1 i BBC BROWN BOVERI Type LK and LKE 800 thru 4200 Amperes Type LKD 800 and 1600 Amperes 600 Volts RP 6118A Renewal Parts 1-T -E Low-Voltage Power Circuit Breakers Brown Boveri Electric
2 RP A Page 2 Introduction TABLE OF CONTENTS Recommended Quantities Ordering Instructions Circuit Breaker Components Accessories Cradle Components The photographs reproduced in this bulletin are furnished only to serve as a guide in the identification of assemblies and parts, and do not purport to cover all details or variations in equipment 10-12
3 INTRODUCTION These renewal parts apply to types LK and LKE Circuit Breakers with AC continuous ratings of 800, 1600, 2500, 200, and 4200 amperes and type LKD with AC continuous ratings of 800, and 1600 amperes A supply of renewal parts is recommended to insure proper and timely maintenance for normal operation of the circuit breakers The minimum quantity of assemblies and items recommended in this bulletin is predicated on infrequent replacement of parts based on accumulated tests and operating experience Total assemblies are recommended for fast replacement, to return the breaker to service as quickly as possible For assistance, contact the nearest District Office RECOMMENDED QUANTITIES 1 Minimum Recommended Quantities are based on the following categories of service: Domestic One (1) complete set for each ten (10) circuit Foreign Note: breakers or fraction thereof installed for each type and rating One (1) complete set for each five (5) circuit breakers or fraction thereof installed for each type and rating Renewal Parts Listing cover all types and ratings of circuit breakers Use caution in selecting parts to assure they are applicable to the circuit breaker(s) on hand 2 The parts listed cover an indefinite period of time With normal duty and maintenance, replacement will be infrequent Where continuity of service is mandatory, a spare circuit breaker of each type and rating is recommended ORDERING INSTRUCTIONS RP Page When ordering, always specify circuit breaker type(s) and serial number(s) from the nameplate(s), in addition to the quantity, description, and ordering number of each assembly or part, as applicable Example: To order Lower Terminal and moving Contact assemblies for a type LK 8 Drawout Circuit Breaker, specify the following: For a type LK 8 Drawout Circuit Breaker Serial No 54000A Quantity Number T7 Lower Terminal and Moving Contact Assembly Only those parts that normally require replacement have been shown and listed If the part(s) required are not listed, completely describe the part(s), using reference in the instruction sections, actual photographs or a sample ADDITIONAL INFORMATION For FO R PRICES AND TECHNICAL INFORMATION, CONTACT OU R NEA REST DIST RICT OFFICE Installation/Maintenance Instructions for 1-T-E Low Voltage Power Circuit Breakers see IB For Installation/Maintenance Instructions for 1-T-E Low Voltage AC Metal Enclosed Power Switchgear see IB 117-1
4 RP Page 4 CIRCUIT BREAKER COMPONENTS Description of Assembly or Part Upper Terminal Assem (includes stationary main & arc contact) Lower Terminal & Moving Cont Assem (includes moving main & arc contacts) Moving Contact Assem (Bridge Blade, includes main & arc contacts) Operating Mechanism Small Large Phase Sensor Arc Chute Man Oper Elec Oper Man Oper Elec Oper 200A 800A 1600A 2500A 000A 200A 4000A 4200A Fig Ref 1A C Not Illustrated 2A C 2C Not Illustrated A 8 4A 4A 5A 58 6A 68 Quantities Per Type CCLnNN -NM<:t CIOWWWW w CCLnNN co-nm<:t Fused cc coco I I Ordering Number T7 T8 T T4 T10 T T7 T8 T T4 T5 T6 T10 T K K T T4 T5 T K K5 K K6 K7 K8 K9 K T2 T
5 RP Page 5
6 RP Page 6 CIRCUIT BREAKER COMPONENTS (Continued) Add Suffix to Oreding Number DC 50/60Hz Quant Per > > > Circuit """ co 0 N """ Description for Types Fig to Ordering > > > > Breaker > > I!) 0 0 co LK, LKE and LK D Number (Options) Ref """ co N I!) N 0 N """ I!) N """, N, N N """ I!) Shunt Trip Assem 7A T9 T6 T7 T8 T1 T T 1 (Eiec Oper & Option on Man Oper) Close Coil Assem SA T6 T7 T8 T1 T T 1 (Eiec Oper Only) "Y" Relay Assem 9A T6 T7 T8 I T1 T T - 1 (Eiec Oper Only) Motor Assem 10A T8 T6 T7 TG T7 T7 1 (Eiec Oper Only) Undervoltage Trip Device 11A T9 T6 T7 T8 T1 T2 T T4 T5 ( 1) (Option) UV Lockopen T9 (Option for UV Device) ( 1) Uv Trip defeator T7 (Option for UV Device) ( 1) Close & Trip Switch 12A A (Option for Elec Oper) ( 1) Alarm Switch (Auto Trip) 1A A (Option) ( 1 or 2) Auxiliary Switch (L) 14A T1 Elec, or Man Oper with Shunt Trip 1 Limit Switch (LS1 &) 15A T2 Electrical Operation Only 1 Limit Switch (LS-2) 15B T1 Electrical Operation Only 1 Motor Disconnect Switch 16A A Electrical Operation Only 1 Operation Counter 17A A (Option) ( 1) Secondary Disconnect 18A T1 No Guide As Req'd Moving (7Contact) 18 B T Single Guide As Req'd 18C T4 Double Guide As Req'd
7 RP Page 7
8 RP Page 8 CIRCUIT BREAKER COMPONENTS (Continued) Quantity per type DESCRIPTION Fig Ordering LKD 8 LKD 16 Ref Number Open Fuse Trip Device A T1 Amp Trap Fuse* 00A A1 *Warning: Fuse is current limiting and must be coordinated with LSS Trip Device (Listed is Type 55 AL, Style "Y" Form 480 AMP Trap) 400 A2 600 A 800 A A A A A AS A Basic No Ground Add Suffix to Basic Order No (Sensor Ratings) Quantity Trip With Ground Trip Per With Fig Order 200A to 200A BOOA 1600A 2500A Breaker Type Description Type Ref No 4200A 200A 4200A Solid State Trip Unit LSS1 21A T01 T11 T21 T1 T41 T51 TG1 LSS 1G (without targets) LSS2 G T (without ground) LSS T04 T11 T14 T21 T24 T1 T4 Circuit Ground LSS-4G LSS5 G1107- T05 T12 T15 T22 T25 T2 T5 LSS-G LSSG G1107- TOG T1 T1G T2 T26 T TG 1 LSS-6G Solid State Trip Unit LSS4 - G T04 T11 T14 T21 T24 T1 T4 LSS-4G (with targets) LSS T05 T12 T15 T22 T25 T2 T5 LSS-5G (without ground) LSSG G TOG T1 T1G T2 T2G T TG LSS-GG Auxiliary Static Units (optional) - Control Power Not available for LSS1 & VAC 125VAC 120VAC 250VDC 48VDC Load Alarm 22A G110G8 - T01 T01 T01 T01 T48 Ground Trip Alarm 22A G110G8- T02 T02 T02 T02 Remote Neutral Sensor T49 ircuit Breaker Sensor Rating (Amperes) Mounting I D Bus Window two 800 1GOO Bars (max) Width (4-wire ground) G K1 K2 K K4 K5 KG K7 K8 (1)Y,"x4" 4%" 1 Control Cable Assembly 2A K1 K2 K K4 K5 ()Y"xG" GY" Standard (9 wire) G T01 T0 Special (for use with 1 Load or G Trip Alarm) G T02 T04 Magnetic Latch 24A T15 ALL RATINGS 1 Trip Unit Transparent Cover - G A ALL RATINGS 1 (Remote)
9 , 1 RP Page 9
10 RP Page 10 ACCESSORIES: Fig Ordering Type Description Ref Number LK, LKE, LKD, Racking Crank 25A T6 LK, LKE, LKD 8 & 16 Lifting Yoke T7 LK, LKE 25 to 42 Lifting Yoke 25C T8 CRADLE COMPONENTS: Shutter Assem Quantities Per Type: Fig LK, LKE, LKD LK, LKE 25 to 42 Ordering Description Ref 8 or 16 Number Large 26A T2 Small T1 Position Indicator Kit (Optional) 27A T1 MOC Switch Kit (Optional) T14 Actuator 28A i Operates Connected Position T11 Operates Connected & Test Position T12 Switch Includes Mounting & Crank Contact ( L2) or T1 8 Contact ( L2) Max (shown) T2 TOC Switch Kit (Optional) 29A 4 Contact ( L2) Standard* T1 8 Contact ( L2) Standard* T2 4 Contact Special** T 8 Contact Special** T4 4 Contact - Standard and T5 Contact - Special (Shown) * Operates between Test and Connected Positions ** Operates between Test and Disconnect Positions Auxiliary Switch Assem(Optional) 0A 4 Contact (L2) (Shown) K1 8 Contact (L2) K1 Secondary Disconnect (As Required) Stationary (7 Contact) 1A 0 to 4 0 to T2 Insulation Strip-Secondary Disconnect "TP" Function - (As Required) (As Required) A Short Contact-Secondary Disconnect "OP" Function - (As Required) (As Required) A Transparent Door Mounted Position Indicator Cover (Optional) A Emergency Trip Button- Door Mounted (Optional) T1 ---
11 ' t RP Page 11
12 RP Page 12 CRADLE COMPONENTS Description Ref 8 or 16 Current Transformer: Quantities Per Type: Fig LK, LKE, LK D LK, LKE 25 to 42 Ordering Number Type LKM-1 100/5 A 2A Oto K1 150/5 A K2 200/5 A K 00/5 A K4 400/5 A K5 500/5 A K6 600/5 A K7 800/5 A K8 1000/5 A K9 1200/5 A K /5 A K /5 A K /5 A K1 2500/5 A K14 Type LKM /5 A 28 Oto K1 2500/5 A K2 000/5 A K 4000/5 A K4 5000/5 A K5 6000/5 A K6
13 NOTES RP Page 1
14 RP Page 14 NOTES
15 NOTES RP Page 15
16 BBC BROWN BOVERI Brown Boveri Electric, Inc Switchgear Products Division Spring House, PA Supersedes IB 6117 Issue A Printed in USA M CMC 68
BBC. Renewal Parts. I-T-E Low-Voltage Power Circuit Breakers
BBC BROWN BOVERI RP 6..2.8-2C Renewal Parts I-T-E Low-Voltage Power Circuit Breakers Type K-000, 4000, 0008, and 40008 Stationary and Drawout Mounted 000 and 4000 Amperes 600 Volts RP 6..2.8-2 Page 2 Table
More informationBBC. Installation/Maintenance Instructions I-T-E Low-Voltage Power Circuit Breakers
BBC BROWN BOVERI IB 6.1.1.7-1E Installation/Maintenance Instructions I-T-E Low-Voltage Power Circuit Breakers...,. Type LK and LKE 800 thru 4200 Amperes Type LKD 800 and 1600 Amperes 600 Volts Model-1
More informationPage 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut
Page 1 Supersedes Renewal Parts Data 33-790-1G pages 1-20 dated December, 1988 Mailed to: C, D, E/33-700 Westinghouse DS and DSL Low Voltage Power Circuit Breakers and Cell Parts Contents Pages DS Breaker
More informationInstruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035
Instruction Bulletin 4402-997-0 February 999 Middletown, OH, USA DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 605 DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker
More informationRENEWAL PARTS AK-2-15 AK-2-25 AK-3-25 AKF-2-25 AK-2A-15 AK-2A-25 AK-3A-25 AKF-2A-25 AKU-2-25 AKU-3-25 AKU-2A-25 AKU-3A-25
Data ubject to change without notice. RENEWAL PARTS POWER CIRCUIT BREAKERS TYPES 225 AMP FRAME SIZE 00 AMP FRAME SIZE GEF-449G Supersedes GEF-449F AK-2-5 AK-2-25 AK-3-25 AKF-2-25 AK-2A-5 AK-2A-25 AK-3A-25
More informationSelection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker
Selection and Application Guide Supplement WL UL1066 4-Pole Circuit Breakers usa.siemens.com/wlbreaker WL Power Circuit Breaker Table of Contents Ratings for UL 1066 (ANSI C37) Circuit Breakers Frame size
More informationFrame Sizes: AKJ/ AKJT I AKJU-50 and AKR/ AKRU-30/ 50, AKRT-50
RENEWAL PARTS LOW VOLTAGE POWER CIRCUIT BREAKERS Frame Sizes: AKJ/ AKJT I AKJU-50 and AKR/ AKRU-30/ 50, AKRT-50 GEF-4527F Supersedes GEF-4527E TABLE A. INDEX OF BREAKER MODELS COVERED BY THIS PUBLICATION
More informationDEF 005. WavePro Power Circuit Breakers A Frames, Vac. Renewal Parts
g DEF 005 WavePro Power Circuit Breakers 3200 5000 A Frames, 240 600 Vac Introduction This guide contains a listing of the parts and assemblies that are available as replacement parts for WavePro 3200
More informationMedium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION
Medium Voltage Standby non-paralleling Control 1. GENERAL GUIDE FORM SPECIFICATION A. The requirements of the contract, Division 1, and part 16 apply to work in this section. 1.01 SECTIONS INCLUDE A. Medium
More informationControlled Power HSN High Speed DC Circuit Breakers
Controlled Power HSN High Speed DC Circuit Breakers Each CP Type HSN circuit breaker unit can consist of either a wheeled truck and housing or be panel mounted. The circuit breaker can be mounted on the
More informationwww. ElectricalPartManuals. com GENERAL. ELECTRIC RENEWAL PARTS METAL-CLAD SWITCHGEAR TYPES M-26 AND M-36 GEF-4351C Supersedes GEF-4351B
Data subject to change without notice. RENEWAL PARTS METAL-CLAD SWTCHGEAR TYPES M-26 AND M-36 ORDERNG NSTRUCTONS 1. Always specify the complete nameplate data of the equipment. GEF-4351C Supersedes GEF-4351B
More informationDESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5
DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 1.1. APPLICABLE PUBLICATIONS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements, and errata), form a part of this
More informationLow Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear
13 Low Voltage Switchgear Siemens Type WL low voltage metal-enclosed switchgear is designed, constructed and tested to provide superior power distribution, power monitoring and control. At the heart of
More informationGEF Renewal Pans. low Vohage Power Circuit Breakers. Type AKR-30S and AKRU-30S. www. ElectricalPartManuals. com
-- GEF-6005 Renewal Pans low Vohage Power Circuit Breakers Type AKR-30S and AKRU-30S INTRODUCTION This manual provides a listing of the parts and assemblies that are availle as replacement parts for low
More informationwww. ElectricalPartManuals. com
Instructions for Parcel-Line Type DH-P Circuit Breakers with Post Insulator Type Pole Units (Supplements I. B. 32-253-2) Westinghouse Electric Corporation Switchgear Division, East Pittsburgh, Pa. 15112
More informationMichigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE
PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationInstructions for Installation, Operation and Maintenance of Low Voltage Power Circuit Breakers Types DSII and DSLII
Effective July 2010 Supersedes July 1997 IB694C694-02 Instructions for Installation, Operation and Maintenance of Low Voltage Power Circuit Breakers Types DSII and DSLII Effective July 2010 PURPOSE This
More informationwww. ElectricalPartManuals. com POWER CIRCUIT BREAKERS TYPES AK-2/3/2A/3A-50, AKU-2/3/2A/3A-50, AKT-2/3/2A/3A-50 GENERAL fj ELECTRIC
ORDERNG NSTRUCTONS. Always specify complete nameplate data of the breaker. 2. Specify the quantity, catalog number (if listed), reference number (if listed), description, and this bulletin number. 3. Standard
More informationInstallation Sheet January, 2016 Supersedes February, 2013
s Installation Sheet January, 016 Supersedes February, 013 E87010-A0104-T003-A6-CLM0 Lighting and Heating Contactor 30 Amp, 3, 4, 5 Pole Magnetically Latched Description Magnetically latched CLM lighting
More informationK-Line Plus Types KP-32, KPE-32, KP-40 and KPE-40
IB 6.2.11.1-2B Installation/Maintenance Instructions Low Voltage Power Circuit Breaker K-Line Plus Types KP-32, KPE-32, KP-40 and KPE-40 ABB Power T&D Company Inc. Distribution Systems Division Table of
More informationSection SWITCHBOARDS. Introduction. Part 1 - General. Related Work
Section 16435 - SWITCHBOARDS Introduction Part 1 - General Related Work Section 16070 Seismic Anchorage and Restraint Section 16075 Electrical Identification Section 16080 Power Distribution Acceptance
More informationK-Line Plus Type KP-8 thru KP-20
IB 6.2.11.1-1B Installation/Maintenance Instructions Low Voltage Power Circuit Breaker K-Line Plus Type KP-8 thru KP-20 ABB Power T&D Company Inc. Distribution Systems Division CONTENTS PAGE INTRODUCTION...3
More informationwww. ElectricalPartManuals. com RENEWAL PARTS DATA Westinghouse Electric Corporation WESTINGHOUSE EQUIPMENT FOR FURNISHED TO
RENEWAL PARTS DATA FOR WESTINGHOUSE EQUIPMENT FURNISHED TO WESTINGHOUSE ELECTRIC CORPORATION Sharon Plant Sharon Pennsylvania Purchaser's Order C&E-D-44252 G.O. XY-9286-UY-UR - S.O. 2-Y-774 SWITCHGEAR
More informationTable Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.
-174 Series C Molded Case Circuit s July 7 Molded Case Switches Refer to Eaton for UL listed, series tested Molded Case Switch application data. Table -278. Molded Case Switches Cont. Amp Rating at 40
More informationPoweMr' With 18 Mechanism '. 1 . / ,, ( c :11t
) rvac Vacuu m Circuit. Breaker PoweMr' With 8 Mechanism L- '.. /,, ( (' p c :t ) FRONT VIEW,. 0 3 Fig. Front View of Breaker with Front Cover 3. COUNTER 0. INTERRUPTER ASSEMBLY Fig. 2 Front View of Breaker
More informationBussmann series Quik-Spec Power Module Switch elevator disconnect
Supersedes January 2016 Agency information UL 98 enclosed and dead-front switch - Guide WIAX, WIAX7 (Canada), File E182262 culus, NEMA 1, UL 50, Listed enclosure cul per Canadian Standards C22.2, No. 0-M91-CAN/
More informationA system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.
General Unit substations shall be 500 kva minimum, 1500 kva maximum unless approved otherwise by the University. For the required configuration of University substations see Standard Electrical Detail
More informationwww. ElectricalPartManuals. com Cutler-Hammer Power Breaker Center Renewal Parts for Low Voltage Power Circuit Breakers Types DB, DBL and DBF
New Information Control Relay Auxiliary Switch Operating Mechanism CutlerHammer Power Center 10 Maxwell Avenue Greenwood, SC 29646 1877276979 Closing Solenoid 2254 Renewal Parts for Low Voltage Power Circuit
More informationHorizontal Circuit Switchers
> Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving
More informationHorizontal Circuit Switchers
> Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving
More informationABB Power T&D Company Inc. Relay Division Coral Springs, FL Allentown, PA. Non-Directional, Single Phase Adjustable Time Delay Device No.
September, 1990 Supersedes Descriptive Bulletin 41-100, pages 1-4, dated June, 1989 Mailed to: E, D, C/41-100A Hi-Lo co induction-disc type overcurrent relays are activated when the current in them exceeds
More informationSIEMENS. Series 8100oT Vacuum Controllers. www. ElectricalPartManuals. com. Bulletin CC
c c SIEMENS Series 8100oT Vacuum Controllers Bulletin CC3802-02 Technological Development Vacuum technology has developed rapidly in recent years and is becoming widely accepted for medium voltage motor
More informationUsing new Magnetically Actuated Vacuum Interrupter technology for safe and reliable medium voltage circuit breaker switching in mines
Using new Magnetically Actuated Vacuum Interrupter technology for safe and reliable medium voltage circuit breaker switching in mines Abstract: The development of the magnetically actuated vacuum interrupter
More informationMetal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents
January 2003 Vol. 1, Ref. No. [1011] -1 Medium Voltage Metal-Enclosed Switches Contents Description Page MVS................................... -2 and Breaker MSB........................ -3 Metal-Enclosed
More informationwww. ElectricalPartManuals. com Type AM Magne-Biast Circuit Breakers RENEWAL PARTS
RENEWAL PARTS Ordering Instructions 1. Always specify the complete nameplate data of the breaker. 2. Specify the quantity, catalog number (if listed), reference number (if listed) description, and this
More informationFOR PRICES ON DSII and DSLII BREAKERS, REFER TO PRICE LIST PL.22B.01.P.E
Supersedes PL.44B.04.P.E Dated September 1998 600 Volts AC Maximum 200 ka, RMS Sym. Short Circuit Maximum 800-5000 Amps Continuous Effective: October 1999 Page 1 Index Page Table Description/Application...
More informationType SOQ Negative Sequence Time Overcurrent Relay
ABB Power T&D Company Inc. Power Automation & Protection Division Coral Springs, FL Allentown, PA April 1998 Supersedes DB dated August 1991 Mailed to: E,D, C/41-100B For Protection of Rotating Machinery
More informationSECTION DC POWER SUPPLY/BATTERY CHARGER
SECTION 26 33 05 PART 1 - GENERAL 1.1 THE REQUIREMENT A. The CONTRACTOR shall provide the single-phase heavy-duty industrial battery charger and all accessories required, complete and operable, in accordance
More informationVacClad-W type VCP-W 5 and 15 kv, 36-inch-wide switchgear components
Supersedes July 2002 Contents Page Procedure for identifying parts... 2 Customer ordering instructions.... 2 Distributor ordering instructions.... 2 Front panel components.... 3 Breaker pan assembly....
More informationSECTION MOTOR CONTROL
SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters
More informationSpecification for 70mm pole pitch Air circuit breaker up to 1600 A
Specification for 70mm pole pitch Air circuit breaker up to 1600 A Protective device for low voltage electrical installation Last update :2011-07-08-1 - Table of contents: 1 General...3 2 Compliance with
More informationA - Add New Information C - Change Existing Information D - Delete Information. Page 7. Delete the fourth paragraph beginning CAUTION
ABB Effective: November 1990 This Addendum Supersedes all Previous Addenda Addendum to Instruction Leaflet 41-137.3H Type KRD-4 Directional Overcurrent Ground Relay A - Add New Information C - Change Existing
More informationType CRN-1 Reverse Power Relay 50 and 60 Hertz
ABB Automation Inc. Substation Automation and Protection Division Coral Springs, FL 33065 Instruction Leaflet 41-251.2P Effective: June 1991 Supersedes I.L. 41-251.2N Dated April 1988 ( )Denotes Change
More informationRENEWAL PARTS I C302AA A-2 300V AB A-4800V A C A -SOOOV PARTS RECOMMENDED FOR NORMAL STOCK
NGrE: RENEWAL PARTS IC0A HIGH VOLTAGE CONTACTORS I C0AA 00A 00V AB00A800V A C 00A SOOOV PARTS RECOMMENDED FOR NORMAL STOCK The current is identified by the number following the voltage letter in the IC
More informationMedium Voltage Equipment 5-15 kv GM-SG and 38 kv GM38 Metal-Clad Switchgear General
13 SWITCHGEAR Medium Voltage Equipment -1 kv GM-SG and 38 kv GM38 Metal-Clad Switchgear General Overview Features Siemens, 7, 1 and 38kV class medium voltage, one- or two-high vacuum circuit breaker switchgear
More informationwww. ElectricalPartManuals. com lncoming-6900 through 69,000 volts Outgoing-2400 through 13,800 volts Ratings:
PRIMARY UNIT SUBSTATIONS SECTION 2701 PRIMARY UNIT SUBSTATIONS Ratings: lncoming-6900 through 69,000 volts Outgoing-2400 through 13,800 volts PAGE 1 ---JUNE 1, 1959 DESIGNED AND BUILT TO MEET YOUR OWN
More informationInstallation Sheet January, 2016 Supersedes June 2013
s Installation Sheet January, 016 Supersedes June 01 E87010-A0105-T00-A6-CLM0 Lighting and Heating Contactor 60, 100, 00 Amp,, 4, 5 Pole Magnetically Latched Description Magnetically latched CLM lighting
More informationCR193 B,C,D and E Vacuum Limitamp * Contactors
GE Industrial Solutions CR19 B,C,D and E Vacuum Limitamp * Contactors Renewal Parts Bulletin Table of Contents General Information... Contactor Matrix... 4 Mounting Plates, Pull Handle, Interlock Driver
More informationDS/DSII Low Voltage Switchgear. Renewal Parts. Cutler-Hammer. Renewal Parts. Effective: October Page 1
New Information Supersedes Data 33-790-1H, dated October 1996 DS/DSII Low Voltage Switchgear Page 1 DS Switchgear Assembly DSII Switchgear Assembly Contents Pages DS Switchgear (Front View) 2 DSII Switchgear
More informationPOWER-ZONE 4 Low Voltage Metal-Enclosed Drawout Switchgear with MASTERPACT NW Low Voltage Power Circuit Breakers
POWER-ZONE 4 Low Voltage Metal-Enclosed Drawout Switchgear with MASTERPACT NW Low Voltage Power Circuit Breakers Class 6037 CONTENTS Schneider Electric Brands Description Page Product Description..................................................
More informationParts Manual. Transfer Switch. OTPCB (Spec A) 150/225/260 Amps. English Original Instructions (Issue 4)
Parts Manual Transfer Switch 50/225/260 Amps OTPCB (Spec A) English Original Instructions -203 962 0228 (Issue ) This catalog covers models produced under the Cummins /Onan and Cummins Power Generation
More informationA. Submit manufacturer's literature and technical data before starting work.
SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop
More information2.0 CONSTRUCTION AND OPERATION 3.0 CHARACTERISTICS K. CO (HI-LO) Overcurrent Relay
41-100K 2.0 CONSTRUCTION AND OPERATION The type CO relays consist of an overcurrent unit (CO), either an Indicating Switch (ICS) or an ac Auxiliary Switch (ACS) and an Indicating Instantaneous Trip unit
More informationData Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931
Data Bulletin 0931DB0101 July 2001 Cedar Rapids, IA, USA Ground-Censor Ground-Fault Protection System Type GC Class 931 09313063 GT Sensor Shunt Trip of Circuit Interrupter Window Area for Conductors GC
More informationInstructions for Replacing
e Instructions for Replacing Vacuum Bottle Subassemblies a on Type SJA, SJS and SJO 360 Amp Contactors l.l. 16-200-348 This l.l. includes illustrations and instructions for replacing vacuum bottle subassemblies
More informationIndustrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw
Industrial Generator Set Accessories Line Circuit Breakers 15-2500 kw Standard Features Single Circuit Breaker Kit with Neutral Bus Bar 15-300 kw Model Shown The line circuit breaker interrupts the generator
More informationINSTRUCTIONS. seconds. the tween the end of the bearing screw and the. top of the shaft. The moving contact is a small silver hemisphere
. L. 41-793 NSTALLATON OPERATON MANTENANCE NSTRUCTONS TYPE CRN REVERSE POWER RELAY FOR MARNE SERVCE CAUTON Before putting relays into service remove all blocking which may have been inserted for the purpose
More informationVacuum Circuit Breaker Type VAD-3
Instruction Bulletin Bulletin 6055-11 Vacuum Circuit Breaker Type VAD-3 4.76 kv, 29 ka (250 MVA) 4.76 kv, 41 ka (350 MVA) 8.25 kv, 33 ka (500 MVA) 15.0 kv, 18 ka (500 MVA) 15.0 kv, 28 ka (750 MVA) 15,0
More informationwww. ElectricalPartManuals. com Instructions for Ground Fault Protection Systems INTRODUCTION SENSOR Fig. 1 Cu"ent Monitor
Instructions for Ground Fault Protection Systems INTRODUCTION The Westinghouse Ground Fault Protection System, when properly installed on a grounded electrical distribution system, will sense and interrupt
More informationPowlVac Type PV STD/CDR Vacuum Circuit Breaker
Instructions PowlVac Type PV STD/CDR Vacuum Circuit Breaker Installation Maintenance Renewal Parts POWELL ELECTRICAL MANUFACTURING COMPANY 8550 MOSLEY DRIVE HOUSTON, TEXAS 77075 USA PHONE (713) 944-6900
More informationDescriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications
Descriptive bulletin Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications General overview Reliable, low maintenance and economical Load Interrupter
More informationCOM Overcurrent Relay
41-102.1B COM Overcurrent Relay Figure 1: COM-5 Class 1E Relay (Front View) 9664A28 Photo Figure 2: COM-5 Class 1E Relay (Rear View) 9664A29 Photo Photo needed here 2 COM Overcurrent Relay 41-102.1B 3
More informationDigitrip Retrofit System for BBC LKD 8 Breakers
Supersedes IL 33-LK8-2 Dated 10/00 Contents Description Page Introduction.............................. 3 Step 1:............................... 4 Step 2:............................... 4 Step 3:...............................
More informationCutler-Hammer. Instructions for Potential Transformer and Auxiliary Control Power Disconnecting Means for Use in Ampgard Lineups, 7.2 kv I.B.
Cutler-Hammer Instructions for Potential Transformer and Auxiliary Control Power Disconnecting Means for Use in Ampgard Lineups, 7.2 kv DANGER HAZARDOUS VOLTAGE. READ AND UNDERSTAND THIS BOOKLET IN ITS
More informationIB PowlVac CDR Vacuum Circuit Breaker. 5kV & 15kV 1200A, 2000A, & 3000A. Powered by Safety
IB-60202 PowlVac CDR Vacuum Circuit Breaker 5kV & 15kV 1200A, 2000A, & 3000A Powered by Safety IB-60202 Contact Information Powell Electrical Systems, Inc. www.powellind.com info@powellind.com Service
More informationDigitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers
Supersedes IL 33-858-4 Dated 05/02 Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers Digitrip Retrofit System for ITE K-3000, Digitrip Retrofit System for ITE K-3000, K-3000
More informationAdvance design OEM L-Frames, cell kits, & enclosures Metal-clad switchgear components OEM catalog & pricing
Advance design OEM L-Frames, cell kits, & enclosures Metal-clad switchgear components OEM catalog & pricing Introduction A modular system of switchgear building blocks and cassettes provide untouchable
More informationwww. ElectricalPartManuals. com INSTRUCTIONS INTERLOCKED MOTOR-DRIVEN OPERATING MECHANISM For No-Load Tap Changers DESCRIPTION OPERATION MAINTENANCE
c PQSITION TRANSMITTER (SYNCROTIE} LOCAL POSITION INDICATOR CARRYOVER CAM a SWITCH MOTO R AB BREAKER I.L. 46-722-2A DESCRIPTION OPERATION MAINTENANCE INSTRUCTIONS INTERLOCKED MOTOR-DRIVEN OPERATING MECHANISM
More informationUniversity of Houston Master Construction Specifications Insert Project Name
SECTION 26 24 14 600 VOLT DRAWOUT SWITCHGEAR PART 1 - GENERAL 1.01 SECTION INCLUDES: A. Individually mounted rear-accessible low voltage switchgear ANSI rated switchgear and low voltage power circuit breakers
More informationMedium Voltage Metal-Enclosed Switches
Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Medium Voltage Switch MVS Product Description............................................. 2 Application Description..........................................
More informationCritical Power Switchboards. Selection and Application Guide
Selection and Application Guide Siemens RCIII (rear connected) switchboards utilizing Siemens Type SB Encased Breakers are a perfect solution for your critical power distribution needs. Whether your installation
More informationUBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5
Page 1 of 5 1.0 GENERAL 1.1 Coordination Requirements.1 UBC Building Operations Electrical Technical Support.2 UBC Energy & Water Services 2.0 REQUIREMENTS FOR COMMISSIONING AND TESTING 2.1 Testing.1 Unit
More informationSelection Guide. Control Circuit and Load Protection
Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature
More informationABB ADVAC TM. INSTALLATION/MAINTENANCE INSTRUCTIONS Medium Voltage Vacuum Power Circuit Breakers and Auxiliary Devices
IB 6.2.13.7-1 1 Rev. 4, June 2000 ADVAC TM INSTALLATION/MAINTENANCE INSTRUCTIONS Medium Voltage Vacuum Power Circuit Breakers and Auxiliary Devices Power T&D Company, Inc. Distribution Systems Division
More informationParts Manual. Transfer Switch. OTPCC (Spec A) 300/400/600 Amps. English Original Instructions (Issue 4)
Parts Manual Transfer Switch 00/00/600 Amps OTPCC (Spec A) English Original Instructions -20 962 0229 (Issue ) This catalog covers models produced under the Cummins /Onan and Cummins Power Generation brand
More informationInterchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI
. Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,
More information~
Table Of Contents Wire 00 Vacuum Top Adjustment Auxiliary Coil General Guide Mechanical Bottle Bottom Drawout and Assemblies Assemblies Harnesses Assemblies Guide Terminal information 800 Bottle Contactor
More information920 Remote Control Switches
920 Remote Control Switches REMOTE CONTROL SWITCHES Service Bulletin This service bulletin for ASCO 920 Remote Control Switches explains how to replace the main s, operator coil, control s, and how to
More informationPowered by Safety 01.4IB.77000B PowlVac-ND Vacuum Circuit Breaker
Powered by Safety PowlVac-ND Vacuum Circuit Breaker 5kV / 1200A & 2000A / 36kA & 50kA PowlVac-ND Vacuum Circuit Breaker Contact Information Powell Electrical Systems, Inc. powellind.com info@powellind.com
More informationB CW POWER RELAY
41-241.31B CW POWER RELAY nected in such a way that current, (I A ), leads voltage, (V BA ), by 150 degrees when the motor is operating at unity power factor. Loss of excitation to the motor causes a large
More information3.1. Power Breakers, Contactors and Fuses. Contents. Series NRX Low Voltage Power Circuit Breakers. Power Circuit Breakers
.1 Series NRX Low Voltage Series NRX Low Voltage Product Description Series NRX is a low voltage power circuit breaker suitable for UL 1558, UL 891, and IEC switchgear and switchboards. The compact size
More informationDETAIL SPECIFICATION SHEET
INCH-POUND MIL-DTL-17361/4B(SH) 19 September 2006 SUPERSEDING MIL-C-17361/4A(SH) 13 March 1995 DETAIL SPECIFICATION SHEET CIRCUIT BREAKERS, AIR, ELECTRIC, INSULATED HOUSING (SHIPBOARD USE) TYPES AQB-A101,
More information2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards
1 General 1.1 Switchboards shall be U.L. listed and labeled. 1.2 Each switchboard shall have its own main disconnecting means unless it is located in the same room as its source of origin. In most cases
More informationGE 8000-Line Motor Control Centers Mains, Feeders, Incoming Lines C-1
GE 8000-Line -1 Mains, coming Lines MAINS GENERAL Main units consist of an externally operable circuit disconnect, either a fusible switch or a circuit breaker. Sizes by ampere rating, short-circuit rating,
More informationXP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System
NEC/ Applications Protection and control of electrical apparatus and circuits in hazardous environments, either indoor or outdoor. Designed for Class I, Division 2 areas where flammable gases or vapors
More informationSECTION MOTOR CONTROLLERS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 29 11 MOTOR CONTROLLERS SPEC WRITER NOTE: Delete between // ---- // if not applicable to project. Also, delete any other item or paragraph not applicable to
More informationBolted contact switches. Pringle switches
Bolted contact switches Pringle switches Eaton s Pringle bolted contact switches History Eaton s PringleT switches have helped pioneer the development of high-quality electrical products for commercial
More informationProtectors. 35mm DIN rail snap-on mounting. Wide range of accessories
Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified
More informationFigure 1. Type CWP-1 Ground Relay (Front View) Figure 2. Type CWP-1 Ground Relay (Rear View) E
Figure 1. Type CWP-1 Ground Relay (Front View) Figure 2. Type CWP-1 Ground Relay (Rear View) 41-242.5E 2 Typical 60 Hertz time product curves for the type CWP-1 relay are shown in Figure 4 with 100 volts
More informationType 2 Arc Resistant WL Low Voltage Metal-Enclosed Switchgear
Type 2 Arc Resistant WL Low Voltage Metal-Enclosed Switchgear IMPORTANT The information contained herein is general in nature and not intended for specific application purposes. It does not relieve the
More informationABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet
ABB Instruction Leaflet 41-137.2E Effective: February 1994 Supersedes I.L. 41-137.2D, Dated February 1973 ( )Denotes Change Since Previous Issue. Type KRV Directional Before putting relays into service,
More informationABB. Type CRQ Directional Negative Sequence Relay for Ground Protection B 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION CAUTION
ABB Instruction Leaflet 41-163.2B Effective: January 1977 Supersedes I.L. 41-137.3A, Dated September 1974 ( ) Denotes Change Since Previous Issue Type CRQ Directional Negative Sequence Relay for Ground
More informationMagnum IEC Air Circuit Breakers and Drawout Cassette Engineering Data
Effective May 2003 Magnum IEC Air Circuit Breakers and Drawout Cassette Engineering Data Magnum IEC Air Circuit Breaker Product Family The New Magnum Narrow Frame Drawout Breaker and Cassette TD030003E
More informationElectromagnetic Industries LLP
GROUND FAULT CURRENT DETECTION GFM Relay (Model 252 & 262) The GFM system is designed for electrical protection, not for personnel protection Application: These Class 1 (Model GFM) Ground Fault protection
More informationPRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA:
Supersedes: 160.55-PW4 (1199) FORM 160.55-PW4 (600) PRODUCT DRAWING YORK INTERNATIONAL CORPORATION P.O. Box 1592, YORK, PA 17405 CONTRACTOR ORDER NO. YORK CONTRACT NO. YORK ORDER NO. WIRING DIAGRAM FIELD
More informationWasher-Extractor. Parts. Cabinet Freestanding. See Page 3 for Model Numbers R001C P/N
P/N 230816 DOOR UNLOCK BUTTON PRESS & HOLD Washer-Extractor Cabinet Freestanding See Page 3 for Model Numbers Parts R001C Part No. F230557R1 April 1999 Table of Contents Title Page Parts Ordering Information...
More informationGE Consumer & Industrial Electrical Distribution. Power Break II. Insulated Case Circuit Breakers
GE Consumer & Industrial Electrical Distribution Power Break II Insulated Case Circuit Breakers Table of Contents Power Break II Circuit Breakers......................... 3 Basic Configuration.......................................
More informationWL Low Voltage Metal-Enclosed Switchgear
www.usa.siemens.com/switchgear WL Low Voltage Metal-Enclosed Switchgear Selection and Application Guide Answers for industry. Table of Contents General Information... 2 Construction Details... 3-5 WL
More informationcontactor may be required to interrupt up to 200% current. The N.O. contacts are equipped with permanent magnet blowouts to meet this requirement.
DP Contactors DC Control DP Definite Purpose Contactors are designed for DC adjustable speed drive circuits using silicon controlled rectifier switching and other controls where a combination of normally
More informationSUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)
SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities
More information