PHOENIX CONTACT - 01/2008

Size: px
Start display at page:

Download "PHOENIX CONTACT - 01/2008"

Transcription

1 Exi Solenoid Driver, With Intrinsically Safe Output, LoopPowered, TwoChannel INTERFACE Data Sheet 0289_00_en PHOENIX CONTACT 0/2008 Description The PIEXME2SD/24/65C is a twochannel solenoid driver. It connects a signaling device installed in the safe area to a device located in the Ex area. As the input and output are electrically isolated, the control switch can be located in both cables of the supply circuit. Solenoid valves, alarm modules or other intrinsically safe devices can be connected, and basic electrical equipment, such as LEDs, can be operated. The safety data is designed so that loads can be operated in an IIC group gas. The PIEXME2SD/24/65C solenoid driver does not require a separate power supply, instead it is looped in the circuit.. Properties Twochannel Looppowered Output [EEx ia] IIC 2way electrical isolation The device is an associated item of equipment and must not be installed in potentially explosive areas. When installing and operating the device, the applicable safety directives (including national safety directives), accident prevention regulations, as well as general technical regulations, must be observed. Observe the safety regulations and installation notes on page 4. Make sure you always use the latest documentation. It can be downloaded at A conversion table is available on the Internet at This data sheet is valid for all products listed on the following page:

2 Table of Contents Description... 2 Ordering Data Technical Data Safety Regulations and Installation Notes Structure Basic Circuit Diagram Installation Comparison of Safety Data Calculating a Valve Circuit Ordering Data Solenoid Driver Description Type Order No. Pcs./Pck. Exi solenoid driver, with intrinsically safe output, looppowered, twochannel PIEXME2SD/24/65C Accessories Description Type Order No. Pcs./Pck. Loop wire jumper, 50pos., can be separated, maximum jumpering distance of 60 mm, for jumpering identical inputs and outputs, 0.5 mm², insulation: Black Blue Gray DB BK DB BU DB GY For additional accessories, please refer to the "INTERFACE" catalog from Phoenix Contact. 3 Technical Data Input Input signal Input current 8 V DC V DC (from the control circuit) x I V (output current) Output Output characteristic curve (see Figure on page 3) = 24 V (guaranteed voltage) R i = 370 Ω (internal resistance) Output current (coil current) I V I V = /(R i + R SV ) (see page 7) Response time 20 ms 0289_00_en PHOENIX CONTACT 2

3 Output Characteristic Curve 24 V Output voltage ma Output current I V Figure Output characteristic curve for PIEXME2SD/24/65C General Data Supply voltage range (No separate supply voltage required) Supply voltage type External Power consumption W, approximately; with power adaptation of the output circuit Electrical isolation (input/output) 375 V (peak value according to EN 50020) Test voltage (input/output).5 kv AC, 50 Hz, minute Housing material Polyamide PA, not reinforced Inflammability class according to UL 94 V0 Degree of protection IP20 Color Green Dimensions (width x length x height) 22.5 mm x 99 mm x 4.5 mm Design Terminal block housing for mounting on DIN rails Connection method Plugin screw terminal blocks NAMUR recommendation NE 2 Climatic Data Ambient temperature (operation) Ambient temperature (storage/transport) Permissible humidity (operation) Indicators Status indicator EC Conformance EMC directive 89/336/EEC Ex directive (ATEX) 20 C +60 C 25 C +80 C < 75% (annual average) < 95% (30 days/year, no condensation) Yellow LED (switching state of the input) Yes Yes Safety Data According to ATEX for Intrinsically Safe Circuits Maximum voltage U o Maximum current I o Maximum power P o Gas group Maximum external inductance L o Maximum external capacitance C o Maximum effective voltage U m 27.3 V 96 ma 650 mw 250 V AC IIB 3.5 mh μf IIC 2 mh μf Approvals ATEX X II () GD [EEx ia] IIC, TÜV 00 ATEX 526 UL/CUL U C.D. No. 00T423 (see "UL/CUL Approval" on page 5) 0289_00_en PHOENIX CONTACT 3

4 4 Safety Regulations and Installation Notes 4. Installation and Operation Follow the installation instructions. NOTE: Installation, operation, and maintenance may only be carried out by qualified specialist personnel. When installing and operating the device, the applicable safety directives (including national safety directives), accident prevention regulations, as well as general technical regulations, must be observed. NOTE: The circuits inside the device must not be accessed. Do not repair the device yourself, replace it with an equivalent device. Repairs may only be carried out by the manufacturer. NOTE: The device must not be subject to mechanical strain and/or thermal loads, which exceed the limits described in these operating instructions. NOTE: The device is only designed to meet IP20 protection in a clean and dry environment. In order to provide protection against mechanical or electrical damage, install the device in corresponding housing with a suitable degree of protection according to IEC Where dust is present, install the device in suitable housing with at least IP5x protection. 4.2 Safety Regulations for Installation in Potentially Explosive Areas The device is an associated item of equipment and must not be installed in potentially explosive areas. Regulations for Intrinsically Safe Circuits When carrying out measurements on the intrinsically safe side, observe the relevant regulations regarding the connection of intrinsically safe equipment. Only use devices approved for use in intrinsically safe circuits. If the device has been used in nonintrinsically safe circuits, it must not be used again in intrinsically safe circuits. The module must be clearly labeled as nonintrinsically safe. For the safety data, please refer to the operating instructions and certificates (ECtype examination, other approvals, if necessary). Installation in Areas With a Danger of Dust Explosions The device is not designed for use in areas with a danger of dust explosions. Connection to the intrinsically safe circuit in areas with a danger of dust explosions (zone 20, 2, and 22) is only permitted if the equipment connected to this circuit is approved for this zone (e.g., category D, 2D or 3D). 0289_00_en PHOENIX CONTACT 4

5 4.3 UL/CUL Approval 0289_00_en PHOENIX CONTACT 5

6 5 Structure 7 Installation a PIExMESD/24/65C V DC PIExMESD/24/65C Art.Nr.: NOTE: Electrostatic discharge The device contains components that can be damaged or destroyed by electrostatic discharge. When handling the device, observe the necessary safety precautions against electrostatic discharge (ESD) according to EN and EN The device should only be transported and stored in its original packaging. GELB YELLOW R U0 7. Mounting 4 [EEx ia] IIC [EEx ib] IIC APPROBATIONEN / APPROVALS 99 If the device has been used in nonintrinsically safe circuits, it must not be used again in intrinsically safe circuits. The module must be clearly labeled as nonintrinsically safe. Figure 2 Structure Yellow LED, for indicating the input state 2 COMBICON plugin screw terminal blocks (to release with a flatbladed screwdriver, push out laterally) 3 Direction for removing the screw terminal blocks 4 Metal lock for fixing on the DIN rail Mount the device on a 35 mm DIN rail according to EN The device is calibrated by default upon delivery. For this reason, subsequent calibration of the zero point and final value is not provided. Before startup, check that the solenoid driver is operating and wired correctly, especially with regard to the wiring and labeling of the intrinsically safe circuits. 6 Basic Circuit Diagram Ex area + Safe area IV R i Connecting the Cables Plugin screw terminal blocks; fit the litz wires with ferrules. Install intrinsically safe and nonintrinsically safe cables separately. Permissible cable crosssection: 0.2 mm 2 to 2.5 mm IV R i Figure 3 Basic circuit diagram with connection terminal blocks 0289_00_en PHOENIX CONTACT 6

7 7.3 PreStartup Checklist Before starting the device, make sure that the following conditions have been observed using the technical data: Checkpoint OK Operating conditions have been observed? Correct polarity has been selected for all connections? No impermissibly high voltage in the output circuits during startup? Output load corresponds to the permissible values according to "Output" on page 2? Output circuit grounded at no more than one location? All power supply values correct? 8 Comparison of Safety Data Safety data of: Compare the safety data before connecting a device located in the Exi area to the PIEXME2SD/24/65C. Field devices: U i, I i, P i, L i, C i Solenoid driver: U o, I o, P o, L o, C o For the values for U o, I o, P o, L o, and C o, please refer to "Safety Data According to ATEX for Intrinsically Safe Circuits" on page 3. Exi Requirements: U i U o I i I o P i P o L i + L c L o C i + C c C o (L c and C c depend on the cables/lines used) 9 Calculating a Valve Circuit R I Solenoid driver Figure 4 Equivalent circuit In order to connect a solenoid valve to the device, it is also necessary calculate the measurements in addition to comparing the safety data. R i : Internal resistance of the solenoid driver : Guaranteed voltage of the solenoid driver without load I V : Maximum current that the solenoid driver can supply R C : Maximum permissible cable resistance when connecting the solenoid driver and valve R SV : Effective coil resistance of the solenoid valve (the copper resistance of the coil depends on the temperature) I SV : The current required by the solenoid coil for the valve to pick up U SV : The voltage present at the coil with I SV R SV and U SV depend on the ambient temperature due to the copper resistance. The values for R SV and I SV must be obtained from the valve manufacturer. The values for R i and can be found in the technical data under "Output" on page 2. The permissible cable resistance can be determined according to the following formula: Recommendation: RC = R i R SV I SV I SV R C U SV For R C, an actual cable resistance of +25 Ω should be calculated. In the event of a negative resistance, a successful connection is no longer guaranteed. Function requirements: I V I SV and R C > 0 Ω. R SV Valve A list of suitable valves can be found in the Download Center at _00_en PHOENIX CONTACT GmbH & Co. KG Blomberg Germany Phone: PHOENIX CONTACT P.O.Box 400 Harrisburg PA 7000 USA Phone:

MINI MCR-SL-UI-UI(-SP)(-NC)

MINI MCR-SL-UI-UI(-SP)(-NC) Configurable 3-Way Isolating Amplifier Data Sheet 04/2005 Functions Features The configurable 3-way isolating amplifier MINI MCR-SL-UI-UI(-SP)(-NC) is used to electrically isolate, condition, amplify,

More information

PHOENIX CONTACT

PHOENIX CONTACT Current transformers INTERFACE Data sheet 03359_en_03 PHOENIX CONTACT 20-04-04 Description The PACT Analog current transformers form a complete range of bus-bar, plug-in and winding current transformers

More information

PROTECT SRB s Safety relay modules with intrinsically safe monitoring circuits Ex i L-protection for ATEX zones 1, 2, 21 and 22.

PROTECT SRB s Safety relay modules with intrinsically safe monitoring circuits Ex i L-protection for ATEX zones 1, 2, 21 and 22. PROTECT SRB s Safety relay modules with intrinsically safe monitoring circuits Ex i L-protection for ATEX zones 1, 2, 21 and 22 News 08 PROTECT SRB s Safety relay modules with intrinsically safe monitoring

More information

IB IL 24 PWR IN/F-D IB IL 24 PWR IN/F-D-PAC

IB IL 24 PWR IN/F-D IB IL 24 PWR IN/F-D-PAC IB IL 24 PWR IN/F-D IB IL 24 PWR IN/F-D-PAC Inline Power Terminal With Fuse and Diagnostics Data Sheet 5569C 02/2003 # # $ ' ) The IB IL 24 PWR IN/F-D and IB IL 24 PWR IN/F-D-PAC only differ in the scope

More information

QUINT-PS/24DC/48DC/ 5

QUINT-PS/24DC/48DC/ 5 DC/DC converter with SFB technology, primaryswitched, input: 24 V DC, output: 48 V DC, output current: 5 A Data sheet 104793_en_01 PHOENIX CONTACT 20130503 1 Description QUINT DC/DC converter maximum system

More information

Solenoid Valve Island Type 3965

Solenoid Valve Island Type 3965 Solenoid Valve Island Type 365 for the control of pneumatic actuators General The Type 365 Solenoid Valve Island is a compact solution for the centralized control of pneumatic actuators in chemical and

More information

MINI MCR-SL-UI-UI(-SP)

MINI MCR-SL-UI-UI(-SP) Configurable 3-Way Isolating Amplifier Data Sheet 11/2004 Product Description Features The configurable 3-way isolating amplifier MINI MCR-SL-UI-UI(-SP) is used to electrically isolate, condition, amplify,

More information

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators T 365 EN Type 365 Solenoid Valve Island To control pneumatic actuators Application The Type 365 Solenoid Valve Island is a compact solution for the central control of pneumatic actuators in chemical and

More information

QUINT-PS/48DC/24DC/5. DC/DC converter with SFB technology, primaryswitched, input: 48 V DC, output: 24 V DC, output current: 5 A.

QUINT-PS/48DC/24DC/5. DC/DC converter with SFB technology, primaryswitched, input: 48 V DC, output: 24 V DC, output current: 5 A. DC/DC converter with SFB technology, primaryswitched, input: 48 V DC, output: 24 V DC, output current: 5 A Data sheet 105541_en_00 PHOENIX CONTACT 20130503 1 Description QUT DC/DC converter maximum system

More information

QUINT-PS/24DC/24DC/ 5/CO

QUINT-PS/24DC/24DC/ 5/CO DC/DC converter with SFB technology, dip-coated, primary-switched, input: 24 V DC, output: 24 V DC, output current: 5 A Data sheet 105537_en_01 PHOENIX CONTACT 2014-02-13 1 Description QUT DC/DC converter

More information

QUINT-PS/24DC/24DC/20

QUINT-PS/24DC/24DC/20 DC/DC converter with SFB Technology, primaryswitched, input: 24 V DC, output: 24 V DC, output current: 20 A Data sheet 104791_en_01 PHOENIX CONTACT 20130405 1 Description QUINT DC/DC converter maximum

More information

NAMUR FLANGE: With integrated exhaust air recirculation Ordering information

NAMUR FLANGE: With integrated exhaust air recirculation Ordering information 00 TÜV-approval based on IEC 6 08, DIN V 9 Approvals: DIN EN 6/9 DVGW, group Rm and EN 6 Valves for safety systems to SIL or AK 7 / Directional control valves Actuation: electromagnetic Directly controlled

More information

E II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc

E II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc 900/77-80-094-001 158877 For the intrinsically safe operation of a wide range of devices, such as HART transmitters, solenoid valves, sensors, zero-potential contacts and many more compact, space-saving

More information

QUINT-PS/24DC/24DC/10

QUINT-PS/24DC/24DC/10 DC/DC converter with SFB Technology, primaryswitched, input: 24 V DC, output: 24 V DC, output current: 10 A Data sheet 104790_en_01 PHOENIX CONTACT 20130405 1 Description QUINT DC/DC converter maximum

More information

ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application

ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application 2-3.1 ATC 510/520/525 for wall-mounting Application The ATC 510/5205/525 is a modern microprocessor-based (PID) control device featuring easy handling and a digital display. The clear design of the operator

More information

MINI-DC-UPS/24DC/2. Extract from the online catalog. Order No.:

MINI-DC-UPS/24DC/2. Extract from the online catalog. Order No.: Extract from the online catalog MINI-DC-UPS/24DC/2 Order No.: 2866640 Uninterruptible power supply with integrated power supply unit, 2 A, in combination with MINI-BAT/24/DC 0.8 AH or 1.3 AH Commercial

More information

DC/DC converters - MINI-PS DC/ 5-15DC/

DC/DC converters - MINI-PS DC/ 5-15DC/ Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid

More information

Material pressure (bar) (Cv (US) kv x 1,2 Seat. N/en

Material pressure (bar) (Cv (US) kv x 1,2 Seat. N/en 00 / poppet valves electromagnetic actuated, directly controlled, / NPT or flanged with NAMUR Interface TÜV-approval based on IEC 6 8, DIN V Valves for safety systems up to SIL Solenoid valve also suitable

More information

Fieldbus Segment Protector F2-SP-IC* Features. Assembly. Function. Connection. Zone 2 Div. 2

Fieldbus Segment Protector F2-SP-IC* Features. Assembly. Function. Connection. Zone 2 Div. 2 Fieldbus Segment Protector Features Assembly 4... 10 outputs Ex ic (FISCO or Entity) or non-incendive (Div 2) Advanced fault isolation at the spur Segment Protector in Zone 2/Div. 2 Instruments in Zone

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. TEIP11 I/P signal converter for standard signals

ABB MEASUREMENT & ANALYTICS DATA SHEET. TEIP11 I/P signal converter for standard signals ABB MEASUREMENT & ANALYTICS DATA SHEET TEIP11 I/P signal converter for standard signals 2 TEIP11 I/P SIGNAL CONVERTER FOR STANDARD SIGNALS DS/TEIP11-EN REV. D Flow in air pressure Proven and reliable concept

More information

Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage

Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage Data Sheet Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage Reliable through well-proven concept - More than 1,000,000 units in use Compact

More information

QUINT-PS/24DC/24DC/10/CO

QUINT-PS/24DC/24DC/10/CO DC/DC converter with SFB technology, dipcoated, primaryswitched, input: 24 V DC, output: 24 V DC, output current: 10 A Data sheet 105538_en_01 PHOENIX CONTACT 20140213 1 Description QUT DC/DC converter

More information

MFH MOFH JMFH JMFDH NVF3 MUFH VOFD VOFC VSNC VUVS

MFH MOFH JMFH JMFDH NVF3 MUFH VOFD VOFC VSNC VUVS Solenoid coils Solenoid coils Product range overview Version Type For valve series Page/ Internet MFH MOFH JMFH JMFDH NVF3 MUFH VOFD VOFC VSNC VUVS F solenoid coil MSF VACF 3 N solenoid coil VACN-N 6 N

More information

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN Electropneumatic Converters i/p Converters Type 6111 Fig. 1 Type 6111 in standard version Fig. Type 6111 mounted on a supply air manifold Fig. 3 Type 6111 in field enclosure Mounting and Operating Instructions

More information

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS 4751 Technical brochure Features Ex ll 1G EEx ia llc T4 - T6 in compliance with ATEX 100a Applicable

More information

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19 , IECEx EPS 16.0030X Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19 Device with II 2G/D Ex approval Geräte mit II 2G/D Ex Zulassung Appareils avec mode de protection II 2G/D Ex

More information

PTB 14 ATEX 2023 X, EPS 16 ATEX 1046 X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

PTB 14 ATEX 2023 X, EPS 16 ATEX 1046 X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10 PTB 14 ATEX 2023 X, EPS 16 ATEX 1046 X Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10 Device with II 2G/D Ex approval Geräte mit II 2G/D Ex Zulassung Appareils avec mode de protection

More information

Solenoid coils VACF Type codes

Solenoid coils VACF Type codes Solenoid coils VACF Type codes VACF B B2 1A Type VACF Solenoid coil, F series Solenoid coil type A B Width 30 mm, for 8 mm armature tube Width 22 mm, for 8 mm armature tube A1 Connection pattern type A,

More information

TZIM. Electropneumatic Analog Positioner 10/ EN

TZIM. Electropneumatic Analog Positioner 10/ EN TZIM Electropneumatic Analog Positioner EP001XA.tif Q Convenient, simple design Q Easy to handle Q User-friendly operation, easy to understand Q Reliable concept, I/P conversion through the 500,000 times

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics /2-, 5/2-5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics /-, 5/- 5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx

More information

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10 , IECEx PTB 14.0049X Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10 Device with II 2G/D Ex approval Geräte mit II 2G/D Ex Zulassung Appareils avec mode de protection II 2G/D Ex

More information

Pressure transmitter JUMO dtrans p02

Pressure transmitter JUMO dtrans p02 JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 609 Fulda, Germany Postal address: 605 Fulda, Germany Phone: +49 661 600-0 Fax: +49 661 600-607 e-mail: mail@jumo.net Internet: www.jumo.net JUMO

More information

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators Fig. 1 Type 3761 Positioner Mounting and Operating Instructions EB 8386 EN Edition July 2007 Contents Contents Page 1 Design and

More information

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1 INLINE Flow sensor for hazardous area II G/D - II D - II GD - I M Type SE0 Ex can be combined with... Flow meter with NAMUR or NPN/PNP output signal Mounting, dismounting of electronics by a Quarter-Turn

More information

Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage

Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage Data Sheet Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage Reliable through well-proven concept - More than 1,000,000 units in use

More information

HERION SERIES Indirect solenoid actuated soft seal

HERION SERIES Indirect solenoid actuated soft seal HERION 9700 SERIES Indirect solenoid actuated soft seal spool valves with NAMUR interface /, 5/ - G/ For single and double acting actuators Crossover-free switching, switchover function guaranteed even

More information

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518 3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics Type 658 standard standard High flow-rate capacity Reduced power consumption Single or manifold mounting Standard-, EEx m and EEx i versions

More information

Solenoid Valves Type 3963

Solenoid Valves Type 3963 Mounting and Operating Instructions Solenoid Valves Type 3963 Fig. 1 General Assembly, commissioning and operation of these devices may only be performed by experienced personnel. Proper shipping and appropriate

More information

Material pressure (bar) (Cv (US) kv x 1,2 Seat

Material pressure (bar) (Cv (US) kv x 1,2 Seat 00 / way poppet valves electromagnetic actuated, directly controlled G /, / NPT or flanged with NAMUR Interface TÜV-approval based on IEC 6 08, DIN V 9 Valves for safety systems up to SIL Solenoid valve

More information

Pneumatic or Electropneumatic Positioner for Rotary Actuators Type Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Pneumatic or Electropneumatic Positioner for Rotary Actuators Type Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN Pneumatic or Electropneumatic Positioner for Rotary Actuators Type 3761 Fig. 1 Type 3761 Positioner Mounting and Operating Instructions EB 8386 EN Edition June 2004 Contents Contents Page 1 Design and

More information

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve Type 367 Solenoid Valve Application Solenoid valve for controlling pneumatic linear actuators with NAMUR rib according to IEC 60534 or pneumatic rotary actuators with NAMUR interface according to VDI/VDE

More information

Measuring insert for resistance thermometer Model TR10-A

Measuring insert for resistance thermometer Model TR10-A Electrical temperature measurement Measuring insert for resistance thermometer Model TR1-A WIKA data sheet TE 6.1 for further approvals see page 6 Applications Replacement measuring insert for servicing

More information

FICHA TÉCNICA DE PRODUTO

FICHA TÉCNICA DE PRODUTO FICHA TÉCNICA DE PRODUTO PRODUCT DATASHEET HMI Automação e Instrumentação, Lda. Rua dos 5 Caminhos, nº 570 4780-382 Santo Tirso PORTUGAL Web: www.hmi.pt Tel. +351 252 850 501 Fax. +351 300 013 487 Email:

More information

Operating Instructions. VEGASWING 61, 63 with oscillator SW E60N (EX)

Operating Instructions. VEGASWING 61, 63 with oscillator SW E60N (EX) Operating Instructions VEGASWING 61, 63 with oscillator SW E60N (EX) Contents Contents Safety information... 2 Note Ex area... 2 1 Product description... 3 2 Function and application... 4 2.1 Principle

More information

Series 3730 Electropneumatic Positioner Type

Series 3730 Electropneumatic Positioner Type Series 3730 Electropneumatic Positioner Type 3730-1 Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating, automatic adaptation to valve and

More information

KINAX SR 709 Transmitter for position feedback

KINAX SR 709 Transmitter for position feedback KINAX SR 709 Transmitter f position feedback Position transmitter with NAMUR valve fitting Application The position feedback transmitter KINAX SR 709 (Fig. 1 and 2) is used to measure and transmit linear

More information

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0. DMK P Industrial Pressure Transmitter Pressure Ports With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 60 bar up to 0... 400 bar Output signals

More information

Limit switch attachments DAPZ

Limit switch attachments DAPZ Type codes DAPZ SB M 250AC DR AR Type DAPZ Limit switch attachment Specification SB Sensor box Measuring principle I M Inductive Electrical, micro switch Operating voltage 25DC 30DC 250AC 8 V DC 30 V DC

More information

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter For High Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 bar up to 0... 600

More information

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement Point level measurement - RF Capacitance switches Pointek CLS200 - Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level and material detection switch with optional rod/cable

More information

KINAX SR 709 Transmitter for Position Feedback

KINAX SR 709 Transmitter for Position Feedback Position transmitter with NAMUR valve fitting Application The position feedback transmitter KINAX SR 709 (Fig. 1 and 2) is used to measure and transmit linear displacement (stroke) on various types of

More information

Electro-pneumatic control valves

Electro-pneumatic control valves Electropneumatic control valves Visit our website for further information www.crouzet.com 9 Electropneumatic miniature solenoid Miniature solenoid valves Terminals Wires Connector LED indicators Valve

More information

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram Data Sheet 403025 Page 1/10 JUMO dtrans p20 Process pressure transmitter Brief description The JUMO dtrans p20 pressure transmitter with HART interface combines maximum precision with easy operation. It

More information

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot SPOOL VALVES operated / to / tapped body and NAMUR for integrated pilot ATEX /-/ Series - FEATURES The valves offer environmental protection against the ingress of liquids, dusts or other foreign matter

More information

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm Industrial Pressure Transmitter Pressure Ports With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 60 bar up to 0... 400 bar Output signals

More information

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter. TEMATEC GmbH Postal address:: Postbox 6 House address Löhestr. 7 5759 Hennef 577 Hennef Fon (+49) 0 4-87 0-0 Fax (+49) 0 4-87 0-0 http: // www.tematec.de e-mail: team@ tematec.de TEMATEC GmbH Data Sheet

More information

Ex m Solenoid Operator Type 0519

Ex m Solenoid Operator Type 0519 nass magnet GmbH Eckenerstrasse 4-6 D-30179 Hannover Doc. No. 113-720-0002 Revision No. 2 01.06.2015 Ex m Solenoid Operator Type 0519 Operating Instructions Dear Customer! To ensure the function and for

More information

Limit Switch Type 4747

Limit Switch Type 4747 Limit Switch Type 4747 Ex d flameproof enclosure with inductive or mechanical contacts for linear actuators or rotary actuators acc. to VDI/VDE 3845 General The Type 4747 Limit Switch issues an electrical

More information

3/2 Way Pilot Valve 3/2 Way Solenoid Valve 1 /4" and 1 /2" 5/2 Way Solenoid Valve 1 /4" 6/2 Way Solenoid Valve 1 /4" 5/3 Way Solenoid Valve 1 /4"

3/2 Way Pilot Valve 3/2 Way Solenoid Valve 1 /4 and 1 /2 5/2 Way Solenoid Valve 1 /4 6/2 Way Solenoid Valve 1 /4 5/3 Way Solenoid Valve 1 /4 /2 Way Pilot Valve /2 Way Solenoid Valve 1 /" and 1 /2" 5/2 Way Solenoid Valve 1 /" 6/2 Way Solenoid Valve 1 /" 5/ Way Solenoid Valve 1 /" General The solenoid valves consist of one or two /2 way pilot

More information

Accessories Cable glands

Accessories Cable glands Accessories Cable glands 235 Technical data Cable glands Brass hexagon cable gland Brass sealing cable gland Material: Brass, nickel-plated Gasket: Soft rubber Protection type IP 54 Additional information:

More information

97100 NAMUR. Technical data

97100 NAMUR. Technical data 9700 NAMUR /2-, /2- and / Directional control valves Actuation: electromagnetic Indirectly controlled soft seal spool valves Port size: G /4, /4 NPT NAMUR Interface For single and double operated actuators

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview. Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,

More information

SIRIUS 3RU2 Thermal Overload Relays

SIRIUS 3RU2 Thermal Overload Relays Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors. The overload relay can be connected directly to

More information

Electronic Circuit Breaker ESS20-0..

Electronic Circuit Breaker ESS20-0.. Electronic Circuit Breaker ES-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode

More information

Power Plugs for Proportional Valves (12 volt supply)

Power Plugs for Proportional Valves (12 volt supply) VICKERS Accessories Plugs for Proportional Valves ( volt supply) EHH-AMP-7-D/G-* Series For use with valve types: KDGV-(S)-GP7-6* KTGV-(S)-GP7-6* KCG-/6/8-GP-* KX(C)G-6/8-GP-* KDG5V-5/7/8-GP-* CMX***-E-G

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,

More information

JUMO dtrans p20 DELTA

JUMO dtrans p20 DELTA Data Sheet 403022 Page 1/9 JUMO dtrans p20 DELTA Differential pressure transmitter Brief description The JUMO dtrans p20 DELTA differential pressure transmitter with HART interface combines maximum precision

More information

Magnetic switch For bypass level indicators Model BGU for nuclear power plants

Magnetic switch For bypass level indicators Model BGU for nuclear power plants Level measurement Magnetic switch For bypass level indicators BGU for nuclear power plants KSR data sheet BGU for NPP Applications Magnetic switches for detecting the limits of filling levels in bypass

More information

EPS 16 ATEX 1121 X, IECEx EPS X Solenoid coil Type 06xx Magnetspule Typ 06xx Bobine magnétique Type 06xx. Operating Instructions

EPS 16 ATEX 1121 X, IECEx EPS X Solenoid coil Type 06xx Magnetspule Typ 06xx Bobine magnétique Type 06xx. Operating Instructions , IECEx EPS 16.0053X Solenoid coil Type 06xx Magnetspule Typ 06xx Bobine magnétique Type 06xx Device with II 2G/D Ex approval Geräte mit II 2G/D Ex Zulassung Appareils avec mode de protection II 2G/D Ex

More information

Operating Instructions

Operating Instructions Operating Instructions Terminal Box > 8150/1 > 8150/2 Contents 1 Contents 1 Contents...2 2 General Information...2 2.1 Manufacturer...2 2.2 Operating Instructions Information...2 3 Intended Use...2 4 Safety

More information

RSDE10 / RSDE20 (Contrac) Electrical Linear Actuator

RSDE10 / RSDE20 (Contrac) Electrical Linear Actuator Contents Data Sheet Rev. A RSDE10 / RSDE20 (Contrac) Electrical Linear Actuator For continuous positioning, In explosion-proof design, Rated force 10 kn / 20 kn (2200 lbf / 4400 lbf) Electrical actuator

More information

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm DMP P Industrial Pressure Transmitter Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Industrial

More information

USER s MANUAL 1. GENERAL INFORMATION 2. PRODUCT IDENTIFICATION

USER s MANUAL 1. GENERAL INFORMATION 2. PRODUCT IDENTIFICATION 1. GENERAL INFORMATION The MICROSOL intrinsic safety solenoid valves produced by Fluid Automation Systems SA are dedicated to piloting fluids in explosive atmospheres according to the ATEX 94/9/CE directive,

More information

SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function)

SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function) SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function) brass body, NAMUR, / 0 0 /-/ Série FEATURES The monostable spool valves have TÜV certified IEC 608 Functional

More information

*-JBSC-* Fieldbus junction box with integrated short-circuit current limitation

*-JBSC-* Fieldbus junction box with integrated short-circuit current limitation Fieldbus Segment Protector Fieldbus junction box with integrated short-circuit current limitation Type code see overleaf Connection Shielding variations Main cable Trunk N Fieldbus distributor with individually

More information

Direct-acting 3/2 way plunger valve

Direct-acting 3/2 way plunger valve Direct-acting 3/2 way plunger valve Direct-acting, compact valve with diameter of up to DN 2.5 Vibration-proof, bolted coil system Banjo threaded connection for direct mounting on pneumatic valves Type

More information

Electronic Limit Switch Type

Electronic Limit Switch Type Electronic Limit Switch Type 3738-20 with optional solenoid valve for on/off rotary actuators Application Electronic limit switch for on/off applications to indicate the end position of rotary actuators.

More information

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130 Operating Manual (Edition 04/2004) sinamics Braking Module / Braking Resistor SINAMICS G130 04/04 Contents Contents 1 Safety Information 1-1 2 General 2-1 3 Mechanical Installation 3-1 4 Connection 4-1

More information

Magnetic switch For bypass level indicators Model BGU

Magnetic switch For bypass level indicators Model BGU Level measurement Magnetic switch For bypass level indicators BGU KSR data sheet BGU Applications Magnetic switches for detecting the limits of filling levels in bypass level indicators Chemical and petrochemical

More information

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview. Overview Configuration is an inverse frequency shift capacitance continuous It is ideal for standard industrial applications in chemical, hydrocarbon processing, food and beverage and mining, aggregate

More information

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 40

More information

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial TEMATEC GmbH Postal address: House address Fon (+49) 0 4-870-0 Postbox 6 Löhestr. 7 Fax (+49) 0 4-870-0 http: // www.tematec.de 5759 Hennef 577 Hennef e-mail: team@tematec.de TEMATEC GmbH Data Sheet DMP

More information

Control and Terminal Box Type A21-**-*****

Control and Terminal Box Type A21-**-***** e pd Control and Terminal Box Exepd GmbH i_park TAUBERFRANKEN Building 23 Becksteinerstrasse 100 97922 Lauda-Königshofen Germany Phone: ++49 (0) 9343 627055-0 Fax: ++49 (0) 9343 627055-99 Mail: info@exepd.de

More information

Technical Documentation

Technical Documentation Technical Documentation Product manual Holding brake controller Document: 0198441113316 Edition: V1.00, 03.2006 Important information The drive systems described here are products for general use that

More information

Level Measurement based on Archimedes Principle. Device Description

Level Measurement based on Archimedes Principle. Device Description Level Measurement based on Archimedes Principle BA Device Description Contents 1 IDENTIFICATION...4 1.1 Supplier/manufacturer...4 1.2 Product type...4 1.3 Product name...4 1.4 Issue date...4 1.5 Version

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS RTECK terminal boxes RTKB series IEC Ex EX010 TECHNICAL FILES CONTENTS: 1) Contents 2) General information 3) Safety information 4) Conformity to standards 5) Function 6) Technical

More information

-V- New. Valve series VOFC. 2009/08 Subject to change Internet:

-V- New. Valve series VOFC. 2009/08 Subject to change Internet: Valve series VOFC 2009/08 Subject to change Internet: www.festo.com/catalogue/... 159 Solenoid valves VOFC Key features General information The valves in the VOFC series are special 3/2-way and 5/2-way

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExBGL2D LED BEACON For use in Flammable Gas and Dust Atmospheres BExBGL2D 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGIZED POTENTIAL

More information

EPS 16 ATEX 1111X, IECEx EPS X. Operating Instructions. Solenoid coil Type ACP016 Magnetspule Typ ACP016 Bobine magnétique Type ACP016

EPS 16 ATEX 1111X, IECEx EPS X. Operating Instructions. Solenoid coil Type ACP016 Magnetspule Typ ACP016 Bobine magnétique Type ACP016 Solenoid coil Type ACP016 Magnetspule Typ ACP016 Bobine magnétique Type ACP016 Device with II 2G/D Ex approval Geräte mit II 2G/D Ex Zulassung Appareils avec mode de protection II 2G/D Ex Operating Instructions

More information

Positioners Converters Limit Switches Position Transmitters Solenoid Valves Accessories. Selection and Application

Positioners Converters Limit Switches Position Transmitters Solenoid Valves Accessories. Selection and Application Positioners Converters Limit Switches Position Transmitters Solenoid Valves Accessories Selection and Application Associated s T 8355 EN ff. Edition January 2010 Information Sheet T 8350 EN Positioners,

More information

9.6 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

9.6 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax , E X - C O N T R O L S T A T I O N S Moulded plastic Version for Zone 1 and Zone 21 Even under the most adverse conditions, CEAG control stations can be used and operated reliably. The enclosures consist

More information

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm DMP P Industrial Pressure Transmitter Pressure Ports And Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO from 0... 00 mbar up

More information

Data Sheet DS/NGB-EN Rev. B. Multi barriers. Measurement made easy. Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1

Data Sheet DS/NGB-EN Rev. B. Multi barriers. Measurement made easy. Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1 Data Sheet DS/NGB-EN Rev. B Multi barriers Measurement made easy Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1 Change from two to one column Multi barriers Change from one to two columns

More information

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06 www.atos.com Table TF040-2/E Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06 A B DHRZO-A-012/25 A B DHRZA-A-010/25 DHRZ* are

More information

Our policy is one of continued research and development. We therefore reserve the right

Our policy is one of continued research and development. We therefore reserve the right 970 Namur /-, /- and /-Directional control valves Electromagnetic indirectly controlled soft seal spool valves G /4, /4 NPT NAMUR-interface For single and double operated actuators Exhaust air recirculation

More information

Type Electronic Limit Switch

Type Electronic Limit Switch Type 3738-20 Electronic Limit Switch With optional solenoid valve Application Electronic limit switch for on/off applications to indicate the end position. Optionally with integrated solenoid valve. Special

More information

Product specification

Product specification Product specification Measuring range of 4 mm Features Non-contacting displacement measurement based on the eddy-current principle System length: 5 m or 10 m with ATEX approval Temperature range: -50 C

More information

IB IL 24 SEG/F. Function. INTERBUS Inline Segment Terminal With Fuse. Data Sheet 5656B

IB IL 24 SEG/F. Function. INTERBUS Inline Segment Terminal With Fuse. Data Sheet 5656B INTERBUS Inline Segment Terminal With Fuse Data Sheet 5656B 02/2001 # $ # $ ) This data sheet is intended to be used in conjunction with the Configuring and Installing the INTERBUS Inline Product Range

More information

PPT 802, Proximity Probe Transducer System

PPT 802, Proximity Probe Transducer System PPT 802, Proximity Probe Transducer System PPH 080 : Proximity Probe Head PEC 036 : Probe Extension Cable PRD 020 : Proximity Probe Driver Feature Non-contacting measurement system based on eddy current

More information