1 Explosion-Proof Valves ccording to Directive 94/9/EC (EX) and IECEx Requirements

2 WRNING USER RESPONSIILIY FILURE OR IMPROPER SELECION OR IMPROPER USE OF HE PRODUCS DESCRIED HEREIN OR RELED IEMS CN CUSE DEH, PERSONL INJURY ND PROPERY DMGE. his document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise. he user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. he user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors. o the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems. Offer of Sale Please contact your Parker representation for a detailed Offer of Sale.

3 Contents Explosion-Proof Valves Description Page Introduction 4 D1VW Explosion Proof Characteristics, echnical Data 6 Ordering 7 Flow Curves 8 Shift Limits 9 Dimensions 10 D*W*EE Explosion Proof Characteristics 11 Ordering 12 echnical Data 14 Flow Curves 15 Pilot Oil Options 17 Dimensions 18 D1F*EE Explosion Proof Characteristics 21 Ordering 22 echnical Data 23 Characteristic Curves 24 Dimensions 26 D1FV*EE Explosion Proof Characteristics 27 Ordering, Characteristics Curves 28 echnical Data 29 Dimensions 30 D*1F*EE Explosion Proof Characteristics 31 Ordering 32 echnical Data, Characteristics Curves 33 Pilot Oil Options 34 Dimensions 35 RE06M*W*EE Explosion Proof Characteristics 37 Ordering, echnical Data 38 Characteristics Curves 39 Dimensions 41 3

4 Introduction Explosion-Proof Valves Explosion-proof valves: now also available with IECEx-certified solenoids Parker has expanded the range of application for its explosion-proof industry hydraulic valves. ll series (exception: RE06M*W*EE) are not only EX certified but also equipped with IECEx compliant solenoids. Parker has certified the solenoids of these explosionproof directional control valves in accordance with IECEx standard for equipment class 2 G, as well ensuring EX compliance. echnically-speaking the new valves are practically unchanged. oth the performance characteristics and the dimensions are identical to the values of the previous versions, so that the valves can also easily be used as a replacement in existing systems. mong other things, the provided operating instructions contain: EC declaration of conformity for the valve Safety instructions Operating instructions, CE type examination certificate and declaration of conformity for the solenoids ll valves offered in this catalogue are EX certified for usage in zone 1 and 2, series RE06M*W*EE additionally for zones 21 and 22. Group I Mining-equipment Group II Non-mining equipment Category M Category 1 Category 2 Category G D G D G D Gas: Zone 0 Dust: Zone 20 Gas: Zone 1 Dust: Zone 21 Gas: Zone 2 Dust: Zone 22 Very high level of protection. Equipment can be operated in presence of explosive atmospheres. Covered by means of two protective safety measures. High level of protection. Equipment to be de-energised in presence of explosive atmospheres. Very high level of protection. Used where explosive atmospheres are present continuously or for long periods of time. Covered by means of two protective safety measures. High level of protection. Used where explosive atmospheres are likely to occur in normal service. Normal level of protection. Used where explosive atmospheres are unlikely to occur and would be infrequent and for short time only. 4

5 Notes 5

6 Characteristics / echnical Data Directional Control Valve Series D1VW Explosion Proof he D1VW with explosion proof solenoids is based on the standard D1VW series. he specific solenoid design allows the usage in hazardous environments. he explosion proof class is Ex e mb II 4 Gb for use in zone 1 and 2 (conform to EX). dditionally the solenoids have IECEx conformity. ll explosion proof solenoids are DC design. he valves for C operate with integrated rectifier. echnical data General Design ctuation Size Mounting interface Mounting position Directional spool valve Solenoid mbient temperature [ C] MF D [years] 150 Weight Hydraulic Max. operating pressure [bar] P, : 350 : 140 DIN NG06 / CEOP 03 / NFP D03 DIN / ISO 4401 / CEOP RP 121-H / NFP D03 unrestricted, preferably horizontal [kg] 1.8 (1 solenoid), 2.7 (2 solenoids) Fluid Hydraulic oil in accordance with DIN Fluid temperature [ C] Viscosity permitted [cst] / [mm²/s] Viscosity recommended [cst] / [mm²/s] Filtration ISO 4406 (1999); 18/16/13 Flow max. [l/min] 60 Leakage at 50 bar Static / Dynamic Step response at 95 % Electrical characteristics Duty ratio Max. switching frequency [ml/min] Up to 10 per flow path, depending on spool [ms] Energized: 32 (DC), 40 (C) / De-energized: 40 (DC), 75 (C) 100 % ED; CUION: coil temperature up to 135 C possible [1/h] (DC), 7200 (C) Protection class, Ex e mb II 4 Gb, IP66 (plugged and mounted correctly) J N P Supply voltage / ripple [V] 24 V = 230 V / 50 Hz 110 V / 50 Hz olerance supply voltage [%] ±10 ±10 ±10 Current consumption [] Power consumption [W] Solenoid connection ox with M20x1.5 entry for cable glands. Solenoid identification as per ISO Wiring min. Wiring length max. [mm²] 3 x 1.5 recommended [m] 50 recommended With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations. 6

7 Ordering Directional Control Valve Series D1VW Explosion Proof D 1 V W E E Directional control valve Size DIN NG06 CEOP 03 NFP D03 3-chamber valve Wet pin solenoid Spool type Spool position Seal Solenoid voltage Connection: Explosion proof with cable glands Design series (not required for ordering) Solenoid options: Explosionproof Ex e mb II 4 Gb + IECEx conformity 3 position spools Spool type a 0 b 001 Voltage J 24 V= P 110 V / 50 Hz N 230 V / 50 Hz N V Seal NR FPM ) 009 1) 010 C 3 position spools all 3 position spools Standard Spool type 008, positions. Spring offset in position 0. Operated in position a or b E Operated in position a. Operated in position b. 2 positions. Spring offset in position K Operated in position b. Operated in position a. 2 positions. Spring offset in position position spools Spool type a b a b P D H 2 position spools Spool position 2 positions. Spring offset in position b. Operated in position a. 2 positions. Operated in position a or b. No center or offset position. 2 positions. Spring offset in position a. Operated in position b. Further spool types, styles and combinations on request ) Consider specific spool position. 7

8 Flow Curves Directional Control Valve Series D1VW Explosion Proof he flow curve diagram shows the flow versus pressure drop curves for all spool types. he relevant curve number for each spool type, operating position and flow direction is given in the table below. Spool Position b Position a Position 0 P- - P- P- - P- P- P- - - P ) 1) P- - P- - P- P- - - P Position b Position a Spool P- P- - P P- - P- P ) Only for pressure compensation, no high flow possible. Flow curve Pressure drop [bar] ll characteristic curves measured with HLP46 at 50 C Flow [l/min] 8

9 Shift Limits Directional Control Valve Series D1VW Explosion Proof he diagram below specifies the shift limits for valves with C and DC solenoids. he specifications apply to balanced flow conditions. he shift limits can be considerably lower at unbalanced flow conditions. o avoid flow rates beyond the shift limits, a plug-in orifice can be inserted in the P port. Shift limit diagram with DC solenoid Supply pressure [bar] , 011, 014, 082, , , 020, , Supply pressure [bar] , , 005, 010, 016, 021, Flow [l/min] Flow [l/min] Measured with HLP46 at 50 C, 90 % U nom and warm solenoids Shift limit diagram with C solenoid Supply pressure [bar] , , Supply pressure [bar] , 014, Flow [l/min] Flow [l/min] Measured with HLP46 at 50 C, 95 % U nom and warm solenoids 9

10 Dimensions Directional Control Valve Series D1VW Explosion Proof, E -style H, K -style C, D -style Surface finish K375 4x M5x30 ISO Nm ±15 % NR: SK-D1VW-N-91 FPM: SK-D1VW-V-91 10

11 Characteristics Pilot Operated Directional Control Valve Series D*W*EE Explosion Proof he D*1*W*EE with explosion proof solenoids is based on the standard D*1*W series. he specific solenoid design allows the usage in hazardous environments. he explosion proof class is Ex e mb II 4 Gb for use in zone 1 and 2 (conform to EX). dditionally the solenoids have IECEx conformity. ll explosion proof solenoids are DC design. he valves for C operate with integrated rectifier. he pilot operated valves are available in 4 sizes: D31DW NG10 (standard) D31NW NG10 (high flow) D41VW NG16 D91VW NG25 (for port diameter up to 32 mm) D111VW NG32 ll valves are piloted by a D1VW valve. he minimum pilot pressure must be ensured for all operating conditions of the directional valve. dditionally spools with a P to connection in the deenergized position need an external pressure supply (external inlet) or an integral check valve. D31DW D31NW D41VW D91VW D111VW D91VW P X/Y 11

12 Ordering Pilot Operated Directional Control Valve Series D*W*EE Explosion Proof Series Spool type Spool position ore Size Feature D31DW Ø11 mm NG10 D31NW Ø11 mm NG10 High flow D41VW Ø20 mm NG16 D91VW Ø32 mm NG25 D111VW Ø50 mm NG32 3 position spool Spool type a 0 b 001 2) 002 2) 003 3) C 2) 3 position spool Spool position 3 positions. Spring offset in position 0. Operated in position a or b. Standard Spool type ) 005 3) 006 3) E 2) Operated in position a. Operated in position b. 2 positions. Spring offset in position ) 2) 011 3) 015 3) F 2) Spring offset in position b. Spring offset in position a. 2 positions. Operated in position ) 021 3) K 2) Operated in position b. Operated in position a. 2 positions. Spring offset in position ) 2 position spool Spool type a b 020 2) 030 2) M 2) R 3) S 3) Spring offset in position a. No centre in offset position. No centre in offset position. Spring offset in position b. No centre in offset position. No centre in offset position. 2 positions. Operated in position 0. 2 positions, detent. Operated in position 0 or b. 2 positions, detent. Operated in position 0 or a. No center in offset position. 1) Consider specific spool position. 2) ll sizes (D31, D41, D 91, D111) available 3) Only D31, D41, D91 available 4) Not for D31DW and D111VW available. 5) Not for spools 002, 009 available. 6) Only D31, D41, D91 available. 2) D 3) H 2) 2 position spools Spool position Spring offset in position b. Operated in position a. Detent, operated in position a or b. No center or offset position. Spring offset in position a. Operated in position b. 12

13 Ordering Pilot Operated Directional Control Valve Series D*W*EE Explosion Proof E E Pilot oil supply and drain options Seals Solenoid voltage Connection: Explosion proof with cable glands Solenoid options: Explosion proof Ex e mb II 4 Gb + IECEx conformity ccessories Design series (not required for ordering) ohne 3 3 3C 3D 6) 3E 6) 3F 3R 1 ccessories Standard valve w/o accessories Pilot choke, meter-out Pilot choke, meter-in Pilot with pressure reducing valve Stroke adjustment side Stroke adjustment side Stroke adjustment side and meter-out / pressure reducing valve meter-in / pressure reducing valve Solenoid voltage J 24 V = N 230 V / 50 Hz P 110 V / 50 Hz N V Seals NR FPM Further spool types on request. Inlet Outlet 1 Internal External 2 External External 3 4) Integral External check valve 4 5) Internal Internal 5 External Internal 6 4) Integral check valve Internal 13

14 echnical Data Pilot Operated Directional Control Valve Series D*W*EE Explosion Proof General Design Directional spool valve ctuation Solenoid Series D31DW D31NW D41VW D91VW D111VW Size NG10 NG10 NG16 NG25 NG32 Weight (1/ 2 solenoids) [kg] 6.0 / / / / / 68.0 Mounting interface DIN DIN DIN DIN DIN ISO 4401 ISO 4401 ISO 4401 ISO 4401 ISO 4401 NFP D05 NFP D05 NFP D07 NFP D08 NFP D10 CEOP RP 121-H Mounting position unrestricted, preferably horizontal mbient temperature [ C] MF D value [years] 75 Hydraulic Max. operating pressure [bar] P,, : 350; : 140 Fluid Hydraulic oil in accordance with DIN Fluid temperature [ C] Viscosity permitted [cst] / [mm²/s] Viscosity recommended [cst] / [mm²/s] Filtration ISO 4406 (1999); 18/16/13 Flow max. [l/min] Leakage at 350 bar (per flow path) [ml/min] up to 100* up to 150* up to 200* up to 800* up to 5000* *depending on spool Opening pressure integral check valve [bar] n.a. n.a. see p/q diagram see p/q diagram n.a. Minimum pilot supply pressure [bar] Static / Dynamic Step response at 95 % [ms] Energized / De-energized DC solenoids Pilot pressure 50 bar 100 bar 250 bar 350 bar C solenoids Pilot pressure Electrical characteristics Duty ratio 50 bar 100 bar 250 bar 350 bar 60 / 40 (50/60) 95 / / / / 40 (50/60) 75 / / / / 40 (50/50) 60 / / / / 40 (50/50) 60 / / / / 30 (30/50) 75 / / / / 30 (30/50) 65 / / / / 30 (30/50) 40 / / / / 30 (30/50) 40 / / / % ED; CUION: coil temperature up to 135 C possible Protection class, Ex e mb II 4 Gb, IP66 (plugged and mounted correctly) J N P Supply voltage / ripple [V] 24 V = 230V / 50 Hz 110V / 50 Hz olerance supply voltage [%] ±10 ±10 ±10 Current consumption [] Power consumption [W] Solenoid connection ox with M20x1.5 entry for cable glands. Solenoid identification as per ISO Wiring min. [mm²] 3 x 1.5 recommended Wiring length max. [m] 50 recommended With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations. 14

15 Flow Curves Pilot Operated Directional Control Valve Series D*W*EE Explosion Proof he flow curve diagram shows the flow versus pressure drop curves for all spool types. he relevant curve number for each spool type, operating position and flow direction is given in the table below. D31DW and D41VW Spool Curve number P- P- P- - - D3 D4 D3 D4 D3 D4 D3 D4 D3 D D31NW Spool Curve number P- P- P ll characteristic curves measured with HLP46 at 50 C. 15

16 Flow Curves Pilot Operated Directional Control Valve Series D*W*EE Explosion Proof D91VW and D111VW Spool Curve number P- P- P- - - D9 D11 D9 D11 D9 D11 D9 D11 D9 D Pressure drop p [bar] D91VW Flow Q [l/min] Integral check valve in the P port Mounting an integral check valve in the P port is necessary to build up pilot pressure for valves with P to connection and internal pilot oil supply. he pressure difference at the integral check valve (see performance curves) is to be added to all flow curves of the P port of the main valve. Directional valves with an integral check valve are available for the series D31NW and D41VW. Flow curve D31NW Flow curve D91VW Flow curve D41VW 16

17 Pilot Oil Options Pilot Operated Directional Control Valve Series D*W*EE Explosion Proof D31DW D31NW D41VW D91VW D111VW ll orifice sizes for standard valves 17

18 Dimensions Pilot Operated Directional Control Valve Series D*W*EE Explosion Proof D31DW Surface finish K385 4x M6x40 ISO Nm ±15 % NR: SK-D31DW-N-91 FPM: SK-D31DW-V-91 D31NW Surface finish K385 4x M6x40 ISO Nm ±15 % NR: SK-4D02V-1 FPM: SK-4D02V-5 18

19 Dimensions Pilot Operated Directional Control Valve Series D*W*EE Explosion Proof D41VW Surface finish K320 4x M10x60 2xM6x55 ISO Nm ±15 % 13.2 Nm ±15 % NR: SK-D41VW-N-91 FPM: SK-D41VW-V-91 D91VW Ø Surface finish K385 4x M6x40 ISO Nm ±15 % NR: SK-D81VW-N-91 / SK-D91VW-N-91 FPM: SK-D81VW-V-91 / SK-D91VW-V-91 19

20 Dimensions Pilot Operated Directional Control Valve Series D*W*EE Explosion Proof D111VW Ø Surface finish K386 6x M20x90 ISO Nm ±15 % NR: SK-D111VW-N-91 FPM: SK-D111VW-V-91 20

21 Characteristics Direct Operated Proportional DC Valve Series D1F*EE Explosion Proof he D1F*EE series with explosion proof solenoids is based on the standard D1F series. he specific solenoid design allows the usage in hazardous environments. he explosion proof class is a 0 b Ex e mb II 4 Gb for use in zone 1 and 2 (conform to EX). dditionally the solenoids have IECEx conformity. he parameters can be saved, changed and duplicated in combination with the digital power amplifier PWD (to be used in an explosion proof cabinet or outside of the hazardous area). he valve parameters can be edited with the common ProPxD software. he D1F valves can be ordered with spool/sleeve design (D1F*0) for maximum precision as well as spool/ body design (D1F*3) for high nominal flow - see functional limit curves for maximum flow capability. P echnical features Spool/sleeve and spool/body High repeatability from valve to valve Low hysteresis Manual override D1F*0*EE Spool/sleeve design D1F*3*EE Spool/body design 21

22 Ordering Direct Operated Proportional DC Valve Series D1F*EE Explosion Proof D 1 F 0 N E EE Directional control valve Proportional control Spool Seals NR (other seal compounds on request) Explosion proof Design series (not required for ordering) Size DIN NG06 CEOP 03 NFP D03 Standard dynamics standard repeatability Spool position Solenoid Design Connection Explosion proof with cable glands Ex e mb II 4 Gb + IECEx conformity E01H E01F E01C E02H E02F E02C E03H E03F E03C 31H 31F 32H 32F D1F*0*EE: Spool/sleeve design Spool type Q = Q /2 Q = Q /2 Flow [l/min] at Dp 5 bar per metering edge / / 6 20 / / 6 C E 0 3 K J Design Spool/sleeve design Spool/body design Solenoid 12 V / V / 1.15 Spool position E01K E01H E01F E02K E02H E02F D1F*3*EE: Spool/body design Spool type Flow [l/min] at Dp 5 bar per metering edge K 22

23 echnical Data Direct Operated Proportional DC Valve Series D1F*EE Explosion Proof General Design ctuation Size Mounting interface Mounting position Direct operated proportional DC valve Proportional solenoid NG06/CEOP 03/NFP D03 DIN / ISO 4401 / CEOP RP121 / NFP unrestricted mbient temperature [ C] MF D value [years] 150 Weight [kg] 3.5 (2 solenoids), 2.5 (1 solenoid) Vibration resistance [g] 10 Sinus Hz acc. IEC Random noise Hz acc. IEC Shock acc. IEC Hydraulic Max. operating pressure [bar] Ports P,, 350; Port 210 Max. pressure drop P / P [bar] 350 Fluid Fluid temperature [ C] Viscosity permitted [cst] / [mm 2 /s] recommended [cst] / [mm 2 /s] Hydraulic oil as per DIN , other on request Filtration ISO 4406 (1999); 18/16/13 Nominal flow at p = 5 bar per control edge * D1F*0*EE (Spool/sleeve) With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations. D1F*3*EE (Spool/body) [l/min] 6 / 12 / / 20 / 30 Leakage at 100 bar [ml/min] <50 <60 Overlap Static / Dynamic [%] 25, electrically normalized at 10 (see flow characteristics) Step response at 100 % step [ms] Hysteresis [%] <4 <6 emperature drift solenoid current [%/K] <0.02 Electrical characteristics Duty ratio [%] 100 Protection class, Ex e mb II 4 Gb, IP66 (plugged and mounted correctly) Solenoid J K Supply voltage [V] Current consumption [] Resistance [Ohm] Solenoid connection ox with M20x1.5 entry for cableglands. Solenoid identifications per ISO Wiring min. Wiring length max. [mm²] 3 x 1.5 recommended [m] 50 recommended * Flow rate for different p per control edge: Q x = Q Nom. p x p Nom. 23

24 Characteristic Curves Direct Operated Proportional DC Valve Series D1F*EE Explosion Proof Flow characteristics D1F*0*EE at p = 5 bar per metering edge 100 Spool type E* 75 Flow Q [% of nominal flow] P- - P Command signal [%] 100 Spool type * Flow Q [% of nominal flow] P- P Command signal [%] Functional limits at 25 %, 50 %, 75 % and 100 % command signal (symmetric flow) t asymmetric flow a reduced flow limit has to be considered typically approx. 10 % lower. Spool type E01H ll characteristic curves measured with HLP46 at 50 C. 24

25 Characteristic Curves Direct Operated Proportional DC Valve Series D1F*EE Explosion Proof Flow characteristics D1F*3*EE at p = 5 bar per metering edge Flow Q [% of nominal flow] P- - Spool type E* P Command signal [%] Functional limits at 25 %, 50 %, 75 % and 100 % command signal (symmetric flow) t asymmetric flow a reduced flow limit has to be considered typically approx. 10 % lower. Spool type E01K ll characteristic curves measured with HLP46 at 50 C. 25

26 Dimensions Direct Operated Proportional DC Valve Series D1F*EE Explosion Proof D1F*C*EE D1F*K*EE D1F*E*EE Surface finish NR K375 4x M5x30 ISO Nm ±15 % SK-D1F-N 26

27 Characteristics Proportional Pressure Reducing Valve Series D1FV*EE Explosion Proof he D1FV*EE series with explosion proof solenoids is based on the standard D1FV series. he specific solenoid design allows the usage in hazardous environments. he explosion proof class is P P Ex e mb II 4 Gb a P b for use in zone 1 and 2 (conform to EX). dditionally the solenoids have IECEx conformity. he parameters can be saved, changed and duplicated in combination with the digital power amplifier PWD (to be used in an explosion proof cabinet or outside of the hazardous area). he valve parameters can be edited with the common ProPxD software. he D1FV valves control the pressure in the or ports using the barometric feedback principle. Schematics Control function C a P P Example function C b P echnical features arometric feedback High repeatability from valve to valve Low hysteresis Manual override Control function E a P P P Control function K P P b P 27

28 Ordering / Curves Proportional Pressure Reducing Valve Series D1FV*EE Explosion Proof Ordering code D 1 F V E02 C 0 V E 3 EE Proportional pressure reducing valve Proportional control Spool Control function Seals FPM Explosion proof Design series (not required for ordering) Size DIN NG06 CEOP 03 NFP D03 Pressure range 25 bar Solenoid Spool/body design Connection Explosion proof with cable glands Ex e mb II 4 Gb + IECEx conformity C Spool position K J Solenoid 12 V / V / 1.15 E K Characteristic curves reduced pressure p [%] P- P- Pressure drop p [bar] P- / P Command signal [%] - / Flow [l/min] ll characteristic curves measured with HLP46 at 50 C. 28

29 echnical Data Proportional Pressure Reducing Valve Series D1FV*EE Explosion Proof General Design ctuation Size Mounting interface Mounting position Direct operated proportional pressure reducing valve Proportional solenoid NG06 / CEOP 03 / NFP D03 DIN / ISO 4401 / CEOP RP121 / NFP unrestricted mbient temperature [ C] MF D value [years] 150 Weight [kg] 3.5 (2 solenoids), 2.5 (1 solenoid) Vibration resistance [g] 10 Sinus Hz acc. IEC Random noise Hz acc. IEC Shock acc. IEC Hydraulic Max. operating pressure [bar] Ports P,, 350; Port 185 Max. pressure drop P / P [bar] 350 Fluid Fluid temperature [ C] Viscosity permitted [cst] / recommended [cst] / [mm 2 /s] [mm 2 /s] Hydraulic oil as per DIN , other on request Filtration ISO 4406 (1999); 18/16/13 Max. flow [l/min] 10 Min. primary pressure [bar] 30 Static / Dynamic Hysteresis [%] <4 emperature drift solenoid current [%/K] <0.02 Electrical characteristics Duty ratio [%] 100 Protection class, Ex e mb II 4 Gb, IP66 (plugged and mounted correctly) Solenoid J K Supply voltage [V] Current consumption [] Resistance [Ohm] Solenoid connection ox with M20x1.5 entry for cableglands. Solenoid identifications per ISO Wiring min. Wiring length max. [mm²] 3 x 1.5 recommended [m] 50 recommended With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations. 29

30 Dimensions Proportional Pressure Reducing Valve Series D1FV*EE Explosion Proof D1FV*C*EE D1FV*K*EE D1FV*E*EE Surface finish NR K375 4x M5x30 ISO Nm ±15% SK-D1F-N 30

31 Characteristics Pilot Operated Proportional DC Valve Series D*1F*EE Explosion Proof he series of pilot operated proportional directional valves D*1F*EE is offered in 4 sizes: D31F*EE - NG10 (CEOP 05) D41F*EE - NG16 (CEOP 07) D91F*EE - NG25 (CEOP 08) D111F*EE - NG32 (CEOP 10) he D*1F*EE series with explosion proof solenoids is based on the standard D*1F series. he specific solenoid design allows the usage in hazardous environments. he explosion proof class is D31F D41F Ex e mb II 4 Gb for use in zone 1 and 2 (conform to EX). dditionally the solenoids have IECEx conformity. he parameters can be saved, changed and duplicated in combination with the digital power amplifier PWD (to be used in an explosion proof cabinet or outside of the hazardous area). he valve parameters can be edited with the common ProPxD software. D91F D111F echnical features Progressive flow characteristics for sensitive adjustment of flow rate High flow capacity a 0 b P D91F*EE 31

32 Ordering Pilot Operated Proportional DC Valve Series D*1F*EE Explosion Proof D*1F D 1 F E 0 EE Directional control valve Size NG06 pilot Proportional control Dynamics standard Spool type Flow Spool position Pilot connection Seals Solenoid description Explosion proof Valve accessories Design series Connection: Explosion proof with cable glands Ex e mb II 4 Gb + IECEx conformity Nominal size 3 NG10 / CEOP 05 4 NG16 / CEOP ) NG25 / CEOP NG32 / CEOP 10 J K Solenoid description 24 V / V / 2.3 E01 Spool type N V Seals NR FPM E Q = Q /2 Q = Q /2 Inlet Drain 1 Internal External 2 External External 4 Internal Internal 5 External Internal Spool position Flow [l/min] at Dp = 5 bar per metering edge D31 D41 D91 D ) - - C 75 2) 130 2) - - D E ) - F H L C E K 1) With enlarged connections Ø 32 mm 2) Not for spool type 31 and 32 32

33 echnical Data / Curves Pilot Operated Proportional DC Valve Series D*1F*EE Explosion Proof General Design Pilot operated DC valve ctuation Proportional solenoid Size NG10 (CEOP 05) NG16 (CEOP 07) NG25 (CEOP 08) NG32 (CEOP 10) Mounting interface DIN / ISO 4401 / CEOP RP121 / NFP Mounting position unrestriced mbient temperature [ C] MF D value [years] 75 Weight [kg] Vibration resistance [g] 10 Sinus Hz acc. IEC Random noise Hz acc. IEC Shock acc. IEC Hydraulic Max. operating pressure [bar] [bar] Pilot drain internal: P,,, X 350;, Y 185 (NG10:, Y 15) Pilot drain external: P,,,, X 350; Y 185 (NG10: Y 15) Fluid Hydraulic oil as per DIN , other on request Fluid temperature [ C] Viscosity permitted [cst] / [mm 2 /s] recommended [cst] / [mm 2 /s] Filtration ISO 4406 (1999); 18/16/13 Nominal flow at Dp = 5 bar per control edge * [l/min] 75/90/ / / Leakage at 100 bar [ml/min] Pilot supply pressure [bar] [bar] [bar] min. 30 (+ /Y pressure) max. 350 optimal dynamics at 50 Pilot flow at 100bar [l/min] <0.5 <1.2 <1.2 <1.2 Pilot flow, step response [l/min] Static / Dynamic Step response at 100 % step [ms] Hysteresis [%] <5 Electrical characteristics Duty ratio [%] 100 Protection class, Ex e mb II 4 Gb, IP66 (plugged and mounted correctly) Solenoid K J Supply voltage [V] Current consumption [] Resistance [Ohm] Solenoid connection ox with M20x1.5 entry for cableglands. Solenoid identificationas per ISO Wiring min. Wiring lenght max. [mm²] 3 x 1.5 recommended [m] 50 recommended With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations. * Flow rate for different p per control edge: Q x = Q Nom. p x p Nom. Flow characteristics D*1F at p = 5 bar per metering edge Spool code E* Spool code * ll characteristic curves measured with HLP46 at 50 C. 33

34 X Y Catalogue HY /UK Pilot Oil Options Pilot Operated Proportional DC Valve Series D*1F*EE Explosion Proof Pilot oil inlet (supply) and outlet (drain) D31F P M6 DIN906 open, closed Pilot oil Inlet Drain C a 0 b Y (drawn offset) C M6 DIN906 internal external internal external external external internal internal )( )( P x y C D41F open, closed P Pilot oil Inlet Drain C internal external a 0 b C M6 DIN906 1/16 NPF external internal external external internal internal )( )( P x y C D91F open, closed P C M6 DIN906 1/16 NPF Pilot oil Inlet Drain C internal external internal external external external internal internal a 0 b )( )( P x y C D111F P C 1/16 NPF 1/16 NPF open, internal external internal external closed Pilot oil Inlet Drain C external external internal internal a 0 b )( )( P x y C 34

35 Dimensions Pilot Operated Proportional DC Valve Series D*1F*EE Explosion Proof D31F Surface finish K385 4x M6x40 ISO Nm ±15 % NR: SK-D31F-N FPM: SK-D31F-V D41F Surface finish K320 2x M6x55 4x M10x60 ISO Nm ±15 % 63 Nm ±15 % NR: SK-D41F-N FPM: SK-D41F-V 35

36 Dimensions Pilot Operated Proportional DC Valve Series D*1F*EE Explosion Proof D91F Ø Surface finish K360 6x M12x75 ISO Nm ±15 % NR: SK-D91F-N FPM: SK-D91F-V D111F Ø Surface finish K386 6x M20x90 ISO Nm ±15 % NR: SK-D111F-N FPM: SK-D111F-V 36

37 Characteristics Direct Operated Prop. Pressure Valve Series RE06M*W*EE Explosion Proof Pressure relief valves of the series RE06M*W*EE are direct operated proportional valves typically used as remote control valves for flow rates below 3 l/min. Function When the pressure in port P or exeeds the pressure setting at the solenoid, the cone opens to port and limits the pressure in port P to the adjusted level. he optimum performance can be achieved in combination with the digital amplifier module PCD (not explosion proof). he explosion proof class is II 2 GD c 130 C (4) for use in zones 1, 2, 21, and 22 (conform to EX). Features Direct operated with proportional solenoid Very low pressure adjustment of p min 2 pressure ports, and P (1 pressure port for XG087) Subplate mounting according to ISO pressure stages RE06M*W EE Standard RE06M*W EE XG087 RE06M*W*EE Standard RE06M*W*EE XG087 37

38 Ordering / echnical Data Direct Operated Prop. Pressure Valve Series RE06M*W*EE Explosion Proof Ordering code RE 06 M W 2 1 K E EE Proportional pressure relief valve NG06 Pressure stage bar bar bar Interface ISO 6264 Pressure External stage electronics Seals Normaly open Solenoid voltage 12 V Explosion Design ypes of Modification proof series protection (not required for solenoid on ordering) II 2 G EEx emb II 4 II 2 D EEx td 21 IP C N V Seals NR FPM omit XG087 Modification Standard P- and -port only, solenoid mounted on opposite side (see dimensions) echnical data General Nominal size DIN NG06 / CEOP 03 / NFP D03 Interface Subplate mounting according to ISO 6264 Mounting position as desired, horizontale mounting prefered mbient temperature [ C] MF D value [years] 150 Weight [kg] 2.0 Hydraulic Max. operating pressure [bar] Ports P and up to 350; port 30 Pressure stages [bar] 105, 210, 350 Nominal flow [l/min] 3 Fluid Hydraulic oil as per DIN Viscosity, recommended [cst] / [mm²/s] permitted [cst] / [mm²/s] Fluid temperature [ C] Filtration ISO 4406 (1999), 18/16/13 Linearity [%] ±2.8 Repeatability [%] <±1 Hysteresis [%] ±1.5 of p max Electrical Duty ratio [%] 100 ED Protection class IP 65 in accordance with EN (with correctly mounted plug-in connector) Nominal voltage [V] 12 (1.73 max. current) Coil resistance [Ohm] 3.3 at 20 C Solenoid connection Connector as per EN Power amplifier, recommended PCD (not explosion proof) Explosion protection rea of use according to directive 94/9/EG II 2 G II 2 D ype of protection - valve c 4 (EN ) c 130 C (EN ) ype of protection - solenoid II 2 G EEx emb II 4 II 2 D EEx td 21 IP C ype-examination certificate - solenoid PS EX Max. surface temperature [ C] 130 (4) For additional data and installation instructions see the operating instructions of the solenoid manufacturer. 38

39 Characteristic Curves Direct Operated Prop. Pressure Valve Series RE06M*W*EE Explosion Proof p/q curves Pressure stage 105 bar Pressure stage 210 bar Pressure stage 350 bar Min. adjusted pressure Pressure stage 105 bar Pressure stage 210 bar Pressure stage 350 bar ll characteristic curves measured with HLP46 at 50 C. 39

40 Characteristic Curves Direct Operated Prop. Pressure Valve Series RE06M*W*EE Explosion Proof Pressure/signal curve Pressure stage 105 bar Pressure stage 210 bar Pressure stage 350 bar ll characteristic curves measured with HLP46 at 50 C. 40

41 Dimensions RE06M*W*EE Standard Direct Operated Prop. Pressure Valve Series RE06M*W*EE Explosion Proof RE06M*W*EE XG087 Surface finish K375 4x M5x30 ISO Nm ±15 % NR: SK-RE06MWN FPM: SK-RE06MWV Mounting pattern ISO *-97 RE06M*W*EE Standard Port : O-ring recess diameter on valve body. RE06M*W*EE XG087 Port and : O-ring recess diameter on valve body. 41

42 Notes 42

43 Notes 43

44 2014. ll rights reserved. Catalogue HY /UK, POD, 09/2014, ZZ EME Product Information Centre Free phone: (from, E, CH, CZ, DE, DK, EE, ES, FI, FR, IE, IL, IS, I, LU, M, NL, NO, PL, P, RU, SE, SK, UK, Z) US Product Information Centre oll-free number: Your local authorized Parker distributor

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW Characteristics The pilot operated valves are available in 4 sizes: D31DW NG10 (standard) D31NW NG10 (high flow) D41VW NG16 D81VW NG5 (for port diameter up to 6 mm) D91VW NG5 (for port diameter up to 3

More information

Directional Control Valve

Directional Control Valve Characteristics The NG6 directional control valve series D1VW provides high functional limits up to 8 l/min in combination with a very low, energy-saving pressure drop. wide variety of spool options allows

More information

Directional Control Valve Series D1VW

Directional Control Valve Series D1VW Characteristics The NG6 directional control valve series D1VW provides high functional limits up to 8 l/min in combination with a very low, energy-saving pressure drop. A wide variety of spool options

More information

Chapter 2: Directional Control Valves

Chapter 2: Directional Control Valves Contents Chapter : Directional Control Valves Series Description Direct operated Pilot operated Page DIN / ISO 06 10 16 5 3 10 16 5 3 Seat valves, electrically operated D1SE - Spool valves, electrically

More information

Pilot-Operated Directional Control Valves Series D3 - D11

Pilot-Operated Directional Control Valves Series D3 - D11 Catalogue HY11-500/UK Characteristics The D31, D41, D81, D91 and D111 are electrical controlled 4/3 or 4/ way directional control valves. The valves are pilot-operated by an NG6 valve. Pressure and flow

More information

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW Characteristics The D31, D41, D81, D91 and D111 are electrically controlled 4/3 or 4/ way directional control valves. The valves are pilot operated by an NG6 valve. Pressure and flow of the pilot oil have

More information

Directional Control Valve Series D3W (Parker), 4D02 (Denison)

Directional Control Valve Series D3W (Parker), 4D02 (Denison) Characteristics Series D3W (Parker), 4D0 (Denison) The direct operated directional control valve size NG10 is available with both Parker (series D3W) and Denison (series 4D0) model codes. Both series are

More information

Directional Control Valve Series D3W Soft Shift

Directional Control Valve Series D3W Soft Shift Characteristics The D3W is a 3-chamber, electrically controlled 4/3 or 4/ way directional control valve. It is activated directly by solenoids with screwed in wet pin armature. The soft shifting of this

More information

Proportional Pressure Reducing Valve Series D1FV

Proportional Pressure Reducing Valve Series D1FV Characteristics roportional ressure Reducing Valve Series D1FV he proportional pressure reducing valves series D1FV are available with and without onboard electronics (OE). D1FV OE he digital onboard electronics

More information

Directional Control Valve Series 4D01 (DENISON)

Directional Control Valve Series 4D01 (DENISON) Characteristics The Denison series 4D01 is a solenoid operated directional control valve size NG06 in -chamber design. It is direct operated by wet pin solenoids. The 4D01 is available with a Soft Shift

More information

Pilot Operated Directional Control Valves Series D1VP, D3DP, D4P, D9P, D11P

Pilot Operated Directional Control Valves Series D1VP, D3DP, D4P, D9P, D11P Characteristics Series D1VP, D3DP, D4P, D9P, D11P The D1VP is a hydraulically controlled 4/3 or 4/ way directional control valve. The valve can be operated either by the pilot ports X and Y via the subplate

More information

Direct Operated Proportional DC Valves

Direct Operated Proportional DC Valves echnical Information Direct Operated roportional DC Valves Series D1F and D3F General Series D1F and D3F directional control valves of nominal sizes NG6 (CEO 3) and NG10 (CEO 5) respectively, provide variable

More information

Proportional Directional Control Valves Series D*1FB. General Description. Features D91FB OBE

Proportional Directional Control Valves Series D*1FB. General Description. Features D91FB OBE Technical Information Series D*1FB General Description Series D*1FB pilot operated proportional directional valves come in 4 sizes: D31FB NG10 (CETOP 5) D41FB NG16 (CETOP 7) D91FB NG25 (CETOP 8) D111FB

More information

Chapter 3: Proportional DC Valves

Chapter 3: Proportional DC Valves Catalogue HY11-5/UK Contents Chapter : Proportional DC Valves Series Description Size Operation Electronics LVDT Spool Design Page DIN/ISO direct pilot external onboard Overlap Zero lap Spool/ Sleeve Introduction

More information

Chapter 3: Proportional DC Valves

Chapter 3: Proportional DC Valves Catalogue HY11-5/UK Contents Chapter : Proportional DC Valves Series Description Size DIN/ISO direct pilot Operation Electronics external onboard LVDT Spool Design Page Overlap Zero lap Spool/ Sleeve Introduction

More information

Proportional Directional Control Valves Series D*1FE. General Description. Features. D41FE Standard

Proportional Directional Control Valves Series D*1FE. General Description. Features. D41FE Standard Technical Information General Description pilot operated proportional valves are designed for high precision applications that require a safe middle position of the main spool at power down. The pilot

More information

NG6. Proportional adjustment. Manifold mounting acc. to ISO External drain. Main stage spool type valve. Pilot stage seated type valve.

NG6. Proportional adjustment. Manifold mounting acc. to ISO External drain. Main stage spool type valve. Pilot stage seated type valve. Catalog HY14-255/US Technical Information Series VY*K General Description Series VY*K pilot operated sequence valves feature proportional adjustment and an external drain. The external drain allows application

More information

Pilot-Operated Proportional DC Valve Series D*1FH

Pilot-Operated Proportional DC Valve Series D*1FH Characteristics The pilot-operated proportional DC valves series of the D*1FH series are high-performance valves with electronic spool position feedback. These valves are available in sizes NG10 to NG2

More information

Directional Control Valves Series D111VW. General Description. Features. Performance Curves

Directional Control Valves Series D111VW. General Description. Features. Performance Curves Technical Information General valves are piloted by a D1VW valve. The valves can be ordered with position control. The minimum pilot pressure must be ensured for all operating conditions of the directional

More information

NG06. General Size NG6 NG10 Design

NG06. General Size NG6 NG10 Design Catalog HY14-255/US Series VY*K General Series VY*K pilot operated sequence valves feature proportional adjustment and an external drain. The external drain allows application as both a sequence valve

More information

ZRV. Direct Operated Check Valve Series ZRV (Denison)

ZRV. Direct Operated Check Valve Series ZRV (Denison) Characteristics / Ordering Code Direct Operated Check Valve Series ZRV (Denison) Direct operated check valves series ZRV have a cartridge type insert to provide zero leakage and high life time. he check

More information

Proportional Pressure Relief Valve Series RE*T

Proportional Pressure Relief Valve Series RE*T Characteristics The pressure relief valve series RE*T have a proportional solenoid operated pilot stage with integrated electronics and a cartridge main stage. Features Pilot-operated pressure relief valve

More information

Proportional Pressure Relief Valves Series R4V and R6V (Onboard Electronics) General Description. Features.

Proportional Pressure Relief Valves Series R4V and R6V (Onboard Electronics) General Description. Features. Catalog HY14-2/US Technical Information General Description Series R4V and R6V proportional pressure relief valves feature onboard electronics based on the functionality of the digital amplifier PCD. The

More information

Pilot Operated Proportional DC Valve Series D*1FW / D*1FT

Pilot Operated Proportional DC Valve Series D*1FW / D*1FT Characteristics The D*1FW / D*1FT pilot-operated proportional DC valves are available in NG10 (CETOP5), NG16 (CETOP7) and NG25 (CETOP8). These valves (D*1FW) are controlled electrically with the external

More information

Chapter 5: Flow Valves

Chapter 5: Flow Valves Catalogue HY11-300/UK Contents Chapter : Flow Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/4 3/8 1/2 3/4 1 06 10 16 Throttle valves, manual adjustment MVI -2 NS -4 FS With free

More information

Hydraulics 1. Directional Control Valves Series D1M. Features. Application. Operation. D1MW Solenoid Operated Free Lead Wire

Hydraulics 1. Directional Control Valves Series D1M. Features. Application. Operation. D1MW Solenoid Operated Free Lead Wire ulletin 2544-1/US Introduction pplication arker D1M Series hydraulic directional control valves are high performance, direct operated 4-way valves. hey are available in 2 or 3 position styles. hey are

More information

Publ. 3-EN 2950-A. DENISON HYDRAULICS Pressure Relief Valve R6V

Publ. 3-EN 2950-A. DENISON HYDRAULICS Pressure Relief Valve R6V Publ. 3-EN 2950-A DENISON HYDRAULICS Pressure Relief Valve R6V FEATURES, SYMBOL FEATURES High Performance: R6V valves are designed for a maximum pressure of 350 bar and a flow capacity up to 650 l/min.

More information

Proportional Pressure Reducing Valves Series PE*W (Parker), R4R (Denison)

Proportional Pressure Reducing Valves Series PE*W (Parker), R4R (Denison) Characteristics / Technical Data Series PE*W (Parker), RR (Denison) Subplate mounted proportional pressure reducing valves are available with both Parker (series PE*W) and Denison (series RR) model codes.

More information

Chapter 8: Slip-In Cartridge Valves

Chapter 8: Slip-In Cartridge Valves Contents Chapter : Slip-In Cartridge Series Description Size Page DIN / ISO 16 25 32 40 50 63 0 100125 2 way slip-in cartridge valves Introduction, hydraulic symbols, installation dimensions -2 CE / CP

More information

Pilot Operated Pressure Relief Valve Series R5V (Denison)

Pilot Operated Pressure Relief Valve Series R5V (Denison) Characteristics Pilot operated pressure relief valves series R5V have a similar design to the subplate mounted R4V series. The SAE flanges allow to mount the valves directly on the outlet flanges of pumps

More information

Chapter 7: Sandwich Valves

Chapter 7: Sandwich Valves Contents Chapter : Sandwich Valves Series Description Size Page DIN / ISO 06 10 16 25 DC valve Z1DW Shut-off valve -2 Pressure relief valves, manual operation RDM RM ZDV PRDM PRM ZDR Direct operated Pilot

More information

p max (see table of performances) Q max (see table of performances) bar Maximum flow l/min see par

p max (see table of performances) Q max (see table of performances) bar Maximum flow l/min see par 41 510/112 ED EXPLOSION-PROOF VERSION SOLENOID OPERATED DIRECTIONAL CONTROL VALVES in compliance with ATEX 94/9/EC MD1K ISO 4401-03 (CETOP 03) E4P4K CETOP P05 E07P4K ISO 4401-07 (CETOP 07) E5P4K ISO 4401-08

More information

3/2 and 4/2 directional seat valves with solenoid actuation

3/2 and 4/2 directional seat valves with solenoid actuation 1/16 /2 and 4/2 directional seat valves with solenoid actuation RE 22047-XH-B2/09.12 Replaces: 05.12 ype E-.SE 6...X... ype W-.SE 6...X... Size 6 Component series 6X Maximum operating pressure 420 bar

More information

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06 www.atos.com Table TF040-2/E Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06 A B DHRZO-A-012/25 A B DHRZA-A-010/25 DHRZ* are

More information

Directional Control Valves. General Description. Operation. Features

Directional Control Valves. General Description. Operation. Features echnical Information General Description W directional control valves are 5-chamber, pilot operated, solenoid controlled valves, hey are available in 2 or 3-position styles. hese valves are manifold or

More information

Intrinsically safe solenoid valves on/off controls - ATEX or IECEX certification

Intrinsically safe solenoid valves on/off controls - ATEX or IECEX certification Table E3-/E Intrinsically safe solenoid valves on/off controls - ATEX or IECEX certification valve body valve spool intrinsically safe solenoid electrical connector manual override DHW-6/WP/6 On/off valves

More information

DHAXW4-07*/M DHOXW-06* Input Power. 32 W (only for 12 and 24 DC) 40 W (only for 110 and 220 DC) 8 W 25 W T6 T4 8 W 25 W T4 T3 T6 T4 T4 T3 25 W 8 W

DHAXW4-07*/M DHOXW-06* Input Power. 32 W (only for 12 and 24 DC) 40 W (only for 110 and 220 DC) 8 W 25 W T6 T4 8 W 25 W T4 T3 T6 T4 T4 T3 25 W 8 W www.atos.com Table TE137obs/E Stainless steel valves for water base fluids standard or ex-proof solenoid valves with Multicertification TEX, IECEx, EC or CULUS certification UL certified valves are obsolete

More information

Chapter 6: Check Valves

Chapter 6: Check Valves Contents Chapter : Check Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 0 10 1 25 32 Subplate Screw-in Slip-in Shuttle valves SSR -2 Check valves, direct operated

More information

Directional control valves, pilot-operated, with electrical position feedback and integrated electronics (OBE) Type 4WRDE. Contents.

Directional control valves, pilot-operated, with electrical position feedback and integrated electronics (OBE) Type 4WRDE. Contents. Directional control valves, pilot-operated, with electrical position feedback and integrated electronics (OE) ype 4WRDE RE 997 Edition: 6-5 Replaces: 99 (NG and NG6) Sizes and 6 Component series 6X Maximum

More information

Proportional directional valves, pilot operated, with electrical position feedback and integrated electronics (OBE)

Proportional directional valves, pilot operated, with electrical position feedback and integrated electronics (OBE) Proportional directional valves, pilot operated, with electrical position feedback and integrated electronics (OE) RE 29075/08.13 Replaces: 08.04 1/22 Type 4WRKE Size 10 to 35 Component series 3X Maximum

More information

Directional Control Valves Series D81V. General Description. Operation. Features. Specifications

Directional Control Valves Series D81V. General Description. Operation. Features. Specifications echnical Information General Description W directional control valves are 5-chamber, pilot operated, solenoid controlled valves. hey are available in 2 or 3-position styles. hese valves are manifold or

More information

Proportional pressure relief valve Types DBE(M) and DBE(M)E

Proportional pressure relief valve Types DBE(M) and DBE(M)E RE 29 142/11.02 Replaces: 02.99 Proportional pressure relief valve Types DE(M) and DE(M)E Nominal size 32 1) Series 3X Maximum operating pressure 3 bar Maximum flow 600 L/min H/ 1764 1) NS 10; 25, Series

More information

Hydraulic Pump VP1-120

Hydraulic Pump VP1-120 REECHSROY GROUP REECHNOLOGY Bulgaria, Varna 9000 Industrial Zone Str. Studentska 1 U/UK1 odernization, complex repair and maintenance of heavy industrial equipment. Infrastructure construction and management

More information

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US Industrial Hydraulic Valves irectional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories Catalog HY14-25/US Industrial Hydraulic Valves WARNING USER RESPONSIBILITY FAILURE OR IMPROPER

More information

Proportional pressure reducing valve, 3-way variant, pilot operated

Proportional pressure reducing valve, 3-way variant, pilot operated roportional pressure reducing valve, 3-way variant, pilot operated RE 29286/1.1 Replaces: 2.8 1/14 ypes 3DRE(M) and 3DRE(M)E Sizes 1 and 16 Component series 7X Maximum pressure setting 315 bar (size 1)

More information

Proportional directional valve, pilot-operated, with integrated electronics (OBE)

Proportional directional valve, pilot-operated, with integrated electronics (OBE) Proportional directional valve, pilot-operated, with integrated electronics (OBE) Type WFCE RE 943 Edition: 7- Replaces: 6- Size 6 5 Component series X Maximum operating pressure 4 bar Maximum flow 5 l/min

More information

Directional Seat Valve Series D4S (Denison)

Directional Seat Valve Series D4S (Denison) Characteristics Seat valves series D4S are designed for directional control functions. A large variety of poppets, springs and covers - including shuttle valves, stroke limiters, solenoid valves (VV01)

More information

Proportional directional control valve, pilot operated with on-board electronics (OBE) and inductive position transducer

Proportional directional control valve, pilot operated with on-board electronics (OBE) and inductive position transducer Proportional directional control valve, pilot operated with on-board electronics (OBE) and inductive position transducer RE 29076/12.05 1/24 Type 4WRBKE Nominal size (NG) 10, 16, 27, 35 Unit series 1X

More information

2/2 Solenoid Cartridge Valve, Size 6

2/2 Solenoid Cartridge Valve, Size 6 / Solenoid Cartridge Valve, Size 6 Q max = l/min (.3 gpm), p max = 3 bar (4 psi) Bidirectional leak-proof shutoff, direct acting, with EX-safty solenoid coil Description Valve: Bidirectional leak-proof

More information

Q max (see specifications table)

Q max (see specifications table) 41 260/103 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVES EXPLOSION-PROOF VERSION EEx-dIIC SERIES 20 MD1K CETOP 03 E4P4K CETOP P05 E07P4K CETOP 07 E5P4K CETOP 08 E10P4K CETOP 10 p max (see specifications

More information

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS Table FX1-/E Replaces F6-5 /E E125-16 /E Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS Valve main body Cartridge Mechanical pressure limiter

More information

Chapter 6: Check Valves

Chapter 6: Check Valves Contents Chapter : Check Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 0 10 1 25 32 Subplate Screw-in Slip-in SSR RK / RB CS SPZBE SPV / SPZ C4V CPS C4V D4S

More information

Directional Controls

Directional Controls Vickers Directional Controls Wet Armature Solenoid Operated Directional Control Valves Model DGV-, Series Typical Construction of a Spring-Centered DC Valve with Variable Speed Pilot Control passage Speed

More information

Proportional pressure reducing valve of 3-way design Types 3DREP and 3DREPE

Proportional pressure reducing valve of 3-way design Types 3DREP and 3DREPE RE 29 184/12.02 Replaces: 12.98 roportional pressure reducing valve of 3-way design ypes 3DRE and 3DREE Nominal size 6 Series 2X Maximum operating pressure 100 bar Maximum flow 15 L/min H//D 5735/97 ype

More information

Q max 300 l/min. Fluid temperature range C Fluid viscosity range cst Recommended viscosity cst 25

Q max 300 l/min. Fluid temperature range C Fluid viscosity range cst Recommended viscosity cst 25 41 420/103 ED DSP7 PILOT OPERATED DISTRIBUTOR SOLENOID OR HYDRAULIC(DSC7) CONTROLLED SERIES 10 CETOP 07 p max (see performance ratings table) Q max 300 l/min MOUNTING INTERFACE CETOP 4.2-4-07-320 The DSP7

More information

4-way directional servo valve Type 4WS.2E

4-way directional servo valve Type 4WS.2E RE 29 91/06.02 Replaces: 03.93 4-way directional servo valve Type 4WS.2E Nominal size 16 Series 2X Maximum operating pressure 2/31 bar Maximum flow 3 L/min Overview of contents Contents Page Features 1

More information

Rexroth Hydraulics. Servo directional valve of 4-way design Type 4WS.2EM RE /03.99

Rexroth Hydraulics. Servo directional valve of 4-way design Type 4WS.2EM RE /03.99 RE 29 564/03.99 Replaces: 29 563 Servo directional valve of 4-way design ype 4WS.2EM Nominal size 6 Series 2X Maximum operating pressures 210 / 315 bar Maximum flow 40 L/min H//D 5994/98 ype 4WS2EM 6-2X/.E...K17EV

More information

Introduction. Pressure drops

Introduction. Pressure drops Directional control valves CETOP 5/NG0 Introduction The ARON directional control valves NG0 designed for subplate mounting with an interface in accordance with UNI ISO 440-05 - 04-0 - 94 standard (ex CETOP

More information

Gear Pumps / Motors. Series PGP / PGM Fixed Displacement Pumps, Cast-Iron and Aluminium Designs

Gear Pumps / Motors. Series PGP / PGM Fixed Displacement Pumps, Cast-Iron and Aluminium Designs Gear Pumps / Motors Series PGP / PGM Fixed Displacement Pumps, Cast-Iron and Aluminium Designs Table of contents Heavy-duty Pumps and Motors Series PGP, PGM Contents Page Series 500 Aluminium Table of

More information

Proportional pressure reducing valve of 3-way design

Proportional pressure reducing valve of 3-way design Courtesy of CM/Flodyne/Hydradyne Motion Control Hydraulic neumatic Electrical Mechanical (800) 426-5480 www.cmafh.com Electric Drives and Controls Hydraulics Linear Motion and ssembly echnologies neumatics

More information

Directional servo-valve of 4-way design

Directional servo-valve of 4-way design Courtesy of CM/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (0) 426-54 www.cmafh.com Directional servo-valve of 4-way design Type 4WSE3E 32 Size 32 Component series 5X Maximum

More information

Proportional pressure relief valve Types DBE(M) and DBE(M)E

Proportional pressure relief valve Types DBE(M) and DBE(M)E RE 29 142/02.99 Replaces: 06.97 Proportional pressure relief valve Types DE(M) and DE(M)E Nominal size 32 1) Series 3X Maximum operating pressure 3 bar Maximum flow 600 L/min H/ 1764 1) NS 10; 25, Series

More information

Stainless steel valves for water base fluids standard or ex-proof solenoid valves with Multicertification ATEX, IECEx, EAC or CULUS certification

Stainless steel valves for water base fluids standard or ex-proof solenoid valves with Multicertification ATEX, IECEx, EAC or CULUS certification www.atos.com Table TE137-1/E Stainless steel valves for water base fluids standard or ex-proof solenoid valves with Multicertification TEX, IECEx, EC or CULUS certification Ex-proof solenoid Valve body

More information

General Specifications DRV DRV-Exm DRV-Exd

General Specifications DRV DRV-Exm DRV-Exd direct operated, 3-way pressure reducing valve Q max = 8 l/min pressure range = - 5 bar body stainless steel (optional) Description The proportional pressure reducing valve (3-way function) is used to

More information

Sandwich Valves Series CP

Sandwich Valves Series CP Technical Information General Description. pilot operated check valves are designed for maximum flow rates. The valves are typically used in combination with spool type directional control valves to ensure

More information

Chapter 10: Valves for Pipe Mounting

Chapter 10: Valves for Pipe Mounting Contents Chapter : Valves for Pipe Mounting Series Description Size Body Page DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 1¼ 1½ 2 L-port T-port Pressure valves, manual operation R4V R4R Pressure relief function Pressure

More information

DL /118 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO p max 280 bar Q max 50 l/min

DL /118 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO p max 280 bar Q max 50 l/min 41 211/118 ED DL3 SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO 4401-03 p max 280 bar Q max 50 l/min MOUNTING SURFACE OPERATING PRINCIPLE ISO 4401-03-02-0-05 (CETOP

More information

p max (see table of performances) Q max (see table of performances) MD1K MD1KD bar

p max (see table of performances) Q max (see table of performances) MD1K MD1KD bar 41 510/107 ED EXLOSION-ROOF VERSION SOLENOID OERED DIRECIONL CONROL VLVES in compliance with EX 94/9/CE SERIES 21 MD1K-MD1KD ISO 4401-03 (CEO 03) E44K-E44KD CEO 05 E074K-E074KD ISO 4401-07 (CEO 07) E54K-

More information

3/2 and 4/2 directional seat valves with solenoid actuation

3/2 and 4/2 directional seat valves with solenoid actuation 1/16 3/ and 4/ directional seat valves with solenoid actuation RE 047-XH-B/01.10 Replaces: 09.07 ype E-.SE 6...XH ype W-.SE 6...XH Size 6 Component series 6X Maximum operating pressure 40 bar Maximum flow

More information

Servo solenoid valves with on-board electronics (OBE)

Servo solenoid valves with on-board electronics (OBE) Servo solenoid valves with on-board electronics (OBE) RE 29045/10.05 Replaces: 01.05 1/12 Type 5WRPE 10 Size 10 Unit series 2X Maximum working pressure P 1, P 2, A, B 210 bar, T 50 bar Nominal flow rate

More information

4/3 proportional directional control valve, without position control, with on-board electronics (OBE)

4/3 proportional directional control valve, without position control, with on-board electronics (OBE) 4/3 proportional directional control valve, without position control, with on-board electronics (OBE) Type 4WRBAE..E.. /..W.. Nominal size (NG) 6, 10 Unit series 2X Maximum working pressure P, A, B 315

More information

3/2 and 4/2 directional seat valves with solenoid actuation

3/2 and 4/2 directional seat valves with solenoid actuation 1/16 3/2 and 4/2 directional seat valves with solenoid actuation RE 22049-XN-B2/08.12 Replaces: 07.10 Type M-.SED 6...XN... Size 6 Component series 1X Maximum operating pressure 350 bar Maximum flow 25

More information

DFE. solenoid control monoblock valve. Content. Working conditions Hydraulic circuit DFE052. Dimensional data Ordering codes...

DFE. solenoid control monoblock valve. Content. Working conditions Hydraulic circuit DFE052. Dimensional data Ordering codes... DFE Content Working conditions... 54 Hydraulic circuit... 55 DFE52 DFE1 DFE2 Dimensional data... 6 Ordering codes... 64 Positioner kits... 67 Solenoid parts... 68 Dimensional data... 69 Ordering codes...

More information

Manapak Sandwich Valves. General Description

Manapak Sandwich Valves. General Description echnical Information Series RM General Description RM Series relief valves limit system pressure by opening to tank when system pressure reaches the valve setting. With D3 size, they can also be configured

More information

Proportional pressure relief valve, pilot operated

Proportional pressure relief valve, pilot operated Electric Drives and Controls Hydraulics Linear Motion and ssembly Technologies Pneumatics Service Proportional pressure relief valve, pilot operated R 29160/04.05 Replaces: 06.98 1/10 Model DE(M) and DE(M)E

More information

3-way Proportional pressure reducing valve, pilot operated

3-way Proportional pressure reducing valve, pilot operated 01/12 3-way roportional pressure reducing valve, pilot operated 6.6 ype 3DRE(M) and 3DRE(M)E Component series L6X NG 10 and 16 Max pressure 315 bar Max flow: 125L/min(size 10) 300L/min(size 16) Contents

More information

PRM7-04. Functional Description HA /2012. Proportional Directional Control Valves. Replaces HA /2009

PRM7-04. Functional Description HA /2012. Proportional Directional Control Valves. Replaces HA /2009 Proportional Directional Control Valves PRM7-6/ Size D () bar (6 PSI) L/min (. GPM ) Replaces /9 Digital control Compact design Operated by proportional solenoids High sensitivity and slight hysteresis

More information

4/2- and 4/3-way proportional directional valves, direct operated, without electrical position feedback, without/with integrated electronics (OBE)

4/2- and 4/3-way proportional directional valves, direct operated, without electrical position feedback, without/with integrated electronics (OBE) /- and /-way proptional directional valves, direct operated, without electrical position feedback, without/with integrated electronics (OE) Types WR and WRE Nominal sizes 6 and Component series X Maximum

More information

Directional Control Valves. Features. Application. Operation

Directional Control Valves. Features. Application. Operation Introduction pplication hydraulic directional control valves are high performance, solenoid controlled, pilot operated, 2-stage, 4-way valves. hey are available in 2 or 3-position styles and are manifold

More information

DXPE*J /117 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 31

DXPE*J /117 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 31 85 320/117 ED DXPE*J DIRECtIONL CONtROL VLVE PILOt OPERtED, WItH OE ND FEEDCK SUPLtE MOUNtINg DXPE5J CEtOP P05 DXPE5RJ ISO 4401-05 DXPE7J ISO 4401-07 DXPE8J ISO 4401-08 p max (see performance table) Q

More information

Proportional pressure reducing valve, pilot operated

Proportional pressure reducing valve, pilot operated Proportional pressure reducing valve, pilot operated Type DRE and DREE Sizes 10 and 25 1) Component series 6X Maximum operating pressure Maximum flow Table of contents Content 315 bar 300 l/min Page Features

More information

Proportional directional valves type DPZO-A* two stage without position transducer, ISO 4401 sizes 10, 16 and 25

Proportional directional valves type DPZO-A* two stage without position transducer, ISO 4401 sizes 10, 16 and 25 wwwatoscom Table F70-9/E Proportional directional valves type DPZO-* two stage out position transducer, ISO 0 sizes 0, 6 and 5 Communication plastic connector, see section 5 DPZO-E-5 DPZO-ES-PS-7 (dotted

More information

VED*HL-*-KD2 - HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES

VED*HL-*-KD2 - HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES CONTINENTAL HYDRAULICS VED*HL-*-KD2 HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES (IN COMPLIANCE WITH ATEX 94/4/EC) 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400 /

More information

Solenoid directional valves type DHAL8 and DHWL8 direct operated, ISO 4401 size 06, ex-proof or intrinsically safe, low leakage execution

Solenoid directional valves type DHAL8 and DHWL8 direct operated, ISO 4401 size 06, ex-proof or intrinsically safe, low leakage execution Table TEX5-/E Solenoid directional valves type DHL8 and DHWL8 direct operated, ISO 441 size 6, ex-proof or intrinsically safe, low leakage execution valve body spool ex-proof solenoid intrinsically safe

More information

Pressure Compensator Valves Series R5P (SAE Flange Mounted) General Description. Features

Pressure Compensator Valves Series R5P (SAE Flange Mounted) General Description. Features Technical Information General Description Series R5P direct operated, 3-way pressure compensators can be combined with any type of fixed or adjustable flow resistor (throttle) to provide a load compensated

More information

Servo solenoid valves with positive overlap and on-board electronics

Servo solenoid valves with positive overlap and on-board electronics Servo solenoid valves with positive overlap and on-board electronics RE 29089/01.05 1/22 Replaces: 05.04 Type 4WRLE 10...35, symbols E./W. Nominal size 10, 16, 25, 35 Unit series 3X Maximum working pressure

More information

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE) Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE) Type 4WRPE RE 29122 Edition: 2014-11 Size 10 Component series 3X Maximum operating pressure

More information

p max (see table of performances) Q max (see table of performances) bar Maximum flow rate from port P to A - B - T l/min

p max (see table of performances) Q max (see table of performances) bar Maximum flow rate from port P to A - B - T l/min 41 400/117 ED E*P4 PILOT OPERATED DISTRIBUTOR SOLENOID OR HYDRAULIC (C*P4) CONTROLLED E4P4 CETOP P05 E4R4 ISO 4401-05 E5 ISO 4401-08 p max (see table of performances) Q max (see table of performances)

More information

Sentronic PLUS 614 Series

Sentronic PLUS 614 Series Sentronic PLUS 64 Series Proportional Technology www.asco.com PRESSURE CONTROL: 64 SERIES SENTRONIC PLUS Sentronic PLUS Sentronic PLUS is a digitally operated pressure regulator valve. This valve accurately

More information

Proportional Throttle Valves Series TDL

Proportional Throttle Valves Series TDL Catalogue HY11-200/UK Characteristics Function Proportional throttle valves are designed to include three stages. The main valve poppet is controlled by a hydraulic follower. The position of the hydraulic

More information

Série D3 Válvula Direcional CETOP 5 e NG 10. Catálogo HY /US

Série D3 Válvula Direcional CETOP 5 e NG 10. Catálogo HY /US Série D3 Válvula Direcional CETOP 5 e NG 10 Catálogo HY14-2502/US Catalog HY14-2502/US Introduction pplication Series D3 hydraulic directional control valves are high performance, direct operated 4-way

More information

Directional Control Valves. General Description. Features. Specifications

Directional Control Valves. General Description. Features. Specifications Technical Information General Description directional control valves are high-performance, 4-chamber, direct operated, wet armature, solenoid controlled, 3 or 4-way valves. They are available in 2 or 3-position

More information

Directional Control Valves. Application. Features. Operation. D3W Solenoid Operated Conduit Cavity Style. D3W Solenoid Operated Hirschmann (DIN) Style

Directional Control Valves. Application. Features. Operation. D3W Solenoid Operated Conduit Cavity Style. D3W Solenoid Operated Hirschmann (DIN) Style Catalog HY14-2500/US Introduction pplication Series D3 hydraulic directional control valves are high performance, direct operated 4-way valves, available in 2 or 3-position. hey are manifold mounted which

More information

Proportional pressure reducing valve, in 3-way version

Proportional pressure reducing valve, in 3-way version roportional pressure reducing valve, in 3-way version RE 29184/06.11 Replaces: 12.02 1/12 ype 3DRE and 3DREE Size 6 Component series 2X Maximum operating pressure Maximum flow 100 bar 15 l/min able of

More information

Directional control valves, pilot-operated, with electrical position feedback and integrated electronics (OBE) Type 4WRTE. Features.

Directional control valves, pilot-operated, with electrical position feedback and integrated electronics (OBE) Type 4WRTE. Features. Directional control valves, pilot-operated, with electrical position feedback and integrated electronics (OBE) ype 4WRE RE 29083 Edition: 2017-03 Replaces: 08.13 Size 10 35 Component series 4X Maximum

More information

Proportional pressure reducing valves type DHRZO direct operated, ISO 4401 size 06

Proportional pressure reducing valves type DHRZO direct operated, ISO 4401 size 06 www.atos.com Table TF040-4/E Proportional pressure reducing valves type DHRZO direct operated, ISO 440 size 06 A DHRZO are 3 way, proportional pressure reducing valves, direct operated, with standard ISO

More information

4/2- and 4/3-way proportional directional valves, direct actuated, without electrical position feedback Types 4WRA and 4WRAE

4/2- and 4/3-way proportional directional valves, direct actuated, without electrical position feedback Types 4WRA and 4WRAE RE 29 0/08.0 Replaces: 06.00 /2- and /-way proptional directional valves, direct actuated, without electrical position feedback Types WR and WRE Nominal sizes 6 and Series 2X Maximum operating pressure

More information

Directional Control Valves. Application. Features. Operation

Directional Control Valves. Application. Features. Operation Catalog HY14-2500/US Introduction pplication Series D81 hydraulic directional control valves are high performance, solenoid controlled, pilot operated, 2-stage, 4-way valves. hey are available in 2 or

More information

RPE3-04. Functional Description HA /2013. Directional Control Valves Solenoid Operated. Replaces HA /2010

RPE3-04. Functional Description HA /2013. Directional Control Valves Solenoid Operated. Replaces HA /2010 Directional Control Valves Solenoid Operated RPE3-04 Size 04 (D 02) 320 bar (4600 PSI) 30 L/min (8.0 GPM) HA 4014 09/2013 Replaces HA 4014 10/2010 4/3-, 4/2- way directional control valves with solenoid

More information

3/3 servo directional control valve with mechanical position feedback

3/3 servo directional control valve with mechanical position feedback Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic neumatic Electrical Mechanical () 426-4 www.cmafh.com 3/3 servo directional control valve with mechanical position feedback Type 4WS2EM...XN...-114

More information