2 Table Of Contents Wire 00 Vacuum Top Adjustment Auxiliary Coil General Guide Mechanical Bottle Bottom Drawout and Assemblies Assemblies Harnesses Assemblies Guide Terminal information 800 Bottle Contactor Interlocks Tool Amp Latch Assemblies Assemblies Kits Assemblies Contactors Parts CRI9B, C & D Renewal Pals Bulletin ~ rhese instructions do not purport to cover all details or variations in equipment for every possible contingency to be met in connection with nstallation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the Purchaser's purposes, the matter should be referred to the nearest GE SaIA!: Offi"A
3 CRI9B, C & D Renewal Parts Bulletin General Information This renewal parts bulletin will provide the proper identification of standard parts which may be required for the maintenance of CR9B & D (00A) and CR9C (800A) Vacuum Limitamp contactors. iboth the complete contactors and required renewal parts are shown as catalog numbers and are supported by photographs. Catalog numbers identified in this bulletin may not be the same as those parts on the original equipment. The renewal part catalog numbers are shown in kit form. It is the intent of this bulletin to give our customers a quick and accurate way to identify parts required for normal maintenance of the Vacuum Limitamp contactors. Unless otherwise stated, all of the parts shown in the bulletin are compatible with the contactors manufactured since 98. Since contactors are supplied to meet specific customer control and distribution requirements, certain replacement parts not listed in this publication may occasionally be required. Please refer to the factory for these requests. In these situations, please provide a complete description of the part, along with the complete data shown on the contactor nameplate that is affixed to the top of the contactor. For pricing and availability of parts shown in this bulletin, contact your nearest GE sales office. ~ttention should be g iven to forecasting lour particular renewal parts requirements :0 ensure on-site availability of the specific )arts as required for normal maintenance ~nd proper operation of your equipment. ro maintain maximum operating efficiency nd reliability of your equipment, genuine E renewal parts are recommended.
4 CRI.9.B, C & D Renewal Pal'fs Bulletin 00A and 800A Vacuum Contactor Fig. Contactors can be identified by their catalog number, located on the nameplate on the top of the contactor. Note: 00A contactor shown in photo 00 Amp Contactor 800 Amp Contactor CR9B & D Vacuum contactors are designed for equipment used in starting AC motors with line voltages from 000-Volts to a maximum of 700-Volts, transformer feeders, and other medium voltage control equipment Contactor Bracket and Pin Assembly Control Wire Harness Plug Bracket and Socket Assembly (not shown) CR9C Vacuum contactors are designed for equipment used in starting AC motors with line voltages from 000-Volts to a maximum of O00-Volts, transformer feeders, and other medium voltage control equipment BG See Fig. BG Contactor Catalog Number System + Voltage for contactor main coil is always 0/ VOC * The sum of normally open, normally closed, and late opening normally closed ~ contacts must be a multiple of five (). Each interlock block contains five () contacts. A contactor may contain a maximum of four () blocks, two () being the maximum on either side. Only five () late opening normally closed contacts are available on a contactor. Typical contactor number: CR9Bll0LO00U
5 CR9.:E, C& D Fenewal Parts Bulletin Fig. Fig. Coil Assembly ~cription rn9b rn9c, & D, 00 arrp contactor 800 arrp contactor pan NurTJer D78~ D780GR Note".00\ coil shown in pooto Fig. Fig..e \~' 00 o o Vacuum Bottle Assembly Guide Assembly ption Part NurrtJer - O70000GR' CR9B & D, 00 a"'p contactor Part NurTiJer O7reCXR' CR9C, 800 an-p contactor
6 CRI9.B, C & D Renewal Parts Bulletin Fig. 6 Fig. 7 ~ Contactor Top Assembly Contactor Adjustment Tool Kit CR98 & D, 00 amp contactor D78008GR CR98 & D, 00 amp contactor 0A900DCGl CR9C,800 ampcontactor D780GR CR9C, 800 amp contactor 0A900DCG Note: 00A top assembly shown in photo Note: 00A tool kit shown in photo Fig. 8 Mechanical latch Assembly 0/ VDC VDC C67989GRA C67989GRB
7 CRI9.B, C & D Renewal Parts Bulletin Fig Amp Block 00 Amp Block Auxiliary Interlocks The table below lists all possible combinations of auxiliary interlocks within a single block. Select the contact arrangement desired and add the suffix letters to the appropriate part number (i.e.. C679809GRP). Contactor CR9B & D, 00 Amp contactor CR9C, 800 Amp contactor C C6798- Suffix GlRP GRP GRP GRP GRP G6RP G7RP GBRP G9RP GlORP GllRP NO NC LONG Suffix GRP GRP GRP GRP G6RP G7RP G8RP G9RP G0RP GRP NO NC LONG
8 Drawout Contactor (CR9D) Parts ~ CR9B, C & D Renewal Parts Bulletin Fig. 0 Fig. Bottle Guide Bottle Guide Assembly Bottom Terminal Assembly D escription CR9B & D, 00A contactor CR9C, 800 A contactor Note: 00A top assembly shown in photo D780GR D7807GR CR9B, 00A contactor CR9D,00A drawout contactor CR9C, 800A contactor Note: 00A terminal parts shown in photo D78008GR D78008GR D780GR Fig.
CR193 B,C,D and E Vacuum Limitamp * Contactors
GE Industrial Solutions CR19 B,C,D and E Vacuum Limitamp * Contactors Renewal Parts Bulletin Table of Contents General Information... Contactor Matrix... 4 Mounting Plates, Pull Handle, Interlock Driver
More informationCR193 Vacuum Limitamp* Contactors
GE Electrical Distribution GEH-5306C Maintenance Instructions CR193 Vacuum Limitamp* Contactors Contents Section 1 Introduction... 3 General... 3 Section 2 Description... 4 Principle of Operation... 4
More informationBBC. Renewal Parts. I-T-E Low-Voltage Power Circuit Breakers
BBC BROWN BOVERI RP 6..2.8-2C Renewal Parts I-T-E Low-Voltage Power Circuit Breakers Type K-000, 4000, 0008, and 40008 Stationary and Drawout Mounted 000 and 4000 Amperes 600 Volts RP 6..2.8-2 Page 2 Table
More informationwww. ElectricalPartManuals. com BBC Brown Boveri Electric Renewal Parts 1-T -E Low-Voltage Power Circuit Breakers
i BBC BROWN BOVERI Type LK and LKE 800 thru 4200 Amperes Type LKD 800 and 1600 Amperes 600 Volts RP 6118A Renewal Parts 1-T -E Low-Voltage Power Circuit Breakers Brown Boveri Electric RP 6118-1A Page 2
More informationLow Voltage WavePro TM and EntelliGuard TM Circuit Breakers Remote Racking Operator
GE Consumer & Industrial Electrical Distribution Operation & Maintenance Manual GEK-99986 Catalog # WPEGRRLV 115 VAC, 60/50 Hz Low Voltage WavePro TM and EntelliGuard TM Circuit Breakers Remote Racking
More informationDEF-002. Vacuum Limitamp Medium Voltage Motor Control. wal Parts
DEF-002 Vacuum Limitamp Medium Voltage Motor Control wal Parts Table of Contents Introduction... 1 Reference Publications... 1 Parts Identification... 1 High-Voltage Contactor Nameplate... 1 Limitamp
More informationGEF Renewal Pans. low Vohage Power Circuit Breakers. Type AKR-30S and AKRU-30S. www. ElectricalPartManuals. com
-- GEF-6005 Renewal Pans low Vohage Power Circuit Breakers Type AKR-30S and AKRU-30S INTRODUCTION This manual provides a listing of the parts and assemblies that are availle as replacement parts for low
More informationSection 18. Medium Voltage Equipment. BuyLog Catalog 18-1
MV One Line...18-2 Motor Control Medium Voltage (Limitamp ) Introduction, Features, Types, Options, References...18-3 Specifications, Ratings, Equipment Reference Publications...18-4 Product Scope...18-5
More informationAmpgard medium voltage motor control renewal parts
Technical Data TD020001EN Contents Description Page General information.... 2 3 400A starter design.... 4 9 800A starter design.... 10 15 Control and potential transformers.... 16 Current transformers....
More informationInstruction sheet WARNING. October, 2014
E8700-A064-T003-A6-LCN0 Page of 6 October, 04 WARNING Hazardous voltage Can cause death or serious injury. Disconnect main power and control voltages before installation or maintenance on the equipment.
More informationGEK41931B INSTRUCTIONS MULTI-CONTACT AUXILIARY RELAYS TYPE HFA73K. GE Protection and Control 205 Great Valley Parkway Malvern, PA
GEK41931B INSTRUCTIONS MULTI-CONTACT AUXILIARY RELAYS TYPE HFA73K GE Protection and Control 205 Great Valley Parkway Malvern, PA 19355-1337 GEK-41931 CONTENTS PAGE DESCRIPTION 3 APPLICATION 3 TABLE I 3
More informationInstallation Sheet January, 2016 Supersedes February, 2013
s Installation Sheet January, 016 Supersedes February, 013 E87010-A0104-T003-A6-CLM0 Lighting and Heating Contactor 30 Amp, 3, 4, 5 Pole Magnetically Latched Description Magnetically latched CLM lighting
More informationRENEWAL PARTS AK-2-15 AK-2-25 AK-3-25 AKF-2-25 AK-2A-15 AK-2A-25 AK-3A-25 AKF-2A-25 AKU-2-25 AKU-3-25 AKU-2A-25 AKU-3A-25
Data ubject to change without notice. RENEWAL PARTS POWER CIRCUIT BREAKERS TYPES 225 AMP FRAME SIZE 00 AMP FRAME SIZE GEF-449G Supersedes GEF-449F AK-2-5 AK-2-25 AK-3-25 AKF-2-25 AK-2A-5 AK-2A-25 AK-3A-25
More informationPage 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut
Page 1 Supersedes Renewal Parts Data 33-790-1G pages 1-20 dated December, 1988 Mailed to: C, D, E/33-700 Westinghouse DS and DSL Low Voltage Power Circuit Breakers and Cell Parts Contents Pages DS Breaker
More informationT300MVi JK OEM POWER CELLS MEDIUM VOLTAGE VACUUM CONTACTOR. Reliability in motion. Reliability in motion
MEDIUM VOLTAGE VACUUM CONTACTOR T300MVi JK OEM POWER CELLS Reliability in motion Reliability in motion 400 AMPERE AT 2300-6600 VOLTS (7200 VOLT MAX) DRAWOUT AND FIXED APPLICATIONS JK OEM PART NUMBER DESCRIPTION
More informationwww. ElectricalPartManuals. com MAGNETIC TIME RELAYS GENERAL. ELECTRIC INSTRUCTIONS *IC *Also identified with prefix CR instead of IC.
NSTRUCTONS MAGNETC TME RELAYS *C2820-054 *Also identified with prefix CR instead of C. GENERAL. ELECTRC GEH-85F NTRODUCTON The CR2820-054 relay is a d-e operated relay. t may be applied as an instantaneous
More informationwww. ElectricalPartManuals. com Type AM Magne-Biast Circuit Breakers RENEWAL PARTS
RENEWAL PARTS Ordering Instructions 1. Always specify the complete nameplate data of the breaker. 2. Specify the quantity, catalog number (if listed), reference number (if listed) description, and this
More informationRENEWAL PARTS I C302AA A-2 300V AB A-4800V A C A -SOOOV PARTS RECOMMENDED FOR NORMAL STOCK
NGrE: RENEWAL PARTS IC0A HIGH VOLTAGE CONTACTORS I C0AA 00A 00V AB00A800V A C 00A SOOOV PARTS RECOMMENDED FOR NORMAL STOCK The current is identified by the number following the voltage letter in the IC
More informationPower Break Circuit Breakers
Draw Out 800-4000 Amperes GEH-46988 Installation Instructions Power Break Circuit Breakers POWER BREAK Draw Out Circuit Breaker (SOOA 4000A) DESCRIPTION Types TC, and THC Power Break draw out circuit breakers
More informationOperation and Maintenance Manual
DEH-41482 GE Energy Industrial Solutions Low Voltage Switchgear Remote Racking Operator For AKR Circuit Breakers Cat. # AKREGRR 115 VAC, 60/50 Hertz Operation and Maintenance Manual TABLE OF CONTENTS Section
More informationInstallation Sheet January, 2016 Supersedes June 2013
s Installation Sheet January, 016 Supersedes June 01 E87010-A0105-T00-A6-CLM0 Lighting and Heating Contactor 60, 100, 00 Amp,, 4, 5 Pole Magnetically Latched Description Magnetically latched CLM lighting
More informationCD5--- CA4--- CD6---- CB2---- CB4---- PARTS RECOMMENDED FOR NORMAL STOCK
RENEWAL PARTS CA2--- CD5--- CA4--- CD6---- CB2---- CB4---- ' PARTS RECOMMENDED FOR NORMAL STOCK NOTE: The current is identified by the number following the voltage letter in the IC designation. EXAMPLE:
More informationNEMA Full Voltage Power Devices. Section 1. Control Catalog 1-1
NEMA Rated Full Voltage Power Devices Application Information and Technical Data (300-Line)...-4 Magnetic Nonreversing Starters (CR306, CR386) Basic Features (300-Line) and Technical Features (CR306, CR386)...-7
More informationwww. ElectricalPartManuals. com GENERAL. ELECTRIC RENEWAL PARTS CR7006-C100, -C101 AND -C102 MAGNETIC STARTERS
RENEWAL PARTS CR7006-C100, -C101 AND -C102 MAGNETC STARTERS CR7006-C1 OOA, -C1 008, -C1 OOC, -C1 000, -C1 01 A, -C1 01 B, -C1 01 C, -C1 010, -C1 01 Q, -C1 02A, -C1 028, -C1 02C, -C1 020 and -C1 02Q GEF-3!5470
More informationFlorham Park, NJ USA Call (ASCO) for sales or service
Operator s Manual 7000 Series ATS Automatic Transfer Switches D design, 30 through 230 A DANGER is used in this manual to warn of a hazard situation which, if not avoided, will result in death or serious
More informationInstruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035
Instruction Bulletin 4402-997-0 February 999 Middletown, OH, USA DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 605 DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker
More informationA-Series II Panelboards AD/AE/AQ Type P & N Panel THQB Three-Phase Circuit Breaker Kits
g Introduction A-Series II Panelboards AD/AE/AQ Type P & N Panel THQB Three-Phase Circuit Breaker Kits These instructions describe the installation of THQB three-phase circuit breaker kit into an A-Series
More informationDEF-002. Vacuum Limitamp Medium Voltage Motor Control CR194
DEF-002 Vacuum Limitamp Medium Voltage Motor Control CR194 Table of Contents Introduction...1 Reference Publications...1 Parts Identification...,...1 High-Voltage Contactor Nameplate...1 Limitamp Panel
More information1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175.
SIRIUS 3RT0 3-Pole with AC Coil 3RT0* through 3RT04* 4-point AC coil can be wired on top, bottom, or diagonally. Direct mount 3RU or 3RB0 solid state overload relays to create starters. Snap-on auxiliary
More informationwww. ElectricalPartManuals. com GENERAL. ELECTRIC RENEWAL PARTS METAL-CLAD SWITCHGEAR TYPES M-26 AND M-36 GEF-4351C Supersedes GEF-4351B
Data subject to change without notice. RENEWAL PARTS METAL-CLAD SWTCHGEAR TYPES M-26 AND M-36 ORDERNG NSTRUCTONS 1. Always specify the complete nameplate data of the equipment. GEF-4351C Supersedes GEF-4351B
More information4.7. Definite Purpose Contactors and Starters. Contents. Reversing/Assignment Contactor. Direct Current Contactors
Direct Current Contactors.7 Contents Description Mill Type Contactors....................... 600V Contactors.......................... DPM 750V Contactor...................... AVD Contactor...........................
More informationMicroVersaTrip Plus and MicroVersaTrip PM Conversion Kits For GE Types AK-25 and AKU-25 Low Voltage Power Circuit Breakers
g DEH-126 Supplementary Instructions MicroVersaTrip Plus and MicroVersaTrip PM Conversion Kits For GE Types AK-25 and AKU-25 Low Voltage Power Circuit Breakers SUPPLEMENTARY INSTRUCTIONS ONLY This publication
More informationMetal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents
January 2003 Vol. 1, Ref. No. [1011] -1 Medium Voltage Metal-Enclosed Switches Contents Description Page MVS................................... -2 and Breaker MSB........................ -3 Metal-Enclosed
More informationSIEMENS. Series 8100oT Vacuum Controllers. www. ElectricalPartManuals. com. Bulletin CC
c c SIEMENS Series 8100oT Vacuum Controllers Bulletin CC3802-02 Technological Development Vacuum technology has developed rapidly in recent years and is becoming widely accepted for medium voltage motor
More informationGEF-4647A. GE Drive Systems. Renewal Parts. HEAVY DUTY DC CONTACTORS DS303Al (600V STYLE) DS303Bl (looov STYLE) www. ElectricalPartManuals.
GEF4647A GE Drive Systems Renewal Parts HEAVY DUTY DC CONTACTORS DS303Al (600V STYLE) DS303Bl (looov STYLE) DS303 A 1 A 01 A B c AF 11A TABLE 1 NAMEPLATE DENTFCATON OF CONTACT A 1 Normally open POLE CONFGURATON
More informationTest Cabinet (Inspection Box) Instructions. for Testing Accessories on Manually and Electrically Operated EntelliGuard G Low Voltage Circuit Breakers
DEH41480 Test Cabinet (Inspection Box) for Testing Accessories on Manually and Electrically Operated EntelliGuard G Low Voltage Circuit Breakers Instructions 1 Table of Contents Section 1. Introduction
More informationData Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931
Data Bulletin 0931DB0101 July 2001 Cedar Rapids, IA, USA Ground-Censor Ground-Fault Protection System Type GC Class 931 09313063 GT Sensor Shunt Trip of Circuit Interrupter Window Area for Conductors GC
More informationIllustrated Parts List for GPU-400
Illustrated Parts List for GPU-400 Series 500082-4xx 28.5 Volts, 400 Amps Section 1 Illustrated Parts List 1) Explanation of Parts List Arrangement The parts list is arranged so that the illustration will
More information600 D 220 E 230 J Hanover Road, Florham Park, New Jersey USA For sales or service call (ASCO)
Operator s Manual Series 386 Electrically Operated Non Automatic Switches J design 600 amps DANGER is used in this manual to warn of high voltages capable of causing shock, burns, or death. WARNINGisusedinthismanualtowarn
More informationMotor Control. Motor Control Electrical Aftermarket Products and Services Contents
June 00 Aftermarket Solutions, Ref. No. [] - CA0000E Contents Description Page Contactors, Starters & Brakes................................... - Product Description.........................................
More informationCrane Control. Crane Control 1. Contents. Description Heavy-Duty Brakes Shoe Brakes Magnetically Operated Master and Limit Switch Family
October 008 Contents Description Page HeavyDuty Brakes Shoe Brakes Magnetically Operated........................... Master and Limit Switches Type F Master Switches GH0............................... Type
More information5 Series - Mechanical Latch 2PDT - 4PST, 30 Amps
5 Series - Mechanical Latch 2PDT - 4PST, 30 Amps The 5 series is a 2 coil mechanical latch electrical reset power relay. It is panel mounted with screw terminals, and has 600 volt spacing. The 5 series
More informationMedium Voltage Equipment. Section 15.
MV One Line...15-2 Motor Control Medium Voltage (Limitamp ) Introduction, Features, Types, Options, References...15-3 Specifications, Ratings, Equipment Reference Publications...15-4 Product Scope...15-5
More informationC E R T I F I C A T E O F C O M P L I A N C E
Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that representative samples of Motor Controllers, Magnetic USL, CNL - Type No 3RT10, 3RT11,
More informationGE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc
GE Industrial Solutions User/Installation Manual for 4.76kV -15kV SecoBloc Index General Scope...3 Standards...3 Operating conditions...3 Technical specification...3 Basic structure Features...4 Operation...4
More informationCradle Mounted Key Interlock Guide Frame Accessory
s Cradle Mounted Key Interlock Guide Frame Accessory Cat. No.: WLDLKRK, WLDLSUP, WLDLDKRK, WLDLDSUP, WLDLPR, WLDLDPR For Use With: Circuit Breaker Adapters WLG _ 3 Installation Instructions Instruction
More informationcontactor may be required to interrupt up to 200% current. The N.O. contacts are equipped with permanent magnet blowouts to meet this requirement.
DP Contactors DC Control DP Definite Purpose Contactors are designed for DC adjustable speed drive circuits using silicon controlled rectifier switching and other controls where a combination of normally
More informationFrame Sizes: AKJ/ AKJT I AKJU-50 and AKR/ AKRU-30/ 50, AKRT-50
RENEWAL PARTS LOW VOLTAGE POWER CIRCUIT BREAKERS Frame Sizes: AKJ/ AKJT I AKJU-50 and AKR/ AKRU-30/ 50, AKRT-50 GEF-4527F Supersedes GEF-4527E TABLE A. INDEX OF BREAKER MODELS COVERED BY THIS PUBLICATION
More informationPoweMr' With 18 Mechanism '. 1 . / ,, ( c :11t
) rvac Vacuu m Circuit. Breaker PoweMr' With 8 Mechanism L- '.. /,, ( (' p c :t ) FRONT VIEW,. 0 3 Fig. Front View of Breaker with Front Cover 3. COUNTER 0. INTERRUPTER ASSEMBLY Fig. 2 Front View of Breaker
More informationUniversal Retrofit System Installation Instructions Revised:
Universal Retrofit System Installation Instructions Revised: 20150624 These instructions do not purport to cover all details or variations in components nor to provide for every possible contingency to
More informationSection 11. Specialty Control Devices. Control Catalog 11-1
Industrial Strongbox Solenoids (CR9500) Introduction...11-2 AC Solenoid Forms...11-3 Mounting Options and Accessories for AC Forms...11-3 DC Solenoid Forms...11-4 Outlines and Dimensions...11-4 Heavy Duty
More informationULTRA PERFORMANCE LED TUBE INSTALLATION INSTRUCTIONS
Ultra Performance LED Tube Installation Instructions Page 1 of 7 ULTRA PERFORMANCE LED TUBE INSTALLATION INSTRUCTIONS These instructions do not purport to cover all details or variations in components
More informationVacuum Contactors and Starters
Vacuum s and Starters Size 4 Vacuum.1 Product Description....................................... Application Description.................................... Operation...............................................
More informationDistribution Cable Harness For Spectra RMS Molded-Case Circuit Breakers with microentelliguard TM, MicroVersaTrip PM or MicroVersaTrip Plus Trip Units
GE Energy Industrial Solutions GEH-6255 Installation Instructions Distribution Cable Harness For Spectra RMS Molded-Case Circuit Breakers with microentelliguard TM, MicroVersaTrip PM or MicroVersaTrip
More informationMagnetic Overload Relays
Magnetic Overload Relays Series N147 Series N147 Overload Relays are of the magnetically operated self reset type, designed for use on or motor starters and controllers for Navy Service A applications.
More informationVacClad-W type VCP-W 5 and 15 kv, 36-inch-wide switchgear components
Supersedes July 2002 Contents Page Procedure for identifying parts... 2 Customer ordering instructions.... 2 Distributor ordering instructions.... 2 Front panel components.... 3 Breaker pan assembly....
More informationSIGNAL WORDS QUALIFIED PERSON
SIGNAL WORDS The signal words Danger, Warning and Caution used in this manual indicate the degree of hazard that may be encountered by the user. These words are defined as: Danger - Indicates death or
More informationMedium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION
Medium Voltage Standby non-paralleling Control 1. GENERAL GUIDE FORM SPECIFICATION A. The requirements of the contract, Division 1, and part 16 apply to work in this section. 1.01 SECTIONS INCLUDE A. Medium
More informationGE CONSUMER & INDUSTRIAL
GE CONSUMER & INDUSTRIAL GE POWER/VAC MANUAL GROUND AND TEST DEVICE Types PVV-1200/2000-10 PVV-3000-10 PVV-1200-20 PVV-2000-20 PVV-1200/2000-20 PVV-3000-20 PVV-1200/2000/3000-20 Instruction Number GEK-86125B
More informationAC Relays. Type IC5182. Ordering Information. Control Power Requirements. Contact Ratings (Amperes)
AC Relays Type IC5182 Series N147 Overload Relays are of the magnetically operated self reset type, designed for use on A.C. or D.C. motor starters and controllers for Navy Service A applications. Specification
More informationwww. ElectricalPartManuals. com Type AM ,-6 Magne-Biast Circuit Breakers RENEWAL PARTS GENERAL. ELECTRIC GEF-4438A Supersedes GEF-4438
Ordering Instructions RENEWAL PARTS 1. Always specify the complete nameplate data of the relay, including complete model of relay. 2. Specify the quantity, catalog number (if listed), reference number
More informationInstallation Instructions For Motor Control Center (MCC) Units
s Page 1 of 8 Installation Instructions December, 2013 Installation Instructions For Motor Control Center (MCC) Units Hazardous voltage. Will cause death or serious injury. Always de-energize and ground
More informationLBI-30246F INSTRUCTIONS FOR FUSE PANELS 19C327027G1, G2, G4, G5, G8, G9, G10, G11, G14 & G15 AND FILTER PANEL 19D423732G1 DESCRIPTION
LBI-30246F INSTRUCTIONS FOR S 19C327027G1, G2, G4, G5, G8, G9, G10, G11, G14 & G15 AND FILTER PANEL 19D423732G1 TABLE OF CONTENTS Page DESCRIPTION.............................................. Front Cover
More informationBussmann series Quik-Spec Power Module Switch elevator disconnect
Supersedes January 2016 Agency information UL 98 enclosed and dead-front switch - Guide WIAX, WIAX7 (Canada), File E182262 culus, NEMA 1, UL 50, Listed enclosure cul per Canadian Standards C22.2, No. 0-M91-CAN/
More informationProgrammable Logic Controller. Mat Nor Mohamad
Programmable Logic Controller Mat Nor Mohamad Relays Electromagnetic Control Relays The PLC's original purpose was the replacement of electromagnetic relays with a solid-state switching system that could
More informationCerti cation Record INDUSTRIAL CONTROL EQUIPMENT Motor Controllers Magnetic
Certi cation Record Customer Schneider Electric USA, Inc. Square D Raleigh (Knightdale) Plant, 8001 Knightdale Blvd Knightdale NC USA 27545 Class 3211 04 INDUSTRIAL CONTROL EQUIPMENT Motor Controllers
More informationINSTRUCTIONS HAA 15A / 15B / 15C / 15D / 15E / 15F / 15G / 15H AUXILIARY CURRENT RELAYS
g INSTRUCTIONS HAA 15A / 15B / 15C / 15D / 15E / 15F / 15G / 15H AUXILIARY CURRENT RELAYS Manual Part Number: GEI-83964H Copyright 2000 215 Anderson Avenue Markham, Ontario L6E 1B3 Canada Telephone: (905)
More informationSECTION PANELBOARDS
SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under
More informationA200 NEMA Contactors and Starters A200
Starters Non-reversing and Reversing 11 Not to be used for construction purposes unless approved. Table 11. Open Reversing Starters Dimensions NEM of Poles Fig. Mounting Dimensions in Inches (mm) Screws
More informationA-Series II Panelboards AD/AE/AQ Type P & N Power Panel SE/TED Three-Phase Circuit Breaker Kits
g Introduction A-Series II Panelboards AD/AE/AQ Type P & N Power Panel SE/TED Three-Phase Circuit Breaker Kits These instructions describe the installation of SE/TED three-phase circuit breaker kit into
More informationFlorham Park, NJ USA Call (ASCO) for sales or service
Operator s Manual 4000 Series ATS Automatic Open-Transition Transfer Switches D design 30 230A, J design 260 600A, H-design 800 1200A, G-design 1600 4000A, F-design 4000A DANGER is used in this manual
More informationDEH Installation
g A-Series II Panelboards AD/AE/AQ Type P & N Power Panel SG Three-Phase Circuit Breaker Kits Introduction These instructions describe the installation of SG three-phase circuit breaker kit into an A-Series
More informationHeavy Duty DC Contactors for Power Distribution Centres
for Power Distribution Centres SW260, SW500, SW560, SW600, SW800, SW1000 & SW1500 TYPES SW260A SW800A SW1500A DC Contactors for Power Distribution Centres The Range SW260(A) SW500(A) SW560(A) SW600(A)
More informationCerti 堵脝 cation Record
Certi 堵脝 cation Record Customer Schneider Electric USA, Inc. Square D Raleigh (Knightdale) Plant, 8001 Knightdale Blvd Knightdale NC USA 27545 Class 214 INDUSTRIAL CONTROL EQUIPMENTMotor Controllers Magnetic
More informationMedium Voltage Metal-Enclosed Switches
Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Medium Voltage Switch MVS Product Description............................................. 2 Application Description..........................................
More informationC E R T I F I C A T E O F C O M P L I A N C E
Issued to: SIEMENS AG DF CP R&D V 3 WERNER-VON-SIEMENS-STRASSE 48 92224 AMBERG, GERMANY This is to certify that representative samples of Combination Motor Controllers (See following pages for additional
More information2.54mm Pitch Card Edge Connector
2.54mm Pitch Card Edge Connector CR22 Series Product Standards Rating Current rating: 3A Voltage rating: 0VAC Operating Temperature Range: - to +85ç (Note 1) Operating Humidity Range: 40 to % Storage Temperature
More informationStrip Fixture URS Light Bar Retrofit Installation Instructions Revised:
Strip Fixture URS Light Bar Retrofit Installation Instructions Revised: 20180126 These instructions do not purport to cover all details or variations in components nor to provide for every possible contingency
More informationwww. ElectricalPartManuals. com POWER CIRCUIT BREAKERS TYPES AK-2/3/2A/3A-50, AKU-2/3/2A/3A-50, AKT-2/3/2A/3A-50 GENERAL fj ELECTRIC
ORDERNG NSTRUCTONS. Always specify complete nameplate data of the breaker. 2. Specify the quantity, catalog number (if listed), reference number (if listed), description, and this bulletin number. 3. Standard
More informationEntelliGuard Power Circuit Breaker Accessories. Network Interlock for Ampere Circuit Breakers. Introduction. Operation
DEH41118 Installation Instructions R01 R02 g EntelliGuard Power Circuit Breaker Accessories Network Interlock for 3200-5000 Ampere Circuit Breakers Introduction The Network Interlock provides a means of
More informationINSTRUCTIONS FOR REMOVAL OF GROUND FAULT PROTECTION DEVICE FROM HOBART GENERATOR SETS SPECIFICATION NUMBERS
081385 INSTRUCTIONS FOR REMOVAL OF GROUND FAULT PROTECTION DEVICE FROM HOBART GENERATOR SETS SPECIFICATION NUMBERS 6184-2 HOBART BROTHERS COMPANY Power Systems Division Troy, Ohio 45373 INSTRUCTIONS FOR
More informationDISCONNECT SWITCHES (16 TO 630 amp)
I DISCONNECT SWITCHES (16 TO 630 amp) Springer Controls is partnered with MERZ-PCE, a world leader in the manufacturing of switch gears. We carry a complete line of UL approved, CSA listed, Disconnect
More informationSecoVac * Ground & Test Device
GE Industrial Solutions DEH-50007 Installation, Operation and Maintenance Manual SecoVac * Ground & Test Device For 5kV-15kV IEEE Metal-clad Switchgear Table of Contents 1. Introduction...6 Safety Precautions...6
More informationStarters. Across the line. Across the line starters Open & enclosed A9 AF750. Description A9 AF750. Starters. Enclosure types
Across the line starters & enclosed A9 AF750 Across the line Description A9 AF750 Maximum UL horsepower ratings UL508A Panel Program, #E105450 NEMA s (00 7) available Compact space-saving design Standard
More informationGenerator Fire Safety: Generator assemblies should be located outside the building.
SECTION 33 70 00 - ELECTRICAL DISTRIBUTION PACKAGED GENERATOR ASSEMBLIES Generator Fire Safety: Generator assemblies should be located outside the building. All fuel piping from the outside of the building
More information50 Hanover Road, Florham Park, New Jersey USA For sales or service call (ASCO)
Operator s Manual 7000 Series ATS Automatic Transfer Switches H design 600 through 1200 amps TABLE OF CONTENTS section-page INSTALLATION... 1-1 Mounting and Line Connections... 1-1 Auxiliary Circuits and
More informationDescription. Positive safety relays
Type N & KC Positive safety Description A.C. or D.C. operated DIN rail or panel mounting 600 volt heavy duty design, A600-10 amp, Q300-5 amp Snap-on accessories available: 1 & 4 pole adder deck Pneumatic
More informationNEMA Vacuum Break Contactors and Starters
NEMA Vacuum Break Contactors and Starters NEMA Vacuum Break Starter.1 Product Description....................................... Application Description.................................... Operation...............................................
More informationTable of Contents. HCC Contactor Nomenclature
Table of Contents HC HCC SERIES: Definite Purpose Contactors... Page 1 Auxiliary Switches & Termination Drawings HCC SERIES: 1 & Pole Definite Purpose Contactors... Page 0 HCC SERIES: & Pole Definite Purpose
More informationGEF~4630A. Limitamp Medium-Voltage Motor Control. CR7160 Renewal Parts Bulletin
GEF~4630A Limitamp Medium-Voltage Motor Control CR7160 Renewal Parts Bulletin ',; @ Limitamp" Medium VoUage Matar Control Table of Contents Introduction...2 Parts Identification...2 High-Voltage Contactor
More informationInverse-Time Overcurrent & E/F Relays. Type ICM 21, ICM 21B. Station Automation & Protection. ABB Substation Automation Products
Station Automation & Protection Inverse-Time Overcurrent & /F Relays Type ICM, ICM B ABB Substation Automation Products Features the driving solenoid has tappings, corresponding to the seven stages of
More informationSM-1700 Secondary Shunt Trip Coil Assembly. Powered by Safety
SM-1700 Secondary Shunt Trip Coil Assembly Powered by Safety SM-1700 Secondary Shunt Trip Coil Assembly SM-1700 Contact Information Powell Electrical Systems, Inc. www.powellind.com info@powellind.com
More informationABB Automation, Inc. Substation Automation & Protection Division Coral Springs, FL Allentown, PA
ABB Automation, Inc. Substation Automation & Protection Division Coral Springs, FL Allentown, PA Instruction Leaflet I.L. 41-661.1B Effective: June 1997 Supersedes I.L. 41-661.1A, Dated February 1994 Type
More informationLow-Peak 600V Class RK1
LPS-RK 600Vac/300Vdc, 1 10-60A, Dual Element, Time-Delay Fuses Dimensions - in 5" (± 0.31) 5.5" (± 0.31) Available with easyid open fuse indication 1/10 to 30A 0.81" (±0.008) 35 to 60A 1.06" (±0.008) Description:
More informationCutler-Hammer. AMPGARD MV Motor Control Vacuum Break SJ Series II II. Renewal Parts. r II li I. Pages. Contents. Effective: March 2000 Page 1
! ' ICc@l Cutler-Hammer New Information Supersedes RPD8855V (August 1994) Renewal Parts Effective: March 2000 Page 1 AMPGARD MV Motor Control Vacuum Break SJ Series Contents Pages 400 Amp Starters ADM
More information1800/1000 Frame RC Snubber Board IS200RCSAG1A
GEI-100303 g GE Industrial Systems 1800/1000 Frame RC Snubber Board IS200RCSAG1A Safety Symbol Legend Indicates a procedure or condition that, if not strictly observed, could result in personal injury
More informationOperator s Manual Series ADTS Automatic Delayed Transition Transfer Switches 150 through 4000 amp. Rating Label. Nameplate A
Operator s Manual 7000 Series ADTS Automatic Delayed Transition Switches 150 through 4000 amp. Note: Refer to the outline and wiring drawings provided with your 7000 Series ADTS for all installation and
More informationType SOQ Negative Sequence Time Overcurrent Relay
ABB Power T&D Company Inc. Power Automation & Protection Division Coral Springs, FL Allentown, PA April 1998 Supersedes DB dated August 1991 Mailed to: E,D, C/41-100B For Protection of Rotating Machinery
More informationContactor V-Contact VSC/P
Argentina Buenos Aires November 30, 2006 Contactor V-Contact VSC/P 1VCP000XXX Rev.B, en Presentation - 2006.XX. V-Contact VSC Contactors QUALITY SYSTEM : Certification ISO 9001-2000 ENVIRONMENTAL MANAGEMENT
More informationContactors. Contactors ensure positive safety between their auxiliary contact blocks. Easy coil change Captive terminal screws
A9 - AF1650 11 Contactors A9 - A110 Maximum UL/CSA horsepower ratings according to UL508 and CSA22.2 No. 14 Includes NEMA sizes 00-3 CE mark Compact space saving design Standard auxiliary contact configurations:
More information