Fuse & Disconnector. NT Low Voltage Fuse... F01-02 H.R.C Fuse Core... F03

Size: px
Start display at page:

Download "Fuse & Disconnector. NT Low Voltage Fuse... F01-02 H.R.C Fuse Core... F03"

Transcription

1 Fuse & Disconnector NT Low Voltage Fuse... F01-02 H.R.C Fuse Core... F0 Fuse Holder... F0-04 J Fuse Link... F05 Fuse Base... F05 Fuse link... F0 Cut Out Fuse... F0 Isolating Switch Fuse... F0 Fuse Disconnector... F07 HG2B Fuse Disconnector... F07 High Voltage Cutout... F08 Lightning Arrester... F09

2 NT NT Low Voltage Fuse 1. Application NT low voltage H.R.C. fuse features light in weight, small in size, low in power loss and high in breaking capacity. This product has been widely used in overload and short circuit protection of electric installation. This product conforms to IEC 029 standards with all of the rating at the world advanced level. 2. Specifications Fuse link Fuse base NT00C NT00 NT0 current voltage (V) 0 power loss Weight (kg) (W) current Weight (kg) NT00C 0. Sist , 00 0, 00 NT00 0. Sist , 00 NT0 0.2 Sist F-01

3 NT 2. Specifications Fuse link Fuse base current voltage (V) power loss (W) Weight (kg) current Weight (kg) NT1 NT 1 0, NT Sist , Sist NT , Sist NT Sist NT4 NT00 P P Fuse Puller F-02

4 H.R.C H.R.C Fuse Core 1. Application The fuses links having cylindrical contact caps are designed for protecting electrical distributing installations of rated voltage of V AC. with rated current up to 1A against damage due to overload and short circuit. Fuse links with the striker are supplied for the purpose of protecting motors against motor single phasing operation when fitted in fuse isolators. RO14 RO RO1 RO21 RO22 2. Specifications Dimension Current gg ar (mm) RO14 RS x 1.5 1, 2, 4,,, 1, 20 RO14A RO RO1 RS14A RS RS1 8.5 x 2 x 8 1, 2, 4,,, 1, 20 2, 4,,, 1, 20,, 2, 4,,, 1, 20,,,,, RO17 RO21 RO22 RS17 RS21 RS22 22 x 58 DII DIII, 1, 20,,,,,,, 2, 4,, 8,, 1, 1, 20, 5,,, RO2 RS2 D01 D02 2-,, 1 20,, 5,, RO2 D0, Fuse Holder 1. Specifications Current A A No. of poles 1P+N, P, P+N 1P, 1P+N, 2P, P, P+N Size of fuse link D02 2.Dimension RD- 1P+N A A 1P+N A 1P Current No.of poles Conductor crosssection mm 2 No. of spacing units per mm RD- A A 1P+N P A 1P RD- P A A 1P+N RD- A A 2P P A P+N F-0

5 RT Fuse Holder RT RT-X 1P RT- 1P RT- 2P RT- P RT- 1P RT- 2P RT- P RT-X 1P RT-X 2P RT-X P RT-X 1P RT-X 2P RT-X P Assorted Fuse x 8 x 8 Voltage (V) Current Weight (kg) A Dimension (mm) B C D E RT-/2P RTM-X/P RTL RTL- RTL-1 Assorted Fuse 22 x 58 Number of Poles 1, 2,, 4 Insulation Voltage (V) 90 Conventional heating current 1 A1 8 Dimension (mm) A2 B H H2 4 RTL HG0 HG0- HG0-1 Assorted Fuse 22 x 58 Number of Poles 1, 2,, 4 Insulation Voltage (V) 0 Conventional heating current A A2 Dimension (mm) B H H2 2 9 ød Dimension HG0 RTL HG0 F-04

6 Fuse J J Fuse Link 1. Specifications size 7mm 8mm 1 /4 92mm 5 /8 current Fuse Base 1. Specifications RL- RL- Voltage 0V 0V Current of Fuse A A Current of Fusant 2,4,,,1,20,A 5,,A RL- RL- Breaking Current KA cosø= kg KA cosø= kg Overall dimension x 4 x 89 x 54 x Weight 0.20kg 0.kg 2. Dimension E27 P Busbar thickness: t=5mm or mm a=mm with E27 P/A 57mm with E P/A E P Size E27 P E P a(1x) 57 b(2x) E27 P/E P Veitrcal type -J F-05

7 Fuse Fuse link Fuse link 1.Specification Dimension mm 8.5 x 1.5 x 8 22 x 58 0 x 58 current 2,4,,,1 2,4,,,1,20,, 2,4,,,1,20,,,,,,1,20,,,,,,,,,,1 L Hamx ØC mm 1.5± ±0.1 ±0..5.±0.1 51± ±0.1 58± ±0.1 58± ±0.1 0# 0/A # 1P+N A Cut Out Fuse 1. Application FS cutouts are made of high grade phenolic moulding power having high mechanical and dielectric strength. The body possesser non-hygroscopic and non-tracking qualities. Terminal contracts are of tinned brass with phosphor bronze back up compression spring capable of providing flawless service even after years of use. It has features like: all components are inter-locked. Sealing provision to aviod unauthorised access. Common body from amps to amps. Terminal are suitable for aluminium/copper conductors upto 5sq.mm loop in and loop out cabling contacts available. FS insulated service cutouts conform to BS standard SR H fuses conform to BS The available current is 0# 0/A, # 0/A, # A, # 1P+N 0/A, # 1P+N A. Isolating Switch Fuse 1. Application The product is used in distribution circuit and motor circuit of current Hz, rated operational frequency 0V under, and rated current -0A, also used in high-short-circuit as power switch, isolating switch and emergency switch protecting circuit. Fitted with NT(RT1)fuse. It conforms to IEC HR5 HR 2. Spcifications Number of Main Poles Insulation Voltage AC (V) Operational Voltage (V) Operational Current Making Capacity Breaking Capacity Fused Short Circuit Current (KAr.m.s) Max.Fuse-Link Fuse (NT0) V AC-2 0V AC-22 V cosø0.5 AC-2 0V cosø0.5 AC-22 V cosø0.5 AC-2 0V cosø0.5 AC-22 V AC-2 0V AC-22 Mechanical Endurance/Electrical Endurance (Operations) Auxiliary Switch (V AC-)VA F-0

8 HR17 Fuse Disconnector 1. Specifications Switch Rating Heat Current Number of Poles, 4 Assorted Fuse NT00 NT1 NT Current 4,,,1,20,,,5,,,,,,1,10,,1,10,,224,2 1,10,,224,2,00,,55,0,5,0,5,0,0 HR17 P 2. Dimension HR17 HR17-10/0 HR17-2/0 HR17-0/0 HR17-0/0 HR17-10/ HR17-2/ HR17-0/ HR17-0/ Assorted Fuse NT00 NT1 NT NT00 NT1 NT A B C D a b øc ø7 ø7 HR17 4P. Dimension HR HR HR-10 HR-2 HR-0 HR-0 Assorted Fuse NT00 NT1 NT A B C D E a b øc ø7 ø9 ø9 ø9 HG2B Fuse Disconnector HG2B-A HG2B-S 1.Specifications Assorted Fuse HG2B-10A NT00 HG2B-2A NT1 HG2B-0A HG2B-0A NT Switch Rating Heat Current Current 4,,,1,20,,,5,,,,,,1,10,,1,10,,224,2 1,10,,224,2,00,,55,0,5,0,5,0,0 F-07

9 RS,RW,RH High Voltage Cutout 1. Description Mounting Bracket Long Bolts Mounting Bracket External-Tooth Lock Washer Porcelain Insulator Lock Washer Upper Connection Fuse Holder Lower Connection Lifting Eye Connectors Steady Contacts Load Break Tool Attack Hook Opening Eye KV-KV 2. Specification Voltage (KV) RS-7 RS-7 RH-8 RH-8 RH-C RH-C RH-A 5 RH-A 5 Current Breaking Current Impulse Voltage (BIL) 1 1 Power- Frequency Withstand Voltage (KV) Crawling Distance 20m/m 20m/m 20m/m 20m/m 0m/m 0m/m 0m/m 0m/m Weight (kg) KV-KV R-98 R-98 R-97 R-97 RH-8 RH m/m m/m 0m/m 0m/m 0m/m 0m/m KV RW-F/ RW-F/ RW11-F- RW11-F/ PRWG-F/ PRWG-F/. Dimension m/m 20m/m 0m/m 0m/m m/m m/m KV-5KV F-08

10 YHWS,Y5C Lightning Arrester 1. YHWS1 Lightning Arrester YHWS1 YHWS-.8/17 YHWS-7./0 YHWS-/0 YHWS-.7/ YHWS-17/45 System Voltage (KV) Lightning Arrester voltage (KV) Lightning Arrester Continuous Operating Voltage (KV) DC 1mA Voltage (KV) 7.5 Nominal Discharge Current Wire (KV) Square Wage Impulse Current Endurance 2. Dimension. Y5C-YC Lightning Arrester Y5C-YC Y5C- YC- Y5C- YC- Y5C-24 YC-24 Y5C- YC- Y5C- YC- Voltage (KV) Power Frequency Discharge Current KV Impulse Discharge Voltage KV /20 μ S Residual Voltage for Lightning Impulse KV Square Wave Through Discharge 1 8/20 μ S Front-of-Wave Impulse Max Current 20 Times (KV) Impulse Max Sparkover Voltage (KV) F-09

These fuse-links are manufactured according to the following lnternational standards:cei 32.1 and 4, IEC A NFC UNE 21.

These fuse-links are manufactured according to the following lnternational standards:cei 32.1 and 4, IEC A NFC UNE 21. Miniature Fuse Link pplication The fuse-links for industrial and similar applications, consist of body in steatite and can tolerate very high thermical changes, which occur inside of it at the cut off

More information

W DATA SHEET: COMBINED FAULT-CURRENT PROTECTIVE SWITCH, SERIES BOLF, 3P+N

W DATA SHEET: COMBINED FAULT-CURRENT PROTECTIVE SWITCH, SERIES BOLF, 3P+N W DATA SHEET: COMBINED FAULT-CURRENT PROTECTIVE SWITCH, SERIES BOLF, 3P+N W SCHRACK-INFO Typ A (pulse) Connection on both sides are possible Tripping independent of line voltage Additional connection capability

More information

BETA Fuses and Fuse Systems

BETA Fuses and Fuse Systems Introduction Overview Application LV HRC fuses are used for installation systems in non-residential, commercial and industrial buildings as well as in the switchboards of power supply companies. Fuses

More information

Cylindrical fuse-link

Cylindrical fuse-link Cylindrical fuse-link Technical data Rated voltage Rated current Rated frequency Rated breaking capacity Characteristics ody material 00 V AC, 00 V AC, 90 V AC CH 8 - A/00 V CH 0,- A/00 V, 0-3 A/00 V CH

More information

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT

PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT PRECISE HIGH VOLTAGE DISTRIBUTION FUSE CUTOUT COS 38kV 100A 8kA asym. Type PGC Parallel groove terminal bronze with tin plated NEMA Bracket type B Upper contact copper with silver plated Cap - Cast bronze

More information

Euroload Changeover Switch

Euroload Changeover Switch Euroload Features: Quick make & quick break mechanism. High electrical & mechanical endurance. Advance neutral. Enclosed housing to avoid dust ingress. Staggered terminals upto 800A. Load and Line reversibility.

More information

Power distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly

Power distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly NH fuse-switch disconnectors, size 000 Version -pole, cable outlet at the top/bottom For the use of fuse inserts to EN 60 - Technical specifications to IEC/EN 60 947-, see chapter -5, page 6 see chapter

More information

RESIDUAL CURRENT CIRCUIT BREAKER

RESIDUAL CURRENT CIRCUIT BREAKER Quality Features Mid Trip - Different knob position to indicate whether the device is Switched OFF by a fault or Switched OFF manually Inscription Window - Ensures circuit identification and hence reduces

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

Fuse switch disconnectors

Fuse switch disconnectors SWITCHGEAR RBK Fuse switch disconnectors intended for distribution of electricity and protection of electrical equipment against short-circuits and overloads, with industrial fuse links ENERGY SAFELY SWITCHED

More information

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV Switch Disconnectors Introduction Siemens AG 2010 Overview 3NP5 0 3NP5 2 3NP5 fuse disconnector range 3NP5 4 SENTRON 3NP5 fuse disconnectors are controls for the occasional manual ing/isolating of loads

More information

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. . 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s 0090 00/01/02/06/07/11/12/13/14 0/01/02/06/07/11/12/13/14/18/19/23/24/25/26/ /18/19/23/24/25/26/45/46 45/46 0090

More information

Motorized switch-disconnectors OTM 40 to 125 Amperes

Motorized switch-disconnectors OTM 40 to 125 Amperes Motorized switch-disconnectors OTM to 125 mperes With the new range of motorized-switch disconnectors, BB offers now a full range from to 2500 mperes. Thanks to the design, OTM...125 are a good solution

More information

DX³ RCCBs - ID 4P up to 100 A

DX³ RCCBs - ID 4P up to 100 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ s - ID CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

2013 JEAN MÜLLER Products

2013 JEAN MÜLLER Products 2013 JEAN MÜLLER Products Company JEAN MÜLLER JEAN MÜLLER was founded in 1897 in Germany, when the applications of electricity were still in their very early days. The company chose as its basic activity

More information

Cylindrical fuse-link

Cylindrical fuse-link ylindrical fuse-link Technical data Rated voltage Rated current Rated frequency Rated breaking capacity haracteristics Body material 00 V A, 500 V A, 90 V A H 8-5 A/00 V H 0,5- A/500 V, 0-3 A/00 V H -5

More information

045 : 2000 CEB STANDARD

045 : 2000 CEB STANDARD 045 : 2000 CEB STANDARD LOW VOLTAGE FUSE SWITCH DISCONNECTOR CEYLON ELECTRICITY BOARD SRI LANKA Specification for LOW VOLTAGE FUSE SWITCH DISCONNECTOR CEB Standard 045 : 2000 CEYLON ELECTRICITY BOARD No.

More information

BETA Low-Voltage Circuit Protection

BETA Low-Voltage Circuit Protection BETA Low-Voltage Circuit Protection /2 Introduction Miniature Circuit Breakers /4 5SP and 5SY miniature circuit breakers / 5SJ6...-.KS miniature circuit breakers with plug-in terminal /21 5SY6 0 miniature

More information

Utilisation category gl/gg 500VAC with combi indicator

Utilisation category gl/gg 500VAC with combi indicator DIN-fuse-links DIN fuse-links are used for the protection of electrical installations and equipment and are common for a wide area of applications. Standardised characteristics, technical data and dimensions

More information

vertical fuse switch disconnectors

vertical fuse switch disconnectors SWITCHGEAR ARS vertical fuse switch disconnectors - touch protection IP 30 from the front - fibre glass extra strenghtened, self extinguishing thermoplastics - double clearance between open contacts -

More information

TX³ RCCBs 2P up to 100 A

TX³ RCCBs 2P up to 100 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 TX³ RCCBs CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

GROUP D. Switch & Protective device.

GROUP D. Switch & Protective device. GROUP D Switch & Protective device PYUNGIL Bldg., 147-10, Gwanyang 2-dong, Dongan-gu, Anyang-si, Gyeonggi-do, 431-808, Korea Tel : 82-31-420-0~3 FAX : 82-31-424-7300 www.pyungil.com Pole-mounted SF Insulated

More information

RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLE

RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLE OLE Residual current circuit breakers RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLE OLE-10B-1N-030AC The device is a combination of residual current circuit breaker and circuit breaker.

More information

Section 2 - Substation Switchgear

Section 2 - Substation Switchgear Switchgear & Protection : Section 2 Section 2 - Table of Contents Section/Page Introduction to DB36 - D362 Disconnectors (36kV - 362kV)... 2-2 Popular Options For DB36, DB72 & DB145... 2-3... 2-3 Popular

More information

TABLE OF CONTENTS FOREWORD... 2 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS... 3

TABLE OF CONTENTS FOREWORD... 2 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS... 3 TITLE SPECIFICATION FOR MEDIUM VOLTAGE DATE: FEBRUARY 2015 PAGE: 1 OF 25 TABLE OF CONTENTS Page FOREWORD... 2 INTRODUCTION... 3 1 SCOPE... 3 2 NORMATIVE S... 3 3 DEFINITIONS AND ABBIATIONS... 3 4 REQUIREMENTS...

More information

Miniature Circuit Breaker

Miniature Circuit Breaker Introduction - Miniature Circuit Breaker (MCB) SALIENT FEATURES SALIENT FEATURES Standards MCBs conform to the latest standard IS 8828: 1996/IEC: 898 1995 Mid-Trip Position The Mid trip position of the

More information

Fuse switch disconnectors

Fuse switch disconnectors SWITCHGEAR 62 RBK pro Fuse switch disconnectors designed for distribution of electricity and protection of electrical equipment against short-circuits and overloads with industrial fuse links. ENERGY SAFELY

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

Range : 20A, 32A, 63A & 100A in front connection, bus bar connection & rear connection versions.

Range : 20A, 32A, 63A & 100A in front connection, bus bar connection & rear connection versions. 164 Fuse Holder consisting of carrier and base for mounting fuse links have been in use for long. Keeping operators safety and ease / reliability of removal in mind, a complete range of unique CAM operated

More information

ASL09..S 3-pole Contactors - Spring Terminals

ASL09..S 3-pole Contactors - Spring Terminals 4 kw 5 hp ASL09..S 3-pole Contactors - Spring DC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Low coil consumption, - Polarity on the coil

More information

Varius SUMMARY OF MODELS

Varius SUMMARY OF MODELS SUMMARY OF MODELS Type 10 14 22 OPT22/OPT20 OPVF10 Rated operating current I e / Rated current I n 32 A / - 63 A / - 125 A / - 63 A / - - / 30 A Rated operating voltage U e / Rated voltage U n AC 690 V

More information

CATALOG. EasyLine XLP Fuse Switch Disconnector poles

CATALOG. EasyLine XLP Fuse Switch Disconnector poles CATALOG EasyLine XLP Fuse Switch Disconnector 1-2-3-4 poles 2 E A S Y L I N E X L P F U S E S W I TC H D I S C O N N E C TO R 1-2 - 3-4 P O L E S Contents 004 005 Introduction EasyLine XLP 006 007 Introduction

More information

D509E. Manual Motor - Starters

D509E. Manual Motor - Starters D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors

More information

Vistop TM isolating switches 63 to 160A

Vistop TM isolating switches 63 to 160A DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary

More information

Connecting sets CS-FS CS-FS123-WD. Connecting space covers OD-FS00-.. OD-FS123-KP. Adapter for parallel outlet - HP-SE/K

Connecting sets CS-FS CS-FS123-WD. Connecting space covers OD-FS00-.. OD-FS123-KP. Adapter for parallel outlet - HP-SE/K Varius SUMMARY OF MODELS OF FUSE-RAILS Type FSR00 FSR1 FSR2 FSR3 Rated operating current I e 160 A 250 A 400 A 630 A Rated operating voltage AC/DC U e 690 V 690 V 690 V 690 V Size 00 1 2 3 Busbar spacing

More information

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved

More information

Technical Brochure. Rotary Type Installation Switches A, 500 V. Brochure OT_M 22 GB D Low Voltage Products

Technical Brochure. Rotary Type Installation Switches A, 500 V. Brochure OT_M 22 GB D Low Voltage Products 94 D 5384 Technical Brochure Rotary Type nstallation Switches 16...160 A, 500 V Brochure T_M 22 GB 99-08 Low Voltage Products 9809CD03 Rotary Type nstallation Switches 16 A...160 A ew features for installation

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

DPX moulded case circuit breakers

DPX moulded case circuit breakers BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.

More information

LIGHTNING EQUIPOTENTIAL BONDING ISOLATING SPARK GAPS. EXFS L / EXFS KU for explosive Areas

LIGHTNING EQUIPOTENTIAL BONDING ISOLATING SPARK GAPS. EXFS L / EXFS KU for explosive Areas EXFS L / for explosive Areas For indirect connection/earthing of functionally separate system parts at lightning strikes Unit for lightning equipotential bonding according to IEC 61024-1 for hazardous

More information

RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLFE (6 ka)

RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLFE (6 ka) Residual current circuit breakers MINIA RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLFE ( ka) The device is a combination of residual current circuit breaker and circuit breaker For

More information

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec Catalog HA 41.43 Edition 2018 Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable Medium-Voltage Switchgear siemens.com/simosec Application Typical uses R-HA41-135.tif R-HA40-112.tif R-HA41-115.tif

More information

Technical Specification for 33 KV 200 AMPs,H.G,Fuse set.

Technical Specification for 33 KV 200 AMPs,H.G,Fuse set. Technical Specification for 33 KV 200 AMPs,H.G,Fuse set. 1. SCOPE:- This specification covers the manufacture, testing and supply of 33KV 200 Amps, H.G. Fuse sets 2. The 33 KV H.G. Fuses shall be suitable

More information

SD Series Non-Fused Load Switches

SD Series Non-Fused Load Switches SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load

More information

CP Automatic capacitor bank

CP Automatic capacitor bank CP 254 - Automatic capacitor bank STE-CP254_V2_général.doc Page 1 CP 254 - General presentation CP 254 is a range of MV capacitor banks designed to be used in electrical networks up to 36kV. The capacitor

More information

Outdoor disconnectors FTr (previously 6400 and 6410) single- and three-pole design rated voltage 25 and 38.5 kv rated current 400 and 630 A

Outdoor disconnectors FTr (previously 6400 and 6410) single- and three-pole design rated voltage 25 and 38.5 kv rated current 400 and 630 A Outdoor disconnectors FTr (previously 6 and 6410) single- and three-pole design rated voltage 25 and 38.5 kv rated current and 6 A 1 Outdoor disconnectors Outdoor disconnectors, produced in accordance

More information

3TM Vacuum Contactors

3TM Vacuum Contactors Catalog Extract HG 11.23 Edition 2016 Catalog Extract Medium-Voltage Equipment siemens.com/3tm R-HG11-343.psd 2 Siemens HG 11.23 2016 Contents Medium-Voltage Equipment Catalog Extract HG 11.23 2016 Contents

More information

Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers:

Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers: 4 (Four) Pole Monoblock: Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers: Designed and manufactured in accordance with EN 50336:2002 and BS 2562: 1979 1 Introduction:

More information

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR ANGLER SWITCHING DEVICES CONTENTS 1. General 2. Switchgear Types - Switch Disconnector - Disconnector 3. Cubicle Types - Cubicle with Switch Disconnector

More information

3NP1 Fuse Switch Disconnectors up to 630 A

3NP1 Fuse Switch Disconnectors up to 630 A Switch Disconnectors 3NP1 Fuse Switch Disconnectors up to 630 A Introduction Overview All key product features at a glance available for all sizes Connection of circular conductors and laminated conductors

More information

References 4 Fuse carriers

References 4 Fuse carriers References components 000_ -pole basic blocks Rating Cartridge fuse size umber of early break contacts () Single-phase protection device () Reference () Connection by spring terminals A 0 x 8 () Without

More information

DX³ 4-pole RCBO 6000 A/10 ka

DX³ 4-pole RCBO 6000 A/10 ka 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ 4-pole RCBO CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

DBM Range 1500VDC (13,5kA to 20kA)

DBM Range 1500VDC (13,5kA to 20kA) Load Break Switches For more than 100 years, Mersen has been providing the market with safe, reliable and longer life time on-load disconnectors.these devices offer high performances and robustness for

More information

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable www.siemens.com/medium-voltage-switchgear Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable Medium-Voltage Switchgear Catalog HA 41.43 2012 Answers for infrastructure and cities. Neue Bilder

More information

CGMCOSMOS. Reliable innovation. Personal solutions. Fully gas insulated modular and compact (RMU)system.

CGMCOSMOS. Reliable innovation. Personal solutions. Fully gas insulated modular and compact (RMU)system. MV Switchgear for CGMCOSMOS Fully gas insulated modular and compact (RMU)system Up to 24 kv Up to 27 kv mediumvoltage mediumvoltageag AG Langackerstrasse Langackerstrasse 25 25 CH CH 6330 6330 Cham Cham

More information

RESIDUAL CURRENT CIRCUIT BREAKERS OFE (6 ka)

RESIDUAL CURRENT CIRCUIT BREAKERS OFE (6 ka) Residual current circuit breakers RESIDUAL CURRENT CIRCUIT BREAKERS OFE ( ka) Standard type for common use in building and housing installations up to 3 A, 230/400 V a.c. They react to alternating sine-wave

More information

MEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers

MEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers MEDIUM VOLTAGE PRODUCT TJC 4 Indoor voltage transformers 2 TJC 4 INDOOR VOLTAGE TRANSFORMERS Parameters Highest voltage for equipment Power frequency test voltage, 1 min. Lightning impulse test voltage

More information

Fuse switch-disconnectors

Fuse switch-disconnectors Fuse switch-disconnector FH000 is intended for fuse-links with blade contacts size 000. It enables safe disconnection not only of rated current, but also overcurrent up to octuple rated current. A version

More information

MM: Bild angeben Content 690 V AC for baseplate, busbar and supporting rail mounting 60 Accessories 62 Technical Data see page 65 NU System The EFEN s

MM: Bild angeben Content 690 V AC for baseplate, busbar and supporting rail mounting 60 Accessories 62 Technical Data see page 65 NU System The EFEN s Basic Efficiency up to 1500 V 1-pole 3-pole SILAS MM: Bild angeben Content 690 V AC for baseplate, busbar and supporting rail mounting 60 Accessories 62 Technical Data see page 65 NU System The EFEN successfully

More information

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data B6, B7, BC6, BC7, TBC7 - and 4-pole mini contactors VB6, VB7, VBC6, VBC7 - and 4-pole mini reversing contactors Main pole Utilization characteristics according to IEC Standards IEC/EN 60947-1, IEC/EN 60947-4-1

More information

RESIDUAL CURRENT CIRCUIT BREAKERS OFI (10 ka)

RESIDUAL CURRENT CIRCUIT BREAKERS OFI (10 ka) Residual current circuit breakers RESIDUAL CURRENT CIRCUIT BREAKERS OFI (10 ka) They react to both alternating sine-wave residual current and pulsating direct current (type A) For protection: against accidental

More information

Control switch/load disconnect switch Series 8008

Control switch/load disconnect switch Series 8008 > s Control switch with 2, 3 or 4 pole Load switch 3 pole + 1 auxiliary contact > Rated operational voltage up to 690 V AC > Positive opening contacts > Contacts suitable for EM-STOP > Isolating characteristics

More information

FUSE BASES NH FUSE BASES 690V 160A 160A

FUSE BASES NH FUSE BASES 690V 160A 160A fuse bases NH NH 14 690V NH 16 ACCESSORIES FOR NH 18 CR 690V NH 20 SECTIONABLE NEUTRAL NH BASES 21 BS FUSE SWITCH DISCONNECTORS 690V NH NH Fuse bases for NH fuse links. For mounting on DIN/EN rail or

More information

Range 16A to 63A. Sensitivity 30mA, 100mA, 300mA, 500mA. Execution Double Pole, Four Pole. Specification IEC / IS : 2000

Range 16A to 63A. Sensitivity 30mA, 100mA, 300mA, 500mA. Execution Double Pole, Four Pole. Specification IEC / IS : 2000 The flow of current through electrical facilities always involves risks. Poorly insulated equipment, faulty wires and incorrect use of an electrical devise cause currents to flow through the wrong path

More information

NXPLUS C Single busbar. Maintenance-free for lifetime

NXPLUS C Single busbar. Maintenance-free for lifetime NXPLUS C Single busbar Maintenance-free for lifetime Energy Distribution Welcome! Page 2 Content Overview Technical data Typicals Panel design Circuit-Breaker panel Busbar Operation Metering Low-voltage

More information

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT 44LK-500/E.04/002A/A4 PROJECT NO 44LK-500 CHKD. BY VDV VDV A CLIMATIC CONDITIONS THIS DATA SHEET IS APPLICABLE FOR IN UTILITY BOILER PACKAGE DESIGN AMBIENT TEMPERATURE 45 C 2 ALTITUDE ( ABOVE MSL ) 6.7

More information

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left 87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 DX³ RCBO 4500/6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection...

More information

Varius SUMMARY OF MODELS

Varius SUMMARY OF MODELS SUMMARY OF MODELS FH000 FH00 FH FH2 FH LTL4a Rated operating current I e 60 A 60 A 250 A 400 A 60 A 600 A Rated operating voltage AC/DC U e 690 V 690 V 690 V 690 V 690 V 690 V Size 000 00 2 4a Fuse-link

More information

8WH2 Spring-Loaded Terminals

8WH2 Spring-Loaded Terminals 8WH2 Spring-Loaded Terminals /2 Introduction /3 General data on 8WH /7 8WH through-type terminals 1) /18 8WH hybrid through-type terminals 1) /21 8WH fuse terminals /23 8WH isolating blade terminals /25

More information

Outdoor load disconnectors DRIBO Flc GB. three-pole design rated voltage 25 and 38.5 kv rated current 630 A

Outdoor load disconnectors DRIBO Flc GB. three-pole design rated voltage 25 and 38.5 kv rated current 630 A Outdoor load disconnectors three-pole design rated voltage 25 and 38.5 kv rated current 630 A outdoor load disconnectors The breaking operation at the load disconnectors uses the energy of spring-based

More information

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable Medium-Voltage Switchgear Totally Integrated Power SIMOSEC Catalog HA 41.43 Edition Sept. 2014 Answers for infrastructure and cities. Neue

More information

Change-over Disconnectors HUVS Range 36kV (630 to 6300Amp)

Change-over Disconnectors HUVS Range 36kV (630 to 6300Amp) Changeover switches 7.2kV to 40.5kV For more than 100 years, Mersen has been providing the market with safe, reliable and longer life time off-load disconnectors. These devices offer high performances

More information

Perfection that Matters

Perfection that Matters Perfection that Matters Switchgear Range Catalogue 2017 Contents Power Series Distribution Boards Classique Distribution Boards Miniature Circuit Breaker Isolator Residual Current Circuit Breaker Residual

More information

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3 Introducing the New WEG Series. The was developed according to IEC 60947-3 & UL508. The compact, reliable design of the allows the operator to safely disconnect power and isolate the circuit within the

More information

Intertek Level 4 RTL (ASTA Recognized Laboratory Scheme)

Intertek Level 4 RTL (ASTA Recognized Laboratory Scheme) Page 1 of 6 Site(s) applicable to the recognition: Central Power Research Institute Prof Sir C.V. Raman Road P.B. No. 8066 Sadashivanagar Sub-P.O. Bangalore 560 080 India Central Power Research Institute

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS STANDARD METAL CLAD INDOOR VCB TECHNICAL DATA Rated Voltage (Ur) in kv 12 Rated Normal Current (Ir) in Ampere 630/1250 Rated Frequency (fr) in Hz 50 Rated Insulation level (1 min)

More information

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX IEC-Contactor RSC 1 Features Rated operational current 9 63 (C-3) Coil voltages C 24, 230V 3 main contacts and auxiliary contact Extendable with auxiliary contact block Mounting position any 2 Description

More information

Residual current devices

Residual current devices Residual devices FH00 Plus of range /30 Technical features table /3 Ordering information /34 Technical details /37 DS01 and DS0C Plus of range /38 Technical features table /40 Ordering information DS01

More information

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors MOTOR STARTERS SM Basic function Switching and protection of motors up to A Protection against short-circuit and protection against overload The device responds to phase failure The device is provided

More information

W DATA SHEET: COMBINED RCD/MCB DEVICES BO, 3-POLE

W DATA SHEET: COMBINED RCD/MCB DEVICES BO, 3-POLE W DATA SHEET: COMBINED RCD/MCB DEVICES BO, 3-POLE W SCHRACK-INFO Combined RCD/MCB device Type-A: Protects against special forms of residual pulsating DC which have not been smoothed Line voltage-independent

More information

15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250

More information

34-SDMS-01 SPECIFICATIONS FOR

34-SDMS-01 SPECIFICATIONS FOR SPECIFICATIONS FOR M V DROPOUT FUSE CUT OUTS This specification is property of SEC and subject to change or modification without any notice CONTENTS C l a u s e s: Page No. 1- SCOPE 3 2- CROSS REFERENCES

More information

Varius SUMMARY OF MODELS

Varius SUMMARY OF MODELS Varius SUMMARY OF MODELS Type FH00 FH1 FH2 FH3 LTL4a Rated operating current I e 160 A 160 A 250 A 400 A 630 A 1 600 A Rated operating voltage AC/DC U e 690 V 690 V 690 V 690 V 690 V 690 V Size 000 00

More information

70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX

70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX 70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX SWITCH DISCONNECTORS IN METAL BOX ATEX SWITCH DISCONNECTORS IN METAL BOX The switch disconnectors in plastic boxes, which are available in control or emergency

More information

ic60h (6kA) single module combined RCD/MCB units ic60h (10kA) single module combined RCD/MCB units ild residual current circuit breakers idpn N Vigi

ic60h (6kA) single module combined RCD/MCB units ic60h (10kA) single module combined RCD/MCB units ild residual current circuit breakers idpn N Vigi Contents Miniature circuit breakers ic60n miniature circuit breakers 6kA, C curve, 6-63A ic60h miniature circuit breakers 10kA, C curve, 6-63A ic60n miniature circuit breakers 6kA, B curve, 6-63A ic60h

More information

About us. Switchgear Factory, Mumbai

About us. Switchgear Factory, Mumbai About us Larsen & Toubro is a technologydriven USD 8.5 billion company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field of Engineering, Construction,

More information

Technical Specification of 11KV 200Amp. (3-Pole/2-Pole) Air Break Switch Scope Description of the materials Standards Insulator make

Technical Specification of 11KV 200Amp. (3-Pole/2-Pole) Air Break Switch Scope Description of the materials Standards Insulator make Technical Specification of 11KV 200Amp. (3-Pole/2-Pole) Air Break Switch 1. Scope:- This specification covers manufacturing, testing and supply of 11KV 200Amp. 50Hz Air Break switches for outdoor installation

More information

new NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price

new NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price gg fuselinks 500V (IEC60269 - VDE0636 - DIN43620) with fuse blown indication NH Fuse links gg class with high

More information

Just the right switch for your application

Just the right switch for your application Series 7 Motor Disconnect Switches up to 100A U508 approved device suitable as motor disconnect TIP! Sprecher + Schuh s 7 line incorporates the latest modular design techniques to provide maximum functionality

More information

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België Control Equipment 01616E00 Position switches are used to monitor the position of moving parts of machines and plant. Can be used in safety circuits, as the device satisfies EN 60 947-5-1/DIN VDE 0660 part

More information

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1.5 nominal torque 0.2 W 4 VA Auxiliary switch

Technical data. Safety notes. Power consumption In operation At rest For wire sizing. 1.5 nominal torque 0.2 W 4 VA Auxiliary switch echnical data sheet Damper actuator NM4A-S-P Damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations For air control dampers up

More information

WESTERN ELECTRICITY SUPPLY COMPANY OF ORISSA, WESCO. GUARANTEED TECHNICAL PARTICULARS 1 of 2

WESTERN ELECTRICITY SUPPLY COMPANY OF ORISSA, WESCO. GUARANTEED TECHNICAL PARTICULARS 1 of 2 Sl. No. WESTERN ELECTRICITY SUPPLY COMPANY OF ORISSA, WESCO GUARANTEED TECHNICAL PARTICULARS 1 of 2 REQUIREMENTS 11 Kv, 200 Amps, A.B Switches. Particulars 1 Maker's name and Country of origin. 2 Type

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

Essential Loads also use stand by generator systems mostly in process industries as they relate to high restarting times or high down times.

Essential Loads also use stand by generator systems mostly in process industries as they relate to high restarting times or high down times. The need for continuous power supply and its reliability has increased rapidly over the years, especially in all those areas where uninterrupted power supply is a must. Modern systems are power dependent.

More information

DX³ RCBO 6000 A Phase + Neutral, neutral right side

DX³ RCBO 6000 A Phase + Neutral, neutral right side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX³ RCBO 6000 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation Connection... 1

More information

HIGH VOLTAGE SURGE ARRESTER SPECIFICATION

HIGH VOLTAGE SURGE ARRESTER SPECIFICATION HIGH VOLTAGE SURGE ARRESTER SPECIFICATION Applications: (Polymer housed MOA for 110kv) (The polymer housed MOA for 10kv) (Porcelain housed MOA for 220kv) (35kv MOA without gaps for middle phase) (110kv

More information

Indoor switches for railway lines. single-pole design rated voltage up to 27,5 kv rated current up to 4000 A

Indoor switches for railway lines. single-pole design rated voltage up to 27,5 kv rated current up to 4000 A Indoor switches for railway lines single-pole design rated voltage up to 27,5 kv rated current up to 4000 A General These Driescher indoor switching devices are specifically designed for railway applications.

More information

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE Switch disconnectors A modular and flexible range Contact gap 7 mm (norm 5.5 mm) Reversible terminal feature ÿ IN ENCLOSURE - Degree of protection: up to IP 66 - For 25A to 100A size switches (see Ithe

More information