Directional Control Valve Series D3W (Parker), 4D02 (Denison)

Size: px
Start display at page:

Download "Directional Control Valve Series D3W (Parker), 4D02 (Denison)"

Transcription

1 Characteristics Series D3W (Parker), 4D0 (Denison) The direct operated directional control valve size NG10 is available with both Parker (series D3W) and Denison (series 4D0) model codes. Both series are available with a soft shift option for smooth operation. An additional orifice in the solenoid anchor dampens the shifting time for D3W. For the 4D0 the orifice is located in the valve body. Technical data General Design Actuation Size Mounting interface Mounting position Directional spool valve Solenoid Ambient temperature [ C] Weight Hydraulic Max. operating pressure DIN NG10 / CETOP 05 / NFPA D05 DIN 4340 A10 / ISO 4401 / CETOP RP 11-H / NFPA D05 unrestricted, preferably horizontal [kg] 4.8 (1 solenoid), 6.3 ( solenoids) [bar] P, A B: 350; T: 10 (DC), 105 (AC), 10 (AC H ) Fluid Hydraulic oil in accordance with DIN 5154 / 5155 Fluid temperature [ C] Viscosity permitted [cst] / [mm²/s] Viscosity recommended [cst] / [mm²/s] Filtration ISO 4406 (1999); 18/16/13 (meet NAS 1638: 7) Flow max. Leakage at 50 bar Static / Dynamic Step response Electrical characteristics Duty ratio [l/min] 150 (DC); 115 (AC) Max. switching frequency [1/h] Protection class [ml/min] Up to 0 per flow path, depending on spool see table response time 100% ED; CAUTION: coil temperature up to 150 C possible IP 65 in accordance with EN 6059 (plugged and mounted) K J U G Y T Supply voltage / ripple [V] 1 V = 4 V = 98 V = 05 V = With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations. 110V at 50Hz/ 10V at 60Hz 30V at 50Hz/ 40V at 60Hz Tolerance supply voltage [%] ±10 ±10 ±10 ±10 ±5 ±5 Current consumption hold [A] / / 0.36 Current consumption in rush [A] / / 1.7 Power consumption hold [W] / / 86 Power consumption in rush [W] / / 408 Solenoid connection Connector as per EN , solenoid identification as per ISO Wiring min. Wiring length max. [mm²] 3 x 1.5 recommended [m] 50 recommended -43

2 Ordering Series D3W (Parker) D 3 W Directional control valve Size DIN NG10 CETOP 05 NFPA D05 Wet pin solenoid Spool type Spool position Seals 3 position spools Spool type a 0 b 1 N V Seals NBR FPM C 3 position spools all 3 position spools Standard Spool type 8 and 9 3 positions. Spring offset in position 0. Operated in position a or b ) 9 1) E Operated in position a. Operated in position b. positions. Spring offset in position ) 11 1 F Spring offset in position b. Spring offset in position a. positions. Operated in position K Operated in position b. Operated in position a. positions. Spring offset in position 0. 1 ) ) 31 ) M Spring offset in position a. Spring offset in position b. positions. Operated in position 0. 3 ) 81 ) 8 ) 10 ) position spools Spool type a b ) 1) Consider specific spool position. ) Only available for DC voltage. B D H position spools Spool position positions. Spring offset in position b. Operated in position a. positions. Operated in position a or b. No centre or offset position. positions. Spring offset in position a. Operated in position b. -44

3 Ordering Series D3W (Parker) W Solenoid voltage Connector as per Solenoid option EN , without plug (Please order plug separately) Shift response Design series (not required for ordering) Solenoid voltage K 1V = J 4V = U 3) 98V = G 3) 05V = Y T 110V 50Hz / 10V 60Hz 30V 50Hz / 40V 60Hz 3) To be used with retifier plug when DC solenoids are used with AC input. omit S4 4) S7 4) 4) Only for DC Shift response Standard response orifice diameter 1.0 mm orifice diameter 1.5 mm omit H T Solenoid option Standard solenoid with manual override High pressure solenoid tube for AC. Tank pressure up to 10bar without manual override Further spool types and solenoid voltages on request. -45

4 Ordering Series 4D0 (Denison) 4D0 C Directional control valve size DIN NG10 CETOP 05 NFPA D05 Body Control Spool type Spool position End cap Design series 3 D 3 position spools Spool type a 0 b Control 1 1 solenoid solenoids 7 Body Standard 3-chamber 5-chamber for soft-shift (G3) solenoids and pos. detent (only for spool types 11 and 51) position spools Spool position position spools Spool position End cap 01 for control 1 0 for control and 7 3 positions. Spring centered to 0. positions. Spring centered energized to b. positions. Spring centered energized to a. positions. Spring offset to b energized to a. positions. Spring offset to a energized to b. positions detent. Operated in a or b. No centre or spring offset position. position spools Spool type a b

5 Ordering Series 4D0 (Denison) Seals Seals 1 NBR 5 FPM Solenoid voltage Options Solenoid voltage G0R 1V = G0Q 4V = GAR * 98V = GAG * 05V = W30 W31 110V 50Hz / 10V 60Hz 30V 50Hz / 40V 60Hz * To be used with retifier plug when DC solenoids are used with AC input. omit G3 Options Solenoid connector as per EN without plug. With manual override Soft shift with orifice in body (for DC and body D only) 3 Without manual override Further spool types and solenoid voltages on request. -47

6 Flow Curve Diagram The flow curve diagram shows the flow versus pressure drop curves for all spool types. For each spool type, Series D3W (Parker), 4D0 (Denison) operating position and flow direction the relevant curve number is given in the table below. Spool Position b Position a Position 0 D3W 4D0 P->A B->T P->B A->T P->A P->B A->T B->T P->T A->B P->B A->T P->A B->T P->A P->B A->T B->T P->T A->B Position b Position a P->A P->B A->B P->B A->T P->A B->T P->A P->B A->B Flow curve diagram -48

7 Shift Limits Shift limits, DC voltage * Series D3W (Parker), 4D0 (Denison) The diagram below specifies the shift limits for valves with DC and AC solenoids. Valves with spool position F or M can only be operated up to 70% of the limits. The specifications apply to a viscosity 35mm /s and balanced flow conditions. The shift limits can be considerably lower at unbalanced flow conditions. To avoid flow rates beyond the shift limits, a plug-in orifice can be inserted in the P-port. Shift limits, AC voltage * Measured at 90% U nom and warm solenoids. * For 4D0 spool code see flow curve table. -49

8 Shift Limits / Response Times Series D3W (Parker) Shift limits soft shift The diagram below specifies the shift limits. Valves with spool position F or M can only be operated up to 70% of the limits. The specifications apply to a viscosity 35mm /s and balanced flow conditions. The shift limits can be considerably lower at unbalanced flow conditions. To avoid flow rates beyond the shift limits, a plug-in orifice can be inserted in the P-port. Measured at 90% U nom and warm solenoids. Response times D3W Soft Shift Orifice size Energize De-energize (Standard) 105 ms (DC) 1 ms (AC)* 85 ms (DC) 35 ms (AC)* S4 1.0 mm 30 ms 550 ms S mm 160 ms 370 ms Step response times were obtained under the following conditions: υ = 35 mm /s at 50 C with the valve operating at 175 bar and 65 l/min. Published response times are nominal and may vary with spool, flow, pressure and temperature. * For AC input and soft shift use rectifier plug. Acceleration for different orifice sizes (archived against a valve without soft shift) Orifice in anchor * For even softer shifting, the proportional spools 81, 8, 101 and 10 can be used. * Note: For 4D0 the orifice is located in the Z-channel of the valve body. -50

9 Dimensions Series D3W (Parker), 4D0 (Denison) Interface EN , DC solenoid B, E, F -style H, K, M -style C, D -style Interface EN , AC solenoid B, E, F -style H, K, M -style C, D -style Surface finish BK385 4x M6x40 DIN Nm ±15% NBR: SK-D3W-30 FPM: SK-D3W-V30 The space necessary to remove the plug per EN , design type AF is at least 15 mm. The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm. -51

10 Notes -5

Directional Control Valve Series 4D01 (DENISON)

Directional Control Valve Series 4D01 (DENISON) Characteristics The Denison series 4D01 is a solenoid operated directional control valve size NG06 in -chamber design. It is direct operated by wet pin solenoids. The 4D01 is available with a Soft Shift

More information

Directional Control Valve Series D3W Soft Shift

Directional Control Valve Series D3W Soft Shift Characteristics The D3W is a 3-chamber, electrically controlled 4/3 or 4/ way directional control valve. It is activated directly by solenoids with screwed in wet pin armature. The soft shifting of this

More information

Directional Control Valve Series D1VW

Directional Control Valve Series D1VW Characteristics The NG6 directional control valve series D1VW provides high functional limits up to 8 l/min in combination with a very low, energy-saving pressure drop. A wide variety of spool options

More information

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW Characteristics The D31, D41, D81, D91 and D111 are electrically controlled 4/3 or 4/ way directional control valves. The valves are pilot operated by an NG6 valve. Pressure and flow of the pilot oil have

More information

Directional Control Valve

Directional Control Valve Characteristics The NG6 directional control valve series D1VW provides high functional limits up to 8 l/min in combination with a very low, energy-saving pressure drop. wide variety of spool options allows

More information

Pilot-Operated Directional Control Valves Series D3 - D11

Pilot-Operated Directional Control Valves Series D3 - D11 Catalogue HY11-500/UK Characteristics The D31, D41, D81, D91 and D111 are electrical controlled 4/3 or 4/ way directional control valves. The valves are pilot-operated by an NG6 valve. Pressure and flow

More information

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW Characteristics The pilot operated valves are available in 4 sizes: D31DW NG10 (standard) D31NW NG10 (high flow) D41VW NG16 D81VW NG5 (for port diameter up to 6 mm) D91VW NG5 (for port diameter up to 3

More information

Pilot Operated Directional Control Valves Series D1VP, D3DP, D4P, D9P, D11P

Pilot Operated Directional Control Valves Series D1VP, D3DP, D4P, D9P, D11P Characteristics Series D1VP, D3DP, D4P, D9P, D11P The D1VP is a hydraulically controlled 4/3 or 4/ way directional control valve. The valve can be operated either by the pilot ports X and Y via the subplate

More information

Chapter 2: Directional Control Valves

Chapter 2: Directional Control Valves Contents Chapter : Directional Control Valves Series Description Direct operated Pilot operated Page DIN / ISO 06 10 16 5 3 10 16 5 3 Seat valves, electrically operated D1SE - Spool valves, electrically

More information

Pilot Operated Pressure Relief Valve Series R5V (Denison)

Pilot Operated Pressure Relief Valve Series R5V (Denison) Characteristics Pilot operated pressure relief valves series R5V have a similar design to the subplate mounted R4V series. The SAE flanges allow to mount the valves directly on the outlet flanges of pumps

More information

Directional Seat Valve Series D4S (Denison)

Directional Seat Valve Series D4S (Denison) Characteristics Seat valves series D4S are designed for directional control functions. A large variety of poppets, springs and covers - including shuttle valves, stroke limiters, solenoid valves (VV01)

More information

Pilot-Operated Proportional DC Valve Series D*1FH

Pilot-Operated Proportional DC Valve Series D*1FH Characteristics The pilot-operated proportional DC valves series of the D*1FH series are high-performance valves with electronic spool position feedback. These valves are available in sizes NG10 to NG2

More information

Proportional Pressure Reducing Valves Series PE*W (Parker), R4R (Denison)

Proportional Pressure Reducing Valves Series PE*W (Parker), R4R (Denison) Characteristics / Technical Data Series PE*W (Parker), RR (Denison) Subplate mounted proportional pressure reducing valves are available with both Parker (series PE*W) and Denison (series RR) model codes.

More information

Pilot Operated Proportional DC Valve Series D*1FW / D*1FT

Pilot Operated Proportional DC Valve Series D*1FW / D*1FT Characteristics The D*1FW / D*1FT pilot-operated proportional DC valves are available in NG10 (CETOP5), NG16 (CETOP7) and NG25 (CETOP8). These valves (D*1FW) are controlled electrically with the external

More information

Chapter 6: Check Valves

Chapter 6: Check Valves Contents Chapter : Check Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 0 10 1 25 32 Subplate Screw-in Slip-in SSR RK / RB CS SPZBE SPV / SPZ C4V CPS C4V D4S

More information

Chapter 6: Check Valves

Chapter 6: Check Valves Contents Chapter : Check Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 0 10 1 25 32 Subplate Screw-in Slip-in Shuttle valves SSR -2 Check valves, direct operated

More information

Symbol RH F... GENERAL DESCRIPTION. 4/3- and 4/2- way directional control valves with solenoid operation, heavy duty construction

Symbol RH F... GENERAL DESCRIPTION. 4/3- and 4/2- way directional control valves with solenoid operation, heavy duty construction GENERAL DESCRIPTION List: RH06-1F-1-July 016 4/3- and 4/- way directional control valves with solenoid operation, heavy duty construction Removable AC and DC voltage coils-quick replacement and rotation

More information

Proportional Pressure Relief Valve Series RE*T

Proportional Pressure Relief Valve Series RE*T Characteristics The pressure relief valve series RE*T have a proportional solenoid operated pilot stage with integrated electronics and a cartridge main stage. Features Pilot-operated pressure relief valve

More information

Explosion-Proof Valves. According to Directive 94/9/EC (ATEX) and IECEx Requirements

Explosion-Proof Valves. According to Directive 94/9/EC (ATEX) and IECEx Requirements Explosion-Proof Valves ccording to Directive 94/9/EC (EX) and IECEx Requirements WRNING USER RESPONSIILIY FILURE OR IMPROPER SELECION OR IMPROPER USE OF HE PRODUCS DESCRIED HEREIN OR RELED IEMS CN CUSE

More information

4/3, 4/2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid

4/3, 4/2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid 01/08 /3, /2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid 2.1 Type WE 10...L5X Size (NG) 10 Up to 350 bar Up to 150 L/min Contents Function and configurations -03 Specifications 0 Symbols 05

More information

DIRECTIONAL CONTROL VALVES CETOP3

DIRECTIONAL CONTROL VALVES CETOP3 DIRECTIONAL CONTROL VALVES CETOP3 GENERAL DESCRIPTION RH0...1-...F... Document: DCVC3-1-Aug 2013 4/3- and 4/2- way directional control valves with solenoid operation, heavy duty construction RH0...1-...F...

More information

DIRECTIONAL CONTROL VALVES CETOP3

DIRECTIONAL CONTROL VALVES CETOP3 DIRECTIONAL CONTROL VALVES CETOP3 CONTENTS: RH06...1 - electrical control... RH06...2 - hydraulic control... Page 1/17...7/17 8/17...9/17 RH06...4 - mechanical control RH06...6 - pneumatic control......

More information

Chapter 10: Valves for Pipe Mounting

Chapter 10: Valves for Pipe Mounting Contents Chapter : Valves for Pipe Mounting Series Description Size Body Page DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 1¼ 1½ 2 L-port T-port Pressure valves, manual operation R4V R4R Pressure relief function Pressure

More information

Proportional Directional Control Valves Series D*1FE. General Description. Features. D41FE Standard

Proportional Directional Control Valves Series D*1FE. General Description. Features. D41FE Standard Technical Information General Description pilot operated proportional valves are designed for high precision applications that require a safe middle position of the main spool at power down. The pilot

More information

Pressure Compensator Valves Series R5P (SAE Flange Mounted) General Description. Features

Pressure Compensator Valves Series R5P (SAE Flange Mounted) General Description. Features Technical Information General Description Series R5P direct operated, 3-way pressure compensators can be combined with any type of fixed or adjustable flow resistor (throttle) to provide a load compensated

More information

Chapter 7: Sandwich Valves

Chapter 7: Sandwich Valves Contents Chapter : Sandwich Valves Series Description Size Page DIN / ISO 06 10 16 25 DC valve Z1DW Shut-off valve -2 Pressure relief valves, manual operation RDM RM ZDV PRDM PRM ZDR Direct operated Pilot

More information

Throttle Check Valve Series FM

Throttle Check Valve Series FM Characteristics Double-throttle check valves from the Parker Manapak series FM are in sandwich design for easy configuration of stack systems. Throttle and check valves are located in ports A and B. FM2

More information

Pressure Control Valves. General Description. Specifications. Ordering Information

Pressure Control Valves. General Description. Specifications. Ordering Information Catalog HY14-3000/US Technical Information Control Valves Series RCP General escription Series RCP in-line pressure control valves are chiefly used as remote control valves. They limit system pressure

More information

RPEW4-10. Functional Description HA /2012. Solenoid Operated Directional Control Valves with Wirebox. Replaces HA /2006

RPEW4-10. Functional Description HA /2012. Solenoid Operated Directional Control Valves with Wirebox. Replaces HA /2006 Solenoid Operated Directional Control Valves with Wirebox RPEW-10 5/2012 Size 10 (D 05) 350 bar (5076 PSI) 10 L/min (37 GPM ) Replaces 2/2006 /3, /2 way directional control valves Four-land spool - reduced

More information

Introduction. Pressure drops

Introduction. Pressure drops Directional control valves CETOP 5/NG0 Introduction The ARON directional control valves NG0 designed for subplate mounting with an interface in accordance with UNI ISO 440-05 - 04-0 - 94 standard (ex CETOP

More information

Proportional Directional Control Valves Series D*1FB. General Description. Features D91FB OBE

Proportional Directional Control Valves Series D*1FB. General Description. Features D91FB OBE Technical Information Series D*1FB General Description Series D*1FB pilot operated proportional directional valves come in 4 sizes: D31FB NG10 (CETOP 5) D41FB NG16 (CETOP 7) D91FB NG25 (CETOP 8) D111FB

More information

Q max 300 l/min. Fluid temperature range C Fluid viscosity range cst Recommended viscosity cst 25

Q max 300 l/min. Fluid temperature range C Fluid viscosity range cst Recommended viscosity cst 25 41 420/103 ED DSP7 PILOT OPERATED DISTRIBUTOR SOLENOID OR HYDRAULIC(DSC7) CONTROLLED SERIES 10 CETOP 07 p max (see performance ratings table) Q max 300 l/min MOUNTING INTERFACE CETOP 4.2-4-07-320 The DSP7

More information

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007 Directional Control Valves Solenoid Operated RPE3-04 Size 04 (D 02) 320 bar (4600 PSI) 30 L/min (8.0 GPM) 10/2010 Replaces 12/2007 4/3-, 4/2- way directional control valves with solenoid control Solenoids

More information

Directional Control Valves Series D111VW. General Description. Features. Performance Curves

Directional Control Valves Series D111VW. General Description. Features. Performance Curves Technical Information General valves are piloted by a D1VW valve. The valves can be ordered with position control. The minimum pilot pressure must be ensured for all operating conditions of the directional

More information

DIRECTIONAL CONTROL VALVES CETOP 3/NG6

DIRECTIONAL CONTROL VALVES CETOP 3/NG6 CETOP 3/NG06 STANDARD SPOOLS CH. I PAGE 0 AD.3.E... CH. I PAGE AD.3.E...J* CH. I PAGE 2 AD3.XS... CH. I PAGE 3 AD3.XD... CH. I PAGE 4 AD.3.V... CH. I PAGE 5 AD.3.L... CH. I PAGE 6 OTHER OPERATOR CH. I

More information

Q max (see specifications table)

Q max (see specifications table) 41 260/103 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVES EXPLOSION-PROOF VERSION EEx-dIIC SERIES 20 MD1K CETOP 03 E4P4K CETOP P05 E07P4K CETOP 07 E5P4K CETOP 08 E10P4K CETOP 10 p max (see specifications

More information

DSH* /117 ED LEVER OPERATED DIRECTIONAL CONTROL VALVE MOUNTING SURFACES DSH3 ISO DSH5 ISO

DSH* /117 ED LEVER OPERATED DIRECTIONAL CONTROL VALVE MOUNTING SURFACES DSH3 ISO DSH5 ISO 41 600/117 ED DSH* LEVER OPERATED DIRECTIONAL CONTROL VALVE MOUNTING SURFACES DSH3 ISO 4401-03 DSH5 ISO 4401-05 p max (see performances table) Q nom (see performances table) OPERATING PRINCIPLE The DSH

More information

Chapter 5: Flow Valves

Chapter 5: Flow Valves Contents Chapter 5: Flow Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/4 3/8 1/2 3/4 1 0 10 1 Subplate Screw-in Throttle valves, manual adjustment MVI 5-3 NS 5-5 FS With free

More information

DL /118 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO p max 280 bar Q max 50 l/min

DL /118 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO p max 280 bar Q max 50 l/min 41 211/118 ED DL3 SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO 4401-03 p max 280 bar Q max 50 l/min MOUNTING SURFACE OPERATING PRINCIPLE ISO 4401-03-02-0-05 (CETOP

More information

Directional Control Valves. General Description. Features. Specifications

Directional Control Valves. General Description. Features. Specifications Technical Information General Description directional control valves are high-performance, 4-chamber, direct operated, wet armature, solenoid controlled, 3 or 4-way valves. They are available in 2 or 3-position

More information

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US Industrial Hydraulic Valves irectional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories Catalog HY14-25/US Industrial Hydraulic Valves WARNING USER RESPONSIBILITY FAILURE OR IMPROPER

More information

RPEH4-16. Functional Description HA / /2 and 4/3 Way Directional Control Valves Pilot Operated. Replaces HA /2002

RPEH4-16. Functional Description HA / /2 and 4/3 Way Directional Control Valves Pilot Operated. Replaces HA /2002 4/2 and 4/3 Way Directional Control Valves Pilot Operated RPEH4-16 HA 4023 2/2003 Size 16 p max up to 320 bar Q max up to 300 L/min Replaces HA 4023 2/2002 Solenoid pilot operated directional valves (RPEH)

More information

Chapter 3: Proportional DC Valves

Chapter 3: Proportional DC Valves Catalogue HY11-5/UK Contents Chapter : Proportional DC Valves Series Description Size DIN/ISO direct pilot Operation Electronics external onboard LVDT Spool Design Page Overlap Zero lap Spool/ Sleeve Introduction

More information

Chapter 5: Flow Valves

Chapter 5: Flow Valves Catalogue HY11-300/UK Contents Chapter : Flow Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/4 3/8 1/2 3/4 1 06 10 16 Throttle valves, manual adjustment MVI -2 NS -4 FS With free

More information

PRM2-06. Functional Description HA /2014. Proportional Directional Control Valves. Replaces HA /2013. Size 06 p max 350 bar Q max 40 L/min

PRM2-06. Functional Description HA /2014. Proportional Directional Control Valves. Replaces HA /2013. Size 06 p max 350 bar Q max 40 L/min Proportional Directional Control Valves Size 06 p max 50 bar Q max 40 L/min PRM-06 HA 5104 /014 Replaces HA 5104 /01 Compact design with integrated High reliability Simple replacement of the exciting coils

More information

D4D SOLENOID OPERATED DIRECTIONAL CONTROL VALVES DIRECT CURRENT - SERIES 50 ALTERNATING CURRENT - SERIES 60

D4D SOLENOID OPERATED DIRECTIONAL CONTROL VALVES DIRECT CURRENT - SERIES 50 ALTERNATING CURRENT - SERIES 60 41 300/198 ED D4D SOLENOID OPERATED DIRECTIONAL CONTROL VALVES DIRECT CURRENT - SERIES 0 ALTERNATING CURRENT - SERIES 60 CETOP 0 p max 30 bar Q max 100 l/min MOUNTING INTERFACE DIRECT-ACTING SOLENOID OPERATED

More information

NG6. Proportional adjustment. Manifold mounting acc. to ISO External drain. Main stage spool type valve. Pilot stage seated type valve.

NG6. Proportional adjustment. Manifold mounting acc. to ISO External drain. Main stage spool type valve. Pilot stage seated type valve. Catalog HY14-255/US Technical Information Series VY*K General Description Series VY*K pilot operated sequence valves feature proportional adjustment and an external drain. The external drain allows application

More information

p max (see table of performances) Q max (see table of performances) bar Maximum flow rate from port P to A - B - T l/min

p max (see table of performances) Q max (see table of performances) bar Maximum flow rate from port P to A - B - T l/min 41 400/117 ED E*P4 PILOT OPERATED DISTRIBUTOR SOLENOID OR HYDRAULIC (C*P4) CONTROLLED E4P4 CETOP P05 E4R4 ISO 4401-05 E5 ISO 4401-08 p max (see table of performances) Q max (see table of performances)

More information

4/3, 4/2 proportional directional valves solenoid operated (for open loop control)

4/3, 4/2 proportional directional valves solenoid operated (for open loop control) /, / proportional directional valves solenoid operated (for open loop control) RE -/7. Replaces: RE7/.7 / Type L (LCP) Size Series Maximum operating pressure bar [ psi] Nominal flow rated l/min [.7 gpm]

More information

4/3, 4/2 and 3/2 explosion-proof solenoid directional valve

4/3, 4/2 and 3/2 explosion-proof solenoid directional valve 01/06 4/3, 4/2 and 3/2 explosion-proof solenoid directional valve Type G...WE10...L3X 2.22 Size (NG) 10 Up to 315 bar Up to 120 L/min Contents Function and configuration Specifications 03 Spool symbols

More information

RNEH4-25. Functional Description HA / /2 and 4/3 Way Directional Control Valves Pilot Operated. Replaces HA /2012

RNEH4-25. Functional Description HA / /2 and 4/3 Way Directional Control Valves Pilot Operated. Replaces HA /2012 4/2 and 4/3 Way Directional Control Valves Pilot Operated RNEH4-25 HA 4024 7/2015 Size 25 (D 08) 320 bar (4600 PSI) 600 L/min (159 GPM) Replaces HA 4024 6/2012 Solenoid pilot operated directional valves

More information

Series PD directly operated solenoid valves

Series PD directly operated solenoid valves > Series PD solenoid valves CATALOGUE > Release 8.8 Series PD directly operated solenoid valves /-way - Normally Closed (NC) Please note that all Series PD solenoid valves are supplied with direct current

More information

Série D3 Válvula Direcional CETOP 5 e NG 10. Catálogo HY /US

Série D3 Válvula Direcional CETOP 5 e NG 10. Catálogo HY /US Série D3 Válvula Direcional CETOP 5 e NG 10 Catálogo HY14-2502/US Catalog HY14-2502/US Introduction pplication Series D3 hydraulic directional control valves are high performance, direct operated 4-way

More information

Chapter 3: Proportional DC Valves

Chapter 3: Proportional DC Valves Catalogue HY11-5/UK Contents Chapter : Proportional DC Valves Series Description Size Operation Electronics LVDT Spool Design Page DIN/ISO direct pilot external onboard Overlap Zero lap Spool/ Sleeve Introduction

More information

4/3-4/2 Proportional directional valves L5080 solenoid (LC04P) operated (for open loop control) L5080 (LC04P)

4/3-4/2 Proportional directional valves L5080 solenoid (LC04P) operated (for open loop control) L5080 (LC04P) / - / Proportional directional valves L solenoid (LCP) operated (for open loop control) L (LCP) RE - Edition:. Replaces: 7. 7. Size Series Maximum operating pressure bar ( psi) Maximum flow l/min (.7 gpm)

More information

RPEW4-06. Functional Description HA /2005. Solenoid Operated Directional Control Valves with Wirebox 1/2 NPT 1/2 NPT. Replaces HA /2004

RPEW4-06. Functional Description HA /2005. Solenoid Operated Directional Control Valves with Wirebox 1/2 NPT 1/2 NPT. Replaces HA /2004 Solenoid Operated Directional Control Valves with Wirebox RPEW4-06 2/2005 Size 06 p max up to 320 bar Q max up to 80 L/min Replaces 2/2004 4/3, 4/2 way directional control valves Four-land spool - reduced

More information

ZRV. Direct Operated Check Valve Series ZRV (Denison)

ZRV. Direct Operated Check Valve Series ZRV (Denison) Characteristics / Ordering Code Direct Operated Check Valve Series ZRV (Denison) Direct operated check valves series ZRV have a cartridge type insert to provide zero leakage and high life time. he check

More information

Publ. 3-EN 2950-A. DENISON HYDRAULICS Pressure Relief Valve R6V

Publ. 3-EN 2950-A. DENISON HYDRAULICS Pressure Relief Valve R6V Publ. 3-EN 2950-A DENISON HYDRAULICS Pressure Relief Valve R6V FEATURES, SYMBOL FEATURES High Performance: R6V valves are designed for a maximum pressure of 350 bar and a flow capacity up to 650 l/min.

More information

DL /116 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SERIES 10 SUBPLATE MOUNTING ISO p max 320 bar Q max 125 l/min

DL /116 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SERIES 10 SUBPLATE MOUNTING ISO p max 320 bar Q max 125 l/min 41 330/116 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO 4401-05 p max 320 bar Q max 125 l/min MOUNTING INTERFACE OPERATING PRINCIPLE ISO 4401-05-04-0-05 (CETOP 4.2-4-05-320)

More information

Cartridge Valves Technical Information Directional Valves DCV 03

Cartridge Valves Technical Information Directional Valves DCV 03 OVERVIEW DCV 03 directional control valves consist of: housing (1), control spool (5), with two centering springs (4), and cylindrical operating solenoids (2, 3). The three-position directional valves

More information

RPE3-04. Functional Description HA /2013. Directional Control Valves Solenoid Operated. Replaces HA /2010

RPE3-04. Functional Description HA /2013. Directional Control Valves Solenoid Operated. Replaces HA /2010 Directional Control Valves Solenoid Operated RPE3-04 Size 04 (D 02) 320 bar (4600 PSI) 30 L/min (8.0 GPM) HA 4014 09/2013 Replaces HA 4014 10/2010 4/3-, 4/2- way directional control valves with solenoid

More information

Series PD directly operated solenoid valves

Series PD directly operated solenoid valves > Series PD solenoid valves CATALOGUE > Release 8.7 Series PD directly operated solenoid valves New /-way Normally Closed (NC) Note: all Series PD /-way solenoid valves are basically in DC. To operate

More information

Directional Controls

Directional Controls Vickers Directional Controls Wet Armature Solenoid Operated Directional Control Valves Model DGV-, Series Typical Construction of a Spring-Centered DC Valve with Variable Speed Pilot Control passage Speed

More information

Seated valves. Type WV700 NG 6 ISO up to 25 l/min, up to 700 bar. Features. Applications. Design. Technical data

Seated valves. Type WV700 NG 6 ISO up to 25 l/min, up to 700 bar. Features. Applications. Design. Technical data Seated valves Type WV700 Features Direct operated Leakage free (double tight) High operational safety and reliable switching High duty cycles and long lifetime Applications Control of cylinders and motors

More information

DS5JB /110 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE. Q max 32 GPM ALTERNATING CURRENT SERIES 10

DS5JB /110 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE. Q max 32 GPM ALTERNATING CURRENT SERIES 10 41 320/110 ED DS5JB SOLENOID OPERATED DIRECTIONAL CONTROL VALVE ALTERNATING CURRENT NFPA D05 (ISO 4401-05 / CETOP 05) p max 4600 psi Q max 32 GPM MOUNTING INTERFACE NFPA D05 ISO 4401-05-0-04-05 (CETOP

More information

RPE2-04. Functional Description HA /2002. Solenoid Operated Directional Valves. Replaces HA /2000

RPE2-04. Functional Description HA /2002. Solenoid Operated Directional Valves. Replaces HA /2000 Solenoid Operated Directional Valves RPE2-04 HA 4012 3/2002 Size 04 p max up to 320 bar Q max up to 20 l/min Replaces HA 4012 6/2000 Special model - special installation dimensions 4/3-, 4/2- and 3/2-way

More information

General Specifications DRV DRV-Exm DRV-Exd

General Specifications DRV DRV-Exm DRV-Exd direct operated, 3-way pressure reducing valve Q max = 8 l/min pressure range = - 5 bar body stainless steel (optional) Description The proportional pressure reducing valve (3-way function) is used to

More information

Type of operation Depending on requirement either one or two dry DC-solenoid,

Type of operation Depending on requirement either one or two dry DC-solenoid, Features Leakage free High availability 100% duty cycle Porting NG 6 according to DIN 24340 Positive overlap Function and design The seated valves are direct operated. Depending on the desired control

More information

p max (see table of performances) Q max (see table of performances) bar Maximum flow l/min see par

p max (see table of performances) Q max (see table of performances) bar Maximum flow l/min see par 41 510/112 ED EXPLOSION-PROOF VERSION SOLENOID OPERATED DIRECTIONAL CONTROL VALVES in compliance with ATEX 94/9/EC MD1K ISO 4401-03 (CETOP 03) E4P4K CETOP P05 E07P4K ISO 4401-07 (CETOP 07) E5P4K ISO 4401-08

More information

VSNG10 - SOLENOID OPERATED DIRECTIONAL VALVES

VSNG10 - SOLENOID OPERATED DIRECTIONAL VALVES CONTINENTAL HYDRAULICS VSNG10 SOLENOID OPERATED DIRECTIONAL VALVES 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400 / WWW.CONTINENTALHYDRAULICS.COM VSNG10 SOLENOID OPERATED DIRECTIONAL VALVES

More information

DIRECTIONAL CONTROL VALVE SOLENOID OPERATED TYPE HD3-ES-*-/10 CETOP MPa HD3 - ES - (1) (C) - * - (024C) (-) / 10

DIRECTIONAL CONTROL VALVE SOLENOID OPERATED TYPE HD3-ES-*-/10 CETOP MPa HD3 - ES - (1) (C) - * - (024C) (-) / 10 table HD-0/ (07/0) DIRECTIONAL CONTROL VALVE SOLENOID OPERATED TYPE HD-ES-*-/0 CETOP 0-5 MPa /5 HOW TO READ THE MODEL CODE FOR HD-ES - Pressure 5 MPa (50 bar) HD - ES - () (C) - * - (0C) (-) / 0 5 6 7

More information

D4E DIRECT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 41

D4E DIRECT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 41 83 250/198 ED D4E DIRECT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SUBPLATE MOUNTING CETOP 05 p max 250 bar Q max (see performance ratings table) MOUNTING INTERFACE OPERATING

More information

DSE3B /118 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 10 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min

DSE3B /118 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 10 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min 83 215/118 ED DSE3B DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SUBPLATE MOUNTING ISO 4401-03 p max 350 bar Q max 40 l/min MOUNTING INTERFACE OPERATING PRINCIPLE ISO 4401-03-02-0-05 (CETOP 4.2-4-03-350)

More information

DSE /117 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 11 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min

DSE /117 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 11 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min 83 2/117 ED DSE3 DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SUBPLATE MOUNTING ISO 41-3 p max 3 bar Q max l/min MOUNTING SURFACE OPERATING PRINCIPLE ISO 41-3-2-- (CETOP 4.2-4-3-3). 33 3.2 21. 12.7.1.7

More information

Directional spool valves, direct operated, smoothly switching, with solenoid actuation

Directional spool valves, direct operated, smoothly switching, with solenoid actuation Directional spool valves, direct operated, smoothly switching, with solenoid actuation Type WE..73 A12 H7564 Features 4/2 or 4/3 directional design Porting pattern according to DIN 24340 form A Porting

More information

Seated valves 500 bar

Seated valves 500 bar Seated valves 500 bar Type WVM-6I Features Solenoid actuated and direct operated Leakage free in every direction (double tight) High operational safety and reliable switching High duty cycles and long

More information

40 l/min (11 GPM) p max

40 l/min (11 GPM) p max Proportional Directional Control Valve, with Analog Control Electronics PRM2-06 Functional Description Size 06 (D03) Q max 40 l/min (11 GPM) p max 350 bar (5100 PSI) Technical Features Direct acting, proportional

More information

SOLENOID VALVES AND PNEUMATIC VALVES

SOLENOID VALVES AND PNEUMATIC VALVES S E R I E S P Directly operated mini-solenoid valves Series P 3/ way N.C. or N.O. Ports M5 (for single base) Cartridge ø 3 and 4 (for manifold) Note: All the serie P electrovalves are basic in DC. For

More information

Series P directly operated solenoid valves

Series P directly operated solenoid valves > Series P solenoid valves CATALOGUE > Release 8.7 Series P directly operated solenoid valves 3/-way NC and NO. The solenoid valves can be mounted on a single base (with M5 ports) as well as on manifolds

More information

Proportional Pressure Reducing Valve Series D1FV

Proportional Pressure Reducing Valve Series D1FV Characteristics roportional ressure Reducing Valve Series D1FV he proportional pressure reducing valves series D1FV are available with and without onboard electronics (OE). D1FV OE he digital onboard electronics

More information

4/3-4/2 Directional valve with solenoid actuation

4/3-4/2 Directional valve with solenoid actuation 4/3-4/2 Directional valve with solenoid actuation RE 18305-08/12.13 1/10 L5110 LC1-Z ) Size NG6 ISO 4401-03 CETOP RP121 H-03 CETOP 3) Series 00 Maximum operating pressure 350 bar [5076 psi] Maximum flow

More information

VSD05M-S - SOLENOID OPERATED DIRECTIONAL ANTI-SHOCK VALVES

VSD05M-S - SOLENOID OPERATED DIRECTIONAL ANTI-SHOCK VALVES CONTINENTAL HYDRAULICS VSD05M-S SOLENOID OPERATED DIRECTIONAL ANTI-SHOCK VALVES 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400 / WWW.CONTINENTALHYDRAULICS.COM VSD05M-S SOLENOID OPERATED

More information

4/3 proportional directional control valve, without position control, with on-board electronics (OBE)

4/3 proportional directional control valve, without position control, with on-board electronics (OBE) 4/3 proportional directional control valve, without position control, with on-board electronics (OBE) Type 4WRBAE..E.. /..W.. Nominal size (NG) 6, 10 Unit series 2X Maximum working pressure P, A, B 315

More information

Proportional Throttle Valves Series TDL

Proportional Throttle Valves Series TDL Catalogue HY11-200/UK Characteristics Function Proportional throttle valves are designed to include three stages. The main valve poppet is controlled by a hydraulic follower. The position of the hydraulic

More information

NG06. General Size NG6 NG10 Design

NG06. General Size NG6 NG10 Design Catalog HY14-255/US Series VY*K General Series VY*K pilot operated sequence valves feature proportional adjustment and an external drain. The external drain allows application as both a sequence valve

More information

6/2 WAY DIRECTIONAL VALVE KV (NG 6)

6/2 WAY DIRECTIONAL VALVE KV (NG 6) 6/2 WAY DIRECTIONAL VALVE KV (NG 6) NG 6 Up to 350 bar [5 076 PSI] Up to 50 L/min [13.2 GPM] Plug-in connector for solenoids to ISO 4400. Threaded connections to ISO 9974 (Metric), ISO 1179 (BSPP/Gas),

More information

Proportional cartridge throttle valve, with inductive position transducer, pilot operated

Proportional cartridge throttle valve, with inductive position transducer, pilot operated Proportional cartridge throttle valve, with inductive position transducer, pilot operated RE 29215/09.05 1/18 Type FESX Nominal size 16, 25, 32, 40, 50 Unit series 1X Maximum working pressure A, B, X 315

More information

DENISON HYDRAULICS High Flow Seat Valve Cartridges CEHFE, C1C

DENISON HYDRAULICS High Flow Seat Valve Cartridges CEHFE, C1C DENISON HYDRAULICS High Flow Seat Valve Cartridges CEHFE, C1C 2/2-Way Function / Cavity conform to ISO 7368 (DIN 24342) Publ. 7 EN 5060 A FEATURES, DESCRIPTION FEATURES x High flow cartridges give highest

More information

Proportional cartridge throttle valve, with on-board electronics (OBE) and inductive position transducer, pilot operated

Proportional cartridge throttle valve, with on-board electronics (OBE) and inductive position transducer, pilot operated Proportional cartridge throttle valve, with on-board electronics (OBE) and inductive position transducer, pilot operated RE 29216/09.05 1/18 Type FESE Nominal size 16, 25, 32, 40, 50 Unit series 1 Maximum

More information

Vickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi)

Vickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi) Vickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi) Revised 2/93 GB C 2037 Table of Contents Model Code...................................................................................................

More information

Directional Control Valves, electrically operated Type WE 5 Huade América 1

Directional Control Valves, electrically operated Type WE 5 Huade América 1 Directional Control Valves, electrically operated Type WE 5 Huade América 1 BEIJING HUADE HYDRAULIC INDUSTRIAL GROUP CO.,LTD. Directional control valves, electrically operated Type WE 5 Size5 up to 25

More information

unrestricted; preferably with coil at bottom (auto. air bleed) 12 or 24 Volt DC from an electronic controller Deutsch plug - IP67

unrestricted; preferably with coil at bottom (auto. air bleed) 12 or 24 Volt DC from an electronic controller Deutsch plug - IP67 3 Technical data General characteristics Design Flow direction Seals De-energized position Mounting attitude Description, value, unit line mounting P A controlled P R surplus flow discharge (models shown

More information

MD1JB SOLENOID OPERATED DIRECTIONAL CONTROL VALVES

MD1JB SOLENOID OPERATED DIRECTIONAL CONTROL VALVES 41 230/102 AD MD1JB SOLENOID OPERATED DIRECTIONAL CONTROL VALVES ALTERNATING CURRENT NFPA D03 (CETOP 03) p max 5,000 psi Q max 18 GPM MOUNTING INTERFACE OPERATING PRINCIPLE NFPA D03 CETOP 4.2-4-03-350

More information

EV FT3 ES-FT5 ES/GB :09 Pagina 4 FT3 ES* 4

EV FT3 ES-FT5 ES/GB :09 Pagina 4 FT3 ES* 4 EV FT3 ES-FT5 ES/GB 4 15-07-2008 16:09 Pagina 4 5 1 HOW TO READ THE MODEL CODE FOR VALVES FT3 - ES - * FT3 - ES - (1) (C) - * - (024C) / 10 2 FUNCTIONAL SYMBOLS 1C 1N 1 2 3 4 5 6 7 1 FT3 4-way directional

More information

SOLENOID DIRECTIONAL VALVE

SOLENOID DIRECTIONAL VALVE SOLENOID DIRECTIONAL VALVE type DHE direct operated, high performances, ISO 4401 dimensione 06 Spool type, two or three position direct operated valves with high performance threaded solenoids certified

More information

BW0511FP. ByWire Elements BW0511FP Flow Sharing Element Interface IBW0511

BW0511FP. ByWire Elements BW0511FP Flow Sharing Element Interface IBW0511 ywire Elements Flow Sharing Element Interface IW05 efore use, carefully read the GENERL INSTRUCTIONS FOR USE OF DIRECTIONL CONTROL VLVES Technical data Nominal flow Nominal pressure 35 l/min - P=8 bar

More information

3/2-way Solenoid Valve for pneumatics

3/2-way Solenoid Valve for pneumatics 656 3/-way Solenoid Valve for pneumatics Compact design Single and manifold mounting Low power consumption Rocker pilot in DC Type 656 can be combined with... Fast response times Type 506 Type 510/511

More information

20 l/min (5 GPM) p max. Technical Features

20 l/min (5 GPM) p max. Technical Features Proportional Directional Control Valve, with Analogue Control Electronics PRM2-0 Functional Description Size 0 (D02) Q max 20 l/min (5 GPM) p max 320 bar (600 PSI) Technical Features Direct acting, proportional

More information

VS6M - SOLENOID OPERATED DIRECTIONAL VALVES

VS6M - SOLENOID OPERATED DIRECTIONAL VALVES CONTINENTAL HYDRAULICS VS6M SOLENOID OPERATED DIRECTIONAL VALVES 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400 / WWW.CONTINENTALHYDRAULICS.COM VS6M SOLENOID OPERATED DIRECTIONAL VALVES

More information

Flow Control Valve. 1 Description. 2 Symbols. Series SRCA General. 1.2 Application examples way flow control way flow control

Flow Control Valve. 1 Description. 2 Symbols. Series SRCA General. 1.2 Application examples way flow control way flow control Flow Control Valve Series SRC.. plug-in coil for easy coil change flow rates are unaffected by changes in temperature or load. compact reduced p ZnNi coating (>70h DIN EN ISO 97 NSS) Description. General

More information