NH LOW VOLTAGE a FUSE SYSTEM
|
|
- Madlyn Fitzgerald
- 5 years ago
- Views:
Transcription
1 NH LOW VOLTAGE a FUSE SYSTEM
2 NH DIN Low Voltage Fuse System from Cooper Bussmann High Breaking Capacity 400Vac, 500Vac and 690Vac Insulated Tag variants available Dual Indication VDE 066 Part 1 DIN 4 60 Parts 1 to 4 (Standard Dimensions) Cooper Bussmann low voltage NH DIN fuse links are manufactured in the following sizes, current ratings and operating class: Size 000/C00 Size 00 Size C0 & 0 Size 01 Size 1 Size 0 Size Size 0 Size A to 100A 15A & 160A 6A to 160A 6A to 160A 00A to 50A 5A to 50A 15A to 400A 50A to 400A 500A to 60A Size 4 Size 4a 60A to 1600A from 400A to 1600A The Bussmann NH DIN low voltage fuse links are available at 400Vac, 500Vac and 690Vac and includes fuse links to DIN VDE 066. All products are manufactured to the dimensional requirements of DIN Approvals The NH DIN low voltage fuse system offered by Cooper Bussmann includes fuse links bearing the following symbols: NH DIN Fuse Links with Dual Indication Today, the majority of NH-fuse links according to DIN 4 60 have two different types of indicator system. The most common type has the indicator located on the top end plate of the fuse link. In most cases this is used for visual indication, although it can also be used to operate a micro-switch where remote indication is required. The second type of indicator is located in the centre of the ceramic body of the fuse link. When used in conjunction with NH open style fuse bases, the top indicator provides the end-user with effective visual indication of operation of the fuse link. However, when used in fuse rails or fuse switch-disconnectors, it is extremely difficult to identify the operated fuse link. This is when centre indication is required. However, manufacturers offering the centre indicator type have struggled to produce a design of NH-fuse link that will offer the same reliability as the top indicator device. Manufacturers of the centre indicator have had to put up with high failure rates and this results in a poor quality fuse link coupled with a poor quality of service, in the eyes of the end user. The dual indicating NH fuse link from Bussmann incorporates the top and centre indicator systems into a single fuse link body. All users benefit from a reliable and effective NH-fuse link complimented by a proven dual-indication system irrespective of whether the fuse is situated in a fuse base, fuse switchdisconnect or vertical fuse rail and regardless of application. The dual indication NH fuse range is available at 500Vac for ratings from 6 to 60 Amps. The standard industrial design incorporates aluminium, non-isolated extraction tags. The interrupt rating 10kA at 500Vac. For more information visit our website at
3 400 Vac Class gl-gg with Class gl-gg with Class gl-gg with Size Rated voltage conducting voltage conducting voltage-free metal Pack Current (A) metal gripping lugs metal gripping lugs gripping lugs Quantity and central indication and central indication NH000G-400 NH000GC-400 NH000GC-400 I 4 4NH000G-400 4NH000GC-400 4NH000GC-400 I 6 6NH000G-400 6NH000GC-400 6NH000GC-400 I 10 10NH000G NH000GC NH000GC-400 I NH000G NH000GC NH000GC-400 I 0 0NH000G-400 0NH000GC-400 0NH000GC-400 I 5 5NH000G-400 5NH000GC-400 5NH000GC-400 I NH000G-400 NH000GC-400 NH000GC-400 I 5 5NH000G-400 5NH000GC-400 5NH000GC-400 I 40 40NH000G NH000GC NH000GC-400 I 50 50NH000G NH000GC NH000GC-400 I 6 6NH000G-400 6NH000GC-400 6NH000GC-400 I 80 80NH00G NH00GC NH00GC-400 I NH00G NH00GC NH00GC-400 I 15 15NH00G NH00GC NH00GC-400 I NH00G NH00GC NH00GC-400 I 5 5NH1G-400 5NH1GC-400 5NH1GC-400 I 40 40NH1G NH1GC NH1GC-400 I NH1G NH1GC NH1GC-400 I 6 6NH1G-400 6NH1GC-400 6NH1GC-400 I 80 80NH1G NH1GC NH1GC-400 I NH1G NH1GC NH1GC-400 I 15 15NH1G NH1GC NH1GC-400 I NH1G NH1GC NH1GC-400 I NH1G NH1GC NH1GC-400 I 4 4NH1G-400 4NH1GC-400 4NH1GC-400 I 50 50NH1G NH1GC NH1GC-400 I 40 40NHG NHGC NHGC-400 I 50 50NHG NHGC NHGC-400 I 6 6NHG-400 6NHGC-400 6NHGC-400 I NHG NHGC NHGC-400 I NHG NHGC NHGC-400 I 15 15NHG NHGC NHGC-400 I NHG NHGC NHGC-400 I 00 00NHG NHGC NHGC-400 I 4 4NHG-400 4NHGC-400 4NHGC-400 I 50 50NHG NHGC NHGC-400 I 15 15NHG NHGC NHGC-400 I 55 55NHG NHGC NHGC-400 I NHG NHGC NHGC-400 I 15 15NHG NHGC NHGC-400 I 55 55NHG NHGC NHGC-400 I NHG NHGC NHGC-400 I 45 45NHG NHGC NHGC-400 I NHG NHGC NHGC-400 I 60 60NHG NHGC NHGC-400 I For more information visit our website at
4 500 Vac Class gl-gg with Class gl-gg with Class am with Size Rated voltage conducting voltage-free metal voltage conducting Pack Current (A) gripping lugs and gripping lugs and gripping lugs Quantity dual-indication central indication 000 & NHG000B 10NHC00GCI 10NHC00M 16 16NHG000B 16NHC00GCI 16NHC00M 0 0NHG000B 0NHC00GCI 0NHC00M 5 5NHG000B 5NHC00GCI 5NHC00M NHG000B NHC00GCI NHC00M 5 5NHG000B 5NHC00GCI 5NHC00M 40 40NHG000B 40NHC00GCI 40NHC00M 50 50NHG000B 50NHC00GCI 50NHC00M 6 6NHG000B 6NHC00GCI 6NH00M 80 80NHG000B 80NHC00GCI 80NH00M NHG000B 100NHC00GCI 100NH00M 15 15NHG00B 15NH00GCI 15NH00M NHG00B 160NH00GCI 160NH00M a 10 10NHG0B 10NH0GCI 10NH0M 16 16NHG0B 16NH0GCI 16NH0M 0 0NHG0B 0NH0GCI 0NH0M 5 5NHG0B 5NH0GCI 5NH0M NHG0B NH0GCI NH0M 5 5NHG0B 5NH0GCI 5NH0M 40 40NHG0B 40NH0GCI 40NH0M 50 50NHG0B 50NH0GCI 50NH0M 6 6NHG0B 6NH0GCI 6NH0M 80 80NHG0B 80NH0GCI 80NH0M NHG0B 100N0GCI 100NH0M 15 15NHG0B 15NH0GCI 15NH0M NHG0B 160NH0GCI 160NH0M 6 6NH01GCI 6NH01M 10 10NHG01B 10NH01GCI 10NH01M 16 16NHG01B 16NH01GCI 16NH01M 0 0NHG01B 0NH01GCI 0NH01M 5 5NHG01B 5NH01GCI 5NH01M NHG01B NH01GCI NH01M 5 5NHG01B 5NH01GCI 5NH01M 40 40NHG01B 40NH01GCI 40NH01M 50 50NHG01B 50NH01GCI 50NH01M 6 6NHG01B 6NH01GCI 6NH01M 80 80NHG01B 80NH01GCI 80NH01M NHG01B 100N01GCI 100N01M 15 15NHG01B 15NH01GCI 15NH01M NHG01B 160NH01GCI 160NH01M 00 00NHG1B 00NH1GCI 00NH1M 4 4NHG1B 4NH1GCI 4NH1M 50 50NHG1B 50NH1GCI 50NH1M 5 5NHG0B 5NH0GCI 5NH0M 40 40NHG0B 40NH0GCI 40NH0M 50 50NHG0B 50NH0GCI 50NH0M 6 6NHG0B 6NH0GCI 6NH0M 80 80NHG0B 80NH0GCI 80NH0M NHG0B 100N0GCI 100N0M 15 15NHG0B 15NH0GCI 15NH0M NHG0B 160NH0GCI 160NH0M 00 00NHG0B 00NH0GCI 00NH0M 4 4NHG0B 4NH0GCI 4NH0M 50 50NHG0B 50NH0GCI 50NH0M 15 15NHGB 15NHGCI 15NHM 55 55NHGB 55NHGCI 55NHM NHGB 400NHGCI 400NHM 50 50NHG0B 50NH0GCI 50NH0M 15 15NHG0B 15NH0GCI 15NH0M 55 55NHG0B 55NH0GCI 55NH0M NHG0B 400NH0GCI 400NH0M NHG0B 450NH0GCI 450NH0M NHGB 500NHGCI 500NHM 60 60NHGB 60NHGCI 60NHM 60 60NH4G NH4G NH4G NH4G NH4AG NH4AG NH4AG NH4AG NH4AG NH4AG NH4AG Size 4 & 4a are standard indication 4 For more information visit our website at
5 690 Vac Size Class gl-gg with Class am with Rated voltage conducting voltage conducting Pack Current (A) metal gripping lugs gripping lugs Quantity C00 & 00 C00 & NH00G-690 6NHC00M NH00G NHC00M NH00G NHC00M NH00G-690 0NHC00M NH00G-690 5NHC00M-690 NH00G-690 NHC00M NH00G-690 5NHC00M NH00G NHC00M NH00G NHC00M NH00G-690 6NH00M NH00G NH00M NH00G NH00M NH00G NH00M NH00G NH00M-690 C0 & 0 1 C0 & 0 6 NH0G-690 6NHC0M NH0G NHC0M NH0G NHC0M NH0G-690 0NHC0M NH0G-690 5NHC0M-690 NH0G-690 NHC0M NH0G-690 5NHC0M NH0G NHC0M NH0G NHC0M NH0G-690 6NH0M NH0G NH0M NH0G N0M NH0G NH0M NH0G NH0M NH1G NH1G NH1G NH1G NH1M NH1G N1M NH1G NH1M NH1G NH1M NH1G NH1M NH1G NH1G NHG NHG NHM NHG NHM NHG NHM NHG-690 4NHM NHG NHM NHG NHM NHG NHM NHG NHM NHM NHG NHM NHG NHM NHG NHM NHM NHG NHM NHG NHM-690 For more information visit our website at 5
6 FUSE LINKS FOR THE PROTECTION OF TRANSFORMERS 400 Vac Nominal Rated Current Class gtr with Size Rating of (1rat) voltage conducting Pack Transformer metal gripping lugs Quantity (kva) NHGTr NHGTr NHGTr NHGTr NHGTr NHGTr NHGTr 4a NHGTr NHGTr NHGTr NHGTr NHGTr NHGTr NHGTr NHGTr NHGTr NHGTr NHGTr NH4GTr NH4GTr NH4GTr NH4GTr NH4GTr NH4GTr NH4GTr NH4GTr NH4GTr NH4GTr NH4GTr FUSE LINKS FITTED WITH STRIKER 500 Vac and 690 Vac Size Rated Voltage Class gl-gg with Class am with Current (A) (Vac) voltage conducting voltage conducting Pack metal gripping lugs metal gripping lugs Quantity NH1G-S 6NH1M-S 80 80NH1G-S 80NH1M-S NH1G-S 100NH1M-S 15 15NH1G-S 15NH1M-S NH1G-S 160NH1M-S 00 00NH1G-S 00NH1M-S 50 50NH1G-S 50NH1M-S NH1G-S NH1G-S NHG-S 15NHM-S NHG-S 160NHM-S NHG-S 00NHM-S 50 50NHG-S 50NHM-S 15 15NHG-S 15NHM-S 55 55NHG-S 55NHM-S NHG-S 400NHM-S 45 45NHG-S NHG-S NHG-S NHG-S NHG-S 400NHM-S 45 45NHG-S 45NHM-S NHG-S 500NHM-S 60 60NHG-S 60NHM-S NHG-S NH4G-S NH4G-S NH4G-S NH4G-S NH4G-S For more information visit our website at
7 NH FUSE BASES & ACCESSORIES Fuses Bases and Accessories Available in multiple pole configurations for sizes 000 to 4 to DIN 4 60 & IEC Rated current range is 160A to 150A Thermoplastic base resistant to high temperature and self-extinguishable Ceramic fuse bases also available Silver plated contacts with high-contact pressure springs Fixation by DIN rail or screw Accessories include separating plates, terminal covers and fuse covers allowing IP-0 protection Fuse Rails Available in Sizes 000 to to IEC6069, DIN VDE Part 1 Rated current range is 160A to 60A Thermostable reinforced polyester; selfextinguishable Electrolytic cooper contacts and busbars Stainless steel contact springs Protection level of IP-0 Fuse Switch Disconnectors Available for size 000 to to DIN VDE 0660 Part 107 IEC Rated current range is 160A to 150A For use with Class gg and am fuse links DIN 4 60 Horizontal and Vertical style fuse switch Disconnectors -Pole and 1-Pole switchable For more information visit our website at 7
8 IEC CYLINDRICAL FUSE SYSTEM LOW VOLTAGE FUSE LINKS CIRCUIT PROTECTION SOLUTIONS Bussmann are one of the world s leading suppliers of fuses and fusible protection systems. Provider of the world s first truly NH FUSE SYSTEM LOW VOLTAGE FUSE LINKS global product line, each product is backed by an efficient world-wide distribution IEC BUSBAR FUSE SYSTEM D & DO LOW VOLTAGE FUSE SYSTEM network service and unrivalled technical support. Bussmann circuit protection solutions comply with major international standards: BS, IEC, DIN and UL. IEC BUSBAR FUSE SYSTEM CONTRACTOR PRODUCTS A comprehensive range of circuit HIGH VOLTAGE PRODUCTS HIGH SPEED FUSES protection solutions fused and non-fused. NHSS - 00 HIGH SPEED FUSES HIGH VOLTAGE PRODUCTS Cooper Bussmann Cooper (UK) Limited Burton-on-the-Wolds Leicestershire LE1 5TH UK Telephone: 44 (0) Facsimile: 44 (0) Your Representative Cooper Bussmann 00. Printed February 00 A Industries Company.
SINCE 989 Quality Products, Prompt Services, Trustful Relationships www.kmindustrialcorp.com KM Industrial Corporation has established itself as a trusted supplier of Electrical, Machinery and Industry
More informationNH Dual NHIndicator Fuse System Fuse System
NH Dual NHIndicator Fuse System Fuse System Product Product Guide Guide NH Dual Indicator System Catalogue NH Dual Indicator Fuse System Class gg/gl - 400Vac - 2 to 60 Amps - s 000 to Part Numbers 400Vac
More information500 Volts gg/gl NH Fuse links
Technical Data 101 Supersedes December 01 BUSSMANN SERIES Product description Eaton s Bussmann series 500 Volts NH square bodied industrial fuse links are suitable for a wide variety of applications. Standard
More informationClass gg/gl, 690Vac, 2 to 500 Amps, Sizes 000 to 3 NH Series
Description: A range of Class gg/gl square bodied industrial fuse links for a variety of applications. Packaging: MOQ: 3 Catalogue Symbol: Class of Operation: (amp)nhg(size)b-690 gg/gl Fuse Size: 000 to
More informationD & D0 LOW VOLTAGE FUSE SYSTEM
elay (Class gl/gg) and UltraRapid (gr) characteristics rated at 00Vac. Similar to the D0 system the D system is designed to IEC9 and VDE0. DType Fuse Links Selection Table DI Fuse Links fuse base E D DR
More informationLOW VOLTAGE FUSES EUROPEAN NH KNIFE-BLADE FUSE SYSTEM
NH SIBA NH Fuse-links with top and center indicator are available in a large variety of voltage ratings, body sizes and operating classes: Sizes: 000, 00, 0, 1, 2, 3 and 4 Voltage ratings: AC 400 / 500
More informationNH DIN Dual Indication Fuse Links Class am, 690Vac, 6 to 500 Amps, Sizes 000 to 3 NH Series
Description: A range of Class am square bodied industrial fuse links for a wide variety of motor protection applications. Packaging: MOQ: 3 Catalogue Symbol: Class of Operation: (amp)nhm(size)b-690 am
More informationIEC Low Voltage Products Module 4
IEC Low Voltage Products Module 4 IEC Low Voltage Products NH DIN o All variations o Features benefits o Dual indication IEC Cylindrical Fuse System o Wide range of sizes and ratings o CCP NEW Product!
More informationCircuit Protection Solutions Product Guide
Circuit Protection Solutions Product Guide Product Guide Low Voltage Fuses and Fusegear NH DIN Industrial fuse links and bases Conforms to IEC 60269 & VDE 0636 General purpose full range & Motor protection
More informationNH HRC Fuses. IEC & British Standard Fuses NHG B
NH HRC Fuses NHG B Specifications Class: gg/ g L Description: DIN square bodied, dual indication industrial fuses. Construction: Steatite insulator, corrosionproof (aluminum) metal parts with full-contact,
More informationFuses for Semiconductor Protection European Standard Sizes 000 and 00. Protection of Power Semiconductors according to IEC and -4
URB Fuses for Semiconductor Protection European Standard Sizes 000 and 00 Class: ar Voltage ratings: AC 660 V AC 1000 V Current ratings: 16 A to 400 A Approvals: Standards: DIN 43653 IEC 60269-1 and -4
More informationNH fuse-links gg 500VAC size 000, 00, 0, 1, 2, 3
IEC LV NH fuse links with blade contacts The NH system is classified among plug-in fuse systems and is composed of: fuse-base, (possibly including terminal covers and phase barriers) fuse-link with blade
More informationBussmann series NH catalogue. Leadership in circuit protection
Bussmann series NH catalogue Leadership in circuit protection Energizing a world that demands more. We deliver: Electrical solutions that use less energy, improve power reliability and make the places
More informationNH DIN Dual Indication Fuse Links
Class gg/gl, 400Vac, 2 to 630 Amps, Sizes 000 to 3 Standards/Approvals IEC 60269, VDE 0636, DIN 43620 Part 1 and 3 Description A square bodied range of industrial fuse links for a wide variety of applications.
More information500 and 690 V a.c. am NH fuse links
Supersedes September 2015 BUSSMANN SERIES Product description Eaton s Bussmann series NH 500 and 690 Volts, class am, industrial fuse links are suitable for a wide variety of motor protection applications.
More informationNH Bases BUSSMANN SERIES. Technical Data Product description. Standard features
Supersedes August 2017 BUSSMANN SERIES Product description Eaton s Bussmann series have been designed with thermoplastic bodies DIN-Rail and/or screw mounting (size 4 screw mounting only). This range comes
More informationnew NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price
NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price gg fuselinks 500V (IEC60269 - VDE0636 - DIN43620) with fuse blown indication NH Fuse links gg class with high
More informationBussmann NH Bases. Technical Data Effective October Product description: Standard features:
Technical Data 10163 Bussmann NH Bases Product description: Bussmann s range of NH bases has been designed with thermoplastic bodies, DIN-Rail and/or screw mounting (size 4 screw mounting only). This range
More informationLeadership in Circuit Protection
Leadership in Circuit Protection Bussmann is now a part of Eaton Leadership in Circuit Protection. The only company that can provide a complete circuit protection solution for all applications. Only Eaton
More informationLeadership in Circuit Protection
Leadership in Circuit Protection Bussmann is now a part of Eaton Learn more at Eaton.com/Cooper Leadership in Circuit Protection. The only company that can provide a complete circuit protection solution
More informationCircuit Protection Solutions. Low Voltage Fuse Links Catalogue
Circuit Protection Solutions Low Voltage Fuse Links Catalogue Table of Contents Domestic Applications to BS161 & BS11 Consumer Fuse Link 4 Plug Top Fuse Links 4 Industrial & Motor Applications to BS88
More informationNH-Fuse system Low voltage
38103-FER NH-fuses A4-engl 22.10.2003 15:50 Uhr Seite 3 NH-Fuse system Low voltage 38103-FER NH-fuses A4-engl 22.10.2003 14:01 Uhr Seite 2 Utilization NH-fuses gg am gtr NH-fuses Utilization Categories
More informationIEC CYLINDRICAL FUSE SYSTEM
IEC CYLINDRICAL FUSE SYSTEM European Domestic and Industrial Fuse Links The Bussmann range of European cylindrical fuse links are available in a broad selection of physical sizes and current ratings for
More informationInternational products
Section Overview With over 25 locations around the globe, Littelfuse is the supplier of choice when it comes to international fuses, fuseholders and accessories. With an ever expanding portfolio of products
More informationFUSE BASES NH FUSE BASES 690V 160A 160A
fuse bases NH NH 14 690V NH 16 ACCESSORIES FOR NH 18 CR 690V NH 20 SECTIONABLE NEUTRAL NH BASES 21 BS FUSE SWITCH DISCONNECTORS 690V NH NH Fuse bases for NH fuse links. For mounting on DIN/EN rail or
More informationNH DIN Dual Indication Fuse Links
Class of Operation gl/gg, 500V AC, 10 to 630 s Sizes 000 to 3 Standards/ Approvals: Description: Packaging: IEC 60269, VDE0636, DIN 43 620 1 to 4. A square bodied range of industrial fuse links for a wide
More informationPANEL PANEL MOUNTING COMPONENTS
PANEL PANEL MOUNTING COMPONENTS For conventional wiring, Wöhner offers a comprehensive range of panel components for fastening to a DIN rail or mounting plate. The fuses and associated connection technology
More informationNH fuse-links gtr 400VAC top indicator/live gripping-lugs size 2, 3, 4a
NH fuse-links gtr 400VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS The NH system is classified among plug-in fuse systems and is composed of: fuse-base, (possibly including terminal covers
More information2013 JEAN MÜLLER Products
2013 JEAN MÜLLER Products Company JEAN MÜLLER JEAN MÜLLER was founded in 1897 in Germany, when the applications of electricity were still in their very early days. The company chose as its basic activity
More informationNH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3
NH fuse-links gg 4VAC double indicator/live gripping-lugs size,, 1, 2, 3 NH fuse-links gg 4VAC double indicator/live gripping-lugs size,, 1, 2, 3 LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS
More informationBussmann series NH bases
Supersedes October 2013 BUSSMANN Product description Eaton s range has been designed with thermoplastic bodies DIN-Rail and/or screw mounting (size 4 screw mounting only). This range comes with a accessories
More informationNH photovoltaic fuse links
Technical Data 72033 Supersedes January 207 BUSSMANN SERIES Product description Eaton s Bussmann series NH size photovoltaic fuse links are specifically designed to protect and isolate photovoltaic array
More informationLow voltage NH knife-blade fuse-links
Low voltage NH knife-blade fuse-links NV KOMBI advantages ETI is introducing a new generation of low-voltage fuse-links from size NV00C up to NV3 with new, dual indication of fuse-link operation, called
More informationUtilisation category gl/gg 500VAC with combi indicator
DIN-fuse-links DIN fuse-links are used for the protection of electrical installations and equipment and are common for a wide area of applications. Standardised characteristics, technical data and dimensions
More informationNH fuse-links am 690VAC top indicator/live tags size 4, 4a
NH fuse-links am 69VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions according to DIN 43 62 parts 1 to 4 Non-isolated gripping lugs Double indicator Lead free contact blades %
More informationOne Source. Fuse monitoring for NH Fuse-Bases or Fuse-Rails
One Source Insulator Clamps for devices Fuse monitoring for NH Fuse-Bases or Fuse-Rails Solid links MM: Bild angeben Content NH Replacement Handles 192 NH Solid-Links 192 Fuse-Monitoring with strikers
More informationIEC and British Standard Fuses.
IEC and British Standard Fuses Section Contents Page Application Data..................... 45-46 CSA Type P and Type D fuses (CDS, CDN & PON)............................47 Tron HRC Form II Class C fuses
More informationMULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole
MULTIBLOC 3.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 3.ST8 comprises NH fuse switch disconnectors for 630A. They are designed for bottom
More informationgg, am NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories NH DIMENSION KNIFE-BLADE FUSE-LINKS, FUSE BASES, AND ACCESSORIES
, am, FUSE BASES, AND ACCESSORIES Ferraz Shawmut NH Fuse-links, sizes 000, 00, 0, 1, 2, 3, 4 and 4a are rated 500 or 690 Volts AC with breaking capacities of 80kA or 120kA. All fuse-links include an indicator
More informationFuses for Semiconductor Protection - European Standard. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits
Fuses for Semiconductor Protection - European Standard Class: ar Voltage ratings: 660V AC to 1000V AC Current ratings: 16 A to 400 A Standards: UL 248-13 IEC 60269-1 & 4 DIN VDE 0636-40 DIN 43653 Approvals:
More informationMM: Bild angeben Content 690 V AC for baseplate, busbar and supporting rail mounting 60 Accessories 62 Technical Data see page 65 NU System The EFEN s
Basic Efficiency up to 1500 V 1-pole 3-pole SILAS MM: Bild angeben Content 690 V AC for baseplate, busbar and supporting rail mounting 60 Accessories 62 Technical Data see page 65 NU System The EFEN successfully
More informationPANEL-MOUNTING COMPONENTS FUSE HOLDERS. Quality
PANEL-MOUNTING COMPONENTS FUSE HOLDERS Quality For conventional wiring, Wöhner offers a comprehensive range of panel components for fastening to a DIN rail or mounting plate. The fuses and associated
More informationMULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole
MULTIBLOC 2.RST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC 2.RST8 comprises NH fuse switch disconnectors for 400A. Products are designed in triple
More informationStandardized fuse characteristics
Product family "Fuses offer unique advantages compared to other protective devices." Standardized fuse characteristics and high current limitation guarantee easy and reliable coordination between HV HRC
More informationPanel-mounting components
Quality Panel-mounting components For conventional cabling, Wöhner offers a comprehensive range of panel components suitable for either plate or DIN-rail mounting. Fuses and the associated connection technology
More informationype UP T Busplugs Low Voltage Switchboard Equipment
Busplugs Type UP Low Voltage Switchboard Equipment Publication UP 2013 Since product improvement is a continuing policy, we reserve the right to change specifications without notice. Contents Descriptive
More informationShort Circuit. Sizes 0, 1, 2, and 690 Volt ratings - 32A through 630A All ratings include striker. 0% Lead
, am nh dimension knife-blade fuse-links, fuse bases, and accessories Ferraz Shawmut NH Fuse-links, sizes 000, 00, 0, 1, 2, 3, 4 and 4a are rated 500 or 690 Volts AC with breaking capacities of 80kA or
More informationSpecial Purpose Fuses
Special Purpose Fuses Fuses for DC voltage applications www.eti.si ETI Elektroelement d.d. Obrezija 5, SI - 111 Izlake Slovenija Tel. + 38 03 5 57 570 Faks + 38 03 5 7 077 eti@eti.si NH DC 80 V - Telecom
More informationGears & Fuse Gears. IEC General Purpose Fuses DIN Fuses Fuse Switch-disconnectors
D0 LINOCUR Switch-Disconnector for NEOZED Fuses 63 A D02 230/400 VAC (440VAC) New ergonomically designed screw caps Switch-disconnector with spring-operated mechanism for automatic connection Locking device
More informationFUSE-LINKS FOR PHOTOVOLTAIC APPLICATIONS
1 2 06 PML 10/14x85 1500V FUSE HOLDERS 08 CLIP CONTACT FOR φ10 FUSE LINKS 05 PMX & 14x51 FUSE HOLDERS 02 gpv & 14x51 600 &/1100 FUSE LINKS 03 gpv 1200 & 1500V FUSE LINKS 04 gpv NH1, NH2 & NH3 FUSE LINKS
More informationMULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole
MULTIBLOC 1.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 1.ST8 comprises NH fuse switch disconnectors for 250A. They are designed for bottom
More informationXL Photovoltaic fuse links
Technical Data 020 Supersedes November 207 BUSSMANN SERIES Product description Eaton s Bussmann series XL fuse links are specifically designed to protect and isolate photovoltaic array combiners and disconnects.
More informationMULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole
MULTIBLOC 2.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 2.ST8 comprises NH fuse switch disconnectors for 400A. They are designed for bottom
More informationGeneral Purpose IEC Fuses
Line protection fuses gl-gg IEC 60269 parts1, 3 and 3-1 DIN VDE 0636 Parts 10, 30 and 31 Dimensions are stipulated in the following regulations: DIN 49360 D Fuse-links DIN 49515 D Fuse-links DIN 49367
More informationfuse-links & fuse holders PHOTOVOLTAIC
fuse-links & fuse holders 04 gpv FOR APPLICATIONS 04 gpv FOR APPLICATIONS 05 gpv & FOR APPLICATIONS 06 PMF FUSE HOLDERS FOR APPLICATIONS 07 ST & FUSE BASES FOR APPLICATIONS FUSE HOLDERS & BASES gpv 10x38
More informationNH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a
LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions in accordance with DIN 43 62 Live tags Top indicator Lead free contact blades % cadmium APPLICATIONS gg: General purpose (protection
More information185mm-System power 2500A. Expertise
185mm-System power 2500A Expertise System advantages The 185mm-System power is designed for use in efficient power distribution assemblies with a high short-circuit withstand capacity. The narrow design
More informationMULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole
MULTIBLOC 1.RST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC 1.RST8 comprises NH fuse switch disconnectors for 250A. Products are designed in triple
More informationNH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a
NH fuse-links gg 69VAC NH fuse-links gg 69VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions in accordance with DIN 43 62 Live tags Top indicator Lead free contact blades % cadmium
More informationHHD. High Voltage Fuses German DIN Standard. The temperature limiting function of the fuse striker pin. Design and construction.
HHD High Voltage Fuses German DIN Standard For Air & Gas Insulated Switchgear Indoor and Outdoor Application The striker pin system is connected by means of a high resistance parallel conductor. After
More informationMULTIBLOC 000.ST8 Size 000, 100A, 690VAC, Design for Bottom Fitting, Triple Pole
MULTIBLOC 000.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR FEATURES & BENEFITS The production programme of MULTIBLOC 000.ST8 comprises NH fuse switch disconnectors for 100A. They are designed
More informationVertical fuse disconnects
Vertical fuse disconnects Vertical fuse disconnects Vertical fuse disconnects are designed to receive NH fuse links. Hinged fuse-carriers enable opening and closing operation in electric circuits under
More informationType Pack size Weight Part no. kg/100 units for undrilled busbars 30, 40, 50, 60 x 10. Dimensions Current Pack size Weight Part no.
1 01 628 01 617 01 79 01 25 Universal busbar support 100mm, 3-pole Type Pack size Weight Part no. for undrilled busbars 30, 0, 50, 60 x 10 7.1 01 79 06 End cover for busbar support 01 79 10 5.3 01 25 06
More informationFUSES. Safety through quality
Safety through quality HH HIGH VOLTAGE Over many decades SIBA has developed a global product line of High Voltage Fuses that are comprehensive for any and all applications. Superior engineering, advanced
More informationgi-gl-gg, am gi-gl-gg gi-gl-gg NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories
,, FUSE BASES, AND ACCESSORIES Ferraz Shawmut NH Fuse-links, sizes 00, 0, 1, 2, 3 and 4 are rated 500 or 690 Volts AC with breaking capacities of 80kA or 120kA. All fuse-links include an indicator or striker
More informationUltraSafe US22 Modular fuse-holders
UltraSafe US22 FUSE HOLDERS, FUSE BASES AND SUPPORTS UL/CSA FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive UltraSafe range of Mersen fuse-holders. are finger-safe under IEC standards
More informationvertical fuse switch disconnectors
SWITCHGEAR ARS vertical fuse switch disconnectors - touch protection IP 30 from the front - fibre glass extra strenghtened, self extinguishing thermoplastics - double clearance between open contacts -
More informationHorizontal fuse disconnects
THE NAME FOR SAFETY Horizontal fuse disconnects Horizontal fuse disconnects Horizontal fuse Disconnects are used in building installations, switchgear and controlgear as well as in power utility networks.
More informationHigh Speed Fuses Size 5
Size 5 WORLD-WIDE CIRCUIT PROTECTION SOLUTIONS ussmann manufacture a wide range of products for the protection of electrical and electronic circuits... Fuse Links, Fuse Holders, and Fusegear, all readily
More informationLow-Peak 600V Class RK1
LPS-RK 600Vac/300Vdc, 1 10-60A, Dual Element, Time-Delay Fuses Dimensions - in 5" (± 0.31) 5.5" (± 0.31) Available with easyid open fuse indication 1/10 to 30A 0.81" (±0.008) 35 to 60A 1.06" (±0.008) Description:
More informationLimitor -G General Purpose Fuses
Limitor -G General Purpose Fuses HIGH VOLTAGE IEC FUSES DIN HV GENERAL PURPOSE FUSES FOR TRANSFORMERS FEATURES & BENEFITS Mersen HV fuse-links have been used for reliable protection in high-voltage switchgear
More informationHHD HIGH VOLTAGE FUSES GERMAN DIN STANDARD. The temperature limiting function of the fuse striker pin. Design and construction.
HHD HIGH VOLTAGE GERMAN DIN STANDARD FOR AIR & GAS INSULATED SWITCHGEARS OUTDOOR SWITCHGEARS The striker pin system is connected by means of a high resistance parallel conductor. After melting the main
More informationFUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A
Fuse protection fuser_737_a_1_cat.eps fuser_738_a_1_cat.eps The solution for > Motor load break > Protection of industrial processes FUSERBLOC REAR / FRONT connections 3 x 250 A fuser_739_a_1_cat.eps Strong
More informationIEC Low Voltage General Purpose Protection
, 6A, 0/400VAC (/440VAC) Complying with DIN VDE 0660 Part 07 EN / IEC 60947- DIN VDE 066 Part IEC 6069- DIN VDE 068 DIN VDE 4880 The D0-LINOCUR is a combination of switch-disconnector-fuse and NEOZED 6
More information6-0. Product family. LV HRC strip-fuseways
Product family strip-fuseways strip-fuseways in accordance with DIN 43623 are mainly used for power distribution in cable distribution cabinets and low voltage power supply distribution systems. They are
More informationBussmann series Product range overview. Leadership in fusible circuit protection solutions
Bussmann series Product range overview Leadership in fusible circuit protection solutions Energizing a world that demands more. We deliver: Electrical solutions that use less energy, improve power reliability
More informationFUSERBLOC Fuse combination switches for industrial fuses up to 1250 A
Fuse protection fuser_548_a_1_cat The solution for > Motor load break > Protection of industrial processes FUSERBLOC 63 to 125 A Strong points fuser_532_a_1_cat Function FUSERBLOC 32 to 4 A FUSERBLOC are
More informationHV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION. March 2017
HV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION March 2017 HV FUSE-LINKS IN THE WORLD UL STANDARD E OR R RATED: AMERICAN STANDARD DIN STANDARD: GERMAN STANDARD FR STANDARD: FRENCH STANDARD BS STANDARD: BRITISH
More informationBussmann series NH photovoltaic fuse links
Technical Data 72033 Supersedes April 204 Bussmann series NH photovoltaic fuse links BUSSMANN SERIES Product description Eaton s Bussmann series NH size photovoltaic fuse links are specifically designed
More informationNH (H.R.C) FUSES AND FUSE BASES
NH (H.R.C) FUSES AND FUSE BASES NH (H.R.C) Fuses NHC-FB (A...A) NH-FB (A...A) NH-FB (A...A) NH-FB (8A...4A) NH-FB (A...A) NH-FB (A...A) NH (H.R.C) Fuse Bases STEATIT NH-FA NH-FA NH-FA NH-FA NH-FA CONTENTS
More informationMedium Voltage current limiting Fuse links
Medium Voltage current limiting Fuse links Type PCEF for indoor and outdoor use Rated Voltage 12-24 kv Current Rating 6 0A 1. General information P&C Medium Voltage fuse-links named PCEF are designed to
More informationBussmann series Product range overview. Leadership in fusible circuit protection solutions
Bussmann series Product range overview Leadership in fusible circuit protection solutions * We make what matters work.* At Eaton, we believe that power is a fundamental part of just about everything people
More informationCompact Circuit Protector (CCP)
UL Class CC, Midget and IEC 10x38 fuses The revolutionary Cooper Bussmann CCP is 1/3 the footprint of a molded case circuit breaker. The level of protection provided by the CCP is up to three times the
More informationD Type (DIAZED) FUSE-LINKS & SCREW CAP HOLDERS. EURO/IEC Fuses & Accessories 500 VOLT D TYPE DIAZED FUSE-LINKS, SCREW CAPS AND FUSE BASES
D Type (DIAZED) FUSE-LINKS & SCREW CAP HOLDERS 500 VOLT D TYPE DIAZED FUSE-LINKS, SCREW CAPS AND FUSE BASES Ferraz Shawmut D fuse-links, also called Diazed type, are 500 Volts AC rated with 75kA interrupting
More informationBUSSMANN. LIMITRON FNQ-R Class CC 600Vac, A, time-delay fuses SERIES. Technical Data Carton quantity: Catalog symbol: Dimensions - in:
Supersedes January 204 BUSSMANN SERIES LIMITRON FNQ-R Class CC 600Vac, 4-30A, time-delay fuses Catalog numbers (amps) FNQ-R- 4 FNQ-R--3 FNQ-R-3-2 FNQ-R-8 FNQ-R-3 FNQ-R--4 FNQ-R-3-2 FNQ-R-9 FNQ-R-4 FNQ-R--
More informationNH fuse-links am VAC with striker, size 0, 1, 2, 3, 4
NH fuse-links am 500-690VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions according to DIN 43 620 Parts 1 to 4 Lead free contact blades 0% cadmium APPLICATIONS am: Partial purpose,
More informationBussmann series IEC cylindrical fuses
IEC and ritish Standard fuses 5 Contents ussmann series IEC cylindrical fuses Complete portfolio of 8-22 mm diameter Class am and Class gg cylindrical fuses for industrial applications escription Fuses
More informationDIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV.
DIN HV Distribution DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from 2.3-38kV. Their compact dimensions and non-venting characteristics make them
More informationHigh-voltage high-breaking capacity VV fuse-links
High- high- VV fuse-links [A] (ka) [mω] [W] [A 2 s] [A 2 s] 12 580 4 6,1 57 4 A 20 370 9 17,3 164 6 A 25 260 10 36 340 10 A 46 55 7 161 1 530 16 A 60 37 13 250 2 270 20 A 80 30 15 430 3 750 25 A 105 25
More informationMedium Voltage current limiting Fuse links
Medium Voltage current limiting Fuse links Type PCEF for indoor and outdoor use Rated Voltage 12-24 kv Current Rating 6 200A 1. General information P&C Medium Voltage fuse-links named PCEF are designed
More informationVertical fuse disconnects
THE NAME FOR SAFETY Vertical fuse disconnects Vertical fuse disconnects Vertical fuse disconnects are designed to receive NH fuse links. Hinged fuse-carriers enable opening and closing operation in electric
More informationMINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS
MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MANUFACTURED IN THE EU EUROPEAN QUALITY 1, 2 & 3 POLE MCB s TRIPPING CURVES C & D CURRENT RATINGS 1AMP TO 63AMPS 10KA BREAKING CAPACITY
More informationBETA Fuses and Fuse Systems
Introduction Overview Application LV HRC fuses are used for installation systems in non-residential, commercial and industrial buildings as well as in the switchboards of power supply companies. Fuses
More informationBussmann series IEC cylindrical fuses
IE and ritish Standard fuses 5 ontents ussmann series IE cylindrical fuses Section page escription Fuses S Type P and fuses (N, S and PON) HR Form II lass fuses (GL) 3 HRI industrial ceramic body fuses
More informationfuses fuse holders CYLINDRICAL
fuses fuse holders 02 gg FUSES 04 am FUSES FUSES 09 PMC COMPACT 09 -CC FOR CC CLASS FUSE-LINKS 11 PMB PLUG CONNECTION 11 CLIP CONTACT FOR φ10 FUSE-LINKS 10 PMF 11 BAC OPEN FUSE BASES 06 gg FUSES FUSES
More informationRiLine mm system technology for the global market
60 system technology for the global market 02 RiLine60 Busbar systems 3 and 4 pole Support + bars + contact hazard protection Flat copper bar system, see 276 in HB 33 PLS busbar system, see 278 in HB 33
More informationSENTRON Switching and Protection Devices Switch Disconnectors
SENTRON Switching and Protection Devices Switch Disconnectors /2 Introduction 3K, 3KE, 3LD Switch Disconnectors 3K, 3KE Switch Disconnectors up to 1000 /4 General data /8 Floor mounting 3LD Main and EMERGENCY-STOP
More informationJCAM SWITCHES. Model Ratings / Product Numbering System...J2 Technical Data...J3
Springer Controls is partnered with MERZ-PCE, a world leader in the manufacturing of switch gears. We offer complete line of Cam Switches with as many as 24 switch contacts. Each contact has two fixed
More informationSection Contents. Disconnect Switches
Section Contents Page Compact Circuit Protector (CCP) fused disconnect switches....................326-329 Fused, dead front disconnect switches...........329 Fusible Disconnect Switch Overview............330
More informationModulostar CMS10 Modular fuse-holders
Modulostar CMS10 FUSE HOLDERS, FUSE BASES AND SUPPORTS IEC CYLINDRICAL FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive Modulostar range of Mersen fuse-holders. are finger-safe under IEC
More information