Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Size: px
Start display at page:

Download "Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US"

Transcription

1 LH SECION Industrial Hydraulic Valves Directional Control, ressure Control, Sandwich, Subplates & Manifolds, ccessories

2 echnical Information General Description Series D61VW directional control valves are 5-chamber, pilot operated, solenoid controlled valves, hey are available in 2 or 3-position styles. hese valves are manifold or subplate mounted, and conform to NF s D08, CEO 8 mounting patterns. Operation Series D61VW pilot operated valves are standard with low shock spools and pilot orifice. he orifice can be removed if a faster shift is required. It is recommended, however, that all systems operating above 138 ar (2000 SI) use the standard valve to avoid severe shock. Features Low pressure drop design. Hardened spools provide long life. Fast response option available. Explosion proof availability. Wide variety of voltages and electrical connection options. No tools required for coil removal. Specifications Mounting attern Maximum Operating ressure Maximum ank Line ressure Maximum Drain ressure Minimum ilot ressure Maximum ilot ressure Nominal Flow Maximum Flow NF D08 CEO 8, NG ar (3000 SI) Standard CS 205 ar (3000 SI) Internal Drain Model: 102 ar (1500 SI) C Only 205 ar (3000 SI) DC Std./ C Optional External Drain Model: 205 ar (3000 SI) CS 102 ar (1500 SI) 102 ar (1500 SI) C Standard 205 ar (3000 SI) DC Standard/ C Optional CS 5.1 ar* (75 SI) 102 ar (1500 SI) 205 ar (3000 SI) Standard CS 205 ar (3000 SI) 189 LM (50 GM) See Reference Data Chart * 6.9 ar (100 SI) for spool configurations 002, 007, 008, 009 & 014. Series D61V Response ime Response times (milliseconds) are measured at 205 ar (3000 SI) and 195 LM (50 GM) with various pilot pressures as indicated. Solenoid ilot ull-in Drop-Out ype ressure Std Fast Std Fast DC C ecause of the high drain line pressure transients generated during shifting, use of the fast response option is not recommended for pilot pressures exceeding 138 ar (2000 SI). LH SECION D61.indd, dd 137 arker Hannifin Corporation Elyria, Ohio, US

3 Ordering Information D Directional Control Valve 61V Series D61V asic Valve ctuator Spool Style ilot Supply Seal Solenoid and Drain Voltage LH SECION Code 001 NF D08, CEO 8, DIN NG25 Low Flow, D03 ilot Code Description W* Solenoid, Wet in, Screw-in HW* Symbol Reversed Wiring * Valve schematic symbols are per NF/NSI standards, providing flow to when energizing solenoid. Note operators reverse sides for #008 and #009 spools. See installation information for details. o configure per DIN standards ( coil over port, coil over port) code valves as D61VHW***. Code 011 Symbol Code Code N V Description Description Nitrile Fluorocarbon 1 Internal ilot, External Drain 2 External ilot, External Drain 3** Internal ilot w/check, External Drain 4* Internal ilot, Internal Drain 5 External ilot, Internal Drain 6** Internal ilot w/check Internal Drain * Not availble with 002, 007, 008, 009 & 014 spools. ** #3 and #6 bodies cannot be converted to other styles. Other pilot versions cannot be converted to styles 3 and 6. Code Description * 24/50 VC D G J K N** 120 VDC 198 VDC 24 VDC 12 VDC 220/50 VC Q* 100/60 VC QD R U Y Z 100 VC/60 HZ 100 VC/50 HZ 24/60 VC 240/60-220/50 VC 98 VDC 120/60-110/50 VC 250 VDC * High Watt only. ** Explosion roof only. vailable in DIN only. Code Description Symbol * Single solenoid, 2 position, spring offset. to and to in offset position. C Double solenoid, 3 position, spring centered. b b a D* Double solenoid, 2 position, detent. b a * 009** * 008 spool has closed crossover. ** 009 spool has open crossover. E F** Single solenoid, 2 position, spring centered. to and to when energized. Single solenoid, 2 position, spring offset, energized to center. osition spool spacer on side. to and to in spring offset position. H* Single solenoid, 2 position, spring offset. to and to in offset position. K Single solenoid, 2 position, spring centered. to and to when energized. M** Single solenoid, 2 position, spring offset, energized to center position. Spool spacer on side. to and to in spring offset position. * vailable with 001, 002, 004, 011 and 014 spools only. ** High watt coil only. b b a a a D61.indd, dd old: Designates ier I products and options. Non-bold: Designates ier II products and options. hese products will have longer lead times. 138 arker Hannifin Corporation Elyria, Ohio, US

4 Ordering Information Solenoid Connection Code Description C* Leadwire Conduit ox D** Metric lug (M12X1), DESIN E Explosion roof G lug-in Conduit ox J# Deutsch (D06-2S) M# Metri-ack (150) DIN with lug S# Dual Spade W DIN w/o lug * No variations See lug-in. ** DC only, lights, diode surge suppressor, not CS approved. Not available with lights. Required for variations on conduit box style. Must have lights. # DC only, no lights, not CS approved. Coil Options Code Omit ube Options Series D61V Manual Override Options Code Description Omit Standard Extended with oot None DC or C Rectified only. Manual Override options not available with Explosion roof. Description Standard ressure ar (1500 SI) C 207 ar (3000 SI) DC H* High ressure, C only 207 ar (3000 SI) * Not available with CS. Electrical Options Shift Response and Indication pprovals Valve Variations See next page Design Series NOE: Not required when ordering. Code Description Omit Standard Valve 3* CS US 4*# CS pproved * Not available with C high pressure tube. # Valve is derated with this option., C, H styles only. J, K, Y, U voltages only with C, G, W solenoid connections only. Conforms to UL429. LH SECION Code Description Omit* High Watt D** Explosion roof, EEXD EX E** Explosion roof, EEXME EX F Low Watt L 10 Watt O** Explosion roof, MSH # Explosion roof, Ex d IIC EX/CS U** Explosion roof, UL/CS * C ambient temperature must not exceed 60 C (140 F). ** 60 Hz only on C, no options. C only. DC and C rectified only. # J, K and Y voltages only. Dual frequency on C, no options. Valve Weight: Double Solenoid Seal Kit: Nitrile Fluorocarbon 12.1 kg (26.6 lbs.) SKD61VWN91 SKD61VWV91 Code Description Omit No Options J* Diode Surge Suppressor Z Rectified Coil * DC only. DIN coil must include plug with lights. DC tube standard. Code Omit I3 I6 Note: Description Mounting olt Kits Standard Response, No Switch Monitor Switch, & ort End Monitor Switch, & ort Start Not CE or CS approved. Not available with F or M styles. UNC olt Kits for use with D6 and D8 & Sandwich Valves Number of Sandwich 2.75" (70mm) thickness D6 K227 K121 K122 K " 5.25" 8.00" 10.75" D6 plus K161 K170 K171 K172 tapping plate 3.50" 6.25" 9.00" 11.75" D8 K228 K131 K132 K " 5.75" 8.50" 11.25" D8 plus K173 K174 K175 K114 tapping plate 4.00" 6.75" 9.50" " D61.indd, dd old: Designates ier I products and options. Note: ll bolts are SE grade 8, 1/2-13 UNC-3 thread, torque to 133 N.m. (100 ft.-lbs.) Non-bold: Designates ier II products and options. hese products will have longer lead times. 139 arker Hannifin Corporation Elyria, Ohio, US

5 Ordering Information Valve Variations Code Description 5* Signal Lights Standard 7** Signal Lights Hirsch. (DIN with plug) Manaplug rad Harrison (12x1) Micro with lights 56** Manaplug (Mini) with Lights 20 Fast Response 1C** 1D** 1G** 1H** 1M** 1 1R 3 3 3C 3D 3E 3F Manaplug (Mini) Single Sol. 5-pin, with Lights Manaplug (Micro) Single Sol. 5-pin, with Lights Manaplug (Mini) Single Sol. 5-pin, with Stroke djust & End and Lights Manaplug (Micro) Single Sol. 5-pin, with Stroke djust & End and Lights Manaplug Opposite Normal ainted ody Stroke djust & End with ilot Choke Meter In ilot Choke Meter Out ilot Choke Meter In ilot ressure Reducer Stroke djust End Stroke djust End Stroke djust & End 3G* ilot Choke Meter Out with Lights 3H* ilot Choke Meter In with Lights 3J* ilot ressure Reducer with Lights 3K 3L** 3M 3R 3S** 7Y** ilot Choke Meter Out with Stroke djust & End ilot Choke Meter Out, Stroke djust & End with Lights and Manaplug rad Harrison Mini ilot Choke Meter Out, ilot ressure Reducer, Stroke djust & End ilot Choke Meter Out & ilot ressure Reducer Lights, Mini Manaplug, ilot Choke Meter Out M12x1 Manaplug (4-pin), Special Wiring, and Lights * DESIN, plug-in conduit box, and DIN with plug styles only. ** Must have plug-in style conduit box. Series D61V LH SECION D61.indd, dd 140 arker Hannifin Corporation Elyria, Ohio, US

6 echnical Information Reference Data Series D61V MaximumFlow, Maximum Flow, LM (GM) LM (GM) Spool 207 ar (3000 SI) Spool 207 ar (3000 SI) Model Symbol w/o Malfunction Model Symbol w/o Malfunction LH SECION D61V* (100) D61V* (80) D61V* (80) D61V* (80) D61V* (100) D61V* (100) D61V* (100) D61V* (35) D61V* (100) D61V* (50) D61V* (100) D61V* (100) D61V* (50) D61V* (100) D61V* Series ressure Drop Chart he following chart provides the flow vs. pressure drop curve reference for the Series D61V valves by spool type. VISCOSIY CORRECION FCOR Viscosity (SSU) % of (pprox.) Curves were generated using 100 SSU hydraulic oil. For any other viscosity, pressure drop will change as per chart. erformance Curves D61VW ressure Drop Reference Chart -- Curve Number Spool No / D61.indd, dd 141 arker Hannifin Corporation Elyria, Ohio, US

7 echnical Information Solenoid Ratings Insulation System llowable Deviation from rated voltage rmature CS File Number Environmental Capability Class F -15% to +10% for DC and C rectified coils -5% to +5% for C Coils Wet pin type LR60407 DC Solenoids meet NEM 4 and I67 when properly wired and installed. Contact HVD for C coil applications. Series D61V Explosion roof Solenoid Ratings* U.L. & CS (EU) Class I, Div 1 & 2, Groups C & D Class II, Div 1 & 2, Groups E, F & G s defined by the N.E.C. MSH (EO) Complies with 30CFR, art 18 EX (ED) EX & CS/US (E) Complies with EX requirements for: Exd, Group II; EN50014: mds. 1 & 2, EN50018: 2000 Complies with EX EN , EN Ex d IIC; CS/US Ex d IIC, Ex d IIC for Class I, Zone 1, UL1203, UL1604, CS E61241,1 Class II, Div 1 * llowable Voltage Deviation ±10%. Note that Explosion roof C coils are single frequency only. LH SECION Code Voltage In Rush mps In Rush Holding mps Watts Resistance Voltage ower mperage 3MM Code Code D L 120 VDC N/ N/ 0.09 mps 10 W ohms D Omit 120 VDC N/ N/ 0.26 mps 30 W ohms G Omit 198 VDC N/ N/ 0.15 mps 30 W ohms J L 24 VDC N/ N/ 0.44 mps 10 W ohms J Omit 24 VDC N/ N/ 1.32 mps 30 W ohms K L 12 VDC N/ N/ 0.88 mps 10 W ohms K Omit 12 VDC N/ N/ 2.64 mps 30 W 4.32 ohms L L 6 VDC N/ N/ 1.67 mps 10 W 3.59 ohms L Omit 6 VDC N/ N/ 5.00 mps 30 W 1.20 ohms Q Omit 100 VC / 60 Hz 2.05 mps 170 V 0.77 mps 30 W ohms QD F 100 VC / 60 Hz 1.35 mps 135 V 0.41 mps 18 W ohms QD F 100 VC / 50 Hz 1.50 mps 150 V 0.57 mps 24 W ohms R F 24/60 VC, Low Watt 6.67 mps 160 V 2.20 mps 23 W 1.52 ohms Omit 240/60 VC 0.83 mps 199 V 0.30 mps 30 W ohms Omit 220/50 VC 0.87 mps 191 V 0.34 mps 30 W ohms F 240/60 VC, Low Watt 0.70 mps 168 V 0.22 mps 21 W ohms F 220/50 VC, Low Watt 0.75 mps 165 V 0.26 mps 23 W ohms U L 98 VDC N/ N/ 0.10 mps 10 W ohms U Omit 98 VDC N/ N/ 0.31 mps 30W ohms Y Omit 120/60 VC 1.7 mps 204 V 0.60 mps 30 W ohms Y Omit 110/50 VC 1.7 mps 187 V 0.68 mps 30 W ohms Y F 120/60 VC, Low Watt 1.40 mps 168 V 0.42 mps 21 W ohms Y F 110/50 VC, Low Watt 1.50 mps 165 V 0.50 mps 23 W ohms Z L 250 VDC N/ N/ 0.04 mps 10 W ohms Z Omit 250 VDC N/ N/ 0.13 mps 30 W ohms Explosion roof Solenoids R 24/60 VC 7.63 mps 183 V 2.85 mps 27 W 1.99 ohms 240/60 VC 0.76 mps 183 V 0.29 mps 27 W 1.34 ohms N 220/50 VC 0.77 mps 169 V 0.31 mps 27 W 1.38 ohms Y 120/60 VC 1.60 mps 192 V 0.58 mps 27 W ohms 110/50 VC 1.47 mps 162 V 0.57 mps 27 W ohms K 12 VDC N/ N/ 2.75 mps 33 W 4.36 ohms J 24 VDC N/ N/ 1.38 mps 33 W ohms "E" Explosion roof Solenoids K 12 VDC N/ N/ 1.00 mps 12 W ohms J 24 VDC N/ N/ 1.00 mps 13 W ohms Y 120/60-50 VC N/ N/ 0.16 mps 17 W ohms D61.indd, dd 142 arker Hannifin Corporation Elyria, Ohio, US

8 Dimensions Inch equivalents for millimeter dimensions are shown in (**) lug-in Conduit ox, Double C Solenoid Series D61V LH SECION Note: 41.9mm (1.65") from bottom of bolt hole counterbore to bottom of valve. D61.indd, dd 143 arker Hannifin Corporation Elyria, Ohio, US

9 Dimensions Inch equivalents for millimeter dimensions are shown in (**) Series D61V lug-in Conduit ox and Stroke djust, Double C Solenoid LH SECION Note: 41.9mm (1.65") from bottom of bolt hole counterbore to bottom of valve. lug-in Conduit ox, Single C Solenoid Note: 41.9mm (1.65") from bottom of bolt hole counterbore to bottom of valve. D61.indd, dd 144 arker Hannifin Corporation Elyria, Ohio, US

10 Dimensions Inch equivalents for millimeter dimensions are shown in (**) lug-in Conduit ox, Double DC Solenoid Series D61V LH SECION Note: 41.9mm (1.65") from bottom of bolt hole counterbore to bottom of valve. D61.indd, dd 145 arker Hannifin Corporation Elyria, Ohio, US

11 Dimensions Inch equivalents for millimeter dimensions are shown in (**) Series D61V lug-in Conduit ox and Stroke djust, Double DC Solenoid LH SECION Note: 41.9mm (1.65") from bottom of bolt hole counterbore to bottom of valve. Hirschmann and ilot Choke Control, Double DC Solenoid lug-in Conduit ox, Single DC Solenoid D61.indd, dd 146 arker Hannifin Corporation Elyria, Ohio, US

12 Dimensions Inch equivalents for millimeter dimensions are shown in (**) lug-in Conduit ox, Double DC Solenoid with Variation I3 (Monitor Switch) Series D61V LH SECION Monitor Switch (Variation I3 and I6) his feature provides for electrical confirmation of the spool shift. his can be used in safety circuits, to assure proper sequencing, etc. Switch Data in 1 and in 3 have outputs equal to the input. When the monitor switch has the output to in 1, in 3 will have an output of zero, and vice-versa. When the valve is switched, in 1 and in 3 will switch outputs. IN 2 Input VDC osition Control Switch Sensor / Driver Circuitry Load 0.2 Max IN 1 IN 3 Outputs D61.indd, dd 147 arker Hannifin Corporation Elyria, Ohio, US

13 ccessories Manaplug (Options 6, 56, 1 & 1C) Interface rad Harrison lug 3-in for Single Solenoid 5-in for Double Solenoid Series D61V Micro Connector Options (7, 7, 1 & 1D) LH SECION Ground Wire #1 (Green) Solenoid (Negative) Wire #3 (Red/lack) Solenoid (ositive) Wire #2 (Red/White) 3-in Manaplug (Mini) with Lights Single Solenoid Valves Installed Opposite Side of Solenoid ins are as seen on valve (male pin connectors) Manaplug Electrical Mini lug E E E in lug 5 in lug (Double Solenoid) 5 in lug (Single Solenoid) Conduit ox Option C No Wiring Options vailable Manaplug Electrical Micro lug E E E in lug 5 in lug (Double Solenoid) 5 in lug (Single Solenoid) Signal Lights (Option 5) lug-in Only LED Interface Meets Nema 4/I67 Hirschmann lug with Lights (Option 5) ISO 4400/DIN Form D61.indd, dd in #2 (ositive) Face View of lug in #3 (Ground) in #1 (Negative) DESIN Connector (Option D) M12 pin assignment Standard 1 = Not used 2 = Not used 3 = 0V 4 = Signal (24 V) 5 = Earth Ground ins are as seen on valve (male pin connectors) DESIN design in 1 and 2 connected arker Hannifin Corporation Elyria, Ohio, US

14 echnical Information General Description Series D61V directional control valves are 5-chamber, air pilot operated valves. hey are available in 2 or 3-position styles. hese valves are manifold or subplate mounted, and conform to NF s D08, CEO 8 mounting patterns. Specifications Mounting attern Max. Operating ressure Max. ank ressure Max. Drain ressure Maximum Flow ilot ressure Response ime Ordering Information D Directional Control Valve D61.indd, dd NF D08 CEO 8 Code Symbol Code Symbol * 009** V asic Valve * 008 spool has closed crossover. ** 009 spool has open crossover. NF D08, CEO 8, NG ar (3000 SI) Internal Drain Model: 34 ar (500 SI) External Drain Model: 207 ar (3000 SI) 34 ar (500 SI) See Reference Data ir Min. 3.4 ar (50 SI) ir Max ar (150 SI) ir Operated ilot Valve schematic symbols are per NF/ NSI standards, providing flow to when energizing operator. Note operators reverse sides for #8 and #9 spools. See installation information for details. Varies with pilot line size and length, pilot pressure, pilot valve shift time & flow capacity (GM) Series D61V Features Spool Style ilot Supply Seal and Drain Low pressure drop. Fast response option available. Hardened spools provide long life. Valve Variations Code Description Code Description N Nitrile Omit Standard V Fluorocarbon 7 ilot Choke Meter-out Code Description 8 Stroke dj. End 1 Int. pilot/ext. drain 9 Stroke dj. End 2 Ext. pilot/ext. drain 60 ilot Choke Meter-in 4# Int. pilot/int. drain 89 Stroke dj. & Ends 5 Ext. pilot/int. drain 90 1/4 Shreads # Not available with 002, 008 & 009 spools. Code Description Symbol b Single operator, 2 position, spring offset. to and to in offset position. C D Double operator, 3 position, spring centered. Double operator, 2 position, detent. b b b a Design Series NOE: Not required when ordering. E Single operator, 2 position, spring offset to center. Valve Weight: 12.4 kg (27.3 lbs.) to and to in shifted position. a Standard olt Kit: K227 H Single operator, 2 position, spring offset. Metric olt Kit: KM227 to and to in offset position. Seal Kit: a K Single operator, 2 position. Spring offset to center. Nitrile SKD61V to and to in shifted position. Fluorocarbon SKD61VV old: Designates ier I products and options. Non-old: Designates ier II products and options. hese products will have longer lead times. a his condition varies with spool code. LH SECION 149 arker Hannifin Corporation Elyria, Ohio, US

15 Dimensions Inch equivalents for millimeter dimensions are shown in (**) Series D61V LH SECION Note: 41.9mm (1.65") from bottom of bolt hole counterbore to bottom of valve. D61.indd, dd 150 arker Hannifin Corporation Elyria, Ohio, US

16 echnical Information General Description Series D61VL directional control valves are 5-chamber, lever operated valves. hey are available in 2 and 3-position styles. hey are manifold or subplate mounted valves, which conform to NF s D08, CEO 8 mounting patterns. Specifications Series D61VL LH SECION Mounting attern NF D08, CEO 8, NG25 Max. Operating 207 ar (3000 SI) ressure Max. ank Internal Drain Model: ressure 34 ar (500 SI) External Drain Model: 207 ar (3000 SI) Maximum Drain 34 ar (500 SI) ressure Maximum Flow See Reference Data ilot Oil Min. 6.9 ar (100 SI) ressure Oil Max. 207 ar (3000 SI) Varies with pilot line size and Response ime length, pilot pressure, pilot valve shift time & flow capacity (GM) Ordering Information D Directional Control Valve NF D08 CEO 8 Code Symbol Code Symbol * 009** V asic Valve * 008 spool has closed crossover. ** 009 spool has open crossover. Valve schematic symbols are per NF/ NSI standards, providing flow to when energizing operator. Note operators reverse sides for #8 and #9 spools. See installation information for details. L Lever Operated ilot Features Spool Style ilot Supply Seal and Drain Low force required to shift spool. Hardened spools provide long life. Low pressure drop design. Code Description Code Description 1 Int. pilot/ext. drain N Nitrile 2 Ext. pilot/ext. drain V Fluorocarbon 4# Int. pilot/int. drain 5 Ext. pilot/int. drain # Not available with 002, 008 & 009 spools. Code Description * Single operator, 2 position, spring offset. to and to in offset position. C Double operator, 3 position, spring centered. D* Double operator, 2 position, detent. E Single operator, 2 position, spring centered. to and to in shifted position. H* Single operator, 2 position, spring offset. to and to in offset position. K Single operator, 2 position. Spring centered. to and to in shifted position. Symbol Valve Weight: 12.1 kg (26.7 lbs.) Standard olt Kit: K227 Metric olt Kit: KM227 Seal Kit: Nitrile SKD61VL * vailable with 001, 002, 004, 011, 012. Fluorocarbon SKD61VLV old: Designates ier I products and options. Non-old: Designates ier II products and options. hese products will have longer lead times. D61.indd, dd Valve Variations Code Description Omit Standard 7 ilot Choke Meter Out 8 Stroke dj. End 9 Stroke dj. End 60 ilot Choke Meter In 89 Stroke dj. & Ends Design Series NOE: Not required when ordering. his condition varies with spool code. 151 arker Hannifin Corporation Elyria, Ohio, US

17 Dimensions Inch equivalents for millimeter dimensions are shown in (**) Series D61VL LH SECION Note: 41.9mm (1.65") from bottom of bolt counterbore. D61.indd, dd 152 arker Hannifin Corporation Elyria, Ohio, US

18 echnical Information General Description Series D6 directional control valves are 5-chamber, pilot operated valves. hey are available in 2 or 3-position styles. hese valves are manifold or subplate mounted, and conform to NF s D08, CEO 8 mounting patterns. Features Low pressure drop design. Hardened spools provide long life. Fast response option available. Specifications Mounting attern NF D08, CEO 8, NG25 Max. Operating ress. 207 ar (3000 SI) Max. ank Line ress. 207 ar (3000 SI) Max. Drain ressure Min. ilot ressure Max. ilot ressure Nominal Flow Maximum Flow 207 ar (3000 SI) 5.1 ar* (75 SI) 207 ar (3000 SI) 189 Liters/Min (50 GM) See Reference Chart * 6.9 ar (100 SI) for 2, 8, 9 & 12 spools For flow path, pilot drain and pilot pressure details, see Installation Information. Ordering Information Series D6 Response ime Response time will vary with pilot line size, pilot line length, pilot pressure shift time and flow capacity of the control valve. Shift Volume he pilot chamber requires a volune of 0.54 in 3 for center to end and 1.08 in 3 for end to end. LH SECION D 6 Directional Control Valve Code Symbol Code Symbol * 8 spool has closed crossover. ** 9 spool has open crossover. Valve schematic symbols are per NF/NSI standards, providing flow to when energizing operator X. Note operators reverse sides for #8 and #9 spools. See installation information for details. D61.indd, dd 1 8* 9** asic Valve NF D08 CEO 8 Hydraulic ilot Valve Weight: 11.0 kg (24.2 lbs.) Standard olt Kit: K227 Metric olt Kit: KM227 Spool Style ilot Supply Seal and Drain Code N V ype Nitrile Fluorocarbon Code Description 2 Ext. ilot Ext. Drain 5# Ext. ilot Int. Drain # vailable in & H styles only. Code Description Symbol C H Single operator, 2 position, spring offset. to and to in offset position. Double operator, 3 position, spring centered. Single operator, 2 position, spring offset. to and to in offset position. Valve Variations Design Series NOE: Not required when ordering. Code Description Omit Standard 7 ilot Choke Meter Out 8 Stroke dj. End 9 Stroke dj. End 20 Fast Response 60 ilot Choke Meter In 89 Stroke dj. & Ends old: Designates ier I products and options. Non-old: Designates ier II products and options. hese products will have longer lead times. his condition varies with spool code. 153 arker Hannifin Corporation Elyria, Ohio, US

19 Dimensions Inch equivalents for millimeter dimensions are shown in (**) Standard ilot Operated Series D6 LH SECION ilot Operated with ilot Choke Control Note: 41.9mm (1.65") from bottom of bolt hole counterbore to bottom of valve. ilot Choke Control Variation (1.56) (7.23) Note: 41.9mm (1.65") from bottom of bolt hole counterbore to bottom of valve. D61.indd, dd 154 arker Hannifin Corporation Elyria, Ohio, US

20 Installation Information FOR MXIMUM VLVE RELIILIY, DHERE O HE FOLLOWING INSLLION INFORMION. he following is important installation information which applies to all directional control valves described in this catalog. Mounting osition Detent Horizontal Spring Offset Unrestricted Spring Centered Unrestricted Fluid Recommendations remium quality hydraulic oil with a viscosity range between cst. ( SSU ) t 38 C (100 F) is recommended. he absolute operating viscosity range is from cst. ( SSU). Oil should have maximum anti-wear properties and rust and oxidation treatment. Fluids and Seals Valves using synthetic, fire-resistant fluids require special seals. When phosphate esters or its blends are used, FLUOROCRON seals are required. Waterglycol, water-in-oil emulsions and petroleum oil may be used with SNDRD seals. Series D61V, D6 Silting Silting can cause any sliding spool valve to stick and not spring return if held under pressure for long periods of time. he valve should be cycled periodically to prevent sticking. Special Installations Consult your arker representative for any application requiring the following: ressure above rating. Fluid other than those specified. Oil temperature above 71.1 C (160 F). Flow path other than normal. Mounting atterns Series NF Size D61V*, D6 D08, CEO 8 3/4 orque Specifications he recommended torque values for the bolts which mount the valve to the manifold or subplate are as follows: Nm (100 ft-lbs). LH SECION Filtration For maximum valve and system component life, the system should be protected from contamination at a level not to exceed 125 particles greater than 10 microns per milliliter of fluid (SE class 4/ISO 16/13). D61.indd, dd 155 arker Hannifin Corporation Elyria, Ohio, US

21 Installation Information Series D61VW, D61V, D61VL ank and Drain Line Surges If several valves are piped with a common tank or drain line, flow surges in the line may cause an unexpected spool shift. Detent style valves are most susceptible to this. Separate tank and drain lines should be piped in installations where line surges are expected. Electrical Characteristics (Detented Spool) Only a momentary energizing of the solenoid is necessary to shift and hold a detented spool. Minimum duration of the signal is 0.1 seconds for DC voltages. For C voltages the response time is 0.06 seconds. Spool position will be held provided the spool centerline is in a horizontal plane, and not shock or vibration is present to displace the spool. Electrical Failure or Loss of ilot ressure (D61V) Should electric power fail or loss of pilot pressure occur, spring offset and spring centered valves will shift to the spring held position. Detented valves will stay in the last position held before power failure. If main flow does not fail or stop at the same time power fails, machine actuators may continue to function in an undesirable manner or sequence. ilot/drain Characteristics ilot ressure: 5.1 to 207 ar (75 to 3000 SI) 6.9 ar (100 SI) for spools 002, 007, 008, 009 & 014 External: n oil source sufficient to maintain minimum pilot pressure must be connected to the X port of the main body. When using the external pilot variation, a 1/16" pipe plug must be present in the main body pilot passage. (For details see Dimension pages.) his plug will be furnished in valves ordered with pilot code 2, 3, 5 or 6. Series D61V Internal: Flow is internally ported from the pressure port of the main valve body to the port of the pilot valve. he pressure developed at the port of the pilot valve must be 5.1 ar (75 SI) minimum at all times or 6.9 ar (100 SI) for spools 002, 007, 008, 009 & 014. Integral Check: Valves using internal pilot and internal drain with an open center spool (spools 002, 008 & 009) can be ordered with an integral check valve in the pressure port of the main valve codes 3 & 6. ilot oil will be internally ported from the upstream side of this check to the port of the pilot valve, ensuring sufficient pilot pressure. 1/16 pipe plug will be present in the main body. he X port in the subplate must be plugged when using the integral check. ilot Valve Drain: Maximum pressure 102 ar (1500 SI), 207 ar (3000 SI) optional. External: When using an external drain, a 10 x 24 x 0.31 long set screw must be present in the main body drain passage. (For details see Dimension pages.) his plug will be furnished in valves ordered with drain code 1, 2 or 3. Drain flow from the pilot valve is at the Y port of the main body and must be piped directly to tank. Maximum drain line pressure is 102 ar (1500 SI), 207 ar (3000 SI) optional. ny drain line back pressure is additive to the pilot pressure requirement. Internal: Drain flow from the pilot valve is internally connected to the main valve tank port. ank and drain pressure are then identical so tank line pressure should not exceed 102 ar (1500 SI), 207 ar (3000 SI) optional. ny tank line back pressure is also additive to the pilot pressure requirement. If flow surges (a cause of pressure surges) are anticipated in the tank line, an external drain variation is recommended. he Y port in the subplate must be plugged when using an internal drain. LH SECION D61V* Flow aths Style No Solenoid/Operator Solenoid/Operator Solenoid/Operator Code Description Energized Energized Energized Spring Offset and and C Spring Centered Centered and and D Detented Last osition Held and and E Spring Centered Centered and F Spring Offset, Shift to Center and Centered H Spring Offset and and K Spring Centered Centered and M Spring Offset, Shift to Center and Centered D61VW only. D61.indd, dd 156 arker Hannifin Corporation Elyria, Ohio, US

22 Installation Information Series D6 ank and Drain Line Surges If several valves are piped with a common tank or drain line, flow surges in the line may cause an unexpected spool shift. Detent style valves are most susceptible to this. Separate tank and drain lines should be piped in installations where line surges are expected. Loss of ilot ressure Should a loss of pilot pressure occur, spring offset and spring centered valves will shift to the spring held position. No spring valves will stay in the last position held. If main hydraulic flow does simultaneously stop, machine actuators may continue to function in an undesirable manner or sequence. Series D6 ilot Drain Characteristics ilot ressure: 5.1 to 207 ar (75 to 3000 SI) 6.9 ar (100 SI) for spools 2, 8, 9 & 12 Direct pilot operated valves use the X and Y ports to supply pilot oil directly to the ends of the spool, providing spool shifting force. block mounted on top of the valve body is internally cored to make the necessary connections. hus when X is pressurized, Y is used as a drain; and when Y is pressurized, X becomes the drain. ny back pressure in these lines when they are being used as a drain is additive to the pilot pressure requirement. Internal Drain: On spring offset models, only the X port is pressurized, as the spring returns the spool to its at rest position. On these models, Y may be internally drained through the main tank passage in the valve. LH SECION Flow ath/ilot ressure Style Code Recommended Description X & Y X ort Y ort Special Notes Control Valve De-ressurized ressurized ressurized For ilot Oil wo osition X ort may be pressurized to Spring Offset,,, assist spring in returning spool to offset position (ext. only) hree osition Flow paths will be reversed on C Spring Centered Center,, valves with tandem center (8) spools wo-osition Y ort may be pressurized H Spring Offset,,, to assist spring in returning spool to offset position D61.indd, dd 157 arker Hannifin Corporation Elyria, Ohio, US

23 Installation Information Subplate Mounting NF D08, CEO 8 & NG 25 Recommended Mounting Surface Surface must be flat within.102 mm ( inch).i.r and smooth within micro-meters (32 micro-inch). orque bolts to Nm (100 ft-lbs). Mounting osition Valve ype Detent (Solenoid) Spring Offset Spring Centered Mounting osition Horizontal Unrestricted Unrestricted Series D61V, D6 For maximum valve reliability, adhere to the following installation information. LH SECION Mounting attern NF D08, CEO 8 & NG 25 Inch equivalents for millimeter dimensions are shown in (**) (6.00) (5.13) (3.97) (4.44) 94.5 (3.72) (0.69) 4.8 (0.19) 77.0 (3.03) 29.4 (1.16) 53.2 (2.09) 17.5 (0.69) ½ 13 UNC 2x22.22 min th'd dp. (M12 x0.875) 6 holes 0.28 S (0.011) (5.12) 92.1 (3.63) (2.94) 73.0 (2.88) O11.2 (0.441) max. 3 holes 0.56 L (0.022) O (0.922) max. 4 holes 0.56 L (0.022) O /.272 x0.31 min dp. (7.32 / 6.91 x 8) 2 holes 0.28 L (0.011) D61.indd, dd 158 arker Hannifin Corporation Elyria, Ohio, US

24 Notes LH SECION D61.indd, dd 159 arker Hannifin Corporation Elyria, Ohio, US

25 Introduction pplication Series D81 hydraulic directional control valves are high performance, solenoid controlled, pilot operated, 2-stage, 4-way valves. hey are available in 2 or 3-position styles and are manifold mounted. hese valves conform to NF s D08, CEO 8 mounting pattern. Operation Series D81 directional valves consist of a 5-chamber style main body, a case hardened sliding spool, and a pilot valve or pilot operators (hydraulic or pneumatic). Series D81 Features Easy access mounting bolts. 345 ar (5000 SI) pressure rating. Flows to 622 LM (160 GM) depending on spool. Choice of four operator styles. Rugged four land spools. Low pressure drop. hosphate finish. LH SECION D81VW Solenoid Operated lug-in Conduit ox D81VL Lever Operated D8 Oil ilot Operated D81V ir ilot Operated D81.indd, dd 160 arker Hannifin Corporation Elyria, Ohio, US

26 echnical Information General Description Series D81VW directional control valves are 5-chamber, pilot operated, solenoid controlled valves. hey are available in 2 or 3-position styles. hese valves are manifold or subplate mounted, and conform to NF s D08, CEO 8 mounting pattern. Operation Series D81VW pilot operated valves are standard with low shock spools and pilot orifice. he orifice can be removed if a faster shift is required. It is recommended, however, that all systems operating above 138 ar (2000 SI) use the standard valve to avoid severe shock. Features Low pressure drop design. Hardened spools provide long life. Fast response option available. Wide variety of voltages and electrical connection options. Explosion proof availability. No tools required for coil removal. Response Specifications Mounting attern NF D08, CEO 8, NG25 Maximum Operating 345 ar (5000 SI) Standard ressure 207 ar (3000 SI) 10 Watt Maximum ank Line ressure Maximum Drain ressure Minimum ilot ressure Maximum ilot ressure Nominal Flow CS 207 ar (3000 SI) Internal Drain Model: 103 ar (1500 SI) C Only 207 ar (3000 SI) DC Std., C Optional External Drain Model: 345 ar (5000 SI) CS 103 ar (1500 SI) 103 ar (1500 SI) C Only 207 ar (3000 SI) DC Std., C Optional CS 103 ar (1500 SI) 5.1 ar* (75 SI) 345 ar (5000 SI) Standard CS 207 ar (3000 SI) 302 LM (80 GM) * 6.9 ar (100 SI) for spool configurations 002, 007, 008, 009 & 014. Series D81V ime Response times (milliseconds) are measured at 345 ar (5000 SI) and 300 LM (80 GM) with various pilot pressures as indicated. Solenoid ilot ull-in Drop-Out ype ressure Std Fast Std Fast DC C ecause of the high drain line pressure transients generated during shifting, use of the fast response option is not recommended for pilot pressures exceeding 138 ar (2000 SI). LH SECION D81.indd, dd 161 arker Hannifin Corporation Elyria, Ohio, US

27 Ordering Information D Directional Control Valve D81.indd, dd 81V Series D81V asic Valve ctuator Spool Style ilot Supply Seal Solenoid and Drain Voltage NF D08 CEO 8 DIN NG25 High Flow, D03 ilot Code Description W* Solenoid, Wet in, Screw-in HW* Reversed Wiring * Valve schematic symbols are per NF/ NSI standards, providing flow to when energizing solenoid. Note operators reverse sides for #008 and #009 spools. See installation information for details. o configure per DIN standards ( coil over port, coil over port) code valves as D81VHW***. Code * 009** 011 Symbol Code * 030** * 008 & 020 spool have closed crossover. ** 009 & 030 spool have open crossover. Symbol Code N V Description Nitrile Fluorocarbon Code Description * 24/50 VC D G J K N** 120 VDC 198 VDC 24 VDC 12 VDC 220/50 VC Q* 100/60 VC QD R U Y Z 100 VC/60 Hz 100 VC/50 Hz 24/60 VC 240/60-220/50 VC 98 VDC 120/60-110/50 VC 250 VDC * High Watt Coil only. ** Explosion roof only. vailable in DIN only. Code Description Symbol * Single solenoid, 2 position, spring offset. to and to in offset position. C Double solenoid, 3 position, spring centered. D* Double solenoid, 2 position, detent. E F** Single solenoid, 2 position, spring centered. to and to when energized. Single solenoid, 2 position, spring offset, energized to center. osition spool spacer on side. to and to in spring offset position. H* Single solenoid, 2 position, spring offset. to and to in offset position. K M** Code Description 1 Internal ilot, External Drain 2 External ilot, External Drain 3 Internal ilot w/check, External Drain 4* Internal ilot, Internal Drain 5 External ilot, Internal Drain 6 Internal ilot w/check, Internal Drain * Not availble with 002, 007, 008, 009, 014 & 030 spools. Single solenoid, 2 position, spring centered. to and to when energized. Single solenoid, 2 position, spring offset, energized to center position. Spool spacer on side. to and to in spring offset position. * vailable with 020 and 030 spools only. ** High watt coil only. old: Designates ier I products and options. Non-bold: Designates ier II products and options. hese products will have longer lead times. b b b b b a a a a a LH SECION 162 arker Hannifin Corporation Elyria, Ohio, US

28 Ordering Information Solenoid Connection Code Description C* Leadwire Conduit ox D** Metric lug (M12X1), DESIN E Explosion roof G lug-in Conduit ox J# Deutsch (D06-2S) M# Metri-ack (150) DIN with lug S# Dual Spade W DIN w/o lug * No variations See lug-in. ** DC only, lights, diode surge suppressor, not CS approved. Not available with lights. Required for variations on conduit box style. Must have lights. # DC only, no lights, not CS approved. Coil Options Code Description Omit* High Watt D** Explosion roof, EEXD EX E** Explosion roof, EEXME EX F Low Watt L 10 Watt O** Explosion roof, MSH # Explosion roof, Ex d IIC EX/CS U** Explosion roof, UL/CS * C ambient temperature must not exceed 60 C (140 F). ** 60 Hz only on C, no options. C only. DC and C rectified only. # J, K and Y voltages only. Dual frequency on C, no options. ube Options Code Omit Manual Override Options Series D81V Electrical Options Code Omit I3 I6 Note: Code Description Omit No Options J* Diode Surge Suppressor Z Rectified Coil * DC only. DIN coil must include plug with lights. DC tube standard. Code Description Omit Standard Extended with oot None DC or C Rectified only. Manual Override options not available with Explosion roof. Description Standard ressure 103 ar (1500 SI) C 207 ar (3000 SI) DC H* High ressure, C only 207 ar (3000 SI) * Not available with CS. Shift Response and Indication Description Standard Response, No Switch Monitor Switch, & ort End Monitor Switch, & ort Start Not CE or CS approved. Not available with F or M styles. Valve Weight: Double Solenoid Seal Kit: Nitrile Fluorocarbon pprovals Mounting olt Kits Valve Variations See next page Code Description Omit Standard Valve 3* CS US 4*# CS pproved * Not available with C high pressure tube. # Valve is derated with this option., C, H styles only. J, K, Y, U voltages only with C, G, W solenoid connections only. Conforms to UL kg (43.2 lbs.) SKD81VWN91 SKD81VWV91 Design Series NOE: Not required when ordering. UNC olt Kits for use with D6 and D8 & Sandwich Valves Number of Sandwich 2.75" (70mm) thickness D6 K227 K121 K122 K " 5.25" 8.00" 10.75" D6 plus K161 K170 K171 K172 tapping plate 3.50" 6.25" 9.00" 11.75" D8 K228 K131 K132 K " 5.75" 8.50" 11.25" D8 plus K173 K174 K175 K114 tapping plate 4.00" 6.75" 9.50" " Note: ll bolts are SE grade 8, 1/2-13 UNC-3 thread, torque to 133 N.m. (100 ft.-lbs.) LH SECION D81.indd, dd old: Designates ier I products and options. Non-bold: Designates ier II products and options. hese products will have longer lead times. 163 arker Hannifin Corporation Elyria, Ohio, US

29 Ordering Information Valve Variations Code Description 5* Signal Lights Standard 7** Signal Lights Hirsch. (DIN with lug) Manaplug rad Harrison (12x1) Micro with Lights 56** Manaplug (Mini) with Lights 20 Fast Response 1C** 1D** 1G** 1H** 1M** 1 1R 3 3 3C 3D 3E 3F Manaplug (Mini) Single Sol. 5-pin, with Lights Manaplug (Micro) Single Sol. 5-pin, with Lights Manaplug (Mini) Single Sol. 5-pin, with Stroke djust & End and Lights Manaplug (Micro) Single Sol. 5-pin, with Stroke djust & End and Lights Manaplug Opposite Normal ainted ody Stroke djust & End with ilot Choke Meter In ilot Choke Meter Out ilot Choke Meter In ilot ressure Reducer Stroke djust End Stroke djust End Stroke djust & End 3G* ilot Choke Meter Out with Lights 3H* ilot Choke Meter In with Lights 3J* ilot ressure Reducer with Lights 3K 3L** 3M 3R 3S** 7Y** ilot Choke Meter Out with Stroke djust & End ilot Choke Meter Out, Stroke djust & End with Lights and Manaplug rad Harrison Mini ilot Choke Meter Out, ilot ressure Reducer, Stroke djust & End ilot Choke Meter Out & ilot ressure Reducer Lights, Mini Manaplug, ilot Choke Meter Out M12x1 Manaplug (4-pin), Special Wiring, and Lights * DESIN, plug-in conduit box, and DIN with plug styles only. ** Must have plug-in style conduit box. Series D81V LH SECION D81.indd, dd 164 arker Hannifin Corporation Elyria, Ohio, US

30 echnical Information Reference Data Series D81V MaximumFlow, Maximum Flow, LM (GM) LM (GM) Spool 345 ar (5000 SI) Spool 345 ar (5000 SI) Model Symbol w/o Malfunction Model Symbol w/o Malfunction LH SECION D81V* (160) D81V*008 D81V* (80) D81V* (160) D81V* (160) D81V* (160) D81V* (80) D81V* (160) D81V* (80) D81V* (160) D81V* (160) D81V* (160) D81V* (160) D81V* (80) D81V*020 D81V* (160) D81V* Series ressure Drop Chart he following chart provides the flow vs. pressure drop curve reference for the Series D81V* valve by spool type. VISCOSIY CORRECION FCOR Viscosity (SSU) % of (pprox.) Curves were generated using 100 SSU hydraulic oil. For any other viscosity, pressure drop will change as per chart. erformance Curves D81VW ressure Drop Reference Chart Curve Number Spool No / D81.indd, dd 165 arker Hannifin Corporation Elyria, Ohio, US

31 echnical Information Solenoid Ratings Insulation System llowable Deviation from rated voltage rmature CS File Number Environmental Capability Class F -15% to +10% for DC and C rectified coils -5% to +5% for C Coils Wet pin type LR60407 DC Solenoids meet NEM 4 and I67 when properly wired and installed. Contact HVD for C coil applications. Series D81V Explosion roof Solenoid Ratings* U.L. & CS (EU) Class I, Div 1 & 2, Groups C & D Class II, Div 1 & 2, Groups E, F & G s defined by the N.E.C. MSH (EO) Complies with 30CFR, art 18 EX (ED) EX & CS/US (E) Complies with EX requirements for: Exd, Group II; EN50014: mds. 1 & 2, EN50018: 2000 Complies with EX EN , EN Ex d IIC; CS/US Ex d IIC, Ex d IIC for Class I, Zone 1, UL1203, UL1604, CS E61241,1 Class II, Div 1 * llowable Voltage Deviation ±10%. Note that Explosion roof C coils are single frequency only. LH SECION Code Voltage In Rush mps In Rush Holding mps Watts Resistance Voltage ower mperage 3MM Code Code D L 120 VDC N/ N/ 0.09 mps 10 W ohms D Omit 120 VDC N/ N/ 0.26 mps 30 W ohms G Omit 198 VDC N/ N/ 0.15 mps 30 W ohms J L 24 VDC N/ N/ 0.44 mps 10 W ohms J Omit 24 VDC N/ N/ 1.32 mps 30 W ohms K L 12 VDC N/ N/ 0.88 mps 10 W ohms K Omit 12 VDC N/ N/ 2.64 mps 30 W 4.32 ohms L L 6 VDC N/ N/ 1.67 mps 10 W 3.59 ohms L Omit 6 VDC N/ N/ 5.00 mps 30 W 1.20 ohms Q Omit 100 VC / 60 Hz 2.05 mps 170 V 0.77 mps 30 W ohms QD F 100 VC / 60 Hz 1.35 mps 135 V 0.41 mps 18 W ohms QD F 100 VC / 50 Hz 1.50 mps 150 V 0.57 mps 24 W ohms R F 24/60 VC, Low Watt 6.67 mps 160 V 2.20 mps 23 W 1.52 ohms Omit 240/60 VC 0.83 mps 199 V 0.30 mps 30 W ohms Omit 220/50 VC 0.87 mps 191 V 0.34 mps 30 W ohms F 240/60 VC, Low Watt 0.70 mps 168 V 0.22 mps 21 W ohms F 220/50 VC, Low Watt 0.75 mps 165 V 0.26 mps 23 W ohms U L 98 VDC N/ N/ 0.10 mps 10 W ohms U Omit 98 VDC N/ N/ 0.31 mps 30W ohms Y Omit 120/60 VC 1.7 mps 204 V 0.60 mps 30 W ohms Y Omit 110/50 VC 1.7 mps 187 V 0.68 mps 30 W ohms Y F 120/60 VC, Low Watt 1.40 mps 168 V 0.42 mps 21 W ohms Y F 110/50 VC, Low Watt 1.50 mps 165 V 0.50 mps 23 W ohms Z L 250 VDC N/ N/ 0.04 mps 10 W ohms Z Omit 250 VDC N/ N/ 0.13 mps 30 W ohms Explosion roof Solenoids R 24/60 VC 7.63 mps 183 V 2.85 mps 27 W 1.99 ohms 240/60 VC 0.76 mps 183 V 0.29 mps 27 W 1.34 ohms N 220/50 VC 0.77 mps 169 V 0.31 mps 27 W 1.38 ohms Y 120/60 VC 1.60 mps 192 V 0.58 mps 27 W ohms 110/50 VC 1.47 mps 162 V 0.57 mps 27 W ohms K 12 VDC N/ N/ 2.75 mps 33 W 4.36 ohms J 24 VDC N/ N/ 1.38 mps 33 W ohms "E" Explosion roof Solenoids K 12 VDC N/ N/ 1.00 mps 12 W ohms J 24 VDC N/ N/ 1.00 mps 13 W ohms Y 120/60-50 VC N/ N/ 0.16 mps 17 W ohms D81.indd, dd 166 arker Hannifin Corporation Elyria, Ohio, US

32 Dimensions Inch equivalents for millimeter dimensions are shown in (**) lug-in Conduit ox, Double C Solenoid Series D81V LH SECION 1/16 lug forvariations 2 & 5 orque to: ±1.67 Nm (105 ±15 in-lbs) Do Not Loctite M6 x 1 lug forvariations 1, 2 & 3 orque to: 1.78 ±0.22 Nm (16 ±2 in-lbs) Do Not Loctite Note: 57mm (2.24") from bottom of bolt hole counterbore to bottom of valve. D81.indd, dd 167 arker Hannifin Corporation Elyria, Ohio, US

33 Dimensions Inch equivalents for millimeter dimensions are shown in (**) Conduit ox and Stroke djust, Double C Solenoid Series D81V LH SECION Note: 57mm (2.24") from bottom of bolt hole counterbore to bottom of valve. Conduit ox and ilot Choke Control, Double C Solenoid Conduit ox, Single C Solenoid D81.indd, dd 168 arker Hannifin Corporation Elyria, Ohio, US

34 Dimensions Inch equivalents for millimeter dimensions are shown in (**) lug-in Conduit ox, Double DC Solenoid Series D81V LH SECION Note: 57mm (2.24") from bottom of bolt hole counterbore to bottom of valve. D81.indd, dd 169 arker Hannifin Corporation Elyria, Ohio, US

35 Dimensions Inch equivalents for millimeter dimensions are shown in (**) Series D81V lug-in Conduit ox and Stroke djust, Double DC Solenoid LH SECION Note: 57mm (2.24") from bottom of bolt hole counterbore to bottom of valve. Hirschmann and ilot Choke Control, Double DC Solenoid lug-in Conduit ox, Single DC Solenoid D81.indd, dd 170 arker Hannifin Corporation Elyria, Ohio, US

36 Dimensions Inch equivalents for millimeter dimensions are shown in (**) lug-in Conduit ox, Double C Solenoid with Variation I3 (Monitor Switch) Series D81V LH SECION Monitor Switch (Variation I3 and I6) his feature provides for electrical confirmation of the spool shift. his can be used in safety circuits, to assure proper sequencing, etc. Switch Data in 1 and in 3 have outputs equal to the input. When the monitor switch has the output to in 1, in 3 will have an output of zero, and vice-versa. When the valve is switched, in 1 and in 3 will switch outputs. IN 2 Input VDC osition Control Switch Sensor / Driver Circuitry Load 0.2 Max IN 1 IN 3 Outputs D81.indd, dd 171 arker Hannifin Corporation Elyria, Ohio, US

37 ccessories Manaplug (Options 56 & 1C) Interface rad Harrison lug 3-in for Single Solenoid 5-in for Double Solenoid Series D81V Micro Connector Options (7 & 1D) LH SECION Ground Wire #1 (Green) Solenoid (Negative) Wire #3 (Red/lack) Solenoid (ositive) Wire #2 (Red/White) 3-in Manaplug (Mini) with Lights Single Solenoid Valves Installed Opposite Side of Solenoid ins are as seen on valve (male pin connectors) Conduit ox Option C No Wiring Options vailable Signal Lights (Option 5) lug-in Only LED Interface Meets Nema 4/I67 Hirschmann lug with Lights (Option 5) ISO 4400/DIN Form D81.indd, dd in #2 (ositive) Face View of lug in #3 (Ground) in #1 (Negative) DESIN Connector (Option D) M12 pin assignment Standard 1 = Not used 2 = Not used 3 = 0V 4 = Signal (24 V) 5 = Earth Ground ins are as seen on valve (male pin connectors) DESIN design in 1 and 2 connected arker Hannifin Corporation Elyria, Ohio, US

38 echnical Information General Description Series D81V directional control valves are 5-chamber, air pilot operated valves. hey are available in 2 or 3-position styles. hese valves are manifold or subplate mounted, and conform to NF s D08, CEO 8 mounting pattern. Specifications Mounting attern NF D08, CEO 8, NG25 Max. Operating ressure Max. ank Line ressure Max. Drain ressure Maximum Flow ilot ressure Response ime Ordering Information D Directional Control Valve D81.indd, dd NF D08 CEO 8 DIN NG25 Code Symbol Code Symbol * 009** 030** 81V asic Valve 345 ar (5000 SI) * 020 spool has closed crossover. ** 009 & 030 spools have open crossover. Internal Drain Model: 34 ar (500 SI) External Drain Model: 207 ar (3000 SI) 34 ar (500 SI) See Switching Limit Charts ir Min 3.4 ar (50 SI) ir Max 10.2 ar (150 SI) Varies with pilot line size and length, pilot pressure, pilot valve shift time & flow capacity (GM) Valve schematic symbols are per NF/NSI standards, providing flow to when energizing operator. Note operators reverse sides for #9 spool. See installation information for details. Valve Weight: Single Operated 19.9 kg (43.9 lbs.) Standard olt Kit: K228 Metric olt Kit: KM228 ir Operated ilot Series D81V Features Low pressure drop design. Fast response option available. Hardened spools provide long life. Spool Style ilot Supply Seal Valve and Drain Variations Code Description N Nitrile V Fluorocarbon Code Description 1 Int. pilot/ext. drain 2 Ext. pilot/ext. drain 4# Int. pilot/int. drain 5 Ext. pilot/int. drain # Not available with 002, 008, 009 & 030 spools. Code Description Symbol Sgl. operator, 2 position, spring offset. to and to in offset position. C Dbl. operator, 3 position, spring centered. D Dbl. operator, 2 position, detent. E Sgl. operator, 2 position, spring centered. to and to when energized. H Sgl. operator, 2 position, spring offset. to and to in offset position. K Sgl. operator, 2 position. Spring centered. to and to when energized. vailable with 020 & 030 spools only. Code Description Omit Standard 7 ilot Choke Meter Out 8 Stroke dj. End 9 Stroke dj. End 60 ilot Choke Meter In 89 Stroke dj. & Ends 90 1/4 Shreads b b b b a a a Design Series NOE: Not required when ordering. his condition varies with spool code. old: Designates ier I products and options. Non-bold: Designates ier II products and options. hese products will have longer lead times. LH SECION 173 arker Hannifin Corporation Elyria, Ohio, US

39 Dimensions Inch equivalents for millimeter dimensions are shown in (**) ir Operated Series D81V LH SECION Note: 57mm (2.24") from bottom of bolt hole counterbore to bottom of valve. D81.indd, dd 174 arker Hannifin Corporation Elyria, Ohio, US

40 echnical Information General Description Series D81VL directional control valves are 5-chamber, lever operated valves. hey are available in 2 or 3-position styles. hese valves are manifold or subplate mounted, and conform to NF s D08, CEO 8 mounting pattern. Specifications Mounting attern NF D08, CEO 8, NG25 Max. Operating 350 ar (5000 SI) ressure Max. ank Line Internal Drain Model ressure 34 ar (500 SI) External Drain Model 350 ar (5000 SI) Maximum Drain 34 ar (500 SI) ressure Maximum Flow See Reference Data Charts ilot Oil Min 6.9 ar (100 SI) ressure Oil Max 350 ar (5000 SI) Response ime Varies with pilot line size and length, pilot pressure, pilot valve shift time & flow capacity (GM) Ordering Information D 81V L Directional Control Valve NF D08 CEO 8 Code Symbol Code Symbol * 008* 030** 009** asic Valve Lever Operated ilot * 008 & 020 spools have closed crossover. ** 009 & 030 spools have open crossover. Series D81VL Spool Style ilot Supply Seal Valve and Drain Variations Code Description Code Description N Nitrile Omit Standard V Fluorocarbon Code Description 1 Int. pilot/ext. drain 2 Ext. pilot/ext. drain 4# Int. pilot/int. drain 5 Ext. pilot/int. drain # Not available with 002, 008, 009 & 030 spools. Code Description Symbol Sgl. operator, 2 position, spring offset. to and to in offset position. C Dbl. operator, 3 position, spring centered. D Dbl. operator, 2 position, detent. 7 ilot Choke Meter Out 8 Stroke dj. 9 Stroke dj. 60 ilot Choke Meter In 89 Stroke dj. & Design Series NOE: Not required when ordering. LH SECION Valve schematic symbols are per NF/NSI standards, providing flow to when energizing operator. Note operators reverse sides for #9 spool. See installation information for details. E Sgl. operator, 2 position, spring centered. to and to in shifted position. H Sgl. operator, 2 position, spring offset. to and to in offset position. K Sgl. operator, 2 position. Spring centered. to and to in shifted position. his condition varies with spool code. Valve Weight: 19.6 kg (43.2 lbs.) Standard olt Kit: K228 Metric olt Kit: KM228 vailable with 020 & 030 spools only. old: Designates ier I products and options. Non-old: Designates ier II products and options. hese products will have longer lead times. D81.indd, dd 175 arker Hannifin Corporation Elyria, Ohio, US

41 Dimensions Inch equivalents for millimeter dimensions are shown in (**) Lever Operated Series D81VL LH SECION Note: 57mm (2.24") from bottom of bolt hole counterbore to bottom of valve. D81.indd, dd 176 arker Hannifin Corporation Elyria, Ohio, US

42 echnical Information General Description Series D8 directional control valves are 5-chamber, pilot operated valves. hey are available in 2 or 3-position styles. hese valves are manifold or subplate mounted, and conform to NF s D08, CEO 8 mounting pattern. Features Low pressure drop design. Hardened spools provide long life. Specifications Mounting attern NF D08, CEO 8, NG25 Max. Operating ressure 345 ar (5000 SI) Max. ank Line ressure 345 ar (5000 SI) Max. Drain ressure 345 ar (5000 SI) Min. ilot ressure 5.1 ar* (75 SI) Max. ilot ressure 345 ar (5000 SI) Nominal Flow 302 LM (80 GM) Max. Flow See Reference Data Chart * 6.9 ar (100 SI) for 2, 8, 9 & 12 spools For flow path, pilot drain and pilot pressure details, see Installation Information. Ordering Information D 8 Series D8 Response ime Response time will vary with pilot line size, pilot line length, pilot pressure shift time and flow capacity of the control valve. Shift Volume he pilot chamber requires a volume of 1.35 in 3 (22.1 cc) for center to end. LH SECION Directional Control Valve Valve schematic symbols are per NF/NSI Valve Weight: 18.9 kg (41.7 lbs.) Standard olt Kit: K228 Metric olt Kit: KM228 standards, providing flow to when energizing operator X. Note operators reverse sides for #9 spool. See installation information for details. old: Designates ier I products and options. D81.indd, dd NF D08 CEO 8 DIN NG25 Code Symbol Code Symbol * 7 30** 9** asic Valve * 20 spool has closed crossover. ** 9 & 30 spools have open crossover. ctuator Spool Style ilot Supply Seal Valve and Drain Variations Oil Operator Code ype N Nitrile V Fluorocarbon Code Description 2 Ext. ilot / Ext. Drain 5# Ext. ilot / Int. Drain # vailable in and H style only. Code Description Symbol Sgl. operator, 2 position, spring offset. to and to in offset position. C Dbl. operator, 3 position, spring centered. H Sgl. operator, 2 position, spring offset. to and to in offset position. vailable with 20 & 30 spools only. Code Description Omit Standard 7 ilot Choke Meter Out 8 Stroke dj. End 9 Stroke dj. End 60 ilot Choke Meter In 89 Stroke dj. & Ends his condition varies with spool code. Non-old: Designates ier II products and options. hese products will have longer lead times. Design Series NOE: Not required when ordering. 177 arker Hannifin Corporation Elyria, Ohio, US

Directional Control Valves. General Description. Operation. Features

Directional Control Valves. General Description. Operation. Features echnical Information General Description W directional control valves are 5-chamber, pilot operated, solenoid controlled valves, hey are available in 2 or 3-position styles. hese valves are manifold or

More information

Directional Control Valves Series D81V. General Description. Operation. Features. Specifications

Directional Control Valves Series D81V. General Description. Operation. Features. Specifications echnical Information General Description W directional control valves are 5-chamber, pilot operated, solenoid controlled valves. hey are available in 2 or 3-position styles. hese valves are manifold or

More information

Directional Control Valves. Features. Application. Operation

Directional Control Valves. Features. Application. Operation Introduction pplication hydraulic directional control valves are high performance, solenoid controlled, pilot operated, 2-stage, 4-way valves. hey are available in 2 or 3-position styles and are manifold

More information

Directional Control Valves. Application. Features. Operation.

Directional Control Valves. Application. Features. Operation. Catalog HY14-2500/US Introduction pplication Series D101 hydraulic directional control valves are high performance, solenoid controlled, pilot operated, 2-stage, 4-way valves. hey are available in 2 or

More information

Directional Control Valves. General Description. Operation. Features

Directional Control Valves. General Description. Operation. Features echnical Information Series D61VW General Series D61VW directional control valves are 5-chamber, pilot operated, solenoid controlled valves, hey are available in 2 or 3-position styles. hese valves are

More information

Directional Control Valves. General Description. Operation. Features

Directional Control Valves. General Description. Operation. Features echnical Information Series D101VW General Series D101VW directional control valves are 5-chamber, pilot operated, solenoid controlled valves. hey are available in 2 or 3-position styles. hese valves are

More information

Directional Control Valves. Application. Features. Operation

Directional Control Valves. Application. Features. Operation Catalog HY14-2500/US Introduction pplication Series D81 hydraulic directional control valves are high performance, solenoid controlled, pilot operated, 2-stage, 4-way valves. hey are available in 2 or

More information

Directional Control Valves. Application. Features. Operation

Directional Control Valves. Application. Features. Operation Catalog HY14-2502/US Introduction pplication Series D81 hydraulic directional control valves are high performance, solenoid controlled, pilot operated, 2-stage, 4-way valves. hey are available in 2 or

More information

Directional Control Valves. Features. Application. Operation

Directional Control Valves. Features. Application. Operation Catalog HY14-2502/US Introduction pplication Series D31 hydraulic directional control valves are high performance, solenoid controlled, pilot operated, 2-stage 4-way valves. hey are available in 2 or 3-

More information

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style Introduction pplication hydraulic directional control valves are high performance, direct operated 4-way valves. hey are available in 2 or 3-position styles. hey are manifold mounted valves, which conform

More information

Directional Control Valves. Features. Application. Operation

Directional Control Valves. Features. Application. Operation Introduction pplication Series D31 hydraulic directional control valves are high performance, solenoid controlled, pilot operated, 2-stage, 4-way valves. hey are available in 2 or 3-position styles and

More information

Directional Control Valves

Directional Control Valves echnical Information General Description he D1VW Series directional control valves are highperformance, 4-chamber, direct operated, wet armature solenoid controlled, 3 or 4-way valves. hey are available

More information

Directional Control Valves Series D111VW. General Description. Features. Performance Curves

Directional Control Valves Series D111VW. General Description. Features. Performance Curves Technical Information General valves are piloted by a D1VW valve. The valves can be ordered with position control. The minimum pilot pressure must be ensured for all operating conditions of the directional

More information

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style Introduction pplication hydraulic directional control valves are high performance, direct operated 4-way valves. hey are available in 2 or 3-position styles. hey are manifold mounted valves, which conform

More information

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style Catalog HY14-2500/US Introduction pplication hydraulic directional control valves are high performance, direct operated 4-way valves. hey are available in 2 or 3-position styles. hey are manifold mounted

More information

Directional Control Valves. Application. Features. Operation. D3W Solenoid Operated Conduit Cavity Style. D3W Solenoid Operated Hirschmann (DIN) Style

Directional Control Valves. Application. Features. Operation. D3W Solenoid Operated Conduit Cavity Style. D3W Solenoid Operated Hirschmann (DIN) Style Catalog HY14-2500/US Introduction pplication Series D3 hydraulic directional control valves are high performance, direct operated 4-way valves, available in 2 or 3-position. hey are manifold mounted which

More information

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US LH Industrial Hydraulic Valves Directional Control, ressure Control, Sandwich, Subplates & Manifolds, ccessories Catalog HY14-2500/US echnical Information General Description Series D1VW directional control

More information

Hydraulics 1. Directional Control Valves Series D1M. Features. Application. Operation. D1MW Solenoid Operated Free Lead Wire

Hydraulics 1. Directional Control Valves Series D1M. Features. Application. Operation. D1MW Solenoid Operated Free Lead Wire ulletin 2544-1/US Introduction pplication arker D1M Series hydraulic directional control valves are high performance, direct operated 4-way valves. hey are available in 2 or 3 position styles. hey are

More information

Série D3 Válvula Direcional CETOP 5 e NG 10. Catálogo HY /US

Série D3 Válvula Direcional CETOP 5 e NG 10. Catálogo HY /US Série D3 Válvula Direcional CETOP 5 e NG 10 Catálogo HY14-2502/US Catalog HY14-2502/US Introduction pplication Series D3 hydraulic directional control valves are high performance, direct operated 4-way

More information

Operation. D3W Solenoid Operated Conduit Box Style. D3W Solenoid Operated Hirschmann (DIN) Style

Operation. D3W Solenoid Operated Conduit Box Style. D3W Solenoid Operated Hirschmann (DIN) Style Catalog HY14-252/US Introduction pplication arker D3 Series hydraulic directional control valves are high performance, direct operated 4-way valves, available in 2 or 3 position. hey are manifold mounted

More information

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US LH Industrial Hydraulic Valves Directional Control, ressure Control, Sandwich, Subplates & Manifolds, ccessories Catalog HY14-2500/US Industrial Hydraulic Valves LH WRNING USER RESONSIILIY FILURE OR IMROER

More information

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US Industrial Hydraulic Valves Directional Control, ressure Control, Sandwich, Subplates & Manifolds, ccessories Catalog HY14-2500/US Industrial Hydraulic Valves WRNING USER RESONSIILIY FILURE OR IMROER SELECION

More information

Directional Control Valves. General Description. Features. Specifications

Directional Control Valves. General Description. Features. Specifications Technical Information General Description directional control valves are high-performance, 4-chamber, direct operated, wet armature, solenoid controlled, 3 or 4-way valves. They are available in 2 or 3-position

More information

Directional Controls

Directional Controls VICKERS Directional Controls Solenoid Operated Directional Control Valves NF D05, ISO-4401-05 DG4S*-01**-5* ir Gap ype Revised 8/97 671 able of Contents DG4S*-01 Model Code..................................................................................

More information

Bulletin HY M6/US Service Bulletin. Series D1VW, H Style 91 Design. Effective: May 1, Directional Control Valves

Bulletin HY M6/US Service Bulletin. Series D1VW, H Style 91 Design. Effective: May 1, Directional Control Valves Service Bulletin 91 Design Effective: May 1, 2007 FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This

More information

Bulletin HY M2/US Service Bulletin. Series D1VW, C Style 91 Design. Effective: May 1, Directional Control Valves

Bulletin HY M2/US Service Bulletin. Series D1VW, C Style 91 Design. Effective: May 1, Directional Control Valves Service Bulletin 91 Design Effective: May 1, 2007 FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This

More information

Direct Operated Proportional DC Valves

Direct Operated Proportional DC Valves echnical Information Direct Operated roportional DC Valves Series D1F and D3F General Series D1F and D3F directional control valves of nominal sizes NG6 (CEO 3) and NG10 (CEO 5) respectively, provide variable

More information

Bar 35 PSI 500. Pressure Drop L/M GPM. Flow

Bar 35 PSI 500. Pressure Drop L/M GPM. Flow NF D3 O E R I N G N D E C H N I C L D RINGS Maximum Flow... See Chart Maximum Operating ressure (, and orts)... 3 ar ( SI) Maximum ank Line ressure... 13 ar (1 SI) Mounting attern... ISO 441--3-4-, NF-D3

More information

Directional Controls

Directional Controls Vickers Directional Controls Mechanical ctuators Directional Control Valves Directional Control Valves 310 bar (4500 psi) Flows to 114 l/min (30 USgpm) NF D05, ISO-4401-05 DG1V4-01**-10 Knob Operated DG17V4-01**-10

More information

Manapak Sandwich Valves. General Description

Manapak Sandwich Valves. General Description echnical Information Series RM General Description RM Series relief valves limit system pressure by opening to tank when system pressure reaches the valve setting. With D3 size, they can also be configured

More information

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX: SECIFICIONS D05H attern Directional Control Valves lso refer to "Directional Valve Features, Selection and Operating Recommendations" (dynexdcvoperating.pdf) CONC INFORMION US Headquarters 770 Capitol

More information

Directional Controls

Directional Controls Vickers Directional Controls ilot Operated Directional Valves DG3V-10 Hydraulic ilot Operated; 1100 l/min (290 USgpm) 350 bar (5000 psi) DG5V-10 Solenoid ilot Operated; 1100 l/min (290 USgpm) 350 bar (5000

More information

D07 & D08. Series 35 Solenoid Valves D07 D Friendship Drive, Magnolia, TX Tel.: Fax:

D07 & D08. Series 35 Solenoid Valves D07 D Friendship Drive, Magnolia, TX Tel.: Fax: GENERL FEURES SNDRD FEURES High ressure/ High Flow: 65 gpm/ psi ilot Operation: Main spool controlled by D0 solenoid pilot valve- allows for addition of modular valves to reduce shifting shock. Oil Immersed,

More information

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX: SECIFICIONS D0H attern Directional Control Valves lso refer to "Directional Valve Features, Selection and Operating Recommendations" (dynexdcvoperating.pdf) CONC INFORMION US Headquarters 770 Capitol Drive

More information

High Pressure, Subplate Mounted Directional Control Valves

High Pressure, Subplate Mounted Directional Control Valves ENGINEERING SECIFICIONS High ressure, Subplate Mounted Directional Control Valves MODEL H05 5 gpm (19 L/min) nominal 8000 psi (560 bar) Sliding-spool H05 valves provide true four-way control in a simple

More information

Directional Control Valves. General Description. Features. Specifications

Directional Control Valves. General Description. Features. Specifications echnicl Informtion Generl Description directionl control vlves re high performnce, 5-chmer, direct operted, wet rmture, solenoid controlled, 3 or 4-wy vlves. hey re ville in 2 or 3-position nd conform

More information

Bankable Control Valves

Bankable Control Valves Hydraulics ankable Control Valves Catalog 3123/US Catalog 3123/US Contents ankable Control Valves WRNING FILURE OR IMROER SELECION OR IMROER USE OF HE RODUCS ND/OR SYSEMS DESCRIED HEREIN OR RELED IEMS

More information

High Pressure, Subplate Mounted Directional Control Valves

High Pressure, Subplate Mounted Directional Control Valves ENGINEERING SECIFICIONS High ressure, Subplate Mounted Directional Control Valves MODEL H03 5 gpm (19 L/min) nominal 10 000 psi (700 bar) H03 valves are rated for 5 gpm (19 L/min) nominal flow at pressures

More information

Pilot-Operated Directional Control Valves Series D3 - D11

Pilot-Operated Directional Control Valves Series D3 - D11 Catalogue HY11-500/UK Characteristics The D31, D41, D81, D91 and D111 are electrical controlled 4/3 or 4/ way directional control valves. The valves are pilot-operated by an NG6 valve. Pressure and flow

More information

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX: DIRECIONL VLVE OERION Directional Valve Features, Selection and Operating Recommendations CONC INFORMION US Headquarters Dynex/Rivett Inc. 770 Capitol Drive ewaukee, WI 3072 U.S.. el: 262-69-2222 FX: 262-69-032

More information

Pilot Operated Directional Valves

Pilot Operated Directional Valves ilot Operated Directional Valves Catalog DG3V-10 Hydraulic ilot Operated; 1100 l/min (290 USgpm) 350 bar (5000 psi) DG5V-10 Solenoid ilot Operated; 1100 l/min (290 USgpm) 350 bar (5000 psi) NF D10, ISO-4401-10,

More information

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW Characteristics The D31, D41, D81, D91 and D111 are electrically controlled 4/3 or 4/ way directional control valves. The valves are pilot operated by an NG6 valve. Pressure and flow of the pilot oil have

More information

EManually Operated Directional Valves

EManually Operated Directional Valves DIRECIONL CONROLS hese valves may be used to manually shift the spool position and change the direction of oil flow. hreaded Connections Sub-late Mounting Specifications DM--C - DM--D - DM--D - DM-- -

More information

Directional Controls

Directional Controls VICKERS Directional Controls DG3V-7, 20 Series, ilot Operated DG5V-7, 40 Series, Solenoid Controlled, ilot Operated ISO 440 Size 07 ypical Section DG5V-7-2C Spring-Centered Valve Example Basic Characteristics

More information

"G" SERIES SHOCKLESS TYPE SOLENOID OPERATED DIRECTIONAL VALVES G-DSG-01/03 (1/8, 3/8) "G" SERIES SHOCKLESS TYPE

G SERIES SHOCKLESS TYPE SOLENOID OPERATED DIRECTIONAL VALVES G-DSG-01/03 (1/8, 3/8) G SERIES SHOCKLESS TYPE "G" SRIS SHOCKLSS Y NOID ORD DIRCIL VLVS G-DSG-1/3 (1/, 3/) "G" SRIS SHOCKLSS Y NOID CROLLD ILO ORD DIRCIL VLVS G-DSHG-/ (1/, 3/) Mounting Up to 5 Ma (33 SI), 5 L /m in (.1 U.S.GM) ub. C-5 DIRCIL CROLS

More information

Directional Control Valve Series 4D01 (DENISON)

Directional Control Valve Series 4D01 (DENISON) Characteristics The Denison series 4D01 is a solenoid operated directional control valve size NG06 in -chamber design. It is direct operated by wet pin solenoids. The 4D01 is available with a Soft Shift

More information

Chapter 2: Directional Control Valves

Chapter 2: Directional Control Valves Contents Chapter : Directional Control Valves Series Description Direct operated Pilot operated Page DIN / ISO 06 10 16 5 3 10 16 5 3 Seat valves, electrically operated D1SE - Spool valves, electrically

More information

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW Characteristics The pilot operated valves are available in 4 sizes: D31DW NG10 (standard) D31NW NG10 (high flow) D41VW NG16 D81VW NG5 (for port diameter up to 6 mm) D91VW NG5 (for port diameter up to 3

More information

Pilot Operated Directional Valves

Pilot Operated Directional Valves ilot Operated Directional Valves Catalog DG3V-8; 7 l/min (185 USgpm) 35 bar (5 psi) DG5V-8; 7 l/min (185 USgpm) 35 bar (5 psi) NF D8, ISO-441-8, CEO 8 Introduction General Description he Size 8 Directiona

More information

4/2- and 4/3-Way Proportional Directional Control Valve Direct Operated, Model 4 WRA (Series 1X) PSI (315 bar) H/A 1768

4/2- and 4/3-Way Proportional Directional Control Valve Direct Operated, Model 4 WRA (Series 1X) PSI (315 bar) H/A 1768 /- and /-Way roptional Directional Control Valve Direct Operated, Model WR (Series X) Size 6 and... 6 SI ( bar).... GM (9 L/min) R 9 /6.98 R 9 /6.98 Replaces:.9 Characteristics: F the open loop control

More information

Directional Control Valve Series D1VW

Directional Control Valve Series D1VW Characteristics The NG6 directional control valve series D1VW provides high functional limits up to 8 l/min in combination with a very low, energy-saving pressure drop. A wide variety of spool options

More information

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX: SPECIFICIONS D08H Pattern Directional Control Valves lso refer to "Directional Valve Features, Selection and Operating Recommendations" (dynexdcvoperating.pdf) CONC INFORMION US Headquarters 770 Capitol

More information

RA / Accumulator unloading valve, pilot operated, Model DA 6 V.., series 4X. Ordering details DA 6 V 4X. Preferred models 1/8.

RA / Accumulator unloading valve, pilot operated, Model DA 6 V.., series 4X. Ordering details DA 6 V 4X. Preferred models 1/8. R 26 404/06.9 ccumulator unloading valve, pilot operated, Model D 6 V.., series 4X Size 6 up to 4500 SI (315 bar) up to.00 GM (30 L/min) R 26 404/04.9 Features: For subplate mounting: porting pattern to

More information

EManually Operated Directional Valves

EManually Operated Directional Valves DIRECIONL CONROLS hese valves may be used to manually shift the spool position and change the direction of oil flow. hreaded Connections Sub-late Mounting Specifications DM--C - DM--D - DM--D - DM--B -

More information

Mounting and Assembly of Sandwich Bodies

Mounting and Assembly of Sandwich Bodies Mounting and ssembly of Sandwich odies Mounting of ISO 0 (CEO ) Sandwiches Many of Sun s ISO 0 (CEO ) sandwich bodies are designed for multi-functional use to permit maximum circuit flexibility. With the

More information

VSD10M DIRECTIONAL CONTROL VALVES SOLENOID ACTUATED, PILOT OPERATED

VSD10M DIRECTIONAL CONTROL VALVES SOLENOID ACTUATED, PILOT OPERATED NFPA SIZE D10 TYPICAL PERFORMANCE SPECIFICATIONS Performance is measured on a four-way circuit (full circuit). Performance may be reduced from that shown if a three-way circuit (half circuit) is used,

More information

Directional control valves NG6...NG32 D03...D10 6

Directional control valves NG6...NG32 D03...D10 6 Directional control valves NG6...NG32 D03...D10 6 DIRECIONL CONROL VLVES 1 Index DO3 (NG6) age 2 to 22 D05 (NG10) age 23 to 42 D07 (NG16) age 43 to 54 D08 (NG25) 3000 SI age 55 to 65 D08 (NG25) 4600 SI

More information

Monobloc and Sectional Directional Control Valves

Monobloc and Sectional Directional Control Valves Monobloc and Sectional irectional Control Valves 200 - - 991210 - - 03/09.2015 1/220 8 Sectional directional control valves HS11 8 valves... p.101 Contents 8.1 General specification 101 8.2 imensional

More information

Series Shockless Type Solenoid Controlled Pilot Operated Directional Valves

Series Shockless Type Solenoid Controlled Pilot Operated Directional Valves Solenoid Controlled ilot Operated Directional Valves Electronic Circuit X Specifications Descriptions G-DSHG-4-3C - - - -/9 G-DSHG-6-3C - - - -/9 Max. Flow /min (U.S.GM) 16 (4.3) (66.1) 1 1 Max. Operating

More information

Directional Control Valves

Directional Control Valves Frequently sked Questions N-1 Frequently sked Questions What is the function of a directional control valve? directional control valve is the extend and retract control for your hydraulic cylinders. It

More information

Directional Control Valve

Directional Control Valve Characteristics The NG6 directional control valve series D1VW provides high functional limits up to 8 l/min in combination with a very low, energy-saving pressure drop. wide variety of spool options allows

More information

3/2 and 4/2 directional seat valves with solenoid actuation

3/2 and 4/2 directional seat valves with solenoid actuation 1/16 3/ and 4/ directional seat valves with solenoid actuation RE 047-XH-B/01.10 Replaces: 09.07 ype E-.SE 6...XH ype W-.SE 6...XH Size 6 Component series 6X Maximum operating pressure 40 bar Maximum flow

More information

Vickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi)

Vickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi) Vickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi) Revised 2/93 GB C 2037 Table of Contents Model Code...................................................................................................

More information

Pilot Operated Directional Control Valves Series D1VP, D3DP, D4P, D9P, D11P

Pilot Operated Directional Control Valves Series D1VP, D3DP, D4P, D9P, D11P Characteristics Series D1VP, D3DP, D4P, D9P, D11P The D1VP is a hydraulically controlled 4/3 or 4/ way directional control valve. The valve can be operated either by the pilot ports X and Y via the subplate

More information

Directional Control Valves

Directional Control Valves Frequently sked Questions Frequently sked Questions What is the function of a directional control valve? directional control valve is the extend and retract control for your hydraulic cylinders. It provides

More information

Pressure Control Valves Series R. General Description. Specifications. Flow Data

Pressure Control Valves Series R. General Description. Specifications. Flow Data Catalog Y14-2502/US Technical Information Series R General Description Series R direct relief valves limit system pressure by opening to tank when system pressure reaches the valve setting. Specifications

More information

DIRECTIONAL CONTROLS. Pilot Operated Directional Valves. Specifications

DIRECTIONAL CONTROLS. Pilot Operated Directional Valves. Specifications ilot Operated Directional s DIRECIONL CONROLS hese valves perform a change over of spool by hydraulic pilot and shift the direction of oil flow. EIC-E-04-0 Specifications Model Numbers Maximum Flow L/min.

More information

385 & 962 Series The lectroaire valve is a compact, air operated, electrically lectroaire valves can be remotely mounted for control of double acting

385 & 962 Series The lectroaire valve is a compact, air operated, electrically lectroaire valves can be remotely mounted for control of double acting Model Number Index Housing Series Type ort Variation Voltage 962 2 001 40 Series Solenoid Operated Housing Type 962 Valve less racket 972* Valve less racket 902 Valve less racket 385 Valve with racket

More information

p max (see table of performances) Q max (see table of performances) MD1K MD1KD bar

p max (see table of performances) Q max (see table of performances) MD1K MD1KD bar 41 510/107 ED EXLOSION-ROOF VERSION SOLENOID OERED DIRECIONL CONROL VLVES in compliance with EX 94/9/CE SERIES 21 MD1K-MD1KD ISO 4401-03 (CEO 03) E44K-E44KD CEO 05 E074K-E074KD ISO 4401-07 (CEO 07) E54K-

More information

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1. Solenoid Valves Poppet and Spool type solenoid actuated valves for applications up to 5 bar (5 psi) and 7 L/min (6 USgpm) n Eaton Brand ETON Screw-In Cartridge Valves E-VLSC-MC-E November 9 -. Solenoid

More information

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX: SPECIFICAIONS D05 Pattern Directional Control Valves Also refer to "Directional Valve Features, Selection and Operating Recommendations" (dynexdcvoperating.pdf) CONAC INFORMAION USA Headquarters Dynex/Rivett

More information

RA / /3, 4/2 and 3/2-Way Directional Valves Model.WE 10.../.D, Series 3X with Wet Pin DC Solenoids. Functional description, section

RA / /3, 4/2 and 3/2-Way Directional Valves Model.WE 10.../.D, Series 3X with Wet Pin DC Solenoids. Functional description, section 4/3, 4/2 and 3/2-Way Directional Valves Model.WE.../.D, Series 3X with Wet in DC Solenoids Size (D )... 3 SI... 2 GM (2 ar) (8 L/min) RA 23 37/6.98 Replaces: 2.96 Features: Direct solenoid operated directional

More information

3/2 and 4/2 directional poppet valve with solenoid actuation

3/2 and 4/2 directional poppet valve with solenoid actuation Courtesy of CM/Flodyne/Hydradyne Motion Control Hydraulic neumatic Electrical Mechanical (800) 426-5480 www.cmafh.com 3/2 and 4/2 directional poppet valve with solenoid actuation ype M-.SED Size 10 Component

More information

Monobloc and Sectional Directional Control Valves

Monobloc and Sectional Directional Control Valves Monobloc and Sectional Directional Control Valves 200--991210-N-03/09.2015 03 / 10.04 1/220 11 Sectional directional control valves HDS30 Contents 11.1 General specifications 197 11.2 Dimensional data

More information

DFE10. solenoid control monoblock valve. Ordering codes. Description example : Diverter valve DFE10/3 A 18 ES - W VDC - SAE - <CVN>

DFE10. solenoid control monoblock valve. Ordering codes. Description example : Diverter valve DFE10/3 A 18 ES - W VDC - SAE - <CVN> DFE1 Ordering codes Description example : Diverter valve DFE1/3 18 ES - W 22-12VDC - SE - 1. 4. 5. 3. 5. 2. Valve is supplied painted as standard, with one coat of rimer black antirust paint II 5.

More information

3/2 and 4/2 directional seat valves with solenoid actuation

3/2 and 4/2 directional seat valves with solenoid actuation 1/16 /2 and 4/2 directional seat valves with solenoid actuation RE 22047-XH-B2/09.12 Replaces: 05.12 ype E-.SE 6...X... ype W-.SE 6...X... Size 6 Component series 6X Maximum operating pressure 420 bar

More information

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX: SPECIFICATIONS D03 Pattern Directional Control Valves Also refer to "Directional Valve Features, Selection and Operating Recommendations" (dynexdcvoperating.pdf) CONTACT INFORMATION USA Headquarters Dynex/Rivett

More information

Pressure Control Valves. General Description. Specifications. Ordering Information

Pressure Control Valves. General Description. Specifications. Ordering Information Catalog HY14-3000/US Technical Information Control Valves Series RCP General escription Series RCP in-line pressure control valves are chiefly used as remote control valves. They limit system pressure

More information

Hydraulic Power Units D, H, V-Pak and V-Pak Low Profile Series

Hydraulic Power Units D, H, V-Pak and V-Pak Low Profile Series aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Hydraulic ower Units D, H, V-ak and V-ak Low rofile Series HY28-2661-CD/US

More information

Pilot Operated Pressure Relief Valve Series R5V (Denison)

Pilot Operated Pressure Relief Valve Series R5V (Denison) Characteristics Pilot operated pressure relief valves series R5V have a similar design to the subplate mounted R4V series. The SAE flanges allow to mount the valves directly on the outlet flanges of pumps

More information

MDT. Monoblock directional control valves MDT - Directional control valve

MDT. Monoblock directional control valves MDT - Directional control valve Monoblock directional control valves - Directional control valve efore use, carefully read the GENERL INSRUCIONS FOR USE OF DIRECIONL CONROL VLVES echnical data Nominal flow 35 l/min 9. US gpm Nominal

More information

Solenoid valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

Solenoid valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) Hydraulic Screw-in Cartridge Valves (SiCV) Solenoid valves Poppet and Spool type solenoid actuated valves for applications up to 5 bar (5 psi) and 7 L/min (6 USgpm) Solenoid valves SOLENOID VLVES...- SV5-8-C/CM

More information

ANTI-SHOCK DIRECTIONAL CONTROL VALVES

ANTI-SHOCK DIRECTIONAL CONTROL VALVES ACTUATED, DIRECT OPERATED TYPICAL PERFORMANCE SPECIFICATIONS Performance is measured on a four-way circuit (full circuit). Performance may e reduced from that shown if a three-way circuit (half circuit)

More information

Monobloc and Sectional Directional Control Valves

Monobloc and Sectional Directional Control Valves Monobloc and Sectional Directional Control Valves motion and progress 200 991210 03 / 10.04 1/220 HDS11 8 Sectional directional control valves HDS11 8 Standard valves................................................................

More information

Directional Controls

Directional Controls Vickers Directional Controls Wet Armature Solenoid Operated Directional Control Valves Model DGV-, Series Typical Construction of a Spring-Centered DC Valve with Variable Speed Pilot Control passage Speed

More information

SECTION TITLE HEC2003/2004 SERIES SERVO VALVE SYSTEM ACCESSORIES KEY FEATURES

SECTION TITLE HEC2003/2004 SERIES SERVO VALVE SYSTEM ACCESSORIES KEY FEATURES SECION ILE HEC2003/2004 SERIES SERVO VLVE SYSEM he HEC2003/2004 Series Servo System features a high response servo valve, a manifold mounted filter, and three different mechanical mounting options. he

More information

Directional Control Valve Series D3W (Parker), 4D02 (Denison)

Directional Control Valve Series D3W (Parker), 4D02 (Denison) Characteristics Series D3W (Parker), 4D0 (Denison) The direct operated directional control valve size NG10 is available with both Parker (series D3W) and Denison (series 4D0) model codes. Both series are

More information

NG06. General Size NG6 NG10 Design

NG06. General Size NG6 NG10 Design Catalog HY14-255/US Series VY*K General Series VY*K pilot operated sequence valves feature proportional adjustment and an external drain. The external drain allows application as both a sequence valve

More information

EMechanically Operated Directional Valves

EMechanically Operated Directional Valves E DIRECIONL CONROLS Cam Operated Directional Valves hese valves may be used to shift the direction of oil flow by depressing the spool by way of a cam. Specifications Max. Operating Max. -Line Max. Flow

More information

High Pressure, High Flow Rate Modular Valves

High Pressure, High Flow Rate Modular Valves eatures Installation and mounting space can be minimized. No special skill is required for assembly and any addition or alternation of the hydraulic circuit can be made quickly and easily. roblems such

More information

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308 Cable ppendix Cable ppendix Multi-way cables The multi-pole connector cables used on SMC valves are common across several ranges. Cables are available in accordance with the MIL standard C-08 and also

More information

Pressure Compensator Valves Series R5P (SAE Flange Mounted) General Description. Features

Pressure Compensator Valves Series R5P (SAE Flange Mounted) General Description. Features Technical Information General Description Series R5P direct operated, 3-way pressure compensators can be combined with any type of fixed or adjustable flow resistor (throttle) to provide a load compensated

More information

Directional Controls

Directional Controls Vickers Directional Controls Pilot Operated Directional Control Valves DG5S4-10**-53 DG4S4-01-50 Air Gap Pilot Valve DG5S4-10**-80 DG4S4-01-60 Wet Armature Pilot Valve DG5S4-10** -90 DG4V-3S-60 Pilot Valve

More information

D05 Directional Control Valves

D05 Directional Control Valves Engineering D05 Directional Control Valves WFDG4S*4-01, 60 Design Wet Armature Solenoid Operated Max Pressure up to 248 Bar (3600 psi) Same Day Shipments www.fluidynefp.com Table of Contents Basic Characteristicts...2

More information

Solenoid directional valves type DPHI, DPHE, DPHER two stage, ISO 4401 size 10, 16, 25 and 32

Solenoid directional valves type DPHI, DPHE, DPHER two stage, ISO 4401 size 10, 16, 25 and 32 www.atos.com able E0854/E Solenoid al valves DHI, DHE, DHER two stage, ISO 440 size 0, 6, 5 and 3 DHI, DHE and DHER are spool, two or three position, two stage al solenoid valves. hey are operated by a

More information

Monobloc and Sectional Directional Control Valves

Monobloc and Sectional Directional Control Valves Monobloc and Sectional Directional Control Valves motion and progress 1/220 10 Sectional directional control valves HDS20 Contents 10.1 General specifications 177 10.2 Dimensional data 178 10.3 erformances

More information

Chapter 6: Check Valves

Chapter 6: Check Valves Contents Chapter : Check Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 0 10 1 25 32 Subplate Screw-in Slip-in Shuttle valves SSR -2 Check valves, direct operated

More information

Introduction. Pressure drops

Introduction. Pressure drops Directional control valves CETOP 5/NG0 Introduction The ARON directional control valves NG0 designed for subplate mounting with an interface in accordance with UNI ISO 440-05 - 04-0 - 94 standard (ex CETOP

More information

Pump Safety Block Model DBA... / DBAW, Series 1X

Pump Safety Block Model DBA... / DBAW, Series 1X ump Safety lock odel D... / DW, Series X Sizes to 6 SI ( bar) 7 G (65 L/min) R 5 88/.95 Replaces:.9 ermits low pressure start-up and by-pass of pump Direct mounting to SE pressure port of pump Light biasing

More information

High Response Type Proportional Electro-Hydraulic Directional and Flow Control Valves

High Response Type Proportional Electro-Hydraulic Directional and Flow Control Valves igh Response ype roportional Electro-ydraulic s igh response, high precision and high reliability are achieved by a combination of compact and powerful solenoid and spool-position-detection LVD. Direct

More information