Our Company. NyFlex INTERNATIONAL OUR MANUFACTURING RANGE OUR FORTH-COMING PRODUCTS U JIS-C2004 L JIS-C2005 JIS-C2006 E TRADERS
|
|
- Dayna Francis
- 5 years ago
- Views:
Transcription
1 Our Company Nylex Group established in 1 and leading through excellence and innovation, the buzz word at Nylex We at Nylex are group of trained personnel with each one being updated in their respective fields, TRADERS INTERNATIONAL is innovation and quality, and yes, excelling through it and that it is precisely why, Nylex is way ahead of others in this segment. Nylex products are manufactured from quality raw material to the required specification of users and can be relied upon to deliver long term durable solutions to customers satisfaction. Nylex, under one roof supplies various items in Machinery, ardware, Electrical wiring accessories, Switchboard control panel accessories, Porcelain items, Conduit fittings, Wire, Cables, etc. (i.e. from a Screw to each and every part which is used in electrical industry). We have the privelege to export above motivated personnel in production, quality and marketing. Our motto to "Serve clients exactly to their needs and whilst ensuring timely deliveries." We have the latest facilities for production, testing and have been certified an ISO 002 Company for establishing quality systems norms. We are able to offer a wide range of products which are typetested or certified by international authorities. We believe in priceless quality at affordable prices and hence our growth allows us opportunities to serve our clients worldover. In view of above we may request you to please send us your requirement whatever it may be along with your NyFlex OUR MANUFACTURING RANGE Panel Board Accessories, Cam Locks, Non Metallic Locks, Door Knobs, inges, andles, Insulated andles, Inspection Window, Mounting Rails, Filters, Buzzer, Switches, Cam Switches, Pilot Lamps, Push Buttons, Control Units, our Meter, Tin Copper Cables Terminals, Aluminum, Copper Bi-Metallic Cable Lugs, Analogue Meter, Ammeter/Voltmeter, Frequency Meter, Maximum Demand meter etc. Residual Current Device, Miniature Circuit Breakers, Isolating Switches, Relay and Relay Sockets, Electrical Wiring Accessories, Industrial Plugs and Sockets, Modular Fuse Carriers and Cartridges Fuses, Knife Fuse and Fuse Base, Fuse Puller / Carrier, Connection Blocks, Brass Terminals and Insulated Bus Bar, Line Tapes, Bimetal Branching Terminal, B. I. Connectors, Test Terminal Blocks, Terminal Blocks, Terminals and Connectors, C. T. Current / Voltage Transformer, Control / Current Transformer, PG Cable Glands, Bus Bar Support, Comb Bars, DDLO Fuse Link, Operating Rod, Earthing Accessories. Galvanized Steel Flexible PVC Coated Conduit, Liquid Tight Flexible PVC Coated Galvanized Conduit, ot Dipped Galvanized steel Flexible Conduit, DPE/PVC Flexible Conduit Galvanized Conduit Accessories. products worldwide strictly meeting customer quality and specification, drawing, etc. and we will send you our best Luminaries and Accessories. delivery requirement. and prompt reply. Our annual growth is almost 0% over the previous year, which alone speaks - of our performance. OUR FORT-COMING PRODUCTS U JIS-C2004 L JIS-C200 JIS-C200 E-004 E 81A E E 12101B LR LR 84 Under Voltage Relay (Single Phase) Over Voltage Relay (Single Phase) Under Voltage Relay (Three Phase) Over Voltage Relay (Three Phase) Phase Reversal/Phase Loss Phase unbalance Relay (Three Phase) Motor Protection Relay Without display (Current Sensing Based Technology) Motor Protection Relay with Voltage, Amps & Frequency Display (Current Sensing) Single Phase Ammeter Micro Controller Based Technology with CT Ratio Site Programmable Alarm Annunciate with Data Logging Automatic Power Factor Correction(, 8, 12 Stages)
2 Stand Off Insulators Conical Type Insulators eight Insert KAM Rt Rb i Nominal Voltage mm Code No Dia mm Dia mm mm (AC/DC) 2 M KMB-C2 (M) /00 M KMB-C (M) /0 M8 KMB-C8 (M8) /0 M8 KMB-C8 (M8) /1200 i Rt Rb M10 KMB-C10 (M10) / M10 KMB-C (M10) / 0 M12 KMB-C120 (M12) / 0 M10 KMB-C (M10) /10 0 M12 KMB-C120 (M12) /10 0 M10 KMB-C (M10) /20 0 M12 KMB-C120 (M12) /20 exagonal Type Insulators eight Insert KAM A/F R i Nominal Voltage mm Code No mm Dia mm mm (AC/DC) i R A/F A/F 20 M4 KMB-420 (M4) /0 20 M KMB-20 (M) /0 2 M KMB-2 (M) /00 2 M KMB-M2 (M) /00 M KMB- (M) /0 M8 KMB-8 (M8) /0 3 M KMB-3 (M) /0 3 M8 KMB-83 (M8) /0 3 M10 KMB-103 (M10) /0 M8 KMB-8 (M8) 1 0/1200 M10 KMB-10 (M10) 1 0/ M8 KMB-84 (M8) / M10 KMB-104 (M10) / M10 KMB- (M10) / 0 M12 KMB-120 (M12) / 0 M10 KMB- (M10) /10 0 M12 KMB-120 (M12) /10 M10 KMB-10 (M10) 41 2 /10 M12 KMB-12 (M12) /10 0 M10 KMB- (M10) /20 0 M12 KMB-120 (M12) /20 M10 KMB-10 (M10) /20 M12 KMB-12 (M12) /20 M10 KMB-10E (M10) /20 All Dimensions are in MM Insert : Brass / Steel (Zinc Passivated) Material : DMC (Dough Moulding Compound) (UL 4 V-0) 1
3 Drum Type Insulators eight Insert KAM A/F R i Nominal Voltage mm Code No mm Dia mm mm (AC/DC) 20 M4 KMB-D420 (M4) /0 20 M KMB-D20 (M) /0 2 M KMB-D2 (M) /00 M KMB-D (M) /0 M8 KMB-D8 (M) /0 3 M KMB-D3 (M) /0 3 M8 KMB-D83 (M8) /0 3 M10 KMB-D103 (M10) /0 M8 KMB-D8 (M8) /1200 M10 KMB-D10 (M10) / M8 KMB-D84 (M8) / M10 KMB-D 104 (M10) /1200 R 0 M10 KMB-D (M10) / i A/F 0 M12 KMB-D120 (M12) / 1 M8 KMB-D81E (M8) / M10 KMB-D (M10) /10 0 M12 KMB-D120 (M12) /10 M10 KMB-D10 (M10) 41 2 /10 M12 KMB-D12 (M12) /10 0 M10 KMB-D (M10) /20 0 M12 KMB-D120 (M12) /20 M10 KMB-D10 (M10) /20 M12 KMB-D12 (M12) /20 M10 KMB-D10E (M12) /20 Cylindrical Type Insulators 2 M KMB-CL222 (M) /00 2 M8 KMB-CL222 (M8) /00 M KMB-CL (M) /0 M8 KMB-CL (M8) /0 M10 KMB-CL (M10) /0 M KMB-CL (M) /1200 M8 KMB-CL (M8) /1200 M10 KMB-CL (M10) / M KMB-CL0 (M) / 0 M8 KMB-CL0 (M8) / 0 M10 KMB-CL0 (M10) / R 0 M10 KMB-CL00 (M10) / i 0 M KMB-CL20 (M) /10 0 M8 KMB-CL20 (M8) /10 0 M10 KMB-CL20 (M10) /10 0 M KMB-CL0 (M) - 20 /10 0 M8 KMB-CL0 (M8) - 20 /10 0 M10 KMB-CL0 (M10) - 20 /10 3 M KMB-CL23 (M) /10 3 M8 KMB-CL23 (M8) /10 3 M10 KMB-CL23 (M10) /10 2 All Dimensions are in MM Insert : Brass / Steel (Zinc Passivated) Material : DMC (Dough Moulding Compound) (UL 4 V-0)
4 Full exagonal Type Insulators Insert M4 eight KAM i Nominal Voltage mm Code mm (AC/DC) 1 KMB14F41 /200 ex Face To Face (A/F 14mm) Insert M eight KAM i Nominal Voltage mm Code mm (AC/DC) 1 KMB14F1 / KMB14F420 0/0 2 KMB14F /00 20 KMB14F20 0/0 2 KMB14F2 10 0/00 A/F Insert M ex Face To Face (A/F 20MM) Insert M i i i A/F Bolt (M/M8) A/F A/F 10mm A/F 20 KMB20F20 0/0 20 KMB20F20 0/0 2 KMB20F2 10 0/00 KMB20F 10 00/0 3 KMB20F /0 KMB20F 1 0/ KMB20F4 1 0/ KMB20F / KMB20F / 0 KMB20F0 20 /10 Insert M 2 KMB2F2 10 0/00 KMB2F 10 00/0 3 KMB2F /0 KMB2F 1 0/ KMB2F4 1 0/ KMB2F / KMB2F / 0 KMB2F0 20 /10 Insert M8 KMB3F /0 3 KMB3F /0 KMB3F8 1 0/ KMB3F84 1 0/ KMB3F / KMB3F / 0 KMB3F 20 /10 Insert M10 3 KMB4F /0 KMB4F10 1 0/ KMB4F / KMB4F / KMB4F / 0 KMB4F 20 /10 0 KMB4F 2 /10 KMB4F /20 0 KMB4F /00 KMB4F10 /00 2 KMB20F2 10 0/00 KMB20F 10 00/0 3 KMB20F /0 KMB20F 1 0/ KMB20F4 1 0/ KMB20F / KMB20F / 0 KMB20F0 20 /10 ex Face To Face (A/F 2MM) Insert M8 ex Face To Face (A/F 3mm) ex Face To Face (A/F 4mm) 2 KMB2F /00 KMB2F /0 3 KMB2F /0 KMB2F8 1 0/ KMB2F84 1 0/ KMB2F / KMB2F / 0 KMB2F 20 /10 Insert M10 KMB3F /0 3 KMB3F /0 KMB3F10 1 0/ KMB3F / KMB3F / KMB3F / 0 KMB3F 20 /10 Insert M12 3 KMB4F /0 KMB4F12 1 0/ KMB4F / KMB4F / KMB4F / 0 KMB4F /10 0 KMB4F /10 KMB4F /20 0 KMB4F120 /00 KMB4F12 /00 All Dimensions are in MM Insert : Brass / Steel (Zinc Passivated) Material : DMC (Dough Moulding Compound) (UL 4 V-0) 3
5 Octagonal ex Insulators eight KAM () mm code 20 KMB-O420 (M4) 2 KMB-O42 (M4) KMB-O (M) 3 KMB-O3 (M) KMB-O8 (M8) 4 KMB-O84 (M8) 0 KMB-O (M10) KMB-O10 (M10) 0 KMB-O (M10) 0 KMB-O120 (M12) KMB-O12 (M12) Round Insulators eight KAM () mm code 3 KMB-RO3 (M) KMB-RO8 (M8) 0 KMB-RO (M10) Double ex Insulators eight KAM () mm code 2 KMB-D2 (M) KMB-D (M) 3 KMB-D3 (M) 3 KMB-D83 (M8) KMB-D8 (M8) 0 KMB-D (M10) Barrel Type D2 eight Insert KAM D1 D2 D3 F mm Code No 3 M10 KMB-BT103 (M10) F D3 D1 M8 KMB-D8 (M8) M10 KMB-D104 (M10) M10 KMB-D (M10) M10 KMB-D10 (M10) All Dimensions are in MM Insert : Brass / Steel (Zinc Passivated) Material : DMC (Dough Moulding Compound) (UL 4 V-0)
6 Round ex Insulators Insert M eight KAM i Nominal Voltage mm Code mm (AC/DC) Round & ex Face To Face (A/F 20mm) Insert M eight KAM i Nominal Voltage mm Code mm (AC/DC) 20 KMB20RX20 0/0 2 KMB20RX2 10 0/00 20 KMB20RX20 0/0 2 KMB20RX2 10 0/00 Insert M8 Round & ex Face To Face (A/F mm) Insert M10 KMBRX /0 3 KMBRX /0 KMBRX8 1 0/1200 KMBRX /0 3 KMBRX /0 KMBRX10 1 0/1200 Insert M10 Round & ex Face To Face (A/F mm) Insert M12 A/F KMBRX /0 3 KMBRX /0 KMBRX10 1 0/ KMBRX / KMBRX / KMBRX / 0 KMBRX 20 /10 KMBRX10 2 /10 0 KMBRX /20 KMBRX12 1 0/ KMBRX / KMBRX / KMBRX / 0 KMBRX /10 KMBRX12 20 /10 0 KMBRX /10 i Insert M12 Round & ex Face To Face (A/F 0mm) Insert M1 KMB0RX12 1 0/ KMB0RX / 0 KMB0RX /10 0 KMB0RX /10 KMB0RX12 /10 0 KMB0RX / 0 KMB0RX10 20 /10 0 KMB0RX10 20 /10 KMB0RX1 2000/20 Combi Four Pole Conical Insulators 4C Series F A E D C Insert B KAM Code Dimension Insert A B C D E F 4C M 4C M 4C M8 All Dimensions are in MM Insert : Brass / Steel (Zinc Passivated) Material : DMC (Dough Moulding Compound) (UL 4 V-0)
7 L-Supports Single Insulators 10 eight KAM () mm code 0 KMB-LS0 8 KMB-LS8 KMB-LS 12 KMB-LS12 0 Finger Type Insulators One Way Adjustable Finger Type Supports 0 E A 2 1 C B D 12. Busbar KAM Dimension code A B C D E mm X 1 run KMB-FS 10 S mm X 1 run KMB-FS 0 S mm X 1 run KMB-FS 2 S mm X 1 run KMB-FS 10 W mm X 1 run KMB-FS 0 W mm X 1 run KMB-FS 2 W mm X 1 run KMB-FS 10 K mm X 1 run KMB-FS 0 K mm X 1 run KMB-FS 2 K
8 Two Way Adjustable Finger Type Supports F D Busbar KAM Dimension code A B C D E F 0 E A 1 2 C B 12. mm X 2 runs KMB-FS 20 W mm X 2 runs KMB-FS 210 W mm X 2 runs KMB-FS 212 W mm X 2 runs KMB-FS 20 K mm X 2 runs KMB-FS 210 K mm X 2 runs KMB-FS 212 K Three Way Adjustable Finger Type Supports 0 D 2 A F 1 Busbar KAM Dimension code A B C D E F mm X 3 runs KMB-FS W mm X 3 runs KMB-FS 310 W mm X 3 runs KMB-FS 312 W mm X 3 runs KMB-FS K mm X 3 runs KMB-FS 310 K mm X 3 runs KMB-FS 312 K C B E
9 Four Way Adjustable Finger Type Supports F D A C B E F D 1 Busbar KAM Dimension code A B C D E F mm X 4 runs KMB-FS W mm X 4 runs KMB-FS K A 10 mm X 4 runs KMB-FS 410 K mm X 4 runs KMB-FS 412 K C B mm X runs KMB-FS 0 K ** mm X runs KMB-FS 0 K ** mm X 8 runs KMB-FS K ** E F 1 D Busbar KAM Dimension code A B C D E F mm X 1 run KMB-FS ** 10 mm X 1 run KMB-FS ** A 12 mm X 1 run KMB-FS ** mm X 2 runs KMB-FS mm X 2 runs KMB-FS mm X 2 runs KMB-FS C B mm X 3 runs KMB-FS E Busbar with FRP Base Plate Cat No. KMBBBS 01-3x3 / 2x1 TPN with FRP Base Plate Cat No. KMBBBS 02-3x3 TP with FRP Base Plate 8
10 Tripple Pole Supports Triple Pole Neutral (TPN) Support for Double Busbar Y Z N D Z A Z Y1 F C B Busbar KAM Dimension A B C D N Z Y Y1 mmx1run/ph & mmx1run-n KMBTPN-10/ mmX1run/ph & mmx1run-n KMBTPN-1/ mmX1run/ph & mmx1run-n KMBTPN-4/ mmx1run/ph & mmx1run-n KMBTPN-10/ mmX1run/ph & mmx1run-n KMBTPN-1/ mmX1run/ph & mmx1run-n KMBTPN-4/ mmx1run/ph & mmx1run-n KMBTPN-10/ mmX1run/ph & mmx1run-n KMBTPN-1/ mmX1run/ph & mmx1run-n KMBTPN-4/ mmx1run/ph & mmx1run-n KMBTPN-10/ mmX1un/ph & mmx1run-n KMBTPN-1/ mmX1un/ph & mmx1run-n KMBTPN-4/ Busbar KAM Dimension Code A B C D N Z Y Y1 F mmx2runs/ph & mmx1run-n KMBTPN-20/ mmX2runs/ph & 10mmX1run-N KMBTPN-2/ mmX2runs/ph & 12mmX1run-N KMBTPN-214/ mmx2runs/ph & mmx1run-n VTPN-20/ mmX2runs/ph & 10mmX1run-N KMBTPN-2/ mmX2runs/ph & 12mmX1run-N KMBTPN-214/ mmx2runs/ph & mmx1run-n KMBTPN-20/ mmX2runs/ph & 10mmX1run-N KMBTPN-2/ mmX2runs/ph & 12mmX1run-N KMBTPN-214/
11 orizontal Bar Insulators M SP- SP-3 NT-0 NT-0 Vertical Bar Insulators 4 KMB KMB KMB 38-2 KMB KMB KMB 38-4 KMB 38-4
12 Step Insulators M KMB 4 M KMB 4 M KMB
13 KMB M KMB KMB 420 M 10 2 M KMB 4B KMB 4B M KMB B KMB
14 KMB K-20/2 KMB K-20/ KMB K-20/10 KMB K-/ KMB K-212/313 KMB K-20/4 13
15 KMB K-/3 KMB K-0/ KMB K-14/ KMB K-14/ KMB K-/.2..2 KMB K-0/ 14
16 KMB K-0/ KMB K-8/ KMB K-4/ KMB K-/ Ø 8. ole Ø 8. ole KMB K-/ KMB K-8/4 1
17 Ø Ø KMB K-10/ KMB K-/ Ø KMB K-0/0 KMB K-4/ KMB K-/4 1
18 KMB K-/ 2 KMB K-12/ KMB K-/3 KMB K-312/ KMB K-13/ 12 KMB K-410/412 1
19 KMB K-212/313 KMB K-10/ KMB K-/ KMB K-2/ KMB K-20/3 18
20 M 10 M 8 KMB K-101/00 KMB K-420/ M-8 Bush KMB K-/18 KMB K-28/ KMB K-32/2 1
21 M M10 KMB K-/ KMB K-10/12 20 M M KMB K-13/18 42 KMB K-320/ M10 KMB K-333/1 KMB K-31/20 20
22 igh Tension Post Type Insulators Rating KAM code Dia No. of Brass Bush Ribs Sizes 1 MX10mm Deep M10X18mm Deep 3.3 KV KMB-T M12X18 M10X18 Material - DMC MX10 M12X18mm Deep 3 Rating KAM code Dia No. of Brass Bush Ribs Sizes. KV KMB-T M12X18 Material - DMC M10X18 MX10 1 M10X18mm Deep MX10mm Deep 3 M12X18mm Deep Rating KAM code Dia No. of Brass Bush Ribs Sizes. KV KMB-T.S M12X18 Material - DMC on both sides 1 M12X20mm Deep M12X18mm Deep 4 M1X2mm Deep Rating KAM code Dia No. of Brass Bush Ribs Sizes. KV KMB-T. / None M1X2 Material - DMC M12X2 M12X20mm Deep Rating KAM code Dia No. of Brass Bush Ribs Sizes 1 M10X18mm Deep MX12mm Deep KV KMB-T 1 1 M1X3 M10X18 Material - DMC MX12mm 3 M1X3mm Deep 21
23 Epoxy Resin Cast Insulator Rating KAM code Dia No. of Brass Bush Ribs Sizes 1 MX10mm Deep M10X18mm Deep 3.3 KV KMB-ERC M12X18 M10X18 Creepage - 0 mm (minimum) MX10 3 M12X18mm Deep 1 Rating KAM code Dia No. of Brass Bush Ribs Sizes MX10mm Deep M10X18mm Deep. KV KMB-ERC M12X18 M10X18 Creepage - 1 mm (minimum) MX10 3 M12X18mm Deep 1 M10X20mm Deep MX12 Deep Rating KAM code Dia No. of Brass Bush Ribs Sizes KV KMB-ERC 1 1 M1X3 1 M10X18 Creepage - 1 mm (minimum) MX12mm 3 M1X3mm Deep M1X Deep min Rating KAM code Dia No. of Brass Bush Ribs Sizes KV KMB-ERCS 1 M1X3 Creepage - 18 mm (minimum) M10X18 MX12mm M10x1 Deep min 2 Nos. M20X4 Deep min 22
24 Epoxy Resin Cast Insulator Ø D Ø d Rating KAM code Dia No. of Brass Bush Ribs Sizes 22 KV KMB-ERC M1X Creepage - 2 mm (minimum) M10X2 MX1 (2nos.) 210 M10X2 Deep min MX1 Deep min 2 Nos. 3 M1X Deep min Ø D Ø d Rating KAM code Dia No. of Brass Bush Ribs Sizes 33 KV KMB-ERC M1X Creepage mm (minimum) M10X2 MX1 (2nos.) 0 M10X2 Deep min MX1 Deep min 2 Nos. 3 M1X Deep min M14X2mm Rating KAM code Dia No. of Brass Bush Ribs Sizes 33 KV KMB-ERC33S 0 M24X Creepage - 00 mm (minimum) M14X2 M10X20 (2nos.) 4 M10X20mm D M20X4mm Rating KAM code Dia No. of Brass Bush Ribs Sizes 33 KV KMB-ERC33W 8/ M20X Creepage - 18 mm (minimum) M1X M10X1 (2nos.) M1Xmm M10X20mm 4 23
25 LV & V Bushing M/F Bushing (Lower & Upper Part) KAM code Base Top Bore Bore KAM code Dia Dia inner Dia outer Dia KMB-LV KMB-LV KMB-LV KMB-LV KMB-LV 33S KMB-LV KMB-LV S igh Voltage Transformer Bushing Low Voltage Transformer Bushing 24
26 Epoxy Resin Cast Drive Insulators SF Circuit Breaker Interrupter ousings ousing for SF Contact Assemblies in, 22, 33 KV Circuit Breaker KV 22KV 2
27 Epoxy Resin Cast Support Insulators KV 22 KV 33 KV KV 2
28 Technical Specifications PROPERTIES UNITS TEST METODS (ASTM) PYSICAL VALUES SMC DMC EPOXY Specific Gravity D Glass Contents % N.A Water Absorption (24hrs) % D MECANICAL 2 Tensile Strength Kgf/Cm D Flexural Strength Kgf/Cm D Compressive Strength Kgf/Cm D- 10 Impact Strength Izod J/m D ELECTRICAL Dielectric Strength KV/mm D Tracking Index Volts BS ARC Resistance Secs D FLAMMABILITY UL-4 Self Extinguishing V-O Self Extinguishing TOLERANCE CART DIM (mm) TOLERANCE (+) mm mm TE ABOVE VALUES ARE FOR TE STANDARD FORMULA FOLLOWED BY TE COMPANY BUT WE AVE FACILITIES FOR MANUFACTURING SMC, DMC & EPOXY ACCORDING TO TE CUSTOMER REQUIREMENTS. (SMC = SEET MOULDING COMPOUND) (DMC = DOUG MOULDING COMPOUND) mm mm 20 & above 2 mm ALL DATA GIVEN IN TIS CATALOGUE AS BEEN DETERMINED CAREFULLY AT TE COMPANY'S TEST LAB. WIT TE VARIETY OF PURPOSE FOR WIC TE PRODUCTS ARE USED, AND TE METODS AND APPLICATION TECNIQUES EMPLOYED, OWEVER TE DATA AND INFORMATIONS ARE GIVEN ONLY AS A GUIDE, AND ARE NOT BINDING. NO GUARANTEE OF TEIR AUTENTICITY CAN TEREFORE BE ASSUMED IN ALL SITUATIONS AND TE COMPANY RESERVES TE RIGT TO MODIFY FEATURES WITOUT PRIOR NOTICE IN VIEW OF CONTINUED IMPROVEMENTS. 2
29 NOTES
CATALOGUE
www.vemer.it Vemer offers to the Electrical Industry a wide range of products able to meet all the requirements of the modern installer. The digital programmable thermostats, time switches, measurement
More informationDATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT
44LK-500/E.04/002A/A4 PROJECT NO 44LK-500 CHKD. BY VDV VDV A CLIMATIC CONDITIONS THIS DATA SHEET IS APPLICABLE FOR IN UTILITY BOILER PACKAGE DESIGN AMBIENT TEMPERATURE 45 C 2 ALTITUDE ( ABOVE MSL ) 6.7
More informationS R O T A L SU IN INSULATORS
INSULATORS INSULATORS LV INSULATORS & MV BUSHINGS BMC & SMC MOULDED PARTS CONTENTS 03 04 05 LV Insulators Material Data LV Insulators Type SK Color: Red LV Insulators Type SK 06 07 08 09 10 11 LV Insulators
More informationC&K ET Series Sealed Subminiature Rocker Switches
Features/Benefits Sealed against solder and cleaning process contaminants, bushing & case UL 94V-0 Small footprint saves space RoS compliant Typical Applications Telecommunications Instrumentation Computers
More informationTender Schedule for Electrical Works at Varagani Branch. Sl. No. Particulars Quantity Unit Rate Amount
Tender Schedule for Electrical Works at Varagani Branch Sl. No. 1 Particulars Quantity Unit Rate Amount SITC of following rated Indoor operated wall/floor mounted, cubicle type MV cum APFC Panel suitable
More informationINDIAN INSTITUTE OF TECHNOLOGY KANPUR
INDIAN INSTITUTE OF TECHNOLOGY KANPUR Tender Notice No. 40/Elect./2018 SCHEDULE OF QUANTITY Name of Work: Electrical work for the Clean Room at NCFlexE IIT Kanpur. Name of the Contractor S. No Description
More information7000 Series Miniature Rocker & Lever Handle Switches
Features/Benefits Multi-pole and multi-position Wide variety of actuator and termination options Epoxy terminal-seal compatible with bottom wash cleaning RoS compliant Typical Applications Telecommunications
More informationTEKMEC TEKMEC ABSOLUTE CONTROL PUSH BUTTON STATIONS PUSH BUTTON STATIONS - IN FRP & CAST ALUMINIUM ENCLOSURE STANDARD TAILOR MADE EC TI M I T ME PCMS
ABSOLUTE CONTROL RF M EC TI NT PE CO TEKMEC TEKMEC ON TM TM M I T ME PCMS M11104IN (AN ISO 9001:008 CERTIFIED COMPANY) S - IN FRP & CAST ALUMINIUM ENCLOSURE STANDARD TAILOR MADE S SCOPE & SPECIFICATION
More informationEstimate For The Electrical Works At Pittakayagulla Branch Sl.N Particulars Quantity Unit Rate Amount
Estimate For The Electrical Works At Pittakayagulla Branch Sl.N Particulars Quantity Unit Rate Amount 1 2 Writing for light point/ fan point/ exhaust fan point /call bell point with 1.5 sq.mm FR PVC insulated
More informationDistribution Blocks & Bus-bar Solutions
Distribution Blocks & Bus-bar Solutions Insulated Multi Laminate Flexible Copper Bus-bars Threaded Copper Bus-bars Solid Copper Bus-bars Bus-bar Insulators & Supports Insulated Flexible Copper Braided
More informationELECTRICAL MATERIAL SUPPLY
ELECTRICAL MATERIAL SUPPLY 2018 Seven Electrical Solutions (SES) Introduction With over 6 years of experience in providing material to Middle East market, SES is full-line supplier and distributor of electrical,
More informationAN ISO 9001:2015 COMPANY
AN ISO 9001:2015 COMPANY Eco-Friendly Price List w.e.f. 01/03/2018 IS : 8828 ISO 9001:2008 CERTIFIED ORGANISATION IS : 13779 Introduction Welcome to the world of BillTech, One of the reputed name in the
More informationTender Schedule. Sl. No. Particulars Quantity Unit Rate `
Tender Schedule Estimate for Electrical Works at Savalyapuram Branch(18901) Guntur(District). Sl. No. Particulars Quantity Unit Rate ` 1 Wiring for light point/ fan point/ exhaust fan point/ call bell
More informationRockers Product Selection Guide
s Product Selection Guide Series 7000 E ET T 9000 DA D Switch Type Subminiature Subminiature & Lever andle Poles/Throws,, 3PDT, 4PDT,, 3PDT,, DPST, Max. Current 5 Amps 7.5 Amps 3 Amps 3 Amps 4 Amps Washable
More informationCP Automatic capacitor bank
CP 254 - Automatic capacitor bank STE-CP254_V2_général.doc Page 1 CP 254 - General presentation CP 254 is a range of MV capacitor banks designed to be used in electrical networks up to 36kV. The capacitor
More information35-kV Thru-Bushings F Series (bolt-in) for Air-Insulated to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp
Page 1 2018 Equipment Connection Bus Bar, or Grounded Metal Equipment Plate F Series Mounting Holes ELRIM Cycloaliphatic Epoxy Provides: Nontracking, self-scouring, nonweathering performance Superior dielectric
More informationItem Code Description Unit Qty Total
UNDP ELECTRICITY SECTOR NORTHERN GOVERNORATES Phase XI Item Code Description Unit Qty Total 04-02-00001 Service Pole - 6m, 75mm dia GS Pipe 11250 04-02-00002 9m Tubular Steel Poles complete with all Accessories
More informationKey features. DESIGNS: - Conservator type - Hermetically sealed
Package Substations OTDS manufactures a large range of oil filled hermitically sealed and conservator type transformers to be used in conjunction with our package substations. We are able to utalise the
More informationMV Metalclad Switchgear 4760V-15000V 20KA-63KA. AC Power Circuit Breaker Rating Structure. Test Procedures for Power Circuit Breakers
Contents Key Features and Benefits Codes and Standards Value Addition by Application of PVAC-E GE Components Inside Design Features on PVAC-E Switchgear PVAC-E Switchgear Configuration PVAC-E Switchgear
More informationWe msckolkata are one of the leading traders and Suppliers of high quality assortment of Electrical products, Spares and Allied products.
We msckolkata are one of the leading traders and Suppliers of high quality assortment of Electrical products, Spares and Allied products. Our product assortment is cherished for its high quality standards
More information31-SDMS-01 REV. 03 SPECIFICATIONS FOR
31-SDMS-01 REV. 03 SPECIFICATIONS FOR LOW VOLTAGE DISTRIBUTION PANEL This specification is property of SEC and subject to change or modification without any notice CONTENTS Clauses: Page No. 1.0 SCOPE
More informationTotal Cost Abstract. Project Name : - RDPL, Jaipur. Grand Total
Project Name : - RDPL, Jaipur Total Cost Abstract S. No. Description Amount 1 Metering & Distribution Boxes 2 Earthing 3 Point Wiring & Fixtures 4 Data & Voice Grand Total Project Name : - RDPL, Jaipur
More informationSECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT
SECTION 16400 LOW VOLTAGE DISTRIBUTION EQUIPMENT A. General 1. The University does not accept Series-Rated equipment for power distribution switchboards, distribution panels and branch circuit panelboards.
More informationEMPAC Metal enclosed capacitor bank for wind applications
EMPAC Metal enclosed capacitor bank for wind applications Introduction The EMPAC is a Metal Enclosed Capacitor Bank suitable for voltages between 1 kv and 36 kv for reactive compensation in MV networks
More informationSERIES POWER DISTRIBUTION BLOCKS
62000-69000 SERIES POWER DISTRIBUTION BLOCKS VERSATILE POWER DISTRIBUTION BLOCKS FOR CABLE TERMINATIONS Ferraz Shawmut Power Distribution Blocks afford a safe, convenient way of splicing cables, splitting
More informationPower IT Air Insulated Cubicle Uniswitch
- 1-4/2/2003 Secondary Distribution Switchgear Power IT Air Insulated Cubicle Uniswitch Table of Contents Market segment Ratings New for 2003 Technical features Advantages Market segment Uniswitch Switchgear
More informationches UL File No. E101598
Instrument Transformers, Inc. Series Series 95 95 Swit Switches ches UL File No. E101598 INSTRUMENT AND CONTRC ONTROL OL s Instrument and Control Switch is a heavy-duty rotary switch that satisfies the
More informationQuality Products, Prompt Service, Trustful Relationships.
SINCE 1989 Quality Products, Prompt Service, Trustful Relationships. KM Industrial Corporation has established itself as a trusted supplier of Electrical, Machinery and Industry Goods for the last 20 years.
More informationUniGear. Technical Guide
UniGear Technical Guide CONTENTS 0 CONTENTS 1.1 Compartments 1/2 1.2 Components of the structure 1/3 1.2.1 Hot-galvanized steel sheet 1/3 1.2.2 Painted steel sheet 1/4 1.2.3 Copper 1/5 1.2.4 Insulating
More informationFuse & Switch. BUCHANAN Terminal Blocks. Product Facts High Density Blocks. Fuse Blocks. Switch Blocks. Common Features of 300 & 0300 Series
Fuse & Switch Product Facts High Density n Fuse and Switch rated 15A and 300V. n High Density 0.36" [9.14] centerline spacing saves panel space; at least 33 circuits per foot. Fuse n Provide in-line circuit
More informationINDIAN INSTITUTE OF TECHNOLOGY KANPUR
INDIAN INSTITUTE OF TECHNOLOGY KANPUR Tender tice. 21/Elect./2018 SCHEDULE OF QUANTITY Name of Work: Construction of second floor above central block at ACES building (SH: Electrical works). Name of the
More informationBills of Quantities and Schedule for the Electrical Works at M/s.Bank of India, Madurai CPC Branch, East Aavani Moola Street, Tamil Nadu.
Bills of Quantities and Schedule for the Electrical Works at M/s.Bank of India, Madurai CPC Branch, East Aavani Moola Street, Tamil Nadu. S.No Particulars Qty Unit Rate Rs Amount Rs Service Connection
More informationEquipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module
transformers and buzzers and bells socket outlets and special supports 042 25 042 52 041 07 042 80 042 85 Pack Cat.Nos Bell transformers dconform to IEC / EN 61558-2-8 Protected against overloads and short
More informationClass H & K Fuse Holders - 250/600 Volt
Class H & K - 250/0 Volt Specifications: Approved for 10,000 Amp Withstand Rating and Short Circuit Current Ratings (SCCR) UL Listed File No. IZLT.E35113 CSA Certified File No. LR21455 RoHS Compliant &
More informationhttps://www.indiamart.com/swastiktool-terminals/
+91-8048003080 Swastik Tool & Terminals https://www.indiamart.com/swastiktool-terminals/ We, Swastik Tool & Terminals are leading Manufacturer, Trader and Supplier of Copper Cable Terminals, Aluminum Cable
More informationTECHNICAL SPECIFICATIONS FOR LT DISTRIBUTION BOX MADE FROM THERMOSETTING PLASTIC HAVING 200 /400 AMP CAPACITY.
TECHNICAL SPECIFICATIONS FOR LT DISTRIBUTION BOX MADE FROM THERMOSETTING PLASTIC HAVING 200 /400 AMP CAPACITY. 1.0 SCOPE: This specification covers the design, manufacturing and testing of LT Distribution
More informationSiemens Com www.alfazalengineering.com Company Introduction Al-Fazal Engineering is Authorized Dealer of Siemens Components supply and Services also we are electrical construction material manufacturing
More informationPractical and completely safe
FUSE RRIERS >>> Practical and completely safe Isolating fuse carriers 058 06 058 28 Dimensions (p. 0) onform to standard IE 60269-2/2. and to NF 63-2. Isolators conform to IE 60947-3. Icc: - 20 k with
More informationMetal Clad Air Insulated Switchgear
Metal Clad Air Insulated Switchgear 1/ SecoGear Metal Clad Switchgear Features Fully metal-clad Equipped with Embedded pole VCB Full Front access (can be installed against wall) Perfect interlocking system
More informationMultiple Limit Switch
Multiple Limit Switch CSM DS_E_1_1 A New Monoblock Multiple Limit Switch Incorporating a ead Box with a Tough ead and Ensuring igh Sealing Performance and a Mechanical Durability of 5,000,000 Operations
More informationName of work : Electrification of PG Block Second Floor in V.P.S.V Ayurveda college Kottakkal.
Name of work : Electrification of PG Block Second Floor in V.P.S.V Ayurveda college Kottakkal. TENDER SCHEDULE -1-1 2 3 4 5 6 7 1 208 Point Wiring for light point/ fan point/ exhaust fan point/ call bell
More informationTerminal Blocks. Section 12. Control Catalog 12-1
CR151K Resilient Modular Terminal Blocks CR151C (top) and CR151A Modular Terminal Blocks DIN-rail Mounted Terminal Blocks (CR151K)...12-2 Product Tables...12-3, 12-4 Accessories...12-3, 12-4 Technical
More informationBenefits. Safety. Durability. Performance. Russellstoll. Heavy Industrial/ Marine
eavy Industrial/ Marine Benefits builds a variety of benefits into one plug, receptacle and interlock system for your application. Safety Waterproof construction: standard neoprene O ringed interior components
More information045 : 2000 CEB STANDARD
045 : 2000 CEB STANDARD LOW VOLTAGE FUSE SWITCH DISCONNECTOR CEYLON ELECTRICITY BOARD SRI LANKA Specification for LOW VOLTAGE FUSE SWITCH DISCONNECTOR CEB Standard 045 : 2000 CEYLON ELECTRICITY BOARD No.
More informationInstallation device. HelaTape. Electrical tapes for sealing, insulation and bundling of cable and conduits.
Electrical tapes for sealing, insulation and bundling of cable and conduits. HellermannTyton offers a wide range of PVC and rubber tapes for sealing, insulation and bundling of cable and conduits. PVC-
More information320A Single Phase URD Meter Loop Installations
320A Single Phase URD Meter Loop Installations Location: The meter loop shall be mounted on the side of the pedestal facing the consumer's lot. (The side being one of the four flat surfaces of the pedestal
More informationFuse & Disconnector. NT Low Voltage Fuse... F01-02 H.R.C Fuse Core... F03
Fuse & Disconnector NT Low Voltage Fuse... F01-02 H.R.C Fuse Core... F0 Fuse Holder... F0-04 J Fuse Link... F05 Fuse Base... F05 Fuse link... F0 Cut Out Fuse... F0 Isolating Switch Fuse... F0 Fuse Disconnector...
More informationVOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS
VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS A. 11 KV SWITCHGEAR 1.0 SWITCHGEAR ASSEMBLY 1.1 Make : 1.2 Type : 1.3 Reference Standard : 1.4 Voltage (Nom./Max.) KV : 1.5 Phase, Frequency No,Hz.
More informationNS Feeder pillar up to 3200A
NS Feeder pillar up to 3200A Advanced technology for low voltage, outdoor distribution Merlin Gerin Modicon Telemecanique Outdoor electrical distribution with advanced technology Merlin Gerin low voltage,
More informationChapter 6 Generator-Voltage System
Chapter 6 Generator-Voltage System 6-1. General The generator-voltage system described in this chapter includes the leads and associated equipment between the generator terminals and the low-voltage terminals
More informationMipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service
No One Does It Like Mipco Mipco Interlocked Reefer Power Outlets are used extensively in port terminals and shipboard applications to provide a safe, watertight electrical connection for refrigerated containers.
More informationGROUP D. Switch & Protective device.
GROUP D Switch & Protective device PYUNGIL Bldg., 147-10, Gwanyang 2-dong, Dongan-gu, Anyang-si, Gyeonggi-do, 431-808, Korea Tel : 82-31-420-0~3 FAX : 82-31-424-7300 www.pyungil.com Pole-mounted SF Insulated
More informationSection 10: Terminal Blocks
Terminal Blocks Section : Terminal Blocks CR151K Resilient Modular Terminal Blocks DIN-rail Mounted Terminal Blocks (CR151K)...-2 Product Tables...-3, -4 Accessories...-3, -4 Technical Data...-5 Outlines
More informationKENYA POWER-MOMBASA BRANCH REPLACEMENT OF AIR-CONDITIONING AND ASSOCIATED WORKS BILLS OF QUANTITIES FOR ELECTRICAL INSTALLATIONS BILL NO
BILL 1 MAINS POWER DISTRIBUTION 2-1 ITEM DESCRIPTION QTY UNIT RATE AMOUNT Supply, install, test, commission and set to work the following:- 1.01 Free-standing purpose made front access sub main switchboard
More informationZucchini busbar ZUCCHINI DISTRIBUTION FUSE BOARD TAP-OFF
Zucchini busbar ZUCCHINI DISTRIBUTION FUSE BOARD TAP-OFF Global strength built on local knowledge Legrand is the global specialist in electrical and digital building infrastructures. Innovation is the
More informationS H A D E S ELECTRICAL DB MANUFATURING
CORPORATE BROCHURE S H A D E S ELECTRICAL DB MANUFATURING S H D E S ELECTRICAL DB MANUFACTURING L.L.C. www.shadesdb.com I N T R O D U C T I O N Welcome to SHADES, this portfolio has been designed to give
More informationFuseology. Fuse Holders, Fuse Blocks, Power Distribution Blocks & Surge Suppression. Optima Fuse Holders & Overcurrent Protection Modules.
Fuseology Fuse Holders, Fuse Blocks, Power Distribution Blocks & Surge Suppression Optima Fuse Holders & Overcurrent Protection Modules Compact, full-featured modules that deliver Type 2 coordinated protection,
More informationCSP Circuit Breaker Three Phase
General Information : LR Breaker SQR Breaker LQR Breaker, HQR Breaker Wall-Mounting Type CSP Circuit Breaker Three Phase Three Phase CSP Circuit Breaker For Distribution Transformers General Information
More informationGas Insulated Switchgear
Gas Insulated Switchgear Your partner in energy solutions CG Electric Systems Hungary CG Electric Systems Hungary (previously known as Ganz Electric) has a history of over a 130 years as a high technology
More informationMDS2 Series. Modular Distribution Systems. Introduction 8-Position Configuration Decision Tables
MDS2 Series Modular Distribution Systems Introduction 8-Position Configuration Decision Tables 207 208 209 MDS2 Series Modular Distribution Systems INTRODUCTION Sensata Technologies provides circuit-on-demand
More informationGeneral characteristics
Multipole Industrial Connectors General characteristics The multipole connectors for industrial purposes are used in electric and electronic machinery, robots, electric panels, control equipments and wherever
More informationVoltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]
BasisBlock MC 1 Standards and Regulations IEC 62271-200 ; VDE 0671-200 ; BS EN 62271-200 Technical Data MC1-12 MC1-24 Voltage Rated operating voltage [kv] 12 24 Rated power frequency withstand voltage
More informationBusbar Systems Accessories
Busbar Systems Accessories SU1 SU Busbar Material: Thermoplastic Polyester Rated voltage up to 1000V, 50-60Hz Inserts can be used to facilitate the use of smaller busbar SU Busbar holders - Rated up to
More informationLocal Control Station
Local Control Station As per table given below Ex'd', IIC, IP-66, FLP/WP Local Control Station and Switch MFPB/302/IIC-IEC MFPB/302/IIC-IEC MFPB/302/IIC-IEC MFRS/104/I/IIC-IEC MFRS/104/IIC-IEC A B C D
More informationME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position
LET S BE PACIFIC November 0 Volume Number 5 ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position Federal Pacific has the capability to engineer, fabricate and assemble
More informationUniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions
UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions ABB a global leader ABB is a global leader in power and automation technologies that
More informationCable arrangement 15 Preparation for cable installation. 15 Installation of the cables 16 Finishing of the cable installation. 17 Examples.
Transportation and storage.. 3 General. 3 Unpacking at installation site....... 3 Transfer of cubicles at installation site... 3 Weight.. 4 Temporary storage. 4 Erection at site 5 General. 5 The switchgear
More informationVersaRupter 5-38 kv Load Interrupter Switch. Technical Guide
VersaRupter 5-38 kv Load Interrupter Switch Technical Guide NOTICE Components in this catalog are intended for use by switchgear assemblers engaged in original equipment manufacturing. All sales are subject
More informationS1-568, S1-1068, S1-1568
S1-568, S1-1068, S1-1568 Resistance range up to 35 TΩ 8 ma noise rejection plus 4 filters Safety up to CATIV 1000V to 4000 m Rapid charge Li-ion battery meets IEC62133 Operate with flat battery from an
More informationSchool of Electrical and Information Engineering. ELEC High Voltage. University of Sydney. Dr Keith Mitchell. Engineering
University of Sydney School of Electrical and Information Engineering Dr Keith Mitchell ELEC 5205 - High Voltage Engineering ELEC 5205 - High Voltage Engineering 3. Switchgear Types of Power System Switchgear
More information15 kv and 25 kv Thru-Bushings
Page 1 2001 ELRIM Cycloaliphatic Epoxy Provides: Nontracking, self-scouring, nonweathering performance Superior dielectric strength, dielectric loss and power factor Choice of shapes allows design innovation
More informationHigh voltage in motion Environmentally friendly circuit breakers and economic long-rod insulators
High voltage in motion Environmentally friendly circuit breakers and economic long-rod insulators Christian Hückler, Sales Manager Air-Insulated Switchgears siemens.at/future-of-energy High voltage in
More information31-SDMS-02 REV. 01 SPECIFICATIONS FOR
31-SDMS-02 REV. 01 SPECIFICATIONS FOR LOW VOLTAGE DISTRIBUTION PILLAR This specification is property of SEC and subject to change or modification without any notice C O N T E N T S S. NO. D E S C R I P
More informationMIT515, MIT525, MIT1025, MIT1525
MIT515, MIT525, MIT1025, MIT1525 Measures up to 30 TΩ Safety rated up to CAT IV 1000 V to 3000 m Unique dual-case design - additional user protection Operates from battery or a.c. mains supply Rapid charge
More informationWESTERN ELECTRICITY SUPPLY COMPANY OF ORISSA, WESCO. GUARANTEED TECHNICAL PARTICULARS 1 of 2
Sl. No. WESTERN ELECTRICITY SUPPLY COMPANY OF ORISSA, WESCO GUARANTEED TECHNICAL PARTICULARS 1 of 2 REQUIREMENTS 11 Kv, 200 Amps, A.B Switches. Particulars 1 Maker's name and Country of origin. 2 Type
More informationSUBSTATION VACUUM CIRCUIT BREAKER (38KV)
SUBSTATION VACUUM CIRCUIT BREAKER (38KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities
More informationMoisture-proof cable branch boxes Ceiling distribution boxes Lamp suspension boxes Wall boxes Concrete wall boxes and accessories
Branch and lustre terminals Apparatus and light terminals Porcelain terminals Screwless terminals Flat plug terminals Flat plug branch terminals Mains branch terminals Connection terminals Earthed wire
More informationSUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)
SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities
More informationSUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)
SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products
More informationThree-Phase Pole Mounted Recloser
Three-Phase Pole Mounted Recloser Page 1 of 8 Table of Contents 1 GENERAL... 3 2 CONSTRUCTION... 3-5 3 BUSHINGS... 5 4 LINE CONNECTOR... 5 5 TOOLS....5 6 NAMEPLATES..6 7 PAINT... 6 8 EXTERNAL HARDWARE
More information37T Series Moisture Resistant Temperature Controls
37T Series Moisture Resistant Temperature Controls Moisture Resistant Temperature Control The 37T series of 3/4 (19mm) bimetal disc temperature controls from Therm-O-Disc offers proven reliability in a
More informationLOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES TECHNICAL DATA
LOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES Complying with BSEN60947 and IEC 408 the RDMP range of rotary cam switches are suitable for on load switching of general distribution
More informationNXPLUS C Single busbar. Maintenance-free for lifetime
NXPLUS C Single busbar Maintenance-free for lifetime Energy Distribution Welcome! Page 2 Content Overview Technical data Typicals Panel design Circuit-Breaker panel Busbar Operation Metering Low-voltage
More informationSTANDARD SPECIFICATION FOR. LIGHTING AND DC DISTRIBUTION PANELS WITH MCBs DOCUMENT NO: 44LK-5100/E.02/011
Page 1 of 6 STANDARD SPECIFICATION FOR LIGHTING AND DC DISTRIBUTION PANELS WITH MCBs Rev No. Issue Date Pages Rev Description Prepared By Checked By Approved By 0 15.07.2008 6 Issued for FEED MSJ VDV VDV
More informationC&K 1000 Series Miniature Slide Switches
Miniature Switches Features/Benefits Variety of actuators and terminations Panel mount tabs available Epoxy terminal seal compatible with bottom-wash cleaning RoHS compliant Typical Applications Test &
More informationControl Circuits Connectors Type SK & SKW Overview
Control Circuits Connectors Type SK & SKW Overview 20 Amp, 250 Volts AC or DC, 600 Volts AC Max. Rating Load-Breaking Multi-Circuit Receptacles, Plugs, Connectors and Inlets Features and Benefits Type
More informationADVANCE System ADVANCE SYSTEM IP66 MODULAR SYSTEM FOR COMBINATION UNITS VERSIONS MODULE 136 MODULE 106. t. 56. Without protective devices
ADVANCE System ADVANCE SYSTEM IP66 MODULAR SYSTEM FOR COMBINATION UNITS Without protective devices Interlocked-switch socket outlets QUADRA Series socket outlets For 16 and 32 A currents Protection degree
More informationBILL OF QUANTITY (BOQ) FOR ELECTRICAL WORKS BOGAPURAM BRANCH
BILL OF QUANTITY (BOQ) FOR ELECTRICAL WORKS BOGAPURAM BRANCH SL NO. DESCRIPTION OF ITEM / WORK UNIT QTY PART - A : ELECTRICAL WORKS 1 1 Energy Meter Cubicle : a Fabrication, Supply, Installation, testing
More information25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp
Page 1 2018 Grounded Metal Equipment Plate Equipment Connection Bus Bar or Other Component 15 kv or 25 kv Separable Insulated Connector (elbow) Equipment Connection Power Cable Power Cable ELRIM Cycloaliphatic
More informationTransformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC
Transformer High Current Bushings Type CFPT & CFCT 36kV up to 40kA IEC 60137-2008 High current bushings for transformer Features Bushing Type CFPT version Porcelain Insulator Trench RIG technology for
More information5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application
The most advanced Arc-Resistant Switchgear, designed and built to provide maximum safety in the event of an Internal Arcing Fault. 5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application Page 1
More informationElectronic Circuit Breaker ESS20-0..
Electronic Circuit Breaker ES-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode
More information35-kV 200-kV BIL Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp
Page 1 2018 Grounded Metal Equipment Plate Equipment Connection 35 kv Separable Insulated Connector (elbow) Bus Bar or Other Component Grounded Metal Equipment Plate Equipment Connection Bus Bar or Other
More informationBETA Low-Voltage Circuit Protection
BETA Low-Voltage Circuit Protection /2 Introduction Miniature Circuit Breakers /4 5SP and 5SY miniature circuit breakers / 5SJ6...-.KS miniature circuit breakers with plug-in terminal /21 5SY6 0 miniature
More informationMETAL ENCLOSED STANDARDIZED MEDIUM VOLTAGE SWITCHBOARDS, INSULATED IN AIR AND SF6 GAS UP TO 36KV
METAL ENCLOSED STANDARDIZED MEDIUM VOLTAGE SWITCHBOARDS, INSULATED IN AIR AND SF6 GAS UP TO 36KV ATR VERSION MIX is a MV modular protected panel with metallic envelope suitable to can also be designed
More informationYOUR KEY ENERGY EFFICIENCY PARTNER CAST RESIN DRY-TYPE TRANSFORMERS
YOUR KEY ENERGY EFFICIENCY PARTNER CAST RESIN DRY-TYPE TRANSFORMERS 1 TABLE OF CONTENTS ABOUT SVEL GROUP CAST-RESIN TRANSFORMERS ACCESSORIES AND OPTIONAL EQUIPMENT ENCLOSURE AND HOUSING TESTS AND QUALITY
More informationRiLine mm system technology for the global market
60 system technology for the global market 02 RiLine60 Busbar systems 3 and 4 pole Support + bars + contact hazard protection Flat copper bar system, see 276 in HB 33 PLS busbar system, see 278 in HB 33
More informationR6F30A1S R6F30A1S 1P 60A 600V Fuse BLK. Features. Long Description
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Catalog Number Manufacturer Description Weight per unit Product Category Features Clip Type Fuse Current Rating Fuse Type
More informationSteel Conduits Conduit Fittings Flexible Conduits
Conduits Conduit Fittings Flexible Conduits CONTENT 1. INTRODUCTION VOLTECX products introduction and selecting VOLTECX 2. STEEL CONDUITS VOLTECX BS4568: Part 1: 1970 (Class 4) Conduit IEC 61386-21:2004;
More informationLIST OF EDD DESCRIPTION/ SPECIFICATION AS 19 TH OCTOBER 2016
No Description/ Specification Amendment 1 EDD 1 :2008 11/0.415 kv Distribution Transformer, Oil Filled - 2 ED 2 :1987 The Galvanization of Iron and Steel, Articles Other Than Steel Wire - 3 ED 3 :1979
More information