Columbia Pipeline Group Contractor Covered Task List Last updated 1/8/2018
|
|
- Chastity Leonard
- 6 years ago
- Views:
Transcription
1 001 Provide Security for Pipeline Facilities Oral 003 Test Breakout Tank Overfill Protective Devices Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices Oral 005 Repair Breakout Tank Overfill Protective Devices Oral 006 Inspection of Breakout Tanks Oral 007 Operate Valves 008 Measurement of Wall Thickness with Ultrasonic Device 020 Pump Stations/Units - Startup, Operation and Shutdown (c)(7) (c)(8) 103 Non-destructive Testing (Other than testing of welds) -- Mag Particle 201 Abnormal Operating Conditions Related to Welding on Pipelines (h) Monitoring of Welding Process (a) (c) Visual Inspection of Welds not Non-Destructively Tested (b) (c) 204 Non-Destructive Testing (Dye Penetrant) Non-Destructive Testing (Mag Particle) Non-Destructive Testing (Ultrasonic) Non-Destructive Testing (X-Ray) Plastic Pipe Joining: Butt Fusion Plastic Pipe Joining: Mechanical Joining Oral Oral Oral Page 1 Copyright Veriforce, LLC. All rights reserved. Rev. 23
2 210 Plastic Pipe Joining: Electrofusion Joining Perform Plastic Fusion Inspection Oral 213 Joining of Metal Pipe and Components by means other than Welding - Threaded and Flanged Connections 214 Joining of Metal Pipe and Components by means other than Welding - Threaded Connections 215 Joining of Metal Pipe and Components by means other than Welding- Flanged Connections 216 Joining of Metal Pipe - Compression Couplings 217 Small Diameter Metal Tubing and Fitting Installation 401 of Buried Pipelines When Exposed Protection of Coating When Backfilling and From Below Ground Supports (d) (c)(6) ( c ) (b) Oral Protection of Coatings From Above Ground Structures (d) 406 Conduct Test to Determine Cathodic Protection Current Requirements (a) Perform Cathodic Protection Survey (a) (e) (e) Oral (a) 408 Inspect Cathodic Protection Rectifier (b) ( c ) 409 Inspect Interference Bonds (c) ( c ) 410 Clear Shorted Casing (c) (b)(1) (a) 411 Inspect/Test to Assure Electrical Isolation is Adequate (d) Oral Install CP Leads on Pipeline Using Exothermic Weld Anode Installation on Submerged Pipeline or Facilities Oral 414 Inspect for Internal Corrosion Whenever Pipe is Removed (b)(1) (c) Page 2 Copyright Veriforce, LLC. All rights reserved. Rev. 23
3 415 Monitoring for Internal Corrosion with Probes and Coupons (d)(5) 416 Monitoring for Internal Corrosion with Gas Samples (b) 417 Atmospheric Corrosion Monitoring General and Localized Corrosion Measurement (Remedial Measures) (a)(b) 419 Cathodic Protection Potential Measurement (a) (d)(8) (b) (a) 420 Soil Resistivity 421 Measurement of Depth of Pitting with Pit Gage Perform Direct Current Voltage Gradient (DCVG) Survey (d)(7) 424 Perform AC Current Attenuation (ACCA) Survey (e) (d)(7) 426 Inspect Pipe Coating with Holiday Detector (a) (a) Inspection of Above or Below Ground Coatings Oral 480 Apply Approved Coating by Hand Application (a) Apply Approved Coatings by Mechanical Spray and Hand Application Methods (a) Apply Approved Coatings by Wrap Application (a) Conduct a Pressure Test (d) 502 Conduct Pressure Test on Pipe that is to be Operated at a Pressure <100 psig 601 Start-up/Shut-down of Pipeline to Assure Operation Within MAOP / MOP (b) (b)(5) 602 Monitoring Pipeline Pressure (b)(5) ( c )(9) Oral Page 3 Copyright Veriforce, LLC. All rights reserved. Rev. 23
4 603 Compressor Units: Startup, Operation, Shutdown and Purging Before Returning to Service 604 Locate, Mark, and Remediate Exposed Pipelines in the Gulf of Mexico (b)(7) (b)(6) (b) Locate Line/Install Temporary Marking of Buried Pipeline (c)(5) (c)(5) 606 Locate and Mark Submerged Pipelines (c)(5) Oral 607 Damage Prevention: Observation of Excavating and Backfilling (c)(6) (b) (c)(6) 608 Damage Prevention for Blasting Near a Pipeline (c)(6) (c)(6) Oral 609 Inspect and Maintain Odorization Equipment (e) 610 Monitor Odorant Concentration (f) 611 Hot Tap (Steel Pipe) Hot Tap (Plastic Pipe) Purge Pipeline Facilities With Gas (a) 614 Purge Pipeline Facilities With Air or Inert Gas (b) (c)(10) Oral 616 Atmospheric Monitoring during Hot Work Operations ( c )(11) 619 Damage Prevention during Vacuum Excavation and Backfilling Activities 661 Launching and/or Receiving Internal Devices (Pigs) (c) (d)(5)(iv ) (d)(9) 701 Patrolling Pipeline and Leakage Survey without Instrument (d)(4) (c)(6) (c)(6) Oral Yes 1: (a) Oral 702 Leakage Survey with Leak Detection Device Placing/Maintaining Line Markers (a) (c) 704 Permanent Field Repair by Grinding Permanent Field Repair Using Composite Materials (Clockspring) Oral Page 4 Copyright Veriforce, LLC. All rights reserved. Rev. 23
5 706 Permanent Field Repair Using Composite Materials (Armor Plate) 707 Permanent Field Repair Using Bolt-On Clamp/Sleeve (a) 708 Permanent Field Repair Using Full Encirclement Weld Sleeve 709 Inspection and Testing of Relief Devices (Compressor Stations, Meter Stations, Regulating Stations) 710 Inspect/Test Compressor Station Remote Shutdown Devices (ESD/EBD) (a) (a) (b) (c) 711 Inspect, Test, and Maintain Systems (c) (b)(1) (b)(1) 712 Programmable Logic lers (c) (b)(1) (a) 713 Test/Maintain Gas Detection and Alarm Systems (c) 714 Inspect and Maintain Pressure ing and Regulating Devices 715 Test and Maintain Pressure Switches and Transmitters in Pressure ing and Regulating Service (a) (b) (a) (b) 716 Inspect, Maintain, and Operate Valves Maintaining Vaults With Pressure Regulating and Pressure ing Equipment 718 Monitoring for Internal Corrosion with Liquid Samples Permanent Field Repair Using Composite Materials (Wrapmaster) 722 Permanent Field Repair Using Composite Materials (Aqua Wrap) 724 Permanent Field Repair Using Composite Materials (PipeWrap A+ / Atlas CFP) (a) (b) ( a ) Aerial Leakage Survey: Transmission Yes 1: Inspection of Material (a)(1) Oral 910 Inspection of Construction Activities (c)(6) CPG 745 Operate Air Mover During Cutting, Grinding and Welding Operations (b) Oral (c)(10) Page 5 Copyright Veriforce, LLC. All rights reserved. Rev. 23
Northern Natural Gas Contractor Covered Task List Last updated 4/26/2018
001 Provide Security for Pipeline Facilities 195.436 Oral 003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 Oral
More informationBoardwalk Pipeline Partners, LP Contractor Covered Task List Last updated 9/17/2018
003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 Oral 005 Repair Breakout Tank Overfill Protective Devices 195.428
More informationWilliams Contractor Covered Task List Last updated 11/7/2017
003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 Oral 005 Repair Breakout Tank Overfill Protective Devices 195.428
More informationEnergy Transfer Partners LP Contractor Covered Task List Last updated 3/2/2018
001 Provide Security for Pipeline Facilities 195.436 Oral 003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 Oral
More informationDCP Midstream Contractor Covered Task List Last updated 7/11/2018
001 Provide Security for Pipeline Facilities 195.436 Oral 007 Operate Valves 008 Measurement of Wall Thickness with Ultrasonic Device 009 Movement and/or Relocation of Liquid Pipelines 195.424 011 Inspect,
More informationTransCanada US Contractor Covered Task List Last updated 9/27/2018
003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 Oral 005 Repair Breakout Tank Overfill Protective Devices 195.428
More informationEnergy Transfer Partners LP Contractor Covered Task List Last updated 12/10/2018
001 Provide Security for Pipeline Facilities 195.436 Oral 003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 005
More informationSouthern Star Central Gas Pipeline Contractor Covered Task List Last updated 8/15/2018
007 Operate Valves 008 Measurement of Wall Thickness with Ultrasonic Device 018 Inspect Navigable Waterway Crossing 195.412(b) 201 Abnormal Operating Conditions Related to Welding on Pipelines 192.225
More informationDominion Energy Questar Pipeline LLC Contractor Covered Task List Last updated 10/3/2017
007 Operate Valves 008 Measurement of Wall Thickness with Ultrasonic Device 103 Non-destructive Testing (Other than testing of welds) -- Mag Particle 104 Non-destructive Testing (Other than testing of
More informationSaddle Butte Rockies Midstream LLC Contractor Covered Task List Last updated 12/6/2017
003 Test Breakout Tank Overfill Protective N/A 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective N/A 195.428 Oral 005 Repair Breakout Tank Overfill Protective N/A 195.428 007 Operate
More informationEnbridge Gas Transmission and Midstream and Enbridge Liquid Pipelines (Express-Platte) Contractor Covered Task List Last updated 8/30/2018
001 Provide Security for Pipeline Facilities 195.436 Oral 003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 Oral
More informationEnLink Midstream Contractor Covered Task List Last updated 11/8/2017
003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 005 Repair Breakout Tank Overfill Protective Devices 195.428
More informationHoward Midstream Energy Partners LLC Contractor Covered Task List Last updated 10/11/2013
001 Provide Security for Pipeline Facilities 195.436 Oral 003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 005
More informationEpic Consolidated Operations LLC Contractor Covered Task List Last updated 9/6/2018
003 Test Breakout Tank Overfill Protective 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective 195.428 Oral 005 Repair Breakout Tank Overfill Protective 195.428 006 Inspection of Breakout
More informationNoble Energy Contractor Covered Task List Last updated 2/20/2019
003 Test Breakout Tank Overfill Protective Devices 195.428 Oral 004 Inspect and Calibrate Breakout Tank Overfill Protective Devices 195.428 005 Repair Breakout Tank Overfill Protective Devices 195.428
More informationBlack Hills Energy Contractor Covered Task List Last updated 10/10/2018
007 Operate Valves 103 Non-destructive Testing (Other than testing of welds) -- Mag Particle 201 Abnormal Operating Conditions Related to Welding on Pipelines 195.452(h) 192.225 192.227 192.715 192.717
More informationAppendix B Kinder Morgan Operator Qualification Program List of Covered Tasks Hazardous Liquid Pipelines Part 195 revised 8/24/2018
Abnormal Operating Conditions Outside of 101.01 Room Abnormal Operating Conditions Inside of 101.02 Room 102.01 Measure Structure-to-Soil Potentials 102.02 Advanced Cathodic Testing 102.03 Active Corrosion/MIC
More informationAppendix B Kinder Morgan Operator Qualification Program List of Covered Tasks Hazardous Liquid Pipelines Part 195 revised 12/12/2017
Abnormal Operating Conditions Outside of 101.01 Room Abnormal Operating Conditions Inside of 101.02 Room 102.01 Measure Structure-to-Soil Potentials 102.02 Advanced Cathodic Testing 102.03 Active Corrosion/MIC
More informationAppendix A Kinder Morgan Operator Qualification Program List of Covered Tasks - Natural Gas - Part 192 Revised 12/13/2017
01.01.01 Abnormal Operating Conditions (AOC) - Outside of Room 01.01.02 Abnormal Operating Conditions (AOC) - Inside of Room (new task effective 1/1/2018) 02.01.01 Gas Detection & Alarm System Maintenance
More informationASMECourseCatalog.
ASMECourseCatalog www.energyu.org www.midwestenergy.org ASME Abnormal Operating Conditions... 6 ASME GAS01 Hazards of Natural Gas and Prevention of Accidental Ignition... 6 ASME 0001 Measure Structure-to-Electrolyte
More informationCOVERED TASK Conduct Cathodic Protection Surveys 1 DESCRIPTION ELEMENTS OF TASK 4 PART QUESTION NOTES ABNORMAL OPERATING CONDITIONS
COVERED Conduct Cathodic Protection Surveys 1 Annual surveys are conducted for each operator s pipeline system that is under cathodic protection to ensure that the protection is adequate. This task is
More informationFlorida City Gas Contractor Covered Task List
001A Abandonment and deactivation of facilities 192.727 001B 001C 001SUBA Abandonment and deactivation of facilities (service lines not in use) Abandonment and deactivation of facilities (service lines
More informationOperator Qualification (OQ) Report
AOCF 66102/67107 Abnormal Operating Conditions Field for Natural Gas and Hazardous Liquids 5/15/2014 5/15/2017 AOCG 67107 Abnormal Operating Conditions for Natural Gas 5/16/2014 5/16/2017 TM001 66101 02
More informationPIPELINE CORROSION CONTROL
NCCER 13614 Progress Blvd, Alachua, Florida 32615 Phone: (888) 622-3720 E-mail: info@nccer.org PIPELINE CORROSION CONTROL Competencies / Objectives Level One MODULE 66101-02 INTRODUCTION TO THE PIPELINE
More informationPIGGING PRODUCTS. Capex supply. PIG LAUNCHER and RECEIVER
PIGGING PRODUCTS Capex supply PIG LAUNCHER and RECEIVER Before Cleaning After Cleaning TYPES OF PIGS DISPLACEMENT AND BATCHING PIGS AND PIG WITH BLADES (FOR CLEANING) 2 to 6 3 and 4 PIG with blades 5 to
More informationPHMSA Office of Pipeline Safety Dave Mulligan Western Region
PHMSA Office of Pipeline Safety Dave Mulligan Western Region Chevron Pipeline Releases Salt Lake City, Utah June 11, 2010 & December 1, 2011 Dave Mulligan U.S. Department of Transportation (US DOT) Pipeline
More informationNew UST Installation Inspection Checklist
Nebraska State Fire Marshal Fuels Division - FLST Section 246 South 14 TH Street - Lincoln, NE 68508-1804 (402) 471-9466 New UST Installation Inspection Checklist (Petroleum or Hazardous Substances) Inspection
More informationHDPE FUSIBLE VALVES EXPECT INNOVATION
AVK HDPE FUSIBLE VALVES HDPE FUSIBLE VALVES EXPECT INNOVATION AVK HDPE VALVES SERIES 89 FUSIBLE BUTTERFLY VALVE Series 89 fusible butterfly valves are designed for quick, direct heat butt-fusion or electrofusion
More informationCONTENTS. Foreword...iii. 1. Introduction...1
Installation of Aboveground Storage Systems for Motor-Vehicle Fueling CONTENTS Foreword...iii SECTIONS 1. Introduction...1 1.1 Background...1 1.2 Purpose...1 1.3 Scope...1 1.4 Source...1 1.5 Use of PEI/RP100...1
More informationThis article discusses a tank
CASE HISTORY Hot Oil Aboveground Storage Tank Bottom Corrosion Failure and Cathodic Protection Upgrade Part 2 KEVIN C. GARRITY AND PHILIP D. SIMON, CC Technologies, Inc. Several types of anode installations
More informationPipe Support The Fast, Economical Solution for Low Pressure Pipeline Repair
CLOCK SPRING Pipe Support The Fast, Economical Solution for Low Pressure Pipeline Repair 3 x 18 repairs were made in support locations. The Pipe could not be raised so blocks were inserted and the supports
More informationMonthly Checklist For Depot
Monthly Checklist For Depot ANNEXURE 1.L(iv) TANK FARM Notes : i. The scope covers piping, valve & fittings, general housekeeping, pumps & motors, effluent management, fire protection and security within
More informationInspector's Initials: Tank Owner or Agent Signature: Title: Date:
STATE OF TENNESSEE DEPARTMENT OF ENVIRONMENT AND CONSERVATION DIVISION OF UNDERGROUND STORAGE TANKS 4 TH Floor, L & C Tower 401 Church Street Nashville, TN 37243-1541 UST OPERATIONS INSPECTION Mo /Day
More informationPROCEDURE EXTRUDED HOT TAP & LINE STOP TEES DESIGN & MANUFACTURING VALIDATION
6534 Petropark Dr. Houston, TX 77041 USA Tel: +1 713-937-6193 Fax: +1 713-937-8695 www.uni-forge.com PROCEDURE EXTRUDED HOT TAP & LINE STOP TEES DESIGN & MANUFACTURING VALIDATION Prepared by: Approved
More informationMonitoring Cathodic Protection of Natural Gas Pipelines
Monitoring Cathodic Protection of Natural Gas Pipelines Period #8 Basic Corrosion Course 2017 February 21-23, 2017 Steve Glover - Vectren 0 Chapter Objective: Introduction Reasons to monitor What to monitor
More informationCathodic Protection for AST s. Why is Cathodic Protection Important?
Cathodic Protection for AST s Presented by: James T. Lary Corrpro Companies, inc. 1055 West Smith Road Medina, Ohio 44256 jlary@corrpro.com 330-241-6615 Why is Cathodic Protection Important? Preserve Assets
More informationThis publication is copyrighted and intended for the sole use of General Industries - 07/07/2016
AQUASWEEP JUNE 2009 INSTALLATION INSTRUCTIONS FOR AQUASWEEP UNDERGROUND OIL WATER SEPARATORS PREFACE i. Install the AquaSweep Oil Water Separator using personnel who have knowledge and experience in procedures
More informationINSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER SAMPLE / INJECTION PUMP
INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER SAMPLE / INJECTION PUMP MODEL SSO-9MED DRAWING NUMBERS AD243DI AD243DK AD243DK.K1 MANUAL NUMBER IOM-175 REVISION Rev. B, 3/21/2017 TABLE OF CONTENTS
More informationPEI/RP Recommended Practices for Installation of Bulk Storage Plants
PEI/RP800-08 Recommended Practices for Installation of Bulk Storage Plants Recommended Practices for Installation of Bulk Storage Plants CONTENTS Foreword...iii. SECTIONS 1. Introduction Page 1.1 Background...1
More informationINSTALLATION INSTRUCTIONS
R913 FRP COMPOSITE STEEL UNDERGROUND STORAGE TANKS INSTALLATION INSTRUCTIONS February 2017 1.0 EXCAVATION AND BEDDING 1.1 The bottom of the excavation shall be covered with a minimum of 12 inches (305
More informationAsset Protection Cathodic Protection Testing of Insulating Joints. Work Instruction No.:
Asset Protection Cathodic Protection Testing of Insulating Joints Approved by: Manager Pipeline Standards 1 PURPOSE This work instruction describes the requirements and process for testing the integrity
More informationAn Introduction to Constructing and Maintaining Cathodic Protection Systems
An Introduction to Constructing and Maintaining Cathodic Protection Systems Course No: T02-009 Credit: 2 PDH J. Paul Guyer, P.E., R.A., Fellow ASCE, Fellow AEI Continuing Education and Development, Inc.
More informationANNUAL UST SYSTEM INSPECTION CHECKLIST
APPENDIX A-3: SAMPLE FORM FOR ANNUAL UNDERGROUND STORAGE SYSTEM INSPECTION CHECKLIST Page 1 ANNUAL UST SYSTEM INSPECTION CHECKLIST Facility ID# Facility Name/Address Qualified Technician Signature Date
More informationINSTALLATION, OPERATION, & MAINTENANCE MANUAL Models # MM-30, MM-30HT, MM-50, MM-50HT, & MM-50 EXL with Special HP Tool and Special HP EXL Tool
INSTALLATION, OPERATION, & MAINTENANCE MANUAL Models # MM-30, MM-30HT, MM-50, MM-50HT, & MM-50 EXL with Special HP Tool and Special HP EXL Tool INSTALLATION INSTRUCTIONS FOR THE MODEL MM-30 & MODEL MM-50
More informationGUIDELINE FOR GLOVEBOXES THIRD EDITION AGS-G001 February 2007
GUIDELINE FOR GLOVEBOXES THIRD EDITION AGS-G001 February 2007 AMERICAN GLOVEBOX SOCIETY STANDARDS DEVELOPMENT COMMITTEE All Rights Reserved Copyright 2007 No portion may be duplicated without written consent
More informationCASE STUDY ON PIPELINE UNDER-PROTECTION ALONG WITH MITIGATION METHODS. Vipul Vilas Sawant. Mahanagar Gas Ltd, Mumbai, India
Paper No. CAP34 CASE STUDY ON PIPELINE UNDER-PROTECTION ALONG WITH MITIGATION METHODS Vipul Vilas Sawant Mahanagar Gas Ltd, Mumbai, India vsawant@mahanagargas. com ABSTRACT Mahanagar Gas Ltd is a City
More informationNo Infrared Refrigerant Leak Detector
No. 22791 Infrared Refrigerant Leak Detector Operator s Manual Product Description The Robinair No. 22791 uses infrared optics to create a refrigerant leak detector that combines sensitivity, speed, battery
More informationPENNSYLVANIA ABOVE GROUND STORAGE TANKS
PENNSYLVANIA ABOVE GROUND STORAGE TANKS GZA GeoEnvironmental Inc. by Jeffrey Knepper, LRS, CPG July 27, 2017 PA CODE Chapter 245. Administration of the Storage Tank & Spill Prevention Program AST Definition
More informationThe Implementation of a Storage Facility Inspection Program. Presented By: John R. Rueckel PCA Engineering, Inc.
The Implementation of a Storage Facility Inspection Program Presented By: John R. Rueckel PCA Engineering, Inc. Storage Facility Inspection Why implement an inspection program? Regulatory Requirements
More information7. UST Piping Corrosion Protection. NCDENR Division of Waste Management Underground Storage Tank Section
7. UST Piping Corrosion Protection NCDENR Division of Waste Management Underground Storage Tank Section 1 Where piping connects to tank Piping Corrosion Protection 2 Main run of piping 3 Where piping connects
More informationRolls -Royce M250--C47M OPERATION AND MAINTENANCE
TABLE 603 Inspection Checksheet Owner Date A/C Make/Model S/N Reg No. TSN Engine S/N TSN TSO This inspection checksheet is to be used when performing scheduled inspections. This form may be locally reproduced
More informationFINAL REPORT CATHODIC PROTECTION EVALUATION. 42-Inch Water Transmission Pipeline Contract 1 Station 0+00 to South Texas Water Authority
FINAL REPORT CATHODIC PROTECTION EVALUATION 42-Inch Water Transmission Pipeline Contract 1 Station 0+00 to 50+00 South Texas Water Authority Prepared for: South Texas Water Authority P.O. Box 1701 Kingsville,
More informationOil & Gas Custody Transfer Data Sheet
Date Company Name Location / Lease Name Contact Name Contact Email General Information 1. Will the unit be delivering to a pipline? If what is the pipline pressure? Pressure 2. Will the unit be receiving
More informationApplication for Permit to Install Underground Storage Tanks (Petroleum or Hazardous Substances) 1. Owner Information 2. Installation Site Information
Papillion/La Vista Fire Marshal s Office Fuels Division FLST Section 146 rth Adams Street Papillion, NE 68046 (402) 829-1398 Application for Permit to Install Underground Storage Tanks (Petroleum or Hazardous
More informationHighway Crossings - Cased or Uncased
Highway Crossings - Cased or Uncased Maryland Quality Initiative Annual Conference Baltimore Convention Center Baltimore, Maryland Steve Nanney PHMSA Office of Pipeline Safety January 31, 2013-1 - PHMSA
More informationPIPELINE INSPECTION SURVEY QUESTIONNAIRE
ARKA PETROGAS PIPELINE PIPELINE INSPECTION SURVEY QUESTIONNAIRE Project: PipeLine Name: ARKALINE Proj. No.:.. Please complete questionnaire as accurate as possible. Phone: +98 21-65611626 Fax: +98 21-65611627
More informationSECTION FACILITY FUEL - NATURAL GAS PIPING AND SYSTEMS
SECTION 23 11 23 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Fuel Pipe and Pipe Fittings - General 2. Steel Pipe and Fittings, Above Grade 3. Steel Pipe and Fittings, Below Grade 4. Polyethylene
More informationProvides the perfect seal, protects flanges, valves and pipelines against corrosion whilst improving safety and reducing the risk of fire.
Provides the perfect seal, protects flanges, valves and pipelines against corrosion whilst improving safety and reducing the risk of fire. s are typically used on offshore installations, sea water environments,
More informationKENNEDY VALVE Plant and Industrial Group 1021 East Water Street Elmira, New York Telephone (607) Fax (607)
KENNEDY VALVE Plant and Industrial Group 1021 East Water Street Elmira, New York 14901 Telephone (607) 734-2211 Fax (607) 734-3288 INSTALLATION, OPERATION, AND MAINTENANCE MANUAL General ECCENTRIC PLUG
More informationCHAPTER 115 LEAK DETECTION AND REPAIR (LDAR) PROGRAM CHANGES
CHAPTER 115 LEAK DETECTION AND REPAIR (LDAR) PROGRAM CHANGES FOR ALL FOUR OZONE NONATTAINMENT AREAS:! Delay of repair beyond the next process unit shutdown is allowed if the component is isolated from
More informationPIPELINE. catalogue. Pipeline construc on and maintenance Products & Solu ons
PIPELINE catalogue Pipeline construc on and maintenance Products & Solu ons About us... Founded in 1993, as agent and distributor of world leader brands, in pipeline an -corrosion coa ng; such as Raychem.
More informationReport of the Pipeline Safety Department. Home Explosion January 2, Whispering Hollow Drive Oklahoma City, Oklahoma
BOB ANTHONY TODD HIETT DANA MURPHY Commissioner Commissioner Commissioner OKLAHOMA CORPORATION COMMISSION P.O. BOX 52000 OKLAHOMA CITY, OKLAHOMA 73152-2000 Transportation Division Pipeline Safety Department
More informationThe Gradient Control Mat (GCM)
The (GCM) Installation Instructions INTRODUCTION Most gradient control mats are designed and installed around above ground pipeline appurtenances to limit power frequency voltages. The Dairyland gradient
More informationHOT TAPPING & PLUGGING SOLUTIONS
HOT TAPPING & PLUGGING SOLUTIONS STOPPLE Plus System Combined with a LOCK-O-RING Plus completion plug, the STOPPLE Plus fitting reduces installation time, simplifies the setting process, and eliminates
More informationBroetje-Automation Company Standard Structural component specification for welded parts
Broetje-Automation Company Standard Table of Contents Application Area and Purpose 3 1 Structural components pursuant to DIN 1090 4 1.1 Structural component classification 4 1.1.1 Steel components < Strength
More informationTHE KEY RELATIONSHIPS BETWEEN FIRE CODES, NEW YORK AST REGULATIONS AND SPCC PLANS
THE KEY RELATIONSHIPS BETWEEN FIRE CODES, NEW YORK AST REGULATIONS AND SPCC PLANS Presented by: Joyce A. Rizzo President JD2 Environmental, Inc. 800 East Washington Street West Chester, PA 19380 www.jd2env.com
More informationNYSDEC CBS Compliance Requirements
NYSDEC CBS Compliance Requirements Peter J. Petriccione, P.E. H2M - Water September 24, 2015 Introduction Definition of a Hazardous Substance and a Chemical Bulk Storage Facility Design Requirements of
More informationGF Piping Systems. SurTap System Operation with VersaTap Fittings Manual
GF Piping Systems SurTap System Operation with VersaTap Fittings Manual Thank you for selecting Georg Fischer Central Plastics products. GFCP strives to deliver the best technology and materials combined
More informationBiogas safety control equipment
Biogas safety control equipment As environmental concerns and energy efficiency are increasing, efficient economical and safe gas control systems become an increasingly important part of operating the
More informationRosemount 402 and 402VP
Rosemount 402 and 402VP Contacting Conductivity Sensors Instruction Manual LIQ-MAN-402 Rev. M May 2017 hasgkas Essential Instructions Read this page before proceeding! Emerson designs, manufactures and
More informationReport No.: Name of Ship: Plans referred during Initial Survey:
Report on the Surveys Concerning International Oil Pollution Prevention Certificate Part 7 Survey of installation for discharges from cargo spaces Initial/ Annual/ Intermediate/ Renewal/ Change of Flag
More informationDONKIN ASSET PROTECTION SYSTEM WARRANTY UP TO 20 YEARS* DONKIN ASSET PROTECTION SYSTEM
DONKIN ASSET PROTECTION SYSTEM WARRANTY UP TO 20 YEARS* DONKIN ASSET PROTECTION SYSTEM THE DONKIN ASSET PROTECTION SYSTEM FOR VALVES As part of AVK s commitment to provide our customers with solutions,
More informationFISC Puget Sound Manchester Fuel Department. Maintenance, Leak Detection in Large Underground Storage Tanks. Glenn E. Schmitt, P.E.
FISC Puget Sound Manchester Fuel Department Glenn E. Schmitt, P.E. Environmental Director Fleet and Industrial Supply Center Puget Sound Maintenance, Leak Detection in Large Underground Storage Tanks Ready.
More informationTest Stations and Pipe-to-Soil Potential Measurements
Test Stations and Pipe-to-Soil Potential Measurements Period #7 Practical Applications Course 2017 Mark James NACE CP II #5619, NACE CIP I #37041 1 Introduction Test Stations Wire Connection to Pipe Pipe-to-Soil
More informationStation 130 (Maple) Compressor Upgrade Project
Station 130 (Maple) Compressor Upgrade Project Application August 2012 Supplied to: The Secretary National Energy Board 444 7th Avenue SW Calgary, Alberta T2P 0X8 TransCanada Pipelines Limited APPENDIX
More information3-20 2FII & Groundhog Bonded Seat Butterfly Valve. Operation and Maintenance Manual. Job Name: Contractor: Date:
3-20 2FII & Groundhog Bonded Seat Butterfly Valve Operation and Maintenance Manual Job Name: Contractor: Date: Document #:3202FIIGD Revision Date: 1/10/11 SAFETY MESSAGES All safety messages in the instructions
More informationLACT MEASUREMENT. Total Head = Or PSI = S.G. 2.31
LACT MEASUREMENT Prepared By: Ken A. Steward. P.E. Linco-Electromatic, Inc. 4580 West Wall Street Midland, Texas 79703 The Operation of L.A.C.T. Units The simplest approach to the understanding of the
More informationAtmos Energy DOT Report-Distribution Leaks Cause of Leak WTX LA MS CO KS KY M-TX TN VA Total
Atmos Energy 2017 2017 DOT Report-Distribution Leaks Cause of Leak WTX LA MS CO KS KY M-TX TN VA Total CORROSION Hazardous Main 61 10 24 13 15 5 148 2 1 279 Non-Hazardous Main 160 156 93 46 155 64 728
More informationCENTRIFUGAL CHILLER. Lubrication System Pull oil sample for spectroscopic analysis.
CENTRIFUGAL CHILLER Annual Inspection Refrigerant Circuit Check and record refrigerant level Inspect for leak results Calculate refrigerant lass and report to the customer. Repair minor leaks as required
More informationProcessing Plant Enters. the Pipeline World. A Case Study of a Chemically Welded Anomaly Repair. By Randy Vaughn. R&F Pipecon Resources
Processing Plant Enters the Pipeline World A Case Study of a Chemically Welded Anomaly Repair By Randy Vaughn R&F Pipecon Resources Introduction A processing plant entered into the pipeline industry in
More informationWater Connection Repair Method and Techniques
Water Connection Repair Method and Techniques LINE LOCATES APWA Colour Codes Representatives from utility companies can field locate their lines if required. Excavation Ensure excavation is on the opposite
More informationOfficial Journal of the European Union L 298/39
16.11.2011 Official Journal of the European Union L 298/39 B3 6.8 Bearings 1 2 2 1 Purpose of bearings, loads, material, construction; Types of bearings and their application. 6.9 Transmissions 1 2 2 1
More informationSentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter
GE Measurement & Control Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter Applications The Sentinel flowmeter is a complete ultrasonic flowmeter system for the measurement of natural gas
More informationIgnition energy enough for igniting the mixture is available, such as sparkles generated by friction and impaction, electric arc or hot surfaces.
Elementary knowledge of safety and explosion protection 1.1 Characteristics of explosion A phenomenon, in which substances are converted from one state into another and massive energy and sounds are instantaneously
More informationSentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features
Applications The Sentinel flowmeter is a complete ultrasonic flowmeter system for the measurement of natural gas flow applications such as: Custody transfer Transmission and distribution Underground storage
More informationTechnical Offer. Antek Model 6200 Analyzer Determine Total Sulfur and Total Nitrogen in a single analyzer
Technical Offer Antek Model 6200 Analyzer 2015.4 Determine Total Sulfur and Total Nitrogen in a single analyzer Meet sulfur regulations and control your process with continuous sulfur and/or nitrogen measurements
More informationAUTOMOTIVE TECHNOLOGY 41 COURSE SYLLABUS
AUTOMOTIVE TECHNOLOGY 41 COURSE SYLLABUS Course Description: Recommended: AT1 or pass the Auto Tech 1 Placement Test. Principles of engine rebuilding, includes diagnosis, removing, disassembly, cleaning,
More informationPIPELINE INTEGRITY CONFERENCE BHR GROUP 5th-7th NOVEMBER 2008 SCHIPOL, THE NETHERLANDS PIPPELINE IN INDIA
PIPELINE INTEGRITY CONFERENCE BHR GROUP 5th-7th NOVEMBER 2008 SCHIPOL, THE NETHERLANDS REHABILITATING A MAJOR OIL PIPPELINE IN INDIA K.G. GUPTA, INDIAN OIL CORPORATION LTD, INDIA R. JOHN, BERRY PLASTICS
More informationRELIABLE AND EFFICIENT SYSTEMS
RELIABLE AND EFFICIENT SYSTEMS Systems must be leak-free as possible All systems leak Piping materials are slightly porous Very small leaks are not detectable and do not affect system efficiency Some systems
More informationLorri Grainawi Steel Tank Institute. PA NISTM April 25, 2013 Harrisburg, PA
Lorri Grainawi Steel Tank Institute PA NISTM April 25, 2013 Harrisburg, PA PEI/RP1200-12 ------------------------------------------------------ 1. Introduction 2. Definitions 3. Safety 4. Tank Secondary
More informationINSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER AUTOMATIC INSERTION PROBE
INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER AUTOMATIC INSERTION PROBE MODELS AIP-1 AIP-2 DRAWING NUMBERS AD198CA AD198CM AD198CO AD198DK.1 AD455BG AD455BO AD455EO MANUAL NUMBER IOM-006 REVISION
More informationMUELLER GAS. Shur StopTM Unit 812 PE Line Stopping. System 8" 12" SDR Reliable Connections. General Information 2
operating Instructions manual MUELLER GAS TAble of contents PAGE TM Unit 812 PE Line Stopping General Information 2 Equipment, Parts and Dimensions 3-5 Operating Instructions 6-12 Troubleshooting and Storage
More informationHave you previously been a supplier member? Yes No If yes, most recent year:
International Liquid Terminals Association 1005 N. Glebe Road, Suite 600 Arlington, VA 22201 Phone: 703-875-2011 Fax: 703-875-2018 Email: info@ilta.org Website: www.ilta.org SUPPLIER MEMBER APPLICATION
More information7. Protection System Testing
MANUAL FOR INSTALLATION AND MONITORING OF UNDERGROUND STORAGE TANKS WITH FACTORY INSTALLED ANODES 1. SCOPE Manufactured by: Granby Industries 1020 André-Liné Granby, Québec, Canada, J2J 1J9. Telephone:
More informationSECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY
SECTION 230533 - PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pressure gages. 2. Pressure gage taps. 3. Thermometers. 4. Thermometer supports. 5. Test plugs. 6. Static pressure
More informationFUNDAMENTALS OF INSERTION TURBINE METERS Les Bottoms Thermo Electron Corporation, Flow Systems
FUNDAMENTALS OF INSERTION TURBINE METERS Les Bottoms Thermo Electron Corporation, Flow Systems 9303 W. Sam Houston Parkway, Houston, TX 77099 INTRODUCTION The insertion turbine meter is well suited for
More informationMass Tank Inspection Services, LLC 29 Abbey Lane Middleboro, MA masstankinspection.com
June 18, 2018 Mrs. Nancy Cole Administrator Village of Eidelweiss 1680 Conway RD Madison, NH 03849 Mass Tank Inspection Services, LLC 29 Abbey Lane Middleboro, MA 02346 508-947-8826 masstankinspection.com
More informationGAS DISTRIBUTION PRODUCTS METER RISERS
GAS DISTRIBUTION PRODUCTS METER RISERS INDUSTRIES ABOUT US THE ULTIMATE CONNECTION Our Company Continental Industries, headquartered in Tulsa, Oklahoma, was formed in 1958 and is today a leading manufacturer
More informationBaumann Sanitary Diaphragm Angle and Inline Control Valve
Instruction Manual 84000 Valve Baumann 84000 Sanitary Diaphragm Angle and Inline Control Valve Contents Introduction... 1 Scope of Manual... 1 Safety Precautions... 2 Maintenance... 2 Flow Direction...
More informationCOSASCO TWO-INCH SYSTEM
COSASCO TWO-INCH SYSTEM INSTALLATION, OPERATION, & MAINTENANCE MANUAL SAND PROBES Rohrback Cosasco Systems 11841 East Smith Ave. Santa Fe Springs, CA 90670 Tel: (1) 562-949-0123 Fax: (1) 562-949-3065 E-mail:
More information