Appendix B Kinder Morgan Operator Qualification Program List of Covered Tasks Hazardous Liquid Pipelines Part 195 revised 8/24/2018
|
|
- Everett Randall Skinner
- 5 years ago
- Views:
Transcription
1 Abnormal Operating Conditions Outside of Room Abnormal Operating Conditions Inside of Room Measure Structure-to-Soil Potentials Advanced Cathodic Testing Active Corrosion/MIC Testing Maintain Cathodic Test Leads (ETSs) Read Rectifier Use of Current Interrupters on Rectifiers Adjust Rectifier Maintain Rectifier Atmospheric Corrosion Inspection of Coatings Atmospheric Corrosion Surface Preparation Atmospheric Corrosion Application of Coatings Appendix B Kinder Morgan Operator Program N/A a, 402f, 403 N/A 1:1 1:5 Page 1 of , 1102, : a1 1: , 268, a, 402f, 403 3, 573a 452h2, 571, 575, a2, 452(h) 1: a, 567b, 571 1: c 1: a2 1: c, 573e 1: c, 573e 1:1 203, b, 583c 1:5 203, , 903, a, 581b, 581c2, 559,
2 Kinder Morgan Operator Program Electronic Holiday Detection External Coatings on Buried or Submerged Components Application and Repair Cathodic Protection Remediation Internal Corrosion Injection Rate Internal Corrosion Monitor Injection Rate Internal Corrosion Insertion and Removal of Probes and Coupons Internal Corrosion Monitoring Probes Internal Corrosion Inspect Internal Pipe Surfaces Inspect Aerial Indicator on Rectifier Inspect and Perform Electrical Test of Bonds Reserved for Future Use Monitoring of Vapor Corrosion Inhibitor System Tanks 1: :5 203, 903, 918 1:1 903, 906 1: : : , , 565, 567, 575, 576e, 577, 585 1:1 903, b, 579c, 579d 1: c 1: c 1: a, 577b 1: d Page 2 of 8
3 Kinder Morgan Operator Program Visual Inspection of Buried Pipe and Components When Exposed Visual Inspection of Internal Surface of Pipe Inspect Navigable Waterway Crossing Inspect Atmospheric Breakout Tanks Monthly External In-Service Inspect Atmospheric Breakout Tanks API 653 External In-Service Inspect Atmospheric Breakout Tanks API 653 Out of Service Overfill Protective Devices Manual Testing Inspect Pressurized Breakout Tanks External Inspection Repair Pressurized Breakout Tanks Reserved for Future Use Non-Destructive Testing of Welds Reserved for Future Use Damage Prevention during Excavation Activities 1:1 1:1 109, 203, 204, 213, 268, 454, 903, , 213, c, 557, 559, 561, 583b, 583c 579, 585 1: b 1:2 918, , 432a, 432b 1: , 432a, 432b 1: , 432a, 432b 1: : , 432a, 432b 1: a, 205b1, 205b2, 205b3, 307, 432c 1: a, 228b, 234 1:1 204, Page 3 of 8
4 Kinder Morgan Operator Program Inspection Activities Welding on Pipeline System Inspection Activities Non-Destructive Testing Conduct DOT Pipeline Pressure Tests CPM Leak Detection Inspect Buried Pipe when Exposed Measure Damage on Pipe Manual Measurement Measure Wall Thickness of Pipe Ultrasonic Measurement Place and Maintain Permanent Line Markers Inspect Surface Conditions of Right-of-Way Inspection Following Blasting DOT Inspection of Valves Moving In-Service Pipe 1: : a, 234 1:2 917, : , , 304, 305, 306, 307, 308, 310 1:1 204, a, 442c6, 561, 569 1:1 213, 403, 406, , 587 1: , 587 1: :1 204, 215, 221 1: a, 442 1: , 258, 420b 1: , 403a, 424 Page 4 of 8
5 Kinder Morgan Operator Program Inspection of Clearance of Existing Pipe to Underground Structures Inspection of Support Structures on Existing Aboveground Components Backfilling an Excavation Composite Sleeve Application - ClockSpring 1 yr General Pipeline Repair Full Encirclement Sleeve General Pipeline Repair Component Replacement General Pipeline Repair Stoppling General Pipeline Repair Hot Tap Evacuation of Liquids from Pipe Using Inert Gas Evacuation of Liquids from Pipe Using Liquid Flammable Gas Evacuation of Liquids from Pipe Safe Disconnecting of Abandoned Pipeline Facilities 1: , 403a, 442 1: , 254, 403a 1: , 252, 403a 1:0 1:2 109, 201, 203, 213, , 280, 401, 402, 404, 405, a, 422, 585a2 403a, 422, 585a2 1:2 213, , 422, 416f 1: a, 422 1:2 109, a, 422 1:3 1:3 1:3 1:3 226, 227, 234, 235, , 227, , 227, , 225, c10, 402c11, 403a, c10, 402c11, 403a, 405, c10, 402c11, 403a, 405, c10, 11 Page 5 of 8
6 Kinder Morgan Operator Program Welding on Existing Pipeline Systems 1 yr Locate Pipeline Temporary Marking of Pipeline Installation/Use of Vapor Barriers Provide Security for Pipeline Facilities Monitor by Remote Security Devices Breakout Tanks Static Protection Line Velocity Reserved for Future Use Reserved for Future Use Overfill Protective Devices Knowledge of Tank Level Alarms Overfill Protective Devices Response to Tank Level Alarms Operations of Pipeline System Start Pipeline 1:0 1:1 401, 402, 403, 404, 405, 406, 407, 407A, 454, 455, 456 1:1 204, a, 442 1:1 204, c2 222, 226, 240 1: , 214, 216, 222, 224, 226, 228, 230, 234, 308, 403a, 422, 424, 432, , 402c10 258a, 264c, 420c, 434, 436, 438 1: a, 408, 420c, 436 1: a, 405b 1: : :1 501, c11, 403a3, 428a, 428b, 428c, 428d 402c11, 402e1, 403a4, 428a, 428b, 428c Page 6 of 8
7 Kinder Morgan Operator Program Operations of Pipeline System Normal Shutdown From Normally ling Location Operations of Pipeline System Normal Shutdown From Location Not Normally ling Operations of Pipeline System Emergency Pipeline Shutdown Operations of Pipeline System Emergency Station Shut-In Operations of Pipeline System Unit Adjustment Operations of Pipeline System Tank Management Operations of Pipeline System Monitor Communications Operations of Pipeline System Monitor Leak Detection and Line Integrity Operations of Pipeline System Monitor Flow Rates Operations of Pipeline System Maintain Pressures within Allowable Limits Operations of Pipeline System Manually or Remotely Open or Close Valves Operations of Pipeline System Operating Pressure Test 1:1 1:1 1:1 223, 501, 502, , 501, 502, , 500, 1101, :1 223, 500 1:1 501, 502 1:1 1101, c7, 8,9, 402c8, 402c9, 1:1 704, c9, 402d, 402e, 408a 1: , 55, 58, 402e1, 402e2, 402e3, 402e9, 408, 446 1:1 1102, c9, 402d, 402e, 408 1: : :1 208, 1600 Page 7 of 8
8 Kinder Morgan Operator Program Launching and Receiving Internal Devices Maintain and Repair Power Valve Actuators Preventive Maintenance Valve Actuators Lubricate Valves Repair Valves Overpressure Safety Devices Inspect, Test and Calibrate Relief Valves Overpressure Safety Devices Pressure Switches and Transmitters Pressure Limiting Devices Inspect, Test and Calibrate Mechanical Valves Pressure Limiting Devices Inspect, Test and Calibrate Electronic/Electro-Hydraulic Loops Overfill Protective Devices Repair and Replacement 1: : a, 420b, 420c 1: a, 420b, 420c 1: a, 420b, 420c 1: , 206, 420, 422b, 428 1: , 206, 262c, 420, 422b, 428 1:1 703, c, 428a 1: a 1: a 1: c Page 8 of 8
Appendix B Kinder Morgan Operator Qualification Program List of Covered Tasks Hazardous Liquid Pipelines Part 195 revised 12/12/2017
Abnormal Operating Conditions Outside of 101.01 Room Abnormal Operating Conditions Inside of 101.02 Room 102.01 Measure Structure-to-Soil Potentials 102.02 Advanced Cathodic Testing 102.03 Active Corrosion/MIC
More informationEpic Consolidated Operations LLC Contractor Covered Task List Last updated 9/6/2018
003 Test Breakout Tank Overfill Protective 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective 195.428 Oral 005 Repair Breakout Tank Overfill Protective 195.428 006 Inspection of Breakout
More informationTransCanada US Contractor Covered Task List Last updated 9/27/2018
003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 Oral 005 Repair Breakout Tank Overfill Protective Devices 195.428
More informationEnbridge Gas Transmission and Midstream and Enbridge Liquid Pipelines (Express-Platte) Contractor Covered Task List Last updated 8/30/2018
001 Provide Security for Pipeline Facilities 195.436 Oral 003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 Oral
More informationBoardwalk Pipeline Partners, LP Contractor Covered Task List Last updated 9/17/2018
003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 Oral 005 Repair Breakout Tank Overfill Protective Devices 195.428
More informationColumbia Pipeline Group Contractor Covered Task List Last updated 1/8/2018
001 Provide Security for Pipeline Facilities 195.436 Oral 003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 Oral
More informationSaddle Butte Rockies Midstream LLC Contractor Covered Task List Last updated 12/6/2017
003 Test Breakout Tank Overfill Protective N/A 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective N/A 195.428 Oral 005 Repair Breakout Tank Overfill Protective N/A 195.428 007 Operate
More informationSouthern Star Central Gas Pipeline Contractor Covered Task List Last updated 8/15/2018
007 Operate Valves 008 Measurement of Wall Thickness with Ultrasonic Device 018 Inspect Navigable Waterway Crossing 195.412(b) 201 Abnormal Operating Conditions Related to Welding on Pipelines 192.225
More informationNorthern Natural Gas Contractor Covered Task List Last updated 4/26/2018
001 Provide Security for Pipeline Facilities 195.436 Oral 003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 Oral
More informationWilliams Contractor Covered Task List Last updated 11/7/2017
003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 Oral 005 Repair Breakout Tank Overfill Protective Devices 195.428
More informationEnergy Transfer Partners LP Contractor Covered Task List Last updated 3/2/2018
001 Provide Security for Pipeline Facilities 195.436 Oral 003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 Oral
More informationEnLink Midstream Contractor Covered Task List Last updated 11/8/2017
003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 005 Repair Breakout Tank Overfill Protective Devices 195.428
More informationHoward Midstream Energy Partners LLC Contractor Covered Task List Last updated 10/11/2013
001 Provide Security for Pipeline Facilities 195.436 Oral 003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 005
More informationEnergy Transfer Partners LP Contractor Covered Task List Last updated 12/10/2018
001 Provide Security for Pipeline Facilities 195.436 Oral 003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 005
More informationDCP Midstream Contractor Covered Task List Last updated 7/11/2018
001 Provide Security for Pipeline Facilities 195.436 Oral 007 Operate Valves 008 Measurement of Wall Thickness with Ultrasonic Device 009 Movement and/or Relocation of Liquid Pipelines 195.424 011 Inspect,
More informationNoble Energy Contractor Covered Task List Last updated 2/20/2019
003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 005 Repair Breakout Tank Overfill Protective Devices 195.428
More informationDominion Energy Questar Pipeline LLC Contractor Covered Task List Last updated 10/3/2017
007 Operate Valves 008 Measurement of Wall Thickness with Ultrasonic Device 103 Non-destructive Testing (Other than testing of welds) -- Mag Particle 104 Non-destructive Testing (Other than testing of
More informationOperator Qualification (OQ) Report
AOCF 66102/67107 Abnormal Operating Conditions Field for Natural Gas and Hazardous Liquids 5/15/2014 5/15/2017 AOCG 67107 Abnormal Operating Conditions for Natural Gas 5/16/2014 5/16/2017 TM001 66101 02
More informationAppendix A Kinder Morgan Operator Qualification Program List of Covered Tasks - Natural Gas - Part 192 Revised 12/13/2017
01.01.01 Abnormal Operating Conditions (AOC) - Outside of Room 01.01.02 Abnormal Operating Conditions (AOC) - Inside of Room (new task effective 1/1/2018) 02.01.01 Gas Detection & Alarm System Maintenance
More informationCOVERED TASK Conduct Cathodic Protection Surveys 1 DESCRIPTION ELEMENTS OF TASK 4 PART QUESTION NOTES ABNORMAL OPERATING CONDITIONS
COVERED Conduct Cathodic Protection Surveys 1 Annual surveys are conducted for each operator s pipeline system that is under cathodic protection to ensure that the protection is adequate. This task is
More informationBlack Hills Energy Contractor Covered Task List Last updated 10/10/2018
007 Operate Valves 103 Non-destructive Testing (Other than testing of welds) -- Mag Particle 201 Abnormal Operating Conditions Related to Welding on Pipelines 195.452(h) 192.225 192.227 192.715 192.717
More informationASMECourseCatalog.
ASMECourseCatalog www.energyu.org www.midwestenergy.org ASME Abnormal Operating Conditions... 6 ASME GAS01 Hazards of Natural Gas and Prevention of Accidental Ignition... 6 ASME 0001 Measure Structure-to-Electrolyte
More informationCONTENTS. Foreword...iii. 1. Introduction...1
Installation of Aboveground Storage Systems for Motor-Vehicle Fueling CONTENTS Foreword...iii SECTIONS 1. Introduction...1 1.1 Background...1 1.2 Purpose...1 1.3 Scope...1 1.4 Source...1 1.5 Use of PEI/RP100...1
More informationPIPELINE CORROSION CONTROL
NCCER 13614 Progress Blvd, Alachua, Florida 32615 Phone: (888) 622-3720 E-mail: info@nccer.org PIPELINE CORROSION CONTROL Competencies / Objectives Level One MODULE 66101-02 INTRODUCTION TO THE PIPELINE
More informationFlorida City Gas Contractor Covered Task List
001A Abandonment and deactivation of facilities 192.727 001B 001C 001SUBA Abandonment and deactivation of facilities (service lines not in use) Abandonment and deactivation of facilities (service lines
More informationPEI/RP Recommended Practices for Installation of Bulk Storage Plants
PEI/RP800-08 Recommended Practices for Installation of Bulk Storage Plants Recommended Practices for Installation of Bulk Storage Plants CONTENTS Foreword...iii. SECTIONS 1. Introduction Page 1.1 Background...1
More informationPENNSYLVANIA ABOVE GROUND STORAGE TANKS
PENNSYLVANIA ABOVE GROUND STORAGE TANKS GZA GeoEnvironmental Inc. by Jeffrey Knepper, LRS, CPG July 27, 2017 PA CODE Chapter 245. Administration of the Storage Tank & Spill Prevention Program AST Definition
More informationES Fueling Aircraft, Vehicles, and Auxiliary Equipment Document Identification Number
ES-301-1.01 Fueling Aircraft, Vehicles, and Auxiliary Equipment Document Identification Number ES-301-1.01 Document Owner: John Hambright 1) Activity Description: Fueling Aircraft, Vehicles, and Auxiliary
More information7. UST Piping Corrosion Protection. NCDENR Division of Waste Management Underground Storage Tank Section
7. UST Piping Corrosion Protection NCDENR Division of Waste Management Underground Storage Tank Section 1 Where piping connects to tank Piping Corrosion Protection 2 Main run of piping 3 Where piping connects
More informationANNUAL UST SYSTEM INSPECTION CHECKLIST
APPENDIX A-3: SAMPLE FORM FOR ANNUAL UNDERGROUND STORAGE SYSTEM INSPECTION CHECKLIST Page 1 ANNUAL UST SYSTEM INSPECTION CHECKLIST Facility ID# Facility Name/Address Qualified Technician Signature Date
More informationNorth Carolina Department of Environment and Natural Resources Division of Waste Management Underground Storage Tank Section
North Carolina Department of Environment and Natural Resources Division of Waste Management Underground Storage Tank Section To discover a release before a major contamination incident occurs Required
More informationInspector's Initials: Tank Owner or Agent Signature: Title: Date:
STATE OF TENNESSEE DEPARTMENT OF ENVIRONMENT AND CONSERVATION DIVISION OF UNDERGROUND STORAGE TANKS 4 TH Floor, L & C Tower 401 Church Street Nashville, TN 37243-1541 UST OPERATIONS INSPECTION Mo /Day
More informationNew UST Installation Inspection Checklist
Nebraska State Fire Marshal Fuels Division - FLST Section 246 South 14 TH Street - Lincoln, NE 68508-1804 (402) 471-9466 New UST Installation Inspection Checklist (Petroleum or Hazardous Substances) Inspection
More informationChanges to EPA s AST & UST Rules. Mott-Smith Consulting Group, LLC
Changes to EPA s AST & UST Rules Mott-Smith Consulting Group, LLC Marshall T. Mott-Smith, President Mott-Smith Consulting Group, LLC 111 North Calhoun Street, Tallahassee, FL 32301 marshall@mott-smithconsulting.com
More informationApplication for Permit to Install Underground Storage Tanks (Petroleum or Hazardous Substances) 1. Owner Information 2. Installation Site Information
Papillion/La Vista Fire Marshal s Office Fuels Division FLST Section 146 rth Adams Street Papillion, NE 68046 (402) 829-1398 Application for Permit to Install Underground Storage Tanks (Petroleum or Hazardous
More informationRegulatory Changes: Chapter 245. AST s
Regulatory Changes: Chapter 245 AST s 245.1 Definitions NEW Aboveground storage tank One or a combination of stationary tanks with a capacity in excess of 250 gallons, including the underground pipes and
More informationCode Requirements for ASTs at Motor Vehicle-Dispensing Stations
Code Requirements for ASTs at Motor Vehicle-Dispensing Stations This table compares aboveground storage tank requirements in the 2015 edition of, to the 2015 International Fire Code (). Please note that
More informationAcoustic Emission Inspection and Monitoring of Petroleum Storage Tanks and Piping
Acoustic Emission Inspection and Monitoring of Petroleum Storage Tanks and Piping Increased Safety with Excellent Money Saving Petroleum tanks used to store crude oil, aviation fuel, gasoline, diesel and
More informationMonitoring Cathodic Protection of Natural Gas Pipelines
Monitoring Cathodic Protection of Natural Gas Pipelines Period #8 Basic Corrosion Course 2017 February 21-23, 2017 Steve Glover - Vectren 0 Chapter Objective: Introduction Reasons to monitor What to monitor
More informationUnderground Storage Tank Annual Compliance Inspection (Revised 1/2015)
Colorado Department of Labor and Employment Division of Oil and Public Safety Compliance Section 633 17 th Street, Suite 500 Denver, CO 80202-3610 Phone: 303-318-8525 Fax: 303-318-8518 Email: cdle_oil_inspection@state.co.us
More information6. Tanks - Leak Detection. NCDENR Division of Waste Management Underground Storage Tank Section
6. Tanks - Leak Detection NCDENR Division of Waste Management Underground Storage Tank Section Why conduct Leak Detection? Required for regulated systems: EXCEPTIONS: Temporarily closed tanks Emergency
More informationFISC Puget Sound Manchester Fuel Department. Maintenance, Leak Detection in Large Underground Storage Tanks. Glenn E. Schmitt, P.E.
FISC Puget Sound Manchester Fuel Department Glenn E. Schmitt, P.E. Environmental Director Fleet and Industrial Supply Center Puget Sound Maintenance, Leak Detection in Large Underground Storage Tanks Ready.
More informationCode Requirements for ASTs at Motor Vehicle-Dispensing Stations
Code Requirements for ASTs at Motor Vehicle-Dispensing Stations This table compares aboveground storage tank requirements in the 2008 edition of NFPA 30A, and the 2006 International Fire Code (IFC). Please
More informationChanges to EPA s AST & UST Rules. Mott-Smith Consulting Group, LLC
Changes to EPA s AST & UST Rules Mott-Smith Consulting Group, LLC Marshall T. Mott-Smith, President Mott-Smith Consulting Group, LLC 111 North Calhoun Street, Tallahassee, FL 32301 marshall@mott-smithconsulting.com
More informationTHE KEY RELATIONSHIPS BETWEEN FIRE CODES, NEW YORK AST REGULATIONS AND SPCC PLANS
THE KEY RELATIONSHIPS BETWEEN FIRE CODES, NEW YORK AST REGULATIONS AND SPCC PLANS Presented by: Joyce A. Rizzo President JD2 Environmental, Inc. 800 East Washington Street West Chester, PA 19380 www.jd2env.com
More informationLACT MEASUREMENT. Total Head = Or PSI = S.G. 2.31
LACT MEASUREMENT Prepared By: Ken A. Steward. P.E. Linco-Electromatic, Inc. 4580 West Wall Street Midland, Texas 79703 The Operation of L.A.C.T. Units The simplest approach to the understanding of the
More informationLINE STOPPING. Extending and modifying your existing pressurized system while it s under full operating conditions.
Extending and modifying your existing pressurized system while it s under full operating conditions. Line Stops are used to temporarily shut down a pipeline system to complete modifications or repairs.
More informationValves and Equipment
DOT/ASME LPG VALVES & TANK EQUIPMENTContainer Valves and Equipment Multi-Service Valve PG. 34 420 Multivalve PG. 35 Underground Multi-Service Valve PG. 36 Underground Multi-Service Valve with Integrated
More information2" - 24" OS Series Butterfly Valves. Operation and Maintenance Manual. Job Name: Contractor: Date:
s Operation and Maintenance Manual Job Name: Contractor: Date: Document #: IOM Revision Date: 10/2/2016 SAFETY MESSAGES All safety messages in the instructions are flagged with an exclamation symbol and
More informationThe Implementation of a Storage Facility Inspection Program. Presented By: John R. Rueckel PCA Engineering, Inc.
The Implementation of a Storage Facility Inspection Program Presented By: John R. Rueckel PCA Engineering, Inc. Storage Facility Inspection Why implement an inspection program? Regulatory Requirements
More informationBackground. AEM Tier 2 Worksheet Petroleum and Oil Product Storage. Glossary. Agricultural Water Quality Principle:
AEM Tier 2 Worksheet Petroleum and Oil Product Storage Glossary Cathodically Protected: Corrosion protection for an underground metal tank or pipe by causing a continuous electric current to flow from
More informationPIGGING PRODUCTS. Capex supply. PIG LAUNCHER and RECEIVER
PIGGING PRODUCTS Capex supply PIG LAUNCHER and RECEIVER Before Cleaning After Cleaning TYPES OF PIGS DISPLACEMENT AND BATCHING PIGS AND PIG WITH BLADES (FOR CLEANING) 2 to 6 3 and 4 PIG with blades 5 to
More informationGeneral information about underground storage tank (UST) fueling systems in every day language.
What this document contains: General information about underground storage tank (UST) fueling systems in every day language. What you need to know about Texas Commission on Environmental Quality (TCEQ)
More informationEnvironment Canada (EC) Storage Tank System Identification Form
Environment Canada (EC) Storage Tank System Identification Form Identification of storage tank systems for the purpose of the Storage Tank Systems for Petroleum Products and Allied Petroleum Products Regulations
More informationNORTH COUNTY FIRE AUTHORITY POLICY & PROCEDURE MANUAL OPERATIONS
PURPOSE: This policy and procedure describes the actions to be taken in the event of an emergency resulting from a fire, explosion, spill, or any unplanned sudden or non sudden release of hazardous waste
More informationAsset Protection Cathodic Protection Testing of Insulating Joints. Work Instruction No.:
Asset Protection Cathodic Protection Testing of Insulating Joints Approved by: Manager Pipeline Standards 1 PURPOSE This work instruction describes the requirements and process for testing the integrity
More informationArizona. UST Contamination How and Why. Presenter David Rabb 2015 ARIZONA STORAGE TANK CONFERENCE PHOENIX, AZ MAY 28, 2015
Arizona UST Contamination How and Why Presenter David Rabb 2015 ARIZONA STORAGE TANK CONFERENCE PHOENIX, AZ MAY 28, 2015 Leak Detection Technologies LDT is made up of a team of technology and application
More informationOKLAHOMA CORPORATION COMMISSION PETROLEUM STORAGE TANK DIVISION THE ABC S OF AST S AN OVERVIEW OF ABOVEGROUND STORAGE TANK REQUIREMENTS
OKLAHOMA CORPORATION COMMISSION PETROLEUM STORAGE TANK DIVISION THE ABC S OF AST S AN OVERVIEW OF ABOVEGROUND STORAGE TANK REQUIREMENTS PO BOX 52000 OKC, OK 73152-2000 www.occeweb.com Created on 10/1/2008
More informationCounty of Fresno DEPARTMENT OF PUBLIC HEALTH
County of Fresno DEPARTMENT OF PUBLIC HEALTH Purpose UNDERGROUND STORAGE TANK CLOSURE GUIDELINES This document has been prepared as a guide for underground storage tank (UST) owners and other interested
More informationCathodic Protection for AST s. Why is Cathodic Protection Important?
Cathodic Protection for AST s Presented by: James T. Lary Corrpro Companies, inc. 1055 West Smith Road Medina, Ohio 44256 jlary@corrpro.com 330-241-6615 Why is Cathodic Protection Important? Preserve Assets
More informationDESIGN, OPERATION & MAINTENANCE OF L.A.C.T. UNITS
DESIGN, OPERATION & MAINTENANCE OF L.A.C.T. UNITS INTRODUCTION The two most common methods of measuring the volume of petroleum liquids are tank gauging and liquid metering. The problems associated with
More informationUnderstanding the Colorado Annual Compliance Package. William Holman & Robert Schlegel Inspectors Division of Oil and Public Safety
Understanding the Colorado Annual Compliance Package William Holman & Robert Schlegel Inspectors Division of Oil and Public Safety Overview Required Documentation: UST / AST Annual Compliance Package Release
More informationRULE 2260 REGISTRATION FOR EQUIPMENT SUBJECT TO CALIFORNIA S GREENHOUSE GAS OIL AND GAS REGULATION
RULE 2260 REGISTRATION FOR EQUIPMENT SUBJECT TO CALIFORNIA S GREENHOUSE GAS OIL AND GAS REGULATION REGISTRATION # [region]-[facility ID#]-OILGAS-[registration #]-[mod #] FACILITY NAME: LOCATION: MAILING
More informationAtmos Energy DOT Report-Distribution Leaks Cause of Leak WTX LA MS CO KS KY M-TX TN VA Total
Atmos Energy 2017 2017 DOT Report-Distribution Leaks Cause of Leak WTX LA MS CO KS KY M-TX TN VA Total CORROSION Hazardous Main 61 10 24 13 15 5 148 2 1 279 Non-Hazardous Main 160 156 93 46 155 64 728
More informationVELAN TRUNNION-MOUNTED
VELAN TRUNNION-MOUNTED Velan s standard trunnion-mounted ball valves offer increased value by incorporating advanced design features. TRUNNION-MOUNTED BALL The ball is fixed and the seat rings are floating,
More informationThis article discusses a tank
CASE HISTORY Hot Oil Aboveground Storage Tank Bottom Corrosion Failure and Cathodic Protection Upgrade Part 2 KEVIN C. GARRITY AND PHILIP D. SIMON, CC Technologies, Inc. Several types of anode installations
More informationNYSDEC PBS REGULATIONS Heating Oil Tanks
1 NYSDEC PBS REGULATIONS Heating Oil Tanks Central Office/Region 2 Division of Environmental Remediation Bulk Storage Compliance Program NISTM 2017 New York Storage Tank Conference Saint Francis College,
More informationNortheast Ohio AWWA October 26, 2017
Northeast Ohio AWWA October 26, 2017 Introduction Karl Dickinson Regional Sales Manager Jack Doheny Companies Sell & Rent Vacuum Trucks, Sewer Cleaning Equipment, & Pipeline Inspection Systems 16 Service
More informationCONTRACTOR S SELF-INSPECTION CHECKLIST for UST INSTALLATION REPLACEMENT UPGRADE RETROFIT REPAIR
Environmental Health - UST Program CONTRACTOR S SELF-INSPECTION CHECKLIST for UST INSTALLATION REPLACEMENT UPGRADE RETROFIT REPAIR As part of our inter-local contract with the Nevada Division of Environmental
More informationState of New Jersey. Department of Environmental Protection Air Quality Permitting
State of New Jersey Department of Environmental Protection Air Quality Permitting General Permit (GP-004B) for Fuel Dispensing Facility Equipped with a Phase I Vapor Recovery Control System This General
More information9.21 Tank Program Guide NYS Office of Mental Health Tank System Installation Guide
- Design Guides A. SITE PLANS: Provide existing condition, removal plan, and proposed installation site plans for all tanks. Plans must include the following: 1. Dimensions of tank and any structural pads.
More informationTank Filling Systems. for Petroleum Products
Tank Filling Systems for Petroleum Products Tank Filling Systems for Petroleum Products page 2 What Is It Used For? Generally used with aboveground storage tanks, although some underground uses as well.
More informationHOT TAPPING & PLUGGING SOLUTIONS
HOT TAPPING & PLUGGING SOLUTIONS STOPPLE Plus System Combined with a LOCK-O-RING Plus completion plug, the STOPPLE Plus fitting reduces installation time, simplifies the setting process, and eliminates
More informationThis publication is copyrighted and intended for the sole use of General Industries - 07/07/2016
AQUASWEEP JUNE 2009 INSTALLATION INSTRUCTIONS FOR AQUASWEEP UNDERGROUND OIL WATER SEPARATORS PREFACE i. Install the AquaSweep Oil Water Separator using personnel who have knowledge and experience in procedures
More informationINSTALLATION INSTRUCTIONS
R913 FRP COMPOSITE STEEL UNDERGROUND STORAGE TANKS INSTALLATION INSTRUCTIONS February 2017 1.0 EXCAVATION AND BEDDING 1.1 The bottom of the excavation shall be covered with a minimum of 12 inches (305
More informationInstallation & Operation Manual
Installation & Operation Manual Thank you for purchasing our AS4795.1 Butterfly Valve. Before installing or operating, please carefully read this manual to know thoroughly how to install or operate. The
More informationOfficial Journal of the European Union L 298/39
16.11.2011 Official Journal of the European Union L 298/39 B3 6.8 Bearings 1 2 2 1 Purpose of bearings, loads, material, construction; Types of bearings and their application. 6.9 Transmissions 1 2 2 1
More informationSPCC Regulation Integrity and Leak Testing Methods
SPCC Regulation Integrity and Leak Testing Methods NISTM New England December 3 rd, 2015 Founded in 1988, Tanknology has grown to become one of the largest testing and inspection service companies in the
More informationFuels Safety Division. Propane Code Adoption Document Amendment
Fuels Safety Division Ref. No.: Rev. No.: FS-201-12 1 Propane Code Adoption Document Amendment Date: December 1, 2012 Date: IN THE MATTER OF: THE TECHNICAL STANDARDS AND SAFETY ACT, 2000, S.O. 2000, c.
More informationLorri Grainawi Steel Tank Institute. PA NISTM April 25, 2013 Harrisburg, PA
Lorri Grainawi Steel Tank Institute PA NISTM April 25, 2013 Harrisburg, PA PEI/RP1200-12 ------------------------------------------------------ 1. Introduction 2. Definitions 3. Safety 4. Tank Secondary
More informationHave you previously been a supplier member? Yes No If yes, most recent year:
International Liquid Terminals Association 1005 N. Glebe Road, Suite 600 Arlington, VA 22201 Phone: 703-875-2011 Fax: 703-875-2018 Email: info@ilta.org Website: www.ilta.org SUPPLIER MEMBER APPLICATION
More informationINSTALLATION, OPERATION, & MAINTENANCE MANUAL Models # MM-30, MM-30HT, MM-50, MM-50HT, & MM-50 EXL with Special HP Tool and Special HP EXL Tool
INSTALLATION, OPERATION, & MAINTENANCE MANUAL Models # MM-30, MM-30HT, MM-50, MM-50HT, & MM-50 EXL with Special HP Tool and Special HP EXL Tool INSTALLATION INSTRUCTIONS FOR THE MODEL MM-30 & MODEL MM-50
More information24-48 HP250II Butterfly Valve. Operation and Maintenance Manual. Job Name: Contractor: Date: Document #: 2448HP250OOOM Revision Date: 1/10/11
24-48 HP250II Butterfly Valve Operation and Maintenance Manual Job Name: Contractor: Date: Document #: 2448HP250OOOM Revision Date: 1/10/11 SAFETY MESSAGES All safety messages in the instructions are flagged
More informationManagement of Underground Storage Tanks
Management of Underground Storage Tanks Course No: C03-049 Credit: 3 PDH Mark Rossow, PhD, PE, Retired Continuing Education and Development, Inc. 9 Greyridge Farm Court Stony Point, NY 10980 P: (877) 322-5800
More informationREVISOR CKIWru. t.tz 42, section 692L et seq.; or. A. system holding: (! a mixture of such hazardous waste and other regulated substances; {!
a-' 06119118 REVISOR CKIWru RD4360 1.1 1.2 1.3 1.4 Pollution Control Agency Proposed Permanent Rules Relating to Underground Storage Tanks 71.50.001.0 APPLICABILITY. [For text of subp I, see M.R.I 1.5
More informationPEI/RP Recommended Practices for the Inspection and Maintenance of UST Systems
PEI/RP900-08 Recommended Practices for the Inspection and Maintenance of UST Systems Recommended Practices for the Inspection and Maintenance of UST Systems CONTENTS Foreword...iii SECTIONS 1. Introduction
More informationNYSDEC CBS Compliance Requirements
NYSDEC CBS Compliance Requirements Peter J. Petriccione, P.E. H2M - Water September 24, 2015 Introduction Definition of a Hazardous Substance and a Chemical Bulk Storage Facility Design Requirements of
More informationHigh-Pressure Pipeline Equipment
BROCHURE High-Pressure Pipeline Equipment High-Pressure Gate Valves PRODUCTS 3 Our standard and customised High-Pressure Gate Valves, compatible with the market pipeline equipment, are designed and manufactured
More informationLEAK DETECTION INTERSTITIAL MONITORING
LEAK DETECTION INTERSTITIAL MONITORING What is Interstitial Monitoring? A monthly Monitoring Method for double walled and integral secondary containment tanks and piping systems. A method that detects
More information(Please type or use black ink)
(Please type or use black ink) PNIPUG ALABAMA DEPARTMENT OF ENVIRONMENTAL MANAGEMENT NOTICE OF PROPOSED UST NEW INSTALLATION OR UPGRADE (Use a separate form for each separate place of operation) Date of
More informationLease Automatic Custody Transfer
Lease Automatic Custody Transfer Angus Manufactured LACT Units Updated 19-Dec-01, Slide 2 LACT Unit Requirements Are used for the automatic unattended measurement of crude oil. Accurately measure the quantity
More informationDual wall sub-base diesel fuel tanks -
Specification sheet Dual wall sub-base diesel fuel tanks - 10-125 kw generator sets Description Cummins offers two series of fuel tanks (basic series and regional series) for the 10~125 kw diesel generator
More informationAPPENDIX D: SPCC REQUIREMENTS OVERVIEW
SPCC Requirements Overview APPENDIX D: SPCC REQUIREMENTS OVERVIEW Preface. The following appendix contains an overview of SPCC requirements, presented both in matrices or timetables, and in a succinct
More informationGauges, Sight Glasses and Vacuum Breakers
Gauges, Sight Glasses and Vacuum Breakers Gauges, Sight Glasses and Vacuum Breakers Gauges Pressure gauges Pressure gauges should be installed in at least the following situations: Upstream of a pressure
More informationFuel Tank Management: PBS, USTs and the Energy Policy Act of 2005
Fuel Tank Management: PBS, USTs and the Energy Policy Act of 2005 Petroleum Bulk Storage 6NYCRR Part 612 614 EPA Underground Storage Tanks 40 CFR Part 280 PBS Program Overview PART 612 PART 613 PART 614
More informationAST REGISTRATION PIPE INSPECTION PE REQUIREMENTS. David D. Bradeson, P.E. Chemung Contracting Corporation
AST REGISTRATION PIPE INSPECTION PE REQUIREMENTS David D. Bradeson, P.E. Chemung Contracting Corporation AST REGISTRATION REQUIRED 9 VAC 25-91-20 Part II individual tank of 660 gal. or greater or aggregate
More informationPipe Support The Fast, Economical Solution for Low Pressure Pipeline Repair
CLOCK SPRING Pipe Support The Fast, Economical Solution for Low Pressure Pipeline Repair 3 x 18 repairs were made in support locations. The Pipe could not be raised so blocks were inserted and the supports
More informationPHMSA Office of Pipeline Safety Dave Mulligan Western Region
PHMSA Office of Pipeline Safety Dave Mulligan Western Region Chevron Pipeline Releases Salt Lake City, Utah June 11, 2010 & December 1, 2011 Dave Mulligan U.S. Department of Transportation (US DOT) Pipeline
More informationTest Stations and Pipe-to-Soil Potential Measurements
Test Stations and Pipe-to-Soil Potential Measurements Period #7 Practical Applications Course 2017 Mark James NACE CP II #5619, NACE CIP I #37041 1 Introduction Test Stations Wire Connection to Pipe Pipe-to-Soil
More informationCHAPTER 115 LEAK DETECTION AND REPAIR (LDAR) PROGRAM CHANGES
CHAPTER 115 LEAK DETECTION AND REPAIR (LDAR) PROGRAM CHANGES FOR ALL FOUR OZONE NONATTAINMENT AREAS:! Delay of repair beyond the next process unit shutdown is allowed if the component is isolated from
More information