Chapter 3: Proportional DC Valves

Size: px
Start display at page:

Download "Chapter 3: Proportional DC Valves"

Transcription

1 Catalogue HY11-5/UK Contents Chapter : Proportional DC Valves Series Description Size Operation Electronics LVDT Spool Design Page DIN/ISO direct pilot external onboard Overlap Zero lap Spool/ Sleeve Introduction -2 Standard D1FB NG6 optional optional - D1FB OBE NG6 optional optional DFB NG1 optional -14 DFB OBE NG1 optional D1FB CANopen NG6 optional -24 DFB CANopen NG1 optional D1FB NG1-4 D1FB OBE NG1 D41FB NG16 D41FB OBE NG16 D91FB NG25 D91FB OBE NG25 D111FB NG2 D111FB OBE NG2 D1FV* Pilot Valve NG6-5 D1FV* OBE Pilot Valve NG6 High repeatability D1FH NG1-58 D41FH NG16 D81/91FH NG25 D111FH NG2 D1FE NG1-66 D41FE NG16 D81/91FE NG25 D111FE NG2 VCD performance*, for closed loop applications D1FP NG6-77 DFP NG1-8 DFP NG1-89 D1FP NG1-94 D41FP NG16 D91FP NG25 D111FP NG2 Accessories Plug-in connectors -14 Mounting patterns -15 * VCD = Voice Coil Drive technology Content.INDD RH

2 Catalogue HY11-5/UK Introduction Chapter : Proportional DC Valves Introduction: Proportional DC Valves Proportional valves and servo proportional valves are characterized by a number of design features that determine their quality to fit into different applications. The main features are listed below. Solenoid drive (proportional valves): Solenoids operate unidirectionally against a spring, provide high force and are - because of high inductance - limited in their dynamics. Voice Coil Drive : A moving coil in the field of a static permanent magnet operates bi-directionally. Springs are only needed to ensure the power-down position. The low inductance allows highest dynamics. External electronics: Valves without integrated electronics are less sensitive to vibration and high temperature. LVDTs always include integrated electronics. Integrated electronics (onboard electronics - OBE): Onboard electronics simplifies the installation and improves the repeatability from valve to valve. LVDT (spool position feedback): Closed loop control of the spool position improves the sensitivity and accuracy. Direct operated (d.o.): High hydraulic output can be achieved with low electric power input. Pilot operated (p.o.): Beyond the functional limits of direct operated valves hydraulic amplification is required. Positive spool overlap: To avoid load drifting in the zero position, spools with positive overlap are used. Zero lap spools: In closed loop circuits zero lap spools are used for an effective control of the spool at low position errors. Spool/Sleeve design: For minimal hysteresis, high precision, and better wear resistance, the spool/sleeve design is preferred over the spool/body design. Regenerative Valves: In applications with differential cylinders it is common to feed the return flow from the rod side of the cylinder back to the piston side to achieve higher velocity or lower pump flow. Parker differentiates between regeneration to the pressure level of the pump (P-regeneration) or directly to the piston area respectively the A-port of the valve (A-regeneration). The Parker regenerative valves use the advantageous A-regeneration. Hybrid Valves: Regenerative valves with an integrated solenoid valve - to switch to the standard mode - are called Hybrid Valves at Parker. The regenerative mode is used for maximum velocity, the standard mode for maximum force. Regenerative and hybrid valves are also available as on/off directional control valves. Intro.indd RH

3 Catalogue HY11-5/UK Characteristics Direct Operated Proportional DC Valve Series D1FB The proportional directional valves D1FB (NG6) are available with and without onboard electronics (OBE). D1FB OBE: The digital onboard electronics is situated in a robust metal housing, which allows the usage under rough environmental conditions. The nominal values are factory set. The cable connection to a serial RS22 interface is available as accessory. D1FB for external electronics: The parameters can be saved, changed and duplicated in combination with the digital power amplifier PWDA-4. The valve parameters can be edited with the common ProPxD software for both versions. The D1FB valves can be ordered with spool/sleeve design (D1FB*) for maximum precision as well as spool/body design (D1FB*) for high nominal flow - see functional limit curves for maximum flow capability. Valves with explosion proof solenoids EEx me ll see catalogue HY11-4. Download: - see Literature D1FB D1FB D1FB OBE D1FB OBE Technical Features Spool/sleeve and spool/body command options for D1FB OBE: +/- 1 V, 4 2 ma, +/- 2 ma High repeatability from valve to valve Low hysteresis Manual override Digital onboard electronics Zero lap spools for the usage of simple closed loop systems D1FB* OBE Spool/sleeve design D1FB* OBE Spool/body design Parametrizing connection Main connection (always on B-side) Manual override D1FB UK.indd RH

4 Catalogue HY11-5/UK Ordering Code Direct Operated Proportional DC Valve Series D1FB D1FB D 1 F B N Directional control valve Size DIN NG6 CETOP NFPA D Proportional control Standard dynamics standard repeatability Spool type Spool position Seals NBR (other seal compounds on request) Solenoid Connector Design Design series (not required for ordering) Code E1H E1F E1C E2H E2F E2C EH EF EC B1H B1F B2H B2F D1FB*: Spool/sleeve design Spool type Q B = Q A /2 Q B = Q A /2 Overlap Flow [l/min] at Dp 5 bar per metering edge / 1 12 / 6 2 / 1 12 / 6 Code Design Spool/sleeve design Spool/body design Code Connector W 2) Connector as per EN J 2)) Connector DT4-2P "Deutsch" D1FB*: Spool/sleeve design Code Solenoid M 9 V / 2.7 A J 24 V /.8 A Code E5H E5F E5C B6H B6F Code E1K E1H E1F E2K E2H E2F Zero lap 1) Flow [l/min] Spool type at Dp 5 bar per metering edge Q B = Q A /2 2 / 1 12 / 6 D1FB*: Spool/body design Overlap Flow [l/min] Spool type at Dp 5 bar per metering edge D1FB*: Spool/body design Code Solenoid K 12 V / 2.2 A J 24 V / 1.1 A Code Design C E K 1) Only for spool position code C. No defined spool positioning at power down. 2) Please order connector separately, see chapter accessories. ) Not for spool/sleeve design. D1FB UK.indd RH

5 Catalogue HY11-5/UK Ordering Code Direct Operated Proportional DC Valve Series D1FB OBE D1FB OBE (with onboard electronics) D 1 F B N Directional control valve Size DIN NG6 CETOP NFPA D Proportional control Standard dynamics standard repeatability Spool type Spool position Seals NBR (other seal compounds on request) Input signal Options Design Design series (not required for ordering) D1FB*: Spool/sleeve design Overlap Flow [l/min] Code Spool type at Dp 5 bar per metering edge E1H E1F E1C E2H E2F E2C EH EF EC B1H B1F Q B = Q A / / 1 12 / 6 Code Input signal ) Function Port Options F...+/-1 V...+1 V > P-A 6 + PE Potentiometer supply G...+/-2 ma...+2 ma > P-A 6 + PE S ma ma > P-A 6 + PE W5 2)...+/-1 V ma Code Design Spool/sleeve design Spool/body design Command...+1 V > P-A channel & 11 + PE ma > P-A potentiometer supply B2H B2F Q B = Q A /2 2 / 1 12 / 6 Code E5H E5F E5C B6H B6F Zero lap 1) Flow [l/min] Spool type at Dp 5 bar per metering edge Q B = Q A /2 2 / 1 12 / 6 Code C E K Design Code E1K E1H E1F E2K E2H E2F D1FB*: Spool/body design Overlap Flow [l/min] Spool type at Dp 5 bar per metering edge Please order connector separately, see chapter accessories. Parametrizing cable OBE RS22: Item no ) Only for spool position code C. No defined spool positioning at power down. 2) Factory set ± 1 V on delivery. ) Single solenoid always...+1 V respectively ma. D1FB UK.indd RH

6 Catalogue HY11-5/UK Technical Data Direct Operated Proportional DC Valve Series D1FB General Design Direct operated proportional DC valve Actuation Proportional solenoid Size NG6/CETOP /NFPA D Mounting interface DIN 244 / ISO 441 / CETOP RP121 / NFPA Mounting position unrestricted Ambient temperature [ C] MTTF D value (OBE) [years] 15 (75) Weight (OBE) [kg] 2.2 (2.9) Vibration resistance [g] 1 Sinus Hz acc. IEC Random noise Hz acc. IEC Shock acc. IEC Hydraulic Max. operating pressure [bar] Ports P, A, B 5; Port T 21 Max. pressure drop PABT / PBAT [bar] 5 Fluid Hydraulic oil as per DIN , other on request Fluid temperature [ C] Viscosity permitted [cst] / [mm 2 /s] recommended [cst] / [mm 2 /s] D1FB* (Spool/body) Filtration ISO 446 (1999) 18/16/1 Nominal flow at p = 5 bar D1FB* (Spool/sleeve) per control edge 1) [l/min] 6 / 12 / 2 1 / 2 / Leakage at 1 bar [ml/min] <5 (overlapped spool); <4 (zerolapped spool) <6 Overlap [%] 25, electrically normalized at 1 (see flow characteristics) Static / Dynamic Step response at 1 % step [ms] Hysteresis [%] <4 <6 Temperature drift solenoid current [%/K] <.2 Electrical characteristics Duty ratio [%] 1 ED; CAUTION: Coil temperature up to 15 C possible Standard (as per EN ) IP65 in accordance with EN 6529 (with correctly mounted Protection class plug-in connector) DT4-2P Deutsch IP69K (with correctly mounted plug-in connector) Solenoid Code "M" Code "K" Code "J" (Spool/sleeve) Supply voltage [V] Current consumption [A] (.8) Resistance [Ohm] Solenoid connection Connector as per EN (code W), DT4-2P Deutsch connector (code J). Solenoid identification as per ISO Wiring min. [mm²] x1.5 (AWG 16) overall braid shield (Code W), "Deutsch" connector DP4 2-Pin (Code J) Wiring lenght max. [m] 5 1) Flow rate for different p per control edge: Q x = Q Nom. p x p Nom. D1FB UK.indd RH

7 Catalogue HY11-5/UK Technical Data Direct Operated Proportional DC Valve Series D1FB OBE Electrical characteristics OBE Duty ratio [%] 1 ED; CAUTION: Coil temperature up to 15 C possible Protection class IP65 in accordance with EN 6529 (with correctly mounted plug-in connector) Supply voltage/ripple DC [V] 18..., ripple < 5 % eff., surge free Current consumption max. [A] 2. Pre fusing medium lag [A] 2.5 Input signal Codes F & W5 voltage [V] , ripple <.1 % eff., surge free, Ri = 1 kohm,...+1 V Þ P -> A Codes S & W5 current [ma] , ripple <.1 % eff., surge free, Ri = 2 Ohm, ma Þ P -> A <.6 ma = enable off, >.8 ma = enable on (acc. to NAMUR NE4) Code G [ma] , ripple <.1 % eff., surge free, Ri = 2 Ohm,...+2 ma Þ P -> A Differential input max. Codes F, G & S [V] for terminal D and E against PE (terminal G) 11 for terminal D and E against V (terminal B) Code W5 [V] for terminal 4 and 5 against PE (terminal PE) 11 for terminal 4 and 5 against V (terminal 2) Channel recall signal [V]...2.5: off / 5...: on / Ri = 1 kohm Adjustment ranges Min [%]...5 Max [%] Ramp [s] Interface RS 22, parametrizing connection 5pole EMC EN , EN Central connection Codes F, G & S Code W5 Wiring min. Codes F, G & S Code W5 [mm²] [mm²] Wiring length max PE acc. to EN PE acc. to EN x 1. (AWG16) overall braid shield 11 x 1. (AWG16) overall braid shield D1FB UK.indd RH

8 Catalogue HY11-5/UK Characteristic Curves Direct Operated Proportional DC Valve Series D1FB / D1FB OBE Flow characteristics D1FB* at p = 5 bar per metering edge Spool type E1/2/, B1/2 1 Spool type E* 1 Spool type B* Flow Q [% of nominal flow] P-B A-T P-A B-T Command signal [%] Flow Q [% of nominal flow] 75 A-T B-T 5 P-B P-A Command signal [%] D1FB* OBE (electrically set to opening point 1 %) at p = 5 bar per metering edge Spool type E1/2/, B1/2 Functional limits at 25 %, 5 %, 75 % and 1 % command signal (symmetric flow) Spool type E1H At asymmetric flow a reduced flow limit has to be considered typically approx. 1 % lower. All characteristic curves measured with HLP46 at 5 C. D1FB UK.indd RH

9 Catalogue HY11-5/UK Characteristic Curves Direct Operated Proportional DC Valve Series D1FB / D1FB OBE Flow characteristics D1FB* at p = 5 bar per metering edge Spool type E1/2 Flow Q [% of nominal flow] P-B A-T Spool type E* P-A B-T 25 D1FB* OBE (Electrically set to opening point 1 %) at p = 5 bar per metering edge Spool type E1/ Command signal [%] Functional limits at 25 %, 5 %, 75 % and 1 % command signal (symmetric flow) Spool type E1K At asymmetric flow a reduced flow limit has to be considered typically approx. 1 % lower. All characteristic curves measured with HLP46 at 5 C. D1FB UK.indd RH

10 Catalogue HY11-5/UK Block Diagrams Code F 6 + PE acc. to EN Direct Operated Proportional DC Valve Series D1FB OBE Code G, S 6 + PE acc. to EN Code W PE acc. to EN D1FB UK.indd RH

11 Catalogue HY11-5/UK Interface Program ProPxD interface program The ProPxD software permits comfortable parameter setting for the module electronics. Via the clearly arranged entry mask the parameters can be noticed and modified. Storage of complete parameter sets is possible as well as printout or record as a text file for further documentation. Stored parameter sets may be loaded anytime and transmitted to other valves. Inside the electronics a nonvolatile memory stores the data with the option for recalling or modification. The PC software can be downloaded free of charge at see page Support". Direct Operated Proportional DC Valve Series D1FB OBE Features Comfortable editing of all parameters Depiction and documentation of parameter sets Storage and loading of optimized parameter adjustments Executable with all actual Windows operating systems from Windows 95 upwards Plain communication between PC and electronics via serial interface RS-22 The parametrizing cable may be ordered under item no D1FB UK.indd RH

12 Catalogue HY11-5/UK Dimensions Direct Operated Proportional DC Valve Series D1FB D1FB*C D1FB*E D1FB*K D1FB*C* with DT4-2P "Deutsch" connector (only C style shown) D1FB*C* Surface finish NBR BK75 4x M5x ISO Nm ±15 % SK-D1FB D1FB UK.indd RH

13 Catalogue HY11-5/UK Dimensions Direct Operated Proportional DC Valve Series D1FB OBE D1FB*C OBE D1FB*E OBE D1FB*K OBE Surface finish NBR BK75 4x M5x ISO Nm ±15 % SK-D1FB D1FB UK.indd RH

14 Catalogue HY11-5/UK Characteristics Direct Operated Proportional DC Valve Series DFB The proportional directional valves DFB (NG1) are available with and without onboard electronics (OBE). DFB OBE: The digital onboard electronics is situated in a robust metal housing, which allows the usage under rough environmental conditions. The nominal values are factory set. The cable connection to a serial RS22 interface is available as accessory. DFB for external electronics: The parameters can be saved, changed and duplicated in combination with the digital power amplifier PWDA-4. The valve parameters can be edited with the common ProPxD software for both versions. The DFB valves can be ordered with spool/sleeve design (DFB*) for maximum precision as well as spool/body design (DFB*) for high nominal flow - see functional limit curves for maximum flow capability. DFB DFB OBE Technical Features Spool/sleeve and spool/body command options for DFB OBE: +/- 1 V, 4 2 ma, +/- 2 ma High repeatability from valve to valve Low hysteresis Manual override Digital onboard electronics DFB DFB OBE DFB* OBE Spool/sleeve design DFB* OBE Spool/body design Parametrizing connection Main connection (always on B-side) Manual override DFB UK.indd RH

15 Catalogue HY11-5/UK Ordering Code Direct Operated Proportional DC Valve Series DFB DFB D F B N W DC valve Size DIN NG1 CETOP 5 NFPA D5 Proportional control Standard dynamics standard repeatability Spool type Spool position Seal NBR (other seal compounds on request) Solenoid Connector as per EN without plug 1) Design Design series (not required for ordering) Code E1M E1S DFB*: Spool/sleeve design Spool type Flow [l/min] at Dp 5 bar per metering edge 4 6 Code Design Spool/sleeve design Spool/body design E2M E2S B1M B1S Q B = Q A / / 2 6 / DFB*: Spool/sleeve design Code Solenoid K 12 V / 2.95 A B2M B2S Code E1M E1S E1U E2M E2S E2U Q B = Q A /2 4 / 2 6 / DFB*: Spool/body design Flow [l/min] Spool type at Dp 5 bar per metering edge DFB*: Spool/body design Code Solenoid K 12 V / 2.95 A J 24 V / 1.5 A Code C E Design K For regenerative and hybrid function refer solution with sandwich and adaptor plates "A / A1-1665L / H / H1-1666L" in chapter 12. 1) Please order connector separately, see chapter accessories. DFB UK.indd RH

16 Catalogue HY11-5/UK Ordering Code Direct Operated Proportional DC Valve Series DFB OBE DFB OBE (with onboard electronics) D F B N Directional control valve Size DIN NG1 CETOP 5 NFPA D5 Proportional control Standard dynamics standard repeatability Spool type Spool position Seals NBR (other seal compounds on request) Input signal Options Design Design series (not required for ordering) Code E1M E1S DFB*: Spool/sleeve design Flow [l/min] Spool type at Dp 5 bar per metering edge 4 6 Code Design Spool/sleeve design Spool/body design E2M E2S B1M B1S B2M B2S Code E1M E1S E1U E2M E2S E2U Q B = Q A /2 Q B = Q A / / 2 6 / 4 / 2 6 / DFB*: Spool/body design Flow [l/min] Spool type at Dp 5 bar per metering edge Code Input signal 1) Function Port Options F...+/-1 V...+1 V > P-A 6 + PE Potentiometer supply G...+/-2 ma...+2 ma > P-A 6 + PE S ma ma > P-A 6 + PE W5 2)...+/-1 V ma Command...+1 V > P-A channel & 11 + PE ma > P-A potentiometer supply Code C Design E K For regenerative and hybrid function refer solution with sandwich and adaptor plates "A / A1-1665L / H / H1-1666L" in chapter 12. Please order connector separately, see chapter accessories. Parametrizing cable OBE RS22: Item no ) Single solenoid always...+1v respectively ma. 2) Factory set ± 1V on delivery. DFB UK.indd RH

17 Catalogue HY11-5/UK Technical Data Direct Operated Proportional DC Valve Series DFB General Design Direct operated proportional DC valve Actuation Proportional solenoid Size NG1 / CETOP 5 / NFPA D5 Mounting interface DIN 244 / ISO 441 / CETOP RP121 / NFPA Mounting position unrestricted Ambient temperature [ C] MTTF D value (OBE) [years] 15 (75) Weight (OBE) [kg] 6.5 (7.2) Vibration resistance [g] 1 Sinus Hz acc. IEC Random noise Hz acc. IEC Shock acc. IEC Hydraulic Max. operating pressure [bar] Ports P, A, B 5, T 21 Max. pressure drop PABT / PBAT [bar] 5 Fluid Hydraulic oil as per DIN , other on request Fluid temperature [ C] Viscosity permitted [cst] / [mm 2 /s] recommended [cst] / [mm 2 /s] Filtration ISO 446 (1999) 18/16/1 DFB* (Spool/sleeve) DFB* (Spool/body) Nominal flow at p=5 bar per control edge 1) [l/min] 4 / 6 4 / 6 / 8 Leakage at 1 bar [ml/min] <1 <1 Overlap 25, electrically normalized at 1 (see flow characteristics) Static / Dynamic Step response at 1 % step [ms] 4 Hysteresis [%] <4 <5 Temperature drift solenoid current [%/K] <.2 Electrical characteristics Duty ratio [%] 1 ED; CAUTION: Coil temperature up to 15 C possible Protection class IP 65 in accordance with EN 6529 (with correctly mounted plug-in connector) Solenoid Code K Code J Supply voltage [V] Current consumption [A] Resistance [Ohm] Solenoid connection Connector as per EN Wiring min. [mm²] x 1.5 recommended Wiring lenght max. [m] 5 recommended 1) Flow rate for different p per control edge: Q x = Q Nom. p x p Nom. DFB UK.indd RH

18 Catalogue HY11-5/UK Technical Data Direct Operated Proportional DC Valve Series DFB OBE Electrical characteristics OBE Duty ratio [%] 1 ED; CAUTION: coil temperatures up to 15 C possible! Protection class IP65 in accordance with EN 6529 (with correctly mounted plug-in connector) Supply voltage/ripple DC [V] 18..., ripple < 5 % eff., surge free Current consumption max. [A].5 Pre fusing medium lag [A] 4. Input signal Codes F & W5 voltage [V] , ripple <.1 % eff., surge free, Ri = 1 kohm,...+1 V Þ P -> A Codes S & W5 current [ma] , ripple <.1 % eff., surge free, Ri = 2 Ohm, ma Þ P -> A <.6 ma = enable off, >.8 ma = enable on (acc. to NAMUR NE4) Code G [ma] , ripple <.1 % eff., surge free, Ri = 2 Ohm,...+2 ma Þ P -> A Differential input max. Codes F, G & S [V] for terminal D and E against PE (terminal G) 11 for terminal D and E against V (terminal B) Code W5 [V] for terminal 4 and 5 against PE (terminal PE) 11 for terminal 4 and 5 against V (terminal 2) Channel recall signal [V]...2.5: off / 5...: on / Ri = 1 kohm Min [%]...5 Adjustment ranges Max [%] Ramp [s] Interface RS 22, parametrizing connection 5pole EMC EN , EN Central connection Codes F, G & S Code W5 Wiring min. Codes F, G & S Code W5 [mm²] [mm²] Wiring length max PE acc. to EN PE acc. to EN x 1. (AWG16) overall braid shield 11 x 1. (AWG16) overall braid shield DFB UK.indd RH

19 Catalogue HY11-5/UK Characteristic Curves Direct Operated Proportional DC Valve Series DFB Flow characteristics DFB at p = 5 bar per metering edge Flow Q [l% of nominal flow] P-B P-A Command signal [%] DFB OBE (Electrically set to opening point 1 %) at p = 5 bar per metering edge Spool type E1/2, B1/2 Flow Q [% of nominal flow] A-T Spool type B* P-A Flow Q [ % of nominal flow ] Spool type E* 25 P-B B-T 25 P-B A-T P-A B-T Command signal [%] Command signal [%] Functional limits 1 % command signal (symmetric flow). At asymmetric flow a reduced flow limit has to be considered. DFB* DFB* Flow Q [l/min] A B 1 P T 5 Spool type E1U Pressure drop p [bar] All characteristic curves measured with HLP46 at 5 C. DFB UK.indd RH

20 Catalogue HY11-5/UK Block Diagrams Code F 6 + PE acc. to EN Direct Operated Proportional DC Valve Series DFB OBE Code G, S 6 + PE acc. to EN Code W PE acc. to EN DFB UK.indd RH

21 Catalogue HY11-5/UK Interface Program ProPxD interface program The ProPxD software permits comfortable parameter setting for the module electronics. Via the clearly arranged entry mask the parameters can be noticed and modified. Storage of complete parameter sets is possible as well as printout or record as a text file for further documentation. Stored parameter sets may be loaded anytime and transmitted to other valves. Inside the electronics a nonvolatile memory stores the data with the option for recalling or modification. The PC software can be downloaded free of charge at see page Support". Direct Operated Proportional DC Valve Series DFB OBE Features Comfortable editing of all parameters Depiction and documentation of parameter sets Storage and loading of optimized parameter adjustments Executable with all actual Windows operating systems from Windows 95 upwards Plain communication between PC and electronics via serial interface RS-22 The parametrizing cable may be ordered under item no DFB UK.indd RH

22 Catalogue HY11-5/UK Dimensions Direct Operated Proportional DC Valve Series DFB DFB*C DFB*E DFB*K Surface finish BK85 4x M6x4 ISO Nm ±15 % NBR SK-DFB DFB UK.indd RH

23 Catalogue HY11-5/UK Dimensions Direct Operated Proportional DC Valve Series DFB OBE DFB*C OBE DFB*E OBE DFB*K OBE Surface finish BK85 4x M6x4 ISO Nm ±15 % NBR SK-DFB DFB UK.indd RH

24 Catalogue HY11-5/UK Characteristics Direct Operated Proportional DC Valve Series D*FB with CANopen The proportional directional valves D1FB (NG6) and DFB (NG1) with CANopen interface are based on the series for standard digital electronics of the same name. CANopen-Profile CANopen Application Layer and Communication Layer CiA DS - 1 Version 4.1 CANopen Layer Setting Services (LSS) and Protocols CiA DS 5 Version 2. Device Profile in accordance with CiA DSP 48 Version DFB*C D*FB*C The baud rate and node ID can be set by dip switches or Layer Setting Service (LSS). The valve parameters are factory set. Additionally the ProPxD software permits the editing of all parameters via the separate communication port. The software is also used for the valves with digital onboard electronics and the electronics modules. The cable for connection to a serial RS22 interface is available as accessory. The digital onboard electronics is situated in a robust metal housing and can be used in rough environments. The series D1FB and DFB are available with spool/ sleeve design as well as with spool/body design. DFB*C* Spool/sleeve design D*FB*E D*FB*K Technical Features CANopen interface Spool/sleeve design and spool/body design High repeatability from valve to valve Low hysteresis Manual override Failsafe center position Baud rate switch Node ID switch M12 female connection M12 male connection D1FB*C* Spool/sleeve design Parametrizing connection Supply voltage connection Manual override DFB*C* Spool/body design D_FB CANopen UK.indd RH

25 Catalogue HY11-5/UK Ordering Code Direct Operated Proportional DC Valve Series D*FB with CANopen D1FB D 1 F B N U Directional control valve Code E1H E1F E1C E2H E2F E2C EH EF EC B1H B1F B2H B2F Size DIN NG6 CETOP NFPA D Proportional control D1FB*: Spool/sleeve design Spool type Q B = Q A /2 Q B = Q A /2 Flow [l/min] at Dp 5 bar per metering edge / 1 12 / 6 2 / 1 12 / 6 Standard dynamics standard repeatability Spool type Spool position Seals NBR (other seal compounds on request) Communication interface CANopen DSP 48, 6+PE, 1xM12 male 1xM12 female Code C E K Options Design Design series (not required for ordering) Code Design Spool/sleeve design Spool/body design Spool position Code E1K E1H E1F E2K E2H E2F D1FB*: Spool/body design Flow [l/min] Spool type at Dp 5 bar per metering edge Please order connector separately, see chapter accessories. Parametrizing cable OBE RS22, Item no D_FB CANopen UK.indd RH

26 Catalogue HY11-5/UK Ordering Code Direct Operated Proportional DC Valve Series D*FB with CANopen DFB D F B N U Directional control valve Code E1M E1S E1U 1) E2M E2S E2U 1) Size DIN NG1 CETOP 5 NFPA D5 Spool type Proportional control Flow [l/min] at Dp 5 bar per metering edge Standard dynamics standard repeatability Spool type Spool position Seals NBR (other seal compounds on request) Communication interface CANopen DSP 48, 6+PE, 1xM12 male 1xM12 female Code Options Design Design series (not required for ordering) Code Design Spool/sleeve design Spool/body design Spool position B1M 2) B1S 2) Q B = Q A /2 4 / 2 6 / C B2M 2) B2S 2) Q B = Q A /2 4 / 2 6 / E K Please order connector separately, see chapter accessories. Parametrizing cable OBE RS22, Item no ) Only for Code Spool/sleeve design. 2) Only for Code Spool/body design. D_FB CANopen UK.indd RH

27 Catalogue HY11-5/UK Technical Data Direct Operated Proportional DC Valve Series D*FB with CANopen General Design Direct operated proportional DC valve Actuation Proportional solenoid Size NG6/CETOP /NFPA D NG1/CETOP 5/NFPA D5 Mounting interface DIN 244 / ISO 441 / CETOP RP121 / NFPA Mounting position unrestricted Ambient temperature [ C] MTTF D value [years] 75 Weight [kg] Vibration resistance [g] 1 Sinus Hz acc. IEC Random noise 2...2Hz acc. IEC Shock acc. IEC Hydraulic Max. operating pressure [bar] Ports P, A, B 5; Port T 21 Max. Pressure drop PABT / PBAT [bar] 5 Fluid Hydraulic oil as per DIN , other on request Fluid temperature [ C] Viscosity permitted recommended [cst]/[mm 2 /s] [cst]/[mm 2 /s] Filtration ISO 446 (1999) 18/16/1 D1FB* D1FB* DFB*/ Nominal flow at p=5bar per control edge 1) [l/min] 6 / 12 / 2 1 / 2 / 4 / 6 / 8 Leakage at 1 bar [ml/min] <5 <6 <1 Overlap [%] 25, electrically normalized at 1 (see flow characteristics) Static / Dynamic Step response at 1 % step [ms] 4 Hysteresis [%] <4 <6 <5 Temperature drift solenoid current [%/K] <.2 Electrical characteristics Duty ratio [%] 1; CAUTION: coil temperature up to 15 C possible Protection class IP65 in accordance with EN 6529 (with correctly mounted plug-in connector) Supply voltage/ripple DC [V] 18..., ripple < 5 % eff., surge free Current consumption max. [A] 2.. Pre fusing medium lag [A] EMC EN , EN Connection supply voltage 6 + PE acc. to EN Connection CANopen 1 x Male M12x1: 5p 1 x Female M12x1: 5p acc. to IEC Wiring supply voltage min. [mm 2 ] x 1. (AWG16) overall braid shield Wiring length supply voltage max. [m] 5 Wiring CANopen acc. to CiA DS-1 Version 4 / Twisted pair cable acc. to ISO11898 CANopen Profiles Communication Layer CIA DS - 1 version 2 Device Profile in accordance with CIA DS - 48 Version Layer Setting Service (LSS) CIA DS - 5 Version 2 Functionality CANopen slave One PDO (Receive) One PDO (Transmit) One SDO (not useable for valve parameterizing) Emergency object Sync object Node guarding Life guarding Heartbeat time (producer/consumer) Minimum boot - up Node - ID - adjustment by DIP switch and LSS Baud Rate - adjustment by DIP switch and LSS Parameterization Interface RS 22, parametrizing cable order code Interface program ProPxD (see Min [%]...5 Adjustment ranges Max [%] Ramp [s] ) Flow rate for different p per control edge: Q x = Q Nom. p x p Nom. D_FB CANopen UK.indd RH

28 Catalogue HY11-5/UK Characteristic Curves Direct Operated Proportional DC Valve Series D*FB with CANopen D1FB* flow characteristics at p = 5 bar per metering edge Flow Q [ % of nominal flow ] Spool type E* Flow Q [ % of nominal flow ] A-T Spool type B* P-A 25 P-B A-T P-A B-T 25 P-B B-T Command signal [%] Command signal [%] D1FB* flow limit at 25 %, 5 %, 75 % and 1 % command signal (symmetric flow). At asymmetric flow typically a lower flow limit has to be considered. Spool type E1H D1FB* flow characteristics at p = 5 bar per metering edge D1FB* flow limit at 25 %, 5 %, 75 % and 1 % command signal (symmetric flow). At asymmetric flow typically a lower flow limit has to be considered. Spool type E1K All characteristic curves measured with HLP46 at 5 C. D_FB CANopen UK.indd RH

29 Catalogue HY11-5/UK Characteristic Curves / Wiring Direct Operated Proportional DC Valve Series D*FB with CANopen DFB flow characteristics at p = 5 bar per metering edge Flow Q [ % of nominal flow ] Spool type E* Flow Q [% of nominal flow] A-T Spool type B* P-A 25 P-B A-T P-A B-T 25 P-B B-T Command signal [%] Flow limit 1 % command signal (symmetric flow). At asymmetric flow typically a lower flow limit has to be considered. DFB* DFB* Command signal [%] Flow Q [l/min] A B 1 P T 5 Spool type E1U Pressure drop p [bar] All characteristic curves measured with HLP46 at 5 C. Supply voltage connection 6 + PE A Supply voltage V B Supply voltage V C nc D nc E nc F nc G PE CANopen connection CAN in: M12, 5 pole male terminals. Pin 1: CAN_SHLD Pin 2: nc Pin : CAN_GND Pin 4: CAN_H Pin 5: CAN_L Shield is CAN_GND. CAN out: M12, 5 pole female terminals. Pin 1: CAN_SHLD Pin 2: nc Pin : CAN_GND Pin 4: CAN_H Pin 5: CAN_L Shield is CAN_GND. D_FB CANopen UK.indd RH

30 Catalogue HY11-5/UK Settings for CANopen Direct Operated Proportional DC Valve Series D*FB with CANopen Node ID adjustment with DIP switches DIP switch setting Node-ID LSS -priority OFF OFF OFF OFF OFF OFF 1 ON OFF OFF OFF OFF OFF 2 OFF ON OFF OFF OFF OFF ON ON OFF OFF OFF OFF 61 ON OFF ON ON ON ON 62 OFF ON ON ON ON ON 6 ON ON ON ON ON ON value Baud Rate adjustment with DIP switches Baud Rate DIP switch setting LSS -priority OFF OFF OFF 1 kbit/s ON OFF OFF 2 kbit/s OFF ON OFF 5 kbit/s ON ON OFF 125 kbit/s OFF OFF ON 25 kbit/s ON OFF ON 5 kbit/s OFF ON ON 1 MBit/s ON ON ON valve parameterization and diagnostics ON/OFF D_FB CANopen UK.indd RH

31 Catalogue HY11-5/UK Interface Program ProPxD interface program The ProPxD software permits comfortable parameter setting for the module electronics. Via the clearly arranged entry mask the parameters can be noticed and modified. Storage of complete parameter sets is possible as well as printout or record as a text file for further documentation. Stored parameter sets may be loaded anytime and transmitted to other valves. Inside the electronics a nonvolatile memory stores the data with the option for recalling or modification. The PC software can be downloaded free of charge at see page Support". Direct Operated Proportional DC Valve Series D*FB with CANopen Features Comfortable editing of all parameters Depiction and documentation of parameter sets Storage and loading of optimized parameter adjustments Executable with all actual Windows operating systems from Windows 95 upwards Plain communication between PC and electronics via serial interface RS-22 The parametrizing cable may be ordered under item no D_FB CANopen UK.indd RH

32 Catalogue HY11-5/UK Dimensions Direct Operated Proportional DC Valve Series D*FB with CANopen D1FB*C D1FB*E Surface finish NBR BK75 4x M5x ISO Nm ±15% SK-D1FB D_FB CANopen UK.indd RH

33 Catalogue HY11-5/UK Dimensions Direct Operated Proportional DC Valve Series D*FB with CANopen DFB*C DFB*E Surface finish NBR BK85 4x M6x4 ISO Nm ±15% SK-DFB D_FB CANopen UK.indd RH

34 Catalogue HY11-5/UK Characteristics The pilot operated proportional directional valves D*1FB are available in 4 sizes: D1FB - NG1 (CETOP 5) D41FB - NG16 (CETOP 7) D91FB - NG25 (CETOP 8) D111FB - NG2 (CETOP 1) The valves are available with and without onboard electronics (OBE). D*1FB OBE The digital onboard electronics is situated in a robust metal housing, which allows the usage under rough environmental conditions. The nominal values are factory set. The cable connection to a serial RS22 interface is available as accessory. D*1FB for external electronics The parameters can be saved, changed and duplicated in combination with the digital power amplifier PWDA-4. The valve parameters can be edited with the common ProPxD software for both versions. The D*1FB valves work with barometric feedback of the main stage to the pressure reducing pilot valve. The pilot control pressure of 25 bar allows high flow rates at maximum stability. The innovative integrated regenerative function into the A- line (optional) allows energy saving circuits for differential cylinders. The hybrid version can be switched between regenerative mode and standard mode at any time. Valves with explosion proof solenoids EEx me ll see catalogue HY11-4. Download: - see Literature D91FB OBE Pilot Operated Proportional DC Valve Series D*1FB D91FB OBE a A B P T A-regeneration D*1FBR OBE b a A B P T Standard D*1FB OBE a A B P T Hybrid D*1FBZ OBE Technical Features Progressive flow characteristics for sensitive adjustment of flow rate High flow capacity Digital onboard electronics optional Centre position monitoring optional Energy saving A-regeneration optional Switchable hybrid version optional Further literature about the opportunities of energy savings and more functional details of the integrated regeneration is available on request. b b Parametrizing connection Manual override Main connector (always on B-side of main stage) A B a b a b P X Y T D_1FB UK.indd RH

35 Catalogue HY11-5/UK Regenerative and Hybrid Function Pilot Operated Proportional DC Valve Series D*1FB D*1FBR and D*1FBZ Regenerative valve D*1FBR A B B A a b T A P B a b P X Y T A B Hybrid valve D*1FBZ a b B A a b T A P B P X Y T D*1FBR (regenerative valve) Cylinder extending D*1FBZ (hybrid valve) Cylinder extending regenerative mode (high speed) Cylinder extending standard mode (high force) A B A B A B QPump QPump Q Pump Q Regeneration Q Regeneration T P T P T P Flow rate in % of nominal flow Size 1) spool Port A-T P-A P-B B-A (R-valve) B-A (hybrid) B-T (hybrid) D41FBR/Z 1/2 1 % 5 % 1 % 5 % 45 % 2 % D91FBR/Z 1/2 1 % 5 % 1 % 5 % 5 % 25 % D111FBR/Z 1/2 1 % 5 % 1 % 5 % 5 % 2 % 1) D1FB: For size NG1 please refer solution with sandwich- and adaptor plates "A / A1-1665L / H / H1-1666L" in chapter 12. D_1FB UK.indd RH

36 Catalogue HY11-5/UK Ordering Code Pilot Operated Proportional DC Valve Series D*1FB D*1FB D 1 F B Directional control valve Code Size Nominal size NG6 pilot NG1 / CETOP 5 4 NG16 / CETOP 7 9 1) NG25 / CETOP 8 11 NG2 / CETOP 1 Proportional control Dynamics standard Function Flow Spool position Pilot connection Seal Solenoid description (other voltage on request) Electronic options Valve options Design series (not required for ordering) Valve options Code Standard 8 9) Monitor switch L 8) Hybrid valve 24 V normaly closed for spool type Z Code Standard Spool type NEW: Regenerative function 2) Code Spool type NEW: 2) ) Hybrid function Code Spool type Code Electronic options W 6) EN J 6) 7) DT4-2P "Deutsch" E1 E2 B1 Q B = Q A /2 R1 Z1 Code J K Solenoid voltage 24 V/1,1A 12 V/2,5A B2 Q B = Q A /2 R2 Z2 Code N V Seal NBR FPM Flow [l/min] Code at Dp = 5 bar per metering edge D1 D41 D91 D111 B 1 4) 5) C 75 5) 1 4) 5) D 9 5) E ) 5) F 2 - H 4 L 1 Code C Code Inlet Drain 1 Internal External 2 External External 4 Internal Internal 5 External Internal Design E 1) With enlarged connections Ø 2 mm. 2) For regenerative and hybrid function at D1FB (NG1) please refer solutions with sandwich- and adaptor plates "A / A1-1665L / H / H1-1666L" in chapter 12. A B A B D1FB spool type: R1 R2 T 1 P T 2 T 1 P T 2 ) Not for D1FB. 4) Not for spool type B1 und B2. 5) Not for regenerative and hybrid function. 6) Please order plugs separately. See accessories. 7) Not for hybrid function. 8) See page "regenerative and hybrid function" (not for D1FB). 9) Not for D111FBZ*. K D_1FB UK.indd RH

37 Catalogue HY11-5/UK Ordering Code Pilot Operated Proportional DC Valve Series D*1FB OBE D*1FB OBE D 1 F B Directional control valve Size NG6 pilot Code Nominal size NG1 / CETOP 5 4 NG16 / CETOP 7 9 1) NG25 / CETOP 8 11 NG2 / CETOP 1 Proportional control Onboard electronics Function Flow Spool position Pilot connection Seal Command signal Option Valve options Design series (not required for ordering) Code Valve options Standard 8 11) Monitor switch Hybrid valve 24V L 1) normaly closed for spool type Z Standard Code Spool type E1 E2 Q B = Q A /2 B1 Regenerative function 2) Code Spool type R1 2) ) Hybrid function Code Z1 Spool type Code Command signal 7) Function Connection 6) F 9)...±1 V...+1 V > P-B 6 + PE G 8)...±2 ma...+2 ma > P-B 6 + PE M 8) 9)...±1 V...+1 V > P-A 6 + PE S ma ma > P-A 6 + PE 8) 9)...±1 W5 V ma...+1 V > P-A 11 + PE ma > P-A B2 Q B = Q A /2 R2 Z2 Code N V Seal NBR FPM Flow [l/min] Code at Dp = 5 bar per metering edge D1 D41 D91 D111 B 1 4) 5) C 75 5) 1 4) 5) D 9 5) E ) 5) F 2 - H 4 L 1 Code C Code Inlet Drain 1 Internal External 2 External External 4 Internal Internal 5 External Internal Design Parametrizing cable OBE RS22, item no ) With enlarged connections Ø 2 mm. 2) For regenerative and hybrid function at D1FB (NG1) please refer solutions with sandwich- and adaptor plates "A / A1-1665L / H / H1-1666L" in chapter 12. A B A B D1FB spool type: R1, R2 T 1 P T 2 T 1 P T 2 ) Not for D1FB. 4) Not for spool type B1 und B2. 5) Not for regenerative and hybrid function. 6) Please order plugs seperately, see accessories. 7) For 1 solenoid...+1 V respectively ma. 8) Not for spool position E and K. 9) F, M potentiometer supply, W5 command channel & potentiometer supply. 1) See page "regenerative and hybrid function" (not for D1FB). 11) Not for D111FBZ*. E K D_1FB UK.indd RH

38 Catalogue HY11-5/UK Technical Data Pilot Operated Proportional DC Valve Series D*1FB General Design Pilot operated DC valve Actuation Proportional solenoid Size NG1 (CETOP 5) NG16 (CETOP 7) NG25 (CETOP 8) NG2 (CETOP 1) Mounting interface DIN 244 / ISO 441 / CETOP RP121 / NFPA Mounting position unrestricted Ambient temperature [ C] MTTF D value (OBE) [years] 75 (5) Weight (OBE) [kg] 8.6 (9.) 11.9 (12.6) 2.4 (21.1) 68 (68.7) Vibration resistance [g] 1 Sinus Hz acc. IEC Random noise Hz acc. IEC Shock acc. IEC Hydraulic Max. operating pressure [bar] Pilot drain internal: P, A, B, X 5; T, Y 185 (NG1: T, Y 15) [bar] Pilot drain external: P, A, B, T, X 5; Y 185 (NG1: Y 15) Fluid Hydraulic oil as per DIN , other on request Fluid temperature [ C] Viscosity permitted [cst] / [mm 2 /s] recommended [cst] / [mm 2 /s]...8 Filtration ISO 446 (1999) 18/16/1 Nominal flow at Dp=5 bar per control edge 1) [l/min] 75/9/12 1/2 25/4 1 Leakage at 1 bar [ml/min] Pilot supply pressure [bar] [bar] [bar] min. (+ T/Y pressure) max. 5 optimal dynamics at 5 Pilot flow at 1 bar [l/min] <.5 <1.2 <1.2 <1.2 Pilot flow, step response [l/min] Static / Dynamic Step response at 1 % step [ms] Hysteresis [%] <5 Electrical characteristics Duty ratio [%] 1 ED; CAUTION: Coil temperature up to 15 C possible Protection class Standard (as per EN1751-8) IP65 in accordance with EN 6529 DT4-2P "Deutsch" IP69K (with correctly mounted plug-in connector) Solenoid Code K J Supply voltage [V] Current consumption [A] Resistance [Ohm] Solenoid connection Connector as per EN (code W), DT4-2P "Deutsch" connector (code J). Solenoid identification as per ISO Wiring min. [mm²] x1.5 (AWG 16) overall braid shield Wiring lenght max. [m] 5 1) Flow rate for different p per control edge: Q x = Q Nom. p x p Nom. D_1FB UK.indd RH

39 Catalogue HY11-5/UK Technical Data / Characteristic Curves Pilot Operated Proportional DC Valve Series D*1FB Electrical characteristics (D*1FB OBE) Duty ratio [%] 1 ED; CAUTION: coil temperature up to 15 C possible Protection class IP65 in accordance with EN 6529 (with correctly mounted plug-in connector) Supply voltage/ripple DC [V] 18..., ripple < 5 % eff., surge free Current consumption max. [A] 2. Pre fusing medium lag [A] 2.5 Input signal voltage Codes F, M, W5 Code G [V] [V] , ripple <.1 % eff., surge free, Ri = 1 kohm , ripple <.1 % eff., surge free, Ri = 2 Ohm Codes S & W5 current [ma] , ripple <.1 % eff., surge free, Ri = 2 Ohm <.6 ma = enable off, >.8 ma = enable on (acc. to NAMUR NE4) Differential input max. Codes F, M G & S [V] [V] for terminal D and E against PE (terminal G) 11 for terminal D and E against V (terminal B) Code W5 [V] [V] for terminal 4 and 5 against PE (terminal PE) 11 for terminal 4 and 5 against V (terminal 2) Channel recall signal [V]...2.5: off / 5...: on / Ri = 1 kohm Adjustment ranges Min [%]...5 Max [%] Ramp [s] Interface RS 22, parametrizing connection 5pole EMC EN , EN Central connection Codes F, M G & S Code W5 Wiring min. Codes F, M G & S Code W5 [mm²] [mm²] Wiring length max PE acc. to EN PE acc. to EN x 1. (AWG16) overall braid shield 11 x 1. (AWG16) overall braid shield Electrical characteristics hybrid option Duty ratio [%] 1 ED; CAUTION: Coil temperature up to 15 C possible Protection class IP 65 in accordance with EN 6529 (with correctly mounted plug-in connector) D41 D91 D111 Supply voltage [V] Tolernace supply voltage [%] ±1 ±1 ±1 Current consumption [A] Power consumption [W] Solenoid connection Connector as per EN Wiring min. [mm²] x 1.5 recommended Wiring length max. [m] 5 recommended With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations. D*1FB B/E Flow characteristics at p = 5 bar per metering edge Spool code E1/2 Spool code B1/2* P-B P-A A-T B-T Command signal [%] All characteristic curves measured with HLP46 at 5 C. Flow [% of nominal flow] Flow [% of nominal flow] A-T P-A 1 P-B B-T Command signal [%] D_1FB UK.indd RH

40 Catalogue HY11-5/UK Characteristic Curves Pilot Operated Proportional DC Valve Series D*1FB D*1FB B/E OBE Flow characteristics (Electrically set to opening point 1 %) at p = 5 bar per metering edge Spool code E1/2 Spool code B1/2 Flow [% of nominal flow] Flow [% of nominal flow] P-B 1) P-A 1) A-T B-T Command signal [%] D*1FB R/Z (regenerative and hybrid) D41FB R/Z Spool code R/Z1/ P-B A-T P-A (R*, Z*) B-A (R*) 5% 4 4% B-A (Z*) 2 1 B-T 2% (Z*) Command signal [%] D41FB R/Z OBE Spool code R/Z1/2 Flow [% of nominal flow] Flow [% of nominal flow] P-B 1) A-T 1) P-A 1) B-T 1) Command signal [%] D91FB R/Z Spool code R/Z1/ P-B A-T B-T Command signal [%] D91FB R/Z OBE Spool code R/Z1/2 P-A, B-A 5% (R/Z*) 25% (Z*) Flow [% of nominal flow] P-B A-T P-A (R*, Z*) B-A (R*) B-A 5% 4% (Z*) 2 1 B-T 2% (Z*) Command signal [%] Flow [% of nominal flow] P-B A-T B-T Command signal [%] P-A, B-A 5% (R/Z*) 25% (Z*) All characteristic curves measured with HLP46 at 5 C. 1) Flow direction depending on ordering code. D_1FB UK.indd RH

41 Catalogue HY11-5/UK Monitor Switch Pilot Operated Proportional DC Valve Series D*1FB Monitor switch M12x1 pin assignment 1 + Supply V 2 output B (normally closed) V 4 output A (normally closed) 5 Earth ground Signal Output A (pin 4) Output B (pin 2) neutral closed closed The neutral position is monitored. The signal changes after less than 1 % of the spool stroke. open closed closed open Electrical monitor switch Protection class IP65 in accordance with EN 6529 (with correctly mounted plug-in connector) Ambient temperature [ C] -7 Supply voltage/ripple [V] , ripple < 1 % eff. Current consumption without load [ma] < Max. output current per channel, ohmic [ma] 4 Min. output load per channel, ohmic [kohm] 1 Max. output drop at.2 A [V] < 1.1 Max. output drop at.4 A [V] < 1.6 EMC EN61-6-2, EN Max. tol. ambient field strength [A/m] 12 Min. distance to next AC solenoid [m].1 Interface 4+PE acc. IEC (M12) Wiring min. [mm²] 5 x.5 (AWG 2) overall braid shield Wiring lenght max. [m] 5 D_1FB UK.indd RH

42 Catalogue HY11-5/UK Block Diagrams Code F, M 6 + PE acc. to EN Pilot Operated Proportional DC Valve Series D*1FB Code G, S 6 + PE acc. to EN Code W PE acc. to EN D_1FB UK.indd RH

43 Catalogue HY11-5/UK Interface Program ProPxD interface program The ProPxD software permits comfortable parameter setting for the module electronics. Via the clearly arranged entry mask the parameters can be noticed and modified. Storage of complete parameter sets is possible as well as printout or record as a text file for further documentation. Stored parameter sets may be loaded anytime and transmitted to other valves. Inside the electronics a nonvolatile memory stores the data with the option for recalling or modification. The PC software can be downloaded free of charge at see page Support". Pilot Operated Proportional DC Valve Series D*1FB Features Comfortable editing of all parameters Depiction and documentation of parameter sets Storage and loading of optimized parameter adjustments Executable with all actual Windows operating systems from Windows 95 upwards Plain communication between PC and electronics via serial interface RS-22 The parametrizing cable may be ordered under item no D_1FB UK.indd RH

44 Catalogue HY11-5/UK Pilot Flow Pilot Operated Proportional DC Valve Series D*1FB Pilot oil inlet (supply) and outlet (drain) open, closed A B Pilot oil Inlet Drain B C a b internal external external internal external D1FBB/E external internal internal D1FBR )( )( A P x y B C B T D41FBB/E D41FBR D41FBZ P T X Y X B 1/16"NPTF C M6 DIN96 B 1/16 NPTF B 1/16"NPTF C 1/16"NPTF C 1/16"NPTF P ( drawn offset) D91FBB/E D91FBR D91FBZ T ( drawn offset) D111FBB/E D111FBR D111FBZ D_1FB UK.indd RH

45 Catalogue HY11-5/UK Dimensions Pilot Operated Proportional DC Valve Series D*1FB D1FB Regenerative and hybrid function with additional plate "H1-1666L / H / A / A1-1665L", see chapter 12. Surface finish BK85 4x M6x4 ISO Nm ±15 % NBR: SK-D1FB FPM: SK-D1FB-V D41FB Surface finish BK2 2x M6x55 4x M1x6 ISO Nm ±15 % 6 Nm ±15 % NBR: SK-D41FB FPM: SK-D41FB-V D_1FB UK.indd RH

46 Catalogue HY11-5/UK Dimensions Pilot Operated Proportional DC Valve Series D*1FB D91FB Surface finish BK6 6x M12x75 ISO Nm ±15 % NBR: SK-D91FB FPM: SK-D91FB-V D111FB Surface finish BK86 6x M2x9 ISO Nm ±15 % NBR: SK-D111FB FPM: SK-D111FB-V D_1FB UK.indd RH

47 Catalogue HY11-5/UK Dimensions Pilot Operated Proportional DC Valve Series D*1FB Dimension with DT4-2P "Deutsch" Connector 67.5 B A 222 D_1FB UK.indd RH

48 Catalogue HY11-5/UK Dimensions Pilot Operated Proportional DC Valve Series D*1FB OBE D1FB OBE Regenerative and hybrid function with additional plate "H1-1666L / H / A / A1-1665L", see chapter 12. Surface finish BK85 4x M6x4 ISO Nm ±15 % NBR: SK-D1FB FPM: SK-D1FB-V D41FB OBE Surface finish BK2 2x M6x55 4x M1x6 ISO Nm ±15 % 6 Nm ±15 % NBR: SK-D41FB FPM: SK-D41FB-V D_1FB UK.indd RH

49 Catalogue HY11-5/UK Dimensions Pilot Operated Proportional DC Valve Series D*1FB OBE D91FB OBE Surface finish BK6 6x M12x75 ISO Nm ±15 % NBR: SK-D91FB FPM: SK-D91FB-V D111FB OBE Surface finish BK86 6x M2x9 ISO Nm ±15 % NBR: SK-D111FB FPM: SK-D111FB-V D_1FB UK.indd RH

50 Catalogue HY11-5/UK Characteristics Proportional Pressure Reducing Valve Series D1FV The proportional pressure reducing valves series D1FV are available with and without onboard electronics (OBE). D1FV OBE The digital onboard electronics is situated in a robust metal housing, which allows the usage under rough environmental conditions. The nominal values are factory set. The cable for connection to a serial RS22 interface is available as accessory. D1FV for external electronics The parameters can be saved, changed and duplicated in combination with the digital power amplifier PWDA-4. The value parameters can be edited with the common ProPxD software for both versions. The D1FV values control the pressure in the A- or B-ports using the barometric feedback principle. Valves with explosion proof solenoids EEx me ll see catalogue HY11-4. Download: - see Literature D1FV P a T P B B P T A A b T D1FV OBE T P a B P B P T A A T Technical Features Barometric feedback command options for D1FV OBE: ±1 V, ma, ±2 ma High repeatability from valve to valve Low hysteresis Manual override Pressure stages 25 bar and 45 bar Function C T P B P B P T A A b T Function E D1FV* OBE Function K Parametrizing connection Main connection (always on A-side) Manual override D1FV UK.indd RH

51 Catalogue HY11-5/UK Ordering Code Proportional Pressure Reducing Valve Series D1FV D1FV D 1 F V E2 K Proportional pressure reducing valve Size DIN NG6 CETOP NFPA D Proportional control Spool type Pressure range Control function Seals Solenoid Connector 12 V / 2.2 A Spool/ body design Design series (not required for ordering) Code C D Code Pressure range 25 bar 45 bar Control function Code Connector Connector as per W EN Connector J DT4-2P "Deutsch" C E Code N V Seals NBR FPM K D1FV OBE (with onboard electronics) D 1 F V E2 Directional control valve Size DIN NG6 CETOP NFPA D Proportional control Spool type Pressure range Control function Seals Input signal Electronic attachment Spool/ body design Design series (not required for ordering) Code C D Code C E Pressure range 25 bar 45 bar Control function Spool position Code Input signal 1) Function Port Options F...+/-1 V...+1 V > P-A 6 + PE Potentiometer supply G...+/-2 ma...+2 ma > P-A 6 + PE M...+/-1 V...+1 V > P-B 6 + PE Potentiometer supply S ma ma > P-A 6 + PE...+/-1 V...+1 V > P-A Command W5 2) ma channel & ma > P-A 11 + PE potentiometer...+/-2 ma...+2 ma > P-A supply K Code N V Seals NBR FPM Please order connector separately, see chapter accessories. Parametrizing cable OBE RS22, item no ) Single solenoid always...+1 V respectively ma. 2) Factory set ±1 V on delivery. D1FV UK.indd RH

52 Catalogue HY11-5/UK Technical Data Proportional Pressure Reducing Valve Series D1FV General Design Direct operated proportional pressure reducing valve Actuation Proportional solenoid Size NG6/CETOP /NFPA D Mounting interface DIN 244 / ISO 441 / CETOP RP121 / NFPA Mounting position unrestricted Ambient temperature [ C] MTTF D value (OBE) [years] 15 (75) Weight (OBE) [kg] 2.2 (2.9) Vibration resistance [g] 1 Sinus Hz acc. IEC Random noise Hz acc. IEC Shock acc. IEC Hydraulic Max. operating pressure [bar] Ports P, A, B 5; Port T 185 Max. pressure drop PABT / PBAT [bar] 5 Fluid Hydraulic oil as per DIN , other on request Fluid temperature [ C] Viscosity permitted [cst] / [mm 2 /s] recommended [cst] / [mm 2 /s] Filtration ISO 446 (1999) 18/16/1 Max. flow [l/min] 1 Min. primary pressure [bar] Static / Dynamic Hysteresis [%] <4 Temperature drift solenoid current [%/K] <.2 Electrical characteristics Duty ratio [%] 1 ED; CAUTION: coil temperature up to 15 C possible Protection class Standard (as per EN1751-8) IP65 in accordance with EN6529 (with correctly mounted plug-in connector); DT4-2P Deutsch IP69K (with correctly mounted plug-in connector) Supply voltage [V] 12 Current consumption [A] 2.2 Resistance [Ohm] 4.4 Solenoid connection Connector as per EN (code W), DT4-2P Deutsch connector (code J). Solenoid identification as per ISO Wiring min. [mm²] x1.5 (AWG 16) overall braid shield (code W), "Deutsch" connector DP4 2 Pin (code J) Wiring lenght max. [m] 5 recommended With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations. D1FV UK.indd RH

53 Catalogue HY11-5/UK Technical Data / Characteristic Curves Proportional Pressure Reducing Valve Series D1FV / D1FV OBE Electrical characteristics OBE Duty ratio [%] 1 ED; CAUTION: coil temperature up to 15 C possible Protection class IP65 in accordance with EN 6529 (plugged and mounted) Supply voltage/ripple DC [V] 18..., ripple < 5 % eff., surge free Current consumption max. [A] 2. Pre fusing medium lag [A] 2.5 Input signal Codes F & W5 voltage [V] , ripple <.1 % eff., surge free, Ri = 1 kohm,...+1 V Þ P -> A Codes M voltage [V] , ripple <.1 % eff., surge free, Ri = 1 kohm,...+1 V Þ P -> B Codes S & W5 current [ma] , ripple <.1 % eff., surge free, Ri = 2 Ohm, ma Þ P -> A <.6 ma = enable off, >.8 ma = enable on (acc. to NAMUR NE4) Code G [ma] , ripple <.1 % eff., surge free, Ri = 2 Ohm,...+2 ma Þ P -> A Differential input max. Codes F, G, M & S [V] for terminal D and E against PE (terminal G) 11 for terminal D and E against V (terminal B) Code W5 [V] for terminal 4 and 5 against PE (terminal PE) 11 for terminal 4 and 5 against V (terminal 2) Channel recall signal [V]...2.5: off / 5...: on / Ri = 1 kohm Min [%]...5 Adjustment ranges Max [%] Ramp [s] Interface RS 22, parametrizing connection 5pole EMC EN , EN Central connection Codes F, G, M & S Code W5 Wiring min. Codes F, G, M & S Code W5 [mm²] [mm²] Wiring length max PE acc. to EN PE acc. to EN x 1. (AWG16) overall braid shield 11 x 1. (AWG16) overall braid shield Flow characteristics Pressure drop p [bar] P-A / P-B A-T / B-T Flow [l/min] All characteristic curves measured with HLP46 at 5 C. D1FV UK.indd RH

54 Catalogue HY11-5/UK Block Diagrams Code F, M 6 + PE acc. to EN Proportional Pressure Reducing Valve Series D1FV OBE Code G, S 6 + PE acc. to EN Code W PE acc. to EN D1FV UK.indd RH

55 Catalogue HY11-5/UK Interface Program ProPxD interface program The ProPxD software permits comfortable parameter setting for the module electronics. Via the clearly arranged entry mask the parameters can be noticed and modified. Storage of complete parameter sets is possible as well as printout or record as a text file for further documentation. Stored parameter sets may be loaded anytime and transmitted to other valves. Inside the electronics a nonvolatile memory stores the data with the option for recalling or modification. The PC software can be downloaded free of charge at see page Support". Proportional Pressure Reducing Valve Series D1FV OBE Features Comfortable editing of all parameters Depiction and documentation of parameter sets Storage and loading of optimized parameter adjustments Executable with all actual Windows operating systems from Windows 95 upwards Plain communication between PC and electronics via serial interface RS-22 The parametrizing cable may be ordered under item no D1FV UK.indd RH

56 Catalogue HY11-5/UK Dimensions Proportional Pressure Reducing Valve Series D1FV D1FV*C D1FV*E D1FV*K D1FV*C with DT4-2P "Deutsch" connector (only C style shown) Surface finish NBR BK75 4x M5x ISO Nm ±15 % SK-D1FB D1FV UK.indd RH

57 Catalogue HY11-5/UK Dimensions Proportional Pressure Reducing Valve Series D1FV OBE D1FV*C OBE D1FV*E OBE D1FV*K OBE Surface finish NBR BK75 4x M5x ISO Nm ±15 % SK-D1FB D1FV UK.indd RH

58 Catalogue HY11-5/UK Characteristics The pilot operated proportional DC valves series D*1FH are high-performance valves with electronic spool position feedback. These valves are available in sizes NG1 to NG2 (CETOP 5 to CETOP 1). The D*1FH series is available in 5 sizes: D1FH NG1 (CETOP 5) D41FH NG16 (CETOP 7) D81FP NG25 (CETOP 8) for port diam. up to 26 mm D91FP NG25 (CETOP 8) for port diam. up to 2 mm D111FP NG2 (CETOP 1) Typical applications are: High precision and reproducible adjustment of flow rates, applications in rapid / creep speed with spool position monitoring for presses and dynamic position and p/q closed loop systems. Technical features Very low hysteresis High repeatability Spool position feedback Center position monitoring optional Pilot Operated Proportional DC Valve Series D*1FH D41FH D1FH D_1FH UK.indd RH

59 Catalogue HY11-5/UK Ordering Code Pilot Operated Proportional DC Valve Series D*1FH D 1 F H N Directional control valve Size NG6 pilot Proportional control High repeatability Spool type Flow Pilot connection Seal NBR (other seal compound on request) Command signal Electronic options Valve option Design series (not required for ordering) Code Size NG1 / CETOP 5 4 NG16 / CETOP 7 8 NG25 / CETOP 8 9 1) NG25 / CETOP 8 11 NG2 / CETOP 1 Code Spool type overlap E1 Code Valve option Standard 8 Monitor switch Code Signal Function B E S...±1 V standard...±2 ma ma...+1 V P -> B...+2 ma P -> B ma P -> A E2 B1 B2 Q B = Q A /2 Q B = Q A /2 Code Inlet Drain 1 Internal External 2 External External 4 Internal Internal 5 External Internal Flow [l/min] Code at Dp = 5 bar per metering edge D1 D41 D81 D91 D111 A 55 B 15 C 8 14 E F H L 1 Please order connector separately - see chapter accessories. 1) With enlarged connections Ø 2 mm. D_1FH UK.indd RH

60 Catalogue HY11-5/UK Technical Data Pilot Operated Proportional DC Valve Series D*1FH General Design Pilot operated DC valve with onboard electronics Actuation Proportional solenoid Size NG1 (CETOP 5) NG16 (CETOP 7) NG25 (CETOP 8) NG2 (CETOP 1) Mounting interface DIN 244 / ISO 441 / CETOP RP121 / NFPA Mounting position unrestricted Ambient temperature [ C] MTTF D value [years] 5 Weight [kg] Hydraulic Max. operating pressure [bar] Ports P, A, B, T, X 5; Port Y 1 Fluid Hydraulic oil as per DIN , other on request Fluid temperature [ C] Viscosity permitted [cst] / [mm 2 /s] recommended [cst] / [mm 2 /s]...8 Filtration ISO 446 (1999) 18/16/1 Nominal flow at p=5 bar per control edge 1) [l/min] 55/8 15/14/19/24 25/1/4 5/1 Leakage at 1 bar [ml/min] Pilot supply pressure [bar] 2-5 (optimal dynamics at 5) Pilot flow [l/min] <1.2 Pilot flow, step response [l/min] Static / Dynamic Step response at 1 % step [ms] Hysteresis [%] <.1 Sensitivity [%] <.5 Electrical characteristics Duty ratio [%] 1 Protection class IP65 in accordance with EN 6529 (with correctly mounted plug-in connector) Supply voltage/ripple [V] 18..., ripple <5 % eff., surge free Current consumption max. [A] 2. Input signal 2) Voltage Impedance Current Impedance Current Impedance Differential input max. Pre-fusing EMC Coil insulation class [V] , ripple <.1 % eff., surge free,...+1 V P >B [kohm] 1 [ma] , ripple <.1 % eff., surge free,...+2 ma P >B [Ohm] 5 [ma] , ripple <.1 % eff., surge free, ma P >A [Ohm] 5 [V] for terminal D and E against PE [A] 2.5 medium lag EN / EN582-2 F (155 C) Electrical connection 6+PE acc. EN Wiring min. [mm²] 7x1. (AWG 18) overall braid shield Wiring lenght max. [m] 5 1) Flow rate for different p per control edge: 2) Inverse polarity on request Q x = Q Nom. p x p Nom. D_1FH UK.indd RH

61 Catalogue HY11-5/UK Electronics Control system flow chart, valve electronics Pilot Operated Proportional DC Valve Series D*1FH Wiring Enable input The power stage is activated via pin C (enable input). Arrangement of the potentiometers Supply voltage monitoring If the minimal supply voltage drops below, it is internally monitored and displayed via the status LED. Control monitoring A control error is indicated if there is an error in the control circuit of the valve. Spindle trimmer for zero point compensation Display is green Display off Normal operation Supply voltage is outside the permissible range of V LED Diagnostics for spool stroke Display is red Control error D_1FH UK.indd RH

62 Catalogue HY11-5/UK Flow Characteristic / Monitor Switch Flow characteristics at p = 5 bar per metering edge Spool types E1, E2 Pilot Operated Proportional DC Valve Series D*1FH Spool types B1, B2 All characteristic curves measured with HLP46 at 5 C. Electrical monitor switch Electrical monitor switch Protection class IP65 in accordance with EN 6529 (with correctly mounted plug-in connector) Ambient temperature [ C] -7 Supply voltage/ripple [V] , ripple <1 % eff. Current consumption without load [ma] < Max. output current per channel, ohmic [ma] 4 Min. output load per channel, ohmic [kohm] 1 Max. output drop at.2 A [V] <1.1 Max. output drop at.4 A [V] <1.6 EMC EN / EN582-2 Max. tol. ambient field strength [A/m] 12 Min. distance to next AC solenoid [m].1 Interface 4+PE acc. IEC (M12) Wiring min. [mm²] 4x.5 (AWG 2) overall braid shield Wiring lenght max. [m] 5 Monitor switch M12x1 pin assignment 1 + Supply V 2 output B (normally closed) V 4 output A (normally closed) 5 Earth ground Signal Output A (pin 4) Output B (pin 2) neutral closed closed The neutral position is monitored. The signal changes after less than 1 % of the spool stroke. open closed closed open D_1FH UK.indd RH

63 Catalogue HY11-5/UK Pilot Flow Pilot Operated Proportional DC Valve Series D*1FH Pilot oil inlet (supply) and outlet (drain) a A B b A )( )( B P x y B C T D1FH D41FH D81/91FH D111FH D_1FH UK.indd RH

64 Catalogue HY11-5/UK Dimensions Pilot Operated Proportional DC Valve Series D*1FH D1FH Surface finish NBR BK85 4x M6x4 ISO Nm ±15 % SK-D1FHN D41FH Surface finish BK2 2x M6x55 4x M1x6 ISO Nm ±15 % 6 Nm ±15 % NBR SK-D41FHN D_1FH UK.indd RH

65 Catalogue HY11-5/UK Dimensions Pilot Operated Proportional DC Valve Series D*1FH D81/91FH Surface finish NBR BK6 6x M12x75 ISO Nm ±15 % SK-D91FHN D111FH Surface finish NBR BK86 6x M2x9 ISO Nm ±15 % SK-D111FHN D_1FH UK.indd RH

66 Catalogue HY11-5/UK Characteristics Pilot Operated Proportional DC Valve Series D*1FE The series of pilot operated proportional valves D*1FE is designed for high precision applications that require a safe middle position of the main spool at power down. The pilot is a -position valve with an overlapped middle position. This ensures that the main stage spring pushes the spool into the middle position at power down without an unintended jerk of the actuator. The D*1FE series is available in 5 sizes: D1FE NG1 (CETOP 5) D41FE NG16 (CETOP 7) D81FE NG25 (CETOP 8) for port diam. up to 26 mm D91FE NG25 (CETOP 8) for port diam. up to 2 mm D111FE NG2 (CETOP 1) The innovative integrated regenerative function in the A-line (optional) allows new energy saving circuits with differential cylinders. The hybrid version can switch between regenerative mode and standard mode at any time. D41FE Standard A B a b P T G G A B a b P T Standard D*1FE A B a b P T G G G G Technical features High dynamics High flow Defined spool positioning at power-down Onboard electronics Centre position monitoring optional Energy saving A-regeneration optionally integrated Switchable hybrid version A-regeneration D*1FER Hybrid D*1FEZ Further literature about the opportunities of energy savings and more functional details of the integrated regeneration is available on request. D41FEE1 (Standard) A B G a b a b G P X Y T D_1FE UK.indd RH

67 Catalogue HY11-5/UK Regenerative and Hybrid function Pilot Operated Proportional DC Valve Series D*1FE D*1FER and D*1FEZ Regenerative valve D*1FER Hybrid valve D*1FEZ D*1FER (regenerative valve) Cylinder extending D*1FEZ (hybrid valve) Cylinder extending in regenerative mode (high speed) Cylinder extending in standard mode (high force) A B A B A B QPump Q Regeneration QPump Q Regeneration Q Pump T P T P T P Flow rate in % of nominal flow Port Size 1) Spool A-T P-A P-B B-A (R-Valve) B-A (Hybrid) B-T (Hybrid) D41FER/Z 1/2 1 % 5 % 1 % 5 % 4 % 2 % D91FER/Z 1/2 1 % 5 % 1 % 5 % 5 % 25 % D111FER/Z 1/2 on request 1) D1FE: For size NG1 please refer solution with sandwich- and adaptor plates "A / A1-1665L / H / H1-1666L" in chapter 12. D_1FE UK.indd RH

68 Catalogue HY11-5/UK Ordering Code Pilot Operated Proportional DC Valve Series D*1FE D 1 F E C Directional control valve Size NG6 pilot Proportional control High repeatability Function Flow Spool Pilot position connections on power down Seals Command signal Electronic options Valve option Design series (not required for ordering) Code Size NG1 / CETOP 5 4 NG16 / CETOP 7 8 NG25 / CETOP 8 9 1) NG25 / CETOP 8 11 NG2 / CETOP 1 Code Valve option Standard for spool code B, E, R 8 6) Monitor switch Hybrid valve 24 V L 5) normaly closed for spool code Z Standard Code Spool type overlap 1 % E1 NEW: regenerative 2) ) function Code Spool type overlap 1 % R1 NEW: hybrid ) 4) function Code Spool type overlap 1 % Z1 Code Electronic options 6+PE acc. EN PE acc. 5 EN PE + Enable E2 B1 B2 Q B = Q A /2 Q B = Q A /2 R2 Z2 Code Signal Function B...±1 V...+1 V P -> B E...+2 ma...±2 ma P -> B K...±1 V...+1 V P -> A S ma ma P -> A Flow [l/min] Code at Dp = 5 bar per metering edge D1 D41 D81 D91 D111 D 9 E 12 F 2 H 4 45 L 1 Code Seals N NBR V FPM H for HFC fluid Code Inlet Drain 1 internal external 2 external external 4 internal internal 5 external internal 1) For enlarged connections Ø 2 mm. 2) Not for D81FE. ) For regenerative and hybrid function at D1FE (NG1) please refer to solutions with sandwich and adaptor plates "A / A1-1665L / H / H1-1666L" in chapter 12. A B A B D1FE spooltype: R1, R2 T 1 P T 2 T 1 P T 2 4) Not for D1FE and D81FE. 5) See page "Regenerative and hybrid function" (not for D1FE). 6) Not for D111FEZ. Please order connector separately. See chapter accessories. D_1FE UK.indd RH

69 Catalogue HY11-5/UK Technical Data Pilot Operated Proportional DC Valve Series D*1FE General Design Proportional directional control valve, pilot operated Actuation VCD -actuator Size NG1 (CETOP 5) NG16 (CETOP 7) NG25 (CETOP 8) NG2 (CETOP 1) D1 D41 D81 / D91 D111 Mounting Interface DIN 244 / ISO 441 / CETOP RP121 / NFPA Mounting position unrestricted Ambient temperature [ C] MTTF D value [years] 5 Weight [kg] Vibration resistance [g] 1 Sinus Hz acc. IEC Random noise Hz acc. IEC Shock acc. IEC Hydraulic Max. operating pressure [bar] Internal pilot drain P, A, B, X 5; T, Y 5 External pilot drain P, A, B, T, X 5; Y 5 Fluid Hydraulic oil acc. DIN , other on request Fluid temperature [ C] Viscosity permitted [cst] / [mm2/s] recommended [cst] / [mm2/s]...8 Filtration ISO 446 (1999) 18/16/1 Nominal flow at Dp = 5 bar per control edge 1) [l/min] /45 1 Max. recommended Flow (Standard) [l/min] Regenerative B-A / B-T depending on application, see flow curves Leakage at 1 bar [ml/min] Pilot [ml/min] < 1 Pilot supply pressure [bar] Pilot flow, during step response at 21 bar [l/min] Static / Dynamic Step response at 1% stroke 2) [ms] Frequency response Amplitude ±5 % at 21 bar Phase ±5 % at 21 bar [Hz] [Hz] Hysteresis [%] <.1 Sensitivity [%] <.5 Temperature drift of Center Position [%/K] <.25 Electrical Duty ratio [%] Protection class IP65 in accordance with EN 6529 (with correctly mounted plug-in connector) Supply voltage / ripple [V] 22..., ripple < 5 % eff., surge free Current consumption max. [A].5 Pre-fusing [A] 4. A medium lag Input signal Code K (B) Voltage Impedance [V] [kohm] , ripple <.1 % eff., surge free,...+1 V P >A (P >B) 1 Code E Voltage Impedance [ma] [Ohm] , ripple <.1 % eff., surge free,...+2 ma P >B 25 Code S Current Impedance [ma] [Ohm] , ripple <.1 % eff., surge free, ma P >A 25 <.6 ma = enable off, >.8 ma = enable on acc. NAMUR NE4 Input Capacitance typ. [nf] 1 Differential input max. Code [V] for terminal D and E against PE (terminal G) 11 for terminal D and E against V (terminal B) Code 5 [V] for terminal 4 and 5 against PE (terminal W ) 11 for terminal 4 and 5 against V (terminal 2) Code 7 [V] for terminal D and E against PE (terminal G) Enable signal Code 5/7 [V] 5..., Ri = 9 kohm Diagnostic signal [V] / +Ub, rated max. 5 ma EMC EN , EN Electrical connection Code /7 6 + PE acc. EN Code PE acc. EN Wiring min. Code /7 7 x 1. AWG16 overall braid shield Code 5 8 x 1. AWG16 overall braid shield Wiring lenght max. [m] ) Flow rate for different p per control edge: p x Q x = Q Nom. 2) Measured with load (21 bar pressure drop/two control edges). p Nom. D_1FE UK.indd RH

70 Catalogue HY11-5/UK Monitor Switch Pilot Operated Proportional DC Valve Series D*1FE Monitor switch M12x1 pin assignment 1 + Supply V 2 output B (normally closed) V 4 output A (normally closed) 5 Earth ground Signal Output A (pin 4) Output B (pin 2) neutral closed closed The neutral position is monitored. The signal changes after less than 1 % of the spool stroke. open closed closed open Electrical monitor switch Protection class IP65 in accordance with EN 6529 (with correctly mounted plug-in connector) Ambient temperature [ C] -7 Supply voltage/ripple [V] , ripple < 1 % eff. Current consumption without load [ma] < Max. output current per channel, ohmic [ma] 4 Min. output load per channel, ohmic [kohm] 1 Max. output drop at.2 A [V] < 1.1 Max. output drop at.4 A [V] < 1.6 EMC EN61-6-2, EN Max. tol. ambient field strength [A/m] 12 Min. distance to next AC solenoid [m].1 Interface 4+PE acc. IEC (M12) Wiring min. [mm²] 5x.5 (AWG 2) overall braid shield Wiring lenght max. [m] 5 D_1FE UK.indd RH

71 Catalogue HY11-5/UK Technical Data / Electronics Pilot Operated Proportional DC Valve Series D*1FE Electrical characteristics hybrid option Duty ratio 1 % Protection class IP 65 in accordance with EN 6529 (with correctly mounted plug-in connector) D41 D91 D111 Supply voltage [V] Tolerance supply voltage [%] ±1 ±1 ±1 Current consumption [A] Power consumption [W] Solenoid connection Connector as per EN Wiring min. [mm²] x 1.5 recommended Wiring length max. [m] 5 recommended With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations. Wiring Code, 6 + PE acc. EN Power supply ~ Code 5, 11 + PE acc. EN Command...±1V 4...2mA 5...V...±2mA o + Diagnostics valve stroke...±1v V F E A G D B C + 24V = o Enable o 24V + ~ V Diagnostics valve stroke...±1v...±1v 4...2mA...±2mA Command Code 7, 6 + PE acc. EN enable Power supply = Power supply Pin and 8 internally connected Pin 9 and 11 internally connected Pin 1 n.c. ~ = Diagnostics valve stroke...±1v V F E A G D B C + 24V o D_1FE UK.indd RH Enable + o...±1v 4...2mA...±2mA Command 5...V -71

72 Catalogue HY11-5/UK Characteristic Curves Frequency response ±5 % / ±25 % / ±9 % command signal Dynamics at 21 bar pilot supply pressure D1FE Pilot Operated Proportional DC Valve Series D*1FE D41FE D81/91FE D111FE Flow curves D*1FEB/E at Dp = 5 bar per metering edge D1FE spool type E1/2, B1/2 Flow Q [% of nominal flow] P-B A-T P-B P-A B-T B-T (E*) 5% (B*) D41FE spool type E1/2, B1/2 Flow Q [% of nominal flow] P-B A-T P-B P-A B-T B-T (E*) 5% (B*) Command signal [%] Command signal [%] All characteristic curves measured with HLP46 at 5 C. D_1FE UK.indd RH

73 Catalogue HY11-5/UK Characteristic Curves Flow curves D81/91FE Spool type E1/2, B1/2 Pilot Operated Proportional DC Valve Series D*1FE D111FE Spool type E1/2, B1/2 Flow Q [% of nominal flow] P-B A-T P-B P-A B-T B-T (E*) 5% (B*) Flow Q [% of nominal flow] P-B A-T P-B P-A B-T B-T (E*) 5% (B*) Command signal [%] Command signal [%] D*1FER/Z at Dp = 5 bar per metering edge D1FE spool type R1/2 D41FE spool type R/Z1/2 D91FE Spool type R/Z1/2 D111FE Spool type R/Z* on request All characteristic curves measured with HLP46 at 5 C. D_1FE UK.indd RH

74 Catalogue HY11-5/UK Pilot Flow Pilot Operated Proportional DC Valve Series D*1FE Pilot oil inlet (supply) and outlet (drain) open, closed Pilot oil Inlet Drain B C internal external a A B b G external internal external external internal internal a b G D1FEB/E P B D1FER x y C T D41FEB/E D41FER D41FEZ P T X Y X B 1/16"NPTF C M6 DIN96 B 1/16 NPTF B 1/16"NPTF C 1/16"NPTF C 1/16"NPTF (drawn offset) P (drawn offset) T D81/91FEB/E D91FER D91FEZ D111FEB/E D111FER D111FEZ D_1FE UK.indd RH

75 Catalogue HY11-5/UK Dimensions Pilot Operated Proportional DC Valve Series D*1FE D1FE Regenerative and hybrid function with additional plate "A / A1-1665L / H / H1-1666L", see chapter 12. Surface finish BK85 4x M6x4 ISO Nm ±15 % NBR: SK-D1FP FPM: SK-D1FP-V D41FE Surface finish BK2 2x M6x55 4x M6x6 ISO Nm ±15 % 6 Nm ±15 % NBR: SK-D41FP FPM: SK-D41FP-V D_1FE UK.indd RH

76 Catalogue HY11-5/UK Dimensions Pilot Operated Proportional DC Valve Series D*1FE D81/91FE Surface finish BK6 6x M12x75 ISO Nm ±15 % NBR: SK-D81/D91FP FPM: SK-D81/D91FP-V D111FE Surface finish BK86 6x M2x9 ISO Nm ±15 % NBR: SK-D111FP FPM: SK-D111FP-V D_1FE UK.indd RH

77 Catalogue HY11-5/UK Characteristics Direct Operated Proportional DC Valve Series D1FP The direct operated control valve D1FP of the nominal size NG6 (CETOP ) shows extremly high dynamics combined with maximum flow. It is the preferred choice for highest accuracy in positioning of hydraulic axis and controlling of pressure and velocity. Driven by the patented VCD actuator the D1FP reaches the frequency response of real servovalves. Compared with solenoid driven valves the D1FP can also be used in applications with pressure drops up to 5 bar across the valve. Because of the high flow capability the D1FP can be a substitute for NG1 valves in some cases. At power-down the spool moves in a defined position. All common input signals are available. Technical features Real servovalve dynamics (- db / 5 Hz at ±5 % input signal) No flow limit up to 5 bar pressure drop through the valve Max. tank pressure 5 bar (with external drain port y) High flow Defined spool positioning at power-down - optional P-A/B-T or P-B/A-T or center position (for overlapped spools) Onboard electronics D1FP UK.indd RH

78 Catalogue HY11-5/UK Ordering Code Direct Operated Proportional DC Valve Series D1FP D 1 F P 9 Directional control valve Size DIN NG6 CETOP NFPA D Proportional control VCD Spool type Spool position on power down 1) Y-port (plugged) 5) Seals Command signal Accessories Spool/ sleeve design Design series (not required for ordering) Code E5M E5H E5G E5F E5C E5B B6M B6H B6G B6F B6C E55M E55H E55G E55F E55C E55B E1M E1H E1G E1F E1C E1B B1M B1H B1G B1F B1C E2M E2H E2G E2F E2C E2B B2M B2H B2G B2F B2C Flow [l/min] Spool type at p 5 bar per metering edge Zerolap / 2 Q B = Q A /2 25 / / 8 12 / 6 6 / Underlap approx. -.5 % Overlap 25 % / 2 Q B = Q A /2 25 / / 8 12 / 6 6 / / 2 Q B = Q A /2 25 / / 8 12 / 6 6 / Code Connection type 6 + PE acc. EN PE 5 acc. EN PE + Enable Code Signal Function B +/- 1 V...+1 V -> P-A E +/- 2 ma...+2 ma -> P-A S ma ma -> P-A Code A 2) B 2) C ) Code N V H A Seals NBR FPM for HFC fluid Spool position at power down B H 4) a b P A T B J 4) a b P T Note: Adapter plate for ISO 441 to ISO 172 size 4 Ordering code HAP4WV Please order connector separately, see chapter accessories. 1) On power down the spool moves in a defined position. This cannot be guaranteed in case of single flow path on the control edge A T resp. B T with pressure drops above 12 bar or contamination in the hydraulic fluid. 2) Approx. 1 % opening, only zero lapped spools and underlap spools. ) Only for overlapped spools. 4) Not for flow code M (4 l/min). 5) Needs to be removed at tank pressure >5 bar. D1FP UK.indd RH

79 Catalogue HY11-5/UK Technical Data Direct Operated Proportional DC Valve Series D1FP General Design Direct operated proportional DC valve Actuation VCD actuator Size NG6 / CETOP / NFPA D Mounting interface DIN 244 / ISO 441 / CETOP RP121 / NFPA Mounting position unrestricted Ambient temperature [ C] MTTF D value [years] 75 Weight [kg] 5. Vibration resistance [g] 1 Sinus Hz acc. IEC Random noise Hz acc. IEC Shock acc. IEC Hydraulic Max. operating pressure [bar] Ports P, A, B 5, port T 5 for internal drain, 5 for external drain, port Y 5 1) Fluid Hydraulic oil as per DIN , other on request Fluid temperature [ C] Viscosity permitted [cst] / [mm 2 /s] recommended [cst] / [mm 2 /s]...8 Filtration ISO 446 (1999) 18/16/1 Nominal flow at p=5 bar per control edge 2) [l/min] / 6 / 12 / 16 / 25 / 4 Flow maximum [l/min] 9 (at p=5 bar over two control edges) Leakage at 1 bar [ml/min] <4 (zerolap spool); <5 (overlap spool) Static / Dynamic Step response at 1 % step ) [ms] <.5 Frequency response (±5 % signal) ) [Hz] 5 (amplitude ratio - db), 5 (phase lag -9 ) Hysteresis [%] <.5 Sensitivity [%] <. Temperature drift [%/K] <.25 Electrical characteristics Duty ratio [%] 1 Protection class IP65 in accordance with EN 6529 (with correctly mounted plug-in connector) Supply voltage/ripple [V] DC 22..., ripple <5 % eff., surge free Current consumption max. [A].5 Pre-fusing [A] 4. medium lag Input signal Voltage Impedance Current Impedance Current Impedance [V] [kohm] [ma] [Ohm] [ma] [Ohm] , ripple <.1 % eff., surge free,...+1 V P->A , ripple <.1 % eff., surge free,...+2 ma P->A , ripple <.1 % eff., surge free, ma P->A <.6 ma = disable, >.8 ma = according to NAMUR NE4 25 Differential input max. Code Code 5 Code 7 Enable signal (only code 5/7) Diagnostic signal [V] for terminal D and E against PE (terminal G) [V] for terminal 4 and 5 against PE (terminal W ) [V] for terminal D and E against PE (terminal G) [V] 5..., Ri = 9 kohm [V] / +Ub, rated max. 5 ma EMC EN , EN Electrical connection Code /7 6 + PE acc. EN Code PE acc. EN Wiring min. Code /7 Code 5 [mm²] [mm²] 7x1. (AWG 18) overall braid shield 8x1. (AWG 18) overall braid shield Wiring lenght max. [m] 5 1) For applications with p T >5 bar (max. 5 bar) the Y-port has to be connected and the plug in the Y-port has to be removed. 2) Flow rate for different p per control edge: Q x = Q Nom. p x ) Measured with load (1 bar pressure drop/two control edges). p Nom. D1FP UK.indd RH

80 Catalogue HY11-5/UK Characteristic Curves Flow curves at Dp = 5 bar per metering edge Spool type E1/E5 Direct Operated Proportional DC Valve Series D1FP Spool type B6 1%=Q Nom. A-T P-A Flow 5% P-B B-T % -1% % Command signal 1% Pressure gain Functional limits at 25 %, 5 %, 75 % and 1 % command signal Spool type E5M Frequency response ±5 % command signal ±9 % command signal All characteristic curves measured with HLP46 at 5 C. D1FP UK.indd RH

81 Catalogue HY11-5/UK Block Diagrams Direct Operated Proportional DC Valve Series D1FP Code Code PE 11 + PE Code PE + Enable D1FP UK.indd RH

82 Catalogue HY11-5/UK Dimensions Direct Operated Proportional DC Valve Series D1FP Surface finish BK75 4x M5x ISO Nm ±15 % NBR: SK-D1FP FPM: SK-D1FP-V HFC: SK-D1FP-H D1FP UK.indd RH

83 Catalogue HY11-5/UK Characteristics Direct Operated Proportional DC Valve Series DFP The direct operated control valve DFP of the nominal size NG1 (CETOP 5) shows extremly high dynamics combined with high flow. It is the preferred choice for highest accuracy in positioning of hydraulic axis and controlling of pressure and velocity. Driven by the patented VCD actuator the DFP reaches the frequency response of real servovalves. At power-down the spool moves in a defined position. All common input signals are available. Technical features Real servovalve dynamics (- db / 5 Hz at ±5 % input signal) Max. tank pressure 25 bar (with external drain port Y) Defined spool positioning at power-down - optional P-A/B-T or P-B/A-T or center position (for overlapped spools) Onboard electronics Spool / sleeve design DFP UK.indd RH

84 Catalogue HY11-5/UK Ordering Code Direct Operated Proportional DC Valve Series DFP D F P 9 Direct. control valve Size DIN NG1 CETOP 5 NFPA D5 Proportional control VCD Spool type Spool position on power down 1) Y-port (plugged) 4) Seals Command signal Accessories Spool/ sleeve design Design series (not required for ordering) Code Flow [l/min] Spool type at p 5 bar per metering edge Zerolap E5Y 1 Code Connection type 6 + PE acc. EN PE 5 acc. EN PE + Enable E5P 5 B6Y Q B = Q A /2 1 B6P Q B = Q A /2 5 Underlap approx. -.5 % Code Signal Function B +/- 1 V...+1 V -> P-A E +/- 2 ma...+2 ma -> P-A S ma ma -> P-A E55Y 1 E55P 5 E1Y E1P E2Y E2P B1Y B1P Overlap 18 % Q B = Q A / / 5 5 / 25 Code A 2) Code Seals N NBR V FPM H for HFC fluid Spool pos. at power down B2Y B2P Q B = Q A /2 1 / 5 5 / 25 B 2) C ) For regenerative and hybrid function at D1FB (NG1) please refer solutions with sandwich- and adaptor plates "A / A1-1665L / H / H1-1666L" in chapter 12. Please order connector separately, see chapter accessories. 1) On power down the spool moves in a defined position. This cannot be guaranteed in case of single flow path on the control edge A T resp. B T with pressure drops above 12 bar or contamination in the hydraulic fluid. 2) Approx. 1 % opening, only zerolapped spools and underlapped spools. ) Only for overlapped spools. 4) Needs to be removed at tank pressure >5 bar. DFP UK.indd RH

85 Catalogue HY11-5/UK Technical Data Direct Operated Proportional DC Valve Series DFP General Design Direct operated proportional DC valve Actuation VCD actuator Size NG1 / CETOP 5 / NFPA D5 Mounting interface DIN 244 / ISO 441 / CETOP RP121 / NFPA Mounting position unrestricted Ambient temperature [ C] MTTF D value [years] 75 Weight [kg] 6.5 Vibration resistance [g] 1 Sinus Hz acc. IEC Random noise Hz acc. IEC Shock acc. IEC Hydraulic Max. operating pressure [bar] Ports P, A, B 5, port T 5 for internal drain, 15 for external drain, port Y 5 1) Fluid Hydraulic oil as per DIN , other on request Fluid temperature [ C] Viscosity permitted [cst] / [mm 2 /s] recommended [cst] / [mm 2 /s]...8 Filtration ISO 446 (1999) 18/16/1 Flow nominal at p=5bar per control edge 2) [l/min] 5 / 1 Flow maximum [l/min] 15 Leakage at 1 bar [ml/min] <4 (zerolap spool); <1 (overlap spool) Static / Dynamic Step response at 1 % step ) [ms] <6 Frequency response (±5 % signal) ) [Hz] 2 (amplitude ratio - db), 2 (phase lag -9 ) Hysteresis [%] <.5 Sensitivity [%] <. Temperature drift [%/K] <.25 Electrical characteristics Duty ratio [%] 1 Protection class IP65 in accordance with EN 6529 (with correctly mounted plug-in connector) Supply voltage/ripple [V] 22..., ripple <5 % eff., surge free Current consumption max. [A].5 Pre-fusing [A] 4. medium lag Input signal Voltage Impedance Current Impedance Current Impedance [V] [kohm] [ma] [Ohm] [ma] [Ohm] , ripple <.1 % eff., surge free,...+1 V P->A , ripple <.1 % eff., surge free,...+2 ma P->A , ripple <.1 % eff., surge free, ma P->A <.6 ma = disable, >.8 ma = according to NAMUR NE4 25 Differential input max. Code Code 5 Code 7 [V] for terminal D and E against PE (terminal G) [V] for terminal 4 and 5 against PE (terminal W ) [V] for terminal D and E against PE (terminal G) Enable signal (only code 5/7) [V] 5..., Ri = 9 kohm Diagnostic signal [V] / +Ub, rated max. 5 ma EMC EN , EN Electrical connection Code /7 6 + PE acc. EN Code PE acc. EN Wiring min. Code /7 Code 5 [mm²] [mm²] 7 x 1. (AWG 18) overall braid shield 8 x 1. (AWG 18) overall braid shield Wiring lenght max. [m] 5 1) For applications with p T >5 bar (max. 25 bar) the Y-port has to be connected and the plug in the Y-port has to be removed. 2) Flow rate for different p per control edge: Q x = Q Nom. p x ) Measured with load (1 bar pressure drop/two control edges). p Nom. DFP UK.indd RH

86 Catalogue HY11-5/UK Characteristic Curves Functional limits* at 25 %, 5 %, 75 % and 1 % command signal Spool type E1/E2 Direct Operated Proportional DC Valve Series DFP Functional limits* at 25 %, 5 %, 75 % and 1 % command signal Spool type E5/E55 Flow Q [l/min] % 75% 5% 25% P T Pressure drop p P-T [bar] A B Flow curves at Dp = 5 bar per metering edge Spool type E5/E55, E1/E2 1%=Q Nom. * When exceeding the functional limits, for a period of time the valve will go into fail safe and power supply needs to be switched off/on to re-enable the valve P-B A-T E5/E55 E1/E2 P-A B-T 25 Flow Command signal [%] Pressure gain Frequency response ±5 % command signal ±9 % command signal DFP UK.indd RH

87 Catalogue HY11-5/UK Block Diagrams Direct Operated Proportional DC Valve Series DFP Code Code PE 11 + PE Code PE + Enable DFP UK.indd RH

88 Catalogue HY11-5/UK Dimensions Direct Operated Proportional DC Valve Series DFP Ø11 A Ø6.8 T A 1) X B B T Y P Surface finish BK85 4xM6x4 ISO Nm ±15 % NBR: SK-DFP FPM: SK-DFP-V HFC: SK-DFP-H 1) O-ring recess diameter on valve body. DFP UK.indd RH

89 Catalogue HY11-5/UK Characteristics Pilot Operated Proportional DC Valve Series DFP The series of pilot operated control valves DFP closes the gap between the direct operated DFP valves and the conventional pilot operated D1FP valves. Providing high flow capacity and practically no flow limits like D1FP in the envelope size of the DFP. The valve works with the hydraulic follower principle, with a moving sleeve as main spool. Technical features Pilot operated with hydraulic follower sleeve No flow limit up to 5 bar through the valve Defined spool positioning at power-down - optional P-A / B-T or P-B / A-T or center position (for overlapped spools) DFP* with hydraulic follower principle Outer (main-) spool Inner (pilot-) spool DFP UK.indd RH

90 Catalogue HY11-5/UK Ordering Code Pilot Operated Proportional DC Valve Series DFP D F P Direct. control valve Size DIN NG1 CETOP 5 NFPA D5 Proportional control VCD Spool type Spool position on power down Pilot connection Seals Commandsignal Accessories Spool/ body design Design series (not required for ordering) Code Flow [l/min] Spool type at p 5 bar per metering edge Zerolap E5U 8 Code Connection type 6 + PE acc. EN PE 5 acc. EN B6U Q B = Q A /2 8 Overlap E1U 8 Code Signal Function B +/- 1 V...+1 V -> P-A E +/- 2 ma...+2 ma -> P-A S ma ma -> P-A E2U 8 B1U Q B = Q A /2 8 B2U Q B = Q A /2 8 Code N V H Seals NBR FPM for HFC fluid Code Spool pos. at power down Code Inlet Drain 1 1) internal external 4 internal internal A 2) B 2) C ) Please order plugs separately. See chapter accessories. 1) For tank pressure >5 bar. 2) Approx. 1 % opening, only zerolapped spools. ) Only for overlapped spools. DFP UK.indd RH

91 Catalogue HY11-5/UK Technical Data Pilot Operated Proportional DC Valve Series DFP [Hz] 12 (amplitude ratio - db), 12 (phase lag -9 ) General Design Pilot operated proportional DC valve Actuation VCD actuator Size NG1 / CETOP 5 / NFPA D5 Mounting interface DIN 244 / ISO 441 / CETOP RP121 / NFPA Mounting position unrestricted Ambient temperature [ C] MTTF D value [years] 5 Weight [kg] 6.5 Vibration resistance [g] 1 Sinus Hz acc. IEC Random noise Hz acc. IEC Shock acc. IEC Hydraulic Max. operating pressure [bar] [bar] Ports P, A, B 5; Port T 5 for internal drain, 25 for external drain Port Y 5 1) Fluid Hydraulic oil as per DIN , other on request Fluid temperature [ C] Viscosity permitted [cst] / [mm 2 /s] recommended [cst] / [mm 2 /s]...8 Filtration ISO 446 (1999) 18/16/1 Flow nominal at p=5 bar per control edge 2) [l/min] 8 Flow maximum [l/min] 25 Leakage at 1 bar [ml/min] <18 (Zerolap spool); <1 (Overlap spool) Pilot supply pressure [bar] >5 higher than tank pressure (only internal pilot oil supply) Static / Dynamic Step response at 1 % step ) [ms] <7 Frequency response (±5 % signal) ) Hysteresis [%] <.5 Sensitivity [%] <. Temperature drift [%/K] <.25 Electrical characteristics Duty ratio [%] 1 Protection class IP65 in accordance with EN 6529 (with correctly mounted plug-in connector) Supply voltage/ripple [V] 22..., ripple <5 % eff., surge free Current consumption max. [A].5 Pre-fusing [A] 4. medium lag Input signal Voltage Impedance Current Impedance Current Impedance [V] [kohm] [ma] [Ohm] [ma] [Ohm] , ripple <.1 % eff., surge free,...+1 V P->A , ripple <.1 % eff., surge free,...+2 ma P->A , ripple <.1 % eff., surge free, ma P->A <.6 ma = disable, >.8 ma = according to NAMUR NE4 25 Differential input max. [V] for terminal D and E against PE (terminal G) for terminal 4 and 5 against PE (terminal W ) Enable signal (only code 5) [V] 5..., Ri = 9 kohm Diagnostic signal [V] / +Ub, rated max. 5 ma EMC EN , EN Electrical connection Code Code PE acc. EN PE acc. EN Wiring min. Code Code 5 [mm²] [mm²] 7 x 1. (AWG 18) overall braid shield 12 x 1. (AWG 18) overall braid shield Wiring lenght max. [m] 5 1) For applications with p T >5 bar (max. 25 bar) the Y-port has to be connected and the plug in the Y-port has to be removed. 2) Flow rate for different p per control edge: Q x = Q Nom. p x ) Measured with load (1 bar pressure drop/two control edges). p Nom. DFP UK.indd RH

92 Catalogue HY11-5/UK Characteristic Curves Pilot Operated Proportional DC Valve Series DFP Flow curves at Dp = 5 bar per metering edge Spool type E1/2, E5 Pressure gain Frequency response ±5 % command signal ±25 % command signal DFP UK.indd RH

93 Catalogue HY11-5/UK Dimensions Pilot Operated Proportional DC Valve Series DFP Block diagrams Code Code PE 11 + PE Dimensions Surface finish BK85 4xM6x4 ISO Nm ±15 % NBR: SK-DFP FPM: SK-DFP-V 1) O-ring recess diameter on valve body. DFP UK.indd RH

94 Catalogue HY11-5/UK Characteristics The series of pilot operated servo proportional valves D*1FP transfers the advantages of the Parker patented Voice Coil Drive (VCD ) to larger frame sizes and thus high flow rates. The high dynamics / high precision drive of the pilot valve allows the optimum control of the main spool and results in servo class performance of the complete valves. The D*1FP series is available in 5 sizes: D1FP NG1 (CETOP 5) D41FP NG16 (CETOP 7) D81FP NG25 (CETOP 8) for port diam. up to 26 mm D91FP NG25 (CETOP 8) for port diam. up to 2 mm D111FP NG2 (CETOP 1) The safety concept works with a safe 4th position at the D1FP pilot valve. This ensures that the main stage is hydraulically balanced at power down and allows to have the main spool spring centered (for overlapped spools) or approximately 1 % spring offset to spool position A or B (for zerolap spools). The innovative integrated regenerative function into the A-line (optional) allows new energy saving circuits for differential cylinders. The hybrid version can be switched between regenerative mode and standard mode at any time. Technical features High dynamics High flow Defined spool positioning at power-down - optional P-A/B-T or P-B/A-T or center position (for overlapped spools) Onboard electronics Energy saving A-regeneration Switchable hybrid version D41FPE52 (Standard) Pilot Operated Servo Proportional DC Valve Series D*1FP D41FP Standard a A B P T A-regeneration D*1FPR b G G Further literature about the opportunities of energy savings and more functional details of the integrated regeneration is available on request. a A B P T Standard D*1FPE a A B P T Hybrid D*1FPZ b b G G G G A B a b G a b G P X Y T D_1FP UK.indd RH

Chapter 3: Proportional DC Valves

Chapter 3: Proportional DC Valves Catalogue HY11-5/UK Contents Chapter : Proportional DC Valves Series Description Size DIN/ISO direct pilot Operation Electronics external onboard LVDT Spool Design Page Overlap Zero lap Spool/ Sleeve Introduction

More information

Proportional Directional Control Valves Series D*1FB. General Description. Features D91FB OBE

Proportional Directional Control Valves Series D*1FB. General Description. Features D91FB OBE Technical Information Series D*1FB General Description Series D*1FB pilot operated proportional directional valves come in 4 sizes: D31FB NG10 (CETOP 5) D41FB NG16 (CETOP 7) D91FB NG25 (CETOP 8) D111FB

More information

Proportional Pressure Reducing Valve Series D1FV

Proportional Pressure Reducing Valve Series D1FV Characteristics roportional ressure Reducing Valve Series D1FV he proportional pressure reducing valves series D1FV are available with and without onboard electronics (OE). D1FV OE he digital onboard electronics

More information

Pilot-Operated Proportional DC Valve Series D*1FH

Pilot-Operated Proportional DC Valve Series D*1FH Characteristics The pilot-operated proportional DC valves series of the D*1FH series are high-performance valves with electronic spool position feedback. These valves are available in sizes NG10 to NG2

More information

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW Characteristics The pilot operated valves are available in 4 sizes: D31DW NG10 (standard) D31NW NG10 (high flow) D41VW NG16 D81VW NG5 (for port diameter up to 6 mm) D91VW NG5 (for port diameter up to 3

More information

Proportional Directional Control Valves Series D*1FE. General Description. Features. D41FE Standard

Proportional Directional Control Valves Series D*1FE. General Description. Features. D41FE Standard Technical Information General Description pilot operated proportional valves are designed for high precision applications that require a safe middle position of the main spool at power down. The pilot

More information

Chapter 2: Directional Control Valves

Chapter 2: Directional Control Valves Contents Chapter : Directional Control Valves Series Description Direct operated Pilot operated Page DIN / ISO 06 10 16 5 3 10 16 5 3 Seat valves, electrically operated D1SE - Spool valves, electrically

More information

Directional Control Valve Series D1VW

Directional Control Valve Series D1VW Characteristics The NG6 directional control valve series D1VW provides high functional limits up to 8 l/min in combination with a very low, energy-saving pressure drop. A wide variety of spool options

More information

Proportional Pressure Relief Valves Series R4V and R6V (Onboard Electronics) General Description. Features.

Proportional Pressure Relief Valves Series R4V and R6V (Onboard Electronics) General Description. Features. Catalog HY14-2/US Technical Information General Description Series R4V and R6V proportional pressure relief valves feature onboard electronics based on the functionality of the digital amplifier PCD. The

More information

Pilot-Operated Directional Control Valves Series D3 - D11

Pilot-Operated Directional Control Valves Series D3 - D11 Catalogue HY11-500/UK Characteristics The D31, D41, D81, D91 and D111 are electrical controlled 4/3 or 4/ way directional control valves. The valves are pilot-operated by an NG6 valve. Pressure and flow

More information

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW Characteristics The D31, D41, D81, D91 and D111 are electrically controlled 4/3 or 4/ way directional control valves. The valves are pilot operated by an NG6 valve. Pressure and flow of the pilot oil have

More information

Pilot Operated Proportional DC Valve Series D*1FW / D*1FT

Pilot Operated Proportional DC Valve Series D*1FW / D*1FT Characteristics The D*1FW / D*1FT pilot-operated proportional DC valves are available in NG10 (CETOP5), NG16 (CETOP7) and NG25 (CETOP8). These valves (D*1FW) are controlled electrically with the external

More information

Explosion-Proof Valves. According to Directive 94/9/EC (ATEX) and IECEx Requirements

Explosion-Proof Valves. According to Directive 94/9/EC (ATEX) and IECEx Requirements Explosion-Proof Valves ccording to Directive 94/9/EC (EX) and IECEx Requirements WRNING USER RESPONSIILIY FILURE OR IMPROPER SELECION OR IMPROPER USE OF HE PRODUCS DESCRIED HEREIN OR RELED IEMS CN CUSE

More information

Directional Control Valve Series 4D01 (DENISON)

Directional Control Valve Series 4D01 (DENISON) Characteristics The Denison series 4D01 is a solenoid operated directional control valve size NG06 in -chamber design. It is direct operated by wet pin solenoids. The 4D01 is available with a Soft Shift

More information

Directional Control Valve Series D3W (Parker), 4D02 (Denison)

Directional Control Valve Series D3W (Parker), 4D02 (Denison) Characteristics Series D3W (Parker), 4D0 (Denison) The direct operated directional control valve size NG10 is available with both Parker (series D3W) and Denison (series 4D0) model codes. Both series are

More information

Directional Control Valve Series D3W Soft Shift

Directional Control Valve Series D3W Soft Shift Characteristics The D3W is a 3-chamber, electrically controlled 4/3 or 4/ way directional control valve. It is activated directly by solenoids with screwed in wet pin armature. The soft shifting of this

More information

Pilot Operated Directional Control Valves Series D1VP, D3DP, D4P, D9P, D11P

Pilot Operated Directional Control Valves Series D1VP, D3DP, D4P, D9P, D11P Characteristics Series D1VP, D3DP, D4P, D9P, D11P The D1VP is a hydraulically controlled 4/3 or 4/ way directional control valve. The valve can be operated either by the pilot ports X and Y via the subplate

More information

Chapter 5: Flow Valves

Chapter 5: Flow Valves Catalogue HY11-300/UK Contents Chapter : Flow Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/4 3/8 1/2 3/4 1 06 10 16 Throttle valves, manual adjustment MVI -2 NS -4 FS With free

More information

Directional Control Valve

Directional Control Valve Characteristics The NG6 directional control valve series D1VW provides high functional limits up to 8 l/min in combination with a very low, energy-saving pressure drop. wide variety of spool options allows

More information

Chapter 8: Slip-In Cartridge Valves

Chapter 8: Slip-In Cartridge Valves Contents Chapter : Slip-In Cartridge Series Description Size Page DIN / ISO 16 25 32 40 50 63 0 100125 2 way slip-in cartridge valves Introduction, hydraulic symbols, installation dimensions -2 CE / CP

More information

Proportional pressure reducing valves type DHRZO direct operated, ISO 4401 size 06

Proportional pressure reducing valves type DHRZO direct operated, ISO 4401 size 06 www.atos.com Table TF040-4/E Proportional pressure reducing valves type DHRZO direct operated, ISO 440 size 06 A DHRZO are 3 way, proportional pressure reducing valves, direct operated, with standard ISO

More information

Chapter 7: Sandwich Valves

Chapter 7: Sandwich Valves Contents Chapter : Sandwich Valves Series Description Size Page DIN / ISO 06 10 16 25 DC valve Z1DW Shut-off valve -2 Pressure relief valves, manual operation RDM RM ZDV PRDM PRM ZDR Direct operated Pilot

More information

Direct Operated Proportional DC Valves

Direct Operated Proportional DC Valves echnical Information Direct Operated roportional DC Valves Series D1F and D3F General Series D1F and D3F directional control valves of nominal sizes NG6 (CEO 3) and NG10 (CEO 5) respectively, provide variable

More information

PRM7-04. Functional Description HA /2012. Proportional Directional Control Valves. Replaces HA /2009

PRM7-04. Functional Description HA /2012. Proportional Directional Control Valves. Replaces HA /2009 Proportional Directional Control Valves PRM7-6/ Size D () bar (6 PSI) L/min (. GPM ) Replaces /9 Digital control Compact design Operated by proportional solenoids High sensitivity and slight hysteresis

More information

Proportional Pressure Relief Valve Series RE*T

Proportional Pressure Relief Valve Series RE*T Characteristics The pressure relief valve series RE*T have a proportional solenoid operated pilot stage with integrated electronics and a cartridge main stage. Features Pilot-operated pressure relief valve

More information

PRM7-06. Functional Description HA /2006. Proportional Directional Control Valves. Replaces HA /2002

PRM7-06. Functional Description HA /2006. Proportional Directional Control Valves. Replaces HA /2002 Proportional Directional Control Valves PRM7-6 HA 59 /6 Size D (6)...6 PSI ( bar)...6 GPM ( L/min) Replaces HA 57 / Digital control Compact design Operated by proportional solenoids High sensitivity and

More information

PRM7-06. Functional Description HA /2014. Proportional Directional Control Valves. Replaces HA /2013

PRM7-06. Functional Description HA /2014. Proportional Directional Control Valves. Replaces HA /2013 Proportional Directional Control Valves PRM7-6 / Size 6 (D ) bar (76 PSI) L/min (.6 GPM) Replaces HA 7 / Digital control Compact design Operated by proportional solenoids High sensitivity and slight hysteresis

More information

CONTINENTAL HYDRAULICS VED03MX

CONTINENTAL HYDRAULICS VED03MX CONTINENTAL HYDRAULICS VED03MX HIGH PERFORMANCE, SERVO-PROPORTIONAL DIRECTIONAL CONTROL VALVE 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400 / WWW.CONTINENTALHYDRAULICS.COM VED03MX HIGH

More information

4/3 directional control valve, pilot operated, with electric position feedback and integrated electronics (OBE)

4/3 directional control valve, pilot operated, with electric position feedback and integrated electronics (OBE) 4/ directional control valve, pilot operated, with electric position feedback and integrated electronics (OBE) RE 977/.1 Replaces: 1.9 1/16 Type 4WRVE 1...7, symbols V, V1 Sizes 1, 16, 5, 7 Component series

More information

Chapter 6: Check Valves

Chapter 6: Check Valves Contents Chapter : Check Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 0 10 1 25 32 Subplate Screw-in Slip-in SSR RK / RB CS SPZBE SPV / SPZ C4V CPS C4V D4S

More information

Proportional directional control valve, pilot operated with on-board electronics (OBE) and inductive position transducer

Proportional directional control valve, pilot operated with on-board electronics (OBE) and inductive position transducer Proportional directional control valve, pilot operated with on-board electronics (OBE) and inductive position transducer RE 29076/12.05 1/24 Type 4WRBKE Nominal size (NG) 10, 16, 27, 35 Unit series 1X

More information

Proportional relief valves

Proportional relief valves www.atos.com Table FS007-1/E Proportional relief valves digital, direct operated, open loop Valve body Proportional solenoid Spring Poppet Integral electronics US connector Fieldbus connector Main connector

More information

Proportional reducing valves

Proportional reducing valves www.atos.com Table FS015-0/E Proportional reducing valves digital, direct operated, open loop Valve body Proportional solenoid Spool Integral electronics Main connector Fieldbus connector US connector

More information

4/3 proportional directional control valve, without position control, with on-board electronics (OBE)

4/3 proportional directional control valve, without position control, with on-board electronics (OBE) 4/3 proportional directional control valve, without position control, with on-board electronics (OBE) Type 4WRBAE..E.. /..W.. Nominal size (NG) 6, 10 Unit series 2X Maximum working pressure P, A, B 315

More information

Pilot operated proportional directional valves

Pilot operated proportional directional valves /6 Pilot operated proportional directional valves 6. Type WRLE Sizes to 7 Up to 5 bar Up to L/min Contents Function and configuration Symbols Specifications Technical data -5 Electrical connection Technical

More information

Chapter 10: Valves for Pipe Mounting

Chapter 10: Valves for Pipe Mounting Contents Chapter : Valves for Pipe Mounting Series Description Size Body Page DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 1¼ 1½ 2 L-port T-port Pressure valves, manual operation R4V R4R Pressure relief function Pressure

More information

Proportional pressure reducing valve, pilot operated, with on-board electronics (OBE) and position feedback

Proportional pressure reducing valve, pilot operated, with on-board electronics (OBE) and position feedback Proportional pressure reducing valve, pilot operated, with on-board electronics (OBE) and position feedback Type DREBE6X Nominal size (NG) 6 Unit series 1X Maximum working pressure P 315 bar, T 250 bar

More information

Mounting Position Any Ambient Temperature Range -20 C to +60 C (-4 F to +140 F) Protection Class IP 20 acc. DIN 40050

Mounting Position Any Ambient Temperature Range -20 C to +60 C (-4 F to +140 F) Protection Class IP 20 acc. DIN 40050 rivers Series PW00-400 General escription Series PW00-400 electronic module for driving open loop proportional valves is compact and easy to install with IN rail mounting and plug-in terminals. The digital

More information

Proportional cartridge throttle valve, with on-board electronics (OBE) and inductive position transducer, pilot operated

Proportional cartridge throttle valve, with on-board electronics (OBE) and inductive position transducer, pilot operated Proportional cartridge throttle valve, with on-board electronics (OBE) and inductive position transducer, pilot operated RE 29216/09.05 1/18 Type FESE Nominal size 16, 25, 32, 40, 50 Unit series 1 Maximum

More information

Servo solenoid valves with on-board electronics (OBE)

Servo solenoid valves with on-board electronics (OBE) Servo solenoid valves with on-board electronics (OBE) RE 29045/10.05 Replaces: 01.05 1/12 Type 5WRPE 10 Size 10 Unit series 2X Maximum working pressure P 1, P 2, A, B 210 bar, T 50 bar Nominal flow rate

More information

4/3-Proportional Solenoid Valve direct acting with integrated Electronics Subplate to ISO4401 P4WEE 10

4/3-Proportional Solenoid Valve direct acting with integrated Electronics Subplate to ISO4401 P4WEE 10 4/3-Proportional Solenoid Valve direct acting with integrated Electronics Subplate to ISO4401 P4WEE 10 SYMOL E a P T b FETURES High flow rate due to optimized casted housing Low hysteresis by super finish

More information

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE) Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE) Type 4WRPE RE 29122 Edition: 2014-11 Size 10 Component series 3X Maximum operating pressure

More information

Chapter 6: Check Valves

Chapter 6: Check Valves Contents Chapter : Check Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/8 1/4 3/8 1/2 3/4 1 0 10 1 25 32 Subplate Screw-in Slip-in Shuttle valves SSR -2 Check valves, direct operated

More information

Proportional pressure relief valve, pilot operated, with on-board electronics (OBE) and position feedback

Proportional pressure relief valve, pilot operated, with on-board electronics (OBE) and position feedback Proportional pressure relief valve, pilot operated, with on-board electronics (OBE) and position feedback RE 29159/07.05 1/10 Type DBEBE6X Nominal size 6 Unit series 1X Maximum working pressure P 315 bar,

More information

Proportional Throttle Valves Series TDL

Proportional Throttle Valves Series TDL Catalogue HY11-200/UK Characteristics Function Proportional throttle valves are designed to include three stages. The main valve poppet is controlled by a hydraulic follower. The position of the hydraulic

More information

Directional Seat Valve Series D4S (Denison)

Directional Seat Valve Series D4S (Denison) Characteristics Seat valves series D4S are designed for directional control functions. A large variety of poppets, springs and covers - including shuttle valves, stroke limiters, solenoid valves (VV01)

More information

Proportional relief valves with integral pressure transducer

Proportional relief valves with integral pressure transducer www.atos.com Table FS067-/E Proportional relief valves with integral pressure transducer digital, pilot operated, closed loop high performances, rugged design Valve body Poppet Proportional solenoid Integral

More information

Directional servo-valve of 4-way design

Directional servo-valve of 4-way design Courtesy of CM/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (0) 426-54 www.cmafh.com Directional servo-valve of 4-way design Type 4WSE3E 32 Size 32 Component series 5X Maximum

More information

4/4 directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

4/4 directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE) 4/4 directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE) Type 4WRPEH RE 29121 Edition: 2014-01 Size 6 Component series 3X Maximum operating pressure

More information

Servo solenoid valves with on-board electronics (OBE)

Servo solenoid valves with on-board electronics (OBE) Servo solenoid valves with on-board electronics (OBE) RE 29077/01.05 1/16 Replaces: 01.03 Type 4WRVE10...25 Size 10, 16, 25 Unit series 2X Maximum working pressure P, A, B 350 bar, T, X, Y 250 bar Nominal

More information

4/3 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback

4/3 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback 4/3 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback RE 29025/01.05 1/16 Replaces: 05.04 Type 4WRPE..E.. /..W.. Size 6, 10 Unit series 2X Maximum working pressure

More information

VED05MJ - PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE & POSITION FEEDBACK

VED05MJ - PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE & POSITION FEEDBACK CONTINENTAL HYDRAULICS VED05MJ PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE & POSITION FEEDBACK VED05MJ - PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE & POSITION FEEDBACK 5505 WEST 123RD STREET

More information

Servo solenoid valves with on-board electronics (OBE)

Servo solenoid valves with on-board electronics (OBE) Servo solenoid valves with on-board electronics (OBE) RE 29037/10.05 Replaces: 01.05 1/12 Type 4WRPEH 10 Size 10 Unit series 2X Maximum working pressure P, A, B 315 bar, T 250 bar Nominal flow rate 50...100

More information

Proportional Pressure Reducing Valves Series PE*W (Parker), R4R (Denison)

Proportional Pressure Reducing Valves Series PE*W (Parker), R4R (Denison) Characteristics / Technical Data Series PE*W (Parker), RR (Denison) Subplate mounted proportional pressure reducing valves are available with both Parker (series PE*W) and Denison (series RR) model codes.

More information

Directional Control Valves Series D111VW. General Description. Features. Performance Curves

Directional Control Valves Series D111VW. General Description. Features. Performance Curves Technical Information General valves are piloted by a D1VW valve. The valves can be ordered with position control. The minimum pilot pressure must be ensured for all operating conditions of the directional

More information

Proportional directional valve, pilot-operated, with integrated electronics (OBE)

Proportional directional valve, pilot-operated, with integrated electronics (OBE) Proportional directional valve, pilot-operated, with integrated electronics (OBE) Type WFCE RE 943 Edition: 7- Replaces: 6- Size 6 5 Component series X Maximum operating pressure 4 bar Maximum flow 5 l/min

More information

VED05MG CONTINENTAL HYDRAULICS PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE VED05MG - PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE

VED05MG CONTINENTAL HYDRAULICS PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE VED05MG - PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE CONTINENTAL HYDRAULICS VED05MG PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400 / FAX: 952.895.6444 / WWW.CONTINENTALHYDRAULICS.COM POWERFUL

More information

4/2 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback

4/2 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service 4/2 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback RA 29024/01.05

More information

Proportional directional valve, direct operated, with pq functionality

Proportional directional valve, direct operated, with pq functionality Proportional directional valve, direct operated, with pq functionality RE 2914/3.13 Replaces: 12.12 1/18 Type STW 19, type STW 196 STW 19: Size 6 Component series 2X STW 196: Size 1 Component series 1X

More information

Publ. 3-EN 2950-A. DENISON HYDRAULICS Pressure Relief Valve R6V

Publ. 3-EN 2950-A. DENISON HYDRAULICS Pressure Relief Valve R6V Publ. 3-EN 2950-A DENISON HYDRAULICS Pressure Relief Valve R6V FEATURES, SYMBOL FEATURES High Performance: R6V valves are designed for a maximum pressure of 350 bar and a flow capacity up to 650 l/min.

More information

Proportional reducing valves

Proportional reducing valves www.atos.com Table FS070-1/E Proportional reducing valves digital, pilot operated, open loop, subplate or modular mounting Main spool Proportional pilot relief valve Pilot flow compensator Integral electronics

More information

Servo solenoid valves with positive overlap and on-board electronics

Servo solenoid valves with positive overlap and on-board electronics Servo solenoid valves with positive overlap and on-board electronics RE 29089/01.05 1/22 Replaces: 05.04 Type 4WRLE 10...35, symbols E./W. Nominal size 10, 16, 25, 35 Unit series 3X Maximum working pressure

More information

Proportional reducing valves with integral pressure transducer

Proportional reducing valves with integral pressure transducer www.atos.com Table FS020-2/E Proportional reducing valves with integral pressure transducer digital, direct operated, closed loop high performances, rugged design Valve body Poppet Proportional solenoid

More information

Servo solenoid valves with on-board electronics (OBE)

Servo solenoid valves with on-board electronics (OBE) Servo solenoid valves with on-board electronics (OBE) RE 29088/01.05 1/18 Replaces: 05.04 Type 4WRLE10...35, symbols V/V1 Size 10, 16, 25, 35 Unit series 3X Maximum working pressure P, A, B 350 bar, T,

More information

VED*MJ - PILOTED PROPORTIONAL DIRECTION CONTROL VALVES WITH OBE & FEEDBACK

VED*MJ - PILOTED PROPORTIONAL DIRECTION CONTROL VALVES WITH OBE & FEEDBACK CONTINENTAL HYDRAULICS VED*MJ PILOTED PROPORTIONAL DIRECTION CONTROL VALVES WITH OBE & FEEDBACK 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400 / WWW.CONTINENTALHYDRAULICS.COM VED*MJ PILOTED

More information

Proportional reducing valves

Proportional reducing valves www.atos.com Table FS050-1/E Proportional reducing valves digital, pilot operated, open loop Valve body Main spool Pilot flow compensator Integral pressure limiter Pilot relief valve Integral electronics

More information

Proportional directional valves type DPZO-A* two stage without position transducer, ISO 4401 sizes 10, 16 and 25

Proportional directional valves type DPZO-A* two stage without position transducer, ISO 4401 sizes 10, 16 and 25 wwwatoscom Table F70-0/E Proportional directional valves type DPZO-A* two stage without position transducer, ISO 440 sizes 0, 6 and 5 Valve body Main stage Spool Pilot valve Integral electronics MODEL

More information

Servo solenoid valves with on-board electronics (OBE)

Servo solenoid valves with on-board electronics (OBE) Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Servo solenoid valves with on-board electronics (OBE) RA 29045/01.05 1/12 Model 5WRPE 10 Size 10 Unit

More information

PRM2-06. Functional Description HA /2014. Proportional Directional Control Valves. Replaces HA /2013. Size 06 p max 350 bar Q max 40 L/min

PRM2-06. Functional Description HA /2014. Proportional Directional Control Valves. Replaces HA /2013. Size 06 p max 350 bar Q max 40 L/min Proportional Directional Control Valves Size 06 p max 50 bar Q max 40 L/min PRM-06 HA 5104 /014 Replaces HA 5104 /01 Compact design with integrated High reliability Simple replacement of the exciting coils

More information

Sentronic PLUS 614 Series

Sentronic PLUS 614 Series Sentronic PLUS 64 Series Proportional Technology www.asco.com PRESSURE CONTROL: 64 SERIES SENTRONIC PLUS Sentronic PLUS Sentronic PLUS is a digitally operated pressure regulator valve. This valve accurately

More information

Proportional directional valves type DPZO-A* two stage without position transducer, ISO 4401 sizes 10, 16 and 25

Proportional directional valves type DPZO-A* two stage without position transducer, ISO 4401 sizes 10, 16 and 25 wwwatoscom Table F70-9/E Proportional directional valves type DPZO-* two stage out position transducer, ISO 0 sizes 0, 6 and 5 Communication plastic connector, see section 5 DPZO-E-5 DPZO-ES-PS-7 (dotted

More information

VED*MJ PILOT OPERATED DIRECTIONAL CONTROL VALVES WITH OBE & FEEDBACK

VED*MJ PILOT OPERATED DIRECTIONAL CONTROL VALVES WITH OBE & FEEDBACK CONTINENTAL HYDRAULICS VED*MJ PILOT OPERATED DIRECTIONAL CONTROL VALVES WITH OBE & FEEDBACK 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400 / WWW.CONTINENTALHYDRAULICS.COM DURABLE VED*MJ

More information

Servo solenoid valves with positive overlap and on-board electronics (OBE)

Servo solenoid valves with positive overlap and on-board electronics (OBE) Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service Servo solenoid valves with positive overlap and on-board electronics (OBE) RA 2989/1.5 1/24 Model 4WRLE

More information

4/3 proportional directional valve, direct operated, with pq functionality and field bus interface (IAC-P)

4/3 proportional directional valve, direct operated, with pq functionality and field bus interface (IAC-P) 4/3 proportional directional valve, direct operated, with pq functionality and field bus interface (IAC-P) Type 4WREQ Sizes 6 and Component series 2X Maximum operating pressure 35 bar Maximum flow 8 l/min

More information

Throttle Check Valve Series FM

Throttle Check Valve Series FM Characteristics Double-throttle check valves from the Parker Manapak series FM are in sandwich design for easy configuration of stack systems. Throttle and check valves are located in ports A and B. FM2

More information

Proportional relief valves with integral pressure transducer

Proportional relief valves with integral pressure transducer www.atos.com Table FS010-/E roportional relief valves with integral pressure transducer digital, direct operated, closed loop high performances, rugged design Valve body oppet roportional solenoid Integral

More information

Proportional directional valves type DHZO-T* and DKZOR-T* direct operated, with position transducer, ISO 4401 size 06 and 10

Proportional directional valves type DHZO-T* and DKZOR-T* direct operated, with position transducer, ISO 4401 size 06 and 10 www.atos.com Table F65-/E Proportional directional valves type DHZO-T* and DKZOR-T* direct operated, with position transducer, ISO 440 size 06 and 0 Valve body Spool Proportional solenoid Position transducer

More information

D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10

D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10 D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10 OVERVIEW Section Page MOOG SERVO-PROPORTIONAL CONTROL VALVES Overview 2 3 Technical Data 4 5 Electronics

More information

20 l/min (5 GPM) p max. Technical Features

20 l/min (5 GPM) p max. Technical Features Proportional Directional Control Valve, with Analogue Control Electronics PRM2-0 Functional Description Size 0 (D02) Q max 20 l/min (5 GPM) p max 320 bar (600 PSI) Technical Features Direct acting, proportional

More information

Proportional directional valves type DHZO-AES and DKZOR-AES direct operated, without position transducer, ISO 4401 size 06 and 10

Proportional directional valves type DHZO-AES and DKZOR-AES direct operated, without position transducer, ISO 4401 size 06 and 10 www.atos.com Table F60-8/E Proportional directional valves type DHZO-AES and DKZOR-AES direct operated, without position transducer, ISO 440 size 06 and 0 AES execution included in this table is available

More information

DSE3B /118 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 10 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min

DSE3B /118 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 10 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min 83 215/118 ED DSE3B DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SUBPLATE MOUNTING ISO 4401-03 p max 350 bar Q max 40 l/min MOUNTING INTERFACE OPERATING PRINCIPLE ISO 4401-03-02-0-05 (CETOP 4.2-4-03-350)

More information

Operation Manual Series TDP/TEP. 2-Way High-Response Valves. Design > 40. Bulletin HY /UK

Operation Manual Series TDP/TEP. 2-Way High-Response Valves. Design > 40. Bulletin HY /UK Bulletin HY11-5715-697/UK Operation Manual Design > 40 2-Way High-Response Valves Parker Hannifin Manufacturing Germany GmbH & Co. KG Hydraulic Controls Division Europe Gutenbergstr. 38 41564 Kaarst, Germany

More information

DXPE*J /117 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 31

DXPE*J /117 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 31 85 320/117 ED DXPE*J DIRECtIONL CONtROL VLVE PILOt OPERtED, WItH OE ND FEEDCK SUPLtE MOUNtINg DXPE5J CEtOP P05 DXPE5RJ ISO 4401-05 DXPE7J ISO 4401-07 DXPE8J ISO 4401-08 p max (see performance table) Q

More information

NG6. Proportional adjustment. Manifold mounting acc. to ISO External drain. Main stage spool type valve. Pilot stage seated type valve.

NG6. Proportional adjustment. Manifold mounting acc. to ISO External drain. Main stage spool type valve. Pilot stage seated type valve. Catalog HY14-255/US Technical Information Series VY*K General Description Series VY*K pilot operated sequence valves feature proportional adjustment and an external drain. The external drain allows application

More information

Proportional cartridge throttle valve, with inductive position transducer, pilot operated

Proportional cartridge throttle valve, with inductive position transducer, pilot operated Proportional cartridge throttle valve, with inductive position transducer, pilot operated RE 29215/09.05 1/18 Type FESX Nominal size 16, 25, 32, 40, 50 Unit series 1X Maximum working pressure A, B, X 315

More information

4-way directional servo valve Type 4WS.2E

4-way directional servo valve Type 4WS.2E RE 29 91/06.02 Replaces: 03.93 4-way directional servo valve Type 4WS.2E Nominal size 16 Series 2X Maximum operating pressure 2/31 bar Maximum flow 3 L/min Overview of contents Contents Page Features 1

More information

ZRV. Direct Operated Check Valve Series ZRV (Denison)

ZRV. Direct Operated Check Valve Series ZRV (Denison) Characteristics / Ordering Code Direct Operated Check Valve Series ZRV (Denison) Direct operated check valves series ZRV have a cartridge type insert to provide zero leakage and high life time. he check

More information

Hydraulic Valves «DSV»

Hydraulic Valves «DSV» Hydraulic Valves «DSV» Edition 09 01 Hydraulic Valves «DSV» Table of contents General information Integrated electronics amplifier and controller «DSV»...1.13-75 Product over-view and/or data sheets Proportional

More information

Industrial Hydraulics FAQs

Industrial Hydraulics FAQs Industrial Hydraulics FAQs FAQ Title: H in 4WRPEH model code Category: Proportional and Servo Valves Sub-Category: Directional Control Valves Bosch Rexroth Corporation Hydraulics 2315 City Line Road Bethlehem,

More information

Chapter 5: Flow Valves

Chapter 5: Flow Valves Contents Chapter 5: Flow Valves Series Description Size Mounting Page Parker Standard DIN / ISO 1/4 3/8 1/2 3/4 1 0 10 1 Subplate Screw-in Throttle valves, manual adjustment MVI 5-3 NS 5-5 FS With free

More information

4/3-way servo solenoid directional control valves, pilot operated, with electrical position feedback (Lvdt DC/DC ±10V)

4/3-way servo solenoid directional control valves, pilot operated, with electrical position feedback (Lvdt DC/DC ±10V) 1/16 4/3-way servo solenoid directional control valves, pilot operated, with electrical position feedback (Lvdt DC/DC ±1V) RE 2986/1.9 Replaces: 1.5 Type 4WRL 1...35, symbols V/V1 Sizes (N) 1, 16, 25,

More information

40 l/min (11 GPM) p max

40 l/min (11 GPM) p max Proportional Directional Control Valve, with Analog Control Electronics PRM2-06 Functional Description Size 06 (D03) Q max 40 l/min (11 GPM) p max 350 bar (5100 PSI) Technical Features Direct acting, proportional

More information

Servo solenoid valves with positive overlap Position feedback (Lvdt DC/DC ±10 V)

Servo solenoid valves with positive overlap Position feedback (Lvdt DC/DC ±10 V) Servo solenoid valves with positive overlap Position feedback (Lvdt DC/DC ±10 V) RE 29087/01.05 1/22 Replaces: 05.04 Type 4WRL 10 35, symbols E. / W. Nominal size 10, 16, 25, 35 Unit series 3X Maximum

More information

2-way proportional throttle valve for block installation

2-way proportional throttle valve for block installation -way proportional throttle valve for block installation RE 90/07.05 Replaces: 03.00 / Types FE; FEE Size 6 Component series X Maximum operating pressure 35 bar Maximum flow 90 L/min bei p = 0 bar H4538

More information

Proportional relief valves with integral pressure transducer

Proportional relief valves with integral pressure transducer www.atos.com Table FS040-/E Proportional relief valves with integral pressure transducer digital, pilot operated, closed loop high performances, rugged design Valve main body Main poppet Mechanical pressure

More information

Remote Process Actuation Control System AirLINE WAGO Remote I/Os and Fieldbusses

Remote Process Actuation Control System AirLINE WAGO Remote I/Os and Fieldbusses Remote Process Actuation Control System AirLINE WAGO Remote I/Os and Fieldbusses Type 8644 can be combined with... Fully compatible with WAGO I/O Combination of Fieldbus, pilot valves and I/O modules High

More information

Sentronic D 608 Series and 609 Series

Sentronic D 608 Series and 609 Series Sentronic D 608 Series and 609 Series Proportional Technology www.asco.com PRESSURE CONTROL: 608/609 SERIES SENTRONIC D Sentronic D Sentronic D is a digitally operated pressure regulator valve. Sentronic

More information

VED*MG - PILOT OPERATED PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE

VED*MG - PILOT OPERATED PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE CONTINENTAL HYDRAULICS VED*MG PILOT OPERATED PROPORTIONAL DIRECTIONAL CONTROL VALVES WITH OBE 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400 / WWW.CONTINENTALHYDRAULICS.COM VED*MG PILOT

More information

4/2 servo solenoid valves with positive overlap and position feedback (Lvdt AC/AC)

4/2 servo solenoid valves with positive overlap and position feedback (Lvdt AC/AC) Electric Drives and Controls Hydraulics Linear Motion and Assembly Technologies Pneumatics Service 4/2 servo solenoid valves with positive overlap and position feedback (Lvdt AC/AC) Model 4WRP..E.. /..W..

More information

3-way servo solenoid valves, cartridge type, pilot operated, with inductive position transducer

3-way servo solenoid valves, cartridge type, pilot operated, with inductive position transducer 3-way servo solenoid valves, cartridge type, pilot operated, with inductive position transducer Type 3WRCB 25...50 Nominal size (NG) 25, 32, 50 Unit series 1X Maximum working pressure P, A, T, X, Z 315

More information