Item Parameter Value. 1. Rated operating voltage 123 [kv] 245 [kv] 420 [kv] 2500 [A] 3150 [A] 4000 [A] 2500 [A] 3150 [A] 4000 [A]

Size: px
Start display at page:

Download "Item Parameter Value. 1. Rated operating voltage 123 [kv] 245 [kv] 420 [kv] 2500 [A] 3150 [A] 4000 [A] 2500 [A] 3150 [A] 4000 [A]"

Transcription

1

2

3

4 Item Parameter Value 1. Rated operating voltage 13 [kv] 45 [kv] 40 [kv]. Rated continuous current 500 [] 3150 [] 4000 [] 500 [] 3150 [] 4000 [] 500 [] 3150 [] 4000 [] 3. Peak current 160 [k] 160 [k] 160 [k] 4. Shortcircuit current, 1 sec. 63 [k] 63 [k] 63 [k] Test voltage (50 Hz): earth and pole to pole insulation contact to contact insulation Surge test voltage: earth and pole to pole insulation contact to contact insulation Operational rated surge test voltage: earth insulation contact to contact insulation 30 [kv] 65 [kv] 550 [kv] 630 [kv] 460 [kv] 530 [kv] 1050 [kv] 100 [kv] 50 [kv] 610 [kv] 145 [kv] 145 (+40)* [kv] 1050 [kv] 900 (+345)* [kv] 8. Radio interference voltage <500 [uv] <500 [uv] <500 [uv] 9. Mechanical strength 000 cycles 000 cycles 000 cycles 10. Motor operating mechanism NSO80 NSO80 NSO80 Rated operating Dimensions () voltage [kv] C D D C

5 o50 D E (1100) C 16.5 o50 45 D K F G 80 J (1100) C G 80 K F J Z 1400 Z NSO Z 1400 Z NSO80 Item Parameter Value 1. Rated voltage 13 [kv] 170 [kv] 45 [kv] 40 [kv]. Rated continuous current 00 [] 500 [] 4000 [] 00 [] 3150 [] 4000 [] 500 [] 3150 [] 4000 [] 500 [] 3150 [] 4000 [] 3. Rated peak withstand current 100 [k] 100/160 [k] 160 [k] 160 [k] 4. Rated shortcircuit withstand current 40 [k] 40/63 [k] Rated powerfrequency withstand voltage: to earth across open disconnector Rated lighting impulse withstand voltage: to earth across open disconnector Rated switching impulse withstand voltage: to earth across open disconnector 30 [kv] 65 [kv] 550 [kv] 630 [kv] 35 [kv] 375 [kv] 750 [kv] 860 [kv] 63 [k] t=3s 460 [kv] 530 [kv] 1050 [kv] 100 [kv] 63 [k] t=3s 50 [kv] 610 [kv] 145 [kv] 1665 [kv] 1050 [kv] 145 [kv] Type Rated voltage [kv] Fig Dimensions () C D E F G J K TFPK TFPK TFPK TFP TFP TFP TFP

6 Item Parameter Value 1. Rated operating voltage 7,5 [kv] 13 [kv] 145 [kv] 45 [kv]. Rated continuous current 1600 [] 500 [] 3150 [] 4000 [] 1600 [] 500 [] 3150 [] 4000 [] 1600 [] 500 [] 3150 [] 4000 [] 1600 [] 500 [] 3150 [] 4000 [] 3. Peak current 15 [k] 15 [k] 15 [k] 15 [k] 4. Shortcircuit current, 1 sec. 50 [k] 50 [k] 50 [k] 50 [k] 5. Test voltage (50 Hz): earth and pole to pole insulation contact to contact insulation 140 [kv] 160 [kv] 30 [kv] 65 [kv] 75 [kv] 315 [kv] 460 [kv] 530 [kv] 6. Surge test voltage: earth and pole to pole insulation contact to contact insulation 35 [kv] 375 [kv] 550 [kv] 630 [kv] 650 [kv] 750 [kv] 1050 [kv] 100 [kv] 7. Radio interference voltage <1000 [µv] <1000 [µv] <1000 [µv] <100 [µv] 8. Mechanical strength 000 cycles 000 cycles 000 cycles 000 cycles 9. Operating mechanisms: motor manual NSO80 NR5 NSO80 NR5 NSO80 NR5 NSO80 NR5 G Type Dimensions () G ONIII ONIII ONIII ONIII

7 E/F D C Type Dimensions () C D E F ONIII ONIII ONIII ONIII

8 min min C D Item Parameter Value 1. Rated operating voltage 7,5 [kv] 13 [kv] 145 [kv] 45 [kv]. Peak current 15 [k] 15 [k] 15 [k] 15 [k] 3. Shortcircuit current, 1 sec. 50 [k] 50 [k] 50 [k] 50 [k] 4. Test voltage (50 Hz) for insulation 140 [kv] 30 [kv] 75 [kv] 530 [kv] 5. Surge test voltage for insulation 35 [kv] 550 [kv] 650 [kv] 1050 [kv] 6. Radio interference voltage <1000 [µv] <1000 [µv] <1000 [µv] <100 [µv] 7. Mechanical strength 000 cycles 000 cycles 000 cycles 000 cycles 8. Operating mechanisms: motor manual NSO80 NR5 NSO80 NR5 NSO80 NR5 NSO80 NR5 Type Dimensions () C D UNIII UNIII UNIII UNIII

9 Item Parameter Value 1. Rated voltage / rated current squirrel cage motor series motor contactor coil of motor supply voltage control (depending on motor rated voltage). contactor coil. 3. heater electromagnetic lock Rated power: squirrel cage motor series motor contactor coil heater electromagnetic lock coil Shaft torque: rated maximum 4 3x400 [VC] / 4,5 [] 0 [VDC] / 4 [] 110 [VDC] / 10 [] 400 [VC] 0 [VDC] 110 [VDC] 0 [VDC] 30 [VC] 110 [VDC] 110 [VC] 30 [VC] 0 [VDC] 110 [VDC] 0 [VDC] 110 [VDC] 750 [W] 500 [W] 7 [W] 5 [W] 7 [W] 300/500/1000 [Nm] 500/800/1600 [Nm] 4. HV switching time 7/11/16 [s] 5. Crank handle speed ca Main shaft angular displacement 90/15/19 [ 0 ] 7. Rated switching capability of control switch C15; 30 [V];,5 [] DC13; 0 [V]; 0,5 [] 8. Maximum conductor cross section 4 [ ] 9. Enclosure protection rating IP Rated mechanical strength 000 cycles M max

10 Item Parameter Value 1. Rated torque 300 [Nm]. 3. Rated voltage: electromagnetic lock heater Rated power: electromagnet coil DC / C start electromagnet coil DC / C operation heater 30 [VC] 0 [VDC] 110 [VDC] 30 [VC] 0 [VDC] 110 [VDC] 0 [W] / 700 [W] 1,5 [W] / 1,5 [W] 5 [W] 4. Main shaft angular displacement 19 [ 0 ] 5. Rated switching capability of control switch C15; 30 [V];,5 [] DC13; 0 [V]; 0,5 [] 6. Maximum conductor cross section 4 [ ] 7. Enclosure protection rating IP Rated mechanical strength 000 cycles M DP9

11

12 Item Parameter with arcing contact Value 1. Rated voltage 4 [kv]. Rated continuous current 630 [] 3. Rated frequency 50 [Hz] Lightning surge test voltage: earth and pole to pole insulation contact to contact insulation Rated alternating test voltage: earth and pole to pole insulation contact to contact insulation Rated current: low inductive reactance circuit in ring network circuits in cable and overhead lines, idle state 0 [] 10 [] 0 [] 15 [kv] 145 [kv] 50 [kv] 60 [kv] 7. Rated peak current 40 [k] 8. Rated shortcircuit current, 1 sec. 16 [k] 9. Mechanical strength 1000 cycles with air breaking chamber 5 [] 630 [] 630 []

13 Item Parameter Value 1. Disconnector type ONIIIS4 ONIIIS36. Rated continuous disconnector current 800 [] 1600 [] 000 [] 800 [] 1600 [] 3. Rated peak disconnector current 50 [k] 80 [k] 100 [k] 50 [k] 4. Shortcircuit disconnector current, 1 sec. 0 [k] 31,5 [k] 40 [k] 0 [k] Test voltage (50 Hz): earth and pole to pole insulation contact to contact insulation Surge test voltage: earth and pole to pole insulation contact to contact insulation Earth insulation creepage distance: rated increased 55 [kv] 75 [kv] 15 [kv] 145 [kv] 55 [kv] 75 [kv] 15 [kv] 145 [kv] 40 [] 460 [] 55 [kv] 75 [kv] 15 [kv] 145 [kv] 75 [kv] 100 [kv] 170 [kv] 195 [kv] 630 [] 770 [] 900 [] 1116 [] 8. Earthing switch peak rated current 40 [k] 80 [k] 80 [k] 40 [k] 9. Earthing switch shortcircuit current, 1 sec. 16 [k] 31,5 [k] 31,5 [k] 16 [k] 10. Rated mechanical strength 000 cycles 000 cycles 11. Operating mechanism: motor manual NSL60 NNP NSL60 NNP o18 Disconnector type F Dimensions [] C C C D E F ONIIIS4/8/U ONIIIS36/8/U D E

14 Item Parameter Value 1. Motor rated voltage 4 [VDC] 110 [VDC] 0 [VDC] 30 [VC]. Rated power 300 [W] 3. Motor rated current 19 [] 4 [], [] 4. Maximum axial force 6,5 [kn] 5. Switching time ca. 4 sek. 6. Max. conductor crosssection for connection of terminal strip,5 [ ] 7. Rated mechanical strength cycles 7 48 x M

15 Item Parameter Value 1. Rated torque 300 [N]. 3. Rated voltage: electromagnetic lock Rated power: elektromagnet coil DC/C start elektromagnet coil DC/c operation 0 [VDC] 30 [VC] 110 [VDC] 0 [W] / 700 [W] 1,5 [W] / 1,5 [W] 4. Main shaft angular displacement 19 [ 0 ] 5. Rated switching capability of control switch C15; 30 [V];,5 [] DC13; 0 [V]; 0,5 [] DC13; 110 [V]; 1 [] 6. Maximum conductor cross section 4 [ ] 7. Enclosure protection rating IP Rated mechanical strength 000 cycles ~ ~

16

17 Item U r kv I sc kv I ma kv PM* Type I r (complements order number) ,1 3, H5 11 3H H5 1 3H U p = 75 kv U d = 8 kv H5 13 3H H5 14 3H , H ,5 U p = 95 kv U d = 38 kv H5 04 3H , H H5 7 3H U p = 15 kv U d = 50 kv H5 73 3H H5 74 3H U p = 170 kv U d = 70 kv H H

18 (558) C (57) kv I sc k I r a PM* 160 [] b c Ciężar kg a PM* 10 [] 13,1 do 16 do do do 50 0 do 5 do do do 50 31, , ,5 kv I sc k I r a PM* 160 [] b c b c PM* 10 [] 5 do do do 50 31,5 do do 50 5 do 31, Ciężar kg a b c Ciężar kg Ciężar kg 4 kv I sc k I r a PM* 10 [] b c Ciężar kg a PM* 75 [] b c Ciężar kg 16 do 5 do do do 70 0 do do do kv I sc k I r a PM* 350 [] b c Ciężar kg 16 do 5 do do do 110 C (558) (68) C C

19 Lp. Parameter Value OM/OM1 OM/OM4 1. Rated operating voltage 1 [kv] 4 [kv]. Rated frequency 50 [Hz] 50 [Hz] 3. Rated continuous current 630 [] 630 [] 4. Rated transitive current 700 [] 1000 [] 5. Work switching capabilities: low inductance circuit ring network circuits cable and overhead line loading 630 [] 630 [] 50 [] 630 [] 630 [] 5 [] 6. Maximum fuse cartridge size 100 [] 1 63 [] 7. Rated shortcircuit making current 50 [k] 40 [k] 8. Peak withstand current 50 [k] 50 [k] 9. Shortcircuit withstand current, 1 sec. 0 [k] 0 [k] 10. Test voltage (50 Hz): earth and pole to pole insulation terminal to terminal insulation 8 [kv] 3 [kv] 50 [kv] 60 [kv] 11. Surge test voltage: earth and pole to pole insulation terminal to terminal insulation 75 [kv] 85 [kv] 15 [kv] 145 [kv] 1. Mechanical strength 000 cycles 000 cycles

20 I I G G F F ~ D D C C H E min R H E min R Switch disconnector type Dimensions [] OM1/UD/UG/15/ LO PO 15 OM1/UD/UG/185/ LO PO 185 OM4/UD/UG/160/ LO PO 160 OM4/UD/UG/75/ LO PO C D E 114* 170* F G * Switch disconnector type OM1/D/UD/15/ LO PO H I R Possibility of reducing the dimensions Dimensions [] 15 OM1/D/UD/185/ LO PO 185 OM4/D/UD/160/ LO PO 160 OM4/D/UD/75/ LO PO C D E 114* 170* 170 F G H I R Switch disconnector type C D E F G H I OM1/T/UD/UG/15/ LP PP * 100* * 90* * Switch disconnector type C D E F G H I R OM1/T/DT/UD/15/ LP PP * 100* OM4/T/DT/UD/160/ LP PP * 90* I F ~900 G F G D C E H min R Possibility of reducing the dimensions Dimensions [] I R OM4/T/UD/UG/160/ LP PP Dimensions [] D C E H min R

21 X C3 C C3 3 C1 Item Parameter Value 1. Rated operating voltage 1 [kv] 1 [kv] 1 [kv] 1 [kv] 17,5 [kv] 17,5 [kv] 4 [kv] 4 [kv] 36 [kv]. Rated continuous current 800 [] 1600 [] 1600 [] 000 [] 800 [] 1600 [] 800 [] 1600 [] 1600 [] 3. Peak current 80 [k] 80 [k] 100 [k] 100 [k] 50 [k] 63 [k] 40 [k] 80 [k] 80 [k] 4. Shortcircuit current Test voltage (50Hz): earth and pole to pole insulation terminal to terminal insulation Surge test voltage: earth and pole to pole insulation terminal to terminal insulation Pole pitch: air insulation air insulation with additional insulating barrier 1 sec. 40 [k] 40 [k] 0 [k] 5 [k] 16 [k] 31,5 [k] 31,5 [k] 3 sec. 31,5 [k] 31,5 [k] 8 [kv] 3 [kv] 75 [kv] 85 [kv] 00 [] 15 [] 8 [kv] 3 [kv] 75 [kv] 85 [kv] 180 [] 8 [kv] 3 [kv] 75 [kv] 85 [kv] 180 [] 8 [kv] 3 [kv] 75 [kv] 85 [kv] 10 [] 38 [kv] 45 [kv] 95 [kv] 110 [kv] 160 [] 38 [kv] 45 [kv] 95 [kv] 110 [kv] 180 [] 50 [kv] 60 [kv] 15 [kv] 145 [kv] 75 [] 160 [] 50 [kv] 60 [kv] 15 [kv] 145 [kv] 75 [] 95 [kv] 10 [kv] 190 [kv] 0 [kv] 390 [] Disconnector type OW1/8/Z/15 (with insulating barriers) OW1/8/Z/UG/15 (with insulating barriers) OW1/8/Z/UD/15 (with insulating barriers) Dimensions [] C1 C C OW1/8/Z/ OW1/8/Z/UG/ OW1/8/Z/UD/ OW17/8/Z/ OW4/8/Z/160 (with insulating barriers) OW4/8/Z/UG/160 (with insulating barriers) OW4/8/Z/UD/160 (with insulating barriers) OW4/8/Z/ OW4/8/Z/UG/ OW4/8/Z/UD/

22 X C3 C C1 C3 X C3 C C1 C3 1 Disconnector type Dimensions [] C1 C C3 OW1/16/Z/ OW17/16/Z/ OW4/16/Z/ Disconnector type Dimensions [] C1 C C3 OW36/16/Z/ OW36/16/Z/390/UD OW36/16/Z/390/UG

23 Item Parameter Value 1. Rated operating voltage 3,6 [kv] 3,6 [kv] 1 [kv] 1 [kv] 4 [kv] 36 [kv] 36 [kv]. Rated continuous current 500 [] 4000 [] 500 [] 4000 [] 000 [] 500 [] 3150 [] 3. Peak current 150 [k] 150 [k] 160 [k] 160 [k] 15 [k] 15 [k] 150 [k] 4. Shortcircuit current 1 sec. 60 [k] 60 [k] 64 [k] 50 [k] 50 [k] 60 [k] 3 sec. 63 [k] 5. Test voltage (50Hz): earth and pole to pole insulation terminal to terminal insulation 10 [kv] 1 [kv] 10 [kv] 1 [kv] 8 [kv] 3 [kv] 8 [kv] 3 [kv] 50 [kv] 60 [kv] 70 [kv] 80 [kv] 70 [kv] 80 [kv] 6. Surge test voltage: earth and pole to pole insulation terminal to terminal insulation 40 [kv] 46 [kv] 40 [kv] 46 [kv] 75 [kv] 85 [kv] 75 [kv] 85 [kv] 15 [kv] 145 [kv] 170 [kv] 195 [kv] 170 [kv] 195 [kv] 7. Pole pitch: air insulation 60 [] 60 [] 300 [] 300 [] 350 [] 360 [] 50 [] 4x o X

24 X X

25 X Item Parameter Value 1. Rated operating voltage 1 [kv]. Rated continuous current 4000 [] 3. Peak current 4. Shortcircuit current, 1 sec Test voltage (50Hz): earth and pole to pole insulation terminal to terminal insulation Surge test voltage: earth and pole to pole insulation terminal to terminal insulation 190 [k] 5 [k] 76 [k] 90 [k] 8 [kv] 3 [kv] 75 [kv] 85 [kv] ~ Pole pitch air insulation 300 []

26 ~ X Y 540 Item Parameter Value 1. Rated operating voltage 660 [V]. Rated continuous current 5000 [] 3. Rated shorttime withstand current (1 sec.) 80 [k] 4. Rated peak withstand current 00 [k] Test voltage (50Hz) for insulation 3500 [V] 6. Operational category C0, DC0 7. Control switch rated voltage 50 [V] 8. Control switch rated continuous current 10 [] o18 80

27 o14 15 X D E F Item Parameter Value UW1 UW4 UDS1 UDS4 1. Rated operating voltage 1 [kv] 4 [kv] 1 [kv] 4 [kv]. Rated frequency 50 [Hz] 50 [Hz] 50 [Hz] 50 [Hz] 3. Peak withstand current 50 [k] 50 [k] 50 [k] 50 [k] 4. Rated shorttime withstand current 0 [k] 0 [k] 0 [k] 0 [k] 5. Rated shortcircuit making current 40 [k] 40 [k] Test voltage (50Hz) for earth and pole to pole insulation Surge test voltage for earth and pole to pole insulation 8 [kv] 50 [kv] 8 [kv] 50 [kv] 75 [kv] 15 [kv] 75 [kv] 15 [kv] Earthing switch type Dimensions [] C D E F UW/UDS 1 kv/ UW/UDS 1 kv/ UW 1 kv/ UW/UDS 4 kv/ UW/UDS 4 kv/ C

28 Earthing switch type Dimensions [] C D E 1 kv kv E D C 300 o14 X Value Item Parameter UWS1 UWS4 1. Rated operating voltage 1 [kv] 4 [kv]. Rated frequency 50/60 [Hz] 50/60 [Hz] 3. Peak withstand current 160/190 [k] 15 [k] 4. Rated shorttime withstand current 65/76 [k] 50 [k] 5. Test voltage (50Hz) for earth and pole to pole insulation 8/3 [kv] 50/60 [kv] 6. Surge test voltage for earth and pole to pole insulation 75/85 [kv] 15/145 [kv]

29 Item Parameter Value 1. Operating mechanism type NSW303 NSW304. pplied motor type 3. Motor rated voltage with permanent magnets 0 [VDC/C] 110 [VDC] 4 [VDC/C] series 0 [VDC/C] 4. Rated power 300 [W] 300 [W] 5. Motor rated current 6. Shaft torque: rated maximal [] / 0 [V] 4 [] / 110 [V] 19 [] / 4 [V] 150 [Nm] 300 [Nm], [] / 0 [V] 150 [Nm] 300 [Nm] 7. Switching time ca. 5s ca. 5s 8. Maximum conductor cross section 4 [ ] 4 [ ] 9. Rated mechanical strength 000 cycles 000 cycles NSW30 type without interlock 96 with interlock 306

30

31 Item Parameter Value 1. Motor rated voltage 0 [VDC/C] 110 [VDC/C]. Rated power 65 [W] 3. Motor rated current 0,5 [] / 0 [V] 1 [] / 110 [V] 4. Shaft torque max. 00 [Nm] 5. Switching time ca. 3s 6. Maximum conductor cross section 4 [ ] 7. Rated mechanical strength 000 cycles

32 W 18 3 ~65 68 W x M10 10 x M10

33

34 Item Parameter Value 1. Limiting (minimum) detection current I = 60 [μ min]. Rated detection current I = 70 [μ] 3. Substitutive impedance of a single detector phase Z = 0 [kω] 4. uxiliary contacts two pairs P 5. uxiliary contact rated load 8 [] / 30 [VC] 6. uxiliary rated voltage 8565 [VC/VDC] 7. Input power < [V] 8. Max. conductor cross section,5 [ ] WNS 48 OK L1 L L L (+) N () NC C NO NO1 C1 NC1 L3 L L1 45 Dimensions of the hole in the panel

35 Item Parameter Value 1. Rated continuous current 10 []. Insulation rated voltage I u =I th 500 [V] Rated switching currents Switching reliability at rated voltage and rated operational currents switching C electromagnets switching DC electromagnets C15 0 [V],6 [] 380 [V] 1,6 [] 500 [V] 1,6 [] DC13 4 [V] 4 [] 110 [V] 1 [] 0 [V] 0,5 [] 0. million cycles 1 million cycles to 80 [V] 1 million cycles to 10 [W] 5. Operating temperature 5<>+50 [ 0 C] 6. Connection cable crosssection: rigid stranded x 1<>1,5 [ ] x 0,75<>1,5 [ ] 7. Operating position any max NC NO NO NO NO NO NO NO NO NO NC NC NC NC NC NC NC NC

36 M1 C+1 D+1 xo Item Parameter Value 1. Insulation rated voltage 1 [kv] 4 [kv] 36 [kv]. Test voltage (50 Hz) 8 [kv] 50 [kv] 70 [kv] 3. Surge test voltage 75 [kv] 15 [kv] 170 [kv] Fuse base type Dimensions [] C D E 1 kv/ kv/ kv/ kv/ kv/

37

38

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors Technical data Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional

More information

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals NSL..S 4-pole / 8-pole Contactor Relays - Spring DC Operated Description - 1-stack contactor relays: 4-pole, - 2-stack contactor relays: 8-pole, - Mechanically linked contact elements available, - Low

More information

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

ASL09..S 3-pole Contactors - Spring Terminals

ASL09..S 3-pole Contactors - Spring Terminals 4 kw 5 hp ASL09..S 3-pole Contactors - Spring DC Operated Description - 3-pole contactors with spring terminals, - N.C. or N.O. built-in auxiliary contact, - Low coil consumption, - Polarity on the coil

More information

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC SIRCO PV IEC 609473 The solution for Load break switches > Combiner box > Recombiner box > Inverter sircopv_058_a_1_cat sircopv_059_a_1_cat Strong points Function SIRCO PV are manually operated multipolar

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101419D0201 06/04/11-40-00-.. / Z-40-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440

More information

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101412D0201 25/03/11-30-00-.. / Z-30-00-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet SBC042D020 06/04/ -22-00-.. / Z-22-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440 V DC.

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

CATALOGUE. ON Medium Voltage Outdoor Disconnectors

CATALOGUE. ON Medium Voltage Outdoor Disconnectors CATALOGUE ON Medium Voltage Outdoor Disconnectors 2 O N M E D I U M V O LTA G E O U T D O O R D I S C O N N E C TO R S ON MEDIUM VOLTAGE OUTDOOR DISCONNECTORS 3 Table of conteants 004 1. Introduction 004

More information

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101408D0201 25/03/11-30-01-.. / Z-30-01-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD. DATASHEET - DILMC9-10(24VDC) Technical data General Contactor, 3p+1N/O, 4kW/400V/AC3 Part no. DILMC9-10(24VDC) Catalog No. 277468 Eaton Catalog No. XTCEC009B10TD EL-Nummer 4110305 (Norway) Standards IEC/EN

More information

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors 90 Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 5424 Product certifications LCp

More information

Description. Positive safety relays

Description. Positive safety relays Type N & KC Positive safety Description A.C. or D.C. operated DIN rail or panel mounting 600 volt heavy duty design, A600-10 amp, Q300-5 amp Snap-on accessories available: 1 & 4 pole adder deck Pneumatic

More information

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101415D0201 25/03/11 AF30-30-11-.. / AF30Z-30-11-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF30(Z) contactors are used for controlling power circuits

More information

Short form catalogue. Motor protection & control

Short form catalogue. Motor protection & control Short form catalogue Star Series Motor protection & control Motor Protection and Control up to 25 HP / 600 VAC Overview...2 Contactors and Overload Relays...11 4-pole Contactors...41 Control Relays...59

More information

Technical Information

Technical Information C5 C5- C5- C5- C5- C5-550 ➊ 700 860 1000 1200 Rated Insulation Voltage U i to IEC 947-1 [V] 1000V 1000V 1000V 690V 690V UL/CS [V] 600V Rated Impulse Voltage U imp C5-550 / 700 / 860 [kv] 3.5 C5-1000 /

More information

Miniature Circuit Breaker

Miniature Circuit Breaker Introduction - Miniature Circuit Breaker (MCB) SALIENT FEATURES SALIENT FEATURES Standards MCBs conform to the latest standard IS 8828: 1996/IEC: 898 1995 Mid-Trip Position The Mid trip position of the

More information

TAE pole Contactors

TAE pole Contactors TAE9...26 3-pole Contactors d.c. operated with double-winding coil SB8033C3 Utilisation TAE9 to TAE26 contactors are a compliment to the DC control contactor range. The coils have large voltage ranges

More information

Fuse switch disconnectors

Fuse switch disconnectors SWITCHGEAR RBK Fuse switch disconnectors intended for distribution of electricity and protection of electrical equipment against short-circuits and overloads, with industrial fuse links ENERGY SAFELY SWITCHED

More information

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS A. 11 KV SWITCHGEAR 1.0 SWITCHGEAR ASSEMBLY 1.1 Make : 1.2 Type : 1.3 Reference Standard : 1.4 Voltage (Nom./Max.) KV : 1.5 Phase, Frequency No,Hz.

More information

Indoor switches for railway lines. single-pole design rated voltage up to 27,5 kv rated current up to 4000 A

Indoor switches for railway lines. single-pole design rated voltage up to 27,5 kv rated current up to 4000 A Indoor switches for railway lines single-pole design rated voltage up to 27,5 kv rated current up to 4000 A General These Driescher indoor switching devices are specifically designed for railway applications.

More information

AE 9... AE 40 Contactors NE... Contactor Relays

AE 9... AE 40 Contactors NE... Contactor Relays Technical data AE 9... AE 0 Contactors NE... Contactor Relays AE 9... AE 0 Contactors NE.. Contactor Relays Contents AE 9... AE 0 Contactors Description... 2 Ordering Details... 3 Technical Data... Terminal

More information

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB6, VB7 -pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated VB7-0-10 2CDC211006F0011 Description VB6, VB7 -pole compact design reversing contactors are space optimized control

More information

vertical fuse switch disconnectors

vertical fuse switch disconnectors SWITCHGEAR ARS vertical fuse switch disconnectors - touch protection IP 30 from the front - fibre glass extra strenghtened, self extinguishing thermoplastics - double clearance between open contacts -

More information

Modular contactor for installation into distribution boards

Modular contactor for installation into distribution boards Modular contactor for installation into distribution boards Description Modular contactors are used for installation in consumer units in dwellings, business premises, hotels, hospitals, shopping centres,

More information

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated 11Across the line UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated contactor frame size A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AL A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF A/AE/AF

More information

xxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads

xxx.1xx xxx.4xx0. AgNi contacts, specifically intended for resistive and slightly inductive loads as well as for motor loads 22 Series - Modular contactors 25-40 - 63 22 SERIES Features 22.32.0.xxx.1xx0 22.32.0.xxx.4xx0 25 modular contactor - 2 pole 17.5 mm wide NO contact gap 3 mm, double break Continuous duty for the coil

More information

Star Series Motor protection & control

Star Series Motor protection & control Contact us ABB Inc. Low Voltage Control Products 16250 W. Glendale Drive New Berlin, WI 53151 Phone: 888-385-1221 Fax: 800-726-41 USA Technical support & Customer Service: 888-385-1221, Option 4 7:30AM

More information

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC Load break switches SIRCO PV IEC 609473 new The solution for > Combiner box > Recombiner box > Inverter sircopv_058_a_1_cat sircopv_059_a_1_cat Strong points Function SIRCO PV are manually operated multipolar

More information

Application Mini Contactors for Motors and Resistive Loads

Application Mini Contactors for Motors and Resistive Loads Delivery program Contactor, 4p, 4kW/400V/AC3 Part no. DILEM4-G(24VDC) Catalog No. 012701 Eaton Catalog No. XTMF9A00TD Product range Contactors Application Mini Contactors for Motors and Resistive Loads

More information

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy otor Controllers AC Semiconductor otor Controller Type RSHP Flexy Soft starting and stopping of 3-phase squirrel cage motors Low surge and vibration-free starting User-selected ramping profiles Integral

More information

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, 4 Electrics for Rolling Stock Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, Change-Over-Switches 600 V to 3 kv Catalogue F84.en

More information

15 16 MCCBs for Power Distribution Technical Specification Frame 100A 250A 250A 400A 400A 630A 800 / 1000 / 1250 Type C DN0-100 D DN1-250 N DN2-250 D N S H DN3B-400 DN3-400 D N D N S V DN3-630 DN4-1250

More information

S&S POWER SWITCHGEAR EQUIPMENT LTD.,

S&S POWER SWITCHGEAR EQUIPMENT LTD., S&S POWER SWITCHGEAR EQUIPMENT LTD., Works: No.4, EVR Street, Sederapet, Puducherry 605 111, India. Corporate Office: Plot No:14, CMDA Industrial Area-II, Chithamanur Village, Maraimalai Nagar-603209,

More information

Auxiliary contact blocks - with spring terminals Accessories

Auxiliary contact blocks - with spring terminals Accessories Auxiliary contact blocks - with spring terminals Accessories CA3-10S 1SBC101037F0014 Description The auxiliary contact blocks are used for the operation of auxiliary circuits and control circuits. CA3

More information

K50H004UP cam changeover switch - 4-pole A - screw mounting

K50H004UP cam changeover switch - 4-pole A - screw mounting Characteristics cam changeover switch - 4-pole - 60-50 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

Solid State Relays, 3-phase

Solid State Relays, 3-phase PMA Prozeß- und Maschinen-Automation GmbH Solid State Relays, 3-phase Zero-Point switching, heatsink integrated Main Characteristics: Three-phase controlled Zero switching LED display Various connection

More information

3TM Vacuum Contactors

3TM Vacuum Contactors Catalog Extract HG 11.23 Edition 2016 Catalog Extract Medium-Voltage Equipment siemens.com/3tm R-HG11-343.psd 2 Siemens HG 11.23 2016 Contents Medium-Voltage Equipment Catalog Extract HG 11.23 2016 Contents

More information

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France Contact us ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F-69687 Chassieu cedex / France You can find the address of your local sales organisation on

More information

FL series position switches

FL series position switches FL series position switches Selection diagram 0 08 0 9 0 0 0 Ball Ø. External rubber Ball Ø 8 mm, mm, stainless Glass fibre rod gasket stainless steel steel Adjustable lever Adjustable safety lever Bistable

More information

K30H001YP cam star-delta switch - 3-pole A - screw mounting

K30H001YP cam star-delta switch - 3-pole A - screw mounting Characteristics cam star-delta switch - 3-pole - 60-32 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX IEC-Contactor RSC 1 Features Rated operational current 9 63 (C-3) Coil voltages C 24, 230V 3 main contacts and auxiliary contact Extendable with auxiliary contact block Mounting position any 2 Description

More information

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG Medium-Voltage Equipment Selection and Ordering Data Catalog HG 11.02 2011 Answers for energy. R-HG11-172.tif 2 Siemens HG 11.02 2011 Contents SION Vacuum Circuit-Breakers Medium-Voltage Equipment Catalog

More information

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions to 00 A Accessories Enclosed Characteristics M e atysm_007_a cat M s atysm_0_a cat products are and 4pole switches remotely controlled by volt free contacts ( ) or automatic transfer switches ( ). They

More information

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors MOTOR STARTERS SM Basic function Switching and protection of motors up to A Protection against short-circuit and protection against overload The device responds to phase failure The device is provided

More information

CI-TI Contactors and motor starters Types CI 61 - CI 98

CI-TI Contactors and motor starters Types CI 61 - CI 98 Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

IP41. Enclosed Switchgear. Hinged Lid IP41 Enclosures. for technical support call: +44(0) General Description.

IP41. Enclosed Switchgear. Hinged Lid IP41 Enclosures. for technical support call: +44(0) General Description. General Description Supplied in hinged lid grey powder coated sheet steel enclosures, these IP41 sealed assemblies are eminently suitable for most indoor industrial applications. Supplied as Switch-Disconnectors

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

NXPLUS C Single busbar. Maintenance-free for lifetime

NXPLUS C Single busbar. Maintenance-free for lifetime NXPLUS C Single busbar Maintenance-free for lifetime Energy Distribution Welcome! Page 2 Content Overview Technical data Typicals Panel design Circuit-Breaker panel Busbar Operation Metering Low-voltage

More information

Solid State Relays contactor with Integrated Fuse Type RGC1F

Solid State Relays contactor with Integrated Fuse Type RGC1F Solid State Relays contactor with Integrated Fuse Type RGC1F Solid State Contactor with integrated fuse Zero Cross Switching Operational voltage: 230 VAC and 600 VAC 35mm width Control voltage: 4-32 VDC

More information

Industrial Contactors CTX 3 3P 185A - 800A

Industrial Contactors CTX 3 3P 185A - 800A 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Industrial Contactors CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Installation - Connection...

More information

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A Fuse protection The solution for > Motor load break > Protection of industrial cabinet > Electrical distribution fusom_063_b_1_cat Strong points > Tripping upon overload > High breaking capacity > Improved

More information

DIN EN UL 508 / CSA 3RF A A 0 2

DIN EN UL 508 / CSA 3RF A A 0 2 PMA Prozeß- und Maschinen-Automation GmbH Solid State Relays Zero-Point Switching, heatsink integrated Main Characteristics: Zero switching LED display Various connection technologies Plug-in control terminal

More information

Technical specifications

Technical specifications Technical specifications Type 3RW30 03 3RW3-1B0 3RW3-1B1 Control electronics Rated control supply voltage V 24 230 CDC 24 CDC (+10 %-15 %) 110 230 CDC (+10 %-15 %) Rated control supply Without fanwith

More information

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A)

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A) Controls THERMAL OVERLOAD RELAYS RW..D (up to 0A) 0800 7 9 Thermal Overload Relays RW..D (up to 0A) THERMAL OVERLOAD RELAYS RW..D (up to 0A) Summary Introduction RW7-D Thermal Overload Relay from 0.8 up

More information

TECHNICAL DESCRIPTION

TECHNICAL DESCRIPTION DC Circuit Breaker TECHNICAL DESCRIPTION TRK5650523200 Ed.1 of 23/07/13 CONTENTS 1. INTRODUCTION... 2 2. DESCRIPTION... 2 2.1 Description of circuit breaker... 2 2.2 Operating mode... 2 2.3 Variants and

More information

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable www.siemens.com/medium-voltage-switchgear Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable Medium-Voltage Switchgear Catalog HA 41.43 2012 Answers for infrastructure and cities. Neue Bilder

More information

For Info: Phone: Fax:

For Info:   Phone: Fax: Page -2 TWO POLES IEC rated current Ith: 20A (AC1) IEC operational power: 1.3kW (AC3 230V) Ideal for domestic applications. Page -2 THREE AND FOUR POLES IEC rated current Ith: 25A, 40A and 63A (AC1) IEC

More information

Low Surge Special WCAg contact limits the chopping current up to 1A to protect the load from high surge.

Low Surge Special WCAg contact limits the chopping current up to 1A to protect the load from high surge. Vacuum Contactor HYUNDAI Vacuum Contactors are designed and manufactured for frequent switchings, especially taking into account safety and quality assurance. They are suitable for switching and controlling

More information

Section 2 - Substation Switchgear

Section 2 - Substation Switchgear Switchgear & Protection : Section 2 Section 2 - Table of Contents Section/Page Introduction to DB36 - D362 Disconnectors (36kV - 362kV)... 2-2 Popular Options For DB36, DB72 & DB145... 2-3... 2-3 Popular

More information

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11 2.4 AZM 170 range Features Thermoplastic enclosure Compact design Manual release Long life Double insulated X High holding force 1,000 N N latching force Cut clamp termination Actuation on de-energisation

More information

Contactor Types CI 61-98

Contactor Types CI 61-98 MKING MODERN LIVING POSSIBLE Data sheet Contactor s CI 6-98 Contactors CI 6, CI 73, CI 86 and CI 98 switch powers of up to 30 kw, 37 kw, 45 kw and 55 kw respectively under 3 380 V C-3 loads. ccessories

More information

7.0 Technical Guarantee Specification of 60MVA, 132/33kV Mobile Substation. TECHNICAL DATA SCHEDULE 60MVA, 132/33 kv MOBILE SUBSTATION

7.0 Technical Guarantee Specification of 60MVA, 132/33kV Mobile Substation. TECHNICAL DATA SCHEDULE 60MVA, 132/33 kv MOBILE SUBSTATION 92 Section VI. Schedule of Requirements 7.0 Technical Guarantee Specification of 60MV, 132/33 Mobile Substation TECHNICL DT SCHEDULE 60MV, 132/33 MOBILE SUBSTTION ITEM DESCRIPTION UNITS REQUIRED GURNTEED

More information

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660 Characteristics Environment Rated insulation voltage (Ui) Conforming to IEC/EN 60947-1, V 690 IEC/EN 60947-4-1, VDE 0110 gr C, CSA - n 14, UL 508.1 Conforming to standards IEC/EN 60947-1, IEC/EN 60947-4-1,

More information

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN Motor Contactor Main contactor AC & DC operated Integrated auxiliary contacts Screw fixing and snap fitting (35 mm DIN rail) up to 45 kw Range from 4 to 110 kw (AC 3, 380/415V) Finger proof ( VBG 4) Accessoires

More information

Modular Contactors and Switches D681E121

Modular Contactors and Switches D681E121 Modular Contactors and Switches D681E121 Modular Contactors and Switches Modular Contactors 2, 3 Aux. contact block 3 Accessories 3 Day Night Reloading Contactors 4 Safety Switches 5 Main Switches Emergency

More information

Power IT Pole Mounted Switch Disconnector, NPS. 630 A, up to 36 kv

Power IT Pole Mounted Switch Disconnector, NPS. 630 A, up to 36 kv Power IT Pole Mounted Switch Disconnector, NPS 60 A, up to 6 kv NPS Pole Mounted Switch Disconnectors 60 A up to 6 kv Index Description... Selection table... 5 Technical data and ordering information Rocking

More information

Meta Solution. Contactors and Overload relays

Meta Solution. Contactors and Overload relays Meta Solution Contactors and Overload relays Meta Solution New generation of Contactors from LSIS Contactors and Overload Relays Metasol Contactors Designed to show superior technology: The Metasol series

More information

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101428D0201 28/03/11 -.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits. NF(Z)

More information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases Index Page Circuit-Breakers M4 166 for motor protection Auxiliary contacts 167 Signalling switch Auxiliary releases Insulated 3-pole busbar system 168 Terminal block DIN-rail adapters 169 Busbar adapters

More information

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable Medium-Voltage Switchgear Totally Integrated Power SIMOSEC Catalog HA 41.43 Edition Sept. 2014 Answers for infrastructure and cities. Neue

More information

Series CA5 Contactors

Series CA5 Contactors Series C5 Contactors The contactor for heavy industrial applications from 500HP to 900HP DISCONTINUED This series is being replaced by the C9 Series of contactors C5 Series contactors provide large horsepower

More information

A Contactors. Technical Information. CA4 Miniature Contactors. Technical Information A94 CA4. Switching Motor Loads.

A Contactors. Technical Information. CA4 Miniature Contactors. Technical Information A94 CA4. Switching Motor Loads. C4 Miniature Contactors Contactors C4 Rated Insulation Voltage U i to IEC 947-1 [V] 500V UL/CS [V] 600V Rated Impulse Voltage U imp [kv] 8 Rated Voltage U e Main Contacts C 50/60Hz [V] 230, 240, 400, 415,

More information

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus DISTRIBUTION SOLUTIONS GSec Gas-insulated switching and isolating apparatus GSec is a three-position SF6 gas-insulated switchdisconnector designed for use in medium voltage switchgear for secondary distribution

More information

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards Medium Voltage Switchgear Primary Distribution CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka General description Presentation Ormazabal s CPG System includes the CPG.1

More information

LK Position Switches TECHNICAL DATASHEET.

LK Position Switches TECHNICAL DATASHEET. LK Position Switches Technopolymer housing, one conduit entry Protection degree IP6 according to EN 60529 contact blocks available 46 actuators available Versions with stainless steel external parts Versions

More information

CI-TI Contactors and Motor Starters Type CI 6-50

CI-TI Contactors and Motor Starters Type CI 6-50 Data sheet CI-TI Contactors and Motor Starters CI 6-50 CI-TI contactors and motor starters provide trouble-free switching and maximum protection for costly motors and other electrical equipment. The components

More information

Unified requirements for systems with voltages above 1 kv up to 15 kv

Unified requirements for systems with voltages above 1 kv up to 15 kv (1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) (Corr.1 June 2018) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements

More information

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A Load break switches SIRCO MV PV sircm-pv_010_a_1_cat The solution for > Residential buildings > Buildings > Solar parks Strong points SIRCO MV PV 1000 V - 80 A direct operation > Modular device > Patented

More information

Power distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly

Power distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly NH fuse-switch disconnectors, size 000 Version -pole, cable outlet at the top/bottom For the use of fuse inserts to EN 60 - Technical specifications to IEC/EN 60 947-, see chapter -5, page 6 see chapter

More information

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data B6, B7, BC6, BC7, TBC7 - and 4-pole mini contactors VB6, VB7, VBC6, VBC7 - and 4-pole mini reversing contactors Main pole Utilization characteristics according to IEC Standards IEC/EN 60947-1, IEC/EN 60947-4-1

More information

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A Fuse protection fuser_548_a_1_cat The solution for > Motor load break > Protection of industrial processes FUSERBLOC 63 to 125 A Strong points fuser_532_a_1_cat Function FUSERBLOC 32 to 4 A FUSERBLOC are

More information

SF6 LOAD BREAK SWITCH. Remote Controlled OCR TELE_1_2013.EN

SF6 LOAD BREAK SWITCH. Remote Controlled OCR TELE_1_2013.EN SF6 LOAD BREAK SWITCH Remote Controlled OCR TELE_1_2013.EN INDEX Overview IA780 MOTOR OPERATED Presentation Standards Structural Characteristics 3 3 3 Construction characteristics Components Breaking technology

More information

CONTACTOR, AC-3 15 KW/400 V, AC 110V 50HZ/120V 60HZ 3-POLE, SIZE S2, SCREW CONNECTION. General technical data: Main circuit: product brand name

CONTACTOR, AC-3 15 KW/400 V, AC 110V 50HZ/120V 60HZ 3-POLE, SIZE S2, SCREW CONNECTION. General technical data: Main circuit: product brand name Product data sheet CONTACTOR, AC-3 15 KW/400 V, AC 110V 50HZ/120V 60HZ 3-POLE, SIZE S2, SCREW CONNECTION General technical data: product brand name Size of contactor Protection class IP / on the front

More information

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30 Characteristics TeSys contactors Mini-contactors TeSys LC SK and LP SK Environment Rated insulation voltage (Ui) Conforming to 0, VDE 00 gr C,BS, CSA - n, UL 0 V 0 Conforming to standards IEC 0, NF C -0,

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Safety Interlock Switches D4JL D4JL For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. uard Lock Safety-Door Switch Holding

More information

Softstarter Intelligent Controllers

Softstarter Intelligent Controllers Softstarter Intelligent Controllers Series Modes of Operation (Standard) Soft Start 100% Percent Voltage Initial Torque Start Run This method has the most general application. The motor is raised from

More information

4.7. Definite Purpose Contactors and Starters. Contents. Reversing/Assignment Contactor. Direct Current Contactors

4.7. Definite Purpose Contactors and Starters. Contents. Reversing/Assignment Contactor. Direct Current Contactors Direct Current Contactors.7 Contents Description Mill Type Contactors....................... 600V Contactors.......................... DPM 750V Contactor...................... AVD Contactor...........................

More information

Contactors. CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en. Connect - Contact - Control

Contactors. CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en. Connect - Contact - Control Connect - Contact - Control 3 Contactors CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en More information at: schaltbau-gmbh.com 42 CH1130/02 Single pole high-voltage contactor

More information

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG Medium-Voltage Equipment Selection and Ordering Data Catalog HG 11.0 008 Answers for energy. R-HG11-17.tif Siemens HG 11.0 008 Contents Contents Page SION Vacuum Circuit-Breakers Description General Construction

More information

BETA Switching Switches and Light Indicators

BETA Switching Switches and Light Indicators Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET

More information

IEC Low Voltage General Purpose Protection

IEC Low Voltage General Purpose Protection , 6A, 0/400VAC (/440VAC) Complying with DIN VDE 0660 Part 07 EN / IEC 60947- DIN VDE 066 Part IEC 6069- DIN VDE 068 DIN VDE 4880 The D0-LINOCUR is a combination of switch-disconnector-fuse and NEOZED 6

More information

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30 Contactors KNL KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30 Adaptable to various control requirements with ability of mounting from one to four additional auxiliary contacts. Versatile product capable

More information

Application Mini Contactors for Motors and Resistive Loads

Application Mini Contactors for Motors and Resistive Loads Deliveryprogramme Contactor,3p+1N/O,4kW/400V/AC3 Partno. DILEM-10-G(24VDC) Articleno. 010213 CatalogNo. XTMC9A10TD Product range Contactors Application Mini Contactors for Motors and Resistive Loads Subrange

More information