Earth Leakage Circuit Breakers Accessories

Size: px
Start display at page:

Download "Earth Leakage Circuit Breakers Accessories"

Transcription

1 OFF OFF Earth Leakage Circuit s Accessories Variation of external accessory Insulation barriers The interphase barrier reinforces the insulation between terminals, while the earth barrier increases the insulation between the terminal and the mounting panel. See page /106 Mechanical interlock device The mechanical interlock device can be mounted onto two separate breakers to maintain a mutual ON or OFF condition. The device can also be locked with a padlock. See page /88 Interface barrier Earth barrier External operating handles There are two handles available in the series: the V type handle on panel mount and the N type handle on breaker mount. An extension shaft (sold separately) for the V type handle allows the distance between the handle and the breaker to be adjusted. The protective structure of the V type handle operation section conforms to IP54. oth handle types can be locked with a padlock conforming to IEC The panel cutout dimensions are the same for both handles. See page /91 TRIP OPEN/RESET TRIP ON N type ON ON andle locking cover OFF OPEN/RESET V type Motor-operating mechanism ELC A new drive structure in the motor operating mechanism speeds up drive operation to drastically reduce ON/OFF switching time from 2s to 0.1s. See page /85 Terminal covers Finger protection guards against shock from accidentally touching live terminals. Two types of terminal covers are availablelong type and short type. See page / Steel enclosures Enclosures are available in three typestwo with V-type handle which allows the operation from the outside, and other direct operating. See page /103 Long type Short type Information subject to change without notice /69

2 Motor-operated breakers Motor-operated breakers Description The breaker is fitted with a motor operating mechanism which enables ON, OFF and RESET operations to be carried out electronically by remote control. 4-pole motor operated breakers are also available. AF02-54 to 2AF CP-1214 AF AF and larger, 4-pole Types and ratings Motor rating Operating voltage Operating time Time rating Power source capacity SG33C/M SG53C/M, 53RC/M SG63C/M, 63RC/M EG33AC/M, 33C/M EG53AC/M, 53C/M EG63C/M EG102C/M, 103AC/M, 103C/M V DC /110V AC 200/220V AC 0.1s 15s per on-off operation 500VA SG103C/M SG103RC/M SG203C/M SG203RC/M EG203C/M 24V DC 48V DC V DC /110V AC 200/220V AC 2s 2.5s 30s 30s 50VA 50VA SG403C/M SG403RC/M SG603RC/M SG3RC/M EG403C/M EG603C/M EG3C/M /110V DC /110V AC 200/220V AC 2s 30s VA at /110V DC, /110V AC 200VA at 200/220V AC Ordering information Specify the following: 1. Type number 2. Motor operating voltage Dimensions, mm / Front mounting, front connection SG33C/M, SG53C/M, SG53RC/M, SG63C/M, SG63RC/M EG33AC/M, EG33C/M, EG53AC/M, EG53C/M, EG63C/M, EG102C/M, EG103C/M Wiring diagrams /110V AC, 200/220V AC, V DC 50 Mounting hole ø4.5 LC Insulation barrier (Except EG33AC/M, 53AC/M, SG33C/M) Operating handle M4 or ø5 Panel drilling DRIVE UNIT CONTROL CIRCUIT L C E 2 1 OFF ON Test button Terminal cover 4 Trip button Notes: Trip button operation can be carried out at right side of the breaker. IEC 35mm rail is not available. Power supply (Non polarity) Information subject to change without notice /85

3 Motor-operated breakers Dimensions, mm / Front mounting, front connection SG103RC/M, SG103C/M Wiring diagrams 24V DC, 48V DC, V DC Insuration barrier Detachable 50 R65 57 Panel drilling 2-M4 or ø Test lead wire Max /110V AC, 200/220V AC SG203C/M, SG203RC/M EG203C/M Insuration barrier Detachable Panel drilling R M4 or ø Test lead wire 142 Note: Interphase insulation barriers are standard provided for the front mounting type breakers of 50AF to 2AF Max C : Control relay for breaker closing T : Control relay for breaker open M : Motor Ca1-Cc : Relay terminal number for closing Ta1-Tc : Relay terminal number for open : Diode Z : Z-trap (Surge absorber) SS : ON/OFF changeover switch E, 1-5 : Terminal number for external wire connection : Resistor : LED : Silicon diode : Transformer : Capacitor AURS : Automatic reset switch (supplied on request) /86 Information subject to change without notice

4 Motor-operated breakers Dimensions, mm/front mounting, front connection Wiring diagrams/400 to 0AF SG403C/M, SG403RC/M EG403C/M Panel Panel drilling /110V AC, 200/220V AC, 50/60z Manual/ motor operation indicator olt M12 x 35 Test lead wire M M8 or ø7 /110V DC SG603RC/M, SG3RC/M EG603C/M, EG3C/M C A Panel Panel drilling Manual/ motor operation indicator olt M12 x 40 Test lead wire C 18 M ø7 C : Control relay for breaker closing R : Resistor T : Control relay for breaker open LS : Limit switch M : Motor AURS: Automatic reset switch (supplied on request) Amp. frame A (line side) (load side) C 600AF AF Dimensions for reference only. Confirm before construction begins. Type (ELC with motor operating mechanism) SG33C/M, SG53C/M, SG53RC/M EG33AC/M, EG33C/M, EG53AC/M, EG53C/M SG63C/M, SG63RC/M EG63C/M, EG102C/M, EG103AC/M, EG103C/M SG103C/M SG103RC/M SG203C/M, SG203RC/M EG203C/M SG403C/M, SG403RC/M, EG403C/M SG603RC/M, EG603C/M SG3RC/M, EG3C/M (kg) Information subject to change without notice /87

5 Mechanical interlocking device Mechanical interlocking devices Description These interlocking devices are mounted on the two separate breakers to prevent them from both being closed at the same time. They employ a slide method and are operated manually. These interlocking devices is possible to lock with a padlock (not supplied). They are designed for use when changing over power supplies. These can be mounted to 3 types of breakers: front-mounting frontconnection type, front-mounting rearconnection type (type X), and plug-in mounting type (type P). Interlock devices for flush mounting type breakers (type E, Y) are also available. M1 types Types and applicable breakers Type Z6M110C2 Z6M110C3 Z-M160C type SG33C SG53C, SG53RC SG63C, SG63RC SG403C, SG403RC EG32AC EG52AC EG33AC, EG33C EG53AC, EG53C EG63C EG102C EG103AC, EG103C EG403C Z-M170C SG603RC SG3RC EG603C EG3C /88 Information subject to change without notice

6 Mechanical interlocking device Dimensions, mm 30AF to EGAF C A Z6M110C2 Panel drilling 85 of slider mounting hole of breaker of breaker Padlock (Not supplied) 2-ø4.5 mounting hole 2-ø4.5 or M Z6M110C3 110 mounting hole of breaker 9 2-ø4.5 or M4 Type type Dimensions, mm A C (kg) Z6M110C2 EG32AC EG52AC Z6M110C3 SG33C SG53C SG63C SG53RC SG63RC EG33AC EG33C EG53AC EG53C EG63C EG102C EG103AC EG103C Notes: Z6M110C2 is not available for padlock. Applicable padlock(ø3.5) dimensions, mm ø3.5 ø Information subject to change without notice /89

7 Mechanical interlocking device Dimensions, mm of handle Panel drilling A' A C of slider F E of slider 10-M4 or ø5 Z6M140C J J N N Z-M160C, M170C J of handle J D G K P of breaker L of breaker Q Padlock (not supplied) Mounting screw (Provided) J' J' J' J' M6 or ø7 (Z-M140C: 8-M4 or ø5) Type type Dimensions, mm A (A') C D E F G J (J') K L (kg) Z-M160C SG403C SG403RC EG403C 355 (70) (70) Z-M170C SG603RC SG3RC EG603C EG3C 500 () () Note: Applicable padlock(ø3.5) dimensions, mm ø3.5 ø /90 Information subject to change without notice

8 Operating handles External operating handles Description Earth leakage circuit breaker handles are generally directly manual-operated but when mounted in motor control centers or on control panels they are sometimes required to be operated externally. To meet such applications FUJI offers the following three types of handles. N type handle This type has a knob handle directly attached to the breaker. It is easily fitted by cutting a hole in the panel, which is provided with a door interlock. They may be fitted to all breakers up to 0 ampere frame sizes. N type handles for SG/EG30AF to EGAF are UL508 listed. V type handle The V type handle may be fitted to breakers of up to 0AF. A separately sold extension shaft (Z-VS1)provides distance adjustment between the handle and breaker. Conformed to EN isolation function. Available for EN power breaking device. G type handle The G type handle is mounted on the panel, and also has a door-interlock. G type handle with a cylinder lock key is also available on request. G type handle with a padlockable handle lock plate is standard provided for circuit breaker of up to 2AF, and is optional for 400AF and larger. KK AF KK Z6N10C Z-N C Z6V10C Z-G10 N type handles V type handle G type handle N type handles Z-N N type handle on breaker V type handles Z6V C Decorative plate C V type handle on panel AF G type handles Z-G10 G type handle on panel Information subject to change without notice /91

9 Operating handles For breakers up to 0AF N type handles V type handles SG33C SG53C SG53RC SG63C SG63RC SG103C SG103RC SG203C SG203RC SG403C SG403RC SG603RC SG3RC EG32AC, 33AC, 33C EG52AC, 53AC, 53C EG63C EG103AC, 102C, 103C EG203C EG403C EG603C EG3C N type handle Z6N10C UL508 (File No. E216772) Z-N30C Z-N40C Z-N60C Z-N70C SG33C SG53C SG53RC SG63C SG63RC SG53RCUL SG103C SG103CUL SG103RC SG203C SG203CUL SG203RC V type handle EG32AC, 33AC, 33C Z6V10C EG52AC, 53AC, 53C UL489 EG63C (File No. E93289) EG103AC, 102C, 103C EG102CUL, 103CUL EG203C Z6V30C UL489 (File No. E93289) Z6V40C UL489 (File No. E93289) SG53RCUL SG103CUL SG203CUL SG403CUL EG102CUL, 103CUL N type handle UL489 (File No. E93289) Z6N10CP Z6N30CP Z6N40CP Z6N60CP SG403C SG403CUL SG403RC SG603RC SG3RC EG403C EG603C EG3C Z6V60C UL489 (File No. E93289) Z6V70C UL489 (File No. E93289) Notes: N type handles for up to 0AF can be padloked. Padlock is not provided. N type handles are not CE marked. For breakers other than N type handles series V type handles SGa104A, 104 SGa204A, 204 SGa404A EG104A G series G53 G103 G203 G403 G603 G3 N type handle Z-N35 Z-N50C Z-N60C Z-N70C N-13EA N-23EA N-6EA G series G203 G403 G603, G3 V type handle Z-V50C Z-V60C Z-V70C G type handles Type G53, 103 SGa104A, 104 SGa204A, 204 SGa404A EG104A Standard Z-G35C G-12A G-22A G-5A Cylinder key type Z-G35C-K G-12A-K G-22A-K G-5A-K /92 Information subject to change without notice

10 N type operating handles N type operating handles Operating instructions 1. ELC operation Close the door with the handle in the OFF position. Turn the handle to the ON position and the ELC will be ON. Turn the handle to the OFF position and ELC will be OFF. When the breaker trips, the handle moves to the TRIP position. To reset, move the handle to the RESET position. Fig. 1 Mounting screw For N10C, N30C ase plate 2. Door locking The door cannot be opened when the handle is in the ON, OFF or TRIP position, and can be opened only when the handle is in the OPEN position. The breaker cannot be ON when the door is open. If it is necessary to open the door with the breaker closed, turn the doorclose lock release screw counterclockwise using a screwdriver. 3. andle locking The handle can be locked in either the ON or OFF position when a padlock (not supplied) is used. Pull out the handle lock plate and fit your padlock to the plate. If the breaker trips while it is locked in the ON position, the handle moves to the TRIP position. For N40C Fig. 2 For N10C, N30C Installation Z6N10C to Z-N40C 1. Drilling and cutting the door Drill and cut the door. The dimensions for drilling and cutting are the same whether the ELC is installed horizontally or vertically. Decorative plate Retaining plate 2. Preparing a base plate (Fig. 1) Prepare a base plate to adjust breaker mounting position (base plate: not supplied). Front mounting, front connection type breakers can only be suitable for this handle. Drill the breaker mounting holes on the base plate. Fig. 3 Not correct 3. Fitting the N-handle mechanism and ELC to the base plate (Fig. 1) Commonly tighten the N-handle body and ELC to the base plate with the mounting screws. For N10C to N30C, tighten two mounting screws on a diagonal line, and for N40C, tighten four mounting screws. Assemble the driving unit so that the breaker handle engages the N handle arm. (Fig. 4) ELC ELC 4. Mounting the decorative plate Mount the decorative plate and the retaining plate to the door with screws provided. (Fig. 2) Adjust the position of the handle unit so that it does not tilt against the breaker. (Fig. 3) Space Fig. 4 andle window Decorative plate Decorative plate ELC handle N handle arm Information subject to change without notice /93

11 N type operating handles Installation Z-N60C, Z-N70C 1. Drilling and cutting the door Drill and cut the door. The dimensions for drilling and cutting are the same whether the ELC is installed horizontally or vertically. Fig Preparing a base plate (Fig. 1) Prepare a base plate to adjust breaker mounting position (base plate: not supplied). Front mounting, front connection type breakers can only be suitable for this handle. Drill the breaker mounting holes on the base plate. 3. Fitting the N-handle mechanism and ELC to the base plate (Fig. 1) Commonly tighten the N-handle body and ELC to the base plate with the four mounting screws. Assemble the driving unit so that the breaker handle engages the N handle arm. (Fig. 4) 4. Mounting the decorative plate Mount the decorative plate and the retaining plate to the door with screws provided. (Fig. 2) Adjust the position of the handle unit so that it does not tilt against the breaker. (Fig. 3) Fig. 2 Fig. 3 Fig. 4 ELC andle window Not correct Decorative plate N handle arm Decorative plate Space ELC ELC handle Type number nomenclature Z N C T R Installation lank: Vertically R: orizontally, right line side L: orizontally, left line side Door locking device lank: Provided T: Not provided asic type Z6N10C Z-N C N- EA Note: To order an N handle for front-mounting rear connection breakers, add -X to the type number, for plug-in mounting breakers, add -P to the type number. /94 Information subject to change without notice

12 N type operating handles Dimensions, mm Z6N10C to Z-N50C (Dust proof paking: Z-NP-1C, optional) Line Load 69 max. Z6N10CP, Z6N30CP, Z6N40CP (Dust proof paking: Z-NP-1C, optional) Line 69Max ± Door panel cutting Door hinge installation area OFF TRIP ON FA,EL handle C/L 4-ø15 FA,EL handle C/L andle C/L ø Padlock ø4 to ø / Panel Panel thickness 1.2 to Load type SG30C, SG50C, 50RC, SG60C, 60RC SG50RCUL EG30AC, 30C, EG50AC, 50C, EG60C EGAC, C, CUL SGC, RC, CUL andle type Z6N10C Z6N10CP Z-N30C Z6N30CP A Mounting screw M4 M4 85 (kg) type EG2C SG2C, 2RC, 2CUL G2 andle type Z-N40C Z-N40CP Z-N50C A Mounting screw M4 85 M4 1 (kg) Information subject to change without notice /95

13 OPEN Earth Leakage Circuit s N type operating handles Z-N60C, Z-N70C, Z-N60CP, Z-N70CP (Dust proof packing: Z-NP-2, optional) 150 Line Mounting screw Door panel cutting 96 I T R P O N Decorative plate Lock plate 4 -ø15 andle C/L 150 RESET O F F RELEASE and handle C/L and handle C/L ø type andle Mounting type screw (kg) SG400C, SG400RC Z-N60C M6 x SG400CUL Z-N60CP EG400C G400 SG600RC, SG0RC Z-N70C M6 x EG600C, EG0C Z-N70CP G600, G0 Dimensions, mm Z-N35 (Dust proof packing: Z-NP-1, optional) Door panel cutting Line 60 max Decorative plate Panel Panel thickness 1.2 to 3.2 Mounting screw 4 -ø15 of handle Load Lock lever 43 1 ±2 Packing(Optional) 78 ø90 of panel cutting Aux. handle (Only Z-N70C) Load Door hinge installation area P Panel thickness 1.6 to 3.2 Note: andle protection degree IP50 (IEC60529, JIS C 0920) (with the optional dust-proof packing) The handle cannot hold the door. Notes: 1. The N type handles are used with front mounting front connection type breakers. They are normally installed vertically. owever, it is possible to install them horizontally if required. In this case please specify so in your order. (Example) Specify as follows: Z-N C-R... Installed horizontally, the line positioned on the right side. Z-N C-L...Installed horizontally, the line positioned on the left side. 2. s use different size screws for the P-type (Plug-in) breakers Install the door hinge in the shaded area Install the door hinge in the shaded area. 30 : 0.45kg Dimensions for refernce only. Confirm before construction begins. Dimensions of N type handles for 4-pole: Contact FUJI. /96 Information subject to change without notice

14 V type operating handles V type operating handles, up to 2AF Operating instructions 1. ELC operation Close the door and turn the handle to the ON position and the breaker will be positioned at ON. When the breaker is interrupted automatically the handle will move to the TRIP position. To reset move the handle to the RESET position. 2. Door panel locking Turn the handle to the RESET position and the lock mechanism will be released thus allowing the door to be opened. The door cannot be opened when the breaker is positioned at ON. Fig. 1 Terminal cover Fig. 3 Padlock (Not supplied) Fig. 2 Fig. 4 Lock plate 3. andle locking The padlock can lock the handle in the OFF position. Locking ELC with the door open : Fig.1 Locking ELC with the door closed : Fig.2 Pull out the lock plate and lock the padlock. 4. Interlock release This type is provided with an interlock release screw. Turn this screw if it is necessary to open the door in the ON position. This release the lock and allows the door to be opened. When reclosing the door, make sure the handle of the breaker coincides with the position (ON or OFF) of the external handle position. Fig. 5 Installation Z6V10C to V50C 1. Drilling and cutting of the door panel Drill and cut the door panel as shown in the drawing. 2. Mounting of the ELC The distance between the backside of the door panel and breaker mounting plate should be the dimension "" shown in the drawing below. dimensions, mm (Fig.3) Z6V10C: Z6V30C: Z6V40C: Z-V50C: 144 For V10C, V30C For V40C Fig. 6 Latch Mounting screw Driving unit 3. Mounting the driving unit Set the breaker handle to the OFF position. Assemble the driving unit so that the breaker handle engages the V handle arm. (Fig.4 ) Secure the driving unit and breaker together to the mounting plate by tightening the four attached mounting screws. (Fig.5) 4. Mounting the handle unit Put the handle unit, cover holder, packing, and retainer in front of and behind the panel and tighten the screws temporarily as shown in Fig.6. Adjust the position of the handle unit so that it does not tilt against the breaker. (Fig.7) Put the handle of the handle unit in the OFF position and close the door. Check that the shaft engages the latch when the door closes. (Fig.8) Fig. 7 Retainer Door panel Packing Cover holder andle unit Interlock-release screw Fig. 8 Latch Shaft Information subject to change without notice /97

15 V type operating handles Dimensions, mm Z6V10C, 6V30C, 6V40C Door panel Door panel cutting 4-ø15 andle andle andle ø Panel thickness Z-V40V, V50C Door panel Optional shaft Z-VS1 X = - 96 Door hinge installation area OP O FT R O R E andle X Panel thickness The distance between the handle and breaker can be shortened by cutting the optional shaft. 120 Install the door hinge in the shaded area. type G series andle type Standard type With the optional shaft (X=154) Area in which the hinge with can be installed Mounting screw (kg) SG30C SG50C SG50RC SG60C SG60RC SG50RCUL EG30AC EG30C EG50AC EG50C EG60C EGAC EGC EGCUL Z6V10C to 0 60 M4 x 0.64 SGC SGRC SGCUL Z6V30C to 0 60 M4 x SG2C SG2RC SG2CUL EG2C Z6V40C to 0 60 M4 x G2 Z-V50C to M4 x Notes: andle protection degree IP54 (IEC60529, JIS C 0920) The handle cannot hold the door. /98 Information subject to change without notice

16 V type operating handles V type operating handles, 400AF to 0AF Operating instructions 1. ELC operation Close the door and turn the handle to the ON position and the ELC will be positioned at ON. When the ELC is interrupted automatically the handle will move to the TRIP position. To reset move the handle to the RESET position. 2. Door panel locking Turn the handle to the RESET position and the lock mechanism will be released thus allowing the door to be opened. The door cannot be opened when the breaker is positioned at ON. 3. andle locking The padlock can lock the handle in the OFF position. Locking ELC with the door open: Fig. 1 Locking ELC with the door closed: FIg Interlock release This type is provided with an interlock release screw. Turn this screw if it is necessary to open the door at the ON position. This releases the lock and allows the door to be opened. When reclosing the door, make sure the handle of the breaker coincides with the position (ON or OFF) of the external handle position. Installation Z6V60C, 70C 1. Drilling and cutting of the door panel Drill and cut the door panel as shown in the drawing. 2. Mounting of the ELC The distance between the backside of the door panel and ELC mounting plate should be the dimension as shown in Fig Mounting the driving unit Set the ELC handle to the OFF position. Assemble the driving unit so that the ELC handle engages the V handle arm. (Fig. 4) Secure the driving unit and ELC together to the mounting plate by tightening the four attached mounting screws. (Fig. 5) 4. Mounting the handle unit Put the handle unit, packing and retainer in front of and behind the door panel and tighten the screws temporarily as shown in Fig.6. Adjust the position of the handle unit so that it does not tilt against the ELC. (Fig. 7) Put the handle of the handle unit at OFF position and check the latch engages the keeper and close the door while holding the handle unit cover by hand. Final tightening the screws should be performed as keep the engaging position. (Fig. 8) Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 Fig. 7 Type number nomenclature Fig. 8 Z6V C Mounting lank:front mounting, front connection X: Front mounting, rear connection P: Plug-in mounting asic type Z6V C Z-V C Note: To order a V handle for front-mounting rear connection breakers, add -X to the type number; for plug-in mounting breakers, add -P to the type number. Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice /99

17 V type operating handles Dimnsions, mm Z6V60C, 6V70C, Z-V60C, V70C 150 Line Door panel cutting Optional shaft ( Z-VS2) Decorative plate Panel 4-ø10 andle O F F RESET OPEN I T R P O N RELEASE 150 and handle ø x Load 150 Lock plate 63 Mounting screw 112 The distance between the handle and breaker can be shortened by cutting the optional shaft. ( X = ) Door hinge installation area Panel thickness 1.6 to Install the door hinge in the shaded area. 200 G series andle type Standard type With the optional shaft Area in which the hinge with can be installed (kg) SG400C SG400RC SG400CUL EG400C Z6V60C 190±2 0±2 202 to G400 Z-V60C 2.2 SG600RC SG0RC EG600C EG0C Z6V70C 2.2 G600 G0 Z-V70C 2.2 Notes: andle protection degree IP54 (IEC60529, JIS C0920). The handle cannot hold the door. s use different size screws for the X type (rear connection) or P-type (Pulg-in) breakers. / Information subject to change without notice

18 G type operating handles G type operating handles Operating instructions 1. ELC operation Close the door and turn the handle to the ON position and the breaker will be positioned at ON. When the breaker is interrupted automatically the handle will move to the TRIP position. To reset move the handle to the RESET position. Installation ZG35C 1. Drilling and cutting of the door panel Drill and cut the door panel as shown in the drawing. 2. Mounting of the ELC The distance between the backside of the door panel and breaker mounting plate should be 1mm as shown in the drawing below. 2. Door panel locking Turn the handle to the OPEN position and the lock mechanism will be released thus allowing the door to be opened. The door cannot be opened when the breaker is positioned at ON. Panel Thickness 1.2 to 3.2 Mounting plate 3. andle locking The cylinder key can lock the handle in either the ON or OFF position. Even if it is locked at the ON position when the breaker trips, the handle will indicate TRIP. O C K O C K 44 1 ±2 Mount the breaker and the retaining plate commonly to the panel board. L L Retaining plate Locked Unlocked 4. Interlock release This type is provided with an interlock release screw. Turn this screw if it is necessary to open the door at the ON position. This releases the lock and allows the door to be opened. When reclosing the door make sure the handle of the breaker coincides with the position (ON or OFF) of that of the external handle. Adjusting screw 3. Fitting decoratire plate and handle Fit the decorative plate and handle mechanism to the door panel by means of the mounting screws as shown in the illustration. Type number nomenclature ZG CK Key lank: Without key K: With cylinder key Q: With padlocking device asic type Z-G C G- A Mounting screw Decorative legend plate OFF TRIP ON andle Door panel Lock lever andle mechanism 4. Adjusting the retaining plate Adjust the height of the retaining plate by means of adjusting screws. Fuji Electric FA components & Systems Co., Ltd./D & C Catalog Information subject to change without notice /101

19 G type operating handles Dimensions, mm Z-G35C, Z-G35C-K : 1.2kg G-22A, G-22A-K Retaining plate and supporter (Sold separately) 36±1 Line side of breaker Load side 73 Interlock release screw OPEN 2.3 max3.2.7±0.5 Retaining plate ON or OFF Door C± OPEN 150± ±1 49 ON OFF Door panel cutting 3-ø ø29 ø mounting hole 4-ø to 141 Adjustable height 3.2 of handle /102 Information subject to change without notice

20 Steel enclosures Pressed steel enclosures Description Z-type enclosures are available in three types two with V and G-type handle which allows the operation from the outside and other with the operating handle of the breaker extending from it to allow it to be directly switched ON or OFF from outside the enclosure. Enclosures with V and G-type handles are provided with a door interlocking mechanism which prevents the door from being opened in the ON condition. Knockout holes for wiring use are provided as shown in the diagram. (For G-type handles, contact FUJI.) AF90-7 AF CP Standard Dustproof Rainproof Type of enclosures type Enclosure G series Standard With V type handle Dustproof IP40 Rainproof IP54 * EG32AC EG52AC Z6C10C2 Z6CV10C Z6CW10C SG33C SG53C, SG53RC SG63C, SG63RC EG33AC, EG33C EG53AC, EG53C EG63C Z6C10C3 Z6CV10C Z6CW10C EG102C EG103C, EG103AC Z6CC3 Z6CVC Z6CWC SG103C, SG103RC Z6C30C3 Z-CV30C Z-CW30C SG203C, SG203RC EG203C G53 G103 Z-C35 Z-C40 Z-CV40C Z-CW40C G203 Z-C50 SG403C, SG403RC EG403C G403 Z-C60 Z-CV60C Z-CW60C SG603RC SG3RC EG603C EG3C G603 G3 Z-C70 Z-CV70C Ordering information Specify the following: 1. Type number of enclosures Information subject to change without notice /103

21 Steel enclosures Dimensions, mm Standard C With V type handle Z6CV10C to Z-CV40C A D : Z6CV10C : Z6CVC : Z-CV30C, 40C C D A E Mounting hole ø7 2 : Z6CVC to Z-CV40C Mounting hole ø7 : Z6CV10C ø9 : Z6CVC to Z-CV40C 2-øM lead hole OFF RESET TRIP ON E 17 : Z6CVC, Z-CV30C, Z-CV40C 2-ø23 lead hole Earth terminal M6 øm lead hole 4-øM lead hole G Earth terminal M6 I G Z-CV60C, 70C A D 269 C Connection method diagrams a b c Line Line Load d 5 E Line 2-øM lead hole Mounting hole ø12 2-ø28 lead hole Load 4-øM lead hole Load Load Line G Earth terminal M6 Type Z6C10C2 Z6C10C3 Z6CC3 Z6C30C3 Z-C35 Z-C40 Z-C50 Z-C60 Z-C70 Z6CV10C Z6CVC Z-CV30C Z-CV40C Z-CV60C Z-CV70C Connection a, b, c a, b, c, d A C D E G I M (Ø) (kg) , 35 30, 45 30, 45 30, 45 40, 55 40, 55 63, 78, , 35, 43 35, 52, 63 63, 78, /104 Information subject to change without notice

22 Terminal covers Terminal covers Description These terminal covers are used as guards to prevent accidental touch with live line terminations. These terminal covers can be fitted to either line or load side. Up to 2AF Short type Z-TS Snap-on fitting Transparent and black (Z6TS10C only), sealing possible Long type Z-T Crimp connection use Transparent and black (Z6T10C only), sealing possible 400AF and larger Long type Z-T Transparent Short type Long type Packing quantity : 2 pcs. type SG33C SG53C, SG53RC SG63C, SG63RC SG103C, SG103RC EG32AC EG52AC EG33AC, EG33C EG53AC, EG53C EG63C EG102C EG103AC, EG103C G series Terminal cover Short type Z6TS10C2 (lack) Z6TS10C2 (Transparent) Z6TS10C3 (lack) Z6TS10C3 (Transparent) Z-TS30-3 dimension (mm) (g) Terminal cover Long type Z6T10C2 (lack) Z6T10C2 (Transparent) Z6T10C3 (lack) Z6T10C3 (Transparent) Z-T30-3 dimension (mm) (g) SG203C, SG203RC EG203C G53 G103 G203 Z-TS35 Z-TS40 Z-TS Z-T35 Z-T40 Z-T SG403C, SG403RC EG403C G403 Z-T SG603RC SG3RC EG603C EG3C G603 G3 Z-T type SGa104A, SGa104 Terminal cover Long type A1-14 dimension (mm) 28 (g) 60 UL Listed type SG53RCUL SG103CUL EG102CUL EG103CUL Terminal cover Short type Z6TS10C3U (lack)* Z-TS30-3 (g) Terminal cover Long type Z6T10C3U (lack) Z-T30-3 (g) Terminal cover For flat terminal Z-TL30-3 (g) 110 SG203CUL Z-TS40 60 Z-T40 1 Z-TL SG403CUL Z-T Note: * Standard-provided Information subject to change without notice /

23 Insulation barriers Insulation barriers Description The interphase barriers are provided on frame size of 30AF to 400AF breakers for front mounting. The barriers are installed in the molded slots between terminals. The earth barrier is used to increase the insulation with the mounting plate surface when two crimp terminals are wired. Installation of these barriers after wiring is possible even when an external accessory is installed. Interphase barrier Earth barrier Interphase barrier type SG33C SG53C, 53RC SG63C, 63RC SG103C, 103RC SG103CUL EG32AC EG52AC EG102C EG33AC, 33C EG53AC, 53C EG63C EG103AC, 103C G series Interphase barrier Type Dimensions, mm A Z610C Z-30 Z630CU Packing quantity (g) Interphase barrier A SG203C, 203RC EG203C G53 G103 Z-35 Z SG203CUL Z640CU G203 Z SG403C, 403RC, 403CUL SG603RC SG3RC SGa204A, 204 SGa404A EG403C EG603C EG3C G403 G603 G3-43A -44A Earth barrier type SG33C SG53C, 53RC SG63C, 63RC SG103C, 103RC SG203C, 203RC EG32AC EG52AC EG33AC, 33C EG53AC, 53C EG63C EG102C EG103AC, 103C EG203C G series G53 G103 G203 Earth barrier Type Z6L10C2 Z6L10C3 Z-L35 Z-L40 Z-L50 Dimensions, mm* A 43 (50, 75) (30) 1 (75, ) 130 (90, 110) 190 (, 147) 190 (, 147) 43 (30) 70 (40) (50, 72) (50, 72) Packing quantity (g) Earth barrier A Note: * The value in parentheses is the dimensions after the barrier is cut. /106 Information subject to change without notice

Molded Case Circuit Breakers H series General information

Molded Case Circuit Breakers H series General information General information Description Models with high breaking capacities Line protection : 15 to 800A Motor protection : 16 to 5A Molded case color : Black Type number nomenclature Series H: H 5 BA / E Q M

More information

Series. Technical innovation in compact breakers Standard models that fully conform to international standards

Series. Technical innovation in compact breakers Standard models that fully conform to international standards Series EEH 0 The highest priority for the molded case circuit breakers (MCCBs) and earth leakage circuit breakers (ELCBs) employed in power distribution control systems is to provide sure, safe protection

More information

MOLDED CASE CIRCUIT BREAKERS

MOLDED CASE CIRCUIT BREAKERS MOLDED CASE CIRCUIT BREAKERS S series E series Handle-operated type Distribution breakers F series H series Solid-state trip type -pole S and E series INDIVIDUAL CATALOG from D&C CATALOG 9th Edition 0

More information

3VF3 to 3VF8 Circuit-Breakers

3VF3 to 3VF8 Circuit-Breakers 3VF3 to 3VF8 Circuit-Breakers Accessories Operating mechanisms For other s for 3VF3 with knob Rotary drive, complete, scope of supply Cubicle door for 3VF6 Motor operating mechanism for 3VF3 Motor operating

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

HS1B Series Full Size Interlock Switch. GS-ET-15 BG standard in Germany. Part Number Key

HS1B Series Full Size Interlock Switch. GS-ET-15 BG standard in Germany. Part Number Key HSB Series Full Size Interlock Switch HSB features: Rugged aluminum die-cast housing Direct Opening Action: If the door is forced open, the contacts are disconnected even if they are welded or stuck Available

More information

22AF 40AF AF 150AF 225AF 400AF 800AF

22AF 40AF AF 150AF 225AF 400AF 800AF Contactors MC-Series UL508 E108780 Contactor 3 Pole Standards and Certifications UL508 IEC 60947-2 & IEC 60947-4-2 CSA C22.2 No.14 Features 8 Frame Sizes 1/2HP up to 600HP @ 480V AC Screw Terminals (Lug

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

Technical data. Standards: IEC/EN ; EN ISO ; EN 1088; BG-GS-ET-19

Technical data. Standards: IEC/EN ; EN ISO ; EN 1088; BG-GS-ET-19 1 echnical data echnical data, 1 0 3 1 104 7 90 Interlock with protection against incorrect locking hermoplastic enclosure contacts Manual release, emergency exit or emergency release Long life Double

More information

Protection components

Protection components Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed

More information

HS1B R - R. Door Interlock Switches. HS1B Series. HS1B Series Full Size Interlock Switch. Part Number. HS1B features: Part Number Key.

HS1B R - R. Door Interlock Switches. HS1B Series. HS1B Series Full Size Interlock Switch. Part Number. HS1B features: Part Number Key. HSB Series HSB Series Full Size Interlock Switch HSB features: Body Rugged aluminum die-cast housing Direct Opening Action: If the door is forced open, the contacts are disconnected even if they are welded

More information

SD Series Non-Fused Load Switches

SD Series Non-Fused Load Switches SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load

More information

HS2B N B - R. Door Interlock Switches. HS2B Series. Full Size Interlock Switch. Part Number. HS2B features: Part Number Key.

HS2B N B - R. Door Interlock Switches. HS2B Series. Full Size Interlock Switch. Part Number. HS2B features: Part Number Key. HSB Series HSB Series Full Size Interlock Switch HSB features: Body Direct Opening Action: If the door is forced open, the contacts are disconnected even if they are welded or stuck Available with or without

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

HS1E Series Full Size Solenoid Locking Switches

HS1E Series Full Size Solenoid Locking Switches HS1E Series Full Size Solenoid Locking Switches AS-Interface Safety at Work Barriers Enabling Switches Door Interlock Switches X Series E-Stops Overview HS1E features: Basic unit and solenoid unit in one

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

Rotary Cam Switches. Rotary Cam Switches

Rotary Cam Switches. Rotary Cam Switches Rotary Cam es Series... 2 Handle Assemblies... 8 Accessories... 12 Circuit Diagrams, Technical Information & Dimensions (Online)... 13 Series R-Line Rotary Cam es... 24 Handles and Accessories... 27 Circuit

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

WELCOME TO THE WORLD OF COMPLETE AUTOMATION. Innovative MCS Starter Solutions. MCS Starters and the New Mounting System 141A

WELCOME TO THE WORLD OF COMPLETE AUTOMATION. Innovative MCS Starter Solutions. MCS Starters and the New Mounting System 141A WELCOME TO THE WORLD OF COMPLETE AUTOMATION Innovative MCS Starter Solutions MCS Starters and the New Mounting System 141A Welcome to the Wide World of Allen-Bradley Starters Innovative solutions for state

More information

Door Interlock Switches

Door Interlock Switches HSE Series HSE Series Full Size Locking Switches Overview X Series E-Stops HSE features: Basic unit and solenoid unit in one housing Plastic Housing: Light weight Ease of Wiring: All the terminal screws

More information

IP44 - IP66 Rated RCD, Power & Cable Management

IP44 - IP66 Rated RCD, Power & Cable Management IP44 - IP66 Rated RCD, Power & Cable Management IP54 Rated 10 amp Switches IP66 Rated 10 amp Switches IP66 Rated 13 amp Sockets IP66 13 amp RCD switched Socket IP66 13 amp unswitched socket with timer

More information

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC SIRCO PV IEC 609473 The solution for Load break switches > Combiner box > Recombiner box > Inverter sircopv_058_a_1_cat sircopv_059_a_1_cat Strong points Function SIRCO PV are manually operated multipolar

More information

Oiltight Switches & Pilot Devices

Oiltight Switches & Pilot Devices Oiltight Switches & Pilot Devices HW Series 22mm IEC Style Global Pushbuttons Circuit Breakers Terminal Blocks Timers Relays & Sockets Display Lights Switches & Pilot Lights Key features include: Locking

More information

Protection Equipment

Protection Equipment Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection

More information

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004 PRICING October 2004 Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products Class 600 CONTENTS Description Page Multi 9 Supplementary Protectors and Miniature Circuit Breakers.............3

More information

HS6B Series Subminiature Interlock Switch

HS6B Series Subminiature Interlock Switch HS6B Series Subminiature Interlock Switch HS6B features: Only 78 x 30 x 15mm Allows highest level of safety by having 3 contacts: dual load contacts + monitoring contact (ISO13849-1, EN954-1) Two actuator

More information

Installation Instructions for Type SM Safety Handle Mechanism for L-Frame Series C Circuit Breakers and Molded Case Switches

Installation Instructions for Type SM Safety Handle Mechanism for L-Frame Series C Circuit Breakers and Molded Case Switches I.L. 29C284B File 29-000 Installation Instructions for Type SM Safety Handle Mechanism for L-Frame Series C Circuit Breakers and Molded Case Switches DO NOT ATTEMPT TO INSTALL OR PERFORM MAINTENANCE ON

More information

Protection Equipment. 5/2 Introduction

Protection Equipment. 5/2 Introduction Protection Equipment /2 Introduction SIRIUS 3RV2 Motor Starter Protectors/ Circuit Breakers up to 40 A /6 General data /12 For motor protection /14 For motor protection with overload relay function /1

More information

ATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A

ATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A Transfer switches Accessories Terminal shrouds IPX protection against direct contact with terminals or connecting parts. Advantages Perforations allow remote thermographic inspection without the need to

More information

IEC Load Switches Bulletin 194E 25 Amps to 100 Amps

IEC Load Switches Bulletin 194E 25 Amps to 100 Amps Description load switches are designed for use as local motor isolation and IEC disconnect switch applications outside North America. Available with 3- and 6-pole versions with add-on additional poles,

More information

Series L7 Disconnect Switches (to 315A)...L29 Technical Information...L36 Dimensions...L38

Series L7 Disconnect Switches (to 315A)...L29 Technical Information...L36 Dimensions...L38 Series 7 Motor (to 100A)...2 Series 7 Enclosed (to 100A)...14 Technical Information...18 Dimensions...22 Series 7 (to 315A)...29 Technical Information...36 Dimensions...38 Series 10 Fusible and Non-Fusible...45

More information

Industrial Control Transformers

Industrial Control Transformers 6 Industrial Control Transformers Section 6 Industrial Control Transformers provide a low and safe control voltage for the operation of electromagnetic devices, such as motor starters, contactors, solenoids

More information

HS1E Series Full Size Interlock Switch with Locking Solenoid

HS1E Series Full Size Interlock Switch with Locking Solenoid HS1E Series HS1E Series Full Size Interlock Switch with Locking Solenoid HS1E Key features include: Basic unit and solenoid unit in one housing Plastic Housing: Light weight Ease of Wiring: All the terminal

More information

CIRCUIT PROTECTORS LOW VOLTAGE FUSES AIR CIRCUIT BREAKERS

CIRCUIT PROTECTORS LOW VOLTAGE FUSES AIR CIRCUIT BREAKERS CIRCUIT PROTECTORS LOW VOLTAGE FUSES AIR CIRCUIT BREAKERS Circuit protectors Circuit protectors Air circuit breakers Air circuit breakers AFaC and BaC types HRC fuses BLC, CR and CS types Super Rapid Fuses

More information

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified

More information

SIRCOVER. Manual Transfer Switching Equipment from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for.

SIRCOVER. Manual Transfer Switching Equipment from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for. Transfer switches svr_151_a The solution for > Manufacturing > Power distribution SIRCOVER 250 Strong points svr_214_a > Complete range > Easy to connect > Stable positions > On-load switching Conformity

More information

Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models

Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models Enclosed Switch Economical, High Utility Enclosed Switch High precision and long life (10,000,000 mechanical operations) through employment of the moving spring used in OMRON Z Basic Switch. Sealed with

More information

LDisconnect Switches. Disconnect Switches

LDisconnect Switches. Disconnect Switches Disconnect Switches Disconnect Switches Series 7 - Motor Disconnect Switches up to 100A...2 Handles & Accessories...10 Series 7 Enclosed Disconnect Switches...14 Technical Information...20 Dimensions...22

More information

Push Button Units and Indicator Lights

Push Button Units and Indicator Lights 3SB3, Inscriptions, 22 mm Insert labels Push Button Units and Indicator Lights Push buttons (clear) and illuminated push buttons with a flat button can be fitted with insert labels for identification purposes,

More information

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00, Low-Voltage Controls and Distribution > Industrial Controls > Protection Equipment > Circuit Breakers/Motor Starter Protectors > Motor Starter Protectors SIRIUS RV up to 00 A RV0-0DA5 CIRCUIT-BREAKER,

More information

Pushbuttons/Selectors/Pilot Lights AH25 General information

Pushbuttons/Selectors/Pilot Lights AH25 General information Pushbuttons/Selectors/Pilot Lights AH5 General information Features Oil and dust-proof construction Protection complies with IEC Standard IP65.Special seals keep out oil, water, dust, and chips. This gives

More information

EXCEL CELL ELECTRONIC CO., LTD. NO. A S P E C I F I C A T I O N Edition 2 Page 1

EXCEL CELL ELECTRONIC CO., LTD. NO. A S P E C I F I C A T I O N Edition 2 Page 1 S P E C I F I C A T I O N Edition 2 Page 1 ECS - INDUSTRIAL CONTROL SWITCH SELECTOR 1. FEATURES Up to 5 different operations. Detachable contact block for easy installation and removal. It can meet variety

More information

Oiltight Switches & Pilot Devices

Oiltight Switches & Pilot Devices Oiltight Emergency Stop Stations Part Numbers: Emergency Stop Stations Description Contacts Plastic Bezel Metal Bezel Ø 40mm Pushlock Turn Reset 1NO-1NC HW1X-BV411-R* HW4X-BV411-R* 2NC HW1X-BV402-R* HW4X-BV402-R*

More information

Safety Products. Safety Products. HS5E Series. HS5E Series Miniature Solenoid Locking Switch

Safety Products. Safety Products. HS5E Series. HS5E Series Miniature Solenoid Locking Switch HS5E Series HS5E Series Miniature Solenoid Locking Switch HS5E Key features include: World s smallest 4 contact solenoid interlock switch. (35 40 46 mm.) Four contacts. Gold-plated contacts. Spring lock

More information

High barriers Recognized by UL and cul Self-extinguishing materials Nonferrous material Corrosion-resistant nickel finish Safety-grip handle A complete line of switches is available for meter, relay, instrument,

More information

HS5E Series Miniature Solenoid Locking Switches

HS5E Series Miniature Solenoid Locking Switches HS5E Series Miniature Solenoid Locking Switches AS-Interface Safety at Work Barriers Enabling Switches Door Interlock Switches X Series E-Stops Overview HS5E features: World s smallest 4 contact solenoid

More information

HMI Components. Series. Indicator Illuminated pushbutton Mushroom-head pushbutton Key lock switch

HMI Components. Series. Indicator Illuminated pushbutton Mushroom-head pushbutton Key lock switch Edition 10/2016 HMI Components Series Characteristics The compact Series is especially suited for: Flush design The large rectangular design (24x36mm) features a large illuminated area. Functions The Series

More information

Low Voltage Fuses General information

Low Voltage Fuses General information General information Description FUJI low voltage current-limiting fuses are designed to give protection to power supply and distribution circuits and equipment such as motor starter and semiconductors.

More information

PKZ and PKE motor-protective circuit-breakers

PKZ and PKE motor-protective circuit-breakers PKZ and PKE motor-protective circuit-breakers Machinery and installation downtimes should be kept as short as possible. The PKZ fuseless motor-protective circuit-breakers combine short-circuit and overload

More information

SENTRON VL Series Product Specifications

SENTRON VL Series Product Specifications SENTRON VL Series Product Specifications VL 400 Frame 400 s Electronic Releases ETU TRIP RELEASE 315 12-315 3VL4731 - A 3-0AA0 400-400 3VL4740 - A 3-0AA0 3 = 3 poles All VL400 circuit-breakers are shipped

More information

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Thermal-magnetic Miniature Circuit Breaker 4230-T... Thermal-magnetic Miniature Circuit Breaker 420-T... Description Single pole and multipole thermal-magnetic miniature circuit breakers (MCBs) in accordance with EN 60947-2, UL 077 and UL 489 for DIN rail

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

Door Interlock Switches

Door Interlock Switches HS5B Series HS5B Series Miniature Interlock Switch HS5B features: mm x mm x 9mm Compact Housing Available with Contact Confi gurations (NO + NC or NC) Flexible Installation: By turning the head of the

More information

Limit Switches and Safety

Limit Switches and Safety and Safety Introduction Overview 3SE5 23., 3SE5 21. 3SF1 2.4 3SE5 24., 3SF1 244 3SE5 13., 3SE5 11., 3SF1 114 3SE5 12., 3SF1 124 3SE5 16. 3SE5 232, 3SE5 212, 3SF1 2.4 3SE5 132, 3SE5 112, 3SF1 1.4 Position

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

HEAVY DUTY POWER RELAYS FEATURES

HEAVY DUTY POWER RELAYS FEATURES VDE VC HEAVY DUTY POWER RELAYS VC RELAYS Faston terminal Screw terminal mm 9 FEATURES VC power relays are designed for controlling heavy duty loads safely: Contact gap of 3 mm or more -point contacts for

More information

ATX DPD Series Distribution Panelboards Flameproof

ATX DPD Series Distribution Panelboards Flameproof ATX DPD Series Distribution Panelboards Applications Protection and control of electrical equipment in hazardous areas where ignitable vapors, gases or highly combustible dusts are present. For installation

More information

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

The breakers offer thermal-magnetic trip protection according to Z and K characteristics. Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific

More information

IEC Power Control SIRIUS. Motor Starter Protectors. Revised 04/20/15. Section Overview... 1/2-1/3. Motor Starter Protectors

IEC Power Control SIRIUS. Motor Starter Protectors. Revised 04/20/15. Section Overview... 1/2-1/3. Motor Starter Protectors 04/20/15 IEC Power Control Motor Starter Protectors Contents Pages Section Overview......................... 1/2-1/3 Motor Starter Protectors 3RV20 MSP, Class 10/20.................... 1/4-1/5 3RV10 MSP,

More information

Design Standard. Purpose: Design Standard:

Design Standard. Purpose: Design Standard: Design Standard Purpose: This design standard has the purpose of creating a consistent application of motor-control centers throughout the East Side Union High School District, therefore achieving a standard

More information

HS6B Series Sub-Miniature Interlock Switch. Direct Opening

HS6B Series Sub-Miniature Interlock Switch. Direct Opening HS6 Series HS6 Series Sub-Miniature Interlock Switch HS6 Key features include: Only 30mm x 15mm x 78mm Allows highest level of safety by having 3 contacts: dual load contacts + monitoring contact (ISO13849-1,

More information

SIRCOVER. Manual transfer switches from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for. Strong points

SIRCOVER. Manual transfer switches from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for. Strong points Transfer switches svr_151_a The solution for > Manufacturing industry > Power distribution SRCOVER 2 Strong points > complete range > Easy connections > Stable positions svr_125_a_1_cat Bypass TS 0 Conformity

More information

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information Safety-door Switch Safety-door Switch s Special Operation Key Directly Pulls Apart the Contacts from Each Other and Contributes to the Safety of the Production Site Conforms to EN (TÜV) standards corresponding

More information

Rotary Cam Switches. Rotary Cam Switches

Rotary Cam Switches. Rotary Cam Switches es Series es... 2 Assemblies... 11 s... 15 Accessories... 25 Technical Information... 26 Dimensions... 31 Series R-Line es... 34 s... 39 Accessories... 40 Technical Information... 41 Dimensions... 42 es

More information

Operator s Manual Series ATB Automatic Transfer & Bypass Isolation Switches 150, 260, and 400 amp sizes A. Rating Label.

Operator s Manual Series ATB Automatic Transfer & Bypass Isolation Switches 150, 260, and 400 amp sizes A. Rating Label. Operator s Manual 7000 Series ATB Automatic Transfer & Bypass Isolation Switches 150, 260, and 400 amp sizes TABLE OF CONTENTS Note: Refer to the outline and wiring drawings provided with your 7000 Series

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays New generation of Contactors from LS Industrial Systems Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol

More information

Low voltage circuit breakers

Low voltage circuit breakers Comprehensive Catalogue 2006 Super Solution Low voltage circuit breakers A-3. Accessories TD & TS MCCB Index Electrical auxiliaries Undervoltage release, UVT Shunt release, SHT Auxiliary switch (AX),

More information

ø12 A2 Series Miniature Control Units

ø12 A2 Series Miniature Control Units ø2 A2 Series Miniature Control Short 22-mm-long body miniature control unit series with bright LED illumination face and snap-action switching. Degree of protection: IP40 and IP5 (IEC 0529) All series

More information

XCS Safety Interlock Selection

XCS Safety Interlock Selection Steven Engineering-2 Ryan Way-South San Francisco, CA 980-6370-Main Office:(650)588-9200-Outside Local Area:(800)258-9200-www.stevenengineering.com Selection Plastic, Double, Turret Head c, Type, locking

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information

Just the right switch for your application

Just the right switch for your application Series 7 Motor Disconnect Switches up to 100A U508 approved device suitable as motor disconnect TIP! Sprecher + Schuh s 7 line incorporates the latest modular design techniques to provide maximum functionality

More information

Safety Door Handle System with SIDENT Safety Switch Ref. no , -11, -12

Safety Door Handle System with SIDENT Safety Switch Ref. no , -11, -12 Safety Door Handle System TGY with SIDENT Safety Switch Ref. no. 43.20-01 07, -11, -12 1. Purpose Automated systems with dangerous machine functions require guards to ensure that the operating personnel

More information

Motor Starter Protectors

Motor Starter Protectors Motor Starter Protectors Industrial Controls Product Catalog 207 Section contents Section Overview /2 - /3 Motor Starter Protectors 3RV20 MSP, Class 0/20 /4 - /5 Circuit Breakers 3RV27, 3RV28 Circuit Breaker

More information

Direct Coupled Damper Actuator Model MY6050A1001

Direct Coupled Damper Actuator Model MY6050A1001 Specifications/Instructions Direct Coupled Damper Actuator General direct coupled damper actuator is a motorized actuator to open/close a damper. Model MY6050A00 provides -position or floating control

More information

Motor Circuit Breakers C3

Motor Circuit Breakers C3 Motor Circuit Breakers C3 Motor protection rating up to 100 Amps Short circuit breaking capacity up to 100kA Phase failure protection DIN rail mounting Wide range of accessories Options and ordering codes

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

SOLENOID VALVES, SERIES

SOLENOID VALVES, SERIES VALVES GENERAL CATALOG SOLENOID VALVES, SERIES INDEX Features 365 Basic Models and Configuration 366 Solenoid Valve Order Codes 367 Manifold Order Codes 368 112 Series Specifications 369 Operating Principles

More information

Motor Controllers + Circuit Breakers

Motor Controllers + Circuit Breakers Series General...2 Series & KTA3-100 Base Units...4 Series Base Units...6 Series Base Units...8 Accessories...10 Technical Information -...20 Dimensions -...33 Technical Information - KTA3-100...39 Dimensions

More information

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism

More information

Load Break Disconnect Switches FSLBS

Load Break Disconnect Switches FSLBS Load Break Disconnect Switches FSLBS UL 508 Non-Fused Load Break Switches The FSLBS Load Break Switch is a newly designed industrial-grade switch capable of making or breaking loads up to 600V. It is suitable

More information

Bulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents

Bulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents Bulletin IEC Non-Reversing Starters Product Overview/Product Selection Cat. No. -CABAF--R-P IP (Type ) Metal Enclosure with Lift-off Cover Bulletin IEC Non-Reversing Starters Impact-resistant molded enclosures

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC Non-Fused Load Break Switches FSSC, SX, SXDC, SC UL 98 Non-Fused Load Break Switches Mersen disconnect switches are extremely durable, manually operated, non-fused disconnect switches. These heavy-duty

More information

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage SENTRON Configuration Manual Edition 10/2015 siemens.com/lowvoltage 2 Introduction LD main control and EMERGENCY-STOP switches up to 250 A 4 Introduction 7 Front mounting 10 Floor mounting 11 Distribution

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

Series VQ Port Solenoid Valve

Series VQ Port Solenoid Valve Port Solenoid Valve Series VQ00 Outstandingly high speed, stable response, and long service life. ON:. ms, OFF: ms, Dispension accuracy ms (; supply pressure 0. MPa) 00 million cycles or more (Factors

More information

GKR/GKL Series Dual Entry Solenoid Key Operated Safety Interlock Switch

GKR/GKL Series Dual Entry Solenoid Key Operated Safety Interlock Switch Series Dual Entry Solenoid Key Operated Safety Interlock Switch FEATURES Solenoid power to lock or power to unlock Side or top key entry Separate switches for key position and solenoid status Available

More information

SIRIUS 3RU2 Thermal Overload Relays

SIRIUS 3RU2 Thermal Overload Relays Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors. The overload relay can be connected directly to

More information

RU Series Universal Relays

RU Series Universal Relays Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator available on plug-in relays No internal

More information

System pro M compact Miniature Circuit Br eakers Description Features

System pro M compact Miniature Circuit Br eakers Description Features System pro M compact Miniature Circuit reakers S0 Series Description Increasing energy requirements result in larger short-circuit currents which place heavy demands on protective switchgear regarding

More information

Starters. Across the line. Across the line starters Open & enclosed A9 AF750. Description A9 AF750. Starters. Enclosure types

Starters. Across the line. Across the line starters Open & enclosed A9 AF750. Description A9 AF750. Starters. Enclosure types Across the line starters & enclosed A9 AF750 Across the line Description A9 AF750 Maximum UL horsepower ratings UL508A Panel Program, #E105450 NEMA s (00 7) available Compact space-saving design Standard

More information

D509E. Manual Motor - Starters

D509E. Manual Motor - Starters D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors

More information

A22/M22. Specifications. Specifications Common to All. Complete Assemblies

A22/M22. Specifications. Specifications Common to All. Complete Assemblies Complete Assemblies Specifications Common to All A22/M22 The Following Pages Provide Information Common To Each Model of The A22/M22 Pushbutton Switch H A22 H A22S/W H A22K H M22 Specifications J APPROVED

More information

Motor Circuit Breakers C4

Motor Circuit Breakers C4 Motor protection rating up to 100 Amps Short circuit breaking capacity up to 100kA Phase failure protection DIN rail mounting Wide range of accessories Options and ordering codes Model C4/32T Setting Short

More information

4 - Miniature controls

4 - Miniature controls Index -....1.22 Selection Contactors for connection to PLCs, B6S & B7S, 3 phase...6 Contactors, Interface, B6 & B7, 3 phase...5 Contactors, features...1 Contactors, mechanically interlocked, B6 & B7, 3

More information

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure. Guard Lock Safety-door Switch Protective Doors Are Locked Until Machines Completely Stop Operating A mechanical lock is applied automatically when the Operation Key is inserted. A high level of safety

More information

Cutler-Hammer. Instructions for Potential Transformer and Auxiliary Control Power Disconnecting Means for Use in Ampgard Lineups, 7.2 kv I.B.

Cutler-Hammer. Instructions for Potential Transformer and Auxiliary Control Power Disconnecting Means for Use in Ampgard Lineups, 7.2 kv I.B. Cutler-Hammer Instructions for Potential Transformer and Auxiliary Control Power Disconnecting Means for Use in Ampgard Lineups, 7.2 kv DANGER HAZARDOUS VOLTAGE. READ AND UNDERSTAND THIS BOOKLET IN ITS

More information

NEMA Contactors & Starters (Freedom)

NEMA Contactors & Starters (Freedom) Page 1 February, 1 Supersedes TIP AN1, AN, CN1, CN Pages 1-0, Dated 1/1/4 ECN01, ECN0, ECN0, ECN0, ECN0 AN1, AN, CN1 & CN Sizes 00-, 00V Max. Non-Reversing & Reversing NEMA Type Enclosures 1, R, 4X & 1

More information