MOLDED CASE CIRCUIT BREAKERS

Size: px
Start display at page:

Download "MOLDED CASE CIRCUIT BREAKERS"

Transcription

1 MOLDED CASE CIRCUIT BREAKERS S series E series Handle-operated type Distribution breakers F series H series Solid-state trip type -pole S and E series INDIVIDUAL CATALOG from D&C CATALOG 9th Edition 0 Revised Motor operated breakers LOW VOLTAGE EQUIPMENT Up to 0 Volts

2 D & C CATALOG DIGEST INDEX Individual catalog No. LOW VOLTAGE PRODUCTS Up to 0 Volts 0 0 Magnetic Contactors and Starters Thermal Overload Relays, Solid-state Contactors DUO series Manual Motor Starters and Contactors Combination Starters 0 Industrial Relays, Industrial Control Relays Annunciator Relay Unit, Time Delay Relays Electronic Counters 0 Pushbuttons, Selector Switches, Pilot Lights Rotary Switches, Cam Type Selector Switches Panel Switches, Terminal Blocks, Testing Terminals 0 AS-Interface, Limit Switches Proximity Switches Photoelectric Switches 0 Molded Case Circuit s 07 Earth Leakage Circuit s Earth Leakage Protective Relays 0 Circuit Protectors Low Voltage Current-Limiting Fuses Air Circuit s 09 Measuring Instruments, Arresters, Transducers Power Factor Controllers Power Monitoring Equipment (F-MPC) AC Power Regulators Noise Suppression Filters Control Power Transformers HIGH VOLTAGE PRODUCTS Up to kv Disconnecting Switches, Power Fuses Air Load Break Switches Instrument Transformers VT, CT Vacuum Circuit s, Vacuum Magnetic Contactors Protective Relays

3 0 Molded Case Circuit s Molded Case Circuit s General information... 0/ Design features... 0/ Breaking capacities... 0/7 Quick reference guide Line protection S series... 0/ E series... 0/ L, H series... 0/ Motor protection S series... 0/ E series... 0/7 L, H series... 0/ UL Listed... 0/9 Mounting modification... 0/ Terminal connection... 0/9 Wire size and terminal... 0/0 Type number nomenclature... 0/ Type number Line protection S series... 0/ E series... 0/ L, H series... 0/ Motor protection S series... 0/9 E series... 0/ L, H series... 0/ UL Listed... 0/ Dimensions... 0/ Characteristic curves... 0/79 Accessories... 0/ Internal accessories... 0/90 Motor-operated breakers... 0/ Mechanical interlocking device... 0/ Operating handles... 0/ Steel enclosures... 0/ Terminal covers... 0/ Insulation barriers... 0/9 Mounting modification kits... 0/ Padlocking device... 0/ Distribution breakers F series... 0/ Solid-state trip types... 0/ CCC approved... 0/0 Page

4 MINIMUM ORDERS Orders amounting to less than,000 net per order will be charged as,000 net per order plus freight and other charges. WEIGHTS AND DIMENSIONS Weights and dimensions appearing in this catalog are the best information available at the time of going to press. FUJI ELECTRIC FA has a policy of continuous product improvement, and design changes may make this information out of date. Please confirm such details before planning actual construction. INFORMATION IN THIS CATALOG IS SUBJECT TO CHANGE WITHOUT NOTICE.

5 Molded Case Circuit s General information Description The highest priority for the molded case circuit breakers (MCCBs) and earth leakage circuit breakers (ELCBs) employed in power distribution control systems is to provide sure, safe protection for connected equipment against short-circuits or earth leakage. Fuji Electric FA has led the industry with the s (0 to 00AF), same-size MCCBs and ELCBs. All of these breakers meet exacting demands for quality and performance. Now, the lineup has been further enhanced with six major concepts international standardization, utility, technical innovation, compactness, safety and ecology in the series. Outstanding features s employ a new current-limiting mechanism based on the arc-driving technique for highspeed contact opening and very short arcing time. This, and a dual-latching mechanism, enable 0AF and AF MCCBs to interrupt current faster at higher capacities. A special resin with excellent thermal and mechanical properties produces a more compact molded case for higher breaking capacity. Standardized modular construction Standardized dimensions ease panel design and manufacture. Models 0AF to AF are mm deep and require a panel cutout height of mm. Models 00AF to 00AF are mm deep and require a panel cutout height of 9mm. With standardized modular construction, s cut panel manufacturing costs. A wider range of customermountable accessories The range of cassette-type internal accessories has been greatry expanded for 0AF to 00AF MCCBs. This speeds up and simplifies customer response to specification changes. All accessories shown here can be mounted by the customer except for motor operating mechanism and plate type padlocking device. Conforming to international standards The series conforms to IEC and EN standards, and features UL, cul and CCC. Compliance with EN Standards FUJI's MCCBs conform to the European Standards for circuit breakers (EN97- = IEC97-). (E and S series, 0AF to 00AF only) 0 Types of MCCBs Line protection For general-purpose circuit protection This type of MCCB may be employed in both main and branch circuits. They are installed in motor control centers and distribution boards to provide protection from both overload and short-circuit currents. The overcurrent trip mechanism of the general-purpose MCCB consists of thermal and magnetic elements. Thermal trip action and magnetic trip action provided overcurrent protection and short-circuit protection, respectively. For distribution boards These MCCBs are used exclusively in branch circuits of distribution boards for lighting installations. These breaker are compact and suitable for mounting in groups. These circuit breakers are available in and AF (Ampere Frame) types, and their breaking capacities are within the.ka to.ka range. Motor-protection The line current ratings of MCCBs for motor protection are equal to the motor s full-load current to provided motor overload and line overcurrent protection. These MCCBs obviate the need for magnetic motor starters. Since these MCCBs control motor start-stop operation, they must be used with loads which do not require frequent switching. These MCCBs handle starting rush currents of up to 0% and enable starting times of up to two seconds. These MCCBs are for generalpurpose, -phase squirrel-cage induction motors with direct-on-line starting. Solid-state trip These solid-state trip type MCCBs incorporate a trip device with a built-in microprocessor. Rated current levels can be selected in five to six steps, and a wide variety of tripping parameters, including long-time delay, short-time delay, and instantaneous tripping, can be set with high precision. These MCCBs are ideal for providing selective trip protection coordination with various protective devices, such as fuses and other MCCB units. This type of MCCB also increases the reliability of the power supply. 0/

6 Molded Case Circuit s General information Models and applications CE marking Line protection S series E series Motor protection S, E series UL approved UL9 Listed S-UL, E-UL series Used for equipment with a capacity range of to 0kVA. Satisfies EN (IEC) standards and bears CE markings. Ideal for circuits with comparatively low short-circuit current. Satisfies EN (IEC) standards and bears CE markings. Enables the design of compact, economical control panels. The depth is mm for types with a capacity range of 0 to A. This breaker protects motors from overload and cables from excessive current. This breaker is UL and CSA approved. Satisfies EN (IEC) standards and bears CE markings. Varieties of MCCBs IEC and CE marking conformed Frame size 0AF AF AF AF AF 00AF 0AF 00AF Line protection S series SA0C -CE SAC -CE SARC -CE SAC -CE SARC -CE SAC -CE SARC -CE SAC -CE SARC -CE SA00C -CE SA00RC -CE SA0RC -CE SA00RC -CE E series EA0AC -CE EAAC -CE EAC -CE EAC -CE EAAC -CE EAC -CE EAC -CE EA00C -CE EA0C -CE EA00C -CE Motor protection S series SA0CM -CE SACM -CE SARCM -CE SACM -CE SACM -CE SARCM -CE SACM -CE SARCM -CE E series EA0ACM -CE EACM -CE EACM -CE EACM -CE EACM -CE Note: Type number with "-CE" indicates the IEC and CE marking conformed model, but type number without "-CE" indicates also the same. UL9 Listed Frame size 0AF AF AF AF AF 00AF 0AF 00AF UL9 Listed SA-UL SARCUL SACUL SARCUL SACUL SARCUL SA00CUL SA00RCUL SA0RCUL SA00RCUL EA-UL EACUL JIS C70 Frame size 0AF AF AF AF AF 00AF 0AF 00AF S series L series H series LAB HC HC HR HC HR H00C H00R H0C H0R H00C H00R -pole F series 0/ SAB FB FB FB Note: Solid-state trip type is also available. SA0E, E, E EAB SAR FB FB SA0R SA0HA SAH SA0H

7 Molded Case Circuit s Design features Design features Direct-Drive switching mechanism A vertical link mechanism is used for the switching mechanism to reduce the torque of the moving contact arm, serve as a countermeasure against increased contact opening distance, and improve contact opening speed. Handle Latch Contact opening distance/moving contact arm torque Moving contact arm torque 0 Conventional MCCB Contact opening distance Moving contact arm High-performance arc quenching chamber The combination of the simple Flat Turn contact arm, blowout magnet, and arc-quenching chamber provided a unique current-limiting effect. Moving contact 0 Flat-Turn contact Arc quenching chamber Blow-out magnet Structure of the arc-quenching chamber Blow-out magnet Arc between contacts Moving contact Blow-out gas Blow-out gas Arc driving force Comparison of arc voltages resulting from short-circuit current Trip button 0Arc voltage Conventional MCCB Time The MCCB can be mechanically tripped externally. 0/

8 Molded Case Circuit s Design features Model configuration Model configuration Standardization of the main dimensions of the MCCB s has a large effect on panel design, manufacturing and appearance. Modular construction Standardized modular construction 0AF to 00AF s standardized basic dimensions panel design and cutouts are simplified for manufacturing cost savings. The number of mounting space sizes for the 0AF to 00AF S and E series models has been reduced to. New s are available in two standard depths: and mm, choose it from two front panel cutout height of mm or 9mm. The operating handle is at the center of the breaker and its panel cutout for eased panel design, manufacture, and mounting are easy. Terminal height above the panel of models 0AF to AF is standardized at mm to ease wiring. Panel cutout, 9mm Side-by-side installation A pole width of mm was selected for distribution panel breakers and economy type general-purpose breakers with frame size of A and smaller. Therefore, extremely rational procedures can be devised for panel machining and wiring. Thin terminal block The terminal block for internal accessory is now thinner (/ the size of conventional type). Thus, the space between breakers has been reduced to less than / that required by conventional type. (EAAF or smaller) Compact and lightweight These breakers are more compact and lightweight than those of the old series. Photos are a comparison of new EAC breakers and old EAB. Compact and lightweight OLD NEW 7mm EAB mm % reduced mm Depth, mm Terminal height mm (Up to AF) CP-9 7mm EAC The standardization of depths reduces the number of frame sizes from to. Conventional series dimensions (0AF to 00AF) (mm) EA0 EAA EAF SA0B SAB SAR SAB SAR EAB EAB EAB SABA SARA SABA SARA EAB SA00B EA00B SA0R EA0B SA00R SA00R EA00B -TWIN series dimensions SA0C SAC SARC SAC SARC EA0AC EAAC EAC EAC EAAC EAC SAC SARC SAC SARC EAC SA00C EA00C SA0RC EA0C SA00RC SA00RC EA00C Note : The figures show the dimensions of three-pole models 0/

9 Molded Case Circuit s Design features Terminal construction Front mounting front connection main types of terminals are as shown in the photos. Terminal screws are self-lifting, pan-head screw, hexagonal socket head screw and flat terminal which are tighten because bolts are used. Terminals vary according to the current capacity of each type of housing. All breaker terminals should be connected to copper crimp connectors or copper bus bars. Never connect to aluminium conductors, since overheating can be expected. Self-lifting terminal NA-007 Terminal covers Since the live conductors are exposed at the MCCB terminals there is the danger of accidental contact. A terminal cover can be provided where necessary. For further information refer to page 0 /. Short type Modular design Up to AF E and S series ( series) Since molded cases generally have comon dimensions and outlines they can easily be installed on distribution boards in uniform neat groupings, with switches lined up in a row. E and S series up to AF are built on the modular system. For instance the depth is mm while the panel cutout height of mm. The standardization of the MCCBs and panel board allows the speed up of assembling and wiring of the panel and permits panel surface processing to be carried out in a shorter period of time. Long type Screw terminal (Pan-head bolt) 0 NA-00 SA0C SAC SARC SAC SARC SAC SARC EAC Panel cutout height mm Screw terminal (Hexagonal socket head bolt) EA0AC EAAC EAC EAC EAC EAAC SAC SARC Depth mm FB FB Flat terminal SDO-090M 0/

10 Molded Case Circuit s Design features Accessories Internal and external accessories A wider range of customer-mountable accessories The range of cassette-type internal accessories has been greatly expanded for MCCBs. This speeds up and simplifies customer response to specification changes. All accessories shown here can be mounted by the customer except for motor operating mechanism and plate type padlocking device. Wide variety of internal accessory combinations Up to two auxiliary switches, two alarm switches, and one shunt trip device or undervoltage trip device quickly snap on or in. Quick and easy mounting No need to open breaker cover to mount accessories. Internal accessories easily snap into a pocket at the left of the breaker window frame. No adjustments Accessory mounting is quick and easy accessories adjust automatically at the correct position when mounted. Two ways to connect lead wires or terminal blocks Lead wire types Leads are marked with to indicate the correct terminal number of the accessory incorrect wiring is minimized. To make wiring easy and prevent to incorrect connection, the lead wires are provided with color coated tube and marking on it. AF9- Terminal block types Terminal blocks are mounted on the side of the breaker case. Blocks are only. or 9mm thick, minimizing panel mounting space. Installed lead wires are parallel to the side of the case. AF9- Alarm switch Auxiliary switch Shunt trip device Undervoltage trip device Terminal block Terminal covers Long type Short type Insulation barriers Interphase barrier Earth barrier Motor operating mechanism Mechanical interlocking device Steel enclosure Handle padlocking device Handle locking cover Operating handles N type V type Modification kits For front mounting, rear connection For plug-in mounting For flush mounting, rear connection 0/

11 Molded Case Circuit s Breaking capacities IEC97-, JIS C0- / IEC and CE marking conformed Series ampere frame Basic type Pole Rated current (A) Insulation voltage Ui (V) Breaking capacity (ka)[icu/ics] IEC97 JIS C0- AC DC 0V 0V 00V V 0V 0V 0V V S 0 0 SAC -CE SAC -CE,,,, 0, 0,,,, 0, 0 / /././././././././././././ SAC -CE SAC -CE SARC -CE SARC -CE,,, 0, 0, 0,,,, 0, 0, 0,,, 0, 0, 0,,, 0, 0, 0, / / / / 7./ 7./ / / 7./ 7./ / / 7./ 7./ / / 7./ 7./ / / / / 7./ 7./././ / / / / / / SAC -CE SAC -CE SARC -CE SARC -CE / / / / 7./ 7./ / / 7./ 7./ / / 7./ 7./ / / 7./ 7./ / / / / 7./ 7./././ / / / / / / SAC -CE SAC -CE SARC -CE SARC -CE, 0, 0, 0,,, 7,, 0, 0, 0,,, 7,, 0, 0, 0,,, 7,, 0, 0, 0,,, 7, / / / / 0/ 0/ / / 0/ 0/ / / 0/ 0/ / / /7 /7 / / / / 0/ 0/ / / 0/0 0/0 SA0C -CE SA0C -CE SA0RC -CE SA0RC -CE,, 7, 00,,, 7, 00,,, 7, 00,,, 7, 00, / / / / 0/ 0/ / / 0/ 0/ / / 0/ 0/ / / /7 /7 / / / / 0/ 0/ / / 0/0 0/ SA0C -CE SA0C -CE SA0RC -CE SA0RC -CE, 00,, 00, 00,, 00, 00,, 00, 00,, 00 / / / / / / / / / / / / / / / / / / / / / / / / 0/ 0/ 0/ 0/ 0/0 0/ SARC -CE SA0RC -CE 0, 0 700, 00 / / / / / / / / / / / / 0/ 0/ 0/0 0/0 E 0 0 EAAC -CE EAAC -CE,,,, 0, 0,,,, 0, /./././././././././ EAAC -CE EAAC -CE EAC -CE EAC -CE,,, 0, 0, 0,,,, 0, 0, 0,,,, 0, 0, 0,,,, 0, 0, 0, 0 0././ / /././././././././././././././././././././ EAC -CE EAC -CE / / / /././././././././././ EAAC -CE EAC -CE EAC -CE, 7,,, 7,,, 7, 0 / / /./ / /./ / / / / / / 7./ 7./ / / / / EA0C -CE EA0C -CE,, 7, 00,,, 7, 00, / / / / / / / / / / / / / / EA0C -CE EA0C -CE, 00,, 00, 00,, 00 / / / / / / / / / / /9 /9 0/ 0/ 0 00 EAC -CE EA0C -CE 0, 0 700, 00 / / / / / / / / / / / / 0/ 0/ Note: For details of breaking capacity, see page 0 / "Quick reference guide". Series ampere frame Basic type Pole Rated current (A) Insulation voltage Ui (V) Breaking capacity (ka)[icu/ics] IEC97- AC 0V 00V 0V 0V 0V DC V S 0 SAE SAE SAE SAE SAE SAE /7 /7 /7 /7 /9 /9 /9 /9 /9 /9 / / /9 /9 /9 /9 / / / / / / /9 /9 /9 /9 /9 /9 / / 0/7

12 Molded Case Circuit s Breaking capacities JIS C70 Series ampere frame Basic type Pole Rated current (A) Insulation voltage Ui (V) Breaking capacity (ka) AC 0V 0V 0V V 0V 0V V DC V H HR H0R 0,,, 7,,, 7, 00, 0 0 Series ampere frame Basic type Pole Rated current (A) Insulation voltage Ui (V) Breaking capacity (ka) AC 0V 0V 0V V 0V 0V V DC V S SAB SAR,,, 0, 0, 0,, 0, 0, 0,,, 7, SA0R SA0HA, 7, 00, 00,, SAH SA0H S S 0, 0 700, E EAB,, 7, 7. F FB FB FB, 0, 0, 0,, 0, 0, 0,, 0, 0, 0, FB FB, 7,, 7, /

13 Molded Case Circuit s Breaking capacities IEC 97- Series ampere frame Basic type Pole Rated current (A) Insulation voltage Ui (V) Breaking capacity (ka)[icu/ics] IEC97- AC 0V 00V 0V 0V 0V DC V L LAB, / /0 / / H HBA HBA, 0, 0, 0,, 0, 0, 0, / / /7 /7 /7 /7 /9 /9 /7 /7 0/ 0/ HBA HBA, 0, 0, 0,,, 7,, 0, 0, 0,,, 7, / / /7 /7 /7 /7 /9 /9 /7 /7 0/ 0/ H0BA H0BA,, 7, 00,,, 7, 00, / / /7 /7 /7 /7 /9 /9 /7 /7 0/ 0/ H0B H0B H0R, 00,, 00, 00,, 00, 00,, 00 / / / / / / / / / / / / / / 0/0 0/0 0/0 0 0 HB HR 0, 0 0, 0 / / / / / / / / / 0/0 0/ H0B H0R 700, , 00 / / / / / / / / / 0/0 0/0 UL9 Listed Series ampere frame Basic type Pole Rated current (A) Insulation voltage Ui (V) Breaking capacity (ka)[icu/ics] IEC97 JIS C0- AC DC 0V 0V 00V V 0V 0V 0V V UL9 (cul) Rated voltage Breaking capacity (ka) (V) 0 0Y/ S SARCUL SARCUL,,,, 0, 0, 0,,,,, 0, 0, 0, / / / / / / / / / / 7./ 7./ / / 0 0 SACUL SACUL SARCUL SARCUL, 0, 0, 0,,, 70, 7, 0, 90,, 0, 0, 0,,, 70, 7, 0, 90,, 0, 0, 0,,, 70, 7, 0, 90,, 0, 0, 0,,, 70, 7, 0, 90, / / / / 0/ 0/ / / 0/ 0/ / / 0/ 0/ / / /7 /7 / / / / 0/ 0/ / / 0/0 0/ Y/77 0Y/77 SA0CUL SA0CUL SA0RCUL SA0RCUL,, 7, 00,,, 7, 00,,, 7, 00,,, 7, 00, / / / / 0/ 0/ / / 0/ 0/ / / 0/ 0/ / / /7 /7 / / / / 0/ 0/ / / 0/0 0/ Y/77 0Y/ SA0CUL SA0CUL SA0RCUL SA0RCUL, 00,, 00, 00,, 00, 00,, 00, 00,, 00 / / / / / / / / / / / / / / / / / / / / / / / / 0/ 0/ 0/ 0/ 0/0 0/ SARCUL SA0RCUL 0, 0 700, 00 / / / / / / / / / / / / 0/ 0/ 0/0 0/0 0 0 E EACUL EACUL, 70, 7, 0, 90,, 70, 7, 0, 90, / / / / / / / / / / 7./ 7./ / / 0 0 0/9

14 Molded Case Circuit s Quick reference guide Line protection S series/, -pole IEC and CE marking conformed types Frame Pole Type Rated current (A) Rated insulation voltage [IEC 97-, JIS C0-] Rated breaking capacity (ka) [IEC 97-, JIS C0-] (Icu/Ics) * Rated operating voltage [UL] (V AC) Dimensions (mm) Page 0/ a b d c Page 0/ (V AC) (V DC) 0V AC 0V AC 0V AC V AC 00V AC 0V AC 0V AC V DC Page 0/ a b c d Mass (kg) Front mounting type Tripping device Front mounting, front connection No-mark Front mounting, rear connection X Flush mounting, rear connection E Flush mounting, top & bottom connection Y Plug-in mounting P IEC mm wide rail mounting Internal accessories Page 0/ Alarm switch K Alarm switch with terminal block KA Auxiliary switch W Auxiliary switch with terminal block WA Undervoltage trip R Shunt trip F Shunt trip with terminal block FA External accessories Motor operating mechanism M Handle padlocking device Cap type Q Plate type Q Mechanical interlocking device M M M Operating handle N-type N Operating handle V-type V Steel enclosure Direct operating C Dustproof steel enclosure Handle operating CV Rainproof steel enclosure Handle operating CW Terminal cover Short TS Terminal cover Long TB Insulation barrier Interphase * B Insulation barrier Earth BL Handle locking cover L Flat terminal S 0A SAC -CE,,,, 0, 0 *./././././ /./ 0. Hydraulic-magnetic BZKRC BZKRCA BZWRC BZWRCA BZR C BZF C BZF CA Notes: * Icu: Rated ultimate short-circuit breaking capacity Ics: Rated service short-circuit breaking capacity * Specify DC only when ordering circuit breakers for DC circuit. * Interphase insulation barriers are standard provided for the front mounting type breakers of AF and over. BZMC BZMC BZMC BZNC BZVC BZCC BZCVC BZCWC BZTSC BZTBC BZBC BZBLC BZLC BZSC SAC -CE 7 0. BZK C BZK CA BZW C BZW CA BZR C BZF C BZF CA BZMC BZMC BZMC BZNC BZVC BZCC BZCVC BZCWC BZTSC BZTBC BZBC BZBLC BZLC BZSC A SAC -CE,,, 0, 0, 0, *./ / 7./ 7./ 7./ 7./ / / 0 0. Hydraulic-magnetic BZKRC BZKRCA BZWRC BZWRCA BZR C BZF C BZF CA BZMC BZMC BZMC BZNC BZVC BZCC BZCVC BZCWC BZTSC BZTBC BZBC BZBLC BZLC BZSC SAC -CE 7 0. Available BZK C BZK CA BZW C BZW CA BZR C BZF C BZF CA BZMC BZMC BZMC BZNC BZVC BZCC BZCVC BZCWC BZTSC BZTBC BZBC BZBLC BZLC BZSC SARC -CE,, 0, 0, 0, * / 7./ / / / / / / 0 0. SARC -CE 7 0. Hydraulic-magnetic Not available BZKRC BZWRCA BZWRC BZWRCA BZR C BZF C BZF CA BZMC BZMC BZMC BZNC BZVC BZCC BZCVC BZCWC BZTSC BZTBC BZBC BZBLC BZLC BZSC BZK C BZK CA BZW C BZW CA BZR C BZF C BZF CA BZMC BZMC BZMC BZNC BZVC BZCC BZCVC BZCWC BZTSC BZTBC BZBC BZBLC BZLC BZSC Factory-mounted accessory 0/ Fuji Electric FA components & Systems Co., Ltd./D & C Catalog

15 Molded Case Circuit s Quick reference guide Line protection S series/, -pole IEC and CE marking conformed types Frame Pole Type Rated current (A) Rated insulation voltage [IEC 97-, JIS C0-] Rated breaking capacity (ka) [IEC 97-, JIS C0-] (Icu/Ics) * Rated operating voltage [UL] (V AC) Dimensions (mm) Page 0/ a b d c (V AC) (V DC) 0V AC 0V AC 0V AC V AC 00V AC 0V AC 0V AC V DC Page 0/ Mass (kg) Front mounting type Tripping device Front mounting, front connection No-mark Front mounting, rear connection X Flush mounting, rear connection E Flush mounting, top & bottom connection Y Plug-in mounting P IEC mm wide rail mounting Internal accessories Alarm switch Page 0/ K Alarm switch with terminal block KA Auxiliary switch W Auxiliary switch with terminal block WA Undervoltage trip R Shunt trip F Shunt trip with terminal block FA External accessories Motor operating mechanism M Handle padlocking device Cap type Q Plate type Q Mechanical interlocking device Page 0/ Operating handle N-type Operating handle V-type Steel enclosure Direct operating Dustproof steel enclosure Handle operating Rainproof steel enclosure Handle operating Terminal cover Short Terminal cover Long Insulation barrier Interphase * Insulation barrier Earth Handle locking cover Flat terminal a b c d M M M N V C CV CW TS TB B BL L S A SAC -CE *./ / 7./ 7./ 7./ 7./ / / 0 0. Hydraulic-magnetic BZKRC BZKRCA BZWRC BZWRCA BZR C BZF C BZF CA BZMC BZMC BZMC BZNC BZVC BZCC BZCVC BZCWC BZTSC BZTBC BZBC BZBLC BZLC BZSC Notes: * Icu: Rated ultimate short-circuit breaking capacity Ics: Rated service short-circuit breaking capacity * Specify DC only when ordering circuit breakers for DC circuit. * Interphase insulation barriers are standard provided for the front mounting type breakers of AF and over. SAC -CE 7 0. BZK C BZK CA BZW C BZW CA BZR C BZF C BZF CA BZMC BZMC BZMC BZNC BZVC BZCC BZCVC BZCWC BZTSC BZTBC BZBC BZBLC BZLC BZSC SARC -CE * / 7./ / / / / / / 0 0. Hydraulic-magnetic BZKRC BZKRCA BZWRC BZWRCA BZR C BZF C BZF CA BZMC BZMC BZMC BZNC BZVC BZCC BZCVC BZCWC BZTSC BZTBC BZBC BZBLC BZLC BZSC Available Not available SARC -CE 7 0. BZK C BZK CA BZW C BZW CA BZR C BZF C BZF CA BZMC BZMC BZMC BZNC BZVC BZCC BZCVC BZCWC BZTSC BZTBC BZBC BZBLC BZLC BZSC Factory-mounted accessory 0 Fuji Electric FA components & Systems Co., Ltd./D & C Catalog 0/

16 Molded Case Circuit s Quick reference guide Line protection S series/, -pole IEC and CE marking conformed types Frame Pole Type Rated current (A) Rated insulation voltage [IEC 97-, JIS C0-] Rated breaking capacity (ka) [IEC 97-, JIS C0-] (Icu/Ics) * Rated operating voltage [UL] (V AC) Dimensions (mm) Page 0/ a b d c (V AC) (V DC) 0V AC 0V AC 0V AC V AC 00V AC 0V AC 0V AC V DC Mass (kg) Front mounting type Tripping device Front mounting, front connection No-mark Front mounting, rear connection X Flush mounting, rear connection E Flush mounting, top & bottom connection Y Plug-in mounting P IEC mm wide rail mounting Internal accessories Page 0/ Alarm switch K Alarm switch with terminal block KA Auxiliary switch W Auxiliary switch with terminal block WA Undervoltage trip R Shunt trip F Shunt trip with terminal block FA External accessories Motor operating mechanism M Handle padlocking device Cap type Q Plate type Q Mechanical interlocking device Page 0/ Operating handle N-type Operating handle V-type Steel enclosure Direct operating Dustproof steel enclosure Handle operating Rainproof steel enclosure Handle operating Terminal cover Short Terminal cover Long Insulation barrier Interphase * Insulation barrier Earth Handle locking cover Flat terminal A SAC -CE, 0, 0, 0,,, 7, / /7 0/ 0/ 0/ / / Thermal-magnetic Notes: * Icu: Rated ultimate short-circuit breaking capacity Ics: Rated service short-circuit breaking capacity * Interphase insulation barriers are standard provided for the front mounting type breakers of AF and over. a b c d M M M N V C CV CW TS TB B BL L S BZK 0C BZK 0CA BZW 0C BZW 0CA BZF 0C BZF 0CA BZMC BZ-M0C- BZ-M0C- BZ-N0C BZV0C BZC0C BZ-CV0C BZ-CW0C BZ-TS0B- BZ-TB0B- BZ-B0B BZ-BL0B- BZL0C BZ-SB- SAC -CE BZK 0C BZK 0CA BZW 0C BZW 0CA BZF 0C BZF 0CA BZMC BZ-M0C- BZ-M0C- BZ-N0C BZV0C BZC0C BZ-CV0C BZ-CW0C BZ-TS0B- BZ-TB0B- BZ-B0B BZ-BLB BZL0C BZ-SB- SARC -CE, 0, 0, 0,,, 7, 0/ / / / / / 0/0 90. Thermal-magnetic BZK 0C BZK 0CA BZW 0C BZW 0CA BZF 0C BZF 0CA BZMC BZ-M0C- BZ-M0C- BZ-N0C BZV0C BZC0C BZ-CV0C BZ-CW0C BZ-TS0B- BZ-TB0B- BZ-B0B BZ-BLB BZL0C BZ-SB- SARC 90. -CE BZK 0C BZK 0CA BZW 0C BZW 0CA BZF 0C BZF 0CA BZMC BZ-M0C- BZ-M0C- BZ-N0C BZV0C BZC0C BZ-CV0C BZ-CW0C BZ-TS0B- BZ-TB0B- BZ-B0B BZ-BLB BZL0C BZ-SB- A SA0C -CE SA0C -CE,, 7, 00, / /7 0/ 0/ 0/ / /.. Thermal-magnetic Available Not available BZK 0C BZW 0CA BZW 0C BZW 0CA BZF 0C BZF 0CA BZM0C BZ-M0C BZ-M0C BZ-N0C BZV0C BZ-C0B BZ-CV0C BZ-CW0C BZ-TS0B BZ-TB0B BZ-B0B BZ-BL0B BZL0C BZ-SB- BZK 0C BZK 0CA BZW 0C BZW 0CA BZF 0C BZF 0CA BZM0C BZ-M0C BZ-M0C BZ-N0C BZV0C BZ-C0B BZ-CV0C BZ-CW0C BZ-TS0B BZ-TB0B BZ-B0B BZ-BL0B BZL0C BZ-SB- Factory-mounted accessory 0/ Fuji Electric FA components & Systems Co., Ltd./D & C Catalog

17 Molded Case Circuit s Quick reference guide Line protection S series/, -pole IEC and CE marking conformed types Frame Pole Type Rated current (A) Rated insulation voltage [IEC 97-, JIS C0-] Rated breaking capacity (ka) [IEC 97-, JIS C0-] (Icu/Ics) * Rated operating voltage [UL] (V AC) Dimensions (mm) Page 0/ a b d c (V AC) (V DC) 0V AC 0V AC 0V AC V AC 00V AC 0V AC 0V AC V DC a b c d A SA0RC -CE SA0RC -CE,, 7, 00, 0/ / / / / / 0/0. Thermal-magnetic Mass (kg) Front mounting type Tripping device Front mounting, front connection No-mark Front mounting, rear connection X Flush mounting, rear connection E Flush mounting, top & bottom connection Plug-in mounting Y P IEC mm wide rail mounting Internal accessories Page 0/ Alarm switch K BZK 0C Alarm switch with terminal block KA BZK 0CA Auxiliary switch W BZW 0C Auxiliary switch with terminal block WA BZW 0CA Undervoltage trip R Shunt trip F BZF 0C Shunt trip with terminal block FA BZF 0CA External accessories Motor operating mechanism Handle padlocking device Cap type Plate type Mechanical interlocking device Page 0/ Operating handle N-type Operating handle V-type Steel enclosure Direct operating Dustproof steel enclosure Handle operating Rainproof steel enclosure Handle operating Terminal cover Short Terminal cover Long Insulation barrier Interphase * Insulation barrier Earth Handle locking cover Flat terminal M Q Q M M M N V C CV CW TS TB B BL L S BZM0C BZ-M0C BZ-M0C BZ-N0C BZV0C BZ-C0B BZ-CV0C BZ-CW0C BZ-TS0B BZ-TB0B BZ-B0B BZ-BL0B BZL0C BZ-SB- Notes: * Icu: Rated ultimate short-circuit breaking capacity Ics: Rated service short-circuit breaking capacity * Interphase insulation barriers are standard provided for the front mounting type breakers of AF and over.. BZK 0C BZK 0CA BZW 0C BZW 0CA BZF 0C BZF 0CA BZM0C BZ-M0C BZ-M0C BZ-N0C BZV0C BZ-C0B BZ-CV0C BZ-CW0C BZ-TS0B BZ-TB0B BZ-B0B BZ-BL0B BZL0C BZ-SB- 00A SA0C -CE, 00,, 00 / / / / / / 0/ 0 7. Thermal-magnetic BZ-K70B BZ-K70BA BZ-W70B BZ-W70BA BZ-R70B- BZ-F70B- BZ-F70BA- BZ-MC BZ-MC BZ-MC BZ-NC BZVC BZ-CB BZ-CVC BZ-CWC BZ-TBB B-A BZ-L70B Available Not available SA0C -CE 0 7 BZ-K70B BZ-K70BA BZ-W70B BZ-W70BA BZ-R70B- BZ-F70B- BZ-F70BA- BZ-MC BZ-MC BZ-MC BZ-NC BZVC BZ-CB BZ-CVC BZ-CWC BZ-TBB B-A BZ-L70B Factory-mounted accessory 0 Fuji Electric FA components & Systems Co., Ltd./D & C Catalog 0/

18 Molded Case Circuit s Quick reference guide Line protection S series/, -pole IEC and CE marking conformed types Frame Pole Type Rated current (A) Rated insulation voltage [IEC 97-, JIS C0-] Rated breaking capacity (ka) [IEC 97-, JIS C0-] (Icu/Ics) * Rated operating voltage [UL] (V AC) Dimensions (mm) Page 0/ a b d c Page 0/ (V AC) (V DC) 0V AC 0V AC 0V AC V AC 00V AC 0V AC 0V AC V DC Mass (kg) Front mounting type Tripping device Front mounting, front connection No-mark Front mounting, rear connection X Flush mounting, rear connection E Flush mounting, top & bottom connection Y Plug-in mounting P IEC mm wide rail mounting Internal accessories Page 0/ Alarm switch K Alarm switch with terminal block KA Auxiliary switch W Auxiliary switch with terminal block WA Undervoltage trip R Shunt trip F Shunt trip with terminal block FA External accessories Motor operating mechanism M Handle padlocking device Cap type Q Plate type Q Mechanical interlocking device M M M Operating handle N-type N Operating handle V-type V Steel enclosure Direct operating C Dustproof steel enclosure Handle operating CV Rainproof steel enclosure Handle operating CW Terminal cover Short TS Terminal cover Long TB Insulation barrier Interphase * B Insulation barrier Earth BL Handle locking cover L Flat terminal S 00A SA0RC -CE, 00,, 00 0/ / / / / / / 0/ Thermal-magnetic Notes: * Icu: Rated ultimate short-circuit breaking capacity Ics: Rated service short-circuit breaking capacity * Interphase insulation barriers are standard provided for the front mounting type breakers of AF and over. a b c d BZ-K70B BZ-K70BA BZ-W70B BZ-W70BA BZ-R70B- BZ-F70B- BZ-F70BA- BZ-MC BZ-MC BZ-MC BZ-NC BZVC BZ-CB BZ-CVC BZ-CWC BZ-TBB B-A BZ-L70B SA0RC -CE 0 7 BZ-K70B BZ-K70BA BZ-W70B BZ-W70BA BZ-R70B- BZ-F70B- BZ-F70BA- BZ-MC BZ-MC BZ-MC BZ-NC BZVC BZ-CB BZ-CVC BZ-CWC BZ-TBB B-A BZ-L70B 0A SARC -CE 0, 0 0/ / / / / / / 0/0 7 9 Thermal-magnetic BZ-K70B BZ-K70BA BZ-W70B BZ-W70BA BZ-R70B- BZ-F70B- BZ-F70BA- BZ-M70C BZ-M70C BZ-M70C BZ-N70C BZV70C BZ-C70B BZ-CV70C BZ-TB70B B-A BZ-L70B Available Not available 00A SA0RC -CE 700, 00 0/ / / / / / / 0/0 7 Thermal-magnetic BZ-K70B BZ-K70BA BZ-W70B BZ-W70BA BZ-R70B- BZ-F70B- BZ-F70BA- BZ-M70C BZ-M70C BZ-M70C BZ-N70C BZV70C BZ-C70B BZ-CV70C BZ-TB70B B-A BZ-L70B Factory-mounted accessory 0/ Fuji Electric FA components & Systems Co., Ltd./D & C Catalog

19 Molded Case Circuit s Quick reference guide Line protection S series/, -pole IEC and CE marking conformed types Frame Pole Type Rated current(a) Rated insulation voltage(v) Rated breaking capacity (ka) Dimensions (mm) Protection function JIS C70 (sym) IEC 97- (Icu/Ics) BS 7 (sym)* Mass(kg) Front mounting, front connection Tripping device Trip button Mounting Front mounting, front connection Front mounting, rear connection Flush mounting, rear connection Plug-in mounting Internal accessories Auxiliary switch Alarm switch Shunt trip Undervoltage trip External accessories Motor operating mechanism Lead-wire terminal block a b d c AC DC V AC V AC 0V AC V DC V AC V AC 0V AC 0V AC 0V AC 00V AC 0V AC V DC a b c d (s) (A) (s) (ka) Long-time delay tripping time Short-time delay tripping current Short-time delay tripping time Instantaneous tripping current Ground fault current tripping or pre-alarm No marrk X E P W K F R M - 0A SAE SAE Adjustable /9 /9 /9 / /9 /9 / (at In) (Adjustable) In-In (Adjustable) (Adjustable).0- (Adjustable) Solid-state Provided Bar Stud Bar Stud A SAE SAE Adjustable /9 /9 /9 / /9 /9 / (Adjustable) Solid-state Provided Bar stud Bar stud A SAE SAE Adjustable / / / /9 / / / (Adjustable) 7 Solid-state Provided Bar stud Bar stud - Available Not available 0 Fuji Electric FA components & Systems Co., Ltd./D & C Catalog 0/

20 Molded Case Circuit s Quick reference guide Line protection S series/-pole Frame Pole Type Page 0/ Rated current (Amps) Ambient temp.: 0 C for general use Rated insulation voltage Ui (Volts) AC Rated JIS C70 sym V AC breaking V AC capacity 0V AC (ka) Dimensions a d a c (mm) b c Page 0/ d b Mass (kg) Front mounting type Tripping device Trip button Front mounting, front connection No-mark rear connection X Flush mounting, rear connection E top & bottom connection Y Plug-in mounting P Draw-out D Internal accessories Page 0/ Alarm switch K Auxiliary switch W Undervoltage trip R Shunt trip F External accessories Motor operating mechanism M Padlocking device Q Mechanical interlocking device M Operating handle N type N Operating handle V, G type V, G Steel enclosure C Steel enclosure with V type handle CV Terminal cover Short TS Terminal cover Long TB Insulation barrier Interphase B Insulation barrier Earth BL A SAB,,, 0 0, 0, Hydraulic-magnetic Provided BZ-KB BZ-WB BZ-FBT BZ-MC- BZ-N0C BZ-V0C BZ-TS0B- BZ-TB0B- A SAR, 0, 0, 0,, 7,.9 Thermal-magnetic Provided BZ-KB BZ-WB BZ-FBT BZ-MC- BZ-NB BZ-GC BZ-TBB- A SA0R,, 7 00, Thermal-magnetic Provided BZ-KB BZ-WB BZ-FBT BZ-MC- BZ-NB BZ-GC BZ-TBB- Notes: Handlelock cover is supplied on request (sold separately) Available Not available Factory-mounted accessory 0/ Fuji Electric FA components & Systems Co., Ltd./D & C Catalog

21 Molded Case Circuit s Quick reference guide Line protection S series/-pole Frame 00A 0A 00A Pole Type Page 0/ SA0HA SAH SA0H Rated current (Amps) Ambient temp.: 0 C for general use, 00, 00 0, 0 700, 00 Rated insulation voltage Ui (Volts) AC Rated JIS C70 sym V AC breaking V AC capacity 0V AC (ka) Dimensions (mm) Page 0/7 Mass (kg) Tripping devices a b d c a b c d Front mounting type 7 7. Thermal-magnetic Thermal-magnetic Thermal-magnetic Trip button Front mounting, front connection No-mark rear connection X Flush mounting, rear connection E top & bottom connection Y Plug-in mounting P Draw-out D Internal accessories Page 0/ Alarm switch K Auxiliary switch W Undervoltage trip R Shunt trip F Provided Provided Provided 0 External accessories Motor operating mechanism M Padlocking device Q Mechanical interlocking device M Operating handle N type N Operating handle G type G Steel enclosure C Steel enclosure with G type handle CG Terminal cover Inside panel use A Terminal cover Outside panel use T Insulation barrier Interphase B Insulation barrier Earth BL BZ-M N-A G-A B-A BZ-M N-A G-A B-A BZ-M N-A G-A B-A Notes: * Specify the frequency when ordering circuit breaker for AC circuit. Contact FUJI for DC circuit. Handlelock cover is supplied on request (sold separately) Available Not available Factory-mounted accessory Fuji Electric FA components & Systems Co., Ltd./D & C Catalog 0/7

22 Molded Case Circuit s Quick reference guide Line protection E series/, -pole IEC and CE marking conformed types Frame Pole Type Rated current (A) Rated insulation voltage [IEC 97-, JIS C0-] Rated breaking capacity (ka) [IEC 97-, JIS C0-] (Icu/Ics) * Rated operating voltage [UL] (V AC) Dimensions (mm) Page 0/ (V AC) (V DC) 0V AC 0V AC 0V AC V AC 00V AC 0V AC 0V AC V DC Mass (kg) Front mounting type Tripping device Front mounting, front connection No-mark Front mounting, rear connection X Flush mounting, rear connection E Flush mounting, top & bottom connection Y Plug-in mounting P IEC mm wide rail mounting Internal accessories Page 0/ Alarm switch K Alarm switch with terminal block KA Auxiliary switch W Auxiliary switch with terminal block WA Undervoltage trip R Shunt trip F Shunt trip with terminal block FA External accessories Motor operating mechanism M Handle padlocking device Cap type Q Plate type Q Mechanical interlocking device Operating handle N-type Operating handle V-type Steel enclosure Direct operating Dustproof steel enclosure Handle operating Rainproof steel enclosure Handle operating Terminal cover Short Terminal cover Long Insulation barrier Interphase * Insulation barrier Earth Handle locking cover Flat terminal a b d c Page 0/ Page 0/7 a b c d M M M N V C CV CW TS TB B BL L S 0A EAAC -CE,,,, 0, 0 0./././././ 0 0. EAAC -CE 7 0. Hydraulic-magnetic BZKRC BZKRCA BZWRC BZWRCA BZR C BZF C BZF CA BZMC BZMC BZMC BZNC BZVC BZCC BZCVC BZCWC BZTSC BZTBC BZBC BZBLC BZLC BZSC Notes: * Icu: Rated ultimate short-circuit breaking capacity Ics: Rated service short-circuit breaking capacity * Specify DC only when ordering circuit breakers for DC circuit. * Interphase insulation barriers are standard provided for the front mounting type breakers of AF and over. Except for EAAC BZK C BZK CA BZW C BZW CA BZR C BZF C BZF CA BZMC BZMC BZMC BZNC BZVC BZCC BZCVC BZCWC BZTSC BZTBC BZBC BZBLC BZLC BZSC A EAAC -CE EAAC -CE,,, 0, 0, 0, 0./././././ Hydraulic-magnetic BZKRC BZKRCA BZWRC BZWRCA BZR C BZF C BZF CA BZMC BZMC BZMC BZNC BZVC BZCC BZCVC BZCWC BZTSC BZTBC BZBC BZBLC BZLC BZSC BZK C BZK CA BZW C BZW CA BZR C BZF C BZF CA BZMC BZMC BZMC BZNC BZVC BZCC BZCVC BZCWC BZTSC BZTBC BZBC BZBLC BZLC BZSC EAC -CE EAC -CE,,, 0, 0, 0, *./././././ /./ Hydraulic-magnetic BZKRC BZKRCA BZWRC BZWRCA BZR C BZF C BZF CA Available Not available BZMC BZMC BZMC BZNC BZVC BZCC BZCVC BZCWC BZTSC BZTBC BZBC BZBLC BZLC BZSC BZK C BZK CA BZW C BZW CA BZR C BZF C BZF CA BZMC BZMC BZMC BZNC BZVC BZCC BZCVC BZCWC BZTSC BZTBC BZBC BZBLC BZLC BZSC Factory-mounted accessory 0/ Fuji Electric FA components & Systems Co., Ltd./D & C Catalog

23 Molded Case Circuit s Quick reference guide Line protection E series/, -pole IEC and CE marking conformed types Frame Pole Type Rated current (A) Rated insulation voltage [IEC 97-, JIS C0-] Rated breaking capacity (ka) [IEC 97-, JIS C0-] (Icu/Ics) * (V AC) (V DC) 0V AC 0V AC 0V AC V AC 00V AC 0V AC 0V AC V DC Rated operating voltage [UL] (V AC) Page 0/7 Dimensions (mm) a a d c b Page 0/ b c d Mass (kg) Front mounting type Tripping device Front mounting, front connection No-mark Front mounting, rear connection X Flush mounting, rear connection E Flush mounting, top & bottom connection Y Plug-in mounting P IEC mm wide rail mounting Internal accessories Page 0/ Alarm switch K Alarm switch with terminal block KA Auxiliary switch W Auxiliary switch with terminal block WA Undervoltage trip R Shunt trip F Shunt trip with terminal block FA External accessories Motor operating mechanism M Handle padlocking device Cap type Q Plate type Q Mechanical interlocking device Page 0/ Operating handle N-type Operating handle V-type Steel enclosure Direct operating Dustproof steel enclosure Handle operating Rainproof steel enclosure Handle operating Terminal cover Short Terminal cover Long Insulation barrier Interphase * Insulation barrier Earth Handle locking cover Flat terminal M M M N V C CV CW TS TB B BL L S A EAC -CE *././././ / /./ 0. Hydraulic-magnetic BZKRC BZKRCA BZWRC BZWRCA BZR C BZF C BZF CA BZMC BZMC BZMC BZNC BZVC BZCC BZCVC BZCWC BZTSC BZTBC BZBC BZBLC BZLC BZSC EAC -CE 7 0. Notes: * Icu: Rated ultimate short-circuit breaking capacity Ics: Rated service short-circuit breaking capacity * Specify DC only when ordering circuit breakers for DC circuit. * Interphase insulation barriers are standard provided for the front mounting type breakers of AF and over. Except for EAAC BZK C BZK CA BZW C BZW CA BZR C BZF C BZF CA BZMC BZMC BZMC BZNC BZVC BZCC BZCVC BZCWC BZTSC BZTBC BZBC BZBLC BZLC BZSC A EAAC -CE EAC -CE, 7,,, 7, 0 * / 7./ / /./ /./ / / / / Hydraulic-magnetic BZK C BZK CA BZW C BZW CA BZR C BZF C BZF CA BZMC BZMC BZMC BZNC BZVC BZCC BZCVC BZCWC BZTSC BZTBC BZBC BZBLC BZLC BZSC BZKRC BZKRCA BZWRC BZWRCA BZR C BZF C BZF CA BZMC BZMC BZMC BZNC BZVC BZCC BZCVC BZCWC BZTSC BZTBC BZBC BZBLC BZLC BZSC Available Not available EAC -CE 7 0. BZK C BZK CA BZW C BZW CA BZR C BZF C BZF CA BZMC BZMC BZMC BZNC BZVC BZCC BZCVC BZCWC BZTSC BZTBC BZBC BZBLC BZLC BZSC Factory-mounted accessory 0 Fuji Electric FA components & Systems Co., Ltd./D & C Catalog 0/9

24 Molded Case Circuit s Quick reference guide Line protection E series/, -pole IEC and CE marking conformed types Frame Pole Type Rated current (A) Rated insulation voltage [IEC 97-, JIS C0-] Rated breaking capacity (ka) [IEC 97-, JIS C0-] (Icu/Ics) * Rated operating voltage [UL] (V AC) Dimensions (mm) Page 0/ (V AC) (V DC) 0V AC 0V AC 0V AC V AC 00V AC 0V AC 0V AC V DC Mass (kg) Front mounting type Tripping device Front mounting, front connection No-mark Front mounting, rear connection X Flush mounting, rear connection E Flush mounting, top & bottom connection Y Plug-in mounting P IEC mm wide rail mounting Internal accessories Page 0/ Alarm switch K Alarm switch with terminal block KA Auxiliary switch W Auxiliary switch with terminal block WA Undervoltage trip R Shunt trip F Shunt trip with terminal block FA External accessories Motor operating mechanism M Handle padlocking device Cap type Q Plate type Q Mechanical interlocking device Operating handle N-type Operating handle V-type Steel enclosure Direct operating Dustproof steel enclosure Handle operating Rainproof steel enclosure Handle operating Terminal cover Short Terminal cover Long Insulation barrier Interphase * Insulation barrier Earth Handle locking cover Flat terminal a b d c Page 0/ a b c d M M M N V C CV CW TS TB B BL L S A EA0C -CE,, 7, 00, / / / / / / /. Thermal-magnetic BZK 0C BZK 0CA BZW 0C BZW 0CA BZF 0C BZF 0CA BZM0C BZ-M0C BZ-M0C BZ-N0C BZV0C BZ-C0B BZ-CV0C BZ-CW0C BZ-TS0B BZ-TB0B BZ-B0B BZ-BL0B BZL0C BZ-SB- Notes: * Icu: Rated ultimate short-circuit breaking capacity Ics: Rated service short-circuit breaking capacity * Interphase insulation barriers are standard provided for the front mounting type breakers. EA0C -CE. BZK 0C BZK 0CA BZW 0C BZW 0CA BZF 0C BZF 0CA BZM0C BZ-M0C BZ-M0C BZ-N0C BZV0C BZ-C0B BZ-CV0C BZ-CW0C BZ-TS0B BZ-TB0B BZ-B0B BZ-BL0B BZL0C BZ-SB- 00A EA0C -CE EA0C -CE, 00,, 00 /9 / / / / / 0/ Thermal-magnetic BZ-K70B BZ-K70BA BZ-W70B BZ-W70BA BZ-R70B- BZ-F70B- BZ-F70BA- BZ-MC BZ-MC BZ-MC BZ-NC BZVC BZ-CB BZ-CVC BZ-CWC BZ-TBB B-A BZ-L70B Available BZ-K70B BZ-K70BA BZ-W70B BZ-W70BA BZ-R70B- BZ-F70B- BZ-F70BA- BZ-MC BZ-MC BZ-MC BZ-NC BZVC BZ-CB BZ-CVC BZ-CWC BZ-TBB B-A BZ-L70B Not available 0A EAC -CE 0, 0 / / / / / / 0/ 7 9 Thermal-magnetic BZ-K70B BZ-K70BA BZ-W70B BZ-W70BA BZ-R70B- BZ-F70B- BZ-F70BA- BZ-M70C BZ-M70C BZ-M70C BZ-N70C BZV70C BZ-C70B BZ-CV70C BZ-TB70B B-A BZ-L70B Factory-mounted accessory 0/0 Fuji Electric FA components & Systems Co., Ltd./D & C Catalog

25 Molded Case Circuit s Quick reference guide Line protection E series/-pole IEC and CE marking conformed types E series/-pole Frame Pole Type Rated current (A) Rated insulation voltage [IEC 97-, JIS C0-] Rated breaking capacity (ka) [IEC 97-, JIS C 0-] (Icu/Ics) * Rated operating voltage [UL] (V AC) Dimensions (mm) Page 0/ (V AC) (V DC) 0V AC 0V AC 0V AC V AC 00V AC 0V AC 0V AC V DC a b c d 00A EA0C -CE 700, 00 / / / / / / 0/ 7 Thermal-magnetic Mass (kg) Front mounting type Tripping device Front mounting, front connection No-mark Front mounting, rear connection X Flush mounting, rear connection E Flush mounting, top & bottom connection Plug-in mounting Y P IEC mm wide rail mounting Internal accessories Page 0/ Alarm switch K BZ-K70B Alarm switch with terminal block KA BZ-K70BA Auxiliary switch W BZ-W70B Auxiliary switch with terminal block WA BZ-W70BA Undervoltage trip R BZ-R70B- Shunt trip F BZ-F70B- Shunt trip with terminal block FA BZ-F70BA- External accessories Motor operating mechanism Handle padlocking device Cap type Plate type Mechanical interlocking device Operating handle N-type Operating handle V-type Steel enclosure Direct operating Dustproof steel enclosure Handle operating Rainproof steel enclosure Handle operating Terminal cover Short Terminal cover Long Insulation barrier Interphase * Insulation barrier Earth Handle locking cover Flat terminal a b d c Page 0/ M Q Q M M M N V C CV CW TS TB B BL L S BZ-M70C BZ-M70C BZ-M70C BZ-N70C BZV70C BZ-C70B BZ-CV70C BZ-TB70B B-A BZ-L70B Notes: * Icu: Rated ultimate short-circuit breaking capacity Ics: Rated service short-circuit breaking capacity * Interphase insulation barriers are standard provided for the front mounting type breakers. Frame Pole Type Page 0/7 Rated current (Amps) Ambient temp.: 0 C for general use Rated insulation voltage Ui (Volts) AC DC Rated JIS C70 sym V AC breaking V AC capacity 0V AC (ka) V DC Dimensions a d a c (mm) b c Page 0/ d b Mass (kg) Front mounting type Tripping device Trip button Front mounting, front connection No-mark rear connection X Flush mounting, rear connection E top & bottom connection Y Plug-in mounting P Draw-out D Internal accessories Pege 0/ Alarm switch K Auxiliary switch W Undervoltage trip R Shunt trip F External accessories Motor operating mechanism M Padlocking device Q Mechanical interlocking device M Operating handle N type N Operating handle V type V Steel enclosure C Steel enclosure with V type handle CV Terminal cover Short TS Terminal cover Long TB Insulation barrier Interphase B Insulation barrier Earth BL A EAB,, 7, Hydraulic-magnetic Provided BZ-KB BZ-WB BZ-FBT BZ-MC- BZ-N0C BZ-V0C BZ-TS0B- BZ-TB0B- Available Not available Factory-mounted accessory 0 Fuji Electric FA components & Systems Co., Ltd./D & C Catalog 0/

26 Molded Case Circuit s Quick reference guide Line protection L series/-pole Frame Pole Type Page 0/ Rated current (Amps) Ambient temp.: 0 C for general use C for marine use Rated insulation voltage Ui (Volts) AC DC Rated JIS C70 sym V AC breaking 0V AC capacity 0V AC (ka) V DC IEC 97- [Icu/Ics] V AC V AC 0V AC 0V AC 0V AC 00V AC 0V AC V DC NK sym 0V AC V AC V DC A LAB, / / /0 / 7 Dimensions a d c a (mm) b Page 0/70 c d Mass (kg) Front mounting type. Tripping device Trip button Hydraulic-magnetic Provided Front mounting, front connection No-mark rear connection X Flush mounting, rear connection E top & bottom connection Y Plug-in mounting P Draw-out D Internal accessories Page 0/ Alarm switch K BZ-KB Auxiliary switch W BZ-WB Undervoltage trip R BZ-RBT Shunt trip F BZ-FBT External accessories Motor operating mechanism M Padlocking device Q Mechanical interlocking device M BZ-MC- Operating handle N type N BZ-N0C Operating handle V type V BZ-V0C Steel enclosure C Steel enclosure with V type handle CV Terminal cover Short TS Terminal cover Long TB Insulation barrier Interphase B BZ-B0B (Line), BB (Load) Insulation barrier Earth BL BZ-BL0B- b H series/, -pole A HBA HBA, 0, 0 0, 0 /7 /9 /7 /7 / 0/ 90.. Thermal-magnetic Provided BZ-KB BZ-WB BZ-RBT BZ-FBT BZ-MC- BZ-N0C BZ-V0C BZ-C0B- BZ-CV0C BZ-TS0B- BZ-TB0B- BZ-B0B BZ-BLB HBA HBA, 0, 0, 0,, 7, 0 /7 /9 /7 /7 / 0/ 90.. Thermal-magnetic Provided BZ-KB BZ-WB BZ-RBT BZ-FBT BZ-MC- BZ-N0C BZ-V0C BZ-C0B- BZ-CV0C BZ-TS0B- BZ-TB0B- BZ-B0B BZ-BLB A HR 0,, 7, Thermal-magnetic Provided BZ-KB BZ-WB BZ-RBT BZ-FBT BZ-M0C BZ-NC BZ-VC BZ-CB BZ-TSB BZ-TBB BZ-BB BZ-BLB Notes: Available Not available Factory-mounted accessory The breaking capacity for the 0V, 0V and V circuits are equivalent to that of 0V, 00V and 0V, resprctively. Interphase insulation barriers are standard provided for the front mounting type breakers. 0/ Fuji Electric FA components & Systems Co., Ltd./D & C Catalog

27 Molded Case Circuit s Quick reference guide Line protection H series/, -pole Frame A 00A Pole Type Page 0/ H0BA H0BA H0R H0B H0B H0R Rated current (Amps) Ambient temp.: 0 C for general use C for marine use,, 7 00,,, 7 00,, 00, 00, 00, 00 Rated insulation voltage Ui (Volts) AC DC Rated JIS C70 sym V AC breaking 0V AC capacity 0V AC (ka) V DC IEC 97 [Icu/Ics] V AC V AC 0V AC 0V AC 0V AC 00V AC 0V AC V DC /7 /9 /7 /7 / 0/ / / / / / 0/0 / / / / 0/0 NK sym 0V AC V AC V DC Dimensions (mm) Page 0/70 a b d c a b c d Mass (kg) Front mounting type.... Tripping device Thermal-magnetic Thermal-magnetic Trip button Provided Provided Front mounting, front connection rear connection No-mark X Flush mounting, rear connection top & bottom connection Plug-in mounting Draw-out E Y P D Internal accessories Page 0/ Alarm switch K Auxiliary switch W Undervoltage trip R Shunt trip F BZ-K0B BZ-W0B BZ-R0BT BZ-F0BT BZ-K0B BZ-W0B BZ-R0BT BZ-F0BT BZ-K70B BZ-W70B BZ-R70BT BZ-F70BT BZ-K70B BZ-W70B BZ-R70BT BZ-F70BT External accessories Motor operating mechanism M Padlocking device Q Mechanical interlocking device M Operating handle N type N Operating handle V type V BZ-M0C BZ-N0C BZ-V0C BZ-M0C BZ-NC BZ-VC BZ-MC BZ-NC BZ-VC BZ-MC BZ-NC BZ-VC Steel enclosure Steel enclosure with V type handle C CV BZ-C0B BZ-CB BZ-CB BZ-CVC BZ-CB BZ-CVB Terminal cover Short TS Terminal cover Long TB Insulation barrier Interphase B Insulation barrier Earth BL BZ-TS0B BZ-TB0B BZ-B0B BZ-BL0B BZ-TSB BZ-TBB BZ-BB BZ-BLB BZ-TBB B-A BZ-TBB B-A Available Not available Factory-mounted accessory Notes: The breaking capacity for the 0V, 0V and V circuits are equivalent to that of 0V, 00V and 0V, resprctively. Interphase insulation barriers are standard provided for the front mounting type breakers. Fuji Electric FA components & Systems Co., Ltd./D & C Catalog 0/

28 Molded Case Circuit s Quick reference guide Line protection H series/-pole Frame 0A 00A Pole Type Page 0/ HB HR H0B H0R Rated current (Amps) Ambient temp.: 0 C for general use C for marine use 0, 0 0, 0 700, , 00 Rated insulation voltage Ui (Volts) AC DC Rated JIS C70 sym V AC breaking 0V AC capacity 0V AC (ka) V DC IEC 97- [Icu/Ics] V AC V AC 0V AC 0V AC V AC 0V AC 0V AC V DC / / / / / 0/0 / / / / 0/0 / / / / / 0/0 / / / / 0/0 NK sym 0V AC V AC V DC Dimensions (mm) Page 0/7 a b d c a b c d Mass (kg) Tripping device Trip button Front mounting type 9 Thermal-magnetic Provided 9 Thermal-magnetic Provided Front mounting, front connection rear connection No-mark X Flush mounting, rear connection top & bottom connection Plug-in mounting Draw-out E Y P D Internal accessories Page 0/ Alarm switch K Auxiliary switch W Undervoltage trip R Shunt trip F BZ-K70B BZ-W70B BZ-R70BT BZ-F70BT BZ-K70B BZ-W70B BZ-R70BT BZ-F70BT BZ-K70B BZ-W70B BZ-R70BT BZ-F70BT BZ-K70B BZ-W70B BZ-R70BT BZ-F70BT External accessories Motor operating mechanism M Padlocking device Q Mechanical interlocking device M Operating handle N type N Operating handle V type V BZ-M70C BZ-N70C BZ-V70C BZ-M70C BZ-N70C BZ-V70C BZ-M70C BZ-N70C BZ-V70C BZ-M70C BZ-N70C BZ-V70C Steel enclosure Steel enclosure with V type handle C CV BZ-70B BZ-CV70C BZ-70B BZ-CV70C BZ-70B BZ-CV70C BZ-70B BZ-CV70C Terminal cover Short TS Terminal cover Long TB Insulation barrier Interphase B Insulation barrier Earth BL BZ-TB70B B-A BZ-TB70B B-A BZ-TB70B B-A BZ-TB70B B-A Notes: Interphase insulation barriers are standard provided for the front mounting type breakers. Available Not available Factory-mounted accessory 0/ Fuji Electric FA components & Systems Co., Ltd./D & C Catalog

29 Molded Case Circuit s Quick reference guide Motor protection Motor protection breakers Motors are normally controlled by MCCBs and magnetic starters. In this case the MCCB carries out overcurrent or short-circuit current protection while the starter deals with ON-OFF switching of the motor and offers protection against sustained overload currents. These are the motor breakers which combine the two functions. FUJI motor breakers are designed to eliminate erroneous operations due to the rush current produced at the time of starting the motor. They will trip in the face of sustained overcurrent when the integrated bimetal relay has operated. S series/, -pole IEC and CE marking conformed types Frame Pole Type Page 0/ Rated current (A) * Ambient temp.: 0 C for general use Rated insulation voltage [IEC 97-, JIS C0-] Rated breaking capacity (ka) [IEC 97-, JIS C0-] (Icu/Ics) * Rated operating voltage [UL] (V AC) Dimensions (mm) a d c Page 0/ (V AC) (V DC) 0V AC 0V AC V AC 00V AC 0V AC 0V AC Mass (kg) Front mounting type Tripping device Front mounting, front connection No-mark Front mounting, rear connection X Flush mounting, rear connection E Flush mounting, top & bottom connection Y Plug-in mounting P IEC mm wide rail mounting Internal accessories Page 0/ Alarm switch K Auxiliary switch W Undervoltage trip R Shunt trip F External accessories Handle padlocking device Cap type Q Plate type Q Mechanical interlocking device M M M Operating handle N-type N Operating handle V-type V Steel enclosure Direct operating C Dustproof steel enclosure Handle operating CV Rainproof steel enclosure Handle operating CW Terminal cover Short TS Terminal cover Long TB Insulation barrier Interphase * B Insulation barrier Earth BL Handle locking cover L Flat terminal S b a b c d 0A SACM -CE,,,,,./././././ / Hydraulic-magnetic BZKRC BZWRC BZRRC BZFRC BZMC BZMC BZMC BZNC BZVC BZCC BZCVC BZCWC BZTSC BZTBC BZBC BZBLC BZLC BZSC SACM -CE 0.7,.,,.,,,,,,, BZK C BZW C BZR C BZF C A SACM -CE 0.7,.,,.,,,,,,,, 0, 7./ 7./ 7./ 7./ 7./ / Hydraulic-magnetic SARCM -CE,,,,, 0, Notes: * For further information related to motor capacity, see page 0/9. Available Not available * Icu: Rated ultimate short-circuit breaking capacity Ics: Rated service short-circuit breaking capacity * Interphase insulation barriers are standard provided for the front mounting type breakers of AF and over. BZMC BZMC BZMC BZNC BZVC BZCC BZCVC BZCWC BZTSC BZTBC BZBC BZBLC BZLC BZSC BZK C BZW C BZR C BZF C 7./ / / / / / Hydraulic-magnetic Fuji Electric FA components & Systems Co., Ltd./D & C Catalog 0/ BZMC BZMC BZMC BZNC BZVC BZCC BZCVC BZCWC BZTSC BZTBC BZBC BZBLC BZLC BZSC BZK C BZW C BZR C BZF C BZMC BZMC BZMC BZNC BZVC BZCC BZCVC BZCWC BZTSC BZTBC BZBC BZBLC BZLC BZSC A SACM -CE / 7./ 7./ 7./ 7./ / Hydraulic-magnetic BZK C BZW C BZR C BZF C BZMC BZMC BZMC BZNC BZVC BZCC BZCVC BZCWC BZTSC BZTBC BZBC BZBLC BZLC BZSC Factory-mounted accessory 0

30 Molded Case Circuit s Quick reference guide Motor protection S series/, -pole IEC and CE marking conformed types Frame Pole Type Page 0/ Rated current (A) * Ambient temp.: 0 C for general use A SACM -CE,,, 0,,, 7, 90 SARCM -CE,,, 0,,, 7, 90 A SA0CM -CE,, 7, 00, SA0RCM -CE,, 7, 00, Rated insulation voltage [IEC 97-, JIS C0-] Rated breaking capacity (ka) [IEC 97-, JIS C0-] (Icu/Ics) * Rated operating voltage [UL] (V AC) Dimensions (mm) Page 0/ a (V AC) (V DC) 0V AC 0V AC V AC 00V AC 0V AC 0V AC Mass (kg) Front mounting type Tripping device Front mounting, front connection No-mark Front mounting, rear connection X Flush mounting, rear connection E Flush mounting, top & bottom connection Y Plug-in mounting P IEC mm wide rail mounting Internal accessories Alarm switch Page 0/ K Auxiliary switch W Undervoltage trip R Shunt trip F External accessories Handle padlocking device Cap type Q Plate type Q Mechanical interlocking device M M M Operating handle N-type N Operating handle V-type V Steel enclosure Direct operating C Dustproof steel enclosure Handle operating CV Rainproof steel enclosure Handle operating CW Terminal cover Short TS Terminal cover Long TB Insulation barrier Interphase * B Insulation barrier Earth BL Handle locking cover L Flat terminal S b d c a b c d / /7 0/ 0/ 0/ / 90. Thermal-magnetic BZK 0C BZW 0C BZF 0C Notes: * For further information related to motor capacity, see page 0/9. * Icu: Rated ultimate short-circuit breaking capacity Ics: Rated service short-circuit breaking capacity * Interphase insulation barriers are standard provided for the front mounting type breakers. BZMC- BZ-M0C- BZ-M0C- BZ-N0C BZV0C BZC0C BZ-CV0C BZ-CW0C BZ-TS0B- BZ-TB0B- BZ-B0B BZ-BLB BZL0C BZ-SB- 0/ / / / / / 90. Thermal-magnetic BZK 0C BZW 0C BZF 0C BZMC- BZ-M0C- BZ-M0C- BZ-N0C BZV0C BZC0C BZ-CV0C BZ-CW0C BZ-TS0B- BZ-TB0B- BZ-B0B BZ-BLB BZL0C BZ-SB- / /7 0/ 0/ 0/ /. Thermal-magnetic BZK 0C BZW 0C BZF 0C BZM0C BZ-M0C BZ-M0C BZ-N0C BZV0C BZ-C0B BZ-CV0C BZ-CW0C BZ-TS0B BZ-TB0B BZ-B0B BZ-BL0B BZL0C BZ-SB- Available Not available 0/ / / / / /. Thermal-magnetic BZK 0C BZW 0C BZF 0C BZM0C BZ-M0C BZ-M0C BZ-N0C BZV0C BZ-C0B BZ-CV0C BZ-CW0C BZ-TS0B BZ-TB0B BZ-B0B BZ-BL0B BZL0C BZ-SB- Factory-mounted accessory 0/ Fuji Electric FA components & Systems Co., Ltd./D & C Catalog

31 Molded Case Circuit s Quick reference guide Motor protection E series/-pole IEC and CE marking conformed types Frame Pole Type Page 0/ Rated current (A) * Ambient temp.: 0 C for general use 0A EAACM -CE.,.,,,,,, A EACM -CE,, 0, A EACM -CE A EACM -CE, 7, 90 A EA0CM -CE,, 7, 00, Rated insulation voltage [IEC 97-, JIS C0-] Rated breaking capacity (ka) [IEC 97-, JIS C0-] (Icu/Ics) * Rated operating voltage [UL] (V AC) Dimensions (mm) Page 0/ a (V AC) (V DC) 0V AC 0V AC V AC 00V AC 0V AC 0V AC Mass (kg) Front mounting type Tripping device Front mounting, front connection No-mark Front mounting, rear connection X Flush mounting, rear connection E Flush mounting, top & bottom connection Y Plug-in mounting P IEC mm wide rail mounting Internal accessories Alarm switch Page 0/ K Auxiliary switch W Undervoltage trip R Shunt trip F External accessories Handle padlocking device Cap type Q Plate type Q Mechanical interlocking device M M M Operating handle N-type N Operating handle V-type V Steel enclosure Direct operating C Dustproof steel enclosure Handle operating CV Rainproof steel enclosure Handle operating CW Terminal cover Short TS Terminal cover Long TB Insulation barrier Interphase * B Insulation barrier Earth BL Handle locking cover L Flat terminal S b d c a b c d 0./././././ Hydraulic-magnetic BZK C BZW C BZR C BZF C BZMC BZMC BZMC BZNC BZVC BZCC BZCVC BZCWC BZTSC BZTBC BZBC BZBLC BZLC BZSC Notes: * For further information related to motor capacity, see page 0/. * Icu: Rated ultimate short-circuit breaking capacity Ics: Rated service short-circuit breaking capacity * Interphase insulation barriers are standard provided for the front mounting type breakers of AF and over../././././ / Hydraulic-magnetic BZK C BZW C BZR C BZF C BZMC BZMC BZMC BZNC BZVC BZCC BZCVC BZCWC BZTSC BZTBC BZBC BZBLC BZLC BZSC././././ / / 7 0. Hydraulic-magnetic BZK C BZW C BZR C BZF C BZMC BZMC BZMC BZNC BZVC BZCC BZCVC BZCWC BZTSC BZTBC BZBC BZBLC BZLC BZSC Available 7./ / / / / / 7 0. Hydraulic-magnetic BZK C BZW C BZR C BZF C BZMC BZMC BZMC BZNC BZVC BZCC BZCVC BZCWC BZTSC BZTBC BZBC BZBLC BZLC BZSC Not available / / / / / /. Thermal-magnetic BZK 0C BZW 0C BZF 0C BZM0C BZ-M0C BZ-M0C BZ-N0C BZV0C BZ-C0B BZ-CV0C BZ-CW0C BZ-TS0B BZ-TB0B BZ-B0B BZ-BL0B BZL0C BZ-SB- Factory-mounted accessory 0 Fuji Electric FA components & Systems Co., Ltd./D & C Catalog 0/7

32 Molded Case Circuit s Quick reference guide Motor protection L and H series/-pole Frame Pole Type Page 0/ Rated current (Amps) * Ambient temp.: 0 C for general use C for marine use Rated insulation voltage Ui (Volts) AC DC Rated JIS C70 sym V AC breaking 0V AC capacity 0V AC (ka) IEC97-0V AC [Icu/Ics] 0V AC 0V AC 00V AC 0V AC Dimensions (mm) Page 0/70 NK sym 0V AC V AC a a b c d Mass (kg) Front mounting type Tripping device Trip button Front mounting, front connection No-mark rear connection X Flush mounting, rear connection E top & bottom connection Y Plug-in mounting P Draw-out D Internal accessories Page 0/ Alarm switch K Auxiliary switch W Undervoltage trip R Shunt trip F External accessories Motor operating mechanism M Padlocking device Q Mechanical interlocking device M Operating handle N type N Operating handle V type V Steel enclosure C Steel enclosure with V type handle CV Terminal cover Short TS Terminal cover Long TB Insulation barrier Interphase B Insulation barrier Earth BL b d c A LABM,,, / / /0 / 7. Hydraulic-magnetic Provided BZ-KB BZ-WB BZ-RBT BZ-FBT BZ-MC- BZ-N0C BZ-V0C BZ-B0B (LINE), BB (LOAD) BZ-BL0B- HBAM,,, 0, /9 / /7 /7 / 90. Thermal-magnetic BZ-KB BZ-WB BZ-RBT BZ-FBT BZ-MC- BZ-N0C BZ-V0C BZ-C0B- BZ-CV0C BZ-TS0B- BZ-TB0B- BZ-B0B BZ-BLB Notes: * For further information related to motor capacity, see page 0/. Available Not available Factory-mounted accessory 0/ Fuji Electric FA components & Systems Co., Ltd./D & C Catalog

33 Molded Case Circuit s Quick reference guide UL Listed S series/, -pole UL9 Listed Frame Pole Type Rated current (A) Rated insulation voltage [IEC 97-] Rated operating voltage [UL9] Rated breaking capacity (ka) Dimensions (mm) Page 0/7 UL9 (cul) IEC 97- (Icu/Ics) * JIS C0- a b d c Mass (kg) Front mounting type Tripping device Connecting terminal Screw Flat Block Internal accessories Alarm switch Alarm switch with terminal block Auxiliary switch Auxiliary switch with terminal block Undervoltage trip with terminal block Shunt trip Shunt trip with terminal block External accessories Handle padlocking device Cap type Operating handle N-type Operating handle V-type Terminal cover Short Terminal cover Long Terminal cover for flat terminal Insulation barrier Interphase * Handle locking cover Flat terminal Block terminal Page 0/ (V AC) (V AC) 0Y/77V AC 0V AC 0V AC 0V AC 0V AC V AC 00V AC 0V AC 0V AC V DC A SARCUL Notes: * Icu: Rated ultimate short-circuit breaking capacity Ics: Rated service short-circuit breaking capacity * Interphase insulation barriers are standard provided for the front mounting type breakers of AF and over. a b c d Page 0/ K KA W WA RA F FA Q N V TS TB TL B L S TA SARCUL,,,, 0, 0, 0, 0 / 7./ / / / / / Hydraulic-magnetic BZKRCU BZKRCAU BZWRCU BZWRCAU BZR CAU BZF CU BZF CAU BZNCP BZVC Provided BZTBCU BZLC BZ-SU0B BZK CU BZK CAU BZW CU BZW CAU BZR CAU BZF CU BZF CAU BZNCP BZVC Provided BZTBCU BZLC BZ-SU0B A SACUL, 0, 0, 0,,, 70, 7, 0, 90, 0 / /7 0/ 0/ 0/ / / Thermal-magnetic BZKR0CU BZKR0CAU BZWR0CU BZWR0CAU BZF 0CU BZF 0CAU BZN0CP BZV0C BZ-TS0B- BZ-TB0B- BZ-TL0B- BZB0CU BZL0C BZSUB BZTA Available SACUL BZK 0CU BZK 0CAU BZW 0CU BZW 0CAU BZF 0CU BZF 0CAU BZN0CP BZV0C BZ-TS0B- BZ-TB0B- BZ-TL0B- BZB0CU BZL0C BZSUB BZTA Not available SARCUL, 0, 0, 0,,, 70, 7, 0, 90, 0Y/77 0/ / / / / / 0/ Thermal-magnetic BZK 0CU BZK 0CAU BZW 0CU BZW 0CAU BZF 0CU BZF 0CAU BZN0CP BZV0C BZ-TS0B- BZ-TB0B- BZ-TL0B- BZB0CU BZL0C BZSUB BZTA SARCUL BZK 0CU BZK 0CAU BZW 0CU BZW 0CAU BZF 0CU BZF 0CAU BZN0CP BZV0C BZ-TS0B- BZ-TB0B- BZ-TL0B- BZB0CU BZL0C BZSUB BZTA Factory-mounted accessory 0 Fuji Electric FA components & Systems Co., Ltd./D & C Catalog 0/9

34 Molded Case Circuit s Quick reference guide UL Listed S series/, -pole Frame Pole Type Rated current (A) Rated insulation voltage [IEC 97-] Rated operating voltage [UL9] Rated breaking capacity (ka) Dimensions (mm) Page 0/7 UL9 (cul) IEC 97- (Icu/Ics) * JIS C0- UL9 Listed a b d c Page 0/ (V AC) (V AC) 0Y/77V AC 0V AC 0V AC 0V AC 0V AC V AC 00V AC 0V AC 0V AC V DC Mass (kg) Front mounting type Tripping device Connecting terminal Screw Flat Block Internal accessories See page 0/ Alarm switch K Alarm switch with terminal block KA Auxiliary switch W Auxiliary switch with terminal block WA Undervoltage trip with terminal block RA Shunt trip F Shunt trip with terminal block FA External accessories Handle padlocking device Cap type Q Operating handle N-type N Operating handle V-type V Terminal cover Short TS Terminal cover Long TB Terminal cover for flat terminal TL Insulation barrier Interphase * B Handle locking cover L Flat terminal S Block terminal TA A SA0CUL Notes: * Icu: Rated ultimate short-circuit breaking capacity Ics: Rated service short-circuit breaking capacity * Interphase insulation barriers are standard provided for the front mounting type breakers. a b c d,, 7, 00, 0 / /7 0/ 0/ 0/ / /. Thermal-magnetic BZK 0CU BZK 0CAU BZW 0CU BZW 0CAU BZF 0CU BZF 0CAU BZN0CP BZV0C BZ-TS0B BZ-TB0B BZ-TL0B BZB0CU BZL0C BZSUB BZTA SA0CUL. BZK 0CU BZK 0CAU BZW 0CU BZW 0CAU BZF 0CU BZF 0CAU BZN0CP BZV0C BZ-TS0B BZ-TB0B BZ-TL0B BZB0CU BZL0C BZSUB BZTA SA0RCUL SA0RCUL,, 7, 00, 0Y/77 0/ / / / / / 0/0. Thermal-magnetic BZK 0CU BZK 0CAU BZW 0CU BZW 0CAU BZF 0CU BZF 0CAU BZN0CP BZV0C BZ-TS0B BZ-TB0B BZ-TL0B BZB0CU BZL0C BZSUB BZTA Available Not available. BZK 0CU BZK 0CAU BZW 0CU BZW 0CAU BZF 0CU BZF 0CAU BZN0CP BZV0C BZ-TS0B BZ-TB0B BZ-TL0B BZB0CU BZL0C BZSUB BZTA Factory-mounted accessory 0/0 Fuji Electric FA components & Systems Co., Ltd./D & C Catalog

35 Molded Case Circuit s Quick reference guide UL Listed S series/, -pole UL9 Listed Frame Pole Type Page 0/ Rated current (A) Rated insulation voltage [IEC 97-] (V AC) Rated operating voltage [UL9] (V AC) Rated UL9 (cul) 0V breaking 0Y/77V capacity (ka) 0V IEC 97-0V AC (Icu/Ics) * 0V AC JIS C0-0V AC V AC 00V AC 0V AC 0V AC V DC Dimensions (mm) Page 0/7 a b d c Mass (kg) Front mounting type Tripping device Connecting terminal Screw Flat Block Internal accessories Alarm switch Alarm switch with terminal block Auxiliary switch Auxiliary switch with terminal block Undervoltage trip with terminal block Shunt trip Shunt trip with terminal block External accessories Handle padlocking device Cap type Operating handle N-type Operating handle V-type Terminal cover Short Terminal cover Long Terminal cover for flat terminal Insulation barrier Interphase * Handle locking cover Flat terminal Block terminal 00A SA0CUL, 00,, 00 0 / / / / / / 0/ 0 7. Thermal-magnetic Notes: * Icu: Rated ultimate short-circuit breaking capacity Ics: Rated service short-circuit breaking capacity * Interphase insulation barriers are standard provided for the front mounting type breakers. a b c d Page 0/ K KA W WA RA F FA Q N V TS TB TL B L S TA BZNCP BZVC BZ-TBB B-A BZ-L70B BZ-SUB Up to A: BZTA 00A: BZTA00 SA0CUL 0 7 BZNCP BZVC BZ-TBB B-A BZ-L70B BZ-SUB Up to A: BZTA 00A: BZTA00 SA0RCUL, 00,, / / / / / / / 0/ Thermal-magnetic BZNCP BZVC BZ-TBB B-A BZ-L70B BZ-SUB Up to A: BZTA 00A: BZTA00 Available Not available SA0RCUL 0 7 BZNCP BZVC BZ-TBB B-A BZ-L70B BZ-SUB Up to A: BZTA 00A: BZTA00 Factory-mounted accessory 0 Fuji Electric FA components & Systems Co., Ltd./D & C Catalog 0/

36 Molded Case Circuit s Quick reference guide UL Listed S series/-pole Frame Pole Type Rated current (A) Rated insulation voltage [IEC 97-] Rated operating voltage [UL9] Rated UL9 (cul) breaking capacity (ka) IEC 97- (Icu/Ics) * JIS C0- Dimensions (mm) Page 0/77 UL9 Listed a b d c Page 0/ (V AC) (V AC) 0V 0Y/77V 0V 0V AC 0V AC 0V AC V AC 00V AC 0V AC 0V AC V DC Mass (kg) Front mounting type Tripping device Connecting terminal Screw Flat Block Internal accessories Alarm switch See page 0/ K Alarm switch with terminal block KA Auxiliary switch W Auxiliary switch with terminal block WA Undervoltage trip with terminal block RA Shunt trip F Shunt trip with terminal block FA External accessories Handle padlocking device Cap type Q Operating handle N-type N Operating handle V-type V Terminal cover Short TS Terminal cover Long TB Terminal cover for flat terminal TL Insulation barrier Interphase * B Handle locking cover L Flat terminal S Block terminal TA Notes: * Icu: Rated ultimate short-circuit breaking capacity Ics: Rated service short-circuit breaking capacity * Interphase insulation barriers are standard provided for the front mounting type breakers. a b c d 0A SARCUL 0, 0 0 0/ / / / / / / 0/0 7 9 Thermal-magnetic BZN70CP BZV70C BZ-TB70B B-A BZ-L70B BZ-SU70B-0 BZ-TA0 00A SA0RCUL 700, 00 0 / / / / / / / 0/0 7 Thermal-magnetic BZN70CP BZV70C BZ-TB70B B-A BZ-L70B BZ-SU70B A: BZ-TA700 00A: BZ-TA00 Available Not available Factory-mounted accessory 0/ Fuji Electric FA components & Systems Co., Ltd./D & C Catalog

37 Molded Case Circuit s Quick reference guide UL Listed E series/, -pole UL9 Listed Frame Pole Type Rated current (A) Rated insulation voltage [IEC 97-] Rated operation voltage [UL9] Rated breaking capacity (ka) Dimensions (mm) Page 0/7 UL9 (cul) IEC 97- (Icu/Ics) * JIS C0- a d c Page 0/ (V AC) (V AC) 0Y/77V 0V 0V AC 0V AC 0V AC V AC 00V AC 0V AC 0V AC V DC a b c d Mass (kg) Front mounting type Tripping device Connecting terminal Screw Flat Block Internal accessories See page 0/ Alarm switch K Alarm switch with terminal block KA Auxiliary switch W Auxiliary switch with terminal block WA Undervoltage trip with terminal block RA Shunt trip F Shunt trip with terminal block FA External accessories Handle padlocking device Cap type Q Operating handle N-type N Operating handle V-type V Terminal cover Short TS Terminal cover Long TB Terminal cover for flat terminal TL Insulation barrier Interphase B Handle locking cover L Flat terminal S Block terminal TA Notes: * Icu: Rated ultimate short-circuit breaking capacity Ics: Rated service short-circuit breaking capacity b A EACUL, 70, 7, 0, 90, 0 / 7./ / / / / / 0. Hydraulic-magnetic BZKRCU BZKRCAU BZWRCU BZWRCAU BZR CAU BZF CU BZF CAU BZNCP BZVC Provided BZTBCU BZLC BZ-SU0B EACUL 7 0. BZK CU BZK CAU BZW CU BZW CAU BZR CAU BZF CU BZF CAU BZNCP BZVC Provided BZTBCU BZLC BZ-SU0B Available Not available Factory-mounted accessory 0 Fuji Electric FA components & Systems Co., Ltd./D & C Catalog 0/

38 Molded Case Circuit s UL Listed MCCB selection Circuit configuration and breaker application for control panels of industrial machinery in North America. ULA (Industrial control panels) requirements. The requirements of NFPA70 (NEC), NFPA79, and applicable UL standards must be satisfied.. Positioning of protective equipment Install branch circuit protection (BCP) for the main circuit at the point of electrical inlet. Use equipment that is UL listed as applicable to each kind of loads, installed under appropriate load conditions, as protective equipment for load circuits used in branch circuits downstream from the BCP. UL/Group Installation, which combines UL9 Listed SA/ EA-UL series and UL Listed Manual Motor Controllers (MMCs), complies with the ULA requirements for North American industrial control panels. Item NEC0. UL9 Listed SA/EA-UL series UL Listed Group Installation Includes an isolating function. Applicable to motor loads Applicable to other general use loads Applicable to resistance loads (heaters) Applicable to discharge lamp loads Applicable to incandescent lamp loads Application of UL9 Listed SA/EA-UL series and UL Listed MMCs (Group installation). For group installations, if the UL9 Listed SA/EA-UL series is installed at the power inlet point (upstream) and any of the following conditions is satisfied in the circuit, a UL Listed MMC can be used as a downstream multicircuit protective device. (In accordance with NEC0..) a. No conductor to the motor shall have an ampacity less than that of the branch-circuit conductors. b. No conductor to the motor shall have an ampacity less than one-third than of the branch-circuit conductors, the conductors to the motor overload device being not more than 7.m(ft) long and being protected from physical damage. c. Conductors from the branch-circuit short-circuit and ground-fault protective device to a listed manual motor controller shall be permitted to have an ampacity not less than / the rating or setting of the branch-circuit shortcircuit and ground-fault protective device. The conductors from the branch-circuit short-circuit and ground-fault protective device to the controller shall () be suitably protected from physical damage and enclosed either by an enclosed controller or by a raceway and shall be not more than m(ft) long or () shall have an ampacity not less than that of the branch circuit conductors.. The UL Listed MMC also has UL Group Installation certification.. See NEC 0. for detail.. Refer to the table on the next page for breaking capacity of the UL Listed Group Installation when making your selection. 0/

39 Molded Case Circuit s UL Listed MCCB selection Group Installation UL9 Listed MCCB or UL9 Listed MCCB + UL for upstream branch circuit protection (BCP) UL Listed MMC or UL Listed MMC + UL 0V AC for UL Listed MMC ( in figure) combined with UL9 Listed MCCB (+ UL) ( in figure) UL9 Listed MCCBs (+ UL) UL Listed MMCs SA0C SAC SARC SAC SARC EA0AC EAAC EAC EAC EAAC EAC SARCUL SGRCUL ka ka ka ka ka ka ka ka ka ka ka SACUL SARCUL SGCUL EACUL EGCUL ka ka ka ka ka ka ka ka ka ka ka SA0CUL SA0RCUL SG0CUL ka ka ka ka ka ka ka ka ka ka ka SA0CUL SA0RCUL ka ka ka ka ka ka ka ka ka ka ka SARCUL ka ka ka ka ka SA0RCUL ka ka ka ka ka 0 0V AC for UL Listed MMC ( in figure) combined with UL9 Listed MCCB (+ UL) ( in figure) UL9 Listed MCCBs (+ UL) UL Listed MMCs SA0C SAC SARC SAC SARC EAC EAC EAC SARCUL ka ka ka ka ka ka ka ka SA0RCUL ka ka ka ka ka ka ka ka SA0RCUL ka ka ka ka ka ka ka ka SARCUL ka ka ka ka SA0RCUL ka ka ka ka 0V AC for UL Listed MMC + UL ( in figure) combined with UL9 Listed MCCB (+ UL) ( in figure) UL9 Listed MCCBs (+ UL) UL Listed MMCs + UL SGC SGC SGRC SGC SGRC EGAC, EGAC EGC EGAC, EGAC EGC EGC EGAC, EGAC EGC SARCUL SGRCUL ka ka ka ka ka ka ka ka ka ka ka ka SACUL SARCUL SGCUL EACUL EGCUL ka ka ka ka ka ka ka ka ka ka ka ka SA0CUL SA0RCUL SG0CUL ka ka ka ka ka ka ka ka ka ka ka ka SA0CUL SA0RCUL ka ka ka ka ka ka ka ka ka ka ka ka SARCUL ka ka ka ka ka SA0RCUL ka ka ka ka ka 0/

40 Molded Case Circuit s MCCB selection UL Listed S series UL/cUL Listed (File No.E77) Frame Pole Type Rated operating voltage (V AC) Max. motor ratings Rated current (A) (HP) UL [cul]* -phase (-0) V AC 0-0V AC 0-0V AC -V AC Load (A) UL [cul] (-0) V AC 0-0V AC 0-0V AC -V AC Resistance * Discharge lamp * Incandescent lamp * Others * * * 0A SAC -CE / /. / SAC -CE / 0 7.,,,, 0, 0.,.,, 7.,,,,,, 0, 0,,,, 0, 0 0 A SAC -CE /. / / 0 7. SAC -CE ,,, 0, 0, 0,.,, 7.,., 0,,,, 0, 0, 0,,,, 0, 0, 0, SARC -CE 0. / / 0 7. SARC -CE 0,, 0, 0, 0,, 7.,., 0,,, 0, 0, 0,,, 0, 0, 0, Frame Pole Type Rated operating voltage (V AC) Max. motor ratings Rated current (A) (HP) -phase (-0) V AC UL [cul]* 0-0V AC 0-0V AC -V AC Load (A) UL [cul] Singlephase Singlephase (-0) V AC 0-0V AC 0-0V AC -V AC Resistance * Discharge lamp * Incandescent lamp * Others * * * A SAC -CE SAC -CE Notes: * The performance of UL approved models is indicated as applicable motor rating (HP). * Rated operating voltage -0V AC: For SAC, RC, C and RC. * Rated current x * Rated current x / SARC -CE SARC -CE / Fuji Electric FA components & Systems Co., Ltd./D & C Catalog

41 Molded Case Circuit s MCCB selection UL Listed E series UL/cUL Listed (File No.E77) Frame Pole Type Rated operating voltage (V AC) Max. motor ratings Rated current (A) (HP) UL [cul]* -phase (-0) V AC 0-0V AC 0-0V AC -V AC Load (A) UL [cul] Singlephase (-0) V AC 0-0V AC 0-0V AC -V AC Resistance * Discharge lamp * Incandescent lamp * Others * * * 0A EAAC -CE EAAC -CE / 0. / / / / / 0 /,,,, 0, 0.,.,, 7.,,,,,, 0, 0,,,, 0, 0 0 / A EAAC -CE 0 0. / 0. / / / / / 0 / EAAC -CE 0 / 0,,, 0, 0, 0,.,, 7.,,, 0,,,, 0, 0, 0,,,, 0, 0, 0, 7.. EAC -CE /. / / 0 7. EAC -CE Frame Pole Type Rated operating voltage (V AC) Max. motor ratings Rated current (A) (HP) -phase (-0) V AC UL [cul]* 0-0V AC 0-0V AC -V AC Load (A) UL [cul] Singlephase (-0) V AC 0-0V AC 0-0V AC -V AC Resistance * Discharge lamp * Incandescent lamp * Others * * * A EAC -CE 0 0 EAC -CE A EAAC -CE 0 7, 7, 0, 7.,, 7,, 7, EAC -CE ,, 7,, 0, 7.,,, 7,,, 7, EAC -CE Notes: * The performance of UL approved models is indicated as applicable motor rating (HP). * Rated operating voltage -0V AC: For SAC, RC, C and RC. * Rated current x * Rated current x / Fuji Electric FA components & Systems Co., Ltd./D & C Catalog 0/7

42 Molded Case Circuit s Mounting modifications Mounting modifications Standard type FUJI breakers are front mounting with front connections. The standard breaker can easily be modified to become front mounting rear connection type, flush mounting type and plug-in type. The additional parts such as insulation bases, barriers, covers and similar parts are added as required. Standard type Front mounting Front connection Mounting modification kits: See page 0/ BASIC DESIGN Additional main parts Front mounting Rear connection (X type) Additional main parts Flush mounting Rear connection (E type) Additional main parts Plug-in mounting (P type) Bar stud terminal SA0C SAC SARC SAC SARC EA0AC EAC EAAC EAC EAC EAAC Bar stud terminal SA0C SAC SARC SAC SARC EA0AC EAC EAAC EAC EAC EAAC Bar stud terminal SA0C SAC SARC SAC SARC EA0AC EAC EAAC EAC EAC EAAC Bar stud terminal SAC SARC SAC SARC SA00C SA00RC SA0RC SA00RC EAC EA00C EA0C EA00C Bar stud terminal SAC SARC SAC SARC SA00C SA00RC SA0RC SA00RC EAC EA00C EA0C EA00C Round stud terminal SAC SARC Each stud can be turned by 90 Each stud can be turned by 90 Additional main parts Decorative flush plate Flush mounting Top and bottom connection (Y type) SA0C SAC SARC SAC SARC EA0AC EAC EAAC EAC EAC EAAC Bar stud terminal SAC SARC SA00C SA00RC SA0RC SA00RC Each stud can be turned by 90 EAC EA00C EA0C EA00C 0/

43 Molded Case Circuit s Terminal connection Terminal connection/front mounting, front connection Front Flat terminal Front 0 Front Front Self lifting screw type SA0C SAC SARC EA0AC EAAC EAC Flat terminal Size Hexagonal head bolt type Size M SA00C EA00C M SA00RC Pan-head screw SAC SARC EAC EAAC EAC M SA0RC SA00RC EA0C EA00C M 0 Type of connection/up to AF Front mounting front connection or Direct connection Self lifting screw type Flat terminal Size Flat terminal connection Flat terminals are required. Pan-head screw SAC SARC M Flat terminal Hexagonal socket head bolt SAC SARC EAC M -hole type Flat bar studs/-hole type type Pole Type of flat terminal SA0C, SAC, SARC EA0AC, EAAC, EAC BZSC BZSC SAC, SARC EAC, EAC * SAC, SARC SAC, SARC EAC BZSC BZSC BZ-SB- BZ-SB- BZ-SB- BZ-SB- * EAC breaker of rated current A: BZSC or. 0/9

44 Molded Case Circuit s Wire size and terminal Wire size and crimp terminal The following is the size recommendations for crimp terminals. Crimp terminal R : JIS C0 CB : JEM-99 JST : Product of Japan Crimp Terminal Co., Ltd. F : FUJI special crimp terminal Ampere frame 0 EA0AC SA0C Wire size(mm ).0. R-.. R.-.. R-..7 R SAC, SARC EAAC, EAC LAB R- R.- R- R- HBA SAC, SARC EAC R- R- R.- R.- R- R- R- R- JST-S JST-S SAC, SARC HBA, HR EAAC EAC R- R- R.- R.- R- R- R- R- R- JST-S JST-S JST-S CB- F EAC SAC, SARC HBA, HR SA00C, SA00RC EA00C H00B, H00R SA0RC EA0C H0B, H0R R- R- R- R- R- R- CB- R- R- CB R- R- R00- R00- JST- JST SA00RC EA00C H00B, H00R SA0E SAE R- R- R- R- R00- R00- JST- JST- SAE R- R- R00- JST- Note: For solid-state trip types, same as the standard types. Block terminal connection (For UL Listed) MCCB type Rated current (A) SACUL SARCUL SACUL SARCUL 7 00 SA00CUL SA00RCUL SA0RCUL 0 0 SA00RCUL /0 Connectable wire size AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG /0AWG /0AWG /0AWG /0AWG kcmil kcmil 0kcmil /0AWG x -0kcmil x -0kcmil x -0kcmil x /0AWG-00kcmil x Notes: AWG is abbreviation of "American Wire Gauge" and the UL approved wire unit. The allowable temperature of wire is 7 C. (UL CSA approved) Tightening torque (N m). (. to.) ( to.). (. to ).9 (.9 to.).07 (.07 to.).07 (.07 to.) Type of screw head and size (mm) Slotted head screw Hexagonal socket head bolt.mm (/ inch) Hexagonal socket head bolt 9.mm (/ inch) Hexagonal socket head bolt mm (/ inch)

45 Molded Case Circuit s Wire size and terminal Crimp terminal connection (For UL Listed) MCCB type SARCUL EACUL SACUL SARCUL SACUL SARCUL Rated current (A) Applicable crimp terminal J.S.T. Mfg. Co., Ltd Aikoku Kogyo K.K. C wire R.- R- R- -S -S 7 C wire R- R.- R- R- -S -S R.- R- R- -S -S -S R- 70- CB0-S CB-S C wire R.- R- R- - -S 7 C wire R- R.- R- R- - -S R.- R- R- - -S -S R- R.- R- R- -S -S Notes: AWG is abbreviation of "American Wire Gauge" and the UL approved wire unit. The allowable temperature of wire is 7 C. (UL CSA approved) Nichifu Co., Ltd. Daido Solderless Terminal Mfg. Co., Ltd. C wire 7 C wire C wire 7 C wire R.- R- R- -S -S R-S R- R70- R.- R- R- -S -S R.- R- R- -S -S -S CB0-S CB-S Connectable wire size (AWG) C wire AWG AWG AWG AWG AWG AWG AWG 7 C wire AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG /0AWG /0AWG /0AWG /0AWG Tightening torque (N m) (.-.). (-) Type of screw head and size (mm) Cross-recessed pan-head screw M x Cross-recessed pan-head screw M x Cross-recessed pan-head screw M x Hexagonal socket head bolt M x 0 termination MCCB type Front connection Rear connection X Flush mounting E Y Plug-in mounting P SA0AC, SAC, SARC EA0AC, EAC, EAAC Self-lifiting terminal SAC, SARC EAC, EAC, EAAC SAC, SARC Flat terminal SAC, SARC EAC Flat terminal SA00C, SA00RC SA0RC, SA00RC EA00C, EA0C, EA00C Flat terminal 90 rotational stud 0/

46 Molded Case Circuit s Type number nomenclature Type number nomenclature IEC and CE marking conformed / Up to 00AF SA C M / X Q M - CE (CCC) Series SA: S series EA: E series Frame size : 0AF : AF : AF : AF 0: AF 0: 00AF : 0AF 0: 00AF No. of poles : -pole : -pole Operating characteristic Blank: Line protection M: Motor protection Instantaneous trip, non-automatic trip types and transformer primary circuit use are also available, contact FUJI. Standard CE: IEC and CE marking conformed (CCC): CCC approved Operation Blank: Manual operation With motor operating device M: V AC MN: V DC M: V AC MK: V DC M: 00V AC M: 0V AC Handle padlocking device O: Cap type Q: Plate type Mounting and connection Blank: Front mounting front connection X: Front mounting rear connection E: Flush mounting rear connection Y: Flush mounting top & bottom connection P: Plug-in mounting Rated current See page 0/ Ordering information Specify the following:. Type number of MCCB including factory-mounted optional accessories. Type number of customer-mountable optional accessories Customer-mountable optional accessories/sold separately Internal accessories Auxiliary switch, alarm switch, shunt trip device, undervoltage trip device (except for SA, SA, EA), terminal block Example S series... SA -pole, V, A Frame... C Rated current 7A... 7 Front moumting, front connection... Blank IEC and CE marking conformed... CE Complete type number SAC/7-CE External accessories Operating handles (N and V-type), terminal covers, insulation barrier, steel enclosures, handle locking covers, kits for mounting modification, flat terminal, mechanical interlock device Factory-mounted accessories External accessories Handle padlocking devices/q and Q, motor-operating mechanism/m, under voltage trip device for SA, SA and EA only Further information: See page 0/. 0/

47 Molded Case Circuit s Type number nomenclature Type number nomenclature Series SA: S series EA: E series F: F series H: H series L: L series Frame size : AF : AF 0: AF 0: 00AF : 0AF 0: 00AF : 0AF : AF : AF Number of poles : -pole : -pole : -pole : -pole Operating characteristics Blank: For line protection M: For motor protection SA B / E Q M W C Enclosure C: Steel enclosure CV: Steel enclosure with V handle Accessory W: With auxiliary switch K : With alarm switch F : With shunt tripping device R : With undervoltage tripping device (Provided terminal block) Operating device Blank: Manual operation M: Motor operating mechanism Handle padlocking device Q: Cap type Q: Plate type Mounting and connection Blank: Front mounting, front connection X: Front mounting, rear connection (to either metal or insulating panel) E: Flush mounting, rear connection Y: Flush mounting, top & bottom connection P: Plug-in mounting D: Draw-out Instantaneous trip and non-automatic types are also available, contact FUJI. Rated current See page 0/. 0 Ordering information Specify the following:. Type number. Optional accessories Lead wire or terminal block connection. When ordering MCCB with shunt tripping device, undervoltage tripping device or motor operating mechanism, specify rated voltage and frequency.. Handle type if required 0/

48 Molded Case Circuit s Type number nomenclature Type number nomenclature UL9 Listed SA CUL / 7 L Q W K F TB Series SA: S series EA: E series Frame size : AF : AF 0: AF 0: 00AF : 0AF 0: 00AF Number of poles : -pole : -pole Terminal cover Blank: Short TB: Long Tripping device F: Shunt trip R: Undervoltage trip Alarm switch K: Standard x SPDT K: Standard x SPDT KD: For low level circuit x SPDT KD: For low level circuit x SPDT Auxiliary switch W: Standard x SPDT W: Standard x SPDT WD: For low level circuit x SPDT WD: For low level circuit x SPDT Padlocking device Q: Cap type padlocking device Terminal combination See table below. Terminal combination Rated current See page 0/. Code Blank L L L L L L L7 L Terminal position Line Screw Block terminal Flat terminal Screw Flat terminal Screw Block terminal Flat terminal Block terminal Load Screw Block terminal Flat terminal Flat terminal Screw Block terminal Screw Block terminal Flat terminal Applicable breaker type SARCUL EACUL SACUL SARCUL SACUL SARCUL SA00CUL SA00RCUL SA0RCUL SA00RCUL/700 SA00RCUL/00 Available Not available 0/

49 Molded Case Circuit s Type number Line protection S series, -pole IEC and CE marking conformed S series, -pole IEC and CE marking conformed ampere frame Rated current (A) Type : Available mounting and connection ampere frame Rated current (A) Type : Available mounting and connection SAC/ -CE SAC/ -CE SAC/ -CE SAC/ -CE SAC/0 -CE SAC/0 -CE SAC/ -CE SAC/ -CE SAC/ -CE SAC/0 -CE SAC/0 -CE SAC/0 -CE SAC/ -CE SARC/ -CE SARC/ -CE SARC/0 -CE SARC/0 -CE SARC/0 -CE SARC/ -CE SAC/ -CE SARC/ -CE SAC/ -CE SAC/0 -CE SAC/0 -CE SAC/0 -CE SAC/ -CE SAC/ -CE SAC/7 -CE SAC/ -CE SARC/ -CE SARC/0 -CE SARC/0 -CE SARC/0 -CE SARC/ -CE SARC/ -CE SARC/7 -CE SARC/ -CE SA0C/ -CE SA0C/ -CE SA0C/7 -CE SA0C/00 -CE SA0C/ -CE SA0RC/ -CE SA0RC/ -CE SA0RC/7 -CE SA0RC/00 -CE SA0RC/ -CE SA0C/ -CE SA0C/00 -CE SA0C/ -CE SA0C/00 -CE SA0RC/ -CE SA0RC/00 -CE SA0RC/ -CE SA0RC/00 -CE Mounting Connection Front Front Blank Front Rear X Flush Rear E Flush Top and bottom Y Plug-in P Draw-out D Blank, X, E, Y, P Blank, X, E, Y, P Blank, X, E, Y, P Blank, X, E, Y, P Blank, X, E, Y, P Blank, X, E, P Blank, X, E, P Blank, X, E, P Blank, X, E, P Blank, X, E, P Blank, X, E, P SAC/ -CE SAC/ -CE SAC/ -CE SAC/ -CE SAC/0 -CE SAC/0 -CE SAC/ -CE SAC/ -CE SAC/ -CE SAC/0 -CE SAC/0 -CE SAC/0 -CE SAC/ -CE SARC/ -CE SARC/ -CE SARC/0 -CE SARC/0 -CE SARC/0 -CE SARC/ -CE SAC/ -CE SARC/ -CE SAC/ -CE SAC/0 -CE SAC/0 -CE SAC/0 -CE SAC/ -CE SAC/ -CE SAC/7 -CE SAC/ -CE SARC/ -CE SARC/0 -CE SARC/0 -CE SARC/0 -CE SARC/ -CE SARC/ -CE SARC/7 -CE SARC/ -CE SA0C/ -CE SA0C/ -CE SA0C/7 -CE SA0C/00 -CE SA0C/ -CE SA0RC/ -CE SA0RC/ -CE SA0RC/7 -CE SA0RC/00 -CE SA0RC/ -CE SA0C/ -CE SA0C/00 -CE SA0C/ -CE SA0C/00 -CE SA0RC/ -CE SA0RC/00 -CE SA0RC/ -CE SA0RC/00 -CE SARC/0 -CE SARC/0 -CE SA0RC/700 -CE SA0RC/00 -CE Blank, X, E, Y, P Blank, X, E, Y, P Blank, X, E, Y, P Blank, X, E, Y, P Blank, X, E, Y, P Blank, X, E, P Blank, X, E, P Blank, X, E, P Blank, X, E, P Blank, X, E, P Blank, X, E, P Blank, X, E, P, D Blank, X, E, P, D 0 0/

50 Molded Case Circuit s Type number Line protection S series, -pole E series, -pole IEC and CE marking conformed ampere frame Rated current (A) Type : Available mounting and connection ampere frame Rated current (A) Type : Available mounting and connection to 0 0 to 00 to SAB/ SAB/ SAB/ SAB/0 SAB/0 SAB/0 SAB/ SAR/ SAR/0 SAR/0 SAR/0 SAR/ SAR/ SAR/7 SAR/ SA0R/ SA0R/ SA0R/7 SA0R/00 SA0R/ SA0HA/ SA0HA/00 SA0HA/ SA0HA/00 SAH/0 SAH/0 SA0H/700 SA0H/00 SA/0E SA/E SAE/ Blank, X, E, Y Blank, X, E, Y Blank, X, E, Y Blank, X, E, Y Blank, X, E, Y Blank, X, E, Y Blank, X, E, Y Blank, X, E Blank, X, E Blank, X, E Blank, X, E Blank, X, E Blank, X, E Blank, X, E Blank, X, E Blank, X, E Blank, X, E Blank, X, E Blank, X, E Blank, X, E Blank, X, E Blank, X, E Blank, X, E Blank, X, E Blank, X, E Blank, X, E Blank, X, E Blank, X, E Blank, X, E Blank, X, E Blank, X, E EAAC/ -CE EAAC/ -CE EAAC/ -CE EAAC/ -CE EAAC/0 -CE EAAC/0 -CE EAAC/ -CE EAAC/ -CE EAAC/ -CE EAAC/0 -CE EAAC/0 -CE EAAC/0 -CE EAAC/ -CE EAC/ -CE EAC/ -CE EAC/ -CE EAC/0 -CE EAC/0 -CE EAC/0 -CE EAC/ -CE EAC/ -CE EAC/ -CE EAC/ -CE EAC/7 -CE EAC/ -CE EA0C/ -CE EA0C/ -CE EA0C/7 -CE EA0C/00 -CE EA0C/ -CE EA0C/ -CE EA0C/00 -CE EA0C/ -CE EA0C/00 -CE Blank, X, E, Y, P Blank, X, E, Y, P Blank, X, E, Y, P Blank, X, E, Y, P Blank, X, E, Y, P Blank, X, E, P Blank, X, E, P 0/

51 Molded Case Circuit s Type number Line protection E series, -pole IEC and CE marking conformed E series, -pole ampere frame Rated current (A) Type : Available mounting and connection ampere frame Rated current (A) Type : Available mounting and connection EAAC/ -CE EAAC/ -CE EAAC/ -CE EAAC/ -CE EAAC/0 -CE EAAC/0 -CE Blank, X, E, Y, P 7 EAB/ EAB/ EAB/7 EAB/ Blank, X, E, Y EAAC/ -CE EAAC/ -CE EAAC/ -CE EAAC/0 -CE EAAC/0 -CE EAAC/0 -CE EAAC/ -CE Blank, X, E, Y, P EAC/ -CE EAC/ -CE EAC/ -CE EAC/0 -CE EAC/0 -CE EAC/0 -CE EAC/ -CE Blank, X, E, Y, P EAC/ -CE Blank, X, E, Y, P 7 7 EAAC/-CE EAAC/7-CE EAAC/-CE EAC/ -CE EAC/ -CE EAC/7 -CE EAC/ -CE Blank, X, E, Y, P Blank, X, E, Y, P EA0C/ EA0C/ EA0C/7 EA0C/00 EA0C/ -CE -CE -CE -CE -CE Blank, X, E, P EA0C/ EA0C/00 EA0C/ EA0C/00 -CE -CE -CE -CE Blank, X, E, P EAC/0 EAC/0 -CE -CE Blank, X, E, P, D EA0C/700 EA0C/00 -CE -CE Blank, X, E, P, D 0/7

52 Molded Case Circuit s Type number Line protection H series, -pole L and H series, -pole ampere frame Rated current (A) Type : Available mounting and connection ampere frame Rated current (A) Type : Available mounting and connection HBA/ HBA/0 HBA/0 HBA/0 HBA/ HBA/ HBA/0 HBA/0 HBA/0 HBA/ HBA/ HBA/7 HBA/ H0BA/ H0BA/ H0BA/7 H0BA/00 H0BA/ H0B/ H0B/00 H0B/ H0B/00 Blank, X, E, P Blank, X, E, P Blank, X, E, P Blank, X, E, P LAB/ LAB/ HBA/ HBA/0 HBA/0 HBA/0 HBA/ HBA/ HBA/0 HBA/0 HBA/0 HBA/ HBA/ HBA/7 HBA/ HR/0 HR/ HR/ HR/7 HR/ H0BA/ H0BA/ H0BA/7 H0BA/00 H0BA/ Blank Blank, X, E, P Blank, X, E, P Blank, X, E, P Blank, X, E, P 7 00 H0R/ H0R/ H0R/7 H0R/00 H0R/ Blank, X, E, P H0B/ H0B/00 H0B/ H0B/00 Blank, X, E, P H0R/ H0R/00 H0R/ H0R/00 Blank, X, E, P HB/0 HB/0 Blank, X, E, P, D 0 0 HR/0 HR/0 Blank, X, E, P, D H0B/700 H0B/00 Blank, X, E, P, D H0R/700 H0R/00 Blank, X, E, P, D 0/

53 Molded Case Circuit s Type number Motor protection S series, -pole IEC and CE marking conformed ampere Motor capacity (kw) Rated current Type frame V 00V (A) SACM/ -CE SACM/ -CE SACM/ -CE SACM/ -CE SACM/ -CE SACM/ -CE :Available mounting and connection Blank, X, E, Y, P Blank, X, E, Y, P Blank, X, E, Y, P Blank, X, E, Y, P Blank, X, E, Y, P Blank, X, E, Y, P S series, -pole IEC and CE marking conformed ampere frame Motor capacity (kw) /0V /0V Rated current (A) Type : Available mounting and connection SACM/0.7 -CE SACM/. -CE SACM/ -CE SACM/. -CE SACM/ -CE SACM/ -CE SACM/ -CE SACM/ -CE SACM/ -CE SACM/ -CE SACM/ -CE SACM/ -CE SACM/0.7 -CE SACM/. -CE SACM/ -CE SACM/. -CE SACM/ -CE SACM/ -CE SACM/ -CE SACM/ -CE SACM/ -CE SACM/ -CE SACM/ -CE SACM/ -CE SACM/0 -CE SACM/ -CE SARCM/ -CE SARCM/ -CE SARCM/ -CE SARCM/ -CE SARCM/ -CE SARCM/0 -CE SARCM/ -CE SACM/ -CE SACM/ SACM/ SACM/ SACM/0 SACM/ SACM/ SACM/7 SACM/90 -CE -CE -CE -CE -CE -CE -CE -CE Blank, X, E, Y, P Blank, X, E, Y, P Blank, X, E, Y, P Blank, X, E, Y, P Blank, X, E, P 0 0/9

54 Molded Case Circuit s Type number Motor protection S series, -pole IEC and CE marking conformed ampere frame Motor capacity (kw) 00/ 00/ 0V 0V Rated current (A) Type SARCM/ -CE SARCM/ -CE SARCM/ -CE SARCM/0 -CE SARCM/ -CE SARCM/ -CE SARCM/7 -CE SARCM/90 -CE SA0CM/ -CE SA0CM/ -CE SA0CM/7 -CE SA0CM/00 -CE SA0CM/ -CE SA0RCM/ -CE SA0RCM/ -CE SA0RCM/7 -CE SA0RCM/00 -CE SA0RCM/ -CE : Available mounting and connection Blank, X, E, P Blank, X, E, P Blank, X, E, P E series, -pole IEC and CE marking conformed EAACM/. -CE EAACM/. -CE EAACM/ -CE EAACM/ -CE EAACM/ -CE EAACM/ -CE EAACM/ -CE EAACM/ -CE Blank, X, E, Y, P EACM/ EACM/ EACM/0 EACM/ -CE -CE -CE -CE Blank, X, E, Y, P 0 EACM/ -CE Blank, X, E, Y, P EACM/ EACM/7 EACM/90 -CE -CE -CE Blank, X, E, Y, P EA0CM/ EA0CM/ EA0CM/7 EA0CM/00 EA0CM/ -CE -CE -CE -CE -CE Blank, X, E, P L and H series, -pole LABM/ LABM/ LABM/ LABM/ Blank HBAM/ HBAM/ HBAM/ HBAM/0 HBAM/ Blank, X, E, P 0/

55 Molded Case Circuit s Type number UL Listed UL9 Listed S and E series, -pole S and E series, -pole ampere frame Rated current (A) Type : Available terminal combination ampere frame Rated current (A) Type : Available terminal combination SARCUL/ SARCUL/ SARCUL/ SARCUL/ SARCUL/0 SARCUL/0 SARCUL/0 SARCUL/ SACUL/ SACUL/0 SACUL/0 SACUL/0 SACUL/ SACUL/ SACUL/70 SACUL/7 SACUL/0 SACUL/90 SACUL/ SARCUL/ SARCUL/0 SARCUL/0 SARCUL/0 SARCUL/ SARCUL/ SARCUL/70 SARCUL/7 SARCUL/0 SARCUL/90 SARCUL/ SA0CUL/ SA0CUL/ SA0CUL/7 SA0CUL/00 SA0CUL/ SA0RCUL/ SA0RCUL/ SA0RCUL/7 SA0RCUL/00 SA0RCUL/ SA0CUL/ SA0CUL/00 SA0CUL/ SA0CUL/00 SA0RCUL/ SA0RCUL/00 SA0RCUL/ SA0RCUL/00 EACUL/ EACUL/70 EACUL/7 EACUL/0 EACUL/90 EACUL/ Blank, L, L, L Blank, L, L, L, L, L, L, L7, L Blank, L, L, L, L, L, L, L7, L Blank, L, L, L, L, L, L, L7, L Blank, L, L, L, L, L, L, L7, L L, L, L7, L L, L, L7, L Blank, L, L, L SARCUL/ SARCUL/ SARCUL/ SARCUL/ SARCUL/0 SARCUL/0 SARCUL/0 SARCUL/ SACUL/ SACUL/0 SACUL/0 SACUL/0 SACUL/ SACUL/ SACUL/70 SACUL/7 SACUL/0 SACUL/90 SACUL/ SARCUL/ SARCUL/0 SARCUL/0 SARCUL/0 SARCUL/ SARCUL/ SARCUL/70 SARCUL/7 SARCUL/0 SARCUL/90 SARCUL/ SA0CUL/ SA0CUL/ SA0CUL/7 SA0CUL/00 SA0CUL/ SA0RCUL/ SA0RCUL/ SA0RCUL/7 SA0RCUL/00 SA0RCUL/ SA0CUL/ SA0CUL/00 SA0CUL/ SA0CUL/00 SA0RCUL/ SA0RCUL/00 SA0RCUL/ SA0RCUL/00 SARCUL/0 SARCUL/0 SA0RCUL/700 SA0RCUL/00 EACUL/ EACUL/70 EACUL/7 EACUL/0 EACUL/90 EACUL/ Blank, L, L, L Blank, L, L, L, L, L, L, L7, L Blank, L, L, L, L, L, L, L7, L Blank, L, L, L, L, L, L, L7, L Blank, L, L, L, L, L, L, L7, L L, L, L7, L L, L, L7, L L, L, L7, L L, L, L7, L L Blank, L, L, L 0 0/

56 Molded Case Circuit s Dimensions S series/, -pole Dimensions, mm Front mounting, front connection SAC -CE, C -CE, RC -CE Insulation barrier Detachable. Panel drilling Front panel cutting Terminal section Mounting hole ø.9 Counter bore ø7. 0 ON M or ø R or less 7 7 M x or more 7. Trip button or more Max. ø. 7 Insulation barriers Standard provided: SAC, SARC Optional:SAC t SAC -CE, C -CE, RC -CE Insulation barrier Detachable. Panel drilling Front panel cutting Terminal section Mounting hole ø.9 Counter bore ø7. 0 ON M or ø R or less 7 7 M x or more 7 7 Trip button 7 or more Max. Insulation barriers Standard provided: SAC, SARC Optional: SAC 7 ø. t SAC -CE, RC -CE Insulation barrier Detachable. Panel drilling Front panel cutting Terminal section Mounting hole ø.9 Counter bore ø7. 0 ON M or ø R or less or more 7 7 M x or more ø9 7. Trip button Max. 7 t 0/

57 Molded Case Circuit s Dimensions S series/, -pole Dimensions, mm Front mounting, front connection SAC -CE, RC -CE. Insulation barrier Detachable Panel drilling Front panel cutting Terminal section Mounting hole ø.9 Counter bore ø7. M or ø R or less ON M x or more 7 or more ø9 7 7 Trip button Max. 7 t SAC -CE Panel drilling Front panel cutting Terminal section Mounting hole. Insulation barrier Detachable. 7 0 ø. 7 ø. M or ø R or less. M x 7 ON or more Trip button 0 or more Max. ø9 t SAC -CE Panel drilling Front panel cutting Terminal section Mounting hole. Insulation barrier Detachable. 7 ø. ø. M or ø. 7 ON 7 7 Trip button R or less or more M x or more Max. ø9 t 0/

58 7 Molded Case Circuit s Dimensions S series/, -pole Dimensions, mm Front mounting, front connection SARC -CE, RC -CE Mounting hole. Insulation barrier Detachable. Panel drilling Front panel cutting Terminal section ø. ø. M or ø R or less 7 ON 7 or more. M x 7 Trip button or more Note: -pole breaker is supplied in -pole frame with current carrying parts omitted from center pole. MAX.. ø9 t SA0C -CE, 0C -CE, 0RC -CE, 0RC -CE 0 Mounting hole Insulation barrier Detachable. Trip button ø. ON 70 7 ø. Panel drilling R or less M or ø or more Front panel cutting or more Terminal section. Max. Note: -pole breaker is supplied in -pole frame with current carrying parts omitted from center pole.. ø9 M x t SA0C -CE, 0C -CE, 0RC -CE, 0RC -CE 90 7 Insulation barrier Detachable Mounting hole ø. ON ø - Panel drilling Front panel cutting M or ø7 R or less 9 or more 0 0. Trip button Mx bolt or more Note: -pole breaker is supplied in -pole frame with current carrying parts omitted from center pole. 0/

59 Molded Case Circuit s Dimensions S series/, -pole Dimensions, mm Front mounting, front connection SARC -CE Insulation barrier Detachable Mounting hole 7 ø. 7. ø7 Panel drilling M or ø7 Front panel cutting ON 7 R or less 9 or more Trip button 9. Mx 0 bolt or more SA0RC -CE Insulation barrier Detachable Mounting hole 7 ø.. ø7 Panel drilling M or ø7 Front panel cutting ON 7 R or less 9 or more Trip button M x 0 bolt or more SAE, SAE, SAE, SAE Mounting hole 9 -pole 7 -pole N 70 0 Extension handle (Detachable) Panel drilling -pole -pole 0 M Mounting screw 70 ø /

60 Molded Case Circuit s Dimensions S series/, -pole Dimensions, mm Front mounting, front connection SAE, SAE 9. -pole 7 -pole N 70 Extension handle (Detachable) 0 0 Insulation panel Panel drilling -pole -pole ø M Mounting screw 70 ø9 SAB Insulation barrier Detachable. Panel drilling Front panel cutting Terminal section Mounting hole.7 ø ON 9 ø Handle M or ø Handle 7. to R or less 7 or more or more M ø. 70 Trip button 0 Max. 7 SAR Mounting hole Insulation barrier 7 Detachable 7.. ø. ø. ON M or ø Panel drilling R or less Front panel cutting Handle or more 7 Terminal section. M Trip button 0 7 or more Max.. ø9 0/

61 Molded Case Circuit s Dimensions S series/-pole Dimensions, mm Front mounting, front connection SA0R 0 Mounting hole Insulation barrier Detachable Trip button ø. 7 ø. M or ø Panel drilling Handle Front panel cutting Handle Terminal section.. ON R or less or more M x 0 0. or more ø9 Max. SA0HA 97 Handle... Mounting hole. 7 M Trip button bolt Panel drilling Front panel cutting ø. ø7 ON M or ø7 Handle Handle C L to R 99 0 SAH, 0H Mounting hole 97 Handle Extension handle ø..(.) 7() 7 ø7 Panel drilling Handle M or ø7 Front panel cutting Handle R M 0 bolt Trip button 7() (.) ( ): For SA0H 0/7

62 Molded Case Circuit s Dimensions S series/, -pole Dimensions, mm Front mounting, rear connection (type X) SAC -CE, C -CE, RC -CE Insulation base Terminal cover Panel M or ø Panel drilling ON 7 7. Trip button. 9 9 ø. M x bolt 9 ø SAC -CE, C -CE, RC -CE Insulation base Terminal cover Panel M or ø Panel drilling ON Trip button. 9 9 ø. M x bolt ø 0/

63 Molded Case Circuit s Dimensions S series/, -pole Dimensions, mm Front mounting, rear connection (type X) SAC -CE, RC -CE Panel drilling Insulation base Panel Terminal cover M or ø ON 7 7. Trip button. 9 9 ø. M x bolt 9 ø SAC -CE, RC -CE Panel drilling Terminal cover Panel Insulation base M or ø 0 9 ON Trip button. 9 9 ø. M x bolt ø SAC -CE Terminal cover 7 Panel Panel dilling Mounting hole ON Trip button 7 7 ø. ø M x bolt 0 0 M or ø Note: At shipment,studs are mounted on the MCCB unit as shown in the figure for side view. Studs for line side terminal : Mounted horizontally. Studs for load-side terminal : Mounted vertically. Each stud can be turned by 90. 0/9

64 Molded Case Circuit s Dimensions S series/, -pole Dimensions, mm Front mounting, rear connection (type X) SAC -CE Mounting hole Terminal cover 7 Panel Panel dilling Trip button ON ø. M x bolt 0 0 Note: At shipment, studs are mounted on the MCCB unit as shown in the figure for side view. Studs for line side terminal : Mounted horizontally. Studs for load-side terminal : Mounted vertically. Each stud can be turned by 90. ø 0 M or ø SARC -CE, RC -CE Mounting hole Terminal cover Trip button ON 7 Panel 7 7 Panel drilling 90 ø. M x bolt 0 0 Note: At shipment, studs are mounted on the MCCB unit as shown in the figure for side view. Studs for line side terminal : Mounted horizontally. Studs for load-side terminal : Mounted vertically. Each stud can be turned by 90. -pole breaker is supplied in -pole frame with current carrying parts omitted from center pole. ø 0 M or ø SA0C -CE, 0C -CE, 0RC -CE, 0RC -CE Mounting hole Terminal cover Trip button Max. 7 Panel ø9 M x bolt Panel drilling Note: At shipment, studs are mounted on the MCCB unit as shown in the figure for side view. Studs for line side terminal : Mounted horizontally. Studs for load-side terminal : Mounted vertically. Each stud can be turned by 90. -pole breaker is supplied in -pole frame with current carrying parts omitted from center pole. ø 70 M or ø 0/

65 Molded Case Circuit s Dimensions S series/, -pole Dimensions, mm Front mounting, rear connection (type X) SA0C -CE, 0C -CE, 0RC -CE, 0RC -CE Mounting hole. Panel Live section cover Panel drilling Angle mounting 90 7 ON Angle Mx bolt M or ø7 0. Trip button. 7. Insulation tube ø Angle Note: At shipment, studs are mounted on the MCCB unit as shown in the figure for side view. Studs for line side terminal : Mounted horizontally. Studs for load-side terminal : Mounted vertically. Each stud can be turned by 90. -pole breaker is supplied in -pole frame with current carrying parts omitted from center pole. ø7 SARC -CE Panel drilling Angle mounting 90 Mounting hole 7 97 ON Panel Angle Live section cover 0 Insulation barrier M or ø ø Angle 0x 0x 7 ø7 Trip button ø M x 0 bolt Note: At shipment, studs are mounted on the MCCB unit as shown in the figure for side view. Studs for line side terminal : Mounted horizontally. Studs for load side terminal : Mounted vertically. Each stud can be turned by 90. SA0RC -CE Panel drilling Angle mounting 90 Mounting hole 7 97 Trip button ON Panel Angle ø M x 0 bolt Live section cover Insulation barrier M or ø ø Angle 0x 0x 7 Note: At shipment, studs are mounted on the MCCB unit as shown in the figure for side view. Studs for line side terminal : Mounted horizontally. Studs for load side terminal : Mounted vertically. Each stud can be turned by 90. ø7 0/

66 Molded Case Circuit s Dimensions S series/ -pole Dimensions, mm Front mounting, rear connection (type X) SAE, SAE, SAE, SAE Panel drilling Panel cutting M Mounting screw Insulation plate -pole -pole -pole -pole ø9 -pole -pole Panel 0 ø Insulation tube for center pole ø R 9 of window Panel cutting dimensions include space of.mm to the handle window frame. SAE, SAE Mounting angle M Mounting screw -pole -pole -pole Panel drilling -pole ø9 Panel cutting -pole -pole 70 ø 0 0 Connecting length Insulation tube R 9 Panel cutting dimensions include space of.mm to the handle window frame. of window Dimensions for reference only. Confirm before construction begins. 0/

67 Molded Case Circuit s Dimensions E series/, -pole Dimensions, mm Front mounting, front connection EAAC -CE, AC -CE, C -CE Insulation barrier Detachable. Panel drilling Front panel cutting Terminal section Mounting hole ø.9 Counter bore ø7. 0 ON M or ø R or less 7 7 M x or more 7. Trip button or more Insulation barriers Standard provided: EAC Optional: EAAC, EAAC Max. ø. 7 t EAAC -CE, AC -CE, C -CE Insulation barrier Detachable. Panel drilling Front panel cutting Terminal section Mounting hole ø.9 Counter bore ø7. 0 ON M or ø 7 R or less 7 M x 0 or more 7 7 Trip button 7 or More Insulation barriers Standard provided: EAC Optional: EAAC, EAAC Max. ø. 7 t EAC -CE Insulation barrier Detachable. Panel drilling Front panel cutting Terminal section Mounting hole ø.9 Counter bore ø7. 0 ON M or ø R or less or more 7 7 M x or more ø9 7. Trip button Max. 7 t 0/

68 Molded Case Circuit s Dimensions E series/, -pole Dimensions, mm Front mounting, front connection EAC -CE. Insulation barrier Detachable Panel drilling Front panel cutting Terminal section Mounting hole ø.9 Counter bore ø7. M or ø R or less ON M x or more 7 or more ø9 7 7 Trip button Max. 7 t EAAC -CE, C -CE Insulation barrier Detachable. Panel drilling Front panel cutting Terminal section Mounting hole ø.9 Counter bore ø7. 0 ON R or less or more EAC -CE. 7 7 M or ø 7 M x 7 or more Max. 7 ø9 t 7 7 Trip button Insulation barriers Standard provided: EAC Optional: EAAC M x for EAC/ Insulation barrier Detachable Panel drilling Front panel cutting Terminal section Mounting hole ø.9 Counter bore ø7. 0 ON M or ø R or less or more 7 M x or more Max. 7 ø9 t 7. Trip button M x for EAC/ 0/

69 Molded Case Circuit s Dimensions E series/, -pole Dimensions, mm Front mounting, front connection EA0C -CE, 0C -CE 0 Mounting hole 70 Insulation barrier Detachable. EA0C -CE, 0C -CE 90 7 Trip button Insulation barrier Detachable Mounting hole ø. ON ø. ON 7 ø. Panel drilling Front panel cutting Terminal section ø - M or ø R or less or more or more. Max.. Note: -pole breaker is supplied in -pole frame with current carrying parts omitted from center pole. Panel drilling M or ø7 R or less 9 or more ø9 Front panel cutting M x t Trip button Mx bolt or more Note: -pole breaker is supplied in -pole frame with current carrying parts omitted from center pole. EAC -CE Insulation barrier Detachable Mounting hole 7 ø. 7. ø7 Panel drilling M or ø7 Front panel cutting ON 7 R or less 9 or more Trip button 9. Mx 0 bolt or more 0/

70 Molded Case Circuit s Dimensions E series/,, -pole Dimensions, mm Front mounting, front connection EA0C -CE Insulation barrier Detachable Mounting hole 7 ø.. ø7 Panel drilling M or ø7 Front panel cutting ON 7 R or less 9 or more Trip button M x 0 bolt or more EAB Insulation barrier Detachable. Panel drilling Front panel cutting Terminal section Mounting hole ø ø Handle M or ø Handle 7.7 ON 9 7. to R or less 7 or more or more 7.. M 70 Trip button 0 Max. 7 ø9 t Front mounting, rear connection (type X) EAAC -CE, AC -CE, C -CE Panel Insulation base Terminal cover M or ø Panel drilling ON 7 7. Trip button. 9 9 ø. M x bolt 9 ø 0/

71 Molded Case Circuit s Dimensions E series/, -pole Dimensions, mm Front mounting, rear connection (type X) EAAC -CE, AC -CE, C -CE Panel drilling Terminal cover Panel Insulation base M or ø ON EAC -CE Panel drilling Insulation base Panel Terminal cover M or ø 0 ON 7 7. Trip button. 9 9 ø. M x bolt 9 ø EAC -CE Panel drilling Terminal cover Panel Insulation base M or ø 9 ON 7 9 Trip button. 9 9 ø. M x bolt ø 7 7 Trip button. 9 9 ø. M x bolt ø 0/7

72 Molded Case Circuit s Dimensions E series/, -pole Dimensions, mm Front mounting, rear connection (type X) EAC -CE Terminal cover Insulation base Panel M or ø Panel drilling ON 7 7. Trip button. 9 9 ø. M x bolt 9 ø EAAC -CE, C -CE Terminal cover Insulation base Panel M or ø Panel drilling 9 ON Trip button. 9 9 ø. M x bolt ø EA0C -CE, 0C -CE Mounting hole Terminal cover Trip button 7 Panel Max. ø9 M x bolt Panel drilling Note: At shipment, studs are mounted on the MCCB unit as shown in the figure for side view. Studs for line side terminal : Mounted horizontally. Studs for load side terminal : Mounted vertically. Each stud can be turned by 90. -pole breaker is supplied in -pole frame with current carrying parts omitted from center pole. ø 70 M or ø 0/

73 Molded Case Circuit s Dimensions E series/, -pole Dimensions, mm Front mounting, rear connection (type X) EA0C -CE, 0C -CE Mounting hole. Panel Live section cover Panel drilling Angle mounting 90 7 ON Angle M x bolt M or ø7 0. Trip button. 7. Insulation tube ø Angle Note: At shipment, studs are mounted on the MCCB unit as shown in the figure for side view. Studs for line side terminal : Mounted horizontally. Studs for load side terminal : Mounted vertically. Each stud can be turned by 90. -pole breaker is supplied in -pole frame with current carrying parts omitted from center pole. ø7 EAC -CE Panel drilling Angle mounting 90 Mounting hole 7 97 ON Panel Angle Live section cover 0 Insulation barrier M or ø ø Angle 0x 0x 7 ø7 Trip button ø M x 0 bolt Note: At shipment, studs are mounted on the MCCB unit as shown in the figure for side view. Studs for line side terminal : Mounted horizontally. Studs for load side terminal : Mounted vertically. Each stud can be turned by 90. EA0C -CE Panel drilling Angle mounting 90 Mounting hole 7 97 Trip button ON Panel Angle ø M x 0 bolt Live section cover Insulation barrier M or ø ø Angle 0x 0x 7 Note: At shipment, studs are mounted on the MCCB unit as shown in the figure for side view. Studs for line side terminal : Mounted horizontally. Studs for load side terminal : Mounted vertically. Each stud can be turned by 90. ø7 0/9

74 Molded Case Circuit s Dimensions L, H series/, -pole Dimensions, mm Front mounting, front connection LAB Mounting hole Insulation barrier Detachable ø ø Panel drilling Front panel cutting Line : 7 Load : Terminal section 7.. of handle.7 ON M or ø to R or less or more Line : Load : M Trip button Live section cover 7 or more ø. t Max.. HBA, HBA, HBA, HBA Mounting hole.. 7 Insulation barrier Detachable ON ø.. ø. Panel drilling Front panel cutting Terminal section M or ø R or less or more Max... ø9 M 7 t 90 Trip button 0 7 or more Note: -pole breaker is supplied in -pole frame with current carrying parts omitted from center pole. H0BA, H0BA 0 Insulation barrier Detachable Mounting hole. ø. ø. 7 ON Panel drilling M or ø R or less or more Font panel cutting Terminal section Hexagonal head bolt M 0 Max... ø9 t 70 Trip button. or more Note: -pole breaker is supplied in -pole frame with current carrying parts omitted from center pole. 0/70

75 Molded Case Circuit s Dimensions H series/, -pole Dimensions, mm Front mounting, front connection HR, H0R Insulation barrier Detachable 90. Panel drilling Front panel cutting Terminal section Mounting hole Trip button ø. ON 9. ø. M or ø R or less or more or more.. ø9 T M 0 Hexagonal head bolt Max.. 99 Note: -pole breaker is supplied in -pole frame with current carrying parts omitted from center pole. H0B, H0B, H0R 90 7 * 0 Mounting hole *. Insulation barrier Detachable 0. 7 Trip button M bolt * for H0R * for H0R ø. ON ø to Panel drilling M or ø7 R or less 9 or more Front panel cutting 7 or more Note: -pole breaker is supplied in -pole frame with current carrying parts omitted from center pole. 0 HB, HR Insulation barrier Detachable Mounting hole 7. Panel drilling Front panel cutting 70 ø. ø7 M or ø Trip button M 0 bolt ON R or less 9 or more 07 or more Fuji Electric FA Components & Co., Ltd./D & C Catalog 0/7

76 Molded Case Circuit s Dimensions H series/, -pole Dimensions, mm Front mounting, front connection H0B, H0R Insulation barrier Detachable Mounting hole. Panel drilling Front panel cutting 70 ø. ø7 M or ø Trip button M 0 bolt ON R or less 9 or more 07 or more Front mounting, rear connection (type X) HBA, HBA, HBA, HBA Panel cutting Mounting hole Terminal cover Panel 7 ON ø. M bolt ø 0 M or ø 90 Trip button Note: -pole breaker is supplied in -pole frame with current carrying parts omitted from center pole. At shipment, studs are mounted on the MCCB unit as shown in the figure for side view. Studs for line side terminals : mounted horizontally Studs for load side terminals : mounted vertically Each stud can be mounted both horizontally or vertically. H0BA, H0BA Mounting hole Terminal cover Panel 7 Panel cutting ON Trip button Max.. ø9 M bolt ø 70 M or ø Note: -pole breaker is supplied in -pole frame with current carrying parts omitted from center pole. At shipment, studs are mounted on the MCCB unit as shown in the figure for side view. Studs for line side terminals : mounted horizontally Studs for load side terminals : mounted vertically Each stud can be mounted both horizontally or vertically. 0/7

77 Molded Case Circuit s Dimensions H series/, -pole Dimensions, mm Front mounting, rear connection (type X) HR, H0R Mounting hole Terminal cover Panel 7 Panel cutting ON Trip button 9. Max. 99. ø9 M bolt ø 70 M or ø Note: -pole breaker is supplied in -pole frame with current carrying parts omitted from center pole. At shipment, studs are mounted on the MCCB unit as shown in the figure for side view. Studs for line side terminals : mounted horizontally Studs for load side terminals : mounted vertically Each stud can be mounted both horizontally or vertically. H0B, H0B, H0R 90 Mounting hole ON Panel cutting Angle ø M bolt Trip button. Panel 7. Insulation tube Live section cover ø M or ø7 Angle mounting Note: -pole breaker is supplied in -pole frame with current carrying parts omitted from center pole. At shipment, studs are mounted on the MCCB unit as shown in the figure for side view. Studs for line-side terminals : mounted horizontally Studs for load-side terminals : mounted vertically Each stud can be mounted both horizontally or vertically. Angle 0 0 ø7 0 HB, HR Mounting hole Panel Live section cover Panel cutting Angle mounting ON Trip button.. Angle ø M 0 bolt Insulation barrier M or ø Angle ø Note: -pole breaker is supplied in -pole frame with current carrying parts omitted from center pole. At shipment, studs are mounted on the MCCB unit as shown in the figure for side view. Studs for line side terminals : mounted horizontally Studs for load side terminals : mounted vertically Each stud can be mounted both horizontally or vertically. ø7 Fuji Electric FA Components & Co., Ltd./D & C Catalog 0/7

78 Molded Case Circuit s Dimensions H series/ -pole Dimensions, mm Front mounting, rear connection (type X) H0B, H0R Mounting hole Panel Live section cover Panel cutting Angle mounting ON Trip button. Angle ø M 0 bolt Insulation barrier M or ø Angle ø Note: -pole breaker is supplied in -pole frame with current carrying parts omitted from center pole. At shipment, studs are mounted on the MCCB unit as shown in the figure for side view. Studs for line side terminals : mounted horizontally Studs for load side terminals : mounted vertically Each stud can be mounted both horizontally or vertically. ø7 Dimensions for reference only. Confirm before construction begins. 0/7

79 Molded Case Circuit s Dimensions UL Listed Dimensions, inch [mm] Front mounting, front connection SARCUL Terminal cover Short type LC. [].7 [0] LC.99 [] Mounting hole 0.9 [] 0.9 [].99 [] Trip button.07 [] 0. [9.].97 [] 0. [9.].00 [].9 [] ON.909 [.].00 []. [] 0.09 [.] Panel drilling 0.- tap or 0.97 dia. [M or ø].07 [] Terminal section 0.9 [7] 0. [] 0.7 [.] M x 0.9 [] 0.7 [] 0. [].07 [] SARCUL.7 [0] LC Mounting hole. [] L C.99 [].9 [7] Terminal cover Short type.99 [].07 [] 0. [9.].97 [] 0. [9.] Trip button.00 [].9 [] ON.909 [.] LC.00 []. [] 0.09 [.] LC Panel drilling 0.- tap or 0.97 dia. [M or ø] LC 0.9 [].07 [] Terminal section 0.9 [7] 0. [] 0.7 [.] 0.9 [] M x [] 0. [].07 [] SACUL, SACUL, SARCUL, SARCUL Mounting hole 0.[].99[].[].[.] Insulation barrier.99[].0[].[].[] 0. dia [ø.] ON LC.0[].[] 0.09[.].[7] 0.77 dia [ø.] Panel drilling Front panel cutting Terminal section 0.- tap or 0.97 dia. [M or ø] LC.97[] R0.07 [R] or less LC LC.07 [] or more 0.9 [7] 0.9 [] 0. [.] M x Trip button.[0]. [7] or more 0.9 [].[].[90] 0.079[].[] 0.[].[] Note: -pole breaker is supplied in -pole frame with current carrying parts omitted from center pole. Fuji Electric FA Components & Co., Ltd./D & C Catalog 0/7

80 .00 [.] Molded Case Circuit s Dimensions UL Listed Dimensions, inch [mm] Front mounting, front connection SA0CUL, SA0CUL. [0].9 [].9 [].0 [] LC LC Insulation barrier Mounting hole 0. [].99 [] Trip button 0.Dia. [ø.] Panel drilling Front panel cutting Terminal section.0 [.] 0.09 []. [7] ON [] [.] LC M x 0.77Dia. [ø.] 0.- Tap or 0.97 dia. [M or ø] LC LC.9 [] R0.07 [R] or less.07 [] or more.00 [.].0 [].0 [].0 [] or more 0.9 [].7 [70].97 []. [] []. [] 0. [].07 [] Note: -pole breaker is supplied in -pole frame with current carrying parts omitted from center pole. SA0RCUL, SA0RCUL. [90].9 [].9 [].0 [] LC LC Insulation barrier Mounting hole 0. [].99 [] Trip button 0.Dia. [ø.] ON LC.0 [.] 0.09 []. [7].0 [] 0.77Dia. [ø.] LC Panel drilling Front panel cutting Terminal section 0.- Tap or 0.97 dia. [M or ø] LC.9 [] R0.07 [R] or less LC.07 [] or more 0. [.] 0. [] M x.7 [70].97 []. [] []. [] 0. [].07 [].0 [].0 [] or more 0.9 [] Note: -pole breaker is supplied in -pole frame with current carrying parts omitted from center pole. SA0CUL, SA0CUL, SA0RCUL, SA0RCUL. [].9 [7] LC 0.9 [] Insulation barrier Mounting hole.9 [0.] 0.dia [ø.].7 [] 0. [] Panel drilling LC Tap or 0.7 diameter [M or ø7].0 []. [90] LC.07 [].00 [] Trip button 0.9 [.].7 [].7 [].0 [].0 []. []. [0] 0.9 []. [].9 [0.]. [7] Mx bolt.07 [].7 [9.].0 [] 0.77 [.]. [7].7 [] 0.dia [ø] 0. [].7 [] LC.7 [].-. [-] Note: -pole breaker is supplied in -pole frame with current carrying parts omitted from center pole. 0/7

81 Molded Case Circuit s Dimensions UL Listed Dimensions, inch [mm] Front mounting, front connection SARCUL. [].0 []. [90] 0.9 []. [] 0. [].00 [].07 [].7 []. [0].07 [0]. [] Insulation barrier Detachable Mounting hole 0.9 [.]. [7] 9.7 []. [7]. [7] Trip button Mx 0 bolt 0.7 dia. [ø.] ON 0.77 [.] 0.7 [7]. [7].7 [9.].0 []. [7].7 []. [.] 0.7 dia. [ø7]. [.] 0.7 [7] LC Panel drilling tap or 0.7 dia. LC [M or ø7].7 [70] Note: -pole breaker is supplied in -pole frame with current carrying parts omitted from center pole. 9.7 [] SA0RCUL.0 []. []. [90] 0.9 []. [] 0. [].07 [].7 []. [0].07 [0]. [] Insulation barrier Detachable Mounting hole 0.9 [.] 9.7 []. [7]. [7]. [7] 0.7 dia. [ø.] ON Trip button 0.77 [.] M x 0 bolt 0.9 []. [7].7 [9.].0 []. [7].7 []. [.] 0.7 dia. [ø7].7[.] 0.9 [] LC Panel drilling LC.7 [70] tap or 0.7 dia. [M or ø7] Note: -pole breaker is supplied in -pole frame with current carrying parts omitted from center pole. 9.7 [] 0 Fuji Electric FA Components & Co., Ltd./D & C Catalog 0/77

82 Molded Case Circuit s Dimensions UL Listed Dimensions, inch [mm] Front mounting, front connection EACUL LC Mounting hole. [].7 [0] LC.99 [] Terminal cover Short type 0.9 [] 0.9 [].99 [].07 [] Trip button 0. [9.].97 [] 0. [9.].00 [].9 [] ON.909 [.] LC.00 []. [] 0.09 [.] LC Panel drilling LC 0.- tap or 0.97 dia. [M or ø].07 [] Terminal section 0.9 [] 0.9 [7] 0. [] 0.7 [.] M x 0.7 [] 0. [].07 [] EACUL.7 [0] LC LC Mounting hole. [].99 [].9 [7] Terminal cover Short type.99 [].07 [] 0. [9.].97 [] 0. [9.] Trip button.00 [].9 [] ON.909 [.] LC.00 []. [] 0.09 [.] 0.- tap or 0.97 dia. [M or ø] LC LC Panel drilling.07 [] 0.9 [] Terminal section 0.9 [] 0.9 [7] 0. [] 0.7 [.] M x 0.7 [] 0. [].07 [] Dimensions for reference only. Confirm before construction begins. 0/7

83 Molded Case Circuit s Characteristic curves Line protection S and E series,, -pole SA0C, SAC, SARC EA0AC, EAAC, EAC SAC, SARC Minute Operating time Second Min. value Max. value Instantaneous tripping characteristic 9 0% (,,0A) 0. Instantaneous 0.0 tripping 0.0 characteristic (,,0,0,A) Multiple of rated current (A) Operating time correction ratio (%) Reference temp.0 C Ambient temp. ( C) Minute Operating time Second Min. value (0-A) Max. value Instantaneous (-0A) 0. tripping 0. characteristic % Multiple of rated current (A) Rated current correction ratio (%) Reference temp.0 C -0A 0-A Ambient temp. ( C) SAC, SARC EAC SAC, SARC EAC Minute Operating time Second Min. value Multiple of rated current (A) Max. value Instantaneous 0. tripping characteristic % Operating time correction ratio (%) Reference temp.0 C Ambient temp. ( C) Minute Operating time Second Min. value Max. value Instantaneous tripping characteristic 00 00% 0. Max. total fault 0. clearing time Multiple of rated current (A) Rated current correction ratio (%) Reference temp.0 C Ambient temp. ( C) 0 EAAC, EAC SA00C, SA00RC EA00C Minute Operating time Second Min. value Instantaneous tripping characteristic 00 % (A) Max. value Instantaneous tripping characteristic 9 0% (,7A) Multiple of rated current (A) Operating time correction ratio (%) Reference temp.0 C Ambient temp. ( C) Minute Operating time Second Min. value Max. value Multiple of rated current (A) Instantaneous tripping characteristic 00 00% Rated current correction ratio (%) Reference temp.0 C Ambient temp. ( C) 0/79

84 Molded Case Circuit s Characteristic curves Line protection S and E series, -pole SA0RC EA0C Minute Operating time Second Min. value Max. value Multiple of rated current (A) Instantaneous tripping characteristic 00 % Rated current correction ratio (%) Reference temp.0 C Ambient temp. ( C) SA00RC EA00C Minute Operating time Second Min. value 0 Max. value Instantaneous tripping 0. characteristic % Multiple of rated current (A) Rated current correction ratio (%) Reference temp.0 C Ambient temp. ( C) 0/0

85 Operating time Second Minute Operating time Second Operating time Second Minute Minute Molded Case Circuit s Characteristic curves Line protection S and E series, -pole SAB SA0R Max. value Min. value Max. value Instantaneous tripping characteristic 00% % Max. total fault clearing time Multiple of rated current (A) Operating time correction ratio (%) Reference temp.0 C Ambient temp. ( C) Min. value Instantaneous Multiple of rated current (A) tripping characteristic 00% % Max. total fault clearing time Rated current correction ratio (%) Reference temp. 0 C Ambient temp. ( C) EAB SA0HA Minute Max. value Minute Max. value Operating time Second Min. value Instantaneous tripping characteristic 00% % Max. total fault clearing time Multiple of rated current (A) Operating time correction ratio (%) Reference temp.0 C Ambient temp. ( C) Operating time Second 0 Min. value Instantaneous tripping characteristic 00% 00% Multiple of rated current (A) Rated current correction ratio(%) Reference temp. 0 C Ambient temp. ( C) SAR SAH Minute Max. value Min. value Max. value Multiple of rated current (A) Instantaneous tripping characteristic 00% % Max. total fault clearing time Rated current correction ratio (%) Reference temp. 0 C -0A 0-A Ambient temp. ( C) Operating time Second Min. value Instantaneous tripping characteristic 00% % Max. total fault clearing time Multiple of rated current (A) Rated current correction ratio(%) Reference temp. 0 C Ambient temp. ( C) 0/

86 Molded Case Circuit s Characteristic curves Line protection S series, -pole SA0H 0 0 Minute 0 Max. value Operating time Second Min. value Instantaneous tripping characteristic 0% 0% Multiple of rated current (A) Max. total fault clearing time Rated current correction ratio(%) Reference temp. 0 C Ambient temp. ( C) 0/

87 Molded Case Circuit s Characteristic curves Line protection L series, -pole H series,, -pole LAB HBA, HR, Minute Operating time Second Max. value 0 Min. value Max. total Instantaneous fault 0.0 tripping clearing 0.0 characteristic time % % Multiple of rated current (A) Operating time correction ratio (%) Reference temp.0 C Ambient temp. ( C) Operating time Second Minute Min. value Max. value Instantaneous tripping characteristic 00%-00% Max. total fault clearing time Multiple of rated current (A) Rated current correction ratio(%) Reference temp. 0 C Ambient temp. ( C) H series,, -pole HBA, HBA H00B, H00R 0 0 Minute 0 0 (HBA: 0, A) (HBA: 0-A) Max. value Minute Max. value 0 Operating time Second Min. value (~0A) Instantaneous tripping characteristic 00% % Max. total fault clearing time Rated current correction ratio (%) Reference temp. 0 C to 0A 0 to A Operating time Second Min. value Instantaneous tripping characteristic 00% 00% Max. total fault clearing time Rated current correction ratio(%) Reference temp. 0 C Multiple of rated current (A) Ambient temp. ( C) Multiple of rated current (A) Ambient temp. ( C) HR H0B, H0R 0 0 Minute 0 0 Max. value Minute 0 0 Max. value Operating time Second Min. value Instantaneous tripping characteristic 00% 00% Max. total fault clearing time Rated current correction ratio(%) Reference temp. 0 C Operating time Second Min. value Instantaneous tripping characteristic 00% % Max. total fault clearing time Rated current correction ratio(%) Reference temp. 0 C Multiple of rated current (A) Ambient temp. ( C) Multiple of rated current (A) Ambient temp. ( C) 0/

88 Molded Case Circuit s Characteristic curves Line protection H series, -pole H00B, H00R 0 Minute 0 0 Max. value Operating time Second 0 0 Min. value Max. total 0. fault 0. Instantaneous clearing 0.0 tripping 0.0 time characteristic 0.0 0% 0% Multiple of rated current (A) Rated current correction ratio(%) Reference temp. 0 C Ambient temp. ( C) 0/

89 Molded Case Circuit s Characteristic curves Motor protection S and E series SA0CM, SACM, SARCM EA0ACM, EACM Minute Operating time Second Min. value Max. value Instantaneous tripping characteristic 9 0% Multiple of rated current (A) Operating time correction ratio (%) Reference temp.0 C Ambient temp. ( C) SACM, SARCM EACM Minute Operating time Second Max. value 0 0 Instantaneous tripping Min. value characteristic 0 % Multiple of rated current (A) Rated current correction ratio (%) Reference temp.0 C Ambient temp. ( C) SACM EACM, EACM Minute Operating time Second Min. value Max. value Instantaneous tripping characteristic 9 0% Multiple of rated current (A) Operating time correction ratio (%) Reference temp.0 C Ambient temp. ( C) L and H series LABM Minute Operating time Second Max. value 0 0 Min. value 0. Max. total 0. fault 0. clearing 0. Instantaneous time 0.0 tripping 0.0 characteristic 0.0 0% 00% Multiple of rated current (A) Operating time correction factor (%) Reference temp Ambient temperature ( ) 0 SACM, SARCM Minute Operating time Second Min. value (090A) (A) Max. value Multiple of rated current (A) Instantaneous tripping characteristic 0 000% Rated current correction ratio (%) Reference temp.0 C -A 0-90A Ambient temp. ( C) HBAM Minute Operating time Second (0, A) Max. value 0 0 Instantaneous Min. value tripping setting range (A) 0% 000% Max. total 0. fault 0. clearing time Multiple of rated current (A) Rated current correction ratio (%) Reference temp.0 C -A 0-90A Ambient temp. ( C) 0/

90 Molded Case Circuit s Characteristic curves UL Listed S series,, -pole SARCUL Rated current :,, 0A Minute Operating time Second Min. value Max. value Instantaneous tripping characteristic 9%-0% Multiple of rated current (A) Rated current :,, 0, 0, A Minute Operating time Second Min. value Max. value Instantaneous tripping characteristic 00%-% Multiple of rated current (A) Operating time correction ratio (%) Reference temp Ambient temperature ( ) SACUL SARCUL Minute Operating time Second Min. value (0-A) Instantaneous tripping characteristic 00%-% Max. value (-0A) Max. total fault clearing time Multiple of rated current (A) Rated current correction ratio (%) Reference temp.0 C -0A 0-A Ambient temp. ( C) Minute Operating time Second Min. value (0-A) Instantaneous tripping characteristic 00%-% Max. value (-0A) Max. total fault clearing time Multiple of rated current (A) Rated current correction ratio (%) Reference temp.0 C -0A 0-A Ambient temp. ( C) SACUL SARCUL Minute Operating time Second Min. value Max. value Instantaneous tripping characteristic 00%-00% Multiple of rated current (A) Max. total fault clearing time Rated current correction ratio (%) Reference temp Ambient temperature ( ) Minute Operating time Second Min. value Max. value Instantaneous tripping characteristic 00%-00% Multiple of rated current (A) Max. total fault clearing time Rated current correction ratio (%) Reference temp Ambient temperature ( ) 0/

91 Molded Case Circuit s Characteristic curves UL Listed S series,, -pole SA00CUL SA00RCUL Minute Operating time Second Min. value Max. value Instantaneous tripping characteristic 00%-00% Max. total fault clearing time Multiple of rated current (A) Rated current correction ratio (%) Reference temp.0 C Ambient temp. ( C) Minute Operating time Second Min. value Max. value Instantaneous tripping characteristic 00%-00% Max. total fault clearing time Multiple of rated current (A) Rated current correction ratio (%) Reference temp.0 C Ambient temp. ( C) SA0RCUL SA00RCUL Minute Operating time Second Min. value Max. value Instantaneous tripping characteristic 00%-% Multiple of rated current (A) Max. total fault clearing time Rated current correction ratio (%) Reference temp.0 C Ambient temp. ( C) Minute Operating time Second Min. value Max. value Instantaneous tripping characteristic 0%-0% Max. total fault clearing 0.0 time Multiple of rated current (A) Rated current correction ratio (%) Reference temp.0 C Ambient temp. ( C) 0 E series,, -pole EACUL Rated current :,, 0,, 70, 7, 0, 90A Minute Operating time Second Min. value Max. value Instantaneous tripping characteristic 9%-0% Multiple of rated current (A) Rated current :,, 0, 0,, A Minute Operating time Second Min. value Max. value Instantaneous tripping characteristic 00%-% Multiple of rated current (A) Operating time correction ratio (%) Reference temp Ambient temperature ( ) 0/7

92 Molded Case Circuit s Accessories Variation of internal accessory Auxiliary switch (Type W) Alarm switch (Type K) Shunt trip device (Type F) This switch is used for indicator lamp or control circuit. This switch can be connected to a warning lamp or buzzer to indicate when the breaker has been tripped. The purpose of this accessory is to trip the breaker from a distance. Undervoltage trip device (Type R) The device is designed to protect circuits from harmful voltage drops. It can also be used for remote control purposes. The trip operates when the voltage drops to less than 70% of nominal coil rating, and the breaker cannot be reset until the voltage recovers % of its normal rating. Terminal block (Type A) A wiring terminal for internal accessories (Order with W, K or F) 0/

93 OFF ON OFF Molded Case Circuit s Accessories Variation of external accessory Insulation barriers The interphase barrier reinforces the insulation between terminals, while the earth barrier increases the insulation between the terminal and the mounting panel. See page 0/9 Mechanical interlock device The mechanical interlock device can be mounted onto two separate breakers to maintain a mutual ON or OFF condition. The device can also be locked with a padlock. See page 0/ Interface barrier Earth barrier External operating handles There are two handles available in the series: the V type handle on panel mount and the N type handle on breaker mount. An extension shaft (sold separately) for the V type handle allows the distance between the handle and the breaker to be adjusted. The protective structure of the V type handle operation section conforms to IP. Both handle types can be locked with a padlock conforming to IEC 0-. The panel cutout dimensions are the same for both handles. See page 0/ TRIP OPEN/RESET ON N type ON 0 TRIP Handle locking cover OFF OPEN/RESET V type Motor-operating mechanism MCCB A new drive structure in the motor operating mechanism speeds up drive operation to drastically reduce ON/OFF switching time from s to 0.s. See page 0/ Terminal covers Finger protection guards against shock from accidentally touching live terminals. Two types of terminal covers are availablelong type and short type. See page 0/ Steel enclosures Enclosures are available in three typestwo with V-type handle which allows the operation from the outside, and other direct operating. See page 0/ Long type Short type 0/9

94 Molded Case Circuit s Internal accessories Terminal blocks Terminal blocks for auxiliary circuit It indicates the terminal No. of internal accessory.the connection method of internal accessory is lead-wire system and terminal block system. Specify the connection method when ordering. It is lead-wire system unless specified. The lead wires are pulled out and terminal blocks are attached on the same side of the internal accessory will be attached For the available configuration of internal accessory, see page 0/9 to 0/9. Lead-wire wiring With terminal block IEC and CE marking conformed types Accessory Auxiliary switch SPDT: W 0 AF Left side mounting Right side mounting 00 00AF Left side mounting AXcL AXbL AXaL AXcR AXbR AXaR AXc AXb AXa PDT: W AXcL AXbL AXaL AXcR AXbR AXaR AXc AXb AXa AXc AXb AXa Alarm switch SPDT: K 9 ALcL 9 ALbL 9 ALaL 0 ALcR 0 ALbR 0 ALaR 9 ALc 9 ALb 9 ALa PDT: K 9 ALcL 9 ALbL 9 ALaL 0 ALcR 0 ALbR 0 ALaR 9 ALc 9 ALb 9 ALa 0 ALc 0 ALb 0 ALa Shunt trip device : F With NO contact to prevent coil burn-out Continuous rating C S C S Undervoltage trip device : R C S U< C S D P D P 0/90

95 Molded Case Circuit s Internal accessories Terminal blocks L series, H series Accessory Auxiliary switch SPDT: W Terminal number LAB, HR, HR, H00R, H0R, H00R HBA, HBA, HBA, H00B, H0B, H00B AXC AXa AXb PDT: W AXa AXC AXb AXa AXC AXb Alarm switch SPDT: K ALa ALC ALb PDT: K ALa ALC ALb ALa ALC ALb 0 Shunt trip device : F With NO contact to prevent coil burn-out S S Continuous rating S S Undervoltage trip device : R AC LAB, HBA HR, HBA HR, HBA H00R, H00B H0R, H0B H00R, H00B P P DC LAB, HBA HR, HBA HR, HBA H00R, H00B H0R, H0B H00R, H00B P P 0/9

96 Molded Case Circuit s Internal accessories Available configurations P P Left Right Right Handle MCCB S series SAC SAC SARC SAC SARC E series H L series EAAC EAAC EAC EAC EAC Handle SAC SAC SAC SARC SAC SARC SAC SARC SARC SA0C SA0C SA0RC SA0RC EAAC EA0C EAAC EA0C EAC, C EAAC EAC Undervoltage trip: R Shunt trip: F SA0C SA0C SA0RC SA0RC SARC SA0RC EA0C EA0C EAC EA0C SAB* SAR SA0R EAB * Auxiliary switch: W SA0HA LAB H0B, H0B HR, 0R H0R HBA, BA HB, HR HBA, BA H0B, H0R H0BA, 0BA * SAH SA0H Alarm switch: K Pole Auxiliary switch SPDT W Alarm switch SPDT K Shunt trip F,,, Undervoltage trip R W * * * W+K W+K K W+K W+K W+F W+F W+R * * * W+R * * K+F K+R * * * W+K+F W+K+R * * * K+F K+R W+K+F * W+K+R * W+K+F W+K+R W+K+F W+K+R Notes: The lead wires are pulled out and terminal blocks are attached on the same side of the accessory.attached. * The "W" and "K" of EAB and SAB are mounted on the left pole only. They cannot be mounted on the right side pole. * The side on which the undervoltage trip device "R" is mounted has the terminal block. * H00R, H0R, H00R: Factory-mounted 0/9

97 Molded Case Circuit s Internal accessories UL listed Available configurations P P Left Right Right Handle Handle MCCB S series SARCUL * SARCUL * Undervoltage trip: R Shunt trip: F SACUL SACUL SARCUL SARCUL SA0CUL SA0CUL SA0RCUL SA0RCUL Auxiliary switch: W SA0CUL SA0CUL SA0RCUL SA0RCUL SARCUL SA0RCUL Alarm switch: K E series EACUL * EACUL * Pole Auxiliary switch SPDT W Alarm switch SPDT K Shunt trip F,, Undervoltage trip R W 0 W+K W+K K W+K W+K W+F W+F W+R W+R K+F K+R W+K+F W+K+R K+F K+R W+K+F W+K+R W+K+F W+K+R W+K+F W+K+R Notes: The lead wires are pulled out and terminal blocks are attached on the same side of the accessory.attached. * Terminal block connection is standard method 0/9

98 Molded Case Circuit s Internal accessories Type number nomenclature of internal accessory Up to AF BZ WK L C A (CCC) Optional accessories Type of accessories W: Auxiliary switch WD: Aux. switch for low level circuit K: Alarm switch KD: Alarm switch for low level circuit WK: Aux. and alarm switches WDKD: Aux. and alarm switches for low level circuit F : Shunt trip device R : Undervoltage trip device (CCC): CCC approved Wiring Blank : Lead-wire wiring A : With terminal block Applicable breakers C : Up to SARC, EAC 0C : SAC, SARC 0C : SAC, SARC, EAC : Operating voltage code See page 0/ Terminal block installation position L : Left side of breaker R : Right side of breaker 00AF to 00AF BZ - WKF 70B - - A (CCC) Optional accessories Type of accessories W : Auxiliary switch K : Alarm switch F : Shunt trip device R : Undervoltage trip device (CCC): CCC approved Wiring Blank : Lead-wire wiring A : With terminal block Operating voltage code See page 0/ Applicable breakers 70B : 00AF to 00AF 0/9

99 Molded Case Circuit s Internal accessories Operation of auxiliary switches(w) and alarm switches(k) Accessory Handle position ON OFF Trip Auxiliary switch /AXcL /AXaL /AXcL /AXaL SPDT: W /AXbL /AXbL /AXcL /AXaL /AXcL /AXaL PDT: W /AXbL /AXbL /AXcR /AXaR /AXcR /AXaR /AXbR /AXbR Alarm switch 9/ALcL 9/ALaL 9/ALcL 9/ALaL SPDT: K 9/ALbL 9/ALbL 9/ALcL 9/ALaL 9/ALcL 9ALaL PDT: K 9/ALbL 9/ALbL 0/ALcR 0/ALaR 0/ALcL 0/ALaL 0/ALbR 0/ALbL For L series H series Auxiliary switch SPDT: W AXc AXa AXb AXc AXa AXb 0 PDT: W AXc AXa AXc AXa AXb AXb Alarm switch SPDT: K ALc ALa ALb ALc ALa ALb PDT: K ALc ALa ALc ALa ALb ALb Note: Ring mark indication 0/9

100 Molded Case Circuit s Internal accessories Ratings of auxiliary switches(w) and alarm switches(k) Standard type Applicable breaker type S series E series SA0C SAC SARC SAC SARC SAC SARC SAC SARC EA0AC EAAC EAC EAC EAAC EAC EAC H and L series LAB, HBA HBA, HR HBA, HR AC Voltage (V) 0 Make/break current (A) Res. load () () () () () () Ind. load () () () () () () DC Voltage (V) Make/break current (A) Res. load () 0. (0.) 0. (0.) () 0. (0.) 0. () 0. (0.) Ind. load () 0. (0.) 0. (0.) () 0. (0.) 0. () 0. (0.) Minimum load current V DC ma 0V DC 0mA 0. (0.) 0. (0.) SA00C SA00RC SA0RC SA00RC EA00C EA0C EA00C H00B H00R H0B H0R H00B H00R Note: ( ) Rep. value for IEC9-- or JIS C0-- Low level circuit Applicable breaker type S series E series SA0C SAC SARC SAC SARC SAC SARC SAC SARC SA00C SA00RC SA0RC SA00RC EA0AC EAAC EAC EAC EAAC EAC EAC EA00C EA0C EA00C H and L series HBA, LAB HBA, HR HBA, HR H00B, H00R H0B, H0R H00B, H00R DC Voltage (V) Make/break current (A) (Res. load) Minimum load current V DC ma 0V DC ma 0/9

101 Molded Case Circuit s Internal accessories UL Listed Operation of auxiliary switches(w) and alarm switches(k) Accessory Auxiliary switch SPDT: W Handle position ON OFF Trip /AXcL /AXaL /AXcL /AXaL /AXbL /AXbL /AXcL /AXaL /AXcL /AXaL PDT: W /AXbL /AXbL /AXcR /AXaR /AXcR /AXaR /AXbR /AXbR Alarm switch 9/ALcL 9/ALaL 9/ALcL 9/ALaL SPDT: K 9/ALbL 9/ALbL 9/ALcL 9/ALaL 9/ALcL 9ALaL PDT: K 9/ALbL 9/ALbL 0/ALcR 0/ALaR 0/ALcL 0/ALaL 0/ALbR 0/ALbL Note: Ring mark indication 0 Ratings of auxiliary switches(w) and alarm switches(k) Standard type MCCB S series SARCUL SACUL SARCUL SACUL SARCUL SA00CUL SA00RCUL SA0RCUL SA00RCUL E series EACUL AC Voltage (V) Make/break current (A).. DC Voltage (V) Make/break current (A) Minimum load current V DC ma 0V DC 0mA Low level circuit MCCB S series E series DC Voltage (V) Make/break current (A) Minimum load current SARCUL SACUL SARCUL SACUL SARCUL SA00CUL SA00RCUL SA0RCUL SA00RCUL EACUL V DC ma 0V DC ma 0/97

102 Molded Case Circuit s Internal accessories Rating of shunt trip (F) IEC and CE marking conformed MCCB type S series E series H and L series SA0C SAC SARC SAC SARC SAC SARC SAC SARC SA00C SA00RC SA0RC SA00RC EA0AC EAAC EAC EAC EAAC EAC EAC EA00C EA0C EA00C Note: Allowable voltage function HBA LAB HBA HR HBA HR H00B H00R H0B H0R H00B H00R Power consumption AC V - (/Hz) 00-0 (/Hz) 0- (/Hz) (/Hz) (/Hz) - (/Hz) 00-0 (/Hz) 0- (/Hz) 0-0 (/Hz) - (/Hz) -0 (/Hz) 0- (/Hz) AC voltage: % to % of coil rated voltage DC voltage: 7% to % of coil rated voltage VA 00 0 DC V W Time rating of coil Continuous With NO contact to prevent coil burn-out Continuous With NO contact to prevent coil burn-out Continuous Operating time (ms) UL Listed MCCB type S series SARCUL E series EACUL SACUL SARCUL SACUL SARCUL SA00CUL SA00RCUL SA0RCUL SA00RCUL Note: Allowable voltage function H and L series Power consumption AC V - (/Hz) 00-0 (/Hz) 0- (/Hz) (/Hz) (/Hz) - (/Hz) 00-0 (/Hz) - (/Hz) -0 (/Hz) AC voltage: % to % of coil rated voltage DC voltage: 7% to % of coil rated voltage VA 00 0 DC V W Time rating of coil Continuous With NO contact to prevent coil burn-out Continuous Continuous Operating time (ms) /9

103 Molded Case Circuit s Internal accessories Rating of undervoltage trip (R) IEC and CE marking conformed MCCB type S series E series H and L series SA0C SAC SARC SAC SARC SAC SARC SAC SARC SA00C SA00RC SA0RC SA00RC EA0AC EAAC EAC EAC EAAC EAC EAC EA00C EA0C EA00C HC HC HC LAB * H BA * HBA * HR * HBA * HR * H00B H00R H0B H0R H00B H00R Notes: Specify the operating voltage when ordering. * Terminal block connection is standard method. Power consumption AC V (Hz)/-(Hz) 00(Hz)/00-0(Hz) 00(Hz)/00-0(Hz) (Hz)/-(Hz) 00(Hz)/00-0(Hz) 00(Hz)/00-0(Hz) (/Hz) (/Hz) - (/Hz) 00-0 (/Hz) 0-0 (/Hz) 0-0 (/Hz) (/Hz) (/Hz) - (/Hz) 00-0 (/Hz) 0-0 (/Hz) VA DC V W Operating voltage Tripping voltage: 70 to % of coil rating voltage Closing voltage: % or more of coil rating voltage 0 UL type MCCB type S series SARCUL SACUL SARCUL SACUL SARCUL SA00CUL SA00RCUL SA0RCUL SA00RCUL E series EACUL H and L series Power consumption AC V (Hz)/-(Hz) 00(Hz)/00-0(Hz) 00(Hz)/00-0(Hz) (Hz)/-(Hz) 00(Hz)/00-0(Hz) 00(Hz)/00-0(Hz) (/Hz) (/Hz) - (/Hz) 00-0 (/Hz) VA DC V W 00 Operating voltage Tripping voltage: 70 to % of coil rating voltage Closing voltage: % or more of coil rating voltage 0/99

104 Molded Case Circuit s Internal accessories Dimensions, mm Shunt trip device "F" and undervoltage trip device "R" S series E series Fig. Mass (kg) SA0C SAC, SARC SAC, SARC EA0AC EAAC, EAC EAC EAAC, EAC Fig. 0. SAC, SARC Fig. 0.7 SAC, SARC EAC Fig. 7. M M. Fig. Fig. 7. M. 7 Fig. 0/

105 Molded Case Circuit s Internal accessories Lead wire specifications IEC and CE marking conformed S series SA0C SAC, SARC SAC, SARC SAC, SARC SAC, SARC SA00C, SA00RC SA0RC SA00RC S0 S SE UL Listed S series SACUL, SARCUL SACUL, SARCUL SA00CUL, SA00RCUL SA0RCUL SA00RCUL E series EA0A EAAC, EAC EAC EAAC, EAC EAC EA00C EA0C EA00C E series L and H series LAB HBA HBA, HR HBA, HR H00B, H00R H0B, H0R H00B, H00R L and H series Wire size AWG (0.mm ) 0.mm Wire size 0AWG Wire length 0mm 0mm Wire length 0mm Terminal block specifications MCCB type S series SA0C SAC, SARC SAC, SARC SARCUL * SAC, SACUL SARC, SARCUL SAC, SACUL SARC, SARCUL SA00C, SA00CUL SA00RC, SA00RCUL SA0RC, SA0RCUL SA00RC, SA00RCUL Notes: Lead wire ø. or mm Fig. 7 E series EA0AC EAAC, EAC EAC EAAC, EAC EACUL * EAC EA00C EA0C EA00C L and H series HBA, HBA HBA HR, HR LAB H00B, H00R H0B, H0R H00B. H00R * Lead wire pull-out type are not available E Fig. D C 7 Terminal screw M. Dimensions (mm) Fig. Fig. A 0 B. Fig. Fig. E D C Fig C D.... E F A +A B. B Fig. (Left) Line 7 (Right) E D C +A 9 Fig. 7. F +A Line Load M.. B 9. 0 M. (Left) Lead-wire extension type is not available. (EACUL, SARCUL) Load (Right) 0/

106 Molded Case Circuit s Internal accessories Type number Auxiliary switches (W) and alarm switches (K) MCCB type S series E series Type number Auxiliary switch / W SPDT: W Mass(kg) PDT: W Mass(kg) Alarm switch / K SPDT: K Mass(kg) PDT: K Mass(kg) Auxiliary switch + Alarm switch / WK Mass (kg) SA0C * SAC * SARC * SAC * SARC * EA0AC * EAAC * EAC * EAC * EAAC * EAC * BZW C BZW CA (With terminal block) BZK C BZK CA (With terminal block) BZWK C BZWK CA (With terminal block) SAC SARC BZW 0C BZW 0CA (With terminal block) BZK 0C BZK 0CA (With terminal block) BZWK 0C BZWK 0CA (With terminal block) SAC SARC EAC BZW 0C BZW 0CA (With terminal block) BZK 0C BZK 0CA (With terminal block) BZWK 0C BZWK 0CA (With terminal block) SA00C SA00RC SA0RC SA00RC EA00C EA0C EA00C BZ-W70B BZ-W70B-A (With terminal block) BZ-W70B BZ-W70B-A (With terminal block) BZ-K70B BZ-K70B-A (With terminal block) BZ-K70B BZ-K70B-A (With terminal block) BZ-WK70B BZ-WK70B-A (With terminal block) MCCB type L series H series Type number Auxiliary switch / W SPDT: W Alarm switch / K SPDT: K Auxiliary switch + Alarm switch / WK LAB BZ-WB BZ-KB BZ-WKB HB HBA BZ-WB BZ-KB BZ-WKB HBA BZ-W0B BZ-K0B BZ-WK0B HR HR BZ-WB BZ-KB BZ-WKB H00B H0B H00B BZ-W70B BZ-K70B BZ-WK70B UL Listed MCCB type S series E series Type number Auxiliary switch / W SPDT: W Alarm switch / K SPDT: K Auxiliary switch + Alarm switch / WK SARCUL EACUL BZW CU BZW CAU (With terminal block) BZK CU BZK CAU (With terminal block) BZWK CU BZWK CAU (With terminal block) SACUL SARCUL BZW 0CU BZW 0CAU (With terminal block) BZK 0CU BZK 0CAU (With terminal block) SACUL SARCUL BZW 0CU BZW 0CAU (With terminal block) BZK 0CU BZK 0CAU (With terminal block) SA00CUL SA0CUL SA00CUL Notes: Auxiliary switch and alarm switch for low level circuit are also available on request, in this case add D to the type number when ordering. Example: WD, KD Replace the mark by the R when an auxiliary switch or an alarm switch is mounted on right hand side of the breaker. Enter the L when it is mounted on left hand side of the breaker. * -pole types are mountable on right side only. Factory-mounted accessory 0/

107 Molded Case Circuit s Internal accessories Shunt trip devices (F) MCCB type S series SA0C SAC SARC SAC SARC SAC SARC SAC SARC SA00C SA00RC SA0RC SA00RC E series EA0AC EAAC EAC EAC EAAC EAC EAC EA00C EA0C EA00C Operating voltage Code Voltage A -V AC /Hz, -V DC K 00-0V AC /Hz P 0-V AC /Hz R S T U P R S T U P 0 V AC /Hz, V DC V AC /Hz, V DC -V AC /Hz, -V DC 00-0V AC /Hz, 00-0V DC 0-V AC /Hz V AC /Hz, V DC V AC /Hz, V DC -V AC /Hz, -V DC 00-0V AC /Hz, 00-0V DC 0-V AC /Hz -V AC /Hz, -V DC -0V AC /Hz, -0V DC 0-V AC /Hz Type number BZFAC BZFKC BZFPC BZFR0C BZFS0C BZFT0C BZFU0C BZFP0C BZFR0C BZFS0C BZFT0C BZFU0C BZFP0C BZ-F70B- BZ-F70B- BZ-F70B-0 With terminal block BZFACA BZFKCA BZFPCA BZFR0CA BZFS0CA BZFT0CA BZFU0CA BZFP0CA BZFR0CA BZFS0CA BZFT0CA BZFU0CA BZFP0CA BZ-F70B--A BZ-F70B--A BZ-F70B-0-A Undervoltage trip devices (R) MCCB type S series SA0C SAC SARC SAC SARC SAC SARC SAC SARC SA00C SA00RC SA0RC SA00RC E series EA0AC EAAC EAC EAC EAAC EAC EAC EA00C EA0C EA00C Notes: Specify operating voltage with ordering. Terminal block Operating voltage Code Voltage V AC Hz/-V AC Hz V AC Hz/-7V AC Hz W 00V AC Hz/00-0V AC Hz 0V AC Hz/0-0V AC Hz 0V AC Hz/0-0V AC Hz 0V AC Hz 0 0V AC Hz/0-V AC Hz 9 00V AC Hz/00-0V AC Hz F V DC T -V DC V AC Hz/-V AC Hz 00V AC Hz/00-0V AC Hz C 00V AC Hz/00-0V AC Hz T -V DC R V AC /Hz, V DC S V AC /Hz, V DC X -V AC /Hz, -V DC U 00-0V AC /Hz, 00-0V DC E 0-0V AC /Hz Type number BZRC BZRC BZRWC BZRC BZRC BZRC BZR0C BZR9C BZRFC BZRTC BZ-R70B- BZ-R70B- BZ-R70B- BZ-R70B-00 BZ-R70B-0 Operating voltage Tripping voltage: 70 to % of coil rated voltage Closing voltage: % or more of coil rated voltage Factory-mounted accessory When ordering, specify the rated voltage. 0 0/

108 Molded Case Circuit s Internal accessories UL Listed Shunt trip devices (F) MCCB type S series SARCUL SACUL SARCUL SACUL SARCUL SA00CUL SA00RCUL SA0RCUL SA00RCUL E series EACUL Rated voltage -V AC /Hz 00-0V AC /Hz 0-V AC /Hz -V AC /Hz 00-0V AC /Hz -V AC /Hz 00-0V AC /Hz V /Hz V /Hz -0V /Hz Type number Lead wire BZFACU BZFKCU BZFPCU BZFT0CU BZFU0CU BZFT0CU BZFU0CU With terminal block BZFACAU BZFKCAU BZFPCAU BZFT0CAU BZFU0CAU BZFT0CAU BZFU0CAU Factory-mounted accessory UL Listed Undervoltage trip devices (R) MCCB type S series SARCUL E series EACUL Rated voltage V AC Hz/-V AC Hz 00V AC Hz/00-0V AC Hz 00V AC Hz/00-0V AC Hz Type number Lead wire With terminal block BZRCAU BZRWCAU BZR9CAU 0/

109 Molded Case Circuit s Internal accessories Internal accessories (optional) for 00AF to 00AF Accessory type Auxiliary switch Alarm switch Shunt trip Undervoltage trip Number Mass (kg) W W K K F R of terminal w/lead w/terminal blocks wire block BZ-W70B BZ-K70B BZ-F70B BZ-R70B BZ-W70B BZ-WK70B BZ-WK70B BZ-K70B BZ-WK70B BZ-WK70B BZ-WF70B BZ-WF70B BZ-WR70B BZ-WR70B BZ-KF70B BZ-KR70B BZ-WKF70B BZ-WKR70B BZ-KF70B BZ-KR70B BZ-WKF70B BZ-WKR70B BZ-WKF70B BZ-WKR70B BZ-WKF70B BZ-WKR70B Notes: Indicates the mountable accessories. Replace the mark by the operating voltage of shunt trip or undervoltage trip device. Replace the mark by the A suffix for terminal block type, blank for lead-wire connection type. 0 Operating voltage for 00AF to 00AF BZ - WKF 70B - - A Type of accessory Operating voltage Terminal Operating voltage Shunt trip /V AC/DC -0V AC -0V DC 0-V AC Undervoltage trip V AC/DC V AC/DC -V AC/DC 00-0V AC 00-0V DC 0-0V AC Code Ordering information Specifty the following.. Type number. Lead-wire connection or terminal block type 0/

110 Molded Case Circuit s External accessories Motor-operated breakers Motor-operated breakers Description The breaker is fitted with a motor operating mechanism which enables ON, OFF and RESET operations to be carried out electronically by remote control. -pole motor operated breakers are also available. AF0- to AF CP- 00 to 00AF AF9-0 Types and ratings S series E series Motor rating Operating voltage Operating time Time rating Power source capacity SAC/M SAC/M, RC/M SAC/M, RC/M EAAC/M EAAC/M, C/M EAC/M EAAC/M, C/M V DC /V AC 00/0V AC 0.s s per on-off operation 0VA SAB/M SAC/M SARC/M, RC/M SAR/M SA0C/M, 0C/M SA0RC/M, 0RC/M SA0R/M EAB/M EA0C/M, 0C/M V DC V DC V DC /V AC 00/0V AC s.s 0s 0s VA VA SA0C/M, 0C/M SA0RC/M, 0RC/M SARC/M SA0RC/M SA0HA/M EA0C/M, 0C/M EAC/M EA0C/M /V DC /V AC 00/0V AC s 0s VA at /V DC, /V AC 00VA at 00/0V AC SAH/M SA0H/M.s 0s 0VA Ordering information Specify the following:. Type number. Motor operating voltage Dimensions, mm / Front mounting, front connection SAC/M, SAC/M, SARC/M, SAC/M, SARC/M EAAC/M, EAAC/M, EAC/M, EAC/M, EAAC/M, EAC/M Panel drilling Mounting hole ø. LC Insulation barrier (Except EAAC/M, AC/M, SAC/M) Operating handle M or ø Wiring diagrams /V AC, 00/0V AC, V DC DRIVE UNIT CONTROL CIRCUIT 7 L C E OFF ON 70 7 Terminal cover Trip button 9 7 Notes: Trip button operation can be carried out at right side of the breaker. IEC mm wide mounting rail is not available. Power supply (Non polarity) 0/

111 Molded Case Circuit s External accessories Motor-operated breakers Dimensions, mm / Front mounting, front connection SARC/M, SARC/M, SAC/M Wiring diagrams V DC, V DC, V DC Insuration barrier Detachable Panel drilling R 7 -M or ø 0 9 Max /V AC, 00/0V AC SA0C/M, SA0C/M, SA0RC/M, SA0RC/M EA0C/M, EA0C/M Insuration barrier Detachable 0 Panel drilling 0 R 7 -M or ø 7 Note: Interphase insulation barriers are standard provided for the front mounting type breakers of AF to AF. 9 C : Control relay for breaker closing T : Control relay for breaker open M : Motor Ca-Cc : Relay terminal number for closing Ta-Tc : Relay terminal number for open : Diode Z : Z-trap (Surge absorber) SS : ON/OFF changeover switch E, - : Terminal number for external wire connection : Resistor : LED : DB (Silicon diode) : Transformer : Capacitor AURS : Automatic reset switch (supplied on request) 0/7

112 Molded Case Circuit s External accessories Motor-operated breakers Dimensions, mm/front mounting, front connection SA0C/M, SA0C/M, SA0RC/M, SA0RC/M EA0C/M, EA0C/M 0 Panel drilling Panel Manual/ motor operation indicator Bolt M x M M or ø7 SARC/M, SA0RC/M, EAC/M, EA0C/M 0 0 Panel drilling C A Panel Manual/ motor operation indicator M 7 Bolt M x 0 9 C B 70 ø7 Amp. frame A (line side) B (load side) C 0AF AF.. Dimensions for reference only. Confirm before construction begins. 0/

113 Molded Case Circuit s External accessories Motor-operated breakers Type (MCCB with motor operating mechanism) SAC/M, SAC/M, SARC/M EAAC/M, EAAC/M, EAC/M SAC/M, SARC/M EAC/M, EAAC/M, EAC/M SAC/M, SARC/M, SA0RC/M, SA0C/M EA0C/M SARC/M SA0C/M, SA0RC/M EA0C/M SA0C/M, SA0RC/M EA0C/M SA0C/M, SA0RC/M, EA0C/M SARC/M, EAC/M SA0RC/M, EA0C/M Mass (kg) Wiring diagrams/00 to 00AF /V AC, 00/0V AC, /Hz /V DC C : Control relay for breaker closing R : Resistor T : Control relay for breaker open LS : Limit switch M : Motor AURS: Automatic reset switch (supplied on request) 0/9

114 Molded Case Circuit s External accessories Mechanical interlocking device Mechanical interlocking devices Description These interlocking devices are mounted on the two separate breakers to prevent them from both being closed at the same time. They employ a slide method and are operated manually. These interlocking devices is possible to lock with a padlock (not supplied). They are designed for use when changing over power supplies. These can be mounted to types of breakers: front-mounting frontconnection type, front-mounting rearconnection type (type X), and plug-in mounting type (type P). Interlock devices for flush mounting type breakers (type E, Y) are also available. M types Types and applicable breakers Type BZMC BZMC BZ-MC- BZMC BZMC BZ-MC- BZM0C BZ-MC- BZ-MC BZ-M70C type S series SAC, SAC, SARC SAC, SARC SAC, SAC, SARC SAC, SARC SAB SAC SAC SARC, SARC SAR SA0C, SA0C SA0RC, SA0RC SA0R SA0C, SA0C SA0RC, SA0RC SARC, SA0RC E series EAAC, EAAC, EAC EAC, EAC EAAC, EAAC, EAC EAC, EAAC, EAC EAB EA0C, EA0C EA0C, EA0C EAC, EA0C 0/

115 Molded Case Circuit s External accessories Mechanical interlocking device Dimensions, mm 0AF to EAAF B C A BZMC Panel drilling of slider mounting hole of breaker of breaker Padlock (Not supplied) -ø. mounting hole -ø. or M BZMC mounting hole of breaker 9 -ø. or M Type type S series E series Dimensions, mm A B C Mass (kg) 0 BZMC SAC SAC SAC SARC SARC EAAC EAAC EAC EAC EAC. 0. BZMC SAC SAC SAC SARC SARC EAAC EAAC EAAC EAC EAC EAC 0. Notes: BZMC is not available for padlock. Applicable padlock(ø.) dimensions, mm 9. ø. ø. 0 Dimensions for BZ-MC-, BZ-MC-, BZ-MC-: Contact FUJI 0/

116 Molded Case Circuit s External accessories Mechanical interlocking device Dimensions, mm SAAF to SA/EAAF A A' C E F Panel drilling BZMC BZMC J H J -M or ø H of handle N N of slider K B D K G P of breaker Q Padlock (not supplied) Mounting screw (provided) J' J' -M or ø 00AF to 00AF of handle A' A C of slider F E of slider -M or ø BZM0C J H J N N BZ-MC, M70C, M J H of handle J B D G K P of breaker L of breaker Q J' J' J' J' M or ø7 Padlock (not supplied) Mounting screw (Provided) Type type S series E series Dimensions, mm A (A') B C D E F G H J (J') K L N P Q Mass (kg) BZMC SAC () BZMC SAC SARC SARC () () BZM0C SA0C SA0C SA0RC SA0RC EA0C EA0C 0 (.) 7. (.) BZ-MC SA0C SA0C SA0RC SA0RC EA0C EA0C (70) (70) 0. BZ-M70C SARC SA0RC EAC EA0C 0 () () 0. Note: Applicable padlock(ø.) dimensions, mm 9. ø. 0 0/

117 Molded Case Circuit s External accessories Operating handles External operating handles Description Molded case circuit breaker handles are generally directly manual-operated but when mounted in motor control centers or on control panels they are sometimes required to be operated externally. To meet such applications FUJI offers the following three types of handles. N type handle This type has a knob handle directly attached to the breaker. It is easily fitted by cutting a hole in the panel, which is provided with a door interlock. They may be fitted to all breakers up to ampere frame sizes. N type handles for SA/EA0AF to EAAF are approved by UL. V type handle The V type handle may be fitted to breakers of up to 00AF. A separately sold extension shaft (BZ-VS)provides distance adjustment between the handle and breaker. Conformed to EN97- isolation function. Available for EN0- power breaking device. G type handle The G type handle is mounted on the panel, and also has a door-interlock. G type handle with a cylinder lock key is also available on request. G type handle with a padlockable handle lock plate is standard provided for circuit breaker of up to AF, and is optional for 00AF and larger. KK0-07 AF9-7 KK0-0 SG- BZNC BZ-N C BZVC G- A N type handles V type handle G type handle N type handles BZ-N N type handle on breaker V type handles BZV C Decorative plate C V type handle on panel 0 G type handles G- A G type handle on panel 0/

118 Molded Case Circuit s External accessories Operating handles For breakers up to 00AF N type handles S series E series SAC, C SAC, C SARC, RC SAC, C SARC, RC SAC, C SARC, RC SA0C, 0C SA0RC, 0RC SA0C, 0C SA0RC, 0RC SARC, 0RC S series SARCUL, RCUL SACUL, CUL SARCUL, RCUL SA0CUL, 0CUL SA0RCUL, 0RCUL SA0CUL, 0CUL SA0RCUL, 0RCUL SARCUL, 0RCUL Note: EAAC, AC EAAC, AC EAC, C EAC, C EAAC, C, C EA0C, 0C EA0C, 0C EAC, 0C E series EACUL, CUL N type handle BZNC UL (File No. E77) BZ-N0C BZ-N0C BZ-NC BZ-N70C N type handle UL9 (File No. E99) BZNCP BZN0CP BZN0CP BZNCP BZN70CP N type handles for up to 00AF can be padloked. Padlock is not provided. N type handles are not CE marked. V type handles S series SAC, C SAC, C SARC, RC SAC, C SARC, RC SARCUL, RCUL SAC, C SACUL, CUL SARC, RC SARCUL, RCUL SA0C, 0C SA0CUL, 0CUL SA0RC, 0RC SA0RCUL, 0RCUL SA0C, 0C SA0CUL, 0CUL SA0RC, 0RC SA0RCUL, 0RCUL SARC, 0RC SARCUL, 0RCUL E series EAAC, AC EAAC, AC EAC, C EAC, C EAAC, C, C EACUL, CUL EA0C, 0C EA0C, 0C EAC, 0C V type handle BZVC UL9 (File No. E99) BZV0C UL9 (File No. E99) BZV0C UL9 (File No. E99) BZVC UL9 (File No. E99) BZV70C UL9 (File No. E99) For breakers other than N type handles series V type handles S series SAB SAR SA0R SA0HA SAH, 0H E series EAB L, H series LAB HBA, BA HBA, BA H0BA, 0BA HR, 0R H0B, 0B, 0R HB, R H0B, 0R N type handle BZ-N0C BZ-N0C BZ-NB BZ-N0C BZ-NC BZ-NB BZ-NC BZ-N70C N-A N-A S series SAB E series EAB L, H series LAB HBA, BA HBA, BA H0BA, 0BA HR, 0R H0B, 0B, H0R HB, R H0B, 0R V type handle BZ-V0C BZ-V0C BZ-V0C BZ-VC BZ-VC BZ-V70C G type handles Type SAR SA0R SA0HA SAH, 0H Standard BZ-GC BZ-GC G-A G-A Cylinder key type BZ-GC-K BZ-GC-K G-A-K G-A-K 0/

119 Molded Case Circuit s External accessories N type operating handles N type operating handles Operating instructions. MCCB operation Close the door with the handle in the OFF position. Turn the handle to the ON position and the MCCB will be ON. Turn the handle to the OFF position and MCCB will be OFF. When the breaker trips, the handle moves to the TRIP position. To reset, move the handle to the RESET position. Fig. Mounting screw For NC, N0C, N0C Base plate. Door locking The door cannot be opened when the handle is in the ON, OFF or TRIP position, and can be opened only when the handle is in the OPEN position. The breaker cannot be ON when the door is open. If it is necessary to open the door with the breaker closed, turn the door lock release screw counterclockwise using a screwdriver.. Handle locking The handle can be locked in either the ON or OFF position when a padlock (not supplied) is used. Pull out the handle lock plate and fit your padlock to the lock plate. If the breaker trips while it is locked in the ON position, the handle moves to the TRIP position. For N0C Fig. For NC, N0C, N0C Installation BZNC, BZ-N0C, BZ-N0C, BZ-N0C. Drilling and cutting the door Drill and cut the door. The dimensions for drilling and cutting are the same whether the MCCB is installed horizontally or vertically. Decorative plate Retaining plate 0. Preparing a base plate (Fig. ) Prepare a base plate to adjust breaker mounting position (base plate: not supplied). Front mounting, front connection type breakers can only be suitable for this handle. Drill the breaker mounting holes on the base plate. Fig. Not correct. Fitting the N-handle mechanism and MCCB to the base plate (Fig. ) Commonly tighten the N-handle body and MCCB to the base plate with the mounting screws. For NC to N0C, tighten two mounting screws on a diagonal line, and for N0C, tighten four mounting screws. Assemble the driving unit so that the breaker handle engages the N handle arm. (Fig. ) MCCB MCCB. Mounting the decorative plate Mount the decorative plate and the retaining plate to the door with screws provided. (Fig. ) Adjust the position of the handle unit so that it does not tilt against the breaker. (Fig. ) Space Fig. Handle window Decorative plate Decorative plate MCCB handle N handle arm 0/

120 Molded Case Circuit s External accessories N type operating handles Installation BZ-NC, BZ-N70C. Drilling and cutting the door Drill and cut the door. The dimensions for drilling and cutting are the same whether the MCCB is installed horizontally or vertically. Fig.. Preparing a base plate (Fig. ) Prepare a base plate to adjust breaker mounting position (base plate: not supplied). Front mounting, front connection type breakers can only be suitable for this handle. Drill the breaker mounting holes on the base plate.. Fitting the N-handle mechanism and MCCB to the base plate (Fig. ) Commonly tighten the N-handle body and MCCB to the base plate with the four mounting screws. Assemble the driving unit so that the breaker handle engages the N handle arm. (Fig. ). Mounting the decorative plate Mount the decorative plate and the retaining plate to the door with screws provided. (Fig. ) Adjust the position of the handle unit so that it does not tilt against the breaker. (Fig. ) Fig. Fig. Fig. MCCB Handle window Not correct Decorative plate N handle arm Decorative plate Space MCCB MCCB handle Type number nomenclature BZ N C T R Installation Blank: Vertically R: Horizontally, right line side L: Horizontally, left line side Door locking device Blank: Provided T: Not provided Basic type BZNC BZ-N C N- A Note: To order an N handle for front-mounting rear connection breakers, add -X to the type number, for plug-in mounting breakers, add -P to the type number. 0/

121 OPEN Molded Case Circuit s External accessories N type operating handles Dimensions, mm BZNC to BZ-NC (Dust proof paking: BZ-NP-C, optional) Line Load 9 max. type SA0C, SAC, RC, SAC, RC SARCUL EA0AC, EAAC, C, EAC EAAC, C, CUL LAB SAC, RC, CUL, RCUL HBA, BA Handle type BZNC BZ-N0C BZ-N0C A Mounting Mass Screw (kg) M M 0. M 0. type EAC SAC, RC, CUL, RCUL HBA HR, HR Handle type BZ-N0C BZ-NC A Mounting Mass Screw (kg) M 0. M 0. BZ-NC, BZ-N70C (Dust proof packing: BZ-NP-, optional) Line Mounting screw Door panel cutting 0 9 I T R P O N Decorative plate Lock plate -ø Handle C/L RESET O F F RELEASE and handle C/L and handle C/L ø 9 7 Aux. handle (Only BZ-N70C) Load Door hinge installation area P 7. 7 Panel thickness. to. Note: Handle protection degree IP (IEC9, JIS C 090) (with the optional dust-proof packing) The handle cannot hold the door. Notes:. The N type handles are used with front mounting front connection type breakers. They are normally installed vertically. However, it is possible to install them horizontally if required. In this case please specify so in your order. (Example) Specify as follows: BZ-N C-R... Installed horizontally, the line positioned on the right side. BZ-N C-L...Installed horizontally, the line positioned on the left side.. s use different size screws for the P-type (Plug-in) breakers type Handle Mounting Mass type screw (kg) Install the door hinge in the shaded area. SA00C, SA00RC BZ-NC M x.9 SA00CUL, SA00RCUL EA00C H00B, H00R SA0RC, SA00RC BZ-N70C M x.9 SA0RCUL SA00RCUL EA0C, EA00C H0B, H00B H0R, H00R 0/7

122 Molded Case Circuit s External accessories N type operating handles Dimensions, mm N-A, N-A (Dust proof packing: BZ-NPB, optional) Panel thickness. to. B B Door panel cutting N-A, A of handle Decorative plate of mounting hole ø Approx.. Door Latch 00 ø Auxiliary handle A± Packing(Optional) -ø Door Hinge type Handle Outline dimensions Mounting Mass type A B screw (kg) SA0HA N-A 7 7. M x. SAH, 0H N-A 9 M x. Notes:. "B" indicates the maximum dimensions of the N type handle fitting plate or the molded case of breaker.. The N type handles are used with front mounting front connection type breakers. They are normally installed vertically. However, it is possible to install them horizontally if required. In this case please specify so in your order. (Example) Specify as follows: N- A-R... Installed horizontally, the line positioned on the right side. N- A-L... Installed horizontally, the line positioned on the left side.. s use different size screws for the X-type (rear connection) or P-type (Plug-in) breakers min. BZ-NB (Dust proof packing: BZ-NP-, optional) Door panel cutting Line max.. Decorative plate Panel Panel thickness. to. Mounting screw -ø of handle Load Lock lever ± Packing(Optional) 7 ø90 of panel cutting Install the door hinge in the shaded area. 0 Mass: 0.kg Dimensions for refernce only. Confirm before construction begins. 0/

123 Molded Case Circuit s External accessories V type operating handles V type operating handles, up to AF Fig. Fig. Operating instructions. MCCB operation Close the door and turn the handle to the ON position and the breaker will be positioned at ON. When the breaker is interrupted automatically the handle will move to the TRIP position. To reset move the handle to the RESET position.. Door panel locking Turn the handle to the RESET position and the lock mechanism will be released thus allowing the door to be opened. The door cannot be opened when the breaker is positioned at ON. Terminal cover Fig. Padlock (Not supplied) Fig. Lock plate. Handle locking The padlock can lock the handle in the OFF position. Locking MCCB with the door open : Fig. Locking MCCB with the door closed : Fig. Pull out the lock plate and hook the padlock.. Interlock release This type is provided with an interlock release screw. Turn this screw if it is necessary to open the door in the ON position. This release the lock and allows the door to be opened. When reclosing the door, make sure the handle of the breaker coincides with the position (ON or OFF) of the external handle position. Fig. 0 Installation BZVC to -VC. Drilling and cutting of the door panel Drill and cut the door panel as shown in the drawing.. Mounting of the MCCB The distance between the backside of the door panel and breaker mounting plate should be the dimension "H" shown in the drawing below. H dimensions, mm (Fig.) BZVC, BZ-V0C: (7 for LAB) BZV0C, BZ-V0C: BZV0C, BZ-V0C: BZ-VC:. Mounting the driving unit Set the breaker handle to the OFF position. Assemble the driving unit so that the breaker handle engages the V handle arm. (Fig.) Secure the driving unit and breaker together to the mounting plate by tightening the four attached mounting screws. (Fig.). Mounting the handle unit Put the handle unit, cover holder, packing, and retainer in front of and behind the panel and tighten the screws temporarily as shown in Fig.. Adjust the position of the handle unit so that it does not tilt against the breaker. (Fig.7) Put the handle of the handle unit in the OFF position and close the door. Check that the shaft engages the latch when the door closes. (Fig.) For VC to V0C For V0C Fig. Fig. 7 Latch Mounting screw Handle unit Interlock-release screw Packing Cover holder Fig. Latch Driving unit Retainer Door panel Shaft 0/9

124 Molded Case Circuit s External accessories V type operating handles Dimensions, mm BZVC, V0C, V0C Door panel B Door panel cutting -ø Handle Handle Handle ø90 7 Panel thickness.-. H 7 BZ-V0C, V0C, V0V, VC Door panel B Optional shaft BZ-VS X = H - 9 Door hinge installation area OP O FT R O R E Handle X 0 0. Panel thickness.-. H The distance between the handle and breaker can be shortened by cutting the optional shaft. Install the door hinge in the shaded area. type S series E series L, H series Handle type Standard type H With the optional shaft (X=) H Area in which the hinge with H can be installed B Mounting screw Mass (kg) SA0C SAC SARC SAC SARC SARCUL EA0AC EAAC EAC EAC EAAC EAC EACUL BZVC to M x 0 0. SAB EAB LAB BZ-V0C 7 7 to 7 M x 0.7 SAC SARC SACUL SARCUL BZV0C to M x 0.7 HBA HBA BZ-V0C to M x 0.7 SAC SARC SACUL SARCUL EAC BZV0C to M x 0.7 HBA BZ-V0C to M x 0.7 HR HR BZ-VC 9 to 9 99 M x 0.7 Notes: Handle protection degree IP (IEC9, JIS C 090) The handle cannot hold the door. 0/

125 Molded Case Circuit s External accessories V type operating handles V type operating handles, 00AF to 00AF Operating instructions. MCCB operation Close the door and turn the handle to the ON position and the MCCB will be positioned at ON. When the MCCB is interrupted automatically the handle will move to the TRIP position. To reset move the handle to the RESET position.. Door panel locking Turn the handle to the RESET position and the lock mechanism will be released thus allowing the door to be opened. The door cannot be opened when the breaker is positioned at ON.. Handle locking The padlock can lock the handle in the OFF position. Locking MCCB with the door open: Fig. Locking MCCB with the door closed: FIg.. Interlock release This type is provided with an interlock release screw. Turn this screw if it is necessary to open the door at the ON position. This releases the lock and allows the door to be opened. When reclosing the door, make sure the handle of the breaker coincides with the position (ON or OFF) of the external handle position. Fig. Fig. Fig. Installation BZVC, V70C. Drilling and cutting of the door panel Drill and cut the door panel as shown in the drawing.. Mounting of the MCCB The distance between the backside of the door panel and MCCB mounting plate should be the dimension as shown in Fig... Mounting the driving unit Set the MCCB handle to the OFF position. Assemble the driving unit so that the MCCB handle engages the V handle arm. (Fig. ) Secure the driving unit and MCCB together to the mounting plate by tightening the four attached mounting screws. (Fig. ). Mounting the handle unit Put the handle unit, packing and retainer in front of and behind the door panel and tighten the screws temporarily as shown in Fig.. Adjust the position of the handle unit so that it does not tilt against the MCCB. (Fig. 7) Put the handle of the handle unit at OFF position and check the latch engages the keeper and close the door while holding the handle unit cover by hand. Final tightening the screws should be performed as keep the engaging position. (Fig. ) Fig. Fig. 0 Fig. Fig. 7 Type number nomenclature BZV C Mounting Blank: Front mounting, front connection X: Front mounting, rear connection P: Plug-in mounting Fig. Basic type BZV C BZ-V C Note: To order a V handle for front-mounting rear connection breakers, add -X to the type number; for plug-in mounting breakers, add -P to the type number. Fuji Electric FA components & Systems Co., Ltd./D & C Catalog 0/

126 Molded Case Circuit s External accessories V type operating handles Dimnsions, mm BZVC, V70C, BZ-VC, V70C Line Door panel cutting Optional shaft ( BZ-VS) Decorative plate Panel -ø Handle 7 7 O F F RESET OPEN I T R P O N RELEASE and handle ø x Load Lock plate Mounting screw H The distance between the handle and breaker can be shortened by cutting the optional shaft. ( X = H -. ) Door hinge installation area Panel thickness. to. 0 Install the door hinge in the shaded area. 00 S series E series H series Handle type Standard type H With the optional shaft H Area in which the hinge with H can be installed Mass (kg) SA00C SA00RC SA00CUL SA00RCUL EA00C BZVC 90± ± 0 to. H00B H00R BZ-VC. SA0RC SA0RCUL SA00RC SA00RCUL EA0C EA00C BZV70C. H0B H0R H00B H00R BZ-V70C. Notes: Handle protection degree IP (IEC9, JIS C090). The handle cannot hold the door. s use different size screws for the X type (rear connection) or P-type (Pulg-in) breakers. 0/

127 Molded Case Circuit s External accessories G type operating handles G type operating handles Operating instructions. MCCB operation Close the door and turn the handle to the ON position and the breaker will be positioned at ON. When the breaker is interrupted automatically the handle will move to the TRIP position. To reset move the handle to the RESET position.. Door panel locking Turn the handle to the OPEN position and the lock mechanism will be released thus allowing the door to be opened. The door cannot be opened when the breaker is positioned at ON.. Handle locking The cylinder key can lock the handle in either the ON or OFF position. Even if it is locked at the ON position when the breaker trips, the handle will indicate TRIP. Installation BZG C. Drilling and cutting of the door panel Drill and cut the door panel as shown in the drawing.. Mounting of the MCCB The distance between the backside of the door panel and breaker mounting plate should be the dimension "A" as shown in the drawing below. Panel Thickness. to. B A± Mounting plate B dimensions, mm BZ-GB: BZ-GB:9 BZ-G70B:9 A dimensions, mm BZ-GB : BZ-GB, G70B: 7 Mount the breaker and the retaining plate commonly to the panel board. Retaining plate G-A, A. Drilling and cutting of the door panel Drill and cut the panel as shown in the drawing.. Mounting of the MCCB When mounting the MCCB to the panel board make sure that the retaining plate and the supporter (type H- separately sold) engage correctly.. Fitting the G type handle (Refer to the illustration.) First remove the set screw and handle mounting screws. Then remove handle, decorative plate and operating mechanism 7. Fit the decorative plate and handle mechanism 7 to the panel by means of the mounting screws as shown in the illustration. Insert the handle on the shaft and secure by means of the set screw. Adjust the height of the retaining plate (H-) by means of the adjusting screws. O C K L Locked O C K L Unlocked. Check the door for play. Carry out the retaining plate adjustment once more taking up any endplay. 0. Interlock release This type is provided with an interlock release screw. Turn this screw if it is necessary to open the door at the ON position. This releases the lock and allows the door to be opened. When reclosing the door make sure the handle of the breaker coincides with the position (ON or OFF) of that of the external handle. Mounting screw Decorative legend plate OFF TRIP Adjusting screw. Fit the decorative plate and handle mechanism to the door panel by means of the mounting screws as shown in the illustration. Handle Lock lever Handle mechanism Mounting screw ON TRIP OFF Handle Reset open Release Set screw Decorative legend plate Type number nomenclature ON Door panel BZG CK Key Blank: Without key K: With cylinder key Q: With padlocking device Basic type BZ-G C G- A. Adjust the height of the retaining plate by means of adjusting screws. Shaft Release screw Door panel 7 Handle mechanism Fuji Electric FA components & Systems Co., Ltd./D & C Catalog 0/

128 Molded Case Circuit s External accessories G type operating handles Dimensions, mm BZ-GC, BZ-GC C/L max. 9 max. 9 Line side Load side C/L. OFF TRIP O/ 9 (7) max. OPEN max 0 9 Lock lever OPEN Panel Thickness Handle lock plate for padlock -ø 7 C/L of handle 7 ø90 ( ): BZ-GC (A) A Thickness. Retaining plate (Provided) type SAR SA0R Handle type BZ-GC, BZ-GC-K BZ-GC, BZ-GC-K A (A) ± () ± (7.) Mass (kg). G-A Line side 7 ON A Door panel drilling -ø. 9 0 ø9 0 Panel drilling E± 7 9 ø G of breaker Load side Interlock release screw OPEN. max..7±0. Retaining plate 0 ON or OFF Door 0 C± 0 OPEN D± B OFF (D+.)± 9 F H mounting hole of handle type SA0HA Handle type G-A, G-A-K Dimensions for reference only. Confirm before construction begins. A B C D E F G H Retaining plate 0 M or ø7 H- SAH SA0H G-A, G-A-K M or ø7 H- 0/

129 Molded Case Circuit s External accessories G type operating handles Dimensions, mm Retaining plate and supporter (Sold separately) H- H mounting hole -ø 7 to Adjustable height... mounting hole -ø7 7 to 0 Adjustable height 0 0/

130 Molded Case Circuit s External accessories Steel enclosures Pressed steel enclosures Description BZ-type enclosures are available in three types two with V and G-type handle which allows the operation from the outside and other with the operating handle of the breaker extending from it to allow it to be directly switched ON or OFF from outside the enclosure. Enclosures with V and G-type handles are provided with a door interlocking mechanism which prevents the door from being opened in the ON condition. Knockout holes for wiring use are provided as shown in the diagram. (For G-type handles, contact FUJI.) Standard AF90-70 Dustproof AF9-7 Rainproof CP97- Type of enclosures type Enclosure S series E series H series Standard With V type handle Dustproof * Rainproof * * SAC, SAC, SARC SAC, SARC EAAC, EAAC EAC, EAC BZCC BZCVC BZCWC SAC, SAC, SARC SAC, SARC EAAC, EAAC EAC, EAC BZCC BZCVC BZCWC EAC BZCC BZCVC BZCWC EAC EAAC BZCC BZCVC BZCWC SAC BZC0C BZ-CV0C BZ-CW0C SARC SAC, SARC BZC0C BZ-CV0C BZ-CW0C HBA, HBA HBA, HBA BZ-C0B- BZ-CV0C BZ-CW0C SA0C, SA0RC SA0C, SA0RC EA0C EA0C H0BA, H0BA BZ-C0B BZ-CV0C BZ-CW0C HR H0R BZ-CB SA0C, SA0RC SA0C, SA0RC EA0C EA0C H0B, H0B H0R BZ-CB BZ-CVC BZ-CWC SARC SA0RC EAC EA0C HB, HR H0B, H0R BZ-C70B BZ-CV70C Notes: Protection degree (IEC9) * : IP0 * : IP * BZ-CV0C and rainproof steel enclosures not available for the H series. Ordering information Specify the following:. Type number of enclosures 0/

131 Molded Case Circuit s External accessories Steel enclosures Dimensions, mm Standard C With V type handle BZCVC to BZ-CV0C A D 7. : BZCVC 0. : BZCVC 9.0 : BZ-CV0C, 0C C D A E B Mounting hole ø7 0 : BZCVC to BZ-CV0C Mounting hole ø7 : BZCVC, BZ-CV0C ø9 : BZCVC to BZ-CV0C -øm lead hole OFF RESET TRIP ON E B 7 : BZCVC, BZ-CV0C, BZ-CV0C -ø lead hole Earth terminal M øm lead hole -øm lead hole H H F G G Earth terminal M BZ-CVC, 70C A D 9 C Connection method diagrams a b c Line Line Load d 0 E B 0 Line -øm lead hole Mounting hole ø -ø lead hole Load -øm lead hole Load Load Line H G Earth terminal M Type BZCC BZCC BZCC BZCC BZC0C, BZ-C0B- BZC0C, BZ-C0B- BZ-C0B BZ-CB BZ-CB BZ-C70B BZ-C BZCVC BZ-CVC BZ-CV0C BZ-CV0C BZ-CVC BZ-CV70C Connection a, b, c a, b, c, d A B C D E F G H M (Ø) Mass (kg) , , 0, 0, 0,, 7,, 7,,,,,, 7, /7

132 Molded Case Circuit s External accessories Terminal covers Terminal covers Description These terminal covers are used as guards to prevent accidental touch with live line terminations. These terminal covers can be fitted to either line or load side. Up to AF Short type BZ-TS Snap-on fitting Transparent and black(bzts only), sealing possible Long type BZ-TB Crimp connection use Transparent and black(bztb only), sealing possible 00AF and larger Long type BZ-TB Transparent IEC and CE marking conformed type S series SAC SAC, SARC SAC, SARC SAC SAC, SARC SAC, SARC SAB SAC SARC SAC, SARC SAR SA0C, SA0RC SA0C, SA0RC SA0R SA0C, SA0RC SA0C, SA0RC SARC SA0RC E series EAAC EAC, EAAC EAC EAC EAAC EAC, EAAC EAC EAAC, EAC EAB EA0C EA0C EA0C EA0C EAC EA0C H series HBA, HBA HBA, HBA H0BA H0BA HR, H0R H0B, H0B H0R HB, HR H0B, H0R Terminal cover Short type BZTSC (Black) BZTSHC (Transparent) BZTSC (Black) BZTSHC (Transparent) BZ-TS0B- BZ-TS0B- BZ-TS0B- BZ-TS0B BZ-TSB B B dimension (mm) Short type Mass (g). 9 7 Terminal cover Long type BZTBC (Black) BZTBHC (Transparent) BZTBC (Black) BZTBHC (Transparent) BZ-TB0B- BZ-TB0B- BZ-TB0B- BZ-TBB- BZ-TB0B BZ-TBB- BZ-TBB BZ-TBB BZ-TB70B Long type Packing quantity : pcs. B dimension (mm) Mass (g) UL Listed type S series SARCUL SARCUL SACUL, SARCUL SACUL, SARCUL SA0CUL, SA0RCUL SA0CUL, SA0RCUL SA0CUL, SA0RCUL SA0CUL, SA0RCUL SARCUL SA0RCUL E series EACUL EACUL Terminal cover Short type BZTSCU (Black)* BZTSCU (Black)* BZ-TS0B- BZ-TS0B Mass (g).. Terminal cover Long type BZTBCU (Black) BZTBCU (Black) BZ-TB0B- BZ-TB0B BZ-TBB BZ-TB70B Mass (g) Terminal cover For flat terminal BZ-TL0B- BZ-TL0B Mass (g) Note: * Standard-provided 0/

133 Molded Case Circuit s External accessories Insulation barriers Insulation barriers Description The interphase barriers are provided on frame size of 0AF to AF breakers for front mounting. The barriers are installed in the molded slots between terminals. The earth barrier is used to increase the insulation with the mounting plate surface when two crimp terminals are wired. Installation of these barriers after wiring is possible even when an external accessory is installed. Interphase barrier Earth barrier Interphase barrier type S series SAC SAC, RC SAC, RC SAC SAC, RC SAC, RC SAC, RC, CUL, RCUL SAC, RC, CUL, RCUL SACUL, CUL SARCUL, RCUL SA0C, 0RC SA0C, 0RC SA0CUL, 0CUL SA0RCUL, 0RCUL SA0C, 0RC, 0CUL, 0RCUL SA0C, 0RC, 0CUL, 0RCUL SARC, RCUL SA0RC, 0RCUL S, SA0H SAH, 0H E series EAAC EAAC, C EAC EAC EAAC EAAC, C EAC EAAC, C EA0C EA0C EA0C EA0C EAC EA0C L and H series LAB(Line* ) HBA, BA HBA, BA H0BA H0BA HR H0R H0B H0B, 0R HB, R H0B, 0R Interphase barrier Type Dimensions, mm A B BZBC 9 BZ-B0B BZB0CU BZ-B0B BZB0CU BZ-BB B-A B-A Packing quantity Mass (g) 9 9 Interphase barrier B A 0 Earth barrier type S series SAC SAC, RC SAC, RC SAC SAC, RC SAC, RC SAC SARC SAC, RC SA0C, 0RC SA0C, 0RC E series EAAC EAAC, C EAC EAC EAAC EAAC, C EAC EAAC, C EA0C EA0C L and H series LAB HBA, BA HBA, BA H0BA H0BA HR H0R Earth barrier Type BZBLC BZBLC BZ-BL0B- BZ-BL0B- BZ-BLB BZ-BL0B BZ-BLB Dimensions, mm* A B (, 7) (0) (7, ) (7, ) (, 0) (90, ) Notes: * Barrier type for the load side is BZ-BB. Interphase barriers are standard provided for the front mounting type breaker. -pole types are available for interphase barrier only, and -sets are required. * The value in parentheses is the dimensions after the barrier is cut. 90 (, 7) 90 (, 7) (0) 70 (0) 70 (0) 70 (0) (, 7) (, 7) Packing quantity Mass (g) 0 Earth barrier A B 0/9

134 Molded Case Circuit s Accessories Mounting modification kits Mounting modification kits Standard type breakers are front mounting front connections. The standard breaker can easily be modified to become front mounting rear connection and flush mounting types by using the modification kits. For front mounting, rear connection (X type) type Kit type For -pole For -pole SA0C, C, RC BZXC BZXC EA0AC, AC, C SAC, RC BZXC BZXC EAC,AC, C SAC, RC BZ-X0C- BZ-X0C- SARC BZ-XC- SAC, RC BZ-X0B- BZ-X0B- EAC HBA SA00C, 00RC BZ-XB-00 BZ-XB-00 EA00C HBA, BA BZ-XC- BZ-X0C- HR, R BZ-XB- H00B, 00R BZ-XB-00 BZ-XB-00 Note: BZXC for EAC/, BZXC for EAC/ Modification kits For front mounting, front connection (Flat terminal) type Kit type For -pole For -pole SA0C, C, RC BZSC BZSC EA0AC, AC, C SAC, RC BZSC BZSC EAC,AC, C LAB BZ-S0B- SAC, RC BZ-SB- BZ-SB- SAC, RC BZ-SB- BZ-SB- EAC HBA, BA BZ-SB- BZ-SB- HBA BZ-SB- BZ-SB- HR, R BZ-SB- Note: BZSC for EAC/, BZSC for EAC/ UL Listed / Flat terminal type Kit type SARCUL BZ-SU0B EACUL SACUL SARCUL SACUL SARCUL SA00CUL SA00RCUL SA0RCUL SA00RCUL BZ-SUB BZSUB BZSUB BZ-SUB BZ-SU70B-0 BZ-SU70B-00 For flush mounting, rear connection (E type) type Kit type For -pole For -pole SA0C, C, RC BZEC BZEC EA0AC, AC, C SAC, RC BZEC BZEC EAC,AC, C SAC BZE0C BZE0C SARC BZEC SARC BZE0C SAC, RC BZE0B BZE0B EAC HBA, BA BZ-EC- BZ-E0C- HBA BZ-E0B- BZ-E0B- HR, R BZ-EB- SA00C, 00RC BZ-EB-00 BZ-EB-00 EA00C H00B, 00R For flush mounting, top and buttom connection (Y type) type Kit type For -pole For -pole SA0C, C, RC BZYC BZYC EA0AC, AC, C SAC, RC BZYC BZYC EAC, AC, C Black terminal: See page 0/9 "Quick reference guide" 0/

135 Molded Case Circuit s Accessories Mounting modification kits and padlocking device Mass For front mounting, front connection Kit type Mass (kg) For front mounting, rear connection (X type) Kit type Mass (kg) For flush mounting, rear connection (E type) Kit type (g) Mass (kg) BZSC 0. BZSC 0. BZSC 0. BZSC 0. BZ-S0B- 0. BZ-SB- 0. BZ-SB- 0. BZ-SB- 0. BZ-SB- 0. BZXC 0. BZXC 0. BZXC 0.0 BZXC 0. BZ-X0C- 0. BZ-X0C- 0. BZ-XC- 0.9 BZ-X0B- 0. BZ-X0B BZ-XB- 0.0 BZ-XB-00.9 BZ-XB-00.7 BZEC 0. BZEC 0.9 BZEC 0. BZEC 0.9 BZE0C 0.9 BZE0C. BZEC.0 BZE0B.7 BZE0B. BZ-EC- 0. BZ-E0C-. BZ-E0B BZ-E0B-. BZ-EB-.7 BZ-EB-00.0 BZ-EB Padlocking device (UL not approved) handles can be fitted with locks. The handle can be locked at either the ON or OFF position. If an overcurrent flows, the breaker trips even when the handle is kept locking. Add the suffix Q or Q to the ELCB type number to order the padlocking device (not sold separately). Q : Cap type, Q :Plate type Applicable padlocking device S series E series L H series Handle locking covers/0 to AF type Handle locking cover EA0AC, AC, C SA0C, C, RC, RCUL, C, RC EAC, C, AC, CUL SAC, RC, CUL, RCUL SAC, RC, CUL, RCUL EAC HBA Handle locking cover BZLC BZL0C BZL0C SA0C EA0AAB SAC EAC SARC EAAC HBA SAC EAC SARC EAC HBA SAC SARC EAC HBA SAC SARC EA00C H00B SA00C EA0C H00R SA00RC EA00C H0B SA0RC H0R SA00RC H00B H00R Cap type Q*(00 to 00AF) Plate type Q A padlock is not provided. 0/

136 Molded Case Circuit s Distribution breakers F series Distribution breakers: F series Features This breaker is used for protection of lighting and heating branch circuits. Compact and light in weight Large breaking capacity ampere frame Ampere rating -pole 0 volts AC Type -pole 0 volts AC Type -pole 0 volts AC Type FB/ FB/0 FB/0 FB/0 FB/ FB/ FB/0 FB/0 FB/0 FB/ FB/ FB/0 FB/0 FB/0 FB/ 7 FB/ FB/7 FB/ FB/ FB/7 FB/ AF9-7 AF9- AF9- FB FB FB Ordering information Specify the following:. Type number Type number nomenclature F B / Ampere rating (A) No. of poles Ampere frame : A : A Basic type breaking capacities Type Shortcircuit breaking capacity (ka) Mass (kg) JIS C70 BS V AC 0V AC /0V AC V AC 0/V AC 0V AC Distribution breaker FB FB FB. 0. FB.. 0. FB.. 0. Characteristic curves Dimensions, mm FB Min Operating time Sec Max. value 0. Min. value (0 to A) 0. (, 0A) Min. value 0.0 (0 to A) FB Min Operating time Sec Min. value Multiple of rated current Max. value Max. value (, 0A) Multiple of rated current Rated current correction ratio (%) Rated current correction ratio (%) Reference temp. 0 C Ambient temperature ( C) Reference temp. 0 C Ambient temperature ( C) 0 FB (FB) 0(FB) 7 ON side OFF side.. FB, FB M or ø Panel drilling M x 7 M x 7 FB (FB) 0(FB). 7 to 9. M x M x 7 FB FB, FB 7 7 ON OFF /

137 Molded Case Circuit s Solid-state trip types Solid-state trip types, SA0E, E, E Features Equipped with a load current pre-trip alarm Constantly monitors the load current, and outputs an alarm when the set current is exceeded. Adjustable rated current The rated current is easy to vary in to steps using an adjustment dial. Wide-range-adjustable trip characteristics The current and time for instantaneous tripping and short-/ long-time delay tripping can be set by the user. Adjustable ground fault tripping determinate and set a current level for ground fault detection in the ranging between % to 0% of the rated CT current. SA E KKD0- Type number nomenclature SAE / X M WF K F=AC00V I I=ACV Basic type Rated current Mounting and connection Blank: Front mounting, front counection X: Front mounting, rear counection E: Flush mounting, rear counection P: Plug-in mounting D: Draw-out Operating device Blank: Manual operation M: Motor operating Internal accessory W: Auxiliary switch K: Alarm switch F: Shunt trip R: Undervoltage trip Control voltage for protection function I= : Adjustable pre-alarm U= : Adjustable ground fault current trip Rated voltage Allowable voltage to V AC to V 00 to 0V AC 70 to V Protection function Adjustable pre-alarm Adjustable ground fault current trip Operating voltage for accessory F= : Shunt trip device R= : Undervoltage trip device M= : Motor operating mechanism 0 Ordering information Specify the following:.type number Fuji Electric FA components & Systems Co., Ltd./D & C Catalog 0/

Series. Technical innovation in compact breakers Standard models that fully conform to international standards

Series. Technical innovation in compact breakers Standard models that fully conform to international standards Series EEH 0 The highest priority for the molded case circuit breakers (MCCBs) and earth leakage circuit breakers (ELCBs) employed in power distribution control systems is to provide sure, safe protection

More information

Molded Case Circuit Breakers H series General information

Molded Case Circuit Breakers H series General information General information Description Models with high breaking capacities Line protection : 15 to 800A Motor protection : 16 to 5A Molded case color : Black Type number nomenclature Series H: H 5 BA / E Q M

More information

CIRCUIT PROTECTORS LOW VOLTAGE FUSES AIR CIRCUIT BREAKERS

CIRCUIT PROTECTORS LOW VOLTAGE FUSES AIR CIRCUIT BREAKERS CIRCUIT PROTECTORS LOW VOLTAGE FUSES AIR CIRCUIT BREAKERS Circuit protectors Circuit protectors Air circuit breakers Air circuit breakers AFaC and BaC types HRC fuses BLC, CR and CS types Super Rapid Fuses

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

Motor Circuit Breakers C4

Motor Circuit Breakers C4 Motor protection rating up to 100 Amps Short circuit breaking capacity up to 100kA Phase failure protection DIN rail mounting Wide range of accessories Options and ordering codes Model C4/32T Setting Short

More information

Earth Leakage Circuit Breakers Accessories

Earth Leakage Circuit Breakers Accessories OFF OFF Earth Leakage Circuit s Accessories Variation of external accessory Insulation barriers The interphase barrier reinforces the insulation between terminals, while the earth barrier increases the

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

Protectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x.

Protectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x. Types MS116, MS132, MS5x, MS9x are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/OFF control, and protection against short circuit,

More information

Circuit Protectors CP31F, 32F, 33F

Circuit Protectors CP31F, 32F, 33F CP3F, 32F, 33F CP-F slim type circuit protectors 20V AC/6V DC (-pole) 0.A to 30A 20V AC/2V DC (2-pole) 0.A to 30A 20V AC (3-pole) 0.A to 30A Description FUJI's compact and high-performance CP-F series

More information

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

Protection components

Protection components Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed

More information

Molded Case Circuit Breakers Solid-state trip types

Molded Case Circuit Breakers Solid-state trip types Solidstate trip types Solidstate trip types, SA00E, 0E, 00E Features Equipped with a load current pretrip alarm Constantly monitors the load current, and outputs an alarm when the set current is exceeded.

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and

More information

VL Circuit Breaker Features & Benefits. powerful ideas RELIABLE SOLUTIONS

VL Circuit Breaker Features & Benefits. powerful ideas RELIABLE SOLUTIONS VL Circuit Breaker Features & Benefits powerful ideas RELIABLE SOLUTIONS A Solutions Oriented Circuit Protection Family The Tangram An ancient Chinese game in which a few simple components provide endless

More information

UMBW-UL489 and UL1077 Listed

UMBW-UL489 and UL1077 Listed -UL489 and UL77 Listed Introducing the New WEG Series Thermal-Magnetic Miniature Breakers. This new offering includes both UL489 and UL77 approvals to provide a solution for circuit & equipment protection

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

Protection Equipment. 5/2 Introduction

Protection Equipment. 5/2 Introduction Protection Equipment /2 Introduction SIRIUS 3RV2 Motor Starter Protectors/ Circuit Breakers up to 40 A /6 General data /12 For motor protection /14 For motor protection with overload relay function /1

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

3VF3 to 3VF8 Circuit-Breakers

3VF3 to 3VF8 Circuit-Breakers 3VF3 to 3VF8 Circuit-Breakers Accessories Operating mechanisms For other s for 3VF3 with knob Rotary drive, complete, scope of supply Cubicle door for 3VF6 Motor operating mechanism for 3VF3 Motor operating

More information

ACS motor protection circuit breakers KT 7 Introduction

ACS motor protection circuit breakers KT 7 Introduction Introduction Automatic Type 2 coordination The right circuit breaker for all applications The KT 7 circuit breaker family consists of two basic frame sizes of mm and 5 mm in three variations with different

More information

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101 IEC CONTACTORS Description: RT01 Contactors Are Available With Cage Clamps On The Main Terminal Connections As Well As The Auxiliary Terminal Connections. RT02, RT0 and RT04 Contactors Are Available With

More information

IEC Power Control SIRIUS. Motor Starter Protectors. Revised 04/20/15. Section Overview... 1/2-1/3. Motor Starter Protectors

IEC Power Control SIRIUS. Motor Starter Protectors. Revised 04/20/15. Section Overview... 1/2-1/3. Motor Starter Protectors 04/20/15 IEC Power Control Motor Starter Protectors Contents Pages Section Overview......................... 1/2-1/3 Motor Starter Protectors 3RV20 MSP, Class 10/20.................... 1/4-1/5 3RV10 MSP,

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

SD Series Non-Fused Load Switches

SD Series Non-Fused Load Switches SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load

More information

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application. Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80

More information

XT IEC Power Control Manual Motor Protectors

XT IEC Power Control Manual Motor Protectors May 07 Product Selection Table 7. Rotary with Screw Terminals Global Ratings and North American Ratings Type and Type 2 Coordination Motor Protective Device with Thermal and Magnetic Trip Rated Uninterrupted

More information

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4. Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

Protection Equipment

Protection Equipment Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

Product index. 4 - Manual motor protectors. Phone: Fax: Web:  - Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427 Data sheet CI-TI TM Contactors and Motor Starters Circuit Breakers November 2002 DKACT.PD.C00.L2.02 520B1427 Introduction Circuit breakers/manual motor starters cover the power ranges 0.09-12.5 kw This

More information

General data 5/37. Overview

General data 5/37. Overview General data Overview Benefits High short-circuit breaking capacity in the feeder Optimum usability in motor feeders for the special voltages 440 V, 480 V, 0 V and 690 V Compact design The are available

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

MS General Information Extended Product Type: MS

MS General Information Extended Product Type: MS MS132-1.6 General Information Extended Product Type: MS132-1.6 Product ID: 1SAM350000R1006 EAN: 4013614400063 Catalog Description: MS132-1.6 Manual Motor Starter Long Description: The MS132-1.6 manual

More information

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004 PRICING October 2004 Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products Class 600 CONTENTS Description Page Multi 9 Supplementary Protectors and Miniature Circuit Breakers.............3

More information

Miniature Circuit Breakers

Miniature Circuit Breakers S00 Series Miniature S00 Series Miniature Circuit Breakers Description The S00 Series miniature circuit breaker offers a compact solution for protection requirements. The S00 devices are UL tested limiting

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

Low voltage circuit breakers

Low voltage circuit breakers Super Solution North American Edition Low voltage circuit breakers Contents Overview Main characteristics Accessories Technical information Mounting & connection Characteristics curves Dimensions A-1 A-2

More information

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866) .4 Miniature Circuit Breakers and Supplementary Protectors SPHM Supplementary Protector SPHM Supplementary Protector Product Description The SPHM Supplementary Protector is a dual rated product for both

More information

Mitsubishi Breaker Line-up

Mitsubishi Breaker Line-up Mitsubishi Breaker Line-up MCB DIN Series MCCB WS-V Series MCCB WS Series ACB AE-SW Series CP DIN Series December 4 th, 2015 Mitsubishi Electric Corp. Fukuyama Works Page 1 Agenda 1 2 3 LVS Product Overview

More information

2.2. Molded Case Circuit Breakers. Contents. NG-Frame ( Amperes) Series G

2.2. Molded Case Circuit Breakers. Contents. NG-Frame ( Amperes) Series G . NG-Frame (00 ) NG-Frame (30 00 s) Product All Eaton NG-Frame circuit breakers are suitable for reverse feed use All NG-Frame circuit breakers are HACR rated Contents Page EG-Frame (5 5 s)..................

More information

Motor Starter Protectors

Motor Starter Protectors Motor Starter Protectors Industrial Controls Product Catalog 207 Section contents Section Overview /2 - /3 Motor Starter Protectors 3RV20 MSP, Class 0/20 /4 - /5 Circuit Breakers 3RV27, 3RV28 Circuit Breaker

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

Motor Starter Protectors

Motor Starter Protectors Motor Starter Protectors Industrial Controls Product Catalog 09 Section contents Section Overview / - /3 Motor Starter Protectors 3RV0 MSP, Class 0/0 /4 - / Circuit Breakers 3RV7, 3RV8 Circuit Breaker

More information

Power Break II Switchboard

Power Break II Switchboard Power Break II Switchboard Now available with PowerBreak II Circuit Breakers through 4000A GE s Power Break II Switchboard is now available with the new Power Break II Insulated Case Circuit Breaker (800A

More information

KT4 Manual Motor Starter

KT4 Manual Motor Starter KT4 Manual Motor Starter Ideal for use as a manual starter The KT4 is a manual motor starter that employs the features of power switching, thermal overload protection and control circuit signaling in one

More information

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Medium Voltage Switch MVS Product Description............................................. 2 Application Description..........................................

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

Air-insulated switchgear UniGear type ZS1

Air-insulated switchgear UniGear type ZS1 Air-insulated switchgear UniGear type ZS1 ABB Power Technologies / 1-7074 D 12-03-2003 - Air-insulated switchgear UniGear type ZS1 ABB Power Technologies / 2-7075 D 1 2-03-2003 - Rated voltage kv 12 17.5

More information

Interruption Technology of Breakers for High-voltage Direct Current

Interruption Technology of Breakers for High-voltage Direct Current Interruption Technology of Breakers for High-voltage Direct MORIAI Hiroshi ABSTRT Applications for direct current () electric distribution have been spreading along with the increase of data centers and

More information

ACW Molded-Case Circuit Breaker UL 489 Listed

ACW Molded-Case Circuit Breaker UL 489 Listed Motors Automation Energy Transmission & Distribution Coatings Molded-Case Circuit Breaker UL 489 Listed Overview Introducing the WEG Series of Molded Case Circuit Breakers now available with UL489 certification.

More information

Power systems Protection course

Power systems Protection course Al-Balqa Applied University Power systems Protection course Department of Electrical Energy Engineering Dr.Audih 1 Part 3 Protective Devices Fuses & Circuit Breakers 2 Introduction: Fuse Is advice used

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

PowerPact B. Molded case circuit breakers and switches from A

PowerPact B. Molded case circuit breakers and switches from A PowerPact B Molded case circuit breakers and switches from 15-125 A 2 schneider-electric.us Efficiency that clicks. PowerPact B molded case circuit breakers Schneider Electric introduces a new family member

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information

INDIVIDUAL CATALOG08 from D&C CATALOG 20th Edition

INDIVIDUAL CATALOG08 from D&C CATALOG 20th Edition CP-F type Circuit protectors CP-P type Circuit protectors CP-B type Circuit protectors CIRCUIT PROTECTORS CP-V type Circuit protectors LOW VOLTAGE CURRENT - LIMITING FUSES AFaC and BaC types HRC fuses

More information

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence

ACW. Molded-Case Circuit Breaker UL 489 Listed. ACW Catalog Number Sequence rotection rotectors Contactors Overloads Relays ushbuttons Molded-Case Breaker UL 489 Listed The EG Series of Molded Case Breakers are designed to provide overload and short-circuit protection for industrial

More information

Bulletin 190-M Compact Starters. Selection Guide

Bulletin 190-M Compact Starters. Selection Guide Bulletin 190-M Selection Guide Bulletin 190-M Selection Guide 3 Bulletin 190-M Compact Design to 45mm Wide Common Adapter for Panel or DIN Rail Mounting Pre-Wired Assembly All Control Terminations Located

More information

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches Medium Voltage Metal-Enclosed Switches Outdoor Medium Voltage Switch.1 Introduction Product Selection Guide....................................2 Medium Voltage Switch MVS Product Description......................................

More information

Molded Case Circuit Breaker

Molded Case Circuit Breaker & The Ultimate Safety Breaker Molded Case Circuit Breaker www.terasaki.co.jp Catalogue No. 13!5E ! Safety Notice Carefully read instruction manual to ensure proper installation, connection, operation,

More information

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MANUFACTURED IN THE EU EUROPEAN QUALITY 1, 2 & 3 POLE MCB s TRIPPING CURVES C & D CURRENT RATINGS 1AMP TO 63AMPS 10KA BREAKING CAPACITY

More information

IEC Standard Compliant Vacuum Circuit-Breaker (12 kv, 24 kv) for Southeast Asian Markets

IEC Standard Compliant Vacuum Circuit-Breaker (12 kv, 24 kv) for Southeast Asian Markets IEC Standard Compliant Vacuum Circuit-Breaker (12 kv, 24 kv) for Southeast Asian Markets OKAZAKI, Takayuki KIKUCHI, Masanori TOKUNAGA, Yoshihide A B S T R A C T As Southeast Asia continues to experience

More information

Multi-Pak Group Control

Multi-Pak Group Control Multi-Pak Grouping.1 Product....................................... Application.................................... Features Enclosures........................................... V-T-2 V-T-2 V-T-2 Feeder

More information

Magnum IEC Low Voltage Air Circuit Breakers

Magnum IEC Low Voltage Air Circuit Breakers Magnum IEC Low Voltage Air Circuit Breakers Product Focus Up to 690 Vac 42 ka to 100 ka Icu 800 to 6300 Amperes EN 60947-2 A Global Source for Innovative Electrical Power Distribution Solutions Proven

More information

Safety, Reliability and Performance verified with the KEMA KEUR mark. Series G Moulded Case Circuit Breakers

Safety, Reliability and Performance verified with the KEMA KEUR mark. Series G Moulded Case Circuit Breakers Series G Moulded Case Circuit Breakers Product Focus Up to 690 Vac 18kA to 100kA Icu 16-2500 Amperes IEC 60947-2 Safety, Reliability and Performance verified with the KEMA KEUR mark Safety, Reliability

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed

More information

Ideal for use as a manual starter

Ideal for use as a manual starter Manual Motor Starter Ideal for use as a manual starter The is a manual motor starter that employs the features of power switching, thermal overload protection and control circuit signaling in one compact

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

Series L9 UL489 Miniature Circuit Breakers

Series L9 UL489 Miniature Circuit Breakers Series L9 UL489 iniature Circuit Breakers Industrial Circuit Breakers for Branch Circuit Protection up to 63 Amps L9 Series B Circuit Breakers Series B L9 UL489 circuit breakers offer new features, expanded

More information

Product Line Overview. The Most Logically Designed Contact Assembly

Product Line Overview. The Most Logically Designed Contact Assembly Circuit Breakers & Supplementary Protectors 15 00 Amperes for UL, CSA & IEC Applications Product Line Overview -3 General Information Cutler-Hammer Series G Molded Case Circuit Breakers provide increased

More information

Series L9 UL-489 Miniature Circuit Breakers

Series L9 UL-489 Miniature Circuit Breakers Series UL-489 iniature Breakers Industrial Breakers for Branch up to 40 Amps Sprecher+Schuh includes a line of circuit breakers approved for branch circuit applications in the United States and Canada

More information

PowerPact Circuit Breakers for Control Panel Disconnects Class 0611

PowerPact Circuit Breakers for Control Panel Disconnects Class 0611 Data Bulletin 0611DB0402 R04/16 05/2016 Replaces 0611DB0401 R11/11 PowerPact Circuit Breakers for Control Panel Disconnects Class 0611 Retain for future use. Introduction Certifications The electrical

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

25.4. Molded Case Circuit Breakers. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents

25.4. Molded Case Circuit Breakers. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents .4 Molded Case Circuit Breakers Gi-, Fi, Ji-, Ki-, Li-Frames Molded Case Circuit Breaker Family Molded Case Circuit Breakers When higher interrupting ratings are not required. Product Overview Gi-, Fi,

More information

Three-phase 200 V series: FRN0025 to 0060C2S-2U Three-phase 400 V series: FRN0013 to 0030C2S-4U

Three-phase 200 V series: FRN0025 to 0060C2S-2U Three-phase 400 V series: FRN0013 to 0030C2S-4U Instruction Manual Supplement for FRN-C2S-2U/4U (7.5 to 20 HP) Compact Inverter 200 V series: FRN0025 to 0060C2S-2U series: FRN0013 to 0030C2S-4U Thank you for purchasing our FRENIC-Mini series of inverters.

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certifi ed for

More information

Moulded Case Circuit Breakers

Moulded Case Circuit Breakers Moulded Case Circuit Breakers DU Series About us Larsen & Toubro is a technologydriven company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field

More information

S&C TripSaver II. Cutout-Mounted Recloser. For enhanced lateral circuit protection at 15 kv and 25 kv

S&C TripSaver II. Cutout-Mounted Recloser. For enhanced lateral circuit protection at 15 kv and 25 kv TripSaver II Cutout-Mounted Recloser For enhanced lateral circuit protection at 15 kv and 25 kv Introducing s new TripSaver II Cutout-Mounted Recloser: A better solution for overhead lateral circuit protection

More information

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control . Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Relays.................... C440/XT Electronic

More information

DPX earth leakage DPX 3 -I earth leakage

DPX earth leakage DPX 3 -I earth leakage 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 250 + earth leakage Reference(s) : 420 225/ 227/ 228/229/ 255/ 257/ 258/ 259/ 285/ 287/ CONTENTS PAGES 1. USE 1 2. RANGE 1 3.

More information

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction Introduction Introduction Schneider Electric offers a complete line of products for the manual control and protection of motors. This catalog covers those devices designed to meet IEC standards for protection

More information

Technical Information

Technical Information Technical Information KT7 Controller Time-Current Characteristic KT7 Manual Motor Starter/Protector 1. Thermal Release Trip Current The adjustable current-dependent delayed bimetal release protects motors

More information

NDM3 Series. Molded Case Circuit Breaker. Shanghai Liangxin Electrical CO., LTD.

NDM3 Series. Molded Case Circuit Breaker. Shanghai Liangxin Electrical CO., LTD. Shanghai Liangxin Electrical CO., LTD. - Liangxin Electrical - All rights reserved Address: No. 66 eng An Road, Pu Dong New District, Shanghai Post code: 07 Tel: 6--479 Fax: 6--5675966 E-mail: client@sh-liangxin.com

More information

UTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB

UTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB PRODUCT CATALOG SELECTION GUIDE UTS400 CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL UL SERIES & FRAME: Susol 400AF PERFORMANCE Rating 80% 0% ka N NT 65 SUFFIX UL : UL 240Vac H HT 0 L

More information

37-SDMS-04 SPECIFICATIONS FOR INTERFACE LOW VOLTAGE MAIN CIRCUIT BREAKERS

37-SDMS-04 SPECIFICATIONS FOR INTERFACE LOW VOLTAGE MAIN CIRCUIT BREAKERS SPECIFICATIONS FOR INTERFACE LOW VOLTAGE MAIN CIRCUIT BREAKERS This specification is property of SEC and subject to change or modification without any notice CONTENTS Clause Page 1.0 SCOPE 3 2.0 CROSS

More information

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories Page 1 of 5 MS132-10 ABB contact for United States of America General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: MS132-10 1SAM350000R1010 4013614400100 MS132-10

More information

Bulletin 1489 Circuit Breakers. Selection Guide

Bulletin 1489 Circuit Breakers. Selection Guide Bulletin 1489 s Selection Guide Bulletin 1489-A Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable

More information

Industry Automation Control Components

Industry Automation Control Components Industry Automation Control Components SIRIUS 3RV2 Motor Starter Protectors SIRIUS 3RV21 Motor Starter Protectors can be easily and flexibly combined with other SIRIUS devices to reduce space requirements

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00, Low-Voltage Controls and Distribution > Industrial Controls > Protection Equipment > Circuit Breakers/Motor Starter Protectors > Motor Starter Protectors SIRIUS RV up to 00 A RV0-0DA5 CIRCUIT-BREAKER,

More information

01 Spectra Plus - Introduction

01 Spectra Plus - Introduction 01 Spectra Plus - Introduction Standard features Conforming to IS13947-2/EN60947 2 Compact dimensions Available in 3P & 4P High performance microprocessor protection release Wide overload setting from

More information

Design Standard. Purpose: Design Standard:

Design Standard. Purpose: Design Standard: Design Standard Purpose: This design standard has the purpose of creating a consistent application of motor-control centers throughout the East Side Union High School District, therefore achieving a standard

More information

Manual Motor Starters

Manual Motor Starters Leader in Electrics & Automation Meta-MEC Manual Motor Starters Electric Equipment LG Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 45 mm 70 mm 63AF 100AF 3 LG Meta-MEC

More information

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised:

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised: File E47705 Vol. 7 Sec. 9 Page 1 Issued: 1997-08-29 and Report Revised: 2005-06-30 DESCRIPTION PRODUCT COVERED: USL, CNL - Type Nos. 3RV1021, 3RV1121, 3RV1321 or 3RV1421, followed by combination of 0,

More information

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw Industrial Generator Set Accessories Line Circuit Breakers 15-2500 kw Standard Features Single Circuit Breaker Kit with Neutral Bus Bar 15-300 kw Model Shown The line circuit breaker interrupts the generator

More information

Motor Protection Circuit Breakers 3VU13 and 3VU16

Motor Protection Circuit Breakers 3VU13 and 3VU16 Motor Protection Circuit Breakers 3VU13 and 3VU16 3VU13/3VU16 is suitable for use in fuseless motor feeders upto 11KW/22KW (25A/63A) respectively. 3VU motor protection circuit breakers are used for protection

More information

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) Catalog Class 734 0734CT0201R1/07 07 CONTENTS Description..............................................Page Description.............................................

More information