Contactors and Overloads MC
|
|
- Aubrey Morgan
- 5 years ago
- Views:
Transcription
1 Contactors and Overloads MC Up to 700A AC3 Up to 00A AC1 DIN rail mounting to 5A, 55kW Add on auxiliary contacts top or side mounted International approvals Designed to EN60971 Compact design for panel space saving, only mm wide upto 0A AC3 Options and ordering codes MC S Coil Voltage Series MC K3 Standard Coils Standard coils V AC, 1V AC, 30V AC, 00V AC AC3 rating Screw terminals S No auxiliaries 1 make auxiliary 1 break auxiliary 1 make 1 break auxiliary make break auxiliary 3pole contactors Standard coil voltages V /60Hz, 1V /60Hz 00V Hz, 380V Hz V DC 6mm cable terminal AC operated DC operated Main contacts AC1 690V at 0 C A AC3 A 30V kw 380/00V kw 0V kw 660/690V kw Cable crosssection Solid mm Flexible mm Cables per clamp Auxiliary contacts I th at 0 C A AC at 30V A at 00V A Coil AC operated Inrush VA Hold VA Additional aux. Front mounting: type contact blocks Side mounting: type Overload relay MCS.. MCS01.. MCS= MCS01= MCOR1.. MC1S.. MC1S01.. MC1S= MC1S01= MCOR1.. MC18S.. MC18S01.. MC18S= MC18S01= MCA/MCA01 MCAH/MCAH01 MCOR1.. MCS.. MCS01.. MCS= MCS01= MCOR1..
2 3pole contactors Standard coil voltages V /60Hz, 1V /60Hz 00V Hz, 380V Hz V DC 5mm cable terminal AC operated DC operated Main contacts AC1 690V at 0 C A AC3 A 30V kw 380/00V kw 0V kw 660/690V kw Cable crosssection Solid mm Flexible mm Cables per clamp Auxiliary contacts I th at 0 C A AC at 30V A at 00V A Coil AC operated Inrush VA Hold VA Additional aux. Front mounting: type contact blocks Side mounting: type Overload relay MCS00.. MCS00= MCAS MCOR1../MCOR.. MC3S00.. MC3S00= MCA/MCA01 MCAH/MCAH01 MCAS MCOR1../MCOR.. MC0S00.. MC0S00= MCAS MCOR.. 3pole contactors Standard coil voltages V /60Hz, 1V /60Hz 00V Hz, 380V Hz V DC 5mm cable terminal AC operated DC operated Main contacts AC1 690V at 0 C A AC3 A 30V kw 380/00V kw 0V kw 660/690V kw Cable crosssection Solid mm Flexible mm Cables per clamp Auxiliary contacts I th at 0 C A AC at 30V A at 00V A Coil AC operated Inrush VA Hold VA Additional aux. Front mounting: type contact blocks Side mounting: type Overload relay MCS00.. MCS00= MCAS MCOR3.. MC6S00.. MC6S00= MCA/MCA01 MCAH/MCAH01 MCAS MCOR3.. MC7S00.. MC7S00= MCAS MCOR3..
3 Contactors MC90 MC5 K31 K3176 K3 K3316 K30 K35 K3700 Main Contacts Ratings at AC1 0 C Amps V AC 60 C Amps AC3 60 C Amps HP kw Cable Solid mm Busbar Busbar Busbar Busbar Busbar Busbar crosssection Flexible mm x 5 x 5 x 5 30 x 5 0 x 6 x 8 Cables per clamp Auxiliary AC1 0 C Amps Contact 60 C Amps Ratings at 00V AC AC 00V Amps 30V Amps Cable Solid mm crosssection Flexible mm Cables per clamp Coil Inrush VA Hold VA Voltage range Operate Energise ms times Release ms Max. ambient Contactor C 0 to to to to +70 temperature With overload C 5 to +0 5 to to to +55 Mounting Base Base Base Base Thermal overload relays U85 U05 U80 Singlephase protection Current Current Current Product Product Product Hand reset ranges Amps ranges Amps ranges Amps Trip and alarm contacts 6090 U U U U U05 30 U U U80 80 For DC coil contactors please contact IMO for further information MC/03/03
4 Accessories Auxiliary Contacts Description Product For use with MC to MC7 Twin bifurcated for low level switching 1 make MCA Rating 690V A 1 break MCA01 00V 30V 3A Early make MCAU Maximum of per contactor Late break MCA01U For use with K31 K3175 max 1 piece 1M 1B INSIDE HKS For use with K31 K3175 max pieces 1M 1B OUTSIDE HKSA For use with K300 K33 max 3 pieces 1M 1B HKD For use with K30 K3700 max 1 piece M B HKF Rating 690V A 00V 3A Electronic Timer For use with MC to MC7 Delayon Delay timer with LED indicator 130 secs MCTA30 Repeat accuracy 1% Recovery time ms 180 secs MCTA180 Rating AC V secs MCTA600 Delayoff Max. inrush 5A min. switching 5mA 130 secs MCTB30 Delayon supply 60V AC or DC 0V AC or DC 180 secs MCTB180 Delayoff supply 60V AC, 00V AC or 00V AC secs MCTB600 Indicator For use with MC to MC7 Current indicator Green (LED) MCING 660V AC or DC (voltage drop V) Red (LED) MCINR Voltage indicator 0 V AC or DC White (Lamp) MCUN 0V AC or DC Red (LED) MCUNR Auxiliary Contacts Description Product Interface Relay For use with MC to MC7 Relay to interface with electronic circuits MCIM V 1 make contact rated 0.75A max V AC 30V DC Mechanical Interlock For use with MC to MC0 MCIW MC to MC7 MCIX K85A to K1A LG85 K31A to K3175A LG397H K300A LG398H K33A to K35A LG00H K3700A LG0H Coil Suppressor For use with MC to MC V AC/DC MCE 8V AC/DC MCE8 30V AC/DC MCE0 V AC/DC MCE380 MC to MC7 V AC/DC VGMC/ 8V AC/DC VGMC/8 30V AC/DC VGMC/ V AC/DC VGMC/ Overload Mounting For separate mounting of overloads For use with U16 With terminal USM
5 3pole contactors dimensions (mm) and weights (kg) MR07 MB09 MB Depth: 9 Weight: MCS MC1S MC18S MCS Depth: 65 Weight: MCS MC3S MC0S Depth: 87 Weight: MCS MC3S MC0S Depth: 87 Weight: MCOR1 overload (n/a MR07) MCOR1 overload MCOR overload 180 MCS MC6S MC7S Depth: 96 Weight: MC90, MC5 Overload relays MCOR1 for use with MCS tomc3s DOL Star Setting range Delta MCOR for use with MCS to MC0S Setting range DOL Star MCOR3 for use with MCS to MC7S Setting range DOL Star Delta Delta
6 Dimensions (mm) K31 to K3175A + U05 K300A + U05 U80 + K3... U80 A B C D E F G H J K +K K K K K
Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload
According to CE, IEC 947, EN 60947 Contactor Catalogue 3 Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload Mini-Contactors 4kW - 5.5kW DC Contactors Mini-Relays 10A Motor Starter DOL, Star-Delta Capacitor
More informationIEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101
IEC CONTACTORS Description: RT01 Contactors Are Available With Cage Clamps On The Main Terminal Connections As Well As The Auxiliary Terminal Connections. RT02, RT0 and RT04 Contactors Are Available With
More informationKtec Contactors and thermal overloads
Contactors and thermal overloads Techna KTEC series contactors provide a complete solution for your ac contactor requirements.the range carries TUV, UL & CSA certification, for use in Europe, North America
More information1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175.
SIRIUS 3RT0 3-Pole with AC Coil 3RT0* through 3RT04* 4-point AC coil can be wired on top, bottom, or diagonally. Direct mount 3RU or 3RB0 solid state overload relays to create starters. Snap-on auxiliary
More informationMotor Starters. Star-Delta Starters Open Type 86. Star-Delta Starters Enclosed 88 Enclosure for Star-Delta Starters 88.
Motor Starters Star-Delta Starters Open Type 86 Star-Delta Starters Enclosed 88 Enclosure for Star-Delta Starters 88 Accessories 89 Reversing Contactors 90 Pole Changing Starters 92 Technical Data 94 Wiring
More informationApproved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN
Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires
More informationCI-TI Contactors and motor starters Types CI 61 - CI 98
Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include
More informationCI-TI Contactors and Motor Starters Type CI 6-50
Data sheet CI-TI Contactors and Motor Starters CI 6-50 CI-TI contactors and motor starters provide trouble-free switching and maximum protection for costly motors and other electrical equipment. The components
More informationMotor Starting Solutions Open Type Version, in Kit Form
Motor Starting Solutions Open Version, in Kit Form Starters Protected by Manual Motor Starters Direct-On-Line Starters I> Reversing Starters I> MS... Manual motor starter MS... Manual motor starter BEA...
More informationABB s new control and protection devices
ABB s new control and protection devices One product family ABB presents a new generation of first-class specialized components: manual motor starters, contactors, overload relays and softstarters for
More informationContactors : Wide band AC / DC operated
Contactors : Wide band AC / DC operated NF / s Wide band AC / DC Operated - with Screw Terminals Description NF / include an electronic coil interface accepting a wide control voltage Uc min.... Uc max.
More informationICG Switchgear Price List 2009
ICG Switchgear Price List 2009 Section 1 Control Gear Page Contactors (AC,DC & Modular) 2,3 Overload Relays 4 Product Accessories 4,5 Starters-DOL, Star-Delta, Fan/Vibrators, Reversing/Twin 6,7 Section
More informationModel Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1
Motor Contactor J7KN Range from 4 to 500 kw (AC 3, 380/415 V) AC and DC operated Integrated auxiliary contacts; integrated aux. contact of J7KN contactors up to 11kW suitable for electronic circuits Screw
More informationEssential equipment for all your requirements
NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides
More informationIndustrial contactors CTX-1
87045 LIMOGES Cedex Telephone number: +33 5 55 06 87 87 Fax: +33 5 55 06 88 88 Industrial contactors /04/05/10/12/14/15/20/22/24/25/30/32/34/35/40/42/44/45 CONTENTS PAGE 1. Use... 1 2. Range... 1 3. Electrical
More informationCI-tronic Soft Start Motor Controller Type MCI 25B with Brake
Data sheet CI-tronic Soft Start Motor Controller Type MCI 25B with Brake MCI 25B motor controller with brake is designed for soft starting and braking of 3 phase AC motors. The digital controlled soft
More informationIndex. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.
Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv
More informationQuick selection table
Quick selection table Contactors... 100 to 800A Frame size 100A 15A 150A -pole Contactors s AC/DC common coil See page 46 for more details CGC-100 CGC-15 CGC-150 See page 46 for more details Ratings /
More informationMotors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line
Motors Automation Energy Transmission & Distribution Coatings Automation Contactors - CWM Line 2 Contactores Compactos CWC0 Contactors - CWM Line Sumary Presentation Accessories Overview 5 Three-Pole Contactors
More informationLatch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5
3-pole DC Operated Ratings Rated Aux. Contacts Type Coil voltage 1) AC2 Current Built-in Additional 24 24V= DC 5 AC3 see 48 60V= DC 6 380V AC1 page 34 110 110V= DC 7 400V 660V 220 220V= DC 8 415V 690V
More informationData sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443
CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O December 2002 DKACT.PD.C50.G2.02 520B1443 2 DKACT.PD.C50.G2.02 Danfoss A/S 12-2002 Introduction The MCI soft starters
More informationAF09... AF38 3-pole contactors 4 to 18.5 kw, AC / DC operated
AF09... AF3 3-pole contactors 4 to 1.5 kw, AC / DC operated AF09-30-10 AF09... AF3 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and 220 V DC. These contactors
More information22AF 40AF AF 150AF 225AF 400AF 800AF
Contactors MC-Series UL508 E108780 Contactor 3 Pole Standards and Certifications UL508 IEC 60947-2 & IEC 60947-4-2 CSA C22.2 No.14 Features 8 Frame Sizes 1/2HP up to 600HP @ 480V AC Screw Terminals (Lug
More informationApproved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1
Mini Motor Contactor J7KNA ) Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN-rail) Range from 4 to 5.5 (AC 3, 380/415V) 4 -main pole version (4 AC
More informationMeta Solution. Contactors and Overload relays
Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series
More information4 - Miniature controls
Index -....1.22 Selection Contactors for connection to PLCs, B6S & B7S, 3 phase...6 Contactors, Interface, B6 & B7, 3 phase...5 Contactors, features...1 Contactors, mechanically interlocked, B6 & B7, 3
More informationD509E. Manual Motor - Starters
D509E Manual Motor - Starters Index Page Manual Motors Starters 182 Auxilliary Contact Blocks 182 Trip Alarm Aux. Switch 182 Shunt Release 182 Under-voltage Release 183 Accessories 183 Busbar Connectors
More informationTime scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)
86 Timer modules 86 Timer modules for use in conjunction with relay & socket. 86.00T - Multi-function & multi-voltage timer module 86.30T - Bi-function & multi-voltage timer module Complies with EN 45545-2:2013
More informationMini Contactors CI 4-
Data sheet Mini Contactors CI 4- Introduction CI 4 minicontactors cover the power range 1.5 to 5.9 kw and are available for a.c. and d.c. coil voltages. Characteristic of the minicontactors is that they
More informationCI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O
Data sheet CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O The MCI soft starters are designed for soft starting and stopping of 3 phase AC motors, thus
More informationACS motor protection circuit breakers KT 7 Introduction
Introduction Automatic Type 2 coordination The right circuit breaker for all applications The KT 7 circuit breaker family consists of two basic frame sizes of mm and 5 mm in three variations with different
More informationSeries Motor Protection
320-327 Series Motor Protection Relay Physical Address: 298 Soutter Street, Pretoria West Tel: 083 454 6949, +27 12 327 1729 Fax: +27 (0)12 327 1733 Toll Assist: 0860 10 30 41 www.newelec.co.za sales@newelec.co.za
More informationPanorama. Contactors Motor protection Accessories
Panorama Contactors Motor protection Accessories Extensive range of contactors High performance contactors for your applications from 9 to 5000 A Mini contactors for compact equipments - up to 5.5 kw /
More informationApproved Standards. Ordering Information. Thermal Overload Relay J7TKN. Model Number Legend. Thermal Overload Relay. Accessories
Thermal Overload Relay J7TKN ) Thermal Overload Relay Direct and separate mounting Single phasing sensivity according to IEC 60947-4-1 Finger proof (BGV A2) Accessories Set for single mounting Approved
More informationLow voltage switch gear
Low voltage switch gear Omron is an established global manufacturer of low voltage switch gear (LVSG) products, and the company s new series (J7) complements the existing portfolio. High power-handling
More informationCI-TI TM Contactors and Motor Starters Contactors CI 6-50
Data sheet CI-TI TM Contactors and Motor Starters Contactors CI 6-50 Description Danfoss contactors CI 6-50 cover the power range 2.2-25 kw. CI 6 is built up as a combined contactor/control relay. CI 9
More informationComponents for EEx e Panels
Circuit Interrupters / Motor Switches 8006/3 8543/1 8543/2 8548/2 40 A 63 A 80 A 1 160 A 500 V 660 V 500 V 01766E00 No. of poles 12 poles Isolator features Switching capacity 400 V, AC3 11 kw 22 kw 37
More informationMicro Contactor MA Series
Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC
More informationControls. CONTACTORS CWB Line (up to 40A)
Controls CONTACTORS CWB Line (up to 40A) 0800 367 934 Contactors CWB Line (up to 40A) CONTACTORS CWB Line (up to 40A) Summary New WEG CWB Contactors 4 The Technology Within 6 Energy Savings 7 Easy Panel
More informationTime scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets
86 Series - Timer modules Features 86.00 86.30 Timer modules for use in conjunction with relay & socket. 86.00 - Multi-function & multi-voltage timer module 86.30 - Bi-function & multi-voltage timer module
More informationMAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-
MKING MODERN LIVING POSSIBLE Technical brochure Minicontactors CI 5- www.danfoss.com 2 IC.PD.C10.F3.02-520B4167 Danfoss /S, C-SMC, mr, 07-2010 Contents Page Minicontactor CI 5- Introduction...............................................................................4
More informationShort form catalogue. Motor protection & control
Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59
More informationMotor Protection Circuit Breakers
Motor Protection Circuit Breakers About us Larsen & Toubro is a technologydriven USD 9.8 billion company that infuses engineering with imagination. The Company offers a wide range of advanced solutions
More informationContactors Motor-Starters D677E121
Contactors Motor-Starters D677E121 Index Page General 2 Approvals 3 Technical Information 5 Mounting Information 6 Mini Contactors 7 Mini Contactors 8 Interface Contactors 8 Mini Reversing Contactors 14
More informationEW series Industrial contactors
2012_EW_Contactors_bro_EN.qxd:Mise en page 1 31/08/12 10:24 Page 2 EW series Industrial contactors Hager offers a complete range of contactors for commercial market such as buildings, infrastructures,
More informationMeta Solution. Contactors and Overload relays
Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series
More informationEnclosed motor starters
Direct-on-line starters Without thermal overload relay (1) Direct-on-line starters Composite steel/plastic enclosure. Ingress protection: IP 65 Maximum Maximum kw rating Control Reference Weight current
More informationAbout us. Switchgear Factory, Mumbai
About us Larsen & Toubro is a technologydriven USD 8.5 billion company that infuses engineering with imagination. The Company offers a wide range of advanced solutions in the field of Engineering, Construction,
More informationContactor Types CI 61-98
MKING MODERN LIVING POSSIBLE Data sheet Contactor s CI 6-98 Contactors CI 6, CI 73, CI 86 and CI 98 switch powers of up to 30 kw, 37 kw, 45 kw and 55 kw respectively under 3 380 V C-3 loads. ccessories
More informationAF40... AF96 3-pole contactors Technical data
Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional
More informationTechnical Section: Miniature Circuit Breakers
MCBs and Accessories Data. Calibration With CBI Hydraulic- Magnetic Miniature Circuit Breakers, there is no effect on the fixed trip point at ambient temperature ranges from -5 C to +60 C. 2. Products
More informationJOSLYN CLARK VACUUM CONTACTOR FEATURES
USAVAC COPACT INTERNATIONAL AC VACUU CONTACTOR International Ratings For World Wide Applications UL Listed CSA certified 600V/660V/1000V/1500V Joslyn Clark s unique Compact AC Vacuum Contactors & Starters
More informationFMotor Circuit Controllers
Technical Information Motor Circuit Controller IEC Performance Data Catalog Number KTA7-25S...32S 0.16A 0.25A 0.4A 0.63A 1A 1.6A 2.5A 4A 6.3A 10A 16A 20A 25A 29A 32A Rated Operational Current, I e [A]
More informationMotor Protection Circuit Breakers 3VU13 and 3VU16
Motor Protection Circuit Breakers 3VU13 and 3VU16 3VU13/3VU16 is suitable for use in fuseless motor feeders upto 11KW/22KW (25A/63A) respectively. 3VU motor protection circuit breakers are used for protection
More informationREVISED ATM72 Auto Transfer Module
Capricorn Controls DA01ATM1-1 Data & Application Note Page 1 of 8 REVISED - - - ATM72 Auto Transfer Module Genset Controls - Timers - Monitors - Trips - Battery Charging - Spares & Accessories - Custom
More informationSwitchgear for Railway Applications
Selection Guide Contactors Contactor Relays Motor Protection Circuit Breakers Circuit Breakers Bimetallic Overload Relays Electric Switchgear for Rolling Stock Application What s Inside Topic Page Topic
More informationTechnical Information
Technical Information KT7 Controller Time-Current Characteristic KT7 Manual Motor Starter/Protector 1. Thermal Release Trip Current The adjustable current-dependent delayed bimetal release protects motors
More informationUMBW-UL489 and UL1077 Listed
-UL489 and UL77 Listed Introducing the New WEG Series Thermal-Magnetic Miniature Breakers. This new offering includes both UL489 and UL77 approvals to provide a solution for circuit & equipment protection
More informationBulletin 825 SMM Smart Motor Manager
Bulletin 825 SMM Smart Motor Manager Your order must include: Cat. no. of the Smart Motor Manager selected with supply Voltage Suffix Code, Cat. no. of Converter Module selected, and, If required, Cat.
More informationFeatures. Applications. Commercial Industrial Mining. New CBI range additional to existing range DILM7 SN10 DILM9 SN11 DILM12
GLOBAL RANGE Global Range Thermal Contactors Contactors Contactor Product Comparison Features Competitively priced Comprehensive range (AC & DC) Fitted with Auxiliary/s as standard Type coordination Applications
More informationTeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series
Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current
More informationVB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated
VB6, VB7 -pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB7-0-10 2CDC211006F0011 Description VB6, VB7 -pole compact design reversing contactors are space optimized control
More informationmax pole for t=15 ms
Types RI 61 RI 61N RI 61J RI 62 RI 62J RI 63 RI 63N RI 64 single-pole single-pole + neutral pole single-pole (for DC circuits) two-pole two-pole (for DC circuits) three-pole three-pole + neutral pole three-pole
More informationNEMA Contactors & Starters (Freedom)
Page 1 February, 1 Supersedes TIP AN1, AN, CN1, CN Pages 1-0, Dated 1/1/4 ECN01, ECN0, ECN0, ECN0, ECN0 AN1, AN, CN1 & CN Sizes 00-, 00V Max. Non-Reversing & Reversing NEMA Type Enclosures 1, R, 4X & 1
More informationGLOBAL RANGE. Global Range Motor Control. Contactors. Features. Applications. Overload Relays. Features. Applications. Manual Motor Starter Features
GLOBAL RANGE Contactors Overload Relays Features Competitively priced Comprehensive range (AC & DC) Fitted with Auxiliary/s as standard Type coordination Applications Commercial Industrial Mining Features
More informationB6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data
B6, B7, BC6, BC7, TBC7 - and 4-pole mini contactors VB6, VB7, VBC6, VBC7 - and 4-pole mini reversing contactors Main pole Utilization characteristics according to IEC Standards IEC/EN 60947-1, IEC/EN 60947-4-1
More informationOSS - TN, TBN Type. Information to Order. Features. External View ATS(60~600A) OSS P- A B C D. Rated Current. D Operating Voltage
Information to Order A Rated Current 06 1 60A 100A 2 4 400A 6 600A B Type TN : TN-Type TBN : TBN-Type C Number of Poles 2 : 2P 3 : 3P 4 : 4P OSS - 6 - - P- A B C D D Operating Voltage A1 : AC 110V A2 :
More informationInstallation Contactors RIC, RAC
Installation Contactors RIC, RAC 1 Characteristics Rated operational current: 20 63 A Coil voltages: UC 24, 36, 230 V / AC 400 V Hum-free (UC versions) 2 4 contacts NC or NO Extendable with auxiliary contacts
More informationIndustrial Contactors CTX 3 3P 185A - 800A
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...
More informationThe breakers offer thermal-magnetic trip protection according to Z and K characteristics.
Series High Performance Circuit Breakers Description The high performance MCB offers a compact solution to circuit protection. The devices are DIN rail mounted. The is available with application-specific
More informationASL09..S 3-pole Contactors - Spring Terminals
4 kw 5 hp ASL09..S 3-pole Contactors - Spring DC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Low coil consumption, - Polarity on the coil
More informationLow Voltage Industrial Controls. CWB and RW27-2D. IEC Contactors and Thermal Overload Relays
CWB and RW27-2D IEC Contactors and Thermal Overload Contactors Overload A-2-800-ASK4WEG www.weg.net/us Contactors CWB CWB Features A-4 Catalog Number Format A-7 Accessories Overview A-8 Part Number List
More informationStar Series Motor protection & control
Contact us ABB Inc. Low Voltage Control Products 16250 W. Glendale Drive New Berlin, WI 53151 Phone: 888-385-1221 Fax: 800-726-41 USA Technical support & Customer Service: 888-385-1221, Option 4 7:30AM
More informationBulletin 100-D IEC Contactors
Bulletin 100-D IEC Contactors Electronic and conventional coils AC & DC Integrated PLC interface Low power pick-up & hold-in Wide voltage ranges Complete range of accessories Environmentally friendly Compact
More informationEquipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module
transformers and buzzers and bells socket outlets and special supports 042 25 042 52 041 07 042 80 042 85 Pack Cat.Nos Bell transformers dconform to IEC / EN 61558-2-8 Protected against overloads and short
More informationShort form catalogue Motor protection and control Block contactors and overload relays
Short form catalogue Motor protection and control Block contactors and overload relays Motor rated operational powers and currents The currents given below concern standard three-phase four-pole cage motors
More informationManual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X
Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and
More informationManual Motor Starters. Meta-MEC
Manual Motor Starters Meta-MEC Manual Motor Starters LS Meta-MEC Manual Motor Starters provide completed ranges up to 100A 45 mm 55 mm 32AF 2 2 45 mm 70 mm 63AF 100AF 3 3 Manual LS Meta-MEC Motor Starters
More informationMCS MINIATURE CONTACTORS SELECTION GUIDE THE MINIATURE MODULAR CONTROL SYSTEM SMALL IN DIMENSIONS - BIG IN PERFORMANCE
MCS MINIATURE CONTACTORS SELECTION GUIDE THE MINIATURE MODULAR CONTROL SYSTEM SMALL IN DIMENSIONS - BIG IN PERFORMANCE DOL-Starter Overload Protection PROTECTION FOR AC AND DC MOTORS The Bulletin 193-K
More informationMeta Solution. Contactors and Overload relays
Meta Solution Contactors and Overload relays New generation of Contactors from LS Industrial Systems Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol
More informationMS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories
Page 1 of 5 MS132-10 ABB contact for United States of America General Information Extended Product Type: Product ID: EAN: Catalog Description: Long Description: MS132-10 1SAM350000R1010 4013614400100 MS132-10
More informationSelection Guide Motor Control Device Solutions
Selection Guide Motor Control Device Solutions Expect more and get it from c3controls. Our portfolio of Motor Control Devices consists of worldclass products designed and manufactured to meet your requirements
More informationAF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts
AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up
More informationKD LV Motor Protection Relay
1. Protection Features KD LV Motor Protection Relay Overload (for both cyclic and sustained overload conditions) Locked rotor by vectorial stall Running stall / jam Single phasing / Unbalance Earth leakage
More informationTechnical data. Miniature Circuit Breakers. System pro M. System pro M
Technical data System pro M System pro M 1 Prior to connection of aluminium conductors ensure that their contact points are cleaned, brushed and coated with grease. The contact terminals must be tighten
More informationPartnership that you can trust. LV Switchgear Motor Control Products.
s Partnership that you can trust LV Switchgear Motor Control Products Maximum etail Price w.e.f. st October, 204 www.siemens.co.in s SIMOCODE pro S Get your motor control center s intelligent and compact
More information2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4
CHAPTER ELECTRICAL 2 INSTALLATION Contents of this Chapter... 2.1 Warnings & Agency Approvals..................2 2 2.1.1 Isolation..............................................2 2 2.1.2 Electrical Power
More informationMotor Circuit Breakers C4
Motor protection rating up to 100 Amps Short circuit breaking capacity up to 100kA Phase failure protection DIN rail mounting Wide range of accessories Options and ordering codes Model C4/32T Setting Short
More informationAF series contactors (9 2650)
R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00
More informationEnclosed Starters. Contents. Motor nominal powers and current... 20/2. Panorama... 20/3. Starting of three-phase asynchronous motors...
Enclosed Starters 20 Contents Motor nominal powers and current... 20/2 Panorama... 20/3 Starting of three-phase asynchronous motors... 20/4 Ordering Details Enclosed D.O.L starters - Protection by thermal
More informationTechnical Information
Miniature Technical Information -09-12 Rated Insulation Voltage U i to IEC947-1 [V] 690V UL/CS [V] 600V Rated Impulse Voltage Withstand U imp [kv] 6 Rated Voltage Ue-Main Contacts C 50/60Hz [V] 230, 240,
More informationDEVICE STATE/BYPASSED FAILURE OVERLOAD
Technical specifications Type 5. 7. Control electronics Rated values Terminal Rated control supply voltage A1A2 V AC 115 230 115 230 Tolerance % -15+10-15+10 Rated control supply STANDBY ma 15 15 Rated
More informationContactors. d 3-pole contactors for motor control, 9 to 95 A Utilisation category AC-3 Control circuit : a.c. References
d 3-pole contactors for motor control, 9 to 95 A Utilisation category AC-3 Control circuit : a.c. c Standard power ratings Rated Instantaneous Basic reference. Weight of 3-phase motors operational auxiliary
More informationGeneral Catalogue. Quality made in D946E173
General Catalogue Quality made in D946E173 Index Page Contactors, Motor-Starter (D677E) 3 Micro Contactors 9 Mini Contactors 19 Contactor Relays 33 Contactors 39 Starters 85 D.O.L. Starters 105 Overload
More informationAF series contactors (9 2650)
R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00
More informationContactors and Overload Relays
Contactors and Overload Relays Catalogue 2011 2 CONTENT Contactor Introduction...4 Range over view...8 Technical information - CN Series...10 Add on accessories - CN Series...12 Accessory fitment over
More informationMotor Applications Automation. Command and Signalling Power Management Product Overview for Machinery
Motor Applications Automation Command and Signalling Power Management Product Overview for Machinery Motor-Protective Circuit-Breakers PKZ and PKE Flexible Solutions: Simple, Intelligent, Pluggable, Versatile
More informationAF09... AF30 3-pole Contactors up to 20 HP / 480 VAC
AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory
More informationContactors & Overload relays
Contactors & Overload relays Metasol MC 3P 18 to 100 MC type Magnetic Contactors Frame size screws clamp terminals Number of poles Rated operational voltage, Ue Rated insulation voltage, Ui Rated frequency
More informationModular contactors and relays
pages /4 to / pages /8 and /9 pages /10 and /11 pages /12 and /13 Presentation and standards Presentation Designed for use in modular panels and enclosures, these contactors feature : i Easy installation
More information