuel Tanks Installation and Operating Manual Level Measuring Sensor for Diesel Fuel Tanks Executions with switchable output voltage signal: 0-2.3 V and industrial standard signal 0-10 V: Tank Sensor Diesel 010-250

More information

AS/NZS AS/NZS

AS/NZS AS/NZS TEST REORT AS/NZS 4777.2 AS/NZS 4777.3 Grid connection of energy systems via inverters Grid protection requirements Report reference number... : 13TH0287-AS/NZS 4777_0 Date of issue......: 2014-01-22 Total

More information

TEST METHOD D6121 L-37 Load Evaluation VERSION CONDUCTED FOR: I = Invalid N = Results cannot be interpreted(refer to comment section)

TEST METHOD D6121 L-37 Load Evaluation VERSION CONDUCTED FOR: I = Invalid N = Results cannot be interpreted(refer to comment section) Load Evaluation VERSION CONDUCTED FOR: V = Valid I = Invalid N = Results cannot be interpreted(refer to comment section) NR = Non-Reference Test Oil RO = Reference Oil Result Test Stand: Date Completed:

More information

Differential Pressure Sensors

Differential Pressure Sensors 1 910 1910P01 Differential Pressure Sensors for air or nonaggressive gases QBM66... Pressure-linear characteristic with selectable pressure measuring range Operating voltage AC 24 V or DC 13.5...33 V Output

More information

SAMPLE PERMIT APPLICATION PACKAGE

SAMPLE PERMIT APPLICATION PACKAGE 2013 Lennox Industries Inc. Dallas, Texas, USA SOLAR - KIT / ACCESSORIES 507154-01 3/2013 Supersedes 506555-01 LITHO U.S.A. SAMPLE PERMIT APPLICATION PACKAGE SUNSOURCE HOME ENERGY SYSTEM SAMPLE PERMIT

More information

Technical Documentation

Technical Documentation Technical Documentation Product manual Holding brake controller Document: 0198441113316 Edition: V1.00, 03.2006 Important information The drive systems described here are products for general use that

More information

Limit Switch Type 4747

Limit Switch Type 4747 Limit Switch Type 4747 Ex d flameproof enclosure with inductive or mechanical contacts for linear actuators or rotary actuators acc. to VDI/VDE 3845 General The Type 4747 Limit Switch issues an electrical

More information

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate 1 919 1919P01 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate Highly accurate measurements with calibration certificate Simple and quick

More information

OPTIFLUX 2000 Quick Start

OPTIFLUX 2000 Quick Start OPTIFLUX 2000 Quick Start Electromagnetic flow sensor The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS OPTIFLUX 2000

More information

Special Reprint. Determination of Vehicle Emissions under Real-world Driving Conditions. Dr. Ulrich Lauff and Rajesh Reddy. Real Driving Emissions

Special Reprint. Determination of Vehicle Emissions under Real-world Driving Conditions. Dr. Ulrich Lauff and Rajesh Reddy. Real Driving Emissions Special Reprint from HANSER automotive 5-6/2017 Dr. Ulrich Lauff and Rajesh Reddy Determination of Vehicle Emissions under Real-world Driving Conditions Real Driving Emissions Juni 2017 Jahrgang 16 15,80

More information

Inazuma Installation and Operating Instructions INAZUMA HD PRO UV-C. High-Performence Duo UVC Lamp

Inazuma Installation and Operating Instructions INAZUMA HD PRO UV-C. High-Performence Duo UVC Lamp Inazuma Installation and Operating Instructions INAZUMA HD PRO 50.000 UV-C High-Performence Duo UVC Lamp Edelstahl-Trommelfilter & High-End-Teichzubehör Index page 1. General Information... 3 1.1. Introduction...

More information

Confirmation: / 22 March 2013

Confirmation: / 22 March 2013 Test report: 936/21205333/A of 06 December 2006 Addendum 936/21220762/A of 04 October 2012 Initial certification: 05 March 2013 Date of expiry: 04 March 2018 Publication: BAnz AT 05 March 2013 B10, chapter

More information

Baying systems TS 8. Height: 1200 mm/1400 mm, depth: 500 mm

Baying systems TS 8. Height: 1200 mm/1400 mm, depth: 500 mm Baying systems TS 8 System accessories Page 537 TS 8 corner enclosures Page 583 TS 8 stainless steel Page 194 TS 8 EMC-shielded Page 200 Material: Enclosure frame, roof, rear panel and gland plates: Sheet

More information

CNG Receptacle of class 0 Of BMT Co. Ltd. Make

CNG Receptacle of class 0 Of BMT Co. Ltd. Make Mobilität Documents regarding Approval of CNG Receptacle of class 0 Of BMT Co. Ltd. Make Approval number: E4-110R-000310-00 Report No: IN110-A0-120037 Dated 16-July-2012 Name of technical service TÜV NORD

More information

Summary of HALT, IPx7 & IP69K testing for AT Series connectors

Summary of HALT, IPx7 & IP69K testing for AT Series connectors S1-15227 Rev. A1 Corp. SINE Systems Corporation 44724 Morley Drive Clinton Twp, MI 48036 Summary of HALT, IPx7 & IP69K testing for AT Series connectors IPx7 (Submersion) PASS Requirements: Acceptance conditions

More information

Grid-integrated Charging with ISO 15118

Grid-integrated Charging with ISO 15118 Grid-integrated Charging with ISO 15118 Advanced Grid: Integration and Testing DER with Communications ESNA, San Diego, 2016-10-05 Stephan Voit, svoit@kngrid.com Agenda > How to do grid integrated charging:

More information

Operating Instructions for Float Flow Meter / Monitor. Model: SWK

Operating Instructions for Float Flow Meter / Monitor. Model: SWK Operating Instructions for Float Flow Meter / Monitor Model: SWK 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...4 5. Operating Principle...4 6. Mechanical Connection...5

More information

Auftrags-Nr.: Order No.: Auftragsdatum: Order date: FT Technologies Ltd. (for add. information see page 3)

Auftrags-Nr.: Order No.: Auftragsdatum: Order date: FT Technologies Ltd. (for add. information see page 3) Prüfbericht-Nr.: 21241719.002 Auftrags-Nr.: Order No.: 21241719 Seite 1 von 9 Page 1 of 9 Kunden-Referenz-Nr.: Client Reference No.: 637965 Auftragsdatum: Order date: 06 October 2017 Auftraggeber: Client:

More information

Daily output in average month 77 m³ Daily values Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Av.

Daily output in average month 77 m³ Daily values Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Av. Parameter Location: Romania, Bârlad (46 North; 27 East) Water temperature: 12 C Required daily output: 40 m³; Sizing for average month Dirt loss: 5,0 % Motor cable: 30 m Pipe type: plastic, drawn/pressed,

More information

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram Data Sheet 403025 Page 1/10 JUMO dtrans p20 Process pressure transmitter Brief description The JUMO dtrans p20 pressure transmitter with HART interface combines maximum precision with easy operation. It

More information

Test report. About the effect of Lambda System Cleaning Products. No

Test report. About the effect of Lambda System Cleaning Products. No Page 1 of 8 Test report About the effect of Lambda System Cleaning Products 0. Client Friedhofstr. 5 67127 Rödersheim-Gronau Germany 1. Task Formulation The effects of the cleaning characteristic of fuel/oil

More information

VIBRATION AND MECHANICAL SHOCK TEST REPORT

VIBRATION AND MECHANICAL SHOCK TEST REPORT Report No. :DH1701190024A-1 Version:A VIBRATION AND MECHANICAL SHOCK TEST REPORT Company :OTO Photonics Inc. Address :9F-5,No. 27, Guanxin Rd., East Dist., Hsinchu City 30072, Taiwan(R.O.C.) Sample Name

More information

User manual. Fiber Probe Coupler FPC-6M. Senary-mirror Fiber Probe Coupler suitable for Nicolet is10(50), Nicolet 6700 & Avatar 360 FTIR spectrometers

User manual. Fiber Probe Coupler FPC-6M. Senary-mirror Fiber Probe Coupler suitable for Nicolet is10(50), Nicolet 6700 & Avatar 360 FTIR spectrometers User manual Fiber Probe Coupler FPC-6M Senary-mirror Fiber Probe Coupler suitable for Nicolet is10(50), Nicolet 6700 & Avatar 360 FTIR spectrometers 1 art photonics GmbH Rudower Chaussee 46 12489 Berlin,

More information

Technical Data Sheet IFS 4000 KC (ENVIROMAG) Electromagnetic flowmeters. ... for water and wastewater measurements

Technical Data Sheet IFS 4000 KC (ENVIROMAG) Electromagnetic flowmeters. ... for water and wastewater measurements Technical Data Sheet KROHNE 05/2004 GR/PRINTO IFS 4000 KC (ENVIROMAG) Electromagnetic flowmeters... for water and wastewater measurements short inlet and outlet runs unaffected by contamination, solids,

More information

INTECH AUGUST QHSE PERFORMANCE

INTECH AUGUST QHSE PERFORMANCE INTECH QHSE PERFORMANCE - MONTHLY QHSE PERFORMANCE Goal Zero Days ( worked days without Lost Time Injury (LTI)) 751 This Month Minor Accidents or Incidents 01 This Month Major Accidents or Incidents 00

More information