CATALOGUE

Size: px
Start display at page:

Download "CATALOGUE"

Transcription

1

2

3 Vemer offers to the Electrical Industry a wide range of products able to meet all the requirements of the modern installer. The digital programmable thermostats, time switches, measurement instruments, heat regulators and all the other Vemer products ensure maximum quality and functionality that only more than twenty years of experience can guarantee. ISO 9001 Certified Quality System

4 CLIMATE CONTROL TIME MANAGEMENT GAS AND SAFETY Digital programmable thermostats Mechanical time switches Gas detectors Staircase light switches Electronic thermostats Digital time switches Gas safety set Astronomical twilight switches Solenoid valves for gas Mechanical thermostats Twilight switches Emergency lamps Humidistats Twilight switches Buzzer and bells Accessories Hour meters Lights indicators and battery chargers

5 MEASUREMENT AND CONTROL HEAT REGULATION INSULATORS AND BUSBAR SUPPORTS ACCESSORIES Digital meters Digital thermometers Insulators Fairleads Network analyzers Analog heat regulators Spray - Fairleads Energy meters Digital heat regulators Busbar Current transformers and shunt Refrigeration regulators Gsm communication interfaces Digital humidity and pressure regulators Control relays Probes Level switches and Control panels pumps

6

7 INSULATORS AND BUSBAR SUPPORTS INSULATORS 8 BUSBAR SUPPORTS 22 CLIMATE CONTROL TIME MANAGEMENT GAS AND SAFETY MEASUREMENT AND CONTROL HEAT REGULATION INSULATORS AND BUSBAR SUPPORTS ACCESSORIES

8 Insulators TECHNICAL GUIDE The design of an electric system or part of it implies the choice of the structure as well as the elements it consists of. Among these, insulators play a fundamental role in reducing the risks caused by electrical stress to acceptable values. There are two types of fundamental parameters to identify an insulator: electrical and mechanical parameters. Electrical parameters Nominal design voltage Nominal insulation voltage Mechanical parameter Ultimate flexural value When design bar supporting systems, the electrodynamic efforts that are consequent to the passage of current must be taken into consideration. In particular, the greatest efforts on which the related insulating supports need to be proportioned, are those due to short circuit currents. The nomograms below allow to identify the ultimate flexural value (which ensures a degree of safety higher than or equal to 2.5) of the bar system, thus enable to select the most suitable insulator support. INSULATORS AND BUSBAR SUPPORTS ELECTRODYNAMIC EFFORTS BETWEEN LEADS Nomogram 1 Determination of the stress F by unit of length data required: I = short circuit current D = distance between phases Example: Icc = 15 ka (in AC) D = 7 cm result from the nomogram: F 150 dan/m 8

9 Insulators TECHNICAL GUIDE ELECTRODYNAMIC EFFORTS BETWEEN LEADS Nomogram 2 Determination of the distance L between supports data required: F = stress by unit of length (obtained from the previous nomogram) W = module of longitudinal and transversal resistance of the bars according to X-X or Y-Y, respectively (obtainable on the basis of the dimensions and the position of the bar, whether horizontal or vertical) Example: F 150 dan/m W = 0.5 cm 3 (50 x 8 vertical position) result from nomogram: L 0.7 m Nomogram 3 Determination of the ultimate flexure value P data required: F = stress by unit of length L = distance between supports (obtained from the previous nomogram) Example: F 150 dan/m L 0.7 m (vertical position) result from nonogram: P 500 dan (for bar system in vertical position) Once the P value has been defined, it is possible to identify the most suitable insulator by consulting in the special tables of each single article (flexure columns) a value that is higher than or similar to the one obtained with Nomogram 3 VERTICAL HORIZONTAL COPPER ALU VERTICAL HORIZONTAL 9 CLIMATE CONTROL TIME MANAGEMENT GAS AND SAFETY MEASUREMENT AND CONTROL HEAT REGULATION INSULATORS AND BUSBAR SUPPORTS ACCESSORIES

10 Petticoat insulators CI SERIES TECHNICAL CHARACTERISTICS Series of insulators designed to be used as supports or spacers of electrically active parts such as bars or leads used to create LV and MV electric systems. Their typical bell shape makes them particularly suitable to be used in environments with a high percentage of humidity or a high degree of fine suspended dust. Indeed, the profile structure provides a creepage distance that satisfies the rated voltage as well as humidity runoff and the non continuous formation of dust deposits. Made of polyester resin with the addition of glass fibres, they guarantee a high mechanical and electrical resistance over time. On request the non-absorbing and highly self-extinguishing material used can be provided in its antiacid version, which is particularly suitable for use in contaminated atmospheres. On both resting sides the insulators feature a brass threaded female insert that, by means of different types of special headless screws, allows the coupling with the parts concerned. Colour: red RAL-3002 (a different colour can be provided on request in case of large orders) Arc resistance: > 180 s - ASTM D-495 Material: self-extinguishing in class V0 in according to the UL-94 standard Operating temperature: -40 C +130 C Water absorption: < 0.2% - ASTM D-570 For the fastening please refer to the section GV series accessories DIMENSIONS Modular CI series CI format series Ø D Ø B Ø B E A E Ø B Ø C A Ø C 10

11 SELECTABLE ELEMENTS SELECTABLE ELEMENTS MODULAR SERIES M8 insert M10 insert M12 insert Minimum Minimum Tensile Compressive Torsion Flexural surface internal Operating flashover flashover voltage Height Code Model voltage AC (kv) voltage AC (kv) DC / AC (V) (A) (C) (D) (E) SA CI SA CI SA CI SA CI SA CI M16 insert SA CI SA CI SA CI Ultimate tolerance ±10% 1 dan = 10 N INSULATORS AND BUSBAR SUPPORTS SELECTABLE ELEMENTS FORMAT SERIES M12 insert Maximum operating voltage (kv) Max rated voltage at industrial frequency (kv) Max rated pulse voltaged (kv) Code Model Rated voltage (kv) Height (A) (C) (No. of elements) SA CI SA CI SA CI SA CI SA CI M16 insert SA CI SA CI SA CI SA CI SA CI Ultimate tolerance ±10% 1 dan = 10 N 11 CLIMATE CONTROL TIME MANAGEMENT GAS AND SAFETY MEASUREMENT AND CONTROL HEAT REGULATION INSULATORS AND BUSBAR SUPPORTS ACCESSORIES

12 Load-bearing and spacer insulators DP SERIES TECHNICAL CHARACTERISTICS Series of insulators designed to be used as supports or spacers of electrically active parts such as the bars used to create panels. Made of polyester resin with the addition of glass fibres, they guarantee a high mechanical and electrical resistance over time. On request the non-absorbing and highly self-extinguishing material used can be provided in its antiacid version, which is particularly suitable for use in contaminated atmospheres. On both resting sides the insulators feature a brass or white iron zincate threaded female insert that, by means of different types of special headless screws, allows the coupling with the parts concerned, while the central part features a band for the fastening, depending on the model (octagonal or hexagonal). Colour: red RAL-3002 (a different colour can be provided on request in case of large orders) Arc resistance: > 180 s - ASTM D-495 Material: self-extinguishing in class V0 (1.6 mm) according to the UL-94 standard Operating temperature: - 40 C +130 C Water absorption: < 0.2% - ASTM D-570 Tracking resistance: 3 W/min - ASTM D-2302 For the fastening please refer to the section GV series accessories DIMENSIONS Ø D Octagonal version E A E Ø B Ø C Hexagonal version 12

13 Spacer column insulators CP SERIES TECHNICAL CHARACTERISTICS Series of insulators designed to be used as supports or spacers of electrically active parts such as the bars used to create panels. Made of polyester resin with the addition of glass fibres, they guarantee a high mechanical and electrical resistance over time. Furthermore, the material is non absorbing and highly self-estinguishing. On both resting sides the insulators feature a brass or white iron zincate threaded female insert that, by means of different types of special headless screws, allows the coupling with the parts concerned, while the lower part features a hexagonal band for the fastening. Colour: red RAL-3002 (a different colour can be provided on request in case of large orders) Arc resistance: > 180 s - ASTM D-495 Material: self-extinguishing in class V0 (1.6 mm) according to the UL-94 standard Operating temperature: -40 C +130 C Water absorption: < 0.2% - ASTM D-570 Tracking resistance: 3 W/min - ASTM D-2302 For the fastening please refer to the section GV series accessories DIMENSIONS diametro C A C Ø B 13 CLIMATE CONTROL TIME MANAGEMENT GAS AND SAFETY MEASUREMENT AND CONTROL HEAT REGULATION INSULATORS AND BUSBAR SUPPORTS ACCESSORIES

14 Load-bearing and spacer insulators SELECTABLE ELEMENTS M3 insert M4 insert M5 insert M6 insert M8 insert Tensile Compressive Flexural Max rated voltage at 50Hz for 1 min (kv) Min internal flashover voltage AC (kv) Operating voltage DC / AC (V) Code Model Type Height Width (A) (C) (D) (E) SA DP Hexagonal SA DP Octagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Octagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Octagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Octagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Octagonal SA DP Octagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Octagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal Ultimate tolerance ±10% 1 dan = 10 N 14

15 DP SERIES M10 insert M12 insert M16 insert Tensile Compressive Flexural Max rated voltage at 50Hz for 1 min (kv) Min internal flashover voltage AC (kv) Operating voltage DC / AC (V) Code Model Type Height Width (A) (C) (D) (E) SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Octagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Octagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Octagonal SA DP Hexagonal SA DP Hexagonal SA DP Octagonal SA DP Octagonal SA DP Hexagonal SA DP Hexagonal SA DP Octagonal SA DP Hexagonal SA DP Hexagonal SA DP Octagonal SA DP Octagonal Ultimate tolerance ±10% 1 dan = 10 N 15 CLIMATE CONTROL TIME MANAGEMENT GAS AND SAFETY MEASUREMENT AND CONTROL HEAT REGULATION INSULATORS AND BUSBAR SUPPORTS ACCESSORIES

16 Spacer column insulators SELECTABLE ELEMENTS M4 insert M5 insert M6 insert Tensile Flexural Max rated voltage at 50Hz for 1 min (kv) Min internal flashover voltage AC (kv) Operating voltage DC / AC (V) Diameter Height Code Model (A) (C) SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP Ultimate tolerance ±10% 1 dan = 10 N 16

17 CP SERIES M8 insert M10 insert M12 insert Tensile Flexural Max rated voltage at 50Hz for 1 min (kv) Min internal flashover voltage AC (kv) Operating voltage DC / AC (V) Diameter Height Code Model (A) (C) SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP Ultimate tolerance ±10% 1 dan = 10 N 17 CLIMATE CONTROL TIME MANAGEMENT GAS AND SAFETY MEASUREMENT AND CONTROL HEAT REGULATION INSULATORS AND BUSBAR SUPPORTS ACCESSORIES

18 Load-bearing and spacer insulators DP UL SERIES TECHNICAL CHARACTERISTICS Series of insulators designed to be used as supports or spacers of electrically active parts such as the bars used to create panels. Made of polyamide resin with the addition of glass fibres, they guarantee a high mechanical and electrical resistance over time. The material used is halogen free UL V0. On both resting sides the insulators feature a brass or white iron zincate threaded female insert that, by means of different types of special headless screws, allows the coupling with the parts concerned, while the central part features a band for the fastening, depending on the model (octagonal or hexagonal). Colour: black Arc resistance: > 180 s - ASTM D-495 Material: self-extinguishing in class V0 (1.6 mm) according to the UL-94 standard Operating temperature: - 40 C +130 C Water absorption: < 0.2% - ASTM D-570 Tracking resistance: 3 W/min - ASTM D-2302 For the fastening please refer to the section GV series accessories Halogen free DIMENSIONS Ø D Octagonal version E A E Ø B Ø C Hexagonal version 18

19 Spacer column insulators CP UL SERIES TECHNICAL CHARACTERISTICS Series of insulators designed to be used as supports or spacers of electrically active parts such as the bars used to create panels. Made of polyamide resin with the addition of glass fibres, they guarantee a high mechanical and electrical resistance over time. Furthermore, the material is non absorbing and highly self-estinguishing. The material used is halogen free UL V0. On both resting sides the insulators feature a brass or white iron zincate threaded female insert that, by means of different types of special headless screws, allows the coupling with the parts concerned, while the lower part features a hexagonal band for the fastening. Colour: black Arc resistance: > 180 s - ASTM D-495 The material used is halogen free UL V0 Material: self-extinguishing in class V0 (1.6 mm) according to the UL-94 standard Operating temperature: -40 C +130 C Water absorption: < 0.2% - ASTM D-570 Tracking resistance: 3 W/min - ASTM D-2302 For the fastening please refer to the section GV series accessories Halogen free DIMENSIONS diametro C A C Ø B 19 CLIMATE CONTROL TIME MANAGEMENT GAS AND SAFETY MEASUREMENT AND CONTROL HEAT REGULATION INSULATORS AND BUSBAR SUPPORTS ACCESSORIES

20 Load-bearing and spacer insulators SELECTABLE ELEMENTS M3 insert M4 insert M5 insert M6 insert M8 insert Tensile Compressive Flexural Max rated voltage at 50Hz for 1 min (kv) Min internal flashover voltage AC (kv) Operating voltage DC / AC (V) Code Model Type Height Width (A) (C) (D) (E) SA DP Hexagonal SA DP Octagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Octagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Octagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Octagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Octagonal SA DP Octagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Octagonal SA DP Hexagonal SA DP Hexagonal Ultimate tolerance ±10% 1 dan = 10 N 20

21 DP UL SERIES M10 insert M12 insert M16 insert Tensile Compressive Flexural Max rated voltage at 50Hz for 1 min (kv) Min internal flashover voltage AC (kv) Operating voltage DC / AC (V) Code Model Type Height Width (A) (C) (D) (E) SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Octagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Octagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Hexagonal SA DP Octagonal SA DP Octagonal SA DP Hexagonal SA DP Hexagonal SA DP Octagonal SA DP Octagonal Ultimate tolerance ±10% 1 dan = 10 N 21 CLIMATE CONTROL TIME MANAGEMENT GAS AND SAFETY MEASUREMENT AND CONTROL HEAT REGULATION INSULATORS AND BUSBAR SUPPORTS ACCESSORIES

22 Spacer column insulators SELECTABLE ELEMENTS M4 insert M5 insert M6 insert Tensile Flexural Max rated voltage at 50Hz for 1 min (kv) Min internal flashover voltage AC (kv) Operating voltage DC / AC (V) Diameter Height Code Model (A) (C) SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP Ultimate tolerance ±10% 1 dan = 10 N 22

23 CP UL SERIES M8 insert M10 insert M12 insert Tensile Flexural Max rated voltage at 50Hz for 1 min (kv) Min internal flashover voltage AC (kv) Operating voltage DC / AC (V) Diameter Height Code Model (A) (C) SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP SA CP Ultimate tolerance ±10% 1 dan = 10 N 23 CLIMATE CONTROL TIME MANAGEMENT GAS AND SAFETY MEASUREMENT AND CONTROL HEAT REGULATION INSULATORS AND BUSBAR SUPPORTS ACCESSORIES

24 Load-bearing insulators and spacer columns DPS/CPS SERIES TECHNICAL CHARACTERISTICS Series of insulators designed to be used as supports or spacers of electrically active parts such as the bars used to create panels. Made of polyester resin with the addition of glass fibres, they guarantee a high mechanical and electrical resistance over time. Furthermore, the material used is non absorbing and highly self-extinguishing. On both resting sides the insulators feature a brass or white iron zincate threaded female insert that, by means of different types of special headless screws, allows the coupling with the parts concerned. Thanks to the special shape of the metallic insert (which differs from the CP-DP series as it protrudes by 2 mm), they are used in those cases when a washer needs to be interposed to increase the contact surface. Colour: red RAL-3002 (a different colour can be provided on request in case of large orders) Arc resistance: > 180 s - ASTM D-495 Material: self-extinguishing in class VO (1.6 mm) according to the UL-94 standard Operating temperature: -40 C +130 C Water absorption: < 0.2% - ASTM D-570 Tracking resistance: 3 W/min - ASTM D-2302 For the fastening please refer to the section GV series accessories SELECTABLE ELEMENTS CPS SERIES SELECTABLE ELEMENTS DPS SERIES M5 insert Code Model Height Width SA CPS M6 insert Code Model Height Width SA DPS M6 insert SA CPS SA CPS SA CPS SA CPS M8 insert SA DPS M8 insert SA CPS SA CPS SA CPS SA CPS SA CPS M10 insert SA CPS M12 insert SA CPS

25 Tensioning insulators TEP SERIES TECHNICAL CHARACTERISTICS Series of insulators designed to be used as tensioning elements with electrically active parts such as leads used to create electric systems and their relevant support. Available in two versions: one complete with the terminal ring elements and the other without them. They are designed with opposing threads, a right one and a left one, and the span of the two rings (maximum opening and minimum closing) is approximately 80 mm. Made of polyester resin with the addition of glass fibres, they guarantee a high mechanical and electrical resistance over time. Furthermore, the material used is non absorbing and highly self-extinguishing. Colour: red RAL-3002 (a different colour can be provided on request in case of large orders) Arc resistance: > 180 s - ASTM D-495 Material: self-extinguishing in class VO according to with the UL-94 standard Operating temperature: -40 C +130 C Water absorption: 0.013% - ASTM D-570 TEP 1 TEP 2 C C A Ø B SELECTABLE ELEMENTS Ultimate tensile (da N) Min superficial flashover voltage AC (kv) Min internal flashover voltage AC (kv) Operating voltage DC / AC (kv) Dimensions Height Amin Amax Ø B C Code Model SA TEP M12 65 SA TEP / Ultimate tolerance ±10% 25 CLIMATE CONTROL TIME MANAGEMENT GAS AND SAFETY MEASUREMENT AND CONTROL HEAT REGULATION INSULATORS AND BUSBAR SUPPORTS ACCESSORIES

26 Bushing insulators IP SERIES TECHNICAL CHARACTERISTICS Series of bushing insulators designed to be used as elements of electrical connection between the internal and external parts of the equipment. Available in red and black, they differ for the terminal element for the electrical connection of the leads, which is a nut element. The insulator consists of two insulating parts, easily plugged together, made of polyester resin with glass fibres and locked by a rod that also acts as a conducting element between the parts, by means of two nuts. For models up to 80 A one of the nuts is integral with the rod and made of brass. For superior currents, rods and nuts are made of zinc coated soft iron. The particular construction of the insulating parts and the rod allows the leads (fastened to the rod by zincchromium plated steel nuts) to be connected and disconnected both by one part or the other of the bushing insulator without turn or unlock the insulator from the mounting. Standard colour: red RAL-3002 A different colour can be provided for large orders. Arc resistance: > 180 s - ASTM D-495 Material: self-extinguishing in class VO (1.6 mm) according to the UL-94 standard Operating temperature: -40 C +130 C Water absorption: < 0.2% - ASTM D-570 Tracking resistance: 3 W/min - ASTM D-2302 DIMENSIONS Normal IPN bushing insulator Drill gauge F E E Ø D Ø B A C Ø 1 Ø 2 SELECTABLE ELEMENTS Rated Operating current voltage Test Dimensions Code Model Material Colour capacity (A) (V) voltage (kv) A Ø B C Ø D E F Ø 1 Ø 2 SA IPN 025 Integral brass nut and pin red M SA IPN 050 Integral brass nut and pin red M SA IPN 080 Integral brass nut and pin red M SA IPN 120 Zinc coated soft iron red M SA IPN 200 Zinc coated soft iron red M SA IPN 300 Zinc coated soft iron red M SA IPN 450 Zinc coated soft iron red M

27 Accessories GV SERIES TECHNICAL CHARACTERISTICS Set of headless screws complete with nuts, flat and elastic washers. Finishing with sealed galvanic zincing. DIMENSIONS Ø F L Code Model Ø F thread Length L SA GV2506 M6 25 SA GV3006 M6 30 SA GV3008 M8 30 SA GV4008 M8 40 SA GV4010 M10 40 SA GV5012 M12 50 SA GV6016 M CLIMATE CONTROL TIME MANAGEMENT GAS AND SAFETY MEASUREMENT AND CONTROL HEAT REGULATION INSULATORS AND BUSBAR SUPPORTS ACCESSORIES

28 Busbar supports SPI SERIES TECHNICAL CHARACTERISTICS Series of insulators designed to be used as a busbar support element in three-phase systems and three-phase plus neutral systems. The series consists of two families, each divided into four different measurements dimensionally related to the sections of the bars, four for the three-phase system and four for the three-phase plus neutral system. The insulator consists of two crossbars on which socket slots are obtained whose width, which can be completed with a simple and patented system of rider spacers, allows the different bar sections to be adapted by always keeping the axle base constant between the phases. Everything is fitted with threaded shafts, washers and zinc coated nuts for fastening to the frame and the clamping of the two crossbars. Made of polyester resin with the addition of a high percentage of glass fibres, they guarantee a high electrodynamic resistance over time in case of faulty currents and an excellent performance in contaminated atmospheres. Colour: red RAL-3002 (a different colour can be provided on request in case of large orders) Arc resistance: > 120 s - ASTM D-495 Material: self-extinguishing in class VO (3.2 mm) according to the UL-94 standard Operating temperature: -40 C +130 C Water absorption: < 0.15% - UNI 4292 Tracking resistance: 300 W/min - ASTM D-2303 Dielectric rigidity: 12 kv/mm - UNI 4291 Shock resistance: 25 kj/m 2 - UNI 6062 Expansion coefficient: 2x10-5 C - UNI 6061 AC/DC operating voltage: 750/900 V Max rated voltage at 50 Hz for 1 min: 3 kv Max rated pulse voltage: 8 kv SELECTABLE ELEMENTS Three-phase system Three-phase system+neutral Bar dimensions Ultimate Busbar Code Model Code Model Phase Neutral supports size SA SPI 31 SA SPI 41 I 32x4-63x5 I 32x4-63 x I SA SPI 32 SA SPI 42 I 50x5-100x10 I 50x4-100x II I I 50x5-100x5 SA SPI 33 SA SPI 43 I 50x8-125x10 I 50x4-125x III I I 50x5-125x10 SA SPI 34 SA SPI 44 I 50x8-160x10 I 50x4-160x IV I I 50x5-160x10 I 50x4-160x Ultimate tolerance ±10% 1 dan = 10 N 28

29 DIMENSIONS B C D F A D Dimensions Code Model A B C D E F SA SPI SA SPI SA SPI SA SPI B C F D D E A Dimensions Code Model A B C D E F SA SPI SA SPI SA SPI B C F D D E A Dimensions Code Model A B C D E F SA SPI INSULATORS AND BUSBAR SUPPORTS Spacing slugs DIMENSIONS S Code Model Thickness S SA SB SA SB SA SB SA SB SA SB SA SB SA SB SA SB SA SB SA SB SA SB SA SB SA SB CLIMATE CONTROL TIME MANAGEMENT GAS AND SAFETY MEASUREMENT AND CONTROL HEAT REGULATION INSULATORS AND BUSBAR SUPPORTS ACCESSORIES

30 Busbar supports and spacers: one bar per phase SELECTABLE ELEMENTS Phase bar height Bar thickness Rated current (A) Symmetrical short circuit current between phases (ka) Phase Neutral* In Distance between phases Copper Aluminium * Three-phase+Neutral system 30

31 SPI SERIES Symmetrical short circuit current between phases (ka) Three-phase system Three-phase system+neutral Distance between supports L Busbar supports SPI31 6-SB 10 2 SPI41 8-SB 10 7 SPI31-1 SPI41 2-SB 10 6 SPI31 6-SB 10 2 SPI41 8-SB 10 7 SPI31-1 SPI41 2-SB 10 6 SPI31 6-SB 10 2 SPI41 8-SB 10 7 SPI31-1 SPI41 2-SB 10 6 SPI31 6-SB 10 2 SPI41 8-SB SPI31-1 SPI41 2-SB SPI32 12-SB 50 3 SPI42 12-SB 50+2-SB SPI32 12-SB 45 3 SPI42 12-SB 45+2-SB SPI32 12-SB 35 3 SPI42 12-SB 35+2-SB SPI32 12-SB 25 3 SPI42 12-SB 25+2-SB SPI32 12-SB 50 3 SPI42 12-SB 50+2-SB SPI32 12-SB 45 3 SPI42 12-SB 45+2-SB SPI32 12-SB 35 3 SPI42 12-SB 35+2-SB SPI32 12-SB 25 3 SPI42 12-SB 25+2-SB SPI32 12-SB 50 3 SPI42 12-SB 50+2-SB SPI32 12-SB 45 3 SPI42 12-SB 45+2-SB SPI32 12-SB 35 3 SPI42 12-SB 35+2-SB SPI32 12-SB 25 3 SPI42 12-SB 25+2-SB SPI32 12-SB 50 3 SPI42 12-SB 50+2-SB SPI32 12-SB 45 3 SPI42 12-SB 45+2-SB SPI32 12-SB 35 3 SPI42 12-SB 35+2-SB SPI32 12-SB 25 3 SPI42 12-SB 25+2-SB SPI33 12-SB SPI43 12-SB SB SPI33 12-SB SPI43 12-SB SB SPI33 12-SB SPI43 12-SB SB SPI33 12-SB SPI43 12-SB SB SPI33 12-SB SPI43 12-SB SB SPI33 12-SB SPI43 12-SB SB SPI33 12-SB SPI43 12-SB SB SPI33 12-SB SPI43 12-SB SB SPI33 12-SB SPI43 12-SB SB SPI33 12-SB SPI43 12-SB SB SPI34 12-SB SPI44 12-SB SB SPI34 12-SB SPI44 12-SB SB SPI34 12-SB SPI44 12-SB SB SPI34 12-SB SPI44 12-SB SB SPI34 12-SB SPI44 12-SB110+2-SB SPI34 12-SB SPI44 12-SB SB SPI34 12-SB SPI44 12-SB SB SPI34 12-SB SPI44 12-SB SB SPI34 12-SB SPI44 12-SB SB SPI34 12-SB SPI44 12-SB SB SPI34 12-SB SPI44 12-SB SB 50 8 Spacers Positioning diagram Busbar supports Spacers Positioning diagram 31 CLIMATE CONTROL TIME MANAGEMENT GAS AND SAFETY MEASUREMENT AND CONTROL HEAT REGULATION INSULATORS AND BUSBAR SUPPORTS ACCESSORIES

32 Busbar supports and spacers: two bars per phase SELECTABLE ELEMENTS Phase bar height Bar thickness Rated current (A) Phase Neutral* In Distance between phases Copper Aluminium * Three-phase+Neutral system 32

33 SPI SERIES Symmetrical short circuit current between phases (ka) Three-phase system Three-phase system+neutral Distance between supports L Busbar supports SPI 32 6-SB 50 4 SPI 42 6-SB 50+2-SB SPI 32 6-SB 50 4 SPI 42 6-SB 50+2-SB SPI 32 6-SB 50 4 SPI 42 6-SB 50+2-SB SPI 32 6-SB 50 4 SPI 42 6-SB 50+2-SB SPI 33 6-SB SB 75 5 SPI 43 8-SB SB SPI SB 60 5 SPI SB 60+2-SB SPI 33 6-SB SB 30 5 SPI 43 6-SB SB 30+2-SB SPI 33 6-SB SPI 43 6-SB SPI 33 6-SB SB 75 5 SPI 43 8-SB SB SPI SB 60 5 SPI SB 60+2-SB SPI 33 6-SB SB 30 5 SPI 43 6-SB SB 30+2-SB SPI 33 6-SB SPI 43 6-SB SPI 33 6-SB SB 75 5 SPI 43 8-SB SB SPI SB 60 5 SPI SB 60+2-SB SPI 33 6-SB SB 30 5 SPI 43 6-SB SB 30+2-SB SPI 33 6-SB SPI 43 6-SB SPI 33 6-SB SB 75 5 SPI 43 8-SB SB SPI SB 60 5 SPI SB 60+2-SB SPI 33 6-SB SB 30 5 SPI 43 6-SB SB 30+2-SB SPI 33 6-SB SPI 43 6-SB SPI 33 6-SB SB 30 5 SPI 43 6-SB SB 30+2-SB SPI 33 6-SB SPI 43 6-SB SPI 34 6-SB SB 75 5 SPI 44 8-SB SB SPI SB 60 5 SPI SB 60+2-SB SPI 34 6-SB SB 30 5 SPI 44 6-SB SB 30+2-SB SPI 34 6-SB SPI 44 6-SB SPI 34 6-SB SB 75 5 SPI 44 8-SB SB SPI SB 60 5 SPI SB 60+2-SB SPI 34 6-SB SB 30 5 SPI 44 6-SB SB 30+2-SB SPI 34 6-SB SPI 44 6-SB SPI 34 6-SB SB 75 5 SPI 44 8-SB SB SPI SB 60 5 SPI SB 60+2-SB SPI 34 6-SB SB 30 5 SPI 44 6-SB SB 30+2-SB SPI 34 6-SB SPI 44 6-SB SPI 34 6-SB SB 75 5 SPI 44 8-SB SB SPI SB 60 5 SPI SB 60+2-SB SPI 34 6-SB SB 30 5 SPI 44 6-SB SB 30+2-SB SPI 34 6-SB SPI 44 6-SB SPI 34 6-SB SB 30 5 SPI 44 6-SB SB 30+2-SB SPI 34 6-SB SPI 44 6-SB SPI 34 6-SB SPI 44 6-SB Spacers Positioning diagram Busbar supports Spacers Positioning diagram 33 CLIMATE CONTROL TIME MANAGEMENT GAS AND SAFETY MEASUREMENT AND CONTROL HEAT REGULATION INSULATORS AND BUSBAR SUPPORTS ACCESSORIES

34 Busbar supports SPACER POSITIONING DIAGRAMS THREE-PHASE SYSTEM THREE-PHASE + NEUTRAL SYSTEM SPI SERIES N 1 N 6 N 7 N 2 N 8 N 3 N 9 N 4 N 10 N 5 N 11 34

35 INSULATORS AND BUSBAR SUPPORTS 35 CLIMATE CONTROL TIME MANAGEMENT GAS AND SAFETY MEASUREMENT AND CONTROL HEAT REGULATION INSULATORS AND BUSBAR SUPPORTS ACCESSORIES

36 Progetto grafico: EN_MKCT0xx_201609

37

38 Vemer SpA Via Camp Lonc, 16 I Villapaiera - Feltre (BL) Phone Fax info@vemer.it

S R O T A L SU IN INSULATORS

S R O T A L SU IN INSULATORS INSULATORS INSULATORS LV INSULATORS & MV BUSHINGS BMC & SMC MOULDED PARTS CONTENTS 03 04 05 LV Insulators Material Data LV Insulators Type SK Color: Red LV Insulators Type SK 06 07 08 09 10 11 LV Insulators

More information

Product Datasheet. Cable TV Junction Box (Page 4)

Product Datasheet. Cable TV Junction Box (Page 4) JUNCTION BOX Product Datasheet Junction Box Bolted Type (Page 2) Cable TV Box (Page ) Cable TV Junction Box (Page 4) Telephone Box (Page 5) Telephone Junction Box (Page 6) GRP Junction Box Enclosures are

More information

Our Company. NyFlex INTERNATIONAL OUR MANUFACTURING RANGE OUR FORTH-COMING PRODUCTS U JIS-C2004 L JIS-C2005 JIS-C2006 E TRADERS

Our Company. NyFlex INTERNATIONAL OUR MANUFACTURING RANGE OUR FORTH-COMING PRODUCTS U JIS-C2004 L JIS-C2005 JIS-C2006 E TRADERS Our Company Nylex Group established in 1 and leading through excellence and innovation, the buzz word at Nylex We at Nylex are group of trained personnel with each one being updated in their respective

More information

Distribution Blocks & Bus-bar Solutions

Distribution Blocks & Bus-bar Solutions Distribution Blocks & Bus-bar Solutions Insulated Multi Laminate Flexible Copper Bus-bars Threaded Copper Bus-bars Solid Copper Bus-bars Bus-bar Insulators & Supports Insulated Flexible Copper Braided

More information

Product Datasheet. 2. GRP large rain canopy. 3. GRP door. 4. G.I Mounting plate. 5. G.I Gland plate. 6. EPDM rubber gasket

Product Datasheet. 2. GRP large rain canopy. 3. GRP door. 4. G.I Mounting plate. 5. G.I Gland plate. 6. EPDM rubber gasket POLYESTER ENCLOSURE SINGLE DOOR Product Datasheet GRP Single Door Enclosures are used for outdoor application with weatherproof and antistatic properties, finding their major application in the protection

More information

026-2 : 1996 CEB STANDARD

026-2 : 1996 CEB STANDARD 026-2 : 1996 CEB STANDARD COMPRESSION CONNECTORS & TERMINATIONS FOR OVERHEAD LINE CONDUCTORS CEYLON ELECTRICITY BOARD SRI LANKA CONTENTS 1. Scope 2 2. System Parameters 2 3. Service Conditions 2 4. Applicable

More information

ACCESSORIES FOR SZE2 CABINETS

ACCESSORIES FOR SZE2 CABINETS ZPAS 143 DOORS Doors Intended for use instead of front solid door or rear panel. Maximum door opening angle: 120 Sheet steel textured powder paint, light grey (RAL 7035), stiffened profiles, brown smoked

More information

VERONEX Cases MATERIAL PERFORMANCE CHARACTERISTICS. MECHANICAL PROPERTIES Units Test method Result. THERMAL PROPERTIES Units Test method Result

VERONEX Cases MATERIAL PERFORMANCE CHARACTERISTICS. MECHANICAL PROPERTIES Units Test method Result. THERMAL PROPERTIES Units Test method Result VERONEX Cases VERONEX is a breakthrough in plastic enclosure design, combining the versatility and functionality demanded by engineers, with the modern styling appreciated by their customers. The VERONEX

More information

GENERAL INDEX TR60. 6 YELLOW LINE Continuous Conductors. Max 5 Poles. 8 BLUE LINE Pre-Mounted Conductors TR85H5P. YELLOW LINE Continuous Conductors

GENERAL INDEX TR60. 6 YELLOW LINE Continuous Conductors. Max 5 Poles. 8 BLUE LINE Pre-Mounted Conductors TR85H5P. YELLOW LINE Continuous Conductors 2 Automation - Lift - Handling System GENERAL INDEX 2 DESCRIPTION 3 BUSBAR LINE VERSIONS LINE TYPE / AMPERAGE COVERAGE 5 TR60 40 A 50 A 60 A 70 A 100 A 140 A 160 A 200 A 320 A 6 YELLOW LINE Continuous

More information

CALEFFI. Manifolds in composite specifically designed for radiant panel systems. 670 series 01126/05 GB. Function

CALEFFI. Manifolds in composite specifically designed for radiant panel systems. 670 series 01126/05 GB. Function Manifolds in composite specifically designed for radiant panel systems 670 series cert. n 000 ISO 900 CALEFFI 06/05 GB Function Manifolds in composite are used to control and distribute the fluid in the

More information

Electronic Circuit Breaker ESS20-0..

Electronic Circuit Breaker ESS20-0.. Electronic Circuit Breaker ES-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode

More information

SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS)

SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS) SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS) About company The «Elektroapparat» plant starts its operation in 1922 as a plant manufacturing high-voltage electrical equipment. During the first two

More information

SG-B1 SERIES / SG-A1 SERIES

SG-B1 SERIES / SG-A1 SERIES 643 Door with Solenoid Interlock / Door Ultra-slim SG-B1 SERIES / SG-A1 SERIES Related Information General terms and conditions... F-7 General precautions... P.1501 PHOTO PHOTO Conforming to Machine &

More information

DX³ 4-pole RCBO 6000 A/10 ka

DX³ 4-pole RCBO 6000 A/10 ka 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ 4-pole RCBO CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

Phase + Neutral, neutral on right side

Phase + Neutral, neutral on right side 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX 3 MCB 6000 A / 10 ka Cat.. N (s): 4 074 67 / 68 / 69 / 70 / 71 / 72 / 73 / 74 / 75 / 76 / 77 / 78 / 79 ; 4 077 33 / 34

More information

CALEFFI. Composite manifolds specifically designed for radiant panel systems. 670 series 01126/18 GB. replaces dp 01126/11 GB.

CALEFFI. Composite manifolds specifically designed for radiant panel systems. 670 series 01126/18 GB. replaces dp 01126/11 GB. Composite manifolds specifically designed for radiant panel systems 670 series FM 165 00 CALEFFI 0116/18 GB replaces dp 0116/11 GB Function Composite manifolds are used to control and distribute the medium

More information

Series PD directly operated solenoid valves

Series PD directly operated solenoid valves > Series PD solenoid valves CATALOGUE > Release 8.8 Series PD directly operated solenoid valves /-way - Normally Closed (NC) Please note that all Series PD solenoid valves are supplied with direct current

More information

DYNACOMP. The top-class reactive power compensator

DYNACOMP. The top-class reactive power compensator DYNACOMP The top-class reactive power compensator Dynacomp vs Electromechanical switching of capacitors Electromechanical switching of capacitors The Dynacomp : the top-class dynamic compensator Transients

More information

ADVANCE System ADVANCE SYSTEM IP66 MODULAR SYSTEM FOR COMBINATION UNITS VERSIONS MODULE 136 MODULE 106. t. 56. Without protective devices

ADVANCE System ADVANCE SYSTEM IP66 MODULAR SYSTEM FOR COMBINATION UNITS VERSIONS MODULE 136 MODULE 106. t. 56. Without protective devices ADVANCE System ADVANCE SYSTEM IP66 MODULAR SYSTEM FOR COMBINATION UNITS Without protective devices Interlocked-switch socket outlets QUADRA Series socket outlets For 16 and 32 A currents Protection degree

More information

Metal Clad Air Insulated Switchgear

Metal Clad Air Insulated Switchgear Metal Clad Air Insulated Switchgear 1/ SecoGear Metal Clad Switchgear Features Fully metal-clad Equipped with Embedded pole VCB Full Front access (can be installed against wall) Perfect interlocking system

More information

DX³ RCCBs - ID 4P up to 100 A

DX³ RCCBs - ID 4P up to 100 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ s - ID CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

CAST RESIN TRANSFORMERS

CAST RESIN TRANSFORMERS MODEL TAM CAST RESIN - TAM TYPE Epoxy cast resin dry-type transformers are recommended to operate in places that require security, the materials used in its construction are hard to combust and are self-extinguishable

More information

MITRAS MATERIALS GMBH

MITRAS MATERIALS GMBH MITRAS MATERIALS GMBH Friedrich-Ochs-Str. 2 92637 Weiden/Opf. Tel.: 0961 / 89-810 / 89-812 Fax: 0961 / 89-672 Directory of services L a b o r a t o r y MITRAS MATERIALS GMBH Edition 02/18 Rev. 08 page

More information

Single-phase CT current transformers Cat. Nos :

Single-phase CT current transformers Cat. Nos : Index Pages 1. Description - Use... 2 2. Range...2 3. Overall dimensions...2 4. Preparation - Connection... 3 5. General characteristics...5 6. Compliance and approvals...7 1/6 1. DESCRIPTION - USE Closed-type

More information

Components: Dimensions / Order Codes Clamp Body. * 1st part of STAUFF Group 4. * Exact outside diameters Ø D1 / Ø D2 (mm) Clamp Body.

Components: Dimensions / Order Codes Clamp Body. * 1st part of STAUFF Group 4. * Exact outside diameters Ø D1 / Ø D2 (mm) Clamp Body. Components: Dimensions / Order Codes Clamp Body Clamp Body Colour: Green Material code: PP 4 PP One clamp body is consisting of two clamp halves. 1st part of STAUFF 4 Exact outside diameters Ø D1 / Ø D2

More information

EQUIPMENT FOR CONNECTION OF A PHOTOVOLTAIC INSTALLATION (UP TO 5 KW)

EQUIPMENT FOR CONNECTION OF A PHOTOVOLTAIC INSTALLATION (UP TO 5 KW) Catalogue photovoltaic installations 2005 EQUIPMENT FOR CONNECTION OF A PHOTOVOLTAIC INSTALLATION (UP TO 5 KW) "POSSIBILITY OF ASSEMBLY FOR BIDIRECTIONAL ELECTRONIC MONOPHASE METER FOR ALL VERSIONS". MODULAR

More information

PE-HDXc pipes (physically cross-linked polyethylene pipes)

PE-HDXc pipes (physically cross-linked polyethylene pipes) pipes (physically cross-linked polyethylene pipes) Applications: Domestic drinking water installations, radiator connections and surface regulation Special properties high chemical resistance (according

More information

13.1. Range of Enclosures. KRONECTION Box A 2 for up to 2 pairs. Expert Knowledge. Short survey of the KRONECTION Box A 2 for up to 2 pairs

13.1. Range of Enclosures. KRONECTION Box A 2 for up to 2 pairs. Expert Knowledge. Short survey of the KRONECTION Box A 2 for up to 2 pairs KRONECTION Box A 2 for up to 2 pairs Short survey of the KRONECTION Box A 2 for up to 2 pairs The KRONECTION Box A 2, which is equipped with connection contacts on the right and left, serves as a line

More information

4 Remote I/O. Enclosures for Fieldstations Series 8126 (Customer-Specific)

4 Remote I/O. Enclosures for Fieldstations Series 8126 (Customer-Specific) 4 Remote I/O Series 86 078E00 Series 86 enclosures of glass-fibre reinforced polyester resin or of high grade steel are used in larger control stations and control station combinations. Special sizes are

More information

Crastin PBT Thermoplastic polyester resins

Crastin PBT Thermoplastic polyester resins Crastin PBT Thermoplastic polyester resins Product guide and properties Start with DuPont Engineering Polymers DuPont s registered trademark Crastin PBT Thermoplastic polyester resins Introduction CRASTIN

More information

produces and delivers products worldwide can provide the optimal solution for your requirements. are dedicated to supplying you with

produces and delivers products worldwide can provide the optimal solution for your requirements. are dedicated to supplying you with www.ppcinsulators.com The very Best. The very Best. That s what we deliver. Only a company that develops, produces and delivers products worldwide can provide the optimal solution for your requirements.

More information

RiLine mm system technology for the global market

RiLine mm system technology for the global market 60 system technology for the global market 02 RiLine60 Busbar systems 3 and 4 pole Support + bars + contact hazard protection Flat copper bar system, see 276 in HB 33 PLS busbar system, see 278 in HB 33

More information

Phase + Neutral, neutral on left side

Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

The Modular System. Modular System

The Modular System. Modular System Modular System The Modular System The CUBIC modular system is based on a concept of standard modules for the construction of electrical panels. Using a relatively few standard parts it is possible to construct

More information

Product Overview. Transformers & Reactors. Proficient. Innovative. Customer-orientated. Transformers up to 8MVA AC/DC Reactors up to 3000A

Product Overview. Transformers & Reactors. Proficient. Innovative. Customer-orientated. Transformers up to 8MVA AC/DC Reactors up to 3000A Proficient. Innovative. Customer-orientated Transformers up to 8MVA AC/DC Reactors up to 3000A Power Transformers Cast Resin Transformers High-Current Transformers AC/DC Reactors Variable Transformers

More information

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

RX 3 MCB 4500 A Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 RX 3 MCB 4500 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

High Power Switches. Expertly engineered for reliable performance. L High Power Switches

High Power Switches. Expertly engineered for reliable performance. L High Power Switches High Power Switches Expertly engineered for reliable performance Your problem: High power switches are critical to your operation. Not only do they help protect your people from injury, they help protect

More information

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG Medium-Voltage Equipment Selection and Ordering Data Catalog HG 11.02 2011 Answers for energy. R-HG11-172.tif 2 Siemens HG 11.02 2011 Contents SION Vacuum Circuit-Breakers Medium-Voltage Equipment Catalog

More information

LV Bushing Oil to Air Dry Insulation PTAB-SLV832

LV Bushing Oil to Air Dry Insulation PTAB-SLV832 LV Bushing Oil to Air Dry Insulation PTAB-SLV832 Technical Guide 600 V, 30 kv BIL, 600-2500 A 5/8" Integral Flange Bushing 1.0" Integral Flange Bushing 1.25" Bushing General Description The ABB low voltage

More information

Indexing Plunger 417. Triangular Knobs, Made from Plastic. Triangular Knobs, Made from Stainless Steel

Indexing Plunger 417. Triangular Knobs, Made from Plastic. Triangular Knobs, Made from Stainless Steel Standard Parts for Operating - Overview Cam-Action Indexing Plungers / Indexing Plungers Cam-Action Indexing Plunger 612, Made from Steel and Stainless Steel Page 532 Page 533 Indexing Plunger 417 Indexing

More information

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions to 00 A Accessories Enclosed Characteristics M e atysm_007_a cat M s atysm_0_a cat products are and 4pole switches remotely controlled by volt free contacts ( ) or automatic transfer switches ( ). They

More information

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V echnical data sheet SH24A-SR.. Modulating linear actuators for adjusting air dampers and slide valves in ventilation and air conditioning systems in buildings For air dampers up to approx. 3 m 2 Actuating

More information

Profile series I-40. System kit Profile series I-40

Profile series I-40. System kit Profile series I-40 Profile series I-40 System kit Profile series I-40 n n n a n n n R n a R 45 Profile series I-40 Contents 1 Technical data/profile machining F f Page 1 2 Page 1 3 Page 1 5 Page 1 8 Profiles Page 2 2 3000

More information

(1,5 modules per pole)

(1,5 modules per pole) 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 36kA, 80A CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Motor Circuit Breakers C3

Motor Circuit Breakers C3 Motor Circuit Breakers C3 Motor protection rating up to 100 Amps Short circuit breaking capacity up to 100kA Phase failure protection DIN rail mounting Wide range of accessories Options and ordering codes

More information

Safety rope switches with reset for emergency stop

Safety rope switches with reset for emergency stop Safety rope switches with reset for emergency stop Selection diagram 8 8 83 ACTUATORS ACTUATORS CONTACT BLOCKS 18 9 21 1NO+ FP FD FL FC 22 33 34 LED signalling light CONDUIT ENTRIES For other available

More information

RoHS 2011/65/EU ISO 9001 ISO BS OHSAS 18001:2007 GREEN ELECTRONICS CTF. Connectors

RoHS 2011/65/EU ISO 9001 ISO BS OHSAS 18001:2007 GREEN ELECTRONICS CTF. Connectors RoHS 2011/65/EU e3 GREEN ELECTRONICS ISO 9001 ISO 14001 BS OHSAS 18001:2007 Connectors Functional characteristics Dimensional class: low RoHS 2011/65/EU Standard colour: green Dimensions: 11.1 x 15.5 mm

More information

C A B L E C O N N E C T O R S

C A B L E C O N N E C T O R S Quality in connection! Elematic Cabling Systems offers a large and complete range of crimping terminals, lugs and terminal blocks to satisfy the most different connection requirements in the widest application

More information

EPOXY RESIN MEDIUM VOLTAGE INSULATORS

EPOXY RESIN MEDIUM VOLTAGE INSULATORS Indoor epoxy resin Raw material Aromatic epoxy resin, hardened with dicarboxylic acid anhydrides filled with silanised silica Tensile strength 79,28 /mm² ISO R 527 Flexural strength 102,45 /mm² ISO R 178

More information

TECHNICAL DIVISION GALILEO 2 EB Rev. MAY-16

TECHNICAL DIVISION GALILEO 2 EB Rev. MAY-16 Applications Optic Insulation class Protection degree LED Modules Tilt Angle Dimensions Weight Exposed surface Mounting Gear tray Operating temp. Storage temp. Main reference standards MAIN CHARACTERISTICS

More information

045 : 2000 CEB STANDARD

045 : 2000 CEB STANDARD 045 : 2000 CEB STANDARD LOW VOLTAGE FUSE SWITCH DISCONNECTOR CEYLON ELECTRICITY BOARD SRI LANKA Specification for LOW VOLTAGE FUSE SWITCH DISCONNECTOR CEB Standard 045 : 2000 CEYLON ELECTRICITY BOARD No.

More information

CENTRIFUGAL FAN COIL UNIT VCE

CENTRIFUGAL FAN COIL UNIT VCE CENTRIFUGAL FAN COIL UNIT VCE 0,51 kw 11,00 kw 0,85 kw 23,75 kw 129 m 3 /h 2003 m 3 /h VCE DESIGN QUALITY COMFORTRELIABILITY 3VERSION12 SIZE DESIGN VCEx0 vertical with cabinet Air intake: bottom vertical

More information

Prisma Plus G enclosures IP30, IP31, IP43 enclosures

Prisma Plus G enclosures IP30, IP31, IP43 enclosures Prisma Plus G IP30, IP31, IP43 Prisma Plus G IP30, IP31, IP43 Presentation For safe and upgradeable electrical switchboards > Safety of people and property > Continuity of service > Optimization and upgradeability

More information

15 kv and 25 kv Thru-Bushings

15 kv and 25 kv Thru-Bushings Page 1 2001 ELRIM Cycloaliphatic Epoxy Provides: Nontracking, self-scouring, nonweathering performance Superior dielectric strength, dielectric loss and power factor Choice of shapes allows design innovation

More information

TKD SERIES 3-WAY BALL VALVES - TRUE UNION

TKD SERIES 3-WAY BALL VALVES - TRUE UNION TKD SERIES 3-WAY BALL VALVES - TRUE UNION The TKD offers a host of advanced features that set it apart from other multi-port valves. The patented seat stop carrier allows for in-line micro-adjustment of

More information

023 : 2006 CEB STANDARD. 12kV & 36kV LOAD BREAK SWITCHES CEYLON ELECTRICITY BOARD SRI LANKA

023 : 2006 CEB STANDARD. 12kV & 36kV LOAD BREAK SWITCHES CEYLON ELECTRICITY BOARD SRI LANKA 023 : 2006 CEB STANDARD 12kV & 36kV LOAD BREAK SWITCHES CEYLON ELECTRICITY BOARD SRI LANKA Specification for 12kV & 36kV LOAD BREAK SWITCHES CEB Standard 023 : 2006 CEYLON ELECTRICITY BOARD No. 50, Sir

More information

CONDUFIX Cable protection system. Protective conduits Connection fittings Connection manifold 90 -flange System holder Cable assemblies

CONDUFIX Cable protection system. Protective conduits Connection fittings Connection manifold 90 -flange System holder Cable assemblies 1 CONUFIX Cable protection system Protective conduits Connection fittings Connection manifold 90 -flange System holder Cable assemblies Reaching new heights in automation Contents: - CONUFIX - Advantages

More information

Ω FLEX - Insulated copper flexible bars

Ω FLEX - Insulated copper flexible bars - Insulated copper flexible bars bars are made of red copper laminates (Cu ETP) coated with an extruded PVC insulation which gives excellent electrical insulation even in the presence of dampness, aggressive

More information

TECHNICAL DIVISION GALILEO 1 EB Rev. OCT-15

TECHNICAL DIVISION GALILEO 1 EB Rev. OCT-15 Applications Optic Insulation class Protection degree LED Modules Tilt Angle Dimensions Weight Exposed surface Mounting Gear tray Operating temp. Storage temp. Main reference standards MAIN CHARACTERISTICS

More information

CALEFFI. Pre-assembled distribution manifold for radiant panel systems S1 series 01144/11 GB. Replaces 01144/07 GB.

CALEFFI. Pre-assembled distribution manifold for radiant panel systems S1 series 01144/11 GB. Replaces 01144/07 GB. Pre-assembled distribution manifold for radiant panel systems 668...S series ACCREDITED ISO 900 FM 65 ISO 900 No. 000 0/ GB Replaces 0/07 GB Function The distribution manifold for radiant panel systems

More information

EMPAC Metal enclosed capacitor bank for wind applications

EMPAC Metal enclosed capacitor bank for wind applications EMPAC Metal enclosed capacitor bank for wind applications Introduction The EMPAC is a Metal Enclosed Capacitor Bank suitable for voltages between 1 kv and 36 kv for reactive compensation in MV networks

More information

contents MALLEABLE PIPE FITTINGS BUsHEs NiPPlEs PlUgs caps BENds BackNUTs UNioNs TEEs 171 cross PN25 p socket PN25 p socket PN25 p.

contents MALLEABLE PIPE FITTINGS BUsHEs NiPPlEs PlUgs caps BENds BackNUTs UNioNs TEEs 171 cross PN25 p socket PN25 p socket PN25 p. contents BUsHEs 140 Hexagon Bush p.5 NiPPlEs 144 octagon Nipple p.6 145 Hexagon Nipple p.6 PlUgs 146 Beaded Plug - solid p.7 147 Plain Plug - Hollow p.7 148 Plain Plug - solid p.7 149 countersunk Plug

More information

VIDEO MOTORE TENSIONED

VIDEO MOTORE TENSIONED Helgi Europe education@helgi-solutions.com business@helgi-solutions.com www.helgi-solutions.com Matt white canvas with black border version VIDEO MOTORE TENSIONED Electric projection screen with alluminum

More information

Outdoor disconnectors FTr (previously 6400 and 6410) single- and three-pole design rated voltage 25 and 38.5 kv rated current 400 and 630 A

Outdoor disconnectors FTr (previously 6400 and 6410) single- and three-pole design rated voltage 25 and 38.5 kv rated current 400 and 630 A Outdoor disconnectors FTr (previously 6 and 6410) single- and three-pole design rated voltage 25 and 38.5 kv rated current and 6 A 1 Outdoor disconnectors Outdoor disconnectors, produced in accordance

More information

Energy Supply Systems

Energy Supply Systems Energy Supply Systems SINGLE POLE INSULATED CONDUCTOR RAIL 815 100 amps KAT0815-0001b-E Conductor rail system in a high bay storage Slip ring with conductor rail system in a stretch-foil packing machine

More information

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) 1800 24kV to 550kV up to 5000A IEC 60137-2008 Features If you need any transformer bushing proven in operation conditions around the world, Trench

More information

Series PD directly operated solenoid valves

Series PD directly operated solenoid valves > Series PD solenoid valves CATALOGUE > Release 8.7 Series PD directly operated solenoid valves New /-way Normally Closed (NC) Note: all Series PD /-way solenoid valves are basically in DC. To operate

More information

Magnetic Overcurrent Circuit Breaker

Magnetic Overcurrent Circuit Breaker Magnetic Overcurrent Circuit Breaker 808-... Description ngle pole miniaturised magnetic circuit breakers with unique highspeed operating mechanism and push/pull on/off manual actuation. Fitted with electrically

More information

B kv T&D GAS INSULATED SWITCHGEAR

B kv T&D GAS INSULATED SWITCHGEAR GAS INSULATED SWITCHGEAR B 105 170 300 kv The increasing demand for electrical power in cities and industrial centers necessitates the installation of a compact and efficient distribution and transmission

More information

SUMMARY SPIDERS. Pages 3.03 >> 3.25 SPIDERS :: Suggested mounting instructions Page 3.21

SUMMARY SPIDERS. Pages 3.03 >> 3.25 SPIDERS :: Suggested mounting instructions Page 3.21 :: SUMMARY :: Pages 3.03 >> 3.2 Casted stainless steel spider Ref: S3000 > Page 3.0 Ref: S3001 > Page 3.07 Ref: S3006 > Page 3.09 Casted aluminium spider Ref: S3007 > Page 3.11 Laser cut spider Ref: S3003

More information

Dimensions / Order Codes

Dimensions / Order Codes U-Bolt Clamps Dimensions / Flat Steel U-Bolt with Plastic Pipe Saddle (Short) and U-Profile Type FB+RUK (To be used as Fixed Point Clamps only) B1 ø D1 H4 H2 H3 H1 L2 L1 B2 Flat Steel U-Bolt (type FB)

More information

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request 125 to 4000 A sirco_353_a_1_cat sirco_296_a_1_cat sirco_300_b switches are manually operated or motorised multipolar load break switches. They break on and off under load and provide safety isolation for

More information

Safety rope switch without reset for simple stop

Safety rope switch without reset for simple stop afety rope switch without reset for simple stop election diagram FP 4-M2 FD 4-M2 FL 4-M2 FR 4-M2 FM 4-M2 FX 4-M2 FZ 4-M2 ACTUATOR 9 ACTUATOR 9 0 CONTACT BLOCK 1 9 21 1NO+ FP FD FL FC 33 34 CONDUIT ENTRIE

More information

Junction boxes for control, monitoring and control panel Ex tb

Junction boxes for control, monitoring and control panel Ex tb Junction boxes for control, monitoring and control panel - Zone 21, 22 - Category 2D - Aluminium, reinforced polyester or stainless steel enclosures - Standard or custom products Inspection window Padlockable

More information

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency

Electrical data Nominal voltage AC V / DC V Nominal voltage frequency Technical data sheet NFG-S2-L Spring-return actuator with emergency control function for adjusting dampers in technical building installations Air damper size up to approx. 2 m² Nominal torque 10 Nm Nominal

More information

35-kV Thru-Bushings F Series (bolt-in) for Air-Insulated to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

35-kV Thru-Bushings F Series (bolt-in) for Air-Insulated to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp Page 1 2018 Equipment Connection Bus Bar, or Grounded Metal Equipment Plate F Series Mounting Holes ELRIM Cycloaliphatic Epoxy Provides: Nontracking, self-scouring, nonweathering performance Superior dielectric

More information

vertical fuse switch disconnectors

vertical fuse switch disconnectors SWITCHGEAR ARS vertical fuse switch disconnectors - touch protection IP 30 from the front - fibre glass extra strenghtened, self extinguishing thermoplastics - double clearance between open contacts -

More information

Rodless cylinders. Series General. Construction characteristics. Technical characteristics. Use and maintenance

Rodless cylinders. Series General. Construction characteristics. Technical characteristics. Use and maintenance Series 1600 Rodless cylinders General The purpose of producing a rodless cylinder is to provide a space saving option over conventional cylinders. On a traditional rod type cylinder, the total space occupied

More information

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy Our brand A strong brand for strong products: The ENERGOLINE brand represents our product portfolio of INDUSTRIAL SWITCHGEAR SYSTEMS. Our products are characterized by a high degree of safety, flexibility

More information

PROBABLY THE BEST FLEXIBLE BAR IN THE WORLD

PROBABLY THE BEST FLEXIBLE BAR IN THE WORLD PROBABLY THE BEST FLEXIBLE BAR IN THE WORLD 2COFLEX COFLEX, THE 4.0 FLEXIBLE BAR From a Teknomega new and advanced manufacturing plant, COFLEX, the only bi-color flexible bar (patented), distinguishes

More information

LOW VOLTAGE CAPACITORS AND CAPACITOR BANKS. Capacitors department

LOW VOLTAGE CAPACITORS AND CAPACITOR BANKS. Capacitors department LOW VOLTAGE CAPACITORS AND CAPACITOR BANKS Capacitors department I Selecting the reactive energy compensation system 3 II Selecting the capacitor type 4 III ALPIVAR 6 IV V VI VII VIII SPECIAL RANGES 25

More information

Liquid filled Thermometers

Liquid filled Thermometers Liquid filled Thermometers Description and general specifications Liquid filled contact thermometers Operating instructions and maintenance Finished product quality control tests 02 02 05 06 1 Description

More information

Dinosaur Flexible Wiring Duct

Dinosaur Flexible Wiring Duct Dinosaur Flexible Wiring Duct Dinosaur self-adhesive flexible duct is ideal for transporting wiring to cabinet doors from control panel interiors (for that part of the cable run that leans against the

More information

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment) TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment) 1 SCOPE OF SUPPLY This specification covers design, manufacture, shop

More information

Single foot switches - PX and PA series

Single foot switches - PX and PA series Single foot switches - PX and PA series Description The PX and PA foot switches are traditional products of Pizzato Elettrica that have recorded a continuous growth and success in the market. Modified

More information

DL /118 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO p max 280 bar Q max 50 l/min

DL /118 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO p max 280 bar Q max 50 l/min 41 211/118 ED DL3 SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO 4401-03 p max 280 bar Q max 50 l/min MOUNTING SURFACE OPERATING PRINCIPLE ISO 4401-03-02-0-05 (CETOP

More information

FL7M-A Series. Aluminum-chip Immunity DC 2-wire Type Cylindrical Proximity Sensors. Specifications. click FEATURES ORDER GUIDE

FL7M-A Series. Aluminum-chip Immunity DC 2-wire Type Cylindrical Proximity Sensors. Specifications. click FEATURES ORDER GUIDE 6 FL7M-A Series FEATURES Workpieces Reliably Sensed Even if Aluminum or Cast Iron Chips Accumulate on the Sensing Head. This DC 2-wire type proximity sensor can be directly connected to programmable controllers

More information

Air Circuit Breakers

Air Circuit Breakers Siemens AG 203 /2 Introduction 3WL air circuit breakers/ non-automatic air circuit breakers up to 6300 A (AC), IEC /8 Introduction /9 3-pole, fixed-mounted versions /6 3-pole, withdrawable versions /23

More information

Proportional pressure reducing valve, pilot operated

Proportional pressure reducing valve, pilot operated Proportional pressure reducing valve, pilot operated Type DRE and DREE Sizes 10 and 25 1) Component series 6X Maximum operating pressure Maximum flow Table of contents Content 315 bar 300 l/min Page Features

More information

Energy Division. PCA Single Column Polymeric Surge Arrester

Energy Division. PCA Single Column Polymeric Surge Arrester Energy Division PCA Single Column Polymeric Surge Arrester Bowthorpe EMP pioneered the development of the polymeric composite housed surge arrester in the early 1980 s and since 1986 has a proven service

More information

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter Preliminary Datasheet Technical Datasheet Compact DC Energy Meter RISH EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor and control

More information

CALEFFI. Pre-assembled distribution manifolds for. heating and air-conditioning systems. 663 series 01065/18 GB. replaces dp 01065/06 GB.

CALEFFI. Pre-assembled distribution manifolds for. heating and air-conditioning systems. 663 series 01065/18 GB. replaces dp 01065/06 GB. Pre-assembled distribution manifolds for heating and air-conditioning systems 663 series FM 21654 003 065/18 GB replaces dp 065/06 GB Function The pre-assembled distribution manifolds are designed to optimise

More information

Overview of types. Technical data. Safety notes

Overview of types. Technical data. Safety notes echnical data sheet LH4A-S-P.. Linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air dampers up to approx.

More information

CONTROL CONSOLES FAMOR S.A. UL. KASZUBSKA BYDGOSZCZ POLAND

CONTROL CONSOLES FAMOR S.A. UL. KASZUBSKA BYDGOSZCZ POLAND CONTROL CONSOLES FAMOR S.A. UL. KASZUBSKA 25 85-048 BYDGOSZCZ POLAND tel. +48-52/366-82-02 fax +48-52/366-82-03 e-mail:marketing@famor.pl http://www.famor.pl CONTROL CONSOLES DESIGNATION In our consoles

More information

Austin Insulators Inc. Manufacturers of Austin Base & Guy Insulators and Isolation Transformers for Radio Antenna Towers.

Austin Insulators Inc. Manufacturers of Austin Base & Guy Insulators and Isolation Transformers for Radio Antenna Towers. Austin Insulators Inc. Manufacturers of Austin Base & Guy Insulators and Isolation Transformers for Radio Antenna Towers Product Catalogue e&oe 05.11.01.a Austin Insulators Inc. Austin Ring Type Isolation

More information

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor Technical data sheet GK24G- SuperCap rotary actuator with emergency setting function and extended functionalities in the IP66 protective housing for adjusting air dampers in ventilation and air-conditioning

More information

YOUR KEY ENERGY EFFICIENCY PARTNER CAST RESIN DRY-TYPE TRANSFORMERS

YOUR KEY ENERGY EFFICIENCY PARTNER CAST RESIN DRY-TYPE TRANSFORMERS YOUR KEY ENERGY EFFICIENCY PARTNER CAST RESIN DRY-TYPE TRANSFORMERS 1 TABLE OF CONTENTS ABOUT SVEL GROUP CAST-RESIN TRANSFORMERS ACCESSORIES AND OPTIONAL EQUIPMENT ENCLOSURE AND HOUSING TESTS AND QUALITY

More information

Snap-in covers I Voltage taps

Snap-in covers I Voltage taps ACCESSORIES Accessories for analogue instruments, current transformers, switchboards, voltage taps for busbars and round conductors. Snap-in covers I Voltage taps Voltage taps page 10/1 10 For analogue

More information

Safety switches with separate actuator

Safety switches with separate actuator Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD5 VF KEYD6 VF KEYD7 VF KEYD8 VF KEYD10 VF KEYD11 ACTUATORS CONTACT BLOCKS FR FX FK FW 5 6 7 11 1 14 NC NC

More information