1 Data ubject to change without notice. RENEWAL PARTS POWER CIRCUIT BREAKERS TYPES 225 AMP FRAME SIZE 00 AMP FRAME SIZE GEF-449G Supersedes GEF-449F AK-2-5 AK-2-25 AK-3-25 AKF-2-25 AK-2A-5 AK-2A-25 AK-3A-25 AKF-2A-25 AKU-2-25 AKU-3-25 AKU-2A-25 AKU-3A-25 Fig.. Type AK-2-25 manually operated power circuit breaker ORDERING INSTRUCTIONS. Always specify the complete nameplate data of the breaker. (PHOTO ) 2. Specify the quantity, catalog number (if listed), reference number (if listed), description, and this bulletin number. 3. CAUTION: When local facilities for breaker recalibration are not available, the breaker should be forwarded to the nearest G-E Service Shop, or to the General Electric Company, 90 Elmwood Avenue, Philadelphia 42, Pa. 4. Standard hardware, such as screws, bolts, nuts, washers, etc., is not listed in this bulletin. Such items should be purchased locally. 5. For prices, refer to the nearest office of the General Electric Company. GENERAL. ELECTRIC

2 GEF (PHOTO ) fig. 2. Type AK-2-25 power circuit breaker back frame (operating mechanism removed) A " 29 '-= 3 4 Fig. 4. Cutaway view of type AK-2-25 electrically operated power circuit breaker 2 30 II j r h, Fig. 2A. Spring (back of pivot) ?! cf j j 2A Fig. 3. Moving and stationary contacts and cross bar assembly SA (PHOTO ) Fig. 5. Type AK-2-25 electrically operated power circuit breaker (escutcheon removed and dismantled)

3 Quantity Required Ref. for 3 -pole Breaker Catalog No. Frame Size Number 225 Amp** 00 Amp** la 227D90P Back plate C20G Insulation for upper stud, rear tlb C20G2 Insulation for upper stud, front C2S3G Upper stud assembly C2S3G2 Upper stud assembly B40P Barrier *4 3 29C257G Stationary contact assembly 3 29C257G2 Stationary contact assembly *5 * 3-29C257G4 Moving contact * C257G5 Moving contact * A250 Spring (outside poles) Description *7A 29C2SOP5 Spring clip (center pole) s C277P9 Barrier SA 29C277P0 Barrier, complete (includes Ref. Nos. S and SA) 9.29C277Gl Cross bar assembly C25SG3 Pivot * C2SOPS Spring (back of pivot) C25SG Lower stud assembly (not used on AK-3 or AK-3A) C25SG2 Lower stud assembly C52P Insulation (under lower stud) C2SOP7 Support (outside) C2SOP Support (intermediate) B2SSG Arc quencher 7-2C754G2 Arc quencher clamp AK -3 or 3A only 7 29C273G2 Arc quencher clamp (sand gray) AK-2 or 2A S C2SOP4 Stud, arc quencher clamp tl L25P29 Insulation for Ref. No. S t A993P9 Stop nut for Ref. No. S *2 2 42A2S Stationary contact spring 2A A20S Movable contact spring 2B 29C277Pll Spring clip t22 29C2SOP Moving contact pivot pin (center pole) C2SOP2 Moving contact pivot pin (outside poles) *24 042A0290 Spring 25 22C52G omagnet and armature assembly 2 See table B oclo sing coil See note below Overcurrent trip device 2S 3SA3P Clamp for EC -2 trip device 2S P Clamp for EC- trip device 29-29C2SP5 Retaining ring 29-29C2SlP Retaining ring S45C27G2 Primary disconnect assembly 30-3 S45C27G4 Primary disconnect assembly 30A 42A222 Spring C2SP3 Retainer * A00P2 Contact finger A29P Retainer A29P2 Retainer ASP4 Spacer Screw, hex. hd, /4 in. -20 by 3 /2 in. * Recommended for stock for normal maintenance. t Not shown. ** See breaker nameplate for frame size. 5 Electrically operated breakers Note for overcurrent trip devices: () No parts furnished for field installation on EC- trip devices. GEF-449G (2) Only part furnished for field installation on EC-2 or EC-2A trip devices is plastic cover, Cat. No. 242C45Pl. (3) When replacement trip devices are ordered, it is imperative that order includes complete nameplate reading of the breaker or breakers involved and, if a contemplated ampere rating change is involved, the order should also include information as to ampere rating, time-current characteristic, and instantaneous trip setting desired. Note for operating mechanisms: () Individual parts cannot be furnished for operating mechanisms. (2) When replacement is necessary give complete nameplate reading when ordering. 3

4 GEF-449G Quantity Required Ref. for 3-pole Breaker No. Frame Size 225 Amp** 00 Amp** t39a t t43a t44 t44 t *48 t49 A* 50 A* 5 TA52 TA*52A TA*52B TA52C A*53 A 54 A 55 * *58 59 *t maximum 4 maximum Catalog Number 38All0G2 22C505G 432A7G2 432A7G5 29C28P 29C28P2 42A33 22C502G 22C529G 0C789G 0C789G2 259C07G 259C07P0 259C07G2 259C07G3 259C07Pll 259C07G4 259C08G 27B9P 9D807P 48A B445P22 295B445P B445P223 B797P22 B797P223 llb797p222 22C50P 22C50P2 29C282G2 29C282G5 t t C299G G G274 84C85G 3493P 3493P2 3493P3 295B475P2 394Al44P 275B995P 95C3P 394A0P 457A73G 29C27G2 * Recommended for stock for normal maintenance. ** See breaker nameplate for frame size. t Not shown. Description Movable secondary disconnects (drawout breaker) Cutoff switch (electrically operated breaker) Auxiliary switch, 2 stages Auxiliary switch, 5 stages Manual trip button Trip label Spring for manual trip button Shunt trip device with coil Closing switch Shaft assembly (Manual Breaker only) order Ref. 43 and 43A together Link assembly Escutcheon, manual breaker (black) Escutcheon, electrically operated breaker (black) Escutcheon, electrically operated breaker (with handle) (black) Escutcheon, manual breaker (blue) Escutcheon, electrically operated breaker (blue) Escutcheon, electrically operated breaker (blue) with pistol grip handle Indicator Handle (black) Handle (gray) "X" relay (see Table A, page ) "Y" relay (see Table A, page ) Return spring, rear of escutcheon Stationary contacts, "X" relay / On early AK -2-5, AK-2-25 and Moving contacts, "X" relay \, AKF-2-25 With.. o suffix number Springs, moving contacts, "X" relay Stationary contacts, "X" relay / Molded moving arm, "X" relay (with moving contacts) \ all others Armature return spring, "X" relay. Operating coil, "X" relay (see Table A, page ) Cover, "X" relay ( On early AK -2-5, AK-2-25 and AKF Jumper, "X" relay f with no suffix number Coil for shunt trip device (see Table B, page 7) tinstantaneous undervoltage device, a-c (with coil) tinstantaneous undervoltage device, d-e (with coil) Time -delay undervoltage device, a-c Time -delay undervoltage device, d-e Coil for undervoltage device (see Table B, page 7) Static time delay, a-c or d-e (replaces complete time delay and volt device coil only) Spring, for undervoltage device :t:bell alarm device Terminal board, terminals Terminal board, 0 terminals Link and bushing for auxiliary switch Cover for auxiliary switch, stage Cover for auxiliary switch, 2 stages Cover for auxiliary switch, 5 stages Base for wall mounted, general purpose breaker Angle for wall mounted, general purpose breaker Terminal for wall mounted, general purpose breaker Terminal for wall mounted, general purpose breaker Cable clamp for wall mounted, general purpose breaker Cable clamp for wall mounted, general purpose breaker Maintenance handle t If at any time a breaker is to have added to it either shunt trip, undervoltage device, or bell alarm device, the order for the device must include the following information: () Complete nameplate reading of breaker involved. (2) Desired voltage rating of device, whether a-c or d-e, and if a -c, the frequency. (3) In the case of undervoltage devices, specify whether instantaneous or time delay. A On -, specify Cat. No. of "X" relay when ordering these parts. b. Order by circuit breaker Serial No. 4 www. ElectricalPartManuals. com

5 C 53 fig. 0. Cutoff switch (ref. 37) fig.. "X" contactor (ref. 47) fig.. Bell alarm device (ref. ) fig. 7. "y" relay (ref. 48) Fig. 2. Termmal board (ref. 2) 5 fig. 8. Shunt trip device (ref. 4) fig. 3. Auxiliary switch (ref. 38) fig J! 57 s,'"irj 58 Time delay undervoltage device (ref. 57) fig. 3A.. ElectricalPartManuals. co Static time delay m., 0 m :;a Q :;a n c: =i "' :;a m m :;a "' '>:! I ""... ""

6 GEF -449G NOTES FOR FIG. 4: Fig. 4. Manual (left) and electrical (right) front frame assemblies for Type AK-2-5 and -25 power circuit breakers (PHOTO ) () Should it become necessary to replace the complete front frame of the breaker, it is necessary that the order include complete nameplate reading of existing breaker. (2) f an existing manual breaker is to be converted to electrical operation, the order must include, in addition to Rating complete nameplate reading, a description of desired change and complete voltage and frequency rating of both closing and tripping circuits. TABLE A Catalog Number "X" Relay_ Relay Coil, only Relay Coil, only Complete, Ref. 47 (Ref. 53) Complete, Ref. 47 (Ref. 53) Volts Cycles tor fl. and Early - for Late -, and all -2 Breakers B445Pl 295B445P20 295B445P2 295B445P202 D-C B445P3 295B445P B445P4 295B445P B445P7 295B445P B445P0 295B445P B445P3 295B445P B445P2 295B445P B445P 295B445P20 ' 208 "I B445P9 295B445P B445Pl2 295B445P B445P7 295B445P B445P5 295B445P2 295B445P5 295B445P B445P8 295B445P B445Pll 295B445P2 fl B445P4 295B445P25 Original breaker had no suffix numeral or letter. Only complete relay furnished. B797Pl B797P2 B797P3 B797P4 B797P7 B797P0 B797P3 B797P Breakers B797P20 B797P202 B797P203 B797 P204 B797 P207 B797P20 B797P23 B797P B797P B797P9 B797Pl2 B797P7 B797P5 B797P5 B797P8 B797 Pll B797P4 B797P20 B797P209 B797P22 B797P27 B797P25 B797 P205 B797P208 B797P2 B797P24 "Y" Relay Complete (Ref. 48) 295B444Pl 295B444P2 295B444P3 295B444P4 295B444P7 295B444Pl0 295B444P B444Pll 295B444P5 295B444P8 295B444Pll 295B444Pl7 295B444P4 295B444P5 295B444P8 295B444Pll 295B444P4

7 Fig 5. Accessories for wall mounting (ref. 5,, 7, 8) Volts Rating Cycles Closing Solenoid Coil (Ref. 2) A77307 D-C 25 3A A A A A773G4 40 3A A A A A A A A A A A A A77309 TABLE B (PHOTO 80258) Fig.. Maintenance handle for electrically operated breakers not equipped with manual handles (ref. 9) Catalog Number Undervoltage Device Coil (Ref. 58) Shunt Trip Instantaneous Device or Old Design Coil Oil Dashpot Type Static Time (Ref. 5) Time Delay Delay Type h Tinput voltage to static timing unit (Fig. 3A) indicated. OEF

8 GEF-449G Without ground trip Fig. 7. Magnetic coil assembly Magnetic Sensor Coils - Assem bly (Fig 7) With ground trip Poles Rating Cat. No. Poles Rating Grd. Trip Range Cat. No. 8 www 2 45/225 07D7554G2 2 45/225 00/400 07D7554G 3 45/225 07D7554G3 3 45/225 00/400 07D7554G /00 07D7554G /00 00/400 07D7554G /00 07D7554G /00 00/400 07D7554G /00 300/200 07D7554G /00 300/200 07D7554Gll Fig. 8. Power supply unit Power Supply Units - Cat. No. 5C4508G0 Fig. 9. Power sensor unit. ElectricalPartManuals. com

9 With Ground Fault Protection 00 to 400 Amp Range Power Sensor Unit AK-25 (Fig. 9) With Instantaneous Trip With Instantaneous Trip Without Instantaneous 4 to 2X Range 4 to 2X Range Trip Without Short Time Delay 84L373G57 84L373G With Short Time Delay 2 to 5X Range 84L373G5 84L373G 84L373G0 4 to OX Range 84L373G54 84L373G9 84L373G3 Without Ground Fault Protection Without Short Time Delay 84L373G43 84L373G50 With Short Time Delay 2 to 5X Range 84L373G4 84L373G4 84L373G44 4 to lox Range 84L373G42 84L373G47 84L373G45 Fig. 20. Magnet trip device with mounting bracket Magnet Trip Device with Mounting Bracket - Cat. No. 084C0882 G4 Fig. 2. Ground sensor coil with neutral mounting Fig. 22. Power sensor kit Fourth Wire Grid Sensor Coils 00/400 Cat. No. 52C928Gl 300/200 Cat. No. 52C928G GEF-449G With Long Time Delay Without Long Time With Long Time Delay Without Long 80 to 30% Range Delay 80 to 30% Range Time Delay Power Sensor Test Kit- Cat. No. Without Instantaneous Trip L373G72 84L373G L373G48 84L373G49 002D252 GlO 9

10 GEF-449G 24 OUTS I DE POLE CONTACTS AND BARRIER 25 2 ' CE NTER POLE AND FIELD SWITCH MECH " 0----J Ill / 3 ---/ I I 4 ---/ " Fig. 2'3. Field switch mechanism and contact assemblies r---i""""c'r--- tttt== l7 NOTE: Parts listed below apply only to Types AKF-2-25 and AKF-2A-25. All other parts are identical to those used on Type AK Ref. Qty. Per No. Center Pole Catalog No. Description C997P9 Insulation *0 08C998Gl Moving contact C995P2 Link A33P8 Retaining ring 04 08C995P9 Pin A2279Pl Adjustable bushing A87P2 Bearing 07 08C995P0 Cam follower 08 08C99G Crossbar 09 08C995G3 Cam assembly, left 09 08C995G4 Cam assembly, right 0 08C995P Pivot 08C994P8 Lower stud insulation 2 08C995P3 Connector A33P9 Retaining ring *Recommended for stock for normal maintenance. 0 tnot shown. Ref. Qty. Per No. Center Pole Catalog No. Description A404P3 Pin 5 l08c994p7 Lower pivot * 29C257Gl stationary contact * 29C257G2 Stationary contact A28 stationary contact spring 8 29C283G4 Upper stud 9 08C997Pll Contact spacer right side 9 08C997P2 Contact spacer left side 20 29C280Pl Moving contact pivot pin 2 08C998P4 Spacer 22 29C258G3 Lower stud tl23 293B288Gl Arc quencher 24 08C997G3 Insulation *25 08C998G2 Moving contact C994P5 Spring

11 MEMORANDUM

12 2-80 (3M) GENERAL ELECTRIC CO. DISTRIBUTION EQUIPMENT 0 IV IS ION PLAINVILLE, CONN. 002 GENERAL fj ELECTRIC

www. ElectricalPartManuals. com POWER CIRCUIT BREAKERS TYPES AK-2/3/2A/3A-50, AKU-2/3/2A/3A-50, AKT-2/3/2A/3A-50 GENERAL fj ELECTRIC

www. ElectricalPartManuals. com POWER CIRCUIT BREAKERS TYPES AK-2/3/2A/3A-50, AKU-2/3/2A/3A-50, AKT-2/3/2A/3A-50 GENERAL fj ELECTRIC ORDERNG NSTRUCTONS. Always specify complete nameplate data of the breaker. 2. Specify the quantity, catalog number (if listed), reference number (if listed), description, and this bulletin number. 3. Standard

More information

Frame Sizes: AKJ/ AKJT I AKJU-50 and AKR/ AKRU-30/ 50, AKRT-50

Frame Sizes: AKJ/ AKJT I AKJU-50 and AKR/ AKRU-30/ 50, AKRT-50 RENEWAL PARTS LOW VOLTAGE POWER CIRCUIT BREAKERS Frame Sizes: AKJ/ AKJT I AKJU-50 and AKR/ AKRU-30/ 50, AKRT-50 GEF-4527F Supersedes GEF-4527E TABLE A. INDEX OF BREAKER MODELS COVERED BY THIS PUBLICATION

More information

www. ElectricalPartManuals. com Type AM Magne-Biast Circuit Breakers RENEWAL PARTS

www. ElectricalPartManuals. com Type AM Magne-Biast Circuit Breakers RENEWAL PARTS RENEWAL PARTS Ordering Instructions 1. Always specify the complete nameplate data of the breaker. 2. Specify the quantity, catalog number (if listed), reference number (if listed) description, and this

More information

BBC. Renewal Parts. I-T-E Low-Voltage Power Circuit Breakers

BBC. Renewal Parts. I-T-E Low-Voltage Power Circuit Breakers BBC BROWN BOVERI RP 6..2.8-2C Renewal Parts I-T-E Low-Voltage Power Circuit Breakers Type K-000, 4000, 0008, and 40008 Stationary and Drawout Mounted 000 and 4000 Amperes 600 Volts RP 6..2.8-2 Page 2 Table

More information

CD5--- CA4--- CD6---- CB2---- CB4---- PARTS RECOMMENDED FOR NORMAL STOCK

CD5--- CA4--- CD6---- CB2---- CB4---- PARTS RECOMMENDED FOR NORMAL STOCK RENEWAL PARTS CA2--- CD5--- CA4--- CD6---- CB2---- CB4---- ' PARTS RECOMMENDED FOR NORMAL STOCK NOTE: The current is identified by the number following the voltage letter in the IC designation. EXAMPLE:

More information

GEF Renewal Pans. low Vohage Power Circuit Breakers. Type AKR-30S and AKRU-30S. www. ElectricalPartManuals. com

GEF Renewal Pans. low Vohage Power Circuit Breakers. Type AKR-30S and AKRU-30S. www. ElectricalPartManuals. com -- GEF-6005 Renewal Pans low Vohage Power Circuit Breakers Type AKR-30S and AKRU-30S INTRODUCTION This manual provides a listing of the parts and assemblies that are availle as replacement parts for low

More information

DEF 005. WavePro Power Circuit Breakers A Frames, Vac. Renewal Parts

DEF 005. WavePro Power Circuit Breakers A Frames, Vac. Renewal Parts g DEF 005 WavePro Power Circuit Breakers 3200 5000 A Frames, 240 600 Vac Introduction This guide contains a listing of the parts and assemblies that are available as replacement parts for WavePro 3200

More information

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut

Page 2 DS LOW VOLTAGE POWER CIRCUIT BREAKERS Digitrip Trip Unit Inside Wiring Guide Outside Wiring Guide Shutter Drawout Unit Position Indicator Escut Page 1 Supersedes Renewal Parts Data 33-790-1G pages 1-20 dated December, 1988 Mailed to: C, D, E/33-700 Westinghouse DS and DSL Low Voltage Power Circuit Breakers and Cell Parts Contents Pages DS Breaker

More information

RENEWAL PARTS I C302AA A-2 300V AB A-4800V A C A -SOOOV PARTS RECOMMENDED FOR NORMAL STOCK

RENEWAL PARTS I C302AA A-2 300V AB A-4800V A C A -SOOOV PARTS RECOMMENDED FOR NORMAL STOCK NGrE: RENEWAL PARTS IC0A HIGH VOLTAGE CONTACTORS I C0AA 00A 00V AB00A800V A C 00A SOOOV PARTS RECOMMENDED FOR NORMAL STOCK The current is identified by the number following the voltage letter in the IC

More information

www. ElectricalPartManuals. com Type AM ,-6 Magne-Biast Circuit Breakers RENEWAL PARTS GENERAL. ELECTRIC GEF-4438A Supersedes GEF-4438

www. ElectricalPartManuals. com Type AM ,-6 Magne-Biast Circuit Breakers RENEWAL PARTS GENERAL. ELECTRIC GEF-4438A Supersedes GEF-4438 Ordering Instructions RENEWAL PARTS 1. Always specify the complete nameplate data of the relay, including complete model of relay. 2. Specify the quantity, catalog number (if listed), reference number

More information

Instruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035

Instruction Bulletin. DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 6035 Instruction Bulletin 4402-997-0 February 999 Middletown, OH, USA DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker Replacement Parts Class 605 DS/DSL and DSII/DSLII Low Voltage Power Circuit Breaker

More information

www. ElectricalPartManuals. com BBC Brown Boveri Electric Renewal Parts 1-T -E Low-Voltage Power Circuit Breakers

www. ElectricalPartManuals. com BBC Brown Boveri Electric Renewal Parts 1-T -E Low-Voltage Power Circuit Breakers i BBC BROWN BOVERI Type LK and LKE 800 thru 4200 Amperes Type LKD 800 and 1600 Amperes 600 Volts RP 6118A Renewal Parts 1-T -E Low-Voltage Power Circuit Breakers Brown Boveri Electric RP 6118-1A Page 2

More information

www. ElectricalPartManuals. com

www. ElectricalPartManuals. com SPEC-SETTER Type TH HEAVY DUTY SAFETY ES LOAD BLOCK CATALOG MODEL NUMBER NO. BLOCK THJ 343L68G97 TH M 343L68G97 THMK 343L68G97 THMSS 343L68G97 THSS 343L68G97 THJ 343L68G0 THM 343L68G0 THMK 343L68G0 THMSS

More information

www. ElectricalPartManuals. com Cutler-Hammer Power Breaker Center Renewal Parts for Low Voltage Power Circuit Breakers Types DB, DBL and DBF

www. ElectricalPartManuals. com Cutler-Hammer Power Breaker Center Renewal Parts for Low Voltage Power Circuit Breakers Types DB, DBL and DBF New Information Control Relay Auxiliary Switch Operating Mechanism CutlerHammer Power Center 10 Maxwell Avenue Greenwood, SC 29646 1877276979 Closing Solenoid 2254 Renewal Parts for Low Voltage Power Circuit

More information

www. ElectricalPartManuals. com GENERAL. ELECTRIC RENEWAL PARTS CR7006-C100, -C101 AND -C102 MAGNETIC STARTERS

www. ElectricalPartManuals. com GENERAL. ELECTRIC RENEWAL PARTS CR7006-C100, -C101 AND -C102 MAGNETIC STARTERS RENEWAL PARTS CR7006-C100, -C101 AND -C102 MAGNETC STARTERS CR7006-C1 OOA, -C1 008, -C1 OOC, -C1 000, -C1 01 A, -C1 01 B, -C1 01 C, -C1 010, -C1 01 Q, -C1 02A, -C1 028, -C1 02C, -C1 020 and -C1 02Q GEF-3!5470

More information

CR193 B,C,D and E Vacuum Limitamp * Contactors

CR193 B,C,D and E Vacuum Limitamp * Contactors GE Industrial Solutions CR19 B,C,D and E Vacuum Limitamp * Contactors Renewal Parts Bulletin Table of Contents General Information... Contactor Matrix... 4 Mounting Plates, Pull Handle, Interlock Driver

More information

GEF-4647A. GE Drive Systems. Renewal Parts. HEAVY DUTY DC CONTACTORS DS303Al (600V STYLE) DS303Bl (looov STYLE) www. ElectricalPartManuals.

GEF-4647A. GE Drive Systems. Renewal Parts. HEAVY DUTY DC CONTACTORS DS303Al (600V STYLE) DS303Bl (looov STYLE) www. ElectricalPartManuals. GEF4647A GE Drive Systems Renewal Parts HEAVY DUTY DC CONTACTORS DS303Al (600V STYLE) DS303Bl (looov STYLE) DS303 A 1 A 01 A B c AF 11A TABLE 1 NAMEPLATE DENTFCATON OF CONTACT A 1 Normally open POLE CONFGURATON

More information

www. ElectricalPartManuals. com GENERAL. ELECTRIC RENEWAL PARTS METAL-CLAD SWITCHGEAR TYPES M-26 AND M-36 GEF-4351C Supersedes GEF-4351B

www. ElectricalPartManuals. com GENERAL. ELECTRIC RENEWAL PARTS METAL-CLAD SWITCHGEAR TYPES M-26 AND M-36 GEF-4351C Supersedes GEF-4351B Data subject to change without notice. RENEWAL PARTS METAL-CLAD SWTCHGEAR TYPES M-26 AND M-36 ORDERNG NSTRUCTONS 1. Always specify the complete nameplate data of the equipment. GEF-4351C Supersedes GEF-4351B

More information

ProTrip Conversion Kits. For GE Types AK-15, AK-25, and AKU- 25 Low-Voltage Power Circuit Breakers INTRODUCTION. DEH Installation Instructions

ProTrip Conversion Kits. For GE Types AK-15, AK-25, and AKU- 25 Low-Voltage Power Circuit Breakers INTRODUCTION. DEH Installation Instructions DEH 40026 Installation Instructions g ProTrip Conversion Kits For GE Types AK-15, AK-25, and AKU- 25 Low-Voltage Power Circuit Breakers INTRODUCTION GE Conversion Kits are designed for upgrading existing

More information

Instructions for A200, A210, A250 size 6, two- or three-pole non-reversing or reversing motor controllers

Instructions for A200, A210, A250 size 6, two- or three-pole non-reversing or reversing motor controllers Instruction Leaflet IL0330300E Supersedes I.L. 7055C, Pages 8, Dated June 998 Instructions for A00, A0, A50 size 6, two- or three-pole non-reversing or reversing motor controllers Contents Description

More information

Magnetic Overload Relays

Magnetic Overload Relays Magnetic Overload Relays Series N147 Series N147 Overload Relays are of the magnetically operated self reset type, designed for use on or motor starters and controllers for Navy Service A applications.

More information

920 Remote Control Switches

920 Remote Control Switches 920 Remote Control Switches REMOTE CONTROL SWITCHES Service Bulletin This service bulletin for ASCO 920 Remote Control Switches explains how to replace the main s, operator coil, control s, and how to

More information

Low Voltage Power Circuit Breakers

Low Voltage Power Circuit Breakers A-TYPE DRAWOUT Electrically Operated I GE/-861508 Installation Instructions Low Voltage Power Circuit Breakers Types AKR-30/50 and A -50 0-TYPE ORA WOUT \ Manually Operated B-TYPE DRAWOUT Electrically

More information

www. ElectricalPartManuals. com RENEWAL PARTS DATA Westinghouse Electric Corporation WESTINGHOUSE EQUIPMENT FOR FURNISHED TO

www. ElectricalPartManuals. com RENEWAL PARTS DATA Westinghouse Electric Corporation WESTINGHOUSE EQUIPMENT FOR FURNISHED TO RENEWAL PARTS DATA FOR WESTINGHOUSE EQUIPMENT FURNISHED TO WESTINGHOUSE ELECTRIC CORPORATION Sharon Plant Sharon Pennsylvania Purchaser's Order C&E-D-44252 G.O. XY-9286-UY-UR - S.O. 2-Y-774 SWITCHGEAR

More information

A - Add New Information C - Change Existing Information D - Delete Information. Page 7. Delete the fourth paragraph beginning CAUTION

A - Add New Information C - Change Existing Information D - Delete Information. Page 7. Delete the fourth paragraph beginning CAUTION ABB Effective: November 1990 This Addendum Supersedes all Previous Addenda Addendum to Instruction Leaflet 41-137.3H Type KRD-4 Directional Overcurrent Ground Relay A - Add New Information C - Change Existing

More information

Westinghouse Molded Case Circuit Breakers Engine Generator FG Amperes

Westinghouse Molded Case Circuit Breakers Engine Generator FG Amperes Circuit s FG 15-150 Amperes Description Page Type FG Three-Pole... 1 Type JG Three-Pole... 3 Type KG Three-Pole... 5 Type G Three-Pole... 7 Type MG Three-Pole... 9 Type NG Three-Pole... 11 Cutler-Hammer

More information

VacClad-W type VCP-W 5 and 15 kv, 36-inch-wide switchgear components

VacClad-W type VCP-W 5 and 15 kv, 36-inch-wide switchgear components Supersedes July 2002 Contents Page Procedure for identifying parts... 2 Customer ordering instructions.... 2 Distributor ordering instructions.... 2 Front panel components.... 3 Breaker pan assembly....

More information

FULL VOLTAGE STARTERS z SIZE 8 SERIES B CONSTRUCTION

FULL VOLTAGE STARTERS z SIZE 8 SERIES B CONSTRUCTION 505 z 509 FULL VOLTAGE STARTERS z SIZE 8 SERIES B CONSTRUCTION The movable contacts are carried in stainless steel cages which in turn are mounted in cavities in the molded portion of the cross bar. This

More information

FOR PRICES ON DSII and DSLII BREAKERS, REFER TO PRICE LIST PL.22B.01.P.E

FOR PRICES ON DSII and DSLII BREAKERS, REFER TO PRICE LIST PL.22B.01.P.E Supersedes PL.44B.04.P.E Dated September 1998 600 Volts AC Maximum 200 ka, RMS Sym. Short Circuit Maximum 800-5000 Amps Continuous Effective: October 1999 Page 1 Index Page Table Description/Application...

More information

Industrial Control Transformers

Industrial Control Transformers 6 Industrial Control Transformers Section 6 Industrial Control Transformers provide a low and safe control voltage for the operation of electromagnetic devices, such as motor starters, contactors, solenoids

More information

Q and M-Frame Circuit Breaker Instruction Leaflet for Installation and Operation for Thermal Magnetic Trip Units

Q and M-Frame Circuit Breaker Instruction Leaflet for Installation and Operation for Thermal Magnetic Trip Units Q and M-Frame Circuit Breaker Instruction Leaflet for Installation and Operation for Thermal Magnetic Trip Units Bul. 140U DO NOT ATTEMPT TO INSTALL OR PERFORM MAINTENANCE ON EQUIPMENT WHILE ITS IS ENERGIZED.

More information

Cutler-Hammer. Installation Instructions for Undervoltage Release Mechanism (Handle Reset) with LED for E 2 L and E 2 LM Mining Circuit Breakers

Cutler-Hammer. Installation Instructions for Undervoltage Release Mechanism (Handle Reset) with LED for E 2 L and E 2 LM Mining Circuit Breakers Cutler-Hammer Installation Instructions for Undervoltage Release Mechanism (Handle Reset) with LED for E 2 L and E 2 LM Mining Circuit Breakers CONTACT WITH ENERGIZED EQUIPMENT CAN RESULT IN DEATH, SEVERE

More information

GENERAL. ELECTRIC RENEWAL PARTS IC302E HIGH VOLTAGE CONTACTORS. EA A-2300V IEl A-4800V l:c a-sooov

GENERAL. ELECTRIC RENEWAL PARTS IC302E HIGH VOLTAGE CONTACTORS. EA A-2300V IEl A-4800V l:c a-sooov RENEWAL PARTS IC0E HIGH VOLTAGE CONTACTORS EA7----700A-00V IE7 ----700A-800V :C7----700A-SOOOV PARTS RECOMMENDED FOR NORMAL STOCK (a forms) Ref. Cataog Num' )er ---------- 7 5A58P 8 5A9G, 9B8G 5A9G 77B5P

More information

Parts Manual. Transfer Switch. OTPCB (Spec A) 150/225/260 Amps. English Original Instructions (Issue 4)

Parts Manual. Transfer Switch. OTPCB (Spec A) 150/225/260 Amps. English Original Instructions (Issue 4) Parts Manual Transfer Switch 50/225/260 Amps OTPCB (Spec A) English Original Instructions -203 962 0228 (Issue ) This catalog covers models produced under the Cummins /Onan and Cummins Power Generation

More information

CATALOG OF REPLACEMENT PARTS HQC QUICKCHILLS. A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO FORM (June 2001)

CATALOG OF REPLACEMENT PARTS HQC QUICKCHILLS. A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO FORM (June 2001) CATALOG OF REPLACEMENT PARTS HQC QUICKCHILLS HQC135 HQC200 ML-124045 ML-124046 A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 FORM 43009 (June 2001) 28 PRB1 PRB2 PRB3 6 27 11

More information

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Instructions for Replacing

Instructions for Replacing e Instructions for Replacing Vacuum Bottle Subassemblies a on Type SJA, SJS and SJO 360 Amp Contactors l.l. 16-200-348 This l.l. includes illustrations and instructions for replacing vacuum bottle subassemblies

More information

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English. -174 Series C Molded Case Circuit s July 7 Molded Case Switches Refer to Eaton for UL listed, series tested Molded Case Switch application data. Table -278. Molded Case Switches Cont. Amp Rating at 40

More information

Evolution * Series E9000 Motor Control Center

Evolution * Series E9000 Motor Control Center GE Industrial Solutions Evolution * Series E9000 Motor Control Center Renewal Parts Bulletin Table of Contents Introduction The E9000-Line motor control center, a quality product of the General Electric

More information

Selection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker

Selection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker Selection and Application Guide Supplement WL UL1066 4-Pole Circuit Breakers usa.siemens.com/wlbreaker WL Power Circuit Breaker Table of Contents Ratings for UL 1066 (ANSI C37) Circuit Breakers Frame size

More information

PoweMr' With 18 Mechanism '. 1 . / ,, ( c :11t

PoweMr' With 18 Mechanism '. 1 . / ,, ( c :11t ) rvac Vacuu m Circuit. Breaker PoweMr' With 8 Mechanism L- '.. /,, ( (' p c :t ) FRONT VIEW,. 0 3 Fig. Front View of Breaker with Front Cover 3. COUNTER 0. INTERRUPTER ASSEMBLY Fig. 2 Front View of Breaker

More information

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified

More information

Instructions for Installation, Operation and Maintenance of Low Voltage Power Circuit Breakers Types DSII and DSLII

Instructions for Installation, Operation and Maintenance of Low Voltage Power Circuit Breakers Types DSII and DSLII Effective July 2010 Supersedes July 1997 IB694C694-02 Instructions for Installation, Operation and Maintenance of Low Voltage Power Circuit Breakers Types DSII and DSLII Effective July 2010 PURPOSE This

More information

Multi-Pak Group Control

Multi-Pak Group Control Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder

More information

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866) .4 Miniature Circuit Breakers and Supplementary Protectors SPHM Supplementary Protector SPHM Supplementary Protector Product Description The SPHM Supplementary Protector is a dual rated product for both

More information

Q and M-Frame Circuit Breakers Instruciton Leaflet for Alarm Switch and Auxiliary Switch Combinaiton

Q and M-Frame Circuit Breakers Instruciton Leaflet for Alarm Switch and Auxiliary Switch Combinaiton Bul. 140U Q and M-Frame Circuit Breakers Instruciton Leaflet for Alarm Switch and Auxiliary Switch Combinaiton! WARNING CONTACT WITH ENERGIZED EQUIPMENT CAN RESULT IN DEATH, SEVERE PERSONAL INJURY, OR

More information

SIEMENS. Series 8100oT Vacuum Controllers. www. ElectricalPartManuals. com. Bulletin CC

SIEMENS. Series 8100oT Vacuum Controllers. www. ElectricalPartManuals. com. Bulletin CC c c SIEMENS Series 8100oT Vacuum Controllers Bulletin CC3802-02 Technological Development Vacuum technology has developed rapidly in recent years and is becoming widely accepted for medium voltage motor

More information

Crane Control Class 6131

Crane Control Class 6131 Catalog 17 CONTENTS Description.....................................................Page General Information and Pricing........................................ 66 Controller Modifications..............................................

More information

Cutler-Hammer I.L. 29C160G WARNING NOTICE 1-0 INTRODUCTION. General Information

Cutler-Hammer I.L. 29C160G WARNING NOTICE 1-0 INTRODUCTION. General Information Cutler-Hammer Installation Instructions for Undervoltage Release Mechanism (Handle Reset) for EHD, FDB, FD, HFD, FDC, FW, HFW, FWC Circuit Breakers and Molded Case Switches WARNING DO NOT ATTEMPT TO INSTALL

More information

www. ElectricalPartManuals. com

www. ElectricalPartManuals. com Instructions for Parcel-Line Type DH-P Circuit Breakers with Post Insulator Type Pole Units (Supplements I. B. 32-253-2) Westinghouse Electric Corporation Switchgear Division, East Pittsburgh, Pa. 15112

More information

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers Supersedes IL 33-858-4 Dated 05/02 Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers Digitrip Retrofit System for ITE K-3000, Digitrip Retrofit System for ITE K-3000, K-3000

More information

ARMOR QUICK LOCATOR GUIDE. Belts , 380 Brake Components Brushes Capacitors Car Signal Components...

ARMOR QUICK LOCATOR GUIDE. Belts , 380 Brake Components Brushes Capacitors Car Signal Components... QUICK LOCATOR GUIDE Belts.................................................... 366, 380 Brake Components............................................ 380 Brushes......................................................

More information

COM Overcurrent Relay

COM Overcurrent Relay 41-102.1B COM Overcurrent Relay Figure 1: COM-5 Class 1E Relay (Front View) 9664A28 Photo Figure 2: COM-5 Class 1E Relay (Rear View) 9664A29 Photo Photo needed here 2 COM Overcurrent Relay 41-102.1B 3

More information

AC Relays. Type IC5182. Ordering Information. Control Power Requirements. Contact Ratings (Amperes)

AC Relays. Type IC5182. Ordering Information. Control Power Requirements. Contact Ratings (Amperes) AC Relays Type IC5182 Series N147 Overload Relays are of the magnetically operated self reset type, designed for use on A.C. or D.C. motor starters and controllers for Navy Service A applications. Specification

More information

www. ElectricalPartManuals. com outdoor oillnaken type GC aingle tank descrlpllve bullella page l 14.4 lev 100,380 and BOO mva 23 lev 280 mva

www. ElectricalPartManuals. com outdoor oillnaken type GC aingle tank descrlpllve bullella page l 14.4 lev 100,380 and BOO mva 23 lev 280 mva October, 1959 supersedes db 33-ZSl dated November, 1956 mailed to: E/Z75,Z79/DB: D64-5C: CZ6-5Z,b :::....... outdoor oillnaken type GC aingle tank 14.4 lev 1,38 and BOO mva 23 lev 28 mva appucatioa descrlpllve

More information

ABB Power T&D Company Inc. Relay Division Coral Springs, FL Allentown, PA. Non-Directional, Single Phase Adjustable Time Delay Device No.

ABB Power T&D Company Inc. Relay Division Coral Springs, FL Allentown, PA. Non-Directional, Single Phase Adjustable Time Delay Device No. September, 1990 Supersedes Descriptive Bulletin 41-100, pages 1-4, dated June, 1989 Mailed to: E, D, C/41-100A Hi-Lo co induction-disc type overcurrent relays are activated when the current in them exceeds

More information

SERVICE AND REPAIR PARTS NEMA SIZE 5, SINGLE POLE, NORMALLY CLOSED, P/N SERIES NEMA SIZE 5A, SINGLE POLE, NORMALLY CLOSED, P/N SERIES

SERVICE AND REPAIR PARTS NEMA SIZE 5, SINGLE POLE, NORMALLY CLOSED, P/N SERIES NEMA SIZE 5A, SINGLE POLE, NORMALLY CLOSED, P/N SERIES Hubbell Industrial Controls, Inc. SERVICE AND REPAIR PARTS NEMA SIZE 5, SINGLE POLE, NORMALLY CLOSED, P/N 58900 SERIES NEMA SIZE 5A, SINGLE POLE, NORMALLY CLOSED, P/N 59501 SERIES Instructions 5210 Publication

More information

2.0 CONSTRUCTION AND OPERATION 3.0 CHARACTERISTICS K. CO (HI-LO) Overcurrent Relay

2.0 CONSTRUCTION AND OPERATION 3.0 CHARACTERISTICS K. CO (HI-LO) Overcurrent Relay 41-100K 2.0 CONSTRUCTION AND OPERATION The type CO relays consist of an overcurrent unit (CO), either an Indicating Switch (ICS) or an ac Auxiliary Switch (ACS) and an Indicating Instantaneous Trip unit

More information

PowlVac Type PV STD/CDR Vacuum Circuit Breaker

PowlVac Type PV STD/CDR Vacuum Circuit Breaker Instructions PowlVac Type PV STD/CDR Vacuum Circuit Breaker Installation Maintenance Renewal Parts POWELL ELECTRICAL MANUFACTURING COMPANY 8550 MOSLEY DRIVE HOUSTON, TEXAS 77075 USA PHONE (713) 944-6900

More information

3.0 CHARACTERISTICS E Type CO-4 Step-Time Overcurrent Relay

3.0 CHARACTERISTICS E Type CO-4 Step-Time Overcurrent Relay 41-106E Type CO-4 Step-Time Overcurrent Relay A core screw accessible from the top of the switch provides the adjustable pickup range. The IIT contacts are connected in the trip circuit to trip instantaneously.

More information

S4 N 250 B W - 2 xxx. Isomax. Isomax Molded case circuit breakers S3 S8. MCCBs

S4 N 250 B W - 2 xxx. Isomax. Isomax Molded case circuit breakers S3 S8. MCCBs Molded case circuit breakers S3 S8 S4 N 250 B W - 2 xxx Accessories (added in alpha-numeric order) 1 A = Auxiliary Switch BA = Bell Alarm BA3 = Bell Alarm (S6/S7 only) S_ = Shunt trip with voltage code

More information

Page 1 of 9 Knowledgebase Technote ID # Q /24/2006

Page 1 of 9 Knowledgebase Technote ID # Q /24/2006 Page 1 of 9 Knowledgebase Technote ID # Q18356 3/24/2006 Bulletin 520F/520G Multi-Speed NEMA Starters with Eutectic Alloy or Solid-State Overload Relays Sizes 0 through 4 (all series), Size 5 (series L)

More information

Type SOQ Negative Sequence Time Overcurrent Relay

Type SOQ Negative Sequence Time Overcurrent Relay ABB Power T&D Company Inc. Power Automation & Protection Division Coral Springs, FL Allentown, PA April 1998 Supersedes DB dated August 1991 Mailed to: E,D, C/41-100B For Protection of Rotating Machinery

More information

SECTION MOTOR CONTROL

SECTION MOTOR CONTROL SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters

More information

I.L. 29C184A File WARNING

I.L. 29C184A File WARNING CONTACT WITH ENERGIZED EQUIPMENT CAN RESULT IN DEATH, SEVERE PERSONAL INJURY, OR SUBSTANTIAL PROPERTY DAMAGE. DO NOT ATTEMPT TO INSTALL OR PERFORM MAINTENANCE ON EQUIPMENT WHILE IT IS ENER- GIZED. ALWAYS

More information

Parts Manual. Transfer Switch. OTPCC (Spec A) 300/400/600 Amps. English Original Instructions (Issue 4)

Parts Manual. Transfer Switch. OTPCC (Spec A) 300/400/600 Amps. English Original Instructions (Issue 4) Parts Manual Transfer Switch 00/00/600 Amps OTPCC (Spec A) English Original Instructions -20 962 0229 (Issue ) This catalog covers models produced under the Cummins /Onan and Cummins Power Generation brand

More information

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work Section 16435 - SWITCHBOARDS Introduction Part 1 - General Related Work Section 16070 Seismic Anchorage and Restraint Section 16075 Electrical Identification Section 16080 Power Distribution Acceptance

More information

CX-Series. Circuit Breaker

CX-Series. Circuit Breaker CX-Series Circuit Breaker The CX-Series circuit breaker features a unique and innovative arc-quenching configuration that allows the breaker to safely handle high amperage and high DC voltage applications

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw Industrial Generator Set Accessories Line Circuit Breakers 15-2500 kw Standard Features Single Circuit Breaker Kit with Neutral Bus Bar 15-300 kw Model Shown The line circuit breaker interrupts the generator

More information

Motor Control. Motor Control Electrical Aftermarket Products and Services Contents

Motor Control. Motor Control Electrical Aftermarket Products and Services Contents June 00 Aftermarket Solutions, Ref. No. [] - CA0000E Contents Description Page Contactors, Starters & Brakes................................... - Product Description.........................................

More information

[V] Common Control Transformer Control (See page 1-78 Note)

[V] Common Control Transformer Control (See page 1-78 Note) Bulletin NEM Combination Non-Reversing Starters Product Selection Circuit Breaker Type NEM Size Continuous mpere Rating [] Bulletin NEM starter sizes Overload relays: Eutectic supplied as standard, solid-state

More information

VOYTEN ELECTRIC & ELECTRONICS

VOYTEN ELECTRIC & ELECTRONICS VOYTEN ELECTRIC & ELECTRONICS PARTS CATALOG Since 1963, Voyten Electric has become one of the industries leaders in providing new and reconditioned electrical power solutions worldwide. SINCE 1953, VOYTEN

More information

Pro M Miniature Circuit Breakers S260, S270, S280, S290. System Pro M. Description

Pro M Miniature Circuit Breakers S260, S270, S280, S290. System Pro M. Description Miniature Circuit Breakers S260, S270, S280, S290 Description The S2 Series of miniature circuit breakers offer a compact solution to protection requirements. The breakers are recognized under standard

More information

www. ElectricalPartManuals. com MAGNETIC TIME RELAYS GENERAL. ELECTRIC INSTRUCTIONS *IC *Also identified with prefix CR instead of IC.

www. ElectricalPartManuals. com MAGNETIC TIME RELAYS GENERAL. ELECTRIC INSTRUCTIONS *IC *Also identified with prefix CR instead of IC. NSTRUCTONS MAGNETC TME RELAYS *C2820-054 *Also identified with prefix CR instead of C. GENERAL. ELECTRC GEH-85F NTRODUCTON The CR2820-054 relay is a d-e operated relay. t may be applied as an instantaneous

More information

ABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet

ABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet ABB Instruction Leaflet 41-137.2E Effective: February 1994 Supersedes I.L. 41-137.2D, Dated February 1973 ( )Denotes Change Since Previous Issue. Type KRV Directional Before putting relays into service,

More information

Figure 1. Type CWP-1 Ground Relay (Front View) Figure 2. Type CWP-1 Ground Relay (Rear View) E

Figure 1. Type CWP-1 Ground Relay (Front View) Figure 2. Type CWP-1 Ground Relay (Rear View) E Figure 1. Type CWP-1 Ground Relay (Front View) Figure 2. Type CWP-1 Ground Relay (Rear View) 41-242.5E 2 Typical 60 Hertz time product curves for the type CWP-1 relay are shown in Figure 4 with 100 volts

More information

ABB. Type CRQ Directional Negative Sequence Relay for Ground Protection B 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION CAUTION

ABB. Type CRQ Directional Negative Sequence Relay for Ground Protection B 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION CAUTION ABB Instruction Leaflet 41-163.2B Effective: January 1977 Supersedes I.L. 41-137.3A, Dated September 1974 ( ) Denotes Change Since Previous Issue Type CRQ Directional Negative Sequence Relay for Ground

More information

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Bussmann series Quik-Spec Power Module Switch elevator disconnect Supersedes January 2016 Agency information UL 98 enclosed and dead-front switch - Guide WIAX, WIAX7 (Canada), File E182262 culus, NEMA 1, UL 50, Listed enclosure cul per Canadian Standards C22.2, No. 0-M91-CAN/

More information

Circuit Protectors CP31F, 32F, 33F

Circuit Protectors CP31F, 32F, 33F CP3F, 32F, 33F CP-F slim type circuit protectors 20V AC/6V DC (-pole) 0.A to 30A 20V AC/2V DC (2-pole) 0.A to 30A 20V AC (3-pole) 0.A to 30A Description FUJI's compact and high-performance CP-F series

More information

2.2. Molded Case Circuit Breakers. Contents. NG-Frame ( Amperes) Series G

2.2. Molded Case Circuit Breakers. Contents. NG-Frame ( Amperes) Series G . NG-Frame (00 ) NG-Frame (30 00 s) Product All Eaton NG-Frame circuit breakers are suitable for reverse feed use All NG-Frame circuit breakers are HACR rated Contents Page EG-Frame (5 5 s)..................

More information

SERVICE PARTS MANUAL

SERVICE PARTS MANUAL SERVICE PARTS MANUAL 28V SERIES SNOW PLOWS FOR PLOW SERIAL NUMBERS AFTER 28VG100000 28VD100000 07 Sno-Way International 9710097F TABLE OF CONTENTS Page PARTS LIST INTRODUCTION... 2 POWER PACK FRAME...

More information

contactor may be required to interrupt up to 200% current. The N.O. contacts are equipped with permanent magnet blowouts to meet this requirement.

contactor may be required to interrupt up to 200% current. The N.O. contacts are equipped with permanent magnet blowouts to meet this requirement. DP Contactors DC Control DP Definite Purpose Contactors are designed for DC adjustable speed drive circuits using silicon controlled rectifier switching and other controls where a combination of normally

More information

Certi cation Record INDUSTRIAL CONTROL EQUIPMENT Motor Controllers Magnetic

Certi cation Record INDUSTRIAL CONTROL EQUIPMENT Motor Controllers Magnetic Certi cation Record Customer Schneider Electric USA, Inc. Square D Raleigh (Knightdale) Plant, 8001 Knightdale Blvd Knightdale NC USA 27545 Class 3211 04 INDUSTRIAL CONTROL EQUIPMENT Motor Controllers

More information

B CW POWER RELAY

B CW POWER RELAY 41-241.31B CW POWER RELAY nected in such a way that current, (I A ), leads voltage, (V BA ), by 150 degrees when the motor is operating at unity power factor. Loss of excitation to the motor causes a large

More information

ichards MANUFACTURING COMPANY, SALES, INC. 517 LYONS AVENUE, IRVINGTON, NJ Phone Fax

ichards MANUFACTURING COMPANY, SALES, INC. 517 LYONS AVENUE, IRVINGTON, NJ Phone Fax Network Protector Instruction Manual Type 147NP 2250 to 4500 Amperes ichards MANUFACTURING COMPANY, SALES, INC. 517 LYONS AVENUE, IRVINGTON, NJ 07111 Phone 973-371-1771 Fax 973-371-9538 IM 1225-001B DISCLAIMER

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and

More information

ABB Automation Inc. Substation Automation and Protection Division Coral Springs, FL 33065

ABB Automation Inc. Substation Automation and Protection Division Coral Springs, FL 33065 ABB Automation Inc. Substation Automation and Protection Division Coral Springs, FL 33065 Instruction Leaflet Effective: October 1999 Supersedes I.L. 41-133R, Dated August 1998 ( ) Denotes Changed Since

More information

SERVICE AND REPAIR PARTS NEMA SIZE 3, SINGLE POLE, NORMALLY OPEN, P/N SERIES NEMA SIZE 4, SINGLE POLE, NORMALLY OPEN, P/N SERIES

SERVICE AND REPAIR PARTS NEMA SIZE 3, SINGLE POLE, NORMALLY OPEN, P/N SERIES NEMA SIZE 4, SINGLE POLE, NORMALLY OPEN, P/N SERIES Hubbell Industrial Controls, Inc. Instructions 5210 SERVICE AND REPAIR PARTS NEMA SIZE 3, SINGLE POLE, NORMALLY OPEN, P/N 59364 SERIES NEMA SIZE 4, SINGLE POLE, NORMALLY OPEN, P/N 59345 SERIES Publication

More information

SERVICE AND REPAIR PARTS NEMA SIZE 5, SINGLE POLE, NORMALLY OPEN, P/N SERIES NEMA SIZE 5A, SINGLE POLE, NORMALLY OPEN, P/N SERIES

SERVICE AND REPAIR PARTS NEMA SIZE 5, SINGLE POLE, NORMALLY OPEN, P/N SERIES NEMA SIZE 5A, SINGLE POLE, NORMALLY OPEN, P/N SERIES Hubbell Industrial Controls, Inc. SERVICE AND REPAIR PARTS NEMA SIZE 5, SINGLE POLE, NORMALLY OPEN, P/N 59495 SERIES NEMA SIZE 5A, SINGLE POLE, NORMALLY OPEN, P/N 59675 SERIES Instructions 5210 Publication

More information

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION Medium Voltage Standby non-paralleling Control 1. GENERAL GUIDE FORM SPECIFICATION A. The requirements of the contract, Division 1, and part 16 apply to work in this section. 1.01 SECTIONS INCLUDE A. Medium

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that representative samples of Motor Controllers, Magnetic USL, CNL - Type No 3RT10, 3RT11,

More information

A Summary of Major Improvements to the ABB Recloser and Type R Breaker

A Summary of Major Improvements to the ABB Recloser and Type R Breaker A Summary of Major Improvements to the ABB Recloser and Type R Breaker Table of Contents Introduction....................................................................3 Center Bumper..................................................................4

More information

Enclosed Molded Case Circuit Breakers

Enclosed Molded Case Circuit Breakers Enclosed Motor Controllers and Molded Case Circuit Breakers KTA7 Type-E Self Protected Manual Motor Controllers Page 89 Explosion-Proof Motor Controllers KTA7_EX Page 9 The following pages contain a selection

More information

J lh. NEMA AC Contactors for Motor Loads (Bulletin 500) and Non-motor Loads (Bulletin 500L) Sizes 0 through 4 (all series), Size 5 (series L)

J lh. NEMA AC Contactors for Motor Loads (Bulletin 500) and Non-motor Loads (Bulletin 500L) Sizes 0 through 4 (all series), Size 5 (series L) e Roc~wM Automation Allen-Bradley NEMA AC Contactors for Motor Loads (Bulletin 500) and Non-motor Loads (Bulletin 500L) Sizes 0 through 4 (all series), Size 5 (series L) Renewal Parts Bulletin 500F - Size

More information

Cutler-Hammer. Installation Instructions for the Digitrip OPTIM Pole Trip Unit Installation and Operation with L-Frame Series C Circuit Breakers

Cutler-Hammer. Installation Instructions for the Digitrip OPTIM Pole Trip Unit Installation and Operation with L-Frame Series C Circuit Breakers Cutler-Hammer Installation Instructions for the Digitrip OPTIM 550 3-Pole Trip Unit Installation and Operation with L-Frame Series C Circuit Breakers Table of Contents Description Page 1.0 General Information......................1

More information

NEHB Circuit Breaker Panelboards. For 480Y /277V. ac Systems

NEHB Circuit Breaker Panelboards. For 480Y /277V. ac Systems NEHB Circuit Breaker Panelboards For 480Y /277V. ac Systems www. ElectricalPartManuals ElectricalPartManuals. com com NEHB Panelboards EHB (bolt-on) Circuit Breakers MONO-FLAT front features completely

More information

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics Miniature circuit breakers General information General information Miniature circuit breakers (MCBs) are used throughout the world in all types of electrical installations. ABB MCBs are recognized for

More information

section-page Table 1. Transfer switching device ratings. Conditional short circuit current

section-page Table 1. Transfer switching device ratings. Conditional short circuit current Operator s Manual 7000 Series ATS Automatic Transfer Switching Equipment D design 30 through 200 amperes TABLE OF CONTENTS section-page INSTALLATION... 1-1 Enclosures and Mounting... 1-1 Power Connections...

More information