1 MEETING AGENDA Western Area Power Administration Rocky Mountain Region Transmission Planning Stakeholder Meeting Western s RMR Regional Office 5555 East Crossroads Boulevard, Loveland, CO June 23, :30 pm to 3:30 pm MDT 1) 1:30 pm... Introduction of Attendees \ Finalize Agenda (Bob Easton) 2) 1:35 pm... Overview of the Western s Process for FERC Order No. 890 (Debbie Farm) 3) 1:45 pm... West Connect Transmission Update (Bob Easton) 4) 2:00 pm... Transmission Planning Studies (Jim Hirning) 5) 2.15 pm... Review of 2014 Transmission Planning Study Scope & Process (Jason Parker) 6) 2:30 pm... Big Horn Basin Area Study Results (Susan Franklin) 7) 2:45 pm... Capital Investment Plan (Susan Franklin) 8) 3:15 pm... Stakeholder Input / Open Discussion (Bob Easton) 9) 3:25 pm... Next Meeting Date (December 11, 2014) and Closing Remarks (Bob Easton) 10) 3:30 pm... Adjourn

2 Western Area Power Rocky Mountain Region Planning Stakeholder Meeting (Western OATT Attachment P) June 23, 2014

3 Meeting Purpose To inform stakeholders about Western s transmission system planning process and an opportunity for the stakeholders to provide their input Allow Western to maximize its understanding of its customers forecasted needs for Western s transmission system Review transmission plans

4 OATT Revision Order 890 issued Feb. 16, 2007 Western maintains a safe harbor OATT with FERC Not required to abide by Order 890 compliance deadlines like jurisdictional TPs Resources and projects are based on statutory or budgetary restrictions Any variances in the FERC approved OATT must be justified to customers and accepted by FERC May make modifications that are consistent with or superior to pro forma OATT provisions Western revised OATT to address Order 890 Submitted to FERC September 29, 2009 Effective Date: December 1,

5 OATT Revision Western has filed revisions to its OATT to clarify certain provisions. FERC approved April 12, 2013 OATT Revisions can be viewed through FERC s tariff viewer: Tariff documents are posted on OASIS at the following URL: Effective pdf 4

6 FERC Order 890 Planning Principles Transmission Planning: FERC requires a more inclusive transmission planning process incorporating nine principles: (1) coordination, (2) openness, (3) transparency, (4) information exchange, (5) comparability, (6) dispute resolution, (7) regional participation, (8) economic planning studies, and (9) cost allocation for new projects. 5

7 Types of Planning Studies NERC/WECC Reliability Studies meet NERC/WECC standards and coordination through CCPG. Sub-regional Coordination (CCPG) - identify congestion and overloads and address integration of new resources and loads Ten Year Transmission Study evaluates the system to ensure we can serve our customers requirements/load growth Generator Interconnection and Transmission Service Requests

8 Types of Planning Studies» Western invites the stakeholders to submit any transmission study requests for review and discussion»western s point of contact for study requests is rmrplanningmanager@wapa.gov.

9 Western s Service Territory

10 WestConnect Transmission Planning Update Bob Easton 890 Stakeholder Meeting June 23, 2014

11 WestConnect Planning Footprint Quick Facts Touches 11 Western States 9.8 Million Retail Customers 56,000 MW Demand 39,000 Miles of Transmission 1.7 Million Miles 2 2

12 Regional Planning Groups Footprint WECC Subregional Planning Groups Major Transmission Facilities ColumbiaGrid Northern Tier Transmission Group (NTTG) BC Coordinated Planning and Alberta System Operator that are not part of ColumbiaGrid or NTTG WestConnect (SWAT, CCPG & SPPG) California ISO California Transmission Planning Group that are not part of CAISO Other Facilities 3

13 Parties to WestConnect STP Project Agreement Arizona Public Service Company Basin Electric Power Cooperative Black Hills Corporation El Paso Electric Company Imperial Irrigation District Platte River Power Authority Public Service Company of CO Public Service Company of NM Sacramento Municipal Utility District Salt River Project NV Energy Southwest Transmission Cooperative Transmission Agency of Northern California Tri-State Generation & Transmission, Assoc. Tucson Electric Power Company Western Area Power Administration Los Angeles Department of Water and Power 4

14 WestConnect Subregional Planning Groups CCPG, SSPG and SWAT are technical planning work groups within the WestConnect Footprint Coordinate Information for use by all study participants operate under Charters Define subregional study plans, provide study resources, and perform studies Provide forum for coordination and peer review of planning studies and 10-year plans SSPG Sierra Subregional Planning Group SWAT Southwest Area Transmission CCPG Colorado Coordinated Planning Group 5

15 2014 SCOPE of Work Manage Annual Planning Process Update the 10-Yr Planning Documents Participate in WECC TEPPC Coordinate WestConnect-wide 10-Yr Base Case OPTIONAL Coordinate with SCG (RCG now) 6

16 2014 SCOPE of Work Attend CCPG/SWAT/SSPG Joint Meeting August Tri-State Maintain TPM Database Participate in FERC Order 1000 Filing Strike Teams Much Work on Business Practice Manual and Planning Participation Agreement 7

17 Western Interconnection Planning Process RCG Process Coordination Among STPs 8

18 WestConnect Synchronized Planning Cycle TEPPC Economic Study Results For WestConnect Footprint 2014 Planning Cycle 11/20/14 Workshop SPG Study Results Future Study Needs Planning Report Prep. 3 mo. Study Plans Dev. Publish 10 Yr Plans Approve 2014 Trans. Reports 2015 Study Plans 2/19/15 Annual Mtg 2014 Planning Cycle WestConnect Economic Study Request of TEPPC Coordination / collaboration with Regional Planning Coordination Group (RCG)

19 Western RMR Transmission Planning Stakeholder Meeting 2014 Transmission Planning Studies Jim Hirning Transmission Planner Loveland, CO June 23,

20 NERC/WECC Transmission Planning TPL-001, -002, -003, -004 Ensure system is adequate to meet present and future needs Demonstrate through assessment Planning for near and long term Cover all demand levels over range of forecast demands Include existing and planned facilities Ensure adequate reactive resources 2

21 CCPG Colorado Coordinated Planning Group Eight Member Utilities Basin Electric Power Cooperative Black Hills Corporation Colorado Springs Utilities PacifiCorp Platte River Power Authority Public Service Company of Colorado (Xcel Energy) Tri-State Generation & Transmission Assoc. Western Area Power Administration-RMR 3

22 Yellowtail CCPG Footprint Thermopolis Buffalo Wyodak Osage Lange Rapid City (DC Terminal) Riverton Casper Spence Platte Jim Bridger Dave Johnston Laramie River Stegall (DC Terminal) Archer Sidney (DC Terminal) To Ashley To Upalco To Mona Flaming Gorge Vernal Bonanza Meeker Craig Hayden Gore Pass Ault Ft. St. Vrain Pawnee Story N. Yuma Rifle Cherokee Big Sandy Burlington Malta Midway Montrose Curecanti Poncha Lost Canyon Boone Comanche Lamar (DC Terminal) Hesperus Trinidad To To San Juan To Glade

23 2011 NERC/WECC Compliance Report Performed Annually Area Studied Colorado Wyoming Western Nebraska Western South Dakota 5

24 Purpose Evaluate the steady state post-contingency response of the Integrated System Evaluate transient and voltage stability Identify problem areas due to system load growth Meet NERC/WECC Transmission Planning Standards 6

25 Study Procedure CCPG Compliance Study Cases To Be Examined 2019 Heavy Winter 2019 Light Winter 2019 Light Winter High Renewables 2025 Heavy Summer System Intact Criteria 100% Continuous Rating Loading 0.95 p.u p.u. Voltage Contingency Analysis Criteria 100% Continuous/Emergency Rating Loading 0.90 p.u p.u. Voltage 7

26 Questions Any Questions or Comments? 8

27 2014 Transmission Planning Study Jason Parker Planning Engineer June 23, 2014

28 Objectives Western will provide reliable, value driven service to preferential customers. To maintain compliance with NERC and Western standards. Evaluate the load serving capability of the integrated system while preserving TOT path capacities. Scope, schedule and prioritize Western transmission and substation system projects for inclusion in the Capital Improvement Plan (CIP).

29 Process Loads Request and receive load data from network customers Jan-March 2014 Power Flows Develop base cases March-April 2014 Projects Analyze power flow results Study solutions Report May-July 2014 Inclusion in Capital Improvement Plan Preliminary Scope and Estimates Aug-November 2014 Stakeholders Present study results at Quarterly Stakeholders Meeting December 2014

30 Process Improvements Annual Study Guidelines created and implemented for the Rocky Mountain Region and Desert Southwest Region. Coordination of study cases with the Desert Southwest, utilizing the same seed case such that all updates for DSW and RMR are in the same cases. Study Processes: Study focused on Network Customer load forecasts and scheduled system improvements. Alternate study focused on Network Customer load and no system improvements.

31 Study Criteria WECC approved cases: 2019 Heavy Summer 2024 Heavy Winter 2019 Heavy Summer case study will include post transient and transient analysis where applicable and study without scheduled system additions.

32 Study Criteria Criteria System Intact 0.95 p.u p.u. Voltage 100% Continuous Loading Rate Contingency 0.90 p.u p.u. Voltage 100% Continuous Rating or Emergency Limit Contingency Analysis N-1, N-2 Monitored integrated system and adjacent area. Transformer emergency rating-120% of normal thermal rating.

33 Study Criteria Stress Levels applied to cases: TOT 1A, WECC Path MW East-West, 2019 HS YTS 625 MW North-South, 2024 HW

34 Study Criteria Studies based on network customer projections 5 & 10 years in the future. Voltage and thermal issues that appear for the first time will be monitored for recurrence. Voltage and thermal issues that repeatedly appear may be studied as a sensitivity study and result in a change of the corrective action plan and Capital Improvement Plan.

35 Upcoming Events Analysis of studies. Compilation and ranking of proposed capital budget items. Desert Southwest and Rocky Mountain Region combined 2014 Ten Year Annual Report.

36 Questions?

37 Big Horn Basin Area Study Susan Franklin Facilities & Construction June 23, 2014

38 The Big Picture

39 The Big Horn Basin Study Area

40 Items of Interest Generation patterns from a planning perspective 69 kv voltages, high vs. low 69 kv thermal limitations 115 kv line loading for N-1 contingencies Load growth accommodation of solutions

41 Generation Patterns Generation and impact on voltage Buffalo Bill-3 units One unit active at minimum levels in winter Sprit Mountain-1 unit Seasonal when irrigation is available Shoshone-1 unit Active at minimum levels in winter Heart Mountain-1 unit Seasonal when irrigation is available Drought-minimum levels of 1 MW total 30.5 MW maximum generation

42 69 kv Voltages Studies have indicated low 69 and 115 kv voltages for many N-1 outages studied in the past three Annual Studies. Real time reports of high voltages at Heart Mountain, Lovell, and Big George 69 kv buses for system in-tact. Research existing facilities and update the power flow base case. Generation bus voltage targets Generation step up transformer taps LV and BGG 115/69 kv transformer taps YT 230/115 kv transformer taps TH 230/115 kv transformer taps Load confirmation

43 69 kv Voltage Profiles

44 What Is Impacting the V System In-tact? Generation Facilities Bus voltage targets have changed due to issues within the power plants, resulting in nominal to boosting tap settings on the generator step-up transformers Lovell and Big George 115/69 kv transformer tap settings Boosting the 69 kv voltage 2.5% Yellowtail and Thermopolis 230/115 kv transformer tap and LTC settings Boosting the 115 kv voltage 2.5% High generation and light loads result in higher voltages

45 Which Outages are Impacting the V? Outage of any of these elements result in low 69 kv voltages: Lovell 115/69 kv transformer Big George 115/69 kv transformer Lovell-Garland 69 kv Line Big George-Glendale Tap 69 kv Line Heart Mountain-Glendale Tap 69 kv Line Big George-North Cody 69 kv Line

46 69 kv Limitations Two sources: 115/69 kv 50 MVA transformers 60 MVA line capacity limits on the 69 kv system Variable 69 kv generation

47 69 kv Solutions Add a THIRD 115/69 kv Source at North Cody Existing ROW Substation space available at load center

48 69 kv Cost Estimates (Preliminary) Big George-Heart Mountain 115 kv Circuit and Heart Mountain-North Cody 115 kv Conversion Big George Substation work North Cody Transformer and Sub Work TOTAL: $4,940,000 Target In-service Date: 2016

49 115 kv Lines System in-tact-acceptable performance N-1 contingency of three outages result in an overload on the Basin- Worland Tap 115 kv line Options Studied: 2 nd Yellowtail-PACE Yellowtail 230 kv line Tie PACE Yellowtail-Sheridan 230 kv line into Crossover 230 substation as 2 nd tie to the PACE Yellowtail 230 kv system Continue Re-conductor from Lovell to Worland Tap 115 kv line

50 115 kv Cost Estimates (Preliminary) The recommendation is the continuation of the LV- BA115 kv line re-conductor, extending the project from Basin to Worland Tap, 15 miles. Basin-Worland Tap 115 kv Line Re-conductor $2,000,000 Target In-service Date: 2016

51 Yellowtail South: 625 MW to 700 MW Completion of the following projects: Lovell-Yellowtail #1 & #2 Line Rebuild Lovell-Nahne Jensen-Basin 115 kv Re-Conductor New Basin-Worland Tap 115 kv Re-Conductor Capacitor Banks for voltage support

52 Big Horn Basin Load Growth Forecasted Load Growth 69 kv System: 1-1.6% 115 kv System: % North Cody Substation and 115 kv line project accommodates expected load growth beyond the twenty year window.

53 Questions? Contact Susan Franklin

54 Western Rocky Mountain Region FY14 Major Capital Program Overview Prepared by Susan Franklin 23 June 2014

55 TRANSMISSION Pick Sloan CRSP

56 PICK SLOAN MAJOR CAPITAL TRANSMISSION PROJECTS Transmission Lines Basin-Lovell 115-kV uprate Big George-Heart Mountain 69-kV Reconductor Estes-Flatiron 115-kV Rebuild Gem City-Snowy 115-kV Rebuild Granby-Windy Gap 138/69-kV Rebuild-Trust Goshen-Torrington uprate to 115-kV Line Switch Replacements- Eastern Colorado, Wyoming, Nebraska Transmission Line Programs Lovell-Yellowtail

57 PICK SLOAN TRANSMISSION LINES Basin-Lovell 115-kV uprate Reconductor 35 miles of line with 477 ACSS and add one overhead fiber optic ground wire Estimated Project Cost: $ 6,915K ISD 2015 Big George-Heart Mountain 69-kV Reconductor Reconductor 6 miles of line with 477 ACSR Estimated Project Cost: $ 790K ISD 2014 Estes-Flatiron115-kV Rebuild 16 miles each, Double Circuit Steel or Wood-H Estimated Budget: $19,300k ISD Gem City-Snowy 115-kV Rebuild 1.2 miles, Wood H Estimated Budget: $ 750k ISD 2014

58 PICK SLOAN TRANSMISSION LINES Granby Pumping Plant-Windy Gap 138/69-kV Rebuild-TRUST 12 miles, Double Circuit Steel Estimated Budget: $18,800k ISD 2015 Goshen-Torrington Rebuild (PVVC) Rebuild 6.5 miles at 115-kV Estimated Budget: $ 2,080 ISD 2016

59 PICK SLOAN 115-KV LINE SWITCH REPLACEMENTS Wyoming Glendale Tap Estimated Budget: $625k ISD: FY14

60 LOVELL-YELLOWTAIL PROGRAM Phase 1 National Park Service (NPS)-Complete Phase 2 Area outside of the NPS and the Crow Reservation-Complete Phase 3 Crow Reservation Phase 1, 2, 3 were initiated due to age and condition 115-kV construction with 795 ACSS conductor. Line rating will be 330 MW each

61 LOVELL-YELLOWTAIL REBUILDS Phase 1 National Park Service only. Scope : Project to rebuild the LV-YT 115-kV #1 and #2 lines. Each are 15 miles (30 miles total) Estimated Budget: $14,186k ISD: FY13 Status: Complete Phase 2 Outside of the NPS and the Crow Reservation Scope : Project to rebuild the LV-YT 115-kV #1 and #2 lines. Each are 16 miles (32 miles total). Estimated Budget: $6,922k Start: FY13 ISD: FY14 Status: Complete Phase 3 Crow Reservation Scope : Project to rebuild the LV-YT 115-kV #1 and #2 lines. Each are 15 miles (30 miles total). Estimated Budget: $8,646k Start: FY14 ISD: FY Negotiations Ongoing

62 CRSP TRANSMISSION LINE PROJECTS Pleasant View 24.9-kV Line Replacement Budget: $661k FY16

63 SUBSTATION Pick Sloan CRSP

64 MAJOR PICK SLOAN SUB/SWITCHYARD PROJECTS Cheyenne Stage 4: 2 nd 230/115 kv, 200 MVA Transformer Addition Gering Substation: 115 kv, 30 MVAR Cap Bank Goshen County New 230/115 kv Substation-PVVC Laramie Substation New 115 kv, 8.1 MVAR Cap Bank Pilot Butte New 115 kv, 15 MVAR Cap Bank-Trust Stegall KV1A 230/115 kv, 167 MVA Transformer Replacement Stegall Replace 21 MAR Reactor and Breaker

65 MAJOR PICK SLOAN SUB/SWITCHYARD PROJECTS Cheyenne Stage 4: 2 nd 230/115 kv, 200 MVA Transformer Addition Install 2 nd 230/115 kv, 200 MVA Transformer Estimated Project Cost: $ 4,038K ISD 2014 Gering Substation: 115 kv, 30 MVAR Cap Bank Install single step 30 MVAR Cap bank Estimated Project Cost: $ 1,005K ISD 2015 Goshen County New 230/115 kv Substation-PVVC Install new 230/115 kv substation for PVVC Estimated Budget: $13,660k ISD 2016 Laramie Substation New 115 kv, 8.1 MVAR Cap Bank 1.2 miles, Wood H Estimated Budget: $ 814k ISD 2014

66 MAJOR PICK SLOAN SUB/SWITCHYARD PROJECTS Pilot Butte New 115 kv, 15 MVAR Cap Bank Install 2 nd 15 MVAR Cap Bank on the 115 kv Bus Estimated Project Cost: $ 1,000K ISD 2015 Stegall KV1A 230/115 kv 167 MVA Transformer Replacement Replace 100 MVA with 167 MVA Estimated Project Cost: $ 3,965K ISD 2015 Stegall Replace KW1A, KW2A, 21 MAR Reactor and Breaker Replace failed/end of life reactors and breaker on 13.8 kv tertiary Estimated Project Cost: $ 875K ISD 2015

67 MAJOR CRSP SUB/SWITCHYARD PROJECTS Archer KV1A 230/115/13.8-kV 200 MVA Transformer Replacement Ault 345 kv Breaker Replacements (692, 696, 1096)-Trust Curecanti KZ1A 230/115 kv, 150 MVA Transformer Replacement Hayden KY2A 230/115 kv, 250 MVA Transformer Replacement Waterflow Phase Shifter Replacement KU1A and KU1B

68 MAJOR CRSP SUB/SWITCHYARD PROJECTS Archer KV1A 230/115/13.8-kV 200 MVA Transformer Replacement Replace failed 167 MVA with 200 MVA Estimated Project Cost: $ 3,158K ISD 2014 Ault 345 kv Breaker Replacements (692, 696, 1096)-Trust/Joint Replace 345 kv Breakers 692, 969, 1096 Estimated Project Cost: $ 2,210K ISD 2015 Curecanti KZ1A 230/115 kv, 150 MVA Transformer Replacement Replace 75 MVA with HDN KZ2A 150 MVA Estimated Budget: $3,400k ISD 2016 Hayden KY2A 230/115 kv, 250 MVA Transformer Replacement Replace 150 MVA with a 250 MVA transformer Estimated Budget: $ 6,653k ISD 2015 Waterflow Phase Shifter Replacement KU1A and KU1B Replace failed KU1A and KU1B phase shifting transformers Estimated Budget: $ 14,275k ISD 2016

69 WESTERN RMR MAJOR CAPITAL PROGRAM FY14 Questions? Contact Susan Franklin Facilities & Construction

MEETING AGENDA. Western Area Power Administration Rocky Mountain Region. Transmission Planning Stakeholder Meeting

MEETING AGENDA. Western Area Power Administration Rocky Mountain Region. Transmission Planning Stakeholder Meeting MEETING AGENDA Western Area Power Administration Rocky Mountain Region Transmission Planning Stakeholder Meeting Western s RMR Regional Office 5555 East Crossroads Boulevard, Loveland, CO 80538 December

More information

Tri-State December 2013 Board Meeting

Tri-State December 2013 Board Meeting 1 For more information Tri-State webpage: www.tristategt.org click Operations then Transmission Planning (http://www.tristategt.org/transmissionplanning/puc3627_trans missionprojects.cfm) Email: (transmissionplanning@tristategt.org)

More information

Western Area Power Administration Rocky Mountain Region (LAPT) Network Integrated Transmission Service. Designated Network Resources

Western Area Power Administration Rocky Mountain Region (LAPT) Network Integrated Transmission Service. Designated Network Resources Customer Name Basin Electric Cheyenne Power and Light City of Fort Morgan & Estimated Maximum Resource MW Point of Receipt Delivering Party & Voltage Antelope Valley 2 Yellowtail Basin Electric 115 kv

More information

Transmission Coordination and Planning Committee 2016 Q4 Stakeholder Meeting

Transmission Coordination and Planning Committee 2016 Q4 Stakeholder Meeting Transmission Coordination and Planning Committee 2016 Q4 Stakeholder Meeting BHE Wyoming Q4 Stakeholder Meeting November 17, 2016 @ 1:00PM MT Black Hills Energy Service Center 409 Deadwood Avenue, Rapid

More information

Consulting Agreement Study. Completed for Transmission Customer

Consulting Agreement Study. Completed for Transmission Customer Completed for Transmission Customer Proposed Resource & Transmission Carbon County, MT & 230 kv Transmission in North Wyoming August 2016 Table of Contents 1.0 Description... 1 2.0 Overall Assumptions...

More information

Western Area Power Administration Rocky Mountain Region Annual Progress Report. Projects. Weld Substation Stage 04

Western Area Power Administration Rocky Mountain Region Annual Progress Report. Projects. Weld Substation Stage 04 Western Area Power Administration Rocky Mountain Region 2014 Annual Progress Report Projects Weld Substation Stage 04 Lovell Yellowtail 115-kV rebuild Curecanti 230/115-kV 150 MVA transformer Terry Ranch

More information

WestConnect Regional Planning Update

WestConnect Regional Planning Update WestConnect Regional Planning Update WRP Energy Committee May 4, 2015 Webinar Outline WestConnect Overview Membership, Structure & Footprint Planning process and regulatory status Order 890 Update (2014)

More information

WestConnect Regional Transmission Service. Presentation to ISAS September 26, 2017

WestConnect Regional Transmission Service. Presentation to ISAS September 26, 2017 WestConnect Regional Transmission Service Presentation to ISAS September 26, 2017 WestConnect Regional Transmission Service FERC Tariff based Accepted July 1, 2013 Based on a Participation Agreement with

More information

Transmission Coordination and Planning Committee 2014 Q4 Stakeholder Meeting. December 18, 2014

Transmission Coordination and Planning Committee 2014 Q4 Stakeholder Meeting. December 18, 2014 Transmission Coordination and Planning Committee 2014 Q4 Stakeholder Meeting December 18, 2014 Agenda 1. Introductions 2. TCPC Policies 3. BHCE Planning Department Update 4. 2014 LTP Study Results 5. Stakeholder

More information

PSE Attachment K Puget Sound Area Transmission Meeting

PSE Attachment K Puget Sound Area Transmission Meeting PSE Attachment K Puget Sound Area Transmission Meeting Stephanie Lu Senior Engineer December 15, 2011 Agenda Attachment K Review Economic Studies Process PSE Planning Process and Assumptions PSE Projects

More information

PSCo 10-Year Transmission Plan/20-Year Scenario Assessment

PSCo 10-Year Transmission Plan/20-Year Scenario Assessment PSCo 10-Year Transmission Plan/20-Year Scenario Assessment May 2009 This report contains transmission planning data that may be conceptual in nature and is subject to change. The transmission projects

More information

Elbert County 500 MW Generation Addition Interconnection Feasibility Study Report OASIS POSTING # GI

Elbert County 500 MW Generation Addition Interconnection Feasibility Study Report OASIS POSTING # GI Executive Summary Elbert County 500 MW Generation Addition Interconnection Feasibility Study Report OASIS POSTING # GI-2003-2 Xcel Energy Transmission Planning January 2004 This Interconnection Feasibility

More information

Updates. Pat Reiten President and CEO, PacifiCorp Transmission

Updates. Pat Reiten President and CEO, PacifiCorp Transmission PacifiCorp Transmission and Regional Updates Pat Reiten President and CEO, PacifiCorp Transmission PacifiCorp Transmission Overview 16,400 circuit-miles of transmission lines 12,685 MW record peak demand

More information

Falcon-Midway 115 kv Line Uprate Project Report

Falcon-Midway 115 kv Line Uprate Project Report Falcon-Midway 115 kv Line Uprate Project Report 12/1/2008 1 Background The function of this project is to uprate the 26.7 miles of Tri-State s 115 kv line between Midway and Falcon substations from 50

More information

Public Service Company of Colorado Transmission Projects Status. CCPG May 5, 2016

Public Service Company of Colorado Transmission Projects Status. CCPG May 5, 2016 Public Service Company of Colorado Transmission Projects Status CCPG May 5, 2016 1 Transmission Ownership Colorado 2016 Transmission Planning Drivers Load Service / Near-Term (1-5 years) TPL Studies (5

More information

SPS Planning Criteria and Study Methodology

SPS Planning Criteria and Study Methodology SPS Planning Criteria and Study Methodology SPS subscribes to the Southwest Power Pool ("SPP") Reliability Criteria, which incorporates compliance with the appropriate North American Electric Reliability

More information

Rocky Mountain Power Exhibit RMP (RAV-4SD) Docket No Witness: Rick A. Vail BEFORE THE PUBLIC SERVICE COMMISSION OF THE STATE OF UTAH

Rocky Mountain Power Exhibit RMP (RAV-4SD) Docket No Witness: Rick A. Vail BEFORE THE PUBLIC SERVICE COMMISSION OF THE STATE OF UTAH Rocky Mountain Power Exhibit RMP (RAV-4SD) Docket No. 17-035-40 Witness: Rick A. Vail BEFORE THE PUBLIC SERVICE COMMISSION OF THE STATE OF UTAH ROCKY MOUNTAIN POWER Exhibit Accompanying Supplemental Direct

More information

Transmission Planning Attachment K Public Input Meeting

Transmission Planning Attachment K Public Input Meeting Transmission Planning Attachment K Public Input Meeting FERC 890 6 th Quarter Meeting May 25, 2011 Agenda Mountain Time Topic Presenter 1:00 1:15 Greetings and Introduction Dennis Desmarais 1:15 1:30 Attachment

More information

Interconnection System Impact Study Report Request # GI

Interconnection System Impact Study Report Request # GI Executive Summary Interconnection System Impact Study Report Request # GI-2008-23 34 MW Solar Generation Ranch at Hartsel, Colorado Public Service Company of Colorado Transmission Planning August 19, 2010

More information

Capital Investment Plan

Capital Investment Plan Capital Investment Plan 2009-2018 ROCKY MOUNTAIN REGION FY2009.02 TABLE OF CONTENTS 1 INTRODUCTION... 3 2 COLORADO RIVER STORAGE PROJECT (CRSP) PROGRAM OVERVIEW... 6 2.1 CRSP FY08 Accomplishments and Notable

More information

Gateway South Transmission Project

Gateway South Transmission Project Phase 1 Comprehensive Progress Report Volume 1 - Technical Report Report Prepared by PacifiCorp Transmission Planning Department November 21, 2008 WECC1-V4 Phase 1 Comprehensive Progress Report Executive

More information

Black Hills Project Summary

Black Hills Project Summary 2016 Rule 3627 Report Black Hills Project Summary Page 1 of 38 Black Hills Project Summary Colorado PUC E-Filings System D 1 2016 Rule 3627 Report Black Hills Project Summary Page 2 of 38 Category Transmission

More information

Interconnection System Impact Study Final Report February 19, 2018

Interconnection System Impact Study Final Report February 19, 2018 Interconnection System Impact Study Final Report February 19, 2018 Generator Interconnection Request No. TI-17-0225 248.4 MW (Alternate Project Output of 217.35 MW) Wind Energy Generating Facility In Goshen

More information

Appendix D Black Hills Project Summary

Appendix D Black Hills Project Summary Page 1 of 28 Appendix D Black Hills Project Summary Table of Contents Black Hills Project Summary... D-1 Boone-Nyberg 115 kv Project... D-3 Rattlesnake Butte 115 kv Substation Terminal... D-6 Fountain

More information

Transmission Competitive Solicitation Questions Log Question / Answer Matrix Harry Allen to Eldorado 2015

Transmission Competitive Solicitation Questions Log Question / Answer Matrix Harry Allen to Eldorado 2015 No. Comment Submitted ISO Response Date Q&A Posted 1 Will the ISO consider proposals that are not within the impedance range specified? Yes. However, the benefits estimated and studies performed by the

More information

Proposed Incorporation of Merced Irrigation District into ISO Balancing Authority Area in Stakeholder Webconference February 28, 2013

Proposed Incorporation of Merced Irrigation District into ISO Balancing Authority Area in Stakeholder Webconference February 28, 2013 Proposed Incorporation of Merced Irrigation District into ISO Balancing Authority Area in 2015 Stakeholder Webconference February 28, 2013 Page 2 Merced Irrigation District (Merced) Background Merced Irrigation

More information

TransWest Express Transmission AC and DC Project Interregional Transmission Project Submittal

TransWest Express Transmission AC and DC Project Interregional Transmission Project Submittal TransWest Express Transmission AC and DC Project 2018 2019 Interregional Transmission Project Submittal Submittals to California Independent System Operator, WestConnect and Northern Tier Transmission

More information

Interconnection Feasibility Study Report Request # GI Draft Report 600 MW Wind Generating Facility Missile Site 230 kv Substation, Colorado

Interconnection Feasibility Study Report Request # GI Draft Report 600 MW Wind Generating Facility Missile Site 230 kv Substation, Colorado Executive Summary Interconnection Feasibility Study Report Request # GI-2016-6 Draft Report 600 MW Wind Generating Facility Missile Site 230 kv Substation, Colorado Public Service Company of Colorado Transmission

More information

Large Load Serving Study Report for La Plata Electric Association, Inc. Alternatives. Addendum. San Juan Major Project

Large Load Serving Study Report for La Plata Electric Association, Inc. Alternatives. Addendum. San Juan Major Project Large Load Serving Study Report for La Plata Electric Association, Inc. Alternatives Addendum San Juan Major Project Tri-State Generation and Transmission Association Power System Planning December, 2008

More information

APPENDIX F: Project Need and Description

APPENDIX F: Project Need and Description APPENDIX F: Project Need and Description California ISO/MID F-1 Intentionally left blank California ISO/MID F-2 Name Brief Description Type Lugo Victorville 500 kv Upgrade (SCE portion) The project was

More information

THE NECESSITY OF THE 500 KV SYSTEM IN NWE S TRANSMISSION SYSTEM TO MAINTAIN RELIABLE SERVICE TO MONTANA CUSTOMERS

THE NECESSITY OF THE 500 KV SYSTEM IN NWE S TRANSMISSION SYSTEM TO MAINTAIN RELIABLE SERVICE TO MONTANA CUSTOMERS THE NECESSITY OF THE 500 KV SYSTEM IN NWE S TRANSMISSION SYSTEM TO MAINTAIN RELIABLE SERVICE TO MONTANA CUSTOMERS 2/27/2018 ELECTRIC TRANSMISSION PLANNING Table of Contents Table of Contents... 2 Executive

More information

Arizona Transmission Challenges

Arizona Transmission Challenges Power Task Force Agenda Number 2. Arizona Transmission Challenges Central Arizona Water Conservation District Power Committee Presentation May 18, 2017 Transmission Planning Efforts NATIONAL Section 368

More information

2012 LOCAL TRANSMISSION PLAN:

2012 LOCAL TRANSMISSION PLAN: Colorado PUC E-Filings System 2012 LOCAL TRANSMISSION PLAN: TRANSMISSION COORDINATION AND PLANNING COMMITTEE ANNUAL TRANSMISSION ASSESSMENT FOR BLACK HILLS/COLORADO ELECTRIC UTILITY COMPANY, L.P., D/B/A

More information

System Impact Study Report Request # T MW Firm Point-to-Point Transmission Service Request from Wyoming to Colorado

System Impact Study Report Request # T MW Firm Point-to-Point Transmission Service Request from Wyoming to Colorado System Impact Study T-2007-3 Final.doc System Impact Study Report Request # T-2007-3 900 MW Firm Point-to-Point Transmission Service Request from Wyoming to Colorado Executive Summary PSCo Transmission

More information

March 18, Subject: Imperial Irrigation District 2014 Annual Progress Report - Rev 1

March 18, Subject: Imperial Irrigation District 2014 Annual Progress Report - Rev 1 Energy Division P.O. Box 937 333 E. Barioni Blvd. Imperial, CA 92251 www.iid.com March 18, 2014 Mr. Tracy Rolstad Chair, WECC Technical Studies Subcommittee Senior Power System Consultant Avista System

More information

Transmission Planning & Engineering P.O. Box MS 3259 Phoenix, Arizona

Transmission Planning & Engineering P.O. Box MS 3259 Phoenix, Arizona Transmission Planning & Engineering P.O. Box 53933 MS 3259 Phoenix, Arizona 85072-3933 March 9, 2016 Mr. Philip Augustin Chair, WECC Technical Studies Subcommittee Mr. Enoch Davies WECC Technical Staff

More information

Decision on Merced Irrigation District Transition Agreement

Decision on Merced Irrigation District Transition Agreement California Independent System Operator Corporation Memorandum To: ISO Board of Governors From: Karen Edson, Vice President Policy & Client Services Date: March 13, 2013 Re: Decision on Merced Irrigation

More information

Attached is Idaho Power s 2013 WECC Annual Progress Report. Please contact me if you have any questions.

Attached is Idaho Power s 2013 WECC Annual Progress Report. Please contact me if you have any questions. March 8, 2013 David Franklin Chair, Technical Studies Subcommittee Southern California Edison 1 Innovation Way Pomona, CA 91768 MHanson@idahopower.com (208) 388-2253 Enoch Davies Western Electricity Coordinating

More information

Western Area Power Administration

Western Area Power Administration 2014/15 Integrated System (IS) 890 Local Planning Stakeholder Meeting #2 Western Area Power Administration Upper Great Plains Region Transmission Planning Stakeholder Meeting Wednesday, December 10 th,

More information

Wholesale Power Supply Socorro Electric Cooperative, Inc. Rob Wolaver, P.E. Senior Manager, Energy Resources

Wholesale Power Supply Socorro Electric Cooperative, Inc. Rob Wolaver, P.E. Senior Manager, Energy Resources Wholesale Power Supply Socorro Electric Cooperative, Inc. Rob Wolaver, P.E. Senior Manager, Energy Resources Outline Tri-State Background Tri-State Generation Mix Power Delivery Wholesale Electricity Markets

More information

Managing California s Electrical Supply System after the shut down of San Onofre Nuclear Generating Station

Managing California s Electrical Supply System after the shut down of San Onofre Nuclear Generating Station Managing California s Electrical Supply System after the shut down of San Onofre Nuclear Generating Station East Asian Alternative Energy Futures Workshop By the Nonproliferation Policy Education Center

More information

Status of PNM s Completed Transmission Construction Projects 11/30/2017

Status of PNM s Completed Transmission Construction Projects 11/30/2017 Status of s Completed Transmission Construction Projects Second Tah Ta Hey 115/345 kv Transformer Yah Ta Hey Switching Station On January 9, 2015, filed with the NMPRC under NMPRC Rule 440 information

More information

Rocky Mountain Power Five Year Study Findings & Kick Off Meeting

Rocky Mountain Power Five Year Study Findings & Kick Off Meeting 2000 PACIFICORP PAGE 1 Attachment K Rocky Mountain Power Five Year Study Findings & Kick Off Meeting Thursday, December 8 2016 2000 PACIFICORP PAGE 2 Study Areas for 2016 Findings Reports Southeast, Utah

More information

Memorandum. This memorandum requires Board action. EXECUTIVE SUMMARY

Memorandum. This memorandum requires Board action. EXECUTIVE SUMMARY California Independent System Operator Memorandum To: ISO Operations (MRTU) Committee From: Armando J. Perez, Director of Grid Planning cc: ISO Board of Governors ISO Officers Date: April 29, 2005 Re:

More information

100 MW Wind Generation Project

100 MW Wind Generation Project A subsidiary of Pinnacle West Capital Corporation 100 MW Wind Generation Project CUSTOMER FINAL Feasibility Study Results By Transmission Planning, APS December 21, 2007 Executive Summary This Feasibility

More information

West Station-West Cañon 115 kv Transmission Project

West Station-West Cañon 115 kv Transmission Project West Station-West Cañon 115 kv Transmission Project Project Sponsor: Additional Project Participants: Project Description: Black Hills Colorado Electric New 115 kv line from West Station to West Cañon

More information

Supplemental Report on the NCTPC Collaborative Transmission Plan

Supplemental Report on the NCTPC Collaborative Transmission Plan Supplemental Report on the NCTPC 2007-2017 Collaborative Transmission Plan May 16, 2008 1 Table of Contents I. Executive Summary...1 II. Richmond-Fort Bragg Woodruff Street 230 kv Line...2 II.A. Need for

More information

SERTP rd Quarter Meeting

SERTP rd Quarter Meeting 2014 SERTP SERTP 2014 3 rd Quarter Meeting 2 nd RPSG Meeting September 30 th, 2014 APC Headquarters Birmingham, AL 2014 SERTP Process Information The SERTP process is a transmission planning process. Please

More information

Merger of the generator interconnection processes of Valley Electric and the ISO;

Merger of the generator interconnection processes of Valley Electric and the ISO; California Independent System Operator Corporation Memorandum To: ISO Board of Governors From: Karen Edson Vice President, Policy & Client Services Date: August 18, 2011 Re: Decision on Valley Electric

More information

SERTP rd Quarter Meeting

SERTP rd Quarter Meeting 2015 SERTP SERTP 2015 3 rd Quarter Meeting 2nd RPSG Meeting September 24 th, 2015 APC Headquarters Birmingham, AL 2015 SERTP Process Information The SERTP process is a transmission planning process. Please

More information

Public Service Company of Colorado System Impact Study Load Interconnection Request for a 50 MVA Load Near Collbran

Public Service Company of Colorado System Impact Study Load Interconnection Request for a 50 MVA Load Near Collbran System Impact Study_50 MVA Load Interconnnection Request Near Collbran.doc Public Service Company of Colorado System Impact Study Load Interconnection Request for a 50 MVA Load Near Collbran PSCo Transmission

More information

Service Requested 150 MW, Firm. Table ES.1: Summary Details for TSR #

Service Requested 150 MW, Firm. Table ES.1: Summary Details for TSR # Executive Summary Firm point to point transmission service has been requested by Transmission Service Request (TSR) #75669514, under the SaskPower Open Access Transmission Tariff (OATT). The TSR consists

More information

2013 ANNUAL PROGRESS REPORT

2013 ANNUAL PROGRESS REPORT March 1, 2013 Mr. David Franklin, Chairman WECC Technical Studies Subcommittee Southern California Edison 1 Innovation Way Pomona, CA 91768-2560 Mr. Enoch Davies WECC Technical Staff 155 North 400 West,

More information

BEFORE THE PUBLIC UTILITIES COMMISSION OF THE STATE OF COLORADO DIRECT TESTIMONY AND EXHIBITS OF CHRISTOPHER E. PINK TABLE OF CONTENTS

BEFORE THE PUBLIC UTILITIES COMMISSION OF THE STATE OF COLORADO DIRECT TESTIMONY AND EXHIBITS OF CHRISTOPHER E. PINK TABLE OF CONTENTS BEFORE THE PUBLIC UTILITIES COMMISSION OF THE STATE OF COLORADO IN THE MATTER OF THE APPLICATION OF TRI-STATE GENERATION AND TRANSMISSION ASSOCIATION, INC. FOR A CERTIFICATE OF PUBLIC CONVENIENCE AND NECESSITY

More information

Alberta Electric System Operator Needs Identification Document Application. Mowat 2033S Substation

Alberta Electric System Operator Needs Identification Document Application. Mowat 2033S Substation Decision 21781-D01-2016 Alberta Electric System Operator Needs Identification Document Application Facility Applications September 7, 2016 Alberta Utilities Commission Decision 21781-D01-2016: Alberta

More information

Public Service Company of Colorado Transmission Projects Status. CCPG August 18, 2016

Public Service Company of Colorado Transmission Projects Status. CCPG August 18, 2016 Public Service Company of Colorado Transmission Projects Status CCPG August 18, 2016 1 Transmission Ownership Colorado 2016 Generation Additions/Reductions Name Interconnection Owner Net MW Type ISD Zuni

More information

TOT1A: Metering Point Relocation Comprehensive Progress Report (WECC Path 30)

TOT1A: Metering Point Relocation Comprehensive Progress Report (WECC Path 30) TOT1A: Metering Point Relocation Comprehensive Progress Report (WECC Path 30) Submitted to TOT1A Stakeholders and TOT1A Interconnected Utilities And Western Electricity Coordinating Council June 6, 2013

More information

Proposed New Construction for

Proposed New Construction for Tri-State Generation and Transmission Association, Inc. Colorado PUC E-Filings System Proposed New Construction for 2016 2019 Colorado PUC Rule 3206 Application April 28, 2016 TABLE OF CONTENTS A) Projects

More information

TransWest Express Project

TransWest Express Project TransWest Express Project Phase One--Feasibility Study Final Study Report November 2006 A subsidiary of Pinnacle West Capital Corporation Executive Summary On October 21, 2005 Arizona Public Service Company

More information

New Mexico Transmission Expansion Concepts For Wind Resources

New Mexico Transmission Expansion Concepts For Wind Resources New Mexico Transmission Expansion Concepts For Wind Resources May 2008 Update Electric Services Transmission Operations FOREWORD This document contains PNM s latest concepts for expanding the transmission

More information

PID 274 Feasibility Study Report 13.7 MW Distribution Inter-Connection Buras Substation

PID 274 Feasibility Study Report 13.7 MW Distribution Inter-Connection Buras Substation PID 274 Feasibility Study Report 13.7 MW Distribution Inter-Connection Buras Substation Prepared by: Entergy Services, Inc. T & D Planning L-ENT-17A 639 Loyola Avenue New Orleans, LA 70113 Rev Issue Date

More information

PUBLIC SERVICE COMPANY OF COLORADO SENATE BILL DESIGNATION OF ENERGY RESOURCE ZONES AND TRANSMISSION PLANNING REPORT PROCEEDING NO.

PUBLIC SERVICE COMPANY OF COLORADO SENATE BILL DESIGNATION OF ENERGY RESOURCE ZONES AND TRANSMISSION PLANNING REPORT PROCEEDING NO. PUBLIC SERVICE COMPANY OF COLORADO SENATE BILL 07-100 DESIGNATION OF ENERGY RESOURCE ZONES AND TRANSMISSION PLANNING REPORT PROCEEDING NO. 15M- E October 30, 2015 TABLE OF CONTENTS Section Page I. INTRODUCTION...

More information

WestConnect TTC/ATC Workshop. Joint CCPG-SSPG-SWAT Meeting NOVEMBER 16, 2017

WestConnect TTC/ATC Workshop. Joint CCPG-SSPG-SWAT Meeting NOVEMBER 16, 2017 WestConnect /ATC Workshop Joint CCPG-SSPG-SWAT Meeting NOVEMBER 16, 2017 WestConnect /ATC Workshop WestConnect /ATC Workshop Participants CCPG SSPG SWAT BEPC* NVE APS PRPA* SMUD EPE TRI-STATE TANC LADWP

More information

Emera Maine Representative: Jeffrey Fenn, P.E., SGC Engineering LLC

Emera Maine Representative: Jeffrey Fenn, P.E., SGC Engineering LLC OCTOBER 22, 2015 Emera Maine s Local System Plan Bangor Hydro District Needs Assessment/Potential Solutions Local Planning Advisory Committee Meeting Emera Maine Representative: Jeffrey Fenn, P.E., SGC

More information

Updated Transmission Expansion Plan for the Puget Sound Area to Support Winter South-to-North Transfers

Updated Transmission Expansion Plan for the Puget Sound Area to Support Winter South-to-North Transfers Updated Transmission Expansion Plan for the Puget Sound Area to Support Winter South-to-North Transfers Puget Sound Area Study Team Bonneville Power Administration, Puget Sound Energy, Seattle City Light,

More information

FINAL FACILITY STUDY. 230/69/13.8 kv Transformer Addition(s) at Badwater Substation 2009 T1. September 10, 2010

FINAL FACILITY STUDY. 230/69/13.8 kv Transformer Addition(s) at Badwater Substation 2009 T1. September 10, 2010 FINAL FACILITY STUDY 230/69/13.8 kv Transformer Addition(s) at Badwater Substation 2009 T1 September 10, 2010 I. Introduction This is a revised facility study performed for Transmission Queue Request 2009

More information

GENERAL DIRECTION SOUGHT AND SPECIFIC QUESTIONS TO BE ANSWERED

GENERAL DIRECTION SOUGHT AND SPECIFIC QUESTIONS TO BE ANSWERED DATE: June 28, 2011 STAFF: Brian Janonis Brian Moeck, PRPA Pre-taped staff presentation: none WORK SESSION ITEM FORT COLLINS CITY COUNCIL SUBJECT FOR DISCUSSION Electric Transmission Update. EXECUTIVE

More information

Emera Maine Representative: Jeffrey Fenn, P.E., SGC Engineering LLC

Emera Maine Representative: Jeffrey Fenn, P.E., SGC Engineering LLC OCTOBER 22, 2014 Emera Maine s Local System Plan Bangor Hydro District Needs Assessment/Potential Solutions Local Planning Advisory Committee Meeting E M i R t ti Emera Maine Representative: Jeffrey Fenn,

More information

CUSTOMER/ TWIN ARROWS PROJECT

CUSTOMER/ TWIN ARROWS PROJECT A subsidiary of Pinnacle West Capital Corporation CUSTOMER/ TWIN ARROWS PROJECT V1 Facility Study Report APS Contract 52149 Prepared by: Arizona Public Service Company Transmission & Distribution Asset

More information

EL PASO ELECTRIC COMPANY (EPE) FACILITIES STUDY FOR PROPOSED HVDC TERMINAL INTERCONNECTION AT NEW ARTESIA 345 KV BUS

EL PASO ELECTRIC COMPANY (EPE) FACILITIES STUDY FOR PROPOSED HVDC TERMINAL INTERCONNECTION AT NEW ARTESIA 345 KV BUS EL PASO ELECTRIC COMPANY (EPE) FACILITIES STUDY FOR PROPOSED HVDC TERMINAL INTERCONNECTION AT NEW ARTESIA 345 KV BUS El Paso Electric Company System Operations Department System Planning Section May 2004

More information

Supplement to ISO Transmission Plan. Harry Allen-Eldorado Project Description and Functional Specifications

Supplement to ISO Transmission Plan. Harry Allen-Eldorado Project Description and Functional Specifications Supplement to 2013-2014 ISO Transmission Plan Harry Allen-Eldorado Project Description and Functional Specifications Description and Functional Specifications of Proposed Economically Driven Harry Allen

More information

TOLTEC POWER PARTNERSHIP TOLTEC POWER PROJECT INTERCONNECTION STUDY SYSTEM IMPACT STUDY

TOLTEC POWER PARTNERSHIP TOLTEC POWER PROJECT INTERCONNECTION STUDY SYSTEM IMPACT STUDY TOLTEC POWER PARTNERSHIP TOLTEC POWER PROJECT INTERCONNECTION STUDY SYSTEM IMPACT STUDY January 7, 2002 Prepared by Jorge Chacon (Consultant) Tucson Electric Power Company Ed Beck ii EXECUTIVE SUMMARY

More information

Interconnection Feasibility Study Report Request # GI

Interconnection Feasibility Study Report Request # GI A. Executive Summary Interconnection Feasibility Study Report Request # GI-2011-04 587 MW Combined Cycle 2x1 Generators Cherokee Station, Denver, Colorado Public Service Company of Colorado Transmission

More information

Customer Charge or Minimum Bill. Total Average Annual Bill (9 Dth) Total Volumetric Rate*

Customer Charge or Minimum Bill. Total Average Annual Bill (9 Dth) Total Volumetric Rate* Residential Gas Rates for Wyoming Regulated Utilities Gas Rates are in effect as of: 11/03/17 Estimates of Seasonal Bills (illustrational purposes only) Customer Charge or Minimum Bill Total Volumetric

More information

15 Nelson-Marlborough Regional Plan

15 Nelson-Marlborough Regional Plan 15 Nelson-Marlborough Regional Plan 15.1 Regional overview 15.2 Nelson-Marlborough transmission system 15.3 Nelson-Marlborough demand 15.4 Nelson-Marlborough generation 15.5 Nelson-Marlborough significant

More information

SPP OVERVIEW. Mike Ross Senior Vice President, Government Affairs and Public Relations

SPP OVERVIEW. Mike Ross Senior Vice President, Government Affairs and Public Relations SPP OVERVIEW Mike Ross Senior Vice President, Government Affairs and Public Relations 1 Our Mission Helping our members work together to keep the lights on today and in the future. 2 NORTH AMERICAN INDEPENDENT

More information

WIRES University Overview of ISO/RTOs. Mike Ross Senior Vice President Government Affairs and Public Relations Southwest Power Pool

WIRES University Overview of ISO/RTOs. Mike Ross Senior Vice President Government Affairs and Public Relations Southwest Power Pool WIRES University Overview of ISO/RTOs Mike Ross Senior Vice President Government Affairs and Public Relations Southwest Power Pool 1 OUR MISSION Helping our members work together to keep the lights on

More information

Local Transmission Plan. October 11, 2013 Revised August 25, 2014

Local Transmission Plan. October 11, 2013 Revised August 25, 2014 Local Transmission Plan October 11, 2013 Revised August 25, 2014 2 Central Hudson s System Zone G: Majority of Central Hudson s load Zone E: One small distribution substation Interconnections with Consolidated

More information

Local Transmission Plan

Local Transmission Plan 2012 2013 Local Transmission Plan Idaho Power Delivery Planning Final Report December 2013 2013 Idaho Power Idaho Power Company TABLE OF CONTENTS Table of Contents... i List of Tables... ii List of Figures...

More information

MILLIGAN SOLAR PROJECT

MILLIGAN SOLAR PROJECT February 16, 2009 Page 1 of 18 A subsidiary of Pinnacle West Capital Corporation MILLIGAN SOLAR PROJECT FINAL Feasibility Study Report APS Contract 52115 Prepared by: Arizona Public Service Company Transmission

More information

Four Corners Queue Transmission Interconnection Study

Four Corners Queue Transmission Interconnection Study Four Corners Queue Transmission Interconnection Study Facility Study Results By Arizona Public Service Company Transmission Planning & Interconnection Development March 22, 2016 Version 1 FACILITIES STUDY

More information

South Dakota 890 Study

South Dakota 890 Study South Dakota 890 Study September 16, 2011 South Dakota 890 Study Presentation of 890 Study results from 2011 Includes WAPA suggested system improvements and timelines Stakeholder Feedback Questions? 2

More information

Western Area Power Administration Sierra Nevada Region

Western Area Power Administration Sierra Nevada Region Western Area Power Administration Sierra Nevada Region 2014 Annual Ten-Year Transmission Plan Assessment Report November 20, 2014 For information or questions regarding this Transmission Assessment Report,

More information

Transmission Planning using Production Cost Simulation & Power Flow Analysis

Transmission Planning using Production Cost Simulation & Power Flow Analysis ABB Transmission Planning using Production Cost Simulation & Power Flow Analysis Jinxiang Zhu, Ph.D. Senior Principal, ABB Power Consulting ABB Group January 16, 2018 Slide 1 Power System Studies TECHNICAL

More information

Interconnection Feasibility Study Report GIP-226-FEAS-R3

Interconnection Feasibility Study Report GIP-226-FEAS-R3 Interconnection Feasibility Study Report GIP-226-FEAS-R3 System Interconnection Request #226 70 MW Wind Generating Facility Kings County (L-6013) 2010 07 21 Control Centre Operations Nova Scotia Power

More information

Verde Transmission, LLC. Verde Project. System Impact Study Report

Verde Transmission, LLC. Verde Project. System Impact Study Report Verde Transmission, LLC Verde Project System Impact Study Report March 2017 Prepared by: Public Service Company of New Mexico Foreword This report was prepared for Verde Transmission, LLC by the PNM Transmission/

More information

Reliability Must-Run Analysis th BTA Presentation. Bob Smith Manager Transmission Planning June 6, 2006

Reliability Must-Run Analysis th BTA Presentation. Bob Smith Manager Transmission Planning June 6, 2006 Reliability Must-Run Analysis 2006 2015 4 th BTA Presentation Bob Smith Manager Transmission Planning June 6, 2006 Outline of Presentation 2006 RMR Study Process Description of network and constraint SIL/MLSC

More information

City of Palo Alto (ID # 6416) City Council Staff Report

City of Palo Alto (ID # 6416) City Council Staff Report City of Palo Alto (ID # 6416) City Council Staff Report Report Type: Informational Report Meeting Date: 1/25/2016 Summary Title: Update on Second Transmission Line Title: Update on Progress Towards Building

More information

Western NY Public Policy Transmission Planning Report

Western NY Public Policy Transmission Planning Report Western NY Public Policy Transmission Planning Report Dawei Fan Supervisor, Public Policy and Interregional Planning Business Issues Committee September 12, 2017 Operating Committee September 15, 2017

More information

Pacific Gas and Electric Company s Revised 2016 Annual Progress

Pacific Gas and Electric Company s Revised 2016 Annual Progress March 06, 2016 Mr. Philip Augustin Chair, WECC Technical Studies Subcommittee Mr. Enoch Davies WECC Technical Staff 155 North 400 West Salt Lake City, UT 84103-1114 Subject: Report Pacific Gas and Electric

More information

OCTOBER 17, Emera Maine Representative: Jeffrey Fenn, P.E., LR/SGC Engineering LLC

OCTOBER 17, Emera Maine Representative: Jeffrey Fenn, P.E., LR/SGC Engineering LLC OCTOBER 17, 2018 Emera Maine s Local System Plan Bangor Hydro District Needs Assessment/Potential Solutions Local Planning Advisory Committee Meeting Emera Maine Representative: Jeffrey Fenn, P.E., LR/SGC

More information

Burlington Lamar 345/230 kv Impact and 2013 Post TPL Assessment Study

Burlington Lamar 345/230 kv Impact and 2013 Post TPL Assessment Study Burlington Lamar 345/230 kv Impact and 2013 Post TPL Assessment Study Vince Leung May 1, 2014 Reviewed by: Chris Pink (edited July 8, 2014) Table of Contents Page Background... 4 Objectives... 5 Study

More information

Outer Metro 115 kv Transmission Development Study. (Scott Co, Carver Co and Hennepin Co)

Outer Metro 115 kv Transmission Development Study. (Scott Co, Carver Co and Hennepin Co) Outer Metro 115 kv Transmission Development Study. (Scott Co, Carver Co and Hennepin Co) Participants: Great River Energy Xcel Energy Inc. Executive Summary This study is done to address various load serving

More information

15 Nelson-Marlborough Regional Plan

15 Nelson-Marlborough Regional Plan 15 Nelson-Marlborough Regional Plan 15.1 Regional overview 15.2 Nelson-Marlborough transmission system 15.3 Nelson-Marlborough demand 15.4 Nelson-Marlborough generation 15.5 Nelson-Marlborough significant

More information

Sub Regional RTEP Committee Western Region ATSI

Sub Regional RTEP Committee Western Region ATSI Sub Regional RTEP Committee Western Region ATSI February 20, 2019 1 ATSI Needs Stakeholders must submit any comments within 10 days of this meeting in order to provide time necessary to consider these

More information

SunZia Southwest Transmission Project

SunZia Southwest Transmission Project SunZia Southwest Transmission Project SunZia Project Update for the Southern Arizona Economic Development Group September 12, 2017 SUNZIA SOUTHWEST TRANSMISSION PROJECT SEPTEMBER 12, 2017 0 SouthWestern

More information

Alberta Electric System Operator Saleski Transmission Project Needs Identification Document

Alberta Electric System Operator Saleski Transmission Project Needs Identification Document Decision 2013-127 Alberta Electric System Operator Saleski Transmission Project Needs Identification Document ATCO Electric Ltd. Saleski 901S Substation and 144-kV Transmission Line 7L142 Facility Application

More information

PJM Generator Interconnection Request Queue #R60 Robison Park-Convoy 345kV Impact Study September 2008

PJM Generator Interconnection Request Queue #R60 Robison Park-Convoy 345kV Impact Study September 2008 PJM enerator Interconnection Request Queue #R60 Robison Park-Convoy 345kV Impact Study 504744 September 2008 PJM Interconnection 2008. All rights reserved R60 Robison Park-Convoy 345kV Impact Study eneral

More information

Interconnection Feasibility Study Report GIP-222-FEAS-R3

Interconnection Feasibility Study Report GIP-222-FEAS-R3 Interconnection Feasibility Study Report GIP-222-FEAS-R3 System Interconnection Request #222 48 MW Steam Generating Facility Pictou County (53N) 2010 07 30 Control Centre Operations Nova Scotia Power Inc.

More information

Midway/Monument Area TTC Study

Midway/Monument Area TTC Study Midway/Monument Area TTC Study (includes the following lines: Midway Geesen 115 kv, Geesen Falcon 115 kv, Falcon Fuller 115 kv, Fuller Black Squirrel 115 kv, and Black Squirrel Monument 115 kv) Johnny

More information