Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Size: px
Start display at page:

Download "Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US"

Transcription

1 Industrial Hydraulic Valves Directional Control, ressure Control, Sandwich, Subplates & Manifolds, ccessories Catalog HY /US

2 Industrial Hydraulic Valves WRNING USER RESONSIILIY FILURE OR IMROER SELECION OR IMROER USE OF HE RODUCS DESCRIED HEREIN OR RELED IEMS CN CUSE DEH, ERSONL INJURY ND ROERY DMGE. his document and other information from arker-hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise. he user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. he user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from arker or its subsidiaries or authorized distributors. o the extent that arker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems. OFFER OF SLE he items described in this document are hereby offered for sale by arker-hannifin Corporation, its subsidiaries or its authorized distributors. his offer and its acceptance are governed by the provisions stated in the detailed Offer of Sale elsewhere in this document or available at SFEY GUIDE For safety information, see Safety Guide SG HY at or call Carker. Copyright 2011, ll Rights Reserved Cat HY frtcvr.indd, dd II Elyria, Ohio, US

3 Contents Series D1V (NF D03/CEO 3, NG6 Mounting) Introduction and echnical Information Series D1V... Solenoid Operated ccessories Series D1V and D1V... ir and Oil ilot Operated Series D1VC, D1VD and D1VG... Cam and Cam Lever Operated Series D1VL... Lever Operated Installation... Series D1V Series D1SE (NF D03/CEO 3, NG6 Mounting) Series D1SE... Solenoid Operated Series D3 (NF D05/CEO 5, NG10 Mounting) Introduction and echnical Information Series D3W... Solenoid Operated ccesories Series D3DW... Solenoid Operated Series D3... ir Operated Series D3C and D3D... Cam Operated Series D3L... Lever Operated Installation... Series D Series D31 (NF D05H/CEO 5H, NG10 Mounting) Introduction and echnical Information Series D31... ilot Operated, Solenoid Controlled ccessories Series D31NW... ilot Operated, Solenoid Controlled ccessories Series D31*... ir ilot Operated Series D31*L... Lever Operated Series D3... Oil ilot Operated Installation... Series D31, D Series D41 (NF D07/CEO 7, NG16 Mounting) Introduction and echnical Information Series D41VW... ilot Operated, Solenoid Controlled ccessories Series D4L... Lever Operated Series D4... Oil ilot Operated Installation... Series D Series D61 (NF D08/CEO 8, NG25 Mounting) Introduction and echnical Information Series D61V... ilot Operated, Solenoid Controlled ccessories Series D61V... ir ilot Operated Series D61VL... Lever Operated Series D6... Oil ilot Operated Installation... Series D61, D Series D81 (NF D08/CEO 8, NG25 Mounting) Introduction and echnical Information Series D81V... ilot Operated, Solenoid Controlled ccessories Series D81V... ir ilot Operated Series D81VL... Lever Operated Series D8... Oil ilot Operated Installation... Series D81, D Series D9L... Lever Operated Series D101 (NF D10/CEO 10, NG32 Mounting) Introduction and echnical Information Series D101V... ilot Operated, Solenoid Controlled ccessories Series D101V... ir ilot Operated Series D101VL... Lever Operated Series D10... Oil ilot Operated Installation... Series D101, D Series D111 (NF D10/CEO 10, NG32 Mounting) Series D111VW... ilot Operated, Solenoid Controlled Installation Series D4S (NG10, NG25, NG32) Series D4S... Directional Seat Valve Series D5S (SE Flange) Series D5S... Directional Seat Valve, SE Flange D1.indd, dd 1 Elyria, Ohio, US

4 Catalog HY /US Introduction pplication Series D1V hydraulic directional control valves are high performance, direct operated 4-way valves. hey are available in 2 or 3-position styles. hey are manifold mounted valves, which conform to NF s D03, CEO 3 mounting pattern. hese valves were designed for industrial and mobile hydraulic applications which require high cycle rates, long life and high efficiency. Series D1V Operation Series D1V directional control valves consist of a 4-chamber style body, and a case hardened sliding spool. he spool is directly shifted by a variety of operators including: solenoid, lever, cam, air or oil pilots. D1VW Solenoid Operated lug-in Conduit ox Style Easy access mounting bolts. Waterproof NEM 4, I67. No tools required for coil removal. 19 standard spool styles available. Four electrical connection options. Lights included (CS approval for DC solenoids and lights). Easy coil replacement. lug-in design offered with lights & other options. D1VW Solenoid Operated Hirschmann (DIN) Style DIN Style (43650) Hirschmann. 19 spool styles available. No tools required for coil removal. Easy coil replacement. C & DC lights available. (CS approval for solenoids and lights). D1V Oil ilot Operated Subplate pilot or end cap pilot option. ilot pressure: 15.2 ar (220 SI) to 207 ar (3000 SI). D1.indd, dd 2 Elyria, Ohio, US

5 Introduction Series D1V Electrical Connections Series D1V valves may be configured in all popular electrical configurations including: lug-in Conduit ox DESIN (DC only) Deutsch (DC only) Explosion roof Hirschmann (DIN) Metri-ack (DC only) Dual Spade (DC only) Wire Lead Conduit ox D1VW Solenoid Operated Wire Lead Conduit ox Style Easy access mounting bolts. Waterproof NEM 4, I67. No tools required for coil removal. 19 spool styles available. No lights available D1VW Solenoid Operated DESIN Style Surge suppression standard. 19 standard spool available. No tools required for spool removal. Easy coil replacement. Wired to DESIN Spec (VDM). Lights included. D1VW Solenoid Operated Dual Spade Style Dual spade connection (SE Style 1). Easy coil replacement. Surge suppression available. 19 standard spool styles available. D1.indd, dd 3 Elyria, Ohio, US

6 Catalog HY /US Introduction Features Easy access mounting bolts. 345 ar (5000 SI) pressure rating. Flows to 22 GM depending on spool. Choice of five operator styles. Rugged four land spools. Series D1V Low pressure drop. hosphate finished body. CS approved and U.L. recognized available. Optional proportional spool available. Optional painted body. D1VL Lever Operated Spring return or detent styles available. Heavy duty handle design. D1V ir Operated Low pilot pressure required 4.1 ar (60 SI) minimum. D1VC Cam Operated Choice of 2 cam roller positions (D1VC and D1VD). wo styles available (D1VC and D1VG). Short stroke option. D1.indd, dd 4 Elyria, Ohio, US

7 Introduction Series D1V D1VW C Solenoid Operated Soft Shift 4 standard orifice sizes available. 19 spool styles available. C Rectified or DC input. D1VW DC Solenoid Operated Soft Shift D1.indd, dd 5 Elyria, Ohio, US

8 echnical Information Series D1V Standard Spool Reference Data Maximum Flow, LM (GM) 350 ar (5000 SI) w/o Malfunction High Watt Low Watt Low Watt Model Spool Symbol DC C DC D1V* (20) 49 (13) 37 (10) D1V* (20) 45 (12) 68 (18) D1V* (18) 30 (8) 34 (9) D1V* (10) 30 (8) 68 (18) D1V* (16) 45 (12) 45 (12) D1V* (21) 49 (13) 52 (14) D1V* (12) 18 (5) 18 (5) D1V* (13) 45 (12) 37 (10) D1V* (15) 45 (12) 45 (12) D1V* (4) 11 (3) 15 (4) D1V* (16) 30 (8) 37 (10) D1V* (12) 18 (5) 18 (5) D1V* (21) 30 (8) 34 (9) D1V* (16) 45 (12) 52 (14) D1V* (20) 45 (12) 75 (20) D1V* (10) 11 (3) 7 (2) D1V* (18) 18 (5) 75 (20) D1V* (9) 26 (7) 30 (8) D1V* (9) 26 (7) 34 (9) Center or De-energized position is indicated by,, & port notation. D1.indd, dd 6 Elyria, Ohio, US

9 echnical Information Series D1V D1V, D1V, D1VC, D1VL Reference Data Maximum Flow, LM (GM) 350 ar (5000 SI) Model Spool Symbol w/o Malfunction D1V*1 83 (22) D1V*2 83 (22) D1V*4 45 (12) D1V*8 45 (12) D1V*9 57 (15) Center or De-energized position is indicated by,, & port notation. # D1V only. Maximum Flow, LM (GM) 350 ar (5000 SI) Model Spool Symbol w/o Malfunction D1V*20 # 53 (14) D1V*26 # 11 (3) D1V*30 # 19 (5) D1V*81 30 (8) D1V*82 30 (8) Manaplug Electrical Mini lug E in lug E in lug (Double Solenoid) E in lug (Single Solenoid) Manaplug Electrical Micro lug E in lug E in lug (Double Solenoid) E in lug (Single Solenoid) Desina 12mm Connector Monitor Switch Connector N Electrical Cords Mini lug EC EC3 EC12 EC5 EC53 EC512 3 Conductor, 6 ft. 3 Conductor, 3 ft. 3 Conductor, 12 ft. 5 Conductor, 6 ft. 5 Conductor, 3 ft. 5 Conductor, 12 ft. Hirschmann Female Connector Gray (Solenoid ) lack (Solenoid ) 1 1 Hirschmann Female Connector-Rectified ( VC) Gray (Solenoid ) lack (Solenoid ) 1 1 Hirschmann Female Connector-Rectified w/lights ( VC) Hirschmann Female Connector w/lights (Note Voltages) Quantity Required,C,D,E,F H,K,M VC or VDC VDC, VC D1.indd, dd 7 Elyria, Ohio, US

10 Catalog HY /US echnical Information Solenoid Ratings Insulation System llowable Deviation from rated voltage rmature CS File Number Environmental Capability Class F -15% to +10% for DC and C rectified coils -5% to +5% for C Coils Wet pin type LR60407 DC Solenoids meet NEM 4 and I67 when properly wired and installed. Contact HVD for C coil applications. Series D1V Explosion roof Solenoid Ratings* U.L. & CS (EU) Class I, Div 1 & 2, Groups C & D Class II, Div 1 & 2, Groups E, F & G s defined by the N.E.C. MSH (EO) Complies with 30CFR, art 18 EX (ED) Complies with EX requirements for: Exd, Group II; EN50014: mds. 1 & 2, EN50018: 2000 EX & CS/US (E) Complies with EX EN , EN Ex d IIC; CS/US Ex d IIC, Ex d IIC for Class I, Zone 1, UL1203, UL1604, CS E61241,1 Class II, Div 1 * llowable Voltage Deviation ±10%. Note that Explosion roof C coils are single frequency only. Code Voltage In Rush mps In Rush Holding mps Watts Resistance Voltage ower mperage 3MM Code Code D L 120 VDC N/ N/ 0.09 mps 10 W ohms D Omit 120 VDC N/ N/ 0.26 mps 30 W ohms G Omit 198 VDC N/ N/ 0.15 mps 30 W ohms J L 24 VDC N/ N/ 0.44 mps 10 W ohms J Omit 24 VDC N/ N/ 1.32 mps 30 W ohms K L 12 VDC N/ N/ 0.88 mps 10 W ohms K Omit 12 VDC N/ N/ 2.64 mps 30 W 4.32 ohms L L 6 VDC N/ N/ 1.67 mps 10 W 3.59 ohms L Omit 6 VDC N/ N/ 5.00 mps 30 W 1.20 ohms Q Omit 100 VC / 60 Hz 2.05 mps 170 V 0.77 mps 30 W ohms QD F 100 VC / 60 Hz 1.35 mps 135 V 0.41 mps 18 W ohms QD F 100 VC / 50 Hz 1.50 mps 150 V 0.57 mps 24 W ohms R F 24/60 VC, Low Watt 6.67 mps 160 V 2.20 mps 23 W 1.52 ohms Omit 240/60 VC 0.83 mps 199 V 0.30 mps 30 W ohms Omit 220/50 VC 0.87 mps 191 V 0.34 mps 30 W ohms F 240/60 VC, Low Watt 0.70 mps 168 V 0.22 mps 21 W ohms F 220/50 VC, Low Watt 0.75 mps 165 V 0.26 mps 23 W ohms U L 98 VDC N/ N/ 0.10 mps 10 W ohms U Omit 98 VDC N/ N/ 0.31 mps 30W ohms Y Omit 120/60 VC 1.7 mps 204 V 0.60 mps 30 W ohms Y Omit 110/50 VC 1.7 mps 187 V 0.68 mps 30 W ohms Y F 120/60 VC, Low Watt 1.40 mps 168 V 0.42 mps 21 W ohms Y F 110/50 VC, Low Watt 1.50 mps 165 V 0.50 mps 23 W ohms Z L 250 VDC N/ N/ 0.04 mps 10 W ohms Z Omit 250 VDC N/ N/ 0.13 mps 30 W ohms Explosion roof Solenoids R 24/60 VC 7.63 mps 183 V 2.85 mps 27 W 1.99 ohms 240/60 VC 0.76 mps 183 V 0.29 mps 27 W 1.34 ohms N 220/50 VC 0.77 mps 169 V 0.31 mps 27 W 1.38 ohms Y 120/60 VC 1.60 mps 192 V 0.58 mps 27 W ohms 110/50 VC 1.47 mps 162 V 0.57 mps 27 W ohms K 12 VDC N/ N/ 2.75 mps 33 W 4.36 ohms J 24 VDC N/ N/ 1.38 mps 33 W ohms "E" Explosion roof Solenoids K 12 VDC N/ N/ 1.00 mps 12 W ohms J 24 VDC N/ N/ 1.00 mps 13 W ohms Y 120/60-50 VC N/ N/ 0.16 mps 17 W ohms D1.indd, dd 8 Elyria, Ohio, US

11 erformance Curves Series D1V D1V Shift Limits, DC & C Rectified 30 Watt Example: Determine the maximum allowable flow of a Series D1V valve (#004 spool) at 138 ar (2000 SI) supply pressure. Locate the curve marked 004. t 138 ar (2000 SI) supply pressure, the maximum flow is 57 LM (15 GM). t 207 ar (3000 SI), the flow is 49 LM (13 GM). D1VW*****L Shift Limits Important Notes for Switching Limit Charts 1. For F & M style valves, reduce flow to 70% of that shown. 2. Shift limits charted for equal flow and ports. Unequal and port flows may reduce shift limits. 3. hese charts do not show explosion proof performance. Consult factory for explosion proof duty. 4. locking or ports will reduce flow by 70%. D1.indd, dd 9 Elyria, Ohio, US

12 erformance Curves Series D1V D1V Shift Limits, DC & C Rectified 30 Watt Example: Determine the maximum allowable flow of a Series D1V valve (#008 spool) at 83 ar (1200 SI) supply pressure. Locate the curve marked 008. t 83 ar (1200 SI) supply pressure, the maximum flow is 57 LM (15 GM). t 207 ar (3000 SI), the flow is 19 LM (5 GM). D1VW*****L Shift Limits Important Notes for Switching Limit Charts 1. For F & M style valves, reduce flow to 70% of that shown. 2. Shift limits charted for equal flow and ports. Unequal and port flows may reduce shift limits. 3. hese charts do not show explosion proof performance. Consult factory for explosion proof duty. 4. locking or ports will reduce flow by 70%. D1.indd, dd 10 Elyria, Ohio, US

13 erformance Curves Series D1V D1V Shift Limits, DC & C Rectified 30 Watt Example: Determine the maximum allowable flow of a Series D1V valve (#081 spool) at 83 ar (1200 SI) supply pressure. Locate the curve marked 081. t 83 ar (1200 SI) supply pressure, the maximum flow is 42 LM (11 GM). t 138 ar (2000 SI), the flow is 42 LM (11 GM). D1VW*****L Shift Limits Important Notes for Switching Limit Charts 1. For F & M style valves, reduce flow to 70% of that shown. 2. Shift limits charted for equal flow and ports. Unequal and port flows may reduce shift limits. 3. hese charts do not show explosion proof performance. Consult factory for explosion proof duty. 4. locking or ports will reduce flow by 70%. D1.indd, dd 11 Elyria, Ohio, US

14 erformance Curves Series D1V D1V Shift Limits, C 30 Watt Supply ressure SI ar , , , ,004, 011, , , ,016, L/M 0 GM Flow D1.indd, dd 12 Elyria, Ohio, US

15 erformance Curves Series D1V D1VW*****F Shift Limits, C Example: Determine the maximum allowable flow of a Series D1V valve (#009 spool) at 83 ar (1200 SI) supply pressure. Locate the curve marked 009. t 83 ar (1200 SI) supply pressure, the maximum flow is 75 LM (20 GM). t 207 ar (3000 SI), the flow is 68 LM (18 GM). Soft Shift Limit Curves DC ower Supply Important Notes for Switching Limit Charts 1. For F & M style valves, reduce flow to 70% of that shown. 2. Shift limits charted for equal flow and ports. Unequal and port flows may reduce shift limits. 3. hese charts do not show explosion proof performance. Consult factory for explosion proof duty. 4. locking or ports will reduce flow by 70%. D1.indd, dd 13 Elyria, Ohio, US

16 Catalog HY /US echnical Information ressure Drop vs. Flow, High Watt he table to the right provides the flow vs. pressure drop curve reference for standard and high performance D1V Series valves by spool type. he chart below demonstrates graphically the pressure drop characteristics of the standard D1VW*****F and the high performance D1V. he low watt coil and other design features of the standard D1VW*****F accommodate a maximum flow of 50 LM (13 GM) at 345 ar (5000 SI). Series D1V D1VW ressure Drop Reference Chart 30 Watt Coil Curve Number Spool Shifted Center Condition No. ( ) ( ) ( ) (-) (-) (-) (-) Viscosity Correction Factor Viscosity (SSU) % of (pprox.) Curves were generated using 100 SSU hydraulic oil. For any other viscosity, pressure drop will change per chart. ressure drops charted for equal flow and ports. Unequal and port flows may decrease shift limits. erformance Curves 30 Watt Coil D1.indd, dd 14 Elyria, Ohio, US

17 echnical Information Series D1V ressure Drop vs. Flow, Low Watt he table to the right provides the flow vs. pressure drop curve reference for 10 watt D1V Series valves by spool type. he chart below demonstrates graphically the pressure drop characteristics of the standard D1VW*****L and the high performance D1V. he low watt coil and other design features of the standard D1VW*****L accommodate a maximum flow of 50 LM (13 GM) at 345 ar (5000 SI). D1VW ressure Drop Reference Chart 10 Watt Coil Curve Number Spool Shifted Center Condition No. ( ) ( ) ( ) (-) (-) (-) (-) Viscosity Correction Factor Viscosity (SSU) % of (pprox.) Curves were generated using 100 SSU hydraulic oil. For any other viscosity, pressure drop will change per chart. erformance Curves 10 Watt Coil D1.indd, dd 15 Elyria, Ohio, US

18 Notes D1.indd, dd 16 Elyria, Ohio, US

19 echnical Information Series D1VW General Description Series D1VW directional control valves are high performance, 4-chamber, direct operated, wet armature solenoid controlled, 3 or 4-way valves. hey are available in 2 or 3-position and conform to NF s D03, CEO 3 mounting patterns. Features Soft shift available. 19 standard spool styles available (for other spools Consult Factory). roportional spools. DC surge suppression. Eight electrical connection options. C & DC lights available (CS approval for solenoids and lights). Internally ground. Easy access mounting bolts. Waterproof (meets NEM 4, up to I67 on some models). Explosion proof. CS approvals. Specifications Mounting attern NF D03, CEO 3, NG 6 Mounting DIN Interface ISO CEO R35H , NF D03 Maximum,, ressure 345 ar (5000 SI) Standard 207 ar (3000 SI) 10 Watt CS 276 ar (3750 SI) ank: 103 ar (1500 SI) C only 207 ar (3000 SI) DC/C Rectified Standard 207 ar (3000 SI) C Optional CS 103 ar (1500 SI) U.L. recognized available - Contact the division. No tools required for coil removal. C rectified coils. Leakage Rates* Maximum llowable: cc (1.2 Cu. in.) per 49 C (120 F) 69 ar (1000 SI)* 73.8 cc (4.5 Cu. in.) per 207 ar (3000 SI)* *#008 and #009 ypical: Spools may 4.9 cc (0.3 Cu. in.) per exceed these rates. 69 ar (1000 SI)* Consult Factory 26.2 cc (1.6 Cu. in.) per 345 ar (5000 SI) Response ime Response time (milliseconds) at 345 ar (5000 SI) is 32 LM (8.5 GM). Solenoid ype ull-in Drop-Out C DC 10 Watt DC 30 Watt Spool Center Condition Orifice Closed Open 2-osition Soft Shift Size Energize De-Energize Energize De-Energize Energize De-Energize S ms 920 ms 200 ms 275 ms 51 ms 100 ms S ms 675 ms 50 ms 27 ms 51 ms 21 ms D1.indd, dd 17 Elyria, Ohio, US

20 Ordering Information Series D1V D Directional Control Valve 1V asic Valve ctuator Spool Style Seal Solenoid Voltage NF D03 CEO 3 DIN NG6 W* Solenoid, Wet in, Screw-in HW* Reversed Wiring * Valve schematic symbols are per NF/ NSI standards, providing flow to when energizing solenoid. Note operators reverse sides for #008 and #009 spools. See installation information for details. o configure per DIN standards ( coil over port, coil over port) code valves as D1VHW***. N Nitrile V Fluorocarbon E* ER * Contact HVD for availability. ** 24/50 VC Q** 100/60 VC D 120 VDC QD 100/60-100/50 VC G 198 VDC R 24/60 VC J 24 VDC 240/60-220/50 VC K 12 VDC U 98 VDC L 6 VDC Y 120/60-110/50 VC N*** 220/50 VC *** 110/50 VC ** High Watt only Z 250 VDC *** Explosion roof only. vailable in DIN only. Code Symbol Code Symbol Symbol * Single solenoid, 2 position, spring offset. b to and to in offset position * * ** 008*, ** * 008, 020 & 026 spools have closed crossover. ** 009 & 030 spools have open crossover. C D E F Double solenoid, 3 position, spring centered. Double solenoid, 2 position, detent. Single solenoid, 2 position, spring centered. to and to when energized. Single solenoid, 2 position. Spring offset, energized to center. osition spool spacer on side. to and to in spring offset position. H* Single solenoid, 2 position, spring offset. to and to in offset position. K Single solenoid, 2 position, spring centered. to and to when energized. M Single solenoid, 2 position, spring offset, energized to center position. Spool spacer on side. to and to in spring offset position. * 020, 026 and 030 spools only. 020 and 030 spools only. High Watt only. b b b b a a a a a D1.indd, dd old: Designates ier I products and options. Non-old: Designates ier II products and options. hese products will have longer lead times. 18 Elyria, Ohio, US

21 Ordering Information Series D1V D1.indd, dd Solenoid Connection C* Leadwire Conduit ox D** Metric lug (M12X1), DESIN E Explosion roof G lug-in Conduit ox J# Deutsch (D06-2S) M# Metri-ack (150) DIN with lug S# Dual Spade W DIN w/o lug * No variations See lug-in. ** DC only, lights, diode surge suppressor, not CS approved. Not available with lights. Required for variations on conduit box style. Must have lights. # DC only, no lights, not CS approved. Coil Options ube Options Manual Override Options Electrical Options Shift Response and Indication Omit Standard Response S2* Soft Shift, 0.020" Orifice S3* Soft Shift, 0.030" Orifice S4* Soft Shift, 0.040" Orifice S5* Soft Shift, 0.050" Orifice I7** Monitor Switch Direct Op. End Stroke I8** Monitor Switch Direct Op. Start Stroke * Not available with 10 watt. C DIN coil must include plug. ** Single solenoid models only. Not CE or CS approved. pprovals Valve Design Variations Series NOE: Not required when ordering. Omit* High Watt Omit No Options Omit Standard Valve D** Explosion roof, EEXD EX J** Diode Surge Suppressor 3* 4*# CS US CS Canada E** Explosion roof, Z Rectified Coil * Not available with C EEXME EX DC tube standard. high pressure tube. F Low Watt ** DC only. DIN coil must, C, H styles only. L 10 Watt have plug with lights. J, K, Y, U voltages only. C, G, W sol. connections O** Explosion roof, only. Conforms to UL429. MSH # Valve is derated. # Explosion roof, Ex d IIC EX/CS U ** Explosion roof, UL/CS Omit * Standard No Override Omit 5** No Variations Signal Lights * C ambient temperature must * Extended Manual Override 56* Manaplug (Mini) with Lights not exceed 60 C (140 F). w/oot ** 60 Hz only on C, no options. 7* Manaplug (Micro) with Lights C only. * Manual override options not available 1C* Manaplug (Mini) Single Sol. 5-pin, DC and C rectified only. on explosion proof or soft shift. with Lights # J, K and Y voltages only. Dual DC/C rectified only. 1D* Manplug (Micro) Single Sol. 5-pin, frequency on C, no options. with Lights 1M* Manaplug Opposite of Normal 4D wist & Lock Override Omit Standard ressure (Old 5426, 33 Ford wiring) ar (1500 SI) C Valve Weight: 4E ush Manual Override (Old x5450) 207 ar (3000 SI) DC Single Solenoid 1.36 kg (3.0 lbs.) 4F Heavy Duty Detent H* High ressure, C only Double Solenoid 1.6 kg (3.5 lbs.) 207 ar (3000 SI) 1 ainted ody Standard olt Kit: K209 * Not available with CS. 7Y* 4-pin M12x1 Manaplug, Metric olt Kit: KM209 special wiring with lights (Old 755) Seal Kit: Nitrile SKD1VWN91 * lug-in Conduit ox ** lug-in, DIN, or DESIN only Fluorocarbon SKD1VWV91 DC/C Rectified only. Not available with soft shift. old: Designates ier I products and options. Non-old: Designates ier II products and options. hese products will have longer lead times. 19 Elyria, Ohio, US

22 Dimensions Series D1V Inch equivalents for millimeter dimensions are shown in (**) DC lug-in Conduit ox Connector, with Lights, Double Solenoid Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. DC lug-in or Leadwire Conduit ox Connector, with or without Lights, Single Solenoid D1.indd, dd Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. 20 Elyria, Ohio, US

23 Dimensions Series D1V Inch equivalents for millimeter dimensions are shown in (**) DC DIN with lug Connector, Double Solenoid Option Shown DC DIN Connector, Single Solenoid Option Shown Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. D1.indd, dd Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. 21 Elyria, Ohio, US

24 Dimensions Series D1V Inch equivalents for millimeter dimensions are shown in (**) C Leadwire Conduit ox Connector, without Lights, Double Solenoid, C Option Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. C Leadwire Conduit ox Connector, without Lights, Single Solenoid, C Option D1.indd, dd Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. 22 Elyria, Ohio, US

25 Dimensions Series D1V Inch equivalents for millimeter dimensions are shown in (**) C lug-in Conduit ox Connector, with Lights, Double Solenoid, G Option Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. DC lug-in or Leadwire Conduit ox Connector, with or without Lights and Extended Override ubes, Double Solenoid D1.indd, dd Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. 23 Elyria, Ohio, US

26 Dimensions Series D1V Inch equivalents for millimeter dimensions are shown in (**) DC Deutsch Connector, Double Solenoid Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. DC Deutsch Connector, Single Solenoid D1.indd, dd Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. 24 Elyria, Ohio, US

27 Dimensions Series D1V Inch equivalents for millimeter dimensions are shown in (**) DC Desina Connector, Double Solenoid 87.8 (3.46) DC Desina Connector, Single Solenoid Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. D1.indd, dd Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. 25 Elyria, Ohio, US

28 Dimensions Series D1V Inch equivalents for millimeter dimensions are shown in (**) Explosion roof, Ex d IIC EX/CS, Double Solenoid Explosion roof, Ex d IIC EX/CS, Single Solenoid D1.indd, dd 26 Elyria, Ohio, US

29 Dimensions Series D1V Inch equivalents for millimeter dimensions are shown in (**) Explosion roof U.L. & C.S.., Double Solenoid 1/2" N 60.4 (2.38) (6.44) hase Out (5.15) (11.98) Note: 41.0 mm (1.62") from bottom of bolt hole counterbore to bottom of valve. 18 Inch Lead Wires Standard 94.4 (3.72) 46.0 (1.81) 73.0 (2.87) Note: 2 black wires 1 green wire 15.1 (0.61) 7.5 (0.30) Explosion roof M.S.H.., Double Solenoid 3/4-20 UNF hd (2.38) (6.44) 3/4-20 UNF hd (1.50) (4.45) (5.15) (6.44) Note: 41.0 mm (1.62") from bottom of bolt hole counterbore to bottom of valve. Explosion roof, EEXD EX, Double Solenoid 46.0 (1.81) 73.0 (2.87) (0.61) 7.5 (0.30) 74.7 (2.94) 69.9 (2.75) 19.4 (0.76) 15.5 (0.61) M20 x 1.5-6H hd. Ground Stud with Lockwasher (3.97) 42.8 (1.69) (5.19) (3.96) D1.indd, dd 7.5 (0.30) 46.0 (1.81) 73.5 (2.89) (5.55) (12.78) 27 Elyria, Ohio, US

30 Dimensions Series D1V Inch equivalents for millimeter dimensions are shown in (**) DC lug-in or Leadwire Conduit ox with Monitor Switch, with or without Lights, Single Solenoid Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. Monitor Switch (Variation I7 and I8) his feature provides for electrical confirmation of the spool shift. his can be used in safety circuits, to assure proper sequencing, etc. Switch Data Inductive switch requiring volt input. Outputs and are opposite; one at 0 voltage, the other at input voltage. During switching, and outputs reverse. rovides 0.4 switching current. For repetitive switch power-up conditions, please consult factory. D1.indd, dd 28 Elyria, Ohio, US

31 ccessories Manaplug (Options 56 & 1C) Interface rad Harrison lug 3-in for Single Solenoid 5-in for Double Solenoid Ground Wire #1 (Green) Series D1V Micro Connector Options (7 & 1D) Solenoid (Negative) Wire #3 (Red/lack) Solenoid (ositive) Wire #2 (Red/White) 3-in Manaplug (Mini) with Lights Single Solenoid Valves Installed Opposite Side of Solenoid ins are as seen on valve (male pin connectors) Conduit ox Option C No Wiring Options vailable Signal Lights (Option 5) lug-in Only LED Interface Meets Nema 4/I67 Hirschmann lug with Lights (Option 5) DESIN Connector (Option D) ISO 4400/DIN Form D1.indd, dd in #2 (ositive) Face View of lug in #3 (Ground) in #1 (Negative) M12 pin assignment Standard 1 = Not used 2 = Not used 3 = 0V 4 = Signal (24 V) 5 = Earth Ground ins are as seen on valve (male pin connectors) DESIN design in 1 and 2 connected Elyria, Ohio, US

32 ccessories Series D1V Mounting olt Kits olt Kits for use with D1V, "E" Explosion roof & Sandwich Valves (D1V*-91, 82 & 70/75 Design, Solenoid Operated & D1V*-72 Design, Non-Solenoid Operated) Number of Sandwich Valves at 44.5mm (1.75") hickness Note: Number of Sandwich (1.58") thickness K in. K in. K in. K in. K in. KM mm KM mm KM mm KM mm KM mm K in. K in. K in. K in. KM mm KM mm KM mm KM mm K in. K in. K in. KM mm KM mm KM mm K in. K in. KM mm KM mm K in. KM mm ll bolts are SE Grade 8, UNC 2 thread (Metric-M5-0.8) orque to 5.6 Nm (50 in-lb). olt Kits for use with D1V with Explosion roof Coils & Sandwich Valves (D1V*-91, 82 & 70/75 Design) Except "E" Coil Number of Sandwich Valves at 44.5mm (1.75") hickness Note: Number of Sandwich (1.58") thickness K in. K in. K in. K in. K in. KM50 50 mm KM mm KM mm KM mm K in. K in. K in. K in. KM51 95 mm KM mm KM mm K in. K in. K in. KM mm KM mm K in. K in. KM mm K in. KM mm ll bolts are SE Grade 8, UNC 2 thread (Metric-M5-0.8) orque to 5.6 Nm (50 in-lb). Sandwich Valve Dimensional Data ll D03 Sandwich valves (starting with 31 Series) including CM2, COM2, FM2, RDM2 and RM2 measure 40mm (1.58") thickness. For additional technical information about Sandwich valves, refer to the Sandwich Valve Section of this Catalog. D1.indd, dd 30 Elyria, Ohio, US

33 echnical Information Series D1V, D1V General Description Series D1V and D1V directional control valves are high performance, 4 and 5-chamber, direct operated, air and oil pilot controlled, 3 or 4-way valves. hey are available in 2 or 3-position and conform to NF s D03, CEO 3 mounting patterns. Features Low pilot pressure required. D1V 4.1 ar (60 SI) minimum D1V 15.2 ar (220 SI) minimum ir Operated Shift Volume. he air pilot chamber requires a volume of 1.8 cc (.106 in. 3 ) for complete shift from center to end. ilot iston. he pilot piston area is 506 mm 2 (.785 in. 2 ). ilot piston stroke is 3.4 mm (.135 in.). Response ime. Response time will vary with pilot line size, pilot line length, pilot pressure, air control valve shift time and air valve flow capacity (Cv). Oil Operated Shift Volume. he hydraulic pilot chamber requires a volume of 0.7 cc (.042 in. 3 ) for complete shift from center to end. ilot iston. he hydraulic piston area is 198 mm 2 (.307 in. 2 ). ilot piston stroke is 3.4 mm (.135 in.). Response ime. Response time will vary with pilot line size, pilot line length, pilot pressure, pilot valve shift time and oil valve flow capacity (GM). Specifications Mounting attern NF D03, CEO 3, NG 6 Maximum Operating: 345 ar (5000 SI) ressure ank Line: D1V 34 ar (500 SI) D1V 207 ar (3000 SI) Maximum Flow See Reference Data D1V: ir Minimum 4.1 ar (60 SI) ilot ressure ir Maximum 10.2 ar (150 SI) D1V: Oil Minimum 15.2 ar (220 SI) Oil Maximum 207 ar (3000 SI) Dimensions Inch equivalents for millimeter dimensions are shown in (**) Oil Operated D1V, Single and Double ilot 51.0 (2.00) min (1.60) 42.0 (1.65) 16.9 (0.67) Y 1/4 S (90) or SE # (0.61) 23.0 (0.91) 43.0 (1.70) min (0.87) 9.0 (0.35) See Note 50.0 (1.97) 3.3 (0.13) max. X &Y orts 0.56 (0.022) (5.13) 46.0 (1.81) 23.8 (0.94) D1.indd, dd Note: 22.0 mm (0.87 ) from bottom of bolt hole counterbore to bottom of valve. 31 Elyria, Ohio, US

34 Ordering Information Series D1V D Directional Control Valve 1V asic Valve ctuator Spool Style Seal Variations Design Series NOE: Not required when ordering. NF D03 CEO 3 Oil Operator Omit Standard 10* Monitor Switch 4F Heavy Duty Detent 90 Shreads * Not available on C and D styles. Not CE or CS approved. Code 001 Symbol Code N V Description Nitrile Fluorocarbon Valve schematic symbols are per NF/NSI standards, providing flow to when energizing operator X. Note operators reverse sides for #008 and #009 spools. See installation information for details. D1.indd, dd * 009** 020* 026* 030** Symbol Single operator, two position # spring offset. to and to in offset position. Double operator, C three position, spring centered. D Double operator, two position, detent. wo position, spring centered. E# to and to in shifted position. Single operator, two position, H# spring offset. to and to in offset position. wo position, spring centered. K# to and to in shifted position. # D available with 020 and 030 spools only. & H available with 020, 026 and 030 spools only. E & K not available with 020, 026 and 030 spools. his condition varies with spool code. * 008, 020 and 026 spools have closed crossover. Valve Weight: 1.90 kg (4.2 lbs.) ** 009 and 030 spools have Standard olt Kit: K x1.25 open crossover. Metric olt Kit: KM209 M5 0.8x30mm Seal Kit: Nitrile SKD1V Fluorocarbon SKD1VV old: Designates ier I products and options. Non-old: Designates ier II products and options. hese products will have longer lead times. 32 Elyria, Ohio, US

35 Ordering Information Series D1V D Directional Control Valve 1V asic Valve ctuator Spool Style Seal Variations Design Series NOE: Not required when ordering. NF D03 CEO 3 ir Operator Omit Standard 10* Monitor Switch 90 1/4 Shreads * Not available on C & D styles. Not CE or CS approved. Code * 009** Symbol * 008 spool has closed crossover. ** 009 spool has open crossover. Valve schematic symbols are per NF/ NSI standards, providing flow to when energizing operator. Note operators reverse sides for #008 and #009 spools. See installation information for details. Code N V Description Nitrile Fluorocarbon Symbol Single operator, two position b spring offset. to and to in offset position. Double operator, b C three position, spring centered. D E H K Double operator, two position, detent. wo position, spring centered. to and to in shifted position. Single operator, two position, spring offset. to and to in offset position. wo position, spring centered. to and to in shifted position. his condition varies with spool code. b b a a a a D1.indd, dd old: Designates ier I products and options. Valve Weight: 1.60 kg (3.5 lbs.) Standard olt Kit: K x1.25 Metric olt Kit: KM209 M5 0.8x30mm Grade 8 bolts required Seal Kit: Nitrile SKD1V Fluorocarbon SKD1VV Non-old: Designates ier II products and options. hese products will have longer lead times. 33 Elyria, Ohio, US

36 Dimensions Series D1V Inch equivalents for millimeter dimensions are shown in (**) ir Operated D1V, Double ilot 61.6 (2.43) (4.64) (4.12) 1/8 N yp. or S (7.58) 38.5 (1.52) (2.05) 23.8 (0.94) Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve (0.91) 46.0 (1.81) ir Operated D1V, Single ilot Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. D1.indd, dd 34 Elyria, Ohio, US

37 echnical Information Series D1VC, D1VD, D1VG General Description Series D1VC, D1VD and D1VG directional control valves are high performance, 4-chamber, direct operated, cam controlled, 4-way valves. hey are available in 2-position and conform to NF s D03, CEO 3 mounting patterns. Features Choice of 2 cam roller positions (D1VC and D1VD) wo styles available (D1VC and D1VG) Short stroke option Specifications Mounting attern NF D03, CEO 3, NG 6 Maximum Operating: 345 ar (5000 SI) ressure ank Line: 34 ar (500 SI) Nominal Flow 32 LM (8.5 GM) Maximum Flow See Reference Data Force Required D1VC, D1VD: 107 N (24 lbs.) to Shift D1VG: 36 N (8 lbs.) Maximum Cam ngle 30 Ordering Information D Directional Control Valve Valve Weight: D1.indd, dd 1V asic Valve NF D03 CEO 3 Code C D G Description Cam (90 to mounting surface) Cam parallel to mounting surface Cam Lever ype C & D 1.44 kg (3.2 lbs.) ype G 1.6 kg (3.7 lbs.) Standard olt Kit: K x1.25 Metric olt Kit: KM209 M5 0.8x30mm Seal Kit: Nitrile SKD1VC Fluorocarbon SKD1VCV ctuator Spool Style Seal Variations Design Code * Symbol Code N V Description Nitrile Fluorocarbon Omit Standard 05 Short Stroke 10* Monitor Switch * Not CE or CS approved. Symbol wo position, spring offset operator at port end. wo position, H spring offset operator at port end. Valve schematic symbols are per NF/ NSI standards, providing flow to when 082 energized. Note flow paths reverse sides for #008 and #009 spools. * 008 spool has closed crossover. 009 spool has open crossover. old: Designates ier I products and options. Series NOE: Not required when ordering. Non-old: Designates ier II products and options. hese products will have longer lead times. 35 Elyria, Ohio, US

38 Dimensions Series D1VC, D1VD, D1VG Inch equivalents for millimeter dimensions are shown in (**) Cam Operated D1VC and D1VD Full Valve ype re-ravel Spool Over-ravel ravel Standard Valve (0.079) (0.357) (0.080) Short Stroke (0) (0.278) (0.159) 38.5 (1.52) Over-ravel Full Spool ravel re-ravel 38.4 (1.51) 52.0 (2.05) 23.8 (0.94) Note: For D1VD, Cam Rotated (6.53) Cam Lever Operated D1VG 23.0 (0.91) Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve (1.81) Full Valve ype re-ravel Spool Over-ravel ravel Standard Valve (0.27) (1.56) (0.39) Short Stroke (0) (1.19) (0.72) Over-ravel Full Spool ravel re-ravel 38.5 (1.52) 38.5 (1.52) See Note 79.1 (3.11) 52.0 (2.05) 23.8 (0.94) D1.indd, dd (0.91) (8.26) 46.0 (1.81) Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. 36 Elyria, Ohio, US

39 echnical Information Series D1VL General Description Series D1VL directional control valves are highperformance, 4-chamber, direct operated, lever controlled, 4-way valves. hey are available in 2 or 3-position and conform to NF s D03, CEO 3 mounting patterns. Features Spring return or detent styles available Heavy duty handle design Specifications Mounting attern NF D03, CEO 3, NG 6 Maximum Operating: 345 ar (5000 SI) ressure ank Line: 34 ar (500 SI) Maximum Flow See Reference Data Force Required to Shift Lever 25 N (5.6 lbs) Operator Dimensions Inch equivalents for millimeter dimensions are shown in (**) Lever Operated D1VL 85.5 (3.37) 8.9 Full Shift 15.5 (0.61) 15.5 (0.61) 38.6 (1.52) (5.93) See Note 46.0 (1.81) 50.0 (1.97) 23.8 (0.94) Note: 22.0 mm (0.87") from bottom of bolt hole counterbore to bottom of valve. D1.indd, dd (5.89) (0.91) 46.0 (1.81) Elyria, Ohio, US

40 Ordering Information Series D1VL D Directional Control Valve 1V asic Valve Operator ype and Location Spool Style Seal Variations Design Series NOE: Not required when ordering. NF D03 CEO 3 Operator Location ( or ort End) Code Operator ype For Valve Style C D E H K N L Lever (Standard) L Lever (lternate) N/ N/ Code N V Omit Standard 10* Monitor Switch * Not available on C,D or N styles. Not CE or CS approved. Description Nitrile Fluorocarbon Code * * 082 Symbol * 008 and 081 spools have closed crossover. 009 has open crossover. Symbol wo position, spring offset. to and to in offset position. C D E H K N hree position, spring centered. wo position, detent. wo position, spring centered. to and to in shifted position. wo position, spring offset. to and to in offset position. wo position, spring centered. to and to in shifted position. hree position, detent. his condition varies with spool code. Valve schematic symbols are per NF/ NSI standards, providing flow to when energizing operator. Note flow paths reverse sides for #008 and #009 spools in three position valves. Valve Weight: 1.60 kg (3.5 lbs.) Standard olt Kit: K x1.25 Metric olt Kit: KM209 M5 0.8x30mm Grade 8 bolts required Seal Kit: Nitrile SKD1VL Fluorocarbon SKD1VLV D1.indd, dd old: Designates ier I products and options. Non-old: Designates ier II products and options. hese products will have longer lead times. 38 Elyria, Ohio, US

41 Installation Information Series D1V Fluid Recommendations remium quality hydraulic oil with a viscosity range between cst. ( SSU) at 38 C (100 F) is recommended. he absolute operation viscosity range is from cst. ( SSU). Oil should have maximum anti-wear properties and rust and oxidation treatments. Fluids and Seals Valves using synthetic, fire-resistant fluids require special seals. When phosphate ester or its blends are used, fluorocarbon seals are required. Waterglycol, (95/5) water-in-oil emulsions, and petroleum oil may be used with NIRILE seals. emperature Recommendation Recommended oil temperature: -29 C to +71 C (-20 F to +160 F) mbient temperature: C High Watt ambient temperature cannot exceed 60 C (140 F). DC High Watt, DC Low Watt and C Low Watt ambient temperature cannot exceed 71 C (160 F). Filtration For maximum valve and system component life, the system should be protected at a contamination level not to exceed 125 particles greater than 10 microns per milliliter of fluid. (SE Class 4 or better, ISO Code 16/13). ank Line Surges If several valves are piped with a common tank line, flow surges in the line may cause unexpected spool shift. Detent style valves are most susceptible to this. Separate tank lines should be used when line surges are expected in an application. Recommended Mounting osition Valve ype Detent (Solenoid) Spring Centered Spring Offset Recommended Mounting osition Horizontal Unrestricted Unrestricted Silting Silting can cause any sliding spool valve to stick and not spring return, if held shifted under pressure for long periods of time. he valve should be cycled periodically to prevent sticking. Flow ath Data D1V Operator Operator *Note: On valves with 008 or 009 spool, and/or operators reverse sides. Flow paths remain the same as viewed from top of valve. Single ass Operation Valve flow ratings are for double pass operation (with equal flow in both paths). When using these components in single pass applications, flow capabilities may be reduced. Consult your local arker representative for details. Double Solenoid. With solenoid energized, flow path is and. When solenoid is energized, flow path is and. he center condition on a spring-centered valve exists when both coils are de-energized, or during a complete shift, as the spool passes through center. Detent and Spring Offset. he center condition exists on detent and spring offset valves only during spool crossover. o shift and hold a detented spool, only a momentary energizing of the solenoid is necessary. he minimum duration of the signal is approximately 0.1 seconds for DC voltages. his position will be held provided the spool center line is in a horizontal plane, and no shock or vibration is present to displace the spool. Single Solenoid. Spring offset valves can be ordered in styles, E, F, H, K and M. Flow path data for the various styles are described in the order chart. Electrical Failure Should electric power fail, spring offset and spring centered valves will shift to the spring held position. Detented valves will stay in the last position held before power failure. If main flow does not fail or stop simultaneously, machine actuators may continue to function in an undesirable manner or sequence. orque Specifications orque values recommended for the bolts which mount the valve to the manifold or subplate are as follows: #10-24 thread (M5-0.8) torque 5.6 Nm (50 in-lbs). D1.indd, dd 39 Elyria, Ohio, US

42 Installation Information Series D1V Mounting attern NF D03, CEO 3, NG 6 Inch equivalents for millimeter dimensions are shown in (**) (2.000) min (1.594) (1.300) M5-0.8 (10-24) UNC-2 thread x (.410) min. thread depth 4-holes 0.28 S (0.011) 5.10 (0.200) 0.75 (0.030) (0.850) (1.190) (1.70) min (1.250) (1.220) (1.020) (0.610) O 7.5 (.295) max.... & ports 0.56 L (0.022) O 3.86/4.27 (.152/.168) x 4.00 (.160) min. depth 0.28 S (0.011) (0.500) 4.80 (0.190) R. max. typ. 4 places D1.indd, dd 40 Elyria, Ohio, US

43 echnical Information Series D1SE General Description Series D1SE directional control valves are equipped with a wet pin armature solenoid, drain-free, tapered poppet valve and compatible with the standards DIN NG6, CEO 3, and NF D03. Due to the 3/2 way design, port is either connected with or discharged in the tank. he neutral position (solenoid not activated) is taken automatically by a return spring. his position remains until the solenoid is energized. he valve poppet including activation lever and armature of the solenoid are located in the pressurized oil chamber of connection. he valve poppet is designed such that there can be no differential area in its axial operational direction (opening, closing). hus it is statically pressure-balanced so that the valve can be switched in both flow directions even under pressure. he unit has an all-steel design, the important functional inner parts are hardened, the poppet and seat are ground. Features Low leakage poppet design. Fits NF D03 mountng. ressure balanced. Ordering Information D 1 S E W Directional Control Valve asic Valve Seat Valve Wet in rmature Solenoid, Flanged DIN NG6 CEO 3 N D03 Code Spool Description Style Seal Solenoid Voltage Solenoid Connection Without lug K 12V J 24V U* 98V G* 205V Design Series NOE: Not required when ordering. * For alternating current use plug with rectifier. Coils for repair Voltage Ordering Code 12V V 24V V 98V V 205V V Code N V Description Nitrile Fluorocarbon Weight: 0.8 kg (1.76 lbs) old: Designates ier I products and options. Non-old: Designates ier II products and options. hese products will have longer lead times. D1.indd, dd 41 Elyria, Ohio, US

44 Specifications Series D1SE General Design Directional poppet valve ctuation Solenoid Size DIN NG6 / CEO 3 / NF D03 Mounting Interface DIN / ISO 4401 / CEO R 121-H / NF D03 Mounting osition Unrestricted mbient -25 C to +50 C (-13 F to +122 F), emperature observe permissible duty cycle Hydraulic Max. Operating 350 ar (5075 SI) (,, and ) ressure Fluid Hydraulic oil in accordance with DIN / Fluid emperature -25 C to +70 C (-13 F to +158 F) Viscosity ermitted cst / mm²/s ( SSU) Recommended cst / mm²/s ( SSU) Filtration ISO 4406 (1999); 18/16/13 (meet NS 1638: 7) Internal Leakage 3-5 DM per seat Maximum Flow 20 LM (5.28 GM) (at p = 10 bar) Static / Dynamic Step Response Energized: approx. 50 ms De-energized: approx. 60 ms Electrical Characteristics Duty Ratio See Diagram Max. Switching /h Frequency rotection Class I 65 in accordance with DIN (plugged and mounted) Code K J U* G* Supply Voltage 12 VDC 24 VDC 98 VDC 205 VDC olerance Supply ±10% ±10% ±10% ±10% Voltage Current Consumption ower Consumption 23.4 W 26.4 W 24.3 W 26.6 W Solenoid Connector as per EN Connection Min. Wiring 3 x 1.5 mm 2 recommended Max. Wiring Length 50m (164') recommended * For a silicon bridge rectifier, set up apart from unit for connecting to a 50 or 60 Hz power supply, 110 V~(98=) or 230V~ (205V=). With electrical connections the protective conductor (E ) must be connected according to the relevant regulations. D1.indd, dd 42 Elyria, Ohio, US

45 echnical Information Series D1SE erformance Curves SI 290 ar 20 erformance Curve p-q F 176 C 80 Duty Cycle vs. mbient emperature ressure Drop mbient emperature LM 0 GM Flow Q Rel. ED % " 5 min. Dimensions Inch equivalents for millimeter dimensions are shown in (**) 58.0 (2.28) Ø 9.0 (0.35) M (0.87) 45.0 (1.77) 62.0 (2.44) 14.0 (0.55) 5.0 (0.20) 35.0 (1.38) 45.0 (1.77) O-ring 9.25 x 1.8 NR 90 Sh Surface Finish Seal K375 4x M5x Nm ± 15% Nitrile: SK-D1SE-70 DIN Fluorocarbon: SK-D1SE-V70 he space necessary to remove the plug per EN , design type F is at least 15 mm. he torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm. D1.indd, dd 43 Elyria, Ohio, US

46 Catalog HY /US Introduction pplication Series D3 hydraulic directional control valves are high performance, direct operated 4-way valves, available in 2 or 3-position. hey are manifold mounted which conform to NF s D05, CEO 5, ISO NG10 mounting patterns. hese valves were designed for industrial and mobile hydraulic applications which require high cycle rates, long life and high efficiency. Operation Series D3 directional control valves consist of a 4-chamber style body, and a case hardened sliding spool. he spool is directly shifted by a variety of operators including: solenoid, lever, cam, or air pilot. Series D3 Features Easy access mounting bolts. 345 ar (5000 SI) pressure rating. Flows to 40 GM depending on spool. Choice of four operator styles. Rugged four land spools. Low pressure drop. hosphate finish body. CS approved and UL recognized available. roportional spool available. D3W Solenoid Operated Conduit Cavity Style Wired in cavity. Easy access mounting bolts. 22 spool styles available. hree electrical connection options. C and DC lights available. CS approved. vailable in low-watt DC version. D3W Solenoid Operated Hirschmann (DIN) Style DIN Style (43650) Hirschmann. 22 spool styles available. No tools required for coil removal. Easy coil replacement. C and DC lights available. CS approved. vailable in low-watt DC version. D3.indd, dd 44 Elyria, Ohio, US

47 Introduction Series D3 D3L Lever Operated Spring return or detent styles available. Heavy duty handle design. High flow, low pressure drop design. D3 ir Operated Low pilot pressure required 4.1 ar (60 SI) minimum. High flow, low pressure drop design. D3C Cam Operated Choice of 2 cam roller positions (D3C and D3D). Short stroke option. High flow, low pressure drop design. D3.indd, dd 45 Elyria, Ohio, US

48 Catalog HY /US Introduction pplication Series D3DW hydraulic directional control valves are high performance, direct operated 4-way valves, available in 2 or 3-position. hey are manifold mounted which conform to NF s D05, CEO 5, ISO NG10 mounting pattern. hese valves were designed for industrial and mobile hydraulic applications which require high cycle rates, long life and high efficiency. Series D3DW Operation Series D3DW directional control valves consist of a 5-chamber style body, and a case hardened sliding spool. D3DW Solenoid Operated Hirschmann (DIN) Style Easy access mounting bolts. No tools required for coil removal. 22 spool styles available. Signal lights available. CS approved. D3.indd, dd 46 Elyria, Ohio, US

49 echnical Information Series D3 D3 Spool Reference Data Model Spool Symbol D3W D3W*F D3DW D3*1 150 (40) 78 (20) 130 (33) D3*2 150 (40) 78 (20) 115 (30) D3*3 150 (40) 78 (20) 120 (31) D3*4 150 (40) 59 (15) 130 (33) D3*5 150 (40) 78 (20) 130 (33) D3*6 150 (40) 78 (20) 130 (33) D3*7 50 (13) 59 # (15) 70 (18) D3*8 50 (13) 59 # (15) 39 (10) D3*9 39 (10) 59 # (15) 75 (19) D3* (30) N/ 75 (19) D3* (30) 59 # (15) 130 (33) Maximum Flow, LM (GM) 350 ar (5000 SI) w/o Malfunction Model Spool Symbol D3W D3W*F D3DW D3*12 95 (24) 59 (15) 75 (19) D3*14 50 (13) 59 # (15) 70 (18) D3* (40) 78 (20) 120 (31) D3* (40) 78 (20) 130 (33) D3* (40) 78 (20) 130 (33) D3* (30) N/ 120 (31) D3* (30) N/ 120 (31) D3* (30) N/ 75 (19) D3*30 39 (10) 59 # (15) 75 (19) D3* (30) N/ 130 (33) D3* (30) N/ 130 (33) Maximum Flow, LM (GM) 350 ar (5000 SI) w/o Malfunction Center or De-energized position is indicated by,, & port notation SI Max SI Max. # 1500 SI Max. D3, D3C, D3L Spool Reference Data (Four Chamber ody Only) Model Spool Symbol Maximum Flow, LM (GM) 350 ar (5000 SI) w/o Malfunction Maximum Flow, LM (GM) 350 ar (5000 SI) Model Spool Symbol w/o Malfunction D3*1 150 (40) D3*2 150 (40) D3*4 150 (40) D3*8 50 (13) D3* (40) D3* (30) D3*30 39 (10) D3* (30) D3*9 39 (10) D3* (30) Center or De-energized position is indicated by,, & port notation. D3.indd, dd 47 Elyria, Ohio, US

50 erformance Curves Series D3 D3W-30/32 DC and C Rectified Shift Limits SI ar , 30 10, 21, 22, 26 Supply ressure , , 9, 30 11, 81, LM 0 GM D, 26D 30D Flow 1, 2, 3, 4, 5, 6, 15, 16, Example: Determine the maximum allowable flow of a D3W Series valve (20D) at 150 ar (2175 SI) supply pressure. Locate the curve marked 20D. t 150 ar (2175 SI) supply pressure, the maximum flow is 98 LM (25 GM). t 345 ar (5000 SI), the flow is 72 LM (18.5 GM). Important Notes for Switching Limit Charts 1. For F & M style valves, reduce flow to 70% of that shown. 2. Shift limits charted for equal flow and ports. Unequal and port flows may reduce shift limits. 3. hese charts do not show explosion proof performance. Consult factory for explosion proof duty. 4. locking and ports will reduce flow to 70% of that shown. D3W-30/32 Low Watt DC and C Rectified Shift Limits SI ar Supply ressure , 8, 9 11, 12, 14, , 2, 3, 5, 6, 15, 16, 20 0 LM 0 GM Flow D3.indd, dd 48 Elyria, Ohio, US

51 erformance Curves Series D3 D3W-30/32 C Shift Limits Supply ressure SI ar , 4, 5, 15, 16, 30 1, 3, 4, 5, 15, 16, 20, , 6, , 8, 14 20D, 30D 0 LM 0 GM Flow D3W-30/32 Soft Shift Limits (High Watt Coil Only) D3.indd, dd Important Notes for Switching Limit Charts 1. For F & M style valves, reduce flow to 70% of that shown. 2. Shift limits charted for equal flow and ports. Unequal and port flows may reduce shift limits. 3. hese charts do not show explosion proof performance. Consult factory for explosion proof duty. 4. locking and ports will reduce flow to 70% of that shown. 49 Elyria, Ohio, US

52 erformance Curves Series D3 D3W-30/32 Soft Shift Response Response ime* Signal to 95% spool stroke measured at 172 ar (2500 SI) and 65 LM (17 GM). Soft Shift Option Energize De-energize S S S * For reference only. Response time varies with flow, pressure and oil viscosity. D3DW-40/41 Shift Limits D3.indd, dd Important Notes for Switching Limit Charts 1. For F & M style valves, reduce flow to 70% of that shown. 2. Shift limits charted for equal flow and ports. Unequal and port flows may reduce shift limits. 3. hese charts do not show explosion proof performance. Consult factory for explosion proof duty. 4. locking and ports will reduce flow to 70% of that shown. 50 Elyria, Ohio, US

53 echnical Information Series D3 ressure Drop vs. Flow he table shown provides flow vs. pressure drop curve reference for D3 Series valves by spool type. he chart below demonstrates graphically the performance characteristics of the D3. he low watt coil and other design features of the standard D3W*****F accommodate a maximum flow of 78 LM (20 GM) at 207 ar (3000 SI). D3W and D3DW ressure Drop Reference Chart Curve Number Spool Shifted Center Condition No. ( ) ( ) ( ) (-) (-) (-) (-) erformance Curves Note: For 81 and 82 spools, consult factory. Viscosity Correction Factor Viscosity (SSU) % of (pprox.) Curves were generated using 110 SSU hydraulic oil. For any other viscosity, pressure drop will change per chart. D3.indd, dd 51 Elyria, Ohio, US

54 Notes D3.indd, dd 52 Elyria, Ohio, US

55 echnical Information Series D3W General Description Series D3W directional control valves are high-performance, 4-chamber, direct operated, wet armature, solenoid controlled, 3 or 4-way valves. hey are available in 2 or 3-position and conform to NF s D05, CEO 5 mounting patterns. Features Worldwide, high flow, low pressure drop design. Soft shift available. 22 spools available including proportional. DC surge suppression available to protect electrical equipment. hree electrical connection options. C & DC lights available. Easy access mounting bolts. Explosion proof availability. CS approved. No tools required for coil removal. Rectified coils available for high flow C applications. Response ime (ms) Signal to 95% spool stroke measured at 172 ar (2500 SI) and 75 LM (20 GM) Solenoid ype m sec C Energize 21 C De-energize 35 DC Energize 110 DC De-energize 85 Specifications Interface NF D05, CEO 5, NG 10 Max. Operating,, : ressure 345 ar (5000 SI) Standard CS 207 ar (3000 SI) ank: 103 ar (1500 SI) C Standard 207 ar (3000 SI) C Optional DC/C Rectified Standard CS 103 ar (1500 SI) CS File Number LR Leakage Rates Maximum llowable: cc (0.38 Cu. in.) per Minute/ 49 C (120 F) 69 ar (1000 SI)* 35 cc (2.19 Cu. in.) per Minute/ 207 ar (3000 SI)* * #008 and #009 Spools may exceed these rates, consult factory D3.indd, dd 53 Elyria, Ohio, US

56 Ordering Information Series D3W D 3 Directional Control Valve W asic Valve ctuator Spool Style Seal Solenoid Voltage NF D05 CEO 5 NG 10 Wet armature solenoid Code Symbol Code Symbol 1 14 Code N V Description Nitrile Fluorocarbon E# 24/60-24/50 VC Y 120/60-110/50 VC 240/60-220/50 VC K 12 VDC J 24 VDC D# 120 VDC U# 98 VDC Z# 250 VDC # High Watt Coil only * * 8* 30** 9** * 8, 20 & 26 spools have closed crossover. ** 9 & 30 spools have open crossover. vailable only with high-watt rectified C coils or high-watt DC coils. Spring centered versions C, E, F, K & M only. Symbol Single solenoid, 2 position, b * spring offset. to and to in offset position C Double solenoid, 3 position, spring centered. D Double solenoid, 2 position, detent Single solenoid, 2 position, E spring centered. to and to when energized. Single solenoid, 2 position. Spring offset, F** energized to center position. Spool spacer on side. to and to in spring offset position. Single solenoid, 2 position, H* spring offset. to and to in offset position. Single solenoid, 2 position. K Spring centered. to and to when energized. Single solenoid, 2 position, spring offset, energized M** to center position. Spool spacer on side. to and to in spring offset position. * Only spools 20, 26 & 30. ** High Watt Coil. Only spools 20 & 30. his condition varies with spool code. b b b b a a a a a Valve schematic symbols are per NF/NSI standards, providing flow to when energizing solenoid. Note operators reverse sides for #8 and #9 spools. See installation information for details. old: Designates ier I products and options. D3.indd, dd Non-old: Designates ier II products and options. hese products will have longer lead times. 54 Elyria, Ohio, US

57 Ordering Information Series D3W Solenoid Connection C** Conduit Cavity K Conduit ox J#* Deutsch (D06-2S) Hirschmann w/lug W* Hirschmann w/o lug E* Explosion roof * Lights not available. ** No variations (See K ). # DC voltage only. Solenoid/ube Options Manual Override Options Omit Standard ube * Extended Manual Override * Not available with soft shift or explosion proof. Electrical Options Shift Response and Indication pprovals Omit Standard Valve 3* CS US (UL429) 4* CS Canada * Not available with C high pressure tube., C, H styles only. Y voltage with conduit connection only, must be rectified. Variations Design Series NOE: Not required when ordering. Options Coil ube Rating C DC/C Rectified Omit High Watt ar (1500 SI) 207 ar (3000 SI) F*# Low Watt n/a 207 ar (3000 SI) H High Watt 207 ar (3000 SI) n/a D Explosion roof, EEXD EX U Explosion roof, UL/CS * vailable only with J, K and Y (Rectified), (Rectified) voltages. # Not available with soft shift or with F and M style valves. Explosion proof coils are 60 Hz at standard voltage; dual rating not available. Valve Weight: Single Solenoid: C 4.3 kg (9.5 lbs.) DC 5.3 kg (11.6 lbs.) Double Solenoid: C 5.0 kg (11.0 lbs.) DC 7.3 kg (16.0 lbs.) Seal Kit: Nitrile SKD3W Fluorocarbon SKD3WV Mounting olt Kits Omit No Option V# Varistor Surge Suppressor Z C Rectified with MOV Surge Suppressor # DC voltage only. UNC olt Kits for use with D3W & Sandwich Valves Number of Sandwich 2.00 (50mm) thickness D3W Standard: K98 K141 K142 K Metric: KM98 KM141 KM142 KM143 40mm 90mm 140mm 190mm D3W with Standard: K144 K61 K62 K63 explosion proof coils Metric: KM144 KM61 KM62 KM63 60mm 110mm 160mm 210mm NOE: ll bolts are SE grade 8, 1/4-20 UNC-2 thread, torque to 16 Nm (12 ft-lbs) Omit Standard Valve S3** Soft Shift, Orifice S4** Soft Shift, Orifice S7** Soft Shift, Orifice I7* Monitor Switch Direct Op. End Stroke I8* Monitor Switch * Single solenoid models only. Not CE or CS approved. Spools 8, 9, 81 & 82 not available. ** High watt coil only. Omit Standard Valve 5 Signal Lights 6 Manaplug, rad Harrison Mini 7 Manaplug, rad Harrison Micro (M12x1) 56 Manaplug (Mini) with Lights 57 Manaplug (Micro) with Lights (M12x1) 1 Manaplug (Mini) Single Sol. 5-in 1 Manaplug (Micro) Single Sol. 5-in (M12x1) 1C Manaplug (Mini) Single Sol. 5-in w/lights 1D Manaplug (Micro) Single Sol. 5-in w/lights (M12x1) 1M Manaplug Opposite Normal D3.indd, dd old: Designates ier I products and options. Non-old: Designates ier II products and options. hese products will have longer lead times. 55 Elyria, Ohio, US

58 echnical Information Series D3W Solenoid Ratings** Insulation Class H llowable Deviation DC, C Rect -10% to +15% from rated voltage C -5% to +5% rmature Wet pin type ** DC Solenoids available with optional molded metal oxide varistor (MOV) for surge suppression. Leadwire length 6 from coil face. D3W*****F Solenoid Electrical Characteristics Solenoid Nominal In Rush Holding Code Volts/Hz mps mps Watts KF 12 VDC JF 24 VDC ased on nominal 22 C (72 F) D3W Solenoid Electrical Characteristics Solenoid Nominal In Rush Holding Nominal Code Volts/Hz V V Watts (Ref) Y 120/ / / / E 24/ / K 12 VDC J 24 VDC D 120 VDC U 98 VDC Z 250 VDC DC holding amps. Explosion roof Solenoids D3W Rectified C Solenoid Electrical Characteristics Solenoid Nominal In Rush Holding Code Volts/Hz mps mps Watts Y 120/ /50 240/ /50 YF 120/ /50 F 240/ /50 ased on nominal 22 C (72 F) Explosion roof Solenoid Ratings U.L. /CS (EU) EX Class I, Div. 1 & 2, Groups C & D Class II, Div 1 & 2, Groups E, F & G s defined by the N.E.C. Complies with EX requirements for: Exd, Group II; EN50014: mds 1 & 2, EN50018: 200 Electrical Characteristics* ED and EU Solenoid Nominal In Rush Holding Nominal Code Volts/Hz V V Watts (Ref) Y 120/ / K 12 VDC J 24 VDC D 120 VDC * Dual frequency not available on explosion proof coils. DC holding amps. D3.indd, dd 56 Elyria, Ohio, US

59 Dimensions Series D3W Inch equivalents for millimeter dimensions are shown in (**) Hirschmann, Double C Solenoid Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. Hirschmann, Single C Solenoid Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. D3.indd, dd 57 Elyria, Ohio, US

60 Dimensions Series D3W Inch equivalents for millimeter dimensions are shown in (**) Conduit Cavity, Double DC Solenoid Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. Conduit Cavity, Single DC Solenoid Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. D3.indd, dd 58 Elyria, Ohio, US

61 Dimensions Series D3W Inch equivalents for millimeter dimensions are shown in (**) Conduit ox, Single C Solenoid with Variation 6 (Manaplug) & Variation (Extended Manual Override) Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. Conduit ox, Double DC Solenoid with Variation 6 (Manaplug) & Variation (Extended Manual Override) Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. D3.indd, dd 59 Elyria, Ohio, US

62 Dimensions Series D3W Inch equivalents for millimeter dimensions are shown in (**) Explosion roof U.L. & CS, Double Solenoid Note: Mounting bolts included with valve. Explosion roof EX, Double Solenoid M20 x 1.5-6H Metric hread olthole Centerline Reference Ground Stud (5.31) (4.08) 36.0 (1.42) 18.9 (0.74) Ref (0.74) 11.6 (0.46) 23.0 olthole 23.0 (0.91) 12.1 Centerline (0.91) 58.1 (0.47) Reference 75.6 (2.98) (2.29) (6.07) Note: Mounting bolts included with valve. D3.indd, dd (0.44) 76.7 (3.02) 64.9 (2.56) (8.18) Elyria, Ohio, US

63 Dimensions Series D3W Inch equivalents for millimeter dimensions are shown in (**) Hirschmann, Single C Solenoid with Variation I7 (Monitor Switch) Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. Monitor Switch (Variation I7) End of Stroke his feature provides for electrical confirmation of the spool shift. his can be used in safety circuits, to assure proper sequencing, etc. Switch Data Inductive switch requiring volt input. Outputs and are opposite; one at 0 voltage, the other at input voltage. During switching, and outputs reverse. rovides 0.4 switching current. For repetitive switch power-up conditions, please consult factory. D3.indd, dd 61 Elyria, Ohio, US

64 ccessories Series D3W Conduit ox (connection option K) Interface cm (6.0 inch) lead wires, 18 awg. Meets NEM 4 and I65 Manaplug (valve variations 6, 56, 1, 1C) Interface rad Harrison lug 3-in for Single Solenoid 5-in for Double Solenoid Ground Wire #1 (Green) Solenoid (Negative) Wire #3 (Red/lack) Solenoid (ositive) Wire #2 (Red/White) 3-in Manaplug (Mini) with Lights Single Solenoid Valves Installed Opposite Side of Solenoid ins are as seen on valve (male pin connectors) Hirschmann lug with Lights (5) Manaplug - Micro Connector (valve variations 7, 57, 1, 1D) in #3 (Ground) in #2 (ositive) in #1 (Negative) Face View of lug Conforms to DIN43650, ISO4400, Form 3-in ins are as seen on valve (male pin connectors) D3.indd, dd 62 Elyria, Ohio, US

65 echnical Information Series D3DW General Description Series D3DW directional control valves are high performance, 5-chamber, direct operated, wet armature, solenoid controlled, 3 or 4-way valves. hey are available in 2 or 3-position and conform to NF s D05, CEO 5 mounting patterns. Features 22 spools available including proportional. DC surge suppression available to protect electrical equipment. Easy access mounting bolts. CS approved. No tools required for coil removal. High pressure tank line capability. Monitor switch available. Response ime (ms) Signal to 95% spool stroke measured at 175 ar (2500 SI) and 75 LM (20 GM) Solenoid ype ull-in Drop-Out DC Solenoid Ratings** Insulation Class H llowable Deviation DC only from rated voltage -10% to +15% rmature Wet pin type ** DC Solenoids available with optional molded metal oxide varistor (MOV) for surge suppression. D3DW Solenoid Electrical Characteristics Solenoid Nominal In Rush Holding Nominal Code Volts mps mps Watts (Ref) K 12 VDC J 24 VDC D 120 VDC Y* 120/ /50 * 240/ /50 * C input rectified to DC Specifications Interface NF D05, CEO 5, NG 10 Max. Operating,, : ressure 345 ar (5000 SI) Standard CS 207 ar (3000 SI) ank: 207 ar (3000 SI) Standard CS 103 ar (1500 SI) Maximum Flow See Spool Reference Chart Leakage Rates Maximum llowable: cc (1.2 Cu. in.) per Minute/ 49 C (120 F) 69 ar (1000 SI)* 73.8 cc (4.5 Cu. in.) per Minute/ 207 ar (3000 SI)* ypical: 4.9 cc (0.3 Cu. in.) per Minute/ 69 ar (1000 SI)* 26.2 cc (1.6 Cu. in.) per Minute/ 345 ar (5000 SI) * #008 and #009 Spools may exceed these rates, consult factory. D3.indd, dd 63 Elyria, Ohio, US

66 Ordering Information Series D3DW D 3 Directional Control Valve asic Valve D ody W ctuator Spool Style Seal Solenoid Voltage Code Symbol Code Symbol * * 8* 30** 9** NF D05 CEO 5 NG 10 5-Chamber ody Wet armature solenoid * 8, 20 & 26 spools have closed crossover. ** 9 & 30 spools have open crossover. Valve schematic symbols are per NF/NSI standards, providing flow to when energizing solenoid. Note operators reverse sides for #8 and #9 spools. See installation information for details. Code N V Description Nitrile Fluorocarbon K 12 VDC J 24 VDC D 120 VDC Y* 120/60 C 110/50 * 240/60 C 220/50 * Must be rectified. Symbol b Single solenoid, 2 position, * spring offset. to and to in offset position C Double solenoid, 3 position, spring centered. D Double solenoid, 2 position, detent Single solenoid, 2 position, E spring centered. to and to when energized. Single solenoid, 2 position. Spring offset, F energized to center. osition spool spacer on side. to and to in spring offset position. Single solenoid, 2 position, H* spring offset. to and to in offset position. Single solenoid, 2 position. K Spring centered. to and to when energized. Single solenoid, 2 position, spring offset, energized M to center position. Spool spacer on side. to and to in spring offset position. * Only spools 20, 26 & 30. Only spools 20 & 30. his condition varies with spool code. b b b b a a a a a D3.indd, dd old: Designates ier I products and options. Non-old: Designates ier II products and options. hese products will have longer lead times. 64 Elyria, Ohio, US

67 Ordering Information Series D3DW Solenoid Connector Manual Override Options Electrical Options Shift Indication pprovals Variations Design Series NOE: Not required when ordering. Hirschmann w/lug W* Hirschmann w/o lug * Not available with signal lights. Omit Standard Valve 5 Signal Lights Omit Standard Valve 4 CS pproval Omit Standard Valve I7* Monitor Switch * Single solenoid models only. Not CE or CS approved. Not available with spools 8, 9, 81 & 82. Code Omit Description Standard ube Extended Manual Override Omit No Option V# Varistor Surge Suppresor Z C Rectified with MOV # DC Voltage only. Mounting olt Kits UNC olt Kits for use with D3DW & Sandwich Valves Number of Sandwich 2.00 (50mm) thickness D3DW Standard: K98 K141 K142 K Metric: KM98 KM141 KM142 KM143 40mm 90mm 140mm 190mm NOE: ll bolts are SE grade 8, 1/4-20 UNC-2 thread, torque to 16 Nm (12 ft-lbs). Valve Weight: Single Solenoid Double Solenoid Seal Kit: Nitrile Fluorocarbon 5.3 kg (11.6 lbs.) 7.3 kg (16.0 lbs.) SKD3DW SKD3DWV old: Designates ier I products and options. D3.indd, dd Non-old: Designates ier II products and options. hese products will have longer lead times. 65 Elyria, Ohio, US

68 Dimensions Series D3DW Inch equivalents for millimeter dimensions are shown in (**) Hirschmann, Double DC Solenoid 36.0 (1.42) 83.0 (3.27) (4.18) 87.8 (3.46) 58.9 (2.29) 12.0 (0.47) 23.0 (0.91) 21.5 (0.85) 80.1 (3.16) (4.83) 76.2 (3.00) (6.98) Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. Hirschmann, Single DC Solenoid 83.0 (3.27) 88.2 (3.48) 36.0 (1.42) See Note 58.0 (2.29) 23.0 (0.91) 12.0 (0.47) (4.83) 40.5 (1.60) 21.5 (0.85) 76.2 (3.00) 87.9 (3.46) Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. D3.indd, dd 66 Elyria, Ohio, US

69 Dimensions Series D3DW Inch equivalents for millimeter dimensions are shown in (**) Hirschmann, Single DC Solenoid with Variation I7 (Monitor Switch) Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. Monitor Switch (Variation I7) End of Stroke his feature provides for electrical confirmation of the spool shift. his can be used in safety circuits, to assure proper sequencing, etc. Switch Data Inductive switch requiring volt input. Outputs and are opposite; one at 0 voltage, the other at input voltage. During switching, and outputs reverse. rovides 0.4 switching current. For repetitive switch power-up conditions, please consult factory. D3.indd, dd 67 Elyria, Ohio, US

70 echnical Information Series D3 General Description Series D3 directional control valves are high performance, 4-chamber, direct operated, air pilot controlled, 4-way valves. hey are available in 2 or 3-position and conform to NF s D05/CEO 5 mounting patterns. Features Low pilot pressure required 4.1 ar (60 SI) minimum. High flow, low pressure drop design. Specifications Mounting attern NF D05, CEO 5, NG 10 Maximum Operating: 345 ar (5000 SI) ressure ank Line: 34 ar (500 SI) Maximum Flow See Spool Reference Chart ilot ressure ir Minimum 4.1 ar (60 SI) ir Maximum 6.9 ar (100 SI) ir Operated Shift Volume. he air pilot chamber requires a volume of 1.8 cc (.106 in. 3 ) for complete shift from center to end. ilot iston. he pilot piston area is 506 mm 2 (.785 in. 2 ). ilot piston stroke is 3.4 mm (.135 in.). Response ime* (ms) Signal to 95% spool stroke measured at 172 ar (2500 SI) and 75 LM (20 GM) ilot ressure ull-in Drop-Out 60 SI 23.0 ms 23.0 ms 100 SI 19.0 ms 38.0 ms * Chart is for reference only. Response time will vary with pilot line size, length, air pressure and air valve flow capacity (Cv). D3.indd, dd 68 Elyria, Ohio, US

71 Ordering Information Series D3 D 3 Directional Control Valve asic Valve ctuator Spool Style Seal Variations NF D05 CEO 5 NG10 ir Operator Omit Standard 90 1/4 S ilot ort Design Series NOE: Not required when ordering. Code Symbol Code Symbol 1 20* Code N V Description Nitrile Fluorocarbon * 82 9 * 8 and 20 spools have closed crossover. 9 and 30 are open crossover. Valve schematic symbols are per NF/NSI standards, providing flow to when energizing operator. Note operators reverse sides for #8 and #9 spools. See installation information for details. Symbols Single operator, two position b # spring offset. to and to in offset position. Double operator, b C three position, spring centered. Double operator, b D # two position, detent. wo position, spring centered. b E to and to in shifted position. Single operator, two position, H # spring offset. to and to in offset position. wo position, spring centered. K to and to in shifted position. a a a a #, D & H styles available with 20 and 30 spools only. Indicates air pilot. his condition varies with spool code. Mounting olt Kits UNC olt Kits for use with D3 & Sandwich Valves Number of Sandwich 2.00 (50mm) thickness D3 Standard: K98 K141 K142 K Metric: KM98 KM141 KM142 KM143 40mm 90mm 140mm 190mm NOE: ll bolts are SE grade 8, 1/4-20 UNC-2 thread, torque to 16 Nm (12 ft-lbs). old: Designates ier I products and options. D3.indd, dd Valve Weight: Seal Kit: Nitrile Fluorocarbon 4.1 kg (9 lbs.) SKD3 SKD3V Non-old: Designates ier II products and options. hese products will have longer lead times. 69 Elyria, Ohio, US

72 Dimensions Series D3 Inch equivalents for millimeter dimensions are shown in (**) ir Operated, Double ilot Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. ir Operated, Single ilot D3.indd, dd Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. 70 Elyria, Ohio, US

73 echnical Information Series D3C, D3D General Description Series D3C and D3D directional control valves are high performance, 4-chamber, direct operated, cam controlled, 3 or 4-way valves. hey are available in 2-position and conform to NF s D05, CEO 5 mounting patterns. Features Choice of 2 cam roller positions (D3C and D3D). Short stroke option. High flow, low pressure drop design. Specifications Mounting attern NF D05, CEO 5, NG 10 Maximum Operating: 345 ar (5000 SI) ressure ank Line: 34 ar (500 SI) Maximum Flow See Spool Reference Chart Force Required 235 N (53 lbs.) to Shift Maximum 30 Cam ngle Ordering Information Directional Control Valve D3.indd, dd D 3 asic Valve ctuator Spool Style Seal Variations NF D05 CEO 5 NG10 Code N Nitrile Omit V Fluorocarbon 5 C Cam (90 to mounting surface) D Cam parallel to mounting surface Symbol wo position, Code Symbol spring offset operator at port end. 20* wo position, H spring offset operator at port end. 30 Valve schematic symbols are per NF/NSI standards. See installation information for details. * 20 spool has closed crossover. 30 spool has open crossover. old: Designates ier I products and options. Valve Weight: Seal Kit: Nitrile Fluorocarbon Description Standard Short Stroke Design Series NOE: Not required when ordering. 3.6 kg (8 lbs.) SKD3C SKD3CV Non-old: Designates ier II products and options. hese products will have longer lead times. 71 Elyria, Ohio, US

74 echnical Information Series D3C,D3D Mounting olt Kits UNC olt Kits for use with D3C & D3D & Sandwich Valves Number of Sandwich 2.00 (50mm) thickness D3C, D3D Standard: K98 K141 K142 K Metric: KM98 KM141 KM142 KM143 40mm 90mm 140mm 190mm NOE: ll bolts are SE grade 8, 1/4-20 UNC-2 thread, torque to 16 Nm (12 ft-lbs) Dimensions Inch equivalents for millimeter dimensions are shown in (**) Cam Operated Full Valve ype re-ravel Spool Over-ravel ravel Standard Valve (0.07) (0.23) (0.08) Short Stroke (0) (0.16) (0.08) Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. D3.indd, dd 72 Elyria, Ohio, US

75 echnical Information Series D3L General Description Series D3L directional control valves are high performance, 4-chamber, direct operated, lever controlled, 4-way valves. hey are available in 2 or 3-position and conform to NF s D05, CEO 5 mounting patterns. Features Spring return or detent styles available. High flow, low pressure drop design. Heavy duty handle design. Specifications Mounting attern NF D05, CEO 5, NG 10 Maximum Operating: 345 ar (5000 SI) ressure ank Line: 34 ar (500 SI) Maximum Flow See Spool Reference Chart Force Required to Shift Lever 173 N (39 lbs.) Operator Dimensions Inch equivalents for millimeter dimensions are shown in (**) Lever Operated D3L Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. D3.indd, dd 73 Elyria, Ohio, US

76 Ordering Information Series D3L D 3 Directional Control Valve asic Valve Operator Spool Style Seal Variations ype & Location NF D05 CEO 5 NG10 Operator Location ( or End) Code Operator ype For Valve Style C D E H K N L Lever (Standard) L Lever (lternate) N/ N/ Code N V Description Nitrile Fluorocarbon Design Series NOE: Not required when ordering. Omit Standard I7* Monitor Switch * Not available on C, D or N styles. Not CE or CS approved. Code Symbol Code Symbol 1 20* * 82 9 * 8 and 20 spools have closed crossover. 9 and 30 are open crossover. Valve schematic symbols are per NF/NSI standards, providing flow to when energizing operator. Note operators reverse sides for #8 and #9 spools. See installation information for details. Symbol wo position, spring offset. * to and to in offset position. C hree position, spring centered. D* wo position, detent. wo position, spring centered. E to and to in shifted position. wo position, spring offset. H* to and to in offset position. wo position, spring centered. K to and to in shifted position. N hree position, detent. * 20 and 30 spools only. Mounting olt Kits UNC olt Kits for use with D3L & Sandwich Valves Number of Sandwich 2.00 (50mm) thickness D3L Standard: K98 K141 K142 K Metric: KM98 KM141 KM142 KM143 40mm 90mm 140mm 190mm NOE: ll bolts are SE grade 8, 1/4-20 UNC-2 thread, torque to 16 Nm (12 ft-lbs). his condition varies with spool code. Valve Weight: Seal Kit: Nitrile Fluorocarbon 3.6 kg (8 lbs.) SKD3L SKD3LV D3.indd, dd old: Designates ier I products and options. Non-old: Designates ier II products and options. hese products will have longer lead times. 74 Elyria, Ohio, US

77 Installation Information Series D3 Fluid Recommendations remium quality hydraulic oil with a viscosity range between cst ( SSU) at 38 C (100 F) is recommended. he absolute operation viscosity range is from cst ( SSU). Oil should have maximum anti-wear properties and rust and oxidation treatments. Fluids and Seals Valves using synthetic, fire-resistant fluids require special seals. When phosphate ester or its blends are used, fluorocarbon seals are required. Waterglycol, water-in-oil emulsions, and petroleum oil may be used with NIRILE seals. emperature Recommendation Recommended oil temperature: -29 C to +71 C (-20 F to +160 F) Filtration For maximum valve and system component life, the system should be protected at a contamination level not to exceed 125 particles greater than 10 microns per milliliter of fluid. (SE Class 4 or better, ISO Code 16/13). ank Line Surges If several valves are piped with a common tank line, flow surges in the line may cause unexpected spool shift. Detent style valves are most susceptible to this. Separate tank lines should be used when line surges are expected in an application. Recommended Mounting osition Valve ype Detent (Solenoid) Spring Offset Spring Centered D3.indd, dd Recommended Mounting osition Horizontal Unrestricted Unrestricted Silting Silting can cause any sliding spool valve to stick and not spring return, if held shifted under pressure for long periods of time. he valve should be cycled periodically to prevent sticking. Single ass Operation Valve flow ratings are for double pass operation (with equal flow in both paths). When using these components in single pass applications, flow capabilities may be reduced. Consult your local arker representative for details. Flow ath Data D3* Operator Operator *Note: On valves with 008 or 009 spool, and/or operators reverse sides. Flow paths remain the same as viewed from top of valve. Double Solenoid. With solenoid energized, flow path is and. When solenoid is energized, flow path is and. he center condition on a spring-centered valve exists when both coils are de-energized, or during a complete shift, as the spool passes through center. Detent and Spring Offset. he center condition exists on detent and spring offset valves only during spool crossover. o shift and hold a detented spool, only a momentary energizing of the solenoid is necessary. he minimum duration of the signal is aproximately 0.13 seconds for both C and DC voltages. his position will be held provided the spool center line is in a horizontal plane, and no shock or vibration is present to displace the spool. Single Solenoid. Spring offset valves can be ordered in six styles:, E, F, H, K and M. Flow path data for the various styles are described in the order chart. Lever Operated (on end) ull lever away from valve ; ush lever toward valve ; Note: Reverse with a #8 or #9 spool. Electrical Failure Should electric power fail, spring offset and spring centered valves will shift to the spring held position. Detented valves will stay in the last position held before power failure. If main flow does not fail or stop simultaneously, machine actuators may continue to function in an undesirable manner or sequence. Loss of ilot ressure (D3) Should a loss of pilot pressure occur, spring offset and spring centered valves will shift to the spring held position. Detented valves will remain in the last position held. If main hydraulic flow does not simultaneously stop, machine actuators may continue to function in an undesirable manner or sequence. orque Specifications orque values recommended for the bolts which mount the valve to the manifold or subplate are as follows: 1/4-20 thread (M6x1) torque 16.0 Nm (12 ft-lbs). 75 Elyria, Ohio, US

78 Installation Information Series D3 Mounting attern NF, D05, CEO 5, NG 10 Inch equivalents for millimeter dimensions are shown in (**) 21.4 (0.84) 50.8 (2.00) 27.0 (1.06) 6.4 (0.25) 54.0 (2.13) 37.3 (1.47) 16.7 (0.66) 3.2 (0.13) (3.62) 75.0 (2.95) 46.0 (1.81) (1.28) O11.2 (0.441) max.... & ports 0.56 L (0.022) ¼ 20 UNC 2 (M6 x 1) th'd x 9.7 (0.38) min. th'd depth 4 places 0.28 S (0.011) D3.indd, dd 76 Elyria, Ohio, US

79 Catalog HY /US Introduction pplication Series D31 hydraulic directional control valves are high performance, solenoid controlled, pilot operated, 2-stage, 4-way valves. hey are available in 2 or 3-position styles and are manifold mounted. hese valves conform to NF s D05H, CEO 5 and can also be manufactured to an NF DO5HE, CEO 5H configuration. Operation Series D31 directional valves consist of a 5-chamber style main body, a case hardened sliding spool, and a pilot valve or pilot operators (hydraulic or pneumatic). Series D31 Features Easy access mounting bolts. 345 ar (5000 SI) pressure rating. Flows to 175 LM (45 GM) depending on spool. Choice of four operator styles. Rugged four land spools. Low pressure drop. hosphate finish. oth NF and CEO mounting styles available. D31*W Solenoid Operated lug-in Conduit ox D31*L Lever Operated D3* Oil ilot Operated D31* ir ilot Operated D31.indd, dd 78 Elyria, Ohio, US

80 echnical Information Series D31 General Description Series D31 directional control valves are 5-chamber, pilot operated, solenoid controlled valves. he valves are suitable for manifold or subplate mounting. Features World design vailable worldwide. Mounting bolts below center line of spool Minimizes spool binding. Five chamber style Eliminates pressure spikes in tubes, increasing valve life. High pressure and flow ratings Increased performance options in a compact valve. Specifications Mounting attern NF D05H, CEO 5 NF D05HE, CEO 5H Max. Operating 345 ar (5000 SI) Standard ressure 207 ar (3000 SI) 10 Watt CS 207 ar (3000 SI) Max. ank Line Internal Drain Model: ressure 103 ar (1500 SI) C Std. 207 ar (3000 SI) DC Std./C Opt. External Drain Model: 207 ar (3000 SI) CS 103 ar (1500 SI) Max. Drain 103 ar (1500 SI) C only ressure 207 ar (3000 SI) DC Std./C Opt. CS 103 ar (1500 SI) Min. ilot ressure 6.9 ar (100 SI) Max. ilot ressure 345 ar (5000 SI) Standard CS 207 ar (3000 SI) Nominal Flow 76 Liters/Min (20 GM) Maximum Flow See Switching Limit Charts Response ime Response time (milliseconds) at 345 ar (5000 SI) is 76 LM (20 GM) Solenoid ilot ype ressure ull-in Drop-Out DC C Switching Limit Charts SI ar For Styles F and M external drain only (For internal drain see note below) 6.9 ar (100 SI) pilot 2,7 (14) 1, 3, (15), 4, 5 (16), 6, 11 Supply ressure with 150 SI ilot 0 LM 0 GM Flow Note: Internal Drain 1, 4 spools 113 LM (30 GM) max., 2, 9 & 14 spools per curve ll others 95 LM (25 GM) max. D31.indd, dd 79 Elyria, Ohio, US

81 Ordering Information Series D31 D Directional Control Valve asic Valve ctuator Spool Style ilot Supply Seal Solenoid and Drain Voltage 31D NF D05HE, CEO 5H, DIN NG10, D03 ilot, ISO ort 31V NF D05H, CEO 5, D03 ilot, NF ort Code Symbol Code Symbol * ** 008* ** D31.indd, dd W# Solenoid, Wet in, Screw-in HW# Reversed Wiring # Valve schematic symbols are per NF/ NSI standards, providing flow to when energizing solenoid. Note operators reverse sides for #008 and #009 spools. See installation information for details. o configure per DIN standards ( coil over port, coil over port) code valves as D31VHW***. * 008 & 020 spools have closed crossover. ** 009 & 030 spools have open crossover. Code N V Description Nitrile Fluorocarbon Code ** D G J K N*** *** Q** QD Symbol * Single solenoid, 2 position, spring offset. to and to in offset position. b C Double solenoid, 3 position, spring centered. D* Double solenoid, 2 position, detent. E Single solenoid, 2 position, spring centered. to and to when energized. F Single solenoid, 2 position, spring offset, energized to center. Spacer on side. to and to in offset position. H* Single solenoid, 2 position, spring offset. to and to in offset position. K 1* Internal ilot, External Drain 2* External ilot, External Drain 4# Internal ilot, Internal Drain 5 External ilot, Internal Drain * F and M style available only with external drain. # Not available with 002, 007, 008, 009 or 014 spools. Single solenoid, 2 position, spring centered. to and to when energized. M Single solenoid, 2 position, spring offset, energized to center. Spacer on side. to and to in offset position. * 020 and 030 spools only. High watt only. old: Designates ier I products and options. b Description 24/50 VC 120 VDC 198 VDC 24 VDC 12 VDC 220/50 VC 110/50 VC 100/60 VC 100 VC/60 Hz 100 VC/50 Hz 24/60 VC 240/60-220/50 VC 98 VDC 120/60-110/50 VC 250 VDC R U Y Z ** High watt only. *** Explosion proof only. vailable in DIN only. b b b Non-old: Designates ier II products and options. hese products will have longer lead times. a a a a a 80 Elyria, Ohio, US

82 Ordering Information Series D31 Valve Weight: Double Solenoid 5.4 kg (12.0 lbs.) Seal Kit: Nitrile SKD31VWN91 Fluorocarbon SKD31VWV91 D31.indd, dd Solenoid Connection C* Leadwire Conduit ox D** Metric lug (M12X1), DESIN E Explosion roof G lug-in Conduit ox J# Deutsch (D06-2S) M# Metri-ack (150) DIN with lug S# Dual Spade W DIN w/o lug * No variations See lug-in. ** DC only, lights, diode surge suppressor, not CS approved. Not available with lights. Required for variations on conduit box style. Must have lights. # DC only, no lights, not CS approved. Coil Options Code Omit Omit* High Watt D** Explosion roof, EEXD EX E** Explosion roof, EEXME EX F Low Watt L 10 Watt O** Explosion roof, MSH # Explosion roof, Ex d IIC EX/CS U ** Explosion roof, UL/CS * C ambient temperature must not exceed 60 C (140 F). ** 60 Hz only on C, no options. C only. DC and C rectified only. # J, K and Y voltages only. Dual frequency on C, no options. ube Options Manual Override Options Omit Standard Extended with oot None DC or C rectified only. Manual Override options not available with Explosion roof. Description Standard ressure ar (1500 SI) C 207 ar (3000 SI) DC H* High ressure, C only 207 ar (3000 SI) * Not available with CS. Electrical Options Omit No Options J* Diode Surge Suppressor Z Rectified Coil * DC only. DIN coil must include plug with lights. DC tube standard. Mounting olt Kits Shift pprovals Response and Indication Code Omit Valve Variations See next page for Valve Variations Design Series NOE: Not required when ordering. Omit Standard Valve 3* CS US 4*# CS pproved * Not available with C high pressure tube. # Valve is derated with this option., C, H styles only. J, K, Y, U voltages only with C, G, W solenoid connections only. Conforms to UL429. UNC olt Kits for use with D31*W & Sandwich Valves Number of Sandwich 2.00 (50mm) thickness D31*W Standard: K98 K141 K142 K Metric: KM98 KM141 KM142 KM143 40mm 90mm 140mm 190mm NOE: ll bolts are SE grade 8. Standard bolts are 1/4-20 UNC thread. Metric bolts are M6-1.0 thread. orque to 16 Nm (12 ft-lbs). old: Designates ier I products and options. Description Standard Response, No Switch Monitor Switch, & ort End Monitor Switch, & ort Start Non-old: Designates ier II products and options. hese products will have longer lead times. I3 I6 Note: Not CE or CS approved. Spools 008, 009, 081 and 082 not available. 81 Elyria, Ohio, US

83 Ordering Information Series D31 Valve Variations 5* Signal Lights Standard Signal Lights Hirsch. (DIN with lug) 7** Manaplug rad Harrison (12x1) Micro with Lights 56** Manaplug (Mini) with Lights 20 Fast Response 1C** Manaplug (Mini) Single Sol. 5-pin, with Lights 1D** Manaplug (Micro) Single Sol. 5-pin, with Lights 1G** Manaplug (Mini) Single Sol. 5-pin, with Stroke djust & End and Lights 1H** Manaplug (Micro) Single Sol. 5-pin, with Stroke djust & End and Lights 1M** Manaplug Opposite Normal 1 ainted ody 1R Stroke djust & End with ilot Choke Meter In 3 ilot Choke Meter Out 3 ilot Choke Meter In 3C ilot ressure Reducer 3D Stroke djust End 3E Stroke djust End 3F Stroke djust & End 3G* ilot Choke Meter Out with Lights 3H* ilot Choke Meter In with Lights 3J* ilot ressure Reducer with Lights 3K ilot Choke Meter Out with Stroke djust & End 3L** ilot Choke Meter Out, Stroke djust & End with Lights and Manaplug rad Harrison Mini 3M ilot Choke Meter Out, ilot ressure Reducer, Stroke djust & End 3R ilot Choke Meter Out & ilot ressure Reducer 3S** Lights, Mini Manaplug, ilot Choke Meter Out 7Y** M12x1 Manaplug (4-pin), Special Wiring, and Lights * DESIN, plug-in conduit box, and DIN with plug styles only. ** Must have plug-in style conduit box. D31.indd, dd 82 Elyria, Ohio, US

84 echnical Information Series D31 D31 Series ressure Drop vs. Flow he chart below provides the flow vs. pressure drop curve reference for the D31 Series valves by spool type. Example: Find the pressure drop at 76 LM (20 GM) for a D31 with a number 1 spool. o the right of spool number 1, locate the number 3 in the - column, and 2 in the - column. Using the graph at the bottom, locate curves 2 and 3 and read the pressure drop values. otal pressure drop through the valve is the sum of the two values. Note: ressure drops should be checked for all flow paths, especially when using non-symmetrical spools (003, 005, 007, 014, 015 and 016) and unbalanced actuators. D31 ressure Drop Reference Chart Curve Number Spool Shifted Center Condition No (-) (-) (-) (-) (-) (-) (-) erformance Curves Viscosity Correction Factor Viscosity (SSU) % of (pprox.) Curves were generated using 110 SSU hydraulic oil. For any other viscosity, pressure drop will change per chart. D31.indd, dd 83 Elyria, Ohio, US

85 Catalog HY /US echnical Information Solenoid Ratings Insulation System llowable Deviation from rated voltage rmature CS File Number Environmental Capability Class F -15% to +10% for DC and C rectified coils -5% to +5% for C Coils Wet pin type LR60407 DC Solenoids meet NEM 4 and I67 when properly wired and installed. Contact HVD for C coil applications. Series D31 Explosion roof Solenoid Ratings* U.L. & CS (EU) Class I, Div 1 & 2, Groups C & D Class II, Div 1 & 2, Groups E, F & G s defined by the N.E.C. MSH (EO) Complies with 30CFR, art 18 EX (ED) Complies with EX requirements for: Exd, Group II; EN50014: mds. 1 & 2, EN50018: 2000 EX & CS/US (E) Complies with EX EN , EN Ex d IIC; CS/US Ex d IIC, Ex d IIC for Class I, Zone 1, UL1203, UL1604, CS E61241,1 Class II, Div 1 * llowable Voltage Deviation ±10%. Note that Explosion roof C coils are single frequency only. Code Voltage In Rush mps In Rush Holding mps Watts Resistance Voltage ower mperage 3MM Code Code D L 120 VDC N/ N/ 0.09 mps 10 W ohms D Omit 120 VDC N/ N/ 0.26 mps 30 W ohms G Omit 198 VDC N/ N/ 0.15 mps 30 W ohms J L 24 VDC N/ N/ 0.44 mps 10 W ohms J Omit 24 VDC N/ N/ 1.32 mps 30 W ohms K L 12 VDC N/ N/ 0.88 mps 10 W ohms K Omit 12 VDC N/ N/ 2.64 mps 30 W 4.32 ohms L L 6 VDC N/ N/ 1.67 mps 10 W 3.59 ohms L Omit 6 VDC N/ N/ 5.00 mps 30 W 1.20 ohms Q Omit 100 VC / 60 Hz 2.05 mps 170 V 0.77 mps 30 W ohms QD F 100 VC / 60 Hz 1.35 mps 135 V 0.41 mps 18 W ohms QD F 100 VC / 50 Hz 1.50 mps 150 V 0.57 mps 24 W ohms R F 24/60 VC, Low Watt 6.67 mps 160 V 2.20 mps 23 W 1.52 ohms Omit 240/60 VC 0.83 mps 199 V 0.30 mps 30 W ohms Omit 220/50 VC 0.87 mps 191 V 0.34 mps 30 W ohms F 240/60 VC, Low Watt 0.70 mps 168 V 0.22 mps 21 W ohms F 220/50 VC, Low Watt 0.75 mps 165 V 0.26 mps 23 W ohms U L 98 VDC N/ N/ 0.10 mps 10 W ohms U Omit 98 VDC N/ N/ 0.31 mps 30W ohms Y Omit 120/60 VC 1.7 mps 204 V 0.60 mps 30 W ohms Y Omit 110/50 VC 1.7 mps 187 V 0.68 mps 30 W ohms Y F 120/60 VC, Low Watt 1.40 mps 168 V 0.42 mps 21 W ohms Y F 110/50 VC, Low Watt 1.50 mps 165 V 0.50 mps 23 W ohms Z L 250 VDC N/ N/ 0.04 mps 10 W ohms Z Omit 250 VDC N/ N/ 0.13 mps 30 W ohms Explosion roof Solenoids R 24/60 VC 7.63 mps 183 V 2.85 mps 27 W 1.99 ohms 240/60 VC 0.76 mps 183 V 0.29 mps 27 W 1.34 ohms N 220/50 VC 0.77 mps 169 V 0.31 mps 27 W 1.38 ohms Y 120/60 VC 1.60 mps 192 V 0.58 mps 27 W ohms 110/50 VC 1.47 mps 162 V 0.57 mps 27 W ohms K 12 VDC N/ N/ 2.75 mps 33 W 4.36 ohms J 24 VDC N/ N/ 1.38 mps 33 W ohms "E" Explosion roof Solenoids K 12 VDC N/ N/ 1.00 mps 12 W ohms J 24 VDC N/ N/ 1.00 mps 13 W ohms Y 120/60-50 VC N/ N/ 0.16 mps 17 W ohms D31.indd, dd 84 Elyria, Ohio, US

86 Dimensions Series D31 Inch equivalents for millimeter dimensions are shown in (**) Conduit ox, Double C Solenoid Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. Conduit ox and Stroke djust, Double C Solenoid D31.indd, dd Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. 85 Elyria, Ohio, US

87 Dimensions Series D31 Inch equivalents for millimeter dimensions are shown in (**) Conduit ox and ilot Choke Control, Double C Solenoid Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. Conduit ox, Single C Solenoid D31.indd, dd Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. 86 Elyria, Ohio, US

88 Dimensions Series D31 Inch equivalents for millimeter dimensions are shown in (**) Hirschmann and Stroke djust, Double DC Solenoid Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. Hirschmann and ilot Choke Control, Double DC Solenoid D31.indd, dd Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. 87 Elyria, Ohio, US

89 Dimensions Series D31 Inch equivalents for millimeter dimensions are shown in (**) Explosion roof U.L. and C.S.. pproved, Double Solenoid hase Out D31.indd, dd 88 Elyria, Ohio, US

90 Dimensions Series D31 Inch equivalents for millimeter dimensions are shown in (**) Explosion roof, EX d IIC EX/CS Single Solenoid Explosion roof, EEXD EX, Single Solenoid (5.14) (6.40) M20x1.5-6H hd. Ground Stud with Lock Washer 74.7 (2.94) 69.9 (2.75) 34.9 (1.38) (8.46) (7.25) 73.5 (2.90) (4.96) 83.0 (3.27) 62.0 (2.44) (8.84) 36.0 (1.42) 35.0 (1.38) 70.0 (2.76) D31.indd, dd 89 Elyria, Ohio, US

91 Dimensions Series D31 Inch equivalents for millimeter dimensions are shown in (**) lug-in Conduit ox, Double DC Solenoid lug-in Conduit ox, Single DC Solenoid D31.indd, dd 90 Elyria, Ohio, US

92 Dimensions Series D31 Inch equivalents for millimeter dimensions are shown in (**) lug-in Conduit ox, Double DC Solenoid with Variation I3 (Monitor Switch) Double Solenoid. With solenoid energized, flow path is and. When solenoid is energized, flow path is and. he center condition on a spring-centered valve exists when both coils are de-energized, or during a complete shift, as the spool passes through center. Monitor Switch (Variation I3 and I6) his feature provides for electrical confirmation of the spool shift. his can be used in safety circuits, to assure proper sequencing, etc. Switch Data in 1 and in 3 have outputs equal to the input. When the monitor switch has the output to in 1, in 3 will have an output of zero, and vice-versa. When the valve is switched, in 1 and in 3 will switch outputs. IN 2 Input VDC osition Control Switch Sensor / Driver Circuitry Load 0.2 Max IN 1 IN 3 Outputs D31.indd, dd 91 Elyria, Ohio, US

93 Catalog HY /US ccessories Manaplug (Options 6, 56, 1 & 1C) Interface rad Harrison lug 3-in for Single Solenoid 5-in for Double Solenoid Ground Wire #1 (Green) Series D31 Micro Connector Options (7, 7, 1 & 1D) Solenoid (Negative) Wire #3 (Red/lack) Solenoid (ositive) Wire #2 (Red/White) 3-in Manaplug (Mini) with Lights Single Solenoid Valves Installed Opposite Side of Solenoid ins are as seen on valve (male pin connectors) Manaplug Electrical Mini lug E E E in lug 5 in lug (Double Solenoid) 5 in lug (Single Solenoid) Conduit ox Option C No Wiring Options vailable Manaplug Electrical Micro lug E E E in lug 5 in lug (Double Solenoid) 5 in lug (Single Solenoid) Signal Lights (Option 5) lug-in Only LED Interface Meets Nema 4/I67 Hirschmann lug with Lights (Option 5) ISO 4400/DIN Form D31.indd, dd in #2 (ositive) Face View of lug in #3 (Ground) in #1 (Negative) DESIN Connector (Option D) M12 pin assignment Standard 1 = Not used 2 = Not used 3 = 0V 4 = Signal (24 V) 5 = Earth Ground ins are as seen on valve (male pin connectors) DESIN design in 1 and 2 connected Elyria, Ohio, US

94 echnical Information Series D31NW General Description Series D31NW valves are piloted by a D1VW valve. he valves can be ordered with position control. he minimum pilot pressure must be ensured for all operating conditions of the directional valve. dditionally spools with a to connection in the deenergized position need an external pressure supply (external inlet) or an integral check valve. Features World design vailable worldwide. Mounting bolts below center line of spool Minimizes spool binding. Five chamber style Eliminates pressure spikes in tubes, increasing valve life. High pressure and flow ratings Increased performance options in a compact valve. Dimensions Inch equivalents for millimeter dimensions are shown in (**) * lease add for each sandwich plate +40mm (1.58") (pressure reducing valve, pilot choke valve meter-in/-out). Surface Finish Seal K385 4x M6x40 DIN Nm (9.7 lb.-ft.) Nitrile: SK-D31NW-N-91 Fluorocarbon: SK-D31NW-V-91 he space necessary to remove the plug per DIN 43650, design type F is at least 15 mm. he torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm. D31.indd, dd 93 Elyria, Ohio, US

95 Ordering Information Series D31NW D Directional Control Valve 31N asic Valve W ctuator Solenoid Wet in Spool Style ilot Supply and Drain NF D05HE CEO 5H DIN NG10 D03 ilot, High flow Code Description 1 Internal ilot External Drain 2 External ilot External Drain 4* Internal ilot Internal Drain 5 External ilot Internal Drain * Not available with 002, 007, 009, 014, 030, 031, 032 spools. 3-osition Spools Code Spool ype a 0 b Code C E F K 3-osition Spools ll 3-osition Spools 3 positions. Spring offset in position 0. Operated in position a or b. Standard Spool ype 009 Operated in position a. Spring offset in position b. Operated in position b. Operated in position b. Spring offset in position a. Operated in position a. 2 positions. Spring offset in position 0. 2 positions. Operated in position 0. 2 positions. Spring offset in position M Spring offset in position a. Spring offset in position b. 2 positions. Operated in position R S No center in offset position. No center in offset position. No center in offset position. No center in offset position. 2 positions, detent. Operated in position 0 or b. 2 positions, detent. Operated in position 0 or a. No center in offset position. 2-osition Spools Code Spool ype a b Code D 2-osition Spools Spool osition Spring offset in position b. Operated in position a. Detent, operated in position a or b. No center or offset position. Weight: Single Solenoid: 7.6 kg (16.8 lbs.) Double Solenoid: 8.1 kg (17.9 lbs.) H Spring offset in position a. Operated in position b. D31.indd, dd old: Designates ier I products and options. Non-old: Designates ier II products and options. hese products will have longer lead times. 94 Elyria, Ohio, US

96 Ordering Information Series D31NW Seal N Nitrile V Fluorocarbon Solenoid Voltage Solenoid Connection Coil Options ube Options Manual Override Options Electrical Options Shift Response and Indication Valve Variations See next page Design Series NOE: Not required when ordering. * 24/50 VC D 120 VDC G 198 VDC J 24 VDC K 12 VDC N** 220/50 VC Q* 100/60 VC QD 100 VC/60 HZ 100 VC/50 HZ R 24/60 VC 240/60-220/50 VC U 98 VDC Y 120/60-110/50 VC Z 250 VDC * High Watt Coil only. ** Explosion roof only. vailable in DIN only. C* Leadwire Conduit ox D** Metric lug (M12X1), DESIN E Explosion roof G lug-in Conduit ox J# Deutsch (D06-2S) M# Metri-ack (150) DIN with lug S# Dual Spade W DIN w/o lug * No variations See lug-in. ** DC only, lights, diode surge suppressor, not CS approved. Not available with lights. Required for variations on conduit box style. Must have lights. # DC only, no lights, not CS approved. Code Omit Omit Standard Extended with oot None DC or C Rectified only. Manual Override options not available with Explosion roof. Description Standard ressure ar (1500 SI) C 207 ar (3000 SI) DC H* High ressure, C only 207 ar (3000 SI) * Not available with CS. Omit* High Watt D** Explosion roof, EEXD EX E** Explosion roof, EEXME EX F Low Watt L 10 Watt O** Explosion roof, MSH # Explosion roof, Ex d IIC EX/CS U ** Explosion roof, UL/CS * C ambient temperature must not exceed 60 C (140 F). ** 60 Hz only on C, no options. C only. DC and C rectified only. # J, K and Y voltages only. Dual frequency on C, no options. Code Omit I3N I6N Omit No Options J* Diode Surge Suppressor Z Rectified Coil * DC only. DIN coil must include plug with lights. DC tube standard. Description Standard Response, No Switch Monitor Switch, & ort End Monitor Switch, & ort Start Note: Not CE or CS approved. vailable in C style with 001, 003, , 021, and 022 spools only. D31.indd, dd old: Designates ier I products and options. Non-old: Designates ier II products and options. hese products will have longer lead times. 95 Elyria, Ohio, US

97 Ordering Information Series D31NW Valve Variations 5* Signal Lights Standard Signal Lights Hirsch. (DIN with lug) 7** Manaplug rad Harrison (12x1) Micro with Lights 56** Manaplug (Mini) with Lights 1C** Manaplug (Mini) Single Sol. 5-pin, with Lights 1D** Manaplug (Micro) Single Sol. 5-pin, with Lights 1G** Manaplug (Mini) Single Sol. 5-pin, with Stroke djust & End and Lights 1H** Manaplug (Micro) Single Sol. 5-pin, with Stroke djust & End and Lights 1M** Manaplug Opposite Normal 1R Stroke djust & End with ilot Choke Meter In 3 ilot Choke Meter Out 3 ilot Choke Meter In 3C ilot ressure Reducer 3D Stroke djust End 3E Stroke djust End 3F Stroke djust & End 3G* ilot Choke Meter Out with Lights 3H* ilot Choke Meter In with Lights 3J* ilot ressure Reducer with Lights 3K ilot Choke Meter Out with Stroke djust & End 3L** ilot Choke Meter Out, Stroke djust & End with Lights and Manaplug rad Harrison Mini 3M ilot Choke Meter Out, ilot ressure Reducer, Stroke djust & End 3R ilot Choke Meter Out & ilot ressure Reducer 3S** Lights, Mini Manaplug, ilot Choke Meter Out 7Y** M12x1 Manaplug (4-pin), Special Wiring, and Lights * DESIN, plug-in conduit box, and DIN with plug styles only. ** Must have plug-in style conduit box. D31.indd, dd 96 Elyria, Ohio, US

98 echnical Information Solenoid Ratings Insulation System llowable Deviation from rated voltage rmature CS File Number Environmental Capability Class F -15% to +10% for DC and C rectified coils -5% to +5% for C Coils Wet pin type LR60407 DC Solenoids meet NEM 4 and I67 when properly wired and installed. Contact HVD for C coil applications. Series D31NW Explosion roof Solenoid Ratings* U.L. & CS (EU) Class I, Div 1 & 2, Groups C & D Class II, Div 1 & 2, Groups E, F & G s defined by the N.E.C. MSH (EO) Complies with 30CFR, art 18 EX (ED) Complies with EX requirements for: Exd, Group II; EN50014: mds. 1 & 2, EN50018: 2000 EX & CS/US (E) Complies with EX EN , EN Ex d IIC; CS/US Ex d IIC, Ex d IIC for Class I, Zone 1, UL1203, UL1604, CS E61241,1 Class II, Div 1 * llowable Voltage Deviation ±10%. Note that Explosion roof C coils are single frequency only. Code Voltage In Rush mps In Rush Holding mps Watts Resistance Voltage ower mperage 3MM Code Code D L 120 VDC N/ N/ 0.09 mps 10 W ohms D Omit 120 VDC N/ N/ 0.26 mps 30 W ohms G Omit 198 VDC N/ N/ 0.15 mps 30 W ohms J L 24 VDC N/ N/ 0.44 mps 10 W ohms J Omit 24 VDC N/ N/ 1.32 mps 30 W ohms K L 12 VDC N/ N/ 0.88 mps 10 W ohms K Omit 12 VDC N/ N/ 2.64 mps 30 W 4.32 ohms L L 6 VDC N/ N/ 1.67 mps 10 W 3.59 ohms L Omit 6 VDC N/ N/ 5.00 mps 30 W 1.20 ohms Q Omit 100 VC / 60 Hz 2.05 mps 170 V 0.77 mps 30 W ohms QD F 100 VC / 60 Hz 1.35 mps 135 V 0.41 mps 18 W ohms QD F 100 VC / 50 Hz 1.50 mps 150 V 0.57 mps 24 W ohms R F 24/60 VC, Low Watt 6.67 mps 160 V 2.20 mps 23 W 1.52 ohms Omit 240/60 VC 0.83 mps 199 V 0.30 mps 30 W ohms Omit 220/50 VC 0.87 mps 191 V 0.34 mps 30 W ohms F 240/60 VC, Low Watt 0.70 mps 168 V 0.22 mps 21 W ohms F 220/50 VC, Low Watt 0.75 mps 165 V 0.26 mps 23 W ohms U L 98 VDC N/ N/ 0.10 mps 10 W ohms U Omit 98 VDC N/ N/ 0.31 mps 30W ohms Y Omit 120/60 VC 1.7 mps 204 V 0.60 mps 30 W ohms Y Omit 110/50 VC 1.7 mps 187 V 0.68 mps 30 W ohms Y F 120/60 VC, Low Watt 1.40 mps 168 V 0.42 mps 21 W ohms Y F 110/50 VC, Low Watt 1.50 mps 165 V 0.50 mps 23 W ohms Z L 250 VDC N/ N/ 0.04 mps 10 W ohms Z Omit 250 VDC N/ N/ 0.13 mps 30 W ohms Explosion roof Solenoids R 24/60 VC 7.63 mps 183 V 2.85 mps 27 W 1.99 ohms 240/60 VC 0.76 mps 183 V 0.29 mps 27 W 1.34 ohms N 220/50 VC 0.77 mps 169 V 0.31 mps 27 W 1.38 ohms Y 120/60 VC 1.60 mps 192 V 0.58 mps 27 W ohms 110/50 VC 1.47 mps 162 V 0.57 mps 27 W ohms K 12 VDC N/ N/ 2.75 mps 33 W 4.36 ohms J 24 VDC N/ N/ 1.38 mps 33 W ohms "E" Explosion roof Solenoids K 12 VDC N/ N/ 1.00 mps 12 W ohms J 24 VDC N/ N/ 1.00 mps 13 W ohms Y 120/60-50 VC N/ N/ 0.16 mps 17 W ohms D31.indd, dd 97 Elyria, Ohio, US

99 Specifications Series D31NW General Design Directional Spool Valve ctuation Solenoid Size NG10 Mounting Interface DIN / ISO 4401 / NF D05 / CEO R 121-H Mounting osition Unrestricted, preferably horizontal mbient emperature [ C] [ C] ; (-13 F F) (without inductive position control) ; (+32 F F) (with inductive position control) MF D Value [years] 75 Hydraulic Maximum Operating ressure ilot drain internal:,,, X 315 ar (4568 SI);, Y 140 ar (2030 SI) ilot drain external:,,,, X 315 ar (4568 SI); Y 140 ar (2030 SI) Fluid Hydraulic oil in accordance with DIN / Fluid emperature [ C] (-13 F F) Viscosity ermitted [cst]/[mm²/s] ( SSU) Recommended [cst]/[mm²/s] ( SSU) Filtration ISO 4406 (1999); 18/16/13 (meet NS 1638: 7) Flow Maximum 170 LM (45 GM) Leakage at 350 ar (per flow path) [ml/min] ( GM) (depending on spool) Minimum ilot Supply ressure 7 ar (102 SI) Static / Dynamic Step Response at 85% Energized De-energized DC Solenoids ilot ressure 50 ar & 100 ar [ms] ar & 350 ar [ms] C Solenoids ilot ressure 50, 100, 250 & 350 ar [ms] 30 / D31.indd, dd 98 Elyria, Ohio, US

100 Electrical Specifications Series D31NW osition Control M12x1 rotection Class I 65 in accordance with EN (plugged and mounted) mbient emperature [ C] ; (+32 F F) Supply Voltage / Ripple [V] ±10% Current Consumption without Load [m] 30 Max. Output Current per Channel, Ohmic [m] 400 Min. Output Load per Channel, Ohmic [kohm] 100 Max. Output Drop at 0.2 [V] 1.1 Max. Output Drop at 0.4 [V] 1.6 EMC EN / EN Max. olerance mbient Field Strength [/m] <1200 Min. Distance to Next C Solenoid [m] >0.1 Interface M12x1 per IEC Wiring Minimum [mm²] 5 x 0.25 brad shield recommended Wiring Length Maximum [m] 50 (164 ft.) recommended M12 in ssignment 1 + Supply V 2 Out : normally closed 3 0V 4 Out : normally open 5 Earth ground Definitions Start position monitored: he valve is de-energized. he inductive switch gives a signal at the moment (below 15% spool stroke) when the spool leaves the spring offset position. End position monitored: he inductive switch gives a signal before the end position is reached. (above 85% spool stroke). Delivery includes plug M12 x 1 (part no.: ). D31.indd, dd 99 Elyria, Ohio, US

101 echnical Information Series D31NW erformance Curves he flow curve diagram shows the flow versus pressure drop curves for all spool types. he relevant curve number for each spool type, operating position and flow direction is given in the table below. Spool Curve Number Code ll characteristic curves measured with HL46 at 50 C (122 F). Integral Check Valve in the port Mounting an integral check valve in the port is necessary to build up pilot pressure for valves with to connection and internal pilot oil supply. he pressure difference at the integral check valve (see performance curves) is to be added to all flow curves of the -port of the main valve. ilot Oil Inlet (Supply) and Outlet (Drain) D31.indd, dd ll orifice sizes for standard valves 100 Elyria, Ohio, US

102 ccessories Manaplug (Options 6, 56, 1 & 1C) Interface rad Harrison lug 3-in for Single Solenoid 5-in for Double Solenoid Ground Wire #1 (Green) Series D31NW Micro Connector Options (7, 7, 1 & 1D) Solenoid (Negative) Wire #3 (Red/lack) Solenoid (ositive) Wire #2 (Red/White) 3-in Manaplug (Mini) with Lights Single Solenoid Valves Installed Opposite Side of Solenoid ins are as seen on valve (male pin connectors) Manaplug Electrical Mini lug E E E in lug 5 in lug (Double Solenoid) 5 in lug (Single Solenoid) Conduit ox Option C No Wiring Options vailable Manaplug Electrical Micro lug E E E in lug 5 in lug (Double Solenoid) 5 in lug (Single Solenoid) Signal Lights (Option 5) lug-in Only LED Interface Meets Nema 4/I67 Hirschmann lug with Lights (Option 5) ISO 4400/DIN Form D31.indd, dd in #2 (ositive) Face View of lug in #3 (Ground) in #1 (Negative) DESIN Connector (Option D) M12 pin assignment Standard 1 = Not used 2 = Not used 3 = 0V 4 = Signal (24 V) 5 = Earth Ground ins are as seen on valve (male pin connectors) DESIN design in 1 and 2 connected Elyria, Ohio, US

103 echnical Information Series D31* General Description Series D31* directional control valves are 5-chamber, air pilot operated valves. he valves are suitable for manifold or subplate mounting. Features World design vailable worldwide. Mounting bolts below center line of spool Minimizes spool binding. Five chamber style Eliminates pressure spikes in tubes, increasing valve life. High pressure and flow ratings Increased performance options in a compact valve. Specifications Mounting attern NF D05H, CEO 5 NF D05HE, CEO 5H ressure Drop Chart Max. Operating ressure Max. ank Line ressure 345 ar (5000 SI) Internal Drain Model: 34 ar (500 SI) External Drain Model: 207 ar (3000 SI) Max. Drain ressure 34 ar (500 SI) Maximum Flow See Switching Limit Charts ilot ressure ir Min: 3.4 ar (50 SI) ir Max: 10.2 ar (150 SI) Response ime Varies with pilot line size and length, pilot pressure, pilot valve shift time & flow capacity (GM) VISCOSIY CORRECION FCOR Viscosity (SSU) % of (pprox.) Curves were generated using 100 SSU hydraulic oil. For any other viscosity, pressure drop will change as per chart. D31V ressure Drop Reference Chart -- Curve Number Spool Shifted Center Condition No (-) (-) (-) (-) (-) (-) (-) D31V ressure Drop vs. Flow he chart to the left provides the flow vs. pressure drop curve reference for the D31V Series valves by spool type. Example: Find the pressure drop at 76 LM (20 GM) for a D31V with a number 001 spool. o the right of spool number 001, locate the number 3 in the - column, and 2 in the - column. Using the top graph, locate curves 2 and 3 and read the pressure drop values. otal pressure drop through the valve is the sum of the two values. D31.indd, dd 102 Elyria, Ohio, US

104 echnical Information Series D31* Ordering Information D Directional Control Valve asic Valve 31D NF D05HE, CEO 5H (ISO) 31V NF D05H, CEO 5 Valve schematic symbols are per NF/NSI standards, providing flow to when energizing operator. Note operators reverse sides for #008 and #009 spools. See installation information for details. Valve Weight: Double Operator 5.7 kg (12.7 lbs.) Standard olt Kit: K98 Metric olt Kit: KM98 ir Operated ilot Code Symbol * * 008 and 020 spools have closed crossover. * 009 and 030 spools have open crossover. Spool Style ilot Supply Seal Valve and Drain Variations N Nitrile Omit Standard V Fluorocarbon 7 ilot Choke - Meter Out 8 Stroke dj. End 9 Stroke dj. End 1 Int. pilot/ext. drain 60 ilot choke - Meter In 2 Ext. pilot/ext. drain 89 Stroke dj. & Ends 4# Int. pilot/int. drain 90 1/4 Shreads 5 Ext. pilot/int. drain # Not available with 002, 008 & 009 spools. Single operator, 2 position, spring offset. to and to in offset position. C Double operator, 3 position, spring centered. D Double operator, 2 position, detent. E Single operator, 2 position, spring centered. to and to when energized. H Single operator, 2 position, spring offset. to and to in offset position. K Single operator, 2 position, spring centered. to and to when energized. old: Designates ier I products and options. b b b Symbol a a a Design Series NOE: Not required when ordering. Only spools 020 and 030. his condition varies with spool code. Non-old: Designates ier II products and options. hese products will have longer lead times. b a Dimensions ir Operated Inch equivalents for millimeter dimensions are shown in (**) D31.indd, dd Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. 103 Elyria, Ohio, US

105 echnical Information Series D31*L General Description Series D31*L directional control valves are 5-chamber, pilot operated, lever controlled valves. he valves are suitable for manifold or subplate mounting. Features World design vailable worldwide. Mounting bolts below center line of spool Minimizes spool binding. Five chamber style Eliminates pressure spikes in tubes, increasing valve life. High pressure and flow ratings Increased performance options in a compact valve. Specifications ressure Drop Chart Mounting attern NF D05H, CEO 5 NF D05HE, CEO 5H Max. Operating ressure Max. ank Line ressure Maximum Flow 345 ar (5000 SI) Internal Drain Model: 34 ar (500 SI) External Drain Model: 207 ar (3000 SI) See Switching Limit Charts ilot ressure Oil Min 6.9 ar (100 SI) Oil Max 345 ar (5000 SI) Max. Drain ressure 34 ar (500 SI) Response ime Varies with pilot line size and length, pilot pressure, pilot valve shift time & flow capacity (GM) VISCOSIY CORRECION FCOR Viscosity (SSU) % of (pprox.) Curves were generated using 100 SSU hydraulic oil. For any other viscosity, pressure drop will change as per chart. D31VL ressure Drop Reference Chart -- Curve Number Spool Shifted Center Condition No (-) (-) (-) (-) (-) (-) (-) D31VL ressure Drop vs. Flow he chart to the left provides the flow vs. pressure drop curve reference for the D31VL Series valves by spool type. Example: Find the pressure drop at 76 LM (20 GM) for a D31VL with a number 001 spool. o the right of spool number 001, locate the number 3 in the - column, and 2 in the - column. Using the top graph, locate curves 2 and 3 and read the pressure drop values. otal pressure drop through the valve is the sum of the two values. D31.indd, dd 104 Elyria, Ohio, US

106 echnical Information Series D31*L Ordering Information D L Directional Control Valve asic Valve 31D NF D05HE, CEO 5H (ISO) 31V NF D05H, CEO 5 Valve schematic symbols are per NF/NSI standards, providing flow to when energizing operator. Note operators reverse sides for #008 and #009 spools. See installation information for details. Lever Operated ilot Code ** 009* 020** 030* Symbol * 009 and 030 spools have open crossover. ** 008 and 020 spools have closed crossover. Valve Weight: 5.4 kg (12.0 lbs.) Standard olt Kit: K98 Metric olt Kit: KM98 Spool Style ilot Supply Seal and Drain 1 Int. pilot/ext. drain 2 Ext. pilot/ext. drain 4# Int. pilot/int. drain 5 Ext. pilot/int. drain # Not available with 002, 008 & 009 spools. Code N V Description Nitrile Fluorocarbon Sgl. operator, 2 position, spring offset. to and to in offset position. C Dbl. operator, 3 position, spring centered. D Dbl. operator, 2 position, detent. E Sgl. operator, 2 position, spring centered. to and to in shifted position. H Sgl. operator, 2 position, spring offset. to and to in offset position. K Sgl. operator, 2 position. Spring centered. to and to in shifted position. old: Designates ier I products and options. Valve Variations Symbol Design Series NOE: Not required when ordering. Omit Standard 7 ilot choke meter out 8 Stroke adj. End 9 Stroke adj. End 60 ilot choke meter in 89 Stroke adj. & Ends Only spools 020 and 030. his condition varies with spool code. Non-old: Designates ier II products and options. hese products will have longer lead times. Dimensions Lever Operated Inch equivalents for millimeter dimensions are shown in (**) Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve. D31.indd, dd 105 Elyria, Ohio, US

107 echnical Information Series D3* General Description Series D3* directional control valves are 5-chamber, oil pilot operated valves. he valves are suitable for manifold or subplate mounting. Features World design vailable worldwide. Mounting bolts below center line of spool Minimizes spool binding. High pressure and flow ratings Increased performance options in a compact valve. Specifications ressure Drop Chart Mounting attern NF D05H, CEO 5 NF D05HE, CEO 5H Max. Operating 345 ar (5000 SI) ressure Max. ank 207 ar (3000 SI) Line ressure ilot ressure Oil Min: 6.9 ar (100 SI) Oil Max: 345 ar (5000 SI) Varies with pilot line size and Response ime length, pilot pressure, pilot valve shift time & flow capacity (GM) D3 ressure Drop Reference Chart -- Curve Number Spool Shifted Center Condition No (-) (-) (-) (-) (-) (-) (-) VISCOSIY CORRECION FCOR Viscosity (SSU) % of (pprox.) Curves were generated using 100 SSU hydraulic oil. For any other viscosity, pressure drop will change as per chart. D3 ressure Drop vs. Flow he chart to the left provides the flow vs. pressure drop curve reference for the D3 Series valves by spool type. Example: Find the pressure drop at 76 LM (20 GM) for a D3 with a number 1 spool. o the right of spool number 1, locate the number 3 in the - column, and 2 in the - column. Using the top graph, locate curves 2 and 3 and read the pressure drop values. otal pressure drop through the valve is the sum of the two values. D31.indd, dd 106 Elyria, Ohio, US

108 echnical Information Series D3* Ordering Information D Directional Control Valve asic Valve 3D NF D05HE, CEO 5H 3 NF D05H, CEO 5 * 9 and 30 spools have open crossover. ** 8 and 20 spools have closed crossover. Hydraulic ilot Code Valve Weight: Single Operator 1.4 kg (3.0 lbs.) Double Operator 1.6 kg (3.5 lbs.) Standard olt Kit: K98 Metric olt Kit: KM98 Seal Kit: Nitrile SKD3 Fluorocarbon SKD3V ** 9* 20** 30* Spool Style ilot Supply Seal and Drain Symbol Code N V 2 Ext. pilot/ext. drain 5# Ext. pilot/int. drain Description Nitrile Fluorocarbon # vailable on and H styles only. Single operator, 2 position, spring offset. to and to in offset position. C Double operator, 3 position, spring centered. H Single operator, 2 position, spring offset. to and to in offset position. Only spools 20 and 30. Omit Standard 7 ilot Choke Meter Out 8 Stroke dj. End 9 Stroke dj. End 60 ilot Choke Meter In 89 Stroke dj. & Ends Symbol his condition varies with spool code. Valve schematic symbols are per NF/NSI standards, providing flow to when energizing operator X. Note operators reverse sides for #8 and #9 spool. See installation information for details. old: Designates ier I products and options. Valve Variations Non-old: Designates ier II products and options. hese products will have longer lead times. Design Series NOE: Not required when ordering. Dimensions Oil Operated Inch equivalents for millimeter dimensions are shown in (**) 76.2 (3.00) 47.8 (1.88) # 6 SE (4.40) 83.0 (3.27) See Note 36.0 (1.42) D31.indd, dd 50.5 (1.99) (4.76) 47.2 (1.86) 58.9 (2.32) (4.76) 35.0 (1.38) Note: 30.0mm (1.18") from bottom of bolt home counterbore to bottom of valve. 107 Elyria, Ohio, US

109 Installation Information Series D31, D3* FOR MXIMUM VLVE RELIILIY, DHERE O HE FOLLOWING INSLLION INFORMION. he following is important installation information which applies to all directional control valves described in this catalog. Mounting osition Detent Horizontal Spring Offset Unrestricted Spring Centered Unrestricted Fluid Recommendations remium quality hydraulic oil with a viscosity range between cst. ( SSU) t 38 C (100 F) is recommended. he absolute operating viscosity range is from cst. ( SSU). Oil should have maximum anti-wear properties and rust and oxidation treatment. Fluids and Seals Valves using synthetic, fire-resistant fluids require special seals. When phosphate esters or its blends are used, FLUOROCRON seals are required. Waterglycol, water-in-oil emulsions and petroleum oil may be used with SNDRD seals. Filtration For maximum valve and system component life, the system should be protected from contamination at a level not to exceed 125 particles greater than 10 microns per milliliter of fluid (SE class 4/ISO 16/13). Silting Silting can cause any sliding spool valve to stick and not spring return if held under pressure for long periods of time. he valve should be cycled periodically to prevent sticking. Special Installations Consult your arker representative for any application requiring the following: ressure above rating. Fluid other than those specified. Oil temperature above 71.1 C (160 F). Flow path other than normal. Mounting atterns Series NF Size D31V*, D3 D05H, CEO 5 3/8" D31D*, D3D, D31NW D05HE, CEO 5H 3/8" orque Specifications he recommended torque values for the bolts which mount the valve to the manifold or subplate are as follows: 16.3 Nm (12 ft-lb). 1/16 ipe lug forvariations 1 & 4 orque to:11.67 ± 1.67 Nm (105 ± 15 in-lbs) 1/16 ipe lug forvariations 4 & 5 orque to:11.67 ± 1.67 Nm (105 ± 15 in-lbs) NF D05HE, CEO 5H attern D31DW 1/16 ipe lug forvariations 1 & 4 orque to:11.67 ± 1.67 Nm (105 ± 15 in-lbs) D31.indd, dd 108 1/16 ipe lug for Variations 4 & 5 orque to:11.67 ± 1.67 Nm (105 ± 15 in-lbs) NF D05H, CEO 5 attern D31VW Elyria, Ohio, US

110 Installation Information Series D31 SERIES D31*W, D31*, D31*L ILO OERED, DIRECIONL CONROL VLVES ank and Drain Line Surges If several valves are piped with a common tank or drain line, flow surges in the line may cause an unexpected spool shift. No spring style valves are most susceptible to this. Separate tank and drain lines should be piped in installations where line surges are expected. Electrical Failure or Loss of ilot ressure (D31*) Should electric power fail or loss of pilot pressure occur, spring offset and spring centered valves will shift to the spring held position. Detented valves will stay in the last position held before power failure. If main flow does not fail or stop at the same time power fails, machine actuators may continue to function in an undesirable manner or sequence. Electrical Characteristics (Detented Spool) Only a momentary energizing of the solenoid is necessary to shift and hold a detented spool. Minimum duration of the signal is 0.1 seconds for DC voltages. For C voltages the response time is 0.06 seconds. Spool position will be held provided the spool centerline is in a horizontal plane, and no shock or vibration is present to displace the spool. ilot/drain Characteristics ilot ressure: 6.9 to 345 ar (100 to 5000 SI) External: n oil source sufficient to maintain minimum pilot pressure must be connected to the X port of the main body. When using the external pilot variation, an M5 x 0.8 x 6mm long set screw must be present in the D31*W, D31*, D31*L Flow aths main body pilot passage. (For details see Dimension pages.) his plug will be furnished in valves ordered with pilot code 2 or 5. Internal: Flow is internally ported from the pressure port of the main valve body to the port of the pilot valve. he pressure developed at the port of the pilot valve must be 100 SI (6.9 ar) minimum at all times. If the valve center condition allows flow from pressure to tank, 100 SI (6.9 ar) back pressure must be developed in the tank line to ensure sufficient pilot force at. he X port in subplate must be plugged when using internal pilot variation (1/16 N). ilot Valve Drain: Maximum pressure 102 ar (1500 SI), 207 ar (3000 SI) optional. External: When using an external drain, an M6 x 1 x 10mm long set screw must be present in the main body drain passage. (For details see Dimension pages.) his plug will be furnished in valves ordered with drain code 1 or 2. Drain flow from the pilot valve is at the Y port of the main body and must be piped directly to tank. Maximum drain line pressure is 102 ar (1500 SI), 207 ar (3000 SI) optional. ny drain line back pressure is additive to the pilot pressure requirement. Internal: Drain flow from the pilot valve is internally connected to the main valve tank port. ank and drain pressure are then identical so tank line pressure should not exceed 102 ar (1500 SI), 207 ar (3000 SI) optional. ny tank line back pressure is also additive to the pilot pressure requirement. If flow surges (a cause of pressure surges) are anticipated in the tank line, an external drain variation is recommended. he Y port in subplate must be plugged when using internal drain variations. Style Description No Solenoid/Operator Solenoid/Operator Solenoid/Operator Code Energized Energized Energized Spring Offset and and C Spring Centered Centered and and D Detented Last osition Held and and E Spring Centered Centered and F Spring Offset, Shift to Center and Centered H Spring Offset and and K Spring Centered Centered and M Spring Offset, Shift to Center and Centered D31*W only. D31.indd, dd 109 Elyria, Ohio, US

111 Catalog HY /US Installation Information SERIES D3, D3D ILO OERED DIRECIONL CONROL VLVES ank and Drain Line Surges If several valves are piped with a common tank or drain line, flow surges in the line may cause an unexpected spool shift. Separate tank and drain lines should be piped in installations where line surges are expected. Loss of ilot ressure Should oil pilot pressure fail, spring offset and spring centered valves will shift to the spring held position. Detented valves will stay in the last position held before power failure. If main flow does not fail or stop at the same time power fails, machine actuators may continue to function in an undesirable manner or sequence. Series D31, D3* ilot Drain Characteristics ilot ressure: 6.9 to 345 ar (100 to 5000 SI) Direct pilot operated valves use the X and Y ports to supply pilot oil directly to the ends of the spool, providing spool shifting force. block mounted on top of the valve body is internally cored to make the necessary connections. hus when X is pressurized, Y is used as a drain; and when Y is pressurized, X becomes the drain. ny back pressure in these lines when they are being used as a drain is additive to the pilot pressure requirement. Internal Drain: On spring offset models, only the X port is pressurized, as the spring returns the spool to its at rest position. On these models, Y may be internally drained through the main tank passage in the valve. Mounting attern D3 valves may be mounted on a standard D05 pattern subplate or manifold only if the X and Y ports are externally connected to the pilot block on top of the main body. ll other mounting styles require a D05H or D05HE pattern which incorporates ports for the X and Y pilot and drain passages. Location of these ports can be found on the Recommended Mounting Surface pages in this section. D3 Flow ath/ilot ressure Style Code Recommended Description X & Y X ort Y ort Special Notes Control Valve De-ressurized ressurized ressurized For ilot Oil wo osition X ort may be pressurized to Spring Offset,,, assist spring in returning spool to offset position (ext. only) hree osition Flow paths will be reversed on C Spring Centered Center,, valves with tandem center (8) spools wo-osition Y ort may be pressurized H Spring Offset,,, to assist spring in returning spool to offset position D31.indd, dd 110 Elyria, Ohio, US

112 Installation Information Series D31, D3* Series D31VW, D31V, D31VL, D3 Subplate Mounting NF D05H, CEO 5 Recommended Mounting Surface Surface must be flat within.102 mm ( inch).i.r and smooth within micro-meters (32 micro-inch). orque bolts to 16.3 Nm (12 ft-lbs). Mounting osition Valve ype Detent (Solenoid) Spring Offset Spring Centered Mounting osition Horizontal Unrestricted Unrestricted For maximum valve reliability, adhere to the following installation information. Mounting attern NF D05H, CEO 5 Inch equivalents for millimeter dimensions are shown in (**) D31.indd, dd 111 Elyria, Ohio, US

113 Installation Information Series D31, D3* Series D31DW, D31D, D31DL, D3D, D31NW Subplate Mounting NF D05HE, CEO 5H Recommended Mounting Surface Surface must be flat within.102 mm ( inch).i.r. and smooth within micro-meters (32 micro-inch). orque bolts to 16.3 Nm (12 ft-lbs). Mounting osition Valve ype Detent (Solenoid) Spring Offset Spring Centered Mounting osition Horizontal Unrestricted Unrestricted For maximum valve reliability, adhere to the following installation information. Mounting attern NF D05HE, CEO 5H Inch equivalents for millimeter dimensions are shown in (**) 50.8 (2.00) 27.0 (1.06) 54.0 (2.13) 37.3 (1.47) 16.7 (.66) 61.9 (2.44) 91.9 (3.62) min. with X& Y ports 72.1 (2.84) min. without X& Y ports 21.4 (.84) 11.1 (.44) 11.1 (.44) 6.4 (.25) 7.9 (.31) 57.9 (2.28) min (1.81) 43.6 (1.72) 32.5 (1.28) X Y 6.3 (O.25) max. X&Yports.56 (.022) L 75.0 (2.95) 11.2 (O.44) max.... &ports.56 L (.022) M6x1 (1/4-20) UNC-2 thread x 9.7 (.38) min. thread depth 4 places.28 (.011) S D31.indd, dd 112 Elyria, Ohio, US

114 Catalog HY /US Introduction pplication Series D41 hydraulic directional control valves are high performance, solenoid controlled, pilot operated, 2-stage, 4-way valves. hey are available in 2 or 3 position styles and are manifold mounted. hese valves conform to NF s D07, CEO 7 mounting patterns. Operation Series D41 directional valves consist of a 5-chamber style main body, a case hardened sliding spool, and a pilot valve or oil pilot operator. Series D41VW Features Easy access mounting bolts. 345 ar (5000 SI) pressure rating. Flows to 300 LM (79.4 GM) depending on spool. Choice of three operator styles. Rugged four land spools. Low pressure drop. hosphate finish. D41VW Solenoid Operated lug-in Conduit ox D4L Lever Operated D41.indd, dd 114 Elyria, Ohio, US

115 echnical Information Series D41VW General Description Series D41VW valves are piloted by a D1VW valve. he valves can be ordered with position control. he minimum pilot pressure must be ensured for all operating conditions of the directional valve. dditionally spools with a to connection in the deenergized position need an external pressure supply (external inlet) or an integral check valve. Features World design vailable worldwide. Mounting bolts below center line of spool Minimizes spool binding. Five chamber style Eliminates pressure spikes in tubes, increasing valve life. High pressure and flow ratings Increased performance options in a compact valve. Dimensions Inch equivalents for millimeter dimensions are shown in (**) * lease add for each sandwich plate +40mm (1.58 ) (pressure reducing valve, pilot choke valve meter-in/-out). Surface Finish K320 4x M10x60 2x M6x55 DIN he space necessary to remove the plug per DIN 43650, design type F is at least 15 mm. he torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm. 63 Nm (46.5 lb.-ft.) 13.2 Nm (9.7 lb.-ft.) ±15% Seal Nitrile: SK-D41VW-N-91 Fluorocarbon: SK-D41VW-V-91 D41.indd, dd 115 Elyria, Ohio, US

116 Ordering Information Series D41VW D Directional Control Valve 41V asic Valve W ctuator Solenoid Wet in Spool Style ilot Supply and Drain NF D07, CEO 7 DIN NG16 3-osition Spools Code Spool ype a 0 b Code C Code Description 1 Internal ilot External Dain 2 External ilot External Drain 3 Internal ilot w/ Check Internal Drain 4 Internal ilot Internal Drain 5 External ilot Internal Drain 6 Internal ilot w/ Check Internal Drain * Not available with 002, 007, 009, 054 spools. 3-osition Spools ll 3-osition Spools 3 positions. Spring offset in position 0. Operated in position a or b. Standard Spool ype E Operated in position a. Operated in position b. 2 positions. Spring offset in position F Spring offset in position b. Spring offset in position a. 2 positions. Operated in position K Operated in position b. Operated in position a. 2 positions. Spring offset in position M Spring offset in position a. Spring offset in position b. 2 positions. Operated in position 0. Weight: Single Solenoid: Double Solenoid: osition Spools Code Spool ype a b kg (21.4 lbs.) 10.3 kg (22.7 lbs.) R S Code D H No center in offset position. No center in offset position. No center in offset position. No center in offset position. 2-osition Spools Spool osition 2 positions, detent. Operated in position 0 or b. 2 positions, detent. Operated in position 0 or a. No center in offset position. Spring offset in position b. Operated in position a. Detent, operated in position a or b. No center or offset position. Spring offset in position a. Operated in position b. D41.indd, dd old: Designates ier I products and options. Non-old: Designates ier II products and options. hese products will have longer lead times. 116 Elyria, Ohio, US

117 Ordering Information Series D41VW Seal N Nitrile V Fluorocarbon Solenoid Voltage Solenoid Connection Coil Options ube Options Manual Override Options Electrical Options Shift Response and Indication Valve Variations See next page Design Series NOE: Not required when ordering. * 24/50 VC D 120 VDC G 198 VDC J 24 VDC K 12 VDC N** 220/50 VC Q* 100/60 VC QD 100 VC/60 HZ 100 VC/50 HZ R 24/60 VC 240/60-220/50 VC U 98 VDC Y 120/60-110/50 VC Z 250 VDC * High Watt Coil only. ** Explosion roof only. vailable in DIN only. C* Leadwire Conduit ox D** Metric lug (M12X1), DESIN E Explosion roof G lug-in Conduit ox J# Deutsch (D06-2S) M# Metri-ack (150) DIN with lug S# Dual Spade W DIN w/o lug * No variations See lug-in. ** DC only, lights, diode surge suppressor, not CS approved. Not available with lights. Required for variations on conduit box style. Must have lights. # DC only, no lights, not CS approved. Code Omit Omit Standard Extended with oot None DC or C Rectified only. Manual Override options not available with Explosion roof. Description Standard ressure ar (1500 SI) C 207 ar (3000 SI) DC H* High ressure, C only 207 ar (3000 SI) * Not available with CS. Omit* High Watt D** Explosion roof, EEXD EX E** Explosion roof, EEXME EX F Low Watt L 10 Watt O** Explosion roof, MSH # Explosion roof, Ex d IIC EX/CS U ** Explosion roof, UL/CS * C ambient temperature must not exceed 60 C (140 F). ** 60 Hz only on C, no options. C only. DC and C rectified only. # J, K and Y voltages only. Dual frequency on C, no options. Code Omit I3N I6N Description Standard Response, No Switch Monitor Switch, & ort End Monitor Switch, & ort Start Note: Not CE or CS approved. Spools 005, 006, 008, 016, 054, 081 and 082 not available. C style only. Omit No Options J* Diode Surge Suppressor Z Rectified Coil * DC or C Rectified only. DIN coil must include plug with lights. DC tube standard. D41.indd, dd old: Designates ier I products and options. Non-old: Designates ier II products and options. hese products will have longer lead times. 117 Elyria, Ohio, US

118 Ordering Information Series D41VW Valve Variations 5* Signal Lights Standard Signal Lights Hirsch. (DIN with lug) 7** Manaplug rad Harrison (12x1) Micro with Lights 56** Manaplug (Mini) with Lights 1C** Manaplug (Mini) Single Sol. 5-pin, with Lights 1D** Manaplug (Micro) Single Sol. 5-pin, with Lights 1G** Manaplug (Mini) Single Sol. 5-pin, with Stroke djust & End and Lights 1H** Manaplug (Micro) Single Sol. 5-pin, with Stroke djust & End and Lights 1M** Manaplug Opposite Normal 1R Stroke djust & End with ilot Choke Meter In 3 ilot Choke Meter Out 3 ilot Choke Meter In 3C ilot ressure Reducer 3D Stroke djust End 3E Stroke djust End 3F Stroke djust & End 3G* ilot Choke Meter Out with Lights 3H* ilot Choke Meter In with Lights 3J* ilot ressure Reducer with Lights 3K ilot Choke Meter Out with Stroke djust & End 3L** ilot Choke Meter Out, Stroke djust & End with Lights and Manaplug rad Harrison Mini 3M ilot Choke Meter Out, ilot ressure Reducer, Stroke djust & End 3R ilot Choke Meter Out & ilot ressure Reducer 3S** Lights and 5-pin Mini Manaplug with ilot Choke 7Y** M12x1 Manaplug (4-pin), Special Wiring, and Lights * DESIN, plug-in conduit box, and DIN with plug styles only. ** Must have plug-in style conduit box. old: Designates ier I products and options. Non-bold: Designates ier II products and options. hese products will have longer lead times. D41.indd, dd 118 Elyria, Ohio, US

119 echnical Information Solenoid Ratings Insulation System llowable Deviation from rated voltage rmature CS File Number Environmental Capability Class F -15% to +10% for DC and C rectified coils -5% to +5% for C Coils Wet pin type LR60407 DC Solenoids meet NEM 4 and I67 when properly wired and installed. Contact HVD for C coil applications. Series D41VW Explosion roof Solenoid Ratings* U.L. & CS (EU) Class I, Div 1 & 2, Groups C & D Class II, Div 1 & 2, Groups E, F & G s defined by the N.E.C. MSH (EO) Complies with 30CFR, art 18 EX (ED) Complies with EX requirements for: Exd, Group II; EN50014: mds. 1 & 2, EN50018: 2000 EX & CS/US (E) Complies with EX EN , EN Ex d IIC; CS/US Ex d IIC, Ex d IIC for Class I, Zone 1, UL1203, UL1604, CS E61241,1 Class II, Div 1 * llowable Voltage Deviation ±10%. Note that Explosion roof C coils are single frequency only. Code Voltage In Rush mps In Rush Holding mps Watts Resistance Voltage ower mperage 3MM Code Code D L 120 VDC N/ N/ 0.09 mps 10 W ohms D Omit 120 VDC N/ N/ 0.26 mps 30 W ohms G Omit 198 VDC N/ N/ 0.15 mps 30 W ohms J L 24 VDC N/ N/ 0.44 mps 10 W ohms J Omit 24 VDC N/ N/ 1.32 mps 30 W ohms K L 12 VDC N/ N/ 0.88 mps 10 W ohms K Omit 12 VDC N/ N/ 2.64 mps 30 W 4.32 ohms L L 6 VDC N/ N/ 1.67 mps 10 W 3.59 ohms L Omit 6 VDC N/ N/ 5.00 mps 30 W 1.20 ohms Q Omit 100 VC / 60 Hz 2.05 mps 170 V 0.77 mps 30 W ohms QD F 100 VC / 60 Hz 1.35 mps 135 V 0.41 mps 18 W ohms QD F 100 VC / 50 Hz 1.50 mps 150 V 0.57 mps 24 W ohms R F 24/60 VC, Low Watt 6.67 mps 160 V 2.20 mps 23 W 1.52 ohms Omit 240/60 VC 0.83 mps 199 V 0.30 mps 30 W ohms Omit 220/50 VC 0.87 mps 191 V 0.34 mps 30 W ohms F 240/60 VC, Low Watt 0.70 mps 168 V 0.22 mps 21 W ohms F 220/50 VC, Low Watt 0.75 mps 165 V 0.26 mps 23 W ohms U L 98 VDC N/ N/ 0.10 mps 10 W ohms U Omit 98 VDC N/ N/ 0.31 mps 30W ohms Y Omit 120/60 VC 1.7 mps 204 V 0.60 mps 30 W ohms Y Omit 110/50 VC 1.7 mps 187 V 0.68 mps 30 W ohms Y F 120/60 VC, Low Watt 1.40 mps 168 V 0.42 mps 21 W ohms Y F 110/50 VC, Low Watt 1.50 mps 165 V 0.50 mps 23 W ohms Z L 250 VDC N/ N/ 0.04 mps 10 W ohms Z Omit 250 VDC N/ N/ 0.13 mps 30 W ohms Explosion roof Solenoids R 24/60 VC 7.63 mps 183 V 2.85 mps 27 W 1.99 ohms 240/60 VC 0.76 mps 183 V 0.29 mps 27 W 1.34 ohms N 220/50 VC 0.77 mps 169 V 0.31 mps 27 W 1.38 ohms Y 120/60 VC 1.60 mps 192 V 0.58 mps 27 W ohms 110/50 VC 1.47 mps 162 V 0.57 mps 27 W ohms K 12 VDC N/ N/ 2.75 mps 33 W 4.36 ohms J 24 VDC N/ N/ 1.38 mps 33 W ohms "E" Explosion roof Solenoids K 12 VDC N/ N/ 1.00 mps 12 W ohms J 24 VDC N/ N/ 1.00 mps 13 W ohms Y 120/60-50 VC N/ N/ 0.16 mps 17 W ohms D41.indd, dd 119 Elyria, Ohio, US

120 Specifications Series D41VW General Design Directional Spool Valve ctuation Solenoid Size NG16 Mounting Interface DIN / ISO 4401 / NF D07 / CEO R 121-H Mounting osition Unrestricted, preferably horizontal mbient emperature [ C] [ C] ; (-13 F F) (without inductive position control) ; (+32 F F) (with inductive position control) MF D Value [years] 75 Hydraulic ilot drain internal:,,, X 350 ar (5075 SI);, Y 105 ar (1523 SI) Maximum Operating ressure ilot drain external:,,,, X 350 ar (5075 SI); Y 105 ar (1523 SI) 10 Watt 207 ar (3000 SI) Fluid Hydraulic oil in accordance with DIN / Fluid emperature [ C] (-13 F F) Viscosity ermitted [cst]/[mm²/s] ( SSU) Recommended [cst]/[mm²/s] ( SSU) Filtration ISO 4406 (1999); 18/16/13 (meet NS 1638: 7) Flow Maximum 300 LM (79.4 GM) Leakage at 350 ar (per flow path) [ml/min] up to 200 (0.05 GM) (depending on spool) Operating ressure Integral Check Valve See p/q Diagram Minimum ilot Supply ressure 5 ar (73 SI) Static / Dynamic Step Response at 85% Energized De-energized DC Solenoids ilot ressure 50 ar [ms] ar [ms] ar & 350 ar [ms] C Solenoids ilot ressure 50 ar [ms] ar [ms] ar & 350 ar [ms] D41.indd, dd 120 Elyria, Ohio, US

121 Electrical Specifications Series D41VW osition Control M12x1 rotection Class I 65 in accordance with EN (plugged and mounted) mbient emperature [ C] ; (+32 F F) Supply Voltage / Ripple [V] ±10% Current Consumption without Load [m] 30 Max. Output Current per Channel, Ohmic [m] 400 Min. Output Load per Channel, Ohmic [kohm] 100 Max. Output Drop at 0.2 [V] 1.1 Max. Output Drop at 0.4 [V] 1.6 EMC EN / EN Max. olerance mbient Field Strength [/m] <1200 Min. Distance to Next C Solenoid [m] >0.1 Interface M12x1 per IEC Wiring Minimum [mm²] 5 x 0.25 brad shield recommended Wiring Length Maximum [m] 50 (164 ft.) recommended M12 in ssignment 1 + Supply V 2 Out : normally closed 3 0V 4 Out : normally open 5 Earth ground Definitions Start position monitored: he valve is de-energized. he inductive switch gives a signal at the moment (below 15% spool stroke) when the spool leaves the spring offset position. End position monitored: he inductive switch gives a signal before the end position is reached. (above 85% spool stroke). Delivery includes plug M12 x 1 (order no.: ). D41.indd, dd 121 Elyria, Ohio, US

122 echnical Information Series D41VW erformance Curves he flow curve diagram shows the flow versus pressure drop curves for all spool types. he relevant curve number for each spool type, operating position and flow direction is given in the table below. ll characteristic curves measured with HL46 at 50 C. Spool Curve Number Code Integral Check Valve in the port Mounting an integral check valve in the port is necessary to build up pilot pressure for valves with to connection and internal pilot oil supply. he pressure difference at the integral check valve (see performance curves) is to be added to all flow curves of the -port of the main valve. ilot Oil Inlet (Supply) and Outlet (Drain) D41.indd, dd ll orifice sizes for standard valves 122 Elyria, Ohio, US

123 ccessories Manaplug (Options 6, 56, 1 & 1C) Interface rad Harrison lug 3-in for Single Solenoid 5-in for Double Solenoid Ground Wire #1 (Green) Series D41VW Micro Connector Options (7, 7, 1 & 1D) Solenoid (Negative) Wire #3 (Red/lack) Solenoid (ositive) Wire #2 (Red/White) 3-in Manaplug (Mini) with Lights Single Solenoid Valves Installed Opposite Side of Solenoid ins are as seen on valve (male pin connectors) Manaplug Electrical Mini lug E E E in lug 5 in lug (Double Solenoid) 5 in lug (Single Solenoid) Conduit ox Option C No Wiring Options vailable Manaplug Electrical Micro lug E E E in lug 5 in lug (Double Solenoid) 5 in lug (Single Solenoid) Signal Lights (Option 5) lug-in Only LED Interface Meets Nema 4/I67 Hirschmann lug with Lights (Option 5) ISO 4400/DIN Form D41.indd, dd in #2 (ositive) Face View of lug in #3 (Ground) in #1 (Negative) DESIN Connector (Option D) M12 pin assignment Standard 1 = Not used 2 = Not used 3 = 0V 4 = Signal (24 V) 5 = Earth Ground ins are as seen on valve (male pin connectors) DESIN design in 1 and 2 connected Elyria, Ohio, US

124 echnical Information Series D4L General Description Series D4L valves are 5 chamber, directional control valves and are available in 2 or 3-position styles. hey are operated by a hand lever which is directly connected to the spool. he hand lever can be located either on the or side. Spring offset and detent designs are available. Features Low force required to shift spool. Hardened spools provide long life. Low pressure drop design. Specifications General Design Directional spool valve ctuation Lever Size NG16 Mounting interface DIN , ISO 4401, NF D07, CEO R 121-H Mounting osition Unrestricted, preferably horizontal mbient emperature [ C] ; (-13 F F) Hydraulic Maximum Operating ressure External Drain:,, 350 ar (5075 SI); X, Y 10 ar (145 SI) Internal Drain:, 350 ar (5075 SI);, X, Y 10 ar (145 SI) Fluid Hydraulic oil in accordance with DIN / Fluid emperature [ C] ; (-13 F F) Viscosity ermitted [cst] /[mm²/s] ( SSU) Recommended [cst] /[mm²/s] ( SSU) Filtration ISO 4406 (1999); 18/16/13 (meet NS 1638: 7) Maximum Flow 300 LM (79.4 GM) Leakage at 350 ar (per flow path) [ml/min] up to 200 (0.05 GM) (depending on spool) D41.indd, dd 124 Elyria, Ohio, US

125 Ordering Information Series D4L D Directional Control Valve 4 asic Valve NF D07, CEO 7 DIN NG16 ctuator Spool Style ilot Supply and Drain Code N V Seal Description Nitrile Fluorocarbon Design Series NOE: Not required when ordering. Code L L ctuation Lever Side Lever Side 3 osition Spools Code Spool ype a 0 b 1 Code C Code Description 2* External ilot External Drain 5** External ilot Internal Drain * ressure -port > 10 bar ** ressure -port < 10 bar 3 osition Spools ll 3 osition Spools 3 positions. Spring offset in position 0. Operated in position a or b. Standard Spool ype E Operated in position a. Operated in position b. 2 positions. Spring offset in position F Operated in position 0. Operated in position 0. 2 positions. Spring offset in position b K Operated in position b. Operated in position a. 2 positions. Spring offset in position 0. 2 osition Spools Code Spool ype a b M N Operated in position 0. No center in offset position. Operated in position 0. No center in offset position. 2 positions. Spring offset in position a. 3 positions, detent. Operated in position a, 0 or b. R No center in offset position. No center in offset position. 2 positions, detent. Operated in position 0 or b. Weight: 9.0 kg (19.8 lbs.) S No center in offset position. No center in offset position. 2 positions, detent. Operated in position 0 or a. No center in offset position. Further spool types on request. D41.indd, dd Code D H 2 osition Spools Spool osition Spring offset in position b. Operated in position a. Detent, operated in position a or b. No center or offset position. Spring offset in position a. Operated in position b. 125 Elyria, Ohio, US

126 erformance Curves Series D4L he flow curve diagram shows the flow versus pressure drop curves for all spool types. he relevant curve number for each spool type, operating position and flow direction is given in the table below. Spool Code Curve Number ll characteristic curves measured with HL46 at 50 C. D41.indd, dd 126 Elyria, Ohio, US

127 Dimensions Series D4L Inch equivalents for millimeter dimensions are shown in (**) D4L D4L Surface Finish Seal K320 4x M10x60 2x M6x55 DIN Nm (46.5 lb.-ft.) 13.2 Nm (9.7 lb.-ft.) ±15% Nitrile: SK-D4LN60 Fluorocarbon: SK-D4LV60 D41.indd, dd 127 Elyria, Ohio, US

128 echnical Information Series D4 General Description Series D4 directional control valves are 5-chamber pilot operated valves. hey are available in 2 or 3-position styles. hese manifod mounted valves conform to NF s D07, CEO 7 and NG16. Features Low pressure drop design. Hardened spools for long life. Specifications General Design Directional spool valve ctuation Hydraulic Size NG16 Mounting interface DIN , ISO 4401, NF D07, CEO R 121-H Mounting osition Unrestricted, preferably horizontal mbient emperature [ C] (-13 F F) MF D value 150 years Hydraulic Maximum Operating ressure External Drain:,, 350 ar (5075 SI); X, Y 350 ar (5075 SI) Fluid Hydraulic oil in accordance with DIN / Fluid emperature [ C] (-13 F F) Viscosity ermitted [cst] /[mm²/s] ( SSU) Recommended [cst] /[mm²/s] ( SSU) Filtration ISO 4406 (1999); 18/16/13 (meet NS 1638: 7) Maximum Flow 300 LM (79.4 GM) Leakage at 350 ar (per flow path) [ml/min] up to 200 (0.05 GM) (depending on spool) ilot Supply ressure Static / Dynamic Step Response Minimum Maximum 5 ar (73 SI) 350 ar (5075 SI) he response times depend on the pilot oil pressure and on the speed of the increase/ decrease of the pilot pressure. D41.indd, dd 128 Elyria, Ohio, US

129 Ordering Information Series D4 D Directional Control Valve 4 asic Valve NF D07, CEO 7 DIN NG16 3 osition Spools Code Spool ype a 0 b Hydraulically Operated Spool Style Code C ilot Supply and Drain External ilot / External Drain Code N V Seal Description Nitrile Fluorocarbon Omit Standard Valve Valve Variations ilot Choke, Meter-Out Stroke adjust End 3 osition Spools ll 3 osition Spools 3 positions. Spring offset in position 0. Operated in position a or b. Standard Spool ype Design Series NOE: Not required when ordering. Stroke djust End ilot Choke, Meter-In Stroke djust and Ends E Operated in position a. Operated in position b. 2 positions. Spring offset in position F Spring offset in position b. Spring offset in position a. 2 positions. Operated in position K Operated in position b. Operated in position a. 2 positions. Spring offset in position M Spring offset in position a. Spring offset in position b. 2 positions. Operated in position osition Spools Code Spool ype a b R S No center in offset position. No center in offset position. No center in offset position. No center in offset position. 2 positions, detent. Operated in position 0 or b. 2 positions, detent. Operated in position 0 or a. No center in offset position. 30 Code 2 osition Spools Spool osition Spring offset in position b. Operated in position a. Weight: 9.0 kg (19.8 lbs.) D Detent, operated in position a or b. No center or offset position. D41.indd, dd H Spring offset in position a. Operated in position b. Further spool types and position control on request. 129 Elyria, Ohio, US

130 erformance Curves Series D4 he flow curve diagram shows the flow versus pressure drop curves for all spool types. he relevant curve number for each spool type, operating position and flow direction is given in the table below. Spool Curve Number Code D41.indd, dd 130 Elyria, Ohio, US

131 Dimensions Series D4 Inch equivalents for millimeter dimensions are shown in (**) Surface Finish Seal K320 4x M10x60 2x M6x55 DIN Nm (46.5 lb.-ft.) 13.2 Nm (9.7 lb.-ft.) ±15% Nitrile: SK-D41VW-N-91 Fluorocarbon: SK-D41VW-V-91 D41.indd, dd 131 Elyria, Ohio, US

132 Catalog HY /US Installation Information FOR MXIMUM VLVE RELIILIY, DHERE O HE FOLLOWING INSLLION INFORMION. he following is important installation information which applies to all directional control valves described in this catalog. Mounting osition Detent Horizontal Spring Offset Unrestricted Spring Centered Unrestricted Fluid Recommendations remium quality hydraulic oil with a viscosity range between cst. ( SSU) t 38 C (100 F) is recommended. he absolute operating viscosity range is from cst. ( SSU). Oil should have maximum anti-wear properties and rust and oxidation treatment. Fluids and Seals Valves using synthetic, fire-resistant fluids require special seals. When phosphate esters or its blends are used, FLUOROCRON seals are required. Waterglycol, water-in-oil emulsions and petroleum oil may be used with SNDRD seals. Filtration For maximum valve and system component life, the system should be protected from contamination at a level not to exceed 125 particles greater than 10 microns per milliliter of fluid (SE class 4/ISO 16/13). Series D41 Silting Silting can cause any sliding spool valve to stick and not spring return if held under pressure for long periods of time. he valve should be cycled periodically to prevent sticking. Special Installations Consult your arker representative for any application requiring the following: ressure above rating. Fluid other than those specified. Oil temperature above 71.1 C (160 F). Flow path other than normal. Mounting atterns Series NF CEO D41V D07 7 orque Specifications he recommended torque values for the bolts which mount the valve to the manifold or subplate are as follows: 63 Nm (46.5 ft-lbs) M Nm (9.7 ft-lbs) M6 1/4-20. D41.indd, dd 132 Elyria, Ohio, US

133 Installation Information Series D41 ank and Drain Line Surges If several valves are piped with a common tank or drain line, flow surges in the line may cause an unexpected spool shift. Detent style valves are most susceptible to this. Separate tank and drain lines should be piped in installations where line surges are expected. Electrical Characteristics (Detented Spool) Only a momentary energizing of the solenoid is necessary to shift and hold a detented spool. Minimum duration of the signal is 0.1 seconds for DC voltages. For C voltages the response time is 0.06 seconds. Spool position will be held provided the spool centerline is in a horizontal plane, and not shock or vibration is present to displace the spool. Electrical Failure or Loss of ilot ressure Should electric power fail or loss of pilot pressure occur, spring offset and spring centered valves will shift to the spring held position. Detented valves will stay in the last position held before power failure. If main flow does not fail or stop at the same time power fails, machine actuators may continue to function in an undesirable manner or sequence. ilot/drain Characteristics ilot ressure: 5 to 345 ar (73 to 5000 SI) 6.9 ar (100 SI) for spools 002, 007, 009 & 014 External: n oil source sufficient to maintain minimum pilot pressure must be connected to the X port of the main body. When using the external pilot variation, a 1/16 pipe plug must be present in the main body pilot passage. (For details see echnical pages.) his plug will be furnished in valves ordered with pilot code 2, 3, 5 or 6. D41V* Flow aths Internal: Flow is internally ported from the pressure port of the main valve body to the port of the pilot valve. he pressure developed at the port of the pilot valve must be 5.0 ar (73 SI) minimum at all times or 6.9 ar (100 SI) for spools 002, 007, 009 & 014. Integral Check: Valves using internal pilot and internal drain with an open center spool (spools 2, 7 & 9) can be ordered with an integral check valve in the pressure port of the main valve codes 3 & 6. ilot oil will be internally ported from the upstream side of this check to the port of the pilot valve, ensuring sufficient pilot pressure. 1/16 pipe plug will be present in the main body. he X port in the subplate must be plugged when using the integral check. ilot Valve Drain: Maximum pressure 102 ar (1500 SI) C optional, 207 ar (3000 SI) DC standard. External: When using an external drain, a M6 x 1 x 6mm long set screw must be present in the main body drain passage. (For details see echnical pages.) his plug will be furnished in valves ordered with drain code 1, 2 or 3. Drain flow from the pilot valve is at the Y port of the main body and must be piped directly to tank. Maximum drain line pressure is 102 ar (1500 SI), C optional, 207 ar (3000 SI) DC standard. ny drain line back pressure is additive to the pilot pressure requirement. Internal: Drain flow from the pilot valve is internally connected to the main valve tank port. ank and drain pressure are then identical so tank line pressure should not exceed 102 ar (1500 SI), C optional, 207 ar (3000 SI) DC standard. ny tank line back pressure is also additive to the pilot pressure requirement. If flow surges (a cause of pressure surges) are anticipated in the tank line, an external drain variation is recommended. he Y port in the subplate must be plugged when using an internal drain. Style No Solenoid/Operator Solenoid/Operator Solenoid/Operator Energized Energized Energized Spring Offset and and C Spring Centered Centered and and D Detented Last osition Held and and E Spring Centered Centered and F Spring Offset, Shift to Center and Centered H Spring Offset and and K Spring Centered Centered and M Spring Offset, Shift to Center and Centered D41.indd, dd 133 Elyria, Ohio, US

134 Installation Information Series D4 ank and Drain Line Surges If several valves are piped with a common tank or drain line, flow surges in the line may cause an unexpected spool shift. Detent style valves are most susceptible to this. Separate tank and drain lines should be piped in installations where line surges are expected. Loss of ilot ressure Should a loss of pilot pressure occur, spring offset and spring centered valves will shift to the spring held position. No spring valves will stay in the last position held. If main hydraulic flow does simultaneously stop, machine actuators may continue to function in an undesirable manner or sequence. ilot Drain Characteristics ilot ressure: 5 to 350 ar (73 to 5000 SI) 6.9 ar (100 SI) for spool configurations 2, 7, 9 & 14 Direct pilot operated valves use the X and Y ports to supply pilot oil directly to the ends of the spool, providing spool shifting force. block mounted on top of the valve body is internally cored to make the necessary connections. hus when X is pressurized, Y is used as a drain; and when Y is pressurized, X becomes the drain. ny back pressure in these lines when they are being used as a drain is additive to the pilot pressure requirement. Internal Drain: On spring offset models, only the X port is pressurized, as the spring returns the spool to its at rest position. On these models, Y may be internally drained through the main tank passage in the valve. Flow ath/ilot ressure Style Code Recommended Description X & Y X ort Y ort Special Notes Control Valve De-ressurized ressurized ressurized For ilot Oil wo osition X ort may be pressurized to Spring Offset,,, assist spring in returning spool to offset position (ext. only) hree osition Flow paths will be reversed on C Spring Centered Center,, valves with tandem center (9) spool wo-osition Y ort may be pressurized H Spring Offset,,, to assist spring in returning spool to offset position D41.indd, dd 134 Elyria, Ohio, US

135 Installation Information Series D41VW, D4, D4L Subplate Mounting NF D07, CEO 7 & NG16 Recommended Mounting Surface Surface must be flat within.102 mm ( inch).i.r and smooth within micro-meters (32 micro-inch). orque bolts to Nm (100 ft-lbs). Mounting osition Valve ype Detent (Solenoid) Spring Offset Spring Centered Mounting osition Horizontal Unrestricted Unrestricted For maximum valve reliability, adhere to the following installation information. Mounting attern NF D07, CEO 7 & NG16 Inch equivalents for millimeter dimensions are shown in (**) Note: With * marked dimensions ±0.1 mm. ll other dimensions ±0.2mm. D41.indd, dd 135 Elyria, Ohio, US

136 Catalog HY /US Introduction pplication Series D6 hydraulic directional control valves are high performance, solenoid controlled, pilot operated, 2-stage, 4-way valves. hey are available in 2 or 3-position styles. hese valves are manifold mounted, and conform to NF s D08, CEO 8 mounting patterns. Operation Series D61 directional valves consist of a 5-chamber style main body, a case hardened sliding spool, and a pilot valve or pilot operators (hydraulic or pneumatic). Series D61 Features Easy access mounting bolts. 210 ar (3000 SI) pressure rating. Flows to 380 LM (100 GM) depending on spool. Choice of four operator styles. Rugged four land spools. Low pressure drop. hosphate finish. D61*W Solenoid Operated lug-in Conduit ox D61*L Lever Operated D6* Oil ilot Operated D61* ir ilot Operated D61.indd, dd 136 Elyria, Ohio, US

137 echnical Information Series D61V General Description Series D61VW directional control valves are 5-chamber, pilot operated, solenoid controlled valves, hey are available in 2 or 3-position styles. hese valves are manifold or subplate mounted, and conform to NF s D08, CEO 8 mounting patterns. Operation Series D61VW pilot operated valves are standard with low shock spools and pilot orifice. he orifice can be removed if a faster shift is required. It is recommended, however, that all systems operating above 138 ar (2000 SI) use the standard valve to avoid severe shock. Features Low pressure drop design. Hardened spools provide long life. Fast response option available. Explosion proof availability. Wide variety of voltages and electrical connection options. No tools required for coil removal. Specifications Mounting attern Maximum Operating ressure Maximum ank Line ressure Maximum Drain ressure Minimum ilot ressure Maximum ilot ressure Nominal Flow Maximum Flow NF D08 CEO 8, NG ar (3000 SI) Standard CS 205 ar (3000 SI) Internal Drain Model: 102 ar (1500 SI) C Only 205 ar (3000 SI) DC Std./ C Optional External Drain Model: 205 ar (3000 SI) CS 102 ar (1500 SI) 102 ar (1500 SI) C Standard 205 ar (3000 SI) DC Standard/ C Optional CS 102 ar (1500 SI) 5.1 ar* (75 SI) 205 ar (3000 SI) Standard CS 205 ar (3000 SI) 189 LM (50 GM) See Reference Data Chart * 6.9 ar (100 SI) for spool configurations 002, 007, 008, 009 & 014. Response ime Response times (milliseconds) are measured at 205 ar (3000 SI) and 195 LM (50 GM) with various pilot pressures as indicated. Solenoid ilot ull-in Drop-Out ype ressure Std Fast Std Fast DC C ecause of the high drain line pressure transients generated during shifting, use of the fast response option is not recommended for pilot pressures exceeding 138 ar (2000 SI). D61.indd, dd 137 Elyria, Ohio, US

138 Ordering Information Series D61V D Directional Control Valve 61V asic Valve ctuator Spool Style ilot Supply Seal Solenoid and Drain Voltage Code 001 NF D08, CEO 8, DIN NG25 Low Flow, D03 ilot W* Solenoid, Wet in, Screw-in HW* Reversed Wiring * Valve schematic symbols are per NF/NSI standards, providing flow to when energizing solenoid. Note operators reverse sides for #008 and #009 spools. See installation information for details. o configure per DIN standards ( coil over port, coil over port) code valves as D61VHW***. Symbol Code 011 Symbol Code N V Description Nitrile Fluorocarbon 1 Internal ilot, External Drain 2 External ilot, External Drain 3** Internal ilot w/check, External Drain 4* Internal ilot, Internal Drain 5 External ilot, Internal Drain 6** Internal ilot w/check Internal Drain * Not availble with 002, 007, 008, 009 & 014 spools. ** #3 and #6 bodies cannot be converted to other styles. Other pilot versions cannot be converted to styles 3 and 6. Symbol * 24/50 VC D 120 VDC G 198 VDC J 24 VDC K 12 VDC N** 220/50 VC Q* 100/60 VC QD 100 VC/60 HZ 100 VC/50 HZ R 24/60 VC 240/60-220/50 VC U 98 VDC Y 120/60-110/50 VC Z 250 VDC * High Watt only. ** Explosion roof only. vailable in DIN only * Single solenoid, 2 position, spring offset. to and to in offset position. C Double solenoid, 3 position, spring centered. b b a D* Double solenoid, 2 position, detent. b a * 009** * 008 spool has closed crossover. ** 009 spool has open crossover. E F** Single solenoid, 2 position, spring centered. to and to when energized. Single solenoid, 2 position, spring offset, energized to center. osition spool spacer on side. to and to in spring offset position. H* Single solenoid, 2 position, spring offset. to and to in offset position. K Single solenoid, 2 position, spring centered. to and to when energized. M** Single solenoid, 2 position, spring offset, energized to center position. Spool spacer on side. to and to in spring offset position. * vailable with 001, 002, 004, 011 and 014 spools only. ** High watt coil only. b b a a a D61.indd, dd old: Designates ier I products and options. Non-bold: Designates ier II products and options. hese products will have longer lead times. 138 Elyria, Ohio, US

139 Ordering Information Series D61V Solenoid Connection C* Leadwire Conduit ox D** Metric lug (M12X1), DESIN E Explosion roof G lug-in Conduit ox J# Deutsch (D06-2S) M# Metri-ack (150) DIN with lug S# Dual Spade W DIN w/o lug * No variations See lug-in. ** DC only, lights, diode surge suppressor, not CS approved. Not available with lights. Required for variations on conduit box style. Must have lights. # DC only, no lights, not CS approved. Coil Options Code Omit ube Options Manual Override Options Omit Standard Extended with oot None DC or C Rectified only. Manual Override options not available with Explosion roof. Description Standard ressure ar (1500 SI) C 207 ar (3000 SI) DC H* High ressure, C only 207 ar (3000 SI) * Not available with CS. Electrical Options Shift Response and Indication pprovals Valve Variations See next page Design Series NOE: Not required when ordering. Omit Standard Valve 3* CS US 4*# CS pproved * Not available with C high pressure tube. # Valve is derated with this option., C, H styles only. J, K, Y, U voltages only with C, G, W solenoid connections only. Conforms to UL429. Omit* High Watt D** Explosion roof, EEXD EX E** Explosion roof, EEXME EX F Low Watt L 10 Watt O** Explosion roof, MSH # Explosion roof, Ex d IIC EX/CS U** Explosion roof, UL/CS * C ambient temperature must not exceed 60 C (140 F). ** 60 Hz only on C, no options. C only. DC and C rectified only. # J, K and Y voltages only. Dual frequency on C, no options. Valve Weight: Double Solenoid Seal Kit: Nitrile Fluorocarbon 12.1 kg (26.6 lbs.) SKD61VWN91 SKD61VWV91 Omit No Options J* Diode Surge Suppressor Z Rectified Coil * DC only. DIN coil must include plug with lights. DC tube standard. Code Omit I3 I6 Note: Mounting olt Kits Description Standard Response, No Switch Monitor Switch, & ort End Monitor Switch, & ort Start Not CE or CS approved. Not available with F or M styles. UNC olt Kits for use with D6 and D8 & Sandwich Valves Number of Sandwich 2.75 (70mm) thickness D6 K227 K121 K122 K D6 plus K161 K170 K171 K172 tapping plate D8 K228 K131 K132 K D8 plus K173 K174 K175 K114 tapping plate D61.indd, dd old: Designates ier I products and options. Note: ll bolts are SE grade 8, 1/2-13 UNC-3 thread, torque to 133 N.m. (100 ft.-lbs.) Non-bold: Designates ier II products and options. hese products will have longer lead times. 139 Elyria, Ohio, US

140 Ordering Information Series D61V Valve Variations 5* Signal Lights Standard Signal Lights Hirsch. (DIN with plug) 7** Manaplug rad Harrison (12x1) Micro with lights 56** Manaplug (Mini) with Lights 20 Fast Response 1C** Manaplug (Mini) Single Sol. 5-pin, with Lights 1D** Manaplug (Micro) Single Sol. 5-pin, with Lights 1G** Manaplug (Mini) Single Sol. 5-pin, with Stroke djust & End and Lights 1H** Manaplug (Micro) Single Sol. 5-pin, with Stroke djust & End and Lights 1M** Manaplug Opposite Normal 1 ainted ody 1R Stroke djust & End with ilot Choke Meter In 3 ilot Choke Meter Out 3 ilot Choke Meter In 3C ilot ressure Reducer 3D Stroke djust End 3E Stroke djust End 3F Stroke djust & End 3G* ilot Choke Meter Out with Lights 3H* ilot Choke Meter In with Lights 3J* ilot ressure Reducer with Lights 3K ilot Choke Meter Out with Stroke djust & End 3L** ilot Choke Meter Out, Stroke djust & End with Lights and Manaplug rad Harrison Mini 3M ilot Choke Meter Out, ilot ressure Reducer, Stroke djust & End 3R ilot Choke Meter Out & ilot ressure Reducer 3S** Lights, Mini Manaplug, ilot Choke Meter Out 7Y** M12x1 Manaplug (4-pin), Special Wiring, and Lights * DESIN, plug-in conduit box, and DIN with plug styles only. ** Must have plug-in style conduit box. D61.indd, dd 140 Elyria, Ohio, US

141 echnical Information Series D61V Reference Data MaximumFlow, Maximum Flow, LM (GM) LM (GM) Spool 207 ar (3000 SI) Spool 207 ar (3000 SI) Model Symbol w/o Malfunction Model Symbol w/o Malfunction D61V* (100) D61V* (80) D61V* (80) D61V* (80) D61V* (100) D61V* (100) D61V* (100) D61V* (35) D61V* (100) D61V* (50) D61V* (100) D61V* (100) D61V* (50) D61V* (100) D61V* Series ressure Drop Chart he following chart provides the flow vs. pressure drop curve reference for the Series D61V valves by spool type. VISCOSIY CORRECION FCOR Viscosity (SSU) % of (pprox.) Curves were generated using 100 SSU hydraulic oil. For any other viscosity, pressure drop will change as per chart. erformance Curves D61VW ressure Drop Reference Chart -- Curve Number Spool No / D61.indd, dd 141 Elyria, Ohio, US

142 Catalog HY /US echnical Information Solenoid Ratings Insulation System llowable Deviation from rated voltage rmature CS File Number Environmental Capability Class F -15% to +10% for DC and C rectified coils -5% to +5% for C Coils Wet pin type LR60407 DC Solenoids meet NEM 4 and I67 when properly wired and installed. Contact HVD for C coil applications. Series D61V Explosion roof Solenoid Ratings* U.L. & CS (EU) Class I, Div 1 & 2, Groups C & D Class II, Div 1 & 2, Groups E, F & G s defined by the N.E.C. MSH (EO) Complies with 30CFR, art 18 EX (ED) Complies with EX requirements for: Exd, Group II; EN50014: mds. 1 & 2, EN50018: 2000 EX & CS/US (E) Complies with EX EN , EN Ex d IIC; CS/US Ex d IIC, Ex d IIC for Class I, Zone 1, UL1203, UL1604, CS E61241,1 Class II, Div 1 * llowable Voltage Deviation ±10%. Note that Explosion roof C coils are single frequency only. Code Voltage In Rush mps In Rush Holding mps Watts Resistance Voltage ower mperage 3MM Code Code D L 120 VDC N/ N/ 0.09 mps 10 W ohms D Omit 120 VDC N/ N/ 0.26 mps 30 W ohms G Omit 198 VDC N/ N/ 0.15 mps 30 W ohms J L 24 VDC N/ N/ 0.44 mps 10 W ohms J Omit 24 VDC N/ N/ 1.32 mps 30 W ohms K L 12 VDC N/ N/ 0.88 mps 10 W ohms K Omit 12 VDC N/ N/ 2.64 mps 30 W 4.32 ohms L L 6 VDC N/ N/ 1.67 mps 10 W 3.59 ohms L Omit 6 VDC N/ N/ 5.00 mps 30 W 1.20 ohms Q Omit 100 VC / 60 Hz 2.05 mps 170 V 0.77 mps 30 W ohms QD F 100 VC / 60 Hz 1.35 mps 135 V 0.41 mps 18 W ohms QD F 100 VC / 50 Hz 1.50 mps 150 V 0.57 mps 24 W ohms R F 24/60 VC, Low Watt 6.67 mps 160 V 2.20 mps 23 W 1.52 ohms Omit 240/60 VC 0.83 mps 199 V 0.30 mps 30 W ohms Omit 220/50 VC 0.87 mps 191 V 0.34 mps 30 W ohms F 240/60 VC, Low Watt 0.70 mps 168 V 0.22 mps 21 W ohms F 220/50 VC, Low Watt 0.75 mps 165 V 0.26 mps 23 W ohms U L 98 VDC N/ N/ 0.10 mps 10 W ohms U Omit 98 VDC N/ N/ 0.31 mps 30W ohms Y Omit 120/60 VC 1.7 mps 204 V 0.60 mps 30 W ohms Y Omit 110/50 VC 1.7 mps 187 V 0.68 mps 30 W ohms Y F 120/60 VC, Low Watt 1.40 mps 168 V 0.42 mps 21 W ohms Y F 110/50 VC, Low Watt 1.50 mps 165 V 0.50 mps 23 W ohms Z L 250 VDC N/ N/ 0.04 mps 10 W ohms Z Omit 250 VDC N/ N/ 0.13 mps 30 W ohms Explosion roof Solenoids R 24/60 VC 7.63 mps 183 V 2.85 mps 27 W 1.99 ohms 240/60 VC 0.76 mps 183 V 0.29 mps 27 W 1.34 ohms N 220/50 VC 0.77 mps 169 V 0.31 mps 27 W 1.38 ohms Y 120/60 VC 1.60 mps 192 V 0.58 mps 27 W ohms 110/50 VC 1.47 mps 162 V 0.57 mps 27 W ohms K 12 VDC N/ N/ 2.75 mps 33 W 4.36 ohms J 24 VDC N/ N/ 1.38 mps 33 W ohms "E" Explosion roof Solenoids K 12 VDC N/ N/ 1.00 mps 12 W ohms J 24 VDC N/ N/ 1.00 mps 13 W ohms Y 120/60-50 VC N/ N/ 0.16 mps 17 W ohms D61.indd, dd 142 Elyria, Ohio, US

143 Dimensions Series D61V Inch equivalents for millimeter dimensions are shown in (**) lug-in Conduit ox, Double C Solenoid Note: 41.9mm (1.65") from bottom of bolt hole counterbore to bottom of valve. D61.indd, dd 143 Elyria, Ohio, US

144 Dimensions Series D61V Inch equivalents for millimeter dimensions are shown in (**) lug-in Conduit ox and Stroke djust, Double C Solenoid Note: 41.9mm (1.65") from bottom of bolt hole counterbore to bottom of valve. lug-in Conduit ox, Single C Solenoid Note: 41.9mm (1.65") from bottom of bolt hole counterbore to bottom of valve. D61.indd, dd 144 Elyria, Ohio, US

145 Dimensions Series D61V Inch equivalents for millimeter dimensions are shown in (**) lug-in Conduit ox, Double DC Solenoid Note: 41.9mm (1.65") from bottom of bolt hole counterbore to bottom of valve. D61.indd, dd 145 Elyria, Ohio, US

146 Dimensions Series D61V Inch equivalents for millimeter dimensions are shown in (**) lug-in Conduit ox and Stroke djust, Double DC Solenoid Note: 41.9mm (1.65") from bottom of bolt hole counterbore to bottom of valve. Hirschmann and ilot Choke Control, Double DC Solenoid lug-in Conduit ox, Single DC Solenoid D61.indd, dd 146 Elyria, Ohio, US

147 Dimensions Series D61V Inch equivalents for millimeter dimensions are shown in (**) lug-in Conduit ox, Double DC Solenoid with Variation I3 (Monitor Switch) Monitor Switch (Variation I3 and I6) his feature provides for electrical confirmation of the spool shift. his can be used in safety circuits, to assure proper sequencing, etc. Switch Data in 1 and in 3 have outputs equal to the input. When the monitor switch has the output to in 1, in 3 will have an output of zero, and vice-versa. When the valve is switched, in 1 and in 3 will switch outputs. IN 2 Input VDC osition Control Switch Sensor / Driver Circuitry Load 0.2 Max IN 1 IN 3 Outputs D61.indd, dd 147 Elyria, Ohio, US

148 Catalog HY /US ccessories Manaplug (Options 6, 56, 1 & 1C) Interface rad Harrison lug 3-in for Single Solenoid 5-in for Double Solenoid Ground Wire #1 (Green) Series D61V Micro Connector Options (7, 7, 1 & 1D) Solenoid (Negative) Wire #3 (Red/lack) Solenoid (ositive) Wire #2 (Red/White) 3-in Manaplug (Mini) with Lights Single Solenoid Valves Installed Opposite Side of Solenoid ins are as seen on valve (male pin connectors) Manaplug Electrical Mini lug E E E in lug 5 in lug (Double Solenoid) 5 in lug (Single Solenoid) Conduit ox Option C No Wiring Options vailable Manaplug Electrical Micro lug E E E in lug 5 in lug (Double Solenoid) 5 in lug (Single Solenoid) Signal Lights (Option 5) lug-in Only LED Interface Meets Nema 4/I67 Hirschmann lug with Lights (Option 5) ISO 4400/DIN Form D61.indd, dd in #2 (ositive) Face View of lug in #3 (Ground) in #1 (Negative) DESIN Connector (Option D) M12 pin assignment Standard 1 = Not used 2 = Not used 3 = 0V 4 = Signal (24 V) 5 = Earth Ground ins are as seen on valve (male pin connectors) DESIN design in 1 and 2 connected Elyria, Ohio, US

149 echnical Information Series D61V General Description Series D61V directional control valves are 5-chamber, air pilot operated valves. hey are available in 2 or 3-position styles. hese valves are manifold or subplate mounted, and conform to NF s D08, CEO 8 mounting patterns. Specifications Mounting attern Max. Operating ressure Max. ank ressure Max. Drain ressure Maximum Flow ilot ressure Response ime Ordering Information D Directional Control Valve D61.indd, dd NF D08 CEO 8 Code Symbol Code Symbol * 009** V asic Valve * 008 spool has closed crossover. ** 009 spool has open crossover. NF D08, CEO 8, NG ar (3000 SI) ir Operated ilot Valve schematic symbols are per NF/ NSI standards, providing flow to when energizing operator. Note operators reverse sides for #8 and #9 spools. See installation information for details. Internal Drain Model: 34 ar (500 SI) External Drain Model: 207 ar (3000 SI) 34 ar (500 SI) See Reference Data ir Min. 3.4 ar (50 SI) ir Max ar (150 SI) Varies with pilot line size and length, pilot pressure, pilot valve shift time & flow capacity (GM) Features Spool Style ilot Supply Seal and Drain Low pressure drop. Fast response option available. Hardened spools provide long life. Valve Variations N Nitrile Omit Standard V Fluorocarbon 7 ilot Choke Meter-out 8 Stroke dj. End 1 Int. pilot/ext. drain 9 Stroke dj. End 2 Ext. pilot/ext. drain 60 ilot Choke Meter-in 4# Int. pilot/int. drain 89 Stroke dj. & Ends 5 Ext. pilot/int. drain 90 1/4 Shreads # Not available with 002, 008 & 009 spools. Symbol b Single operator, 2 position, spring offset. to and to in offset position. C D Double operator, 3 position, spring centered. Double operator, 2 position, detent. b b b a Design Series NOE: Not required when ordering. E Single operator, 2 position, spring offset to center. Valve Weight: 12.4 kg (27.3 lbs.) to and to in shifted position. a Standard olt Kit: K227 H Single operator, 2 position, spring offset. Metric olt Kit: KM227 to and to in offset position. Seal Kit: a K Single operator, 2 position. Spring offset to center. Nitrile SKD61V to and to in shifted position. Fluorocarbon SKD61VV old: Designates ier I products and options. Non-old: Designates ier II products and options. hese products will have longer lead times. a his condition varies with spool code. 149 Elyria, Ohio, US

150 Dimensions Series D61V Inch equivalents for millimeter dimensions are shown in (**) Note: 41.9mm (1.65") from bottom of bolt hole counterbore to bottom of valve. D61.indd, dd 150 Elyria, Ohio, US

151 echnical Information Series D61VL General Description Series D61VL directional control valves are 5-chamber, lever operated valves. hey are available in 2 and 3-position styles. hey are manifold or subplate mounted valves, which conform to NF s D08, CEO 8 mounting patterns. Specifications Mounting attern NF D08, CEO 8, NG25 Max. Operating 207 ar (3000 SI) ressure Max. ank Internal Drain Model: ressure 34 ar (500 SI) External Drain Model: 207 ar (3000 SI) Maximum Drain 34 ar (500 SI) ressure Maximum Flow See Reference Data ilot Oil Min. 6.9 ar (100 SI) ressure Oil Max. 207 ar (3000 SI) Varies with pilot line size and Response ime length, pilot pressure, pilot valve shift time & flow capacity (GM) Ordering Information D Directional Control Valve NF D08 CEO 8 Code Symbol Code Symbol * 009** V asic Valve * 008 spool has closed crossover. ** 009 spool has open crossover. Valve schematic symbols are per NF/ NSI standards, providing flow to when energizing operator. Note operators reverse sides for #8 and #9 spools. See installation information for details. L Lever Operated ilot Features Spool Style ilot Supply Seal and Drain Low force required to shift spool. Hardened spools provide long life. Low pressure drop design. 1 Int. pilot/ext. drain N Nitrile 2 Ext. pilot/ext. drain V Fluorocarbon 4# Int. pilot/int. drain 5 Ext. pilot/int. drain # Not available with 002, 008 & 009 spools. * Single operator, 2 position, spring offset. to and to in offset position. C Double operator, 3 position, spring centered. D* Double operator, 2 position, detent. E Single operator, 2 position, spring centered. to and to in shifted position. H* Single operator, 2 position, spring offset. to and to in offset position. K Single operator, 2 position. Spring centered. to and to in shifted position. Symbol Valve Weight: 12.1 kg (26.7 lbs.) Standard olt Kit: K227 Metric olt Kit: KM227 Seal Kit: Nitrile SKD61VL * vailable with 001, 002, 004, 011, 012. Fluorocarbon SKD61VLV old: Designates ier I products and options. Non-old: Designates ier II products and options. hese products will have longer lead times. D61.indd, dd Valve Variations Omit Standard 7 ilot Choke Meter Out 8 Stroke dj. End 9 Stroke dj. End 60 ilot Choke Meter In 89 Stroke dj. & Ends Design Series NOE: Not required when ordering. his condition varies with spool code. 151 Elyria, Ohio, US

152 Dimensions Series D61VL Inch equivalents for millimeter dimensions are shown in (**) Note: 41.9mm (1.65") from bottom of bolt counterbore. D61.indd, dd 152 Elyria, Ohio, US

153 echnical Information Series D6 General Description Series D6 directional control valves are 5-chamber, pilot operated valves. hey are available in 2 or 3-position styles. hese valves are manifold or subplate mounted, and conform to NF s D08, CEO 8 mounting patterns. Features Low pressure drop design. Hardened spools provide long life. Fast response option available. Specifications Mounting attern NF D08, CEO 8, NG25 Max. Operating ress. 207 ar (3000 SI) Max. ank Line ress. 207 ar (3000 SI) Max. Drain ressure 207 ar (3000 SI) Min. ilot ressure 5.1 ar* (75 SI) Max. ilot ressure 207 ar (3000 SI) Nominal Flow 189 Liters/Min (50 GM) Maximum Flow See Reference Chart * 6.9 ar (100 SI) for 2, 8, 9 & 12 spools For flow path, pilot drain and pilot pressure details, see Installation Information. Ordering Information Response ime Response time will vary with pilot line size, pilot line length, pilot pressure shift time and flow capacity of the control valve. Shift Volume he pilot chamber requires a volune of 0.54 in 3 for center to end and 1.08 in 3 for end to end. D 6 Directional Control Valve Code Symbol Code Symbol * 8 spool has closed crossover. ** 9 spool has open crossover. Valve schematic symbols are per NF/NSI standards, providing flow to when energizing operator X. Note operators reverse sides for #8 and #9 spools. See installation information for details. D61.indd, dd 1 8* 9** asic Valve NF D08 CEO 8 Hydraulic ilot Valve Weight: 11.0 kg (24.2 lbs.) Standard olt Kit: K227 Metric olt Kit: KM227 Spool Style ilot Supply Seal and Drain Code N V ype Nitrile Fluorocarbon 2 Ext. ilot Ext. Drain 5# Ext. ilot Int. Drain # vailable in & H styles only. Symbol C H Single operator, 2 position, spring offset. to and to in offset position. Double operator, 3 position, spring centered. Single operator, 2 position, spring offset. to and to in offset position. Valve Variations Design Series NOE: Not required when ordering. Omit Standard 7 ilot Choke Meter Out 8 Stroke dj. End 9 Stroke dj. End 20 Fast Response 60 ilot Choke Meter In 89 Stroke dj. & Ends old: Designates ier I products and options. Non-old: Designates ier II products and options. hese products will have longer lead times. his condition varies with spool code. 153 Elyria, Ohio, US

154 Dimensions Series D6 Inch equivalents for millimeter dimensions are shown in (**) Standard ilot Operated ilot Operated with ilot Choke Control Note: 41.9mm (1.65") from bottom of bolt hole counterbore to bottom of valve. ilot Choke Control Variation (1.56) (7.23) Note: 41.9mm (1.65") from bottom of bolt hole counterbore to bottom of valve. D61.indd, dd 154 Elyria, Ohio, US

155 Installation Information FOR MXIMUM VLVE RELIILIY, DHERE O HE FOLLOWING INSLLION INFORMION. he following is important installation information which applies to all directional control valves described in this catalog. Mounting osition Detent Horizontal Spring Offset Unrestricted Spring Centered Unrestricted Fluid Recommendations remium quality hydraulic oil with a viscosity range between cst. ( SSU ) t 38 C (100 F) is recommended. he absolute operating viscosity range is from cst. ( SSU). Oil should have maximum anti-wear properties and rust and oxidation treatment. Fluids and Seals Valves using synthetic, fire-resistant fluids require special seals. When phosphate esters or its blends are used, FLUOROCRON seals are required. Waterglycol, water-in-oil emulsions and petroleum oil may be used with SNDRD seals. Series D61V, D6 Silting Silting can cause any sliding spool valve to stick and not spring return if held under pressure for long periods of time. he valve should be cycled periodically to prevent sticking. Special Installations Consult your arker representative for any application requiring the following: ressure above rating. Fluid other than those specified. Oil temperature above 71.1 C (160 F). Flow path other than normal. Mounting atterns Series NF Size D61V*, D6 D08, CEO 8 3/4 orque Specifications he recommended torque values for the bolts which mount the valve to the manifold or subplate are as follows: Nm (100 ft-lbs). Filtration For maximum valve and system component life, the system should be protected from contamination at a level not to exceed 125 particles greater than 10 microns per milliliter of fluid (SE class 4/ISO 16/13). D61.indd, dd 155 Elyria, Ohio, US

156 Installation Information Series D61V Series D61VW, D61V, D61VL ank and Drain Line Surges If several valves are piped with a common tank or drain line, flow surges in the line may cause an unexpected spool shift. Detent style valves are most susceptible to this. Separate tank and drain lines should be piped in installations where line surges are expected. Electrical Characteristics (Detented Spool) Only a momentary energizing of the solenoid is necessary to shift and hold a detented spool. Minimum duration of the signal is 0.1 seconds for DC voltages. For C voltages the response time is 0.06 seconds. Spool position will be held provided the spool centerline is in a horizontal plane, and not shock or vibration is present to displace the spool. Electrical Failure or Loss of ilot ressure (D61V) Should electric power fail or loss of pilot pressure occur, spring offset and spring centered valves will shift to the spring held position. Detented valves will stay in the last position held before power failure. If main flow does not fail or stop at the same time power fails, machine actuators may continue to function in an undesirable manner or sequence. ilot/drain Characteristics ilot ressure: 5.1 to 207 ar (75 to 3000 SI) 6.9 ar (100 SI) for spools 002, 007, 008, 009 & 014 External: n oil source sufficient to maintain minimum pilot pressure must be connected to the X port of the main body. When using the external pilot variation, a 1/16" pipe plug must be present in the main body pilot passage. (For details see Dimension pages.) his plug will be furnished in valves ordered with pilot code 2, 3, 5 or 6. Internal: Flow is internally ported from the pressure port of the main valve body to the port of the pilot valve. he pressure developed at the port of the pilot valve must be 5.1 ar (75 SI) minimum at all times or 6.9 ar (100 SI) for spools 002, 007, 008, 009 & 014. Integral Check: Valves using internal pilot and internal drain with an open center spool (spools 002, 008 & 009) can be ordered with an integral check valve in the pressure port of the main valve codes 3 & 6. ilot oil will be internally ported from the upstream side of this check to the port of the pilot valve, ensuring sufficient pilot pressure. 1/16 pipe plug will be present in the main body. he X port in the subplate must be plugged when using the integral check. ilot Valve Drain: Maximum pressure 102 ar (1500 SI), 207 ar (3000 SI) optional. External: When using an external drain, a 10 x 24 x 0.31 long set screw must be present in the main body drain passage. (For details see Dimension pages.) his plug will be furnished in valves ordered with drain code 1, 2 or 3. Drain flow from the pilot valve is at the Y port of the main body and must be piped directly to tank. Maximum drain line pressure is 102 ar (1500 SI), 207 ar (3000 SI) optional. ny drain line back pressure is additive to the pilot pressure requirement. Internal: Drain flow from the pilot valve is internally connected to the main valve tank port. ank and drain pressure are then identical so tank line pressure should not exceed 102 ar (1500 SI), 207 ar (3000 SI) optional. ny tank line back pressure is also additive to the pilot pressure requirement. If flow surges (a cause of pressure surges) are anticipated in the tank line, an external drain variation is recommended. he Y port in the subplate must be plugged when using an internal drain. D61V* Flow aths Style No Solenoid/Operator Solenoid/Operator Solenoid/Operator Energized Energized Energized Spring Offset and and C Spring Centered Centered and and D Detented Last osition Held and and E Spring Centered Centered and F Spring Offset, Shift to Center and Centered H Spring Offset and and K Spring Centered Centered and M Spring Offset, Shift to Center and Centered D61VW only. D61.indd, dd 156 Elyria, Ohio, US

157 Installation Information Series D6 Series D6 ank and Drain Line Surges If several valves are piped with a common tank or drain line, flow surges in the line may cause an unexpected spool shift. Detent style valves are most susceptible to this. Separate tank and drain lines should be piped in installations where line surges are expected. Loss of ilot ressure Should a loss of pilot pressure occur, spring offset and spring centered valves will shift to the spring held position. No spring valves will stay in the last position held. If main hydraulic flow does simultaneously stop, machine actuators may continue to function in an undesirable manner or sequence. ilot Drain Characteristics ilot ressure: 5.1 to 207 ar (75 to 3000 SI) 6.9 ar (100 SI) for spools 2, 8, 9 & 12 Direct pilot operated valves use the X and Y ports to supply pilot oil directly to the ends of the spool, providing spool shifting force. block mounted on top of the valve body is internally cored to make the necessary connections. hus when X is pressurized, Y is used as a drain; and when Y is pressurized, X becomes the drain. ny back pressure in these lines when they are being used as a drain is additive to the pilot pressure requirement. Internal Drain: On spring offset models, only the X port is pressurized, as the spring returns the spool to its at rest position. On these models, Y may be internally drained through the main tank passage in the valve. Flow ath/ilot ressure Style Code Recommended Description X & Y X ort Y ort Special Notes Control Valve De-ressurized ressurized ressurized For ilot Oil wo osition X ort may be pressurized to Spring Offset,,, assist spring in returning spool to offset position (ext. only) hree osition Flow paths will be reversed on C Spring Centered Center,, valves with tandem center (8) spools wo-osition Y ort may be pressurized H Spring Offset,,, to assist spring in returning spool to offset position D61.indd, dd 157 Elyria, Ohio, US

158 Catalog HY /US Installation Information Subplate Mounting NF D08, CEO 8 & NG 25 Recommended Mounting Surface Surface must be flat within.102 mm ( inch).i.r and smooth within micro-meters (32 micro-inch). orque bolts to Nm (100 ft-lbs). Mounting osition Valve ype Detent (Solenoid) Spring Offset Spring Centered Mounting osition Horizontal Unrestricted Unrestricted Series D61V, D6 For maximum valve reliability, adhere to the following installation information. Mounting attern NF D08, CEO 8 & NG 25 Inch equivalents for millimeter dimensions are shown in (**) (6.00) (5.13) (3.97) (4.44) 94.5 (3.72) (0.69) 4.8 (0.19) 77.0 (3.03) 29.4 (1.16) 53.2 (2.09) 17.5 (0.69) ½ 13 UNC 2x22.22 min th'd dp. (M12 x0.875) 6 holes 0.28 S (0.011) (5.12) 92.1 (3.63) (2.94) 73.0 (2.88) O11.2 (0.441) max. 3 holes 0.56 L (0.022) O (0.922) max. 4 holes 0.56 L (0.022) O /.272 x0.31 min dp. (7.32 / 6.91 x 8) 2 holes 0.28 L (0.011) D61.indd, dd 158 Elyria, Ohio, US

159 Catalog HY /US Introduction pplication Series D81 hydraulic directional control valves are high performance, solenoid controlled, pilot operated, 2-stage, 4-way valves. hey are available in 2 or 3-position styles and are manifold mounted. hese valves conform to NF s D08, CEO 8 mounting pattern. Operation Series D81 directional valves consist of a 5-chamber style main body, a case hardened sliding spool, and a pilot valve or pilot operators (hydraulic or pneumatic). Series D81 Features Easy access mounting bolts. 345 ar (5000 SI) pressure rating. Flows to 622 LM (160 GM) depending on spool. Choice of four operator styles. Rugged four land spools. Low pressure drop. hosphate finish. D81VW Solenoid Operated lug-in Conduit ox D81VL Lever Operated D8 Oil ilot Operated D81V ir ilot Operated D81.indd, dd 160 Elyria, Ohio, US

160 echnical Information Series D81V General Description Series D81VW directional control valves are 5-chamber, pilot operated, solenoid controlled valves. hey are available in 2 or 3-position styles. hese valves are manifold or subplate mounted, and conform to NF s D08, CEO 8 mounting pattern. Operation Series D81VW pilot operated valves are standard with low shock spools and pilot orifice. he orifice can be removed if a faster shift is required. It is recommended, however, that all systems operating above 138 ar (2000 SI) use the standard valve to avoid severe shock. Features Low pressure drop design. Hardened spools provide long life. Fast response option available. Wide variety of voltages and electrical connection options. Explosion proof availability. No tools required for coil removal. Response Specifications Mounting attern NF D08, CEO 8, NG25 Maximum Operating 345 ar (5000 SI) Standard ressure 207 ar (3000 SI) 10 Watt Maximum ank Line ressure CS 207 ar (3000 SI) Internal Drain Model: 103 ar (1500 SI) C Only 207 ar (3000 SI) DC Std., C Optional External Drain Model: 345 ar (5000 SI) CS 103 ar (1500 SI) Maximum Drain 103 ar (1500 SI) C Only ressure 207 ar (3000 SI) DC Std., C Optional CS 103 ar (1500 SI) Minimum ilot 5.1 ar* (75 SI) ressure Maximum ilot 345 ar (5000 SI) Standard ressure CS 207 ar (3000 SI) Nominal Flow 302 LM (80 GM) * 6.9 ar (100 SI) for spool configurations 002, 007, 008, 009 & 014. ime Response times (milliseconds) are measured at 345 ar (5000 SI) and 300 LM (80 GM) with various pilot pressures as indicated. Solenoid ilot ull-in Drop-Out ype ressure Std Fast Std Fast DC C ecause of the high drain line pressure transients generated during shifting, use of the fast response option is not recommended for pilot pressures exceeding 138 ar (2000 SI). D81.indd, dd 161 Elyria, Ohio, US

161 Ordering Information Series D81V D Directional Control Valve Code * 009** V asic Valve ctuator Spool Style ilot Supply Seal Solenoid and Drain Voltage NF D08 CEO 8 DIN NG25 High Flow, D03 ilot W* Solenoid, Wet in, Screw-in HW* Reversed Wiring * Valve schematic symbols are per NF/ NSI standards, providing flow to when energizing solenoid. Note operators reverse sides for #008 and #009 spools. See installation information for details. o configure per DIN standards ( coil over port, coil over port) code valves as D81VHW***. Symbol Code * 030** * 008 & 020 spool have closed crossover. ** 009 & 030 spool have open crossover. Symbol Code N V Description Nitrile Fluorocarbon * 24/50 VC D 120 VDC G 198 VDC J 24 VDC K 12 VDC N** 220/50 VC Q* 100/60 VC QD 100 VC/60 Hz 100 VC/50 Hz R 24/60 VC 240/60-220/50 VC U 98 VDC Y 120/60-110/50 VC Z 250 VDC * High Watt Coil only. ** Explosion roof only. vailable in DIN only. Symbol * Single solenoid, 2 position, spring offset. to and to in offset position. C Double solenoid, 3 position, spring centered. D* Double solenoid, 2 position, detent. E F** Single solenoid, 2 position, spring centered. to and to when energized. Single solenoid, 2 position, spring offset, energized to center. osition spool spacer on side. to and to in spring offset position. H* Single solenoid, 2 position, spring offset. to and to in offset position. K M** 1 Internal ilot, External Drain 2 External ilot, External Drain 3 Internal ilot w/check, External Drain 4* Internal ilot, Internal Drain 5 External ilot, Internal Drain 6 Internal ilot w/check, Internal Drain * Not availble with 002, 007, 008, 009, 014 & 030 spools. Single solenoid, 2 position, spring centered. to and to when energized. Single solenoid, 2 position, spring offset, energized to center position. Spool spacer on side. to and to in spring offset position. * vailable with 020 and 030 spools only. ** High watt coil only. b b b b b a a a a a D81.indd, dd old: Designates ier I products and options. Non-bold: Designates ier II products and options. hese products will have longer lead times. 162 Elyria, Ohio, US

162 Ordering Information Series D81V Solenoid Connection C* Leadwire Conduit ox D** Metric lug (M12X1), DESIN E Explosion roof G lug-in Conduit ox J# Deutsch (D06-2S) M# Metri-ack (150) DIN with lug S# Dual Spade W DIN w/o lug * No variations See lug-in. ** DC only, lights, diode surge suppressor, not CS approved. Not available with lights. Required for variations on conduit box style. Must have lights. # DC only, no lights, not CS approved. Coil Options Omit* High Watt D** Explosion roof, EEXD EX E** Explosion roof, EEXME EX F Low Watt L 10 Watt O** Explosion roof, MSH # Explosion roof, Ex d IIC EX/CS U** Explosion roof, UL/CS * C ambient temperature must not exceed 60 C (140 F). ** 60 Hz only on C, no options. C only. DC and C rectified only. # J, K and Y voltages only. Dual frequency on C, no options. ube Options Code Omit Manual Override Options Electrical Options Code Omit I3 I6 Note: Omit No Options J* Diode Surge Suppressor Z Rectified Coil * DC only. DIN coil must include plug with lights. DC tube standard. Omit Standard Extended with oot None DC or C Rectified only. Manual Override options not available with Explosion roof. Description Standard ressure 103 ar (1500 SI) C 207 ar (3000 SI) DC H* High ressure, C only 207 ar (3000 SI) * Not available with CS. Shift Response and Indication Description Standard Response, No Switch Monitor Switch, & ort End Monitor Switch, & ort Start Not CE or CS approved. Not available with F or M styles. Valve Weight: Double Solenoid Seal Kit: Nitrile Fluorocarbon pprovals Mounting olt Kits Valve Variations See next page Omit Standard Valve 3* CS US 4*# CS pproved * Not available with C high pressure tube. # Valve is derated with this option., C, H styles only. J, K, Y, U voltages only with C, G, W solenoid connections only. Conforms to UL kg (43.2 lbs.) SKD81VWN91 SKD81VWV91 Design Series NOE: Not required when ordering. UNC olt Kits for use with D6 and D8 & Sandwich Valves Number of Sandwich 2.75 (70mm) thickness D6 K227 K121 K122 K D6 plus K161 K170 K171 K172 tapping plate D8 K228 K131 K132 K D8 plus K173 K174 K175 K114 tapping plate Note: ll bolts are SE grade 8, 1/2-13 UNC-3 thread, torque to 133 N.m. (100 ft.-lbs.) D81.indd, dd old: Designates ier I products and options. Non-bold: Designates ier II products and options. hese products will have longer lead times. 163 Elyria, Ohio, US

163 Ordering Information Series D81V Valve Variations 5* Signal Lights Standard Signal Lights Hirsch. (DIN with lug) 7** Manaplug rad Harrison (12x1) Micro with Lights 56** Manaplug (Mini) with Lights 20 Fast Response 1C** Manaplug (Mini) Single Sol. 5-pin, with Lights 1D** Manaplug (Micro) Single Sol. 5-pin, with Lights 1G** Manaplug (Mini) Single Sol. 5-pin, with Stroke djust & End and Lights 1H** Manaplug (Micro) Single Sol. 5-pin, with Stroke djust & End and Lights 1M** Manaplug Opposite Normal 1 ainted ody 1R Stroke djust & End with ilot Choke Meter In 3 ilot Choke Meter Out 3 ilot Choke Meter In 3C ilot ressure Reducer 3D Stroke djust End 3E Stroke djust End 3F Stroke djust & End 3G* ilot Choke Meter Out with Lights 3H* ilot Choke Meter In with Lights 3J* ilot ressure Reducer with Lights 3K ilot Choke Meter Out with Stroke djust & End 3L** ilot Choke Meter Out, Stroke djust & End with Lights and Manaplug rad Harrison Mini 3M ilot Choke Meter Out, ilot ressure Reducer, Stroke djust & End 3R ilot Choke Meter Out & ilot ressure Reducer 3S** Lights, Mini Manaplug, ilot Choke Meter Out 7Y** M12x1 Manaplug (4-pin), Special Wiring, and Lights * DESIN, plug-in conduit box, and DIN with plug styles only. ** Must have plug-in style conduit box. D81.indd, dd 164 Elyria, Ohio, US

164 echnical Information Series D81V Reference Data MaximumFlow, Maximum Flow, LM (GM) LM (GM) Spool 345 ar (5000 SI) Spool 345 ar (5000 SI) Model Symbol w/o Malfunction Model Symbol w/o Malfunction D81V* (160) D81V*008 D81V* (80) D81V* (160) D81V* (160) D81V* (160) D81V* (80) D81V* (160) D81V* (80) D81V* (160) D81V* (160) D81V* (160) D81V* (160) D81V* (80) D81V*020 D81V* (160) D81V* Series ressure Drop Chart he following chart provides the flow vs. pressure drop curve reference for the Series D81V* valve by spool type. VISCOSIY CORRECION FCOR Viscosity (SSU) % of (pprox.) Curves were generated using 100 SSU hydraulic oil. For any other viscosity, pressure drop will change as per chart. erformance Curves D81VW ressure Drop Reference Chart Curve Number Spool No / D81.indd, dd 165 Elyria, Ohio, US

165 Catalog HY /US echnical Information Solenoid Ratings Insulation System llowable Deviation from rated voltage rmature CS File Number Environmental Capability Class F -15% to +10% for DC and C rectified coils -5% to +5% for C Coils Wet pin type LR60407 DC Solenoids meet NEM 4 and I67 when properly wired and installed. Contact HVD for C coil applications. Series D81V Explosion roof Solenoid Ratings* U.L. & CS (EU) Class I, Div 1 & 2, Groups C & D Class II, Div 1 & 2, Groups E, F & G s defined by the N.E.C. MSH (EO) Complies with 30CFR, art 18 EX (ED) Complies with EX requirements for: Exd, Group II; EN50014: mds. 1 & 2, EN50018: 2000 EX & CS/US (E) Complies with EX EN , EN Ex d IIC; CS/US Ex d IIC, Ex d IIC for Class I, Zone 1, UL1203, UL1604, CS E61241,1 Class II, Div 1 * llowable Voltage Deviation ±10%. Note that Explosion roof C coils are single frequency only. Code Voltage In Rush mps In Rush Holding mps Watts Resistance Voltage ower mperage 3MM Code Code D L 120 VDC N/ N/ 0.09 mps 10 W ohms D Omit 120 VDC N/ N/ 0.26 mps 30 W ohms G Omit 198 VDC N/ N/ 0.15 mps 30 W ohms J L 24 VDC N/ N/ 0.44 mps 10 W ohms J Omit 24 VDC N/ N/ 1.32 mps 30 W ohms K L 12 VDC N/ N/ 0.88 mps 10 W ohms K Omit 12 VDC N/ N/ 2.64 mps 30 W 4.32 ohms L L 6 VDC N/ N/ 1.67 mps 10 W 3.59 ohms L Omit 6 VDC N/ N/ 5.00 mps 30 W 1.20 ohms Q Omit 100 VC / 60 Hz 2.05 mps 170 V 0.77 mps 30 W ohms QD F 100 VC / 60 Hz 1.35 mps 135 V 0.41 mps 18 W ohms QD F 100 VC / 50 Hz 1.50 mps 150 V 0.57 mps 24 W ohms R F 24/60 VC, Low Watt 6.67 mps 160 V 2.20 mps 23 W 1.52 ohms Omit 240/60 VC 0.83 mps 199 V 0.30 mps 30 W ohms Omit 220/50 VC 0.87 mps 191 V 0.34 mps 30 W ohms F 240/60 VC, Low Watt 0.70 mps 168 V 0.22 mps 21 W ohms F 220/50 VC, Low Watt 0.75 mps 165 V 0.26 mps 23 W ohms U L 98 VDC N/ N/ 0.10 mps 10 W ohms U Omit 98 VDC N/ N/ 0.31 mps 30W ohms Y Omit 120/60 VC 1.7 mps 204 V 0.60 mps 30 W ohms Y Omit 110/50 VC 1.7 mps 187 V 0.68 mps 30 W ohms Y F 120/60 VC, Low Watt 1.40 mps 168 V 0.42 mps 21 W ohms Y F 110/50 VC, Low Watt 1.50 mps 165 V 0.50 mps 23 W ohms Z L 250 VDC N/ N/ 0.04 mps 10 W ohms Z Omit 250 VDC N/ N/ 0.13 mps 30 W ohms Explosion roof Solenoids R 24/60 VC 7.63 mps 183 V 2.85 mps 27 W 1.99 ohms 240/60 VC 0.76 mps 183 V 0.29 mps 27 W 1.34 ohms N 220/50 VC 0.77 mps 169 V 0.31 mps 27 W 1.38 ohms Y 120/60 VC 1.60 mps 192 V 0.58 mps 27 W ohms 110/50 VC 1.47 mps 162 V 0.57 mps 27 W ohms K 12 VDC N/ N/ 2.75 mps 33 W 4.36 ohms J 24 VDC N/ N/ 1.38 mps 33 W ohms "E" Explosion roof Solenoids K 12 VDC N/ N/ 1.00 mps 12 W ohms J 24 VDC N/ N/ 1.00 mps 13 W ohms Y 120/60-50 VC N/ N/ 0.16 mps 17 W ohms D81.indd, dd 166 Elyria, Ohio, US

166 Dimensions Series D81V Inch equivalents for millimeter dimensions are shown in (**) lug-in Conduit ox, Double C Solenoid 1/16 lug forvariations 2 & 5 orque to: ±1.67 Nm (105 ±15 in-lbs) Do Not Loctite M6 x 1 lug forvariations 1, 2 & 3 orque to: 1.78 ±0.22 Nm (16 ±2 in-lbs) Do Not Loctite Note: 57mm (2.24") from bottom of bolt hole counterbore to bottom of valve. D81.indd, dd 167 Elyria, Ohio, US

167 Dimensions Series D81V Inch equivalents for millimeter dimensions are shown in (**) Conduit ox and Stroke djust, Double C Solenoid Note: 57mm (2.24") from bottom of bolt hole counterbore to bottom of valve. Conduit ox and ilot Choke Control, Double C Solenoid Conduit ox, Single C Solenoid D81.indd, dd 168 Elyria, Ohio, US

168 Dimensions Series D81V Inch equivalents for millimeter dimensions are shown in (**) lug-in Conduit ox, Double DC Solenoid Note: 57mm (2.24") from bottom of bolt hole counterbore to bottom of valve. D81.indd, dd 169 Elyria, Ohio, US

169 Dimensions Series D81V Inch equivalents for millimeter dimensions are shown in (**) lug-in Conduit ox and Stroke djust, Double DC Solenoid Note: 57mm (2.24") from bottom of bolt hole counterbore to bottom of valve. Hirschmann and ilot Choke Control, Double DC Solenoid lug-in Conduit ox, Single DC Solenoid D81.indd, dd 170 Elyria, Ohio, US

170 Dimensions Series D81V Inch equivalents for millimeter dimensions are shown in (**) lug-in Conduit ox, Double C Solenoid with Variation I3 (Monitor Switch) Monitor Switch (Variation I3 and I6) his feature provides for electrical confirmation of the spool shift. his can be used in safety circuits, to assure proper sequencing, etc. Switch Data in 1 and in 3 have outputs equal to the input. When the monitor switch has the output to in 1, in 3 will have an output of zero, and vice-versa. When the valve is switched, in 1 and in 3 will switch outputs. IN 2 Input VDC osition Control Switch Sensor / Driver Circuitry Load 0.2 Max IN 1 IN 3 Outputs D81.indd, dd 171 Elyria, Ohio, US

171 Catalog HY /US ccessories Manaplug (Options 56 & 1C) Interface rad Harrison lug 3-in for Single Solenoid 5-in for Double Solenoid Ground Wire #1 (Green) Series D81V Micro Connector Options (7 & 1D) Solenoid (Negative) Wire #3 (Red/lack) Solenoid (ositive) Wire #2 (Red/White) 3-in Manaplug (Mini) with Lights Single Solenoid Valves Installed Opposite Side of Solenoid ins are as seen on valve (male pin connectors) Conduit ox Option C No Wiring Options vailable Signal Lights (Option 5) lug-in Only LED Interface Meets Nema 4/I67 Hirschmann lug with Lights (Option 5) ISO 4400/DIN Form D81.indd, dd in #2 (ositive) Face View of lug in #3 (Ground) in #1 (Negative) DESIN Connector (Option D) M12 pin assignment Standard 1 = Not used 2 = Not used 3 = 0V 4 = Signal (24 V) 5 = Earth Ground ins are as seen on valve (male pin connectors) DESIN design in 1 and 2 connected Elyria, Ohio, US

172 echnical Information Series D81V General Description Series D81V directional control valves are 5-chamber, air pilot operated valves. hey are available in 2 or 3-position styles. hese valves are manifold or subplate mounted, and conform to NF s D08, CEO 8 mounting pattern. Specifications Mounting attern Max. Operating ressure Max. ank Line ressure Max. Drain ressure Maximum Flow ilot ressure Response ime Ordering Information D Directional Control Valve D81.indd, dd NF D08 CEO 8 DIN NG25 Code Symbol Code Symbol * 009** 030** 81V asic Valve * 020 spool has closed crossover. ** 009 & 030 spools have open crossover. NF D08, CEO 8, NG ar (5000 SI) Internal Drain Model: 34 ar (500 SI) External Drain Model: 207 ar (3000 SI) 34 ar (500 SI) See Switching Limit Charts ir Min 3.4 ar (50 SI) ir Max 10.2 ar (150 SI) Varies with pilot line size and length, pilot pressure, pilot valve shift time & flow capacity (GM) Valve schematic symbols are per NF/NSI standards, providing flow to when energizing operator. Note operators reverse sides for #9 spool. See installation information for details. Valve Weight: Single Operated 19.9 kg (43.9 lbs.) Standard olt Kit: K228 Metric olt Kit: KM228 ir Operated ilot Features Low pressure drop design. Fast response option available. Hardened spools provide long life. Spool Style ilot Supply Seal Valve and Drain Variations N Nitrile V Fluorocarbon 1 Int. pilot/ext. drain 2 Ext. pilot/ext. drain 4# Int. pilot/int. drain 5 Ext. pilot/int. drain # Not available with 002, 008, 009 & 030 spools. Symbol Sgl. operator, 2 position, spring offset. to and to in offset position. C Dbl. operator, 3 position, spring centered. D Dbl. operator, 2 position, detent. E Sgl. operator, 2 position, spring centered. to and to when energized. H Sgl. operator, 2 position, spring offset. to and to in offset position. K Sgl. operator, 2 position. Spring centered. to and to when energized. vailable with 020 & 030 spools only. Omit Standard 7 ilot Choke Meter Out 8 Stroke dj. End 9 Stroke dj. End 60 ilot Choke Meter In 89 Stroke dj. & Ends 90 1/4 Shreads b b b b a a a Design Series NOE: Not required when ordering. his condition varies with spool code. old: Designates ier I products and options. Non-bold: Designates ier II products and options. hese products will have longer lead times. 173 Elyria, Ohio, US

173 Dimensions Series D81V Inch equivalents for millimeter dimensions are shown in (**) ir Operated Note: 57mm (2.24") from bottom of bolt hole counterbore to bottom of valve. D81.indd, dd 174 Elyria, Ohio, US

174 echnical Information Series D81VL General Description Series D81VL directional control valves are 5-chamber, lever operated valves. hey are available in 2 or 3-position styles. hese valves are manifold or subplate mounted, and conform to NF s D08, CEO 8 mounting pattern. Specifications Mounting attern NF D08, CEO 8, NG25 Max. Operating 350 ar (5000 SI) ressure Max. ank Line Internal Drain Model ressure 34 ar (500 SI) External Drain Model 350 ar (5000 SI) Maximum Drain 34 ar (500 SI) ressure Maximum Flow See Reference Data Charts ilot Oil Min 6.9 ar (100 SI) ressure Oil Max 350 ar (5000 SI) Response ime Varies with pilot line size and length, pilot pressure, pilot valve shift time & flow capacity (GM) Ordering Information D 81V L Directional Control Valve NF D08 CEO 8 Code Symbol Code Symbol * 008* 030** 009** asic Valve Lever Operated ilot * 008 & 020 spools have closed crossover. ** 009 & 030 spools have open crossover. Spool Style ilot Supply Seal Valve and Drain Variations N Nitrile Omit Standard V Fluorocarbon 1 Int. pilot/ext. drain 2 Ext. pilot/ext. drain 4# Int. pilot/int. drain 5 Ext. pilot/int. drain # Not available with 002, 008, 009 & 030 spools. Symbol Sgl. operator, 2 position, spring offset. to and to in offset position. C Dbl. operator, 3 position, spring centered. D Dbl. operator, 2 position, detent. 7 ilot Choke Meter Out 8 Stroke dj. 9 Stroke dj. 60 ilot Choke Meter In 89 Stroke dj. & Design Series NOE: Not required when ordering. Valve schematic symbols are per NF/NSI standards, providing flow to when energizing operator. Note operators reverse sides for #9 spool. See installation information for details. E Sgl. operator, 2 position, spring centered. to and to in shifted position. H Sgl. operator, 2 position, spring offset. to and to in offset position. K Sgl. operator, 2 position. Spring centered. to and to in shifted position. his condition varies with spool code. Valve Weight: 19.6 kg (43.2 lbs.) Standard olt Kit: K228 Metric olt Kit: KM228 vailable with 020 & 030 spools only. old: Designates ier I products and options. Non-old: Designates ier II products and options. hese products will have longer lead times. D81.indd, dd 175 Elyria, Ohio, US

175 Dimensions Series D81VL Inch equivalents for millimeter dimensions are shown in (**) Lever Operated Note: 57mm (2.24") from bottom of bolt hole counterbore to bottom of valve. D81.indd, dd 176 Elyria, Ohio, US

176 echnical Information Series D8 General Description Series D8 directional control valves are 5-chamber, pilot operated valves. hey are available in 2 or 3-position styles. hese valves are manifold or subplate mounted, and conform to NF s D08, CEO 8 mounting pattern. Features Low pressure drop design. Hardened spools provide long life. Specifications Mounting attern NF D08, CEO 8, NG25 Max. Operating ressure 345 ar (5000 SI) Max. ank Line ressure 345 ar (5000 SI) Max. Drain ressure 345 ar (5000 SI) Min. ilot ressure 5.1 ar* (75 SI) Max. ilot ressure 345 ar (5000 SI) Nominal Flow 302 LM (80 GM) Max. Flow See Reference Data Chart * 6.9 ar (100 SI) for 2, 8, 9 & 12 spools For flow path, pilot drain and pilot pressure details, see Installation Information. Ordering Information D 8 Response ime Response time will vary with pilot line size, pilot line length, pilot pressure shift time and flow capacity of the control valve. Shift Volume he pilot chamber requires a volume of 1.35 in 3 (22.1 cc) for center to end. Directional Control Valve NF D08 CEO 8 DIN NG25 Code Symbol Code Symbol * 7 30** asic Valve ctuator Spool Style ilot Supply Seal Valve and Drain Variations Oil Operator Code ype N Nitrile V Fluorocarbon 2 Ext. ilot / Ext. Drain 5# Ext. ilot / Int. Drain # vailable in and H style only. Symbol Sgl. operator, 2 position, spring offset. to and to in offset position. C Dbl. operator, 3 position, spring centered. Omit Standard 7 ilot Choke Meter Out 8 Stroke dj. End 9 Stroke dj. End 60 ilot Choke Meter In 89 Stroke dj. & Ends Design Series NOE: Not required when ordering. 9** his condition H Sgl. operator, 2 position, spring offset. to varies with * 20 spool has closed crossover. and to in offset position. spool code. ** 9 & 30 spools have open crossover. vailable with 20 & 30 spools only. Valve schematic symbols are per NF/NSI Valve Weight: 18.9 kg (41.7 lbs.) Standard olt Kit: K228 Metric olt Kit: KM228 standards, providing flow to when energizing operator X. Note operators reverse sides for #9 spool. See installation information for details. old: Designates ier I products and options. Non-old: Designates ier II products and options. hese products will have longer lead times. D81.indd, dd 177 Elyria, Ohio, US

177 Dimensions Series D8 Inch equivalents for millimeter dimensions are shown in (**) Standard ilot Operated ilot Operated with ilot Choke Control 39.6 (1.56) ilot Choke Control Variation (8.37) Note: 57mm (2.24") from bottom of bolt hole counterbore to bottom of valve. D81.indd, dd 178 Elyria, Ohio, US

178 echnical Information Series D81V, D8 Installation Information FOR MXIMUM VLVE RELIILIY, DHERE O HE FOLLOWING INSLLION INFORMION. he following is important installation information which applies to all directional control valves described in this catalog. Mounting osition Detent Horizontal Spring Offset Unrestricted Spring Centered Unrestricted Fluid Recommendations remium quality hydraulic oil with a viscosity range between cst. ( SSU) t 38 C (100 F) is recommended. he absolute operating viscosity range is from cst. ( SSU). Oil should have maximum anti-wear properties and rust and oxidation treatment. Silting Silting can cause any sliding spool valve to stick and not spring return if held under pressure for long periods of time. he valve should be cycled periodically to prevent sticking. Special Installations Consult your arker representative for any application requiring the following: ressure above rating. Fluid other than those specified. Oil temperature above 71.1 C (160 F). Flow path other than normal. Mounting atterns Series NF CEO D81V*, D8 D08 3/4 Fluids and Seals Valves using synthetic, fire-resistant fluids require special seals. When phosphate esters or its blends are used, FLUOROCRON seals are required. Waterglycol, water-in-oil emulsions and petroleum oil may be used with SNDRD seals. orque Specifications he recommended torque values for the bolts which mount the valve to the manifold or subplate are as follows: Nm (100 ft-lbs). Filtration For maximum valve and system component life, the system should be protected from contamination at a level not to exceed 125 particles greater than 10 microns per milliliter of fluid (SE class 4/ISO 16/13). D81.indd, dd 179 Elyria, Ohio, US

179 Installation Information Series D81V Series D81VW, D81V, D81VL ank and Drain Line Surges If several valves are piped with a common tank or drain line, flow surges in the line may cause an unexpected spool shift. Detent style valves are most susceptible to this. Separate tank and drain lines should be piped in installations where line surges are expected. Electrical Characteristics (Detented Spool) Only a momentary energizing of the solenoid is necessary to shift and hold a detented spool. Minimum duration of the signal is 0.1 seconds for DC voltages. For C voltages the response time is 0.06 seconds. Spool position will be held provided the spool centerline is in a horizontal plane, and not shock or vibration is present to displace the spool. Electrical Failure or Loss of ilot ressure (D81V or D81V) Should electric power fail or loss of pilot pressure occur, spring offset and spring centered valves will shift to the spring held position. Detented valves will stay in the last position held before power failure. If main flow does not fail or stop at the same time power fails, machine actuators may continue to function in an undesirable manner or sequence. ilot/drain Characteristics ilot ressure: 5.1 to 345 ar (75 to 5000 SI) 6.9 ar (100 SI) for spools 002, 007, 008, 009 & 014 External: n oil source sufficient to maintain minimum pilot pressure must be connected to the X port of the main body. When using the external pilot variation, a 1/16" pipe plug must be present in the main body pilot passage. (For details see Dimension pages.) his plug will be furnished in valves ordered with pilot code 2, 3, 5 or 6. D81V* Flow aths D81.indd, dd Internal: Flow is internally ported from the pressure port of the main valve body to the port of the pilot valve. he pressure developed at the port of the pilot valve must be 5.1 ar (75 SI) minimum at all times or 6.9 ar (100 SI) for spools 002, 007, 008, 009 & 014. Integral Check: Valves using internal pilot and internal drain with an open center spool (spools 2, 7, 8 & 9) can be ordered with an integral check valve in the pressure port of the main valve codes 3 & 6. ilot oil will be internally ported from the upstream side of this check to the port of the pilot valve, ensuring sufficient pilot pressure. 1/16 pipe plug will be present in the main body. he X port in the subplate must be plugged when using the integral check. ilot Valve Drain: Maximum pressure 102 ar (1500 SI) C optional, 207 ar (3000 SI) DC standard. External: When using an external drain, a M6 x 1 x 6mm long set screw must be present in the main body drain passage. (For details see Dimension pages.) his plug will be furnished in valves ordered with drain code 1, 2 or 3. Drain flow from the pilot valve is at the Y port of the main body and must be piped directly to tank. Maximum drain line pressure is 102 ar (1500 SI), C optional, 207 ar (3000 SI) DC standard. ny drain line back pressure is additive to the pilot pressure requirement. Internal: Drain flow from the pilot valve is internally connected to the main valve tank port. ank and drain pressure are then identical so tank line pressure should not exceed 102 ar (1500 SI) C optional, 207 ar (3000 SI) DC standard. ny tank line back pressure is also additive to the pilot pressure requirement. If flow surges (a cause of pressure surges) are anticipated in the tank line, an external drain variation is recommended. he Y port in the subplate must be plugged when using an internal drain. Style No Solenoid/Operator Solenoid/Operator Solenoid/Operator Energized Energized Energized Spring Offset and and C Spring Centered Centered and and D Detented Last osition Held and and E Spring Centered Centered and F Spring Offset, Shift to Center and Centered H Spring Offset and and K Spring Centered Centered and M Spring Offset, Shift to Center and Centered D81VW only. 180 Elyria, Ohio, US

180 Installation Information Series D8 Series D8 ank and Drain Line Surges If several valves are piped with a common tank or drain line, flow surges in the line may cause an unexpected spool shift. Detent style valves are most susceptible to this. Separate tank and drain lines should be piped in installations where line surges are expected. Loss of ilot ressure Should a loss of pilot pressure occur, spring offset and spring centered valves will shift to the spring held position. No spring valves will stay in the last position held. If main hydraulic flow does simultaneously stop, machine actuators may continue to function in an undesirable manner or sequence. ilot Drain Characteristics ilot ressure: 5.1 to 350 ar (75 to 5000 SI) 6.9 ar (100 SI) for spools 2, 7, 8, 9 & 14 Direct pilot operated valves use the X and Y ports to supply pilot oil directly to the ends of the spool, providing spool shifting force. block mounted on top of the valve body is internally cored to make the necessary connections. hus when X is pressurized, Y is used as a drain; and when Y is pressurized, X becomes the drain. ny back pressure in these lines when they are being used as a drain is additive to the pilot pressure requirement. Internal Drain: On spring offset models, only the X port is pressurized, as the spring returns the spool to its at rest position. On these models, Y may be internally drained through the main tank passage in the valve. Flow ath/ilot ressure Style Code Recommended Description X & Y X ort Y ort Special Notes Control Valve De-ressurized ressurized ressurized For ilot Oil wo osition X ort may be pressurized to Spring Offset,,, assist spring in returning spool to offset position (ext. only) hree osition Flow paths will be reversed on C Spring Centered Center,, valves with tandem center (9) spools wo-osition Y ort may be pressurized H Spring Offset,,, to assist spring in returning spool to offset position D81.indd, dd 181 Elyria, Ohio, US

181 Catalog HY /US Installation Information Subplate Mounting NF D08, CEO 8 & NG25 Recommended Mounting Surface Surface must be flat within.102 mm ( inch).i.r and smooth within micro-meters (32 micro-inch). orque bolts to Nm (100 ft-lbs). Mounting osition Valve ype Detent (Solenoid) Spring Offset Spring Centered Mounting osition Horizontal Unrestricted Unrestricted Series D81V, D8 For maximum valve reliability, adhere to the following installation information. Mounting attern NF D08, CEO 8 & NG25 Inch equivalents for millimeter dimensions are shown in (**) (6.00) (5.13) (3.97) (4.44) 94.5 (3.72) (0.69) 4.8 (0.19) 77.0 (3.03) 29.4 (1.16) 53.2 (2.09) 17.5 (0.69) ½ 13 UNC 2x22.22 min th'd dp. (M12 x0.875) 6 holes 0.28 S (0.011) (5.12) 92.1 (3.63) (2.94) 73.0 (2.88) O11.2 (0.441) max. 3 holes 0.56 L (0.022) O (0.922) max. 4 holes 0.56 L (0.022) O /.272 x0.31 min dp. (7.32 / 6.91 x 8) 2 holes 0.28 L (0.011) D81.indd, dd 182 Elyria, Ohio, US

182 echnical Information Series D9L General Description Series D9L directional control valves are 5-chamber, 4 way, 2 0r 3-position valves. hey are operated by a hand lever which is directly connected to the spool. he hand lever can be located either on the or side. Spring offset and detent designs are available. Features Streamlined internal channels ensure minimum pressure drop at maximum flow. Hardened spools provide long life. Specifications General ctuation Size Mounting Interface Mounting osition mbient emperature Hydraulic Maximum Operating ressure Lever NG25 DIN ISO 4401 NF D08 CEO R 121-H Unrestricted, preferably horizontal -25 C to +50 C (-13 F to +122 F) External Drain,,, 350 ar (5075 SI) X, Y 10 ar (145 SI) Internal Drain,, 350 ar (5075 SI), X, Y 10 ar (145 SI) Hydraulic (cont.) Fluid Fluid emperature Viscosity ermitted Viscosity Recommended Hydraulic oil in accordance with DIN / C to +70 C (-13 F to +158 F) 2.8 to 400 cst / mm 2 /s (13 to 1854 SSU) 30 to 80 cst / mm 2 /s (139 to 371 SSU) Filtration ISO 4406 (1999); 18/16/13 (meet NS 1638: 7) Maximum Flow 700 LM (185.2 GM) Leakage at 350 ar (5075 SI) up to 800 ml per minute (per flow path) (depending on spool) D81.indd, dd 183 Elyria, Ohio, US

183 Ordering Information Series D9L D Directional Control Valve 9 asic Valve NF D08 CEO 8 DIN NG25 32 mm ctuator Spool Style ilot Supply and Drain Code N V Seal Description Nitrile Fluorocarbon Design Series NOE: Not required when ordering. Code L L ctuation Lever Side Lever Side Code Description 2* External ilot External Drain 5** External ilot Internal Drain * ressure -port < 10 bar ** ressure -port > 10 bar Code Symbol Code Symbol Symbol Single operator, 2 position, spring offset. C D E H K N Double operator, 3 position, spring centered. Double operator, 2 position, detent. Single operator, 2 position, spring centered. Single operator, 2 position, spring offset. Single operator, 2 position, spring centered. Double operator, 3 position, detent. Weight: 17.0 kg (37.5 lbs.) D81.indd, dd 184 Elyria, Ohio, US

184 erformance Curves Series D9L he flow curve diagram shows the flow versus pressure drop curves for all spool types. he relevant curve number for each spool type, operating position and flow direction is given in the table below. Spool Curve Number Code D81.indd, dd 185 Elyria, Ohio, US

185 Dimensions Series D9L Inch equivalents for millimeter dimensions are shown in (**) D9L D9L Surface Finish Seal K360 6x M5x75 DIN Nm ±15% Nitrile: SK-D9LN Fluorocarbon: SK-D9LV D81.indd, dd 186 Elyria, Ohio, US

186 Catalog HY /US Introduction pplication Series D101 hydraulic directional control valves are high performance, solenoid controlled, pilot operated, 2-stage, 4-way valves. hey are available in 2 or 3-position styles and are manifold mounted. hese valves conform to NF s D10, CEO 10 mounting pattern. Operation Series D101 directional valves consist of a 5-chamber style main body, a case hardened sliding spool, and a pilot valve or pilot operators (hydraulic or pneumatic). Series D101 Features Easy access mounting bolts. 210 ar (3000 SI) pressure rating. Flows to 950 LM (250 GM) depending on spool. Choice of four operator styles. Rugged four land spools. Low pressure drop. hosphate finish. D101VW Solenoid Operated lug-in Conduit ox D101VL Lever Operated D10 Oil ilot Operated D101V ir ilot Operated D101.indd, dd 188 Elyria, Ohio, US

187 echnical Information Series D101V General Description Series D101V directional control valves are 5-chamber, pilot operated, solenoid controlled valves. hey are available in 2 or 3-position styles. hese valves are manifold or subplate mounted, and conform to NF s D10, CEO 10 mounting pattern. Operation Series D101V pilot operated valves are standard with low shock spools and pilot orifice. he orifice can be removed if a faster shift is required. However, it is recommended that all systems operating above 138 ar (2000 SI) use the standard valve to avoid severe shock. Features Low pressure drop design. Hardened spools provide long life. Fast response option available. Wide variety of voltags and electrical connection options. Explosion proof availability. No tools required for coil removal. Specifications Mounting attern Maximum Operating ressure Maximum ank Line ressure Maximum Drain ressure Minimum ilot ressure Maximum ilot ressure Nominal Flow Maximum Flow NF D10, CEO 10, NG ar (3000 SI) Standard CS 207 ar (3000 SI) Internal Drain Model: 102 ar (1500 SI) C Only 207 ar (3000 SI) DC Standard/C Optional External Drain Model: 207 ar (3000 SI) CS 102 ar (1500 SI) 102 ar (1500 SI) C Only 207 ar (3000 SI) DC Standard/C Optional CS 102 ar (1500 SI) 4.4 ar (65 SI) 207 ar (3000 SI) Standard CS 207 ar (3000 SI) 378 LM (100 GM) See Reference Chart Response ime Response times (milliseconds) are measured at 205 ar (3000 SI) and 416 LM (110 GM) with various pilot pressures as indicated. Solenoid ilot ull-in Drop-Out ype ressure Std Fast Std Fast DC C ecause of the high drain line pressure transients generated during shifting, use of the fast response option is not recommended for pilot pressures exceeding 205 ar (2000 SI). D101.indd, dd 189 Elyria, Ohio, US

188 Ordering Information Series D101V D Directional Control Valve 101V asic Valve ctuator Spool Style ilot Supply Seal Solenoid and Drain Voltage NF D10 CEO 10 DIN NG32 D03 ilot Code N V Description Nitrile Fluorocarbon W* Solenoid, Wet in, Screw-in HW* Reversed Wiring * Valve schematic symbols are per NF/ NSI standards, providing flow to when energizing solenoid. Note operators reverse sides for #008 and #009 spools. See installation information for details. o configure per DIN standards ( coil over port, coil over port) code valves as D101VHW***. Code Symbol * 008 spool has closed crossover. ** 009 spool has open crossover. Code * 009** 011 Symbol 1 Internal ilot, External Drain 2 External ilot, External Drain 3 Internal ilot w/check, External Drain 4# Internal ilot, Internal Drain 5 External ilot, Internal Drain 6 Internal ilot w/check, Internal Drain # Not available with 002, 007, 008 and 009 spools. * 24/50 VC D 120 VDC G 198 VDC J 24 VDC K 12 VDC N** 220/50 VC Q* 100/60 VC QD 100 VC/50 Hz 100 VC/60 Hz R 24/60 VC 240/60-220/50 VC U 98 VDC Y 120/60-110/50 VC Z 250 VDC * High Watt only. ** Explosion roof only. DIN style only. Symbol * Single solenoid, 2 position, spring offset. to and to in offset position. C Double solenoid, 3 position, spring centered. D* Double solenoid, 2 position, detent. E F Single solenoid, 2 position, spring centered. to and to when energized. Single solenoid, 2 position, spring offset, energized to center. osition spool spacer on side. to and to in spring offset position. H* Single solenoid, 2 position, spring offset. to and to in offset position. K Single solenoid, 2 position, spring centered. to and to when energized. M Single solenoid, 2 position, spring offset, energized to center position. Spool spacer on side. to and to in spring offset position. * vailable with 001, 002, 004 and 011 spools only. b b b b b a a a a a D101.indd, dd old: Designates ier I products and options. Non-bold: Designates ier II products and options. hese products will have longer lead times. 190 Elyria, Ohio, US

189 Ordering Information Series D101V Solenoid Connection C* Leadwire Conduit ox D** Metric lug (M12X1), DESIN E Explosion roof G lug-in Conduit ox J# Deutsch (D06-2S) M# Metri-ack (150) DIN with lug S# Dual Spade W DIN w/o lug * No variations See lug-in. ** DC only, lights, diode surge suppressor, not CS approved. Not available with lights. Required for variations on conduit box style. Must have lights. # DC only, no lights, not CS approved. Coil Options Omit* High Watt D** Explosion roof, EEXD EX E** Explosion roof, EEXME EX F Low Watt L 10 Watt O** Explosion roof, MSH # Explosion roof, Ex d IIC EX/CS U ** Explosion roof, UL/CS * C ambient temperature must not exceed 60 C (140 F). ** 60 Hz only on C, no options. C only. DC and C rectified only. # J, K and Y voltages only. Dual frequency on C, no options. ube Options Code Omit Manual Override Options Omit Standard Extended with oot * None * DC or C Rectified only. Manual Override options not available with Explosion roof. Description Standard ressure ar (1500 SI) C 207 ar (3000 SI) DC H* High ressure, C only 207 ar (3000 SI) * Not available with CS. Electrical Options Shift Response and Indication Code Omit I3 I6 Note: Omit No Options J* Diode Surge Suppressor Z Rectified Coil * DC only. DIN coil must include plug with lights. DC tube standard. pprovals Description Standard Response, No Switch Monitor Switch, & ort End Monitor Switch, & ort Start Not CE or CS approved. Not available with F or M styles. Valve Design Variations Series NOE: Not required when ordering. See next page Omit Standard Valve 3* CS US (UL 429) 4*# CS pproved * Not available with C high pressure tube., C, H styles only. J, K, Y, U voltages only with C, G, W solenoid connections only. Conforms to UL429. # Valve is derated. Valve Weight: Double Solenoid 35.0 kg (77.1 lbs.) Standard olt Kit: K229 Seal Kit: Nitrile SKD101VWN91 Fluorocarbon SKD101VWV91 D101.indd, dd old: Designates ier I products and options. Non-bold: Designates ier II products and options. hese products will have longer lead times. 191 Elyria, Ohio, US

190 Ordering Information Series D101V Valve Variations 5* Signal Lights Standard Signal Lights Hirsch. (DIN with lug) 7** Manaplug rad Harrison (12x1) Micro with Lights 56** Manaplug (Mini) with Lights 20 Fast Response 1C** Manaplug (Mini) Single Sol. 5-pin, with Lights 1D** Manaplug (Micro) Single Sol. 5-pin, with Lights 1G** Manaplug (Mini) Single Sol. 5-pin, with Stroke djust & End and Lights 1H** Manaplug (Micro) Single Sol. 5-pin, with Stroke djust & End and Lights 1M** Manaplug Opposite Normal 1 ainted ody 1R Stroke djust & End with ilot Choke Meter In 3 ilot Choke Meter Out 3 ilot Choke Meter In 3C ilot ressure Reducer 3D Stroke djust End 3E Stroke djust End 3F Stroke djust & End 3G* ilot Choke Meter Out with Lights 3H* ilot Choke Meter In with Lights 3J* ilot ressure Reducer with Lights 3K ilot Choke Meter Out with Stroke djust & End 3L** ilot Choke Meter Out, Stroke djust & End with Lights and Manaplug rad Harrison Mini 3M ilot Choke Meter Out, ilot ressure Reducer, Stroke djust & End 3R ilot Choke Meter Out & ilot ressure Reducer 3S** Lights, Mini Manaplug, ilot Choke Meter Out 7Y** M12x1 Manaplug (4-pin), Special Wiring, and Lights * DESIN, plug-in conduit box, and DIN with plug styles only. ** Must have plug-in style conduit box. D101.indd, dd old: Designates ier I products and options. Non-bold: Designates ier II products and options. hese products will have longer lead times. 192 Elyria, Ohio, US

191 echnical Information Series D101V Reference Data MaximumFlow, Maximum Flow, LM (GM) LM (GM) Spool 205 ar (3000 SI) Spool 205 ar (3000 SI) Model Symbol w/o Malfunction Model Symbol w/o Malfunction D101V* (250) D101V* (250) D101V* (250) D101V* (80) D101V* (250) D101V*008 D101V* (130) D101V* (250) D101V* (250) D101V* (250) D101VW Series ressure Drop Chart he following chart provides the flow vs. pressure drop curve reference for the Series D101VW valve by spool type. VISCOSIY CORRECION FCOR Viscosity (SSU) % of (pprox.) Curves were generated using 100 SSU hydraulic oil. For any other viscosity, pressure drop will change as per chart. D101VW ressure Drop Reference Chart -- Curve Number Spool No / erformance Curves SI ar ressure Drop LM 0 GM Flow D101.indd, dd 193 Elyria, Ohio, US

192 Catalog HY /US echnical Information Solenoid Ratings Insulation System llowable Deviation from rated voltage rmature CS File Number Environmental Capability Class F -15% to +10% for DC and C rectified coils -5% to +5% for C Coils Wet pin type LR60407 DC Solenoids meet NEM 4 and I67 when properly wired and installed. Contact HVD for C coil applications. Series D101V Explosion roof Solenoid Ratings* U.L. & CS (EU) Class I, Div 1 & 2, Groups C & D Class II, Div 1 & 2, Groups E, F & G s defined by the N.E.C. MSH (EO) Complies with 30CFR, art 18 EX (ED) Complies with EX requirements for: Exd, Group II; EN50014: mds. 1 & 2, EN50018: 2000 EX & CS/US (E) Complies with EX EN , EN Ex d IIC; CS/US Ex d IIC, Ex d IIC for Class I, Zone 1, UL1203, UL1604, CS E61241,1 Class II, Div 1 * llowable Voltage Deviation ±10%. Note that Explosion roof C coils are single frequency only. Code Voltage In Rush mps In Rush Holding mps Watts Resistance Voltage ower mperage 3MM Code Code D L 120 VDC N/ N/ 0.09 mps 10 W ohms D Omit 120 VDC N/ N/ 0.26 mps 30 W ohms G Omit 198 VDC N/ N/ 0.15 mps 30 W ohms J L 24 VDC N/ N/ 0.44 mps 10 W ohms J Omit 24 VDC N/ N/ 1.32 mps 30 W ohms K L 12 VDC N/ N/ 0.88 mps 10 W ohms K Omit 12 VDC N/ N/ 2.64 mps 30 W 4.32 ohms L L 6 VDC N/ N/ 1.67 mps 10 W 3.59 ohms L Omit 6 VDC N/ N/ 5.00 mps 30 W 1.20 ohms Q Omit 100 VC / 60 Hz 2.05 mps 170 V 0.77 mps 30 W ohms QD F 100 VC / 60 Hz 1.35 mps 135 V 0.41 mps 18 W ohms QD F 100 VC / 50 Hz 1.50 mps 150 V 0.57 mps 24 W ohms R F 24/60 VC, Low Watt 6.67 mps 160 V 2.20 mps 23 W 1.52 ohms Omit 240/60 VC 0.83 mps 199 V 0.30 mps 30 W ohms Omit 220/50 VC 0.87 mps 191 V 0.34 mps 30 W ohms F 240/60 VC, Low Watt 0.70 mps 168 V 0.22 mps 21 W ohms F 220/50 VC, Low Watt 0.75 mps 165 V 0.26 mps 23 W ohms U L 98 VDC N/ N/ 0.10 mps 10 W ohms U Omit 98 VDC N/ N/ 0.31 mps 30W ohms Y Omit 120/60 VC 1.7 mps 204 V 0.60 mps 30 W ohms Y Omit 110/50 VC 1.7 mps 187 V 0.68 mps 30 W ohms Y F 120/60 VC, Low Watt 1.40 mps 168 V 0.42 mps 21 W ohms Y F 110/50 VC, Low Watt 1.50 mps 165 V 0.50 mps 23 W ohms Z L 250 VDC N/ N/ 0.04 mps 10 W ohms Z Omit 250 VDC N/ N/ 0.13 mps 30 W ohms Explosion roof Solenoids R 24/60 VC 7.63 mps 183 V 2.85 mps 27 W 1.99 ohms 240/60 VC 0.76 mps 183 V 0.29 mps 27 W 1.34 ohms N 220/50 VC 0.77 mps 169 V 0.31 mps 27 W 1.38 ohms Y 120/60 VC 1.60 mps 192 V 0.58 mps 27 W ohms 110/50 VC 1.47 mps 162 V 0.57 mps 27 W ohms K 12 VDC N/ N/ 2.75 mps 33 W 4.36 ohms J 24 VDC N/ N/ 1.38 mps 33 W ohms "E" Explosion roof Solenoids K 12 VDC N/ N/ 1.00 mps 12 W ohms J 24 VDC N/ N/ 1.00 mps 13 W ohms Y 120/60-50 VC N/ N/ 0.16 mps 17 W ohms D101.indd, dd 194 Elyria, Ohio, US

193 Dimensions Series D101V Inch equivalents for millimeter dimensions are shown in (**) lug-in Conduit ox, Double C Solenoid D101.indd, dd Note: 36.83mm (1.45") from bottom of bolt hole counterbore to bottom of valve. 195 Elyria, Ohio, US

194 Dimensions Series D101V Inch equivalents for millimeter dimensions are shown in (**) Conduit ox and Stroke djust, Double C Solenoid Note: 36.83mm (1.45") from bottom of bolt hole counterbore to bottom of valve. Conduit ox and ilot Choke Control, Double C Solenoid Conduit ox, Single C Solenoid D101.indd, dd Note: 36.83mm (1.45") from bottom of bolt hole counterbore to bottom of valve. 196 Elyria, Ohio, US

195 Dimensions Series D101V Inch equivalents for millimeter dimensions are shown in (**) lug-in Conduit ox, Double DC Solenoid D101.indd, dd Note: 36.83mm (1.45") from bottom of bolt hole counterbore to bottom of valve. 197 Elyria, Ohio, US

196 Dimensions Series D101V Inch equivalents for millimeter dimensions are shown in (**) lug-in Conduit ox and Stroke djust, Double DC Solenoid Note: 36.83mm (1.45") from bottom of bolt hole counterbore to bottom of valve. Hirschmann and ilot Choke Control, Double DC Solenoid lug-in Conduit ox, Single DC Solenoid D101.indd, dd Note: 36.83mm (1.45") from bottom of bolt hole counterbore to bottom of valve. 198 Elyria, Ohio, US

197 Dimensions Series D101V Inch equivalents for millimeter dimensions are shown in (**) lug-in Conduit ox, Double DC Solenoid with Variation I3 or I6 (Monitor Switch) Monitor Switch (Variation I3 and I6) his feature provides for electrical confirmation of the spool shift. his can be used in safety circuits, to assure proper sequencing, etc. Switch Data in 1 and in 3 have outputs equal to the input. When the monitor switch has the output to in 1, in 3 will have an output of zero, and vice-versa. When the valve is switched, in 1 and in 3 will switch outputs. IN 2 Input VDC osition Control Switch Sensor / Driver Circuitry Load 0.2 Max IN 1 IN 3 Outputs D101.indd, dd 199 Elyria, Ohio, US

198 Catalog HY /US ccessories Manaplug (Options 6, 56, 1 & 1C) Interface rad Harrison lug 3-in for Single Solenoid 5-in for Double Solenoid Ground Wire #1 (Green) Series D101V Micro Connector Options (7, 7, 1 & 1D) Solenoid (Negative) Wire #3 (Red/lack) Solenoid (ositive) Wire #2 (Red/White) 3-in Manaplug (Mini) with Lights Single Solenoid Valves Installed Opposite Side of Solenoid ins are as seen on valve (male pin connectors) Manaplug Electrical Mini lug E E E in lug 5 in lug (Double Solenoid) 5 in lug (Single Solenoid) Conduit ox Option C No Wiring Options vailable Manaplug Electrical Micro lug E E E in lug 5 in lug (Double Solenoid) 5 in lug (Single Solenoid) Signal Lights (Option 5) lug-in Only LED Interface Meets Nema 4/I67 Hirschmann lug with Lights (Option 5) ISO 4400/DIN Form D101.indd, dd in #2 (ositive) Face View of lug in #3 (Ground) in #1 (Negative) DESIN Connector (Option D) M12 pin assignment Standard 1 = Not used 2 = Not used 3 = 0V 4 = Signal (24 V) 5 = Earth Ground ins are as seen on valve (male pin connectors) DESIN design in 1 and 2 connected Elyria, Ohio, US

199 echnical Information Series D101V General Description Series D101V directional control valves are 5-chamber, air pilot operated valves. hey are available in 2 or 3-position styles. hese valves are manifold or subplate mounted, and conform to NF s D10, CEO 10 mounting pattern. Specifications Mounting attern Max. Operating ressure Max. ank ressure Max. Drain ressure Maximum Flow NF D10, CEO 10, NG ar (3000 SI) Internal Drain Model: 34 ar (500 SI) External Drain Model: 207 ar (3000 SI) 34 ar (500 SI) See Reference Chart ilot ressure ir Min 3.4 ar (50 SI) ir Max 10.2 ar (150 SI) Response ime Varies with pilot line size and length, pilot pressure, pilot valve shift time & flow capacity (GM) Ordering Information Features Low pressure drop design. Hardened spools provide long life. D Directional Control Valve D101.indd, dd 101V asic Valve NF D10 CEO 10 Valve schematic symbols are per NF/NSI standards, providing flow to when energizing operator. Note operators reverse sides on #8 and #9 spools. See installation information for details. Code Symbol * 8 spool has closed crossover. ** 9 spool has open crossover. Valve Weight: 35.3 kg (77.8 lbs.) Standard olt Kit: K229 Metric olt Kit: KM * 9** 11 ir Operated ilot Spool Style ilot Supply Seal Valve and Drain Code N V ype Nitrile Fluorocarbon 1 Int. pilot/ext. drain 2 Ext. pilot/ext. drain 4# Int. pilot/int. drain 5 Ext. pilot/int. drain # Not available with 2, 8 & 9 spools. Symbol Sgl. operator, 2 position, spring offset. to and to in offset position. C Dbl. operator, 3 position, spring centered. H Sgl. operator, 2 position, spring offset. to and to in offset position. Design Variations Series NOE: Not required when ordering. Omit Standard 7 ilot Choke Meter Out 8 Stroke dj. End 9 Stroke dj. End 60 ilot Choke Meter In 89 Stroke dj. & Ends 90 1/4 Shreads vailable with 1, 2, 4 & 11 spools only. his condition varies with spool code. old: Designates ier I products and options. Non-old: Designates ier II products and options. hese products will have longer lead times. b b a a 201 Elyria, Ohio, US

200 Dimensions Series D101V Inch equivalents for millimeter dimensions are shown in (**) ir Operated D101.indd, dd Note: 36.83mm (1.45") from bottom of bolt hole counterbore to bottom of valve. 202 Elyria, Ohio, US

201 echnical Information Series D101VL General Description Series D101VL directional control valves are 5-chamber, lever operated valves. hey are available is 2 or 3-position styles. hese valves are manifold or subplate mounted, and conform to NF s D10, CEO 10 mounting pattern. Specifications Mounting attern Max. Operating ressure Max. ank ressure Max. Drain ressure Maximum Flow Ordering Information NF D10, CEO 10, NG ar (3000 SI) Internal Drain Model: 34 ar (500 SI) External Drain Model: 207 ar (3000 SI) 34 ar (500 SI) See Reference Chart ilot ressure Oil Min 6.9 ar (100 SI) Oil Max 207 ar (300 SI) Response ime Varies with pilot line size and length, pilot pressure, pilot valve shift time & flow capacity (GM) Features Low force required to shift spool. Hardened spools provide long life. Low pressure drop design. D Directional Control Valve D101.indd, dd 101V asic Valve NF D10 CEO 10 Code Symbol * 8 spool has closed crossover. ** 9 spool has open crossover. Valve schematic symbols are per NF/NSI standards, providing flow to when energizing operator. Note operators reverse sides on #8 and #9 spools. See installation information for details * 9** 11 L Lever Operated ilot Spool Style ilot Supply Seal Valve and Drain Variations Code N V Code Supply Drain 1 Int. pilot/ext. drain 2 Ext. pilot/ext. drain 4# Int. pilot/int. drain 5 Ext. pilot/int. drain # Not available with 2, 8 & 9 spools. ype Nitrile Fluorocarbon Symbol Sgl. operator, 2 position, spring offset. to and to in offset position. C Dbl. operator, 3 position, spring centered. H Sgl. operator, 2 position, spring offset. to and to in offset position. vailable with 1, 2, 4 & 11 spools only. old: Designates ier I products and options. Non-old: Designates ier II products and options. hese products will have longer lead times. Omit Standard 7 ilot Choke Meter Out 8 Stroke dj. End 9 Stroke dj. End 60 ilot Choke Meter In 89 Stroke dj. & Ends Valve Weight: 35.0 kg (77.2 lbs.) Standard olt Kit: K229 Metric olt Kit: KM229 his condition varies with spool code. Design Series NOE: Not required when ordering. 203 Elyria, Ohio, US

202 Dimensions Series D101VL Inch equivalents for millimeter dimensions are shown in (**) Lever Operated D101.indd, dd Note: 36.83mm (1.45") from bottom of bolt hole counterbore to bottom of valve. 204 Elyria, Ohio, US

203 echnical Information Series D10 General Description Series D10 directional control valves are 5-chamber, pilot operated valves. hey are available in 2 or 3-position styles. hese valves are manifold or subplate mounted, and conform to NF s D10, CEO 10 mounting pattern. Features Low pressure drop design. Hardened spools provide long life. Specifications Mounting attern NF D10, CEO 10, NG32 Max. Operating ressure 207 ar (3000 SI) Max. ank Line ressure Max. Drain ressure Min. ilot ressure Max. ilot ressure Nominal Flow 207 ar (3000 SI) 207 ar (3000 SI) 4.4 ar (65 SI) 207 ar (3000 SI) 378 LM (100 GM) Maximum Flow See Reference Chart For flow path, pilot drain and pilot pressure details, see Installation Information. Ordering Information Response ime Response time will vary with pilot line size, pilot line length, pilot pressure shift time and flow capacity of the control valve. Shift Volume he pilot chamber requires a volume of 1.51 in 3 (24.75 cc) for center to end. D 10 Directional Control Valve D101.indd, dd NF D10 CEO 10 Valve schematic symbols are per NF/NSI standards, providing flow to when energizing operator X. Note operators reverse sides on #8 and #9 spools. See installation information for details. asic Valve ctuator Spool Style ilot Supply Seal Valve and Drain Variations Oil Operator Valve Weight: 34.3 kg (75.7 lbs.) Standard olt Kit: K229 Metric olt Kit: KM229 Code * 9** 11 Symbol * 8 spool has closed crossover. ** 9 spool has open crossover. Code ype N Nitrile V Fluorocarbon 2 Ext. ilot / Ext. Drain 5# Ext. ilot / Int. Drain # vailable in & H styles only. Symbol Sgl. operator, 2 position, spring offset. to and to in offset position. C Dbl. operator, 3 position, spring centered. H Sgl. operator, 2 position, spring offset. to and to in offset position. Omit Standard 7 ilot Choke Meter Out 8 Stroke dj. End 9 Stroke dj. End 60 ilot Choke Meter In 89 Stroke dj. & Ends Design Series NOE: Not required when ordering. vailable with 1, 2, 4 & 11 spools only. his condition varies with spool code. old: Designates ier I products and options. Non-old: Designates ier II products and options. hese products will have longer lead times. 205 Elyria, Ohio, US

204 Dimensions Series D10 Inch equivalents for millimeter dimensions are shown in (**) Standard ilot Operated Note: 36.83mm (1.45") from bottom of bolt hole counterbore to bottom of valve. ilot Operated with ilot Choke Control 39.6 (1.56) ilot Choke Control Variation (9.13) Note: 36.83mm (1.45") from bottom of bolt hole counterbore to bottom of valve. D101.indd, dd 206 Elyria, Ohio, US

205 Installation Information FOR MXIMUM VLVE RELIILIY, DHERE O HE FOLLOWING INSLLION INFORMION. he following is important installation information which applies to all directional control valves described in this catalog. Mounting osition Detent Horizontal Spring Offset Unrestricted Spring Centered Unrestricted Fluid Recommendations remium quality hydraulic oil with a viscosity range between cst ( SSU) t 38 C (100 F) is recommended. he absolute operating viscosity range is from cst ( SSU). Oil should have maximum anti-wear properties and rust and oxidation treatment. Series D101V, D10 Silting Silting can cause any sliding spool valve to stick and not spring return if held under pressure for long periods of time. he valve should be cycled periodically to prevent sticking. Special Installations Consult your arker representative for any application requiring the following: ressure above rating. Fluid other than those specified. Oil temperature above 71.1 C (160 F). Flow path other than normal. Mounting atterns Series NF Size D101V*, D10 D10 1-1/4 Fluids and Seals Valves using synthetic, fire-resistant fluids require special seals. When phosphate esters or its blends are used, FLUOROCRON seals are required. Waterglycol, water-in-oil emulsions and petroleum oil may be used with SNDRD seals. orque Specifications he recommended torque values for the bolts which mount the valve to the manifold or subplate are as follows: Nm (300 ft-lbs). Filtration For maximum valve and system component life, the system should be protected from contamination at a level not to exceed 125 particles greater than 10 microns per milliliter of fluid (SE class 4/ISO 16/13). D101.indd, dd 207 Elyria, Ohio, US

206 Installation Information Series D101V Series D101VW, D101V, D101VL ank and Drain Line Surges If several valves are piped with a common tank or drain line, flow surges in the line may cause an unexpected spool shift. Detent style valves are most susceptible to this. Separate tank and drain lines should be piped in installations where line surges are expected. Electrical Characteristics (Detented Spool) Only a momentary energizing of the solenoid is necessary to shift and hold a detented spool. Minimum duration of the signal is 0.1 seconds for DC voltages. For C voltages the response time is 0.06 seconds. Spool position will be held provided the spool centerline is in a horizontal plane, and not shock or vibration is present to displace the spool. Electrical Failure or Loss of ilot ressure (D101V) Should electric power fail or loss of pilot pressure occur, spring offset and spring centered valves will shift to the spring held position. Detented valves will stay in the last position held before power failure. If main flow does not fail or stop at the same time power fails, machine actuators may continue to function in an undesirable manner or sequence. ilot/drain Characteristics ilot ressure: 4.4 to 207 ar (65 to 3000 SI) External: n oil source sufficient to maintain minimum pilot pressure must be connected to the X port of the main body. When using the external pilot variation, a 1/16" pipe plug must be present in the main body pilot passage. (For details see Dimension pages.) his plug will be furnished in valves ordered with pilot code 2, 3, 5 or 6. Internal: Flow is internally ported from the pressure port of the main valve body to the port of the pilot valve. he pressure developed at the port of the pilot valve must be 4.4 ar (65 SI) minimum at all times. Integral Check: Valves using internal pilot and internal drain with an open center spool (spools 2, 7, 8 & 9) can be ordered with an integral check valve in the pressure port of the main valve codes 3 & 6. ilot oil will be internally ported from the upstream side of this check to the port of the pilot valve, ensuring sufficient pilot pressure. 1/16 pipe plug will be present in the main body. he X port in the subplate must be plugged when using the integral check. ilot Valve Drain: Maximum pressure 102 ar (1500 SI) C standard, 207 ar (3000 SI) C optional/dc standard. External: When using an external drain, a 10 x 24 x 0.31 long set screw must be present in the main body drain passage. (For details see Dimension pages.) his plug will be furnished in valves ordered with drain code 1, 2 or 3. Drain flow from the pilot valve is at the Y port of the main body and must be piped directly to tank. Maximum drain line pressure is 102 ar (1500 SI) C standard, 207 ar (3000 SI) C optional/dc standard. ny drain line back pressure is additive to the pilot pressure requirement. Internal: Drain flow from the pilot valve is internally connected to the main valve tank port. ank and drain pressure are then identical so tank line pressure should not exceed 102 ar (1500 SI) C standard, 207 ar (3000 SI) DC standard/c optional. ny tank line back pressure is also additive to the pilot pressure requirement. If flow surges (a cause of pressure surges) are anticipated in the tank line, an external drain variation is recommended. he Y port in the subplate must be plugged when using an internal drain. Style No Solenoid/Operator Solenoid/Operator Solenoid/Operator Energized Energized Energized Spring Offset and and C Spring Centered Centered and and D Detented Last osition Held and and E Spring Centered Centered and F Spring Offset, Shift to Center and Centered H Spring Offset and and K Spring Centered Centered and M Spring Offset, Shift to Center and Centered D101VW only. D101.indd, dd 208 Elyria, Ohio, US

207 Installation Information Series D10 ank and Drain Line Surges If several valves are piped with a common tank or drain line, flow surges in the line may cause an unexpected spool shift. Detent style valves are most susceptible to this. Separate tank and drain lines should be piped in installations where line surges are expected. Loss of ilot ressure Should a loss of pilot pressure occur, spring offset and spring centered valves will shift to the spring held position. No spring valves will stay in the last position held. If main hydraulic flow does simultaneously stop, machine actuators may continue to function in an undesirable manner or sequence. ilot Drain Characteristics ilot ressure: 4.4 to 207 ar (65 to 3000 SI) Direct pilot operated valves use the X and Y ports to supply pilot oil directly to the ends of the spool, providing spool shifting force. block mounted on top of the valve body is internally cored to make the necessary connections. hus when X is pressurized, Y is used as a drain; and when Y is pressurized, X becomes the drain. ny back pressure in these lines when they are being used as a drain is additive to the pilot pressure requirement. Internal Drain: On spring offset models, only the X port is pressurized, as the spring returns the spool to its at rest position. On these models, Y may be internally drained through the main tank passage in the valve. Flow ath/ilot ressure Style Code Recommended Description X & Y X ort Y ort Special Notes Control Valve De-ressurized ressurized ressurized For ilot Oil wo osition X ort may be pressurized to Spring Offset,,, assist spring in returning spool to offset position (ext. only) hree osition Flow paths will be reversed on C Spring Centered Center,, valves with tandem center (8 & 9) spools wo-osition Y ort may be pressurized H Spring Offset,,, to assist spring in returning spool to offset position D101.indd, dd 209 Elyria, Ohio, US

208 Catalog HY /US Installation Information Subplate Mounting NF D10, CEO 10 & NG 32 Recommended Mounting Surface Surface must be flat within.102 mm ( inch).i.r and smooth within micro-meters (32 micro-inch). orque bolts to Nm (300 ft-lbs). Mounting osition Valve ype Detent (Solenoid) Spring Offset Spring Centered Mounting osition Horizontal Unrestricted Unrestricted Series D101V For maximum valve reliability, adhere to the following installation information. Mounting attern NF D10, CEO 10 & NG32 Inch equivalents for millimeter dimensions are shown in (**) (7.84) Min (6.26) (5.13) (4.88) 79.4 (3.13) 44.5 (1.75) (7.51) (5.82) 82.6 (3.25) 41.3 (1.63) 35.0 (1.38) (6.63) (4.50) 76.2 (3.00) (9.06) Min. M20 x 33.3 (3/4-10 UNC-2 x 1.31) Min. hd. Dp. 6 Holes 0.28 (0.011) (0.441) Max. 3 Holes 0.56 (0.022) (1.250) Max. 4 Holes 7.32/6.91 x 8 Min. Dp. (0.288/0.272 x.31) 2 Holes 0.28 (0.011) 0.56 (0.022) (0.75) R. Max. yp. 4 laces D101.indd, dd 210 Elyria, Ohio, US

209 echnical Information Series D111VW General Description Series D111VW valves are piloted by a D1VW valve. he valves can be ordered with position control. he minimum pilot pressure must be ensured for all operating conditions of the directional valve. dditionally spools with a to connection in the deenergized position need an external pressure supply (external inlet). Features Low pressure drop design. Hardened spools provide long life. Wide variety of voltages and electrical connection options. Explosion proof availability. No tools required for coil removal. erformance Curves he flow curve diagram shows the flow versus pressure drop curves for all spool types. he relevant curve number for each spool type, operating position and flow direction is given in the table below. Spool Curve Number Code ll characteristic curves measured with HL46 at 50 C. D111VW.indd, dd 211 Elyria, Ohio, US

210 Ordering Information Series D111VW D Directional Control Valve 111V asic Valve W ctuator Spool Style ilot Supply and Drain NF 10 CEO 10 DIN NG32 50 mm Solenoid Wet in Code Description 1 Internal ilot External Drain 2 External ilot External Drain 4* Internal ilot Internal Drain 5 External ilot Internal Drain * Not for spools 002, 009, osition Spools Code Spool ype a 0 b Code C 3-osition Spools ll 3-osition Spools 3 positions. Spring offset in position 0. Operated in position a or b. Standard Spool ype 009* E Operated in position a. Operated in position b. 2 positions. Spring offset in position osition Spools Code Spool ype a b 020 F K Spring offset in position b. Operated in position b. Spring offset in position a. Operated in position a. 2 positions. Operated in position 0. 2 positions. Spring offset in position M Spring offset in position a. Spring offset in position b. 2 positions. Operated in position 0. Code H 2-osition Spools Spool osition Spring offset in position b. Operated in position a. Spring offset in position a. Operated in position b. * vailable only with external pilot. Weight: Single Solenoid: Double Solenoid: 67.4 kg (148.6 lbs.) 68.0 kg (149.9 lbs.) D111VW.indd, dd old: Designates ier I products and options. Non-old: Designates ier II products and options. hese products will have longer lead times. 212 Elyria, Ohio, US

211 Ordering Information Series D111VW Seal N Nitrile V Fluorocarbon Solenoid Voltage Solenoid Connection Coil Options ube Options Manual Override Options Electrical Options Shift Response and Indication Valve Variations See next page Design Series NOE: Not required when ordering. * 24/50 VC D 120 VDC G 198 VDC J 24 VDC K 12 VDC N** 220/50 VC Q* 100/60 VC QD 100 VC/60 HZ 100 VC/50 HZ R 24/60 VC 240/60-220/50 VC U 98 VDC Y 120/60-110/50 VC Z 250 VDC * High Watt Coil only. ** Explosion roof only. vailable in DIN only. C* Leadwire Conduit ox D** Metric lug (M12X1), DESIN E Explosion roof G lug-in Conduit ox J# Deutsch (D06-2S) M# Metri-ack (150) DIN with lug S# Dual Spade W DIN w/o lug * No variations See lug-in. ** DC only, lights, diode surge suppressor, not CS approved. Not available with lights. Required for variations on conduit box style. Must have lights. # DC only, no lights, not CS approved. Code Omit Omit Standard Extended with oot None DC or C Rectified only. Manual Override options not available with Explosion roof. Description Standard ressure ar (1500 SI) C 207 ar (3000 SI) DC H* High ressure, C only 207 ar (3000 SI) * Not available with CS. Omit* High Watt D** Explosion roof, EEXD EX E** Explosion roof, EEXME EX F Low Watt L 10 Watt O** Explosion roof, MSH # Explosion roof, Ex d IIC EX/CS U ** Explosion roof, UL/CS * C ambient temperature must not exceed 60 C (140 F). ** 60 Hz only on C, no options. C only. DC and C rectified only. # J, K and Y voltages only. Dual frequency on C, no options. Code Omit I3N I6N Description Standard Response, No Switch Monitor Switch, & ort End Monitor Switch, & ort Start Note: Not CE or CS approved. C style with 001 and 009 spools only. Omit No Options J* Diode Surge Suppressor Z Rectified Coil * DC or C Rectified only. DIN coil must include plug with lights. DC tube standard. D111VW.indd, dd old: Designates ier I products and options. Non-old: Designates ier II products and options. hese products will have longer lead times. 213 Elyria, Ohio, US

212 Ordering Information Series D111VW Valve Variations 5* Signal Lights Standard Signal Lights Hirsch. (DIN with lug) 7** Manaplug rad Harrison (12x1) Micro with Lights 56** Manaplug (Mini) with Lights 1C** Manaplug (Mini) Single Sol. 5-pin, with Lights 1D** Manaplug (Micro) Single Sol. 5-pin, with Lights 1G** Manaplug (Mini) Single Sol. 5-pin, with Stroke djust & End and Lights 1H** Manaplug (Micro) Single Sol. 5-pin, with Stroke djust & End and Lights 1M** Manaplug Opposite Normal 1R Stroke djust & End with ilot Choke Meter In 3 ilot Choke Meter Out 3 ilot Choke Meter In 3C ilot ressure Reducer 3D Stroke djust End 3E Stroke djust End 3F Stroke djust & End 3G* ilot Choke Meter Out with Lights 3H* ilot Choke Meter In with Lights 3J* ilot ressure Reducer with Lights 3K ilot Choke Meter Out with Stroke djust & End 3L** ilot Choke Meter Out, Stroke djust & End with Lights and Manaplug rad Harrison Mini 3M ilot Choke Meter Out, ilot ressure Reducer, Stroke djust & End 3R ilot Choke Meter Out & ilot ressure Reducer 3S** Lights, Mini Manaplug, ilot Choke Meter Out 7Y** M12x1 Manaplug (4-pin), Special Wiring, and Lights * DESIN, plug-in conduit box, and DIN with plug styles only. ** Must have plug-in style conduit box. D111VW.indd, dd 214 Elyria, Ohio, US

213 echnical Information Solenoid Ratings Insulation System Class F llowable Deviation -15% to +10% for DC and C rectified coils from rated voltage -5% to +5% for C Coils rmature Wet pin type CS File Number LR60407 Environmental DC Solenoids meet NEM 4 and I67 Capability when properly wired and installed. Contact HVD for C coil applications. Series D111VW Explosion roof Solenoid Ratings* U.L. & CS (EU) Class I, Div 1 & 2, Groups C & D Class II, Div 1 & 2, Groups E, F & G s defined by the N.E.C. MSH (EO) Complies with 30CFR, art 18 EX (ED) Complies with EX requirements for: Exd, Group II; EN50014: mds. 1 & 2, EN50018: 2000 EX & CS/US (E) Complies with EX EN , EN Ex d IIC; CS/US Ex d IIC, Ex d IIC for Class I, Zone 1, UL1203, UL1604, CS E61241,1 Class II, Div 1 * llowable Voltage Deviation ±10%. Note that Explosion roof C coils are single frequency only. Code Voltage In Rush mps In Rush Holding mps Watts Resistance Voltage ower mperage 3MM Code Code D L 120 VDC N/ N/ 0.09 mps 10 W ohms D Omit 120 VDC N/ N/ 0.26 mps 30 W ohms G Omit 198 VDC N/ N/ 0.15 mps 30 W ohms J L 24 VDC N/ N/ 0.44 mps 10 W ohms J Omit 24 VDC N/ N/ 1.32 mps 30 W ohms K L 12 VDC N/ N/ 0.88 mps 10 W ohms K Omit 12 VDC N/ N/ 2.64 mps 30 W 4.32 ohms L L 6 VDC N/ N/ 1.67 mps 10 W 3.59 ohms L Omit 6 VDC N/ N/ 5.00 mps 30 W 1.20 ohms Q Omit 100 VC / 60 Hz 2.05 mps 170 V 0.77 mps 30 W ohms QD F 100 VC / 60 Hz 1.35 mps 135 V 0.41 mps 18 W ohms QD F 100 VC / 50 Hz 1.50 mps 150 V 0.57 mps 24 W ohms R F 24/60 VC, Low Watt 6.67 mps 160 V 2.20 mps 23 W 1.52 ohms Omit 240/60 VC 0.83 mps 199 V 0.30 mps 30 W ohms Omit 220/50 VC 0.87 mps 191 V 0.34 mps 30 W ohms F 240/60 VC, Low Watt 0.70 mps 168 V 0.22 mps 21 W ohms F 220/50 VC, Low Watt 0.75 mps 165 V 0.26 mps 23 W ohms U L 98 VDC N/ N/ 0.10 mps 10 W ohms U Omit 98 VDC N/ N/ 0.31 mps 30W ohms Y Omit 120/60 VC 1.7 mps 204 V 0.60 mps 30 W ohms Y Omit 110/50 VC 1.7 mps 187 V 0.68 mps 30 W ohms Y F 120/60 VC, Low Watt 1.40 mps 168 V 0.42 mps 21 W ohms Y F 110/50 VC, Low Watt 1.50 mps 165 V 0.50 mps 23 W ohms Z L 250 VDC N/ N/ 0.04 mps 10 W ohms Z Omit 250 VDC N/ N/ 0.13 mps 30 W ohms Explosion roof Solenoids R 24/60 VC 7.63 mps 183 V 2.85 mps 27 W 1.99 ohms 240/60 VC 0.76 mps 183 V 0.29 mps 27 W 1.34 ohms N 220/50 VC 0.77 mps 169 V 0.31 mps 27 W 1.38 ohms Y 120/60 VC 1.60 mps 192 V 0.58 mps 27 W ohms 110/50 VC 1.47 mps 162 V 0.57 mps 27 W ohms K 12 VDC N/ N/ 2.75 mps 33 W 4.36 ohms J 24 VDC N/ N/ 1.38 mps 33 W ohms "E" Explosion roof Solenoids K 12 VDC N/ N/ 1.00 mps 12 W ohms J 24 VDC N/ N/ 1.00 mps 13 W ohms Y 120/60-50 VC N/ N/ 0.16 mps 17 W ohms D111VW.indd, dd 215 Elyria, Ohio, US

214 Specifications Series D111VW General Design Directional Spool Valve ctuation Solenoid Size NG32 Mounting Interface DIN / ISO 4401 / NF D10 / CEO R 121-H Mounting osition Unrestricted, preferably horizontal mbient emperature [ C] [ C] MF D Value [years] 75 Hydraulic ; (-13 F F) (without inductive position control) ; (+32 F F) (with inductive position control) ilot drain internal:,,, X 350 ar (5075 SI) Maximum Operating ressure, Y 102 ar (1500 SI) C only, 207 ar (3000 SI) DC/C optional ilot drain external:,,,, X 350 ar (5075 SI) Y 102 ar (1500 SI) C only, 207 ar (3000 SI) DC/C optional Fluid Hydraulic oil in accordance with DIN / Fluid emperature [ C] ; (-13 F F) Viscosity ermitted [cst]/[mm²/s] ( SSU) Recommended [cst]/[mm²/s] ( SSU) Filtration ISO 4406 (1999); 18/16/13 (meet NS 1638: 7) Flow Maximum 2000 LM (529.1 GM) Leakage at 350 ar (per flow path) [ml/min] up to 5000 (1.32 GM) depending on spool Minimum ilot Supply ressure 5 ar (73 SI) Static / Dynamic Step Response at 95% Energized De-energized DC Solenoids ilot ressure 50 ar [ms] ar [ms] ar [ms] ar [ms] C Solenoids ilot ressure [ms] 50 ar [ms] ar [ms] ar [ms] ar [ms] D111VW.indd, dd 216 Elyria, Ohio, US

215 Electrical Specifications Series D111VW osition Control M12x1 rotection Class I 65 in accordance with EN (plugged and mounted) mbient emperature [ C] ; (+32 F F) Supply Voltage / Ripple [V] ±10% Current Consumption without Load [m] 30 Max. Output Current per Channel, Ohmic [m] 400 Min. Output Load per Channel, Ohmic [kohm] 100 Max. Output Drop at 0.2 [V] 1.1 Max. Output Drop at 0.4 [V] 1.6 EMC EN / EN Max. olerance mbient Field Strength [/m] <1200 Min. Distance to Next C Solenoid [m] >0.1 Interface M12x1 per IEC Wiring Minimum [mm²] 5 x 0.25 brad shield recommended Wiring Length Maximum [m] 50 (164 ft.) recommended M12 in ssignment 1 + Supply V 2 Out : normally closed 3 0V 4 Out : normally open 5 Earth ground Definitions Start position monitored: he valve is de-energized. he inductive switch gives a signal at the moment (below 15% spool stroke) when the spool leaves the spring offset position. End position monitored: he inductive switch gives a signal before the end position is reached. (above 85% spool stroke). Delivery includes plug M12 x 1 (part no ). D111VW.indd, dd 217 Elyria, Ohio, US

216 echnical Information Series D111VW ilot Oil Inlet (Supply) and Outlet (Drain) ll orifice sizes for standard valves Dimensions Inch equivalents for millimeter dimensions are shown in (**) * lease add for each sandwich plate +40mm (1.58") (pressure reducing valve, pilot choke meter-in/-out). Surface Finish Seal K386 6x M20x90 DIN Nm (381.3 lb.-ft.) Nitrile: SK-D111VW-N-91 Fluorocarbon: SK-D111VW-V-91 he space necessary to remove the plug per DIN 43650, design type F is at least 15 mm (0.59 in.). he torque for the screw M3 of the plug has to be 0.5 Nm (3.7 lb.-ft. ) to 0.6 Nm (4.4 lb.-ft). D111VW.indd, dd 218 Elyria, Ohio, US

217 ccessories Manaplug (Options 56 & 1C) Interface rad Harrison lug 3-in for Single Solenoid 5-in for Double Solenoid Ground Wire #1 (Green) Series D111VW Micro Connector Options (7 & 1D) Solenoid (Negative) Wire #3 (Red/lack) Solenoid (ositive) Wire #2 (Red/White) 3-in Manaplug (Mini) with Lights Single Solenoid Valves Installed Opposite Side of Solenoid ins are as seen on valve (male pin connectors) Conduit ox Option C No Wiring Options vailable Signal Lights (Option 5) lug-in Only LED Interface Meets Nema 4/I67 Hirschmann lug with Lights (Option 5) ISO 4400/DIN Form in #2 (ositive) D111VW.indd, dd Face View of lug in #3 (Ground) in #1 (Negative) DESIN Connector (Option D) M12 pin assignment Standard 1 = Not used 2 = Not used 3 = 0V 4 = Signal (24 V) 5 = Earth Ground ins are as seen on valve (male pin connectors) DESIN design in 1 and 2 connected Elyria, Ohio, US

218 Catalog HY /US Installation Information FOR MXIMUM VLVE RELIILIY, DHERE O HE FOLLOWING INSLLION INFORMION. he following is important installation information which applies to all directional control valves described in this catalog. Mounting osition Detent Horizontal Spring Offset Unrestricted Spring Centered Unrestricted Fluid Recommendations remium quality hydraulic oil with a viscosity range between cst ( SSU) t 38 C (100 F) is recommended. he absolute operating viscosity range is from cst ( SSU). Oil should have maximum anti-wear properties and rust and oxidation treatment. Series D111VW Silting Silting can cause any sliding spool valve to stick and not spring return if held under pressure for long periods of time. he valve should be cycled periodically to prevent sticking. Special Installations Consult your arker representative for any application requiring the following: ressure above rating. Fluid other than those specified. Oil temperature above 71.1 C (160 F). Flow path other than normal. Mounting atterns Series NF Size D111V*, D10 D10 1-1/4 Fluids and Seals Valves using synthetic, fire-resistant fluids require special seals. When phosphate esters or its blends are used, FLUOROCRON seals are required. Waterglycol, water-in-oil emulsions and petroleum oil may be used with SNDRD seals. orque Specifications he recommended torque values for the bolts which mount the valve to the manifold or subplate are as follows: Nm (300 ft-lbs). Filtration For maximum valve and system component life, the system should be protected from contamination at a level not to exceed 125 particles greater than 10 microns per milliliter of fluid (SE class 4/ISO 16/13). D111VW.indd, dd 220 Elyria, Ohio, US

219 Installation Information Series D111VW ank and Drain Line Surges If several valves are piped with a common tank or drain line, flow surges in the line may cause an unexpected spool shift. Detent style valves are most susceptible to this. Separate tank and drain lines should be piped in installations where line surges are expected. Electrical Characteristics (Detented Spool) Only a momentary energizing of the solenoid is necessary to shift and hold a detented spool. Minimum duration of the signal is 0.1 seconds for DC voltages. For C voltages the response time is 0.06 seconds. Spool position will be held provided the spool centerline is in a horizontal plane, and not shock or vibration is present to displace the spool. Electrical Failure or Loss of ilot ressure Should electric power fail or loss of pilot pressure occur, spring offset and spring centered valves will shift to the spring held position. Detented valves will stay in the last position held before power failure. If main flow does not fail or stop at the same time power fails, machine actuators may continue to function in an undesirable manner or sequence. ilot/drain Characteristics ilot ressure: 5 to 345 ar (73 to 5000 SI) External: n oil source sufficient to maintain minimum pilot pressure must be connected to the X port of the main body. When using the external pilot variation, a 1/16" pipe plug must be present in the main body pilot passage. (For details see echnical pages.) his plug will be furnished in valves ordered with pilot code 2 or 5. Internal: Flow is internally ported from the pressure port of the main valve body to the port of the pilot valve. he pressure developed at the port of the pilot valve must be 5 ar (73 SI) minimum at all times. ilot Valve Drain: Maximum pressure 102 ar (1500 SI) C standard, 207 ar (3000 SI) C optional/dc standard. External: When using an external drain, a 10 x 24 x 0.31 long set screw must be present in the main body drain passage. (For details see echnical pages.) his plug will be furnished in valves ordered with drain code 1 or 2. Drain flow from the pilot valve is at the Y port of the main body and must be piped directly to tank. Maximum drain line pressure is 102 ar (1500 SI) C standard, 207 ar (3000 SI) C optional/dc standard. ny drain line back pressure is additive to the pilot pressure requirement. Internal: Drain flow from the pilot valve is internally connected to the main valve tank port. ank and drain pressure are then identical so tank line pressure should not exceed 102 ar (1500 SI) C standard, 207 ar (3000 SI) DC standard/c optional. ny tank line back pressure is also additive to the pilot pressure requirement. If flow surges (a cause of pressure surges) are anticipated in the tank line, an external drain variation is recommended. he Y port in the subplate must be plugged when using an internal drain. Style No Solenoid/Operator Solenoid/Operator Solenoid/Operator Energized Energized Energized Spring Offset and and C Spring Centered Centered and and D Detented Last osition Held and and E Spring Centered Centered and F Spring Offset, Shift to Center and Centered H Spring Offset and and K Spring Centered Centered and M Spring Offset, Shift to Center and Centered D111VW.indd, dd 221 Elyria, Ohio, US

220 Catalog HY /US Installation Information Subplate Mounting NF D10, CEO 10 & NG 32 Recommended Mounting Surface Surface must be flat within.102 mm ( inch).i.r and smooth within micro-meters (32 micro-inch). orque bolts to Nm (300 ft-lbs). Mounting osition Valve ype Detent (Solenoid) Spring Offset Spring Centered Mounting osition Horizontal Unrestricted Unrestricted Series D111VW For maximum valve reliability, adhere to the following installation information. Mounting attern NF D10, CEO 10 & NG32 Inch equivalents for millimeter dimensions are shown in (**) (7.84) Min (6.26) (5.13) (4.88) 79.4 (3.13) 44.5 (1.75) (7.51) (5.82) 82.6 (3.25) 41.3 (1.63) 35.0 (1.38) (6.63) (4.50) 76.2 (3.00) (9.06) Min. M20 x 33.3 (3/4-10 UNC-2 x 1.31) Min. hd. Dp. 6 Holes 0.28 (0.011) (0.441) Max. 3 Holes 0.56 (0.022) (1.250) Max. 4 Holes 7.32/6.91 x 8 Min. Dp. (0.288/0.272 x.31) 2 Holes 0.28 (0.011) 0.56 (0.022) (0.75) R. Max. yp. 4 laces D111VW.indd, dd 222 Elyria, Ohio, US

221 echnical Information Sequence Valves Series R4S General Description Series R4S pilot operated sequence valves enable a hydraulic system to operate in a pressure sequence. When the system pressure reaches the setting pressure the valve opens and permits flow to the secondary sub-system. D Features ilot-operated sequence valve. 3 pressure ranges. 3 adjustment modes: Hand knob corn nut with lead seal Key lock Ordering Information R 4 S ressure Valve Interface Relief Function Size 03 NG10 06 NG25 10 NG32 Maximum ody ressure Mounting 350 ar (5075 SI) ressure Range 1 up to 105 ar (1523 SI) 3 up to 210 ar (3045 SI) 5 up to 350 ar (5075 SI) djustment External Drain from Subplate Design Series Seal 1 Nitrile 5 Fluorocarbon Code Interface Subplate 4 Mounting ISO Hand Knob 32mm dia. Std. 3 corn Nut with Lead Seal 4 Key Lock Weight: R4S03: R4S06: R4S10: 2.7 kg (6.0 lbs.) 4.5 kg (9.0 lbs.) 6.0 kg (13.2 lbs.) R4S.indd, dd D36 Elyria, Ohio, US

222 echnical Information Sequence Valves Series R4S Specifications General Size NG10 NG25 NG32 Interface Subplate mounting acc. ISO 5781 Mounting osition s desired, horizontal mounting preferred mbient emperature -20 C to +80 C (-4 F to +176 F) Hydraulic Operating ressure orts, and X up to 350 ar (5075 SI), ort Y: depressurized ressure Range up to 105, 210, 350 ar (1523, 3045, 5075 SI) Nominal 150 LM 350 LM 650 LM Flow (39.7 GM) (92.6 GM) (172.0 GM) ressure Fluid Hydraulic oil according to DIN Viscosity Recommended 30 to 50 cst / mm²/s (139 to 232 SSU) Maximum 20 to 380 cst / mm²/s (93 to 1761 SSU) ressure Fluid emperature Recommended + 30 C to +50 C (+86 F to +122 F) Maximum -20 C to +70 (-4 F to +158 F) Filtration ISO 4406 (1999), 18/16/13 D erformance Curves ypical pressure curves at closing point 1 = setting pressure 2 = operating pressure Note: ime and pressure underlap depend on the characteristics of a specific system. R4S.indd, dd D37 Elyria, Ohio, US

223 Dimensions Sequence Valves Series R4S D R4S.indd, dd D38 Elyria, Ohio, US

224 Dimensions Sequence Valves Series R4S Inch equivalents for millimeter dimensions are shown in (**) NG ISO-code x1 x2 x3 x4 x5 x6 x7 y1 y2 y3 y4 y5 y (1.69) (1.41) (0.85) (0.28) (0.85) (1.25) (2.63) (2.31) (1.31) (0.31) (2.37) (1.94) (1.56) (0.44) (0.81) (1.75) (3.13) (2.87) (1.56) (0.25) (3.31) (2.66) (2.34) (1.66) (0.66) (0.97) (2.47) (3.81) (3.65) (1.91) (0.15) olerance at X and Y pin holes and screw holes ±0.1, at port holes ±0.2. NG ISO-code 1 2 H1 H2 H3 H4 H5 H6 L1 L2 L3 L4 L5 L (3.44) (1.31) (3.27) (0.83) (2.46) (1.14) (3.73) (5.55) (7.13) (4.13) (1.56) (4.31) (1.14) (3.50) (1.37) (4.99) (5.55) (7.13) (4.72) (1.91) (4.72) (1.14) (3.92) (1.20) (5.68) (5.55) (7.13) D NG ISO-code d1max d2max d3 t3 d4 t4 d5 d M (0.59) (0.28) (0.28) (0.31) (0.63) (0.43) (0.67) M (0.92) (0.28) (0.28) (0.31) (0.71) (0.43) (0.67) M (1.26) (0.28) (0.28) (0.31) (0.79) (0.43) (0.67) Seal NG ISO-code olt Kit Nitrile Fluorocarbon Surface Finish K505 4xM10 x 35-DIN Nm S S (46.5 lb.-ft.) ±15% K485 4xM10 x 45-DIN Nm S S (46.5 lb.-ft.) ±15% K506 6xM10 x 45-DIN Nm S S (46.5 lb.-ft.) ±15% NG ISO-code Subplate Size S3M6910, = 3/4" S x, y = 1/4" S S6M8910, = 1" S x, y = 1/4" S S10M12910, = 1 1/2" S x, y = 1/4" S R4S.indd, dd D39 Elyria, Ohio, US

225 echnical Information Sequence Valves Series R5S General Description Series R5S pilot operated sequence valves have a similar design to the subplate mounted R4S series. he SE flanges allow to mount the valve directly on the inlet flanges of actuators or outlet flanges of pumps to achieve a very compact design. Features ilot operated with manual adjustment. 3-port body with SE61 flange. 3 sizes (SE 3/4", 1", 1-1/4"). 3 pressure stages: 2 adjustment modes: Hand knob corn nut with lead seal D Ordering Information R5S 3 6 ressure Sequence Valve Size 06 SE 3/4" 08 SE 1" 10 SE 1-1/4" SE 61 Interface 3-ort ody Y1, M = SE 4 ressure Range 1 up to 105 ar (1523 SI) 3 up to 210 ar (3045 SI) 5 up to 350 ar (5075 ar) djustment External Drain from Y1 ort Design Series Seal 1 Nitrile 5 Fluorocarbon Options Check with Factory Code Size Max. ressure ar (4060 SI) 5 06/ ar (5075 SI) 1 Hand Knob 3 corn Nut with Lead Seal 4 Key Lock Weight: R5S06 R5S08 R5S kg (7.9 lbs.) 4.6 kg (10.1 lbs.) 5.2 kg (11.5 lbs.) R5S.indd, dd D65 Elyria, Ohio, US

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style Introduction pplication hydraulic directional control valves are high performance, direct operated 4-way valves. hey are available in 2 or 3-position styles. hey are manifold mounted valves, which conform

More information

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style Catalog HY14-2500/US Introduction pplication hydraulic directional control valves are high performance, direct operated 4-way valves. hey are available in 2 or 3-position styles. hey are manifold mounted

More information

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style Introduction pplication hydraulic directional control valves are high performance, direct operated 4-way valves. hey are available in 2 or 3-position styles. hey are manifold mounted valves, which conform

More information

Directional Control Valves. General Description. Operation. Features

Directional Control Valves. General Description. Operation. Features echnical Information General Description W directional control valves are 5-chamber, pilot operated, solenoid controlled valves, hey are available in 2 or 3-position styles. hese valves are manifold or

More information

Directional Control Valves Series D81V. General Description. Operation. Features. Specifications

Directional Control Valves Series D81V. General Description. Operation. Features. Specifications echnical Information General Description W directional control valves are 5-chamber, pilot operated, solenoid controlled valves. hey are available in 2 or 3-position styles. hese valves are manifold or

More information

Directional Control Valves. Features. Application. Operation

Directional Control Valves. Features. Application. Operation Introduction pplication hydraulic directional control valves are high performance, solenoid controlled, pilot operated, 2-stage, 4-way valves. hey are available in 2 or 3-position styles and are manifold

More information

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US LH Industrial Hydraulic Valves Directional Control, ressure Control, Sandwich, Subplates & Manifolds, ccessories Catalog HY14-2500/US Industrial Hydraulic Valves LH WRNING USER RESONSIILIY FILURE OR IMROER

More information

Hydraulics 1. Directional Control Valves Series D1M. Features. Application. Operation. D1MW Solenoid Operated Free Lead Wire

Hydraulics 1. Directional Control Valves Series D1M. Features. Application. Operation. D1MW Solenoid Operated Free Lead Wire ulletin 2544-1/US Introduction pplication arker D1M Series hydraulic directional control valves are high performance, direct operated 4-way valves. hey are available in 2 or 3 position styles. hey are

More information

Directional Control Valves

Directional Control Valves echnical Information General Description he D1VW Series directional control valves are highperformance, 4-chamber, direct operated, wet armature solenoid controlled, 3 or 4-way valves. hey are available

More information

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US LH Industrial Hydraulic Valves Directional Control, ressure Control, Sandwich, Subplates & Manifolds, ccessories Catalog HY14-2500/US echnical Information General Description Series D1VW directional control

More information

Directional Control Valves. Application. Features. Operation. D3W Solenoid Operated Conduit Cavity Style. D3W Solenoid Operated Hirschmann (DIN) Style

Directional Control Valves. Application. Features. Operation. D3W Solenoid Operated Conduit Cavity Style. D3W Solenoid Operated Hirschmann (DIN) Style Catalog HY14-2500/US Introduction pplication Series D3 hydraulic directional control valves are high performance, direct operated 4-way valves, available in 2 or 3-position. hey are manifold mounted which

More information

Directional Control Valves. General Description. Operation. Features

Directional Control Valves. General Description. Operation. Features echnical Information Series D61VW General Series D61VW directional control valves are 5-chamber, pilot operated, solenoid controlled valves, hey are available in 2 or 3-position styles. hese valves are

More information

Directional Control Valves. Application. Features. Operation

Directional Control Valves. Application. Features. Operation Catalog HY14-2502/US Introduction pplication Series D81 hydraulic directional control valves are high performance, solenoid controlled, pilot operated, 2-stage, 4-way valves. hey are available in 2 or

More information

Directional Control Valves. Application. Features. Operation.

Directional Control Valves. Application. Features. Operation. Catalog HY14-2500/US Introduction pplication Series D101 hydraulic directional control valves are high performance, solenoid controlled, pilot operated, 2-stage, 4-way valves. hey are available in 2 or

More information

Directional Control Valves. General Description. Operation. Features

Directional Control Valves. General Description. Operation. Features echnical Information Series D101VW General Series D101VW directional control valves are 5-chamber, pilot operated, solenoid controlled valves. hey are available in 2 or 3-position styles. hese valves are

More information

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US LH SECION Industrial Hydraulic Valves Directional Control, ressure Control, Sandwich, Subplates & Manifolds, ccessories echnical Information General Description Series D61VW directional control valves

More information

Directional Control Valves. Application. Features. Operation

Directional Control Valves. Application. Features. Operation Catalog HY14-2500/US Introduction pplication Series D81 hydraulic directional control valves are high performance, solenoid controlled, pilot operated, 2-stage, 4-way valves. hey are available in 2 or

More information

Directional Control Valves. Features. Application. Operation

Directional Control Valves. Features. Application. Operation Catalog HY14-2502/US Introduction pplication Series D31 hydraulic directional control valves are high performance, solenoid controlled, pilot operated, 2-stage 4-way valves. hey are available in 2 or 3-

More information

Série D3 Válvula Direcional CETOP 5 e NG 10. Catálogo HY /US

Série D3 Válvula Direcional CETOP 5 e NG 10. Catálogo HY /US Série D3 Válvula Direcional CETOP 5 e NG 10 Catálogo HY14-2502/US Catalog HY14-2502/US Introduction pplication Series D3 hydraulic directional control valves are high performance, direct operated 4-way

More information

Operation. D3W Solenoid Operated Conduit Box Style. D3W Solenoid Operated Hirschmann (DIN) Style

Operation. D3W Solenoid Operated Conduit Box Style. D3W Solenoid Operated Hirschmann (DIN) Style Catalog HY14-252/US Introduction pplication arker D3 Series hydraulic directional control valves are high performance, direct operated 4-way valves, available in 2 or 3 position. hey are manifold mounted

More information

Directional Control Valves Series D111VW. General Description. Features. Performance Curves

Directional Control Valves Series D111VW. General Description. Features. Performance Curves Technical Information General valves are piloted by a D1VW valve. The valves can be ordered with position control. The minimum pilot pressure must be ensured for all operating conditions of the directional

More information

Directional Control Valves. Features. Application. Operation

Directional Control Valves. Features. Application. Operation Introduction pplication Series D31 hydraulic directional control valves are high performance, solenoid controlled, pilot operated, 2-stage, 4-way valves. hey are available in 2 or 3-position styles and

More information

Directional Control Valves. General Description. Features. Specifications

Directional Control Valves. General Description. Features. Specifications Technical Information General Description directional control valves are high-performance, 4-chamber, direct operated, wet armature, solenoid controlled, 3 or 4-way valves. They are available in 2 or 3-position

More information

Bulletin HY M6/US Service Bulletin. Series D1VW, H Style 91 Design. Effective: May 1, Directional Control Valves

Bulletin HY M6/US Service Bulletin. Series D1VW, H Style 91 Design. Effective: May 1, Directional Control Valves Service Bulletin 91 Design Effective: May 1, 2007 FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This

More information

Bulletin HY M2/US Service Bulletin. Series D1VW, C Style 91 Design. Effective: May 1, Directional Control Valves

Bulletin HY M2/US Service Bulletin. Series D1VW, C Style 91 Design. Effective: May 1, Directional Control Valves Service Bulletin 91 Design Effective: May 1, 2007 FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This

More information

Direct Operated Proportional DC Valves

Direct Operated Proportional DC Valves echnical Information Direct Operated roportional DC Valves Series D1F and D3F General Series D1F and D3F directional control valves of nominal sizes NG6 (CEO 3) and NG10 (CEO 5) respectively, provide variable

More information

Bankable Control Valves

Bankable Control Valves Hydraulics ankable Control Valves Catalog 3123/US Catalog 3123/US Contents ankable Control Valves WRNING FILURE OR IMROER SELECION OR IMROER USE OF HE RODUCS ND/OR SYSEMS DESCRIED HEREIN OR RELED IEMS

More information

Hydraulic Power Units D, H, V-Pak and V-Pak Low Profile Series

Hydraulic Power Units D, H, V-Pak and V-Pak Low Profile Series aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Hydraulic ower Units D, H, V-ak and V-ak Low rofile Series HY28-2661-CD/US

More information

Chapter 2: Directional Control Valves

Chapter 2: Directional Control Valves Contents Chapter : Directional Control Valves Series Description Direct operated Pilot operated Page DIN / ISO 06 10 16 5 3 10 16 5 3 Seat valves, electrically operated D1SE - Spool valves, electrically

More information

Directional Controls

Directional Controls VICKERS Directional Controls Solenoid Operated Directional Control Valves NF D05, ISO-4401-05 DG4S*-01**-5* ir Gap ype Revised 8/97 671 able of Contents DG4S*-01 Model Code..................................................................................

More information

Pilot-Operated Directional Control Valves Series D3 - D11

Pilot-Operated Directional Control Valves Series D3 - D11 Catalogue HY11-500/UK Characteristics The D31, D41, D81, D91 and D111 are electrical controlled 4/3 or 4/ way directional control valves. The valves are pilot-operated by an NG6 valve. Pressure and flow

More information

Directional Control Valve

Directional Control Valve Characteristics The NG6 directional control valve series D1VW provides high functional limits up to 8 l/min in combination with a very low, energy-saving pressure drop. wide variety of spool options allows

More information

Directional Controls

Directional Controls Vickers Directional Controls Mechanical ctuators Directional Control Valves Directional Control Valves 310 bar (4500 psi) Flows to 114 l/min (30 USgpm) NF D05, ISO-4401-05 DG1V4-01**-10 Knob Operated DG17V4-01**-10

More information

Bar 35 PSI 500. Pressure Drop L/M GPM. Flow

Bar 35 PSI 500. Pressure Drop L/M GPM. Flow NF D3 O E R I N G N D E C H N I C L D RINGS Maximum Flow... See Chart Maximum Operating ressure (, and orts)... 3 ar ( SI) Maximum ank Line ressure... 13 ar (1 SI) Mounting attern... ISO 441--3-4-, NF-D3

More information

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW Characteristics The D31, D41, D81, D91 and D111 are electrically controlled 4/3 or 4/ way directional control valves. The valves are pilot operated by an NG6 valve. Pressure and flow of the pilot oil have

More information

Directional Control Valve Series D1VW

Directional Control Valve Series D1VW Characteristics The NG6 directional control valve series D1VW provides high functional limits up to 8 l/min in combination with a very low, energy-saving pressure drop. A wide variety of spool options

More information

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW Characteristics The pilot operated valves are available in 4 sizes: D31DW NG10 (standard) D31NW NG10 (high flow) D41VW NG16 D81VW NG5 (for port diameter up to 6 mm) D91VW NG5 (for port diameter up to 3

More information

High Pressure, Subplate Mounted Directional Control Valves

High Pressure, Subplate Mounted Directional Control Valves ENGINEERING SECIFICIONS High ressure, Subplate Mounted Directional Control Valves MODEL H05 5 gpm (19 L/min) nominal 8000 psi (560 bar) Sliding-spool H05 valves provide true four-way control in a simple

More information

Directional Controls

Directional Controls Vickers Directional Controls ilot Operated Directional Valves DG3V-10 Hydraulic ilot Operated; 1100 l/min (290 USgpm) 350 bar (5000 psi) DG5V-10 Solenoid ilot Operated; 1100 l/min (290 USgpm) 350 bar (5000

More information

Directional Control Valves. General Description. Features. Specifications

Directional Control Valves. General Description. Features. Specifications echnicl Informtion Generl Description directionl control vlves re high performnce, 5-chmer, direct operted, wet rmture, solenoid controlled, 3 or 4-wy vlves. hey re ville in 2 or 3-position nd conform

More information

Manapak Sandwich Valves. General Description

Manapak Sandwich Valves. General Description echnical Information Series RM General Description RM Series relief valves limit system pressure by opening to tank when system pressure reaches the valve setting. With D3 size, they can also be configured

More information

Explosion-Proof Valves. According to Directive 94/9/EC (ATEX) and IECEx Requirements

Explosion-Proof Valves. According to Directive 94/9/EC (ATEX) and IECEx Requirements Explosion-Proof Valves ccording to Directive 94/9/EC (EX) and IECEx Requirements WRNING USER RESPONSIILIY FILURE OR IMPROPER SELECION OR IMPROPER USE OF HE PRODUCS DESCRIED HEREIN OR RELED IEMS CN CUSE

More information

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX: SECIFICIONS D05H attern Directional Control Valves lso refer to "Directional Valve Features, Selection and Operating Recommendations" (dynexdcvoperating.pdf) CONC INFORMION US Headquarters 770 Capitol

More information

Sandwich Valves Series CP

Sandwich Valves Series CP Technical Information General Description. pilot operated check valves are designed for maximum flow rates. The valves are typically used in combination with spool type directional control valves to ensure

More information

High Pressure, Subplate Mounted Directional Control Valves

High Pressure, Subplate Mounted Directional Control Valves ENGINEERING SECIFICIONS High ressure, Subplate Mounted Directional Control Valves MODEL H03 5 gpm (19 L/min) nominal 10 000 psi (700 bar) H03 valves are rated for 5 gpm (19 L/min) nominal flow at pressures

More information

RA / Accumulator unloading valve, pilot operated, Model DA 6 V.., series 4X. Ordering details DA 6 V 4X. Preferred models 1/8.

RA / Accumulator unloading valve, pilot operated, Model DA 6 V.., series 4X. Ordering details DA 6 V 4X. Preferred models 1/8. R 26 404/06.9 ccumulator unloading valve, pilot operated, Model D 6 V.., series 4X Size 6 up to 4500 SI (315 bar) up to.00 GM (30 L/min) R 26 404/04.9 Features: For subplate mounting: porting pattern to

More information

Directional Control Valve Series D3W Soft Shift

Directional Control Valve Series D3W Soft Shift Characteristics The D3W is a 3-chamber, electrically controlled 4/3 or 4/ way directional control valve. It is activated directly by solenoids with screwed in wet pin armature. The soft shifting of this

More information

Directional Control Valve Series 4D01 (DENISON)

Directional Control Valve Series 4D01 (DENISON) Characteristics The Denison series 4D01 is a solenoid operated directional control valve size NG06 in -chamber design. It is direct operated by wet pin solenoids. The 4D01 is available with a Soft Shift

More information

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX: DIRECIONL VLVE OERION Directional Valve Features, Selection and Operating Recommendations CONC INFORMION US Headquarters Dynex/Rivett Inc. 770 Capitol Drive ewaukee, WI 3072 U.S.. el: 262-69-2222 FX: 262-69-032

More information

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US Industrial Hydraulic Valves irectional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories Catalog HY14-25/US Industrial Hydraulic Valves WARNING USER RESPONSIBILITY FAILURE OR IMPROPER

More information

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX: SECIFICIONS D0H attern Directional Control Valves lso refer to "Directional Valve Features, Selection and Operating Recommendations" (dynexdcvoperating.pdf) CONC INFORMION US Headquarters 770 Capitol Drive

More information

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1. Solenoid Valves Poppet and Spool type solenoid actuated valves for applications up to 5 bar (5 psi) and 7 L/min (6 USgpm) n Eaton Brand ETON Screw-In Cartridge Valves E-VLSC-MC-E November 9 -. Solenoid

More information

D07 & D08. Series 35 Solenoid Valves D07 D Friendship Drive, Magnolia, TX Tel.: Fax:

D07 & D08. Series 35 Solenoid Valves D07 D Friendship Drive, Magnolia, TX Tel.: Fax: GENERL FEURES SNDRD FEURES High ressure/ High Flow: 65 gpm/ psi ilot Operation: Main spool controlled by D0 solenoid pilot valve- allows for addition of modular valves to reduce shifting shock. Oil Immersed,

More information

Monobloc and Sectional Directional Control Valves

Monobloc and Sectional Directional Control Valves Monobloc and Sectional irectional Control Valves 200 - - 991210 - - 03/09.2015 1/220 8 Sectional directional control valves HS11 8 valves... p.101 Contents 8.1 General specification 101 8.2 imensional

More information

Directional Control Valves

Directional Control Valves Frequently sked Questions N-1 Frequently sked Questions What is the function of a directional control valve? directional control valve is the extend and retract control for your hydraulic cylinders. It

More information

DFE10. solenoid control monoblock valve. Ordering codes. Description example : Diverter valve DFE10/3 A 18 ES - W VDC - SAE - <CVN>

DFE10. solenoid control monoblock valve. Ordering codes. Description example : Diverter valve DFE10/3 A 18 ES - W VDC - SAE - <CVN> DFE1 Ordering codes Description example : Diverter valve DFE1/3 18 ES - W 22-12VDC - SE - 1. 4. 5. 3. 5. 2. Valve is supplied painted as standard, with one coat of rimer black antirust paint II 5.

More information

Directional Controls

Directional Controls VICKERS Directional Controls DG3V-7, 20 Series, ilot Operated DG5V-7, 40 Series, Solenoid Controlled, ilot Operated ISO 440 Size 07 ypical Section DG5V-7-2C Spring-Centered Valve Example Basic Characteristics

More information

EManually Operated Directional Valves

EManually Operated Directional Valves DIRECIONL CONROLS hese valves may be used to manually shift the spool position and change the direction of oil flow. hreaded Connections Sub-late Mounting Specifications DM--C - DM--D - DM--D - DM-- -

More information

Directional Control Valve Series D3W (Parker), 4D02 (Denison)

Directional Control Valve Series D3W (Parker), 4D02 (Denison) Characteristics Series D3W (Parker), 4D0 (Denison) The direct operated directional control valve size NG10 is available with both Parker (series D3W) and Denison (series 4D0) model codes. Both series are

More information

4/2- and 4/3-Way Proportional Directional Control Valve Direct Operated, Model 4 WRA (Series 1X) PSI (315 bar) H/A 1768

4/2- and 4/3-Way Proportional Directional Control Valve Direct Operated, Model 4 WRA (Series 1X) PSI (315 bar) H/A 1768 /- and /-Way roptional Directional Control Valve Direct Operated, Model WR (Series X) Size 6 and... 6 SI ( bar).... GM (9 L/min) R 9 /6.98 R 9 /6.98 Replaces:.9 Characteristics: F the open loop control

More information

"G" SERIES SHOCKLESS TYPE SOLENOID OPERATED DIRECTIONAL VALVES G-DSG-01/03 (1/8, 3/8) "G" SERIES SHOCKLESS TYPE

G SERIES SHOCKLESS TYPE SOLENOID OPERATED DIRECTIONAL VALVES G-DSG-01/03 (1/8, 3/8) G SERIES SHOCKLESS TYPE "G" SRIS SHOCKLSS Y NOID ORD DIRCIL VLVS G-DSG-1/3 (1/, 3/) "G" SRIS SHOCKLSS Y NOID CROLLD ILO ORD DIRCIL VLVS G-DSHG-/ (1/, 3/) Mounting Up to 5 Ma (33 SI), 5 L /m in (.1 U.S.GM) ub. C-5 DIRCIL CROLS

More information

NG06. General Size NG6 NG10 Design

NG06. General Size NG6 NG10 Design Catalog HY14-255/US Series VY*K General Series VY*K pilot operated sequence valves feature proportional adjustment and an external drain. The external drain allows application as both a sequence valve

More information

Monobloc and Sectional Directional Control Valves

Monobloc and Sectional Directional Control Valves Monobloc and Sectional Directional Control Valves motion and progress 200 991210 03 / 10.04 1/220 HDS11 8 Sectional directional control valves HDS11 8 Standard valves................................................................

More information

Monobloc and Sectional Directional Control Valves

Monobloc and Sectional Directional Control Valves Monobloc and Sectional Directional Control Valves 200--991210-N-03/09.2015 03 / 10.04 1/220 11 Sectional directional control valves HDS30 Contents 11.1 General specifications 197 11.2 Dimensional data

More information

Flow Control Valves Check Valves Gauge Control Valves. Colorflow Valves

Flow Control Valves Check Valves Gauge Control Valves. Colorflow Valves Check Valves Gauge Control Valves Colorflow Valves Colorflow and Ball Valves Industrial Flow Control, Check, Gauge Control Catalog HY14-3300/US Colorflow and Ball Valves Fully guided poppets are used on

More information

Pilot Operated Directional Valves

Pilot Operated Directional Valves ilot Operated Directional Valves Catalog DG3V-10 Hydraulic ilot Operated; 1100 l/min (290 USgpm) 350 bar (5000 psi) DG5V-10 Solenoid ilot Operated; 1100 l/min (290 USgpm) 350 bar (5000 psi) NF D10, ISO-4401-10,

More information

Solenoid valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

Solenoid valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) Hydraulic Screw-in Cartridge Valves (SiCV) Solenoid valves Poppet and Spool type solenoid actuated valves for applications up to 5 bar (5 psi) and 7 L/min (6 USgpm) Solenoid valves SOLENOID VLVES...- SV5-8-C/CM

More information

High Response Type Proportional Electro-Hydraulic Directional and Flow Control Valves

High Response Type Proportional Electro-Hydraulic Directional and Flow Control Valves igh Response ype roportional Electro-ydraulic s igh response, high precision and high reliability are achieved by a combination of compact and powerful solenoid and spool-position-detection LVD. Direct

More information

Proportional Pressure Reducing Valve Series D1FV

Proportional Pressure Reducing Valve Series D1FV Characteristics roportional ressure Reducing Valve Series D1FV he proportional pressure reducing valves series D1FV are available with and without onboard electronics (OE). D1FV OE he digital onboard electronics

More information

4/3 and 4/2 on-off directional valve elements D8_5 with or (EDD-XZ) without secondary relief valves and with or without LS connections D8_5 (EDD-XZ)

4/3 and 4/2 on-off directional valve elements D8_5 with or (EDD-XZ) without secondary relief valves and with or without LS connections D8_5 (EDD-XZ) 4/3 and 4/2 on-off directional valve elements D8_5 with or (EDD-XZ) without secondary relief valves and with or without LS connections D8_5 (EDD-XZ) RE 18301-12 Edition: 02.2016 Replaces: 07.12 07.2012

More information

3/2 and 4/2 directional seat valves with solenoid actuation

3/2 and 4/2 directional seat valves with solenoid actuation 1/16 3/ and 4/ directional seat valves with solenoid actuation RE 047-XH-B/01.10 Replaces: 09.07 ype E-.SE 6...XH ype W-.SE 6...XH Size 6 Component series 6X Maximum operating pressure 40 bar Maximum flow

More information

TESTO ITC KORINNA 28mm Allargato LOAD SENSING MONOBLOCK DIRECTIONAL CONTROL VALVE

TESTO ITC KORINNA 28mm Allargato LOAD SENSING MONOBLOCK DIRECTIONAL CONTROL VALVE ESO IC KORINN 28mm llargato LOD SENSING MONOLOCK DIRECIONL CONROL VLVE Features Simple, compact and heavy duty designed 2 sections monoblock valve, for hydraulic systems with load sensing variable displacement

More information

VQ1000. How to Order Manifold. Kit type

VQ1000. How to Order Manifold. Kit type - - ase Mounted VQ000/000 Manifold type D-sub connector ort Solenoid Valve Flat ribbon cable Connector Serial Directional Control Valves VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold

More information

Pump Safety Block Model DBA... / DBAW, Series 1X

Pump Safety Block Model DBA... / DBAW, Series 1X ump Safety lock odel D... / DW, Series X Sizes to 6 SI ( bar) 7 G (65 L/min) R 5 88/.95 Replaces:.9 ermits low pressure start-up and by-pass of pump Direct mounting to SE pressure port of pump Light biasing

More information

MDT. Monoblock directional control valves MDT - Directional control valve

MDT. Monoblock directional control valves MDT - Directional control valve Monoblock directional control valves - Directional control valve efore use, carefully read the GENERL INSRUCIONS FOR USE OF DIRECIONL CONROL VLVES echnical data Nominal flow 35 l/min 9. US gpm Nominal

More information

NG6. Proportional adjustment. Manifold mounting acc. to ISO External drain. Main stage spool type valve. Pilot stage seated type valve.

NG6. Proportional adjustment. Manifold mounting acc. to ISO External drain. Main stage spool type valve. Pilot stage seated type valve. Catalog HY14-255/US Technical Information Series VY*K General Description Series VY*K pilot operated sequence valves feature proportional adjustment and an external drain. The external drain allows application

More information

Proportional Valves. Proportional Two-Stage Directional Valves

Proportional Valves. Proportional Two-Stage Directional Valves VICKERS roportional Valves roportional Two-Stage Directional Valves KHDG5V-5/7, 1 Series ressures to 3 bar ( psi) This product has been designed and tested to meet specific standards outlined in the European

More information

3/2 and 4/2 directional poppet valve with solenoid actuation

3/2 and 4/2 directional poppet valve with solenoid actuation Courtesy of CM/Flodyne/Hydradyne Motion Control Hydraulic neumatic Electrical Mechanical (800) 426-5480 www.cmafh.com 3/2 and 4/2 directional poppet valve with solenoid actuation ype M-.SED Size 10 Component

More information

Pilot Operated Directional Control Valves Series D1VP, D3DP, D4P, D9P, D11P

Pilot Operated Directional Control Valves Series D1VP, D3DP, D4P, D9P, D11P Characteristics Series D1VP, D3DP, D4P, D9P, D11P The D1VP is a hydraulically controlled 4/3 or 4/ way directional control valve. The valve can be operated either by the pilot ports X and Y via the subplate

More information

EManually Operated Directional Valves

EManually Operated Directional Valves DIRECIONL CONROLS hese valves may be used to manually shift the spool position and change the direction of oil flow. hreaded Connections Sub-late Mounting Specifications DM--C - DM--D - DM--D - DM--B -

More information

Proportional Directional Valve System

Proportional Directional Valve System roportional Directional Valve System in Sectional Design Reference: 31--9589-ENG-2 Issue: 8.215 1/2 Contents age 1 General... 3 1.1 Description... 3 1.2 pplication examples... 3 2 Technical data... 3 3

More information

4/3-4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections

4/3-4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections 4/3-4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections RE 18301-12/07.12 1/10 D8_5 (EDD-XZ) Size 8 Series 00 Maximum pressure (pump side) 310 [4500

More information

Pressure Control Valves. General Description. Specifications. Ordering Information

Pressure Control Valves. General Description. Specifications. Ordering Information Catalog HY14-3000/US Technical Information Control Valves Series RCP General escription Series RCP in-line pressure control valves are chiefly used as remote control valves. They limit system pressure

More information

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX: SPECIFICAIONS D05 Pattern Directional Control Valves Also refer to "Directional Valve Features, Selection and Operating Recommendations" (dynexdcvoperating.pdf) CONAC INFORMAION USA Headquarters Dynex/Rivett

More information

Directional Controls

Directional Controls Vickers Directional Controls Wet Armature Solenoid Operated Directional Control Valves Model DGV-, Series Typical Construction of a Spring-Centered DC Valve with Variable Speed Pilot Control passage Speed

More information

Proportional Directional Control Valves Series D*1FE. General Description. Features. D41FE Standard

Proportional Directional Control Valves Series D*1FE. General Description. Features. D41FE Standard Technical Information General Description pilot operated proportional valves are designed for high precision applications that require a safe middle position of the main spool at power down. The pilot

More information

Chapter 6: Check Valves

Chapter 6: Check Valves Contents Chapter : Check Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 0 10 1 25 32 Subplate Screw-in Slip-in Shuttle valves SSR -2 Check valves, direct operated

More information

EMechanically Operated Directional Valves

EMechanically Operated Directional Valves E DIRECIONL CONROLS Cam Operated Directional Valves hese valves may be used to shift the direction of oil flow by depressing the spool by way of a cam. Specifications Max. Operating Max. -Line Max. Flow

More information

3/2 and 4/2 directional seat valves with solenoid actuation

3/2 and 4/2 directional seat valves with solenoid actuation 1/16 /2 and 4/2 directional seat valves with solenoid actuation RE 22047-XH-B2/09.12 Replaces: 05.12 ype E-.SE 6...X... ype W-.SE 6...X... Size 6 Component series 6X Maximum operating pressure 420 bar

More information

4/3-way high response directional control valve pilot operated with electrical feedback and integrated electronics (OBE)

4/3-way high response directional control valve pilot operated with electrical feedback and integrated electronics (OBE) 4/3-way high response directional control valve pilot operated with electrical feedback and integrated electronics (OE) ype 4WRDE Nominal size to 35 Component series 5X Maximum operating pressure 3 bar

More information

D03 FluiDyne Valves. ENGINEERING DATA

D03 FluiDyne Valves.   ENGINEERING DATA ENGINEERING D D3 FluiDyne Valves 4 Way, and 3 Postion Solenoid Operated Variety of Voltage and Spool Configurations Same Day Shipments 1 Month Warranty www.fluidynefp.com D3 FluiDyne Valves: 4 Way, and

More information

Monobloc and Sectional Directional Control Valves

Monobloc and Sectional Directional Control Valves Monobloc and Sectional Directional Control Valves motion and progress 1/220 10 Sectional directional control valves HDS20 Contents 10.1 General specifications 177 10.2 Dimensional data 178 10.3 erformances

More information

Series Shockless Type Solenoid Controlled Pilot Operated Directional Valves

Series Shockless Type Solenoid Controlled Pilot Operated Directional Valves Solenoid Controlled ilot Operated Directional Valves Electronic Circuit X Specifications Descriptions G-DSHG-4-3C - - - -/9 G-DSHG-6-3C - - - -/9 Max. Flow /min (U.S.GM) 16 (4.3) (66.1) 1 1 Max. Operating

More information

Directional Control Valves

Directional Control Valves Frequently sked Questions Frequently sked Questions What is the function of a directional control valve? directional control valve is the extend and retract control for your hydraulic cylinders. It provides

More information

Pilot Operated Directional Valves

Pilot Operated Directional Valves ilot Operated Directional Valves Catalog DG3V-8; 7 l/min (185 USgpm) 35 bar (5 psi) DG5V-8; 7 l/min (185 USgpm) 35 bar (5 psi) NF D8, ISO-441-8, CEO 8 Introduction General Description he Size 8 Directiona

More information

Auxiliary valves PLC series Direct-acting pressure relief valves

Auxiliary valves PLC series Direct-acting pressure relief valves uxiliary valves LC series Direct-acting pressure relief valves Catalogue HY17-872/UK ugust 25 Catalogue HY17-872/UK Contents LC series List of contents age General Information... 3 LC53... Single housing

More information

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308

Cable Appendix. Valves. Cable Appendix. Page 16. Multi-way cables. D-sub Connector Cables. AXT100-DS Conforming to MIL-C-24308 Cable ppendix Cable ppendix Multi-way cables The multi-pole connector cables used on SMC valves are common across several ranges. Cables are available in accordance with the MIL standard C-08 and also

More information

Accessories Series PSB. Specifications

Accessories Series PSB. Specifications Catalog HY14-252/US Technical Information General Description electrohydraulic pressure switches are high performance devices that provide an electrical signal when sensed pressure rises above or falls

More information

Pressure Control Valves Series R. General Description. Specifications. Flow Data

Pressure Control Valves Series R. General Description. Specifications. Flow Data Catalog Y14-2502/US Technical Information Series R General Description Series R direct relief valves limit system pressure by opening to tank when system pressure reaches the valve setting. Specifications

More information

RA / /3, 4/2 and 3/2-Way Directional Valves Model.WE 10.../.D, Series 3X with Wet Pin DC Solenoids. Functional description, section

RA / /3, 4/2 and 3/2-Way Directional Valves Model.WE 10.../.D, Series 3X with Wet Pin DC Solenoids. Functional description, section 4/3, 4/2 and 3/2-Way Directional Valves Model.WE.../.D, Series 3X with Wet in DC Solenoids Size (D )... 3 SI... 2 GM (2 ar) (8 L/min) RA 23 37/6.98 Replaces: 2.96 Features: Direct solenoid operated directional

More information