Circuit-Breakers Bulletin 140 / KTA 3

Size: px
Start display at page:

Download "Circuit-Breakers Bulletin 140 / KTA 3"

Transcription

1 Motor Protection Characteristics High Switching Capacity High Current Limiting For Compact Motor Starters Overview... - Product Selection -Pole Pole Accessories Type: Bulletin 40-MN / KTA -5 Bulletin 40-CMN / KTA - Bulletin 40M-K5F / KTA -S Bulletin 40M-M5F / KTA -S Bulletin 40M-P5F / KTA -S Current Range: A A A 5... A A Performance...- General Standards and Approvals...-9 Weight Accessories Coordination Tables... - Ordering Advice: For Allen-Bradley branded products choose the Allen-Bradley Cat. No. For Sprecher+Schuh branded products choose the Sprecher+Schuh Ref. or Art. No. imensions... -7

2 Overview Bulletin 40-MN / KTA -5 Compact bus-bar Supply block Blank space cover Auxiliary contact block for flush mounting Current limiter Supply block Auxiliary contact block for left side mounting Circuit-breaker 40-MN / KTA -5 Undervoltage trip for right side mounting Trip contact block Shunt trip for right side mounting Modular design for simple configuration Modular accessories enable the circuit-breakers to be fitted with auxiliary contacts, trip indicating auxiliary contacts and undervoltage or shunt trips simply and quickly to suit the specific application. High switching capacity reduces plant downtime Effective current limitation and low let-through energy (of the downstream contactor) enable normal operation to be resumed quickly after a short-circuit. Integrated automation systems The comprehensive range of accessories such as auxiliary contacts, trip indicating auxiliary contacts, undervoltage and shunt trips enable the circuit-breakers to be fully integrated in automatic control systems. Fast fault-finding Fault-finding and commissioning are made easy as information on switch and tripping statuses are signalled remotely and indicated locally. -

3 Overview Bulltin 40-CMN / KTA - Trip contact block Circuit-breaker with lockable rotary handle 40-CMN / KTA - Undervoltage trip Shunt trip Circuit-breaker 40-CMN / KTA - Auxiliary contact block Modular design for simple configuration Modular accessories enable the circuit-breakers to be fitted with auxiliary contacts, trip indicating auxiliary contacts and undervoltage or shunt trips simply and quickly to suit the specific application. High switching capacity reduces plant downtime Effective current limitation and low let-through energy (of the downstream contactor) enable normal operation to be resumed quickly after a short-circuit. Integrated automation systems The comprehensive range of accessories such as auxiliary contacts, trip indicating auxiliary contacts, undervoltage and shunt trips enable the circuit-breakers to be fully integrated in automatic control systems. Fast fault-finding thanks to display of the right information Fault-finding and commissioning are made easy because information on switch and tripping statuses and the cause of tripping is signalled remotely by an auxiliary contact block and indicated locally. Use as main or EMERGENCY OFF switch The circuit-breakers type 40-CMN / KTA - comply with isolation requirements and can be used as main or EMERGENCY OFF switches. -

4 Overview Bulletin 40M-K5F...40M-P5F / KTA -S...KTA -S Circuit-breaker 40M-K5F / KTA -S Circuit-breaker 40M-M5F / KTA -S Circuit-breaker 40M-P5F / KTA -S Toggle switch locking arrangement oor coupling assembly -4

5 Overview Bulletin 40M-K5F...40M-P5F / KTA -S...KTA -S Auxiliary contact block Undervoltage trip Trip contact block Shunt trip Circuit-breaker 40M-K5F / KTA -S Auxiliary contact block and Trip contact block Auxiliary contact block Undervoltage trip Trip contact block Shunt trip Auxiliary contact block and Trip contact block Circuit-breaker 40M-P5F / KTA -S High switching capacity reduces plant downtime Effective current limitation and low let-through energy (of the downstream contactor) enable normal operation to be resumed quickly after a short-circuit. Integrated automation systems The comprehensive range of accessories such as auxiliary contacts, trip indicating auxiliary contacts, undervoltage and shunt trips enable the circuit-breakers to be fully integrated in automatic control systems. Use as main or EMERGENCY OFF switch The circuit-breakers type 40-CMN / KTA - comply with isolation requirements and can be used as main or EMERGENCY OFF switches. A locking device and a door coupling are available -5

6 Product Selection -Pole 40-MN / KTA CMN / KTA - 40M-P5F / KTA -S Thermal release Magentic release Adjustment range Operating current 0 V V 90 V 0 V 40 V 575 V MN-00 KTA -5-0.A MN-005 KTA A / MN-0040 KTA A / / MN-00 KTA -5-0.A /0. 0.8/ /0.55 / 40-MN-0 KTA -5-A / / /. / / 4 40-MN-0 KTA -5-.A / / -/ 40-MN-0 KTA -5-.5A /0.75./.5./.0 40-MN-0 KTA A /.5./.5.7/4.0 -/ 5 40-MN-00 KTA -5-.A /.0.0/ / / 0 40-MN-0 KTA -5-A / /7.5 / MN-0 KTA -5-A / 5/ MN-000 KTA -5-0A /7.5 /.5 8.5/ 7-/ MN-0 KTA -5-5A / /.5 5/ CMN-0 KTA --5A / 5/ 5/ CMN-0 KTA --40A /0 5/.5 7/ CMN-00 KTA --A...90 /5 7/45 / CMN-9000 KTA --90A M-K5F-C KTA -S-A M-K5F-C KTA -S-A /45 40M-K5F-C80 KTA -S-80A 0 Switching of phase AC motors, AC-, AC- Icu -phase [kw] ( Hz) /45 V -phase [HP] (0 Hz) Ics Allen-Bradley Cat. No. Sprecher+Schuh Type Ref. Index /55 40M-K5F- KTA -S-A M-K5F- KTA -S-5A /90 40M-K5F- KTA -S-A /90 40M-M5F- KTA -S-A M-M5F-0 KTA -S-00A / 40M-M5F-5 KTA -S-A / 40M-P5F-5 KTA -S-A /85 40M-P5F- KTA -S-0A /0 40M-P5F-40 KTA -S-A 9 Ics Rated service short-circuit breaking capacity Icu Ultimate short-circuit breaking capacity Utilization categories and conditions for testing for alternating current per IEC 947: AC- AC- starting and reversing of slip ring motors starting and disconnecting squirrel cage induction motors IEC 947- performance categories: Icu still operational after testing with O-t-CO Ics suitable for normal operation after testing with O-t-CO-t-CO O = CO = t = off restart and off set delay Accessories Page -8 Page - imensions Page -7 -

7 Product Selection 4-Pole 40M-K5F4 / KTA -S4 Thermal release Magentic release 40M-P5F4 / KTA -S4 Switching of phase AC motors, AC-, AC- Icu -phase [kw] ( Hz) /45 V -phase [HP] (0 Hz) Ics Allen-Bradley Cat. No. Sprecher+Schuh Type Ref.. Index 40M-K5F4-C KTA -S4-A 0 40M-K5F4-C KTA -S4-A 40M-K5F4-C80 KTA -S4-80A Adjustment range Operating current 0 V V 90 V 0 V 40 V 575 V / /55 40M-K5F4- KTA -S4-A M-K5F4- KTA -S4-5A /90 40M-K5F4- KTA -S4-A /90 40M-M5F4- KTA -S4-A M-M5F4-0 KTA -S4-00A / 40M-M5F4-5 KTA -S4-A / 40M-P5F4-5 KTA -S4-A /85 40M-P5F4- KTA -S4-0A /0 40M-P5F4-40 KTA -S4-A 4 Ics Rated service short-circuit breaking capacity Icu Ultimate short-circuit breaking capacity Utilization categories and conditions for testing for alternating current per IEC 947: AC- AC- starting and reversing of slip ring motors starting and disconnecting squirrel cage induction motors IEC 947- performance categories: Icu still operational after testing with O-t-CO Ics suitable for normal operation after testing with O-t-CO-t-CO O = CO = t = off restart and off set delay Accessories Page -8 Page - imensions Page -7-7

8 Accessories Accessories for Circuit-Breaker 40-MN / KTA -5 escription 40-MN A KTA MN A KTA -5 Undervoltage trip for right side mounting KJ 4 V, Hz / 8 V, 0 Hz V, Hz / 7 V, 0 Hz A V, Hz / V, 0 Hz T 40 V, Hz / 77 V, 0 Hz N V, Hz / V, 0 Hz B 45 V, Hz / 480 V, 0 Hz Shunt trip for right side mounting KJ 4 V, Hz / 8 V, 0 Hz V, Hz / 7 V, 0 Hz A V, Hz / V, 0 Hz T 40 V, Hz / 77 V, 0 Hz N V, Hz / V, 0 Hz B 45 V, Hz / 480 V, 0 Hz 40-A KT -5-PE A0 KT -5-PE A0 KT -5-PE AL KT -5-PE-L 4 A 40-A0 KT -5-PA-0 47 PA-0 PA- 40-A0 KT -5-PA A KT -5-PA T KT -5-PF- 40-T0 KT -5-PF UV-KJ KT -5-UA4V/8V UV- KT -5-UAV/7V UV-A KT -5-UA0-0V/40-0V UV-T KT -5-UA40V/77V UV-N KT -5-UA80-V/440-40V UV-B KT -5-UA45V/480V RT-KJ KT -5-AA4V/8V RT- KT -5-AAV/7V RT-A KT -5-AA0-0V/40-0V RT-T KT -5-AA40V/77V0 40-RT-N KT -5-AA80-V/440-40V0 40-RT-B KT -5-AA45V/480V0 T0 PF-0 KT RT.. KTA UA-...V MN KT -5-PE- PE-0 PE-L A0 KT UV.. KTA A PF- 40-MN Index KT T Trip contact blocks Indicate tripping of circuit-breaker AL Sprecher+Schuh Type Ref PA-0 40-MN A0 PE- PE-0 A0 KTA -5 A0 KT PE- Auxiliary contact blocks -pole Auxiliary contact blocks for left side mounting -pole Use compact bus-bars with 54 mm spacing Allen-Bradley Cat. No. Connection diagram KT AA-...V.. Product Selection Page - -8

9 Accessories Accessories for Circuit-Breaker 40-CMN / KTA - escription Allen-Bradley Cat. No. Connection diagram 40-CMN KTA - KT CA0 PE-0 CA0 CA PE-0 PE- Auxiliary contact blocks 40-CMN KTA - CT0-0 CT0- CT-0 40-CA0 KT --PE CA0 KT --PE-0 40-CA KT --PE- 40-CT- KT --PF-0 7 PF-0 PF- PF- 40-CT0-0 KT --PF CT0- KT --PF CT-0 KT --PF CUV-KJ KT --UA-4V 7 40-CUV- KT --UA-V 7 40-CUV-A KT --UA 0V 7 40-CRT-KJ KT --AA-4V CRT- KT --AA-V CRT-A KT --AA0V 7 KT PF-0 Trip contact blocks ifferential indication: Overload / short-circuit release a) b) 40-CMN Overload release Short-circuit release CUV.. KTA - KT UA-...V.. KJ 4 V, Hz / 8 V, 0 Hz V, Hz / 7 V, 0 Hz A V, Hz / V, 0 Hz b) 40CMN Short-circuit release CRT.. Shunt trip Integrated short-circuit trip contact Index CT- Undervoltage trip Integrated short-circuit trip contact Sprecher+Schuh Type Ref. KTA - KT AA-...V.. KJ 4 V, Hz / 8 V, 0 Hz V, Hz / 7 V, 0 Hz A V, Hz / V, 0 Hz b) Short-circuit release Product Selection Page - -9

10 Accessories Accessories for Circuit-Breaker 40M-K5F / KTA -S escription Connection diagram 40M-K5F 40M-K5F Index EA KT PE-W Auxiliary switch blocks Leads labelled and fitted with terminal sleeves Sprecher+Schuh Type Ref. 40M-K-... EA KTA -S Allen-Bradley Cat. No. 40M-K-EA KT --PE-W 77 40M-K-EA KT --PE-W 78 40M-K-ER KT --PF 79 40M-K-EAR KT --PE-PF 80 40M-K-UKJ KT --UA4V/0 8 40M-K-UK KT --UA-7V/0 8 40M-K-UKF KT --UA08-40V/0 8 40M-K-UKN KT --UA80-480V/ M-K-UZJ KT --UA4VC 85 40M-K-UZ KT --UA-7VC 8 40M-K-UZA KT --UA0-VC 87 40M-K-AKJ KT --AA4V/ M-K-AK KT --AA-7V/ M-K-AKF KT --AA08-40V/ M-K-AKN KT --AA80-480V/0 9 40M-K-AZJ KT --AA4VC 9 40M-K-AZ KT --AA-7VC 9 40M-K-AZA KT --AA0-VC 94 PE-W 40M-K-... ER KTA -S Trip contact blocks Leads labelled and fitted with terminal sleeves KT PF 40M-K5F 40M-K-... EAR KTA -S Undervoltage trip Leads labelled and fitted with terminal sleeves KJ K KF KN KT PE-PF Auxiliary- and trip contact blocks Leads labelled and fitted with terminal sleeves 40M-K5F 40M-K-... U.. KTA -S KT UA-...V.. 4 V, /0 Hz...7 V, /0 Hz V, /0 Hz V, /0 Hz ZJ 4 VC Z...7 VC ZA 0... VC Shunt trip Leads labelled and fitted with terminal sleeves KJ K KF KN 4 V, /0 Hz...7 V, /0 Hz V, /0 Hz V, /0 Hz ZJ 4 VC Z...7 VC ZA 0... VC 40M-K5F 40M-K-... A.. KTA -S KT AA-...V.. Product Selection Page - -

11 Accessories Accessories for Circuit-Breaker 40M-M5F + 40M-P5F / KTA -S + KTA -S escription Connection diagram 40M-M5F Auxiliary switch blocks Leads labelled and fitted with terminal sleeves Trip contact blocks Leads labelled and fitted with terminal sleeves EA KTA -S KT KTA -S PE-W Auxiliary contact- and trip contact blocks Leads labelled and fitted with terminal sleeves Undervoltage trip Leads labelled and fitted with terminal sleeves KJ K KF KN 4 V, /0 Hz...7 V, /0 Hz V, /0 Hz V, /0 Hz ER KTA -S KT KTA -S PF K KJ KF KN...7 V, /0 Hz 4 V, /0 Hz V, /0 Hz V, /0 Hz ZJ 4 VC Z...7 VC ZA 0... VC EA 40M-P-EA KT --PE-W 95 40M-P-EA KT --PE-W 9 40M-P-ER KT --PF 97 40M-P-EAR KT --PE-PF 98 40M-P-UKJ KT --UA4V/ M-P-UK KT --UA-7V/0 40M-P-UKF KT --UA08-40V/0 40M-P-UKN KT --UA80-480V/0 40M-P-UZJ KT --UA4VC 40M-P-UZ KT --UA-7VC 4 40M-P-UZA KT --UA0-VC 5 40M-P-AKJ KT --AA4V/0 40M-P-AK KT --AA-7V/0 7 40M-P-AKF KT --AA08-40V/0 8 40M-P-AKN KT --AA80-480V/0 9 40M-P-AZJ KT --AA4VC 40M-P-AZ KT --AA-7VC 40M-P-AZA KT --AA0-VC PE-W 40M-P M-P5F EAR KTA -S KT KTA -S PE-PF 40M-M5F 40M-P M-P5F U.. KTA -S KT KTA -S UA-...V.. ZJ 4 VC Z...7 VC ZA 0... VC Shunt trip Leads labelled and fitted with terminal sleeves Index 40M-P M-P5F 40M-M5F Sprecher+Schuh Type Ref. 40M-P M-P5F 40M-M5F Allen-Bradley Cat. No. 40M-M5F 40M-P M-P5F A.. KTA -S KT KTA -S AA-...V.. Product Selection Page - -

12 Accessories Accessories for Circuit-Breaker 40-MN / KTA -5 Allen-Bradley Cat. No. escription Current limiter Increased switching capacity No back-up fuse required Safe operation Repulsion contacts close automatically Can be used as single and group protection Can be mounted next to 40-MN / KTA -5 with compact bus-bars or snap mounted on 40-MN / KTA -5 Current limiter also acts as a terminal block Sprecher+Schuh Type Ref. Index 40-CL KTL --N 40-L KT -5-A 4 40-L KT -5-A 5 x connections 40-L45 KT -5-B-45- x connections 40-L45 KT -5-B x connections 40-L454 KT -5-B x connections 40-L455 KT -5-B x connections 40-L KT -5-B-54- x connections 40-L KT -5-B-54-4x connections 40-L KT -5-B x connections 40-L KT -5-B L KT -5-BA 4 Supply blocks For the supply of compact bus-bars Increases terminal capacity Compact bus-bars 45 mm spacing for circuit breakers with flush-mounted auxliary contact block 54 Compact bus-bars 54 mm spacing for circuit breakers with side-mounted auxiliary switch blocks Blank space cover For covering unused connection lugs Product Selection Page - -

13 Accessories Accessories for Circuit-Breaker 40-MN / KTA -5 Allen-Bradley Cat. No. escription Enclosure With knock-outs for signal lights, including earth protection and neutral wire terminals 40-E4 / KT -5-KA 40-E55 / KT -5-KAZ Sprecher+Schuh Type Ref. Index Protection class: IP4 40-E4 KT -5-KA 5 Protection class: IP55 (with seal and protective membrane) 40-E55 KT -5-KAZ 40-N8 KT -5-M 7 Button membrane Spare part with 4 grooved screws (not including mounting frame) red V 40-LR KT -5-L-RT-V 8 red 40 V 40-LR40 KT -5-L-RT-40V 9 red V 40-LR KT -5-L-RT-V green V 40-LG KT -5-L-GN-V green 40 V 40-LG40 KT -5-L-GN-40V green V 40-LG KT -5-L-GN-V white V 40-LW KT -5-L-WS-V 4 white 40 V 40-LW40 KT -5-L-WS-40V 5 white V 40-LW KT -5-L-WS-V Locking arrangement Mounting on the enclosure For... padlocks mm in diameter 40-N KT -5-S 7 Locking arrangement For locking the START button For... padlocks mm in diameter 40-N4 KT -5-SC 8 Screw adapter For screw arrangement of a circuit breaker 40-N KT -5-AS 9 Indicator light For mounting in upper part of enclosure with plug-in connector Connection cable 80 mm long, including lamp Accessories for Circuit-Breaker 40-CMN / KTA - Allen-Bradley Cat. No. escription Lockable rotary handle For... padlocks mm in diameter Can be locked in OFF position Sprecher+Schuh Type Ref. Index black hanle 40-KN KT --KN 40 red handle with yellow self-adhesive label 40-KRY KT --KRY 4 Product Selection Page - -

14 Accessories Accessories for Circuit-Breaker 40M-K5F... 40M-P5F / KTA -S... KTA -S escription For use with Allen-Bradley Cat. No. Sprecher+Schuh Type Ref. Index red / black knob 40M-K5F / KTA -S 40M-K-54N KT --HRB 4 red / black knob 40M-M5F + 40M-P5F / KTA -S + KTA -S 40M-P-54N KT --HRB 4 all 40M-P-S KT --HTA 44 40M-K5F / KTA -S 40M-K-M KT --SA 45 40M-M5F + 40M-P5F / KTA -S + KTA -S 40M-P-M KT --SA 4 40M-K-KN KT --HN 47 40M-K-KE KT --HRY 48 40M-P-KN KT --HN 49 40M-P-KE KT --HRY 40M-K5F / KTA -S 40M-K-PF KT --FA 5 40M-M5F / KTA -S 40M-M-PF KT --FA 5 40M-P5F / KTA -S 40M-P-PF KT --FA 5 all 40M-P-Q KT --FA-S 54 40M-K5F / KTA -S 40M-K-C KT --HA 55 40M-M5F / KTA -S 40M-M-C KT --HA 5 40M-P5F / KTA -S 40M-P-C KT --HA 57 Complete door coupling assemble Comprising: knob, coupling, shaft and actuator For three 4 mm diam. padlocks Locks inserted in position 0 Shaft 0 mm Protection Class: IP54 Replacement shaft for complete door coupling assemble only L = 0 mm (not compatible with the previous type KT --HT) Toggle switch locking attachment For locking the circuit-breaker in the OFF position black knob Lockable knob For three...8 mm diam. padlocks Protection Class: IP40 red knob black knob red knob Remote operator For remote pushbutton ON / OFF control of circuit-breaker Automatic OFF by integrated position Us = 0 V switch Mechanical position indicator (ON / OFF / TRIPPE ) Locking device for remote operator Cylinder lock Kit for installation on site Prevents electrical operation Mechanically interlocked shutter prevents manual operation Prevents removal of mechanism cover Terminal covers Provides finger protection 40M-K5F / KTA -S 40M-M5F + 40M-P5F / KTA -S + KTA -S Product Selection Page - -4

15 Notes -5

16 IEC Performance ata 40-MN-... (KTA ) (0.A) (0.5A) 0040 (0.4A) 00 (0.A) 0 (A) 0 (.A) 0 (.5A) 0 (4A) 00 (.A) 0 (A) 0 (A) 000 (0A) 0 (5A) Switching of standard three-phase motors AC-, AC- 0/40 V [kw] 0.0/ /0. 0.8/ /0.75./.5.5/.0.7/ /7.5 /45 V [kw] / /0. 0.8/ / /0.75./.5./.5.0/ / / /.5 0 V [kw] / /..5/.0.7/. 7.5/.5/ 90 V [kw] / /..5./.0.7/ /7.5 /.5 5/ 8.5/ Back-up fuses gg, am, only if Icc > Icu 0/40 V /45 V V 90 V /40 V /45 V V 0 90 V Ultimate short-circuit breaking capacity Icu Rated service short-circuit breaking capacity Ics 0/40 V 0 /45 V 0 V V 4.5 Performance ata per UL, CSA as a Starter (UL 8, CSA C. No..4, in connection with a short-circuit protection device) 40-MN-... (KTA ) (0.A) (0.5A) 0040 (0.4A) 00 (0.A) 0 (A) 0 (.A) 0 (.5A) 0 (4A) 00 (.A) 0 (A) 0 (A) 000 (0A) 0 (5A) Max. short-circuit current 480 V V Motor load, single-phase 5 V [HP] / /8 /4 / -/ 00 V [HP] 0 V [HP] / / / -/ Motor load, three-phase 00 V [HP] / /4 -/ V [HP] / -/ / 40 V [HP] / / V [HP] / -/ 5 7-/ 5 0 Maximum rated current of protection device 0 Product Selection Page - -

17 IEC Performance ata 40-CMN-... (KTA --...) 0 (5A) 40M-K5F (4)-... (KTA -S(4)-...) 40M-M5F(4)-... (KTA -S(4)-...) 0 (40A) 00 (A) 9000 (90A) C (A) C (A) C80 (80A) (A) (5A) (A) (A) 0 (00A) 40M-P5F(4)-... (KTA -S(4)-...) 5 (A) 5 (A) (0A) 40 (A) 5.5/7.5 /.5/0 /5.5/5 /0 /5 0/.5 7/40 45/ 45/ 55/ / 7.5/.5 5/ 5/.5 7/ /45 /55 75/90 75/90 / / /85 00/0 / 8.5/5 0/40 45/55 0/.5 7/40 45/ / 90/ / / 85/0 5/ 5/0 7/55 /75 7/45 55 /75 90 / / /85 00/0 00/0 /00 5/ Performance ata per UL, CSA as a Starter (UL 8, CSA C. No..4, in connection with a short-circuit protection device) 40-CMN-... (KTA --...) 0 (5A) 0 (40A) 00 (A) 9000 (90 A) / 5 7-/ -/ Product Selection Page - -7

18 General ata 40-MN (KTA -5) 40-CMN (KTA -) 40M-K5F (KTA -S) 40M-M5F (KTA -S) 40M-P5F (KTA -S) Rated insulation voltage IEC, SEV, VE V UL, CSA 00 V Rated frequency Hz Life span mechanical 000 oper oper oper. 000 oper oper. electrical 000 oper. 000 oper. up to A oper. up to 90 A 000 oper oper oper. max. 0 oper. /h. max. 0 oper. /h. max. 0 oper. /h. max. 0 oper. /h. max. 0 oper. /h. Switching frequency Ambient temperature storage - 5 C C - 0 C C operation - 5 C C - 5 C C Resistance to climatic change C IV (Coordination according to IEC 8) 40 C, 9 %, 5 days amp heat Alternating climatic conditions Protection class Resistance to shock IEC 8 T-: IP0 closed 0 G, 0 ms 40 C, 9 % IEC 8 T-: C, 8 %/40 C, 9 %, 5 cycles 5 C/55 C, 9 % IP00 / IP0 with terminal cover under test 5 G, 5 ms Resistance to vibration Frequency range In all directions... Hz... Hz >7.5 G under test G Rated thermal current Ith IEC, SEV, VE 00 at 40 C ambient temperature at 0 C ambient temperature Rated supply current Ie A 5... A A A A A A A setting ranges 4 setting ranges setting ranges setting ranges setting ranges A A A 5... A A setting ranges A: setting ranges A: setting ranges A: A A A A 5 A 80 A 0 C 40 A 0 A 0 A 70 C A A 40 A Temperature dependency 40 C C See temperature compensation Rated impulse withstand voltage Uimp/pollution degree Main circuits kv/ kv/ 8 kv/ 8 kv/ 8 kv/ Auxiliary circuits kv/ kv/ 4 kv/ 4 kv/ 4 kv/ Overload protection Characteristics motor protection - 0 C C Ambient temperature compensation Phase-failure protection - 5 C C differential release fixed setting x Iemax. fixed setting 4 x Iemax. value setting range Magnetic release Response current Iemax. = maximum values of setting ranges Total power loss Pv circuit-breaker at rated load operating temperature 7W W 45 W 75 W W Product Selection Page - -8

19 General ata 40-MN (KTA -5) Conformity to standards 40-CMN (KTA -) 40M-K5F (KTA -S) 40M-M5F (KTA -S) 40M-P5F (KTA -S) IEC 947-//4/5; IEC 947-//4/5; IEC947-//4/5; EN 0947; EN 0947 EN 0947 UL 8; CSA. Approvals CE, SEV, Germ. Lloyd, CE, UL, CSA, PTB, EMKO, SEMKO, (Germ. Lloyd, ETI, NEMKO, Bureau Veritas, UL, CSA, Lloyd s Reg. of Shipping, Bureau Veritas, Maritime Reg. of Shipping, RINA in preparation) Lloyd s Reg. of Shipping, Maritime Reg. of Shipping, RINA, CE, (Germ. Lloyd, Bureau Veritas, Lloyd s Reg. of Shipping, Maritime Reg. of Shipping, RINA in preparation) Terminal parts Type of terminals fine stranded [mm] x... 4 x max. 70 max. max. 85 coarse stranded [mm] x... x 4... max. 95 max. max. 40 Tightening torque [Nm] coarse stranded [AWG] No..... No..... No /0 MCM 00 MCM 0 Tightening torque [lb-in] Weights Three-pole circuit-breaker Four-pole circuit-breaker Accessories Auxiliary contact blocks on 40-MN (KTA -5) 40-A... (KT -5-PE...) Auxiliary contact blocks for left side mounting on 40-MN (KTA -5) 40-A... (KT -5-PA...) at 40 C ambient temperature A A at 0 C ambient temperature 4A A AC B 00 Standard Pilot uty B 00 Standard Pilot uty C R 00 Light Pilot uty R 00 Light Pilot uty Compatible with electronics, positively driven Rated thermal current Ith Contact class coordination according to NEMA (UL/CSA-Standards) Contacts Contact reliability acc. to IN 9 40 H-contact bridges Back-up fuses gl, gl A Rated supply current AC-5: C-: A 0/40 V A /45 V A 0 V 0.8 A 90 V 0.5 A 0/40 V A /45 V A 0 V 0.8 A 90 V 0.5 A 4 V A 48 V 0. A V 0. A 0 V 0. A 4 V A 48 V 0. A V 0. A 0 V 0. A Terminal parts Type of terminals fine stranded [mm] x x coarse stranded [mm] x x Tightening torque [Nm].5.5 coarse stranded [AWG] No No Tightening torque [lb-in] Weights Product Selection Page - -9

20 Accessories Auxiliary contact blocks on 40-CMN (KTA -) 40-A... (KT --PE...) Auxiliary contact blocks on 40M-K5F (KTA -S) 40M-K-EA.. (KT --PE...) at 40 C ambient temperature A 5A at 0 C ambient temperature A 4A AC B 00 Standard Pilot uty C R 00 Light Oilot uty Rated thermal current Ith Contact class coordination according to NEMA (UL/CSA-standards) Back-up fuses gl, gl A Rated supply current AC-5: C-: 0/40 V A V.5 A 0 V.5 A 90 V 0.75 A 4 V A 48 V 0. A V 0. A 0 V 0. A 440 V 0.04 A V A 0/40 V A /45 V A 48 V 0.5 A V 0. A 0 V 0. A Terminal parts Type of terminals fine stranded [mm] x coarse stranded [mm] x Tightening torque [Nm]....5 coarse stranded [AWG] No Tightening torque [lb-in] Weights Accessorie connections 4 ( C/O) 0 ( C/O) Auxiliary contact blocks on 40M-M5F + 40M-P5F (KTA -S + KTA -S) 40M-P-EA (KT --PE-...) Trip contact blocks on 40-MN (KTA -5) 40-T... (KT -5-PF...) at 40 C ambient temperature 5A A at 0 C ambient temperature 4A 4A AC B 00 Standard Pilot uty C R 00 Light Pilot uty Rated thermal current Ith Contact class coordination according to NEMA (UL/CSA-standards) Back-up fuses gl,gl A Rated supply current AC-5: V A 0/40 V A /45 V A 0/40 V A /45 V A 0 V 0.8 A 90 V 0.5 A C-: 48 V 0.5 A V 0. A 0 V 0. A 4 V A 48 V 0. A V 0. A 0 V 0. A Terminal parts Type of terminals fine stranded [mm] coarse stranded [mm] Tightening torque [Nm] coarse stranded [AWG] Tightening torque [lb-in] Weights x Accessorie connections x No ( C/O) 0 ( C/O) Product Selection Page - -0

21 Accessories Trip contact blocks on 40-CMN (KTA -) 40-CT... (KT --PF...) Integrated short-circuit contact in 40-CUV (KT --UA) and 40-CRT (KT --AA) at 40 C ambient temperature A A at 0 C ambient temperature A A Rated thermal current Ith Contact class coordination according to NEMA (UL/CSA-standards) Closed Open max. Voltage 480 V AC B 00 Standard Pilot uty 4 VA 7 VA C R 00 Light Pilot uty 8 VA 8 VA Back-up fuses gl, gl V A Rated supply current AC-5: 0 V A V.5 A 0 V.5 A 90 V 0.75 A C-: 4 V A 48 V 0. A V 0. A 0 V 0. A 440 V 0.04 A AC-4: 4 V.5 A V.5 A 0 V.0 A V.0 A C-: 4 V.5 A 48 V 0.5 A 0 V 0.4 A V 0. A 0 V 0.75 A Terminal parts Type of terminals fine stranded [mm] x x coarse stranded [mm] x x Tightening torque [Nm] coarse stranded [AWG] No No Tightening torque [lb-in] Weights Auxiliary contact- and trip contact blocks on 40M-K5F (KTA -S) 40M-K-ER (KT --PF) and 40M-K-EAR- (KT --PE-PF) Auxiliary contact- and trip contact blocks on 40M-M5F and 40M-P5F (KTA -S and KTA -S) 40M-P-ER (KT --PF) and 40M-P-EAR (KT --PE-PF) at 40 C ambient temperature 5A 5A at 0 C ambient temperature 4A 4A Rated thermal current Ith Contact class coordination according to NEMA (UL/CSA-standards) AC C Back-up fuses gl,gl Rated supply current AC-5: V A 0/40 V A /45 V A V A 0/40 V A /45 V A C-: 48 V 0.5 A V 0. A 0 V 0. A 48 V 0.5 A V 0. A 0 V 0. A Weights (40M-K-ER (KT --PF)) 5 (40M-K-EAR (KT --PE-PF)) (40M-P-ER (KT --PF)) 5 (40M-P-EAR (KT --PE-PF)) Product Selection Page - -

22 Accessories Undervoltage trip for right side mounting on 40-MN (KTA -5) 40-UV... (KT -5-UA...) Undervoltage trip on 40-CMN (KTA -) 40-CUV... (KTA --UA...) Actuating voltage Pull-in x Us x Us rop-out x Us x Us On-Time Rated control voltage % E % E min.: V Hz/4 V 0 Hz V Hz/4 V 0 Hz max.: 00 V Hz 00 V Hz Pull-in 8.5 VA, W on request Hold VA,. W on request fine stranded [mm] x x coarse stranded [mm] x x Tightening torque [Nm] Coil rating Terminal parts Type of terminals coarse stranded [AWG] No No Tightening torque [lb-in] Undervoltage trip on 40M-K5F (KTA -S) 40M-K-U.. (KT --UA-...) Undervoltage trip on 40M-M5F and 40M-P5F (KTA -S and KTA -S) 40M- P-U.. (KT --UA-...) Weights Actuating voltage Pull-in x Us x Us rop-out x Us x Us V V Rated control voltage AC C Coil rating Weights 4... V.7 VA 4.5 VA.0 W Shunt trip for right side mounting on 40-MN (KTA -5) 40-RT... (KT -5-AA...) Shunt trip on 40-CMN (KTA -) 40-CRT... (KT --AA...) x Us x Us Actuating voltage Pull-in rop-out On-time % E % E V Hz/4 V 0 Hz V Hz/4 V 0 Hz Rated control voltage min.: max.: 00 V Hz 00 V Hz Pull-in 8.5 VA, W on request Hold VA,. W on request fine stranded [mm] x x coarse stranded [mm] x x Tightening torque [Nm] Coil rating Terminal parts Type of terminals coarse stranded [AWG] No No Tightening torque [lb-in] Weights Product Selection Page - -

23 Accessories Shunt trip on 40M-K5F (KTA -S) 40M-K-A.. (KT --AA-...) Shunt trip on 40M-M5F and 40M-P5F (KTA -S and KTA -S) 40M-P-A.. (KT --AA-...) x Us x Us Actuating voltage Pull-in rop-out Rated control voltage AC V V C 4... V 4... V 0 VA 80 VA 0 W 80 W 4 4 Coil rating Weights Current limiter 40-CL (KTL --N) Rated insulation voltage 90 V Continuous current A Rated short-circuit breaking capacity Icn Thermal release Magnetic release Setting range Pick-up current Circuit-breaker 40-MN (KTA -5) Circuit-breaker 40-MN (KTA -5) with Current limiter Breaking capacity Icn Coordination according to IEC 947-, Hz at: Breaking capacity Icn Coordination according to IEC 947-, Hz at 0/40 V /45 V 0 V 90 V 0/40 V /45 V 0 V 90 V Icu Ics Icu Ics Icu Ics Icu Ics Icu Ics Icu Ics Icu Ics Icu Ics Terminal parts No., 4, (top) No..,, 5 (bottom) Type of terminals fine stranded [mm] x x 4... coarse stranded [mm] x x... 5 Tightening torque.5.5 coarse stranded [AWG] No No Tightening torque [lb-in] Weights [Nm] 0... Ics Rated Short-circuit-breaking capacity Icu Short-circuit breaking capacity limit Performance categories coordination according to IEC 947-: Icu still able to function following test O-t-CO Ics Fully serviceable following test O-t-CO-t-CO O = Open CO = Reclose and open t = efined interval Product Selection Page - -

24 Accessories Terminal blocks 40-L (KT -5-A) Terminal parts Type of terminals Terminal blocks 40-L (KT -5-A) No.., 4, (oben) No..,, 5 (bottom) No..,, 5 x 4... fine stranded [mm] x x 4... coarse stranded [mm] x x... 5 Tightening torque [Nm] coarse stranded [AWG] No No No Tightening torque [lb-in] Weights 5 Compact bus-bars 40-L45... (KT -5-B ) Compact bus-bars 40-L... (KT -5-B ) Rated isolation voltage 90 V 90 V Rated thermal current Ith A Weights L45 40-L45 40-L L455 A (KT -5-B-45-) (KT -5-B-45-) (KT -5-B-45-4) (KT -5-B-45-5) L 40-L 40-L 40-L (KT -5-B-54-) (KT -5-B-54-) (KT -5-B-54-4) (KT -5-B-54-5) Blank space cover 40-L (KT -5-BA) Weight. Enclosure 40-E4 (KT -5-KA) Enclosure 40-E55 (KT -5-KAZ) IP4 IP55 (with seal and protective diaphragm) C C 58 Protection class Ambient temperature Weights Button membrane 40-N8 (KT -5-M) Weight 8 Indicator light 40-L... (KT -5-L...) Protection class IP54 Ambient temperature Weight Weights Weights V, 40 V, V Weights Weight Locking arrangement 40-N (KT -5-S) Locking arrangement 40-N4 (KT -5-SC) Screw adapter 40-N (KT -5-AS) 9 Lockable rotary handle 40-K... (KT --K..) Lockable rotary handle 40-.-K. (KT -...-H..) 0 Complete door coupling assembly 40M-K-54N (KT --HRB) Complete door coupling assembly 40M-P-54N (KT --HRB) 0 Replacement shaft 40M-P-S (KT --HTA) Weights 90 Locking arrangement for toggle for 40M-K5F (KTA -S) 40M-K-M (KT --SA) Locking arrangement for toggle for 40M-M5F and 40M-P5F (KTA -S and KTA -S) 40M-P-M (KT --S) 0 0 Product Selection Page - -4

25 Accessories Remote operators for 40M-K5F (KTA -S) 40M-K-PF (KT --FA) Remote operators for 40M-M5F (KTA -S) 40M-M-PF (KT --FA) Remote operators for 40M-P5F (KTA -S) 40M-P-PF (KT --FA) AC... 5 V, 0 V... 5 V, 0 V... 5 V, 0 V C... 5 V, 0 V... 5 V, 0 V... 5 V, 0 V Rated actuating voltage Us Operating range Making operation x Us x Us x Us AC 0 VA 0 VA 000 VA C 0 W 0 W 000 W Total closing time ms ms ms Total breaking time ms ms ms Reset time ms ms ms Power input Weights Weight Locking arrangement for all remote operators 40M-P-Q (KT --FA-S) Weights Terminal cover for 40M-K5F (KTA -S) 40M-K-C (KT --HA) Terminal cover for 40M-M5F (KTA -S) 40M-M-C (KT --HA) Terminal cover for 40M-P5F (KTA -S) 40M-P-C (KT --HA) Product Selection Page - -5

26 Circuit-Breaker (Bulletin 40) / Contactor (Bulletin -M, Bulletin -C, Bulletin CAB) Coordination Table Type Coordination according to IEC Possible Short-circuit Current Iq = ka Voltage: /45 V, Hz Standard motors AC- at /45 V Circuit-breaker Cat. No. Thermal overload release Magnetic release Setting range Response current Current limiter Mini-contactor IAC- Contactor IAC- Cat. No. Cat. No. Cat. No. [kw] MN M C MN M C MN M C MN M C MN M C MN M C MN M C MN M C MN M C MN M C MN M09 -C MN C MN C MN CL -C MN CL -C MN CL -C.0 40-CL MN C CMN C CMN C CMN C CMN C CMN C CMN C M-K5F CAB M-K5F CAB-5 (-EI) M-K5F CAB-40-EI M-M5F CAB-70-EI M-M5F CAB--EI M-M5F CAB--EI M-P5F CAB-00-EI M-P5F CAB-40-EI 40.0 Iq = ka efinition of Type Coordination according to IEC : The contactor or the starter must not endanger persons or systems in the event of a short-circuit. The contactor or the starter need not be suitable for continued operation whithout repairs and parts replacement. amage to the contactor and the overload relay are permissible. Product Selection Page - -

27 Type Coordination according to IEC Possible Short-circuit Current Iq = ka Voltage: /45 V, Hz Standard motors AC- at /45 V Circuit-breaker Cat. No. Thermal overload release Magnetic release Setting range Response current Current Limiter Mini-contactor IAC- Contactor IAC- Cat. No. Cat. No. Cat. No. [kw] MN M C MN M C MN M C MN M C MN M C MN M C MN M C MN M C MN C MN C MN C MN C MN C MN C MN C MN CL -C MN CL -C MN CL -C MN CL -C CMN C CMN C CMN C CMN C CMN C CMN C M-K5F CAB M-K5F CAB-5 (-EI) M-K5F CAB-40-EI M-M5F CAB-70-EI M-M5F CAB--EI M-M5F CAB--EI M-P5F CAB-00-EI M-P5F CAB-40-EI CL 40-CL Iq = ka efinition Type Coordination according to IEC : The contactor or the starter must not endanger persons or systems in the event of a short-circuit. The contactor or the starter must be suitable for further use. No damage to the overload relay or other parts may occur with the exeption of welding of the contactor or starter contacts provided that these can be easily separated without significant deformation (such as with a screwdriver). In the event of short-circuit, fast opening, current limiting 40 / KTA circuit breakers make it possible to build economical, fully short-circuit coordinated starter combinations in accordance whith IEC , coordination type. In many cases equipment is usually selected according to the rated motor current (whithout overrating the contactor). Product Selection Page - -7

28 Circuit-breaker (KTA ) / Contactor (Bulletin -M, Bulletin -C, CA ) Coordination Table Type Coordination according to IEC Possible Short-circuit Current Iq = ka Voltage: /45 V, Hz Standard motors AC- at /45 V Circuit-breaker Thermal overload release Setting range Type Ref. Magnetic release Response current Current Limiter Type Ref. Mini-Contactor IAC- Cat. No. Contactor IAC- [kw] Cat. No. / Type Ref KTA A M C KTA A M C KTA -5-0.A M C KTA -5-A M C KTA -5-A M C KTA -5-.A M C KTA -5-.A M C KTA -5-.5A M C KTA -5-4A M C KTA -5-4A M C KTA -5-.A M09 -C KTA -5-A C KTA -5-A C KTA -5-A KTL---N -C KTA -5-A KTL---N -C KTA -5-0A KTL---N -C KTA -5-5A KTL---N -C KTA --40A C KTA --40A C KTA --A C KTA --A C KTA --90A C KTA --90A C KTA -S-A CA KTA -S-5A CA -5 (-EI) KTA -S-A CA -40-EI KTA -S-00A CA -70-EI KTA -S-A CA --EI KTA -S-A CA --EI KTA -S-0A CA -00-EI KTA -S-A CA -40-EI 40.0 Iq = ka efinition of Type Coordination according to IEC : The contactor or the starter must not endanger persons or systems in the event of a short-circuit. The contactor or the starter need not be suitable for continued operation whithout repairs and parts replacement. amage to the contactor and the overload relay are permissible. Product Selection Page - -8

29 Type Coordination according to IEC Possible Short-circuit Current Iq = ka Voltage: /45 V, Hz Standard motors AC- at /45 V Circuit-breaker Thermal overload release Setting range Type Ref. Magnetic release Response current Current Limiter Type Ref. Mini-contactor IAC- Type Ref. Contactor [kw] KTA A M C KTA A M C KTA -5-0.A M C KTA -5-A M C KTA -5-A M C KTA -5-.A M C KTA -5-.A M C KTA -5-.5A M C KTA -5-4A C KTA -5-4A C KTA -5-.A C KTA -5-A C KTA -5-A C KTA -5-A C KTA -5-A C KTA -5-A KTL---N -C KTA -5-A KTL---N -C KTA -5-0A KTL---N -C KTA -5-5A KTL---N -C KTA --40A C KTA --40A C KTA --A C KTA --A C KTA --90A C KTA --90A C KTA -S-A CA KTA -S-5A CA -5 (-EI) KTA -S-A CA -40-EI KTA -S-00A CA -70-EI KTA -S-A CA --EI KTA -S-A CA --EI KTA -S-0A CA -00-EI KTA -S-A CA -40-EI 40.0 KTL---N KTL---N Type Ref. IAC- Iq = ka efinition Type Coordination according to IEC : The contactor or the starter must not endanger persons or systems in the event of a short-circuit. The contactor or the starter must be suitable for further use. No damage to the overload relay or other parts may occur with the exeption of welding of the contactor or starter contacts provided that these can be easily separated without significant deformation (such as with a screwdriver). In the event of short-circuit, fast opening, current limiting 40 / KTA circuit breakers make it possible to build economical, fully short-circuit coordinated starter combinations in accordance whith IEC , coordination type. In many cases equipment is usually selected according to the rated motor current (whithout overrating the contactor). Product Selection Page - -9

30 Cut-off Current Îs The prospective short-circuit current Icc is effectively limited by the 40-MN (KTA -5) circuit-breaker. I is the maximum value of the cut-off current (instantaneous peak value of the limited let-through current. The value as a function of the prospective short-circuit current is shown in the diagrams I Icc asim. Icc sim. Circuit-breaker 40-MN (KTA -5) Maximum cut-off current Rated operating voltage V Maximum cut-off energy Rated operating voltage V 0.5 0/5 A cos = A A A.5 A. A Prospective short-circuit current Icc Circuit-breaker 40-MN (KTA -5) with current limiter 40-CL (KTL --N) Maximum cut-off current Rated operating voltage V 4.0 A.5 A Maximum cutoff energy A Maximum cutoff current I 0/5 A A 0.9 i dt [As]. A A. A Prospective short-circuit current Icc Maximum cut-off energy Rated operating voltage V 0.5 0/5 A cos = 0. A 0.5 A 0.95 Maximum cutoff energy i dt [As] 0.9 0/5 A A Maximum cutoff current I A Prospective short-circuit current Icc Prospective short-circuit current Icc Product Selection Page - -0

31 Circuit-breaker 40-CMN (KTA -) Maximum cut-off current Rated operating voltage 45 V Maximum cut-off energy Rated operating voltage 45 V 0.5 cos = I 0.8 Maximum cutoff energy Maximum cutoff current 90 A A 40 A 5 A i dt [As] 90 A Prospective short-circuit current Icc A 40 A 5 A Prospective short-circuit current Icc Circuit-breaker 40M-K5F P5F (KTA -S... KTA -S) Maximum cut-off energy Maximum cut-off current Rated operating voltage V Rated operating voltage V I i dt [As] 40M-K5F(4) (KTA -S(4)) 40M-M5F(4) (KTA -S(4)) 40M-P5F(4) (KTA -S(4)) Prospective short-circuit current Icc Maximum cutoff energy Maximum cutoff current 40M-K5F(4) (KTA -S(4)) 40M-M5F(4) (KTA -S(4)) 40M-P5F(4) (KTA -S(4)) Prospective short-circuit current Icc Product Selection Page - -

32 Time / Current Characteristic Circuit-breaker 40-CMN (KTA -) Tripping time [s] Circuit-breaker 40-MN (KTA -5) Tripping time [s] Multiple of the set current IeF ) Thermal release trip current: The adjustable inverse bimetal trip reliably protects motors against overloads. The curve shows the mean operating current at an ambient of 0 C starting from cold. Careful testing and setting ensures effective motor protection even in the case of singlephasing. Protection of EEx eii motors: A requirement of the German standard VE 0/8 is that the operating time of a thermal overload trip starting from cold must be less than the permissible heating time te of the motor. The relevant time / current characteristics must be available at the place of installation. If necessary, they can be obtained from the local sales office. According to VE 0/8, clause..4..., motor protection devices in new installations must provide protection even if one of the external connections is interrupted. 40-MN (KTA -5) circuit-breaker fulfils this requirement for motors with ratings up to kw. Additional protection must be provided to comply with it and also the requirement relating to the interruption of an external connection for motors with ratings higher than kw. 40-CMN (KTA -) circuit-breakers fulfill both requirements for all motor ratings. Multiple of the set current IeF ) Magnetic release trip current: The instantaneous magnetic trip has a fixed operating current setting. This corresponds to times the highest setting of the thermal overload trip. At the upper thermal release setting, this tripping current is times (40-MN / KTA -5 circuit-breaker) or 4 times (40-CMN / KTA - circuit-breaker) the set current; at a lower setting it is correspondingly higher. Current setting IeF: The overload trip corresponds to a thermal overload relay in a motor starter conforming to IEC 9-. If a different value is prescribed (e.g.reduced Ie for cooling medium having a temperature higher than 40 C or a place of installation higher than 000 m above sea level), the setting current is equal to the reduced rated current Ie of the motor. Note: The Bulletin 40 is only used for short-circuit protection in certain applications. The overload protection is provided by a thermal overload relay. Typical examples are variable speed motors, star / delta starters for heavy duty (high intertia) starting and / or an inadequately rated motor feeder. To ensure that only the downstream thermal overload relay trips, the set current IeF on the Bulletin 40 must be increased by 0 %. Product Selection Page - -

33 40M-K5F(4) (KTA -S(4)) 40M-M5F(4) (KTA -S(4)) Tripping time [s] Tripping time [s] Multiple of the set current IeF Multiple of the set current IeF 40M-P5F(4) (KTA -S(4)) Tripping time [s] The time / current characteristic curves showing the mean value at an ambient temperature of 5 C starting from cold. The permissible variation is ± 5 % of the mean value. Multiple of the set current IeF Product Selection Page - -

34 Protection of PVC Insulated Cables against Overload and Short-Circuits Minimum Cu cross-section protected at V Hz mm mm 4 mm.5 mm.5 mm mm 0.75 mm 40-MN-0 (KTA -5-4A) 40-MN-00 (KTA -5-.A) 40-MN-0 (KTA -5-A) 40-MN-0 (KTA -5-A) 40-MN-000 (KTA -5-0A) 40-MN-0 (KTA -5-5A) 40-CMN-0 (KTA --5A) 40-CMN-0 (KTA --40A) 40-CMN-00 (KTA --A) 40-CMN-9000 (KTA --90A) Conforming to IEC 4 and CENELECharmonisation document 84- und The overload protection on Bulletin 40 circuit-breakers is an adjustable thermal trip.. The maximum trip tri tri current is considerably lower than when using fuses for overload protection. Shortcircuit protection is provided by a magnetic trip having a fixed setting. It o ens the main contacts at high sspeed. eed. opens The lower total rupture time reduces the temperature rise of the conductors due to the fault fault. Product Selection Page - -4

35 Selectivity of Incoming circuit-breaker: Outgoing circuit-breaker: Ue: 40-CMN (KTA -) 40-MN (+ 40-CL) (KTA -5 (+ KTL --N)) Incoming circuit-breaker V, Hz l l l Outgoing circuit-breaker Outgoing circuit-breaker: 40-MN (KTA -5) Incoming circuit-breaker: 40-CMN (KTA -)...5 A Current range Current limiter A A...90 A Max. setting of the magnetic releases (4x) A 50 A 88 A A Selective to Not selective (series connection) Incoming feeder circuit-breaker: 40M-K5F (KTA -S) Outgoing feeder circuit-breaker: 40-MN (+ 40-CL) (KTA -5 (+ KTL --N)) Ue: V, Hz Outgoing circuit-breaker: 40-MN (KTA -5) Incoming circuit-breaker: 40M-K5F (KTA -S) A...5 A 5... A Max. setting of the magnetic releases Current range Current limiter CL (+ KTL --N) CL (+ KTL --N) + 40-CL (+ KTL --N) CL (+ KTL --N) 0 A A 900 A Selective to Not selective Product Selection Page - -5

36 Selectivity of Incoming circuit-breaker: Outgoing circuit-breaker: Ue: 40M-M5F (KTA -S) 40-MN (+ 40-CL) (KTA -5 (+ KTL --N)) Incoming circuit-breaker V, Hz l l l Outgoing circuit-breaker Outgoing circuit-breaker: 40-MN (KTA -5) Incoming circuit-breaker: 40M-M5F (KTA -S)...00 A A Max setting of the pick-up current of magnetic trip Current range Current limiter CL (+ KTL --N) CL (+ KTL --N) CL (+ KTL --N) CL (+ KTL --N) 4 A 000 A Selective to Incoming feeder circuit-breaker: 40M-P5F (KTA -S) Outgoing feeder circuit-breaker: 40-MN (+ 40-CL) (KTA -5 (+ KTL --N)) Ue: V, Hz Outgoing circuit-breaker: 40-MN (KTA -5) Incoming circuit-breaker: 40M-P5F (KTA -S)...0 A 0... A Max setting of the pick-up current of magnetic trip Current range Current limiter CL (+ KTL --N) CL (+ KTL --N) CL (+ KTL --N) CL (+ KTL --N) 800 A 4800 A Selective to Product Selection Page - -

37 imensions imensions in mm (inches) Ë Ì Ê Ê Can be attached to IN-rail EN 0-5 Ë Auxiliary contact block for side mounting 40-A (KT -5-PA) Ì 40-RT (KT -5-AA) shunt release or 40-UV (KT -5-UA) undervoltage release 40-MN (KTA -5) Mounting position 40-MN (KTA -5) 40-CMN (KTA -) Mounting position 40-CMN (KTA -) Product Selection Page - -7

38 imensions imensions in mm (inches) 40-CL (KTL --N) 40-MN (KTA -5) mounted to 40-CL (KTL --N) 40-L (KT -5-A) 40-L (KT -5-A) 40-MN (KTA -5) with 40-L (KT -5-A) 40-MN (KTA -5) with 40-L... (KT -5-B...) ø 4.8 (/) 40-N (KT -5-AS) 40-E4 (KT -5-KA) Can be attached to IN rail EN 0-5 Product Selection Page - -8

39 imensions imensions in mm 40M-K5F (KTA -S) 40M-K5F4 (KTA -S4) 40M-M5F (KTA -S) 40M-M5F4 (KTA -S4) 40M-P5F (KTA -S) 40m-P5F4 (KTA -S4) Mounting position / Safety Clearance 40M-K5F... 40M-P5F (KTA -S... KTA -S) Product Selection Page - -9

40 imensions imensions in mm Notch Type A min. A max. 40M-K5F (KTA -S) M-M5F (KTA -S) 40M-P5F (KTA -S) M-.-54N (KT -/-HRB) 40M-K-PF (KT --FA) 40M-M-PF (KT --FA) 40M-P-Pf (KT --FA) Product Selection Page - -40

KT4 Manual Motor Starter

KT4 Manual Motor Starter KT4 Manual Motor Starter Ideal for use as a manual starter The KT4 is a manual motor starter that employs the features of power switching, thermal overload protection and control circuit signaling in one

More information

Ideal for use as a manual starter

Ideal for use as a manual starter Manual Motor Starter Ideal for use as a manual starter The is a manual motor starter that employs the features of power switching, thermal overload protection and control circuit signaling in one compact

More information

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427 Data sheet CI-TI TM Contactors and Motor Starters Circuit Breakers November 2002 DKACT.PD.C00.L2.02 520B1427 Introduction Circuit breakers/manual motor starters cover the power ranges 0.09-12.5 kw This

More information

FMotor Circuit Controllers

FMotor Circuit Controllers Technical Information Motor Circuit Controller IEC Performance Data Catalog Number KTA7-25S...32S 0.16A 0.25A 0.4A 0.63A 1A 1.6A 2.5A 4A 6.3A 10A 16A 20A 25A 29A 32A Rated Operational Current, I e [A]

More information

Technical Information

Technical Information -100 Controller IEC Performance Data (CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device Catalog No. -100... 25A 40A 63A 90A Maximum Short-Circuit Current 480V [ka] 65 65 42

More information

ACS motor protection circuit breakers KT 7 Introduction

ACS motor protection circuit breakers KT 7 Introduction Introduction Automatic Type 2 coordination The right circuit breaker for all applications The KT 7 circuit breaker family consists of two basic frame sizes of mm and 5 mm in three variations with different

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

KT4 Manual Motor Starters

KT4 Manual Motor Starters s General Description...F99 Quick Selection Guide...F100 Accessories...F101 Contact Blocks...F101 Adapter Plates...F101 Release Modules...F102 Connecting Modules...F102 Mounting...F103 Enclosures...F103

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator

More information

Manual Motor Starters. Meta-MEC

Manual Motor Starters. Meta-MEC Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters

More information

3 - Protection components Motor circuit-breakers

3 - Protection components Motor circuit-breakers Contents 0 - Protection components Motor circuit-breakers protection components for the motor protection Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

Protection Equipment

Protection Equipment Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

Bulletin 140M Motor Protectors

Bulletin 140M Motor Protectors 0Circuit Breaker Bulletin 140M Bulletin 140M Cat. No. 140M-C2E Cat. No. 140M-F8E Current Range 0.1...45 A With 140-CMN up to 90 A Type 2 Coordination with Bulletin 100-C Contactors UL Listed Self-protected

More information

Manual Motor Starters

Manual Motor Starters Leader in Electrics & Automation Meta-MEC Manual Motor Starters Electric Equipment LG Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 45 mm 70 mm 63AF 100AF 3 LG Meta-MEC

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

General data 5/37. Overview

General data 5/37. Overview General data Overview Benefits High short-circuit breaking capacity in the feeder Optimum usability in motor feeders for the special voltages 440 V, 480 V, 0 V and 690 V Compact design The are available

More information

Motor Protection Circuit Breaker and Motor Circuit Protector Specifications

Motor Protection Circuit Breaker and Motor Circuit Protector Specifications Technical Data Motor Protection Circuit Breaker and Motor Circuit Protector Specifications Bulletin Number 140M Topic Page Bulletin 140M Motor Protection Circuit Breakers 3 Overview 3 Catalog Number Explanation

More information

Protection Equipment. 5/2 Introduction

Protection Equipment. 5/2 Introduction Protection Equipment /2 Introduction SIRIUS 3RV2 Motor Starter Protectors/ Circuit Breakers up to 40 A /6 General data /12 For motor protection /14 For motor protection with overload relay function /1

More information

Technical data for manual motor starters Type MS325

Technical data for manual motor starters Type MS325 for manual mor starters Type MS325 General data Rated voltage 600 V Rated current 25 A (14 setting ranges, 0.1 25A) Rated frequency 50-60 Hz Electrical and mechanical life endurance 100,000 operations

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

3VU13, 3VU16 Circuit-Breakers

3VU13, 3VU16 Circuit-Breakers 3VU3, 3VU6 Circuit-Breakers Description The 3VU3, 3VU6 circuit-breakers are compact circuit-breakers for currents up to 80 A which operate according to the current limiting principle. The devices are used

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates Motor Starter Protectors/Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates Overview Enclosures For stand-alone installation of 3RV20

More information

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2. Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv

More information

CI-TI Contactors and motor starters Types CI 61 - CI 98

CI-TI Contactors and motor starters Types CI 61 - CI 98 Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include

More information

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J Protection Equipment Siemens AG 2015 Click on the Article No. in the catalog PDF to access it in the Industry Mall and get all related information. Article-No. 3RA1943-2C 3RA1943-2B 3RA1953-2B 3RA1953-2N

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 160 87045 LIMOGES Cedex Phone :+33 05 55 06 87 87 Fax :+33 05 55 06 88 88 DPX 3 160 CONTENTS PAGES 1. USE 1 2. RANGE 1 3. DIMENSIONS 1 4. OVERVIEW 2 5. ELECTRICAL AND MECHANICAL CHARACTERISTICS 3 6. CONFORMITY

More information

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

D509E. Manual Motor - Starters

D509E. Manual Motor - Starters D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors

More information

Technical Information

Technical Information Technical Information KT7 Controller Time-Current Characteristic KT7 Manual Motor Starter/Protector 1. Thermal Release Trip Current The adjustable current-dependent delayed bimetal release protects motors

More information

cor Long Run Experience

cor Long Run Experience Moulded Case Circuit Breakers Moulded Case Circuit Breakers 16-1250A cor Long Run Experience cor Breaking capacity (according to IEC 947-2 at 415V) Icu 100 D160L D250L D400L D630L 70 60 DH800 50 35 30

More information

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories Page 1 of 5 MS132-10 ABB contact for United States of America General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: MS132-10 1SAM350000R1010 4013614400100 MS132-10

More information

Vistop TM isolating switches 63 to 160A

Vistop TM isolating switches 63 to 160A DX 3 - IS main switches 16 to 125A Vistop TM isolating switches 63 to 160A 225 15 225 18 4 064 00 4 064 59 Pack Cat. No. Main switches AC 22 A category as per EN607-3 Grey handle Accept 1 signalling auxiliary

More information

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector Catalog 0500CT9702R409 2009 Class 525/580 CONTENTS Description............................................. Page General Characteristics...................................

More information

PKZ and PKE motor-protective circuit-breakers

PKZ and PKE motor-protective circuit-breakers PKZ and PKE motor-protective circuit-breakers Machinery and installation downtimes should be kept as short as possible. The PKZ fuseless motor-protective circuit-breakers combine short-circuit and overload

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed

More information

Technical Information

Technical Information Miniature Technical Information -09-12 Rated Insulation Voltage U i to IEC947-1 [V] 690V UL/CS [V] 600V Rated Impulse Voltage Withstand U imp [kv] 6 Rated Voltage Ue-Main Contacts C 50/60Hz [V] 230, 240,

More information

Motor Protection Circuit Breakers 3VU13 and 3VU16

Motor Protection Circuit Breakers 3VU13 and 3VU16 Motor Protection Circuit Breakers 3VU13 and 3VU16 3VU13/3VU16 is suitable for use in fuseless motor feeders upto 11KW/22KW (25A/63A) respectively. 3VU motor protection circuit breakers are used for protection

More information

ASL09..S 3-pole Contactors - Spring Terminals

ASL09..S 3-pole Contactors - Spring Terminals 4 kw 5 hp ASL09..S 3-pole Contactors - Spring DC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Low coil consumption, - Polarity on the coil

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s series of UL are UL489 and CE listed for global applications. The current

More information

MS General Information Extended Product Type: MS

MS General Information Extended Product Type: MS MS132-1.6 General Information Extended Product Type: MS132-1.6 Product ID: 1SAM350000R1006 EAN: 4013614400063 Catalog Description: MS132-1.6 Manual Motor Starter Long Description: The MS132-1.6 manual

More information

Protection components

Protection components Presentation, characteristics Presentation 1 2 3 motor circuit-breakers are 3-pole thermal-magnetic circuit-breakers standards IEC 60947-2 and IEC 60947-4-1. Connection These circuit-breakers are designed

More information

DPX moulded case circuit breakers

DPX moulded case circuit breakers BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.

More information

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction Introduction Introduction Schneider Electric offers a complete line of products for the manual control and protection of motors. This catalog covers those devices designed to meet IEC standards for protection

More information

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

Product index. 4 - Manual motor protectors. Phone: Fax: Web:  - Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00, Low-Voltage Controls and Distribution > Industrial Controls > Protection Equipment > Circuit Breakers/Motor Starter Protectors > Motor Starter Protectors SIRIUS RV up to 00 A RV0-0DA5 CIRCUIT-BREAKER,

More information

A Contactors. Technical Information. CA4 Miniature Contactors. Technical Information A94 CA4. Switching Motor Loads.

A Contactors. Technical Information. CA4 Miniature Contactors. Technical Information A94 CA4. Switching Motor Loads. C4 Miniature Contactors Contactors C4 Rated Insulation Voltage U i to IEC 947-1 [V] 500V UL/CS [V] 600V Rated Impulse Voltage U imp [kv] 8 Rated Voltage U e Main Contacts C 50/60Hz [V] 230, 240, 400, 415,

More information

SIRIUS 3RU2 Thermal Overload Relays

SIRIUS 3RU2 Thermal Overload Relays Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors. The overload relay can be connected directly to

More information

WELCOME TO THE WORLD OF COMPLETE AUTOMATION. Innovative MCS Starter Solutions. MCS Starters and the New Mounting System 141A

WELCOME TO THE WORLD OF COMPLETE AUTOMATION. Innovative MCS Starter Solutions. MCS Starters and the New Mounting System 141A WELCOME TO THE WORLD OF COMPLETE AUTOMATION Innovative MCS Starter Solutions MCS Starters and the New Mounting System 141A Welcome to the Wide World of Allen-Bradley Starters Innovative solutions for state

More information

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4. Product index -....1.3 Features and benefits...1 General information Suitable applications...2 -.3 Motor ratings... Pilot duty ratings and overload trip classes...5 Ordering details Type MS116...6 Type

More information

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101408D0201 25/03/11-30-01-.. / Z-30-01-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

MINIATURE CIRCUIT BREAKER

MINIATURE CIRCUIT BREAKER Technical Article MINIATURE CIRCUIT BREAKER T 146 PURCHASE he Spaceage MCB protects wires and cables automatically against overload and short-circuits in domestic, commercial and industrial installations.

More information

Technical Information

Technical Information C5 C5- C5- C5- C5- C5-550 ➊ 700 860 1000 1200 Rated Insulation Voltage U i to IEC 947-1 [V] 1000V 1000V 1000V 690V 690V UL/CS [V] 600V Rated Impulse Voltage U imp C5-550 / 700 / 860 [kv] 3.5 C5-1000 /

More information

Bulletin 100-D IEC Contactors

Bulletin 100-D IEC Contactors Bulletin 100-D IEC Contactors Electronic and conventional coils AC & DC Integrated PLC interface Low power pick-up & hold-in Wide voltage ranges Complete range of accessories Environmentally friendly Compact

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101412D0201 25/03/11-30-00-.. / Z-30-00-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

F Motor Circuit Controllers. Series KT7 Motor Circuit Controllers. KT4 Manual Motor Starters. General Description...F2

F Motor Circuit Controllers. Series KT7 Motor Circuit Controllers. KT4 Manual Motor Starters. General Description...F2 Series KT7 General...2 Series & KTA3-100 Base Units...4 Series Base Units...6 Series Base Units...8 Accessories...10 Technical Information - KT7...20 Dimensions - KT7...32 Technical Information - KTA3-100...37

More information

MS25, MST25, MS20, MST20

MS25, MST25, MS20, MST20 Versions: - MS25 with thermal and magnetic releases - MST25 with a thermal release - MS20 - with thermal and magnetic releases for single-phase consumers - MST20 with a thermal for single phase consumers

More information

Motor Circuit Breakers C4

Motor Circuit Breakers C4 Motor protection rating up to 100 Amps Short circuit breaking capacity up to 100kA Phase failure protection DIN rail mounting Wide range of accessories Options and ordering codes Model C4/32T Setting Short

More information

Application Mini Contactors for Motors and Resistive Loads

Application Mini Contactors for Motors and Resistive Loads Delivery program Contactor, 4p, 4kW/400V/AC3 Part no. DILEM4-G(24VDC) Catalog No. 012701 Eaton Catalog No. XTMF9A00TD Product range Contactors Application Mini Contactors for Motors and Resistive Loads

More information

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101415D0201 25/03/11 AF30-30-11-.. / AF30Z-30-11-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF30(Z) contactors are used for controlling power circuits

More information

Thermal magnetic and trip-free switches

Thermal magnetic and trip-free switches 87045 LIMOGES Cedex Phone : 33 05 55 06 87 87 Fax : 33 05 55 06 88 88 DPX 3 1600 Reference(s : 422 250 /251/ 252/ 253/ 254/ 255 /256/ 262/263/ 264/ 265/ 266/ 267/268/ 269/ 270/ 271/ 272/ 273/ 278/ 287/

More information

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting. DATASHEET - ZB12-2,4 Delivery program Overload relay, 1.6-2.4 A, 1N/O+1N/C Part no. ZB12-2,4 Catalog No. 278437 Eaton Catalog No. XTOB2P4BC1 EL-Nummer 0004131832 (Norway) Product range Overload relay ZB

More information

Motor Controllers + Circuit Breakers

Motor Controllers + Circuit Breakers Series General...2 Series & KTA3-100 Base Units...4 Series Base Units...6 Series Base Units...8 Accessories...10 Technical Information -...20 Dimensions -...33 Technical Information - KTA3-100...39 Dimensions

More information

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI . Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,

More information

Star Series Motor protection & control

Star Series Motor protection & control Contact us ABB Inc. Low Voltage Control Products 16250 W. Glendale Drive New Berlin, WI 53151 Phone: 888-385-1221 Fax: 800-726-41 USA Technical support & Customer Service: 888-385-1221, Option 4 7:30AM

More information

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors MOTOR STARTERS SM Basic function Switching and protection of motors up to A Protection against short-circuit and protection against overload The device responds to phase failure The device is provided

More information

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1. 87045 LIMOGES Cedex Téléphone : 05 55 06 87 87 Télécopie : 05 55 06 88 88 LEXIC MCB s DX-H 80A, 100A, 125A Curv urves B and C CONTENTS PAGES 1. Description, use...1 2. Range...1 3. Overall dimensions...1

More information

01 Spectra Plus - Introduction

01 Spectra Plus - Introduction 01 Spectra Plus - Introduction Standard features Conforming to IS13947-2/EN60947 2 Compact dimensions Available in 3P & 4P High performance microprocessor protection release Wide overload setting from

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

Description. Positive safety relays

Description. Positive safety relays Type N & KC Positive safety Description A.C. or D.C. operated DIN rail or panel mounting 600 volt heavy duty design, A600-10 amp, Q300-5 amp Snap-on accessories available: 1 & 4 pole adder deck Pneumatic

More information

Protection Equipment. Overload Relays. Reference Manual 04/2011. Industrial Controls. Answers for industry.

Protection Equipment. Overload Relays. Reference Manual 04/2011. Industrial Controls. Answers for industry. Protection Equipment Overload Relays Reference Manual 04/2011 Industrial Controls Answers for industry. Protection Equipment 2 3 7 7 8 9 14 1 16 17 18 18 19 20 2 26 27 28 29 30 32 37 38 40 42 Introduction

More information

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1 Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC

More information

Product Line Overview. The Most Logically Designed Contact Assembly

Product Line Overview. The Most Logically Designed Contact Assembly Circuit Breakers & Supplementary Protectors 15 00 Amperes for UL, CSA & IEC Applications Product Line Overview -3 General Information Cutler-Hammer Series G Molded Case Circuit Breakers provide increased

More information

Data Sheet Manual Motor Starters Ex9SN Series

Data Sheet Manual Motor Starters Ex9SN Series Data Sheet Manual Motor Starters Ex9SN Series www.noarkusa.com NOARK Ex9SN Series Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors

More information

Bulletin 825 SMM Smart Motor Manager

Bulletin 825 SMM Smart Motor Manager Bulletin 825 SMM Smart Motor Manager Your order must include: Cat. no. of the Smart Motor Manager selected with supply Voltage Suffix Code, Cat. no. of Converter Module selected, and, If required, Cat.

More information

Bulletin 193-T1 Bimetallic Overload Relays

Bulletin 193-T1 Bimetallic Overload Relays Bulletin 193T1 Bimetallic Overload Relays Overload protection trip class 10 / 10A Phase loss protection Ambient temperature compensation Auxiliary contacts (1 N.O. and 1 N.C.) Manual/automatic reset mode

More information

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Thermal-magnetic Miniature Circuit Breaker 4230-T... Thermal-magnetic Miniature Circuit Breaker 40-T... Description Single pole and multipole thermal-magnetic miniature circuit breakers (MCBs) in accordance with EN 60947-, UL 1077 and UL 489 for DIN rail

More information

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD. DATASHEET - DILMC9-10(24VDC) Technical data General Contactor, 3p+1N/O, 4kW/400V/AC3 Part no. DILMC9-10(24VDC) Catalog No. 277468 Eaton Catalog No. XTCEC009B10TD EL-Nummer 4110305 (Norway) Standards IEC/EN

More information

Selection Guide Motor Control Device Solutions

Selection Guide Motor Control Device Solutions Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements

More information

Essential equipment for all your requirements

Essential equipment for all your requirements NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides

More information

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage SENTRON Configuration Manual Edition 10/2015 siemens.com/lowvoltage 2 Introduction LD main control and EMERGENCY-STOP switches up to 250 A 4 Introduction 7 Front mounting 10 Floor mounting 11 Distribution

More information

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line Motors Automation Energy Transmission & Distribution Coatings Automation Contactors - CWM Line 2 Contactores Compactos CWC0 Contactors - CWM Line Sumary Presentation Accessories Overview 5 Three-Pole Contactors

More information

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories Manual motor protectors Manual motor protectors Manual motor Protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL Listed and CSA certified

More information

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

The breakers offer thermal-magnetic trip protection according to Z and K characteristics. Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific

More information

Approved Standards. Ordering Information. Thermal Overload Relay J7TKN. Model Number Legend. Thermal Overload Relay. Accessories

Approved Standards. Ordering Information. Thermal Overload Relay J7TKN. Model Number Legend. Thermal Overload Relay. Accessories Thermal Overload Relay J7TKN ) Thermal Overload Relay Direct and separate mounting Single phasing sensivity according to IEC 60947-4-1 Finger proof (BGV A2) Accessories Set for single mounting Approved

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet SBC042D020 06/04/ -22-00-.. / Z-22-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440 V DC.

More information

Modular contactors and relays

Modular contactors and relays pages /4 to / pages /8 and /9 pages /10 and /11 pages /12 and /13 Presentation and standards Presentation Designed for use in modular panels and enclosures, these contactors feature : i Easy installation

More information

and other modular devices for low voltage installation

and other modular devices for low voltage installation Technical catalogue System and other modular devices for low voltage installation 2CSC400002D0204 SUMMARY Introduction Miniature Circuit-Breakers Residual Current Devices Auxiliary elements and accessories

More information

Control and Load Switch Specifications Bulletin Number 194E, 194L

Control and Load Switch Specifications Bulletin Number 194E, 194L Technical Data Control and Load Switch Specifications Bulletin Number 194E, 194L Topic Page Product Line Overview 2 194E General Specifications 3 194E Approximate Dimensions 5 194L Circuit Diagrams 13

More information

Protective Devices: Circuit-Breakers 1 )

Protective Devices: Circuit-Breakers 1 ) Protective Devices: Circuit-Breakers 1 ) /2 Introduction SIRIUS circuit-breakers 1 ) up to 100 A / General data /20 For motor protection /22 For motor protection with overload relay function /23 For starter

More information

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer DATASHEET - ZB65-65 Delivery program Overload relay, 50-65A, 1N/O+1N/C Part no. ZB65-65 Catalog No. 278460 Eaton Catalog No. XTOB065DC1 EL-Nummer 0004131855 (Norway) Product range Overload relay ZB up

More information

The Complete Range up to 710 kw. Overview Contactors

The Complete Range up to 710 kw. Overview Contactors The Complete Range up to 710 kw Overview Contactors Rockwell Automation Contactors - the Complet Motor rating AC-3, 400 V 2.2 kw 4.0 kw 5.5 kw 4 kw 5.5 kw 7 Rated operational current 60 C AC-3, 400 V [A]

More information

DEVICE STATE/BYPASSED FAILURE OVERLOAD

DEVICE STATE/BYPASSED FAILURE OVERLOAD Technical specifications Type 5. 7. Control electronics Rated values Terminal Rated control supply voltage A1A2 V AC 115 230 115 230 Tolerance % -15+10-15+10 Rated control supply STANDBY ma 15 15 Rated

More information

IEC Load Switches Bulletin 194E 25 Amps to 100 Amps

IEC Load Switches Bulletin 194E 25 Amps to 100 Amps Description load switches are designed for use as local motor isolation and IEC disconnect switch applications outside North America. Available with 3- and 6-pole versions with add-on additional poles,

More information