PoweMr' With 18 Mechanism '. 1 . / ,, ( c :11t

Size: px
Start display at page:

Download "PoweMr' With 18 Mechanism '. 1 . / ,, ( c :11t"

Transcription

1 ) rvac Vacuu m Circuit. Breaker PoweMr' With 8 Mechanism L- '.. /,, ( (' p c :t )

2 FRONT VIEW,. 0 3 Fig. Front View of Breaker with Front Cover 3. COUNTER 0. INTERRUPTER ASSEMBLY Fig. 2 Front View of Breaker without Cover RENEWAL MECHANISM ASSEMBLIES CLOSE& CONTINUOUS LATCH QUANTITY BREAKER CURRENT CURRENT CATALOG MODEL PER DESCRIPTION TYPE AMPERES KA NUMBER DESIGNATOR BREAKER Complete VB / , G00-0 (Not Available) ML-8 & G002 - (Not Available) Mechanism G003 - (Not Available) VB / , 78 (Two Trip Coils) VB *Interrupter 750 & / , 58, G004-2 (Not Available) Ass'y not Mechanism G005-2 (Not Available) included cat numbers (Two Trip Coils) *Must spec. are applicable G006-2 (Not Available) Trip, Close to all (Spec. Aux. Sw.) & Motor bur types G007-2 (Not Available) Voltage G008-2 (Not Available) *Standard Note: G007 replaces G00, (Two Trip Coils) Duty G002, G G009-2 (Not Available) GOOS replaces G003, GOOS. (Spec. Aux. Sw.) G009 replaces G G G00 replaces G G G0 replaces GOOS. (Two Trip Coils) G02 replaces G G02-3 (Spec. Aux. Sw.) 2

3 RENEWAL MECHANISM ASSEMBLIES CONTINUOUS CLOSE & QUANTITY BREAKER CURRENT LATCH CATALOG MODEL PER DESCRIPTION TYPE AMPERES CURRENT NUMBER DESIGNATOR BREAKER Complete PVDB- S.S /200 32,40 044DS2G00-0 (Not Available) ML-8 & -2S & 2000 (SN) Mechanism 044DS2G002-0 (Not Available) (3N) interrupter 044DS2G003-0 (Not Available) Ass'y not (2T-Coils & SN) included 044DS2G004 - (Not Available) 0 Must spec. Q44DS2GOOS - (Not Available) Trip, Close Note: 044[ S2G00 replaces (2 T-Coils) - (Not Available) & Motor G00, G002, G004, G006 & GOOS 044DS2G006 - (Not Available) Voltage 044DS2( 0 replaces 044DS2G007 - (Not Available) standard G003, GOOS a (Spec. 24V Trip) Duty 044DS (Not Available) 044DS (Not Available) (Two Trip Coils) Dash pot VB-4.6-2SO 200/2000 SS, DS Ass'y for &350 Extended 044DS200-2 Capacitor VB / , 78 (Two Trip Coils) Switching Breaker Types to Include Duty VB / ,58, 78 Extended Capacitor 750 & 000 Switching Feature AND PVDB-S.S-20 & 2S 600/ 200 & ,40 0,, 2, for PVDB RECOMMENDED RENEWAL PARTS Primary Disconnect A272S0002 VB-0,, 2, 3 6 Contact Assembly 200-SS 0282A270 G A2700G A2700G / A2834G002 VB- 0,, 2, Operating Rod All Ratings - 077C504G00 PVDBO,, Spring-Charging 48V-DC 077CS050G003 VB-0,, 2, 3 Motor 2SV-DC & 20V-AC 077CSOSOG00 PVDB 0,, 2 250V-DC & 240V-AC 077CS050G002 4 Charging Link A'ssy G00 VB-0,, 2, 3 PVDB 0,, 2 s Relay-Anti Pump 48V-DC 0282A2008P00 VB- 0, (Non-Nuclear) 25V-DC 2082A2008P002 &PVDB 0 250V-DC 0282A2008G00 20V-60 Hz 0282A2008P V-60 Hz 0282A2008P004 20V-SOHz 0282A2008P V-50Hz 0282A2008P006 Relay (Anti-Pump) 48V-DC 0282A7350P00 VB2,3 Non-Nuclear 2SV-DC 0282A7350P002 & PVDB, 2 250V-DC 0282A 7350G00 20V-AC 50/00HZ 0282A7350P V-AC 50/00HZ 0282A7350P004 Spec. Form-C Cont. 48V-DC 0282A7350P03 Spec. Form-C Cont. 2SV-DC 0282A7350P04 3

4 OTHER VIEWS. PRIMARY DISCONNECT 20. TRACK ROLLERS 23. SPRING DISCHARGE INTERLOCK 28. SECONDARY CONTROL CARRIAGE Fig. 3 Rear View 2. OPERATING ROD 2. WIPE SPRING ASS'Y. INTERRUPfER CLAMP 30. EROSION DISK Fig. 4 Operating Rod & Wipe Spring RECOMMENDED RENEWAL PARTS 6 Trip Coil (5 cycle) 48VOC G00 V8-0,, 2, 3 *Single & Dual 25 VDC G voe G003 Cap Trip (240 VAC) G004 Trip Coil (3 cycle) 48VOC G008 V8-0,, 2, 3 *Single & Dual 25 VDC G voe G006 Cap Trip ( 240 VAC) G009 Trip Coil (5 cycle) 48VOC G00 PVD8 0,, 2 *Single & Dual 25 voe ( st Coil) G VDC (2nd Coil) G VDC G003 Cap Trip (240 VAC) G004 4 Trip Coil (3 cycle) 48VOC G008 PV08 0,, 2 *Single & Dual 25 voe (st Coil) G VDC (2nd Coil) G VD G006 Cap Trip (240 VAC) G004 st Coil Only Cap Trip (240 VAC) G009 PV08 0,, 2 2nd Coil Only

5 RECOMMENDED RENEWAL PARTS 7 Close Coil 48VDC G00 V8-0,, 2 25 VDC G002 & PVD8 0, 250 VDC G VAC G004 V8-0, (Not Available) & PVD8 0 Note: G006 replaces G004 and G007 replaces G VAC G005 (Not Available) 20 VAC G006 V VAC G007 & PVD8 7 Close Coil 48VDC G00 V VDC G002 & PVD VDC G VAC G VAC G VDC G00 V VDC G002 & PVD VDC G004 8 Control Sw. Normally Open 0282A7094P00 V8- o, 4 52/SMLS & 52/LCS & 52/CLMS & PVD80 Control Sw. Normally Closed 0282A7094P002 52/CHG. Control Sw. Normally Open 0282A7094P00 V8-2, /SMLS & 52/LCS & PVD8, 2 Control Sw. Normally Closed 0282A7094P002 52/CHG. Control Sw. Normally Open 0282A7354P003 52/CLMS 9 Auxiliary Sw. 4-a's & 4-b's P00 V80, S8-2 TYPE 5-a's & 5-b's P00 & PVD8 0 Auxiliary Sw. 4-a's & 4-b's P00 V82,3 Electro Sw. Type 5-a's & 5-b's P00 & PVD8, 2 RENEWAL INTERRUPTER ASSEMBLIES CONTINUOUS CLOSE & LATCH QUANTITY REFERENCE BREAKER CURRENT CURRENT CATALOG MODEL PER NUMBER TYPE AMPERES KA NUMBER DESIGNATOR BREAKER A73 OG00 VB-0,, 2, A275 G A275 G A275 G /2000* A275 G08 200/2000* A275 G A275 G A275 G /2000* A275 G A275 G A275 G A275 G A275 G /2000* A275 G /2000* A275G A275 GOOS A275 G006 5

6 RENEWAL INTERRUPTER ASSEMBLIES CONTINUOUS CLOSE & LATCH REFERENCE BREAKER CURRENT CURRENT NUMBER TYPE AMPERES KA CATALOG NUMBER MODEL DESIGNATOR QUANTITY PER BREAKER /2000* /2000* /2000* OTHER VIEWS A275G054 VB-0,, 2, A275G A275 G A275 G A275 G A275 GOOS 0282A275 G A275 G A275 G A275 G A275G A275 G A6524G004 PVDB 0,, A6524G A6524G A6524G SPRING CHARGING MOTOR& CHARGING ASS'Y 4. CHARGING LINK ASS'Y 6. TRIPCOIL 7. CLOSE COIL 9. AUXIlJARY SWITCH 4. TRIP LATCH (HIDDEN FROM VIEW) 5. CLOSE LATCH 6. CHARGING RATCHET 7. CLOSING SPRING & GUIDE A'SSY 8. OPENING SPRING 9. CASTER WHEEL &BRACKET 2. POSITTVE INTERLOCK 22. NEGATIVE INTERLOCK 25. CLOSE SHAFT 27. OPENING SPRJNGROD 29. GROUND BUS 3. V AC. RUPT. STOP FOR CENTER PHASE 33. CLOSE LATCH PIN 34. PROP LATCH 35. CLOSE SPRING CRANK 6 IS FIG.5 Bottom View

7 ADDITIONAL RENEWAL PARTS VB-0,, 2, 3 Interrupter Clamp 0282A506 G003 & PVDB 0,, 2 3 VB-0,, 2, 3 2 Wipe Spring Assembly G002 & PVDB o,, Operation Counter 0282A768P00 VB- 0, l, 2, 3 Spring for Counter 0282A738P00 & PVDB 0,, 2 VB- 0,, 2, 3 4 Trip Latch 0282A747P00 & PVDB 0,, 2 5 Close Latch 0282A7244G00 "# VB-0, "#See Reference #33 (Not Available) & PVDB O Close Latch Pin for replacement P00 VB- 2 (Not Available) & PVDB Note: P P003 VB-3 replaces G00 & P00 & PVDB 2 VB-0,, 2, 3 6 Charging Ratchet G00 & PVDB 0,, A73 G00 VB-0,, 2, 3 7 Closing Spring & Guide Ass'y 0282A73G002 PVDB 0,, 2 VB- 0,, 2, 3 8 Opening Spring 0282A7043P00 & PVDB 0,, Caster Wheel & Bracket 0282B8085GOO VB-0,, 2, 3 20 Truck Rollers 0282A2464G00 VB- 0,, 2, Positive Interlock GOO VB-0,, 2, 3 22 Negative Interlock 077C5007G002 VB-0,, 2, 3 OTHER VIEWS TOGGLE LINKAGE ASS'Y 5. RELAY 26. CLOSE CAM 8. CONTROLSWITCH Fig. 6 Bottom View Fig. 7 Bottom View 7

8 ADDITIONAL RENEWAL PARTS REFERENCE CATALOG NUMBER DESCRIPTION NUMBER 23 Spring Discharge Interlock G00 24 Toggle Linkage Ass'y G00 Note: G002 (Not Available) Replaces G G Close Shaft P00 Note: 0209B P00 (Not Available) Replaces 0209B8009P P00 - See note bottom page 8 26 Close Cam 044D 229P00 27 Opening Spring Rod 0282A728G00 28 Secondary Disconnect ASM G00 *Male Pins 0282A208P00 29 Ground Bus Bar 0282A247P00 30 Erosion Disk 0282A796G00 Indicator for Erosion Disk 0282A795P00 3 Stop for Center Phase 0282A743G00 Vacuum Interrupter (Not Available) Note: 077C6640G00 replaces 077C6640G A743G00 33 Close Latch Pin 0209B3894P00 Note: To replace Close Latch #0282A7244G00 Order B8075P003 and B3894P00 34 Prop Latch 0282A 765G00 - See note bottom page 8 (Not Available) Note: 0282A7327G A7327G00 Replaces 0282A765G00 35 Close Spring Crank P00 - See note bottom page 8 (Not Available) Note: 0209B8000P B8000P002 Replaces P00 MODEL DESIGNATOR VB-0,, 2, 3 V8-0, & PVD8 O VB- 2, 3 & PVD8, 2 VB- 0, & PVDB 0 VB- 2, 3 & PVDB, 2 V8-0,, 2, 3 & PVDB 0,, 2 V8-0,, 2, 3 & PVD8 0,, 2 V8-0,, 2, 3 VB-0,, 2, 3 V8-0,, 2, 3 &PVD8 0,, 2 V8- O V8-, 2, 3 & PVD8, 2 VB 2, 3 & PVDB, 2 V8- o, & PVD8 O VB- 2, 3 & PVDB, 2 VB-0, & PVDB o VB- 2, 3 &PVDB,2 QUANTITY PER BREAKER NOTE: REFERENCE PART NUMBERS 25, 34 & 35 MUST BE REPLACED AS SET FOR VB- 0, & PVDB 0 MODELS I./ 8

9 OTHER VIEWS! NEGATIVE INTERLOCK Fig. 8 Front and Side View STATIONARY AUX SW. Fig. 9 PVDB Mechanism Compartment View RECOMMENDED ITEMS FOR PVDB No Ref. Roof Bushing Ass'y C6626G00 PVDBO,, 2 6 Number C6628G00 32 Stationary Aux. Sw. Mounting 044D56G00 PVDBO (Not Available) Aux. Sw. (SB-2 Type) *3-a's & 3-b's 0226A9287G0 O PVDBO As Required "6-a's & 6-b's 0226A9287G0 *0-a's & 0-b's 0226A9287G02 Stationary Aux. Sw. Mounting *Single (3 or 6-a's & 3 or 6-b's) 044D56G002 PVDB, 2 *Tandem (0-a's & 0-b's) G003 Aux. Sw. (Electro Sw. Type) *3-a's & 3-b's P00 PVDB,2 As Required "6-a's & 6-b's P00 "0-a's & 0-b's G00 Note: 044D56G002 or G003 Replaces G00. With this replacement New Electro Sw. Types must also be ordered. No Ref. Number External Trip Ass'y Parts 2082A6557GOO PVDBO, 2 No Ref. Compartment Heater Mounting Number 2 Heaters 0282A659GOO PVDB 0, 2 4 Heaters 0282A659G002 Strip Heater 300W/240V 0282A4386POO PVDB 0, 2 As required No Ref. Number Door Latch Parts 0282A6557G002 PVDB 0, 2 2 No Ref. Number Bushing Grounding Spring 200A 0282A6496GOO PVDBO, A 0282A6496G002 9

10 RECOMMENDED ITEMS FOR MAINTENANCE Figure #0 Lifting Bracket 0209B6588GOO VB-0,, 2. 3 No Ref. VB-0,, 2, 3 Number Travel Recorder Parts G00 &PVDB0,,2 No Ref. VB-0,, 2, 3 Number Manual Charge Handle 2082A7227P00 & PVDB 0,, 2 No Ref. Closing Spring Gag Plate G00 VB-0,, 2, 3 Number G002 PVDB 0,, 2 No Ref. Test Coupler 077C3943G00 VB- 0,, 2, 3 Number Outline & Application Instructions 077C3944 No Ref. Mechanism Removal Bracket G00 PVDBO Number No Ref. Fastener Assortment ("X" washer) 0282A205G00 VB-0,, 2, 3 Number &PVDB0,,2 No Ref. Spring Assortment 0282A6558GOO VB-0,, 2, 3 Number &PVDB0,,2 No Ref. Lubricating Grease 0282A2048P02 VB-0,, 2, 3 Number & PVDBO,, 2 ) No Ref. Pin Retainer Assortment 0282A5293G00 VB-0,, 2, 3 Number (Snap & "C" Rings) & PVDB 0,, 2 '. j 0

GE CONSUMER & INDUSTRIAL

GE CONSUMER & INDUSTRIAL GE CONSUMER & INDUSTRIAL GE POWER/VAC Vacuum Circuit Breaker Type PVDB1 15.5 kv ML18/ML18H Spring Operating Mechanism Instruction Number GEK-90211C Table of Contents Section 1. Introduction 1-1 Safety...

More information

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut Page 1 Supersedes Renewal Parts Data 33-790-1G pages 1-20 dated December, 1988 Mailed to: C, D, E/33-700 Westinghouse DS and DSL Low Voltage Power Circuit Breakers and Cell Parts Contents Pages DS Breaker

More information

Vacuum Circuit Breaker Type VAD-3

Vacuum Circuit Breaker Type VAD-3 Instruction Bulletin Bulletin 6055-11 Vacuum Circuit Breaker Type VAD-3 4.76 kv, 29 ka (250 MVA) 4.76 kv, 41 ka (350 MVA) 8.25 kv, 33 ka (500 MVA) 15.0 kv, 18 ka (500 MVA) 15.0 kv, 28 ka (750 MVA) 15,0

More information

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy. Type SDV6 distribution circuit breaker Top performance - proven reliability Answers for energy. Table of contents Introduction 2-4 Type 3AH3 stored-energy operating mechanism 6 Vacuum interrupters 7 Ratings

More information

Instruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035

Instruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035 Instruction Bulletin 4402-997-0 February 999 Middletown, OH, USA DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 605 DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker

More information

A Summary of Major Improvements to the ABB Recloser and Type R Breaker

A Summary of Major Improvements to the ABB Recloser and Type R Breaker A Summary of Major Improvements to the ABB Recloser and Type R Breaker Table of Contents Introduction....................................................................3 Center Bumper..................................................................4

More information

Frame Sizes: AKJ/ AKJT I AKJU-50 and AKR/ AKRU-30/ 50, AKRT-50

Frame Sizes: AKJ/ AKJT I AKJU-50 and AKR/ AKRU-30/ 50, AKRT-50 RENEWAL PARTS LOW VOLTAGE POWER CIRCUIT BREAKERS Frame Sizes: AKJ/ AKJT I AKJU-50 and AKR/ AKRU-30/ 50, AKRT-50 GEF-4527F Supersedes GEF-4527E TABLE A. INDEX OF BREAKER MODELS COVERED BY THIS PUBLICATION

More information

Horizontal Circuit Switchers

Horizontal Circuit Switchers > Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving

More information

www. ElectricalPartManuals. com BBC Brown Boveri Electric Renewal Parts 1-T -E Low-Voltage Power Circuit Breakers

www. ElectricalPartManuals. com BBC Brown Boveri Electric Renewal Parts 1-T -E Low-Voltage Power Circuit Breakers i BBC BROWN BOVERI Type LK and LKE 800 thru 4200 Amperes Type LKD 800 and 1600 Amperes 600 Volts RP 6118A Renewal Parts 1-T -E Low-Voltage Power Circuit Breakers Brown Boveri Electric RP 6118-1A Page 2

More information

www. ElectricalPartManuals. com Type AM Magne-Biast Circuit Breakers RENEWAL PARTS

www. ElectricalPartManuals. com Type AM Magne-Biast Circuit Breakers RENEWAL PARTS RENEWAL PARTS Ordering Instructions 1. Always specify the complete nameplate data of the breaker. 2. Specify the quantity, catalog number (if listed), reference number (if listed) description, and this

More information

S&C Type FVR Substation Circuit Breaker

S&C Type FVR Substation Circuit Breaker S&C Type FVR Substation Circuit Breaker 15 kv to 38 kv, 200 kv BIL, 1200 A, Class 6065 Instructions for Installation 60553014 S&C ELECTRIC COMPANY Specialists in Electric Power Switching and Protection

More information

Horizontal Circuit Switchers

Horizontal Circuit Switchers > Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving

More information

DEF 005. WavePro Power Circuit Breakers A Frames, Vac. Renewal Parts

DEF 005. WavePro Power Circuit Breakers A Frames, Vac. Renewal Parts g DEF 005 WavePro Power Circuit Breakers 3200 5000 A Frames, 240 600 Vac Introduction This guide contains a listing of the parts and assemblies that are available as replacement parts for WavePro 3200

More information

DS/DSII Low Voltage Switchgear. Renewal Parts. Cutler-Hammer. Renewal Parts. Effective: October Page 1

DS/DSII Low Voltage Switchgear. Renewal Parts. Cutler-Hammer. Renewal Parts. Effective: October Page 1 New Information Supersedes Data 33-790-1H, dated October 1996 DS/DSII Low Voltage Switchgear Page 1 DS Switchgear Assembly DSII Switchgear Assembly Contents Pages DS Switchgear (Front View) 2 DSII Switchgear

More information

GEF Renewal Pans. low Vohage Power Circuit Breakers. Type AKR-30S and AKRU-30S. www. ElectricalPartManuals. com

GEF Renewal Pans. low Vohage Power Circuit Breakers. Type AKR-30S and AKRU-30S. www. ElectricalPartManuals. com -- GEF-6005 Renewal Pans low Vohage Power Circuit Breakers Type AKR-30S and AKRU-30S INTRODUCTION This manual provides a listing of the parts and assemblies that are availle as replacement parts for low

More information

GENERAL fj ELECTRIC INSTRUCTIONS AND RECOMMENDED PARTS FOR MAINTENANCE POWERNAC* VACUUM CIRCUIT BREAKER WITH ML-17 MECHANISM.

GENERAL fj ELECTRIC INSTRUCTIONS AND RECOMMENDED PARTS FOR MAINTENANCE POWERNAC* VACUUM CIRCUIT BREAKER WITH ML-17 MECHANISM. INSTRUCTIONS AND RECOMMENDED PARTS FOR MAINTENANCE GEK-90208 Types: o POWERNAC* VACUUM CIRCUIT BREAKER WITH ML-17 MECHANISM VB-4.16-250-000A-78-0, -1, -2, - VB-4.16-50-1200A-78-0, -1, -2, - VB-4.16-50-2000A-78-0,

More information

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV) SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities

More information

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (38KV) SUBSTATION VACUUM CIRCUIT BREAKER (38KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities

More information

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV) SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products

More information

www. ElectricalPartManuals. com Cutler-Hammer Power Breaker Center Renewal Parts for Low Voltage Power Circuit Breakers Types DB, DBL and DBF

www. ElectricalPartManuals. com Cutler-Hammer Power Breaker Center Renewal Parts for Low Voltage Power Circuit Breakers Types DB, DBL and DBF New Information Control Relay Auxiliary Switch Operating Mechanism CutlerHammer Power Center 10 Maxwell Avenue Greenwood, SC 29646 1877276979 Closing Solenoid 2254 Renewal Parts for Low Voltage Power Circuit

More information

RENEWAL PARTS AK-2-15 AK-2-25 AK-3-25 AKF-2-25 AK-2A-15 AK-2A-25 AK-3A-25 AKF-2A-25 AKU-2-25 AKU-3-25 AKU-2A-25 AKU-3A-25

RENEWAL PARTS AK-2-15 AK-2-25 AK-3-25 AKF-2-25 AK-2A-15 AK-2A-25 AK-3A-25 AKF-2A-25 AKU-2-25 AKU-3-25 AKU-2A-25 AKU-3A-25 Data ubject to change without notice. RENEWAL PARTS POWER CIRCUIT BREAKERS TYPES 225 AMP FRAME SIZE 00 AMP FRAME SIZE GEF-449G Supersedes GEF-449F AK-2-5 AK-2-25 AK-3-25 AKF-2-25 AK-2A-5 AK-2A-25 AK-3A-25

More information

Parts Manual. Transfer Switch. OTPCB (Spec A) 150/225/260 Amps. English Original Instructions (Issue 4)

Parts Manual. Transfer Switch. OTPCB (Spec A) 150/225/260 Amps. English Original Instructions (Issue 4) Parts Manual Transfer Switch 50/225/260 Amps OTPCB (Spec A) English Original Instructions -203 962 0228 (Issue ) This catalog covers models produced under the Cummins /Onan and Cummins Power Generation

More information

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION Medium Voltage Standby non-paralleling Control 1. GENERAL GUIDE FORM SPECIFICATION A. The requirements of the contract, Division 1, and part 16 apply to work in this section. 1.01 SECTIONS INCLUDE A. Medium

More information

Submersible Vacuum Fault Interrupters

Submersible Vacuum Fault Interrupters Submersible Vacuum Fault Interrupters UG Distribution Medium Voltage Vacuum Fault Interrupters Functional Specification Guide PS024002EN Functional Specification for 2.4kV to 17.5kV UG Distribution Medium

More information

BBC. Renewal Parts. I-T-E Low-Voltage Power Circuit Breakers

BBC. Renewal Parts. I-T-E Low-Voltage Power Circuit Breakers BBC BROWN BOVERI RP 6..2.8-2C Renewal Parts I-T-E Low-Voltage Power Circuit Breakers Type K-000, 4000, 0008, and 40008 Stationary and Drawout Mounted 000 and 4000 Amperes 600 Volts RP 6..2.8-2 Page 2 Table

More information

www. ElectricalPartManuals. com POWER CIRCUIT BREAKERS TYPES AK-2/3/2A/3A-50, AKU-2/3/2A/3A-50, AKT-2/3/2A/3A-50 GENERAL fj ELECTRIC

www. ElectricalPartManuals. com POWER CIRCUIT BREAKERS TYPES AK-2/3/2A/3A-50, AKU-2/3/2A/3A-50, AKT-2/3/2A/3A-50 GENERAL fj ELECTRIC ORDERNG NSTRUCTONS. Always specify complete nameplate data of the breaker. 2. Specify the quantity, catalog number (if listed), reference number (if listed), description, and this bulletin number. 3. Standard

More information

Using new Magnetically Actuated Vacuum Interrupter technology for safe and reliable medium voltage circuit breaker switching in mines

Using new Magnetically Actuated Vacuum Interrupter technology for safe and reliable medium voltage circuit breaker switching in mines Using new Magnetically Actuated Vacuum Interrupter technology for safe and reliable medium voltage circuit breaker switching in mines Abstract: The development of the magnetically actuated vacuum interrupter

More information

Type SDV7 distribution circuit breaker family

Type SDV7 distribution circuit breaker family www.usa.siemens.com/sdv7 Type SDV7 distribution circuit breaker family 5.5 kv to 8.0 kv Answers for infrastructure. Table of contents Introduction 0 Vacuum interrupters 0 Simple current path 05 Low-maintenance

More information

VacClad-W type VCP-W 5 and 15 kv, 36-inch-wide switchgear components

VacClad-W type VCP-W 5 and 15 kv, 36-inch-wide switchgear components Supersedes July 2002 Contents Page Procedure for identifying parts... 2 Customer ordering instructions.... 2 Distributor ordering instructions.... 2 Front panel components.... 3 Breaker pan assembly....

More information

SF 6 gas insulated RMU SafePlus 24 kv. ABB SafePlus 24 kv SF6 gas insulated RMU 1

SF 6 gas insulated RMU SafePlus 24 kv. ABB SafePlus 24 kv SF6 gas insulated RMU 1 SF 6 gas insulated RMU SafePlus 24 kv 25.03.2010 SafePlus 24 kv SF6 gas insulated RMU 1 Secondary distribution 400 kv Transmission substation Transformer 40-70 kv 130 kv Main Substation Secondary distribution

More information

Descriptive Bulletin. R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

Descriptive Bulletin. R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv Descriptive Bulletin R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv Introduction The R-MAG TM is truly the next generation in medium voltage vacuum circuit breaker

More information

RENEWAL PARTS I C302AA A-2 300V AB A-4800V A C A -SOOOV PARTS RECOMMENDED FOR NORMAL STOCK

RENEWAL PARTS I C302AA A-2 300V AB A-4800V A C A -SOOOV PARTS RECOMMENDED FOR NORMAL STOCK NGrE: RENEWAL PARTS IC0A HIGH VOLTAGE CONTACTORS I C0AA 00A 00V AB00A800V A C 00A SOOOV PARTS RECOMMENDED FOR NORMAL STOCK The current is identified by the number following the voltage letter in the IC

More information

Air-insulated switchgear UniGear type ZS1

Air-insulated switchgear UniGear type ZS1 Air-insulated switchgear UniGear type ZS1 ABB Power Technologies / 1-7074 D 12-03-2003 - Air-insulated switchgear UniGear type ZS1 ABB Power Technologies / 2-7075 D 1 2-03-2003 - Rated voltage kv 12 17.5

More information

MASTERCLAD. Metalclad Indoor Switchgear 27 kv with Type VR Vacuum Circuit Breakers Class Instruction Bulletin. Retain for future use.

MASTERCLAD. Metalclad Indoor Switchgear 27 kv with Type VR Vacuum Circuit Breakers Class Instruction Bulletin. Retain for future use. Instruction Bulletin Retain for future use. MASTERCLAD Metalclad Indoor Switchgear 27 kv with Type VR Vacuum Circuit Breakers Class 6055 HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully

More information

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism R-MAG Features: Low maintenance 10,000 mechanical operations (five times ANSI requirements) Simple magnetic actuator Vacuum interruption Definite

More information

Descriptive Bulletin. R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

Descriptive Bulletin. R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv Descriptive Bulletin R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv Introduction The R-MAG is truly the next generation in medium voltage vacuum circuit breaker technology.

More information

Selection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker

Selection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker Selection and Application Guide Supplement WL UL1066 4-Pole Circuit Breakers usa.siemens.com/wlbreaker WL Power Circuit Breaker Table of Contents Ratings for UL 1066 (ANSI C37) Circuit Breakers Frame size

More information

1VAL2401-SG Rev D. Spare parts list for Outdoor Products Reclosers, breakers, & padmount switches

1VAL2401-SG Rev D. Spare parts list for Outdoor Products Reclosers, breakers, & padmount switches 1VAL2401-SG Rev D Spare parts list for Outdoor Products Reclosers, breakers, & padmount switches Reclosers GridShield recloser 12A00736H05 Actuator assist capacitor Single-phase upgrade 15 KV, 800 A, 12.5

More information

Parts Manual. Transfer Switch. OTPCC (Spec A) 300/400/600 Amps. English Original Instructions (Issue 4)

Parts Manual. Transfer Switch. OTPCC (Spec A) 300/400/600 Amps. English Original Instructions (Issue 4) Parts Manual Transfer Switch 00/00/600 Amps OTPCC (Spec A) English Original Instructions -20 962 0229 (Issue ) This catalog covers models produced under the Cummins /Onan and Cummins Power Generation brand

More information

ABB ADVAC TM. INSTALLATION/MAINTENANCE INSTRUCTIONS Medium Voltage Vacuum Power Circuit Breakers and Auxiliary Devices

ABB ADVAC TM. INSTALLATION/MAINTENANCE INSTRUCTIONS Medium Voltage Vacuum Power Circuit Breakers and Auxiliary Devices IB 6.2.13.7-1 1 Rev. 4, June 2000 ADVAC TM INSTALLATION/MAINTENANCE INSTRUCTIONS Medium Voltage Vacuum Power Circuit Breakers and Auxiliary Devices Power T&D Company, Inc. Distribution Systems Division

More information

Medium Voltage Equipment 5-15 kv GM-SG and 38 kv GM38 Metal-Clad Switchgear General

Medium Voltage Equipment 5-15 kv GM-SG and 38 kv GM38 Metal-Clad Switchgear General 13 SWITCHGEAR Medium Voltage Equipment -1 kv GM-SG and 38 kv GM38 Metal-Clad Switchgear General Overview Features Siemens, 7, 1 and 38kV class medium voltage, one- or two-high vacuum circuit breaker switchgear

More information

SDV7. Outdoor distribution circuit breaker family 15.5 kv to 38.0 kv. usa.siemens.com/sdv7

SDV7. Outdoor distribution circuit breaker family 15.5 kv to 38.0 kv. usa.siemens.com/sdv7 0 000 0000000 0000 000000 0000 000 0000000 0000 000000 0000 000 0000000 SDV7 Outdoor distribution circuit breaker family 5.5 kv to 8.0 kv usa.siemens.com/sdv7 SDV7 Brochure Brochure SDV7 The type SDV7

More information

Instructions for VCP-W Simple Electrical Ground & Test Device (SEG&TD) with simplified interlock scheme - bottom terminal set version

Instructions for VCP-W Simple Electrical Ground & Test Device (SEG&TD) with simplified interlock scheme - bottom terminal set version IB131018EN Instructions for VCP-W Simple Electrical Ground & Test Device (SEG&TD) with simplified interlock scheme - bottom terminal set version Contents Description Page 1. Introduction...2 2. Description...2

More information

ADVAC TM Model 03 Medium Voltage Vacuum Power Circuit Breakers and Auxiliary

ADVAC TM Model 03 Medium Voltage Vacuum Power Circuit Breakers and Auxiliary 1 ABB IB 6.2.15.7-1C ADVAC TM Model 03 Medium Voltage Vacuum Power Circuit Breakers and Auxiliary Installation/Maintenance Instructions IB 6.2.15.7-1C November 2005 ABB IB 6.2.15.7-1C 2 TABLE OF CONTENTS

More information

T- VACR Fixed (up to 40kA) T-VAC Draw out (up to 40kA)

T- VACR Fixed (up to 40kA) T-VAC Draw out (up to 40kA) Instructions for the Use, Operation and Maintenance of Types T-VAC and T-VACR Vacuum Circuit Breakers Effective November 2017 T- VACR Fixed (up to 25kA) T-VAC Draw out (up to 25kA) T- VACR Fixed (up to

More information

contactor may be required to interrupt up to 200% current. The N.O. contacts are equipped with permanent magnet blowouts to meet this requirement.

contactor may be required to interrupt up to 200% current. The N.O. contacts are equipped with permanent magnet blowouts to meet this requirement. DP Contactors DC Control DP Definite Purpose Contactors are designed for DC adjustable speed drive circuits using silicon controlled rectifier switching and other controls where a combination of normally

More information

Type SDV7 distribution circuit breaker family Answers for energy.

Type SDV7 distribution circuit breaker family Answers for energy. www.usa.siemens.com/energy Type SDV7 distribution circuit breaker family Answers for energy. Table of contents Table of contents Page Introduction Vacuum interrupters Simple current path Low maintenance

More information

Section 18. Medium Voltage Equipment. BuyLog Catalog 18-1

Section 18. Medium Voltage Equipment.  BuyLog Catalog 18-1 MV One Line...18-2 Motor Control Medium Voltage (Limitamp ) Introduction, Features, Types, Options, References...18-3 Specifications, Ratings, Equipment Reference Publications...18-4 Product Scope...18-5

More information

GE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc

GE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc GE Industrial Solutions User/Installation Manual for 4.76kV -15kV SecoBloc Index General Scope...3 Standards...3 Operating conditions...3 Technical specification...3 Basic structure Features...4 Operation...4

More information

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A - 3700 A R-MAG The R-MAG is truly the next generation in vacuum circuit breakers, combining industry recognized magnetic

More information

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG Medium-Voltage Equipment Selection and Ordering Data Catalog HG 11.0 008 Answers for energy. R-HG11-17.tif Siemens HG 11.0 008 Contents Contents Page SION Vacuum Circuit-Breakers Description General Construction

More information

PowlVac Type PV STD/CDR Vacuum Circuit Breaker

PowlVac Type PV STD/CDR Vacuum Circuit Breaker Instructions PowlVac Type PV STD/CDR Vacuum Circuit Breaker Installation Maintenance Renewal Parts POWELL ELECTRICAL MANUFACTURING COMPANY 8550 MOSLEY DRIVE HOUSTON, TEXAS 77075 USA PHONE (713) 944-6900

More information

Powered by Safety 01.4IB.77000B PowlVac-ND Vacuum Circuit Breaker

Powered by Safety 01.4IB.77000B PowlVac-ND Vacuum Circuit Breaker Powered by Safety PowlVac-ND Vacuum Circuit Breaker 5kV / 1200A & 2000A / 36kA & 50kA PowlVac-ND Vacuum Circuit Breaker Contact Information Powell Electrical Systems, Inc. powellind.com info@powellind.com

More information

Description Notes. 1. Parts are identified by Breaker Type in the top row and Part Description in the left column.

Description Notes. 1. Parts are identified by Breaker Type in the top row and Part Description in the left column. Parts dentification Description Notes Table of Contents Page This Price List contains descriptions and style numbers for VCP-W breakers including 5, 7.5, 15, and 27 kv VCP-W, VCPW-ND, VCPW-SE, and the

More information

AM4.16/7.2/13.8-VR + VR-Series + Replacement Circuit Breaker

AM4.16/7.2/13.8-VR + VR-Series + Replacement Circuit Breaker Instruction Book IB182921EN Supersedes May 2017 Effective August 2018 AM4.16/7.2/13.8-VR + AM4.16-VR + 250 1200A Shown DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY The information, recommendations,

More information

SWITCHGEAR DIVISION PRODUCT PROFILES

SWITCHGEAR DIVISION PRODUCT PROFILES SWITCHGEAR DIVISION PRODUCT PROFILES Metal-Enclosed Load-Interrupter Switchgear Product Profiles Three-Phase, Group-Operated Load-Interrupter Switches with Fuses in Single and Multi-Bay Assemblies Manual,

More information

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG Medium-Voltage Equipment Selection and Ordering Data Catalog HG 11.02 2011 Answers for energy. R-HG11-172.tif 2 Siemens HG 11.02 2011 Contents SION Vacuum Circuit-Breakers Medium-Voltage Equipment Catalog

More information

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents January 2003 Vol. 1, Ref. No. [1011] -1 Medium Voltage Metal-Enclosed Switches Contents Description Page MVS................................... -2 and Breaker MSB........................ -3 Metal-Enclosed

More information

DDBB362 : DRAWER [1/10]

DDBB362 : DRAWER [1/10] DDBB362 : 001 - DRAWER [1/10] Page 1 of 21 DDBB362 : 001 - DRAWER [1/10] 1 2 3 4 5 6 7 M0220957 G5096495 D7813004 12505401 G50911858 10526701 12043006 12043004 G50911810 G50911809 M0226233 M0211018 12493901

More information

MINIATURE CIRCUIT BREAKER

MINIATURE CIRCUIT BREAKER Technical Article MINIATURE CIRCUIT BREAKER T 146 PURCHASE he Spaceage MCB protects wires and cables automatically against overload and short-circuits in domestic, commercial and industrial installations.

More information

Dead Tank Outdoor Vacuum Circuit Breaker, Type VOX

Dead Tank Outdoor Vacuum Circuit Breaker, Type VOX Dead Tank Outdoor Vacuum Circuit Breaker, Type VOX Class 6065 Instruction Bulletin 6065-13 11/2011 Retain for future use. Hazard Categories and Special Symbols Read these instructions carefully and look

More information

3.1. Power Breakers, Contactors and Fuses. Contents. Series NRX Low Voltage Power Circuit Breakers. Power Circuit Breakers

3.1. Power Breakers, Contactors and Fuses. Contents. Series NRX Low Voltage Power Circuit Breakers. Power Circuit Breakers .1 Series NRX Low Voltage Series NRX Low Voltage Product Description Series NRX is a low voltage power circuit breaker suitable for UL 1558, UL 891, and IEC switchgear and switchboards. The compact size

More information

Illustrated Parts List

Illustrated Parts List Illustrated Parts List. Ordering Parts For your convenience, replacement parts and accessories can be ordered from ARPAC by fax 24 hours a day. Please have the following information available to ensure

More information

www. ElectricalPartManuals. com Type AM ,-6 Magne-Biast Circuit Breakers RENEWAL PARTS GENERAL. ELECTRIC GEF-4438A Supersedes GEF-4438

www. ElectricalPartManuals. com Type AM ,-6 Magne-Biast Circuit Breakers RENEWAL PARTS GENERAL. ELECTRIC GEF-4438A Supersedes GEF-4438 Ordering Instructions RENEWAL PARTS 1. Always specify the complete nameplate data of the relay, including complete model of relay. 2. Specify the quantity, catalog number (if listed), reference number

More information

Advance design OEM L-Frames, cell kits, & enclosures Metal-clad switchgear components OEM catalog & pricing

Advance design OEM L-Frames, cell kits, & enclosures Metal-clad switchgear components OEM catalog & pricing Advance design OEM L-Frames, cell kits, & enclosures Metal-clad switchgear components OEM catalog & pricing Introduction A modular system of switchgear building blocks and cassettes provide untouchable

More information

R-MAG Medium Voltage Outdoor Dead Tank Vacuum Magnetic Circuit Breaker

R-MAG Medium Voltage Outdoor Dead Tank Vacuum Magnetic Circuit Breaker 1VAL255101-MB Rev G (replaces IB 38-929M-15A) R-MAG Medium Voltage Outdoor Dead Tank Vacuum Magnetic Circuit Breaker Instruction Manual 15.5 kv 1250/2000/3000/3700 A 27 kv 1250/2000 A Table of Contents

More information

Installation Sheet January, 2016 Supersedes February, 2013

Installation Sheet January, 2016 Supersedes February, 2013 s Installation Sheet January, 016 Supersedes February, 013 E87010-A0104-T003-A6-CLM0 Lighting and Heating Contactor 30 Amp, 3, 4, 5 Pole Magnetically Latched Description Magnetically latched CLM lighting

More information

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position LET S BE PACIFIC November 0 Volume Number 5 ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position Federal Pacific has the capability to engineer, fabricate and assemble

More information

FEEDMAX W/ SHUTTLE IJ SERIES. Parts Manual

FEEDMAX W/ SHUTTLE IJ SERIES. Parts Manual FEEDMAX W/ SHUTTLE IJ SERIES Parts Manual TABLE OF CONTENTS FEEDMAX SYSTEM FEEDMAX CONVEYOR (FIG. 1)....3 FRAME ASSEMBLY (FIG. 2).. 5 ADJUSTABLE PULLEY ASSEMBLY (FIG. 3)..7 DRIVE ASSEMBLY (FIG. 4)....9

More information

SECTION 3. PARTS INFORMATION

SECTION 3. PARTS INFORMATION /592 SECTION 3. PARTS INFORMATION 3-1. INTRODUCTION This section lists the replaceable parts of the Henny Penny Model 590 fryer. 3-2. GENUINE PARTS Use only genuine Henny Penny parts in your fryer. Using

More information

PATENT PENDING. Phone: (877) Operation and Service Manual

PATENT PENDING.   Phone: (877) Operation and Service Manual PATENT PENDING Phone: (877) 544-2291 Operation and Service Manual 2 IMPORTANT NOTICE This document contains information intended to aid in the proper installation, operation, and maintenance of the product

More information

CD5--- CA4--- CD6---- CB2---- CB4---- PARTS RECOMMENDED FOR NORMAL STOCK

CD5--- CA4--- CD6---- CB2---- CB4---- PARTS RECOMMENDED FOR NORMAL STOCK RENEWAL PARTS CA2--- CD5--- CA4--- CD6---- CB2---- CB4---- ' PARTS RECOMMENDED FOR NORMAL STOCK NOTE: The current is identified by the number following the voltage letter in the IC designation. EXAMPLE:

More information

ON LOAD GEARS OPERATIONAL AND MAINTENANCE MANUAL VACUUM CIRCUIT BREAKER TYPE VS36

ON LOAD GEARS OPERATIONAL AND MAINTENANCE MANUAL VACUUM CIRCUIT BREAKER TYPE VS36 ON LOAD GEARS OPERATIONAL AND MAINTENANCE MANUAL VACUUM CIRCUIT BREAKER TYPE VS36 We thank you for having purchased VCB s from us. We are sure you will be very happy with the performance and service of

More information

Certi cation Record INDUSTRIAL CONTROL EQUIPMENT Motor Controllers Magnetic

Certi cation Record INDUSTRIAL CONTROL EQUIPMENT Motor Controllers Magnetic Certi cation Record Customer Schneider Electric USA, Inc. Square D Raleigh (Knightdale) Plant, 8001 Knightdale Blvd Knightdale NC USA 27545 Class 3211 04 INDUSTRIAL CONTROL EQUIPMENT Motor Controllers

More information

MODEL EVA PARTS MANUAL Rev.1.03

MODEL EVA PARTS MANUAL Rev.1.03 MODEL EVA PARTS MANUAL Rev.1.03 CMA DISHMACHINES 12700 KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841 800-854-6417 FAX 714-895-2141 www.cmadishmachines.com TABLE OF CONTENTS MODEL EVA 1. PARTS MANUAL...3

More information

Illustrated Parts List

Illustrated Parts List Illustrated Parts List. Ordering Parts For your convenience, replacement parts and accessories can be ordered from ARPAC by fax 24 hours a day. Please have the following information available to ensure

More information

www. ElectricalPartManuals. com INSTRUCTIONS "INERTEEN AND OIL INSULATED FEEDER SWITCHES DESCRIPTION INSTALLATION MAINTENANCE

www. ElectricalPartManuals. com INSTRUCTIONS INERTEEN AND OIL INSULATED FEEDER SWITCHES DESCRIPTION INSTALLATION MAINTENANCE r \ FIG. 1. Cutaway View of Typical Switch. I.L. 46-723-1 DESCRIPTION INSTALLATION MAINTENANCE INSTRUCTIONS THE INERTEEN AND OIL INSULATED FEEDER SWITCH provides complete switching facilities in a minimum

More information

Specification Guide. for RMVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

Specification Guide. for RMVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers Specification Guide for RMVAC Direct Replacement AC Medium Voltage Circuit Breakers Table of Contents 1.0 General Work Scope... 3 2.0 Standards... 3 3.0 Supplier Qualifications... 4 4.0 Circuit Breaker

More information

Convertamatic 265LX Hydro-Retriever 265HD

Convertamatic 265LX Hydro-Retriever 265HD Convertamatic 265LX Hydro-Retriever 265HD PARTS LIST Advance MODELS 56393670, 56393675 This parts list is for machines after serial number 1002647 revised 8/00 Form Number 56042286 revised 5/00 FORM NO.

More information

Encore S28/L28/S33/L33/S38/L38. Section II. Parts and Service Manual (79049B)

Encore S28/L28/S33/L33/S38/L38. Section II. Parts and Service Manual (79049B) Encore S8/L8/S/L/S8/L8 Section II Parts and Service Manual (9049B) CLARKE TECHNOLOGY Operator's Manual - Encore S8/L8/S/L/S8/L8 - - HOW TO CORRECT PROBLEMS IN THE MACHINE PROBLEM CAUSE ACTION The machine

More information

AMVAC TM technical guide Vacuum circuit breaker with magnetic actuator mechanism

AMVAC TM technical guide Vacuum circuit breaker with magnetic actuator mechanism AMVAC TM technical guide Vacuum circuit breaker with magnetic actuator mechanism AMVAC Universal applications: Medium voltage motor starting applications Capacitor switching Retrofit applications to replace

More information

SURE JET ENVELOPE FINISHING SYSTEM MODEL EFS

SURE JET ENVELOPE FINISHING SYSTEM MODEL EFS SURE JET ENVELOPE FINISHING SYSTEM MODEL EFS SURE JET VACUUM BASE SJVB SURE JET VACUUM BASE SJDB-EXT Parts Manual SJ_EFS-PARTSBOOK051507reva 1 TABLE OF CONTENTS ENVELOPE FINISHING SYSTEM- SURE JET EFS-SURE

More information

www. ElectricalPartManuals. com GENERAL. ELECTRIC RENEWAL PARTS CR7006-C100, -C101 AND -C102 MAGNETIC STARTERS

www. ElectricalPartManuals. com GENERAL. ELECTRIC RENEWAL PARTS CR7006-C100, -C101 AND -C102 MAGNETIC STARTERS RENEWAL PARTS CR7006-C100, -C101 AND -C102 MAGNETC STARTERS CR7006-C1 OOA, -C1 008, -C1 OOC, -C1 000, -C1 01 A, -C1 01 B, -C1 01 C, -C1 010, -C1 01 Q, -C1 02A, -C1 028, -C1 02C, -C1 020 and -C1 02Q GEF-3!5470

More information

CATALOG OF REPLACEMENT PARTS

CATALOG OF REPLACEMENT PARTS CATALOG OF REPLACEMENT PARTS HFD/HFC SERIES FRYERS DRAWER FILTER SYSTEM HFD50F ML-135570 HFD85F ML-135574 HFC50F ML-135571 HFC85F ML-135575 WITHOUT DRAWER FILTER SYSTEM HFD50 ML-135551 HFD85 ML-135553

More information

CR193 B,C,D and E Vacuum Limitamp * Contactors

CR193 B,C,D and E Vacuum Limitamp * Contactors GE Industrial Solutions CR19 B,C,D and E Vacuum Limitamp * Contactors Renewal Parts Bulletin Table of Contents General Information... Contactor Matrix... 4 Mounting Plates, Pull Handle, Interlock Driver

More information

SERVICE PARTS MANUAL

SERVICE PARTS MANUAL SERVICE PARTS MANUAL 28V SERIES SNOW PLOWS FOR PLOW SERIAL NUMBERS AFTER 28VG100000 28VD100000 07 Sno-Way International 9710097F TABLE OF CONTENTS Page PARTS LIST INTRODUCTION... 2 POWER PACK FRAME...

More information

Dynamic Braking Kit for FlexPak 3000 and WebPak 3000 Digital DC Drives 1.5 HP to VAC, 3 HP to VAC without NEMA1 Enclosures

Dynamic Braking Kit for FlexPak 3000 and WebPak 3000 Digital DC Drives 1.5 HP to VAC, 3 HP to VAC without NEMA1 Enclosures Dynamic Braking Kit for FlexPak 3000 and WebPak 3000 Digital DC Drives 1.5 HP to 150 HP @ 230 VAC, 3 HP to 600 HP @ 460 VAC without NEA1 Enclosures odel Numbers 912FKxxxx and 913FKxxxx Instruction anual

More information

Publication No.: PSG

Publication No.: PSG TABLE OF CONTENTS PAGE 1.0 SCOPE...2 2.0 STANDARDS...2 3.0 DESIGN REQUIREMENTS...2 3.01 Service Conditions... 2 3.02 Ratings... 3 3.03 Resistors... 3 3.04 Interrupter... 4 3.05 SF 6 Gas System... 4 3.06

More information

CARGO AND COMBINED CARGO/PASSENGERS (COMBI) CONFIGURATIONS

CARGO AND COMBINED CARGO/PASSENGERS (COMBI) CONFIGURATIONS 2.34. 2.34.1 CARGO AND COMBINED CARGO/PASSENGERS (COMBI) CONFIGURATIONS CARGO CABIN CONFIGURATION To secure the load when stowed in the approved bins, up to twelve tie-down straps and 24 tie-down fittings

More information

HVX Series. 36 kv Medium Voltage Vacuum circuit breaker. Make the most of your energy SM. Medium Voltage Distribution Catalogue 2015

HVX Series. 36 kv Medium Voltage Vacuum circuit breaker. Make the most of your energy SM. Medium Voltage Distribution Catalogue 2015 Medium Voltage Distribution Catalogue 205 HVX Series 36 kv Medium Voltage Vacuum circuit breaker Fixed, middle rolling and floor rolling ranges of circuit breaker and disconnector Make the most of your

More information

CR193 Vacuum Limitamp* Contactors

CR193 Vacuum Limitamp* Contactors GE Electrical Distribution GEH-5306C Maintenance Instructions CR193 Vacuum Limitamp* Contactors Contents Section 1 Introduction... 3 General... 3 Section 2 Description... 4 Principle of Operation... 4

More information

Evolution * Series E9000 Motor Control Center

Evolution * Series E9000 Motor Control Center GE Industrial Solutions Evolution * Series E9000 Motor Control Center Renewal Parts Bulletin Table of Contents Introduction The E9000-Line motor control center, a quality product of the General Electric

More information

KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS

KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS 2001.09 KYN28A-12 (GZS1) A.C Metalclad Removable Switchgear for Indoor Use --------The Leader in Switchgear Up to 12kV 1. The

More information

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher TABLE OF CONTENTS PAGE 1.0 SCOPE... 2 2.0 STANDARDS... 2 3.0 DESIGN REQUIREMENTS... 2 3.01 Service Conditions... 2 3.02 Ratings... 3 3.03 Interrupter... 3 3.04 SF6 Gas System... 4 3.05 Terminal Pads...

More information

Vacuum Switchgear Type VMX Spares Manual

Vacuum Switchgear Type VMX Spares Manual Vacuum Switchgear Type VMX Spares Manual Vacuum Switchgear Type VMX Spares Manual Foreward This manual has been primarily designed for easy identification of components / sub-assembly. Ordering Components

More information

Westinghouse Electric Corporation Distribution and Control Business Unit Assemblies Division Bloomington, Indiana

Westinghouse Electric Corporation Distribution and Control Business Unit Assemblies Division Bloomington, Indiana Supersedes Descriptive Bulletin, pages 1-8, dated January, 1976 Mailed to: E, D, C/38-000F Westinghouse Electric Corporation Distribution and Control Business Unit Assemblies Division Bloomington, Indiana

More information

Power Break Circuit Breakers

Power Break Circuit Breakers Draw Out 800-4000 Amperes GEH-46988 Installation Instructions Power Break Circuit Breakers POWER BREAK Draw Out Circuit Breaker (SOOA 4000A) DESCRIPTION Types TC, and THC Power Break draw out circuit breakers

More information

MODEL EVA PARTS MANUAL Rev.1.05

MODEL EVA PARTS MANUAL Rev.1.05 MODEL EVA PARTS MANUAL Rev.1.05 CMA DISHMACHINES 12700 KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841 800-854-6417 FAX 714-895-2141 www.cmadishmachines.com TABLE OF CONTENTS MODEL EVA 1. PARTS MANUAL...3

More information

VCP-T/T-VAC medium voltage vacuum circuit breakers. Control and protect with Eaton s compact medium voltage circuit breakers

VCP-T/T-VAC medium voltage vacuum circuit breakers. Control and protect with Eaton s compact medium voltage circuit breakers VCP-T/T-VAC medium voltage vacuum circuit breakers Control protect with Eaton s compact medium voltage circuit breakers Eaton Corporation has dedicated years of research, design testing to create a comprehensive

More information