1 INNOZED D0 fusebases with touch protection INNOZED D0 fusebases with touch protection FUSE HOLDERS, FUSE BASES AND SUPPORTS IEC D0 & D FUSE BASES FEATURES & BENEFITS INNOZED is a fuse base for D0 fuselinks, sizes D01 and D02. It is designed for a fast mounting on DIN rail in distribution boards and panels, for residential and industrial applications. INNOZED has an integrated touch protection cover, that prevents from electrocution in builtin status. The use of combtype busbars allows the positioning of the wires to be visually controlled. The use of wiring bus bars in the lower area of the terminal allows an easier insertion of the wires and visual control of the termination points at the same time. INNOZED allows a flexibility in the connection configuration. The fixing clamps consist of two separate compartments, that ensures a secure connection of two different wires. It is possible to use wires with different crosssections from 4mm² to 35mm² or two similar wires up to 16mm² cross section. TECHNICAL DATA OVERVIEW Voltage AC Voltage DC Amper (A) SCCR 400 VAC 250 VDC 63 A 50 ka (AC), 8 ka (DC) Mounting Installation on to DIN rails to EN Body Material plastic, silicon and halogen free Contact Materials Screws +/ (PZ2), galvanized, chromized (Chrome 3) Product Size Number of Poles D01,D02 1pole, 3pole Single pole and triple pole design Snap on fixing for DINrails 35mm Multi termination of 2 conductors (35mm² + 16mm²) or comb bus bar and cable possible Frame clamp mm² fine stranded for direct clamping or with wire end sleeve, M = Nm Space saving fuse base High safety during installation, operation and maintenance Extensive touch protection due to integrated cover Double function clamp up to 35mm² Large termination area and good termination conditions for outgoing feeders Installation in 45mm standard cut out Materials used are synthetic, free of silicon and halogen APPLICATIONS Distribution boards for residential use panel boards for industrial use STANDARDS IEC/EN VDE Fuse Holders, Fuse Bases and Supports / DSLADID0IN071116_EN EP.MERSEN.COM 1

2 INNOZED D0 fusebases with touch protection PRODUCT RANGE INNOZED D01 16 A, 400 V AC single pole E14 Design Weight kg 1 Package W both sides double function clamp mm² weight in kg per piece or set including package INNOZED D01 16 A, 400 V AC triple pole E14 Design Weight kg 1 Package X both sides double function clamp mm² weight in kg per piece or set including package INNOZED D02 63 A, 400 V AC single pole E18 Design Weight kg 1 Package Y both sides double function clamp mm² weight in kg per piece or set including package INNOZED D02 63 A, 400 V AC triple pole E18 Design Weight kg 1 Package Z both sides double function clamp mm² weight in kg per piece or set including package TECHNICAL DATA IN ACCORDANCE WITH EN / IEC INNOZED D01, 16A 1pole INNOZED D01, 16A 3pole INNOZED D02, 63A 1pole INNOZED D02, 63A 3pole Number of poles/phases Rated operational current I e 16 A 16 A 63 A 63 A Max. power dissipation of fuse links P n 2,5W 2,5W 5,5W 5,5W Rated operational voltage U e 400V AC, 250V DC 400V AC, 250V DC 400V AC, 250V DC 400V AC, 250V DC Rated short circuit making capacity with fuse links U e = AC 400 V; I e = 16 A U e = AC 400 V; I e = 63 A U e = DC 250 V; I e = 16 A U e = DC 250 V; I e = 63 A 50 ka 8 ka Rated impulse withstand voltage U imp 6 kv 6 kv 6 kv 6 kv Rated frequency 50 Hz 50 Hz 50 Hz 50 Hz Fire resistance UL 94 UL 94 UL 94 UL 94 Cable terminal connection Standard cable terminal frame clamp 1 535mm² 50 ka 8 ka frame clamp 1 535mm² 50 ka 8 ka frame clamp 1 535mm² 50 ka 8 ka frame clamp 1 535mm² Size D01 D01 D02 D02 Temperature resistance 120 C 120 C 120 C 120 C Track resistance/comperative tracking index CTI 200 CTI 200 CTI 200 CTI 200 Fuse Holders, Fuse Bases and Supports / DSLADID0IN071116_EN EP.MERSEN.COM 2

3 INNOZED D0 fusebases with touch protection DIMENSIONS INNOZED D0 fuse base with touch protection Dimensions in mm ACCESSORIES D0 screw caps 400V AC synthetic Description Weight Package E D01, E14, 16A, with testing hole 11.8 g P D02, E18, 63A, with testing hole 11.6 g R D01, E14, 16A, with sealing and testing hole 11.6 g S D02, E18, 63A, with sealing and testing hole 11.6 g L D02, E18, 63A, without testing hole 12 g M D02, E18, 63A, with adapter insert for fuse links size D g 20 D0 screw caps 400/440 VAC, 250 V DC porcelain, with removal grips Description Weight Package H D01, E14, 16A, with testing hole 16.4 g T D02, E18, 63A, with testing hole 18.5 g F D01, E14, 16A, with testing hole 16.4 g 20 Fuse Holders, Fuse Bases and Supports / DSLADID0IN071116_EN EP.MERSEN.COM 3

4 INNOZED D0 fusebases with touch protection ACCESSORIES D0 cartridge ring adapter inserts D01 E14 Description Weight Package J A, pink 0.4 g J A, brown 0.4 g P A, green 0.4 g M A, red 0.4 g D0 cartridge ring adapter inserts D02 E18 Description Application Weight Package S A, blue 0.5 g R A, yellow 0.6 g J A, black 0.5 g R A, white 0.7 g K A, pink For D01 fuse links in D02 fuse bases 0.5 g S A, brown For D01 fuse links in D02 fuse bases 0.6 g R A, green For D01 fuse links in D02 fuse bases 0.6 g H A, red For D01 fuse links in D02 fuse bases 0.6 g Q A, grey For D01 fuse links in D02 fuse bases 0.5 g 50 Fuse Holders, Fuse Bases and Supports / DSLADID0IN071116_EN EP.MERSEN.COM 4

5 INNOZED D0 fusebases with touch protection ACCESSORIES Wiring bars / Insulated bus bars Design Weight Package M single pole, 16 mm², peg design, Lshaped 171 g K J L E K G R triple pole, 16 mm², peg design, Lshaped single pole, 35 mm², peg design, Lshaped triple pole, 35 mm², peg design, Lshaped for single pole wiring bus bar endcover for triple pole wiring bus bar for triple pole wiring bus bars up to 16 mm² for triple pole wiring bus bars up to 35 mm² 638 g g g g g g g Fuse Holders, Fuse Bases and Supports / DSLADID0IN071116_EN EP.MERSEN.COM 5

6 LINOCUR LINOCUR IEC FUSE SWITCH DISCONNECTORS D0 FUSE COMBINATION UNITS The D0 Linocur is a combination of switch disconnector fuse and Neozed 63A fuselink, equiped with significant safety characeristics and sophisticated switching and terminal technology. The power dissipation of Neozed fuselinks leads to internal heating in the Linocur device. Special design measures have been implemented in the development of Linocur in order to prevent the device from overheating and avoid the unwanted, premature operation of the fuselink: generously sized, solid copper strip conductors highly sprung foot contact wide area of heat transfer through contact with the screw cap wide area of contact at the foot contact special contacts which share functions Thanks to this design, Linocur features one of the lowest power dissipation values on the market for D0 fusecombination units devices. FEATURES & BENEFITS Lowest Power Dissipation Remote fuse monitoring (optional) Highly userfriendly and safe changing of the fuse Bayonett design of the screw cap for quick changing of the fuse Easy installation (feeding from above and below) Double clamp connection for in/ output Modern design Modular system: 1 to 3+N poles, available with and without gauge piece APPLICATIONS Low voltage power distribution for: process industries commercial residential. STANDARDS EN/IEC DIN VDE DIN VDE 0660 Part 107 DIN VDE 0638 DIN VDE 0636 Part 3 IEC IEC Fuse Switch Disconnectors / DSLFDID02LIN100117_EN EP.MERSEN.COM 1

7 LINOCUR TECHNICAL DATA OVERVIEW 1 pole AC 230V Voltage 2, 3, 4 pole AC 400V marine application AC 440V per pole DC 65V Ampere Range (A) A Breaking capacity 50 ka Protection IP 20 AC 22B AC 400V 63A SCCR DC 22B DC 65V/pole AC 23B AC 400V 50A AC 23B AC 440V 35A Mounting DIN rail acc. EN Product Size D02 1, 2, 3polar Number of Poles 2polar (1+N) 4polar (3+N) Overvoltage category IV Rated frequency Hz Rated impulse withstand voltage U imp 6 kv Power dissipation 63A: phase=1.8w, neutral=1.4w IEC Fuse Switch Disconnectors / DSLFDID02LIN100117_EN EP.MERSEN.COM 2

8 LINOCUR PRODUCT RANGE D0 Linocur D to 400VAC, 65VDC Rated current In Number of poles/ phases Width Cross section Weight Package Z A 1 27 mm 35 mm² kg J A 2 54 mm 35 mm² 0.32 kg B A 3 81 mm 35 mm² 0.64 kg H A 1+N 54 mm 35 mm² 0.32 kg E A 3+N 108 mm 35 mm² 0.64 kg 1 D0 Linocur D02 220VDC Rated current In Number of poles/phases Width Cross section Weight Package L A mm 35 mm² 0.64 kg 1 D0 Linocur D02 230VAC to 400VAC, 65VDC, with fuselinks and fixed gauge pieces Rated current In Number of poles/ phases Width Cross section Weight Package M A 1 27 mm 35 mm² kg A A 1 27 mm 35 mm² kg B A 2 54 mm 35 mm² 0.32 kg G A 3 81 mm 35 mm² 0.64 kg N A 1 27 mm 35 mm² kg D A 2 54 mm 35 mm² 0.32 kg E A 3 81 mm 35 mm² 0.64 kg C A 1 27 mm 35 mm² kg D A 2 54 mm 35 mm² 0.32 kg P A 3 81 mm 35 mm² 0.64 kg 1 D0 Linocur D02 250VAC to 440 VAC (suitable for marine application) Rated current In Number of poles/ phases Width Cross section Weight Package H A 1 27 mm 35 mm² kg S A 2 54 mm 35 mm² 0.32 kg J A 3 81 mm 35 mm² 0.64 kg T A 3+N 108 mm 35 mm² kg 1 IEC Fuse Switch Disconnectors / DSLFDID02LIN100117_EN EP.MERSEN.COM 3

9 LINOCUR DIMENSIONS Dimensions in mm ACCESSORIES D0 screw caps 400V AC synthetic W K Locking devices J Description Design Weight Package Description Design L Reduction Spring, for the use of D01 fuselinks in the bayonet screw cap Size D01 Replacement srew cap with sealing hole, without testing hole D02, 63A Special key for locking caps 1 g 10 Replacement srew cap with sealing hole, without testing hole D02, 63A Rated current In Weight 32.9 g 1 Locking cap for D0 Linocur, with industrial locking wrench 63A 12.5 g A 6 g 10 Package IEC Fuse Switch Disconnectors / DSLFDID02LIN100117_EN EP.MERSEN.COM 4

10 LINOCUR ACCESSORIES Wiring bars / Insulated bus bars Design Weight Package M single pole, 16 mm², peg design, Lshaped 171 g K L E G R Z A B C D triple pole, 16 mm², peg design, Lshaped triple pole, 35 mm², peg design, Lshaped for single pole wiring bus bar for triple pole wiring bus bars up to 16 mm² for triple pole wiring bus bars up to 35 mm² Eurovario wiring rail fixed length and may not be cut length 159mm, cross section 10mm² Eurovario wiring rail fixed length and may not be cut length 159mm, cross section 16mm² Eurovario wiring rail fixed length and may not be cut length 243mm, cross section 10mm² Eurovario wiring rail fixed length and may not be cut length 243mm, cross section 16mm² special wiring bar to connect Linocur (27mm) with miniature circuit breakers (18mm) length 140mm, cross section 16mm² 638 g g g g g g g g g g Indication facilities G H J Terminal clamps V Design Weight Package Monitoring device for Linocur 2P, 3P, 3P+N Type 1 (switch position), cross section 1,5mm², operating voltage 400V +/10% Monitoring device for Linocur 2P, 3P, 3P+N Type 2 (fuse operation), cross section 1,5mm², operating voltage 400V +/10% Monitoring device for Linocur 2P, 3P, 3P+N Type 3 (switch position and fuse operation), cross section 1,5mm², operating voltage 400V +/10% Design Weight Package Connecting terminal 50mm², insulated, long, cross section 50mm² (if 35mm² rail is used then infeed terminal required) kg kg kg g 10 IEC Fuse Switch Disconnectors / DSLFDID02LIN100117_EN EP.MERSEN.COM 5

INNOZED D0 fuse-bases with touch protection

INNOZED D0 fuse-bases with touch protection D0 fusebases with touch protection D0 fusebases with touch protection FUSE HOLDERS, FUSE BASES AND SUPPORTS IEC D0 & D FUSE BASES FEATURES & BENEFITS is a fuse base for D0 fuselinks, sizes D0 and D02.

More information

LINOCUR Size D02 63A 230VAC/440VAC

LINOCUR Size D02 63A 230VAC/440VAC IEC FUSE SWITCH DISCONNECTORS D0 FUSE COMBINATION UNITS The D0 Linocur is a combination of switch disconnector fuse and Neozed 63A fuse-link, equiped with significant safety characeristics and sophisticated

More information

IEC Low Voltage General Purpose Protection

IEC Low Voltage General Purpose Protection , 6A, 0/400VAC (/440VAC) Complying with DIN VDE 0660 Part 07 EN / IEC 60947- DIN VDE 066 Part IEC 6069- DIN VDE 068 DIN VDE 4880 The D0-LINOCUR is a combination of switch-disconnector-fuse and NEOZED 6

More information

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole MULTIBLOC 2.RST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC 2.RST8 comprises NH fuse switch disconnectors for 400A. Products are designed in triple

More information

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole MULTIBLOC 1.RST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC 1.RST8 comprises NH fuse switch disconnectors for 250A. Products are designed in triple

More information

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole MULTIBLOC 3.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 3.ST8 comprises NH fuse switch disconnectors for 630A. They are designed for bottom

More information

NEOZED D0 fuse-links gg 400/440VAC

NEOZED D0 fuse-links gg 400/440VAC NEOZED D0 fuse-links gg 400/440VAC LOW VOLTAGE IEC FUSES DIN LV FUSE-LINKS D0 FEATURES & BENEFITS The D0 fuse-system is installed in low voltage distribution units, where fuse-links are accessible to non

More information

MULTIBLOC 000.ST8 Size 000, 100A, 690VAC, Design for Bottom Fitting, Triple Pole

MULTIBLOC 000.ST8 Size 000, 100A, 690VAC, Design for Bottom Fitting, Triple Pole MULTIBLOC 000.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR FEATURES & BENEFITS The production programme of MULTIBLOC 000.ST8 comprises NH fuse switch disconnectors for 100A. They are designed

More information

MULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole

MULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole MULTIBLOC 1.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 1.ST8 comprises NH fuse switch disconnectors for 250A. They are designed for bottom

More information

MULTIFIX 60 Universal Bus Bar Carriers

MULTIFIX 60 Universal Bus Bar Carriers MULTIFIX MULTIFIX BUS BAR SYSTEMS COMPONENTS FOR MM SYSTEMS FEATURES & BENEFITS MULTIFIX is a system for energy distribution comprising a variety of modular combinable components. The energy distribution

More information

MULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole

MULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole MULTIBLOC 2.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 2.ST8 comprises NH fuse switch disconnectors for 400A. They are designed for bottom

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information

MULTIVERT 1000A Main Incomer, 690VAC

MULTIVERT 1000A Main Incomer, 690VAC IEC FUSE SWITCH DISCONNECTORS NH VERTICAL FUSE SWITCH DISCONNECTOR FEATURES & BENEFITS MULTIVERT NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors. They are designed

More information

Modulostar CMS10 Modular fuse-holders

Modulostar CMS10 Modular fuse-holders Modulostar CMS10 FUSE HOLDERS, FUSE BASES AND SUPPORTS IEC CYLINDRICAL FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive Modulostar range of Mersen fuse-holders. are finger-safe under IEC

More information

BSL Size 1 250A, Size 2 400A, Size 3 630A, 690VAC

BSL Size 1 250A, Size 2 400A, Size 3 630A, 690VAC BSL Size 1 250A, Size 2 400A, Size 3 630A, 690VAC FUSE RAILS IEC NH FUSE RAILS FEATURES & BENEFITS Installation on to Dimensions of s and cable connections are equivalent to those of MULTIVERT APPLICATIONS

More information

MULTIVERT 250A Size 1, 690VAC

MULTIVERT 250A Size 1, 690VAC MULTIVERT 250A IEC FUSE SWITCH DISCONNECTORS NH VERTICAL FUSE SWITCH DISCONNECTOR FEATURES & BENEFITS MULTIVERT NH vertical fuse switch disconnectors meet all functions of NH fuse switch disconnectors.

More information

Modulostar US10 Modular fuse-holders

Modulostar US10 Modular fuse-holders Modulostar US10 FUSE HOLDERS, FUSE BASES AND SUPPORTS UL/CSA FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive Modulostar range of Mersen fuse-holders. are finger-safe under IEC standards

More information

UltraSafe US22 Modular fuse-holders

UltraSafe US22 Modular fuse-holders UltraSafe US22 FUSE HOLDERS, FUSE BASES AND SUPPORTS UL/CSA FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive UltraSafe range of Mersen fuse-holders. are finger-safe under IEC standards

More information

Cylindrical fuse-link

Cylindrical fuse-link Cylindrical fuse-link Technical data Rated voltage Rated current Rated frequency Rated breaking capacity Characteristics ody material 00 V AC, 00 V AC, 90 V AC CH 8 - A/00 V CH 0,- A/00 V, 0-3 A/00 V CH

More information

SENTRON SIVACON ALPHA

SENTRON SIVACON ALPHA SENTRON SIVACON ALPHA Low-Voltage Power Distribution and Electrical Installation Technology Catalog Extract LV 10 Edition 10/2018 siemens.com/lowvoltage Related catalogs Low-Voltage Power Distribution

More information

Fuse switch disconnectors

Fuse switch disconnectors SWITCHGEAR RBK Fuse switch disconnectors intended for distribution of electricity and protection of electrical equipment against short-circuits and overloads, with industrial fuse links ENERGY SAFELY SWITCHED

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

Gears & Fuse Gears. IEC General Purpose Fuses DIN Fuses Fuse Switch-disconnectors

Gears & Fuse Gears. IEC General Purpose Fuses DIN Fuses Fuse Switch-disconnectors D0 LINOCUR Switch-Disconnector for NEOZED Fuses 63 A D02 230/400 VAC (440VAC) New ergonomically designed screw caps Switch-disconnector with spring-operated mechanism for automatic connection Locking device

More information

W DATASHEET: MINIATURE CIRCUIT BREAKER (MCB), SERIES AMPARO

W DATASHEET: MINIATURE CIRCUIT BREAKER (MCB), SERIES AMPARO W DATASHEET: MINIATURE CIRCUIT BREAKER (MCB), SERIES AMPARO W SCHRACK-INFO Lift and clamp terminals on both sides Terminal guide for secure connection Terminal cross-section: 1-25mm² Snap-on mounting for

More information

General Purpose IEC Fuses

General Purpose IEC Fuses Line protection fuses gl-gg IEC 60269 parts1, 3 and 3-1 DIN VDE 0636 Parts 10, 30 and 31 Dimensions are stipulated in the following regulations: DIN 49360 D Fuse-links DIN 49515 D Fuse-links DIN 49367

More information

CATALOG. EasyLine XLP Fuse Switch Disconnector poles

CATALOG. EasyLine XLP Fuse Switch Disconnector poles CATALOG EasyLine XLP Fuse Switch Disconnector 1-2-3-4 poles 2 E A S Y L I N E X L P F U S E S W I TC H D I S C O N N E C TO R 1-2 - 3-4 P O L E S Contents 004 005 Introduction EasyLine XLP 006 007 Introduction

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

8WH2 Spring-Loaded Terminals

8WH2 Spring-Loaded Terminals 8WH2 Spring-Loaded Terminals /2 Introduction /3 General data on 8WH /7 8WH through-type terminals 1) /18 8WH hybrid through-type terminals 1) /21 8WH fuse terminals /23 8WH isolating blade terminals /25

More information

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage SENTRON Configuration Manual Edition 10/2015 siemens.com/lowvoltage 2 Introduction LD main control and EMERGENCY-STOP switches up to 250 A 4 Introduction 7 Front mounting 10 Floor mounting 11 Distribution

More information

NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a

NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a NH fuse-links gg 69VAC NH fuse-links gg 69VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions in accordance with DIN 43 62 Live tags Top indicator Lead free contact blades % cadmium

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

Fuse switch disconnectors

Fuse switch disconnectors SWITCHGEAR 62 RBK pro Fuse switch disconnectors designed for distribution of electricity and protection of electrical equipment against short-circuits and overloads with industrial fuse links. ENERGY SAFELY

More information

8WH2 Spring-Loaded Terminals

8WH2 Spring-Loaded Terminals 8WH2 Spring-Loaded Terminals /2 Introduction /3 General data on 8WH /7 8WH through-type terminals 1) /18 8WH hybrid through-type terminals 1) /21 8WH fuse terminals /23 8WH isolating blade terminals /25

More information

Cylindrical fuse-link

Cylindrical fuse-link ylindrical fuse-link Technical data Rated voltage Rated current Rated frequency Rated breaking capacity haracteristics Body material 00 V A, 500 V A, 90 V A H 8-5 A/00 V H 0,5- A/500 V, 0-3 A/00 V H -5

More information

Surge-Trap Pluggable STPT2 Series - 40kA

Surge-Trap Pluggable STPT2 Series - 40kA Surge-Trap Pluggable STPT2 Series - 40kA SURGE PROTECTION FOR POWER LINES DIN-RAIL IEC TYPE 2 / CLASS II FEATURES & BENEFITS Maximum discharge current (8/20μs): 40kA per phase Nominal discharge current

More information

Residual Current Protective Devices / Arc Fault Detection Devices (AFDDs)

Residual Current Protective Devices / Arc Fault Detection Devices (AFDDs) Introduction Overview Devices Page Application Standards Used in / Personnel, material and fire protection, as well as protection against direct contact. SIGRES with active condensation protection for

More information

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories Page 1 of 5 MS132-10 ABB contact for United States of America General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: MS132-10 1SAM350000R1010 4013614400100 MS132-10

More information

Fuse switch-disconnectors

Fuse switch-disconnectors Fuse switch-disconnector FH000 is intended for fuse-links with blade contacts size 000. It enables safe disconnection not only of rated current, but also overcurrent up to octuple rated current. A version

More information

Miniature Circuit-Breakers (MCBs)

Miniature Circuit-Breakers (MCBs) Product Overview Miniature Circuit-Breakers (MCBs) Design Tripping characteristics Rated current I n Rated breaking capacity Power supply company product range 5SP3 E 16 - A Standard product range 5SQ2

More information

NH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a

NH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions in accordance with DIN 43 62 Live tags Top indicator Lead free contact blades % cadmium APPLICATIONS gg: General purpose (protection

More information

BETA Fuses and Fuse Systems

BETA Fuses and Fuse Systems Introduction Overview Application LV HRC fuses are used for installation systems in non-residential, commercial and industrial buildings as well as in the switchboards of power supply companies. Fuses

More information

PANEL PANEL MOUNTING COMPONENTS

PANEL PANEL MOUNTING COMPONENTS PANEL PANEL MOUNTING COMPONENTS For conventional wiring, Wöhner offers a comprehensive range of panel components for fastening to a DIN rail or mounting plate. The fuses and associated connection technology

More information

SCREW-TYPE DISTRIBUTION BLOCKS

SCREW-TYPE DISTRIBUTION BLOCKS SCREW-TYPE DISTRIBUTION BLOCKS PRODUCT INFORMATION CONTA-CONNECT Screw-distributor blocks SVB The SVB screw-type distributor block makes it possible to distribute potential and power in a compact space

More information

Special Purpose Fuses

Special Purpose Fuses Special Purpose Fuses Fuses for DC voltage applications www.eti.si ETI Elektroelement d.d. Obrezija 5, SI - 111 Izlake Slovenija Tel. + 38 03 5 57 570 Faks + 38 03 5 7 077 eti@eti.si NH DC 80 V - Telecom

More information

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved

More information

Vertical fuse disconnects

Vertical fuse disconnects THE NAME FOR SAFETY Vertical fuse disconnects Vertical fuse disconnects Vertical fuse disconnects are designed to receive NH fuse links. Hinged fuse-carriers enable opening and closing operation in electric

More information

Vertical fuse disconnects

Vertical fuse disconnects THE NAME FOR SAFETY Vertical fuse disconnects Vertical fuse disconnects Vertical fuse disconnects are designed to receive NH fuse links. Hinged fusecarriers enable opening and closing operation in electric

More information

Glass fuse 16x5 mm time lag. Number Amp. Number Amp.

Glass fuse 16x5 mm time lag. Number Amp. Number Amp. Fuses Glass Accessoiries for fuses Fuses NDZ Fuses Diazed Fuses Neozed Fuses automatic Screw connection Fuses Knife Fuses plug/in standard and Maxi Fuse links melting plate Fuses porcelain Glass fuse 16x5

More information

3/2 Introduction. Unequipped Distribution Boards (Flat Pack) 3/6 8GK1 surface-mounting distribution boards

3/2 Introduction. Unequipped Distribution Boards (Flat Pack) 3/6 8GK1 surface-mounting distribution boards ALPHA 400 - DIN Wall-Mounted Distribution Boards /2 Introduction Unequipped Distribution Boards (Flat Pack) /6 8GK1 surface-mounting distribution boards Pre-Assembled Unequipped Distribution Boards /7

More information

FUSE BASES NH FUSE BASES 690V 160A 160A

FUSE BASES NH FUSE BASES 690V 160A 160A fuse bases NH NH 14 690V NH 16 ACCESSORIES FOR NH 18 CR 690V NH 20 SECTIONABLE NEUTRAL NH BASES 21 BS FUSE SWITCH DISCONNECTORS 690V NH NH Fuse bases for NH fuse links. For mounting on DIN/EN rail or

More information

SCREW-TYPE DISTRIBUTION BLOCKS

SCREW-TYPE DISTRIBUTION BLOCKS CONTA-CONNECT SCREW-TYPE DISTRIBUTION BLOCKS Our ideas Your advantages CONTA-CONNECT Screw-distributor blocks SVB The SVB screw-type distributor block makes it possible to distribute potential and power

More information

MS General Information Extended Product Type: MS

MS General Information Extended Product Type: MS MS132-1.6 General Information Extended Product Type: MS132-1.6 Product ID: 1SAM350000R1006 EAN: 4013614400063 Catalog Description: MS132-1.6 Manual Motor Starter Long Description: The MS132-1.6 manual

More information

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV Switch Disconnectors Introduction Siemens AG 2010 Overview 3NP5 0 3NP5 2 3NP5 fuse disconnector range 3NP5 4 SENTRON 3NP5 fuse disconnectors are controls for the occasional manual ing/isolating of loads

More information

NB1 Miniature Circuit Breaker

NB1 Miniature Circuit Breaker P-00 Modular DIN Rail Products MCB NB Miniature Circuit Breaker Color coded contact position indicator provides visual indication of the device status and insulation function Magnetic trip elements provide

More information

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC. Page -2 Page -2 AC FUSE HOLDERS Version without indicator: 1P, 1P+N, 2P, 3P, 3P+N Version with indicator: 1P For fuses x38, 14x51 and 22x58mm IEC class gg or am. IEC rated current: 32A, 50A, 0A IEC rated

More information

Fuse switch-disconnectors

Fuse switch-disconnectors Fuse switch-disconnector FH00 is intended fuse-links with blade contacts size 000 and 00. It enables safe disconnection not only of rated current, but also overcurrent up to octuple rated current. A version

More information

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI . Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,

More information

vertical fuse switch disconnectors

vertical fuse switch disconnectors SWITCHGEAR ARS vertical fuse switch disconnectors - touch protection IP 30 from the front - fibre glass extra strenghtened, self extinguishing thermoplastics - double clearance between open contacts -

More information

Fuse holders and fuses

Fuse holders and fuses Modular size for 10x38, 14x51 and 22x58mm fuses Finger safe - IEC IP20 degree of protection against accidental contact with live parts and with sealable cover for operators safety Version with status indicator

More information

3NP1 Fuse Switch Disconnectors up to 630 A

3NP1 Fuse Switch Disconnectors up to 630 A Switch Disconnectors 3NP1 Fuse Switch Disconnectors up to 630 A Introduction Overview All key product features at a glance available for all sizes Connection of circular conductors and laminated conductors

More information

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489 Data Sheet System pro M compact for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU200 M is BB s solution for UL 489 branch circuit protection

More information

The Complete Range. Drawing of the NH Fuse-Switch, 3-pole switching, horizontal design for busbar supply on a 60 mm busbar systems

The Complete Range. Drawing of the NH Fuse-Switch, 3-pole switching, horizontal design for busbar supply on a 60 mm busbar systems The Complete Range Easy mounting onto supporting rails Protection against accidental contact in the standart version Perforated versions for connections Drawing of the NH Fuse-Switch, 3-pole switching,

More information

new NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price

new NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price gg fuselinks 500V (IEC60269 - VDE0636 - DIN43620) with fuse blown indication NH Fuse links gg class with high

More information

Miniature Circuit-Breakers (MCBs)

Miniature Circuit-Breakers (MCBs) Product overview Miniature Circuit-Breakers (MCBs) Design Tripping characteristic Rated currents I n Rated breaking capacity Power supply company product range 5SP3 E 16 - A Standard product range 5SX2

More information

NH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3

NH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3 NH fuse-links gg 4VAC double indicator/live gripping-lugs size,, 1, 2, 3 NH fuse-links gg 4VAC double indicator/live gripping-lugs size,, 1, 2, 3 LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS

More information

Power distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly

Power distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly NH fuse-switch disconnectors, size 000 Version -pole, cable outlet at the top/bottom For the use of fuse inserts to EN 60 - Technical specifications to IEC/EN 60 947-, see chapter -5, page 6 see chapter

More information

W Datasheet: Residual current circuit breaker, series PRIORI, 10kA, Typ B

W Datasheet: Residual current circuit breaker, series PRIORI, 10kA, Typ B W Datasheet: Residual current circuit breaker, series PRIORI, 10kA, Typ B W SCHRACK-INFO All-current sensitive RCCB ( type B, B+ and Bfq) B+ types also meet the requirements of superior fire-protection

More information

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489 2CDC021004S0014 2CDC021046S0014 The miniature circuit breaker SU 200 M is ABB s solution for UL 489 branch

More information

Jtec 10kA Miniature Circuit Breaker

Jtec 10kA Miniature Circuit Breaker EN 60898 Jtec 10kA Miniature Circuit Breaker Techna s JTEC range has been enthusiastically adopted by a diverse range of customers seeking a cost effective 10kA performance. Jtec MCBs are available in

More information

Solid State Relays, 3-phase

Solid State Relays, 3-phase PMA Prozeß- und Maschinen-Automation GmbH Solid State Relays, 3-phase Zero-Point switching, heatsink integrated Main Characteristics: Three-phase controlled Zero switching LED display Various connection

More information

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1 MainswitchSurfacemounting Partno. T0-2-8900/I1/SVB Articleno. 207151 CatalogNo. CT02-8900-I1CRQ Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual

More information

NH-Fuse system Low voltage

NH-Fuse system Low voltage 38103-FER NH-fuses A4-engl 22.10.2003 15:50 Uhr Seite 3 NH-Fuse system Low voltage 38103-FER NH-fuses A4-engl 22.10.2003 14:01 Uhr Seite 2 Utilization NH-fuses gg am gtr NH-fuses Utilization Categories

More information

Vertical fuse disconnects

Vertical fuse disconnects Vertical fuse disconnects Vertical fuse disconnects Vertical fuse disconnects are designed to receive NH fuse links. Hinged fuse-carriers enable opening and closing operation in electric circuits under

More information

Varius SUMMARY OF MODELS

Varius SUMMARY OF MODELS SUMMARY OF MODELS Type 10 14 22 OPT22/OPT20 OPVF10 Rated operating current I e / Rated current I n 32 A / - 63 A / - 125 A / - 63 A / - - / 30 A Rated operating voltage U e / Rated voltage U n AC 690 V

More information

Viking 3 - Screw connection Disconnect terminal blocks

Viking 3 - Screw connection Disconnect terminal blocks 87045 LIMOGES Cedex Telephone: (+33) 05 55 06 87 87 - Fax: (+33) 05 55 06 88 88 Viking 3 - Screw connection 1. General features... 1 2. Range...2 3. Standards... 2 4. Technical features... 3 5. Dimensions...

More information

HelioProtection HP10NH Photovoltaic fuse-links gpv 1000VDC

HelioProtection HP10NH Photovoltaic fuse-links gpv 1000VDC SPECIAL PURPOSE FUSES PHOTOVOLTAIC FUSES FEATURES & BENEFITS Mersen HP10NH photovoltaic (PV) fuse series was engineered and designed specifically for the protection of photovoltaic systems. Helio-Protection

More information

MS25, MST25, MS20, MST20

MS25, MST25, MS20, MST20 Versions: - MS25 with thermal and magnetic releases - MST25 with a thermal release - MS20 - with thermal and magnetic releases for single-phase consumers - MST20 with a thermal for single phase consumers

More information

Electronic overload relays EF205 and EF370

Electronic overload relays EF205 and EF370 Data sheet Electronic overload relays EF205 and EF370 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0 MainswitchSurfacemounting Partno. T0-2-1/I1/SVB-SW Articleno. 207148 IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches

More information

Modular contactor for installation into distribution boards

Modular contactor for installation into distribution boards Modular contactor for installation into distribution boards Description Modular contactors are used for installation in consumer units in dwellings, business premises, hotels, hospitals, shopping centres,

More information

NH Plastic bases. NH Plastic bases IEC NH FUSE BASES FEATURES & BENEFITS APPLICATIONS STANDARDS TECHNICAL DATA OVERVIEW

NH Plastic bases. NH Plastic bases IEC NH FUSE BASES FEATURES & BENEFITS APPLICATIONS STANDARDS TECHNICAL DATA OVERVIEW FUSE HOLDERS, FUSE BASES AND SUPPORTS IEC NH FUSE BASES FEATURES & BENEFITS Polyester insulating bases Silver-plated contacts High-pressure spring contacts Screw or rail mounting Multipolar bases available

More information

Fuse Switch Disconnectors XNH. Fuse Switch Disconnectors XNH... For fuse links NH000 to NH3. Rated operating current of 160, 250, 400 and 630A

Fuse Switch Disconnectors XNH. Fuse Switch Disconnectors XNH... For fuse links NH000 to NH3. Rated operating current of 160, 250, 400 and 630A www.eaton.eu Panel Building Accessories PIFT Plug In Fused Terminal Fuse Disconnectors Thermostats Filters and Fans Terminals Electrical Cabinet Heating Catalogue 2016 Fuse Switch Disconnectors XNH Fuse

More information

Size 00-4a LV HRC fusebases. plates and for direct mounting on busbars. In addition, they serve as bases for LV HRC fuselinks

Size 00-4a LV HRC fusebases. plates and for direct mounting on busbars. In addition, they serve as bases for LV HRC fuselinks Product family fuse-bases Size 00-4a fusebases are suitable for surface mounting on mounting plates and for direct mounting on busbars. In addition, they serve as bases for fuselinks in accordance with

More information

In-line Plug-in Design 3NJ6

In-line Plug-in Design 3NJ6 Contents Page - Outgoing Feeders General 6/2 Structure and Functions inclusive Forms of Internal Separation, Installation of Instruments 6/2 Plug-on Bus System 6/2 Cable Connection Compartment 6/2 Switch-disconnector-fuse

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A fuser_548_a_1_cat fuser_532_a_1_cat fuser_539_a_1_cat FUSERBLOC from 25 to 32 A FUSERBLOC from 630 to 1250 A FUSERBLOC from 32 to 400 A Function FUSERBLOC are manually operated multipolar fuse combination

More information

Protection Equipment. 5/2 Introduction

Protection Equipment. 5/2 Introduction Protection Equipment /2 Introduction SIRIUS 3RV2 Motor Starter Protectors/ Circuit Breakers up to 40 A /6 General data /12 For motor protection /14 For motor protection with overload relay function /1

More information

Technical data. Busbar support 3 7, 5 6, 8 ETIBUSBAR 1 0, 5 BBS-60/4

Technical data. Busbar support 3 7, 5 6, 8 ETIBUSBAR 1 0, 5 BBS-60/4 Busbar support 20 30 BBS-/1 BBS-/3 57 52 29 29 1 5 3 0 1 5 10 2 0 5 3 7, 5 6 0 6 0 6 0 6, 8 12 1 0, 5 7 5 1 2 5 2 4 0 20 30 18 BBS-/4 563 98,5 10 29 93,5 5 29 18 75 180 10,5 6,8 30 30 25 20 52,5 12 BBS-/3-16

More information

NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4

NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4 NH fuse-links am 500-690VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions according to DIN 43 620 Parts 1 to 4 Lead free contact blades 0% cadmium APPLICATIONS am: Partial purpose,

More information

Horizontal fuse disconnects

Horizontal fuse disconnects THE NAME FOR SAFETY Horizontal fuse disconnects Horizontal fuse disconnects Horizontal fuse Disconnects are used in building installations, switchgear and controlgear as well as in power utility networks.

More information

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A Fuse protection fuser_737_a_1_cat.eps fuser_738_a_1_cat.eps The solution for > Motor load break > Protection of industrial processes FUSERBLOC REAR / FRONT connections 3 x 250 A fuser_739_a_1_cat.eps Strong

More information

LV HRC fuse switch-disconnectors

LV HRC fuse switch-disconnectors The 9 series LV HRC fuse switch-disconnectors of the DIN sizes 00-4a are suitable for surface mounting on mounting plates and for direct mounting on busbars. The different sizes are available as 1-pole,

More information

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation Motor-protectivecircuit-breaker,3p,Ir=2.5-4A Partno. PKZM01-4 Articleno. 278482 CatalogNo. XTPB004BC1 Deliveryprogramme Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton

More information

Standardized fuse characteristics

Standardized fuse characteristics Product family "Fuses offer unique advantages compared to other protective devices." Standardized fuse characteristics and high current limitation guarantee easy and reliable coordination between HV HRC

More information

One Source. Fuse monitoring for NH Fuse-Bases or Fuse-Rails

One Source. Fuse monitoring for NH Fuse-Bases or Fuse-Rails One Source Insulator Clamps for devices Fuse monitoring for NH Fuse-Bases or Fuse-Rails Solid links MM: Bild angeben Content NH Replacement Handles 192 NH Solid-Links 192 Fuse-Monitoring with strikers

More information

Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 high voltage contacts Quick and easy assembling Protection class IP68 acc.

Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 high voltage contacts Quick and easy assembling Protection class IP68 acc. Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 high voltage contacts Quick and easy assembling Protection class IP68 acc. DIN EN 60529 General characteristics and technical data Series

More information

Series L9 UL489 Miniature Circuit Breakers

Series L9 UL489 Miniature Circuit Breakers Series L9 UL489 iniature Circuit Breakers Industrial Circuit Breakers for Branch Circuit Protection up to 63 Amps L9 Series B Circuit Breakers Series B L9 UL489 circuit breakers offer new features, expanded

More information

NH fuse-links am 690VAC top indicator/live tags size 4, 4a

NH fuse-links am 690VAC top indicator/live tags size 4, 4a NH fuse-links am 69VAC LOW VOLTAGE IEC FUSES IEC NH FUSE-LINKS FEATURES & BENEFITS Dimensions according to DIN 43 62 parts 1 to 4 Non-isolated gripping lugs Double indicator Lead free contact blades %

More information

Siemens AG Fuse Systems. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens.com/lowvoltage

Siemens AG Fuse Systems. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens.com/lowvoltage Siemens AG 015 Totally Integrated Power SENTRON Configuration Manual Edition /01 siemens.com/lowvoltage Siemens AG 015 Siemens AG 015 Introduction NEOZED fuse systems 8 NEOZED fuse links 15 DIAZED fuse

More information

Miniature Circuit Breaker

Miniature Circuit Breaker Introduction - Miniature Circuit Breaker (MCB) SALIENT FEATURES SALIENT FEATURES Standards MCBs conform to the latest standard IS 8828: 1996/IEC: 898 1995 Mid-Trip Position The Mid trip position of the

More information

Synergy EN product information

Synergy EN product information Synergy EN60947-4-2 product information Rated operational voltages U e 200Vac to 480Vac Rated operational currents I e See Rating Table Rating index See Sizing Guide Rated frequency/frequencies 50-60Hz

More information