Jumper Terminals and Tee Taps. delivery
|
|
- Daisy McDaniel
- 5 years ago
- Views:
Transcription
1 Jumper Terminals and Tee Taps delivery November 017
2 November 017
3 Jumper Terminals & Tee Taps Index Compression/Aluminum JTS... Straight Pad for AAC, AAAC, ACAR & ACSR Conductor JTF Degree Pad for AAC, AAAC, ACAR & ACSR Conductor ORT1... Cable to Pad, Open Run, AAC, AAAC, ACAR & ACSR Conductor ORT1SSAC... Cable to Pad, Open Run, ACSS ORT1STW... Cable to Pad, Open Run, ACSS/TW ORT... Cable to Cable, Open Run, AAC, ALLOY, ACAR AND ACSR Conductors Degree Terminal Alumoweld & HS Steel Straight Terminal Alumoweld & HS Steel November 017
4 November 017
5 Jumper Terminals Compression Straight Pad AAC, AAAC, ACAR and ACSR Conductor Jumper Terminal ALUMINUM JTS Jumper terminals are prefilled with inhibitor. Tongue holes have NMA spacing. Standard hardware includes one aluminum 1/ - 13 bolt, nut and two aluminum washers per.56 diameter hole. Jumper terminals for conductors 1.00 inch diameter or larger are HV rated. Material: Terminal seamless extruded aluminum alloy tube Hardware aluminum alloy IDNTIFICATION: Conductor Type & Diameter Range Part Number, Date Code Length Before Compression 1 Pad Width [].56 Dia [1] Pad Width [] November 017
6 Jumper Terminals Catalog Number JTS07 JTS08 JTS09 JTS10 JTS11 JTS1 JTS13 JTS1 JTS15 JTS16 JTS17 JTS19 JTS0 Outside Diameter Inches () Std Cond / Compact/TW Conductor Range (1) AAC Size Kcmil ACSR Kcmil (Str) ACSR/TW (Typ) (6/7) (18/1) Pad Width Holes Length Inches (mm) Die Size Minimum Press 1.7 () 9. (3) 07CD 1 0. (.19) (18/1) (0/7) 1.7 () (9) 08CD (.7) (T3) (/7) - 77 (/7). (56) (6) 09CD (.36) (T13) - 77 (T13) (6/7) (18/1). (56) (90) 10CD (.9) (T16) (T16) (18/1) (36/1) (307) 11CD (.68) (T13) (T13) (36/1) (5/7) (33) 1CD (.81) (T7) (T16) (30/19) (5/7) (30) 13CD 60. (.99) (T3) (T16) (30/19) - 17 (36/1) (356) 1CD 60.7 (1.) (T13) (T13) (5/19) (5/19) (371) 15CD (1.) (T13) (T13) (5/7) (5/7) (0) 16CD (1.7) (T7) (T7) (5/19)-1868 (68/7).0 (10) (19) 17CD 60.7 (.1) (T13) (T7) (7/7) - 31 (76/19).0 (10) (5) 19CD (.8) (T13) (T8) Product Data and Conductor Size (76/19).0 (10) 18. (67) 0CD (3.) NOT: Conventional (AH Die) jumper terminals in catalog number series 33XXX listed separately. To specify stainless steel hardware add SS to catalog number. xample: JTS1SS (1) Compact AAC and ACSR/TW conductor terminal diameter ranges are the lower of the dual listings. () These terminals also approved for minimum tension applications on AAAC and ACAR conductors within the diameter ranges. November 017
7 Jumper Terminals Compression 15 Pad AAC, AAAC, ACAR and ACSR Conductor Jumper Terminal ALUMINUM JTF Jumper terminals are prefilled with inhibitor. Tongue holes have NMA spacing. Standard hardware includes one aluminum 1/ - 13 bolt, nut and two aluminum washers per.56 diameter hole. Jumper terminals for conductors 1.00 inch diameter or larger are HV rated. Material: Terminal seamless extruded aluminum alloy tube Hardware aluminum alloy IDNTIFICATION: Conductor Type & Diameter Range Part Number, Date Code 15 Length Before Compression Pad Width.56 Dia [] 3 [] [] Pad Width assurance November 017
8 Jumper Terminals Catalog Number JTF07 JTF08 JTF09 JTF10 JTF11 JTF1 JTF13 JTF1 JTF15 JTF16 JTF17 JTF19 JTF0 Outside Diameter Inches () Std Cond / Compact/TW Conductor Range (1) AAC Size Kcmil Product Data and Conductor Size ACSR Kcmil (Str) ACSR/TW (Typ) (6/7) (18/1) Pad Width 1.7 () Length Inches (mm) Die Size Minimum Press 9. (3) 07CD 1 0. (.19) (18/1) (0/7) 1.7 () (9) 08CD (.7) (T3) (/7) - 77 (/7). (56) (6) 09CD (.36) (T13) - 77 (T13) (6/7) (18/1). (56) (90) 10CD (.9) (T16) (T16) (18/1) (36/1) (307) 11CD (.68) (T13) (T13) (36/1) (5/7) (33) 1CD (.81) (T7) (T16) (30/19) (5/7) (30) 13CD 60. (.99) (T3) (T16) (30/19) - 17 (36/1) (356) 1CD 60.7 (1.) (T13) (T13) (5/19) (5/19) (371) 15CD (1.) (T13) (T13) (5/7) (5/7) (0) 16CD (1.7) (T7) (T7) (5/19)-1868 (68/7).0 (10) (19) 17CD 60.7 (.1) (T13) (T7) (7/7) - 31 (76/19).0 (10) (5) 19CD (.8) (T7) (T8) (76/19).0 (10) 18. (67) 0CD (3.) NOT: Conventional (AH Die) jumper terminals in catalog number series 33XXX listed separately. To specify stainless steel hardware add SS to catalog number. xample: JTF09SS (1) Compact AAC and ACSR/TW conductor terminal diameter ranges are the lower of the dual listings. () These terminals also approved for minimum tension applications on AAAC and ACAR conductors within the diameter ranges. November 017
9 Shield Wire Terminals Compression Straight Terminal Alumoweld and HS Steel Shield Wire Terminal ALUMINUM 33 The bore is capped and pad holes have NMA spacing. Standard hardware includes two aluminum 1/ - 13 bolts, nuts and four aluminum washers. Material: Body aluminum alloy Hardware aluminum alloy IDNTIFICATION: Wire Type & Size Part Number, Date Code Length Before Compression.56 Dia [1] 1.1 [7] 5 [] Catalog Number Outside Diameter Inches Shield Wire Data HS Steel Product Data and Wire Size Alumoweld Length Before Compression Die Size Minimum Press /16 7 # 10, 3 # 7 7. (180) 10SH 1.18 (.08) /8 7 # 9, 3 # 6 7. (190) 1SH 60.7 (.1) # 8, 3 # (190) 1SH (.17) /16 7 # (190) 1SH 60.0 (.18) SW / 7 # (00) 16SH (.6) November 017
10 Shield Wire Terminals Compression Straight Terminal Alumoweld and HS Steel Shield Wire Terminal ALUMINUM 30 The bore is capped and pad holes have NMA spacing. Standard hardware includes two aluminum 1/ - 13 bolts, nuts and four aluminum washers. Material: Body aluminum alloy Hardware aluminum alloy IDNTIFICATION: Wire Type & Size Part Number, Date Code Length Before Compression 15º 6.56 Dia [1] [] 1.1 [7] Product Data and Wire Size Catalog Number Outside Diameter Inches Shield Wire Data HS Steel Alumoweld Length Before Compression Die Size Minimum Press 3010SW /16 7 # 10, 3 # (150) 1SH (.08) 3015SW /8 7 # 9, 3 # 6 6. (160) 1SH 60.7 (.1) 3017SW # 8, 3 # 5 6. (160) 1SH (.17) 30130SW /16 7 # (170) 1SH 60.0 (.18) SW / 7 # 6 7. (190) 16SH (.6) November 017
11 Tee Connectors Tee-Taps Compression Cable to Pad Open Run AAC, AAAC, ACAR and ACSR Conductors Pad holes have NMA spacing. Length Before Compression ALUMINUM ORT1 Material: Body aluminum alloy Pad cast aluminum IDNTIFICATION: Conductor Type & Diameter Range Part Number, Date Code Min Flat.56 [1] Dia Holes [] Pad Width [] Min Flat B Pad Width [] Fargo Catalog Number Outside Diameter Conductor Range (1) Pad Details Length AAC Size ACSR Size Bolt Width Kcmil Kcmil (Str) Holes Inches (mm) Before Compression Die Size () Minimum Press ORT ( ) 300, 336., (18/1) (6/7) (6/7).0 (51) 11.3 (87) 07CD (0.37) ORT ( ) 350, 397.5, (18/1) (6/7) (30/7), (18/1).0 (51) 1.7 (33) 08CD (0.8) ORT109 ORT109C ORT110 ORT110C ( ) 50, 77, 500, (/7) (6/7) (30/7), 77 (18/1) (/7) ( ) 556.5, 600, 636, 650 ORT ( ) 700, 715.5, 750 ORT11 ORT11D ORT113 ORT113D ORT11 ORT11D ORT115 ORT115D ORT116 ORT116D ( ) ( ) ( ) ( ) 795, 800, 87.5, 900, (6/7) (30/7), (18/1) (/7) (6/7), 636 (18/1) (36/1) (30/7), 605 (/7) (6/7) (30/19), 636 (18/1) (30/19), 666 (/7) (6/7), (/7) (/7) (6/7) (30/19), 795 (/7) (6/7) (5/7) (5/7), 795 (36/1), 900 (5/7).0 (51).0 (51) 13. (30) 1. (366) 09CD (363) 15.3 (389) 10CD AH (0.61) 1.5 (0.65) 1.7 (0.7) 1.8 (0.78) 16.3 (1) 11CD 60.5 (1.09).0 (10) 1000, , 795 (30/19) 13CD 30AH 900 (5/7), 18.5 (70) 1100, (5/7) (5/7),.0 (10) 19.5 (95) 13CD (36/1) (5/7) 119.5, 100, (30/19), (5/7), 17, (5/7) (5/19), 19.8 (503) (5/7).0 (10) 0.8 (58) , 100, 131, 1500, ( ) 1590, 1600, 1700 Product Data and Wire Size (5/19), 17 (5/7) (5/19), (5/7) (5/19) 131 (5/7) (5/19), (5/7) (5/19), 1590 (5/7).0 (10).0 (10) 17.3 (39) 18.3 (65) 1CD (1.35) 3.3 (1.50) 0.7 (56) 1.7 (551) 1.6 (59).6 (57) (1.57) 3.8 (1.66) 1CD 3AH 60.6 (.00).8 (.09) 15CD 36AH (.0) 5.7 (.8) 16CD 38AH (.66) 6.3 (.7) ORT ( ) 1750, 1800, (5/19) 1780 (8/19), 1869 (68/7).0 (10) 3.5 (597) 17CD (3.0) ORT , 50, (7/7), 057 (76/19), 167 (7/7) 19CD ( ).0 (10) 5. (65) AH (.3) 156 (8/19), 31 (76/19) 19CD 7 NOT: Install with Fargo type UJC or, for lowest resistance connection, type HTJC inhibitor compound. Tees are suitable for HV applications on conductors over 1.0 in (5. mm) O. D. (1) These tee taps also approved application on AAAC and ACAR conductors within the diameter ranges listed. () Hex dies not available for some sleeve & conductor combinations. If no AH die listed for conductor, use only the CD die shown. November 017
12 Tee Connectors Tee-Taps Compression Cable to Pad Open Run ACSS Conductors Tee-taps listed below are rated for use on ACSS conductors when installed with Fargo type HTJC, high-temperature joint compound. Tap pad holes have NMA spacing. Length Before Compression ALUMINUM ORT1SSAC 8 Material: Body aluminum alloy Pad cast aluminum Fargo Catalog Number ORT107SSAC ORT107CSSAC ORT108SSAC ORT108CSSAC ORT109SSAC ORT109CSSAC ORT110SSAC ORT110CSSAC Conductor Range Pad Details Outside Diameter ACSS Size Bolt Width Kcmil (Str) Holes Inches (mm) ( ) 66.8 (18/1) (6/7) (6/7).0 (51) ( ) 336. (18/1) (6/7) (30/7), (18/1).0 (51) ( ) ( ) ORT111SSAC ( ) ORT11SSAC ORT11DSSAC ORT113SSAC ORT113DSSAC ORT11SSAC ORT11DSSAC ORT115SSAC ORT115DSSAC ORT116SSAC ORT116DSSAC IDNTIFICATION: Conductor Type & Diameter Range Part Number, Date Code ( ) ( ) ( ) ( ) ( ) ORT117SSAC ( ) ORT119SSAC ( ) (/7) (6/7) (30/7), 77 (18/1) (/7) 77 (6/7) (30/7), (18/1) (/7) (6/7), 636 (18/1) (36/1) (30/7), 605 (/7) (6/7) (30/19), 636 (18/1) (/7) (6/7) (30/19), 666 (/7) (6/7), (/7) (/7) (6/7) (30/19), 795 (/7) (6/7) (5/7) (5/7), 900 (5/7) 795 (30/19) 795 (30/19), 900 (5/7), 95 (5/7) (5/7), (36/1) (5/7) 95 (30/19), (5/7), 1113 (5/7) (5/19), (5/7) (5/19), 17 (5/7) (5/19), (5/7) (5/19) 131 (5/7) (5/19), (5/7) (5/19), 1590 (5/7) 1590 (5/19), Min Flat.56 [1] Dia Holes Product Data and Conductor Size.0 (51).0 (51) Length Before Compression Die Size (1) Min Press 1.7 (33) 13.7 (38) 07CD (0.1) 0.97 (0.) 13.5 (33) 1.5 (368) 08CD 76AH (0.50) 1. (0.60) 15.6 (396) 16.6 () 09CD (0.68) 1.6 (0.73) 16.3 (1) 17.3 (39) 10CD AH (0.86).0 (0.91) 18.1 (59) 11CD 60.6 (1.18).0 (10).0 (10).0 (10).0 (10).0 (10) [] Pad Width 19.5 (95) 0.5 (51) 1CD (1.50) 3.5 (1.59) 1.3 (51).3 (566). (56) 3.3 (589).0 (610) 5.0 (635) 5.0 (635) 6.0 (660) [] Min Flat 13CD 30AH 13CD Pad Width 60 [] 3.9 (1.77).1 (1.86) 1CD 3AH (.31) 5.3 (.0) 15CD 36AH (.67) 6.1 (.77) 16CD 38AH (3.67) 8.3 (3.76) 1780 (8/19), 1869 (68/7).0 (10) 6.0 (660) 17CD (3.86) 03.5 (7/7), 057 (76/19), 19CD 167 (7/7).0 (10) 8.8 (73) AH (5.13) 156 (8/19), 31 (76/19) 19CD B NOT: Install with Fargo type HTJC inhibitor compound. Tees are suitable for HV applications on conductors over 1.0 in (5. mm) O.D. (1) Hex dies not available for some sleeve and conductor combinations. If no AH die listed for conductor, use only the CD die shown. November 017
13 Tee Connectors Tee-Taps Compression Cable to Pad Open Run ACSS/TW Conductors Tee taps listed below are rated for use on ACSS/ TW conductors when installed with Fargo type HTJC, high-temperature joint compound. Tap pad holes have NMA spacing. Length Before Compression ALUMINUM ORT1STW Material: Body aluminum alloy Pad cast aluminum Fargo Catalog Number ORT107STW ORT107CSTW ORT108STW ORT108CSTW ORT109STW ORT109CSTW ORT110STW ORT110CSTW IDNTIFICATION: Conductor Type & Diameter Range Part Number, Date Code Product Data and Conductor Size ACSS/TW Conductor Range Pad Details Outside Diameter Kcmil Size (Type) Bolt Width Holes ( ) 66.8 (T16).0 (51) ( ) 336. (T16 & T3).0 (51) ( ) (T13 & T16), 77 (T13).0 (51) ( ) 77 (T16 & T3), (T13 & T16), (T16), (T13).0 (51) Length Before Compression Die Size (1) Min Press Size 1.7 (33) 13.7 (38) 07CD (0.1) 0.97 (0.) 13.5 (33) 1.5 (368) 08CD 76AH (0.50) 1. (0.60) 15.6 (398) 16.6 () 09CD (0.68) 1.6 (0.73) 16.3 (1) 17.3 (39) 10CD AH (0.86).0 (0.91) ORT111STW ( ) 636 (T13 & T16) 18.1 (59) 11CD 60.6 (1.18) Min Flat.56 [1] Dia Holes [] Pad Width [] Min Flat B Pad Width [] 9 ORT11STW ORT11DSTW ( ) 76.8 (T13 & T16), 795 (T7, T13 & T16).0 (10) 19.5 (95) 0.5 (51) 1CD (1.50) 3.5 (1.59) ORT113STW ORT113DSTW ORT11STW ORT11DSTW ORT115STW ORT115DSTW ORT116STW ORT116DSTW ( ) ( ) ( ) ( ) ORT117STW ( ) ORT119STW ( ) 795 (T3) 13CD 30AH 1.3 (51) 795 (T3), 900 (T13),.0 (10).3 (566) 95 (T7 & T13), (T16), 966. (T13), (T7) 13CD (T13), 1113 (T7 & T13), 1158 (T7), (T13), (T7) (T13), (T13), 17 (T7 & T13), (T7 & T13), 131 (T7).0 (10).0 (10) 131 (T7 & T13), (T13) (T13), 1590 (T7).0 (10). (56) 3.3 (589).0 (610) 5.0 (635) 5.0 (635) 6.0 (660) (1.77).1 (1.86) 1CD 3AH (.31) 5.3 (.0) 15CD 36AH (.67) 6.1 (.77) 16CD 38AH (3.67) 8.3 (3.76) 1590 (T13), (T7), (T7).0 (10) 6.0 (660) 17CD (3.88) (T13), (T7) 19CD.0 (10) 8.8 (73) AH (5.13) 156 (T8) 19CD NOT: Install with Fargo type HTJC inhibitor compound. Tees are suitable for HV applications on conductors over 1.0 in (5. mm) O.D. (1) Hex dies not available for some sleeve and conductor combinations. If no AH die listed for conductor, use only the CD die shown. November 017
14 Tee Connectors Tee-Taps Compression Cable to Cable Open Run AAC, Alloy, ACAR and ACSR Conductors ALUMINUM ORT Tap barrel is prefilled with inhibitor. Material: Body aluminum alloy Tap extruded aluminum alloy tube Run Length Before Compression IDNTIFICATION: RUN Conductor Type & Diameter Range Part Number, Date Code TAP Conductor Diameter Range Branch Length Before Compression CATALOG NO. ORT XX YY TAP COD RUN COD PRODUCT SRIS 10 Product Data and Conductor Size Outside Diameter Conductor Range (1) AAC Size Kcmil ACSR Size Kcmil (Str) Run or Tap Code Run Length Before Tap Die Size Minimum Press Size ( ) 300, 336., (18/1) (6/7) (6/7) (7) 3.6 ( 91) 07CD (0.3) ( ) 350, 397.5, (6/7), 336. (18/1) (6/7) (30/7), (18/1) (311).1 (105) 08CD 76AH (0.3) ( ) 50, 77, 500, (/7) (6/7) (30/7), 77 (18/1) (/7) (350).6 (118) 09CD (0.9) ( ) 556.5, 600, 636, (6/7) (30/7), (18/1) (/7) (6/7) 636 (18/1) (36/1) (363) 5. (131) 10CD AH (0.63) ( ) 700, 715, (30/7), 605 (/7) (6/7) (30/19) 636 (/7) (6/7) (30/19) 666 (/7) (6/7) (/7) (00) 5.7 (1) 11CD (0.86) ( ) 795, 800, 87.5, 900, (6/7) (30/19), 795 (/7) (6/7) (5/7) 795 (5/7) 795 (36/1) 900 (5/7) (36) 6. (157) 1CD 60.0 (1.09) ( ) 1000, (30/19) 1100, (30/19), 900 (5/7), 95 (5/7) (5/7) (36/1) (5/7) (73) 6.7 (170) 13CD 30AH 13CD (1.36) ( ) 119.5, 100, 150, 17, (30/19), 1113 (5/7) (5/19), (5/7), 17 (36/1) (509) 7. (183) 1CD 3AH (1.73) November 017
15 Tee Connectors Outside Diameter ( ) Conductor Range (1) AAC Size Kcmil , 100, 131, 1500, Product Data and Conductor Size (continued) ACSR Size Kcmil (Str) (5/19), 17 (5/7) (5/19), (5/7) (5/19) Run or Tap Code Run Length Before Tap Die Size Minimum Press Size (56) 7.7 (197) 15CD 36AH (.1) , 1600, (5/7) (5/19), (5/7) (5/19), 1590 (5/7) (51) 8. (10) 16CD 38AH (.1) , 1800, (5/19), (575) 8.8 (3) 17CD 0AH (.86) , 50, (7/7), 057 (76/19) 19CD 167 (7/7) (63) 9.8 (9) AH (.0) 156 (8/19), 31 (76/19) 19CD NOT: Standard Hex dies not available for some sleeve and conductor combinations. If no AH die listed for conductor, use only the CD die shown. Install with Fargo type UJC or, for lowest resistance connection, type HTJC inhibitor compound. Tees are suitable for HV applications on conductors larger than 1.0 in O.D. xample: ORT111 would be the catalog number for a ACSR 795 (6/7) Run with an ACSR 636 (/7) Tap. (1) These tee taps also approved application on AAAC and ACAR conductors within the diameter ranges listed. 11 November 017
16 November 017
DISTRIBUTION CONNECTORS SECTION DF COMPRESSION TERMINALS. Aluminum Compression Lugs Aluminum Bi-Metal Pin Terminals Copper Compression Lugs
DISTRIBUTION CONNECTORS COMPRESSION TERMINALS Aluminum Compression Lugs Aluminum Bi-Metal Pin Terminals Copper Compression Lugs SECTION VERSAtile ALUMINUM COMPRESSION TERMINAL TYPE VCEL For use with either
More informationConductor Protection. results
Conductor Protection results Conductor Protection Index Dampers 607... Vibration Damper 4R Stockbridge...1 Armor Rods AP8... Aluminum Armor Rods...6 APS... alvanized Steel Armor Rods...8 APAS... AluminumClad
More informationDISTRIBUTION PRODUCTS
DISTRIBUTION PRODUCTS INDEX SECTION DI OTHER DISTRIBUTION SERIES DESCRIPTION PAGE WILDLIFE PROTECTORS CC101 / CC170.. CUT-OUT COVER, ONE PIECE WILDLIFE PROTECTOR... DI-3 GS... ONE PIECE WILDLIFE PROTECTOR...
More informationSUBMERSIBLE SECONDARY CONNECTORS SSBC350-4LI. Cond. Range H W L
SUBMERSIBLE SECONDARY CONNECTORS -1- Index TYPE SSBC350-L (Wide-Port Spacing) Rubber Insulated Secondary Connectors SURE-SEAL RUS Approved User friendly wide-port spacing (50% more room for cable training).
More informationStandard Compression Dead End for ACSR and ACSS Conductor CAUTION: ACSR Dead Ends Cannot Be Used on ACSS HT Conductor
INS-ACA089 Installation Instructions Standard Compression Dead End for ACSR and ACSS Conductor CAUTION: ACSR Dead Ends Cannot Be Used on ACSS HT Conductor 1. Mark the conductor a distance of 3 /4 the length
More informationGSA Series Formed Wire Suspension
GSA Series Formed Wire Suspension Formed Wire Suspension Unit AFL is a renowned manufacturer of aluminum conductor accessories, manufacturing numerous products for the electric utility industry since the
More informationKcmil. Mass kg/each. Tel:
Catalog Number Conductor Size Kcmil Conductor Strand Alu Dead End Alu Jumper Steel Dead End Approximative Mass kg/each Cicame Alu Die Cicame Steel Die CSA Alu Die CSA Steel Die TD6N TD7N TD8N TD9N TDN
More informationSPIRAL VIBRATION DAMPERS FOR AAC, AAAC, ACSR, COPPER, SC/AC & SC/GZ CONDUCTORS. Part Number
SPIRAL VIBRATION DAMPERS FOR AAC, AAAC, ACSR, COPPER, SC/AC & SC/GZ CONDUCTORS Made from high impact, UV resistant, polyvinyl chloride (PVC), they are non-corrosive and do not abrade the conductor or require
More informationTRANSMISSION PRODUCTS
TRANSMISSION PRODUCTS INDEX Deadends bolted/aluminum AR1/AR2... QUADRANT STRAIN CLAMP...TA-4 PG/DE... QUADRANT STRAIN CLAMP...TA-3 SD... QUADRANT STRAIN CLAMP...TA-1 SDT2... DOUBLE GROOVE STRAIN CLAMP...TA-2
More informationSlack Span Dead-end GENERAL RECOMMENDATIONS NOMENCLATURE (440)
NOMENCLATURE Material Helical Leg Section: Aluminum covered steel. An aluminum alloy version is available for corrosive environment. Contact PLP. Crossover Marks: Indicates starting point for application
More informationArmor Rods. Armor Rods NOMENCLATURE GENERAL RECOMMENDATIONS
Transmission: Section 1 NOMENCLATURE Single Support and Double Support : Identified by S and D appearing in the length column on the catalog page. Should the maximum distance between tied supports exceed
More informationCONTENTS OVERHEAD SLEEVES AND LUGS
CONTENTS OVERHEAD SLEEVES AND LUGS SECTION 5 SECTION 5 OVERHEAD CONDUCTOR SLEEVES & LUGS..................45 NON TENSION SLEEVES.......................................46 FULL TENSION SLEEVES TYPE A...............................46
More informationNumber Tube I.P.S. Rod Size or O.D. Range Cable H J W
TYPE GAR D-28 FENCE POST GROUNDING CONNECTOR For Parallel or 90 Copper Cable Connection To Rod or Pipe with the Same Connector High copper alloy ground connector for joining a range of cable, parallel
More information026-2 : 1996 CEB STANDARD
026-2 : 1996 CEB STANDARD COMPRESSION CONNECTORS & TERMINATIONS FOR OVERHEAD LINE CONDUCTORS CEYLON ELECTRICITY BOARD SRI LANKA CONTENTS 1. Scope 2 2. System Parameters 2 3. Service Conditions 2 4. Applicable
More informationSuspension Clamps. performance
Suspension Clamps performance Suspension Clamps Index olted/aluminum CFS... Corona Free Clamp for Use With Armor Rods...-3 CFS (ONG)... Corona Free Clamp for Use Without Armor Rods...-4 CFSHT... Corona
More informationARMOR-GRIP Suspension: Double
: Double For Line Angles Between 30 and 60 ACSR, All-Aluminum, Aluminum Alloy, AWAC Compacted All-Aluminum Compacted ACSR, ACSS, ACSS/TW Range AGS s AGS AGS s & Min. Max. Nominal Conductor Size s Per Set
More informationPRODUCTS FOR THE RAIL AND UTILITY INDUSTRY
PRODUCTS FOR THE RAIL AND UTILITY INDUSTRY connectorproducts.com 1300 John Tipton Blvd. Pennsauken, NJ 08110 Phone: 856.829.9190 Fax: 856.829.9195 Catalog IX.1 American Design American Made Our success
More informationOur overhead products go above and beyond all others. QUICK REFERENCE. Overhead Connectors. & Covers. Overview
Overview QUICK REFERENCE Overhead Connectors & Covers page(s) Our overhead products go above and beyond all others. We have plenty of overhead connectors. From transformer eyebolts and stirrup connectors
More informationTHERMOLIGN Products for 3M Aluminum Conductor Composite Reinforced (3M ACCR)
Products for 3M Aluminum Conductor Composite Reinforced (3M ACCR) July 2015 History of Hardware at PLP Preformed Line Products has been involved with the design, testing and production of hardware and
More informationPLP Compression Dead-end & Jumper Terminal for ACSR & ACSS Conductors
MARCH 2017 PLP Compression Dead-end & Jumper Terminal for ACSR & ACSS Conductors Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED
More informationCompression Hardware Series For ACSR Conductors
Compression Hardware Series For ACSR Conductors PAGE 4 5 6 7 CONTENTS Compression Dead-end - CMPDE Compression Jumper Terminal - CMPTM Compression Dead-end assembly - cmpdej compression splice assembly
More informationSUBMERSIBLE SECONDARY CONNECTORS
SUBMERSIBE SECONDARY CONNECTORS TYPE SSBC350- (Wide-Port Spacing) Rubber Insulated Secondary Connectors SURE-SEA RUS Approved User friendly wide-port spacing (50% more room for cable training). Multiple
More informationEasy-On II Terminations
Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables, concentric neutral, metal tape shielded or wire shielded cables without need for additional
More informationCompression Connectors
Compression s Compression H- s Type WR Wide Range luminum s O and D Die Seven Program Pass the requirements of NSI C9. Seven Program provides superior connector performance, lower connection Field-proven
More informationPSC Terminations. Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables.
Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables. Sizes are available for all shielded cables in voltage classes from 15kV through 46kV.
More informationBonding & Grounding. Telecommunications Main Ground Bars. Telecommunications Main Ground Bar Kits
PhysicalSupport.D 1/21/08 2:10 PM Page 121 GB4X12TMGB GB4X20TMGB GB4X12TMGBKIT Telecommunications Main Ground Bars and Kits Manufactured of 1/4 thick electrolytic tough pitch 110 alloy copper bar. Includes
More information477-kcmil, 3M Brand Composite Conductor Compression Dead End Evaluation Mechanical Holding Strength
3M 477-kcmil, 3M Brand Composite Conductor Compression Dead End Evaluation Mechanical Holding Strength Principal Investigator: Dr. Kamal Amin Reviewed by: Dr. Colin McCullough Date of Report: June 1, 2003
More informationREADY REFERENCE GUIDE
ENERGY /// ENERGY REAY REFERENCE GUIE REAY REFERENCE GUIE Generation istribution Transmission Who is TE? We are a reliable provider of energy solutions for any environment. With a focus on employee expertise
More informationDISTRIBUTION CONNECTORS
SECTION ANDERSON VERSA-CRIMP BATTERY POWERED ACSR CUTTING Model VCACSRCCBP is used to cut ACSR, aluminum, and copper conductors up to 1.50". Cuts standard guy wire and ground rod sizes up to 5/8". This
More informationPower System Analysis I TRANSMISSION LINE PARAMETERS
Power System Analysis I TRANSMISSION LINE PARAMETERS Components of Overhead Lines Transmission Line Parameters An overhead transmission line consists of conductors, insulators, support structures, and,
More informationOLS U T I L I T Y S E G M E N T
BURNDY TOOLS UTILITY SEGMENT BURNDY Tools exemplify both reliability and engineering knowledge unsurpassed in the industry. BURNDY.COM 3 BURNDY TOOL SERVICE GETS IT DONE! GET IT FIXED Tools repaired at
More information04.02 SPLICES AUTOMATIC SPLICE INSTALLATION ONE PIECE COMPRESSION SPLICE SPLICING SLEEVES AND DIE SIZES FOR ALUMINUM AND COPPER CONDUCTORS
4. GENERAL INSTALLATION GUIDE FOR CONNECTORS 4. INSTALLATION GUIDE FOR CONNECTORS 4.4 ELECTRIC CONTACT INHIBITORS 4.6 CONDUCTOR CLEANING TOOLS 4.8 4. SPLICES AUTOMATIC SPLICE INSTALLATION AUTOMATIC SPLICE
More informationAluminum Mechanical Lugs
luminum Mechanical ugs MNI INUSTRI ONNTORS One- and Two-onductor luminum ugs Suitable for use with either copper or aluminum conductors Manufactured from high strength 6061-T6 aluminum alloy lectroplated
More informationSuper-Shield Parts List & Pricing. Date: 06/01/12
Super-Shield Parts List & Pricing Date: 06/01/12 To Order Call: 519-227-4323 PAGE 2 Friction Super-Shield Flat Style Friction Super-Shield Friction Drive G 60 Flat Style Track. Complete with Torsion Mount
More informationTRANSMISSION LINE REPAIR MANUAL. A guidebook for the inspection and repair of damaged or worn conductors
TRANSMISSION LINE REPAIR MANUAL A guidebook for the inspection and repair of damaged or worn conductors August 2017 PREFACE Since 1947 Preformed Line Products has been a recognized leader in the business
More informationConnector Installation Guide Compression and Mechanical Connectors
Connector Installation Guide Compression and Mechanical Connectors Typical Cross Section of a Compression Connector Before Installation Before compression, a typical cross section of cable consists of
More informationInsulated Street and Highway Lighting Mechanical Connectors Insulated connectors for above-ground applications.
Lighting Mechanical Connectors Insulated Lighting Mechanical Connectors Insulated connectors for above-ground applications. Rubber Insulation Ensures an insulated connection. Models with Street Light Connectors
More informationChapter 1. Connectors & Fittings for Railways
Chapter Connectors & Fittings for Railways Current Carrying Catenary Dropper Component N Messenger Bz Cable length from L Component N 3 Component N 2 Contact Wire SNCF approved This dropper provides a
More informationAluminum Conductor Composite Reinforced Installation Guidelines and Maintenance
3 Aluminum Conductor Composite Reinforced Installation Guidelines and Maintenance 1 Contents Installation Guidelines and Maintenance for ACCR Aluminum Conductor Composite Reinforced 1. Introduction 4 2.
More informationCold Shrink Silicone Rubber Termination QT-III 7672-S-8-JCN
3 Cold Shrink Silicone Rubber Termination QT-III 7672-S-8-JCN Instructions IEEE Std. No. 48-1996 Class 1 Termination 69 kv Class 350 kv BIL IEC 60840 72,5 kv Kit Contents: 1 Silicone Rubber Lug Seal Insulator
More informationTYPE BILT DISCONNECT SWITCHES
TYPE BILT DISCONNECT SWITCHES OUTDOOR HOOKSTICK OPERTED (DISTRIBUTION CLSS) For sectionalizing and tap applications 7.5KV through 38KV 900 -- 40,000 momentary Furnished with hooks for loadbreak tool Used
More informationCTN U-TYPE DIE COLOR INDEX QTY 7/374 8/346 11/375 12/ /298 18/324 19/470 20/299 22/472 24/473 CTN U-TYPE DIE COLOR INDEX QTY
PAGE 2 PEEP HOLE STANDARD BARREL COPPER LUGS Allows inspection of the termination to assure complete cable insertion GL SERIES One-Hole 32000 GL 80 32002 GL 84 3999 GL 0 32004 GL 4 3200 GL 5 32003 GL 38
More information477-kcmil, 3M Brand Composite Conductor Compression Dead End Evaluation Mechanical Holding Strength
3M 477-kcmil, 3M Brand Composite Conductor Compression Dead End Evaluation Mechanical Holding Strength Principal Investigator: Dr. Kamal Amin Reviewed by: Dr. Colin McCullough Date of Report: June 1, 2003
More informationCONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING NON-NETWORK SYSTEMS
CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY 10003 DISTRIBUTION ENGINEERING DEPARTMENT NON-NETWORK SYSTEMS SPECIFICATION EO-100186 REVISION #10 MAY 2007 EFFECTIVE DATE MAY
More informationPRODUCTS FOR THE RAIL AND UTILITY INDUSTRY
PRODUCTS FOR THE RAIL AND UTILITY INDUSTRY connectorproducts.com 1300 John Tipton Blvd. Pennsauken, NJ 08110 Phone: 856.829.9190 Fax: 856.829.9195 CATALOG IX.1 American Design American Made Our success
More informationRail Fittings. Top Fittings Handrail Fittings Handrails Track Fittings Hinge Fittings Head Screws
5 Top Fittings Handrail Fittings Handrails Track Fittings Hinge Fittings Head Screws Connectors Stanchion & End Fittings Elbow Tees Rail Tees Canvas Fasteners Rail Fittings 5 Rail Fittings BIMINI FITTINGS
More informationFORD METER BOX CURB BOXES SECTION GA
FORD METER BOX CURB BOXES SECTION GA Ford Curb Box Numbering System E= Cast Iron Curb Box 4 = 1" Dia. Upper Section 5 = 1-1/4" Dia. Upper Section 6 = 1-1/2" Dia. Upper Section 1 = Single Piece Lid (Erie
More informationNon-insulated terminals : 8, 14, 22, 38, 60, 70, 80, 100, 150, 180, 200, 325 mm 2
12A Non-insulated terminals : 8, 14, 22, 38, 60, 70, 80, 100, 150, 180, 200, 325 mm 2 Maximum input pressure: 700 bar Oil volume required : 90 cc Output force : 226 kn 280 (L) mm 7.5 kg Steel carrying
More informationBolted Dead End for OPGW
Bolted Dead End for OPGW The AFL Dead End is a full tension termination for Optical Ground Wire cable. Breakaway head bolts are used to apply a precise gripping force to hold the cable without affecting
More information3M Cold Shrink QT-lll Silicone Rubber Skirted Termination Kit 7692-S-4, 7693-S-4, 7694-S-4, 7695-S-4, 7696-S-4
3M Cold Shrink QT-lll Silicone Rubber Skirted Termination Kit 7692-S-4, 7693-S-4, 7694-S-4, 7695-S-4, 7696-S-4 With High-K Stress Relief For Tape Shielded, Wire Shielded and UniShield Cable Instructions
More informationAccepts BEKU type dies Up to 150 mm 2 Cu lug. The EP-50H was designed to accept dies for BEKU type mechanical tool widely used in European countries.
EP-50H Accepts BEKU type dies Up to 150 mm 2 Cu lug Ram stroke : 15 mm Oil volume required : 18 cc Force at die face : 52 kn 250 (L) mm 1.6 kg Steel carrying case with die tray EP-50H Example of dies The
More informationUnderground Distribution
Aluminum Flood-Seal TM Mechanical Connectors Save outlet space These connectors feature the Sweetheart TM outlet configuration that nests two equal-sized service cables from #6 to 2/0 or two different-sized
More informationGround Wire Size. 1/2 in /4 in. 2 in /2 in. 3-1/2 in TB. 4 in. 5 in. #4 4/0 AWG 3906-TB
lamps Waterpipe Ground lamps Waterpipe Ground lamps Waterpipe Ground lamps 2-T Ground Wire Size Water Pipe Size 1/2 in., 3/4 in., 1 or rebar 4-10 3-T 1-1/4 in., 1-1/2 in. or 2 in. #6, #4, #2 WG 4 2-1/2
More informationTHIS MATERIAL IS MEANT TO BE USED ALONG WITH OUR CATALOG IT IS NOT A SUBSTITUTE FOR THE CATALOG
THIS MATERIAL IS MEANT TO BE USED ALONG WITH OUR CATALOG IT IS NOT A SUBSTITUTE FOR THE CATALOG COMPANY OVERVIEW Since 1970, we have been pioneering new developments in heater technology and providing
More informationCold Shrink Silicone Rubber Termination QT-III (With High-K Stress Relief)
Cold Shrink Silicone Rubber Termination QT-III (With High-K Stress Relief) Instruction Sheet IEEE Std. No. 48 1990 Class 1 Termination 5/8.7 kv Class 95 kv BIL Kit Contents: 3 Hi K, Tracking Resistant,
More information3M Brand Composite Conductor Connector Current Cycle Qualification Test for 795 kcmil Compression Connectors
3M Brand Composite Conductor Connector Current Cycle Qualification Test for 7 kcmil Compression Connectors 3M Company Purchase Orders 0000797063 and 0000866974 NEETRAC Project Number: 03-071 September,
More informationCONNECTORS AND FITTINGS
Industry photo: should be a the same image as larger industry photo. Either a different crop or different angle. Human photo. Can be environmental/ documentaty style or portrait of engineer. Human photo.
More information3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit With High-K Stress Relief
3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit With High-K Stress Relief 7642-S-2, 7642-S-2(L) For Jacketed Concentric Neutral (JCN) and Concentric Neutral (CN) Cable Instructions IEEE Std.
More informationELECTRICAL ITEMS Cables : Specification: XLPE Insulated Power Cable All Cables Cables PVC Insulated Cables Fire Resistant Cables Aluminium Cables
ELECTRICAL ITEMS Cables : Specification: XLPE Insulated Power Cable 0.6 / 1kV XLPE Insulated Unarmoured Cables 0.6 / 1kV XLPE Insulated Armoured Cables 1.8 / 3kV XLPE Insulated Armoured Cables 3.6 / 6kV
More informationCTN QTY 7/374 8/346 11/375 12/ /298 18/324 19/470 20/299 22/472 24/473. Two-Hole NEMA CTN QTY
PAGE 2 PEEP HOLE STANDARD BARREL COPPER LUGS Allows inspection of the termination to assure complete cable insertion GL SERIES One-Hole 2000 2002 998 999 2004 200 200 2005 200 2008 207 2007 2009 200 20
More information11. CABLE SPECIFICATIONS 5kV, 15kV, AND 35kV RUBBER OR PLASTIC INSULATED CABLE
11. CABLE SPECIFICATIONS 5kV, 15kV, AND 35kV RUBBER OR PLASTIC INSULATED CABLE 11.1 GENERAL Only single conductor cables as described in this section are acceptable for connection to PECO Energy Company
More informationItem Code Description Unit Qty Total
UNDP ELECTRICITY SECTOR NORTHERN GOVERNORATES Phase XI Item Code Description Unit Qty Total 04-02-00001 Service Pole - 6m, 75mm dia GS Pipe 11250 04-02-00002 9m Tubular Steel Poles complete with all Accessories
More information3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit
3M Cold Shrink QTIII Silicone Rubber Skirted Termination Kit With HighK Stress Relief 3M Cold Shrink QTIII Silicone Rubber Skirted Termination Kit With HighK Stress Relief For Jacketed Concentric Neutral
More information3M Cold Shrink QT-III Silicone Rubber Indoor Tubular Termination Kit
3M Cold Shrink QT-III Silicone Rubber Indoor Tubular Termination Kit With High-K Stress Relief For Tape Shield, Wire Shield and UniShield Cable 7622-T-110, 7624-T-110, 7625-T-110, 7626-T-110 Instructions
More information3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit
3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit With High-K Stress Relief For Tape Shielded, Wire Shielded and UniShield Cable 7685-S-8 Instructions IEEE Std. No. 48 Class 1 Termination 35
More information3M Cold Shrink QT-III Silicone Rubber Indoor Termination Kits With High-K Stress Relief
3M Cold Shrink QT-III Silicone Rubber Indoor Termination Kits With High-K Stress Relief For Tape Shield, Wire Shield and UniShield Cable 7621-T-95, 7622-T-95, 7624-T-95, 7625-T-95 Instructions IEEE Std.
More informationSpecifications LINEAR LED MINI. Series CONTINUOUS LINEAR SUSPENDED SYSTEM. GlowSTX GSA. GSA Ordering Example: GSA-05L-9030-LN-048-BB.
LINEAR LED MINI Suspension Cable Key Slot 23.62 (600) 2.24 (57) 35.43 (900) 1.02 (26) 024 47.24 (1200) 70.87 (1800) Extruded Housing Acrylic Diffuser 036 LENGTH CHART 048 94.48 (2400) LED Strip 072 096
More informationProduct Catalog. Rev. 612 r1
Product Catalog Rev. 612 r1 PIPE FITTINGS CONDUIT FITTINGS PRODUCT CATALOG Pipe Nipples Welded and Seamless Carbon Steel 2 Pipe Nipples Welded and Seamless Stainless Steel 3 Pipe Nipples End Finishes 4
More informationAluminum Conductor Composite Reinforced Installation Guidelines and Maintenance
Aluminum Conductor Composite Reinforced Installation Guidelines and Maintenance 1 Contents Installation Guidelines and Maintenance for 3M ACCR Aluminum Conductor Composite Reinforced 1. Introduction.4
More informationSERIES 4300 TC/TSC/TCZ MOTORS
FILE : 6043.137 DATE: July 7, 2010 SUPERSEDES: 6043.137 DATE: June 24, 2010 PARTS LIST SERIES 4300 DESIGN TC/TSC/TCZ MOTORS VERTICAL IN-LINE SPLIT COUPLER "DBL" DESIGNATION - GROUPS 25 TO 51 TS and TSC
More informationHigh Voltage Joints and Terminations up to 72,5 kv 145 kv
High Voltage Joints and Terminations up to 72,5 kv 145 kv 3M Cold Shrink Termination Kits QT-III and Joint Kits are designed to provide high reliability and save you time and money. They install quickly
More informationPINS & BUSHINGS METRIC
PINS & BUSHINGS METRIC PINS & BUSHINGS METRIC CONTENTS PAGE NUMBER General Information 1 Plain & Ball Bearing Guide Posts Press Fit Guide Posts 2 Demountable Guide Posts 4 Automotive Straight Guide Posts
More informationPoles - General Unguyed Single Phase Composite Poles Poles - General Unguyed Three Phase Composite Poles
Standard Description 2 4 2 Poles - General Unguyed Single Phase Composite Poles 2 4 3 Poles - General Unguyed Three Phase Composite Poles 3 3 Structural Elements - Design Limits 3 1 1 Configurations -
More informationflowconme Types of Fittings Available Wall Thickness Sch 5 - Sch 160 (Sch 5s - Sch 160s) Others available upon special request
FITTINGS Overview Types of Fittings Available 45, 9 Elbows, 18 Returns (Short & Long Radius) Tees & Crosses (equal & reducing), Reducers (concentric & eccentric), Caps, Stud Ends, Weldolets, Outlets, Laterals
More informationRockStar HighPower. Contents. RockStar HighPower Introduction C.2 C.1
ontents Introduction.2 HighPower 250 A.4 4000 V 250 A 1 4 poles HighPower 550 A.10 4000 V 550 A 1 3 poles.1 Introduction Uncompromising power in clever and safe packaging. The modular high-current connector
More informationDisc Valve Hydraulic Motors 2000 Series
Disc Valve Hydraulic Motors 10.2014 inspired hydraulics. Änderungen und Druckfehler vorbehalten 10.2014 EN EATON_Motoren english Highlights Port A Features Three zone design for longer life and true bi-directionality.
More informationCATENARY ACCESSORIES INSTRUCTIONS. Power Management. Quick Connect Voltage Separation Box AY-QCVSB. Sheet 5. Suspension Accessories
CATENARY ACCESSORIES INSTRUCTIONS Quick Connect Jumper Cord AY-QC7P6-X Sheet 2 Quick Connectors AY-QC7SET Sheet 3 3/32" Stainless Steel Cable AY-CBL3/32-50 Power Cord AY-P6-50 Power Cord Ties AY-WT-100
More information3M Cold Shrink QT-lll Silicone Rubber Indoor Tubular Termination Kits With High-K Stress Relief
3M Cold Shrink QTlll Silicone Rubber Indoor Tubular Termination Kits With HighK Stress Relief For Tape Shield, Wire Shield and UniShield Cable 7693T150, 7695T150, 7696T150 Instructions IEEE Std. No. 48
More informationPRODUCT CATALOG SHUTTLE PRO
PRODUCT CATALOG SHUTTLE PRO Contents Custom Conveyor Drives Shuttle Pro-100LP...4 Shuttle Pro-200HS...5 Standard Conveyor Drives Shuttle Pro-150...6 Shuttle Pro-250...7 Shuttle Pro-500...8 Shuttle Pro-1000...9
More informationMGO Thermocouples. Controls. Connection Head. Connection Head. Thermowells. Junction Fittings. Connectors Connection Heads.
Connection Head Type J, K, T and E Grounded Ungrounded Exposed Sheath Materials 304 Stainless Steel 316 Stainless Steel Inconel 600 Standard Aluminum Aluminum Flip Top Cast Iron/Aluminum 316 Stainless
More informationALUMINUM DISTRIBUTING, INC S.W. 2nd Ave. Ft. Lauderdale, FL Table of Contents
Table of Contents Page 2.........Equal & Unequal Angle Structural & Architectural Page 3.......................Flat Bar Structural Page 4.....................Flat Bar Architectural Page 5..... U Channel,
More informationHow the choice of transmission conductor can reduce greenhouse gas emissions.
How the choice of transmission conductor can reduce greenhouse gas emissions. What is the scope of the impact? Complete conversion of the US grid to efficient conductor would eliminate 44 million metric
More informationSTRAIN LINK STICK ROLLER LINK STICK ADJUSTABLE STRAIN POLES SPIRAL LINK STICK TRANSMISSION TOOLS
172 Phone: 800-323-6606 Fax: 847-488-1285 www.hilineco.com STRAIN LINK STICK Used as insulation between rope blocks and a hot line wire grip For deadend structures and running corners Attached to conductor
More informationTERMINATION ENCLOSURE OPTIONS
TERMINATION ENCLOSURE OPTIONS Add suffix: R - Reverse Stagger the Bus Bars (to run cable in from the top) CU - Copper NEMA Mount Bus Bars C - Plastisol Covers for Bus Bars DF - Dead Fronts T - Tin Plated
More informationIllustrated Parts List for VMAC System V Ford F250-F350 Triton 5.4 L 3-valve (with 3 bolt crank pulley)
Illustrated Parts List for VMAC System V900092 2008 Ford F250-F350 Triton 5.4 L 3-valve (with 3 bolt crank pulley) System V900102 2010-2008 Ford F250-F350 Triton 5.4 L 3-valve (with center bolt crank pulley)
More informationInstallation Instructions for LED Timing Light
Daytona Sensors LLC Engine Controls and Instrumentation Systems Installation Instructions for CAUTION: CAREFULLY READ INSTRUCTIONS BEFORE PROCEEDING OVERVIEW The P/N 120001 includes a versatile controller
More information3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kits
3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kits With High Ampacity Ground Connection and High-K Stress Relief For Tape Shield, Wire-Over-Tape Shield and Longitudinally Corrugated (LC) Shield
More informationUnderground Distribution
Aluminum Universal Quick Disconnect Transformer Connectors The EZ Mount connector is used on padmount distribution transformers that have a 5/8 in. or 1 in. secondary bushing stud one mounting hole accepts
More informationDisc Valve Hydraulic Motors 4000 Compact Series
Disc Valve Hydraulic Motors 10.2014 inspired hydraulics. Änderungen und Druckfehler vorbehalten 10.2014 EN EATON_Motoren english Port B Port A Features Shuttle Valve with Back- Pressure Relief Valve Highlights
More information230 kv Aluminum Welded Couplers TYPE or Straight Adapter Tube To Cable
TYPE 14700 Straight Adapter Tube To Cable Adapter is designed to make inline connection between pipe and stranded cable. Cable is puddle welded to connector; connector is then welded to tube. Not recommended
More informationPRODUCTS FOR UNDERGROUND RESIDENTIAL DISTRIBUTION SYSTEMS
PRODUCTS FOR UNDERGROUND RESIDENTIAL DISTRIBUTION SYSTEMS For over 70 years, BURNDY has pioneered and produced economical, dependable connectors and protective devices for urban underground distribution
More informationSMS Solid Stainless Cylinders
SMS Solid Stainless Cylinders Space Saving and Conventional Lengths Pneumatic to 200 PSI Hydraulic 400 to 500 PSI Non shock /8,, 2, 3 Bore 300 Series Stainless Exterior Assures Aesthetics and Function
More informationModel 802 Center Mount Adapter For New Holland 9030 & TV140 Bi-Directional Tractors PARTS CATALOG
Model 802 Center Mount Adapter For New Holland 9030 & TV140 Bi-Directional Tractors 1 PARTS CATALOG TABLE OF CONTENTS Frame & Tractor Linkage...2,3 Header Linkage & Float Group...4,5 Header Drive Hydraulics
More informationTOTAL PIPING SOLUTIONS, INC. TRIPLE-TAP
TOTAL PIPING SOLUTIONS, INC. TRIPLE-TAP Extended Range Stainless Steel Push Plug Line Stop Tapping Sleeve Technical Specifications Controlled Document: ENGTS-05/120417 December 2017 TRIPLE TAP Extended
More informationApril 7, Dear Mr. Nicholson,
Products for Power Utilities and Mass Transit PO Box 2516 5 Surrey Lane Cinnaminson, NJ 08077 T (856) 829-9190 F (856) 829-9195 www.connectorproducts.com April 7, 2009 Mr. Norris Nicholson, Chair Technical
More informationB T T T 2.11 MY29-11 (1) 4/0 AWG - MY29-11 (1) W30VT (2) U30RT (2) 300 kcmil 150 W30VT (2) YA30L-2TC W30RT (2) U28ART (2)
URNDY TWO HOLE HYLUG CODE CONDUCTOR STANDARD ARREL (Continued) T T T Fig. 1 Fig. 2 Fig. 3 Conductor Installation Tooling Stud Stud Figure Mechanical Hydraulic Wire Fig *** Hole Hole Tongue Dimensions Dieless
More information2300/2320. MORTISE LOCKS AND HANDLESET ACCESSORIES (Keepers, Spacers, Adapters and Bumpers)
HANDLES & LOCKSETS MORTISE LOCK APPLICATIONS 2300/2320 Truth Hardware realizes that each profile in the marketplace may require its own particular hardware component due to the variety of mounting applications
More informationQuick Facts LED DIRECTIONAL FIXTURES
TYPE CATALOG # PROJECT NOTES Optional Long Shroud LED DIRECTIONAL FIXTURES dcrest-13 12.3"/31.2 cm Unique inside and out. Crest s curvilinear, organic shape reflects its coastal design inspiration. Crest
More information3M Cold Shrink QT-II Silicone Rubber Indoor Termination Kits
3M Cold Shrink QT-II Silicone Rubber Indoor Termination Kits With High-K Stress Relief For Tape Shield, Wire Shield and UniShield Instructions IEEE Std. No. 48 Class 1 Termination 8 kv Class, 95 kv BIL:
More informationHeavy Duty Copper Battery Terminals
Heavy Duty Copper Battery Terminals Constructed of 131 contact copper to provide high conductivity. Raised characters to ensure legibility of important information regarding cable size, post type, and
More information