1 fuse bases NH

2

3 NH V NH 16 ACCESSORIES FOR NH 18 CR 690V NH 20 SECTIONABLE NEUTRAL NH BASES 21 BS FUSE SWITCH DISCONNECTORS

4 690V NH NH Fuse bases for NH fuse links. For mounting on DIN/EN rail or with screw fixing. Single-phase or three-pole type. Connection by screws, fixed nut or clamps. Wide range of accessories (contact covers, fuse link covers, partition walls) that enables IP20 protection index. Multi-pole units can be made with connection accessories. NH fuse bases are made of self-extinguishable materials and have silver plated copper contacts. There are two contact styles, one of them with double spring in order to obtain an optimum operation. Manufactured according IEC, EN and DIN standards A THREE DESCRIPTION REFERENCE U PACKING (V AC) Uni./BOX SCREW FIXING SCREW CONNECTION /54 CLAMP CONNECTION /54 CLAMP-SCREW CONNECTION FIXED SCREW CONNECTION /54 RAIL + SCREW FIXING SCREW CONNECTION /54 CLAMP CONNECTION CLAMP-SCREW CONNECTION FIXED SCREW CONNECTION /54 RAIL + SCREW FIXING SCREW CONNECTION /20 CLAMP CONNECTION /20 CLAMP-SCREW CONNECTION /20 FIXED NUT CONNECTION /20 RAIL + SCREW FIXING WITH TERMINAL COVERS SCREW CONNECTION CLAMP CONNECTION CLAMP-SCREW CONNECTION FIXED NUT CONNECTION RAIL + SCREW FIXING IP20 PROTECTION SCREW CONNECTION CLAMP CONNECTION CLAMP-SCREW CONNECTION FIXED NUT CONNECTION A SCREW FIXING - SCREW CONNECTION RAIL + SCREW FIXING - SCREW CONNECTION THREE SCREW FIXING - SCREW CONNECTION RAIL + SCREW FIXING - SCREW CONNECTION ANDARDS APPROVALS TECHNICAL TECHNICAL TECHNICAL COMPATIBLE COMPATIBLE COMPATIBLE IEC TECHNICAL DATA ACCESSORIES ASSEMBLY DIMENSIONS gg 500V gg 690V am 500V & 690V SYEM NH FUSE LINKS NH FUSE LINKS NH FUSE LINKS IEC D I R E C T I V E 2002/95/EC EN EN DIN

5 690V NH NH 250A DESCRIPTION REFERENCE U PACKING (V AC) SCREW FIXING - SCREW CONNECTION RAIL + SCREW FIXING - SCREW CONNECTION THREE SCREW FIXING - SCREW CONNECTION RAIL + SCREW FIXING - SCREW CONNECTION A SCREW FIXING SCREW CONNECTION FIXED NUT CONNECTION RAIL + SCREW FIXING - SCREW CONNECTION THREE SCREW FIXING - SCREW CONNECTION RAIL DIN FIXING - SCREW CONNECTION A SCREW FIXING - SCREW CONNECTION RAIL + SCREW FIXING - SCREW CONNECTION THREE SCREW FIXING - SCREW CONNECTION RAIL + SCREW FIXING - SCREW CONNECTION NH4 1000A 1250A 2500A SCREW FIXING - SCREW CONNECTION SCREW FIXING SCREW FIXING SCREW CONNECTION SCREWS M10 CONNECTION SCREWS M10 CONNECTION W/MIC NH FUSE BASE 2500A GROUP NH FUSE BASE 2500A GROUP W/MIC

6 690V NH WITH MICROSWITCH NH Fuse bases for NH fuse links with striker. For mounting on DIN/EN rail or screw fixing. Connection by screws. NH fuse bases are made with self-extinguishable materials and have silver plated copper contacts with double spring in order to obtain optimum operation. Manufactured according IEC, EN and DIN standards A 250A 400A 630A DESCRIPTION REFERENCE U PACKING (V) RAIL + SCREW FIXING - SCREW CONNECTION RAIL + SCREW FIXING - SCREW CONNECTION RAIL + SCREW FIXING - SCREW CONNECTION RAIL + SCREW FIXING - SCREW CONNECTION NH4 1000A 1250A SCREW FIXING SCREW CONNECTION SCREW CONNECTION NH4 NH ACCESSORIES PARTITION WALLS SIZE In REFERENCE DESCRIPTION PACKING (A) SNAP-ON FIXING SNAP-ON FIXING 2-250/ SNAP-ON FIXING SNAP-ON FIXING 2 NH SCREW FIXING 1 NH ACCESSORIES SEPARATORS SIZE REFERENCE PACKING ANDARDS APPROVALS TECHNICAL TECHNICAL TECHNICAL COMPATIBLE COMPATIBLE COMPATIBLE IEC TECHNICAL DATA ACCESSORIES ASSEMBLY DIMENSIONS am 500V & 690V SYEM WITH RIKER IEC D I R E C T I V E 2002/95/EC NH FUSE LINKS EN EN DIN gg 500V WITH RIKER NH FUSE LINKS 08 gg 690V WITH RIKER NH FUSE LINKS 10

7 NH NH ACCESSORIES TERMINAL COVERS SIZE REFERENCE DESCRIPTION PACKING THREE INTEGRAL PARTITION WALLS INCORPORATED NH ACCESSORIES FUSE LINKS COVERS SIZE REFERENCE PACKING NHC1 NHC2 NHC3 NH ACCESSORIES IP20 PROTECTION KITS SIZE REFERENCE PACKING THREE THREE THREE THREE THREE NH ACCESSORIES MICROSWITCHES SIZE REFERENCE DESCRIPTION PACKING A-250V PRESENCE - FUSION A-250V PRESENCE - FUSION A-250V PRESENCE - FUSION A-250V PRESENCE - FUSION 1 NH ACCESSORIES MICROSWITCHES FOR NH LINKS REFERENCE DESCRIPTION PACKING Uni./BOX /00/0/C1/1/C2/2/C3/3 1/

8 CR 690V NH NH Fuse bases for NH fuse links. For screw fixing. Single-phase or three-pole type. Connection by screws. NH CR fuse bases are made of ceramics and have silver plated copper contacts. There are two contact styles, one of them with double spring in order to obtain an optimum operation. Manufactured according IEC, EN and DIN standards. DESCRIPTION REFERENCE U PACKING (V) Uni./BOX SCREW CONNECTION /72 THREE SCREW CONNECTION / SCREW CONNECTION THREE SCREW CONNECTION SCREW CONNECTION THREE SCREW CONNECTION SCREW CONNECTION THREE SCREW CONNECTION ANDARDS APPROVALS TECHNICAL TECHNICAL COMPATIBLE COMPATIBLE COMPATIBLE IEC TECHNICAL DATA DIMENSIONS gg 500V gg 690V am 500V & 690V NH FUSE LINKS NH FUSE LINKS NH FUSE LINKS IEC D I R E C T I V E 2002/95/EC EN EN DIN

9 CR NH NH ACCESSORIES PARTITION WALLS SIZE In REFERENCE PACKING SNAP-ON FIXING (A) SCREW FIXING / / CR NH4 CR NH4 NH ACCESSORIES NEUTRAL LINKS SIZE In REFERENCE PACKING (A) Uni./BOX / NH NH ACCESSORIES REPLACEMENT HANDLE SIZE In REFERENCE PACKING (A) CR NH4 NH ACCESSORIES TERMINALS 1 CABLE 2 CABLES SIZE CROSS SECTION REFERENCE PACKING min... MAX (mm 2 ) TECHNICAL TERMINALS DIMENSIONS

10 NH SECTIONABLE NEUTRAL NH Neutral bases for mounting on DIN/EN rail or with screw fixing. Connection by screws or clamps. and can be mounted in NH fuse bases with connection accessories. Made of self-extinguishable materials and have silver plated copper contacts. In REFERENCE U S PACKING (A) (V) Uni./BOX CONNECTION SCREW - SCREW / / CONNECTION CLAMP - SCREW / / CONNECTION CLAMP - CLAMP / / ANDARDS APPROVALS TECHNICAL IEC IEC EN D I R E C T I V E 2002/95/EC DIMENSIONS EN DIN

11 BS 690V NH THREE NH FUSE SWITCH DISCONNECTORS Three-phase fuse switch disconnectors for NH fuse-links. Available from size 000 to size 3 for board fixing and a mode size 00 for mounting on 60 mm busbar system. They provide IP20 protection against contacts and are manufactured in self-extinguishable materials. DESCRIPTION REFERENCE U PACKING (V) 0 100A FUSE SWITCH DISCONNECTOR DIRECT CONNECTION A FUSE SWITCH DISCONNECTOR M8 SCREW CONNECTION FUSE SWITCH DISCONNECTOR Cu4-70mm 2 CLAMP CONNECTION A FUSE SWITCH DISCONNECTOR 60mm BUSBAR CONNECTION (Clamp or Screw for output connection) A FUSE SWITCH DISCONNECTOR M10 SCREW CONNECTION A FUSE SWITCH DISCONNECTOR M10 SCREW CONNECTION A FUSE SWITCH DISCONNECTOR M12 SCREW CONNECTION ANDARDS IEC IEC EN EN DIN APPROVALS D I R E C T I V E 2002/95/EC TECHNICAL DIMENSIONS 44 TECHNICAL TECHNICAL DATA 44

12 NH NH NH4 CR CR CR CR CR BODY POLYAMIDE +25% F.V. UL94-V0 POLYAMIDE +25% F.V. UL94-V0 POLYAMIDE +25% F.V. UL94-V0 POLYAMIDE +25% F.V. UL94-V0 POLYAMIDE +25% F.V. UL94-V0 UP THERMOSSETING EEATITE CER-221 EEATITE CER-221 EEATITE CER-221 EEATITE CER-221 EEATITE CER-221 CONTACTS SCREW, NUT AND WASHERS EEL QUALITY 8.8 EEL QUALITY 8.8 EEL QUALITY 8.8 EEL QUALITY 8.8 EEL QUALITY 8.8 EEL QUALITY 8.8 EEL QUALITY 8.8 EEL QUALITY 8.8 EEL QUALITY 8.8 EEL QUALITY 8.8 EEL QUALITY C DERATING TEMPERATURE 30 C 0,95 0,95 0,95 0,95 0,95 0,95 0,95 0,95 0,95 0,95 0,95 40 C 0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9 50 C 0,8 0,8 0,8 0,8 0,8 0,8 0,8 0,8 0,8 0,8 0,8 MAX. POWER DISIPATION 12 W 25 W 32 W 45 W 60 W 90 W 12 W 25 W 32 W 45 W 60 W DEGREE OF PROTECTION IP00/IP20 IP00/IP20 IP00/IP20 IP00/IP20 IP00/IP20 IP00 IP00 IP00 IP00 IP00 IP00 SCREW M8 M8 CONNECTING M8 M10 M12 M12 M16 M8 M10 M12 M12 CLAMP 2 x M6 2 x M6 SCREW 10 Nm MAX. TIGHTENING TORQUE 10 Nm 32 Nm 32 Nm 32 Nm 56 Nm 10 Nm 10 Nm 32 Nm 32 Nm 32 Nm CLAMP 4 Nm FIXING WITH MICROSWITCH 16A - 250V RAIL DIN SCREW PRESENCE- FUSION FUNCTION TEMPERATURE C C C C C C C C C C C ORAGE TEMPERATURE C C C C C C C C C C C

13 TECHNICAL NH NH ACCESSORIES ASSEMBLY SYEM z x c v b z TERMINAL COVERS x BODY c SEPARATOR v PARTITION WALL b FUSE LINKS COVER TECHNICAL - THREE NH DIMENSIONS SCREW FIXING RAIL 35x7,5 mm ACC. TO ANDARD EN * IP20 VERSION

14 NH TECHNICAL - THREE NH DIMENSIONS SIZE A B C D E F G H I J K L M N O P Q ,5 91,5 185 M8 25 7, , M ,5 20, M ,5 20, M ,5 20,5 TECHNICAL NH4 NH DIMENSIONS 2 SCREWS VERSION 2500 A VERSION * 2500 A VERSION: 63 mm

15 NH TECHNICAL NH4 WITH MICROSWITCH NH DIMENSIONS SIZE A B C , NH

16 NH TECHNICAL SECTIONABLE NEUTRAL DIMENSIONS SIZE A B C D E F G H I J K L 120,5 7, M , M , M

17 TECHNICAL CR CLIP CONTACT NH - THREE NH DIMENSIONS SIZE A B C D E F G H I J K L M N O P Q 120, , , M8 25 7, , M8 25 7, , M ,5 20, M ,5 20, M ,5 20,5

18 NH TECHNICAL CR NH4 NH ACCESSORIES - TERMINALS DIMENSIONS REFERENCE A B C D E F M5 M M6 M M8 M M10 M M5 M M6 M M8 M M10 M12

19 TECHNICAL BS 0 NH THREE NH FUSE SWITCH DISCONNECTORS DIMENSIONS & TECHNICAL DATA * 202 mm WITH TERMINAL COVERS SIZE A B C * (BUSBAR CONNECTION) * SIZE 0 Rated current (I th ) 100 A 160 A 250 A 400 A 630 A Rated operational voltage (U e) 690 V 690 V 690 V 690 V 690 V Rated frequency Hz Hz Hz Hz Hz Maximum power dissipation of fuse link (P n ) 7,5 W 12 W 23 W 34 W 48 W Rated insulation voltage (U i ) 690 V 1000 V 1000 V 1000 V 1000 V Rated impulse withstand voltage (U imp ) 6 kv 8 kv 12 kv 12 kv 12 kv Pollution degree Protection degree IP20 IP30 IP20 IP20 IP20 Utilization categories AC22B 400V 100A AC21B 690V 100A DC21B 440V 100A Connection DIRECT 1-50 mm 2 Short-circuit resistance with fuse-links > 80 ka AC23B 400V 160A AC22B 500V 160A AC21B 690V 125A DC22B 440V 160A M8 SCREWS 4-70 mm 2 CLAMPS 60 mm BUSBAR + 3 M8 Screws or mm2 Clamps > 80 ka 500V > 50 ka 690V AC23B 400V 250A AC22B 500V 250A AC21B 690V 200A DC22B 220V 250A AC23B 400V 400A AC22B 500V 400A AC21B 690V 315A DC21B 440V 400A AC23B 400V 630A AC22B 500V 630A AC21B 690V 500A M10 SCREWS M10 SCREWS M12 SCREWS > 80 ka 500V > 50 ka 690V > 80 ka > 80 ka 500V > 50 ka 690V

20 THE PROTECTION FORMULA ELECTRONIC CYLINDRICAL PHOTOVOLTAIC RAPIDPLUS NH SPECIAL FUSE LINKS DOMEIC D & DO TRANSFORMERS experts in PROTECTION

21 HEAD OFFICE & FACTORY SILICI, CORNELLA DE LLOBREGAT BARCELONA SPAIN Tel Fax EXPORT SALES Tel Fax NATIONAL SALES ED Tel Fax

fuse-links & fuse holders PHOTOVOLTAIC

fuse-links & fuse holders PHOTOVOLTAIC fuse-links & fuse holders 04 gpv FOR APPLICATIONS 04 gpv FOR APPLICATIONS 05 gpv & FOR APPLICATIONS 06 PMF FUSE HOLDERS FOR APPLICATIONS 07 ST & FUSE BASES FOR APPLICATIONS FUSE HOLDERS & BASES gpv 10x38

More information

FUSE-LINKS FOR PHOTOVOLTAIC APPLICATIONS

FUSE-LINKS FOR PHOTOVOLTAIC APPLICATIONS 1 2 06 PML 10/14x85 1500V FUSE HOLDERS 08 CLIP CONTACT FOR φ10 FUSE LINKS 05 PMX & 14x51 FUSE HOLDERS 02 gpv & 14x51 600 &/1100 FUSE LINKS 03 gpv 1200 & 1500V FUSE LINKS 04 gpv NH1, NH2 & NH3 FUSE LINKS

More information

CYLINDRICAL FUSES. 8x32. 10x38. 14x51. In REFERENCE U BREAKING CAPACITY REFERENCE U BREAKING CAPACITY PACKING (A) IEC /95/EC

CYLINDRICAL FUSES. 8x32. 10x38. 14x51. In REFERENCE U BREAKING CAPACITY REFERENCE U BREAKING CAPACITY PACKING (A) IEC /95/EC fuses 02 gg 04 am gg Cylindrical fuse links gg class for use as general protection against overloads and short circuits, intended as protection of cables, power lines and equipment. Made of ceramic tube

More information

RAPIDPLUS. high speed fuse links for semiconductors

RAPIDPLUS. high speed fuse links for semiconductors high speed fuse links for semiconductors RAPIDPLUS 2 PAGE04 ar PAGE05 gr PAGE06 gs NH ar RAPIDPLUS ar fuse links are intended to clearing short-circuits and have been designed and manufactured to have

More information

fuses fuse holders CYLINDRICAL

fuses fuse holders CYLINDRICAL fuses fuse holders 02 gg FUSES 04 am FUSES FUSES 09 PMC COMPACT 09 -CC FOR CC CLASS FUSE-LINKS 11 PMB PLUG CONNECTION 11 CLIP CONTACT FOR φ10 FUSE-LINKS 10 PMF 11 BAC OPEN FUSE BASES 06 gg FUSES FUSES

More information

RAPIDPLUS. high speed fuse links for semiconductors

RAPIDPLUS. high speed fuse links for semiconductors high speed fuse links for semiconductors RAPIDPLUS 2 PAGE04 ar HIGH SPEED FUSE LINKS FOR SEMICONDUCTORS PAGE05 gr HIGH SPEED FUSE LINKS FOR SEMICONDUCTORS PAGE06 gs NH HIGH SPEED FUSE LINKS FOR SEMICONDUCTORS

More information

fuse holders CYLINDRICAL1

fuse holders CYLINDRICAL1 fuse holders CYLINDRICAL1 2 6 PMF MODULAR 7 MODULAR 9 PMC COMPACT 9 PMCC COMPACT 1 SC SCREW FIXING 1 BAC OPEN 11 PMP PANEL MOUNTING 11 PMB SOCKET PMF MODULAR Modular fuse holders for industrial cylindrical

More information

CYLINDRICAL. fuse holders

CYLINDRICAL. fuse holders fuse holders CYLINDRICAL 04 07 PMC MODULAR FUSE COMPACT HOLDERS 07 -CC FOR CC CLASS FUSE-LINKS 08 PMF 09 SC SCREW FIXING 10 PMB PLUG CONNECTION 10 CLIP CONTACT FOR φ10 FUSE-LINKS 09 BAC OPEN FUSE BASES

More information

CYLINDRICAL FUSES CYLINDRICAL FUSES

CYLINDRICAL FUSES CYLINDRICAL FUSES fuses 1 2 02 04 Cylindrical fuse links class for use as general protection against overloads and short circuits, intended as protection of cables, power lines and equipment. Made of ceramic tube with high

More information

INDUSTRIAL CYLINDRICAL FUSE LINKS

INDUSTRIAL CYLINDRICAL FUSE LINKS gg Cylindrical gg class for use as general protection against overloads and short circuits, intended as protection of cables, power lines and equipment. Made of ceramic tube with high withstand to internal

More information

fuse holders & bases

fuse holders & bases PMF Modular fuse holders for industrial cylindrical fuse links. For mounting on DIN/EN rail. Single phase models, single-phase+neutral in only one module and multi-pole types. Available with fusing indicator

More information

Special Purpose Fuses

Special Purpose Fuses Special Purpose Fuses Fuses for DC voltage applications www.eti.si ETI Elektroelement d.d. Obrezija 5, SI - 111 Izlake Slovenija Tel. + 38 03 5 57 570 Faks + 38 03 5 7 077 eti@eti.si NH DC 80 V - Telecom

More information

new NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price

new NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price gg fuselinks 500V (IEC60269 - VDE0636 - DIN43620) with fuse blown indication NH Fuse links gg class with high

More information

Cylindrical fuse-link

Cylindrical fuse-link Cylindrical fuse-link Technical data Rated voltage Rated current Rated frequency Rated breaking capacity Characteristics ody material 00 V AC, 00 V AC, 90 V AC CH 8 - A/00 V CH 0,- A/00 V, 0-3 A/00 V CH

More information

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole MULTIBLOC 2.RST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC 2.RST8 comprises NH fuse switch disconnectors for 400A. Products are designed in triple

More information

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole MULTIBLOC 3.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 3.ST8 comprises NH fuse switch disconnectors for 630A. They are designed for bottom

More information

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole MULTIBLOC 1.RST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC 1.RST8 comprises NH fuse switch disconnectors for 250A. Products are designed in triple

More information

Horizontal fuse disconnects

Horizontal fuse disconnects THE NAME FOR SAFETY Horizontal fuse disconnects Horizontal fuse disconnects Horizontal fuse Disconnects are used in building installations, switchgear and controlgear as well as in power utility networks.

More information

MULTIBLOC 000.ST8 Size 000, 100A, 690VAC, Design for Bottom Fitting, Triple Pole

MULTIBLOC 000.ST8 Size 000, 100A, 690VAC, Design for Bottom Fitting, Triple Pole MULTIBLOC 000.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR FEATURES & BENEFITS The production programme of MULTIBLOC 000.ST8 comprises NH fuse switch disconnectors for 100A. They are designed

More information

MULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole

MULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole MULTIBLOC 1.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 1.ST8 comprises NH fuse switch disconnectors for 250A. They are designed for bottom

More information

Cylindrical fuse-link

Cylindrical fuse-link ylindrical fuse-link Technical data Rated voltage Rated current Rated frequency Rated breaking capacity haracteristics Body material 00 V A, 500 V A, 90 V A H 8-5 A/00 V H 0,5- A/500 V, 0-3 A/00 V H -5

More information

Fuse switch disconnectors

Fuse switch disconnectors SWITCHGEAR RBK Fuse switch disconnectors intended for distribution of electricity and protection of electrical equipment against short-circuits and overloads, with industrial fuse links ENERGY SAFELY SWITCHED

More information

Fuse switch disconnectors

Fuse switch disconnectors SWITCHGEAR 62 RBK pro Fuse switch disconnectors designed for distribution of electricity and protection of electrical equipment against short-circuits and overloads with industrial fuse links. ENERGY SAFELY

More information

MM: Bild angeben Content 690 V AC for baseplate, busbar and supporting rail mounting 60 Accessories 62 Technical Data see page 65 NU System The EFEN s

MM: Bild angeben Content 690 V AC for baseplate, busbar and supporting rail mounting 60 Accessories 62 Technical Data see page 65 NU System The EFEN s Basic Efficiency up to 1500 V 1-pole 3-pole SILAS MM: Bild angeben Content 690 V AC for baseplate, busbar and supporting rail mounting 60 Accessories 62 Technical Data see page 65 NU System The EFEN successfully

More information

MULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole

MULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole MULTIBLOC 2.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 2.ST8 comprises NH fuse switch disconnectors for 400A. They are designed for bottom

More information

MULTIVERT 1000A Main Incomer, 690VAC

MULTIVERT 1000A Main Incomer, 690VAC IEC FUSE SWITCH DISCONNECTORS NH VERTICAL FUSE SWITCH DISCONNECTOR FEATURES & BENEFITS MULTIVERT NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors. They are designed

More information

LINOCUR Size D02 63A 230VAC/440VAC

LINOCUR Size D02 63A 230VAC/440VAC IEC FUSE SWITCH DISCONNECTORS D0 FUSE COMBINATION UNITS The D0 Linocur is a combination of switch disconnector fuse and Neozed 63A fuse-link, equiped with significant safety characeristics and sophisticated

More information

Power distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly

Power distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly NH fuse-switch disconnectors, size 000 Version -pole, cable outlet at the top/bottom For the use of fuse inserts to EN 60 - Technical specifications to IEC/EN 60 947-, see chapter -5, page 6 see chapter

More information

IEC Low Voltage General Purpose Protection

IEC Low Voltage General Purpose Protection , 6A, 0/400VAC (/440VAC) Complying with DIN VDE 0660 Part 07 EN / IEC 60947- DIN VDE 066 Part IEC 6069- DIN VDE 068 DIN VDE 4880 The D0-LINOCUR is a combination of switch-disconnector-fuse and NEOZED 6

More information

Technical data. Busbar support 3 7, 5 6, 8 ETIBUSBAR 1 0, 5 BBS-60/4

Technical data. Busbar support 3 7, 5 6, 8 ETIBUSBAR 1 0, 5 BBS-60/4 Busbar support 20 30 BBS-/1 BBS-/3 57 52 29 29 1 5 3 0 1 5 10 2 0 5 3 7, 5 6 0 6 0 6 0 6, 8 12 1 0, 5 7 5 1 2 5 2 4 0 20 30 18 BBS-/4 563 98,5 10 29 93,5 5 29 18 75 180 10,5 6,8 30 30 25 20 52,5 12 BBS-/3-16

More information

W DATASHEET: MINIATURE CIRCUIT BREAKER (MCB), SERIES AMPARO

W DATASHEET: MINIATURE CIRCUIT BREAKER (MCB), SERIES AMPARO W DATASHEET: MINIATURE CIRCUIT BREAKER (MCB), SERIES AMPARO W SCHRACK-INFO Lift and clamp terminals on both sides Terminal guide for secure connection Terminal cross-section: 1-25mm² Snap-on mounting for

More information

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC. Page -2 Page -2 AC FUSE HOLDERS Version without indicator: 1P, 1P+N, 2P, 3P, 3P+N Version with indicator: 1P For fuses x38, 14x51 and 22x58mm IEC class gg or am. IEC rated current: 32A, 50A, 0A IEC rated

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

Limitor -G General Purpose Fuses

Limitor -G General Purpose Fuses Limitor -G General Purpose Fuses HIGH VOLTAGE IEC FUSES DIN HV GENERAL PURPOSE FUSES FOR TRANSFORMERS FEATURES & BENEFITS Mersen HV fuse-links have been used for reliable protection in high-voltage switchgear

More information

CATALOG. EasyLine XLP Fuse Switch Disconnector poles

CATALOG. EasyLine XLP Fuse Switch Disconnector poles CATALOG EasyLine XLP Fuse Switch Disconnector 1-2-3-4 poles 2 E A S Y L I N E X L P F U S E S W I TC H D I S C O N N E C TO R 1-2 - 3-4 P O L E S Contents 004 005 Introduction EasyLine XLP 006 007 Introduction

More information

NH LOW VOLTAGE a FUSE SYSTEM

NH LOW VOLTAGE a FUSE SYSTEM NH LOW VOLTAGE a FUSE SYSTEM NH DIN Low Voltage Fuse System from Cooper Bussmann High Breaking Capacity 400Vac, 500Vac and 690Vac Insulated Tag variants available Dual Indication VDE 066 Part 1 DIN 4 60

More information

Varius SUMMARY OF MODELS

Varius SUMMARY OF MODELS SUMMARY OF MODELS Type 10 14 22 OPT22/OPT20 OPVF10 Rated operating current I e / Rated current I n 32 A / - 63 A / - 125 A / - 63 A / - - / 30 A Rated operating voltage U e / Rated voltage U n AC 690 V

More information

Varius SUMMARY OF MODELS

Varius SUMMARY OF MODELS SUMMARY OF MODELS FH000 FH00 FH FH2 FH LTL4a Rated operating current I e 60 A 60 A 250 A 400 A 60 A 600 A Rated operating voltage AC/DC U e 690 V 690 V 690 V 690 V 690 V 690 V Size 000 00 2 4a Fuse-link

More information

Fuse switch-disconnectors

Fuse switch-disconnectors Fuse switch-disconnector FH00 is intended fuse-links with blade contacts size 000 and 00. It enables safe disconnection not only of rated current, but also overcurrent up to octuple rated current. A version

More information

Safety switches for hinges

Safety switches for hinges Safety switches for hinges Selection diagram ACTUATORS L L6 L9 L16 FR FM FX FZ FK CONTACT BLOCKS 6 7 9 14 18 snap action 1NO+1N, make before break, shifted, close 21 4 66 NC 2NO+ 1NO+ CONDUIT ENTRIES Threaded

More information

Fuse switch-disconnectors

Fuse switch-disconnectors Fuse switch-disconnector FH000 is intended for fuse-links with blade contacts size 000. It enables safe disconnection not only of rated current, but also overcurrent up to octuple rated current. A version

More information

Fuse Switch Disconnectors XNH. Fuse Switch Disconnectors XNH... For fuse links NH000 to NH3. Rated operating current of 160, 250, 400 and 630A

Fuse Switch Disconnectors XNH. Fuse Switch Disconnectors XNH... For fuse links NH000 to NH3. Rated operating current of 160, 250, 400 and 630A www.eaton.eu Panel Building Accessories PIFT Plug In Fused Terminal Fuse Disconnectors Thermostats Filters and Fans Terminals Electrical Cabinet Heating Catalogue 2016 Fuse Switch Disconnectors XNH Fuse

More information

PowerLine OS Switch Fuses A, 690V

PowerLine OS Switch Fuses A, 690V Technical Brochure PowerLine OS Switch Fuses 20...160 A, 690V Brochure OS 10 GB 99-04 9902CD04 ABB Control New Switch Fuse Range 2 3 Total user safety Total user safety Fuse carriers fully IP20 protected

More information

INNOZED D0 fuse-bases with touch protection

INNOZED D0 fuse-bases with touch protection INNOZED D0 fusebases with touch protection INNOZED D0 fusebases with touch protection FUSE HOLDERS, FUSE BASES AND SUPPORTS IEC D0 & D FUSE BASES FEATURES & BENEFITS INNOZED is a fuse base for D0 fuselinks,

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A fuser_548_a_1_cat fuser_532_a_1_cat fuser_539_a_1_cat FUSERBLOC from 25 to 32 A FUSERBLOC from 630 to 1250 A FUSERBLOC from 32 to 400 A Function FUSERBLOC are manually operated multipolar fuse combination

More information

Modulostar CMS10 Modular fuse-holders

Modulostar CMS10 Modular fuse-holders Modulostar CMS10 FUSE HOLDERS, FUSE BASES AND SUPPORTS IEC CYLINDRICAL FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive Modulostar range of Mersen fuse-holders. are finger-safe under IEC

More information

Fuse Switch Disconnectors XNH. Fuse Switch Disconnectors XNH... For fuse links NH000 to NH3. Rated operating current of 160, 250, 400 and 630A

Fuse Switch Disconnectors XNH. Fuse Switch Disconnectors XNH... For fuse links NH000 to NH3. Rated operating current of 160, 250, 400 and 630A www.eaton.eu Panel Building Accessories PIFT Plug In Fused Terminal Fuse Disconnectors Filters and Fans Fuse Switch Disconnectors XNH Thermostats Terminals Catalogue 2017 Electrical Cabinet Heating Fuse

More information

Fuse holders and fuses

Fuse holders and fuses Modular size for 10x38, 14x51 and 22x58mm fuses Finger safe - IEC IP20 degree of protection against accidental contact with live parts and with sealable cover for operators safety Version with status indicator

More information

Vertical fuse disconnects

Vertical fuse disconnects Vertical fuse disconnects Vertical fuse disconnects Vertical fuse disconnects are designed to receive NH fuse links. Hinged fuse-carriers enable opening and closing operation in electric circuits under

More information

3NP1 Fuse Switch Disconnectors up to 630 A

3NP1 Fuse Switch Disconnectors up to 630 A Switch Disconnectors 3NP1 Fuse Switch Disconnectors up to 630 A Introduction Overview All key product features at a glance available for all sizes Connection of circular conductors and laminated conductors

More information

UltraSafe US22 Modular fuse-holders

UltraSafe US22 Modular fuse-holders UltraSafe US22 FUSE HOLDERS, FUSE BASES AND SUPPORTS UL/CSA FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive UltraSafe range of Mersen fuse-holders. are finger-safe under IEC standards

More information

Low voltage NH knife-blade fuse-links

Low voltage NH knife-blade fuse-links Low voltage NH knife-blade fuse-links NV KOMBI advantages ETI is introducing a new generation of low-voltage fuse-links from size NV00C up to NV3 with new, dual indication of fuse-link operation, called

More information

LV HRC fuse switch-disconnectors

LV HRC fuse switch-disconnectors The 9 series LV HRC fuse switch-disconnectors of the DIN sizes 00-4a are suitable for surface mounting on mounting plates and for direct mounting on busbars. The different sizes are available as 1-pole,

More information

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489 Data Sheet System pro M compact for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU200 M is BB s solution for UL 489 branch circuit protection

More information

Vertical fuse disconnects

Vertical fuse disconnects THE NAME FOR SAFETY Vertical fuse disconnects Vertical fuse disconnects Vertical fuse disconnects are designed to receive NH fuse links. Hinged fuse-carriers enable opening and closing operation in electric

More information

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage SENTRON Configuration Manual Edition 10/2015 siemens.com/lowvoltage 2 Introduction LD main control and EMERGENCY-STOP switches up to 250 A 4 Introduction 7 Front mounting 10 Floor mounting 11 Distribution

More information

MS25, MST25, MS20, MST20

MS25, MST25, MS20, MST20 Versions: - MS25 with thermal and magnetic releases - MST25 with a thermal release - MS20 - with thermal and magnetic releases for single-phase consumers - MST20 with a thermal for single phase consumers

More information

Varius SUMMARY OF MODELS

Varius SUMMARY OF MODELS Varius SUMMARY OF MODELS Type FH00 FH1 FH2 FH3 LTL4a Rated operating current I e 160 A 160 A 250 A 400 A 630 A 1 600 A Rated operating voltage AC/DC U e 690 V 690 V 690 V 690 V 690 V 690 V Size 000 00

More information

PANEL PANEL MOUNTING COMPONENTS

PANEL PANEL MOUNTING COMPONENTS PANEL PANEL MOUNTING COMPONENTS For conventional wiring, Wöhner offers a comprehensive range of panel components for fastening to a DIN rail or mounting plate. The fuses and associated connection technology

More information

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU 200 M is ABB s solution for UL 489 branch

More information

High-voltage high-breaking capacity VV fuse-links

High-voltage high-breaking capacity VV fuse-links High- high- VV fuse-links [A] (ka) [mω] [W] [A 2 s] [A 2 s] 12 580 4 6,1 57 4 A 20 370 9 17,3 164 6 A 25 260 10 36 340 10 A 46 55 7 161 1 530 16 A 60 37 13 250 2 270 20 A 80 30 15 430 3 750 25 A 105 25

More information

Safety switches with separate actuator

Safety switches with separate actuator Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD5 VF KEYD6 VF KEYD7 VF KEYD8 VF KEYD10 VF KEYD11 ACTUATORS CONTACT BLOCKS FR FX FK FW 5 6 7 11 1 14 NC NC

More information

Snap-in covers I Voltage taps

Snap-in covers I Voltage taps ACCESSORIES Accessories for analogue instruments, current transformers, switchboards, voltage taps for busbars and round conductors. Snap-in covers I Voltage taps Voltage taps page 10/1 10 For analogue

More information

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories Page 1 of 5 MS132-10 ABB contact for United States of America General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: MS132-10 1SAM350000R1010 4013614400100 MS132-10

More information

Safety switches with separate actuator

Safety switches with separate actuator Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD5 ACTUATORS VF KEYD6 VF KEYD7 VF KEYD8 VF KEYD10 VF KEYD11 FR FX FK FW 5 6 7 11 1 14 NC NC slow action slow

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A Fuse protection fuser_737_a_1_cat.eps fuser_738_a_1_cat.eps The solution for > Motor load break > Protection of industrial processes FUSERBLOC REAR / FRONT connections 3 x 250 A fuser_739_a_1_cat.eps Strong

More information

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX IEC-Contactor RSC 1 Features Rated operational current 9 63 (C-3) Coil voltages C 24, 230V 3 main contacts and auxiliary contact Extendable with auxiliary contact block Mounting position any 2 Description

More information

FL series position switches

FL series position switches FL series position switches Selection diagram 0 08 0 9 0 0 0 Ball Ø. External rubber Ball Ø 8 mm, mm, stainless Glass fibre rod gasket stainless steel steel Adjustable lever Adjustable safety lever Bistable

More information

Modulostar US10 Modular fuse-holders

Modulostar US10 Modular fuse-holders Modulostar US10 FUSE HOLDERS, FUSE BASES AND SUPPORTS UL/CSA FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive Modulostar range of Mersen fuse-holders. are finger-safe under IEC standards

More information

Position switches FD series

Position switches FD series Position switches FD series Selection diagram 01 08 11 18 19 02 04 05 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fibber glass rod gasket sphere sphere 51 52 5 56 41 42 adjustable lever

More information

Motorized switch-disconnectors OTM 40 to 125 Amperes

Motorized switch-disconnectors OTM 40 to 125 Amperes Motorized switch-disconnectors OTM to 125 mperes With the new range of motorized-switch disconnectors, BB offers now a full range from to 2500 mperes. Thanks to the design, OTM...125 are a good solution

More information

Bussmann NH Bases. Technical Data Effective October Product description: Standard features:

Bussmann NH Bases. Technical Data Effective October Product description: Standard features: Technical Data 10163 Bussmann NH Bases Product description: Bussmann s range of NH bases has been designed with thermoplastic bodies, DIN-Rail and/or screw mounting (size 4 screw mounting only). This range

More information

Vertical fuse disconnects

Vertical fuse disconnects THE NAME FOR SAFETY Vertical fuse disconnects Vertical fuse disconnects Vertical fuse disconnects are designed to receive NH fuse links. Hinged fusecarriers enable opening and closing operation in electric

More information

NH HRC Fuses. IEC & British Standard Fuses NHG B

NH HRC Fuses. IEC & British Standard Fuses NHG B NH HRC Fuses NHG B Specifications Class: gg/ g L Description: DIN square bodied, dual indication industrial fuses. Construction: Steatite insulator, corrosionproof (aluminum) metal parts with full-contact,

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

Vistop TM isolating switches 63 to 160A

Vistop TM isolating switches 63 to 160A DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary

More information

HelioProtection HP15NH Photovoltaic fuse-links gpv 1500VDC

HelioProtection HP15NH Photovoltaic fuse-links gpv 1500VDC SPECIAL PURPOSE FUSES PHOTOVOLTAIC FUSES FEATURES & BENEFITS Mersen HP15NH photovoltaic (PV) fuse serie was engineered and designed specifically for the protection of photovoltaic systems. Helio-Protection

More information

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV Switch Disconnectors Introduction Siemens AG 2010 Overview 3NP5 0 3NP5 2 3NP5 fuse disconnector range 3NP5 4 SENTRON 3NP5 fuse disconnectors are controls for the occasional manual ing/isolating of loads

More information

Safety rope switches with reset for emergency stop

Safety rope switches with reset for emergency stop Safety rope switches with reset for emergency stop Selection diagram 8 8 83 ACTUATORS ACTUATORS CONTACT BLOCKS 18 9 21 1NO+ FP FD FL FC 22 33 34 LED signalling light CONDUIT ENTRIES For other available

More information

NH Solid Blades 690 VAC sizes 000 to 3

NH Solid Blades 690 VAC sizes 000 to 3 NH Solid Blades 6 VAC sizes 000 to gs-class Protistor NH 6 VAC fuse-links provide maximum flexibility in equipment design and ultimate protection for today s power conversion equipment. This range is a

More information

BSL Size 1 250A, Size 2 400A, Size 3 630A, 690VAC

BSL Size 1 250A, Size 2 400A, Size 3 630A, 690VAC BSL Size 1 250A, Size 2 400A, Size 3 630A, 690VAC FUSE RAILS IEC NH FUSE RAILS FEATURES & BENEFITS Installation on to Dimensions of s and cable connections are equivalent to those of MULTIVERT APPLICATIONS

More information

W DATA SHEET: COMBINED FAULT-CURRENT PROTECTIVE SWITCH, SERIES BOLF, 3P+N

W DATA SHEET: COMBINED FAULT-CURRENT PROTECTIVE SWITCH, SERIES BOLF, 3P+N W DATA SHEET: COMBINED FAULT-CURRENT PROTECTIVE SWITCH, SERIES BOLF, 3P+N W SCHRACK-INFO Typ A (pulse) Connection on both sides are possible Tripping independent of line voltage Additional connection capability

More information

DX³ RCCBs - ID 4P up to 100 A

DX³ RCCBs - ID 4P up to 100 A 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX³ s - ID CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Safety rope switch with reset for emergency stop

Safety rope switch with reset for emergency stop Safety rope switch with reset for emergency stop Selection diagram 8 8 83 ACTUATORS ACTUATORS CONTACT BLOCKS 18 9 21 1NO+,, FP FD FL FC 22 33 34,, CONDUIT ENTRIES Threaded conduit entries (standard) With

More information

INNOZED D0 fuse-bases with touch protection

INNOZED D0 fuse-bases with touch protection D0 fusebases with touch protection D0 fusebases with touch protection FUSE HOLDERS, FUSE BASES AND SUPPORTS IEC D0 & D FUSE BASES FEATURES & BENEFITS is a fuse base for D0 fuselinks, sizes D0 and D02.

More information

Technical Brochure. Rotary Type Installation Switches A, 500 V. Brochure OT_M 22 GB D Low Voltage Products

Technical Brochure. Rotary Type Installation Switches A, 500 V. Brochure OT_M 22 GB D Low Voltage Products 94 D 5384 Technical Brochure Rotary Type nstallation Switches 16...160 A, 500 V Brochure T_M 22 GB 99-08 Low Voltage Products 9809CD03 Rotary Type nstallation Switches 16 A...160 A ew features for installation

More information

MULTIVERT 250A Size 1, 690VAC

MULTIVERT 250A Size 1, 690VAC MULTIVERT 250A IEC FUSE SWITCH DISCONNECTORS NH VERTICAL FUSE SWITCH DISCONNECTOR FEATURES & BENEFITS MULTIVERT NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors.

More information

Low Voltage Fuses. Safety in Focus. ZVEI.ppt / / 1

Low Voltage Fuses. Safety in Focus. ZVEI.ppt / / 1 Low Voltage Fuses Safety in Focus ZVE.ppt / 05.01 / 1 Applications, Product Advantages Fuses protect Human life Electrical circuits Electrical products Electronics Cables and conductors Product advantages

More information

LR-LX-LK-LW Safety Switches with separate actuator

LR-LX-LK-LW Safety Switches with separate actuator LR-LX-LK-LW Safety Switches with separate actuator Technopolymer housing, from one to three conduit entries Protection degree IP67 15 contact blocks available 8 stainless steel actuators available Versions

More information

Mini DC - Isolators for Photovoltaic

Mini DC - Isolators for Photovoltaic Mini DC - Isolators for Photovoltaic acc. to IEC 60364-7-712 Quality made in D1024E171 Technical catalogues and news under: www.benedict.at Contactors Motor-Starter Mini-Contactors Contactors Overload

More information

F E - Electromagnetic Safety Switch With Separated Actuator. 1 Code Construction. Casing: P: Plastic casing

F E - Electromagnetic Safety Switch With Separated Actuator. 1 Code Construction. Casing: P: Plastic casing Electromagnetic Safety Switch With Separated 1 Code Construction F E - Casing: P: Plastic casing Cable inlet: 5: 3 x (M20x1) Type of FEP: E: Electrical block ( b with excited ) M: Mechanical block ( b

More information

L O W V O L T A G E DISCONNECT SWITCHES G LO B A L L I N E OF PREMIUM C O M PA C T LOW VOLTAGE SWITCHGEAR

L O W V O L T A G E DISCONNECT SWITCHES G LO B A L L I N E OF PREMIUM C O M PA C T LOW VOLTAGE SWITCHGEAR L O W V O L T A G E DISCONNECT SWITCHES G LO B A L L I N E OF PREMIUM C O M PA C T LOW VOLTAGE SWITCHGEAR The safest way to switch power on and off in your industrial control panels. Your problem: You

More information

vertical fuse switch disconnectors

vertical fuse switch disconnectors SWITCHGEAR ARS vertical fuse switch disconnectors - touch protection IP 30 from the front - fibre glass extra strenghtened, self extinguishing thermoplastics - double clearance between open contacts -

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

25A 25A 32A 40A 40A 63A 63A 80A

25A 25A 32A 40A 40A 63A 63A 80A ISDC Compact Range 25A - 200A Control Panel Isolation Equipment Craig & Derricott has ranges of Switch-Disconnectors, Fuse Combination Units and Changeover Isolators for panel mounting ranging from 25A

More information

MS General Information Extended Product Type: MS

MS General Information Extended Product Type: MS MS132-1.6 General Information Extended Product Type: MS132-1.6 Product ID: 1SAM350000R1006 EAN: 4013614400063 Catalog Description: MS132-1.6 Manual Motor Starter Long Description: The MS132-1.6 manual

More information

Complete and reliable solar circuit protection

Complete and reliable solar circuit protection Contents Photovoltaic fuses, holders, and blocks 6 Complete and reliable solar circuit protection Description Fuses Fuse size Volts Amps PVM 13/32" x 1-1/2" 600 4-30 PVS-R RK5 600 20-400 Section page PV-_A10_

More information

NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4

NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4 NH fuse-links am 500-690VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions according to DIN 43 620 Parts 1 to 4 Lead free contact blades 0% cadmium APPLICATIONS am: Partial purpose,

More information

CONTA-CONNECT SUPPLEMENTS

CONTA-CONNECT SUPPLEMENTS CONTA-CONNECT SUPPLEMENTS CONTA-CONNECT system HSKG High-power stud terminals HSKG The newest generation of stud terminals from CONTA-CLIP offers secure connections for all energy-transmitting applications.

More information