1492 ACABLE 050 A. A-Cable Type TA, TB, TC, TD, UA, UB, UC, UD, VA, VB, WA, WB, X, Y, Z, ZA, ZB, ZC 1492 ACAB 005 A46. Cable Type

Size: px
Start display at page:

Download "1492 ACABLE 050 A. A-Cable Type TA, TB, TC, TD, UA, UB, UC, UD, VA, VB, WA, WB, X, Y, Z, ZA, ZB, ZC 1492 ACAB 005 A46. Cable Type"

Transcription

1 Digital/Analog Programmable Controller and PowerFlex Drive Wiring Systems Pre-Wired Cable Catalog Number Explanation for Bulletins,, and Analog I/O Modules Important: The following analog cable catalog number breakdown is for explanation purposes only. It is not a product configurator. All combinations of fields are not valid product catalog numbers. First, select the desired AIFM using the steps in Ordering Digital and Analog Wiring Systems on page. Then, use this breakdown for verification and explanation only. ACABLE A Bulletin No. Analog Interface Cables Standard or Build-to-Order Cable. m (. ft) Standard. m (. ft). m (. ft). m (. ft) -.. m (.. ft). m (. ft increments) Build-to-Order -.. m (.. ft). m (. ft) increments -.. m (.. ft). m (. ft) increments A-Cable Type A, B, C, D, Pre-wired cables for Bulletin analog I/O and K, L, P, Q, R RTD input modules. E, F, G, H, J Pre-wired cables for Bulletin analog I/O and RTD input modules. TA, TB, TC, TD, UA, UB, UC, UD, VA, VB, WA, WB, X, Y, Z, ZA, ZB, ZC YT M Pre-wired cables for Bulletin analog I/O, RTD, and -ITI thermocouple input modules. Pre-wired cable for bulletin -ITI thermocouple input Module. Pre-wired cables for Bulletin pulse input module. Pre-Wired Cable Catalog Number Explanation for Bulletin,,, and PowerFlex Analog I/O Modules Important: The following analog cable catalog number breakdown is for explanation purposes only. It is not a product configurator. All combinations of fields are not valid product catalog numbers. First, select the desired AIFM using the steps in Ordering Digital and Analog Wiring Systems on page. Then, use this breakdown for verification and explanation only. ACAB A Bulletin No. Analog Interface Cables Standard or Build-to-Order Cable. m (. ft) Standard. m (. ft). m (. ft). m (. ft) -.. m (.. ft). m (. ft increments) Build-to-Order -.. m (.. ft). m (. ft) increments -.. m (.. ft). m (. ft) increments Cable Type A AA, AB, BA, BB, BC, BD, CA, CB, CC, EA, EB, EC, ED, C, D, HA ZH XS, ZS Z Pre-wired cables for Bulletin -NII and -NIV analog modules. Pre-wired cables for Bulletin analog I/O modules and RTD input module. Pre-wired cable for PowerFlex H Pre-wired cables for PowerFlex S Pre-wired cables for Bulletin analog I/O modules Publication -TDD-EN-P - January

2 Digital/Analog Programmable Controller and PowerFlex Drive Wiring Systems IFMs for Bulletin Analog I/O Modules (Continued) Description of AIFM -channel Input with V DC blown fuse indicators, terminals/channel -channel Input with V DC blown fuse indicators, terminals/channel -input /-output channel with fuses and V blown fuse indicators for Wiring System Module with Fixed Terminal Block for Wiring System Module with Removable Terminal Block Socket Assembly (order plugs separately I/O Module - IFE (Differential) -AIFM-F- F F -AIFM-F- F F -AIFMQS IFE (Single-Ended) IFF (Differential) IFF (Single-Ended) IL IR OFE OFE OFE ➊ ➋ ➌ ➍ ➎ Cables are available in standard lengths of. m,. m,. m, and. m. To order, insert the code for the desired cable length into the catalog number =. m ( =. m, =. m, and =. m), and insert the letter in the box. Example: -ACABLEH is for a. m cable, and the letter H. Cannot be used with I/O. Compatible Removable Terminal Block (RTB) plug; -RTBN (screw style terminals) or -RTBP. ORDER PLUGS SEPARATELY. Compatible Removable Terminal Block (RTB) plug; -RTBN (screw style terminals) or -RTBP. ORDER PLUGS SEPARATELY. Compatible Removable Terminal Block (RTB) plug; -RTBN (screw style terminals) or -RTBP. ORDER PLUGS SEPARATELY. Pre-Wired Cables for Bulletin Analog I/O Modules These pre-wired cables have a wiring arm on one end to connect to the front of a Bulletin analog I/O module and a connector on the other end to plug into a - or -pin D-shell terminal AIFM. You must first select the AIFM from the preceding selection table. Cable Catalog Standard Cable s Build-to-Order Available AIFM Connector Mating I/O Modules Number -ACABLE➊E.,.,.,. m Yes -pin D-shell -IFE, -IFF Differential -ACABLE➊F.,.,.,. m Yes -pin D-shell -IFE, -IFF Single-Ended -ACABLE➊G.,.,.,. m Yes -pin D-shell -OFE, -OFE, -OFE -ACABLE➊H.,.,.,. m Yes -pin D-shell -IL -ACABLE➊J.,.,.,. m Yes -pin D-shell -IR ➊ Cables are available in standard lengths of. m,. m,. m, and. m. To order, insert the code for the desired cable length into the catalog number ( =. m, =. m, =. m, and =. m). Example: -ACABLEE is for a. m cable that could be used to connect a Catalog Number -AIFM- IFM to a -IFE I/O module. Build-to-order lengths are also available. Publication -TDD-EN-P - January

3 Digital/Analog Programmable Controller Wiring Systems Specifications Digital/Analog Programmable Controller Wiring Systems Bulletin pre-wired cables are designed to minimize control wiring in a panel. Analog pre-wired cables, when used with an AIFM, replace the pointto-point wiring between Allen-Bradley programmable controller I/O modules and individual terminal blocks. The analog ready-to-wire cables provide one end of the cable pre-terminated for an AIFM (AIFM-ready cable). Pre-Wired Cables Specifications The pre-wired cables have a Bulletin Removable Terminal Block, Bulletin Removable Terminal Block, Bulletin Removable Terminal Block, Bulletin Wiring Arm, or Bul. (Flex) -pin D-Shell (mates with Cat. No. -TBDS) on one end and a D-shell on the other to connect to the AIFM. All analog cables have an overall shield and most have # AWG twisted pairs for additional noise immunity. In addition, most analog cables have prepared ring lugs on the drain wire for convenient grounding of the cable shield to the programmable controller chassis. The broad offering of analog pre-wired cables supports over different Bulletin,,,, S, H, and analog, RTD, and thermocouple ( only) I/O modules. Publication -TDD-EN-P -January

4 Digital/Analog Programmable Controller Wiring Systems Specifications, Continued Pre-Wired Cables, Continued Analog Pre-Wired Cable Specifications and ➊ Standard Cable s I/O Module Connector AIFM Connector No. of Conductors ➋➌ Insulation Rating Conductor Size Nominal Outer Diameter -ACABLE➊A.,.,.,. m -RT -Position Removable Terminal Block -pin D-shell Twisted Pairs V C AWG. mm (.") -ACABLE➊B.,.,.,. m -RT -Position and -RT -Position Removable Terminal Block -pin D-shell Twisted Pairs V C AWG. mm (.") -ACABLE➊C.,.,.,. m -RTG Green Removable Terminal Block -pin D-shell Twisted Pairs V C AWG. mm (.") -ACABLE➊D.,.,.,. m -RTG Green Removable Terminal Block -pin D-shell Conductors V C AWG. mm (.") -ACABLE➊E.,.,.,. m -WG ( terminal) -pin D-shell Twisted Pairs V C AWG. mm (.") -ACABLE➊F.,.,.,. m -WG ( terminal) Wiring Arm -pin D-shell Conductors V C AWG. mm (.") -ACABLE➊G.,.,.,. m -WC ( terminal) Wiring Arm -pin D-shell Twisted Pairs V C AWG. mm (.") -ACABLE➊H.,.,.,. m -WF ( terminal) Wiring Arm -pin D-shell Twisted Pairs V C AWG. mm (.") -ACABLE➊J.,.,.,. m -WF ( terminal) Wiring Arm -pin D-shell Conductors V C AWG. mm (.") -ACABLE➊K.,.,.,. m -RTG Green Removable Terminal Block -pin D-shell Twisted Pairs V C AWG. mm (.") -ACABLE➊L.,.,.,. m -RT -Position Removable Terminal Block -pin D-shell Twisted Pairs V C AWG. mm (.") -ACABLE➊M.,.,.,. m -TBCH -Position Removable Terminal Block -pin D-shell Twisted Pairs V C AWG. mm (.") -ACABLE➊P.,.,.,. m -RTG Green Removable Terminal Block -pin D-shell Twisted Pairs V C AWG. mm (.") -ACABLE➊Q.,.,.,. m -QS ( terminal D-shell) -pin D-shell Twisted Pairs V C AWG. mm (.") -ACABLE➊R.,.,.,. m -RTG Green Removable Terminal Block -pin D-shell Conductors V C AWG. mm (.") -ACABLE➊X.,.,.,. m -TBNH -Position Removable Terminal Block -pin D-shell Twisted Pairs V C AWG. mm (.") -ACABLE➊Y.,.,.,. m -TBNH -Position Removable Terminal Block -pin D-shell Twisted Pairs V C AWG. mm (.") -ACABLE➊YT.,.,.,. m -TBNH -Position Removable Terminal Block -pin D-shell Twisted Pairs V C AWG. mm (.") -ACABLE➊Z.,.,.,. m -TBNH -Position Removable Terminal Block -pin D-shell Conductors V C AWG. mm (.") -ACABLE➊A.,.,.,. m -RTG Green Removable Terminal Block -pin D-shell Conductors V C AWG. mm (.") -ACABLE➊TA.,.,.,. m -TBCH -Position Removable Terminal Block -pin D-shell Conductors V C AWG. mm (.") -ACABLE➊TB.,.,.,. m -TBCH -Position Removable Terminal Block -pin D-shell Conductors V C AWG. mm (.") -ACABLE➊TC.,.,.,. m -TBCH -Position Removable Terminal Block -pin D-shell Twisted Pairs V C AWG. mm (.") -ACABLE➊TD.,.,.,. m -TBCH -Position Removable Terminal Block -pin D-shell Twisted Pairs V C AWG. mm (.") -ACABLE➊UA.,.,.,. m -TBCH -Position Removable Terminal Block -pin D-shell Conductors V C AWG. mm (.") -ACABLE➊UB.,.,.,. m -TBCH -Position Removable Terminal Block -pin D-shell Conductors V C AWG. mm (.") -ACABLE➊UC.,.,.,. m -TBCH -Position Removable Terminal Block -pin D-shell Twisted Pairs V C AWG. mm (.") -ACABLE➊UD.,.,.,. m -TBCH -Position Removable Terminal Block -pin D-shell Twisted Pairs V C AWG. mm (.") -ACABLE➊VA.,.,.,. m -TBNH -Position Removable Terminal Block -pin D-shell Conductors V C AWG. mm (.") -ACABLE➊VB.,.,.,. m -TBNH -Position Removable Terminal Block -pin D-shell Conductors V C AWG. mm (.") -ACABLE➊WA.,.,.,. m -TBNH -Position Removable Terminal Block -pin D-shell Twisted Pairs V C AWG. mm (.") -ACABLE➊WB.,.,.,. m -TBNH -Position Removable Terminal Block -pin D-shell Twisted Pairs V C AWG. mm (.") -ACABLE➊XA.,.,.,. m -TBCH -Position Removable Terminal Block -pin D-shell Twisted Pairs V C AWG. mm (.") -ACABLE➊XB.,.,.,. m -TBCH -Position Removable Terminal Block -pin D-shell Twisted Pairs V C AWG. mm (.") -ACABLE➊ZA.,.,.,. m -TBCH -Position Removable Terminal Block -pin D-shell Conductors V C AWG. mm (.") -ACABLE➊ZB.,.,.,. m -TBCH -Position Removable Terminal Block -pin D-shell Conductors V C AWG. mm (.") -ACABLE➊ZC.,.,.,. m -TBCH -Position Removable Terminal Block -pin D-shell Conductors V C AWG. mm (.") -ACAB➊AA.,.,.,. m -RTBN -Position Removable Terminal Block -pin D-shell Twisted Pairs V C AWG. mm (.") -ACAB➊AB.,.,.,. m -RTBN -Position Removable Terminal Block -pin D-shell Twisted Pairs V C AWG. mm (.") -ACAB➊BA.,.,.,. m -RTBN -Position Removable Terminal Block -pin D-shell Twisted Pairs V C AWG. mm (.") -ACAB➊BB.,.,.,. m -RTBN -Position Removable Terminal Block -pin D-shell Twisted Pairs V C AWG. mm (.") -ACAB➊BC.,.,.,. m -RTBN -Position Removable Terminal Block -pin D-shell Twisted Pairs V C AWG. mm (.") -ACAB➊BD.,.,.,. m -RTBN -Position Removable Terminal Block -pin D-shell Twisted Pairs V C AWG. mm (.") -ACAB➊C.,.,.,. m -RTBN -Position Removable Terminal Block -pin D-shell Conductors V C AWG. mm (.") -ACAB➊CA.,.,.,. m -RTBN -Position Removable Terminal Block -pin D-shell Conductors V C AWG. mm (.") -ACAB➊CB.,.,.,. m -RTBN -Position Removable Terminal Block -pin D-shell Conductors V C AWG. mm (.") -ACAB➊CC.,.,.,. m -RTBN -Position Removable Terminal Block -pin D-shell Conductors V C AWG. mm (.") -ACAB➊D.,.,.,. m -RTBN -Position Removable Terminal Block -pin D-shell Conductors V C AWG. mm (.") -ACAB➊EA.,.,.,. m -RTBN -Position Removable Terminal Block -pin D-shell Conductors V C AWG. mm (.") -ACAB➊EB.,.,.,. m -RTBN -Position Removable Terminal Block -pin D-shell Conductors V C AWG. mm (.") -ACAB➊ED.,.,.,. m -RTBN -Position Removable Terminal Block -pin D-shell Conductors V C AWG. mm (.") -ACAB➊HA.,.,.,. m -RTBN -Position Removable Terminal Block -pin D-shell Twisted Pairs V C AWG. mm (.") Publication -TDD-EN-P -January

5 Digital/Analog Programmable Controller Wiring Systems Specifications, Continued Pinouts, Continued Red () Black () White () Black () Red () Black () Yellow () Black () Green () Black () Blue () Black () Yellow () Black () White () Black () Green () Black () Blue () Black () Red () Black () White () Black () Green () Black () Blue () Black () Drain Yellow () Black () Brown () Black () Orange () Black () Red () White () -ACABLE A -ACABLE B -ACABLE C Blue () White/Violet () Green () White/Yellow () White/Orange () Orange () White/Blue () White/Green () Yellow () White/Red () White/Brown () Red () Red () Black () White () Black () Green () Black () Blue () Black () Yellow () Black () Brown () Black () Orange () Black () Red () White () Red () Green () Red () Brown () Black () White () Orange () White/Black () White/Brown () White/Red () White/Orange () Blue () Violet () Gray () White/Black/Brown () White/Gray () Green () White/Violet () White/Blue () White/Yellow () White/Green () Yellow () Drain -ACABLE D -ACABLE E -ACABLE F Publication -TDD-EN-P -January

Bulletin 1492 Programmable Controller Wiring Systems Overview. Digital Interface Modules (IFMs) Feed-Through

Bulletin 1492 Programmable Controller Wiring Systems Overview. Digital Interface Modules (IFMs) Feed-Through Bulletin Overview Digital Interface Modules (IFMs) Feed-Through Feed-through IFMs provided the same capability as normal terminal blocks, but in a more condensed package. Feed-through Standard For -point:

More information

A-B Compatible Interface Modules. Connect with CAGE CLAMP

A-B Compatible Interface Modules. Connect with CAGE CLAMP AB Compatible Interface Modules Connect with CAGE CLAMP Interface Modules for AllenBradley PLC Platforms Connect with CAGE CLAMP Wiring systems for PLC I/O cards have been reducing wiring time, eliminating

More information

Order No. of the options EMC filter Class A

Order No. of the options EMC filter Class A Ordering Data for Variant Dependent Options The options listed here (filters, chokes, brake resistors, gland plates, fuses and circuit breakers) are inverter specific. The inverter and the associated options

More information

M A C H I N E V I S I O N C A B L E S

M A C H I N E V I S I O N C A B L E S K N I L C A M E R A L I N K M A C H I N E V I S I O N C A B L E S C A M E R A Select Connector Type: End 1 MDR Male = 1 MDR Female = 2 MDR Male Low rofile R/A Exit U = 3 MDR Male Low rofile R/A Exit DWN

More information

Data sheet Connection line M12 plug straight - RJ45 plug straight 8-pole, X-coded 5.0 m

Data sheet Connection line M12 plug straight - RJ45 plug straight 8-pole, X-coded 5.0 m Page 1/5 Illustrations Dimensional drawing See enlarged drawings at the end of document Product specification shielded M12-plug to RJ45-plug connection line Cat.6, 8-pole M12-connector, X-coded, straight

More information

General. Principles. 3-Trapped Key Switches. 11-Cat. No. Index. Logic. Power. Safety Switches Trapped Key Switches Overview

General. Principles. 3-Trapped Key Switches. 11-Cat. No. Index. Logic. Power. Safety Switches Trapped Key Switches Overview R Safety Trapped Key Overview Key Coding Below is an example reference guide that is useful in selecting and tracking codes. Start down the Aa column as the lower codes (typically Aa to Za) are stocked.

More information

DATE: May 19, 2000 Service Instruction No. 1443E (Supersedes Service Instruction No. 1443D) Engineering Aspects are FAA Approved

DATE: May 19, 2000 Service Instruction No. 1443E (Supersedes Service Instruction No. 1443D) Engineering Aspects are FAA Approved DATE: May 19, 2000 (Supersedes Service Instruction No. 1443D) Engineering Aspects are FAA Approved SUBJECT: MODELS AFFECTED: TIME OF COMPLIANCE: Approved Slick Magnetos on Textron Lycoming Engines See

More information

2 Finger, 3 Finger, 4 Finger Parallel Style Air Gripper. Series MHS. MHZ MHF MHL MHR MHK MHS MHC MHT MHY MHW MRHQ Misc.

2 Finger, 3 Finger, 4 Finger Parallel Style Air Gripper. Series MHS. MHZ MHF MHL MHR MHK MHS MHC MHT MHY MHW MRHQ Misc. 1 inger, inger, inger arallel Style Air Gripper Series MH MH - --1 ightweight, compact design with reduced height ong stroke () introduced to upgraded series. Ideal for gripping workpieces of different

More information

XTRA GUARD 4 MULTIPAIR, SUPRASHIELD EXTRA-PROTECTION, HIGH/LOW TEMPERATURE TPE JACKET

XTRA GUARD 4 MULTIPAIR, SUPRASHIELD EXTRA-PROTECTION, HIGH/LOW TEMPERATURE TPE JACKET XTRA GUARD 4 MULTIPAIR, SUPRASHIELD EXTRA-PROTECTION, HIGH/LOW TEMPERATURE TPE JACKET UL TYPE PLTC UL AWM STYLE 20237 CSA AWM IA/B IIA/B FT1 76 CHOOSE XTRA GUARD 4 FOR: Three Times the Low-Temperature

More information

Technical data sheet LÜTZE SUPERFLEX PLUS (C) PUR FEEDBACK Encoder cables for Siemens and other systems For highest requirements in drive technology

Technical data sheet LÜTZE SUPERFLEX PLUS (C) PUR FEEDBACK Encoder cables for Siemens and other systems For highest requirements in drive technology PUR feedback cables C-track compatible Subject to technical modification 111456 Identification Type SU+(C)P SE(4 0,5+4 2 0,38)UL 30V GN SIEMENS designation* 1BD21 Use/Application/Characteristics Application

More information

7. Are you upgrading a complete engine from a TCM/ Bendix to a Slick system? If yes, purchase a complete Slick Ignition Upgrade Kit.

7. Are you upgrading a complete engine from a TCM/ Bendix to a Slick system? If yes, purchase a complete Slick Ignition Upgrade Kit. 1.1 PRODUCT APPLICATION INFORMATION WORKSEET The following information will aid you in selecting the correct magneto, upgrade kit, or ignition harness: 1. Engine Manufacturer 2. Engine Model Number 3.

More information

Series MHSH3. ø16, ø20, ø25, ø32, ø40, ø50, ø63, ø80 Through Hole. How to Order. Dust cover type (with dust cover only)

Series MHSH3. ø16, ø20, ø25, ø32, ø40, ø50, ø63, ø80 Through Hole. How to Order. Dust cover type (with dust cover only) inger Air Gripper arallel Type Series MHSH ø1, ø, ø, ø, ø, ø, ø, ø Through Hole MHSH How to Order D N Dust cover Nil Without dust cover J With dust cover Note) ø1, ø and ø are not available with dust cover.

More information

DataTwist. Cables. DataTwist 600 I-STP - Belden 1888NH. Description

DataTwist. Cables. DataTwist 600 I-STP - Belden 1888NH. Description DataTwist Cables DataTwist 600 I-STP -Belden NH DataTwist 300 I-STP -Belden 66A/970A / Belden 66NH/70NH DataTwist FTP -Belden 730A / Belden 730 NH DataTwist STP -Belden 73A / Belden 73NH DataTwist 5 FTP

More information

IEC Power Control SIRIUS. Motor Starter Protectors. Revised 04/20/15. Section Overview... 1/2-1/3. Motor Starter Protectors

IEC Power Control SIRIUS. Motor Starter Protectors. Revised 04/20/15. Section Overview... 1/2-1/3. Motor Starter Protectors 04/20/15 IEC Power Control Motor Starter Protectors Contents Pages Section Overview......................... 1/2-1/3 Motor Starter Protectors 3RV20 MSP, Class 10/20.................... 1/4-1/5 3RV10 MSP,

More information

Motor Starter Protectors

Motor Starter Protectors Motor Starter Protectors Industrial Controls Product Catalog 207 Section contents Section Overview /2 - /3 Motor Starter Protectors 3RV20 MSP, Class 0/20 /4 - /5 Circuit Breakers 3RV27, 3RV28 Circuit Breaker

More information

Motor Starter Protectors

Motor Starter Protectors Motor Starter Protectors Industrial Controls Product Catalog 09 Section contents Section Overview / - /3 Motor Starter Protectors 3RV0 MSP, Class 0/0 /4 - / Circuit Breakers 3RV7, 3RV8 Circuit Breaker

More information

Overhaul and repair procedures for the following Standard Cast Cylinder Stud Assemblies and Cylinder Valve Assemblies:

Overhaul and repair procedures for the following Standard Cast Cylinder Stud Assemblies and Cylinder Valve Assemblies: Technical Aspects are FAA Approved Number: L00-13 C Replace L00-13 B Date: 04/29/2005 Subject: Overhaul and repair procedures for the following Standard Cast Cylinder Stud Assemblies and Cylinder Valve

More information

Selection Guide. PowerFlex Digital DC Drive

Selection Guide. PowerFlex Digital DC Drive Selection Guide PowerFlex Digital DC Drive PowerFlex Digital DC Drive The PowerFlex DC drive combines powerful performance with flexible control to produce a highly functional, cost effective drive and

More information

DIGITAX ST UNIMOTOR 2000RPM COMBINATIONS

DIGITAX ST UNIMOTOR 2000RPM COMBINATIONS DIGITAX ST UNIMOTOR FM @ 2000RPM COMBINATIONS Table data based on 2000 rpm motors 3x Torque Part Part DST1201 0.72 1.0 2.16 2.9 0.12 055E2A300 DST1201 1.2 0.9 3.6 2.6 0.7 075E2A200 DST1201 1.4 1.7 4.2

More information

Transmission in Limp Home Mode (S- B-27.00/102b, December 16, 2008)

Transmission in Limp Home Mode (S- B-27.00/102b, December 16, 2008) Transmission in Limp Home Mode (S- B-27.00/102b, December 16, 2008) Topic number Version 1 Function group LI27.00-P-045638 27.00 General Date 01-19-2009 Validity Reason for change All Models Equipped with

More information

G3 UNIVERSAL GRIP CONFIGURATION GUIDE

G3 UNIVERSAL GRIP CONFIGURATION GUIDE G3 UNIVERSAL GRIP CONFIGURATION GUIDE www.ottoexcellence.com Industrial Grips for Demanding Applications OTTO serves agriculture, construction, off-highway, material handling and specialized industrial

More information

Data sheet. Connection cable M12 jack straight - free line end 8-pole, X-coded 0.5 m. Illustrations P/N 142M2X20005 EAN

Data sheet. Connection cable M12 jack straight - free line end 8-pole, X-coded 0.5 m. Illustrations P/N 142M2X20005 EAN Page 1/6 Illustrations Dimensional drawing Cut-out See enlarged drawings at the end of document Product specification shielded M12 Ethernet connection cable Cat.6A, x-coded, 8-pole side 1: M12-jack, straight

More information

MOONEY INTERNATIONAL CORPORATION The Symbol of Performancet MOONEY SPECIAL LETTER Date:

MOONEY INTERNATIONAL CORPORATION The Symbol of Performancet MOONEY SPECIAL LETTER Date: MOONEY INTERNATIONAL CORPORATION The Symbol of Performancet MOONEY SPECIAL LETTER 15-24 Date: 11-19-2015 SUBJECT: MODELS/ S/N AFFECTED: To ADVISE MOONEY OWNERS/OPERATORS of the LYCOMING Service Instruction

More information

50A Dual-Feed 5/5 GMT Total Front Access Fuse Panel

50A Dual-Feed 5/5 GMT Total Front Access Fuse Panel 50A Dual-Feed 5/5 GMT Total Front Access Fuse Panel Power :: GMT05FA User Manual Applys to : GMT05FA Table of Contents 1.1 Overview...3 1.2 Rack-mounting Considerations...4 1.3 Specifications...4 1.4 Installation...6

More information

SSR SSR SSR SSR

SSR SSR SSR SSR DMX 52 Page DMX52 decoder firing board module 20 VAC reference Input 2 3 4 The Thyristor Firing board is compatible withdmx52 control standard 4 DMX52 triggers 2 3 4 - +- +- +- + The can trigger control

More information

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory

More information

Audio System - Whining/Buzzing Noise From Speakers

Audio System - Whining/Buzzing Noise From Speakers Audio System - Whining/Buzzing Noise From Speakers Article No. 02-16-4 08/19/02 ^ FUEL SYSTEM - FUEL PUMP "WHINING"/"BUZZING" NOISE COMES THROUGH ENTERTAINMENT OR TWO-WAY RADIO SPEAKER ^ RADIO - ENTERTAINMENT

More information

DART. Operation / Installation Manual. Digital Analog Remote Transducer. Computer Weld Technology, Inc. Manual Part Number: A8M5015 Revised: 9/28/2004

DART. Operation / Installation Manual. Digital Analog Remote Transducer. Computer Weld Technology, Inc. Manual Part Number: A8M5015 Revised: 9/28/2004 Computer Weld Technology, Inc. 10702 Old Bammel N Houston Rd. Houston, TX 77086 Phone: (713) 462-2118 Fax: (713) 462-2503 Email: cwt@cweldtech.com DART Digital Analog Remote Transducer Operation / Installation

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

Ø 68 mm to ø 115 mm. Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating:

Ø 68 mm to ø 115 mm. Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: , EN 60079 Electrical Specifications Code: Incremental Resolution: Up to 10,000 ppr (pulses per revolution) Supply Voltage: ** 4.5 Vdc min. to 30 Vdc max. (45 ma max. - no load) Low: 500 mv max. at 10

More information

Industrial Controls. Load Feeders. Configuring the SIRIUS Modular System Selection data for Fuseless and Fused Load Feeders. Configuration Manual

Industrial Controls. Load Feeders. Configuring the SIRIUS Modular System Selection data for Fuseless and Fused Load Feeders. Configuration Manual Configuration Manual ndustrial Controls Load Feeders Configuring the SRUS Modular System Selection data for Fuseless and Fused Load Feeders Edition 09/2017 siemens.com ntroduction 1 General information

More information

Terminal Blocks/Wiring Systems/Signal Conditioners Table of Contents

Terminal Blocks/Wiring Systems/Signal Conditioners Table of Contents Terminal Blocks/Wiring Systems/Signal Conditioners Table of Contents IEC Accessories and Technical Specifications DIN Mounting Rails Page - End Barriers Page - End Anchors/Retainers Page - Partition Plates

More information

2012 FIAT 500 CM6000 INSTALL

2012 FIAT 500 CM6000 INSTALL Page1 1. Digital Multi-Meter 2. Crimpers 3. Soldering Iron and Solder 4. Drill 5. Sockets 6. Torx s 7. CM6000 8. Spare Key for Key Wrap TOOLS AND PARTS ANALOG INTERFACE FUNCTION COLOR LOCATION POLARITY

More information

Kinetix 300 Single-axis Servo Drives

Kinetix 300 Single-axis Servo Drives Installation Instructions Kinetix 300 Single-axis Servo Drives Catalog Numbers 2097-V31PR0, 2097-V31PR2, 2097-V32PR0, 2097-V32PR2, 2097-V32PR4, 2097-V33PR1, 2097-V33PR3, 2097-V33PR5, 2097-V33PR6, 2097-V34PR3,

More information

VACUUM PRESSURE PUMPS INSTALLATION CAUTIONS AND INFORMATION READ AND FOLLOW CAREFULLY!

VACUUM PRESSURE PUMPS INSTALLATION CAUTIONS AND INFORMATION READ AND FOLLOW CAREFULLY! F.A.A.-P.M.A. MODEL 1U128A AND 1U128B REVISION 17 February 21, 2002 VACUUM PRESSURE PUMPS INSTALLATION CAUTIONS AND INFORMATION READ AND FOLLOW CAREFULLY! The following information applies to all installations

More information

PowerFlex Digital DC Drive

PowerFlex Digital DC Drive Technical Data PowerFlex Digital DC Drive Table of Contents Topic Page Additional Resources 3 Product Description 3 Standard Drives Program 4 Catalog Number Explanation 6 Standard Drives Product Selection

More information

Engineering Data Book

Engineering Data Book 40VMH High Static Duct Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without

More information

Part Number: 10GX F/UTP CMR PATCH CORDS 10GX F/UTP CMR Patch Cords

Part Number: 10GX F/UTP CMR PATCH CORDS 10GX F/UTP CMR Patch Cords Part Number: 10GX F/UTP CMR PATCH CORDS 10GX F/UTP CMR Patch Cords Product Description 10GX F/UTP CMR Patch Cords Technical Specifications Product Overview Environmental Space: Suitable Applications: Riser

More information

CONTINENTAL TOWN CAR NAVIGATOR 2002 BLACKWOOD

CONTINENTAL TOWN CAR NAVIGATOR 2002 BLACKWOOD FUEL SYSTEM FUEL PUMP Article No. WHINING / BUZZING NOISE COMES THROUGH 02-16-4 ENTERTAINMENT OR TWO-WAY RADIO SPEAKER RADIO ENTERTAINMENT OR TWO-WAY COMMUNICATION WHINING / BUZZING NOISE IN SPEAKERS CAUSED

More information

micromaster Catalog DA MICROMASTER 410/420/430/440 Inverters 0.12 kw to 250 kw

micromaster   Catalog DA MICROMASTER 410/420/430/440 Inverters 0.12 kw to 250 kw micromaster Catalog DA 51.2 2002 MICROMASTER 410/420/430/440 Inverters 0.12 kw to 250 kw Catalogs of the Business Unit Standard Drives MICROMASTER 410/420/430/440 Inverters DA 51.2 Order No.: German: E86060-K5151-A121-A3

More information

EPRO AUTOMOTIVE INDUSTRY (JIANGSU) CO.,LTD

EPRO AUTOMOTIVE INDUSTRY (JIANGSU) CO.,LTD 16-FB00-01D2 HEADLAMP D & MOTOR 6Y1941016 / 6Y1941016C 6Y1941015 / 6Y1941015C 16-FB00-01B2 HEADLAMP E - AFS 6Y1941016F / 6Y1941016P 6Y1941015F / 6Y1941015P 16-FB00-05 16-FB00-05B2 6Y0941700A 6Y0941699A

More information

Page No. 1 of 6 Date: April 29, 2011 Installation Eligibility: Model. PMA NUMBER PQ2724CE Part No. Model No.

Page No. 1 of 6 Date: April 29, 2011 Installation Eligibility: Model. PMA NUMBER PQ2724CE Part No. Model No. PMA NUMBER No. FAA Approval Basis and Approved Design Data Eligibility: Make Page No. 1 of 6 Propeller ATG210760 Woodward G210760 P210452( ), 210685, Test Report and Alexandria 17-30, 17-30A (IO-520 only)

More information

SERVICE INSTRUCTION. 652 Oliver Street Williamsport, PA U.S.A. Tel Fax

SERVICE INSTRUCTION. 652 Oliver Street Williamsport, PA U.S.A. Tel Fax 652 Oliver Street Williamsport, PA. 17701 U.S.A. Tel. 570 323 6181 Fax. 570 327 7101 www.lycoming.com SERVICE INSTRUCTION DATE: March 8, 2012 Service Instruction No. 1098H (Supersedes Service Instruction

More information

NEMA Premium Efficiency Motors SIE series

NEMA Premium Efficiency Motors SIE series NEMA Premium Efficiency Motors IE series NEMA Premium 2015 Product Catalogue MOTEUR 'PREMIUM EFFICIENCY' CERTIFIÉ ET VERIFIÉ CA (UA) BATI EN FONTE ERVICE FACTOR JUQU'À 1.40 IOLATION DE CLAE F (155 C),

More information

3VF3 to 3VF8 Circuit-Breakers

3VF3 to 3VF8 Circuit-Breakers 3VF3 to 3VF8 Circuit-Breakers Accessories Operating mechanisms For other s for 3VF3 with knob Rotary drive, complete, scope of supply Cubicle door for 3VF6 Motor operating mechanism for 3VF3 Motor operating

More information

LANmark-1000 Category 6 Plenum

LANmark-1000 Category 6 Plenum LANmark-1000 is an ANSI/TIA/EIA Category 6 verified cable that is ideal for gigabit network applications. It introduces new electrical performance parameters which are needed for gigabit Ethernet network

More information

Crankshaft Gear Retaining Bolt Replacement NOTE

Crankshaft Gear Retaining Bolt Replacement NOTE 652 Oliver Street Williamsport, PA 17701 U.S.A. Tel. 570-323-6181 Fax. 570-327-7101 www.lycoming.textron.com MANDATORY SERVICE BULLETIN DATE: September 30, 2002 Engineering Aspects of this Service Bulletin

More information

Original parts TRi / 280 / Factory R

Original parts TRi / 280 / Factory R Original parts TRi 0 / 0 / Factory R Contents: page: Cycle part: Part : Frame Part : Steering Part : Front wheel Part : Swing arm Part : Rear wheel 0 Part : Plastics Part : Admission Part : Cooler Part

More information

AS/ASH SERIES ALUMINUM PNEUMATIC AND HYDRAULIC CYLINDERS... 6

AS/ASH SERIES ALUMINUM PNEUMATIC AND HYDRAULIC CYLINDERS... 6 AS/ASH SERIES ALUMINUM PNEUMATIC AND HYDRAULIC CYLINDERS............. 6 Section 6 8 ORDERING INFORMATION For Rod End Dimensions see back cover foldout... Basic Cylinder No Mount.0" to 4.00" For pressure

More information

Hook-Up Wire Alpha Wire ALPHA 373

Hook-Up Wire Alpha Wire ALPHA 373 Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 373 The broad range of hookup wire from Alpha means you will find the product exactly suited to

More information

Series MHSL3. How to Order F9N. Auto switch type. Nil Without auto switch (bulit-in magnet) Auto switch specifications. Type. Solid state.

Series MHSL3. How to Order F9N. Auto switch type. Nil Without auto switch (bulit-in magnet) Auto switch specifications. Type. Solid state. inger Air ripper arallel Type Cylinder Bore Size ø1 to ø Series MS ø1, ø, ø, ø, ø, ø, ø, ø, ø1, ø1 MS ow to Order D N finger MS finger MS Cylinder Bore Size ø to ø1 Symbol Number of fingers fingers Number

More information

Kinetix 350 Single-axis EtherNet/IP Servo Drives

Kinetix 350 Single-axis EtherNet/IP Servo Drives Installation Instructions Kinetix 350 Single-axis EtherNet/IP Servo Drives Catalog Numbers 2097-V31PR0-LM, 2097-V31PR2-LM, 2097-V32PR0-LM, 2097-V32PR2-LM, 2097-V32PR4-LM, 2097-V33PR1-LM, 2097-V33PR3-LM,

More information

CENTERLINE 2100 Motor Control Centers

CENTERLINE 2100 Motor Control Centers TECHNICAL DATA CENTERLINE 2 Motor Control Centers Instantaneous Trip Motor Circuit Protectors (MCP) in Combination NEMA Starter, Soft Starter (SMC) and Variable Frequency AC Drive Units 1A Frame Instantaneous

More information

!Linear & Rotary Positioning Stages. !Servo Motors & Drives. !Gearmotors & Gearheads. GM Series Stealth Planetary Gearmotor Product Manual

!Linear & Rotary Positioning Stages. !Servo Motors & Drives. !Gearmotors & Gearheads. GM Series Stealth Planetary Gearmotor Product Manual !Linear & Rotary Positioning Stages!Servo Motors & Drives!Gearmotors & Gearheads GM Series Stealth Planetary Gearmotor Product Manual GM Series Stealth Planetary Gearmotor Product Manual Rev: 7.0 / 0305

More information

Engineering Data Book

Engineering Data Book 40VMA Outside Air Processing Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without

More information

SERVICE INSTRUCTION. All Certified Lycoming direct drive engines. TIME OF COMPLIANCE: At owner s discretion.

SERVICE INSTRUCTION. All Certified Lycoming direct drive engines. TIME OF COMPLIANCE: At owner s discretion. 652 Oliver Street Williamsport, PA. 17701 U.S.A. Telephone +1 (800) 258-3279 U.S. and Canada (Toll Free) Telephone +1 (570) 323-6181 (Direct) Facsimile +1 (570) 327-7101 Email Technicalsupport@lycoming.com

More information

Boiler Assembly 1:20.3 Large Scale 38 Ton Two-Truck Shay

Boiler Assembly 1:20.3 Large Scale 38 Ton Two-Truck Shay 00R02 00N05 00X04 00V02 0ZV05 AT025 00P01 G113-0ZB03 88082-00R02 00B01 00Y03 00Q06 00X07 G812X- MT011 00238 G811X 0ZV04 MT084 0ZT04 MT023 00Z03 00N07 0ZA03 MTZ10 00S08 00C01 00Y06 G113X- 00Q01 00H01 MT076

More information

General Principles 9-3-Trapped Key. Switches. 11-Cat. No. Index. Logic Power Stainless steel construction.

General Principles 9-3-Trapped Key. Switches. 11-Cat. No. Index. Logic Power Stainless steel construction. Safety Trapped Key N precision cut keys Interlocking and ontrol Solutions Trapped Key Interlocks Why Use Them? Based upon the premise that no one key can be in two places at once, key interlock systems

More information

ORIGINAL PARTS TRi 2014

ORIGINAL PARTS TRi 2014 ORIGINAL PARTS TRi 204 CONTENTS PAGE Cycle part: Part : Frame 2 Part 2: Steering 4 Part 3: Front wheel 6 Part 4: Swing arm 8 Part 5: Rear wheel 0 Part 6: Plastics 2 Part 7: Admission 4 Part 8: Cooler 6

More information

Contents. Cable assemblies, Model 10.

Contents. Cable assemblies, Model 10. Contents Cable assemblies, Model 10...33 Flying leads, Pigtails A11 Cable assemblies, Model 10 Main Characteristics Choice of connectors to interface with various sensor Choice of cable to suit various

More information

Parallel Type Air Gripper/2 Finger, 3 Finger, 4 Finger

Parallel Type Air Gripper/2 Finger, 3 Finger, 4 Finger Parallel Type Air Gripper/ inger, inger, inger MHS Series ø1, ø, ø, ø, ø, ø, ø, ø, ø1, ø MHZ MH MH MHR MHK MHS MHC MHT MHY MHW -X MRHQ MA D- ightweight, compact design with reduced height High repeatability:

More information

List of system parts and belonging Descriptive Documents

List of system parts and belonging Descriptive Documents DeltaV Scalable Process System includes the following system parts: Item Model Name Type Technical Data 1. KL1601X1-BA1 I/O Port (IOP) 2. KL2101X1-BA1 CHARM I/O Card (CIOC) 3. KL2102X1-BA1 Wireless I/O

More information

CERTIFICATE OF COMPLIANCE

CERTIFICATE OF COMPLIANCE FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 02062 USA T: 781 762 4300 F: 781-762-9375 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL

More information

Overload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview

Overload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors.

More information

Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures.

Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures. ENGINEERING COMPANY INC. 51 Winthrop Road Chester, Connecticut 06412-0684 Phone: (860) 526-9504 Fax: (860) 526-4078 Internet: www.whelen.com Sales e-mail: autosale@whelen.com Canadian Sales e-mail: autocan@whelen.com

More information

PRODUCT PROFILE VARIABLE-DEPTH, FLANGE- MOUNTED DISCONNECT SWITCHES A BULLETIN 1494V

PRODUCT PROFILE VARIABLE-DEPTH, FLANGE- MOUNTED DISCONNECT SWITCHES A BULLETIN 1494V PRODUCT PROFILE BULLETIN 1494V Rockwell Automation introduces the enhanced version of Allen-Bradley Bulletin 1494V Variable-Depth, Flange-Mounted Switches that meet industrial requirements for dependable

More information

Inverter MICROMASTER 440

Inverter MICROMASTER 440 Inverter MICROMASTER 0 /2 Description / Circuit diagrams /6 Technical data /9 Selection and ordering data /12 Options /2 Dimension drawings Siemens DA 51.2 2003/200 /1 MICROMASTER 0 Description Applications

More information

SENTRON VL Series Product Specifications

SENTRON VL Series Product Specifications SENTRON VL Series Product Specifications VL 400 Frame 400 s Electronic Releases ETU TRIP RELEASE 315 12-315 3VL4731 - A 3-0AA0 400-400 3VL4740 - A 3-0AA0 3 = 3 poles All VL400 circuit-breakers are shipped

More information

Technical Data. PowerFlex 700H Adjustable Frequency AC Drive

Technical Data. PowerFlex 700H Adjustable Frequency AC Drive Technical Data PowerFlex 700H Adjustable Frequency AC Drive Table of Contents Topic Page Product Overview.............................................. 3 Key Features and Benefits.......................................

More information

CERTIFICATE OF COMPLIANCE

CERTIFICATE OF COMPLIANCE FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 02062 USA T: 781 762 4300 F: 781-762-9375 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL

More information

NEMA Premium. Efficiency Motors SIE series EISA Product Catalogue

NEMA Premium. Efficiency Motors SIE series EISA Product Catalogue NEMA Premium Efficiency Motors IE series NEMA Premium EIA 2007 Product Catalogue NEMA Premium Motors IE series ENERGY LEGILATION UMMARY The previous legislation affecting the energy efficiency of motors

More information

1395 Digital DC Drive Renewal Parts

1395 Digital DC Drive Renewal Parts Important Information, Read First 1395 Digital DC Drive Page 1 of 19 The 1395 Product Line has evolved from current rated units to horsepower rated units. Within the range of sizes there are various series

More information

Original parts TR280i 2013

Original parts TR280i 2013 Original parts TR0i 0 Contents: page: Cycle part: Part : Frame Part : Steering Part : Front wheel Part : Swing arm Part : Rear wheel 0 Part : Plastics Part : Admission Part : Cooler Part : Exhaust Motor

More information

Parallel Style Air Gripper/2 Finger, 3 Finger, 4 Finger

Parallel Style Air Gripper/2 Finger, 3 Finger, 4 Finger arallel Style Air Gripper/ inger, inger, inger Series ø1, ø, ø, ø, ø, ø, ø, ø, ø1, ø MHZ MH MH Courtesy of Steven Engineering, Inc.- Ryan Way, South San rancisco, CA --Main Office: () --Outside ocal Area:

More information

REAR WHEEL DRIVE DAMAGED CIRCUIT/LOCATION CODES

REAR WHEEL DRIVE DAMAGED CIRCUIT/LOCATION CODES REAR WHEEL DRIVE DAMAGED CIRCUIT/LOCATION CODES BODY AND REAR END LIGHTING 08-91- Exterior Lighting LA Back-Up, License Lamps LD Park, S/Marker, Tail, Opera Lamps LH Stop Lamp, Hazard Flasher LJ Turn Signal

More information

Data sheet CFBUS.PVC PVC - e-chain - Bus cable for medium load requirements (class 4.3.2): shielded, oil-resistant as well as flame-retardant.

Data sheet CFBUS.PVC PVC - e-chain - Bus cable for medium load requirements (class 4.3.2): shielded, oil-resistant as well as flame-retardant. Overview Bus system Profibus CAN-Bus / Feldbus CC-Link Part. No..001.021 &.022.035 Example drawing Bus system Part. No. Ethernet (CAT5 / CAT5e / GigE / PoE).040,.045 &.049 Ethernet (CAT6 A / PoE).050 FireWire

More information

Terminal Blocks/Wiring Systems/Signal Conditioners Table of Contents

Terminal Blocks/Wiring Systems/Signal Conditioners Table of Contents Terminal Blocks/Wiring Systems/Signal Conditioners Table of Contents IEC Accessories and Technical Specifications DIN Mounting Rails Page - End Barriers Page - End Anchors/Retainers Page - Partition Plates

More information

Data sheet E-DAT modul 24x8(8) 1RU patch panel Cat.6A, light gray

Data sheet E-DAT modul 24x8(8) 1RU patch panel Cat.6A, light gray Page 1/7 Illustrations Dimensional drawing Wiring See enlarged drawings at the end of document Product specification 19 inch 1RU module frame with 24 individual "E-DAT modul" modules component testing

More information

Kinetix VP Low Inertia Servo Motors with mm Frame Size

Kinetix VP Low Inertia Servo Motors with mm Frame Size Installation Instructions Original Instructions Kinetix VP Low Inertia Servo s with 063 165 mm Frame Size Catalog Numbers VPL-A0631, VPL-A0632, VPL-A0633, VPL-A0751, VPL-A0752, VPL-A0753, VPL-A1001, VPL-A1002,

More information

Type 2REX-A. Oil & Gas / Heavy Industry

Type 2REX-A. Oil & Gas / Heavy Industry Oil & Gas / Heavy Industry Type 2REX-A EN 60079 Electrical Specifications Code: Incremental Resolution: 1 to 10,000 ppr (pulses per revolution) Supply Voltage: ** 4.5 Vdc min. to 30 Vdc max. (45 ma max.

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

FKHS Series. 3 Jaw Parallel Motion Pneumatic Grippers. Mounting Hole. Sensor Capable. Bottom tapped holes. Dowel Hole & Slot

FKHS Series. 3 Jaw Parallel Motion Pneumatic Grippers. Mounting Hole. Sensor Capable. Bottom tapped holes. Dowel Hole & Slot Catalog No. KHS- KHS Series Jaw Parallel Motion Pneumatic Grippers Mounting Hole Can be mounted from the gripper side Mounting slot for easy sensor installation Sensor Capable Bottom tapped holes Can be

More information

Bulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents

Bulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents Bulletin IEC Non-Reversing Starters Product Overview/Product Selection Cat. No. -CABAF--R-P IP (Type ) Metal Enclosure with Lift-off Cover Bulletin IEC Non-Reversing Starters Impact-resistant molded enclosures

More information

Data sheet E-DAT Industry patch cord V6 IP67 - RJ m

Data sheet E-DAT Industry patch cord V6 IP67 - RJ m Illustrations Dimensional drawing Page 1/6 See enlarged drawings at the end of document Product specification fully shielded Cat.6 patch cable AWG 26/7 S/FTP with PUR cable sheath 1 x RJ45 and 1 x RJ45-IP67-V6

More information

Engineering Data Book

Engineering Data Book 40VMM Medium Static Duct Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without

More information

Cable-Operated Disconnect Switches. Accessories

Cable-Operated Disconnect Switches. Accessories Cable-Operated Disconnect Switches Accessories Description For Use With Auxiliary Contacts 1 N.O. Contact 1494C, 1494F, 1494V, and 1494G ( 1495-N8 1 N.O. Contact (low-level switching) A) Disconnect Switches

More information

Parallel Style Air Gripper/2 Finger, 3 Finger, 4 Finger

Parallel Style Air Gripper/2 Finger, 3 Finger, 4 Finger arallel Style Air Gripper/ inger, inger, inger Series MHS ø1, ø, ø, ø, ø, ø, ø, ø, ø1, ø MHZ MH MH MHR MHK MHS MHC MHT MHY MHW -X MRHQ MA D- ightweight, compact design with reduced height High repeatability:

More information

Installation Instructions

Installation Instructions Installation Instructions (Cat. No. 1794-ASB Series B) 1 9 2 3 4, 5 6 7 8 Component Identification 1 Remote I/O Adapter module 2 Indicators 3 Communication reset pushbutton (PRL) 4 Access door to switches

More information

Ordering Information. Application Example. New General-purpose Incremental-type. Rotary Encoder. Accessories (Order Separately)

Ordering Information. Application Example. New General-purpose Incremental-type. Rotary Encoder. Accessories (Order Separately) Rotary Encoder New General-purpose Incremental-type Rotary Encoder A wide operating voltage range of 5 to 24 VDC (open collector model). Resolution of 2,000 pulses/revolution in 40-mm housing. can be adjusted

More information

Voltage Configuration Information

Voltage Configuration Information Setting the instrument power configuration There are seven possible line voltage power configurations for the 6890 GC. Voltage ( 10%, +5%) Table 1230-1 Frequency (Hz) Voltage Configuration Information

More information

Part No Rev. E

Part No Rev. E l T e m p o s o n i c s P o s i t i o n S e n s o r s a n d S y s t e m s Part No. 550033 Rev. E T emposonics II Position Sensors Installation & Instruction Manual 11-98 550055 Revision E GENERAL INFORMATION

More information

Ø 68 mm to ø 115 mm. Material: Weight: Shaft Loads: Enclosure Rating: Connection Options. Cable: Cable Glands:

Ø 68 mm to ø 115 mm. Material: Weight: Shaft Loads: Enclosure Rating: Connection Options. Cable: Cable Glands: Electrical Specifications Code: Incremental Resolution: Up to 10,000 ppr (pulses per revolution) Supply Voltage: ** 4.5 Vdc min. to 30 Vdc max. (45 ma max. - no load) Low: 500 mv max. at 10 ma Voltage:

More information

27Overload Relays. Overview Combinations of overload relays and contactors SIRIUS 3R. Thermally delayed overload relays CLASS 10

27Overload Relays. Overview Combinations of overload relays and contactors SIRIUS 3R. Thermally delayed overload relays CLASS 10 27Overload Relays Overview Combinations of overload relays and contactors SIRIUS 3R 27Overload Relays Contactors Current range A 3RT10 1 Size S00 3/4/5.5 kw 3RT10 2 Size S0 5.5/7.5/11 kw 3RT10 3 Size S2

More information

Inverter MICROMASTER 440

Inverter MICROMASTER 440 Inverter MICROMASTER 0 /2 Description / Circuit diagrams /6 Technical data /9 Selection and ordering data /12 Options /26 Dimension drawings Siemens DA 51.2 2007/2008 /1 MICROMASTER 0 Siemens AG 2007 Description

More information

General Principles 9-3-Trapped Key. Switches. 11-Cat. No. Index. Logic Power Stainless steel construction.

General Principles 9-3-Trapped Key. Switches. 11-Cat. No. Index. Logic Power Stainless steel construction. Safety Trapped Key General Principles 9-3-Trapped Key N precision cut keys Interlocking and ontrol Solutions Trapped Key Interlocks Why Use Them? Based upon the premise that no one key can be in two places

More information

Printed from Summit Aviation's Computerized Aviation Reference Library, 4/26/2000 Page 1

Printed from Summit Aviation's Computerized Aviation Reference Library, 4/26/2000 Page 1 98-17-11 Textron Lycoming and Teledyne Continental Motors: Amendment 39-10713. Docket 98-ANE-27-AD. {As corrected at 63 FR 55918 - Ed.} {New-98-10} Textron Lycoming (LYC) O-235, O-235-C1, O-235-C2C, O-235-L2C,

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

1260 Infinity II Degasser User Manual. 5 Maintenance

1260 Infinity II Degasser User Manual. 5 Maintenance 1260 Infinity II Degasser User Manual 5 Maintenance Warnings and Cautions 40 Simple Repairs - Maintenance 42 Clean the Instrument 43 Assemble the Main Cover 44 Check and Change the Power Fuses 45 This

More information

Page 1 of 6. DirectWire Vehicle Information 2015 Land Rover Range Rover Sport - North America. Wiring Information. Page 1 of 6

Page 1 of 6. DirectWire Vehicle Information 2015 Land Rover Range Rover Sport - North America. Wiring Information. Page 1 of 6 Page 1 of 6 Wiring Information 12 Volts Green (60A) + Passenger Dash Fuse pin 22 Ground (chassis ground) Starter Blue/White + Passenger Dash Fuse plug, pin 18 Ignition Accessory Yellow or Orange (for ignition

More information

NICHIGOH S CABLE CONTENTS ROBOT CABLE CONTROL CABLE RO-FLEX RO-FLEX RCVV-S 9 VCT-F 11 VCTF 13 MVVS 15 DATA TRANSMISSION CABLE NFKVV-SB 18

NICHIGOH S CABLE CONTENTS ROBOT CABLE CONTROL CABLE RO-FLEX RO-FLEX RCVV-S 9 VCT-F 11 VCTF 13 MVVS 15 DATA TRANSMISSION CABLE NFKVV-SB 18 0 NICHIGOH S CABLE CONTENTS ROBOT CABLE RO-FLEX3000 2 RO-FLEX3300 5 RCVV-S 9 CONTROL CABLE VCT-F 11 VCTF 13 MVVS 15 DATA TRANSMISSION CABLE NFKVV-SB 18 1 WORLD WIDE STANDARD CABLE RECOGNITION SERIES RO-FLEX3000F

More information