Southern Star Central Gas Pipeline Contractor Covered Task List Last updated 8/15/2018
|
|
- Geoffrey Carpenter
- 5 years ago
- Views:
Transcription
1 007 Operate Valves 008 Measurement of Wall Thickness with Ultrasonic Device 018 Inspect Navigable Waterway Crossing (b) 201 Abnormal Operating Conditions Related to Welding on Pipelines Monitoring of Welding Process (a) (c) Visual Inspection of Welds not Non-Destructively Tested (b) (c) 204 Non-Destructive Testing (Dye Penetrant) Non-Destructive Testing (Mag Particle) Non-Destructive Testing (Ultrasonic) Non-Destructive Testing (X-Ray) Plastic Pipe Joining: Butt Fusion Plastic Pipe Joining: Mechanical Joining Plastic Pipe Joining: Electrofusion Joining Oral Oral Oral No 1:0 1 No 1:0 1 No 1: Perform Plastic Fusion Inspection Oral 213 Joining of Metal Pipe and Components by means other than Welding - Threaded and Flanged Connections 214 Joining of Metal Pipe and Components by means other than Welding - Threaded Connections Page 1 Copyright Veriforce, LLC. All rights reserved. Rev. 10
2 215 Joining of Metal Pipe and Components by means other than Welding- Flanged Connections Joining of Metal Pipe - Compression Couplings Small Diameter Metal Tubing and Fitting Installation Install Tracer (electrically conductive) Wire (e) NA 302 Installation of Customer Meters and Service Regulators (Residential and Small Commercial) of Buried Pipelines When Exposed Protection of Coating When Backfilling and From Below Ground Supports (d) (c)(6) ( c ) (b) NA Oral Protection of Coatings From Above Ground Structures (d) 406 Conduct Test to Determine Cathodic Protection Current Requirements (a) (d)(6) 407 Perform Cathodic Protection Survey (a) (e) (e) (d)(6) Oral (a) 408 Inspect Cathodic Protection Rectifier (b) ( c ) 409 Inspect Interference Bonds (c) ( c ) 410 Clear Shorted Casing (c) (b)(1) (a) 411 Inspect/Test to Assure Electrical Isolation is Adequate (d) (d)(6) Install CP Leads on Pipeline Using Exothermic Weld Anode Installation on Submerged Pipeline or Facilities Inspect for Internal Corrosion Whenever Pipe is Removed (b)(1) 415 Monitoring for Internal Corrosion with Probes and Coupons (d)(5) 416 Monitoring for Internal Corrosion with Gas Samples (c) (b) Page 2 Copyright Veriforce, LLC. All rights reserved. Rev. 10
3 417 Atmospheric Corrosion Monitoring General and Localized Corrosion Measurement (Remedial Measures) (a)(b) 419 Cathodic Protection Potential Measurement (a) (d)(8) (b) (a) 420 Soil Resistivity 421 Measurement of Depth of Pitting with Pit Gage Assessment of Pipeline Segments Using Long Range Guided Wave UT 423 Perform Direct Current Voltage Gradient (DCVG) Survey (d)(7) 424 Perform AC Current Attenuation (ACCA) Survey (e) (d)(7) 425 Perform Alternating Current Voltage Gradient (ACVG) Survey (h)(3) (d)(7) 426 Inspect Pipe Coating with Holiday Detector (a) (a) Inspection of Above or Below Ground Coatings Oral 428 Pin Brazing to Install CP Leads on Pipeline Monitoring for corrosion - bacteria testing - serial dilution method (MIC) 435 Measure and Identify Mechanical Damage on Installed Pipe and Components Perform Close Survey (e) (e) (d)(6) & (7) (a) 437 Perform Hot Spot Survey (e) (a) 480 Apply Approved Coating by Hand Application (a) Apply Approved Coatings by Mechanical Spray and Hand Application Methods (a) Apply Approved Coatings by Wrap Application (a) Page 3 Copyright Veriforce, LLC. All rights reserved. Rev. 10
4 501 Conduct a Pressure Test (d) 502 Conduct Pressure Test on Pipe that is to be Operated at a Pressure <100 psig 601 Start-up/Shut-down of Pipeline to Assure Operation Within MAOP / MOP (b) (b)(5) 602 Monitoring Pipeline Pressure (b)(5) Compressor Units: Startup, Operation, Shutdown and Purging Before Returning to Service (b)(7) (b)(6) ( c )(9) Oral 605 Locate Line/Install Temporary Marking of Buried Pipeline (c)(5) (c)(5) 606 Locate and Mark Submerged Pipelines (c)(5) 607 Damage Prevention: Observation of Excavating and Backfilling (c)(6) (b) (c)(6) 608 Damage Prevention for Blasting Near a Pipeline (c)(6) (c)(6) Oral 609 Inspect and Maintain Odorization Equipment (e) 610 Monitor Odorant Concentration (f) 611 Hot Tap (Steel Pipe) Hot Tap (Plastic Pipe) Purge Pipeline Facilities With Gas (a) 614 Purge Pipeline Facilities With Air or Inert Gas (b) (c)(10) Oral 616 Atmospheric Monitoring during Hot Work Operations ( c )(11) 619 Damage Prevention during Vacuum Excavation and Backfilling Activities 661 Launching and/or Receiving Internal Devices (Pigs) (c) (d)(5)(iv ) (d)(9) (c)(6) (c)(6) Oral Page 4 Copyright Veriforce, LLC. All rights reserved. Rev. 10
5 701 Patrolling Pipeline and Leakage Survey without Instrument (d)(4) (a) Oral 702 Leakage Survey with Leak Detection Device Placing/Maintaining Line Markers (a) (c) 704 Permanent Field Repair by Grinding Permanent Field Repair Using Composite Materials (Clockspring) 706 Permanent Field Repair Using Composite Materials (Armor Plate) (a) (a)(2) (a) (a)(2) 707 Permanent Field Repair Using Bolt-On Clamp/Sleeve (a) (a)(2) 708 Permanent Field Repair Using Full Encirclement Weld Sleeve 709 Inspection and Testing of Relief Devices (Compressor Stations, Meter Stations, Regulating Stations) 710 Inspect/Test Compressor Station Remote Shutdown Devices (ESD/EBD) (a)(2) (a) (a) (b) Oral Certificate and Oral Certificate and Oral (c) 711 Inspect, Test, and Maintain Systems (c) (b)(1) (b)(1) 712 Programmable Logic lers (c) (b)(1) (a) 713 Test/Maintain Gas Detection and Alarm Systems (c) 714 Inspect and Maintain Pressure ing and Regulating Devices 715 Test and Maintain Pressure Switches and Transmitters in Pressure ing and Regulating Service (a) (b) (a) (b) 716 Inspect, Maintain, and Operate Valves Monitoring for Internal Corrosion with Liquid Samples (a) (b) Aerial Leakage Survey: Transmission Aerial Leakage Survey: Transmission (UV/IR) Yes 1:3 1 Page 5 Copyright Veriforce, LLC. All rights reserved. Rev. 10
6 762 Line Stopping Utilizing a Hot Tap Fitting Page 6 Copyright Veriforce, LLC. All rights reserved. Rev. 10
Northern Natural Gas Contractor Covered Task List Last updated 4/26/2018
001 Provide Security for Pipeline Facilities 195.436 Oral 003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 Oral
More informationEnLink Midstream Contractor Covered Task List Last updated 11/8/2017
003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 005 Repair Breakout Tank Overfill Protective Devices 195.428
More informationDCP Midstream Contractor Covered Task List Last updated 7/11/2018
001 Provide Security for Pipeline Facilities 195.436 Oral 007 Operate Valves 008 Measurement of Wall Thickness with Ultrasonic Device 009 Movement and/or Relocation of Liquid Pipelines 195.424 011 Inspect,
More informationColumbia Pipeline Group Contractor Covered Task List Last updated 1/8/2018
001 Provide Security for Pipeline Facilities 195.436 Oral 003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 Oral
More informationWilliams Contractor Covered Task List Last updated 11/7/2017
003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 Oral 005 Repair Breakout Tank Overfill Protective Devices 195.428
More informationBoardwalk Pipeline Partners, LP Contractor Covered Task List Last updated 9/17/2018
003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 Oral 005 Repair Breakout Tank Overfill Protective Devices 195.428
More informationDominion Energy Questar Pipeline LLC Contractor Covered Task List Last updated 10/3/2017
007 Operate Valves 008 Measurement of Wall Thickness with Ultrasonic Device 103 Non-destructive Testing (Other than testing of welds) -- Mag Particle 104 Non-destructive Testing (Other than testing of
More informationEnbridge Gas Transmission and Midstream and Enbridge Liquid Pipelines (Express-Platte) Contractor Covered Task List Last updated 8/30/2018
001 Provide Security for Pipeline Facilities 195.436 Oral 003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 Oral
More informationSaddle Butte Rockies Midstream LLC Contractor Covered Task List Last updated 12/6/2017
003 Test Breakout Tank Overfill Protective N/A 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective N/A 195.428 Oral 005 Repair Breakout Tank Overfill Protective N/A 195.428 007 Operate
More informationHoward Midstream Energy Partners LLC Contractor Covered Task List Last updated 10/11/2013
001 Provide Security for Pipeline Facilities 195.436 Oral 003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 005
More informationEpic Consolidated Operations LLC Contractor Covered Task List Last updated 9/6/2018
003 Test Breakout Tank Overfill Protective 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective 195.428 Oral 005 Repair Breakout Tank Overfill Protective 195.428 006 Inspection of Breakout
More informationTransCanada US Contractor Covered Task List Last updated 9/27/2018
003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 Oral 005 Repair Breakout Tank Overfill Protective Devices 195.428
More informationEnergy Transfer Partners LP Contractor Covered Task List Last updated 3/2/2018
001 Provide Security for Pipeline Facilities 195.436 Oral 003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 Oral
More informationEnergy Transfer Partners LP Contractor Covered Task List Last updated 12/10/2018
001 Provide Security for Pipeline Facilities 195.436 Oral 003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 005
More informationNoble Energy Contractor Covered Task List Last updated 2/20/2019
003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 005 Repair Breakout Tank Overfill Protective Devices 195.428
More informationBlack Hills Energy Contractor Covered Task List Last updated 10/10/2018
007 Operate Valves 103 Non-destructive Testing (Other than testing of welds) -- Mag Particle 201 Abnormal Operating Conditions Related to Welding on Pipelines 195.452(h) 192.225 192.227 192.715 192.717
More informationAppendix B Kinder Morgan Operator Qualification Program List of Covered Tasks Hazardous Liquid Pipelines Part 195 revised 8/24/2018
Abnormal Operating Conditions Outside of 101.01 Room Abnormal Operating Conditions Inside of 101.02 Room 102.01 Measure Structure-to-Soil Potentials 102.02 Advanced Cathodic Testing 102.03 Active Corrosion/MIC
More informationAppendix B Kinder Morgan Operator Qualification Program List of Covered Tasks Hazardous Liquid Pipelines Part 195 revised 12/12/2017
Abnormal Operating Conditions Outside of 101.01 Room Abnormal Operating Conditions Inside of 101.02 Room 102.01 Measure Structure-to-Soil Potentials 102.02 Advanced Cathodic Testing 102.03 Active Corrosion/MIC
More informationAppendix A Kinder Morgan Operator Qualification Program List of Covered Tasks - Natural Gas - Part 192 Revised 12/13/2017
01.01.01 Abnormal Operating Conditions (AOC) - Outside of Room 01.01.02 Abnormal Operating Conditions (AOC) - Inside of Room (new task effective 1/1/2018) 02.01.01 Gas Detection & Alarm System Maintenance
More informationASMECourseCatalog.
ASMECourseCatalog www.energyu.org www.midwestenergy.org ASME Abnormal Operating Conditions... 6 ASME GAS01 Hazards of Natural Gas and Prevention of Accidental Ignition... 6 ASME 0001 Measure Structure-to-Electrolyte
More informationFlorida City Gas Contractor Covered Task List
001A Abandonment and deactivation of facilities 192.727 001B 001C 001SUBA Abandonment and deactivation of facilities (service lines not in use) Abandonment and deactivation of facilities (service lines
More informationOperator Qualification (OQ) Report
AOCF 66102/67107 Abnormal Operating Conditions Field for Natural Gas and Hazardous Liquids 5/15/2014 5/15/2017 AOCG 67107 Abnormal Operating Conditions for Natural Gas 5/16/2014 5/16/2017 TM001 66101 02
More informationCOVERED TASK Conduct Cathodic Protection Surveys 1 DESCRIPTION ELEMENTS OF TASK 4 PART QUESTION NOTES ABNORMAL OPERATING CONDITIONS
COVERED Conduct Cathodic Protection Surveys 1 Annual surveys are conducted for each operator s pipeline system that is under cathodic protection to ensure that the protection is adequate. This task is
More informationPIGGING PRODUCTS. Capex supply. PIG LAUNCHER and RECEIVER
PIGGING PRODUCTS Capex supply PIG LAUNCHER and RECEIVER Before Cleaning After Cleaning TYPES OF PIGS DISPLACEMENT AND BATCHING PIGS AND PIG WITH BLADES (FOR CLEANING) 2 to 6 3 and 4 PIG with blades 5 to
More informationPIPELINE CORROSION CONTROL
NCCER 13614 Progress Blvd, Alachua, Florida 32615 Phone: (888) 622-3720 E-mail: info@nccer.org PIPELINE CORROSION CONTROL Competencies / Objectives Level One MODULE 66101-02 INTRODUCTION TO THE PIPELINE
More informationPHMSA Office of Pipeline Safety Dave Mulligan Western Region
PHMSA Office of Pipeline Safety Dave Mulligan Western Region Chevron Pipeline Releases Salt Lake City, Utah June 11, 2010 & December 1, 2011 Dave Mulligan U.S. Department of Transportation (US DOT) Pipeline
More informationPROCEDURE EXTRUDED HOT TAP & LINE STOP TEES DESIGN & MANUFACTURING VALIDATION
6534 Petropark Dr. Houston, TX 77041 USA Tel: +1 713-937-6193 Fax: +1 713-937-8695 www.uni-forge.com PROCEDURE EXTRUDED HOT TAP & LINE STOP TEES DESIGN & MANUFACTURING VALIDATION Prepared by: Approved
More informationNew UST Installation Inspection Checklist
Nebraska State Fire Marshal Fuels Division - FLST Section 246 South 14 TH Street - Lincoln, NE 68508-1804 (402) 471-9466 New UST Installation Inspection Checklist (Petroleum or Hazardous Substances) Inspection
More informationThe Implementation of a Storage Facility Inspection Program. Presented By: John R. Rueckel PCA Engineering, Inc.
The Implementation of a Storage Facility Inspection Program Presented By: John R. Rueckel PCA Engineering, Inc. Storage Facility Inspection Why implement an inspection program? Regulatory Requirements
More informationInspector's Initials: Tank Owner or Agent Signature: Title: Date:
STATE OF TENNESSEE DEPARTMENT OF ENVIRONMENT AND CONSERVATION DIVISION OF UNDERGROUND STORAGE TANKS 4 TH Floor, L & C Tower 401 Church Street Nashville, TN 37243-1541 UST OPERATIONS INSPECTION Mo /Day
More informationPipe Support The Fast, Economical Solution for Low Pressure Pipeline Repair
CLOCK SPRING Pipe Support The Fast, Economical Solution for Low Pressure Pipeline Repair 3 x 18 repairs were made in support locations. The Pipe could not be raised so blocks were inserted and the supports
More informationThis article discusses a tank
CASE HISTORY Hot Oil Aboveground Storage Tank Bottom Corrosion Failure and Cathodic Protection Upgrade Part 2 KEVIN C. GARRITY AND PHILIP D. SIMON, CC Technologies, Inc. Several types of anode installations
More informationMonthly Checklist For Depot
Monthly Checklist For Depot ANNEXURE 1.L(iv) TANK FARM Notes : i. The scope covers piping, valve & fittings, general housekeeping, pumps & motors, effluent management, fire protection and security within
More informationMonitoring Cathodic Protection of Natural Gas Pipelines
Monitoring Cathodic Protection of Natural Gas Pipelines Period #8 Basic Corrosion Course 2017 February 21-23, 2017 Steve Glover - Vectren 0 Chapter Objective: Introduction Reasons to monitor What to monitor
More informationFINAL REPORT CATHODIC PROTECTION EVALUATION. 42-Inch Water Transmission Pipeline Contract 1 Station 0+00 to South Texas Water Authority
FINAL REPORT CATHODIC PROTECTION EVALUATION 42-Inch Water Transmission Pipeline Contract 1 Station 0+00 to 50+00 South Texas Water Authority Prepared for: South Texas Water Authority P.O. Box 1701 Kingsville,
More informationHDPE FUSIBLE VALVES EXPECT INNOVATION
AVK HDPE FUSIBLE VALVES HDPE FUSIBLE VALVES EXPECT INNOVATION AVK HDPE VALVES SERIES 89 FUSIBLE BUTTERFLY VALVE Series 89 fusible butterfly valves are designed for quick, direct heat butt-fusion or electrofusion
More informationNo Infrared Refrigerant Leak Detector
No. 22791 Infrared Refrigerant Leak Detector Operator s Manual Product Description The Robinair No. 22791 uses infrared optics to create a refrigerant leak detector that combines sensitivity, speed, battery
More informationBroetje-Automation Company Standard Structural component specification for welded parts
Broetje-Automation Company Standard Table of Contents Application Area and Purpose 3 1 Structural components pursuant to DIN 1090 4 1.1 Structural component classification 4 1.1.1 Steel components < Strength
More informationThe Gradient Control Mat (GCM)
The (GCM) Installation Instructions INTRODUCTION Most gradient control mats are designed and installed around above ground pipeline appurtenances to limit power frequency voltages. The Dairyland gradient
More informationGUIDELINE FOR GLOVEBOXES THIRD EDITION AGS-G001 February 2007
GUIDELINE FOR GLOVEBOXES THIRD EDITION AGS-G001 February 2007 AMERICAN GLOVEBOX SOCIETY STANDARDS DEVELOPMENT COMMITTEE All Rights Reserved Copyright 2007 No portion may be duplicated without written consent
More informationMethodologies and practices for non-piggable lines Andreas Landsteiner Integrity Department - Transalpine Pipeline (TAL)
Methodologies and practices for non-piggable lines Andreas Landsteiner Integrity Department - Transalpine Pipeline (TAL) COPEX 2010 Brussels 1 Presentation overview (1) What are non-piggable lines? (2)
More informationINSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER SAMPLE / INJECTION PUMP
INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER SAMPLE / INJECTION PUMP MODEL SSO-9MED DRAWING NUMBERS AD243DI AD243DK AD243DK.K1 MANUAL NUMBER IOM-175 REVISION Rev. B, 3/21/2017 TABLE OF CONTENTS
More informationINSTALLATION INSTRUCTIONS
R913 FRP COMPOSITE STEEL UNDERGROUND STORAGE TANKS INSTALLATION INSTRUCTIONS February 2017 1.0 EXCAVATION AND BEDDING 1.1 The bottom of the excavation shall be covered with a minimum of 12 inches (305
More informationAn Introduction to Constructing and Maintaining Cathodic Protection Systems
An Introduction to Constructing and Maintaining Cathodic Protection Systems Course No: T02-009 Credit: 2 PDH J. Paul Guyer, P.E., R.A., Fellow ASCE, Fellow AEI Continuing Education and Development, Inc.
More informationRolls -Royce M250--C47M OPERATION AND MAINTENANCE
TABLE 603 Inspection Checksheet Owner Date A/C Make/Model S/N Reg No. TSN Engine S/N TSN TSO This inspection checksheet is to be used when performing scheduled inspections. This form may be locally reproduced
More informationSPCC Regulation Integrity and Leak Testing Methods
SPCC Regulation Integrity and Leak Testing Methods NISTM New England December 3 rd, 2015 Founded in 1988, Tanknology has grown to become one of the largest testing and inspection service companies in the
More informationPIPELINE INSPECTION SURVEY QUESTIONNAIRE
ARKA PETROGAS PIPELINE PIPELINE INSPECTION SURVEY QUESTIONNAIRE Project: PipeLine Name: ARKALINE Proj. No.:.. Please complete questionnaire as accurate as possible. Phone: +98 21-65611626 Fax: +98 21-65611627
More informationOfficial Journal of the European Union L 298/39
16.11.2011 Official Journal of the European Union L 298/39 B3 6.8 Bearings 1 2 2 1 Purpose of bearings, loads, material, construction; Types of bearings and their application. 6.9 Transmissions 1 2 2 1
More informationProcessing Plant Enters. the Pipeline World. A Case Study of a Chemically Welded Anomaly Repair. By Randy Vaughn. R&F Pipecon Resources
Processing Plant Enters the Pipeline World A Case Study of a Chemically Welded Anomaly Repair By Randy Vaughn R&F Pipecon Resources Introduction A processing plant entered into the pipeline industry in
More informationINSTALLATION, OPERATION, & MAINTENANCE MANUAL Models # MM-30, MM-30HT, MM-50, MM-50HT, & MM-50 EXL with Special HP Tool and Special HP EXL Tool
INSTALLATION, OPERATION, & MAINTENANCE MANUAL Models # MM-30, MM-30HT, MM-50, MM-50HT, & MM-50 EXL with Special HP Tool and Special HP EXL Tool INSTALLATION INSTRUCTIONS FOR THE MODEL MM-30 & MODEL MM-50
More informationCONTENTS. Foreword...iii. 1. Introduction...1
Installation of Aboveground Storage Systems for Motor-Vehicle Fueling CONTENTS Foreword...iii SECTIONS 1. Introduction...1 1.1 Background...1 1.2 Purpose...1 1.3 Scope...1 1.4 Source...1 1.5 Use of PEI/RP100...1
More informationRELIABLE AND EFFICIENT SYSTEMS
RELIABLE AND EFFICIENT SYSTEMS Systems must be leak-free as possible All systems leak Piping materials are slightly porous Very small leaks are not detectable and do not affect system efficiency Some systems
More informationHighway Crossings - Cased or Uncased
Highway Crossings - Cased or Uncased Maryland Quality Initiative Annual Conference Baltimore Convention Center Baltimore, Maryland Steve Nanney PHMSA Office of Pipeline Safety January 31, 2013-1 - PHMSA
More informationCASE STUDY ON PIPELINE UNDER-PROTECTION ALONG WITH MITIGATION METHODS. Vipul Vilas Sawant. Mahanagar Gas Ltd, Mumbai, India
Paper No. CAP34 CASE STUDY ON PIPELINE UNDER-PROTECTION ALONG WITH MITIGATION METHODS Vipul Vilas Sawant Mahanagar Gas Ltd, Mumbai, India vsawant@mahanagargas. com ABSTRACT Mahanagar Gas Ltd is a City
More informationClient Success Story Sheri Baucom Senior Advisor II
Client Success Story - 2017 Sheri Baucom Senior Advisor II Overview The following is a description of an actual project completed in 2016 where RCP was deployed onsite to validate a pressure test using
More informationThis publication is copyrighted and intended for the sole use of General Industries - 07/07/2016
AQUASWEEP JUNE 2009 INSTALLATION INSTRUCTIONS FOR AQUASWEEP UNDERGROUND OIL WATER SEPARATORS PREFACE i. Install the AquaSweep Oil Water Separator using personnel who have knowledge and experience in procedures
More informationTHE APPLICATION OF LONG RANGE GUIDED ULTRASONICS FOR THE INSPECTION OF RISER PIPES
THE APPLICATION OF LONG RANGE GUIDED ULTRASONICS FOR THE INSPECTION OF RISER PIPES J. McGregor, B. Nooteboom, N. Ivory PTAS-ITS Lot 1 and 2 Tapak Perindustrian Pekan Belait, Jalan Setia Di-Raja, Kuala
More informationANNUAL UST SYSTEM INSPECTION CHECKLIST
APPENDIX A-3: SAMPLE FORM FOR ANNUAL UNDERGROUND STORAGE SYSTEM INSPECTION CHECKLIST Page 1 ANNUAL UST SYSTEM INSPECTION CHECKLIST Facility ID# Facility Name/Address Qualified Technician Signature Date
More informationApplication for Permit to Install Underground Storage Tanks (Petroleum or Hazardous Substances) 1. Owner Information 2. Installation Site Information
Papillion/La Vista Fire Marshal s Office Fuels Division FLST Section 146 rth Adams Street Papillion, NE 68046 (402) 829-1398 Application for Permit to Install Underground Storage Tanks (Petroleum or Hazardous
More informationAnnex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005
Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-11065-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 08.02.2016 to 07.02.2021 Holder of certificate: Actemium
More informationMitigation of External Corrosion on Buried Carbon Steel Pipeline Systems July/2018
Best Management Practice Mitigation of External Corrosion on Buried Carbon Steel Pipeline Systems July/2018 2018-0028 The Canadian Association of Petroleum Producers (CAPP) represents companies, large
More informationVal-Matic Extended Bonnet Assembly Instructions
Manual No. EBAI-OM-2 Val-Matic Extended Bonnet Assembly Instructions Operation, Maintenance and Installation Manual DESCRIPTION OF ASSEMBLY... 1 INSTALLATION INSTRUCTIONS... 1 TROUBLESHOOTING... 1 PARTS
More informationSeptember 2012 / M&H C502 / Model 129
GENERAL FEATURES / GENERAL SPEC M&H AWWA C502 FIRE HYDRANTS Model 129 Traffic Model 250 PSI Working Pressure 500 PSI Hydrostatic Test AWWA UL / FM Approved Type: Compression type, opening against line
More informationGF Piping Systems. SurTap System Operation with VersaTap Fittings Manual
GF Piping Systems SurTap System Operation with VersaTap Fittings Manual Thank you for selecting Georg Fischer Central Plastics products. GFCP strives to deliver the best technology and materials combined
More informationFISC Puget Sound Manchester Fuel Department. Maintenance, Leak Detection in Large Underground Storage Tanks. Glenn E. Schmitt, P.E.
FISC Puget Sound Manchester Fuel Department Glenn E. Schmitt, P.E. Environmental Director Fleet and Industrial Supply Center Puget Sound Maintenance, Leak Detection in Large Underground Storage Tanks Ready.
More informationCathodic Protection for AST s. Why is Cathodic Protection Important?
Cathodic Protection for AST s Presented by: James T. Lary Corrpro Companies, inc. 1055 West Smith Road Medina, Ohio 44256 jlary@corrpro.com 330-241-6615 Why is Cathodic Protection Important? Preserve Assets
More informationAsset Protection Cathodic Protection Testing of Insulating Joints. Work Instruction No.:
Asset Protection Cathodic Protection Testing of Insulating Joints Approved by: Manager Pipeline Standards 1 PURPOSE This work instruction describes the requirements and process for testing the integrity
More informationHOT TAPPING & PLUGGING SOLUTIONS
HOT TAPPING & PLUGGING SOLUTIONS STOPPLE Plus System Combined with a LOCK-O-RING Plus completion plug, the STOPPLE Plus fitting reduces installation time, simplifies the setting process, and eliminates
More informationReport of Inspection
P. O. Box 8238 Searcy, AR 72145 866.811.5237 / 501.279.1166 Fax: 501.279.1225 As required by NFPA 1911 19.3: CFS Inspections is accredited to the requirements of ISO/IEC 17020. Report of Inspection SAFET
More informationPIPELINE. catalogue. Pipeline construc on and maintenance Products & Solu ons
PIPELINE catalogue Pipeline construc on and maintenance Products & Solu ons About us... Founded in 1993, as agent and distributor of world leader brands, in pipeline an -corrosion coa ng; such as Raychem.
More informationLAR Training. Series 8000 Pneumatic Safety Shut Off Valves Mark Lampe May,
LAR Training Series 8000 Pneumatic Safety Shut Off Valves Mark Lampe May, 18 2015 Series 8000 Pneumatic Valve Unique vertical space saving design Maintenance free gas and fluid seal that eliminates packing
More informationBaumann Sanitary Diaphragm Angle and Inline Control Valve
Instruction Manual 84000 Valve Baumann 84000 Sanitary Diaphragm Angle and Inline Control Valve Contents Introduction... 1 Scope of Manual... 1 Safety Precautions... 2 Maintenance... 2 Flow Direction...
More informationAlgeria, November 2016
Advanced Non-Destructive Testing for Tanks and Pipelines Algeria, November 2016 Params. K Details of Selected Advanced NDT Techniques On-Line Inspection What is On-Line Inspection? Check the Mechanical
More informationMass Tank Inspection Services, LLC 29 Abbey Lane Middleboro, MA masstankinspection.com
June 18, 2018 Mrs. Nancy Cole Administrator Village of Eidelweiss 1680 Conway RD Madison, NH 03849 Mass Tank Inspection Services, LLC 29 Abbey Lane Middleboro, MA 02346 508-947-8826 masstankinspection.com
More informationReport No.: Name of Ship: Plans referred during Initial Survey:
Report on the Surveys Concerning International Oil Pollution Prevention Certificate Part 7 Survey of installation for discharges from cargo spaces Initial/ Annual/ Intermediate/ Renewal/ Change of Flag
More informationDONKIN ASSET PROTECTION SYSTEM WARRANTY UP TO 20 YEARS* DONKIN ASSET PROTECTION SYSTEM
DONKIN ASSET PROTECTION SYSTEM WARRANTY UP TO 20 YEARS* DONKIN ASSET PROTECTION SYSTEM THE DONKIN ASSET PROTECTION SYSTEM FOR VALVES As part of AVK s commitment to provide our customers with solutions,
More informationAnnex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005
Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-17579-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 07.07.2017 to 06.07.2022 Holder of certificate: gammatest
More informationReport of the Pipeline Safety Department. Home Explosion January 2, Whispering Hollow Drive Oklahoma City, Oklahoma
BOB ANTHONY TODD HIETT DANA MURPHY Commissioner Commissioner Commissioner OKLAHOMA CORPORATION COMMISSION P.O. BOX 52000 OKLAHOMA CITY, OKLAHOMA 73152-2000 Transportation Division Pipeline Safety Department
More information7. UST Piping Corrosion Protection. NCDENR Division of Waste Management Underground Storage Tank Section
7. UST Piping Corrosion Protection NCDENR Division of Waste Management Underground Storage Tank Section 1 Where piping connects to tank Piping Corrosion Protection 2 Main run of piping 3 Where piping connects
More informationLINE STOPPING. Extending and modifying your existing pressurized system while it s under full operating conditions.
Extending and modifying your existing pressurized system while it s under full operating conditions. Line Stops are used to temporarily shut down a pipeline system to complete modifications or repairs.
More informationFirst Quality Solutions
First Quality Solutions Turbine Inspection Reports www.firstqualitysolutions.org VISUAL EXAMINATION REPORT Customer: Sample Turbine Outage PO: 104568912 Report No: S1 Component: Turbine Components WO:
More informationEXPECT RELIABILITY AVK RESILIENT SEATED GATE VALVES
EXPECT RELIABILITY AVK RESILIENT SEATED GATE VALVES AVK VALVES STANDARD FEATURES AVK STANDARD FEATURES AVK Gate Valves are made of ductile iron and meet or exceed AWWA C509 or C515 ASTM A582 stainless
More informationPIPELINE REPAIR OF CORROSION AND DENTS: A COMPARISON OF COMPOSITE REPAIRS AND STEEL SLEEVES
Proceedings of the 2014 10th International Pipeline Conference IPC2014 September 29 - October 3, 2014, Calgary, Alberta, Canada IPC2014-33410 PIPELINE REPAIR OF CORROSION AND DENTS: A COMPARISON OF COMPOSITE
More informationAtmos Energy DOT Report-Distribution Leaks Cause of Leak WTX LA MS CO KS KY M-TX TN VA Total
Atmos Energy 2017 2017 DOT Report-Distribution Leaks Cause of Leak WTX LA MS CO KS KY M-TX TN VA Total CORROSION Hazardous Main 61 10 24 13 15 5 148 2 1 279 Non-Hazardous Main 160 156 93 46 155 64 728
More informationPIPELINE INTEGRITY CONFERENCE BHR GROUP 5th-7th NOVEMBER 2008 SCHIPOL, THE NETHERLANDS PIPPELINE IN INDIA
PIPELINE INTEGRITY CONFERENCE BHR GROUP 5th-7th NOVEMBER 2008 SCHIPOL, THE NETHERLANDS REHABILITATING A MAJOR OIL PIPPELINE IN INDIA K.G. GUPTA, INDIAN OIL CORPORATION LTD, INDIA R. JOHN, BERRY PLASTICS
More informationDaikin Steam Coils. Installation and Maintenance Manual IM 901. Types HI-F5, HI-F8, & E-F5. Group: Applied Air. Part Number: IM 901
Installation and Maintenance Manual IM 901 Daikin Steam Coils Group: Applied Air Part Number: IM 901 Date: February 2008 Types HI-F5, HI-F8, & E-F5 2008 Daikin Applied Contents Introduction... 3 General
More informationTRADE EXPERIENCE LOG BOOK CANADIAN PETROLEUM CONTRACTORS ASSOCIATION. Petroleum Mechanic Training & Certification
CANADIAN PETROLEUM CONTRACTORS ASSOCIATION Petroleum Mechanic Training & Certification TRADE EXPERIENCE LOG BOOK PM1 - Service & Maintenance PM2 - Underground Installation PM3 - Aboveground Installation
More informationKENNEDY VALVE Plant and Industrial Group 1021 East Water Street Elmira, New York Telephone (607) Fax (607)
KENNEDY VALVE Plant and Industrial Group 1021 East Water Street Elmira, New York 14901 Telephone (607) 734-2211 Fax (607) 734-3288 INSTALLATION, OPERATION, AND MAINTENANCE MANUAL General ECCENTRIC PLUG
More information3-20 2FII & Groundhog Bonded Seat Butterfly Valve. Operation and Maintenance Manual. Job Name: Contractor: Date:
3-20 2FII & Groundhog Bonded Seat Butterfly Valve Operation and Maintenance Manual Job Name: Contractor: Date: Document #:3202FIIGD Revision Date: 1/10/11 SAFETY MESSAGES All safety messages in the instructions
More information7. Protection System Testing
MANUAL FOR INSTALLATION AND MONITORING OF UNDERGROUND STORAGE TANKS WITH FACTORY INSTALLED ANODES 1. SCOPE Manufactured by: Granby Industries 1020 André-Liné Granby, Québec, Canada, J2J 1J9. Telephone:
More informationSECTION FACILITY FUEL - NATURAL GAS PIPING AND SYSTEMS
SECTION 23 11 23 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Fuel Pipe and Pipe Fittings - General 2. Steel Pipe and Fittings, Above Grade 3. Steel Pipe and Fittings, Below Grade 4. Polyethylene
More informationVRX Plunger. Advanced Control Valve
VRX Plunger Advanced Control Valve Av-Tek is leading the way in the development, manufacturing, and implementation of high-quality valves for use municipal, industrial, and sea water industries. Our premium
More informationPROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS CITY, CALIFORNIA
The following standard specification is intended to be edited according to the specifics of the project. Brackets [ ] and areas shaded in gray [e.g. format] indicate requirements that are optional depending
More informationAUTOMOTIVE TECHNOLOGY 41 COURSE SYLLABUS
AUTOMOTIVE TECHNOLOGY 41 COURSE SYLLABUS Course Description: Recommended: AT1 or pass the Auto Tech 1 Placement Test. Principles of engine rebuilding, includes diagnosis, removing, disassembly, cleaning,
More informationInline Ultrasonic Flowmeter
M-1500 Series Installation and Operating Manual The M-1500 series is an inline primary flow sensor and externally mounted controller unit. The flow sensor is a straight through flow tube that uses Transit
More informationSECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY
SECTION 230533 - PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pressure gages. 2. Pressure gage taps. 3. Thermometers. 4. Thermometer supports. 5. Test plugs. 6. Static pressure
More informationCable-Tight Wire Management System
Cable-Tight Wire Management System Installation Guide Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Tel: +1 608 838 8786 800 225 9787 Fax: +1 608 838 6433 www.franklinfueling.com Safety
More informationPrevention vs. Reaction The Importance of Asset Integrity
Prevention vs. Reaction The Importance of Asset Integrity How Your Assets Typically Age Inspections Potential Failure Condition Functional Failure Time P-F Interval Why is Asset Integrity so Important?
More informationGAS DISTRIBUTION PRODUCTS METER RISERS
GAS DISTRIBUTION PRODUCTS METER RISERS INDUSTRIES ABOUT US THE ULTIMATE CONNECTION Our Company Continental Industries, headquartered in Tulsa, Oklahoma, was formed in 1958 and is today a leading manufacturer
More informationCHAPTER 115 LEAK DETECTION AND REPAIR (LDAR) PROGRAM CHANGES
CHAPTER 115 LEAK DETECTION AND REPAIR (LDAR) PROGRAM CHANGES FOR ALL FOUR OZONE NONATTAINMENT AREAS:! Delay of repair beyond the next process unit shutdown is allowed if the component is isolated from
More information