Conductor Protection. results

Size: px
Start display at page:

Download "Conductor Protection. results"

Transcription

1 Conductor Protection results

2 Conductor Protection Index Dampers Vibration Damper 4R Stockbridge...1 Armor Rods AP8... Aluminum Armor Rods...6 APS... alvanized Steel Armor Rods...8 APAS... AluminumClad Steel Armor Rods...9 Line uards PL5... Aluminum Line uards...10 Protector Rods PR5... Aluminum Protector Rods...12 Cross Reference Armor Rods, Line uards & Protector Rods...13

3 Dampers Vibration Damper 4R Stockbridge Fargo 4R vibration dampers effectively prevent fatigue damage to conductor and static wires caused by windinduced aeolian vibration. The 4R concept improves on the design of the basic Stockbridge damper, significantly increasing the efficiency of converting windinduced energy into heat. The improved design employs unequal weights on messengers of unequal length. This configuration doubles the number of resonant peaks from two generated by the oldstyle Stockbridge damper to four in the improved Fargo 4R. These additional resonant peaks create an envelope of dynamic response that protects the conductor through the entire range of dangerous vibration frequencies. To assure maximum performance, Fargo utilizes a sophisticated computer simulation whose development has been verified by decades of testing and field measurements. This computer model identifies the optimum damper placement on the span. Fargo 4R Vibration Damper System Provides You... Maximum Protection From Wind Induced Conductor Bending Strain The fourresonant peaks include two separate cantilever response modes and two separate rotational response modes of the weight and messenger cable. These peaks also provide maximum energy dissipation to reduce strain over the entire spectrum of dangerous wind velocities. Wide frequency response range optimizes protection of your system Large 19 strand wire and tight strand lay dissipate energy more efficiently Press fit permanent weight attachment technique assures longterm performance Contoured surfaces prevent corona discharge Permanently Secured Weights Tuning Fork Open Weight Design Hotdipped alvanized Iron Large Weight Long Moment Arm Aluminum Vise Clamp Tight Strand Lay alvanized 19wire Steel Messenger Cable Short Moment Arm Hotdipped alvanized Iron Small Weight Comprehensive Application Program for Optimum Performance Provides precise selection and placement through our proprietary computer simulation Computer program based on a mathematical model verified by decades of laboratory testing and field vibration measurements Precisely identifies the vibration performance characteristics of transmission lines Determines dangerous tension levels for existing or proposed spans Identifies the frequency range, tension level and span lengths requiring damper protection Identifies proper damper placement for required vibration energy dissipation Results of the above analysis for conductors and shield wires are available online at: Fargo 4R Damper Application Software Contoured Surfaces 1 See the Reference Materials section of this catalog for a detailed program description.

4 Dampers Vibration Damper 4R Stockbridge Messenger Cable: Materials and stranding are selected to obtain the best energy absorption characteristics. The galvanized steel messenger is manufactured to rigid engineering standards. Fargo 4R vibration dampers effectively prevent fatigue damage to conductor and static wires caused by windinduced aeolian vibration. Weights: Uniquely shaped so that the resonant peaks are effectively distributed over the desired frequency range. All weights are given a corrosionresistant finish and have smooth surfaces and rounded edges to eliminate possible corona discharge. C Clamp: The bolted clamp permits easy installation on a wide range of conductor sizes. Aluminum clamping bolt ensures that damper clamp remains tight as conductor temperature changes with current load cycling. B A Product Data 2 Damper Catalog Number (1) Bare Conductor/Cable Diameter Range (2) in. (mm) ( ) ( ) ( ) ( ) ( ) Conductor/Cable Dia. Clamp Over Armor Bolt Rods Range (2) Torque in. (mm) ftlb ( ) ( ) ( ) ( ) ( ) Dimensions inches (mm) A B C Weight Each lb (kg) 11.1 (282) 16.1 (409) 16.1 (409) 20.0 (508) 20.0 (508) 21.9 (556) 21.9 (556) 24.0 (610) 24.0 (610) 2.38 (60) 2.69 (68) 2.91 (74) 2.91 (74) 3.20 (81) 3.78 (96) 4.20 (107) 5.92 (150) 6.30 (160) 1.75 (44) 1.75 (44) 2.26 (57) 2.26 (57) 2.26 (57) 2.82 (72) 2.82 (72) 3.54 (90) 3.54 (90) 2.8 (1.3) 4.8 (2.2) 5.0 (2.3) 9.0 (4.1) 9.4 (4.3) 15.7 (7.1) 16.0 (7.3) 22.0 (10) 22.5 (10.2) Std Pkg Qty (1) To specify Torque Head/Break Away bolt option, add suffix O to catalog number. (2) Recommended conductor/cable size range limits. Physical clamp range may be slightly larger.

5 Dampers 4R Damper Installation Instructions Spacing Deadend Spacing Suspension Clamp Spacing Suspension Clamp with Armor Rods Spacing 3 Formed Wire Suspension NOTE: Dampers shall be located from the center of the damper clamp to either the dead end or the suspension support as shown above. The orientation of the damper weights along the conductor is optional. For convenience, orient the damper such that the clamp bolt head faces the installer. When only one damper is required per conductor per span, it can be installed at either span extremity when the support hardware is identical. When support hardware differs, place the damper at the suspension structure. When two dampers are required per conductor per span, the preferred placement is one at each span extremity.

6 Armor Rods & Line uards Industry Competitive Price, quality & lead time Look, feel & function ACSR/ACSS; ACSR/ACSS TW; AAC, AAAC; ACAR Production EHV rated, made to order 4 Inventory available for popular sizes Sample orders welcomed Product Specs Aluminum Alloy Right Hand Lay Ball Ends Chamfered Ends < Add E Suffix for EHV Rod End Add D Prefix for Double Supported Length (For rod diameters < 0.25 only)

7 Armor Rods & Line uards Materials: Rods manufactured from either aluminum covered steel, aluminum alloy or galvanized steel Color code and center mark establishes alignment of rods during application and identifies conductor size Identification tag identifies catalog number and conductor details Industry Knowledge: Armor Rods and Line uards have overlapping purpose to protect conductors from fatiguedamage by providing a stiffening support for suspended conductors. They also protect from abrasiondamage at attachment points by providing a buffer between the conductor and the clamping connector. They are both made up of sets of individual rods of the same diameter. When installed, the set of individual rods grip rigidly onto their respective conductors. Once each rod of the respective set has been installed, the set should evenly enclose the conductor along the length of the rods. Physically, the line guard sets are shorter in length and the individual rods are smaller in diameter. The application for line guards is typically found on light transmission lines with shorter spans, smaller conductor sizes and lower voltages. Armor Rods are recommended for applications where the conductor is clamped or suspended with bolted type connectors. Product Offerings:* Aluminum Armor Rods Aluminum Line uards Aluminum Protector Rods alvanized Steel Rods AlumoWeld Steel Rods 250 C for respective suspension clamp & conductor application* Application O.D. = (Rod O.D. X 2) + Conductor O.D. Armor Rods 1. Fargo Armor Rods are intended to protect conductors from stress and damage which can be caused by a bend, compression, abrasion or arc over. They are also designed to repair conductors which have sustained < 50% outer strand damage.* 2. Armor Rods should be considered as minimum protection for clamp style supports or suspension hardware for spans > 300 feet. 3. Armor Rods are designed to provide an extra degree of protection to the conductor at support points, not act as vibration dampers. In areas where vibration is suspected or known to occur, the use of Fargo 4R Dampers is recommended. eneral Recommendations Line uards 1. Fargo Line uards are intended to provide an extra degree of protection for the conductor against abrasion and arc over. They are also designed to repair conductors which have sustained < 25% outer strand damage.* 2. Line uards should be considered as minimum protection for handtied spans 300 feet in urban areas with no history of vibration. 3. Line uards should be considered as a cost saving alternate to Armor Rods when applicable. Note: HPS Distribution Ties are recommended as an improvement over Line uards and hand ties, providing a stronger and more uniform tie. 5 *The degree of protection required is dependent upon line design, tension, temperature, and wind conditions. Contact HPS Connectors Business Unit for specific recommendations.

8 Conductor Protection Armor Rods For use on stranded aluminum and aluminum composite conductors, including hightemperature conductor designs. (4) ALUMINUM AP8 Material: aluminum alloy 6 Catalog Number AP8114 DAP8114 AP8115 DAP8115 AP8116 DAP8116 AP8117 DAP8117 AP8118 DAP8118 AP8119 DA08119 AP8120 DAP8120 AP8121 DAP8121 AP8122 DAP8122 AP8123 DAP8123 AP8124 DAP8124 AP8125 DAP8125 AP8126 DAP8126 AP8127 DAP8127 AP8128 DAP8128 AP8129 DAP8129 AP8130 DAP8130 AP (18.8) AP (19.9) AP (20.7) AP (21.5) AP (23.1) AP (23.6) NOTES: (1) Righthand lay standard. Product Data and Conductor Size Conductor Dia. Nominal Conductor Size Applied Rod Rods Range In. (mm) (AW or KCMIL) Length Dia. Per Sets Per Wt. Per (in.) (in.) Set Color (lbs.) Code Min. Max. ACSR/ACSS AAC, AAAC (7.8) (8.3) #2 (6/1) 44 56(D) Red (8.3) (8.8) # (D) Blue (8.8) (9.3) #1 (6/1) 48 60(D) reen (9.3) (9.9) 1/ (D) Black (9.9) (10.5) 1/0 (6/1) 52 64(D) Yellow (10.5) (11.1) 2/ (D) Brown (11.1) (11.8) 2/0 (6/1) 54 66(D) Blue (11.8) (12.4) 3/ (D) reen (12.5) (13.2) 3/0 (6/1) 56 68(D) Orange (13.3) (14.0) 4/ (D) Black (14.0) (14.9) 4/0 (6/1) (D) Red (14.9) (15.4) (D) Black (15.4) (16.0) (18/1) 64 76(D) Purple (16.0) (16.6) (26/7) 64 76(D) Yellow (16.7) (17.2) (D) Brown (17.3) (17.9) (18/1) 68 80(D) Blue (17.9) (18.8) (26/7) (D) reen (19.9) (18/1) Orange (20.7) (26/7) 477, Purple (21.5) Red (23.0) 477 (26/7) Blue (23.6) (26/7) reen (24.8) (30/7) 605 (26/7) White (2) For aluminum conductor types & sizes not listed above, select rod set based on dia. range to accomodate conductor. (3) Applied O.D. of conductor with rods, for suspension clamp selection, equals conductor diameter plus two times rod dia. (4) Maximum conductor temperature limits vary with suspension clamp designs. See catalog Reference Data secton for guidelines.

9 Conductor Protection Armor Rods For use on stranded aluminum and aluminumcomposite conductors, including hightemperature conductor designs.(4) ALUMINUM AP8 For EHV applications, add suffix E to catalog numbers to Specify. Example AP8146E Material: aluminum alloy Catalog Number AP (24.8) AP (25.8) AP (26.3) AP (27.1) AP (27.9) AP (29.0) AP (29.5) AP (30.7) AP (32.3) AP (33.7) AP (35.3) AP (36.6) AP (38.3) AP (40.1) AP (42.0) AP (43.9) AP (46.0) NOTES: (1) Righthand lay standard. (2) For aluminum conductor types & sizes not listed above, select rod set based on dia. range to accomodate conductor. (3) Applied O.D. of conductor with rods, for suspension clamp selection, equals conductor diameter plus two times rod dia. (4) Maximum conductor temperature limits vary with suspension clamp designs. See catalog Reference Data secton for guidelines. Conductor Dia. Range In. (mm) Nominal Conductor Size (AW or KCMIL) Min. Max. ACSR/ACSS AAC, AAAC (25.8) Applied Length (in.) Rod Dia. (in.) Rods Per Set Sets Per Wt. Per (lbs.) Color Code 636 (24/7) (26/7) 666 (24/7) (26/7) Yellow (26.3) (30/19) Brown (27.0) (26/7) 795 (45/7) Blue (27.9) 795 (24/7) reen (28.9) 795 (26/7) Orange (29.5) 954 (36/1) Purple (30.7) (32.2) (33.7) (35.3) (36.6) 954 (45/7) (54.7) (45/7) Red (54/7) 1113 (45/7) Black 1113 (54/19) (45/7) White (54/19) /7 (54/19) (45/7) Yellow (54/19) 1434 (45/7) Brown (38.3) 1590 (45/7) Blue (40.1) 1590 (54/19) reen (41.9) 1780 (84/19) Orange (43.9) (72/7) Purple (45.9) Product Data and Conductor Size 2167 (72/7) 2156 (84/19) Red (48.2) 2515 (76/19) Black 7

10 Conductor Protection Armor Rods For use on galvanized, strandedsteel cables with lefthand lay. Typical application is on transmission line overhead shield wires. STEEL APS Material: galvanized steel Catalog Number APS (7.8) APS (8.8) APS (10.5) APS (12.5) NOTES: Cable Dia. Range In. (mm) Min. Max. (1) Lefthand lay standard. Nominal Cable Diameter (in.) Product Data Applied Length (in.) (2) Applied O.D. of conductor with rods, for suspension clamp selection, equals conductor diameter plus two times rod dia. (3) alvanized steel armor rods may be suitable for application on other cable types, Consult factory for specific information. Rod Dia. (in.) Rods Per Set Sets Per Wt. Per (lbs.) Color Code (8.3) 5/ Black (9.5) 3/ Orange (11.1) 7/ reen (13.2) 1/ Blue 8

11 Conductor Protection Armor Rods For use on Alumoweld (aluminumclad, strandedsteel) cables with lefthand lay. Typical application is on transmission line overhead shield wires. STEEL APAS Material: aluminumclad steel Catalog Number APAS0710 DAPAS0710 APAS0079 DAPAS0079 APAS0078 DAPAS0078 APAS018M DAPAS018M APAS0077 DAPAS0077 APAS0076 DAPAS0076 APAS0075 DAPAS0075 Cable Dia. Range In. (mm) Min. Max (7.5) (8.5) (9.5) (10.4) (10.8) (12.1) (13.6) NOMINAL CABLE SIZE INCHES, AWSTR M(UTS klb) Product Data Applied Length (in.) Rod Dia. (in.) Rods Per Set Sets Per Wt. Per (lbs.) Color Code (8.0) 5/16, 7#10, 3#7, 10M 46 58(D) Black (8.9) 7#9, 3#6, 12.5M 50 62(D) Yellow (10.0) 3/8, 7#8, 3#5, 16M 50 62(D) Orange (10.8) 18M 54 66(D) Black (11.4) 7/16, 7#7, 20M 56 68(D) reen (12.8) 1/2, 7# (D) Blue (14.4) 9/16, 7# (D) Yellow NOTES: (1) Lefthand lay standard. (2) Applied O.D. of conductor with rods, for suspension clamp selection, equals conductor diameter plus two times rod dia. (3) Alumoweld is a registered trademark of the Copperweld Co. 9

12 Conductor Protection Line uards For use on stranded aluminum and aluminum composite conductors, including hightemperature conductor designs. (4) ALUMINUM PL5 Material: aluminum alloy 10 Catalog Number PL5130 DPL5130 PL5131 DPL5131 PL5132 DPL5132 PL5133 DPL5133 PL5134 DPL5134 PL5135 DPL5135 PL5136 DPL5136 PL5137 DPL5137 PL5138 DPL5138 PL5139 DPL5139 PL5140 DPL5140 PL5141 DPL5141 PL5142 DPL5142 PL5143 DPL5143 PL5144 DPL5144 PL5145 DPL5145 PL5146 DPL5146 PL5147 DPL5147 PL5148 DPL5148 PL5149 DPL5149 PL5150 DPL5150 PL5151 DPL5151 Product Data and Conductor Size Conductor Dia. Nominal Conductor Size Applied Rod Rods Range In. (mm) (AW or KCMIL) Length Dia. Per Sets Per Wt. Per (in.) (in.) Set Color (lbs.) Code Min. Max. ACSR/ACSS AAC, AAAC (7.4) (7.8) # (D) Purple (7.8) (8.3) #2 (6/1) # (D) Red (8.3) (8.8) # (D) Blue (8.8) (9.3) #1 (6/1) 23 35(D) reen (9.3) (9.9) 1/ (D) Black (9.9) (10.5) 1/0 (6/1) 1/ (D) Yellow (10.5) (11.1) 2/ (D) Brown (11.1) (11.8) 2/0 (6/1) 27 39(D) Blue (11.8) (12.4) 3/ (D) reen (12.5) (13.2) 3/0 (6/1) (D) Orange (13.3) (14.0) 4/ (D) Black (14.0) (14.9) 4/0 (6/1) (D) Red (14.9) (15.4) (D) Black (15.4) (16.0) (18/1) (D) White (16.0) (16.6) (26/7) (D) Yellow (16.7) (17.2) (D) Brown (17.3) (17.9) (18/1) (D) Blue (17.9) (18.8) (26/7) (D) reen (18.8) (19.9) (18/1) (26/7) (D) Orange (20.1) (21.3) (30/7) 477 (18/1) (D) Purple (21.4) (22.8) 477 (26/7) (30/7) 556.5, (D) Blue (22.8) (24.2) (26/7) (30/7) 636 (18/1) (D) reen NOTES: (1) Righthand lay standard. (2) For aluminum conductor types & sizes not listed above, select rod set based on dia. range to accomodate conductor. (3) Applied O.D. of conductor with rods, for suspension clamp selection, equals conductor diameter plus two times rod dia. (4) Maximum conductor temperature limits vary with suspension clamp designs. See catalog Reference Data secton for guidelines.

13 Conductor Protection Line uards Line uards for conductors 1.0 inch diameter or larger are available for EHV application. Add suffix E to catalog number to specify. Example PL5155E ALUMINUM PL5 Catalog Number PL5152 DPL5152 PL5153 DPL5153 PL5154 DPL5154 PL5155 DPL5155 PL5156 DPL5156 PL5157 DPL5157 PL5158 DPL5158 PL5159 DPL5159 PL5160 DPL5160 PL5161 DPL5161 PL5162 DPL5162 PL5163 DPL5163 NOTES: (1) Righthand lay standard. Conductor Dia. Nominal Conductor Size Applied Rod Rods Range In. (mm) (AW or KCMIL) Length Dia. Per Sets Per Wt. Per (in.) (in.) Set Color (lbs.) Code Min. Max. ACSR/ACSS AAC, AAAC (24.3) (25.0) 605 (26/7) 636 (24/7) (D) White (25.1) (25.8) 636 (26/7) 666 (24/7) (26/7) (D) Yellow (25.8) (27.0) 636 (30/19) 715 (26/7) 795 (45/7) (D) Brown (27.1) (27.9) (30/19) 795 (54/7) 874.5, (D) reen (27.9) (29.3) 795 (26/7) (30/19) (D) Orange (29.3) (30.7) 954 (45/7) (54/7) (D) Purple (30/19) (30.7) (32.2) (45/7) (54/7) 1113 (45/7) 1113, (D) Black (32.2) (33.7) (35.3) (36.6) (38.3) (33.7) (35.3) Product Data and Conductor Size (continued) 1113 (54/19) (45/7) (D) White (54/19) 1272 (45/7) (54/19) (45/7) , (D) Yellow (36.6) (54/19) 1431 (45/7) (D) Brown (38.3) 1431 (54/19) 1590 (45/7) 1590, (D) Blue (40.0) 1590 (54/19) (D) reen (2) For aluminum conductor types & sizes not listed above, select rod set based on dia. range to accomodate conductor. (3) Applied O.D. of conductor with rods, for suspension clamp selection, equals conductor diameter plus two times rod dia. (4) Maximum conductor temperature limits vary with suspension clamp designs. See catalog Reference Data secton for guidelines. 11

14 Conductor Protection Protector Rods Primary application as a mechanical reinforcement layer for mounting dampers or other devices on ACSS conductors or OPW cables where suspension support reinforcing rods are not available to mount damper or device. ALUMINUM PR5 For EHV applications, add suffix E to catalog numbers to Specify. Example PR5158E 12 Catalog Number PR (12.1) PR (13.6) PR (14.9) PR (15.7) PR (17.0) PR (18.4) PR (20.8) PR (22.8) PR (24.3) PR (25.9) PR (27.1) PR (27.9) PR (30.0) PR (33.0) PR (36.0) PR (39.2) PR5164 Conductor / OPW Dia. Range In. (mm) Nominal Conductor Size (AW or KCMIL) Min. Max. ACSS ACSS/TW (42.8) Applied Length (in.) Rod Dia. (in.) Rods Per Set Sets Per Wt. Per (lbs.) (13.5) Blue Color Code (14.9) reen (15.7) Orange (16.9) (26/7) (30/7) Purple (18.3) (26/7) (17/7) T Red (20.7) (26/7) (30/7) 477 (18/7) T (18/7) T Black (22.8) 477 (26/7) (30/7) 477 (16/7) T (20/7) T White (24.2) (26/7) (30/7) 636 (20/7) T Yellow (25.9) (27.0) 636 (24/7) (26/7) (30/19) 666 (24/7) (26/7) 715 (24/7) (26/7) 795 (45/7) 795 (21/7) T (20/7) T Brown 795 (22/19) T (33/7) T Blue (27.9) 795 (24/7) (54/7) 954 (21/7) T reen (26/7) (30/19) (33/7) T7 (30.0) 954 (45/7) (21/7) T Orange 1113 (33/7) T (33.0) (35.9) (39.2) (42.8) 954 (54/7) (30/19) (45/7) (54/7) 1113 (45/7) (54/19) (45/7) (54/19) 1272 (45/7) (54/19) (45/7) (54/19) 1431 (45/7) (54/19) 1590 (45/7 Product Data and Conductor Size 1113 (39/19) T (39/19) T (33/7) T7 (39/19) T (33/7) T Purple (39/19) T (36/7) T Blue 1590 (42/19) T (38/19) T Yellow 1590 (54/19) 1780 (84/19) 2156 (64/19) T Brown 1.84 (46.7) 2156 (84/19) Blue NOTES: (1) Righthand lay standard. (2) For conductor/cable sizes not listed above, select rod set based on cable dia. range. (3) Applied O.D. of conductor/cable with rods equals cable diameter plus two times rod diameter. (4) Maximum conductor temperature limits vary with suspension clamp designs. Consult factory for information.

15 Cross Reference: Armor Rods, Line uards & Protector Rods 13 results

16 Armor Rods Aluminum Product Data and Conductor Size Conductor Dia. In. (mm) Nominal Conductor Size (AW or kcmil) HPS PLP DULMISON HELICAL Min. Max. ACSR/ACSS ACSR/ACSS TW AAC, AAAC ACAR (7.8) (8.3) #2 6/1 AP8114 AR0114 AAR0785 AAR (8.3) (8.8) #1 AP8115 AR0115 AAR0830 AAR (8.8) (9.3) #1 6/1 AP8116 AR0116 AAR0880 AAR (9.3) (9.9) 1/0 AP8117 AR0117 AAR0930 AAR (9.9) (10.5) 1/0 6/1 AP8118 AR0118 AAR0990 AAR (10.5) (11.1) 2/0 AP8119 AR0119 AAR1050 AAR (11.1) (11.8) 2/0 6/1 AP8120 AR0120 AAR1110 AAR (11.8) (12.4) 3/0 AP8121 AR0121 AAR1180 AAR (12.5) (13.2) 3/0 6/1 AP8122 AR0122 AAR1245 AAR (13.3) (14.0) 4/0 AP8123 AR0123 AAR1325 AAR (14.0) (14.9) 4/0 6/1 250 AP8124 AR0124 AAR1400 AAR (14.9) (15.4) T AP8125 AR0125 AAR1490 AAR (15.4) (16.0) /1 AP8126 AR0126 AAR1540 AAR (16.0) (16.6) /7 AP8127 AR0127 AAR1605 AAR (16.7) (17.2) T AP8128 AR0128 AAR1665 AAR (17.3) (17.9) / T23 AP8129 AR0129 AAR1725 AAR (17.9) (18.8) / T AP8130 AR0130 AAR1790 AAR (18.8) (19.9) /1 477 T13 AP8131 AR0131 AAR1880 AAR (19.9) (20.7) /7 477 T16 477, AP8132 AR0132 AAR1990 AAR (20.7) (21.5) 477 T T13 AP8133 AR0133 AAR2070 AAR537

17 Armor Rods Aluminum Product Data and Conductor Size (continued) Conductor Dia. In. (mm) Nominal Conductor Size (AW or kcmil) Min. Max. ACSR/ACSS ACSR/ACSS TW AAC, AAAC ACAR HPS PLP DULMISON HELICAL (21.5) (23.0) 480 5/ T T AP8134 AR0134 AAR2150 AAR (23.1) (23.6) /7 636 T T AP8135 AR0135 AAR2305 AAR (23.6) (24.8) / / AP8136 AR0136 AAR2360 AAR (24.8) (25.8) /7 26/ /7 26/ T T13, T AP8137 AP8137E (25.8) (26.3) / AP8138 AP8138E (26.3) (27.0) / /7 964 T AP8139 AP8139E (27.1) (27.9) /7 964 T13 AP8140 AP8140E (27.9) (28.9) / T T AP8141 AP8141E (29.0) (29.5) / T7 AP8142 AP8142E (29.5) (30.7) / / (30.7) (32.2) / / (32.3) (33.7) / / (33.7) (35.3) / /7 54/ / (35.3) (36.6) / / T7, T T T T7, T T T AP8143 AP8143E AP8144 AP8144E T T AP8145 AP8145E T T AP8146 AP8146E 1590 T T AP8147 AP8147E (36.6) (38.3) / T T AP8163 AP8163E (38.3) (40.1) / T AP8164 AP8164E (40.1) (41.9) / T AP8165 AP8165E (42.0) (43.9) /7 AP8166 AP8166E (43.9) (45.9) / / T AP8167 AP8167E (46.0) (48.2) / AP8168 AP8168E AR0137 AR0500 AR0138 AR0501 AR0139 AR0502 AR0140 AR0503 AR0141 AR0504 AR0142 AR0505 AR0143 AR0506 AR0144 AR0507 AR0145 AR0508 AR0146 AR0509 AR0147 AR0510 AR0163 AR0511 AR0164 AR0512 AR0165 AR0513 AR0166 AR0514 AR0167 AR0516 AR0168 AR0517 AAR2480 AAR2480E AAR2585 AAR2585E AAR2630 AAR2630E AAR2705 AAR2705E AAR2790 AAR2790E AAR2895 AAR2895E AAR2950 AAR2950E AAR3070 AAR3070E AAR3225 AAR3225E AAR3375 AAR3375E AAR3535 AAR3535E AAR3660 AAR3660E AAR3835 AAR3835E AAR4010 AAR4010E AAR4195 AAR4195E AAR4390 AAR4390E AAR4595 AAR4595E AAR541 AAR542 AAR543 AAR544 AAR545 AAR546 AAR547 AAR548 AAR549 AAR550 AAR551 AAR552 AAR553 AAR554 AAR555 AAR556 AAR557 15

18 Armor Rods Alumunum, Double Suspension Product Data and Conductor Size Conductor Dia. In. (mm) Nominal Conductor Size (AW or kcmil) HPS PLP DULMISON HELICAL Min. Max. ACSR/ACSS ACSR/ACSS TW AAC, AAAC ACAR (7.8) (8.3) #2 6/1 DAP8114 AR0314 DAAR0785 AAR (8.3) (8.8) #1 DAP8115 AR0315 DAAR0830 AAR (8.8) (9.3) #1 6/1 DAP8116 AR0316 DAAR0880 AAR (9.3) (9.9) 1/0 DAP8117 AR0317 DAAR0930 AAR (9.9) (10.5) 1/0 6/1 DAP8118 AR0318 DAAR0990 AAR (10.5) (11.1) 2/0 DAP8119 AR0319 DAAR1050 AAR (11.1) (11.8) 2/0 6/1 DAP8120 AR0320 DAAR1110 AAR (11.8) (12.4) 3/0 DAP8121 AR0321 DAAR1180 AAR (12.5) (13.2) 3/0 6/1 DAP8122 AR0322 DAAR1245 AAR (13.3) (14.0) 4/0 DAP8123 AR0323 DAAR1325 AAR (14.0) (14.9) 4/0 6/1 250 DAP8124 AR0324 DAAR1400 AAR (14.9) (15.4) T DAP8125 AR0325 DAAR1490 AAR (15.4) (16.0) /1 DAP8126 AR0326 DAAR1540 AAR (16.0) (16.6) /7 DAP8127 AR0327 DAAR1605 AAR (16.7) (17.2) T DAP8128 AR0328 DAAR1665 AAR (17.3) (17.9) 303 5/ T23 DAP8129 AR0329 DAAR1725 AAR (17.9) (18.8) / T DAP8130 AR0342 DAAR1790 AAR634

19 Armor Rods alvanized Steel Product Data and Conductor Size Conductor Dia. In. (mm) HS & EHS Cable HPS PLP DULMISON HELICAL Min. Max (7.8) (8.3) 5/16" APS0516 AR1128 SAR0785 AR (8.8) (9.5) 3/8" APS0038 AR1130 SAR0880 AR (10.5) (11.1) 7/16" APS0716 AR1133 SAR1050 AR (12.5) (13.2) 1/2" APS0012 AR1139 SAR1245 AR534 Armor Rods AlumunumClad Steel (Alumoweld ) Product Data and Conductor Size Conductor Dia. In. (mm) HS & EHS Cable HPS PLP DULMISON HELICAL Min. Max (7.5) (8.0) 5/16", 7#10, 3#7, 10M APAS0710 AR2124 AWAR0750 AWAR (8.5) (8.9) 7#9, 3#6, 12.5M APAS0079 AR2126 AWAR0850 AWAR (9.5) (10.0) 3/8", 7#8, 3#5, 16M APAS0078 AR2128 AWAR0950 AWAR (10.4) (10.8) 18M AP2130 AR2130 AWAR1040 AWAR (10.8) 0.45 (11.4) 7/16", 7#7, 20M APAS0077 AR2131 AWAR1080 AWAR (12.1) (12.8) 1/2", 7#6 APAS0076 AR2133 AWAR1210 AWAR (13.6) (14.4) 9/16", 7#5 APAS0075 AR2135 AWAR1360 AWAR532

20 Line uards Aluminum Product Data and Conductor Size 18 Conductor Dia. In. (MM) Nominal Conductor Size, (AW or kcmil) Min. Max. ACSR/ACSS ACSR/ACSS TW AAC, AAAC ACAR (7.4) (7.8) #2 PL5130 DPL (7.8) (8.3) #2 6/1 PL5131 DPL (8.3) (8.8) #1 PL5132 DPL (8.8) (9.3) #1 6/1 PL5133 DPL (9.3) (9.9) 1/0 PL5134 DPL (9.9) (10.5) 1/0 6/ PL5135 DPL (10.5) (11.1) 2/0 PL5136 DPL (11.1) (11.8) 2/0 6/1 PL5137 DPL (11.8) (12.4) 3/0 PL5138 DPL (12.5) (13.2) 3/0 6/ PL5139 DPL (13.3) (14.0) 4/0 PL5140 DPL (14.0) (14.9) 4/0 6/1 250 PL5141 DPL (14.9) (15.4) T PL5142 DPL (15.4) (16.0) /1 PL5143 DPL (16.0) (16.6) / PL5144 DPL (16.7) (17.2) T PL5145 DPL (17.3) (17.9) / T23 PL5146 DPL (17.9) (18.8) / T PL5147 DPL (18.8) (20.1) /1 26/7 477 T13 T PL5148 DPL5148 HPS PLP DULMISON HELICAL M0130 M0313 M0131 M0314 M0132 M0315 M0133 M0316 M0134 M0317 M0135 M0318 M0136 M0319 M0137 M0320 M0138 M0321 M0139 M0322 M0140 M0323 M0141 M0324 M0142 M0325 M0143 M0326 M0144 M0327 M0145 M0328 M0146 M0329 M0147 M0330 M0148 M0331 AL0735 DAL0735 AL0785 DAL0785 AL0830 DAL0830 AL0880 DAL0880 AL0930 DAL0930 AL0990 DAL0990 AL1050 DAL1050 AL1110 DAL1110 AL1180 DAL1180 AL1245 DAL1245 AL1325 DAL1325 AL1400 DAL1400 AL1490 DAL1490 AL1540 DAL1540 AL1605 DAL1605 AL1665 DAL1665 AL1725 DAL1725 AL1790 DAL1790 AL1880 DAL1880 AL517 AL617 AL518 AL618 AL519 AL619 AL520 AL620 AL521 AL621 AL522 AL622 AL523 AL623 AL524 A;624 AL525 AL615 AL526 AL626 AL527 AL627 AL528 AL628 AL529 AL629 AL530 AL630 AL531 AL631 AL532 AL632 AL533 AL633 AL534 AL634 AL535 AL635

21 Line uards Aluminum Product Data and Conductor Size (continued) Conductor Dia. In. (MM) Nominal Conductor Size, (AW or kcmil) Min. Max. ACSR/ACSS ACSR/ACSS TW AAC, AAAC ACAR (20.1) (21.3) /7, /1 477 T23, T PL5149 DPL (21.4) (22.8) /7 30/ T16, T T13, 636 T , PL5150 DPL (22.8) (24.2) /7 30/ /1 636 T16, T PL5151 DPL (24.3) (25.0) /7, / T13, 795 T PL5152 DPL (25.1) (25.8) /19, / /7 26/ T16, 795 T PL5153 DPL (25.8) (27) / /7, /7 954 T PL5154 DPL (27.1) (27.9) / /7 954 T , 900 PL5155 DPL (27.9) (29.3) /7 30/ T T7 T T PL5156 DPL (29.3) (30.7) /7 54/ T T13, T PL5157 DPL (30.7) (32.2) / /7 54/ / (32.2) (33.7) / / (33.7) (35.3) / /7 54/ / T13, T T7 T T7 1113, PL5158 DPL T T PL5159 DPL & T & 1590 T , PL5160 DPL (35.3) (36.6) / / & 1622 T PL5161 DPL (36.6) (38.3) / / T T PL5162 DPL5162 HPS PLP DULMISON HELICAL M0149 M0332 M0150 M0333 M0151 M0334 M0152 M0335 M0153 M0336 M0154 M0337 M0155 M0338 M0156 M0339 M0157 M0340 M0158 M0341 M0159 M0342 M0160 M0343 M0161 M0344 M0162 M0345 AL2015 DAL2015 AL2135 DAL2135 AL2285 DAL2285 AL2425 DAL2425 AL2505 DAL2505 AL2585 DAL2585 AL2705 DAL2705 AL2790 DAL2790 AL2930 DAL2930 AL3070 DAL3070 AL3225 DAL3225 AL3375 DAL3375 AL3535 DAL3535 AL3660 DAL3660 AL536 AL636 AL537 AL637 AL538 AL638 AL539 AL639 AL540 AL640 AL541 AL641 AL542 AL642 AL543 AL643 AL544 AL644 AL545 AL645 AL546 AL646 AL547 AL647 AL548 AL648 AL549 AL649 19

22 Protector Rods Aluminum Conductor Dia. In. (MM) Product Data and Conductor Size Nominal Conductor Size, (AW or kcmil) Min. Max. ACSS ACSS TW (12.1) (13.5) PR5139 PR (13.6) (14.9) PR5141 PR (14.9) (15.7) PR5142 PR (15.7) (16.9) /7 PR5144 PR (17.0) (18.3) / T23 PR5146 PR (18.4) (20.7) /7 477 T13, T16 PR5148 PR (20.8) (22.8) /7, 26/7 477 T23 PR5150 PR (22.8) (24.2) /7, 26/7 636 T16, T23 PR5151 PR (24.3) (25.9) /7, 26/ /7, 26/7 765 T13, T16 PR5152 PR (25.9) (27.0) /7, 26/ /7 795 T23 PR5154 PR (27.1) (27.9) /7, 54/7 954 T13 PR5155 PR0155 HPS PLP (27.9) (30.0) /7, 30/ / (30.0) (33.0) /7, / /7, 54/ (33.0) (35.9) /7, 54/ /7, 54/19, / T T13 PR5156 PR T13, T7, T T13, 1272 T7, T13, T7 PR5158 PR T13, T T7, T13 PR5160 PR (36.0) (39.2) / / T13, 1780 T8 PR5162 PR (39.2) (42.8) / / T13, 2156 T8 PR5163 PR (42.8) (46.7) / / T8 PR5164 PR0164

Armor Rods. Armor Rods NOMENCLATURE GENERAL RECOMMENDATIONS

Armor Rods. Armor Rods NOMENCLATURE GENERAL RECOMMENDATIONS Transmission: Section 1 NOMENCLATURE Single Support and Double Support : Identified by S and D appearing in the length column on the catalog page. Should the maximum distance between tied supports exceed

More information

SPIRAL VIBRATION DAMPERS FOR AAC, AAAC, ACSR, COPPER, SC/AC & SC/GZ CONDUCTORS. Part Number

SPIRAL VIBRATION DAMPERS FOR AAC, AAAC, ACSR, COPPER, SC/AC & SC/GZ CONDUCTORS. Part Number SPIRAL VIBRATION DAMPERS FOR AAC, AAAC, ACSR, COPPER, SC/AC & SC/GZ CONDUCTORS Made from high impact, UV resistant, polyvinyl chloride (PVC), they are non-corrosive and do not abrade the conductor or require

More information

GSA Series Formed Wire Suspension

GSA Series Formed Wire Suspension GSA Series Formed Wire Suspension Formed Wire Suspension Unit AFL is a renowned manufacturer of aluminum conductor accessories, manufacturing numerous products for the electric utility industry since the

More information

Section 4 - Protection

Section 4 - Protection Transmission Catalogue : Section 4 Protection Section 4 - Protection Table of Contents Section/Page PREFORMED Armor Rods For AAC, AAAC and ACSR s... 4-3 For AAC, AAAC and ACSR s (Subset)... 4-3 For SC/GZ

More information

VORTX Vibration Damper

VORTX Vibration Damper Product Identification 1 2 3 5 4 NOMENLTURE 1. lamp & Keeper: The lamp has an extruded hook shaped profile to hang onto the cable or conductor while tightening the keeper. Together, the aluminum keeper

More information

THERMOLIGN Products for 3M Aluminum Conductor Composite Reinforced (3M ACCR)

THERMOLIGN Products for 3M Aluminum Conductor Composite Reinforced (3M ACCR) Products for 3M Aluminum Conductor Composite Reinforced (3M ACCR) July 2015 History of Hardware at PLP Preformed Line Products has been involved with the design, testing and production of hardware and

More information

VORTXô VIBRATION DAMPER

VORTXô VIBRATION DAMPER VORTXô VIRTION DMPER ontoured lamp Technical Support - when you need it! PLP Motion ontrol Products VORTXô Vibration Damper From the Recognized Leader in onductor Protection Much of PLP s business has

More information

ARMOR-GRIP Suspension: Double

ARMOR-GRIP Suspension: Double : Double For Line Angles Between 30 and 60 ACSR, All-Aluminum, Aluminum Alloy, AWAC Compacted All-Aluminum Compacted ACSR, ACSS, ACSS/TW Range AGS s AGS AGS s & Min. Max. Nominal Conductor Size s Per Set

More information

Slack Span Dead-end GENERAL RECOMMENDATIONS NOMENCLATURE (440)

Slack Span Dead-end GENERAL RECOMMENDATIONS NOMENCLATURE (440) NOMENCLATURE Material Helical Leg Section: Aluminum covered steel. An aluminum alloy version is available for corrosive environment. Contact PLP. Crossover Marks: Indicates starting point for application

More information

TRANSMISSION LINE REPAIR MANUAL. A guidebook for the inspection and repair of damaged or worn conductors

TRANSMISSION LINE REPAIR MANUAL. A guidebook for the inspection and repair of damaged or worn conductors TRANSMISSION LINE REPAIR MANUAL A guidebook for the inspection and repair of damaged or worn conductors August 2017 PREFACE Since 1947 Preformed Line Products has been a recognized leader in the business

More information

Jumper Terminals and Tee Taps. delivery

Jumper Terminals and Tee Taps. delivery Jumper Terminals and Tee Taps delivery November 017 November 017 Jumper Terminals & Tee Taps Index Compression/Aluminum JTS... Straight Pad for AAC, AAAC, ACAR & ACSR Conductor... -1 JTF... 15 Degree Pad

More information

SUSPENSION 04 CLAMPS

SUSPENSION 04 CLAMPS SUSPENSION CLAMPS 04 4 SUSPENSION CLAMPS 57 Contents General... 58 Suspension clamp trunnion type, forged,... 63 Suspension clamp trunnion type, forged, with bigger angle of deflection, for aluminium based

More information

Power System Analysis I TRANSMISSION LINE PARAMETERS

Power System Analysis I TRANSMISSION LINE PARAMETERS Power System Analysis I TRANSMISSION LINE PARAMETERS Components of Overhead Lines Transmission Line Parameters An overhead transmission line consists of conductors, insulators, support structures, and,

More information

MATERIAL FOR FIBRE OPTIC LINES. General C-bracket HSU trunnion type, forged, for aluminium based OPGW conductors...

MATERIAL FOR FIBRE OPTIC LINES. General C-bracket HSU trunnion type, forged, for aluminium based OPGW conductors... 153 Contents General.................................................................................................. 154 C-bracket.................................................................................................

More information

SPACERS AND SPACER DAMPERS

SPACERS AND SPACER DAMPERS SPACERS AND SPACER DAMPERS 0 131 Contents General... 132 Spacer damper aluminium, for horizontal twin bundles... 138 Spacer damper aluminium, for vertical twin bundles... 138 Spacer damper aluminium, for

More information

FIBERLIGN Suspension for OPGW

FIBERLIGN Suspension for OPGW IERLIN Suspension for OPW NOMENCLTURE 1. olt 6. Housing 2. Lock washer 7. Strap 3. Lock nut 8. Structural Reinforcing Rods 4. Outer Rods 9. Current Transfer Tab 5. Insert (for OPW only) iberlign Suspension

More information

August THERMOLIGN Products for CTC ACCC Conductor

August THERMOLIGN Products for CTC ACCC Conductor August 2017 THERMOLIGN Products for CTC ACCC Conductor History of THERMOLIGN Hardware at PLP Preformed Line Products has been involved with the design, testing and production of hardware and accessories

More information

Standard Compression Dead End for ACSR and ACSS Conductor CAUTION: ACSR Dead Ends Cannot Be Used on ACSS HT Conductor

Standard Compression Dead End for ACSR and ACSS Conductor CAUTION: ACSR Dead Ends Cannot Be Used on ACSS HT Conductor INS-ACA089 Installation Instructions Standard Compression Dead End for ACSR and ACSS Conductor CAUTION: ACSR Dead Ends Cannot Be Used on ACSS HT Conductor 1. Mark the conductor a distance of 3 /4 the length

More information

EXCLUSIVE AUSTRALIAN DISTRIBUTORS

EXCLUSIVE AUSTRALIAN DISTRIBUTORS Helical Fittings EXCLUSIVE AUSTRALIAN DISTRIBUTORS B4/1 Introduction in helical fittings Helical fittings are composed of single helical rods which -according to the respective application - are separate

More information

DISTRIBUTION catalogue

DISTRIBUTION catalogue hardware & accessories jointing DISTRIBUTION catalogue Australian Manufactured Overhead Fittings for Power Distribution termination DISTRIBUTION catalogue protection Also available: Transmission Catalogue

More information

Section 5 Fiber Optics: FIBERLIGN Hardware for OPGW

Section 5 Fiber Optics: FIBERLIGN Hardware for OPGW FIBERLIGN Hardware for OPGW: Section Section Fiber Optics: FIBERLIGN Hardware for OPGW Table of Contents Page Fiber Optic Product Layout for OPGW...-2 FIBERLIGN ead-end for OPGW...-3 FIBERLIGN Formed Wire

More information

Company Profile. ZTT Cable was established in 1992, and now becomes a public high-tech enterprise with 33 subsidiaries, and about 7,000 employees.

Company Profile. ZTT Cable was established in 1992, and now becomes a public high-tech enterprise with 33 subsidiaries, and about 7,000 employees. Company Profile ZTT Cable was established in 1992, and now becomes a public high-tech enterprise with 33 subsidiaries, and about 7,000 employees. We provide products such as electrical fittings, optical

More information

Section 6 FIBERLIGN Hardware for ADSS

Section 6 FIBERLIGN Hardware for ADSS FIBERLIGN Hardware for ADSS: Section 6 Section 6 FIBERLIGN Hardware for ADSS Table of Contents Page Fiber Optic Product Layout for ADSS...6-2 FIBERLIGN Lite Tension Dead-end for ADSS...6-3 FIBERLIGN Dielectric

More information

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-17453-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 03.07.2017 to 02.07.2022 Holder of certificate: SPIE

More information

EARTH WIRE FITTINGS 08

EARTH WIRE FITTINGS 08 EARTH WIRE FITTINGS 08 8 EARTH WIRE FITTINGS 119 Contents General... 120 C-bracket... 123 Suspension clamp with bolt, with straps, for steel and copper conductors... 123 Suspension clamp with bolt, with

More information

Suspension Clamps. performance

Suspension Clamps. performance Suspension Clamps performance Suspension Clamps Index olted/aluminum CFS... Corona Free Clamp for Use With Armor Rods...-3 CFS (ONG)... Corona Free Clamp for Use Without Armor Rods...-4 CFSHT... Corona

More information

POLYMER INSULATOR. Index

POLYMER INSULATOR. Index POLYMER INSULATOR Index INTRODUCTION...2 IEC COMPOSITE INSULATORS...7 ANSI COMPOSITE INSULATORS...14 Introduction General This new generation of Polymer Insulator characterized with: Small Light High mechanical

More information

Aluminum Conductor Composite Reinforced Installation Guidelines and Maintenance

Aluminum Conductor Composite Reinforced Installation Guidelines and Maintenance 3 Aluminum Conductor Composite Reinforced Installation Guidelines and Maintenance 1 Contents Installation Guidelines and Maintenance for ACCR Aluminum Conductor Composite Reinforced 1. Introduction 4 2.

More information

Heat-Shrinkable Tubing

Heat-Shrinkable Tubing H-Tap Insulating Covers (Hard Covers) Interlocking insulating covers for H-type compression taps Easy installation: place the H-Tap in the cover and snap the cover closed Consult your Regional Sales Office

More information

PLP Compression Dead-end & Jumper Terminal for ACSR & ACSS Conductors

PLP Compression Dead-end & Jumper Terminal for ACSR & ACSS Conductors MARCH 2017 PLP Compression Dead-end & Jumper Terminal for ACSR & ACSS Conductors Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED

More information

APS 113 ELECTRO-SEIS Long Stroke Shaker with Linear Ball Bearings Page 1 of 5

APS 113 ELECTRO-SEIS Long Stroke Shaker with Linear Ball Bearings Page 1 of 5 Long Stroke Shaker with Linear Ball Bearings Page 1 of 5 The ELECTRO-SEIS shaker is a long stroke, electrodynamic force generator specifically designed to be used alone or in arrays for studying dynamic

More information

Wire Management Products Index

Wire Management Products Index Section T Wire Management Products Index Product Page Number Kellems Wire Mesh Grips T-2 3 Pulling Grips T-4 16 DUA-PULL Grips T-6 DUA-PULL Feed Tube T-6 Overhead Multiple Strength T-7 Underground Pulling

More information

The reinforcing rods are incorporated in this assembly to ensure the optical fibres within the OPGW Range

The reinforcing rods are incorporated in this assembly to ensure the optical fibres within the OPGW Range OPGW Suspension Assemblies Optical Fibre Cable Same lay as OPGW outer stranding H Reinforcing rods opposite lay to OPGW outer stranding S L Application Heliformed suspension assemblies designed for use

More information

APS 420 ELECTRO-SEIS Long Stroke Shaker with Linear Ball Bearings Page 1 of 5

APS 420 ELECTRO-SEIS Long Stroke Shaker with Linear Ball Bearings Page 1 of 5 Long Stroke Shaker with Linear Ball Bearings Page 1 of 5 The APS 420 ELECTRO-SEIS shaker is a long stroke, electrodynamic force generator specifically designed to be used alone or in arrays for studying

More information

Installation Instructions. Y-Series Brushless Servo Motor

Installation Instructions. Y-Series Brushless Servo Motor Installation Instructions Y-Series Brushless Servo Motor Catalog Number Y-1002-1, Y-1002-2, Y-1003-1, Y-1003-2, Y-2006-1, Y-2006-2, Y-2012-1, Y-2012-2, and Y-3023-2 These installation instructions describe

More information

PROTECTIVE FITTINGS I N D E X

PROTECTIVE FITTINGS I N D E X I N D E X PROTECTIVE FITTINGS Vibration Dampers Type 4D. Page B-2 & B-3 Twin Spacer-dampers Type SD2.. Page B-5 Triple Spacer-dampers Type SD3.. Page B-6 Quad Spacer-dampers Type SD4.. Page B-7 Six bundle

More information

Aeolian Vibration Basics

Aeolian Vibration Basics Aeolian Vibration Basics October 2013 Part of a series of reference reports prepared by Preformed Line Products Contents Aeolian Vibration Basics Page Abstract...1 Mechanism of Aeolian Vibrations...1

More information

Compression Hardware Series For ACSR Conductors

Compression Hardware Series For ACSR Conductors Compression Hardware Series For ACSR Conductors PAGE 4 5 6 7 CONTENTS Compression Dead-end - CMPDE Compression Jumper Terminal - CMPTM Compression Dead-end assembly - cmpdej compression splice assembly

More information

SPEC No.: ZP REVISION: 1.1 ZP ELECTRON CO.,INC. Designer. Division. Approver

SPEC No.: ZP REVISION: 1.1 ZP ELECTRON CO.,INC. Designer. Division. Approver TECHNICAL SPECIFICATION FOR Optical Fiber Overhead Ground Wire (OPGW) Designer Approver SPEC No.: ZP10-15389 REVISION: 1.1 Technical Supporter ZP Int ternational Division Chief Technical Engineer ZP Int

More information

APS 400 ELECTRO-SEIS. Long Stroke Shaker Page 1 of 5. Applications. Features

APS 400 ELECTRO-SEIS. Long Stroke Shaker Page 1 of 5. Applications. Features Long Stroke Shaker Page 1 of 5 The APS 400 ELECTRO-SEIS is a force generator specifically designed to be used alone or in arrays for studying dynamic response characteristics of various structures. It

More information

TENSION CLAMPS AND JOINTS. General Wedge tension clamp without jumper guide, for aluminium based conductors... 79

TENSION CLAMPS AND JOINTS. General Wedge tension clamp without jumper guide, for aluminium based conductors... 79 73 Contents General.................................................................................................. 74 Wedge tension clamp without jumper guide, for aluminium based conductors...........................

More information

OPGW and ADSS Fiber Cable. For Overhead Transmission Lines

OPGW and ADSS Fiber Cable. For Overhead Transmission Lines OPGW and ADSS Fiber Cable For Overhead Transmission Lines PRYSMIAN GROUP VISION, MISSION, VALUES Vision The Prysmian Group believes in the effective, efficient and sustainable supply of Energy and Information

More information

Australian Manufactured Fittings & Accessories for Communication Networks. Also available:

Australian Manufactured Fittings & Accessories for Communication Networks. Also available: Australian Manufactured Fittings & Accessories for Communication Networks Also available: Transmission Catalogue Substation Catalogue Distribution Catalogue Preformed Line Products Preformed Line Products

More information

Overhead transmission lines Vibrationdampers

Overhead transmission lines Vibrationdampers SVENSKA KRAFTNÄT SWEDISH NATIONAL GRID UNIT, BUSINESS AREA AFL, Asset Management Lines OUR REFERENCE TR05-09-1E DATE 2016-06-09 CONSULTATIONS TECHNICAL GUIDELINE REVISION 3 Td APPROVED Overhead transmission

More information

Aluminum and Steel Liquidtight Strain Relief Cord and Cable Connectors

Aluminum and Steel Liquidtight Strain Relief Cord and Cable Connectors Application Provide a liquidtight and strain relief termination for flexible type neoprene, hypalon, and PVC jacketed power or control cord and cable. For use in wet or dry locations sealing electrical

More information

Heat-Shrinkable Tubing

Heat-Shrinkable Tubing H-Tap Insulating Covers (Hard Covers) Interlocking insulating covers for H-type compression taps Easy installation: place the H-Tap in the cover and snap the cover closed Consult your Regional Sales Office

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-Hazardous Areas

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-Hazardous Areas 1P Arktite Heavy Duty Circuit Breaking s and s Industrial Heavy Duty Non-Hazardous Areas Application: Arktite circuit breaking plugs and receptacles are used: to supply power to portable electrically operated

More information

TUBULAR CENTRIFUGAL INLINE FANS

TUBULAR CENTRIFUGAL INLINE FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS TUBULAR CENTRIFUGAL INLINE FANS MODEL TSL CATALOG 1001 APRIL 2014 CENTRIFUGAL INLINE FANS Model TSL The TSL is an inline centrifugal

More information

TRANSMISSION PRODUCTS

TRANSMISSION PRODUCTS TRANSMISSION PRODUCTS INDEX Deadends bolted/aluminum AR1/AR2... QUADRANT STRAIN CLAMP...TA-4 PG/DE... QUADRANT STRAIN CLAMP...TA-3 SD... QUADRANT STRAIN CLAMP...TA-1 SDT2... DOUBLE GROOVE STRAIN CLAMP...TA-2

More information

SHAFT MOUNT REDUCERS. For Additional Models of Shaft Mount Reducers See Sections F & J G-1

SHAFT MOUNT REDUCERS. For Additional Models of Shaft Mount Reducers See Sections F & J G-1 SHAFT MOUNT REDUCERS PowerTorque Features and Description... -2 Nomenclature... -4 Selection Instructions... -5 Selection By Horsepower... -7 Mechanical Ratings... -12 Dimensions... -14 Accessories...

More information

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles 1P Arktite Heavy Duty Circuit Breaking s and Receptacles Industrial Heavy Duty Non-Hazardous Areas Application: Arktite circuit breaking plugs and receptacles are used: to supply power to portable electrically

More information

Manufacturing quality. Delivering service. Single Conductors DESCRIPTION: Single copper conductor, tinned stranded insulated with moisture and heat resistant, chemically cross-linked polyethylene insulation

More information

Wildlife Protection Products

Wildlife Protection Products Wildlife Protection Products Jerry Liguori Jerry Liguori Wildlife Protection and Deterrent Hardware Solutions 2 1 7 8 9 4 6 3 5 6 7 3 8 8 10 6 6 5 9 Solutions Key Protect Divert 1. RAPTOR PROTECTOR 2.

More information

Wildlife Protection Products. Jerry Liguori

Wildlife Protection Products. Jerry Liguori Wildlife Protection Products Jerry Liguori Wildlife Protection and Deterrent Hardware Solutions 2 1 8 9 10 5 7 4 3a. 6 7 8 4 9 9 3b. 11 7 7 6 10 Solutions Key Protect 5. Protector Tubing 1. RAPTOR PROTECTOR

More information

SUSPENSION 04 CLAMPS

SUSPENSION 04 CLAMPS SUSPENSION CLAMPS 04 4 SUSPENSION CLAMPS 57 Contents General... 58 Suspension clamp trunnion type, forged, for aluminium based conductors... 63 Suspension clamp trunnion type, forged, with bigger angle

More information

VDBA INDOOR SINGLE & TWIN LINE DUCT BLOWERS

VDBA INDOOR SINGLE & TWIN LINE DUCT BLOWERS VDBA INDOOR SINGLE & TWIN LINE DUCT BLOWERS VDBA INDOOR SINGLE & TWIN LINE DUCT BLOWERS SECTION 11 OPTIONAL ACCESSORIES VXDAF filter sections are insulated and supplied with 1 framed aluminum mesh filter.

More information

VALMONT MITIGATOR TR1

VALMONT MITIGATOR TR1 VALMONT MITIGATOR TR1 Research Verification of the Valmont TR1 Damper Performance MITIGATOR TR1 VIBRATION DAMPER The Valmont TR1 damper has been specifically designed using vibration theory and innovative

More information

Ground Wire Size. 1/2 in /4 in. 2 in /2 in. 3-1/2 in TB. 4 in. 5 in. #4 4/0 AWG 3906-TB

Ground Wire Size. 1/2 in /4 in. 2 in /2 in. 3-1/2 in TB. 4 in. 5 in. #4 4/0 AWG 3906-TB lamps Waterpipe Ground lamps Waterpipe Ground lamps Waterpipe Ground lamps 2-T Ground Wire Size Water Pipe Size 1/2 in., 3/4 in., 1 or rebar 4-10 3-T 1-1/4 in., 1-1/2 in. or 2 in. #6, #4, #2 WG 4 2-1/2

More information

Instructions. Quick Term II 2047MT 56. 3M Quick Term II. Silicone Rubber Termination (with High-K Stress Relief)

Instructions. Quick Term II 2047MT 56. 3M Quick Term II. Silicone Rubber Termination (with High-K Stress Relief) Instructions Quick Term II Silicone Rubber Termination (with High-K Stress Relief) IEEE Std. No. 48 990 Class Termination 5 kv Class 50 kv BIL Kit Contents Hi K Silicone Rubber Termination Scotch 70 Silicone

More information

Frequently Asked Questions

Frequently Asked Questions Frequently Asked Questions 1) Please explain the electrical performance of ClampStar Tel. 800-269-1462 Fax. 800-311-9857 382 Park Ave East, Mansfield, OH 44905 www.classicconnectors.com Classic Connectors

More information

SECTION 3 - PRIMARY CONSTRUCTION OVERHEAD TABLE OF CONTENTS

SECTION 3 - PRIMARY CONSTRUCTION OVERHEAD TABLE OF CONTENTS 03.00 GENERAL CONSTRUCTION NOTES PRIMARY CONSTRUCTION PRIMARY CONSTRUCTION PIN INSULATOR INSTALLATION 03.00-02 03.00-04 03.00-20 03.02 CONNECTORS AUTOMATIC SPLICE INSTALLATION 03.02-01 INSTALLATION GUIDE

More information

Quick Term II. Cold Shrink Silicone Rubber Termination. Quick Term II. Instruction Sheet

Quick Term II. Cold Shrink Silicone Rubber Termination. Quick Term II. Instruction Sheet Quick Term II Cold Shrink Silicone Rubber Termination Instruction Sheet IEEE Std. No. 48 1990 Class 1 Termination 15 kv Class 110 kv BIL Kit Contents: 1 Hi K Silicone Rubber Termination 2 Scotch 70 Silicone

More information

Wire Mesh Safety Grips

Wire Mesh Safety Grips Pulling Grips PS Series S PS Series grips feature a double weave of galvanized steel strands for greater strength and added mesh contact with the cable. Leviton Double Weave Pulling Grips are designed

More information

TECHNICAL SPECIFICATION FOR SHACKLE HARDWARE FITTINGS SUITABLE FOR TENSION STRING TO BE USED FOR 11KV LINE

TECHNICAL SPECIFICATION FOR SHACKLE HARDWARE FITTINGS SUITABLE FOR TENSION STRING TO BE USED FOR 11KV LINE TECHNICAL SPECIFICATION FOR SHACKLE HARDWARE FITTINGS SUITABLE FOR TENSION STRING TO BE USED FOR 11KV LINE The hardware fittings suitable for tension string to be used for 11KV consisting of following

More information

Easier! Faster! Safer!

Easier! Faster! Safer! Gexol CIR Crush and Impact Resistant Without External Armoring Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL Index CIR Power Cables Three & Four Conductor + Ground...

More information

/ CABLE TIES & WIRE FASTENERS /

/ CABLE TIES & WIRE FASTENERS / Standard Self-locking Cable Ties information INFO Melting point: 265 C (509 F) Brittleness temperature: -112 C (-169 F) at 2% water Provide up to 50% more tensile strength and 15% larger bundle diameters

More information

Impact, Torsion, and Crush Tests for 477 kcmil and 795 kcmil 3M Brand Composite Conductor. 3M Company Purchase Order

Impact, Torsion, and Crush Tests for 477 kcmil and 795 kcmil 3M Brand Composite Conductor. 3M Company Purchase Order Impact, Torsion, and Crush Tests for 477 kcmil and 795 kcmil 3M Brand Composite Conductor 3M Company Purchase Order 0000620410 NEETRAC Project Number: 02-229 October, 2002 A Center of The Georgia Institute

More information

Bolted Dead End for OPGW

Bolted Dead End for OPGW Bolted Dead End for OPGW The AFL Dead End is a full tension termination for Optical Ground Wire cable. Breakaway head bolts are used to apply a precise gripping force to hold the cable without affecting

More information

HVS S 15kV Class

HVS S 15kV Class Product HVS-3-1580S 15kV Class Transition Splice for 3/C to 3/C Extruded Dielectric (Poly/EPR) Power Cables Raychem Corporation Electrical Products 8000 Purfoy Road Fuquay-Varina, NC 27526 PII-54864, Rev

More information

Mixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data

Mixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data Mixed-Flow Blowers Page Introduction.......................................... 2-4 Standard Construction Features.......................... 5-7 Mixed-Flow Advantages.................................. 8

More information

Aluminum Conductor Composite Reinforced Installation Guidelines and Maintenance

Aluminum Conductor Composite Reinforced Installation Guidelines and Maintenance Aluminum Conductor Composite Reinforced Installation Guidelines and Maintenance 1 Contents Installation Guidelines and Maintenance for 3M ACCR Aluminum Conductor Composite Reinforced 1. Introduction.4

More information

Number Tube I.P.S. Rod Size or O.D. Range Cable H J W

Number Tube I.P.S. Rod Size or O.D. Range Cable H J W TYPE GAR D-28 FENCE POST GROUNDING CONNECTOR For Parallel or 90 Copper Cable Connection To Rod or Pipe with the Same Connector High copper alloy ground connector for joining a range of cable, parallel

More information

026-2 : 1996 CEB STANDARD

026-2 : 1996 CEB STANDARD 026-2 : 1996 CEB STANDARD COMPRESSION CONNECTORS & TERMINATIONS FOR OVERHEAD LINE CONDUCTORS CEYLON ELECTRICITY BOARD SRI LANKA CONTENTS 1. Scope 2 2. System Parameters 2 3. Service Conditions 2 4. Applicable

More information

RSK Connectors and Installation Tools

RSK Connectors and Installation Tools Grounding Connectors RSK Connectors and Installation Tools...2-4 Two-Piece Grounding Connectors for Shielded and Coaxial Cable...5-7 Color-Coded Tool and Die Selection System...8-9 Connector for Multiple

More information

FILTERED AIR SUPPLY FANS

FILTERED AIR SUPPLY FANS BULLETIN 664-B September 2004 FILTERED AIR SUPPLY FANS Wall Mounted Roof Mounted Catalog Numbering System To identify a specific fan for ordering or engineering specification, it is necessary to show

More information

TECHNICAL SPECIFICATIONS FOR HARDWARE & ACCESSORIES -ACSR DOG CONDUCTOR FOR TRANSMISSION LINE

TECHNICAL SPECIFICATIONS FOR HARDWARE & ACCESSORIES -ACSR DOG CONDUCTOR FOR TRANSMISSION LINE GUJARAT ENERGY TRANSMISSION CORPORATION LTD. Sardar Patel Vidyut Bhavan, Race Course, Vadodara: 390 007 TECHNICAL SPECIFICATIONS FOR HARDWARE & ACCESSORIES -ACSR DOG CONDUCTOR FOR TRANSMISSION LINE GETCO/E/TS

More information

Polymer Insulators A Better Solution

Polymer Insulators A Better Solution Polymer Insulators A Better Solution October 2016 LET S CONNECT POLYMER INSULATORS Design derived from PLP s many years of worldwide experience and tested to adhere to ANSI C29.5 and ANSI 29.6 insulator

More information

Instructions. Quick Term II 2047MT 74. Quick Term II. Silicone Rubber Termination

Instructions. Quick Term II 2047MT 74. Quick Term II. Silicone Rubber Termination Instructions Quick Term II Silicone Rubber Termination IEEE Std. No. 48 1990 Class 1 Termination 46 kv Class 250 kv BIL ÁÁ ÁÁ Kit Contents 1 High-K, 8 Skirted Silicone Rubber Termination 1 4 Skirt Silicone

More information

Cam-Lok Single Pole Connectors

Cam-Lok Single Pole Connectors Cam-Lok Single Pole Connectors Cooper Interconnect Cam-Lok Single Pole Connectors are specially designed to provide the ultimate in reliable service, even under the most severe operating conditions. These

More information

3M Cold Shrink QT-II Silicone Rubber Indoor Termination Kits

3M Cold Shrink QT-II Silicone Rubber Indoor Termination Kits 3M Cold Shrink QT-II Silicone Rubber Indoor Termination Kits With High-K Stress Relief For Tape Shield, Wire Shield and UniShield Instructions IEEE Std. No. 48 Class 1 Termination 8 kv Class, 95 kv BIL:

More information

CABLE GRIPS Strain-Relief Grips Pulling Grips Support Grips

CABLE GRIPS Strain-Relief Grips Pulling Grips Support Grips Tough and dependable, Woodhead cable grips and cord grip bodies are reliable workhorses in any plant environment. They serve as flexible holding devices used to pull cable, rope, or tubing into place,

More information

Wildlife Protection Products

Wildlife Protection Products Wildlife Protection Products Jerry Liguori Jerry Liguori Wildlife Protection and Deterrent Hardware Solutions 2 1 8 9 10 3b. 5 7 4 3a. 6 7 8 4 9 9 3b. 11 7 7 6 10 Solutions Key Protect 5. Protector Tubing

More information

Cold Shrink Silicone Rubber Termination QT-III (With High-K Stress Relief)

Cold Shrink Silicone Rubber Termination QT-III (With High-K Stress Relief) Cold Shrink Silicone Rubber Termination QT-III (With High-K Stress Relief) Instruction Sheet IEEE Std. No. 48 1990 Class 1 Termination 5/8.7 kv Class 95 kv BIL Kit Contents: 3 Hi K, Tracking Resistant,

More information

Annexure B (1)- Engineering Instructions for Installation of Aerial OFC

Annexure B (1)- Engineering Instructions for Installation of Aerial OFC Annexure B (1)- Engineering Instructions for Installation of Aerial OFC INSTALLATION PRACTICE OF SELF SUPPORTING METAL FREE AERIAL OPTICAL FIBER CABLE 1. SCOPE: This Engineering Instruction (EI) deals

More information

Section 5 FIBERLIGN Hardware for OPGW

Section 5 FIBERLIGN Hardware for OPGW FIBERLIGN Hardware for OPGW: Section Section FIBERLIGN Hardware for OPGW Table of Contents Page Fiber Optic Product Layout for OPGW...-2 FIBERLIGN Dead-end for OPGW...-3 FIBERLIGN Formed Wire Dead-end...-6

More information

HANGERS, STRUT, AND FITTINGS SUBMITTAL

HANGERS, STRUT, AND FITTINGS SUBMITTAL HANGERS, STRUT, AND FITTINGS SUBMITTAL Prepared By: Submitted by: Enter Company Name INTERNATIONAL SEISMIC APPLICATION TECHNOLOGY A Division of Tomarco Contractor Specialties Enter Project Name 4848 Northam

More information

S&C Circuit-Switcher Mark VI Outdoor Transmission (69 kv through 138 kv)

S&C Circuit-Switcher Mark VI Outdoor Transmission (69 kv through 138 kv) Outdoor Transmission (69 kv through 138 kv) Construction Guide This publication sets forth the data required for the user to design a support structure or pedestals for a Mark VI Circuit-Switcher; the

More information

VITALink Taped Splice Pigtail Crimp

VITALink Taped Splice Pigtail Crimp A Marmon Wire & Cable Berkshire Hathaway Company VITALink Taped Splice Pigtail Crimp 1 Hour Fire-Rated Splice VITALink MC Cables, UL FHIT 120 Installation Instructions Description The VITALink Taped Splice

More information

BESTEEL Model 170 Curtain Tracks BESTEEL Model 171-N Curtain Tracks BESTEEL Model 171-R Curtain Tracks

BESTEEL Model 170 Curtain Tracks BESTEEL Model 171-N Curtain Tracks BESTEEL Model 171-R Curtain Tracks BESTEEL Model 170 Curtain Tracks - Curtain tracks shall be of 14 gauge galvanized steel construction entirely enclosed except for slot in bottom, each half to be in one continuous piece except where splicing

More information

University of Delaware

University of Delaware SECTION 23 36 00 _ SUMMARY PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Constant/Variable volume supply terminal units. 2. Fan powered terminal units. 3. Exhaust valves B. Related Sections: Section

More information

OPTOFIT CATALOGUE. FITTINGS FOR METALFREE (ADSS CABLES) and METAL ARMOURED (OPGW & OPPW) AERIAL CABLES WITH INTEGRATED OPTICAL FIBRES.

OPTOFIT CATALOGUE. FITTINGS FOR METALFREE (ADSS CABLES) and METAL ARMOURED (OPGW & OPPW) AERIAL CABLES WITH INTEGRATED OPTICAL FIBRES. OPTOFIT CATALOGUE FITTINGS FOR METALFREE (ADSS CABLES) and METAL ARMOURED (OPGW & OPPW) AERIAL CABLES WITH INTEGRATED OPTICAL FIBRES. EXCLUSIVE AUSTRALIAN DISTRIBUTORS B8/8 Introduction Metalfree (ADSS

More information

4. SHIELDS. 4.1 Power Cable. 4.2 Electronic Cable Conductor Shield (Strand Shield) Outer Shield (Insulation Shield) 60

4. SHIELDS. 4.1 Power Cable. 4.2 Electronic Cable Conductor Shield (Strand Shield) Outer Shield (Insulation Shield) 60 4. SHIELDS 4.1 Power Cable 4.1.1 Conductor Shield (Strand Shield) 60 4.1.2 Outer Shield (Insulation Shield) 60 4.2 Electronic Cable 4.2.1 Foil Shield 62 4.2.2 Copper Braid Shield 63 4.2.3 Spiral (Serve)

More information

B Polyethylene Tape. B Splicing Covering. Holster

B Polyethylene Tape. B Splicing Covering. Holster Splicing Materials B Polyethylene Tape Translucent 8-mil polyethylene tape made from electrical grade base material. Intended for use in restoring the dielectric strength between the core and sheath at

More information

3M Cold Shrink QT-III Silicone Rubber Indoor Tubular Termination Kit

3M Cold Shrink QT-III Silicone Rubber Indoor Tubular Termination Kit 3M Cold Shrink QT-III Silicone Rubber Indoor Tubular Termination Kit With High-K Stress Relief For Tape Shield, Wire Shield and UniShield Cable 7622-T-110, 7624-T-110, 7625-T-110, 7626-T-110 Instructions

More information

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile Centrifugal Cabinet s BCF Belt Drive Low-Profile November 204 BCF Centrifugal Cabinet Contents Standard Construction Features... 3 Options and Accessories... 4 Filter and Mixing Box Data... 5 Typical Installations...

More information

SECTION AXIAL HVAC FANS

SECTION AXIAL HVAC FANS SECTION 233413 - AXIAL HVAC FANS 1. PART 1 GENERAL 1.1. RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AP20467S22 3W-4P 200A Plug Cooper Crouse-Hinds Catalog Number AP20467S22 Manufacturer Cooper Crouse-Hinds Description

More information

Substation Design Volume III

Substation Design Volume III PDHonline Course E470 (3 PDH) Substation Design Volume III Conductors & Bus Design Instructor: Lee Layton, P.E 2015 PDH Online PDH Center 5272 Meadow Estates Drive Fairfax, VA 22030-6658 Phone & Fax: 703-988-0088

More information

Dodge Torque-Arm II The Legacy Continues

Dodge Torque-Arm II The Legacy Continues Torque-Arm II Dodge Torque-Arm II The Legacy Continues The Dodge Torque-Arm II surpasses all other reducers on the market because of its industry proven design and patented features. This powerful line

More information

00000 Series Clevis Pin Slotted Hexagon Hex Key Recommended Corresponding Part No. Part No. Size Torque Preload SLT* SLT* HEX

00000 Series Clevis Pin Slotted Hexagon Hex Key Recommended Corresponding Part No. Part No. Size Torque Preload SLT* SLT* HEX 00000 Series Clevis Pin All clevis pins are manufactured from heat treated 416 stainless steel to provide superior strength and wear. Hardness is between 37-40 Rc. The DCD Clevis Pin is a shouldered type

More information