Installation Relays. Power Relays Step-on Step-off Relays Staircase Lighting Timers Power Step-on Step-off Relays Installation Contactors 103 KAT
|
|
- Damon Goodwin
- 5 years ago
- Views:
Transcription
1 Installation elays Installation elays 3 Power elays tep-on tep-off elays taircase ighting Timers Power tep-on tep-off elays Installation Contactors COMAT AG BETAE 4 CH-3076 WOB CHWEIZ Tel. 41 (0) Fax. 41 (0) info@comat.ch 103 KAT
2 otes loyd s; IEC 61810; E Comat products comply with different international standards and are certified accordingly. A detailed list can be found on our web page: 104 KAT COMAT AG BETAE 4 CH-3076 WOB CHWEIZ Tel. 41 (0) Fax. 41 (0) info@comat.ch
3 Installation elays tep-on tep-off elays eries Time range ocket type Contact tep-on tep-off elays CIM1 0,6s-60min DI 35 16A 106 taircase ighting Timer tep-on tep-off elay C1C DI 35 6A 106 Page Power elays Power elay B103 DI 35 10A 107 Power elay A333 DI 35 10A 107 Installation elays taircase ighting Timers taircase ighting Timer A1 30s -10min DI 35 10A 108 taircase ighting Timer 30s -10min DI 35 10A 108 taircase ighting Timer A3 30s - 60min DI 35 10A taircase ighting Timer taircase ighting Timer taircase ighting Timer A4 30s -60min DI 35 10A 109 A5 DI 35 10A 109 Installation Contactors Installation Contactor IC20 DI 35 20A 110 Installation Contactor IC25 DI 35 25A 110 Installation Contactor IC40 DI 35 40A 110 Installation Contactor IC63 DI 35 63A 110 AUX Block IC-AUX 6A 110 COMAT AG BETAE 4 CH-3076 WOB CHWEIZ Tel. 41 (0) Fax. 41 (0) info@comat.ch 105 KAT
4 CIM, C DI tep-on tep-off elays tep-on tep-off elays Type: A1 o longer available substituted by CIM1 17,5mm 13 mm tep-on tep-off elay with integrated ED display no external wiring required Mounting on DI rail T35 Test voltage: 2000V / C ailway version up to -46 CIM1 tep-on tep-off elay/ taircase ighting Timer and 7 additional time functions including O/OFF manual switch for maintenance purpose. ED status display and integrated test switch. tep-on tep-off elay with integrated ED display no external wiring required Mounting on DI rail T35 Test voltage: 2000V / C C1C tep-on tep-off elay 13mm series 1 x CO for permanente drive supply failure protected Integrated ED and coil wiring Time ange 0,6s-60h MI 16 A 250VA MI 6A 250VA E Triggering Function (page ) E B W A K B Triggering A1 B1 A1 B1 A1 A1 15 B (DC-version) A1 witching current /voltage witching power AC1 // DC1 witching cycles mech. Operating voltage Power consumption AC/DC Glow lamp load Agi 16A 250V 4000VA // 384W 30 x 10 6 AC ±20% / DC ±20% 1,2VA, 430mW 10 ms / 10 ms 10 ma witching current /voltage witching power AC1 // DC1 witching cycles mech. Operating voltage Power consumption AC 50/60Hz Agi 15A/20ms 1500VA //...180W DC: 10 x10 6 ; DC 15 % AC ±15% / DC ±15 % 2VA 1,5W ecommended triggering time 50ms C1C/AC230V / CIM1/24-240V DC 10% C1C/DC24V B13-K B13-G (incl.paper) 75 T T35 45 tep-on step-off relay CIM1/ V 4,2 17,5 2, tep-on step-off relay C1C/AC230V KAT COMAT AG BETAE 4 CH-3076 WOB CHWEIZ Tel. 41 (0) Fax. 41 (0) info@comat.ch
5 Power elays Power elays B103, A333 DI Power elays with mechanical output status A333 with DI 45mm cap dimension Test voltage: 2000V 2000V / C B103 Power elay 1 pole power relay with free-wheeling diode and reverse polarity protection Integrated ED position indicator A333 Power elay 1 pole power relay with free-wheeling diode and reverse polarity protection Integrated ED position indicator Installation elays 3 MI 10 A 250VA 10 A 250VA 10mA 10V A1 11 A Connection lay out (top/bottom) Data at Tamb = 20 C witching power AC1 // DC1 Peak inrush current witching cycles mech./elec. (AC1) Operating voltage AC50Hz/DC Power consumption AC/DC AC 50/60Hz DC 10% 50/60Hz / AgCdo 2200VA // 150W (DC) 16 A 2x 10 7 AC ±15% / DC ±15 % 2VA, 1,5W 20ms / 12ms , B103 /AC... V 48, 24, 8-12 B103 /... V AgCdo 1500VA // 300W (DC) 30A 2x ,8...1,1U 2,2VA, 1,2W 18 ms / 10 ms 230, 110, 48, 24 A333/AC... V A333/ DC... V 48, 24, 12 A333 Power elay B103/AC V COMAT AG BETAE 4 CH-3076 WOB CHWEIZ Tel. 41 (0) Fax. 41 (0) info@comat.ch 107 KAT
6 A1... A3 DI taircase ighting Timers taircase ighting Timers taircase ighting Timers 120A PEAK taircase ighting Timers Trigger status indication Manual-Auto switch Test voltage: 2500V / C Time ange MI A1 taircase ighting Timers taircase ighting Timers taircase ighting Timers For small to medium-sized installations With special contact for high lamp loads With stepping switch functions and ingle contact 10A, 250Va 120A special early make contact 120A special early make contact 30s-10min running time, infinitely Glow lamp load with AC Glow lamp load with AC adjustable 30s-10min running time, infinitely 30s-1h running time, infinitely adjustable subsequent time operation from zero adjustable subsequent time operation from zero Manual O subsequent time operation from zero Manual O Manual O 30s-10min 30s-10min 30s-60min 10 A 250VA 10 A 250VA (120A peak) 10 A 250VA (120A peak) A3 Function/Triggering B1 Y1 Y2 Y2 Y3 t t 10 A A1 17 B1 10 ma 10 A A1 17 B1 B1 10 A A1 17 B1 Y1 Y2 Y3 Function Triggering (Page ) Y4 Y5 1200W 1200W 2000W witching power AC1 // DC1 Peak inrush current witching cycles mech./elec. (AC1) Operating voltage AC50Hz/DC Power consumption AC/DC Glow lamp load WAgnO2 0,85...1,1U 2,5VA 50ms / 300ms 10 ma WAgnO2 0,85...1,1U 2,5VA 50ms/ 300ms WAgnO2 0,85...1,1U 2,5VA, 1,5W 60ms/ 300ms AC 50/60Hz , A1/AC... V , /AC... V , , A3/AC... V 50/60Hz / 24 A3/... V taircase ighting Timer A1/AC V 108 KAT COMAT AG BETAE 4 CH-3076 WOB CHWEIZ Tel. 41 (0) Fax. 41 (0) info@comat.ch
7 A4... A5 DI taircase ighting Timers taircase ighting Timers Power tep-on tep-off elay 120A PEAK taircase ighting Timers Trigger status indication Electronic switch position indication Test voltage: 2500V 1500V / C Time ange A4 taircase ighting Timers Two-way lighting control on-off, stepping switch 120A special early make contact AC supply for glow lamp 30s-1h running time, infinitely adjustable subsequent time operation from zero Manual O 30s-60min A4C taircase ighting Timers Two-way lighting control on-off, stepping switch 120A special early make contact AC supply for glow lamp 30s-1h running time, infinitely adjustable subsequent time operation from zero Manual O 0,5s-60min A5 Power tep-on tep-off elay tepping switch funct. Central O-OFF 120A special early make contact Output status eon lamps by AC control (Push button illumination up to for glow lamps resp. ED s) Installation elays 3 MI 10 A 250VA (120A peak) 10 A 250VA (120A peak) 10 A 250VA (120A peak) Function (Page ) /Triggering A4 A4C A5 Y1 Y2 Y2 Y3 t t B1 B1 C1 C2 A1 17 B Y1 Y2 Y3 2000W CETA O C1 C2 EET AUTO A1 17 B1 C Y1 Y2 Y3 2000W 24-60V O C1 C2 EET AUTO A1 11 B A3 2000W CETA O OFF C1 C2 A3 CETA C1 C2 O OFF Getrennter teuerkreis. (pannung wie A1-) witching power AC1 // DC1 Peak inrush current witching cycles mech./elec. (AC1) Operating voltage AC50Hz/DC Power consumption AC/DC Glow lamp load WAgnO2 0,85...1,1U 2,5VA, 1,5W 60ms/ 300ms WAgnO2 0,85...1,1U 2,5VA 60ms/ 300ms WAgnO2 0,85...1,1U 2,5VA, 1,5W 60ms/ 300ms AC 50/60Hz , , A4/AC... V , A4C/AC... V 230, A5/AC... V 50/60Hz / 24 A4/... V 24 A3/... V taircase ighting Timer A4/AC V COMAT AG BETAE 4 CH-3076 WOB CHWEIZ Tel. 41 (0) Fax. 41 (0) info@comat.ch 109 KAT
8 IC DI Miniature Contactor Contactor 20A 2O or 2C or 1O/1C Contactor 25A 4O or 4C or 2O/2C Contactor 40A 4O or 4C or 2O/2C Contactor 63A 4O or 2O/2C AUX Block 2O or 2C or 1O/1C O OIE! T35 AC/DC Istallation Contactors o noise! All contacts doublemake/ doublebrake Mechanical status display Test voltage: 4kV/ / C IC20 IC25 IC40 IC63 IC-AUX Contactor 20A Contactor with 2O or 2C or 1O1C contacts. (AC/DC) versions are noise free and do not need external freewheeling circuits. o coil inrush overcurrent. ealing cover optional. Contactor 25A Contactor with 4O or 4C or 2O2C contacts. (AC/DC) versions are noise free and do not need external freewheeling circuits. o coil inrush overcurrent. ealing cover optional. Contactor 40A Contactor with 4O or 4C or 2O2C contacts. (AC/DC) versions are noise free and do not need external freewheeling circuits. o coil inrush overcurrent. ealing cover optional. Contactor 63A Contactor with 4O or 2O2C contacts. (AC/DC) versions are noise free and do not need external freewheeling circuits. o coil inrush overcurrent. ealing cover optional. Auxilary Contactblock with 2O or 2C or 1O1C contacts. For signalling and control applications up to 6A with crown twin contacts. For all IC contactors. and others: MI 20A A 10mA 24V 25A A 10mA 24V 40A A 10mA 24V 63A A 10mA 24V 6AA 5mA 24V 1 A A A A Connection lay out (top/bottom) A A A A A A A witching current I TH witching voltage witching power AC3 witching power AC1/AC7a Op Frequenz max. cycle/hr Electrical life cycles AC1 Coil voltage range Power consumption Operate / release time typ. 2 4 Agi 20A 1,3kW/230V 4kW/230V 600 2x10 5 0,85-1,1 U 2,5W 20ms // 20ms 2 4 Agi 25A 2,2kW/ 16kW/ 600 2x10 5 0,85-1,1 U 3W 10ms // 50ms AgnO 2 40A 5,5kW/ 26kW/ 120 1x10 5 0,85-1,1 U 5W 20ms // 35ms 6 8 AgnO 2 63A 8,5kW/230V 40kW/ 120 1x10 5 0,85-1,1 U 5W 20ms // 35ms Agi 6A 600 2x10 5 // A 50/60Hz / D IC20-200/... V IC25-400/... V IC40-400/... V IC63-400/... V IC-AUX20 A 50/60Hz / D IC20-110/... V IC25-220/... V IC40-220/... V IC63-220/... V IC-AUX11 IC20 IC25-63 A 50/60Hz / D IC20-020/... V IC25-040/... V IC40-040/... V IC-AUX02 Installation contactor IC25-400/230V Aux block IC-AUX20 IC20 IC25 IC40 IC63 IC-AUX 85 T35 45 *Option ealing cover Type: IC-E0 IC-E5 IC-EA40-63 ealing cover IC-E0 17, * 44 (45.5*) KAT COMAT AG BETAE 4 CH-3076 WOB CHWEIZ Tel. 41 (0) Fax. 41 (0) info@comat.ch
functions: --Staircase timer --Staircase timer + maintenance function --Staircase timer with early warning
14 SERES 14 SERES Multi-function electronic staircase timers 1 O 16 A 17.5 mm wide Type 14.01 --8 functions --Switch-off early warning options Type 14.71 --3 functions Time setting from 30 seconds to 20
More informationSOLID-STATE CONTACTORS
SOLID-STATE CONTACTORS For frequent switching without contact bounce No wear and tear and silent operation thanks to semiconductor technology Non-hazardous switching of inductive loads Reduction of switch-on
More information46 and 56 Series - Relays for railway applications 8-12 A. Features 46.52T 56.32T 56.34T
46 and 56 Series - Relays for railway applications 8-12 A Features 46.52T 56.32T 56.34T Plug-in power relays: 8 A, 2 pole 12 A, 2 and 4 pole DC coils with extended range Complies with UNI CEI 11170-3 (protection
More informationMulti-function. Mono-function 1 NO (SPST-NO)
Features Range of electronic staircase timers 17.5 mm wide Time setting from 30 s to 20 min Zero crossing load switching Switch-off early warning - model 14.01 Suitable for 3 or 4 wire systems, with automatic
More information2 pole 10 A PCB mount A1 A
Series - Miniature general purpose relays - 0 A Features Printed circuit mount, general purpose, & Pole relays. - Pole 0 A. - Pole 0 A. - Pole A AC coils & DC coils Cadmium Free contacts (preferred version)
More information55 Series - Miniature General Purpose Relays 5-10 A
Series - Miniature General Purpose Relays -0 A - Plug-in or P.C.B. versions - AC or DC coils - Lockable test button and mechanical flag indicator as standard on and CO relays types - Sockets and accessories:
More informationTime scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)
86 Timer modules 86 Timer modules for use in conjunction with relay & socket. 86.00T - Multi-function & multi-voltage timer module 86.30T - Bi-function & multi-voltage timer module Complies with EN 45545-2:2013
More information40 Series - Miniature PCB relays A. Features
1. = 12.4 1. = 12.4 1. = 12.4 40 Series - Miniature PCB relays 8-10 - 16 A Features 40.31 40.1 40.2 1 & 2 Pole relay range 40.31-1 Pole 10 A (3. mm pin pitch) 40.1-1 Pole 10 A ( mm pin pitch) 40.2-2 Pole
More information0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A 55 Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
More informationContactors and Overloads MC
Contactors and Overloads MC Up to 700A AC3 Up to 00A AC1 DIN rail mounting to 5A, 55kW Add on auxiliary contacts top or side mounted International approvals Designed to EN60971 Compact design for panel
More informationBETA Switching Switching Devices
Siemens AG 200 BETA Switching /2 Product overview /3 5TT4 1 remote control switches /11 5TT4 2 switching relays /14 5TT5 7 Insta contactors, DC technology /20 5TT5 Insta contactors, AC technology /2 5TT3
More informationCommand and signalling E 250, E 259 selection table
E 250, E 259 selection table Latching relays E250 Installation relays E259 Contacts switching on each impulse sent to the control coil. Contacts maintained in switched position only while the control coil
More informationKtec Contactors and thermal overloads
Contactors and thermal overloads Techna KTEC series contactors provide a complete solution for your ac contactor requirements.the range carries TUV, UL & CSA certification, for use in Europe, North America
More information5 mm contact pin pitch PCB or 95 series sockets
1. = 12.4 1. = 12.4 44 Series - Miniature PCB relays 6-10 A Features 44.2 44.62 2 Pole relay range 44.2-2 Pole 6 A ( mm pin pitch) 44.62-2 Pole 10 A ( mm pin pitch) PCB mount - direct or via PCB socket
More informationPluggable interface relays RT, PT and MT range
Content Pluggable interface relays RT, PT, MT Benefits and advantages, approvals... 190 Ordering details... 191 Technical data... 194 Circuit diagrams... 19 Dimensional drawings... 19 189 Benefits and
More informationCO (DPDT) 16/25 250/ /440 2,000 4, /0.5/ /0.5/ (5/5) 300 (5/5) AgNi
46 Series - Miniature industrial relays 8-16 A Features 46.52 46.61 1 & 2 Pole relay range 46.52-2 Pole 8 A 46.61-1 Pole 16 A Socket mount or direct connection via Faston connectors AC coils & DC coils
More informationScheda prodotto Relè Series B
Relè di Potenza All-or-Nothing Relays designed to meet high power switching applications with up to three changeover contacts, rated 4000 or 7500 VA - AC1. They are ideally suited for arduous duties where
More informationQuick selection table
Quick selection table Contactors... 100 to 800A Frame size 100A 15A 150A -pole Contactors s AC/DC common coil See page 46 for more details CGC-100 CGC-15 CGC-150 See page 46 for more details Ratings /
More informationSafety technique. Emergency Stop Module BH 5928, BI 5928
Safety technique Emergency Stop Module BH 5928, BI 5928 with time delay safemaster 0226419 Function diagram According to EU directive for machines 98/37/EG According to IEC/E 60 204, E 954-1 Safety category
More informationHV reed relays K-551H, K-552H K-553H, K-554H, K-555H. form A contact (normally open) for PCBs
HV reed relays K-55H, K-55H K-55H, K-55H, K-555H PIT-RADWAR S.A. 50-5 Wrocław, ul. Krakowska 6, Poland tel. (+8) 7/-65-5, fax (+8) 7/-58-59.CONTACT K-55H K-55H K-55H K-55H K-555H Switching power max W,
More informationLatch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5
3-pole DC Operated Ratings Rated Aux. Contacts Type Coil voltage 1) AC2 Current Built-in Additional 24 24V= DC 5 AC3 see 48 60V= DC 6 380V AC1 page 34 110 110V= DC 7 400V 660V 220 220V= DC 8 415V 690V
More informationScheda prodotto Relè Series E
Relè Miniatura All-or-Nothing relays ideally suited for any electronic appliances demanding very compact design and low power consumption. Design includes a protective dust cover and a completete range
More informationTime scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets
86 Series - Timer modules Features 86.00 86.30 Timer modules for use in conjunction with relay & socket. 86.00 - Multi-function & multi-voltage timer module 86.30 - Bi-function & multi-voltage timer module
More information22AF 40AF AF 150AF 225AF 400AF 800AF
Contactors MC-Series UL508 E108780 Contactor 3 Pole Standards and Certifications UL508 IEC 60947-2 & IEC 60947-4-2 CSA C22.2 No.14 Features 8 Frame Sizes 1/2HP up to 600HP @ 480V AC Screw Terminals (Lug
More informationBETA Switching Switches and Light Indicators
Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET
More informationComponents for EEx e Panels
Circuit Interrupters / Motor Switches 8006/3 8543/1 8543/2 8548/2 40 A 63 A 80 A 1 160 A 500 V 660 V 500 V 01766E00 No. of poles 12 poles Isolator features Switching capacity 400 V, AC3 11 kw 22 kw 37
More informationCircuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories
Switching & ontrols Selection Guide... 922 1V Series... 923 Dimensions... 929 Accessories... 932 ircuit Breakers Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal Blocks
More informationTechnical Information
Miniature Technical Information -09-12 Rated Insulation Voltage U i to IEC947-1 [V] 690V UL/CS [V] 600V Rated Impulse Voltage Withstand U imp [kv] 6 Rated Voltage Ue-Main Contacts C 50/60Hz [V] 230, 240,
More informationElectronic circuit breaker EBU10-T
Description The electronic circuit protector type EBU10-T (Electronic Breaker Unit) provides selective overcurrent protection in AC 230 V UPS systems. It consists of an MCB approved for short circuit interruptions
More informationMicro Contactor MA Series
Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC
More informationOrdering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays
Low-profile Relay with Various Models Low profile:.7 mm in height Clearance and creepage distance Between coil and contacts: 8 mm/8 mm Between contacts of the same polarity: 3 mm/4 mm Models with AC coil
More informationApproved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1
Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC
More informationMiniature Relay PT 2 pole 12 A, 3 pole 10 A or 4 pole 6 A DC- or AC-coil
2, 3 or 4 C/O contacts Switching performance up to 3000 VA Relay height 29 mm Cadmium-free contact material Mechanical indicator Manual test tab, optionally lockable. White marking tabs Applications Universal
More informationCircuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions...
Switching & ontrols Selection Guide... 1028 1V Series... 1029 Dimensions... 1035 www.ide.com/circuitbreaker ircuit Breakers Switches & Pilot Lights Signaling Lights Relays & Sockets Timers ontactors Terminal
More informationRUC industrial relays of small dimensions
RUC 135 with adaptor (V) Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load Min. switching current Max. inrush current Rated current
More informationPower Supplies. PS6R Series Switching Power Supplies. Expandable and space-saving switching power supplies. High efficiency reduces operation costs.
Switching Expandable and space-saving switching power supplies. High efficiency reduces operation costs. 93% efficiency Plug-in output modules for additional output voltages Plug-in branch terminal module
More informationApproved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN
Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires
More informationTeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series
Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current
More informationModel Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1
Motor Contactor J7KN Range from 4 to 500 kw (AC 3, 380/415 V) AC and DC operated Integrated auxiliary contacts; integrated aux. contact of J7KN contactors up to 11kW suitable for electronic circuits Screw
More informationUMBW-UL489 and UL1077 Listed
-UL489 and UL77 Listed Introducing the New WEG Series Thermal-Magnetic Miniature Breakers. This new offering includes both UL489 and UL77 approvals to provide a solution for circuit & equipment protection
More informationModel Number Structure
Solid State Relays (Single-phase) G3PB New Single-phase Solid State Relays with Compact Size for Heater Control Slim models with a thickness of only 22.5 mm are also available. Compact design achieved
More informationDescription. Positive safety relays
Type N & KC Positive safety Description A.C. or D.C. operated DIN rail or panel mounting 600 volt heavy duty design, A600-10 amp, Q300-5 amp Snap-on accessories available: 1 & 4 pole adder deck Pneumatic
More informationNRBM Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute
NRBM circuit breakers are the largest in rated current (A to 50A) among the IDEC circuit breakers series. These small sized, high-effi ciency breakers offer a variety of protection characteristics that
More information1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175.
SIRIUS 3RT0 3-Pole with AC Coil 3RT0* through 3RT04* 4-point AC coil can be wired on top, bottom, or diagonally. Direct mount 3RU or 3RB0 solid state overload relays to create starters. Snap-on auxiliary
More informationIndustrial Contactors CTX 3 3P 185A - 800A
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...
More informationNRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute
RA Series RA Series Key features of the RA series include: Available in 5 different styles Excellent overload and short circuit protection Small size and high-efficiency Life expectancy of over 0,000 operations
More informationPS6R 480W Switching Power Supply
ew Series PS6R 4W Switching Power Supply Reduced size and high efficiency cuts operating costs. Energy-saving 93% Efficiency Space-saving 85mm wide Efficiency (%) 96 94 92 88 86 84 82 Competitor A Competitor
More informationTechnical data. Miniature Circuit Breakers. System pro M. System pro M
Technical data System pro M System pro M 1 Prior to connection of aluminium conductors ensure that their contact points are cleaned, brushed and coated with grease. The contact terminals must be tighten
More informationRSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX
IEC-Contactor RSC 1 Features Rated operational current 9 63 (C-3) Coil voltages C 24, 230V 3 main contacts and auxiliary contact Extendable with auxiliary contact block Mounting position any 2 Description
More informationASL09..S 3-pole Contactors - Spring Terminals
4 kw 5 hp ASL09..S 3-pole Contactors - Spring DC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Low coil consumption, - Polarity on the coil
More informationxxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads
22 Series - Modular contactors 25-40 - 63 22 SERIES Features 22.32.0.xxx.1xx0 22.32.0.xxx.4xx0 25 modular contactor - 2 pole 17.5 mm wide NO contact gap 3 mm, double break Continuous duty for the coil
More informationGeneral Purpose Relay
General Purpose Relay KML 15A switching capability 1.5kV dielectric strength (between coil and contacts) Various terminals available Socket available 1 to 3 pole configurations 1. COIL DATA (at 23 ) 1)
More informationContactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload
According to CE, IEC 947, EN 60947 Contactor Catalogue 3 Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload Mini-Contactors 4kW - 5.5kW DC Contactors Mini-Relays 10A Motor Starter DOL, Star-Delta Capacitor
More informationYB2 Panel Seal. New Square Actuator Option. Series YB2. Contact No Thin Flush Mount Pushbuttons. 24mm Square Panel Seal Pushbuttons
Contact No. 182 YB2 Panel eal Thin Flush Mount Pushbuttons New quare Actuator Option 2011-01-26 www.nkk.com 1 General pecifications Electrical Capacity (Resistive Load) Power Level (silver): 3A @ 125V
More informationInstallation Contactors RIC, RAC
Installation Contactors RIC, RAC 1 Characteristics Rated operational current: 20 63 A Coil voltages: UC 24, 36, 230 V / AC 400 V Hum-free (UC versions) 2 4 contacts NC or NO Extendable with auxiliary contacts
More informationUP Series Miniature Pilot Lights
Available in Various Sizes Five illumination colors: amber, green, red, white, yellow Various sizes and design. Available with a built-in current limiting resistor. Waterproof () types available for and.
More information881WP. Type List. Ordering Information 881 WP1-1A C - - C Basic series designation 4. C -- Contact material AgNi
Type List Terminal style WP (High power type, terminals)-.0mm pitch Contact form A (SPNO) Features Low Profile mm w/ fasten terminals. High Rating 7A 277VAC. High temperature withstand up to 2. UL/CUL
More informationPCB Relay. New G8P. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC
PCB Relay Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications Compact, yet capable of switching up to 30-A loads. Complies with UL873 and UL508 column A spacings (1/8 through
More informationContact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage
35 Royal Road Flemington, NJ 08822-6000 Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage R ated load Min. switching current Max. inrush current
More informationThe full feature relay includes the combination for rotary button or plain button or light or indicator flag.
FEATURES 3A / 5A/10A of general purpose relay DPDT and 3PDT and 4PDT contact arrangement Bifurcated contact: To increase contact reliability Flag indicator: Shows relay status or power condition L.E.D.
More informationIndustrial Relay KML(1C, 2C)
Industrial Relay KML(1C, 2C) Features 1C: 15A, 2C: 10A switching capability 1.5kV dielectric strength (between coil and contacts) Various terminals available Socket available 1 & 2 poles configurations
More informationAF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts
AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up
More informationSorensen XG 1700 Series 1700 W A Watt, 1U Programmable DC Power Supplies V. Key Features. Key Modes
Sorensen XG 1700 Series 1700 W 1700 Watt, 1U Programmable DC Power Supplies 6 600 V Industry Leading Power Density Up to 1700 Watts in 1U Standard Digital Interfaces USB&RS232/485 LXI Ethernet and Isolated
More informationSection. Circuit Breakers Selection Guide...N-2. NRA Series...N-3. NRBM Series...N-13. NRC Series...
Section Selection Guide...-2 RA Series...-3 RBM Series...-3 RC Series...-20 General Instructions...-29 Internal Circuit Overview...-29 for more information on this product family visit www.idec.com/circuitbreaker
More information2 pole, 10 A AC/DC supply non polarized Plug-in for use with 94 series sockets
Miniature plug-in timers 7-10 A Plug-in timer.02-2 Pole 10 A.03-3 Pole 10 A.04-4 Pole 7 A Multifunctions Seven time scales, from 0.05 s to 100 h 94 series sockets for 35 mm rail (EN 60715) mount with push-in
More informationNRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute
RA Series RA Series RAS RA Key features of the RA series include: Available in 4 different styles Excellent overload and short circuit protection Small size and high-efficiency Life expectancy of over
More informationAF40... AF96 3-pole contactors Technical data
Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional
More informationContactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30
Contactors KNL KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30 Adaptable to various control requirements with ability of mounting from one to four additional auxiliary contacts. Versatile product capable
More informationMeta Solution. Contactors and Overload relays
Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series
More informationRSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A
Characteristics interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A Stock Code: Stock - Normally stocked in distribution facility Price*: 4.20 USD Complementary Shape of pin Jul 8, 2015 Main Commercial
More informationPCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A
PCB Relay Miniature Single-pole Relay with 80-A Surge Current and 20-A Switching Current Ideal for motor switching. Miniature, relay with high switching capacity built-in applications. Creepage distance
More informationSwitches & Pilot Devices
Key features: Two button sizes: ø29 and ø4mm ead-free, ohs compliant, (EU directive 22/95/EC) Depth behind the panel: Standard - only 27.9mm for 1 to 4 contacts Unibody - only 23.9mm for 1NC or 2NC IDEC
More informationJOSLYN CLARK VACUUM CONTACTOR FEATURES
USAVAC COPACT INTERNATIONAL AC VACUU CONTACTOR International Ratings For World Wide Applications UL Listed CSA certified 600V/660V/1000V/1500V Joslyn Clark s unique Compact AC Vacuum Contactors & Starters
More informationModular contactor for installation into distribution boards
Modular contactor for installation into distribution boards Description Modular contactors are used for installation in consumer units in dwellings, business premises, hotels, hospitals, shopping centres,
More informationTeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30
Characteristics TeSys contactors Mini-contactors TeSys LC SK and LP SK Environment Rated insulation voltage (Ui) Conforming to 0, VDE 00 gr C,BS, CSA - n, UL 0 V 0 Conforming to standards IEC 0, NF C -0,
More information22mm XW E-Stops. IEC , EN , JIS C , UL508, UL991, NFPA79, CSA C22.2 No. 14, GB
ø22mm XW E-Stops Circuit Breakers Terminal Blocks ors Timers elays & Sockets Signaling ights 22mm XW E-Stops Key features: The depth behind the panel can be as little as 46.4 mm for 1 to 4 contacts (with
More informationEmergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series
ST 50 V SEFTEST series Product description lighting Driver with self-test function For self-contained emergency lighting For modules with a forward voltage of 10 52 V SEV for output voltage < 60 V DC ow
More informationIEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101
IEC CONTACTORS Description: RT01 Contactors Are Available With Cage Clamps On The Main Terminal Connections As Well As The Auxiliary Terminal Connections. RT02, RT0 and RT04 Contactors Are Available With
More informationMounting type Contact form PCB terminals Screw terminals Quick-connect terminals
Power Relay A High-capacity, High-dielectric-strength, Multi-pole Relay Used Like a Contactor Miniature hinge for maximum switching power for motor loads as well as resistive and inductive loads. No contact
More informationAE 9... AE 40 Contactors NE... Contactor Relays
Technical data AE 9... AE 0 Contactors NE... Contactor Relays AE 9... AE 0 Contactors NE.. Contactor Relays Contents AE 9... AE 0 Contactors Description... 2 Ordering Details... 3 Technical Data... Terminal
More informationAF09... AF38 3-pole contactors 4 to 18.5 kw, AC / DC operated
AF09... AF3 3-pole contactors 4 to 1.5 kw, AC / DC operated AF09-30-10 AF09... AF3 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and 220 V DC. These contactors
More informationRUMC22F7 universal plug-in relay - Zelio RUM - 2 C/O V AC - 10 A - with LED
Characteristics universal plug-in relay - Zelio RUM - 2 C/O - 120 V AC - 10 A - with LED Product availability : Stock - Normally stocked in distribution facility Price* : 13.79 USD Main Range of product
More informationFeatures. Applications. Commercial Industrial Mining. New CBI range additional to existing range DILM7 SN10 DILM9 SN11 DILM12
GLOBAL RANGE Global Range Thermal Contactors Contactors Contactor Product Comparison Features Competitively priced Comprehensive range (AC & DC) Fitted with Auxiliary/s as standard Type coordination Applications
More informationICG Switchgear Price List 2009
ICG Switchgear Price List 2009 Section 1 Control Gear Page Contactors (AC,DC & Modular) 2,3 Overload Relays 4 Product Accessories 4,5 Starters-DOL, Star-Delta, Fan/Vibrators, Reversing/Twin 6,7 Section
More informationOrdering Information. Text PCB Power Relay G5LE
A Cubic, Single-pole 10-A Power Relay Single-pole 10A 35VDC, 0.8mm contact gap: G5LE-G Single-pole 16A 250VAC: G5LE-E ROHS compliant. Sub-miniature sugar cube relay with universal terminal footprint. Conforms
More informationB6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data
B6, B7, BC6, BC7, TBC7 - and 4-pole mini contactors VB6, VB7, VBC6, VBC7 - and 4-pole mini reversing contactors Main pole Utilization characteristics according to IEC Standards IEC/EN 60947-1, IEC/EN 60947-4-1
More informationIndustrial contactors CTX-1
87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 Industrial contactors /04/05/10/12/14/15/20/22/24/25/30/32/34/35/40/42/44/45 CONTENTS PAGE 1. Use... 1 2. Range... 1 3. Electrical
More informationD4DL. Guard Lock Safety-door Switch. Model Number Structure
Guard Lock Safety-door Switch Two new types added to series: Mechanical-lock models that lock automatically when the Operation Key is inserted, and solenoid-lock models that lock when voltage is applied
More informationEmergency lighting units EM converterled. EM converterled PRO 200 V PRO series
EM converter EM converter PRO 200 V PRO series Product description lighting Driver with DAI interface and automatic test function For self-contained emergency lighting For modules with a forward voltage
More informationCI-TI Contactors and motor starters Types CI 61 - CI 98
Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include
More informationGeneral data 5/37. Overview
General data Overview Benefits High short-circuit breaking capacity in the feeder Optimum usability in motor feeders for the special voltages 440 V, 480 V, 0 V and 690 V Compact design The are available
More informationCapacitor Switching Contactors Type K3...-A, K3...-K
Type K3...-A, K3...-K Features that matter: Patented design with significant damping on inrush-current Long-life contactors tested by FRAKO up to 100,000 switching operations Suitable for unchoked and
More informationThermal Overcurrent Circuit Breaker 3130
Thermal Overcurrent Circuit Breaker 330 Description Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting.
More informationHV reed relays K-551H, K-552H K-553H, K-554H, K-555H, K-556S form A contact (normally open) for PCBs
HV reed relays K-55H, K-55H K-55H, K-55H, K-555H, K-556S K-55H K-55H K-55H K-55H K-555H K-556S.CONTACT 0 Breakdown voltage min kv DC 7 0 7 8 9 0 Switching current max A 50 Load 5 kv DC, ma 0,5x0 6 Load
More informationModel Number Structure
Power Relay G7J Electromechanical Relays A High-capacity, High-dielectric-strength, Multi-pole Relay Used Like a Contactor Miniature hinge for maximum switching power for motor loads as well as resistive
More informationMasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy
More informationø8 A8 Series Miniature Control Units
A8 ø8 A8 Series Miniature Control Short 22-mm-long body miniature control unit series with LED illumination face and snap-action switching. Bright and clear LED illumination. All series have terminals
More informationMS25 59 MS RI RI RV 60, RV 120 RS 76 CDB3X 77 Surface Mounted (INO) and Flush Munted (IPO) Compact Distribution Boards 78
index Contents: Page New Products 4 Contactors K03, K07 Mini Contactors 10 BR6 Thermal overload relay 16 KNL6 - KNL30 Contactors 18 KNL6G - KNL30G Contactors 25 KNL40, KNL 65 Contactors 29 KNL80 - KNL110
More informationwww.ic-electronic.com Soft starter with integrated Motor Protection, Current and Voltage control Single phase controlled with internal by-pass ated operational Voltage 230VAC Frequency 45... 65Hz Self
More informationINSTALLATION AND OPERATION INSTRUCTIONS ZCP. with Domestic Hot Water (DHW) Priority
ISTAATIO AD OPEATIO ISTUCTIOS 5- Control Panel or Valve Control with Domestic Hot Water () Priority Panel ayout..................... 2 Features........................ 3 Installation.......................
More information