1 -- GEF-6005 Renewal Pans low Vohage Power Circuit Breakers Type AKR-30S and AKRU-30S
2 INTRODUCTION This manual provides a listing of the parts and assemblies that are availle as replacement parts for low voltage circuit breakers, types AKR-30S and AKRU-30S. Parts and assemblies included in this list are from the basic breaker. To order parts and assemblies for breaker accessories, refer to summary list or the breaker nameplate data. When ordering renewal parts, specify catalog number and the quantity required. Complete nameplate data of breaker involved should be given, as well as an accurate description and part number of each part required. Direct your order to your local GE ED & C sales office. Renewal parts which are furnished may not be identical to the original parts since, from time to time, design changes may be made. The parts supplied, however, will be interchangele with the original parts. INDEX OF RENEWAL PARTS COVERED BY THIS PUBUCATION Quantity Required Fig. For 3-Pole Breaker Catalog No. AKR-30S AKRU-30S Number Description l A8843Pl Connector 2 I l ** MicroVersaTrip RMS 9 Programmer 3 I l ** Epic MicroVersaTrip Programmer 4 - I 108C9667G2 Open Fuse Lock out (OFLO Device) 5 l l 567B686G8 MicroVersaTrip flux Shifter See Tle A Current Transformer C257G l5 Movle Contact Arm Assembly B582Gl Upper Stud Assembly A8858Gl, G2, G3 Stationary Contacts (Requires all A6990P387 Spring B288G2 Arc Chute groups per phase) 10 I 3 184L 700BFG22 Back Frame (complete) II I I See Tle B Undervoltage Device 12 l l See Tle C Relays 13 3 * 3 * 386A l log2 Secondary Disconnect Terminal Block 14 1 I See TleD SB.J2 Auxiliary Switch 15 I 1 See Tle E Electroswitch Auxiliary Switch l92a9668g 15 Primary Disconnect 17 l I Sec Tle F Shunt Trip 18 1 I 269C277G1 Crossbar A8711Gl Lower Stud 20 I 1 622C505G l Cut off Switch Assembly 21 I I See Tle G Closing Solenoid Coil 22 I I ti22c529g I Closing Push Button 23 I I 184L700FMG23 Front Frame (Electric) 24 I I 184L700FMG22 Front Frame (Manual) 25 I I 184L700DOG37 Draw out, Racking and Interlocks only * Maximum quantity ** Refer to side sticker on programmer unit for replacement information. ORDERING INSTRUCTIONS 1. Furnish the complete nameplate data of the breaker. (Drawing reference 425D445Pl) 2. Specify quantity, cat. no., item no. and description for each part, and state this bulletin no. 3. Standard hardware items (zinc dichromate-coated screws, grade 5 bolts, nuts, washers, etc.) are not listed in this bulletin. These items, or equivalent, should be obtained locally For pricing, contact your local GE ED & C sales office.
3 r. t :O :\ ;,\ '<,''_,;, "'"*",_ () J Figure 1. Connector Figure 2. Micro VersaTrip RMS-9 P rogrammer Figure 3. Epic Micro VersaTrip Programmer Figure 4. Open Fuse Lock-out Figure 5. MicroVersaTrip Flux Shifter Amp Range HOO Figure 6. Current Transformer -Ctbk \.Cut tent Tr,tnsfmmcrs,llld ICttin.; Plugs Current Transformer 139C4970G C4970G218 (' 'H'' Option) 139C4970G C4970G221 ("H" Option) I K:4970G211 Rating Plug TR1S60 TR1S80 TR1S100 TR1S125 TR1S150 TR4S150 TR4S200 TR4S225 TR4S250 TR4S300 TR4S400 TR8S300 TR8S400 TR8S500 I : 9C4970G223 TR8S600 TR8S700 I I
4 4 Figure 8. Upper Stud Assembly Figure 7. Figure 10. Back Frame (Complete) Movle Contact Arm Assembly Figure 9. Arc Chute Volts Figure 11. Undervoltage Device Hertz Tle B. l:ndervoltagc Device Instantaneous Undervoltage Device Complete with Coil Time Delay Undervoltage Device Complete with Coil (Less Mounting) Coil Only (Less Mounting) Coil Only Cat. Cat. Cat. Cat. 568B309- K B309- K DC G1 G15 4ll oc DC 3 18 c; :1 G DC {) {) 'JO ''W'' or ''E'' Relay Figure 12. Relays " Tle C. Rcla s Voltage 48VOC 125V DC 250V DC 120V mhz 120V 50HZ 203V 60HZ 208V 50HZ 240V 60HZ 240V 50HZ "K" or "X" Relay 192A9770 PI 192A9770 P2 192A9770 P3 192A9770 P4 192A9770 P5 192A9770 P6 192A9770 P7 192A9770 PS 192A9770 P9 "K" or "X" Relay 59 "W" or "E" Relay 192A9771 PI 192A9771 P2 192A9771 P3 192A9771 P4 192A9771 P4 192A9771 P5 192A9771 PS 192A9771 P6 192A9771 P6
5 Figure 13. Secondary Disconnect Terminal Block Cat. No. 192A9791Pp Figure 14. SB-12 Auxiliary Switch Tle D. SB-12 Auxiliary Switch Stages 2 2 Figure 15. Electroswitch Auxiliary Switch Cat. No. 242R7016P17 242B7016P20 Stages Contact aa Contact bb bb bb Volts Figure 17. Shunt Trip Hertz Figure 16. Primary Disconnect Tle E Shunt Trip Device Complete with Coil (Less Mounting) Cat. Coil Only Cat. 139C K oc G1 G55 4B oc oc oc BO BO Figure 18. Crossbar 5
6 6 Figure 20. Cut-off Switch Assembly Figure 21. Closing Solenoid Coil Voltage 43VOC 125V OC 250V OC 120V 60HZ 120V 50HZ 208V 60HZ 208V 50HZ 240V 60HZ 240V 50HZ Tle G. Closing Solenoid Coil Figure 22. Closing Push Button Figure 19. Lower Stud Closing Solenoid Coil 366A773G17 366A773G13 366A773G A773G1 366A773G2 366A773G3 366A773G3 366A773G4 366A773G5 Figure 23. Front Frame (Electric) Figure 24. Front Frame (Manual) Figure 25. Draw-out (Racking and Interlocks Only)
7 7
8 General Electric Company 4! Woodford Ave., Plainville, CT GEF BLE 1989 General Electric Company GE Electrical Distribution & Control
www. ElectricalPartManuals. com
SPEC-SETTER Type TH HEAVY DUTY SAFETY ES LOAD BLOCK CATALOG MODEL NUMBER NO. BLOCK THJ 343L68G97 TH M 343L68G97 THMK 343L68G97 THMSS 343L68G97 THSS 343L68G97 THJ 343L68G0 THM 343L68G0 THMK 343L68G0 THMSS
More informationDEF 005. WavePro Power Circuit Breakers A Frames, Vac. Renewal Parts
g DEF 005 WavePro Power Circuit Breakers 3200 5000 A Frames, 240 600 Vac Introduction This guide contains a listing of the parts and assemblies that are available as replacement parts for WavePro 3200
More informationFrame Sizes: AKJ/ AKJT I AKJU-50 and AKR/ AKRU-30/ 50, AKRT-50
RENEWAL PARTS LOW VOLTAGE POWER CIRCUIT BREAKERS Frame Sizes: AKJ/ AKJT I AKJU-50 and AKR/ AKRU-30/ 50, AKRT-50 GEF-4527F Supersedes GEF-4527E TABLE A. INDEX OF BREAKER MODELS COVERED BY THIS PUBLICATION
More informationRENEWAL PARTS AK-2-15 AK-2-25 AK-3-25 AKF-2-25 AK-2A-15 AK-2A-25 AK-3A-25 AKF-2A-25 AKU-2-25 AKU-3-25 AKU-2A-25 AKU-3A-25
Data ubject to change without notice. RENEWAL PARTS POWER CIRCUIT BREAKERS TYPES 225 AMP FRAME SIZE 00 AMP FRAME SIZE GEF-449G Supersedes GEF-449F AK-2-5 AK-2-25 AK-3-25 AKF-2-25 AK-2A-5 AK-2A-25 AK-3A-25
More informationBBC. Renewal Parts. I-T-E Low-Voltage Power Circuit Breakers
BBC BROWN BOVERI RP 6..2.8-2C Renewal Parts I-T-E Low-Voltage Power Circuit Breakers Type K-000, 4000, 0008, and 40008 Stationary and Drawout Mounted 000 and 4000 Amperes 600 Volts RP 6..2.8-2 Page 2 Table
More informationCD5--- CA4--- CD6---- CB2---- CB4---- PARTS RECOMMENDED FOR NORMAL STOCK
RENEWAL PARTS CA2--- CD5--- CA4--- CD6---- CB2---- CB4---- ' PARTS RECOMMENDED FOR NORMAL STOCK NOTE: The current is identified by the number following the voltage letter in the IC designation. EXAMPLE:
More informationPage 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut
Page 1 Supersedes Renewal Parts Data 33-790-1G pages 1-20 dated December, 1988 Mailed to: C, D, E/33-700 Westinghouse DS and DSL Low Voltage Power Circuit Breakers and Cell Parts Contents Pages DS Breaker
More informationwww. ElectricalPartManuals. com POWER CIRCUIT BREAKERS TYPES AK-2/3/2A/3A-50, AKU-2/3/2A/3A-50, AKT-2/3/2A/3A-50 GENERAL fj ELECTRIC
ORDERNG NSTRUCTONS. Always specify complete nameplate data of the breaker. 2. Specify the quantity, catalog number (if listed), reference number (if listed), description, and this bulletin number. 3. Standard
More informationCR193 B,C,D and E Vacuum Limitamp * Contactors
GE Industrial Solutions CR19 B,C,D and E Vacuum Limitamp * Contactors Renewal Parts Bulletin Table of Contents General Information... Contactor Matrix... 4 Mounting Plates, Pull Handle, Interlock Driver
More informationRENEWAL PARTS I C302AA A-2 300V AB A-4800V A C A -SOOOV PARTS RECOMMENDED FOR NORMAL STOCK
NGrE: RENEWAL PARTS IC0A HIGH VOLTAGE CONTACTORS I C0AA 00A 00V AB00A800V A C 00A SOOOV PARTS RECOMMENDED FOR NORMAL STOCK The current is identified by the number following the voltage letter in the IC
More informationInstruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035
Instruction Bulletin 4402-997-0 February 999 Middletown, OH, USA DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 605 DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker
More informationwww. ElectricalPartManuals. com Type AM Magne-Biast Circuit Breakers RENEWAL PARTS
RENEWAL PARTS Ordering Instructions 1. Always specify the complete nameplate data of the breaker. 2. Specify the quantity, catalog number (if listed), reference number (if listed) description, and this
More informationProTrip Conversion Kits. For GE Types AK-15, AK-25, and AKU- 25 Low-Voltage Power Circuit Breakers INTRODUCTION. DEH Installation Instructions
DEH 40026 Installation Instructions g ProTrip Conversion Kits For GE Types AK-15, AK-25, and AKU- 25 Low-Voltage Power Circuit Breakers INTRODUCTION GE Conversion Kits are designed for upgrading existing
More informationwww. ElectricalPartManuals. com BBC Brown Boveri Electric Renewal Parts 1-T -E Low-Voltage Power Circuit Breakers
i BBC BROWN BOVERI Type LK and LKE 800 thru 4200 Amperes Type LKD 800 and 1600 Amperes 600 Volts RP 6118A Renewal Parts 1-T -E Low-Voltage Power Circuit Breakers Brown Boveri Electric RP 6118-1A Page 2
More informationPower Break II Switchboard
Power Break II Switchboard Now available with PowerBreak II Circuit Breakers through 4000A GE s Power Break II Switchboard is now available with the new Power Break II Insulated Case Circuit Breaker (800A
More informationMicroVersaTrip Plus and MicroVersaTrip PM Conversion Kits For GE Types AK-25 and AKU-25 Low Voltage Power Circuit Breakers
g DEH-126 Supplementary Instructions MicroVersaTrip Plus and MicroVersaTrip PM Conversion Kits For GE Types AK-25 and AKU-25 Low Voltage Power Circuit Breakers SUPPLEMENTARY INSTRUCTIONS ONLY This publication
More informationB CW POWER RELAY
41-241.31B CW POWER RELAY nected in such a way that current, (I A ), leads voltage, (V BA ), by 150 degrees when the motor is operating at unity power factor. Loss of excitation to the motor causes a large
More informationInstructions for A200, A210, A250 size 6, two- or three-pole non-reversing or reversing motor controllers
Instruction Leaflet IL0330300E Supersedes I.L. 7055C, Pages 8, Dated June 998 Instructions for A00, A0, A50 size 6, two- or three-pole non-reversing or reversing motor controllers Contents Description
More informationBussmann series Quik-Spec Power Module Switch elevator disconnect
Supersedes January 2016 Agency information UL 98 enclosed and dead-front switch - Guide WIAX, WIAX7 (Canada), File E182262 culus, NEMA 1, UL 50, Listed enclosure cul per Canadian Standards C22.2, No. 0-M91-CAN/
More informationMagnetic Overload Relays
Magnetic Overload Relays Series N147 Series N147 Overload Relays are of the magnetically operated self reset type, designed for use on or motor starters and controllers for Navy Service A applications.
More informationOperation and Maintenance Manual
DEH-41482 GE Energy Industrial Solutions Low Voltage Switchgear Remote Racking Operator For AKR Circuit Breakers Cat. # AKREGRR 115 VAC, 60/50 Hertz Operation and Maintenance Manual TABLE OF CONTENTS Section
More information2.0 CONSTRUCTION AND OPERATION 3.0 CHARACTERISTICS K. CO (HI-LO) Overcurrent Relay
41-100K 2.0 CONSTRUCTION AND OPERATION The type CO relays consist of an overcurrent unit (CO), either an Indicating Switch (ICS) or an ac Auxiliary Switch (ACS) and an Indicating Instantaneous Trip unit
More informationwww. ElectricalPartManuals. com Type AM ,-6 Magne-Biast Circuit Breakers RENEWAL PARTS GENERAL. ELECTRIC GEF-4438A Supersedes GEF-4438
Ordering Instructions RENEWAL PARTS 1. Always specify the complete nameplate data of the relay, including complete model of relay. 2. Specify the quantity, catalog number (if listed), reference number
More informationwww. ElectricalPartManuals. com GENERAL. ELECTRIC RENEWAL PARTS METAL-CLAD SWITCHGEAR TYPES M-26 AND M-36 GEF-4351C Supersedes GEF-4351B
Data subject to change without notice. RENEWAL PARTS METAL-CLAD SWTCHGEAR TYPES M-26 AND M-36 ORDERNG NSTRUCTONS 1. Always specify the complete nameplate data of the equipment. GEF-4351C Supersedes GEF-4351B
More informationSECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.
SECTION 16904 MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS PART 2 PRODUCTS 01 MANUFACTURERS A. B. C. Eaton * * The listing of specific manufacturers above does not imply acceptance of their products
More informationLow Voltage Power Circuit Breakers
A-TYPE DRAWOUT Electrically Operated I GE/-861508 Installation Instructions Low Voltage Power Circuit Breakers Types AKR-30/50 and A -50 0-TYPE ORA WOUT \ Manually Operated B-TYPE DRAWOUT Electrically
More informationwww. ElectricalPartManuals. com Cutler-Hammer Power Breaker Center Renewal Parts for Low Voltage Power Circuit Breakers Types DB, DBL and DBF
New Information Control Relay Auxiliary Switch Operating Mechanism CutlerHammer Power Center 10 Maxwell Avenue Greenwood, SC 29646 1877276979 Closing Solenoid 2254 Renewal Parts for Low Voltage Power Circuit
More informationGE Electrical Distribution. Gerapid High Speed DC Circuit Breakers. On the move. imagination at work
GE Electrical Distribution Gerapid High Speed DC Circuit Breakers On the move imagination at work Gerapid High Speed DC Circuit Breakers To stay up and running today, you need equipment that delivers both
More informationFigure 1. Type CWP-1 Ground Relay (Front View) Figure 2. Type CWP-1 Ground Relay (Rear View) E
Figure 1. Type CWP-1 Ground Relay (Front View) Figure 2. Type CWP-1 Ground Relay (Rear View) 41-242.5E 2 Typical 60 Hertz time product curves for the type CWP-1 relay are shown in Figure 4 with 100 volts
More informationPoweMr' With 18 Mechanism '. 1 . / ,, ( c :11t
) rvac Vacuu m Circuit. Breaker PoweMr' With 8 Mechanism L- '.. /,, ( (' p c :t ) FRONT VIEW,. 0 3 Fig. Front View of Breaker with Front Cover 3. COUNTER 0. INTERRUPTER ASSEMBLY Fig. 2 Front View of Breaker
More informationBolted contact switches. Pringle switches
Bolted contact switches Pringle switches Eaton s Pringle bolted contact switches History Eaton s PringleT switches have helped pioneer the development of high-quality electrical products for commercial
More informationMedium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION
Medium Voltage Standby non-paralleling Control 1. GENERAL GUIDE FORM SPECIFICATION A. The requirements of the contract, Division 1, and part 16 apply to work in this section. 1.01 SECTIONS INCLUDE A. Medium
More informationEvolution * Series E9000 Motor Control Center
GE Industrial Solutions Evolution * Series E9000 Motor Control Center Renewal Parts Bulletin Table of Contents Introduction The E9000-Line motor control center, a quality product of the General Electric
More informationSelection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker
Selection and Application Guide Supplement WL UL1066 4-Pole Circuit Breakers usa.siemens.com/wlbreaker WL Power Circuit Breaker Table of Contents Ratings for UL 1066 (ANSI C37) Circuit Breakers Frame size
More informationGEF-4647A. GE Drive Systems. Renewal Parts. HEAVY DUTY DC CONTACTORS DS303Al (600V STYLE) DS303Bl (looov STYLE) www. ElectricalPartManuals.
GEF4647A GE Drive Systems Renewal Parts HEAVY DUTY DC CONTACTORS DS303Al (600V STYLE) DS303Bl (looov STYLE) DS303 A 1 A 01 A B c AF 11A TABLE 1 NAMEPLATE DENTFCATON OF CONTACT A 1 Normally open POLE CONFGURATON
More informationwww. ElectricalPartManuals. com GENERAL. ELECTRIC RENEWAL PARTS CR7006-C100, -C101 AND -C102 MAGNETIC STARTERS
RENEWAL PARTS CR7006-C100, -C101 AND -C102 MAGNETC STARTERS CR7006-C1 OOA, -C1 008, -C1 OOC, -C1 000, -C1 01 A, -C1 01 B, -C1 01 C, -C1 010, -C1 01 Q, -C1 02A, -C1 028, -C1 02C, -C1 020 and -C1 02Q GEF-3!5470
More informationA - Add New Information C - Change Existing Information D - Delete Information. Page 7. Delete the fourth paragraph beginning CAUTION
ABB Effective: November 1990 This Addendum Supersedes all Previous Addenda Addendum to Instruction Leaflet 41-137.3H Type KRD-4 Directional Overcurrent Ground Relay A - Add New Information C - Change Existing
More informationVOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS
VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS A. 11 KV SWITCHGEAR 1.0 SWITCHGEAR ASSEMBLY 1.1 Make : 1.2 Type : 1.3 Reference Standard : 1.4 Voltage (Nom./Max.) KV : 1.5 Phase, Frequency No,Hz.
More informationVacClad-W type VCP-W 5 and 15 kv, 36-inch-wide switchgear components
Supersedes July 2002 Contents Page Procedure for identifying parts... 2 Customer ordering instructions.... 2 Distributor ordering instructions.... 2 Front panel components.... 3 Breaker pan assembly....
More information[V] Common Control Transformer Control (See page 1-78 Note)
Bulletin NEM Combination Non-Reversing Starters Product Selection Circuit Breaker Type NEM Size Continuous mpere Rating [] Bulletin NEM starter sizes Overload relays: Eutectic supplied as standard, solid-state
More informationDistribution Cable Harness For Spectra RMS Molded-Case Circuit Breakers with microentelliguard TM, MicroVersaTrip PM or MicroVersaTrip Plus Trip Units
GE Energy Industrial Solutions GEH-6255 Installation Instructions Distribution Cable Harness For Spectra RMS Molded-Case Circuit Breakers with microentelliguard TM, MicroVersaTrip PM or MicroVersaTrip
More informationwww. ElectricalPartManuals. com Section 6 Low Voltage Power and DC Circuit Breakers
Introduction...6-1 EntelliGuard G Low Voltage Power Circuit Breakers...6-2 WavePro Circuit Breakers with Power+, Enhanced MicroVersaTrip Plus and MicroVersaTrip PM Trip Unit Systems...6-3 WavePro Low Voltage
More informationParts Manual. Transfer Switch. OTPCB (Spec A) 150/225/260 Amps. English Original Instructions (Issue 4)
Parts Manual Transfer Switch 50/225/260 Amps OTPCB (Spec A) English Original Instructions -203 962 0228 (Issue ) This catalog covers models produced under the Cummins /Onan and Cummins Power Generation
More informationInverse-Time Overcurrent & E/F Relays. Type ICM 21, ICM 21B. Station Automation & Protection. ABB Substation Automation Products
Station Automation & Protection Inverse-Time Overcurrent & /F Relays Type ICM, ICM B ABB Substation Automation Products Features the driving solenoid has tappings, corresponding to the seven stages of
More information3.0 CHARACTERISTICS E Type CO-4 Step-Time Overcurrent Relay
41-106E Type CO-4 Step-Time Overcurrent Relay A core screw accessible from the top of the switch provides the adjustable pickup range. The IIT contacts are connected in the trip circuit to trip instantaneously.
More informationData Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931
Data Bulletin 0931DB0101 July 2001 Cedar Rapids, IA, USA Ground-Censor Ground-Fault Protection System Type GC Class 931 09313063 GT Sensor Shunt Trip of Circuit Interrupter Window Area for Conductors GC
More informationTransfer switch GTEC open or delayed transition
Transfer switch GTEC open or delayed transition 40-1250 Amp Description The GTEC automatic transfer switch combines reliability and flexibility in a small, economical package for transferring loads between
More informationParts Manual. Transfer Switch. OTPCC (Spec A) 300/400/600 Amps. English Original Instructions (Issue 4)
Parts Manual Transfer Switch 00/00/600 Amps OTPCC (Spec A) English Original Instructions -20 962 0229 (Issue ) This catalog covers models produced under the Cummins /Onan and Cummins Power Generation brand
More informationCM52 Network protector
Network protector parts catalog CA024007EN New issue CM52 Network protector parts catalog Table of contents Breaker....3 Relay module....6 Tank...9 Accessories....13 2 www.eaton.com/cooperpowerseries Network
More informationFOR PRICES ON DSII and DSLII BREAKERS, REFER TO PRICE LIST PL.22B.01.P.E
Supersedes PL.44B.04.P.E Dated September 1998 600 Volts AC Maximum 200 ka, RMS Sym. Short Circuit Maximum 800-5000 Amps Continuous Effective: October 1999 Page 1 Index Page Table Description/Application...
More informationA. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified.
SECTION 26 24 13 LOW VOLTAGE SWITCHBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General
More informationMCCB Accessories to suit AF
MCCB s MCCB Accessories to suit 125-630AF Accessory fitting combinations INTERNAL General purpose types Micro-switch types Auxiliary Heavy duty types Bridge -contact types Auxiliary Shunt UVT Internal
More informationABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet
ABB Instruction Leaflet 41-137.2E Effective: February 1994 Supersedes I.L. 41-137.2D, Dated February 1973 ( )Denotes Change Since Previous Issue. Type KRV Directional Before putting relays into service,
More informationIndividual breakers in separate enclosures can be applied in low voltage distribution systems through 600 volts Ac, 50/60 Hertz.
Page 2 Introduction The Westinghouse Systems Pow-R Breaker, the worlds first encased power breaker, is not just an extension of existing technology. It represents the biggest breakthrough in circuit protection
More informationAC Relays. Type IC5182. Ordering Information. Control Power Requirements. Contact Ratings (Amperes)
AC Relays Type IC5182 Series N147 Overload Relays are of the magnetically operated self reset type, designed for use on A.C. or D.C. motor starters and controllers for Navy Service A applications. Specification
More informationDETAIL SPECIFICATION SHEET
INCH-POUND MIL-DTL-17361/4B(SH) 19 September 2006 SUPERSEDING MIL-C-17361/4A(SH) 13 March 1995 DETAIL SPECIFICATION SHEET CIRCUIT BREAKERS, AIR, ELECTRIC, INSULATED HOUSING (SHIPBOARD USE) TYPES AQB-A101,
More informationType CDG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay
Type DG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay Type DG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay DG 14 drawn out from the case The type DG 14 relay is a heavily damped
More informationABB Automation Inc. Substation Automation and Protection Division Coral Springs, FL 33065
ABB Automation Inc. Substation Automation and Protection Division Coral Springs, FL 33065 Instruction Leaflet Effective: October 1999 Supersedes I.L. 41-133R, Dated August 1998 ( ) Denotes Changed Since
More informationTECHNICAL SPECIFICATIONS OF PCC PANEL
S. no. TECHNICAL SPECIFICATIONS OF PCC PANEL Technical parameters AS PER SPECIFICATION CONSTRUCTIONAL FEATURES TO BE FILLED BY THE SUPPLIER 1 Manufacturer s name To be specified by supplier 2 Rated operational
More informationProtectors. 35mm DIN rail snap-on mounting. Wide range of accessories
Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified
More informationABB. Type CRQ Directional Negative Sequence Relay for Ground Protection B 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION CAUTION
ABB Instruction Leaflet 41-163.2B Effective: January 1977 Supersedes I.L. 41-137.3A, Dated September 1974 ( ) Denotes Change Since Previous Issue Type CRQ Directional Negative Sequence Relay for Ground
More informationL. Photo. Figure 2: Types CA-16 Relay (rear view) Photo. Figure 1: Types CA-16 Relay (front view)
Figure 1: Types CA-16 Relay (front view) Photo Figure 2: Types CA-16 Relay (rear view) Photo 2 Sub 5 185A419 Sub 6 185A443 Figure 3: Internal Schematic of the Type CA-16 bus Relay or CA-26 Transformer
More informationSpecification Guide. for RMAX. Direct Replacement. AC Low Voltage. Power Circuit Breakers
Specification Guide for RMAX Direct Replacement AC Low Voltage Power Circuit Breakers Table of Contents 1.0 General Work Scope...3 2.0 Standards... 3 3.0 Supplier Qualifications... 3 4.0 Mechanical and
More informationModular Metering - Trip Unit for >1200A Mains DEH41187 Application Guide
GE Industrial Solutions Modular Metering - Trip Unit for >1200A Mains DEH41187 Application Guide TABLE OF CONTENTS Description Page 1.0 General Information...... 1 1.1 Protection..... 1 2.0 UL Listed Devices...
More informationGE Consumer & Industrial Electrical Distribution. Power Break II. Insulated Case Circuit Breakers
GE Consumer & Industrial Electrical Distribution Power Break II Insulated Case Circuit Breakers Table of Contents Power Break II Circuit Breakers......................... 3 Basic Configuration.......................................
More informationA system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.
General Unit substations shall be 500 kva minimum, 1500 kva maximum unless approved otherwise by the University. For the required configuration of University substations see Standard Electrical Detail
More informationTABLE I 60 CYCLE BURDEN OF THE CVD RELAY AT CONTINUOUS RATING
the voltage unit contacts, this effect is negligible. 3.2 Trip Circuit The main contacts will close 30 amperes at 250 volts dc and the seal-in contacts of the indicating contactor switch (ICS) will carry
More informationManual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X
Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and
More information~
Table Of Contents Wire 00 Vacuum Top Adjustment Auxiliary Coil General Guide Mechanical Bottle Bottom Drawout and Assemblies Assemblies Harnesses Assemblies Guide Terminal information 800 Bottle Contactor
More informationForm G5-1 PACIFIC GAS AND ELECTRIC COMPANY GENERATION PRE-PARALLEL INSPECTION
Form G5-1 Page 1 of 3 PACIFIC GAS AND ELECTRIC COMPANY PG&E LOG WO/GM D&C Name of Project: Location: Transmission Line No. Distance Circuit No. 1. Maintenance Data: Generation Customer s Maintenance Chief
More informationNMC Combination Line Starters and Enclosures
NMC Combination Line Starters 600VAC Heavy uty atertight eatherproof Applications: NMC combination magnetic line starters are for use in across-the-line motor starting, motor disconnect, motor and line
More informationGENERAL. ELECTRIC RENEWAL PARTS IC302E HIGH VOLTAGE CONTACTORS. EA A-2300V IEl A-4800V l:c a-sooov
RENEWAL PARTS IC0E HIGH VOLTAGE CONTACTORS EA7----700A-00V IE7 ----700A-800V :C7----700A-SOOOV PARTS RECOMMENDED FOR NORMAL STOCK (a forms) Ref. Cataog Num' )er ---------- 7 5A58P 8 5A9G, 9B8G 5A9G 77B5P
More informationTimer Relays - Fixed & Adjustable
Solid State Solid State relays are suitable across all applications where reliability is paramount. Unlike conventional relays, Solid State relays use electronics in place of traditional contacts, allowing
More informationLow-Peak 600V Class RK1
LPS-RK 600Vac/300Vdc, 1 10-60A, Dual Element, Time-Delay Fuses Dimensions - in 5" (± 0.31) 5.5" (± 0.31) Available with easyid open fuse indication 1/10 to 30A 0.81" (±0.008) 35 to 60A 1.06" (±0.008) Description:
More informationHorizontal Circuit Switchers
> Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving
More informationHorizontal Circuit Switchers
> Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving
More informationControl Transformers
J., APRJL, 1983 SUP RSEPES1/8111TION Control Transformers FILE: Control Products Catalog Machine Tool Transformer Disconnects CONTENTS Description Class Pages General............ 97... 23 Application Data.........
More informationControlled Power HSN High Speed DC Circuit Breakers
Controlled Power HSN High Speed DC Circuit Breakers Each CP Type HSN circuit breaker unit can consist of either a wheeled truck and housing or be panel mounted. The circuit breaker can be mounted on the
More informationABB Power T&D Company Inc. Relay Division Coral Springs, FL Allentown, PA. Non-Directional, Single Phase Adjustable Time Delay Device No.
September, 1990 Supersedes Descriptive Bulletin 41-100, pages 1-4, dated June, 1989 Mailed to: E, D, C/41-100A Hi-Lo co induction-disc type overcurrent relays are activated when the current in them exceeds
More informationBulletin 1494V Variable Depth, Flange Operated Disconnect Switch Kits for 400 and 600 Amperes (Series A) Switches
Bulletin 494V Variable Depth, Flange Operated Disconnect Switch Kits for and Amperes (Series A) Switches ATTENTION: To prevent electrical shock, disconnect from power source before installing or servicing.
More informationInstructions for Replacing
e Instructions for Replacing Vacuum Bottle Subassemblies a on Type SJA, SJS and SJO 360 Amp Contactors l.l. 16-200-348 This l.l. includes illustrations and instructions for replacing vacuum bottle subassemblies
More informationSIEMENS. Series 8100oT Vacuum Controllers. www. ElectricalPartManuals. com. Bulletin CC
c c SIEMENS Series 8100oT Vacuum Controllers Bulletin CC3802-02 Technological Development Vacuum technology has developed rapidly in recent years and is becoming widely accepted for medium voltage motor
More informationHCI General Purpose Disconnects
30 AMPERES 1oo AMPERES C General Purpose Disconnects AMPERES 0 AMPERES Quality Designed... Thoroughly Tested orsepower Rated 30-0 Amperes, 240, 480 and 0 Volts AC, 2 Volts DC with adjustable operating
More informationFile E14900 Project 98NK January 11, 1999 REPORT MOTOR CONTROLLERS MAGNETIC. Siemens Energy & Automation Inc. Batavia, IL
File E14900 Project 98NK40464 January 11, 1999 REPORT on MOTOR CONTROLLERS MAGNETIC Siemens Energy & Automation Inc. Batavia, IL Copyright 1999 Underwriters Laboratories Inc. Underwriters Laboratories
More informationSpecification for 70mm pole pitch Air circuit breaker up to 1600 A
Specification for 70mm pole pitch Air circuit breaker up to 1600 A Protective device for low voltage electrical installation Last update :2011-07-08-1 - Table of contents: 1 General...3 2 Compliance with
More informationHGA. Hinged Armature Auxiliary. Hinged armature auxiliary relay to perform auxiliary functions in AC and DC circuits.
HA Hinged Armature Auxiliary Hinged armature auxiliary relay to perform auxiliary functions in and circuits. eatures and Benefits Molded case with 4 mounting options Drawout case available Applications
More informationA. Submit manufacturer's literature and technical data before starting work.
SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop
More informationDANGER. Instruction Bulletin WARNING. Shunt Trip Kit for Manual DS/DSL Circuit Breakers POWER ZONE III Low Voltage Switchgear Class 6035 INTRODUCTION
Instruction Bulletin Bulletin No. 44027-017-01 Middletown, OH USA Class 6035 INTRODUCTION This bulletin contains instructions for adding a shunt trip assembly to a manual DS/DSL circuit breaker and modifying
More informationMulti-Pak Group Control
Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder
More informationGeneral data 5/37. Overview
General data Overview Benefits High short-circuit breaking capacity in the feeder Optimum usability in motor feeders for the special voltages 440 V, 480 V, 0 V and 690 V Compact design The are available
More informationMichigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE
PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationBILL OF MATERIAL 2 C EA SP CURRENT TRANSDUCER BI-DIRECTIONAL, MV INPUT, MA OUTPUT, 125VDC POWER SUPPLY SMC
BILL OF MATERIAL WORK ORDER NUMBER : G6025-01 PURCHASER : TRACTION POWER SYSTEMS PO# : NTP USER : WMATA LOCATION : WASHINGTON, DC PAINT CODE: 061-T/061-T/B/S EQUIPMENT ID : FARRAGUT NORTH SUBSTATION-A02
More informationSection SWITCHBOARDS. Introduction. Part 1 - General. Related Work
Section 16435 - SWITCHBOARDS Introduction Part 1 - General Related Work Section 16070 Seismic Anchorage and Restraint Section 16075 Electrical Identification Section 16080 Power Distribution Acceptance
More information2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4
CHAPTER ELECTRICAL 2 INSTALLATION Contents of this Chapter... 2.1 Warnings & Agency Approvals..................2 2 2.1.1 Isolation..............................................2 2 2.1.2 Electrical Power
More informationMotor Control. Motor Control Electrical Aftermarket Products and Services Contents
June 00 Aftermarket Solutions, Ref. No. [] - CA0000E Contents Description Page Contactors, Starters & Brakes................................... - Product Description.........................................
More informationEntelliGuard Power Circuit Breaker Accessories. Network Interlock for Ampere Circuit Breakers. Introduction. Operation
DEH41118 Installation Instructions R01 R02 g EntelliGuard Power Circuit Breaker Accessories Network Interlock for 3200-5000 Ampere Circuit Breakers Introduction The Network Interlock provides a means of
More information6300A 15 Optibreak B1 & B2 Optibreak B1 & B2 50/60 Hz Ue Icu [v] [ka] 415 65 690 40 4h 4i 1. Open / close Indication 2. Charge and Discharge Indicator 3. Release the reset button 4. Laser Nameplate
More informationR-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism
R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism R-MAG Features: Low maintenance 10,000 mechanical operations (five times ANSI requirements) Simple magnetic actuator Vacuum interruption Definite
More informationPower Break II Circuit Breaker Accessories Motor Operator Mechanism
g GEH 6281E Power Break II Circuit Breaker Accessories Motor Operator Mechanism Introduction The Motor Operator Mechanism, shown in Figure 1, can be installed in 800 4000 A frame Power Break II circuit
More informationInstructions for Installation, Operation and Maintenance of Low Voltage Power Circuit Breakers Types DSII and DSLII
Effective July 2010 Supersedes July 1997 IB694C694-02 Instructions for Installation, Operation and Maintenance of Low Voltage Power Circuit Breakers Types DSII and DSLII Effective July 2010 PURPOSE This
More information