Fuse Switch Disconnectors XNH. Fuse Switch Disconnectors XNH... For fuse links NH000 to NH3. Rated operating current of 160, 250, 400 and 630A

Size: px
Start display at page:

Download "Fuse Switch Disconnectors XNH. Fuse Switch Disconnectors XNH... For fuse links NH000 to NH3. Rated operating current of 160, 250, 400 and 630A"

Transcription

1 Panel Building Accessories PIFT Plug In Fused Terminal Fuse Disconnectors Thermostats Filters and Fans Terminals Electrical Cabinet Heating Catalogue 2016

2 Fuse Switch Disconnectors XNH Fuse Switch Disconnectors XNH... vt61615 For fuse links NH000 to NH3 Rated operating current of 160, 250, 400 and 630A Sizes 00, 1, 2 and 3 Degree of protection IP2XC Frame widths of 106, 184, 210 and 250 mm vt64215 For mounting plate, DIN rail and busbar system of 60 mm System size 195 and 300 mm Can be locked with a pad lock Current-theft protection Flex-System for cable connection at the top/bottom Improved operator safety vt64015 Flat connection for cable lug, box terminal, clamp-type terminal, prism terminal and double prism terminal Switch cover with safety parking position Fuse monitoring light with LED on the device Electronic fuse monitoring SmartWire-DT option vt EATON CORPORATION CA008008EN

3 Fuse Switch Disconnectors XNH System Overview 3-pole XNH00 XNH1 XNH2 XNH3 Basic device n n n n Fuse control - light n n n n Fuse control - electronic n n n n Setup options XNH00 XNH1 XNH2 XNH3 Busbar system 60mm n n n n Mounting plate n n n n DIN rails n n - - Standard connection options XNH00 XNH1 XNH2 XNH3 Flat connection n n n n Installation distribution board box terminal BT2 1) n Box terminal n n n n SmartWire-DT Module XNH00 XNH1 XNH2 XNH3 Complete set for direct mounting on the switchgear (with 2 DX) n n n n For fixing on the mounting plate (with 2 DX) n n n n System Overview Accessories XNH00 XNH1 XNH2 XNH3 DIN rail fastening n n - - Locking device n n n n Current-theft protection n n n n Switch position indicator n n n n Mechanical fuse monitoring n n n n Internal lock for contact protection n n n n Clamp-type terminal n n n n Prism terminal n n n n Double-prism terminal - n n n Box terminal - n n n Extinguishing chambers - n n n Spare handle cover n n n n Connection kit, 2 and 4 poles n n - n Cover supports n n n n Reach-over protection at busbar n n n n Cover for connection area n n n n Extension of the cover for the connection area n Height compensation adapter n ) Deeper-positioned box terminal with busbar-devices for improved connection when using front panels, e.g. installation distribution boards. 2 EATON CORPORATION CA008008EN

4 Fuse Switch Disconnectors XNH Fuse Switch Disconnectors XNH Degree of protection IP2XC in operating mode According to IEC/EN AC 690 V / DC 440 V Conditional rated short-circuit current 120kA (500V) and 100kA (690V) Reaction to fire according to UL 94, self-extinguishing Current paths of electrolytic copper, silver-plated For fixing on mounting plates and DIN rails Fuse Control Light with optical signalling of triggered fuse-links Fuse Control FCE with electronic monitoring of fuse-links vt64015 Size Type of connection I e (A) Type Article No. Pack designation (pcs.) Basic 3-pole for mounting plate vt Flat connection M8 max. 95 mm² 160 XNH00-A Box terminal mm² 160 XNH00-A160-BT Flat connection M10 max. 150 mm² 250 XNH1-A Box terminal mm² 250 XNH1-A250-BT Flat connection M10 max. 240 mm² 400 XNH2-A Box terminal mm² 400 XNH2-A400-BT Flat connection M10 max. 300 mm² 630 XNH3-A Box terminal mm² 630 XNH3-A630-BT Fuse Control Light 3-pole for mounting plate wa_vt Flat connection M8 max. 95 mm² 160 XNH00-FCL-A Box terminal mm² 160 XNH00-FCL-A160-BT Flat connection M10 max. 150 mm² 250 XNH1-FCL-A Box terminal mm² 250 XNH1-FCL-A250-BT Flat connection M10 max. 240 mm² 400 XNH2-FCL-A Box terminal mm² 400 XNH2-FCL-A400-BT Flat connection M10 max. 300 mm² 630 XNH3-FCL-A Box terminal mm² 630 XNH3-FCL-A630-BT Fuse Control FCE 3-pole for mounting plate vt Flat connection M8 max. 95 mm² 160 XNH00-FCE-A Box terminal mm² 160 XNH00-FCE-A160-BT Flat connection M10 max. 150 mm² 250 XNH1-FCE-A Box terminal mm² 250 XNH1-FCE-A250-BT Flat connection M10 max. 240 mm² 400 XNH2-FCE-A Box terminal mm² 400 XNH2-FCE-A400-BT Flat connection M10 max. 300 mm² 630 XNH3-FCE-A Box terminal mm² 630 XNH3-FCE-A630-BT pole for mounting plate 00 Flat connection M8 max. 95 mm² 160 XNH00-1-A Box terminal mm² 160 XNH00-1-A160-BT Flat connection M10 max. 150 mm² 250 XNH1-1-A Box terminal mm² 250 XNH1-1-A250-BT Flat connection M10 max. 300 mm² 400/630 XNH32-1-A Box terminal mm² 400/630 XNH32-1-A630-BT EATON CORPORATION CA008008EN

5 Fuse Switch Disconnectors XNH Fuse Switch Disconnectors XNH Degree of protection IP2XC in operating mode According to IEC/EN AC 690 V / DC 440 V Conditional rated short-circuit current 120kA (500V) and 100kA (690V) Reaction to fire according to UL 94, self-extinguishing Current paths of electrolytic copper, silver-plated For fixing on busbars of 60mm (SASY 60i) Cable connection optionally at the top or bottom Fuse Control Light with optical signalling of triggered fuse-links Fuse Control FCE with electronic monitoring of fuse-links vt64215 Size Type of connection I e (A) Type Article No. Pack designation (pcs.) Basic 3-pole for SASY 60i vt Flat connection M8 max. 95 mm² 160 XNH00-S Box terminal mm² 160 XNH00-S160-BT Box terminal mm² 160 XNH00-S160-BT Flat connection M10 max. 150 mm² 250 XNH1-S Box terminal mm² 250 XNH1-S250-BT Flat connection M10 max. 240 mm² 400 XNH2-S Box terminal mm² 400 XNH2-S400-BT Flat connection M10 max. 300 mm² 630 XNH3-S Box terminal mm² 630 XNH3-S630-BT Fuse Control Light 3-pole for SASY 60i wa_vt Flat connection M8 max. 95 mm² 160 XNH00-FCL-S Box terminal mm² 160 XNH00-FCL-S160-BT Box terminal mm² 160 XNH00-FCL-S160-BT Flat connection M10 max. 150 mm² 250 XNH1-FCL-S Box terminal mm² 250 XNH1-FCL-S250-BT Flat connection M10 max. 240 mm² 400 XNH2-FCL-S Box terminal mm² 400 XNH2-FCL-S400-BT Flat connection M10 max. 300 mm² 630 XNH3-FCL-S Box terminal mm² 630 XNH3-FCL-S630-BT Fuse Control FCE 3-pole for SASY 60i vt Flat connection M8 max. 95 mm² 160 XNH00-FCE-S Box terminal mm² 160 XNH00-FCE-S160-BT Box terminal mm² 160 XNH00-FCE-S160-BT Flat connection M10 max. 150 mm² 250 XNH1-FCE-S Box terminal mm² 250 XNH1-FCE-S250-BT Flat connection M10 max. 240 mm² 400 XNH2-FCE-S Box terminal mm² 400 XNH2-FCE-S400-BT Flat connection M10 max. 300 mm² 630 XNH3-FCE-S Box terminal mm² 630 XNH3-FCE-S630-BT pole for SASY 60i 00 Flat connection M8 max. 95 mm² 160 XNH00-1-S EATON CORPORATION CA008008EN

6 Fuse Switch Disconnectors XNH SmartWire-DT, Basic Module Kit Kit consisting of SWD module, ready-made cables and additional cover for cable area Only in connection with Fuse Control FCE Description Suitable Type Article No. Pack for size designation (pcs.) 2723PIC-197 Basic module with 2 digital inputs for 00 with FCE XNH00-SWD-KIT switch position indication and trip 1 with FCE XNH1-SWD-KIT signal. Complete set for direct 2 with FCE XNH2-SWD-KIT mounting at the switchgear. 3 with FCE XNH3-SWD-KIT Basic module with 2 digital inputs for 00 with FCE XNH00-SWD-KIT-EXT switch position indication and trip 1/2/3 with FCE XNH123-SWD-KIT-EXT signal. For fixing on the mounting plate. SmartWire-DT, Modules Description Suitable Type Article No. Pack for size designation (pcs.) 2723PIC-198 Basic module with 2 digital inputs 00/1/2/3 XNH-SWD-2DX with FCE Advanced module with 2 digital and 3 00/1/2/3 XNH-SWD-2DX-3AX analogue inputs with FCE Cover for connection area, 3-pole Description Suitable Type Article No. Pack for size designation (pcs.) vt09816 Cable entries can be knocked out as 00 XNH00-XKSA required. 36, 42 and 66 mm length for 00 XNH00-XKSA top and bottom. Multiple use per 1 XNH1-XKSA device is possible. 2 XNH2-XKSA XNH3-XKSA Cover for connection area, 1-pole Description Suitable Type Article No. Pack for size designation (pcs.) Cable entries can be knocked out as 00 XNH00-1-XKSA required. 36, 42 and 66 mm length for 00 XNH00-1-XKSA top and bottom. Multiple use per 1 XNH1-1-XKSA device is possible. 3 (2) XNH3-1-XKSA Extension for cover of connection area, 3-pole for SASY 60i Description Suitable Type Article No. Pack for size designation (pcs) vt10016 Can be fixed at the top or bottom of 00 XNH00-XKSV the device. 32 or 39 and 34 mm distance 00 XNH00-XKSV to the base plate. 5 EATON CORPORATION CA008008EN

7 Fuse Switch Disconnectors XNH Reach-over protection, 3-pole for SASY 60i Can be fixed at the top or bottom of the device For 32 or 39 and 34mm distance to the base plate Description Suitable Type Article No. Pack for size designation (pcs.) vt09916 For flat connection or box terminal 00 XNH00-XKSS XNH00-XKSS For BT2 box terminal 00 XNH00-XKSS-BT XNH00-XKSS-BT For flat connection or box terminal 1 XNH1-XKSS XNH1-XKSS XNH2-XKSS XNH2-XKSS XNH3-XKSS XNH3-XKSS Height compensation adapter 20mm, 3-pole Description Suitable Type Article No. Pack for size designation (pcs.) vt67015 Compensation adapter top/bottom 00 XNH00-XHAA-T/B Level 70 => 90mm Side compensation profiles 00 XNH00-XHAA-R/L Level 70 => 90mm Cover supports Description Suitable Type Article No. Pack for size designation (pcs.) vt10616, vt10416 Top and bottom 00 XNH00-XCS-T/B Level 60, 70 mm Side 00 XNH00-XCS-R/L Level 32, 60, 70 mm Top and bottom, side 1, 2, 3 XNH123-XCS Level 32, 60, 70 mm Current-theft protection Description Suitable Type Article No. Pack for size designation (pcs.) vt10916 For manipulation-protected 00, 1, 2, 3 XNH-XSECUR set blocking of the inspection window Note: 1 set includes current-theft protection for a 3-pole XNH. DIN-rail fastener Description Suitable Type Article No. Pack for size designation (pcs.) vt68115 For mounting XNH disconnectors 00 XNH00-XRAIL on 2x DIN rails EN XNH1-XRAIL EATON CORPORATION CA008008EN

8 Fuse Switch Disconnectors XNH Locking device Description Suitable Type Article No. Pack for size designation (pcs.) vt11016 For locking with a padlock 00, 1, 2, 3 XNH-XLOCK when using a closed XNH disconnector Note: Padlock with a shackle diameter of 6mm max. Device locking with sign Description Suitable Type Article No. Pack for size designation (pcs.) vt11116 For keyless locking of the XNH switching 00, 1, 2, 3 XNH-XLDG-G devices in combination with XNH-XLOCK. Language German. Internal lock for contact-protection Description Suitable Type Article No. Pack for size designation (pcs.) wa_vt15815 Tool-requiring lock of internal 00, 1, 2, 3 XNH-XLATCH contact protection covers Switch position indicator Description Suitable Type Article No. Pack for size designation (pcs.) vt change-over contact, AC 250V, 10/3A 00 XNH00-XPOS , 2, 3 XNH123-XPOS Mechanical fuse monitoring Description Suitable Type Article No. Pack for size designation (pcs.) vt change-over contact, AC 250V, 10/3A 00 XNH00-XMFM Note: Only in combination with NH fuse links equipped with a striker pin. Not for use in combination with box terminal or double-prism terminals. 1, 2, 3 XNH123-XMFM Conncection kit, 2 and 4 poles Description Suitable Type Article No. Pack for size designation (pcs.) To mechanically connect 00, 1, 3/(2) XNH-XLINK x 1-pole or 3-pole+ 1-pole XNH disconnectors 7 EATON CORPORATION CA008008EN

9 Fuse Switch Disconnectors XNH Connection technology vt68215 vt67515 vt67315 Description Suitable Type Article No. Pack for size designation (pcs.) Clamp-type terminal mm², Cu 00 XNH00-XCT mm², Cu 1 XNH1-XCT mm², Cu 2 XNH2-XCT CU-BAND-11x21x1 3 XNH3-XCT Prism terminal mm², Cu/Al 00 XNH00-XPRC mm², Cu/Al 1 XNH1-XPRC mm², Cu/Al 2 XNH2-XPRC mm², Cu/Al 3 XNH3-XPRC Double-prism terminal 2 x mm², Cu/Al 1 XNH1-X2PRC x mm², Cu/Al 2 XNH2-X2PRC x mm², Cu/Al 3 XNH3-X2PRC vt68615 Box terminal mm², Cu/Al 1 XNH1-BT mm², Cu/Al 2, 3 XNH23-BT Note: Box terminal and double-prism terminal not for use in combination with mechanical fuse monitoring XNH -XMFM. Spare handle cover, 3-pole Description Suitable Type Article No. Pack for size designation (pcs.) vt08016 Cover for XNH disconnector Basic 00 XNH00-XGRIP XNH1-XGRIP XNH2-XGRIP XNH3-XGRIP vt08116 Cover for XNH disconnector with 00 XNH00-XGRIP-FCL Fuse Control FCL 1 XNH1-XGRIP-FCL XNH2-XGRIP-FCL XNH3-XGRIP-FCL vt08216 Cover for XNH disconnector with 00 XNH00-XGRIP-FCE Fuse Control FCE 1 XNH1-XGRIP-FCE XNH2-XGRIP-FCE XNH3-XGRIP-FCE Spare extinguishing chambers, 3-pole Note: FCL and FCE can only be used with fuse links equipped with live handle straps. Description Suitable Type Article No. Pack for size designation (pcs.) For XNH disconnector Basic, FCL, FCE 1, 2, 3 XNH-XARC Note: 1 set includes extinguishing chambers for a 3-pole XNH disconnector. 8 EATON CORPORATION CA008008EN

10 Fuse Switch Disconnectors XNH Replacing NH fuses or any other activities (such as installation, operation etc. ) on NH fuse switch disconnectors may be carried out by electro-technically qualified and specialized staff only. Power-related data provided by the manufacturer, e.g. max. rated make and break capacities, must be taken into account. Non-qualified employees are not authorized to install or operate such products as they cannot foresee the consequences of their actions. General regulations (e.g. safety regulations, protective clothing ) and regional requirements (e.g. for accident prevention on electrical systems and operating resources) must at all times be respected. Technical Data XNH00 -A160 XNH00 -S160 XNH1 -A250 XNH1 -S250 Standard IEC/EN IEC/EN IEC/EN IEC/EN NH fuses 1) according to DIN VDE / / Rated operating voltage U e V AC 690, DC 440 AC 690, DC 440 AC 690, DC 440 AC 690, DC 440 Rated operating current I e A Rated frequency f Hz Rated insulation voltage U i V AC 800 AC 800 AC 800 AC 800 Total power loss at I th (without fuses) P v W Power loss at 80% (without fuses) P v W Rated impulse withstand voltage U imp kv Utilization category AC-23B (400V/160A) AC-23B (400V/160A) AC-23B (400V/250A) AC-23B (400V/250A) AC-22B (500V/160A) AC-22B (500V/160A) AC-22B (500V/250A) AC-22B (500V/250A) AC-21B (690V/160A) AC-21B (690V/160A) AC-21B (690V/250A) AC-21B (690V/250A) DC-22B (250V/160A) DC-22B (250V/160A) DC values on DC values on DC-21B (440V/160A) DC-21B (440V/160A) request request Conditional rated short-circuit current ka 120 (500V) 120 (500V) 120 (500V) 120 (500V) 100 (690V) 100 (690V) 100 (690V) 100 (690V) Rated short-time withstand current I cw ka Max. permitted power loss per fuse link P NH W Degree of protection - front (XNH installed) Operating status IP20 Operating status IP20 Operating status IP20 Operating status IP20 Contact prot. IP2XC Contact prot. IP2XC Contact prot. IP2XC Contact prot. IP2XC Handle cover open IP10 Handle cover open IP10 Handle cover open IP10 Handle cover open IP10 Ambient temperature T 35 C -25 to to to to +55 Rated operating mode Permanent operation Permanent operation Permanent operation Permanent operation Activation Dependent Dependent Dependent Dependent manual activation manual activation manual activation manual activation Position Vertical/horizontal Vertical/horizontal Vertical/horizontal Vertical/horizontal Altitude m max max max max Degree of pollution Overvoltage category III III III III Colour Grey Grey Grey Grey RoHs Yes Yes Yes Yes Energy feeder direction Any Any (FLEX System) Any Any (FLEX System) Lockable Yes, optional Yes, optional Yes, optional Yes, optional Sealable Yes, standard Yes, standard Yes, standard Yes, standard Material Polyamide Polyamide Polyamide Polyamide Reaction to fire Self-extinguishing Self-extinguishing Self-extinguishing Self-extinguishing acc. to UL94 acc. to UL94 acc. to UL94 acc. to UL94 Halogen-free Yes Yes Yes Yes Voltage test Yes, sliding in- Yes, sliding in- Yes, sliding in- Yes, sliding inspection windows spection windows spection windows spection windows Electrical service life (operating cycles) Mechanical service life (operating cycles) Track resistance CTI 600 CTI 600 CTI 600 CTI 600 Temperature resistance up to C Terminal capacities: Flat connection Bolt diameter M8 M8 M10 M10 Cable lug max. width mm Flat rail mm 20x10 20x10 30x10 30x10 Box terminal multi-wire mm² Cu Cu Cu/Al Cu/Al Cu-Band 9x9x0.8 9x9x0.8 10x16x0.8 10x16x0.8 Clamp-type terminal multi-wire mm² Cu Cu Cu Cu Cu-Band 6x9x0.8 6x9x0.8 6x16x0.8 6x16x0.8 Prism terminal multi-wire mm² Cu/Al Cu/Al Cu/Al Cu/Al Double-prism terminal multi-wire mm² - - 2x (70-95) Cu/Al 2x (70-95) Cu/Al Note: Please leave a minimum distance to grounded live parts: Side = 20 mm, top = 50 mm. Exception DC-21B: Side = 50 mm, top = 100 mm (valid for XNH00 ). 1) Type-tested with NH fuse links of characteristic gg. Safety control FCE and FCL only in combination with NH fuses equipped with live handle straps. 9 EATON CORPORATION CA008008EN

11 Fuse Switch Disconnectors XNH Replacing NH fuses or any other activities (such as installation, operation etc. ) on NH fuse switch disconnectors may be carried out by electro-technically qualified and specialized staff only. Power-related data provided by the manufacturer, e.g. max. rated make and break capacities, must be taken into account. Non-qualified employees are not authorized to install or operate such products as they cannot foresee the consequences of their actions. General regulations (e.g. safety regulations, protective clothing ) and regional requirements (e.g. for accident prevention on electrical systems and operating resources) must at all times be respected. Technical Data XNH2 -A400 XNH2 -S400 XNH3 -A630 XNH3 -S630 Standard IEC/EN IEC/EN IEC/EN IEC/EN NH fuses 1) acc. to DIN VDE / 2 3 / 2 Rated operating voltage U e V AC 690, DC 440 AC 690, DC 440 AC 690, DC 440 AC 690, DC 440 Rated operating current I e A Rated frequency f Hz Rated insulation voltage U i V AC 800 AC 800 AC 800 AC 800 Total power loss at I th (without fuses) P v W Power loss at 80% (without fuses) P v W Rated impulse withstand voltage U imp kv Utilization category AC-23B (400V/400A) AC-23B (400V/400A) AC-23B (400V/630A) AC-23B (400V/630A) AC-22B (500V/400A) AC-22B (500V/400A) AC-22B (500V/630A) AC-22B (500V/630A) AC-21B (690V/400A) AC-21B (690V/400A) AC-21B (690V/630A) AC-21B (690V/630A) DC values on DC values on DC values on DC values on request request request request Conditional rated short-circuit current ka 120 (500V) 120 (500V) 120 (500V) 120 (500V) 100 (690V) 100 (690V) 100 (690V) 100 (690V) Rated short-time withstand current I cw ka Max. permitted power loss per fuse link P NH W Degree of protection - front (XNH installed) Operating status IP20 Operating status IP20 Operating status IP20 Operating status IP20 Contact prot. IP2XC Contact prot. IP2XC Contact prot. IP2XC Contact prot. IP2XC Handle cover open IP10 Handle cover open IP10 Handle cover open IP10 Handle cover open IP10 Ambient temperature T 35 C -25 to to to to +55 Rated operating mode Permanent operation Permanent operation Permanent operation Permanent operation Activation Dependent Dependent Dependent Dependent manual activation manual activation manual activation manual activation Position Vertical/horizontal Vertical/horizontal Vertical/horizontal Vertical/horizontal Altitude m max max max max Degree of pollution Overvoltage category III III III III Colour Grey Grey Grey Grey RoHs Yes Yes Yes Yes Energy feeder direction Any Any (FLEX System) Any Any (FLEX System) Lockable Yes, optional Yes, optional Yes, optional Yes, optional Sealable Yes, standard Yes, standard Yes, standard Yes, standard Material Polyamide Polyamide Polyamide Polyamide Reaction to fire Self-extinguishing Self-extinguishing Self-extinguishing Self-extinguishing acc. to UL94 acc. to UL94 acc. to UL94 acc. to UL94 Halogen-free Yes Yes Yes Yes Voltage test Yes, sliding in- Yes, sliding in- Yes, sliding in- Yes, sliding inspection windows spection windows spection windows spection windows Electrical service life (operating cycles) Mechanical service life (operating cycles) Track resistance CTI 600 CTI 600 CTI 600 CTI 600 Temperature resistance up to C Terminal capacities: Flat connection Bolt diameter M10 M10 M10 M10 Cable lug max. width mm Flat rail mm 40x10 40x10 50x10 50x10 Box terminal multi-wire mm² Cu/Al Cu/Al Cu/Al Cu/Al Cu-Band 6x16x0.8 up to 6x16x0.8 up to 6x16x0.8 up to 6x16x0.8 up to 10x32x1 10x32x1 10x32x1 10x32x1 Clamp-type terminal multi-wire mm² Cu Cu on request on request Cu-Band 10x16x0.8 10x16x0.8 11x21x1 11x21x1 Prism terminal multi-wire mm² Cu/Al Cu/Al Cu/Al Cu/Al Double-prism terminal multi-wire mm² 2x ( ) Cu/Al 2x ( ) Cu/Al 2x ( ) Cu/Al 2x ( ) Cu/Al Note: Please leave a minimum distance to grounded live parts: Side = 20 mm, top = 50 mm. 1) Type-tested with NH fuse links of characteristic gg. Safety control FCE and FCL only in combination with NH fuses equipped with live handle straps. 10 EATON CORPORATION CA008008EN

12 Fuse Switch Disconnectors XNH Technical Data Connection of laminated copper band (CU-BAND ) to XNH fuse switch disconnectors with box terminal BT Number of layers x Width x Thickness of layers = Cross-section (mm 2 ) Hight copper band (mm) Max. rated operating current (A) XNH00 -BT XNH1 -BT XNH2 -BT XNH3 -BT 3 x 9 x 0.8 = x x x 9 x 0.8 = x x x 9 x 0.8 = x x x 16 x 0.8 = x x x 10 x 16 x 0.8 = x x x 5 x 24 x 1.0 = x x 11 x 21 x 1.0 = x x 8 x 24 x 1.0 = x x 10 x 24 x 1.0 = x x 5 x 32 x 1.0 = x x 10 x 32 x 1.0 = x x 10 x 40 x 1.0 = x 50 x 1.0 = x 80 x 1.0 = mm (0.53") mm (0.52") 21.9 mm (0.86") 14.5 mm (0.57") 32 mm (1.26") 19 mm (0.75") 4 mm (0.16") 32 mm (1.26") 18 mm (0.71") 5 mm 0.2") 11 EATON CORPORATION CA008008EN

13 Fuse Switch Disconnectors XNH Technical Data XNH FCE Power supply V Self-supplied Power consumption VA 1.5 Overvoltage category 230/400V : III 500V : II Frequency range HZ Input resistance >1 kohm/v Voltage inputs V AC (+/-10%) Temperature range C -5 to +55 Operation indicator 1 LED green Failure indicator 3 LEDs (F1, F2, F3) red IP degree of protection IP3X Function test Test button for relay + LEDs EMC IEC / IEC Fuse links NH with live handle straps Outputs Relay output 1 NC, 1 NO Max. voltage V AC 250 / DC 24 Max. switching current A 1 Circuit diagram Function diagram Note: Not suitable for single-phase application! 12 EATON CORPORATION CA008008EN

14 Fuse Switch Disconnectors XNH Dimensional drawings XNH00-A160 Fixing dimensions: top Mas_XNH00-A EATON CORPORATION CA008008EN

15 Fuse Switch Disconnectors XNH Dimensional drawings XNH00-FCE-A160 Fixing dimensions: top Mas_XNH00-FCE-A EATON CORPORATION CA008008EN

16 Fuse Switch Disconnectors XNH Dimensional drawings XNH1-A250, XNH2-A400, XNH3-A630 Type a b c e f g h1 h2 h3 i k l p q r s t1 t2 u XNH1-A Ø10, XNH2-A Ø XNH3-A Ø Fixing dimensions in mm: Type a c r v w x y XNH1-A XNH2-A XNH3-A top Mas_XNH1-A EATON CORPORATION CA008008EN

17 Fuse Switch Disconnectors XNH Dimensional drawings XNH1-FCE-A250, XNH2-FCE-A400, XNH3-FCE-A630 Type a b c d e f g h1 h2 h3 i k l p q r s t1 t2 u XNH1-FCE-A Ø10, XNH2-FCE-A Ø XNH3-FCE-A Ø Fixing dimensions in mm: Type a c r v w x y XNH1-FCE-A XNH2-FCE-A XNH3-FCE-A top Mas_XNH1-FCE-A EATON CORPORATION CA008008EN

18 Fuse Switch Disconnectors XNH Dimensional drawings XNH00-S160 Outgoing - top (Ao) Outgoing - bottom (Au) 5 or 10 Mas_XNH00-S EATON CORPORATION CA008008EN

19 Fuse Switch Disconnectors XNH Dimensional drawings XNH00-S160-BT2 Outgoing - bottom (Au) 5 or Mas_XNH00-S160-BT2_1 Outgoing - top (Ao) View A for Au Mas_XNH00-S160-BT2_2 18 EATON CORPORATION CA008008EN

20 Fuse Switch Disconnectors XNH Dimensional drawings XNH00-FCE-S160 5 or 10 Mas_XNH00-FCE-S EATON CORPORATION CA008008EN

21 Fuse Switch Disconnectors XNH Dimensional drawings XNH1-S250, XNH2-S400, XNH3-S630 Outgoing - top (Ao) Type a b c e f-au f-ao h1 h2 h3 i k l m n o p q r s t1 t2 u XNH1-S ,5 58 Ø10, XNH2-S ,5 66 Ø XNH3-S ,5 82 Ø Outgoing - bottom (Au) Mas_XNH1-S EATON CORPORATION CA008008EN

22 Fuse Switch Disconnectors XNH Dimensional drawings XNH1-FCE-S250, XNH2-FCE-S400, XNH3-FCE-S630 Mas_XNH1-FCE-S250 Type a b c d e h1 h2 h3 k m n o p q r s t1 t2 u XNH1-FCE-S XNH2-FCE-S XNH3-FCE-S EATON CORPORATION CA008008EN

23 Fuse Switch Disconnectors XNH Dimensional drawings XNH00-1-A160 Type a b c e f g h1 h2 h3 i l p q r s t1 XNH00-1-A ,5 Ø9 4, x XNH00-1-A ,5 Ø9 4, x XNH00-1-A160 2x XNH00-1-A160 Mas_XNH00-1-A160 XNH00-1-S160 Type a b c e f-ao f-au g-ao g-au h1 h2 i l n o p q r s t1 XNH00-1-S ,50, ,70, ,5 Ø , Mas_XNH00-1-S160 Cable bottom Cable top 22 EATON CORPORATION CA008008EN

24 Fuse Switch Disconnectors XNH Dimensional drawings XNH1_32_1-A Type a b c e f g h1 h2 h3 i l p q r s t1 t2 u XNH1-1-A Ø10, XNH32-1-A Ø x XNH1-1-A Ø10, x XNH32-1-A Ø XNH1-1-A XNH32-1-A 2x XNH1-1-A 2x XNH32-1-A Mas_XNH1_32_1-A 23 EATON CORPORATION CA008008EN

25 PIFT Plug in Fuse Terminal Switch-disconnector-fuse in strip version in accordance with IEC/EN 60947/3 SG04711 Secure power High availability Rapid adaptation to changing conditions during operation Low susceptibility High safety standards (personal security) Permanent monitoring of the operating modes High switching capacity in the event of overload and short-circuit A scale in Switching and Controls 24 EATON CORPORATION CA008008EN

26 PIFT Plug in Fuse Terminal Type code PIFT 1 L C10 1 B M C A E PIFT X X X X X CXX X X Designation: PIFT = Plug in Fuse Terminal Size: 0 = DIN NH-Size 00 1 = DIN NH-Size 1 2 = DIN NH-Size 2 3 = DIN NH-Size 3 Switching capacity: L = Switching capacity Normal AC22 H = Switching capacity High AC23 Number of poles: 3 = 3-pole 4 = 4-pole Number of transformers: 0 = 0 transformers 1 = 1 transformer 3 = 3 transformers 4 = 4 transformers Transformer class: 0 = no transformer 1 = class 1 5 = class 0,5 with registration mark, certified, without calibration certificate 5b = class 0,5 with registration mark, certified, with calibration certificate and specification of measuring values Current transformer (primary): C07 = 75A C30 = 300A C10 = 100 C40 = 400A C15 = 150A C50 = 500A C20 = 200A C60 = 600A C25 = 250A Current transformer (secondary): 1 = 1A 5 = 5A Wiring of the transformer: P = Prepared for mounting directly on the measuring device, plug-in terminal and auxiliary switch M = Only on measuring device B = On plug-in terminal and measuring device C = Only on plug-in terminal X X X X Measuring device: M = Prepared for a measuring device Plug-in terminal for auxiliary current wiring: C = Plug-in terminal is required for: 3-pole current measuring, inst. of an auxiliary switch, electronic fuse monitoring Auxiliary switch for switch-position indication: A = Auxiliary switch NC+NO Electronic module: E = Electronic fuse monitoring 25 EATON CORPORATION CA008008EN

27 PIFT Plug in Fuse Terminal PIFT 3-pole Version Basic terminal without accessories Max. Size Breaking Type Article No. Pack Rated operating capacity designation (pcs.) current I e (A) SG AC-22B PIFT0L AC-22B PIFT1L AC-22B PIFT2L AC-22B PIFT3L AC-23B PIFT0H AC-23B PIFT1H AC-23B PIFT2H AC-23B PIFT3H Version Basic terminal Plug-in terminal for auxiliary current wiring Electronic fuse monitoring Max. Size Breaking Type Article No. Pack Rated operating capacity designation (pcs.) current I e (A) SG AC-22B PIFT0L300CE AC-22B PIFT1L300CE AC-22B PIFT2L300CE AC-22B PIFT3L300CE AC-23B PIFT0H300CE AC-23B PIFT1H300CE AC-23B PIFT2H300CE AC-23B PIFT3H300CE Version Basic terminal 1 current transformer; class 1; secondary current 1A Transformer wiring on plug-in position of the measuring device Max. Size Breaking Transformer Type Article No. Pack Rated operating capacity class Primary Secondary designation (pcs.) current Klasse current current I e (A) (A) (A) SG AC-22B PIFT0L311C151MM AC-22B PIFT1L311C251MM AC-22B PIFT2L311C401MM AC-22B PIFT3L311C601MM AC-23B PIFT0H311C151MM AC-23B PIFT1H311C251MM AC-23B PIFT2H311C401MM AC-23B PIFT3H311C601MM EATON CORPORATION CA008008EN

28 PIFT Plug in Fuse Terminal PIFT 3-pole Version Basic terminal 3 transformers; class 1; secondary current 1A Transformer wiring on plug-in terminal Plug-in terminal for auxiliary current wiring Auxiliary switch for switch-position indication NC+NO Max. Size Breaking Transformer Type Article No. Pack Rated operating capacity class Primary Secondary designation (pcs.) current Klasse current current I e (A) (A) (A) SG AC-22B PIFT0L331C151CCA AC-22B PIFT1L331C251CCA AC-22B PIFT2L331C401CCA AC-22B PIFT3L331C601CCA AC-23B PIFT0H331C151CCA AC-23B PIFT1H331C251CCA AC-23B PIFT2H331C401CCA AC-23B PIFT3H331C601CCA Version Basic terminal 1 current transformer class 1; secondary current 5A Transformer wiring on plug-in position of the measuring device Max. Size Breaking Transformer Type Article No. Pack Rated operating capacity class Primary Secondary designation (pcs.) current Klasse current current I e (A) (A) (A) SG AC-22B PIFT0L311C155MM AC-22B PIFT1L311C255MM AC-22B PIFT2L311C405MM AC-22B PIFT3L311C605MM AC-23B PIFT0H311C155MM AC-23B PIFT1H311C255MM AC-23B PIFT2H311C405MM AC-23B PIFT3H311C605MM Version Basic terminal 1 current transformer; class 1; secondary current 1A Transformer wiring on plug-in terminal Plug-in terminal for auxiliary current wiring Auxiliary switch for switch-position indication NC+NO Electronic fuse monitoring Max. Size Breaking Transformer Type Article No. Pack Rated operating capacity class Primary Secondary designation (pcs.) current Klasse current current I e (A) (A) (A) SG AC-22B PIFT0L331C151CCAE AC-22B PIFT1L331C251CCAE AC-22B PIFT2L331C401CCAE AC-22B PIFT3L331C601CCAE AC-23B PIFT0H331C151CCAE AC-23B PIFT1H331C251CCAE AC-23B PIFT2H331C401CCAE AC-23B PIFT3H331C601CCAE EATON CORPORATION CA008008EN

29 PIFT Plug in Fuse Terminal PIFT 4-pole Version Basic terminal without accessories Max. Size Breaking Type Article No. Pack Rated operating capacity designation (pcs.) current I e (A) SG AC-22B PIFT0L AC-22B PIFT1L AC-22B PIFT2L AC-22B PIFT3L AC-23B PIFT0H AC-23B PIFT1H AC-23B PIFT2H AC-23B PIFT3H Version Basic terminal 3 transformers; class 1; secondary current 1A Transformer wiring on plug-in terminal Plug-in terminal for auxiliary current wiring Auxiliary switch for switch-position indication NC+NO Max. Size Breaking Transformer Type Article No. Pack Rated operating capacity class Primary Secondary designation (pcs.) current Klasse current current I e (A) (A) (A) SG AC-22B PIFT0L431C151CCA AC-22B PIFT1L431C251CCA AC-22B PIFT2L431C401CCA AC-22B PIFT3L431C601CCA AC-23B PIFT0H431C151CCA AC-23B PIFT1H431C251CCA AC-23B PIFT2H431C401CCA AC-23B PIFT3H431C601CCA Version Basic terminal 1 current transformer; class 1; secondary current 1A Transformer wiring on plug-in terminal Plug-in terminal for auxiliary current wiring Auxiliary switch for switch-position indication NC+NO Electronic fuse monitoring Max. Size Breaking Transformer Type Article No. Pack Rated operating capacity class Primary Secondary designation (pcs.) current Klasse current current I e (A) (A) (A) SG AC-22B PIFT0L431C151CCAE AC-22B PIFT1L431C251CCAE AC-22B PIFT2L431C401CCAE AC-22B PIFT3L431C601CCAE AC-23B PIFT0H431C151CCAE AC-23B PIFT1H431C251CCAE AC-23B PIFT2H431C401CCAE AC-23B PIFT3H431C601CCAE EATON CORPORATION CA008008EN

30 PIFT Plug in Fuse Terminal Accessories Terminal guide-rails for installation of PIFT in xenergy Main Description Type Article No. Pack designation (pcs.) SG02811 Size 00 / Module height 50 mm (set of 2) ASPIFT00SG Size 1 / Module height 75 mm (set of 2) ASPIFT1SG Size 2-3 / Module height 150 mm (set of 2) ASPIFT23SG Cable separation for PIFT Description Type Article No. Pack designation (pcs.) SG02611 Size 00 (set of 3) ASPIFT00CS Size 1 (set of 3) ASPIFT1CS Size 2-3 (set of 3) ASPIFT23CS Safety shields for terminal guide-rails Description Type Article No. Pack designation (pcs.) SG02311 Set of 3 ASPIFTURP Connector strip Description Type Article No. Pack designation (pcs.) SG02111 Connector strip 16-pole ASPIFTUSC (terminal cross-section max. 2.5 mm 2 ) Switch-on lock Description Type Article No. Pack designation (pcs.) wa_sg03812 Size 00 / Module height 50 mm ASPIFT00CL Size 2-3 / Module height 150 mm ASPIFT23CL EATON CORPORATION CA008008EN

31 PIFT Plug in Fuse Terminal Accessories Pull-out tool Description Type Article No. Pack designation (pcs.) SG02211 For pulling out the PIFT ASPIFTUDT Transparent spare-space cover Description Type Article No. Pack designation (pcs.) wa_sg04012 Size 00 / Module height 50 mm ASPIFT00PC Size 1 / Module height 75 mm ASPIFT1PC Size 2-3 / Module height 150 mm ASPIFT23PC PIFT cover with switch-handle Description Type Article No. Pack designation (pcs.) SG03111 Size 00 / Module height 50 mm ASPIFT00SC Size 1 / Module height 75 mm ASPIFT1SC Size 2 / Module height 150 mm ASPIFT2SC Size 3 / Module height 150 mm ASPIFT3SC Auxiliary switch NC+NO Description Type Article No. Pack designation (pcs.) SG NO + 1 NC ASPIFTUAX EATON CORPORATION CA008008EN

32 PIFT Plug in Fuse Terminal Accessories Analog measuring device for horizontal application Size Transformer ratio Scale Type Article No. Pack (A) (A) designation (pcs.) SG N/1A 0-60/120 ASPIFT00CT1AM N/1A 0-150/300 ASPIFT00CT1AM N/1A 0-60/120 ASPIFTUCT1AM N/1A 0-75/150 ASPIFTUCT1AM N/1A 0-100/200 ASPIFTUCT1AM N/1A 0-150/300 ASPIFTUCT1AM N/1A 0-200/400 ASPIFTUCT1AM N/1A 0-250/500 ASPIFTUCT1AM N/1A 0-300/600 ASPIFTUCT1AM N/1A 0-400/800 ASPIFTUCT1AM N/1A 0-500/1000 ASPIFTUCT1AM N/1A 0-600/1200 ASPIFTUCT1AM N/5A 0-60/120 ASPIFT00CT5AM N/1A 0-75/150 ASPIFTUCT5AM N/5A 0-150/300 ASPIFT00CT5AM N/5A 0-60/120 ASPIFTUCT5AM N/5A 0-100/200 ASPIFTUCT5AM N/1A 0-150/300 ASPIFTUCT5AM N/5A 0-200/400 ASPIFTUCT5AM N/1A 0-250/500 ASPIFTUCT5AM N/5A 0-300/600 ASPIFTUCT5AM N/5A 0-400/800 ASPIFTUCT5AM N/1A 0-500/1000 ASPIFTUCT5AM N/5A 0-600/1200 ASPIFTUCT5AM Transformer class 1 Class Primary Secondary Rated power Type Article No. Pack current current (VA) designation (pcs.) (A) (A) SG ASPIFTUCTC ASPIFTUCTC ASPIFTUCTC ASPIFTUCTC ASPIFTUCTC ASPIFTUCTC ASPIFTUCTC ASPIFTUCTC ASPIFTUCTC ASPIFTUCTC ASPIFTUCTC ASPIFTUCTC ASPIFTUCTC ASPIFTUCTC ASPIFTUCTC ASPIFTUCTC ASPIFTUCTC ASPIFTUCTC EATON CORPORATION CA008008EN

33 PIFT Plug in Fuse Terminal Accessories Transformer class 0.5 Class Primary Secondary Rated power Type Article No. Pack current current (VA) designation (pcs.) (A) (A) SG ASPIFTUCTC ASPIFTUCTC ASPIFTUCTC ASPIFTUCTC ASPIFTUCTC ASPIFTUCTC ASPIFTUCTC ASPIFTUCTC ASPIFTUCTC ASPIFTUCTC ASPIFTUCTC ASPIFTUCTC ASPIFTUCTC ASPIFTUCTC ASPIFTUCTC ASPIFTUCTC EATON CORPORATION CA008008EN

34 PIFT Plug in Fuse Terminal Technical data Electrical properties PIFT00 PIFT1 PIFT2 PIFT3 Rated operational voltage U e V AC500 AC690 AC500 AC690 AC500 AC690 AC500 AC690 Rated operational current I e A Conventional free air thermal current I th A Rated frequency Hz Rated insulation voltage U i V AC1000 AC1000 AC1000 AC1000 AC1000 AC1000 AC1000 AC1000 Rated impulse withstand voltage U imp kv Operating cycles with current Total power loss at I th (without fuse) P v W Normal switching capacity Conditional rated short-circuit current 7) ka eff Utilization category AC-22B AC-22B AC-22B AC-22B AC-22B AC-22B AC-22B AC-22B Rated making capacity A Rated breaking capacity A High switching capacity Conditional rated short-circuit current 7) ka eff Utilization category AC-23B AC-23B AC-23B AC-23B AC-23B AC-23B AC-23B AC-23B Rated making capacity A Rated breaking capacity A Fuse links Size according to DIN Max. rated current (gl/gg) I N A Max. permissible power loss per fuse link P v W Mechanical properties Operating cycles without current Weight 1) kg Busbar distance mm Busbar thickness 3) mm Cable connection (flat connection) Bolt diameter M8 M8 M10 M10 M12 M12 M12 M12 Cable lug (DIN ) mm 2 1x ) 1x x x x x x x x x x x x x Flat bar mm 24x5 24x5 30x10 30x10 40x10 40x10 40x10 40x10 Tightening torque M a Nm Type of protection (front, device incorporated) In operation IP40 IP40 IP40 IP40 IP40 IP40 IP40 IP40 Operational state IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 Operating conditions Ambient temperature 2) T u C - 25 bis + 55 Rated operating mode Permanent operation Actuation Independent manual actuation Mounting position Horizontal 4), vertical 5) Altitude m Up to 2000 Pollution degree 3 Overvoltage category III 1) Without packaging, 3-pole 2) 35 C normal temperature, at 55 C with reduced operating current 3) Upright busbar 4) Cable connection right side 5) Cable connection bottom 6) Max. cable connection width 24mm 7) Distance to grounded parts 0mm 33 EATON CORPORATION CA008008EN

35 PIFT Plug in Fuse Terminal Dimensional drawings PIFT00 3-pole Tightening torque: 10 Nm Mas_PIFT00_3p PIFT1 3-pole Tightening torque: 15 Nm Mas_PIFT1_3p 34 EATON CORPORATION CA008008EN

36 PIFT Plug in Fuse Terminal Dimensional drawings PIFT2, PIFT3 3-pole Tightening torque: 30 Nm Mas_PIFT2_3_3p 35 EATON CORPORATION CA008008EN

37 PIFT Plug in Fuse Terminal Dimensional drawings PIFT00 4-pole Tightening torque: 10 Nm Mas_PIFT00_4p PIFT1 4-pole Tightening torque: 15 Nm Mas_PIFT1_4 36 EATON CORPORATION CA008008EN

38 PIFT Plug in Fuse Terminal Dimensional drawings PIFT2, PIFT3 4-pole Tightening torque: 30 Nm Mas_PIFT2_3_4p 37 EATON CORPORATION CA008008EN

39 PIFT Plug in Fuse Terminal Dimensional drawings - Accessories Terminal guide-rail ASPIFT00SG Terminal guide-rail ASPIFT1SG Mas_ASPIFT00SG Mas_ASPIFT1SG Terminal guide-rail ASPIFT23SG Cable separation ASPIFT00CS Mas_ASPIFT23SG Mas_ASPIFT00CS Cable separation ASPIFT1CS Cable separation ASPIFT23CS Mas_ASPIFT1CS Mas_ASPIFT23CS 38 EATON CORPORATION CA008008EN

40 PIFT Plug in Fuse Terminal Dimensional drawings - Accessories Safety shield for terminal guide-rail ASPIFTURP Connector strip ASPIFTUSC Mas_ASPIFTURP Mas_ASPIFTUSC Switch-on lock ASPIFT00CL Switch-on lock ASPIFT23CL Mas_ASPIFT00CL Mas_ASPIFT23CL Pull-out tool ASPIFTUDT Spare-space cover ASPIFT00PC, ASPIFT1PC, ASPIFT23PC Type A ASPIFT00PC 49.5 ASPIFT1PC 74.5 ASPIFT23PC Mas_ASPIFTUDT Mas_ASPIFT00PC 39 EATON CORPORATION CA008008EN

41 PIFT Plug in Fuse Terminal Dimensional drawings - Accessories Cover with switch-handle ASPIFT00SC Cover with switch-handle ASPIFT1SC Mas_ASPIFT00SC Mas_ASPIFT1SC Cover with switch-handle ASPIFT2SC, ASPIFT3SC Auxiliary switch ASPIFTUAX Mas_ASPIFT2SC Mas_ASPIFTUAX Analog measuring device ASPIFT00CT Analog measuring device ASPIFTUCT Mas_ASPIFT00CT Mas_ASPIFTUCT 40 EATON CORPORATION CA008008EN

42 PIFT Plug in Fuse Terminal Dimensional drawings - Accessories Current transformer ASPIFTUCTC Mas_ASPIFTUCTC 41 EATON CORPORATION CA008008EN

43 Fuse Devices Fuse Devices SG09610 Fuse Devices - Series FCF vt40815 Fuse Devices - Series NH-SLS and NHW-SLS 42 EATON CORPORATION CA008008EN

44 Fuse Devices - Series FCF NH NH In-line Fuse Switch Disconnectors, 3 poles, FCFSDNH Incl. cover for connection area Mounting without the need of drilling (Accessories) Connection either at the top or at the bottom Max. Rated Max. Size Type Article No. Pack Operational Fuse-link designation (pcs.) Current 500V 690V I e (A) (A) (A) SG09310 Center-to-center distance of 100 mm between the phases - size FCFSDNH00BB Center-to-center distance of 100 mm between the phases - size 00 - for installing current transformers Equipped with spacer pins for retro-fitting of current transformers if ever the need should araise FCFSDNH00BB100-CTO SG09410 Center-to-center distance of 185 mm between the phases - size 1 to size FCFSDNH1BB FCFSDNH2BB FCFSDNH3BB Center-to-center distance of 185 mm between the phases - size 1 to size 3 - for installing current transformers Equipped with spacer pins for retro-fitting of current transformers if ever the need should araise FCFSDNH1BB185-CTO FCFSDNH2BB185-CTO FCFSDNH3BB185-CTO EATON CORPORATION CA008008EN

45 Fuse Devices - Series FCF NH Accessories for NH In-line Fuse Switch Disconnectors Series FCF Double adapter to adjust the center-to-center distance between the phases from 100 to 185 mm Description Type Article No. Pack designation (pcs.) SG10010 Adapater for fixing two strips of size 00 ASNH100BABB on a busbar of 185 mm Adapter clip to adjust the center-to-center distance between the phases from 100 to 185 mm Description Type Article No. Pack designation (pcs.) SG10910 Clip for fixing one stip of size 00 ASNH100ACBB on a busbar of 185 mm Busbar Terminal Size 00 Description Type Article No. Pack designation (pcs.) SG10610 For mounting the NH in-line fuse switch disconnector ASNH100CT without the need of drilling Size 00 for a busbar thickness of 5-10 mm Compensation Cover Description Type Article No. Pack designation (pcs.) SG09710 For height adjustment of a size 00 strip to a ASNH185CP strip of size 1 to size 3 Prism Terminal Description Type Article No. Pack designation (pcs.) SG11110 ASPT Connection Set Description Type Article No. Pack designation (pcs.) SG11210 Set for 2 cable lugs suitable for a strip of ASNH mm size EATON CORPORATION CA008008EN

46 Fuse Devices - Series FCF NH Cover for connection areas Description Type Article No. Pack designation (pcs.) SG63212 Cover for connection area, size 1-3 ASNH185CP Connection Assembly Kit - consisting of 3 different items For parallel switching of 2 strips of size 2 or 3 Description Type Article No. Pack designation (pcs.) SG11010 Handle connection ASNH185HCK SG10710 Busbar kit ASNH185RK SG09910 Cover for connection area ASNH185CP Current transformer for 100 mm center-to-center distance between the phases Transformation G Class Rated Apparent Power Type Article No. Pack (A) (VA) designation (pcs.) SG / ASCNH100CT / ASCNH100CT / ASCNH100CT / ASCNH100CT Current transformer for 185 mm center-to-center distance between the phases Transformation G Class Rated Apparent Power Type Article No. Pack (A) (VA) designation (pcs.) SG / ASCNH185CT / ASCNH185CT / ASCNH185CT / ASCNH185CT / ASCNH185CT / ASCNH185CT / ASCNH185CT / ASCNH185CT / ASCNH185CT /5 1 5 ASCNH185CT /5 1 5 ASCNH185CT /5 1 5 ASCNH185CT EATON CORPORATION CA008008EN

47 Fuse Devices - Series FCF NH NH In-line Fuse Switch Disconnectors, 3 poles, FCFSDNH00BB Center-to-center distance of 100 mm between the phases Size 00 Technical Data Electrical For LV HRC fuse-links acc. to DIN VDE Size 000/00 Rated operating voltage U e V AC 690 Rated operating current I 1) e A 160 Conv. free air thermal current I th with fuse-links 1) A 160 Conv. free air thermal current I th with solid-links 1) A 210 Rated frequency Hz Rated insulation voltage U i V AC 800 Total power loss at I th (without fuse-links) P v W 18 Rated impuls withstand voltage U imp kv 8 Utilization category (AC-22B) 400 V A V A V A 100 Conditional rated short-circuit current 2) ka 80 Rated short-time withstand current I cw ka Max. permissible power loss P a per fuse-link W 12 FCFSDNH00BB100(-CTO) Mechanical Flat terminal Bolt diameter M8 Cable lug (DIN 46235) mm 2 1 x (max. 25 mm width) Flat bar mm 20 x 10 Tightening torque M a Nm Terminal Terminal capacity mm 2 round 1,5-70 Cu / flat 6 x 9 x 0,8 Tightening torque M a Nm 2,6 Degree of protection, front side, device fitted Operating condition IP30 Switching element open IP10 Ambient temperature T 3) amb C -25 up to +55 Rated operating mode uninterrupted duty Actuation dependent manual operation Mounting position vertical, horizontal Altitude m up to 2000 Pollution degree 3 Overvoltage category III 1) In case of mounting several units in low voltage switchgear-combinations, please consider rated diversity factors acc. to EN ) Type-tested with LV-HRC-fuse-links characteristic gg. 3) 35 C Normal temperature, at 55 C with reduced operating current. 46 EATON CORPORATION CA008008EN

48 Fuse Devices - Series FCF NH Dimensions (mm) NH In-line Fuse Switch Disconnectors, 3 poles, center-to-center distance of 100 mm between the phases, size 00 FCFSDNH00BB100 Outgoers at the top Outgoers at the bottom FCFSDNH00BB100-CTO Outgoers at the top Installation of a transformer is possible at the bottom Installation of a 3-pole or 1-pole transformer is possible Outgoers at the bottom 47 EATON CORPORATION CA008008EN

49 Fuse Devices - Series FCF NH NH In-line Fuse Switch Disconnectors, 3 poles, FCFSDNH.BB Center-to-center distance of 185 mm between the phases Sizes 1, 2, 3 Technical Data FCFSDNH1BB185(-CTO) FCFSDNH2BB185(-CTO) FCFSDNH3BB185(-CTO) Electrical For LV HRC fuse-links acc. to DIN VDE Size Rated operating voltage U e V AC Rated operating current I 1) e A Conv. free air thermal current I th with fuse-links 1) A Conv. free air thermal current I th with solid-links 1) A Rated frequency Hz Rated insulation voltage U i V AC Total power loss at I th (without fuse-links) P v W Rated impulse withstand voltage U imp kv Utilization category 400 V A 250 (AC-23B) 400 (AC-23B) 630 (AC-22B) 500 V A 250 (AC-22B) 400 (AC-22B) 630 (AC-22B) 690 V A 250 (AC-22B) 400 (AC-22B) 630 (AC-21B) Conditional rated short-circuit current 2) ka a) Rated short-time withstand current I cw ka 14,5 14,5 14,5 Max. permissible power loss P a per fuse-link W Mechanical Flat terminal Bolt diameter M10 M12 M12 Cable lug (DIN 46235) mm 2 1 x x x (max 43mm width) Flat bar mm 30 x x x 10 Tightening torque M a Nm Degree of protection, front side, device fitted Operating condition IP30 IP30 IP30 Switching element open IP10 IP10 IP10 Ambient temperature T 3) amb C -25 up to up to up to +55 Rated operating mode uninterrupted duty uninterrupted duty uninterrupted duty Actuation dependent manual operation dependent manual operation dependent manual operation Mounting position vertical, horizontal vertical, horizontal vertical, horizontal Altitude m up to 2000 up to 2000 up to 2000 Pollution degree Overvoltage category IV IV IV 1) In case of mounting several units in low voltage switchgear-combinations, please consider rated diversity factors acc. to EN ) Type-tested at AC 725 V with LV-HRC-fuse-links characteristic gg. 3) 35 C Normal temperature, at 55 C with reduced operating current. 48 EATON CORPORATION CA008008EN

50 Fuse Devices - Series FCF NH Dimensions (mm) NH In-line Fuse Switch Disconnectors, 3 poles, center-to-center distance of 185 mm between the phases, size 1 - size 3 FCFSDNH1BB185 Connection at the bottom (Au) Connection at the top (Ao) FCFSDNH2BB185, FCFSDNH3BB185 Connection at the bottom (Au) Connection at the top (Ao) 49 EATON CORPORATION CA008008EN

51 Fuse Devices - Series FCF NH Dimensions (mm) NH In-line Fuse Switch Disconnectors, 3 poles, center-to-center distance of 185 mm between the phases, size 1 - size 3, for installing transformers FCFSDNH1BB185-CTO Connection at the bottom (Au) Connection at the top (Ao) Installation of a 3-pole or 1-pole transformer is possible FCFSDNH2BB185-CTO, FCFSDNH3BB185-CTO Connection at the bottom (Au) Connection at the top (Ao) Installation of a 3-pole or 1-pole transformer is possible 50 EATON CORPORATION CA008008EN

52 Fuse Devices - Series FCF NH Dimensions (mm) - Accessories Double Adapter ASNH100BABB100 Adapter Clips ASNH100ACBB100 Busbar Terminal Size 00 ASNH100CT For mounting without the need of drilling, for a busbar thickness of 5-10 mm Tightening torque = 6 Nm Compensation Cover ASNH185CP100 Handle Connection ASNH185HCK Busbar Kit ASNH185RK Cover for Connection Area ASNH185CP 51 EATON CORPORATION CA008008EN

53 Fuse Devices - Series FCF NH Dimensions (mm) - Accessories Cover for Connection Area ASNH185CP EATON CORPORATION CA008008EN

54 Fuse Devices - Series NH-SLS and NHW-SLS NH Vertical Fuse Switch Disconnectors, 3-pole, 60 mm Center-to-Center Distance between Phases, NH-SLS Cover for connection area is included To be mounted with snap-on mechanism Connection at the top or bottom Scope of delivery of NH-SLS size 00: with a set of clips/screws for connecting Busbar mounting of NH-SLS size 00: 60 mm center-to-center distance between the bars, to be mounted with snap-on mechanism Delivery includes connecting screw and box terminal Max. Max. Size Use Type Article No. Pack Rated oper. fuse link designation (pcs.) current 400V 690V I e (A) (A) (A) SG46912 Without fuse monitoring x5/10 NH-SLS-00/ /182 15x5/10 20x5/10 25x5/10 30x5/10 Double T-profile Triple T-profile SG46912 With fuse monitoring x5/10 NH-SLS-00/ SI /112 15x5/10 20x5/10 25x5/10 30x5/10 Double T-profile Triple T-profile NH Vertical Fuse Switch Disconnectors, 3-pole, 100 mm Center-to-Center Distance betw. Phases, NH-SLS Cover for connection area is included M8 connection screw and clip-terminals are included Screwless or drill-free mounting with claw-type terminals In combination with fuse strips of sizes 1/2/3 NO mounting on a 185 mm busbar system possible (as there is no height compensation possible) Connection at the top or bottom Max. Max. Size Use Type Article No. Pack Rated oper. fuse link designation (pcs.) current 500V 690V I e (A) (A) (A) SG46912 Without fuse monitoring Z-NH-SLS-00- NH-SLS-00/ /182 SAD... SG46912 With fuse monitoring Z-NH-SLS-00- NH-SLS-00/160-SI /112 SAD EATON CORPORATION CA008008EN

55 Fuse Devices - Series NH-SLS and NHW-SLS NH Vertical Fuse Switch Disconnectors, 3-pole, 185 mm Center-to-Center Distance betw. Phases, NHW-SLS With integrated cover for the connection area (additional cover for cable area is possible) Drill-free mounting using claw-type terminals for size 00 (Z-NHW-SLS-00-BBC, Article No ) Drill-free mounting using claw-type terminals for sizes 1,2,3 (Z-NHW-SLS-00-BBC, Article No ) Self-closing test holes integrated in the cover High version for size 00 = suitable for mounting a current transformer Flat version for size 00 = NO direct mounting of a current transformer possible, height compensation to construction depth for sizes 1,2,3 via an adapter (NHW-SLS /185-SADD, Article No ), mounting a current transformer is possible if an adapter is used Connection at the top or bottom Max. Max. Size Notes Type Article No. Pack Rated oper. fuse link designation (pcs.) current 500V 690V I e (A) (A) (A) VT40815 Without fuse monitoring high NHW-SLS-00/H version flat NHW-SLS-00/F version NHW-SLS NHW-SLS NHW-SLS VT40515 With fuse monitoring high NHW-SLS-00/H/SI version flat NHW-SLS-00/F/SI version NHW-SLS-1/SI NHW-SLS-2/SI NHW-SLS-3/SI EATON CORPORATION CA008008EN

56 Fuse Devices - Series NH-SLS and NHW-SLS Accessories for NH Vertical Fuse Switch Disconnectors of the NH-SLS and NHW-SLS Series Bar adapter - depth compensation (185/185) Adapter + NHW-SLS-00/F = same construction depth as NHW-SLS-1,2,3 Description Type Article No. Pack designation (pcs.) VT41515 Double adapter 185/185 - flat version Z-NHW-SLS /185-SADD Claw-type terminals for size 00 (185mm) Screwless fixing of size 00 fuse strips, 185 mm center-to-center distance between phases Can be used for Type Article No. Pack designation (pcs.) VT42415 NHW-SLS-00/F+H Z-NHW-SLS-00-BBC Claw-type terminals for sizes 1,2,3 (185mm) Screwless fixing of size 1/2/3 fuse strips Can be used for Type Article No. Pack designation (pcs.) VT42315 NHW-SLS Z-NHW-SLS BBC Cover for connection area, 60/100 mm center-to-center distance between phases wa_sg01712 Can be used for Type Article No. Pack designation (pcs.) Size 00 NH-SLS-00/160 Z-NH-SLS-KA EATON CORPORATION CA008008EN

57 Fuse Devices - Series NH-SLS and NHW-SLS Cover for connection area, 185 mm center-to-center distance between phases VT42015 Can be used for Type Article No. Pack designation (pcs.) Size 00 flat/bottom, NHW-SLS-00/F Z-NHW-SLS-00-TC/F/D flat/top, NHW-SLS-00/F Z-NHW-SLS-00-TC/F/U high/bottom, NHW-SLS-00/H Z-NHW-SLS-00-TC/H/D high/top, NHW-SLS-00/H Z-NHW-SLS-00-TC/H/U Sizes 1/2/3 NHW-SLS-1,2,3 Z-NHW-SLS Box terminal Suitable for fuse strips of sizes 1/2/3 Can be used for Terminal capacity Type Article No. Pack designation (pcs.) VT42615 NHW-SLS-1, 2, 3 1x50-185mm 2 rm Cu/Al Z-NHW-SLS-1+2-VT x70-240mm 2 sm/se Cu/Al NHW-SLS-1,2,3 1x mm 2 sm Cu/Al Z-NHW-SLS-3-VT x mm 2 se Cu/Al 1x mm 2 rm Cu/Al Quick connector Suitable for size 00 fuse strips, 60 and 100mm center-to-center distance between phases Can be used for Type Article No. Pack designation (pcs.) VT42815 Size 00 Z-NHW-00-BK Screw (M8) universal M8 Can be used for Type Article No. Pack designation (pcs.) VT42715 Size 00 Z-NHW-SCREW-M EATON CORPORATION CA008008EN

58 Fuse Devices - Series NH-SLS and NHW-SLS Current transformer suitable for NHW-SLS-00, 1, 2, 3 For size 00 use the high version of the strips (NHW-SLS-00/H) No additional space required, can be installed in the standard strip Claw-type mounting is still possible Transformer conductors to be fixed with Z-NH-SLS BC fixing clips VT42215 Transformation G Class Rated Apparent Power Type Article No. Pack (VA) designation (pcs.) Suitable for size 00 80/5 1 5 Z-NHW-CT-80/ /5 1 5 Z-NHW-CT-150/ VT42115 Suitable for sizes 1,2,3 and for adapter Z-NHW-SLS /185-SADD 150/ Z-NHW-CT-150/ / Z-NHW-CT-200/ / Z-NHW-CT-250/ / Z-NHW-CT-400/ / Z-NHW-CT-600/ Fixing clip For current transformer on busbar adapter in the 185mm busbar system (size 00) Type Article No. Pack designation (pcs.) wa_sg06606 Z-NH-SLS-00-BC Connection strap with brace terminal Universal use Direct mounting on Cu rails Not suitable for fuse strips of the NHW-SLS series Drill hole for connection screw Ø 13 in the connection strap For cross sections of mm 2 Type Article No. Pack designation (pcs.) vt57115 Z-NHW-SPK EATON CORPORATION CA008008EN

59 Fuse Devices - Series NH-SLS and NHW-SLS NH Vertical Fuse Switch Disconnectors, 3-pole, 60 and 100mm Center-to-Center Distance betw. Phases, NHW-SLS Technical Data Version in accordance with IEC : A1: 2010, IEC : A1: pole switching Connection at the top and bottom Arc quenching device For NH fuse links according to IEC size NH00 Contact protection even with open switch covers and in parking position Mechanical interlock of fuse links Degree of protection (front side), Degree of protection in the connection area depends on the installation position IP30 Connection contacts - Screw M8, clip 2xM5, clear diameter 12mm - Prismatic terminal connection Cu, Al * 16-70mm 2 rm, sm, f+ae * Connections to aluminium conductors are not maintenance-free For 60mm center-to-center distance between bars screwless busbar contacting For 100 mm center-to-center distance between bars - for screw-fixing on busbars with drill holes, screw M8 - drill-free mounting with clamping bracket Version 3-pole switching Type of current AC (50-60 Hz) Rated operating voltage U e ** V AC 690 Rated insulation voltage U i ** V 1000 Rated impulse withstand voltage U imp without fuse monitoring ** kv 8 Rated operating current I e * A 160 Utilization categories without fuse monitoring ** AC22B (690 V) AC23B (400 V) AC23B (500 V 125 A) Conditional rated short-circuit current *** ka 50 For NH fuse links acc. to IEC with power loss per phase up to W 12 Indicator switch for displaying the cover position: 2 switches (change-over) can be used Rated operating voltage V AC 250 V DC 30 Rated operating current A AC 5 A DC 4 Electronic fuse monitoring: 2 LED indicators Memory functions and remote reset can be programmed 2 changers 2x Cu 2.5 mm 2 massive, DIN or 2x Cu1.5 mm 2 litz wire with ferrule, DIN /-2 /-3 Internal resistance of measurement paths within MOhm range, VDE regulations regarding contact voltage (> 1000 Ohm/V) are complied with For disconnecting switch off the upstream main switch * For permanent simultaneous operation of several devices please respect the rated load factor acc. to IEC/EN , table 101. With AC23B please make sure a distance of 50 mm at the top and 25 mm at the side is guaranteed with regard to grounded components. ** Fuse monitoring U e, U i 400 V AC, U imp 4 kv, VG2 (mains connections) *** Type-tested with fuse links of operating class gl/gg 58 EATON CORPORATION CA008008EN

60 Fuse Devices - Series NH-SLS and NHW-SLS NH Vertical Fuse Switch Disconnectors, 3-pole, 185mm Center-to-Center Distance betw. Phases, NHW-SLS Technical Data Version in accordance with IEC : A1: 2010, IEC : A1: and 3-pole switching For NH fuse links according to IEC size NH00, 1, 2, 3 Can be mounted on a 185mm system by screw-fixing on busbars with drill holes Screw M8 for size 00, Screw M12 for sizes 1, 2, 3 Optionally drill-free with a clamping bracket for busbars (10 mm thick) and profile rails Cable connections at the top and bottom by turning the bottom part of the strip Contact protection and switch-on aids Contact protection even with open switch covers and in parking position Mechanical interlocking of fuse links in switch covers Degree of protection (front side), Degree of protection in the connection area depends on the installation position IP20 Test holes in the switch covers are self-closing Cover of connection area (Accessories) for lateral contact protection Conductor connections: Size Screw-type Direct connection Box terminal Clip or prismatic Clip/Prismatic connection terminals connection connection Cu and Al* terminal area for flat Cu conductor 00 M8-1x1.5-70mm 2 1x10-70mm 2 12x(1-10)mm 70mm 2 ** rm, sm, f, f+ae 1x95mm 2 rm, sm, f 1, 2 M12 1x35-150mm 2 sm Cu/Al - - 2x185mm 2-1x50-185mm 2 se 1x50-185mm 2 rm 240mm 2 1x35-70mm 2 rm 1x70-240mm 2 sm/se 1x50mm 2 re Md 32-40Nm 2x35-150mm 2 sm 2x50-185mm 2 se 2x35-70mm 2 rm 2x35-50mm 2 re Md Nm 3 M12 1x35-150mm 2 sm Cu/Al - - 2x185mm 2-1x50-185mm 2 se 1x mm 2 sm 240mm 2 1x35-70mm 2 rm 1x mm 2 se 1x50mm 2 re 1x mm 2 rm Md 32-40Nm 2x35-150mm 2 sm 2x50-185mm 2 se 2x35-70mm 2 rm 2x35-50mm 2 re Md Nm * Connections to aluminium conductors are not maintenance-free ** Copper conductors for relevant rated currents according to IEC/EN Size Type of current AC (50 Hz) AC (50 Hz) AC (50 Hz) AC (50 Hz) Rated operating voltage U e ** 690 V AC 690 V AC 690 V AC 690 V AC Rated insulation voltage U i ** 1000 V 1000 V 1000 V 1000 V Rated peak withstand voltage U imp without fuse monitoring ** 8 kv 8 kv 8 kv 8 kv Utilization categories without fuse monitoring ** AC22B AC23B AC23B AC23B (160A/500V) (250A/400V) (400A/400V) (630A/400V) AC23B AC22B AC22B AC22B (160A/400V) (250A/690V) (400A/690V) (630A/400V) AC21B AC21B AC21B (250A/690V) (400A/690V) (630A/400V) Conditional rated short-circuit current, 3-pole switching *** 100kA/500V 80kA/500V 80kA/500V 80kA/500V 100kA/690V 80kA/690V 80kA/690V 80kA/690V Conditional rated short-circuit current, 1-pole switching *** 100kA/500V 80kA/500V 80kA/500V 80kA/500V 100kA/690V 80kA/690V 80kA/690V 80kA/690V For NH fuse links acc. to IEC **** with power loss per phase up to 12W 23W 34W 48W 59 EATON CORPORATION CA008008EN

61 Fuse Devices - Series NH-SLS and NHW-SLS NH Vertical Fuse Switch Disconnectors, 3-pole, 185mm Center-to Center Distance betw. Phases, NH-SLS Technical Data (continued) Size 3 as double NH vertical fuse disconnector 1250A: 3-pole, 690 V AC, 2x630A, 3-pole switching, conditional rated short-circuit current up to 80kA With fuses gl/gg, utilization categories AC20B (690V) Indicator switch for displaying the cover position: 3 switches (change-over) can be used for sizes 00, 1, 2, 3 Rated operating voltage V AC 250 V DC 30 Rated operating current A AC 5 A DC 4 Electronic fuse monitoring: 2 LED indicators Memory functions and remote reset can be programmed 2 x change-over 2x Cu 2.5 mm 2 massive, DIN or 2x Cu1.5 mm 2 litz wire with ferrule, DIN /-2 /-3 Internal resistance of measurement paths within MOhm range, VDE regulations regarding contact voltage (> 1000 Ohm/V) are complied with For disconnecting switch off the upstream main switch * For permanent simultaneous operation of several devices please respect the rated load factor acc. to IEC/EN , table 101. Please make sure a distance of 50 mm at the top and 25 mm at the side is guaranteed with regard to grounded components. ** Fuse monitoring U e, U i 400 V AC, U imp 4 kv, VG2 (mains connections) *** Type-tested with fuse links of operating class gl/gg **** NH fuse links of size 1 can be used in NHW-SLS of size 2 60 EATON CORPORATION CA008008EN

62 Fuse Devices - Series NH-SLS and NHW-SLS Dimensions (mm) NH Vertical Fuse Switch Disconnector NHW-SLS-00/H High version - Same height as sizes 1, 2, 3 - Installation of a transformer is possible! max NH Vertical Fuse Switch Disconnector NHW-SLS-00/H/SI Incl. fuse monitoring - high version - Same height as sizes 1, 2, 3 - Installation of a transformer is possible! EATON CORPORATION CA008008EN

63 Fuse Devices - Series NH-SLS and NHW-SLS Dimensions (mm) NH Vertical Fuse Switch Disconnector NHW-SLS-00/F Flat version - In order to reach the same depth as with sizes 1, 2, 3 you need to use an additional adapter (NHW-SLS /185-SADD_179764) - Installation of a transformer is only possible if you use a device adapter max NH Vertical Fuse Switch Disconnector NHW-SLS-00/F/SI Incl. fuse monitoring - flat version - In order to reach the same depth as with sizes 1, 2, 3 you need to use an additional adapter (NHW-SLS /185-SADD_179764) - Installation of a transformer is only possible if you use a device adapter EATON CORPORATION CA008008EN

64 + + + max max. Fuse Devices - Series NH-SLS and NHW-SLS Dimensions (mm) Cable connection for size 00 flat and high version: SW 13 SW 4 M8, 8-10 Nm Ib.in M6, 5-6 Nm Ib.in 1,5-70 mm² <12 mm max. Kabelschuh Cable lugs DIN mm² DIN mm² 3.3A 20 mm 3.3B SW 4 M5, 3-4 Nm Ib.in 1 clic mm² rm, sm,f, f+ae mm² 70 mm² rm, sm,f, f+ae 95 mm² rm, sm, f 3.3C EATON CORPORATION CA008008EN

65 Fuse Devices - Series NH-SLS and NHW-SLS Dimensions (mm) NH Vertical Fuse Switch Disconnector NHW-SLS-1/2/ max Cable connection NHW-SLS-1/2/3 64 EATON CORPORATION CA008008EN

66 Fuse Devices - Series NH-SLS and NHW-SLS Dimensions (mm) NH Vertical Fuse Switch Disconnector NHW-SLS-1/2/3-SI With fuse monitoring Cable connection NHW-SLS-1/2/3-SI With fuse monitoring 65 EATON CORPORATION CA008008EN

67 Fuse Devices - Series NH-SLS and NHW-SLS Dimensions (mm) - Accessories Double adapter Z-NHW-SLS /185-SADD W x H x D: 83 x 450 x 50 Weight: 55 kg/ Claw-type terminals for size 00 Claw-type terminals for sizes 1, 2, EATON CORPORATION CA008008EN

68 Accessories for Panel Building - Connection Terminals K-Type Connection Terminals 4300PIC-326 Add-on terminals 1-, 3-, 4-, 5-pole Round conductors - sector conductors - flat conductors A Conversion sets Connections for auxiliary conductors 4300PIC-308 Terminal covers 4300PIC PIC EATON CORPORATION CA008008EN

69 Accessories for Panel Building - Connection Terminals K-Type Terminals External connection for round or sector conductors, other end for Cu band. Suitable for copper and aluminium conductors Adapter for band connection to cable connection U, V, W X, Y, Z L1, L2, L3 T1, T2, T3 PE, N, PEN. U i = 1000 V AC Incl. terminal labels Poles Terminal Capacities 1) Terminal Capacities 1) Type Article No. Pack Cu Al Cu Band Cu Bar designation (pcs.) Al n mm 2 mm 2 mm mm 4300PIC PIC-327 Rated Operating Current Ie 160 A 1 1x x35-70 (1x) 3x9x0.8 18x4 K95/1N up to K95/ (1x) 6x9x0.8 K95/ K95/ K95/1N/BR PIC PIC-321 Rated Operating Current Ie 250 A 1 1x x (1x) 4x16x0.8 18x4 K150/1N or or up to K150/ x x35-50 (2x) 6x16x0.8 K150/ K150/ K150/1/BR PIC PIC-310 Rated Operating Current Ie 400 A 1 1x x (1x) 6x16x0.8 25x15 K240/1N or or up to K240/ x x50-95 (1x) 10x16x0.8 K240/ K240/ K240/1/BR PIC PIC-304 Rated Operating Current Ie 630 A 1 1x x (1x) 10x16x0.8 40x15 K2X240/1N or or up to K2X240/ x x (2x) 11x21x1 K2X240/ K2X240/ K2X240/1/BR PIC PIC-299 Rated Operating Current Ie 800 A 1 2x x (2x) 11x21x1 50x20 K3X185/ or or K3X185/ x x K3X185/ K3X185/ PIC PIC-294 Rated Operating Current Ie 1000 A 1 2x x (2x) 11x21x1 60x15 K3X240/ or or or K3X240/ x x x40x1 K3X240/ or K3X240/ x50x1 1 2x x (2x) 11x21x1 60x15 K4X185/ or or or K4X185/ x x x40x1 K4X185/ or K4X185/ x50x1 1) Key Round cable, single-wired Round cable, multi-wired Sector cable, single-wired Sector cable, multi-wired Cu band Cu bar Type K95/1N/BR, K150/1/BR, K240/1/BR and K2X240/1/BR = for round cable or sector cable connection on both sides 68 EATON CORPORATION CA008008EN

70 Accessories for Panel Building - Connection Terminals Accessories, Terminal Cover 5-pole Terminal Cover Incl. warning sign According to DIN (electricity lightning bolt) 3 or 4-pole terminal covers can be obtained by splitting wa_vt23613 Suitable for Type Article No. Pack designation (pcs.) 3, 4 and 5-poles respectively K95/... H-K95/ K150/... H-K150/ K240/... H-K240/ K2X240/... H-K2X240/ K3X185/... H-K3X185/ K3X240/... H-K3X240/ K4X185/... H-K4X185/ , 4, 5-pole Finger Protection IP2X for 3, 4, 5-pole K-Terminals Degree of protection IP2X only in connection with terminal cover H-K... vt57915 Suitable for Type Article No. Pack designation (pcs.) 3, 4 and 5-poles respectively K95/... K95-IPK K150/... K150-IPK K240/... K240-IPK K2X240/... K2X240-IPK Conversion Sets for K-Type Terminals For one conductor For conversion from band-type connection to cable-type connection Suitable for Rated Permanent Type Article No. Pack Current I u (A) designation (pcs.) VT10408 K95/ D-K K150/ D-K K240/ D-K K2X240/ D-K2X K3X185/ D-K3X K3X240/ D-K3X K4X185/ D-K4X For one auxiliary conductor M4-screw with pressure shim Terminal capacity 0,5-2,5 mm 2 Suitable for Type Article No. Pack designation (pcs.) VT12508 K95/... + K150/... HK-K95-K K240/... HK-K K2X240/... HK-K2X K3X185/... HK-K3X K3X240/... HK-K3X K3X240/... + K4X185/... HK-K3X240-K4X EATON CORPORATION CA008008EN

71 Accessories for Panel Building - Connection Terminals Accessories, Terminal Cover Insulated Individual Terminals Finger-proof on all sides, VDE approved For snap-fitting on top-hat rail to IEC/EN Can be screwed onto mounting plates and directly on CI enclosure stacking mandrels Can be grouped with additional K50/1 terminals With L, N, and protective conductor markings Circuit Rated Permanent Terminal Capacities 1) Type Article No. Pack Current I u Cu Band designation (pcs.) A mm 2 mm 4300PIC x 9 x 0.8 K50/ ) Round cable, single-wired Round cable, finely-wired with end sleeve professionally pressed Round cable, multi-wired Sector cable, single-wired Sector cable, multi-wired Cu band Cu bar 70 EATON CORPORATION CA008008EN

72 Accessories for Panel Building - Connection Terminals K-Type Terminals Type a a1 a2 a3 b b1 c a5 I K95/1N 37-18, K95/ K95/ K95/ K150/1N 37-18, K150/ K150/ K150/ K240/1N K240/ K240/ K240/ , K2X240/1N K2X240/ , K2X240/ K2X240/ K3X185/ K3X185/ K3X185/ , K3X185/ K3X240/ K3X240/ K3X240/ K3X240/ , K4X185/ K4X185/ K4X185/ K4X185/ , Insulated Individual K50/1 Terminal Standards: VDE approval in acc. The product complies with with DIN EN the EC's RoHS Directives Color: RAL 7035 light grey Materials: Terminal body: Brass (CuZn39Pb2) blank Housing: PA 6 (halogen-free) Screws: Steel Zn, thick-film passivated Flame-retardant: self-extinguishing Mechanical values: Stripping lengths: 50 mm 2 16 mm Screw heads: Hexagon socket-head screw: 5 mm Dimensions: w h d (mm): 24.8 x 40.5 x PIC PIC PIC PIC-286 Electrical values: Rated uninterrupted current: 150 A Rated operational voltage: 690 V Terminal capacities: 2x 50 mm2 2 Cu round conductor, solid Cu round conductor, stranded mm 2 Cu round conductor, flexible with ferrule mm 2 Cu ribbon cable 3 x 9 x 0.8 mm For use with: CI, CI-K, cam switches T, switch-disconnectors P, circuit-breakers NZM; CU-BAND3X9x0.8-BK 71 EATON CORPORATION CA008008EN

73 Accessories for Panel Building - Filters and Fans Filter-based Fans, Filter Pads and Air Exit Filters wa_vt01814 UL, cul approval Degree of protection IP54 and IP55 Rated voltage 230V Fixing without any screws Fast changing of filter pads wa_vt02314 Thermoplastic material RAL 7035 High class floating or ball bearing Self-extinguishing UL94 V0 Simple change of air boost direction 4 corner arrester Variable connection per twisting of 90 Temperature range -40 C C 72 EATON CORPORATION CA008008EN

74 Accessories for Panel Building - Filters and Fans Filter-based fan IP54 Degree of protection IP54 Rated voltage 230V / 50Hz Simple change of air boost direction 4 corner arrester Variable connection per twisting of 90 RAL 7035 High class floating or ball bearing Self-extinguishing UL94 V0 Back-up fuse 6A Dimensions Cut-out HxW Air flow Type Article No. Pack [mm] [mm] free blowing designation (pcs.) [m 3/ h] wa_vt x109 92x92 25/29 E-FAN x x125 61/70 E-FAN x x /125 E-FAN x x /171 E-FAN x x /292 E-FAN Air exit filter IP54 Degree of protection IP54 Same design as filter-based fan Fixing in the door or in the side wall without any screws Easy change of filter pads during operation With integrated foam sealing towards the electrical cabinet Cut-out HxW Type Article No. Pack [mm] designation (pcs.) wa_vt x92 EX-FILT x125 EX-FILT x177 EX-FILT x223 EX-FILT EATON CORPORATION CA008008EN

75 Accessories for Panel Building - Filters and Fans Filter-based fan IP55 Degree of protection IP55 UV resistant plastic enclosure Rated voltage 230V / 50Hz Simple change of air boost direction 4 corner arrester Variable connection per twisting of 90 RAL 7035 High class floating or ball bearing Self-extinguishing UL94 V0 Back-up fuse 6A Dimensions Cut-out HxW Air flow Type Article No. Pack [mm] [mm] free blowing designation (pcs.) [m 3/ h] wa_vt x x125 56/64 E-FAN x x /110 E-FAN x x /160 E-FAN x x /265 E-FAN Air exit filter IP55 Degree of protection IP55 Same design as filter-based fan Fixing in the door without any screws Easy change of filter pads during operation With integrated foam sealing towards the electrical cabinet Cut-out HxW Type Article No. Pack [mm] designation (pcs.) wa_vt x125 EX-FILT x177 EX-FILT x223 EX-FILT EATON CORPORATION CA008008EN

76 Accessories for Panel Building - Filters and Fans Filter pads for filter-based fans and air exit filters Replacement filters Degree of protection IP54/IP55 5 filters per package Suitable fordimensions Degree of Type Article No. Pack [mm] protection designation (pcs.) wa_vt00114, wa_vt fan1/...filt1 87x87 IP54 FILT FAN2/...FILT2 119x119 IP54 FILT FAN3/...FILT3 170x170 IP54 FILT FAN4/...FILT4 216x216 IP54 FILT FAN2-55/...FILT x108 IP55 FILT FAN3-55/...FILT x156 IP55 FILT FAN4(-5)-55/...FILT x200 IP55 FILT EATON CORPORATION CA008008EN

77 Accessories for Panel Building - Filters and Fans Filter-based fan IP54 Installation without tools Fast changing of filter pads Modular structure, easy installation of accessories and additional components Easy and variable electrical connection Technical Data E-FAN1 E-FAN2 E-FAN3 E-FAN4 E-FAN5 Mains voltage ±10% 230V AC 50/60Hz 230V AC 50/60Hz 230V AC 50/60Hz 230V AC 50/60Hz 230V AC 50/60Hz Air flow - freeblowing 25 / 29 m 3 /h 61 / 70 m 3 /h 110 / 125 m 3 /h 156 / 171 m 3 /h 256 / 292 m 3 /h Air flow - in combination with Air exit filter 16 / 18 m 3 /h 44 / 52 m 3 /h 82 / 93 m 3 /h 116 / 127 m 3 /h 231 / 265 m 3 /h Power consumption 12W / 11W 19W / 18W 19W / 18W 18W / 17W 45W / 39W Current consumption 0,07A / 0,06A 0,12A / 0,18A 0,12A / 0,18A 0,12A / 0,1A 0,32A / 0,26A Noise level acc. to EN ISO dB / 33dB 44dB / 44dB 40dB / 40dB 40dB / 43dB 42dB / 46dB Weight 0.55 kg 0.7 kg 0.87 kg 1.18 kg 1.67 kg Type of connection Cable l = 310mm Terminal strip Terminal strip Spring-type terminal strip Spring-type terminal strip Fuse protection 6A 6A 6A 6A 6A Degree of protection EN60529 / UL 50 IP54 IP54 IP54 IP54 IP54 Filtration efficiency 88% 88% 88% 88% 88% Quality grade of filter pad acc. to DIN EN 779 G 3 G 3 G 3 G 3 G 3 Operating period 100% 100% 100% 100% 100% Type of bearing Slide bearing Slide bearing Slide bearing Ball bearing Ball bearing Service life L10 (+40 C) 52,500h 37,500h 37,500h 40,000h 40,000h Temperature range -40 C C/-40 F F Design (enclosure and contact protection) made of injection-moulded, self-extinguishing thermoplastic, UL 94 VO Colour RAL 7035 RAL 7035 RAL 7035 RAL 7035 RAL 7035 Dimensions (mm) Y Z1 A B mm E-FAN1 E-FAN2 E-FAN3 E-FAN4 E-FAN5 X Y Z Z A B X Z2 76 EATON CORPORATION CA008008EN

78 Accessories for Panel Building - Filters and Fans Filter-based fan IP55 Installation without tools Fast changing of filter pads Modular structure, easy installation of accessories and additional components Easy and variable electrical connection Technical Data E-FAN2-55 E-FAN3-55 E-FAN4-55 E-FAN5-55 Mains voltage ±10% 230V AC 50/60Hz 230V AC 50/60Hz 230V AC 50/60Hz 230V AC 50/60Hz Air flow - free-blowing 56 / 64 m 3 /h 100 / 110 m 3 /h 145 / 160 m 3 /h 233 / 265 m 3 /h Air flow - in combination with Air exit filter 40 / 46 m 3 /h 55 / 64 m 3 /h 109 / 113 m 3 /h 180 / 207 m 3 /h Power consumption 19W / 18W 19W / 18W 18W / 17W 45W / 39W Current consumption 0.12A / 0.18A 0.12A / 0.18A 0.12A / 0.1A 0.32A / 0.26A Noise level acc. to EN ISO dB / 44dB 40dB / 40dB 40dB / 43dB 42dB / 46dB Weight 0.7 kg 0.87 kg 1.18 kg 1.67 kg Type of connection Terminal strip Terminal strip Spring-type terminal strip Spring-type terminal strip Fuse protection 6A 6A 6A 6A Degree of prot. acc. to EN60529 / UL 50 IP55 IP55 IP55 IP55 Filtration efficiency 88% 88% 88% 88% Quality grade of the filter pad acc. to DIN EN 779 G 3 G 3 G 3 G 3 Operating period 100% 100% 100% 100% Type of bearing Slide bearing Slide bearing Slide bearing Ball bearing Service life L10 (+40 C) h h h h Temperature range -40 C C/-40 F F Design (enclosure and contact protection) made of injection-moulded, self-extinguishing thermoplastic material UL 94 VO Colour RAL 7035 RAL 7035 RAL 7035 RAL 7035 Dimensions (mm) Y Z1 A B mm E-FAN2-55 E-FAN3-55 E-FAN4-55 E-FAN5-55 X Y Z Z A B X Z2 77 EATON CORPORATION CA008008EN

79 Accessories for Panel Building - Filters and Fans Air exit filter Same design as filter fans Installation in the door without screws, acc. to VDE 0113 (EN 60204) Recently developed and patented snap-on fixing Filter is easy to change while operating With integrated, foamed sealing towards the electrical cabinet Technical Data EX-FILT1 EX-FILT2 EX-FILT3 EX-FILT4-5 Cut-outs (mm) 92 x x x x 223 Degree of protection IP 54 IP 54 IP 54 IP 54 Colour RAL 7035 RAL 7035 RAL 7035 RAL 7035 Material of enclosure Thermo-plastic material EX-FILT2-55 EX-FILT3-55 EX-FILT Cut-outs (mm) 125 x x x 223 Degree of protection IP 55 IP 55 IP 55 Colour RAL 7035 RAL 7035 RAL 7035 Material of enclosure UV resistant plastic Dimensions (mm) Y Z1 A B mm EX-FILT1(-55) EX-FILT2(-55) EX-FILT3(-55) EX-FILT4-5(-55) X Y Z Z A B X Z2 Filter pads for filter fans and air exit filters Replacement filter pads for filter fans Technical Data FILT1 FILT2 FILT3 FILT4 Dimensions (mm) 87 x x x x 216 Degree of protection IP 54 IP 54 IP 54 IP 54 Material LG3318 LG3318 LG3318 LG3318 FILT2-55 FILT3-55 FILT4-55 Dimensions (mm) 116 x x x 200 Degree of protection IP 55 IP 55 IP 55 Material BN BN BN EATON CORPORATION CA008008EN

80 Accessories for Panel Building - Filters and Fans Filter characteristics E-FAN1 Characteristics of cooling performance Cooling capacity [W] Kühlleistung [W] E-FAN + 2 EX-FILT E-FAN + EX-FILT E-FAN2 Temperature Temperaturdifferenz difference T [K] ΔT [K] Characteristics of cooling performance Cooling capacity [W] Kühlleistung [W] E-FAN + 2 EX-FILT E-FAN + EX-FILT E-FAN2-55 Temperature Temperaturdifferenz difference T [K] ΔT [K] Characteristics of cooling performance Cooling capacity [W] Kühlleistung [W] E-FAN + 2 EX-FILT E-FAN + EX-FILT E-FAN3 Temperature Temperaturdifferenz difference T [K] ΔT [K] Characteristics of cooling performance Cooling capacity [W] Kühlleistung [W] E-FAN + 2 EX-FILT E-FAN + EX-FILT Temperature Temperaturdifferenz difference T [K] ΔT [K] Characteristics of static pressure Statischer Druck [Pa] Static pressure [Pa] EX-FILT 10 2 EX-FILT 5 E-FAN Luftfördermenge Air feed rate [m 2 /h] Characteristics of static pressure Statischer Druck [Pa] Static pressure [Pa] E-FAN Luftfördermenge Air feed rate [m 2 /h] Characteristics of static pressure Statischer Druck [Pa] Static pressure [Pa] EX-FILT 2 EX-FILT 10 E-FAN Luftfördermenge Air feed rate [m 2 /h] Characteristics of static pressure Statischer Druck [Pa] Static pressure [Pa] EX-FILT 2 EX-FILT 20 2 EX-FILT 10 E-FAN Luftfördermenge Air feed rate [m 2 /h] EX-FILT 79 EATON CORPORATION CA008008EN

81 Accessories for Panel Building - Filters and Fans E-FAN3-55 Characteristics of cooling performance Cooling capacity [W] Kühlleistung [W] E-FAN + 2 EX-FILT E-FAN + EX-FILT E-FAN4 Temperature Temperaturdifferenz difference T [K] ΔT [K] Characteristics of cooling performance Cooling capacity [W] Kühlleistung [W] E-FAN + 2 EX-FILT E-FAN4-55 Temperature Temperaturdifferenz difference T ΔT [K] [K] Characteristics of cooling performance Cooling capacity [W] Kühlleistung [W] E-FAN + 2 EX-FILT E-FAN + EX-FILT E-FAN + EX-FILT Temperature Temperaturdifferenz difference T ΔT [K] [K] E-FAN5 Characteristics of cooling performance Cooling capacity [W] Kühlleistung [W] E-FAN + 2 EX-FILT E-FAN + EX-FILT Temperature Temperaturdifferenz difference T ΔT [K] [K] Characteristics of static pressure Static pressure [Pa] Statischer Druck [Pa] EX-FILT 20 2 EX-FILT 10 E-FAN Luftfördermenge Air feed rate [m 2 /h] Characteristics of static pressure Statischer Druck [Pa] Static pressure [Pa] Luftfördermenge Air feed rate [m 2 /h] Characteristics of static pressure Statischer Druck [Pa] Static pressure [Pa] EX-FILT 2 EX-FILT E-FAN 20 2 EX-FILT 10 E-FAN Luftfördermenge Air feed rate [m 2 /h] Characteristics of static pressure Statischer Druck [Pa] Static pressure [Pa] EX-FILT 20 E-FAN Luftfördermenge Air feed rate [m 2 /h] EX-FILT 2 EX-FILT 80 EATON CORPORATION CA008008EN

82 Accessories for Panel Building - Filters and Fans E-FAN5-55 Characteristics of cooling performance Cooling capacity [W] Kühlleistung [W] E-FAN + 2 EX-FILT E-FAN + EX-FILT Temperature Temperaturdifferenz difference T ΔT [K] [K] Characteristics of static pressure Statischer Druck [Pa] Static pressure [Pa] EX-FILT 2 EX-FILT 20 E-FAN Luftfördermenge Air feed rate [m 2 /h] 81 EATON CORPORATION CA008008EN

83 Accessories for Panel Building - Filters and Fans Thermostats and Hygrostats wa_vt01214 UL, cul approval Degree of protection IP20 With NC/NO/CO contacts For on-demand temperature regulation and ventilation in the electrical cabinet wa_vt01714 No more condensation Snap-on mounting onto mounting rail RAL EATON CORPORATION CA008008EN

84 Accessories for Panel Building - Filters and Fans Thermostats Version with NC/NO/CO contact Operating temperature range C Storage temperature range C RAL 7035 Degree of protection IP20 Snap-on mounting onto mounting rail Type of contact Temperature differencetype Article No. Pack for switching designation (pcs.) [K] wa_vt01214 CO with snap-action contact 1 TH-TW-1K NC with snap-action contact <7 TH-O NO with snap-action contact <7 TH-C NC/NO with snap-action contact <7 TH-TWIN Hygrostat/Thermostat Individual and combined devices Degree of protection IP20 Setting range 40-90% rel. humidity RAL 7035 Operating temperature range C Snap-on mounting onto mounting rail Contact Switching temperature Type Article No. Pack differenz designation (pcs.) [K] wa_vt01714 CO ca. 5% HYG CO/Relais ca. 4%, 1K TH-HYG EATON CORPORATION CA008008EN

85 Accessories for Panel Building - Filters and Fans Thermostats Thermostats are used as temperature controls and therefore for controlling filter-based fans and heaters in electrical cabinets The series of twin thermostats unites two thermostats in all kinds of combinations for complex switching tasks Technical Data TH-TW-1K TH-O TH-C TH-TWIN Type of contact CO with NC with NO with NC/NO snap-action contact snap-action contact snap-action contact with snap-action contact Temperature difference for switching 1 K <7 K <7 K <7 K Tolerance for switching point ± 3 K ± 4 K ± 4 K ± 4 K Max. switching capacity (Value between brackets: Inductive load cos ϕ=0,6): NC /NCC V AC/10A (2A) 240 V AC / 10A (2A) NO/NCC V AC/5A (2A) 120 V AC / 15A (2A) DC: max. 30W max. 30W Temperature range for use C ( F) Temperature range for storage C ( F) Type of sensor Bimetal Bimetal Bimetal Bimetal Degree of protection IP 20 IP 20 IP 20 IP 20 Weight 75g 50g 50g 95g Type of connection Screw-type terminals for cable cross-sections of 0.5 to 2.5 mm 2 Special features thermal recovery system Suitable for operation of Fans and heaters Heaters Fans Fans and heaters Installation Snap-on fixing for 35 mm profile rail acc. to EN Colour RAL 7035 RAL 7035 RAL 7035 RAL 7035 Dimensions (mm) mm TH-TW-1K TH-O TH-C TH-TWIN X Y ,5 Z Y Z X 84 EATON CORPORATION CA008008EN

86 Accessories for Panel Building - Filters and Fans Combined Hygrostat/Thermostat Device The electronic combined device includes a thermostat and a hygrostat in a single enclosure and monitors both the rel. humidity and the temperature at the same time and indepently from each other. Technical Data HYG TH-HYG Device version mechanical hygrostat electronic combined device including hygrostat/thermostat Type of contact CO with snap-on contact CO/relay Operating voltage V AC 50 Hz Setting range 40-90% rel. humidity 40-90% rel. hum. / C Difference in temperature for switching approx. 5% approx. 2K ± 1K / ca. 4% rel. hum. ± 1% Resistance to contact change-over - <10mΩ Max. switching capacity (Value between brackets: Inductive load cos ϕ=0,6): NC/NCC V AC/2A (0,2A) 240V AC, 8A (3A) oder 120V AC, 8A (3A) NO/NCC V AC/5A (0,2A) 24V DC, 4A DC: max. 30W - Temperature range for use C ( F) C ( F) Temperature range for storage C ( F) C ( F) Type of sensor Polyamide ribbon - Degree of protection IP 20 IP 20 Weight 55g 85g Type of connection Screw-type terminals for cable cross-sections of 0.5 to 2.5 mm 2 Operating indicator - LED Suitable for operation of Fans and heaters Fans and heaters Installation Snap-on fixing for 35 mm profile rail acc. to EN Colour RAL 7035 RAL 7035 Dimensions (mm) mm HYG TH-HYG X Y 64 80,5 Z Y Z X 85 EATON CORPORATION CA008008EN

87 Accessories for Panel Building - Filters and Fans Electrical Cabinet Heating wa_vt00814 UL, cul approval Degree of protection IP20 to IP55 Rated voltage 230V / 50Hz Heating power W Radiator heating and heater fan wa_vt EATON CORPORATION CA008008EN

88 Accessories for Panel Building - Filters and Fans Radiator heating Degree of protection IP44 Suitable for permanent operation Any mounting position, preferably vertical Aluminium profile, bright anodized Rated voltage 230V / 50Hz Snap-on mounting onto mounting rail Heating Max. Radiator Type Article No. Pack power surface size designation (pcs.) [W] temperature H/W/D [ C] [mm] wa_vt x70x50 R-HEAT-45W x70x50 R-HEAT-100W x70x50 R-HEAT-150W Radiator heating with limited surface temperature Low surface temperature Degree of protection IP44 Suitable for permanent operation Any mounting position, preferably vertical Aluminium profile, bright anodized Rated voltage 230V / 50Hz Snap-on mounting onto mounting rail Heating Max. Radiator Type Article No. Pack power surface size designation (pcs.) [W] temperature H/W/D [ C] [mm] wa_vt ) 95x70x50 R-SHEAT-20W ) 140x70x50 R-SHEAT-30W ) 215x70x50 R-SHEAT-50W Note: 1) Surface temperature at maximal Enclosure inside temperature of +35 C Miniature radiator heating For use in small enclosures Degree of protection IP54 Suitable for permanent operation Any mounting position, preferably vertical Aluminium profile, black anodized Rated voltage 230V / 50Hz Snap-on mounting onto mounting rail Heating Max. Radiator Type Article No. Pack power surface size designation (pcs.) [W] temperature H/W/D [ C] [mm] wa_vt x50x29.5 R-MHEAT-10W x50x29.5 R-MHEAT-20W x75x29.5 R-MHEAT-30W EATON CORPORATION CA008008EN

89 Accessories for Panel Building - Filters and Fans Fan heater Optimal for use in large electrical cabinets Degree of protection IP20 Suitable for permanent operation Any mounting position, preferably vertical Aluminium profile, bright anodized Rated voltage 230V / 50Hz Snap-on mounting onto mounting rail Heating Max. Radiator Type Article No. Pack power surface size designation (pcs.) [W] temperature H/W/D [ C] [mm] wa_vt x85x104 F-HEAT-250W EATON CORPORATION CA008008EN

90 Accessories for Panel Building - Filters and Fans Radiator heating To avoid high levels of air humidity or levels of temperature that are too low Power of W Easy to install thanks to snap-on fitting Technical Data R-HEAT-45W R-HEAT-100W R-HEAT-150W Heating power 45W 100W 150W Max. surface temperature 105 C 130 C 150 C Power consumption 45W 100W 150W Switch-on current 1.8A 5.0A 7.5A Degree of protection IP44 IP44 IP44 Weight 250g 510g 770g Rated voltage 230V AC 50Hz / 60Hz Operating range 110V-250V AC 50Hz /60Hz Permanent operation 100% Temperature range for operation C ( K) Temperature range for storage C ( K) Mounting position any, preferably vertical Device design Aluminium profile, bright anodized Installation type Snap-on fixing for 35 mm profile rail acc. to EN Protection class I Type of connection Connection cable (500mm) Dimensions (mm) Z X Y1 mm R-HEAT-45W R-HEAT-100W R-HEAT-150W X Y Y Z L Y2 L 89 EATON CORPORATION CA008008EN

91 Accessories for Panel Building - Filters and Fans Radiation Heaters with limitation of surface temperatures Low surface temperature Power of 20-50W Easy to mount thanks to snap-on fixing Technical Data R-SHEAT-20W R-SHEAT-30W R-SHEAT-50W Heating power 20W 30W 50W Max. surface temperature 1) 55 C 55 C 55 C Power consumption 20W 30W 50W Switch-on current 1,1A 1,2A 2,3A Degree of protection IP44 IP44 IP44 Weight 320g 450g 770g Rated voltage 230V AC 50Hz / 60Hz Operating range 110V-250V AC 50Hz /60Hz Permanent operation 100% Temperature range for operation C ( K) Temperature range for storage C ( K) Mounting position any, preferably vertical Device design Aluminium profile, bright anodized Installation type Snap-on fixing for 35 mm profile rail acc. to EN Protection class I Type of connection Connection cable (500mm) Dimensions (mm) Z X Y1 mm R-SHEAT-20W R-SHEAT-30W R-SHEAT-50W X Y Y Z L L Y2 Note: 1) Surface temperature at maximal Enclosure inside temperature of +35 C 90 EATON CORPORATION CA008008EN

92 Accessories for Panel Building - Filters and Fans Miniature Radiator Heaters For use in small enclosures Power from 10-30W Easy to mount thanks to snap-on fixture Technical Data R-MHEAT-10W R-MHEAT-20W R-MHEAT-30W Heating power 10W 20W 30W Max. surface temperature 95 C 115 C 140 C Power consumption 10W 20W 30W Switch-on current 1.0A 1.1A 1.2A Degree of protection IP54 IP54 IP54 Weight 85g 120g 120g Rated voltage 230V AC 50Hz / 60Hz Operating range 110V-250V AC 50Hz /60Hz Permanent operation 100% Temperature range for operation C ( K) Temperature range for storage C ( K) Mounting position any, preferably vertical Device design Aluminium profile, black anodized Mounting type Snap-on fixing for 35 mm profile rail acc. to EN Protection class II Type of connection Connection cable (300mm) Dimensions (mm) L mm R-MHEAT-..W X 29,5 Y 45 Z 50 L 300 Y Z X 91 EATON CORPORATION CA008008EN

93 Accessories for Panel Building - Filters and Fans Fan Heaters Optimal for use in large electrical cabinets Power 250W Easy to mount thanks to snap-on fixture Technical Data F-HEAT-250W Heating power 250W Max. surface temperature 70 C Power consumption 260W Switch-on current 2.2 A Degree of protection IP20 Weight 1.035g Air flow 50m 3 /h (50Hz) / 61m 3 /h (60Hz) Rated voltage 230V AC 50Hz / 60Hz Operating range V AC 50Hz /60Hz Permanent operation 100% Temperature range for operation C ( K) Temperature range for storage C ( K) Mounting position any, preferably vertical Device design Aluminium profile, bright anodized Installation type Snap-on fixing for 35 mm profile rail acc. to EN Protection class I Type of connection Connection cable (500mm) Dimensions (mm) mm F-HEAT-250W X 85 Y1 186,5 Y2 90 Y3 65 Z EATON CORPORATION CA008008EN

94 Accessories for Panel Building Cable Gland for Ventilation IP69K Colour RAL 7035 Cable Hole Outer Cable Use of Cable Type Article No Units per Insertion Diameter Diameter NYM/NYY, 4-wire Designation package mm mm mm 2 (pcs.) VT02610 M H05VV-F4x2,5/3x4mm 2, V-M20-VENT NYM 5x1,5/5x2,5mm 2 Ventilation grommet with filter disc, metric or PG For use at the bottom or side of the enclosures, PE and PVC Colour RAL 7035 Cable Insertion Hole Diameter Type Article No Units per mm Designation package (pcs.) VT06608 M KT-M25F PG KT16F Cable Gland for Ventilation IP56 For use at the bottom or side of the enclosures, polyamide, halogen-free Permeable to air, non-permeable to dust To prevent condensation of water Colour RAL 7035 Cable Insertion Hole Diameter Type Article No Units per mm Designation package (pcs.) VT05808 M STB-M20F M STB-M25F Pressure Compensation Gland, IP66, metric Colour RAL 7035 Cable Insertion Type Article No Units per Designation package (pcs.) VT33209 M40x1.5 DAV-M EATON CORPORATION CA008008EN

95 Accessories for Panel Building Pressure Compensation Gland, IP55, PG Colour RAL 7035 Cable Insertion Type Article No Units per Designation package (pcs.) VT01612 PG29 DA EATON CORPORATION CA008008EN

96 Eaton is a power management company with 2015 sales of $20.9 billion. Eaton provides energyefficient solutions that help our customers effectively manage electrical, hydraulic and mechanical power more efficiently, safely and sustainably. Eaton has approximately 97,000 employees and sells products to customers in more than 175 countries. For more information, visit Article number To contact an Eaton salesperson or local distributor/agent, please visit Eaton Industries (Austria) GmbH Scheydgasse Wien Austria Eaton Industries Manufacturing GmbH EMEA Headquarters Route de la Longeraie 1110 Morges Switzerland 2016 Eaton Industries (Austria) GmbH Subject to technical modifications. No responsibility is taken for misprints or errata. Printed in Austria (0 /16) Publication number CA008008EN Grafics: SRA DigiPics, Lithos: Print:

Fuse Switch Disconnectors XNH. Fuse Switch Disconnectors XNH... For fuse links NH000 to NH3. Rated operating current of 160, 250, 400 and 630A

Fuse Switch Disconnectors XNH. Fuse Switch Disconnectors XNH... For fuse links NH000 to NH3. Rated operating current of 160, 250, 400 and 630A www.eaton.eu Panel Building Accessories PIFT Plug In Fused Terminal Fuse Disconnectors Filters and Fans Fuse Switch Disconnectors XNH Thermostats Terminals Catalogue 2017 Electrical Cabinet Heating Fuse

More information

New XNH fuse-switch disconnectors

New XNH fuse-switch disconnectors Eaton xeffect XNH fuse-switch disconnectors www.eaton.eu/xnh New XNH fuse-switch disconnectors with a direct connection to SmartWire-DT Product information 2016 Energizing a world that demands more. We

More information

Vertical fuse disconnects

Vertical fuse disconnects THE NAME FOR SAFETY Vertical fuse disconnects Vertical fuse disconnects Vertical fuse disconnects are designed to receive NH fuse links. Hinged fuse-carriers enable opening and closing operation in electric

More information

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole MULTIBLOC 3.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 3.ST8 comprises NH fuse switch disconnectors for 630A. They are designed for bottom

More information

Special Purpose Fuses

Special Purpose Fuses Special Purpose Fuses Fuses for DC voltage applications www.eti.si ETI Elektroelement d.d. Obrezija 5, SI - 111 Izlake Slovenija Tel. + 38 03 5 57 570 Faks + 38 03 5 7 077 eti@eti.si NH DC 80 V - Telecom

More information

3NP1 Fuse Switch Disconnectors up to 630 A

3NP1 Fuse Switch Disconnectors up to 630 A Switch Disconnectors 3NP1 Fuse Switch Disconnectors up to 630 A Introduction Overview All key product features at a glance available for all sizes Connection of circular conductors and laminated conductors

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole MULTIBLOC 2.RST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC 2.RST8 comprises NH fuse switch disconnectors for 400A. Products are designed in triple

More information

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole MULTIBLOC 1.RST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC 1.RST8 comprises NH fuse switch disconnectors for 250A. Products are designed in triple

More information

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage SENTRON Configuration Manual Edition 10/2015 siemens.com/lowvoltage 2 Introduction LD main control and EMERGENCY-STOP switches up to 250 A 4 Introduction 7 Front mounting 10 Floor mounting 11 Distribution

More information

MULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole

MULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole MULTIBLOC 1.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 1.ST8 comprises NH fuse switch disconnectors for 250A. They are designed for bottom

More information

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV Switch Disconnectors Introduction Siemens AG 2010 Overview 3NP5 0 3NP5 2 3NP5 fuse disconnector range 3NP5 4 SENTRON 3NP5 fuse disconnectors are controls for the occasional manual ing/isolating of loads

More information

MULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole

MULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole MULTIBLOC 2.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 2.ST8 comprises NH fuse switch disconnectors for 400A. They are designed for bottom

More information

Technical data. Busbar support 3 7, 5 6, 8 ETIBUSBAR 1 0, 5 BBS-60/4

Technical data. Busbar support 3 7, 5 6, 8 ETIBUSBAR 1 0, 5 BBS-60/4 Busbar support 20 30 BBS-/1 BBS-/3 57 52 29 29 1 5 3 0 1 5 10 2 0 5 3 7, 5 6 0 6 0 6 0 6, 8 12 1 0, 5 7 5 1 2 5 2 4 0 20 30 18 BBS-/4 563 98,5 10 29 93,5 5 29 18 75 180 10,5 6,8 30 30 25 20 52,5 12 BBS-/3-16

More information

Vertical fuse disconnects

Vertical fuse disconnects Vertical fuse disconnects Vertical fuse disconnects Vertical fuse disconnects are designed to receive NH fuse links. Hinged fuse-carriers enable opening and closing operation in electric circuits under

More information

MULTIVERT 250A Size 1, 690VAC

MULTIVERT 250A Size 1, 690VAC MULTIVERT 250A IEC FUSE SWITCH DISCONNECTORS NH VERTICAL FUSE SWITCH DISCONNECTOR FEATURES & BENEFITS MULTIVERT NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors.

More information

PANEL PANEL MOUNTING COMPONENTS

PANEL PANEL MOUNTING COMPONENTS PANEL PANEL MOUNTING COMPONENTS For conventional wiring, Wöhner offers a comprehensive range of panel components for fastening to a DIN rail or mounting plate. The fuses and associated connection technology

More information

Fuse switch-disconnectors

Fuse switch-disconnectors Fuse switch-disconnector FH00 is intended fuse-links with blade contacts size 000 and 00. It enables safe disconnection not only of rated current, but also overcurrent up to octuple rated current. A version

More information

LV HRC fuse switch-disconnectors

LV HRC fuse switch-disconnectors The 9 series LV HRC fuse switch-disconnectors of the DIN sizes 00-4a are suitable for surface mounting on mounting plates and for direct mounting on busbars. The different sizes are available as 1-pole,

More information

Fuse switch disconnectors

Fuse switch disconnectors SWITCHGEAR RBK Fuse switch disconnectors intended for distribution of electricity and protection of electrical equipment against short-circuits and overloads, with industrial fuse links ENERGY SAFELY SWITCHED

More information

Fuse switch disconnectors

Fuse switch disconnectors SWITCHGEAR 62 RBK pro Fuse switch disconnectors designed for distribution of electricity and protection of electrical equipment against short-circuits and overloads with industrial fuse links. ENERGY SAFELY

More information

Horizontal fuse disconnects

Horizontal fuse disconnects THE NAME FOR SAFETY Horizontal fuse disconnects Horizontal fuse disconnects Horizontal fuse Disconnects are used in building installations, switchgear and controlgear as well as in power utility networks.

More information

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489 Data Sheet System pro M compact for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU200 M is BB s solution for UL 489 branch circuit protection

More information

SENTRON 3NP1 Fuse Switch Disconnectors up to 630 A

SENTRON 3NP1 Fuse Switch Disconnectors up to 630 A Introduction Overview All key product features at a glance available for all sizes Connection of circular conductors and laminated conductors Fuse monitoring possible throughout Busbar supports can be

More information

Power distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly

Power distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly NH fuse-switch disconnectors, size 000 Version -pole, cable outlet at the top/bottom For the use of fuse inserts to EN 60 - Technical specifications to IEC/EN 60 947-, see chapter -5, page 6 see chapter

More information

Electronic overload relays EF205 and EF370

Electronic overload relays EF205 and EF370 Data sheet Electronic overload relays EF205 and EF370 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

Vertical fuse disconnects

Vertical fuse disconnects THE NAME FOR SAFETY Vertical fuse disconnects Vertical fuse disconnects Vertical fuse disconnects are designed to receive NH fuse links. Hinged fusecarriers enable opening and closing operation in electric

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

Varius SUMMARY OF MODELS

Varius SUMMARY OF MODELS SUMMARY OF MODELS FH000 FH00 FH FH2 FH LTL4a Rated operating current I e 60 A 60 A 250 A 400 A 60 A 600 A Rated operating voltage AC/DC U e 690 V 690 V 690 V 690 V 690 V 690 V Size 000 00 2 4a Fuse-link

More information

The Complete Range. Drawing of the NH Fuse-Switch, 3-pole switching, horizontal design for busbar supply on a 60 mm busbar systems

The Complete Range. Drawing of the NH Fuse-Switch, 3-pole switching, horizontal design for busbar supply on a 60 mm busbar systems The Complete Range Easy mounting onto supporting rails Protection against accidental contact in the standart version Perforated versions for connections Drawing of the NH Fuse-Switch, 3-pole switching,

More information

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU 200 M is ABB s solution for UL 489 branch

More information

MULTIBLOC 000.ST8 Size 000, 100A, 690VAC, Design for Bottom Fitting, Triple Pole

MULTIBLOC 000.ST8 Size 000, 100A, 690VAC, Design for Bottom Fitting, Triple Pole MULTIBLOC 000.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR FEATURES & BENEFITS The production programme of MULTIBLOC 000.ST8 comprises NH fuse switch disconnectors for 100A. They are designed

More information

Fuse switch-disconnectors

Fuse switch-disconnectors Fuse switch-disconnector FH000 is intended for fuse-links with blade contacts size 000. It enables safe disconnection not only of rated current, but also overcurrent up to octuple rated current. A version

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking MainswitchRearmounting Partno. T0-2-1/V/SVB-SW Articleno. 045992 Front IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches

More information

Thermal overload relay TF65 and TF96

Thermal overload relay TF65 and TF96 Data sheet Thermal overload relay TF65 and TF96 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against overload and

More information

MOULDED CASE CIRCUIT BREAKERS BC160N

MOULDED CASE CIRCUIT BREAKERS BC160N D MOULDED CASE CIRCUIT BREAKERS BC160N D BC160N COMMERCIAL INFORMATION Circuit breakers...d4 Switch-disconnectors...D5 Connecting sets......d6 Mounting sets......d6 Switches...D7 Shunt trips...d7 Undervoltage

More information

vertical fuse switch disconnectors

vertical fuse switch disconnectors SWITCHGEAR ARS vertical fuse switch disconnectors - touch protection IP 30 from the front - fibre glass extra strenghtened, self extinguishing thermoplastics - double clearance between open contacts -

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays are the alternative to the thermal overload relays. An electronic overload relay offers reliable and fast protection

More information

SENTRON Switching and Protection Devices Switch Disconnectors

SENTRON Switching and Protection Devices Switch Disconnectors SENTRON Switching and Protection Devices Switch Disconnectors /2 Introduction 3K, 3KE, 3LD Switch Disconnectors 3K, 3KE Switch Disconnectors up to 1000 /4 General data /8 Floor mounting 3LD Main and EMERGENCY-STOP

More information

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A Fuse protection fuser_737_a_1_cat.eps fuser_738_a_1_cat.eps The solution for > Motor load break > Protection of industrial processes FUSERBLOC REAR / FRONT connections 3 x 250 A fuser_739_a_1_cat.eps Strong

More information

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking MainswitchSurfacemounting Partno. P1-25/I2/SVB-SW Articleno. 207294 IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches

More information

Thermal overload relay TF140DU and TF140DU-V1000

Thermal overload relay TF140DU and TF140DU-V1000 Data sheet Thermal overload relay TF140DU and TF140DU-V1000 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against

More information

MS General Information Extended Product Type: MS

MS General Information Extended Product Type: MS MS132-1.6 General Information Extended Product Type: MS132-1.6 Product ID: 1SAM350000R1006 EAN: 4013614400063 Catalog Description: MS132-1.6 Manual Motor Starter Long Description: The MS132-1.6 manual

More information

D509E. Manual Motor - Starters

D509E. Manual Motor - Starters D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A Fuse protection fuser_548_a cat The solution for > Motor load break. > Protection of industrial cabinet. FUSERBLOC 6 to 25 A Strong points fuser_52_a cat Function FUSERBLOC 2 to 4 A FUSERBLOC are manually

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A Fuse protection fuser_548_a_1_cat The solution for > Motor load break > Protection of industrial processes FUSERBLOC 63 to 125 A Strong points fuser_532_a_1_cat Function FUSERBLOC 32 to 4 A FUSERBLOC are

More information

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A Load break switches SIRCO MV PV sircm-pv_010_a_1_cat The solution for > Residential buildings > Buildings > Solar parks Strong points SIRCO MV PV 1000 V - 80 A direct operation > Modular device > Patented

More information

185mm-System power 2500A. Expertise

185mm-System power 2500A. Expertise 185mm-System power 2500A Expertise System advantages The 185mm-System power is designed for use in efficient power distribution assemblies with a high short-circuit withstand capacity. The narrow design

More information

Thermal Overload Relays

Thermal Overload Relays Data Sheet Thermal Overload Relays Ex9RD Series Ex9RD93 Ex9RD25 www.noarkusa.com NOARK Ex9RD Series Thermal overload relays are economic electromechanical protection devices for the main circuit. They

More information

FUSE BASES NH FUSE BASES 690V 160A 160A

FUSE BASES NH FUSE BASES 690V 160A 160A fuse bases NH NH 14 690V NH 16 ACCESSORIES FOR NH 18 CR 690V NH 20 SECTIONABLE NEUTRAL NH BASES 21 BS FUSE SWITCH DISCONNECTORS 690V NH NH Fuse bases for NH fuse links. For mounting on DIN/EN rail or

More information

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0 MainswitchSurfacemounting Partno. T0-2-1/I1/SVB-SW Articleno. 207148 IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches

More information

PANEL-MOUNTING COMPONENTS SWITCHGEAR. Technology

PANEL-MOUNTING COMPONENTS SWITCHGEAR. Technology PANEL-MOUNTING COMPONENTS SWITCHGEAR Technology QUADRON CrossLinkBreaker Disconnects and provides fuse protection for currents up to 100A Sizes 000 to 2 can be mounted quickly on DIN EN 50 022 rails using

More information

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories Page 1 of 5 MS132-10 ABB contact for United States of America General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: MS132-10 1SAM350000R1010 4013614400100 MS132-10

More information

NH-Fuse system Low voltage

NH-Fuse system Low voltage 38103-FER NH-fuses A4-engl 22.10.2003 15:50 Uhr Seite 3 NH-Fuse system Low voltage 38103-FER NH-fuses A4-engl 22.10.2003 14:01 Uhr Seite 2 Utilization NH-fuses gg am gtr NH-fuses Utilization Categories

More information

Size 00-4a LV HRC fusebases. plates and for direct mounting on busbars. In addition, they serve as bases for LV HRC fuselinks

Size 00-4a LV HRC fusebases. plates and for direct mounting on busbars. In addition, they serve as bases for LV HRC fuselinks Product family fuse-bases Size 00-4a fusebases are suitable for surface mounting on mounting plates and for direct mounting on busbars. In addition, they serve as bases for fuselinks in accordance with

More information

Approved Standards. Ordering Information. Thermal Overload Relay J7TKN. Model Number Legend. Thermal Overload Relay. Accessories

Approved Standards. Ordering Information. Thermal Overload Relay J7TKN. Model Number Legend. Thermal Overload Relay. Accessories Thermal Overload Relay J7TKN ) Thermal Overload Relay Direct and separate mounting Single phasing sensivity according to IEC 60947-4-1 Finger proof (BGV A2) Accessories Set for single mounting Approved

More information

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33 BA511*33 COMMERCIAL INFORMATION Type designation specification for ordering...146 (design and circuit breaker and switch-disconnector accessories selection, circuit breaker rated current selection) Connecting

More information

Varius SUMMARY OF MODELS

Varius SUMMARY OF MODELS Varius SUMMARY OF MODELS Type FH00 FH1 FH2 FH3 LTL4a Rated operating current I e 160 A 160 A 250 A 400 A 630 A 1 600 A Rated operating voltage AC/DC U e 690 V 690 V 690 V 690 V 690 V 690 V Size 000 00

More information

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE Switch disconnectors A modular and flexible range Contact gap 7 mm (norm 5.5 mm) Reversible terminal feature ÿ IN ENCLOSURE - Degree of protection: up to IP 66 - For 25A to 100A size switches (see Ithe

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

FL series position switches

FL series position switches FL series position switches Selection diagram 0 08 0 9 0 0 0 Ball Ø. External rubber Ball Ø 8 mm, mm, stainless Glass fibre rod gasket stainless steel steel Adjustable lever Adjustable safety lever Bistable

More information

9-0. Product family. LV HRC fuse switch-disconnectors. Surface mounting Busbar mounting

9-0. Product family. LV HRC fuse switch-disconnectors. Surface mounting Busbar mounting Product family fuse switch-disconnectors The 9 series fuse switch-disconnectors of the DIN sizes 00-4a are suitable for surface mounting on mounting plates and for direct mounting on busbars. The different

More information

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1 MainswitchSurfacemounting Partno. T0-2-8900/I1/SVB Articleno. 207151 CatalogNo. CT02-8900-I1CRQ Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual

More information

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077 Data Sheet System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077 2CDC021026S0011 2CDC021016S0012 The S 200 PR is a high-performance supplementary protector with

More information

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

RX 3 MCB 4500 A Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 RX 3 MCB 4500 A CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Safety rope switches with reset for emergency stop

Safety rope switches with reset for emergency stop Safety rope switches with reset for emergency stop Selection diagram 8 8 83 ACTUATORS ACTUATORS CONTACT BLOCKS 18 9 21 1NO+ FP FD FL FC 22 33 34 LED signalling light CONDUIT ENTRIES For other available

More information

Control switch/load disconnect switch Series 8008

Control switch/load disconnect switch Series 8008 > s Control switch with 2, 3 or 4 pole Load switch 3 pole + 1 auxiliary contact > Rated operational voltage up to 690 V AC > Positive opening contacts > Contacts suitable for EM-STOP > Isolating characteristics

More information

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, 4 Electrics for Rolling Stock Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, Change-Over-Switches 600 V to 3 kv Catalogue F84.en

More information

Special Purpose Fuses

Special Purpose Fuses Special Purpose Fuses Multimeter fuses Metering Fuses Telecom fuses NH 80V Fuses for DC voltage applications NH am 00V a.c. NH gg 0V a.c. Safe work fuses SWF Fuses for protection of forklift batteries

More information

CATALOG. EasyLine XLP Fuse Switch Disconnector poles

CATALOG. EasyLine XLP Fuse Switch Disconnector poles CATALOG EasyLine XLP Fuse Switch Disconnector 1-2-3-4 poles 2 E A S Y L I N E X L P F U S E S W I TC H D I S C O N N E C TO R 1-2 - 3-4 P O L E S Contents 004 005 Introduction EasyLine XLP 006 007 Introduction

More information

Protection Equipment

Protection Equipment Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection

More information

Vistop TM isolating switches 63 to 160A

Vistop TM isolating switches 63 to 160A DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary

More information

MULTIVERT 1000A Main Incomer, 690VAC

MULTIVERT 1000A Main Incomer, 690VAC IEC FUSE SWITCH DISCONNECTORS NH VERTICAL FUSE SWITCH DISCONNECTOR FEATURES & BENEFITS MULTIVERT NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors. They are designed

More information

Safety rope switch without reset for simple stop

Safety rope switch without reset for simple stop afety rope switch without reset for simple stop election diagram FP 4-M2 FD 4-M2 FL 4-M2 FR 4-M2 FM 4-M2 FX 4-M2 FZ 4-M2 ACTUATOR 9 ACTUATOR 9 0 CONTACT BLOCK 1 9 21 1NO+ FP FD FL FC 33 34 CONDUIT ENTRIE

More information

Typ 415 NH-Sicherungsleisten, BTVA/BTVA-P, NH 1/2/3, 250/400/630 A, 185mm Sammelshienenabstand

Typ 415 NH-Sicherungsleisten, BTVA/BTVA-P, NH 1/2/3, 250/400/630 A, 185mm Sammelshienenabstand LV-SWITCHING DEVICES / NH-SCHALTGERÄTE 1 Vertical 415 design fuse rails TRIVER / NH-Sicherungsleisten TRIVER Range / Produktpalette Type 415 fuse rails BTVA/BTVA-P, NH 1/2/3, 2/400/, mm busbars spacing

More information

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DNX 3 MCB 4500 A / 6 ka CONTENTS PAGE 1. Description, use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation

More information

Manual motor starter MS132

Manual motor starter MS132 Data sheet Manual motor starter MS132 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

Low voltage NH knife-blade fuse-links

Low voltage NH knife-blade fuse-links Low voltage NH knife-blade fuse-links NV KOMBI advantages ETI is introducing a new generation of low-voltage fuse-links from size NV00C up to NV3 with new, dual indication of fuse-link operation, called

More information

W Datasheet: DIN Rail Contactors, series AMPARO

W Datasheet: DIN Rail Contactors, series AMPARO W Datasheet: DIN Rail Contactors, series AMPARO W SCHRACK-INFO For suiting of fans, pumps, heating & lighting Noise reducing design Low vibration on DIN-rail 230V 50/60Hz oder 24V 50/60 Hz coil DIN-Rail

More information

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved

More information

Manual motor starter MS132

Manual motor starter MS132 Data sheet Manual motor starter MS132 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

Cylindrical fuse-link

Cylindrical fuse-link Cylindrical fuse-link Technical data Rated voltage Rated current Rated frequency Rated breaking capacity Characteristics ody material 00 V AC, 00 V AC, 90 V AC CH 8 - A/00 V CH 0,- A/00 V, 0-3 A/00 V CH

More information

Circuit Breakers BZM. Product Information. Circuit Breaker BZM1 16 to 125 A. Circuit Breaker BZM2 125 to 250A. BZM1 & BZM2 Accessories

Circuit Breakers BZM. Product Information. Circuit Breaker BZM1 16 to 125 A. Circuit Breaker BZM2 125 to 250A. BZM1 & BZM2 Accessories Circuit Breakers BZM Product Information Circuit Breaker BZM1 16 to 125 A Circuit Breaker BZM2 125 to 250A BZM1 & BZM2 Accessories Optimum and Efficient Protection for Every Application Compact Simple

More information

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en Snap-action switches S80, S85, S86 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D0.en Snap-action switches, S80, S85, S86 Series Single-break

More information

MC FRAME SIZE 1 / UP TO 160A

MC FRAME SIZE 1 / UP TO 160A 8 W CIRCUIT BREAKER 3 POLE UP TO 160A WITH THERMAL MAGNETIC RELEASE TYPES MC1B-A, MC1N-A, MC1H-A For system and line protection Adjustable overload release Ir: 0,8 1 x In (factory setting 0,8 x In) Adjustable

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

PKZ and PKE motor-protective circuit-breakers

PKZ and PKE motor-protective circuit-breakers PKZ and PKE motor-protective circuit-breakers Machinery and installation downtimes should be kept as short as possible. The PKZ fuseless motor-protective circuit-breakers combine short-circuit and overload

More information

Varius SUMMARY OF MODELS

Varius SUMMARY OF MODELS SUMMARY OF MODELS Type 10 14 22 OPT22/OPT20 OPVF10 Rated operating current I e / Rated current I n 32 A / - 63 A / - 125 A / - 63 A / - - / 30 A Rated operating voltage U e / Rated voltage U n AC 690 V

More information

Safety switches for hinges

Safety switches for hinges Safety switches for hinges Selection diagram ACTUATORS L L6 L9 L16 FR FM FX FZ FK CONTACT BLOCKS 6 7 9 14 18 snap action 1NO+1N, make before break, shifted, close 21 4 66 NC 2NO+ 1NO+ CONDUIT ENTRIES Threaded

More information

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation Motor-protectivecircuit-breaker,3p,Ir=2.5-4A Partno. PKZM01-4 Articleno. 278482 CatalogNo. XTPB004BC1 Deliveryprogramme Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton

More information

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail 87045 LIMOGES Cedex Telephone number: +33 (0)5 55 06 87 87 Fax: +33 (0)5 55 06 88 88 DX 3 4500 A / 6 ka CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information

SIRIUS 3RU2 Thermal Overload Relays

SIRIUS 3RU2 Thermal Overload Relays Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors. The overload relay can be connected directly to

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

Load and Motor Switches, Load-Break Switches Series 8544

Load and Motor Switches, Load-Break Switches Series 8544 www.stahl.de > Innovative switch concept > State-of-the-art contact arrangement > Easy and clear connection technology > Wiring channel for auxiliary contacts > Retrofittable: Alligator clip Auxiliary

More information

Safety switches with separate actuator

Safety switches with separate actuator Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD5 VF KEYD6 VF KEYD7 VF KEYD8 VF KEYD10 VF KEYD11 ACTUATORS CONTACT BLOCKS FR FX FK FW 5 6 7 11 1 14 NC NC

More information

Thermal Overload Relays - WEG RW Series, 2 Pole

Thermal Overload Relays - WEG RW Series, 2 Pole International (5) 4-07 The RW Class Thermal Overload Relays, with their extended operational service lives, are designed for use with the CWC miniature and CWM standard contactors. These relays can be

More information

Phase + Neutral, neutral on left side

Phase + Neutral, neutral on left side 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 DX 3 MCB 10000 A / 16 ka CONTENTS PAGE 1. Description, use...1 2. Range...1 3. Overall dimensions...1 4. Preparation - Connection...1

More information